GPS Multiparameter Meters 7 - Hanna Instruments (Thailand)

HI9829
7
GPS Multiparameter
Meters
pH/ORP/ISE, EC/TDS/
Resistivity/Salinity/Seawater ı,
Turbidity, DO, Temperature and
Atmospheric Pressure
Multiparameter
• Logging
· Logging from probe or meter
• Fast Tracker
· Tag Identification System
• Sensor Check™
· Auto-recognition of all sensors
• GLP features
· Meets Good Laboratory Practices
• Connectivity
· PC compatible via USB
• Help feature
· On-screen user guides
• Backlight
· Backlit, graphic LCD display
portable
• Waterpoof
· Waterproof casing
7.22
| www.hannainst.com
Waterproof Protection
Auto-sensor Recognition
The meter is enclosed in an IP67 rated
waterproof casing and can withstand
immersion in water at a depth of 1 m for up
to 30 minutes. The probe features an IP68
rating for continuous immersion in water.
The probe and meter automatically
recognize the sensors that are connected.
Any ports not used on the probe will not have
the parameter displayed or be configurable.
7
Automatic Temperature
Compensation
Integrated temperature sensor
allows for automatic temperature
compensation of pH, conductivity, and
dissolved oxygen measurements.
The HI9829 features a backlit graphic LCD
with on-screen help and the capability
to display up to twelve parameters
simultaneously. The graphic display
allows for the use of virtual keys to
provide for an intuitive user interface.
Automatic Barometric Pressure
Compensation
PC Connectivity
The meter features a built-in barometer
with user-selectable units for dissolved
oxygen pressure compensation.
Logged data can be transferred to
a Windows compatible PC with the
included HI7698291 USB adapter
and HI929829 software.
Long Battery Life
The display of the meter has a battery
icon indicator to show the remaining
power. The meter is supplied with four
1.5V “C “ NiMH rechargeable batteries that
provide up to 140 hours of battery life*
Intuitive Keypad
The fitted rubber keypad has dedicated
keys for power, backlight, up/down arrows,
help and alphanumeric characters. The
meter also features two virtual soft
keys that navigate the user through the
configuration of each parameter, meter
setup, and logging of data. The interface is
intuitive for any user’s level of experience.
Trend graphing with sample date and
time stamp may be viewed on the
display or transferred to a PC.
Multiparameter
Backlit Dot Matrix LCD Display
Graphing Capability
* Without GPS or turbidity measurements
Quick Calibration
Quick Calibration provides a speedy, single
point calibration for pH, conductivity, and
dissolved oxygen. Standard calibration
options are available including pH up to
three points, conductivity at one point
and dissolved oxygen up to two points.
portable
Dedicated Help Key
Contextual help is always available through
a dedicated “HELP” key. Clear tutorial
messages and directions are available
on-screen to quickly and easily guide
users through setup and calibration. The
help information displayed is relative
to the setting/option being viewed.
GLP Data
HI9829 includes a GLP feature that
allows users to view calibration data and
calibration expiration information at the
touch of a key. Calibration data includes
date, time, buffers/standards used for
calibration, and slope characteristics.
Rugged Custom Carrying Case
Data Logging
The HI9829 allows users to store
up to 44,000 continuous or log-ondemand samples with logging intervals
from one second to three hours.
The HI9829 meter, probe, and all accessories
are supplied in a rugged carrying case
designed to provide years of use. The
inside compartment of the carrying
case is thermoformed to securely hold
and protect all of the components.
www.hannainst.com |
7.23
7
HI7698297 Quick Release Flow Cell
(optional)
Multiparameter
The HI7698297 is an optional quick release flow cell
designed for low flow sampling of environmental
groundwater. The flow cell features a threaded collar
for the HI9829 probe and two quick release fittings
for inlet and outlet flow. The HI7698297 includes a
wall mount kit for continuous monitoring option.
portable
• Field Ready
· For field calibration, our quick
calibration solution allows
standardization of pH and conductivity
with one calibration solution.
• Quick Calibration
· Simply screw the calibration beaker
filled with HI9828-25 solution onto
the probe, select “Quick calibration”
from the menu and press OK. Individual
calibration may also be performed
using multiple calibration points.
Probes
The use of Hanna’s microprocessor-based multiparameter
intelligent probes with HI9829 will provide reliable data collection
that can lead to an improved scientific understanding of the
interconnections between natural, chemical and geological
processes and manmade pollution to effectively evaluate
applications for waste discharge permits, remediate contaminated
sites and to protect or restore biological resources.
Reliable temperature measurements are a critical parameter of
aquatic system monitoring. Temperature and temperature changes
due to water releases can affect the ability of water to hold oxygen
as well as the ability of organisms to resist certain pollutants. The
intelligent probes incorporate an accurate thermistor that changes
predictably with temperature changes. Accurate temperature
reading in degrees Celsius, Fahrenheit and kelvin are displayed
and utilized by other detectors for temperature correction.
The HI76x9829 probes utilize field replaceable sensors with autorecognition. The sensors are housed with the probe electronics in a
rugged housing and a water-tight cable connection. The HI76909829
probe allows conductivity, pH/ORP (or an ISE), and dissolved oxygen
measurement. Other probe models allow turbidity and logging.
Probes with the logging function have a logging memory that
allows storage of up to 140,000 individual samples or 35,000
7.24
| www.hannainst.com
• Auto-sensor Recognition
· In this example, the HI9829 is
identifying a pH, dissolved oxygen
and EC/turbidity sensor.
complete sample data sets with date and time stamp thus
permitting up to a 70 day deployment with all channels logging
at 10 minute intervals. The probe incorporates a temperature
sensor for temperature compensation of all parameters.
The probes are available with a choice of cable lengths such as 4m,
10 m and 20 m (13’, 33’, 65’) that utilize a DIN connection to interface
with the meters. Logging probes can be connected directly to a
PC with the HI76982910 USB adapter cable, and HI929829 PC
application software to download log files directly from the probes.
Sensors
Hanna offers a selection of seven sensors to be used on the
intelligent probes. Sensor replacement is quick and easy with
screw type connectors and are color coded for easy identification.
The HI9829 automatically recognizes sensor presence.
The HI7609829-4 EC/turbidity sensor is field replaceable and
offers readings from both parameters at the same time.
All potentiometric sensors feature a double junction design
and are gel filled to increase resistance to contamination.
One of the ISE sensors can be used in place of the pH sensor
and is automatically recognized. pH in mV readings are
also displayed —which is useful for troubleshooting.
7
HI7629829
for pH/ORP, Dissolved
Oxygen, EC, Logging
Multiparameter
HI7609829
for pH/ORP, Dissolved
Oxygen, EC
With two probes to choose from, these digital probes provide stable, noise-free sensor
signal management without the need for pre-amplified pH sensors.
Specifications
Supported
Configuration
HI7609829
HI7629829
Connector 1
pH, pH/ORP, ammonium ISE,
chloride ISE, nitrate ISE
pH, pH/ORP, ammonium ISE,
chloride ISE, nitrate ISE
Connector 2
dissolved oxygen
dissolved oxygen
Connector 3
EC
EC
built-in
built-in
Autonomous Logging
—
yes
Logging Interval
—
1 second to 3 hours
Computer Interface
—
USB (HI76982910)
Memory
—
140,000 measurements (single parameter logged);
35,000 measurements (all parameters logged)
Operating Temperature
-5 to 55°C*
-5 to 55°C*
Maximum Depth
20 m (66’)*
20 m (66’)*
Cable Specification
multistrand-multiconductor shielded cable with internal strength member rated for 68 kg (150 lb.) intermittent use
Wetted Materials
body: ABS; threads: nylon; shield: ABS/316 SS; temperature probe: 316 SS; O-rings: EPDM
Logging Probe
Internal Battery Type
—
Logging Probe Battery Life
Note: Log space must be available for
continuous logging
portable
Temperature sensor
1.5V (4) AA alkaline
Interval
all channels logging
(no averaging)
1-5 seconds
72 hours
1 minute
22 days
10 minutes
70 days
—
Sample Environment
fresh, brackish, seawater
fresh, brackish, seawater
Waterproof Protection
IP68
IP68
Dimensions (without cable)
342 mm (13.5”), dia=46 mm (1.8”)
442 mm (17.4”), dia 46 mm (1.8”)
Weight (with batteries
and sensors)
570 g (20.1 oz.)
775 g (27.3 oz.)
* Reduced for ISE sensors
www.hannainst.com |
7.25
7
Sensor Configurations
Multiparameter
Both probes can accommodate a multitude of sensor configurations. The long sensor cap fits all configurations
while the short sensor cap fits configurations not requiring the turbidity/EC sensor.
or
Dissolved Oxygen
HI7609829-2 DO
pH
ISE
HI7609829-0 pH
HI7609829-10 Ammonium ISE
HI7609829-1 pH/ORP
HI7609829-11 Chloride ISE
portable
HI7609829-12 Nitrate ISE
The dissolved oxygen in lakes, rivers, and
oceans is crucial for the organisms and
creatures living in it. If dissolved oxygen
concentrations drop below normal levels in
water bodies, the water quality degrades
and the organisms begin to die off. The
HI7609829-2 galvanic DO sensor does not
require long polarization times so is ready
for measurement at a moment’s notice.
This sensor also utilizes a replaceable
cap design for ease of maintenance and a
safe, non-toxic electrolyte. DO readings
are compensated for the effects of
temperature (using the probe’s built-in
temperature sensor) and atmospheric
pressure (using the HI 9829’s internal
atmospheric pressure sensor). The DO
measurement complies with standard
methods 4500-0 G and EPA article 360.1.
The HI7609829-0 and -1 feature a double
junction design and are gel filled to increase
resistance to contamination. These pH or
pH/ORP sensors incorporate the technology
that has made Hanna so successful as a pH
manufacturer. Reliable pH measurements are
one of the most important indicators of water
chemistry indicating the relative amount of
free hydrogen and hydroxyl ions in the water.
Hanna’s pH sensors utilize a resilient PEI
body to protect them from solid particulates
found in water samples. Consistency and
quality are the hallmarks of these sensors.
Our differential measurement system further
enhances the measurement reliability,
providing temperature corrected pH.
A choice of three ion selective
electrodes (ISE) is available for constant
reporting of common surface water
contaminants. Nitrate, ammonium and
chloride ISEs are available. Each ISE is a
combination electrode incorporating an
extremely constant reference spiral; all
potentionmetric probes feature a double
junction and solid gel reference design.
The HI9829 displays measurements of
ion activity as ppm ammonium-nitrogen,
ppm chloride, and ppm nitrate-nitrogen.
HI7698295
Short cap for probes without
EC/turbidity sensor
7.26
| www.hannainst.com
7
Multiparameter
or
Conductivity
HI7609829-3 EC
Conductivity and
Turbidity
HI7609829-4 EC/Turbidity
The HI7609829-3 4-electrode conductivity
sensor using the polarographic
measurement principal ensures stable
conductivity readings. Electrolytic
conductivity measures the ability of water
to conduct an electrical current. It is highly
dependent on the amount of dissolved
solids (such as salt) in the water. Absolute
conductivity, temperature-corrected
conductivity, salinity. Seawater and water
hardness (TDS) determinations are possible
with measurements from this sensor.
portable
The HI7609829-4 combined EC/turbidity
sensor is a replaceable design for
instantaneous conductivity and turbidity
measurements that conform to ISO 7027
standards. It provides measurements
from 0.0 to 1000 FNU. Turbidity is the
amount of particulate matter that is
suspended in water. Turbidity measures
the scattering effect that suspended solids
have on light: the higher the intensity of
scattered light, the higher the turbidity.
Material that causes water to be turbid
include: clay, silt, finely divided organic and
inorganic matter, soluble colored organic
compounds, plankton and microscopic
organisms. Conductivity measurement
is the same as in the HI7609829-3.
HI7698296
Long cap for probes with
EC/turbidity sensor
www.hannainst.com |
7.27
7
Monitoring and Tracking
Multiparameter
The HI9829 with GPS module can track measurement
locations with detailed coordinate information. All models
of the HI9829 are equipped with the Fast Tracker™ TAG
ID system which is an invaluable tool for associating
measurements with their locations. The HI9829 also
incorporates a real-time clock which stamps all logged data
with a time and date in addition to location information.
GPS (Global Positioning System)
The HI9829 with GPS features an internal 12 channel GPS
receiver and antenna that calculates its position to track
locations along with measurement data. The GPS tracks your
location using satellites to within 30 ft (10 m) so you can be sure
that you return to the same location for repeated measurements.
The GPS coordinates can be shown on the LCD together with
up to 10 measurement parameters and are recorded with
logged data. Users can connect to GPS tracking software such
as Google™ Maps* to view locations where samples have been
taken. Measurement information is shown right on the map.
Features
• Basic GPS Features
· GPS coordinates shown on the LCD with
up to 10 measurement parameters
· GPS signal strength shown on LCD
· Logged data is embedded with GPS coordinates
· GPS status screen
portable
• Advanced GPS Features
· Users can associate GPS coordinates
with alphanumeric locations
· Distances between current location and predefined
locations are displayed arranged by distance
· Memorizes last location and time should signal be lost
• HI929829 PC Application Software
· Manages logged data from the HI9829
· Displays GPS coordinates with logged data
· Automatically maps samples on your PC
(internet connection required)
· Shows location points on map with measurement data
Fast Tracker™—Tag Identification System
HANNA’s Fast Tracker™—Tag Identification System simplifies test
logging. iButton®s with a unique ID can be installed at various sampling
sites. When the matching connector on the meter contacts the location
button, measurements are logged and labeled with the alphanumeric
user-entered location ID. Location, date, time and measurements
are logged into the meter which can be transferred to a PC. The Fast
Tracker™ system complements the GPS for ultimate tracking.
iButton® Tags are Easy to Install
Install the optional TAGs near your sampling points for quick
and easy iButton® readings. Each TAG contains a computer chip
with a unique identification code encased in stainless steel. You
can install a practically unlimited amount of TAGs. Additional
TAGs can be ordered for all of your traceability requirements.
*Google™ is a registered trademark of Google™, inc. HANNA Instruments® has no affiliation with Google™.
7.28
| www.hannainst.com
GPS Screen Features
Multiparameter
• GPS data can be customized to meet
specific requirement
7
• Displays distances between current and
predefined locations
portable
• Display current readings along with
GPS coordinates
• Shows current position and number
of satellites
*Google™ is a registered trademark of Google™, inc. HANNA Instruments® has no affiliation with Google™.
www.hannainst.com |
7.29
portable
Multiparameter
7
7.30
Specifications
HI9829
HI9829 with GPS
Temperature
Compensation
automatic from -5 to 55°C (23 to 131°F)
automatic from -5 to 55°C (23 to 131°F)
GPS
—
12 channel receiver, 10 m (30 ft) range
Logging Memory
from Meter
44,000 records
44,000 records
Logging Interval
1 second to 3 hours
1 second to 3 hours
Computer Interface
USB (with HI 929829 software)
USB (with HI929829 software)
FastTracker™ TAG ID
Yes
Yes
Waterproof Protection
IP67
IP67
Environment
0 to 50°C (32 to 122°F); RH 100%
0 to 50°C (32 to 122°F); RH 100%
Power Supply
1.5V alkaline C cells (4) / 1.2V NiMH rechargeable C cells (4),
USB, 12V power adapter
1.5V alkaline C cells (4) / 1.2V NiMH rechargeable C cells (4),
USB, 12V power adapter
Dimensions
221 x 115 x 55 mm (8.7 x 4.5 x 2.2”)
221 x 115 x 55 mm (8.7 x 4.5 x 2.2”)
Weight
750g (26.5 oz.)
750g (26.5 oz.)
HI9829 Parameter Specifications
AmmoniumNitrogen
Chloride
NitrateNitrogen
0.02 to 200
ppm (as N)
0.62 to 200
ppm (as N)
pH / mV of pH input
ORP mV
Range
0.00 to 14.00 pH / ±600.0 mV
±2000.0 mV
Resolution
0.01 pH / 0.1 mV
0.1 mV
0.01 ppm to 1 ppm; 0.1 ppm to 200 ppm
Accuracy
±0.02 pH / ±0.5 mV
±1.0 mV
±5% of reading or 2 ppm, whichever is greater
Calibration
automatic one, two, or three points with five memorized standard buffers
(pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer
automatic at one
custom point
1 or 2 point, 10 ppm and 100 ppm
Conductivity
TDS
Resistivity
Salinity
Range
0 to 200 mS/cm
(absolute EC up to 400 mS/cm)
0 to 400000 mg/L or ppm
(the maximum value depends
on the TDS factor)
0 to 999999 Ω•cm;
0.00 to
0 to 1000.0 kΩ•cm;
70.00 PSU
0 to 1.0000 MΩ•cm
Resolution
manual:
1 μS/cm; 0.001 mS/cm; 0.01 mS/cm;
0.1 mS/cm; 1 mS/cm;
automatic:
1 μS/cm from 0 to 9999 μS/cm;
0.01 mS/cm from 10.00 to 99.99 mS/cm;
0.1 mS/cm from 100.0 to 400.0 mS/cm;
automatic mS/cm:
0.001 mS/cm from 0.000 to 9.999 mS/cm;
0.01 mS/cm from 10.00 to 99.99 mS/cm;
0.1 mS/cm from 100.0 to 400.0 mS/cm
manual:
1 mg/L (ppm); 0.001 g/L (ppt);
0.01g/L (ppt); 0.1 g/L (ppt); 1 g/L (ppt);
automatic:
1 mg/L (ppm) from 0 to 9999 mg/L (ppm);
dependent on
0.01 g/L (ppt) from 10.00 to 99.99 g/L (ppt);
resistivity reading
0.1 g/L (ppt) from 100.0 to 400.0 g/L (ppt);
autorange g/L (ppt) scales:
0.001 g/L (ppt) from 0.000 to 9.999 g/L (ppt);
0.01 g/L (ppt) from 10.00 to 99.99 g/L (ppt);
0.1 g/L (ppt) from 100.0 to 400.0 g/L (ppt)
0.01 PSU
Accuracy
±1% of reading or ±1 μS/cm,
whichever is greater
±1% of reading or ±1 mg/L,
whichever is greater
±2% of reading
or ±0.01 PSU,
±1 ıt, ı0, ı15
whichever is
greater
Calibration
automatic one point with six memorized
standards (84 μS/cm, 1413 μS/cm, 5.00
mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8
mS/cm) or custom point
based on conductivity or salinity calibration
Turbidity
Dissolved Oxygen
Atm. Pressure
Temperature
-5.00 to 55.00°C;
23.00 to 131.00°F;
268.15 to 328.15K
—
one custom
point
0.6 to
200 ppm
Seawater ı
0 to 50.0 ıt, ı0, ı15
0.1 ıt, ı0, ı15
based on conductivity or
salinity calibration
Range
0.0 to 99.9 FNU;
100 to 1000 FNU
0.0 to 500.0%;
0.00 to 50.00 ppm
450 to 850 mm Hg;
17.72 to 33.46 in Hg;
600.0 to 1133.2 mbar;
8.702 to 16.436 psi;
0.5921 to 1.1184 atm;
60.00 to 113.32 kPa
Resolution
0.1 FNU from 0.0 to 99.9 FNU;
1 FNU from 100 to 1000 FNU
0.1%; 0.01 ppm
0.1 mm Hg; 0.01 in Hg; 0.1 mbar;
0.001 psi; 0.0001 atm; 0.01 kPa
0.01°C; 0.01°F; 0.01K
Accuracy
±0.3 FNU or ±2% of reading,
whichever is greater
0.0 to 300.0%: ±1.5% of reading or
±1.0% whichever is greater; 300.0 to
500.0%: ±3% of reading; 0.00 to
30.00 ppm: ±1.5% of reading or 0.10 ppm,
whichever is greater; 30.00 ppm to
50.00 ppm: ±3% of reading
±3 mm Hg within ±15°C
from the temperature
during calibration
±0.15°C; ±0.27°F; ±0.15K
Calibration
Automatic 1, 2 or 3 points at 0, 20 and 200 automatic one or two points at 0, 100% or
FNU, or custom
one custom point
automatic at one
custom point
Automatic at one
custom point
| www.hannainst.com
solutions and accessories begin on page 7.34
Ordering Information
Meter and Probe with Rugged Carrying Case
HI9829 —
w
x
7
z
y
W=
0
Basic meter, no GPS
1
Meter with GPS
0
No turbidity basic probe
1
Turbidity basic probe
2
Autonomously logging probe,
no turbidity
3
Autonomously logging probe
with turbidity
x=
y=
4 meter cable length
10
10 meter cable length
20
20 meter cable length
Z=
1
115V
2
230V
Multiparameter
04
z=1 is supplied with 115V AC to 12V DC Adapter
HI76982910 USB cable (PC to Probe)
HI9829-18 200 FNU calibration solution
HI9829-17 20 FNU calibration solution
•
•
•
HI9829-0010Z
HI7609829/10
•
•
•
HI9829-0020Z
HI7609829/20
•
•
HI7698291 USB cable (PC to meter)
HI9829-0104Z
HI7609829/4
•
•
•
•
•
•
HI710045 Power supply cable
HI9829-0110Z
HI7609829/10
•
•
•
•
•
•
HI710046 Cigarette lighter cable
HI9829-0120Z
HI7609829/20
•
•
•
•
•
•
HI9829-0204Z
HI7629829/4
•
•
•
•
HI9829-0210Z
HI7629829/10
•
•
•
•
HI9829-0220Z
HI7629829/20
•
•
•
•
HI9829-0304Z
HI7629829/4
•
•
•
•
•
•
•
HI9829-0310Z
HI7629829/10
•
•
•
•
•
•
•
HI9829-0320Z
HI7629829/20
•
•
•
•
•
•
•
HI7609829-12 Nitrate sensor
HI710140 Hard carrying case
HI7619829-11 Chloride ISE sensor
HI710005/8 (115V) or HI710006/8 (230V)
HI7609829-10 Ammonium ISE sensor
Mulitiparameter Probe (see table)
HI7698297 Long quick release flow cell
HI7698292 Probe Maintenance Kit
Spare Solution (see below)
HI929829 Application Software
•
HI7609829-2 Galvanic DO Sensor
HI920005 iButton® with holder (5 pcs)
HI9828-25 Calibration solution
Instruction Manual
Spare Solution
HI9829-1004Z
HI7609829/4
•
•
•
HI9829-10
25 sachets 10ppm ammonia-nitrogen calibration solution
HI9829-1010Z
HI7609829/10
•
•
•
HI9829-10/11
10 sachets each of 10ppm and 100ppm ammonia-nitrogen
calibration solution
HI9829-1020Z
HI7609829/20
•
•
HI9829-1104Z
HI7609829/4
•
•
•
•
•
•
HI9829-1110Z
HI7609829/10
•
•
•
•
•
•
HI9829-1120Z
HI7609829/20
•
•
•
•
•
HI9829-1204Z
HI7629829/4
•
•
•
•
HI9829-1210Z
HI7629829/10
•
•
•
•
HI9829-1220Z
HI7629829/20
•
•
•
•
HI9829-1304Z
HI7629829/4
•
•
•
•
•
•
•
HI9829-1310Z
HI7629829/10
•
•
•
•
•
•
•
HI9829-1320Z
HI7629829/20
•
•
•
•
•
•
•
HI9829-11
•
25 sachets 100ppm ammonia-nitrogen calibration solution
HI9829-12
25 sachets 10ppm chloride calibration solution
HI9829-12/13
10 sachets each of 10ppm and 100ppm chloride calibration
solution
HI9829-13
25 sachets 100ppm chloride calibration solution
HI9829-14
portable
HI7609829-1 pH/ORP sensor
HI7698296 long protective sleeve
HI7609829/4
HI9829 or HI 98290 (GPS Model)
Kit Specific
Components:
HI7698295 Short protective sleeve
HI7698290 Short calibration beaker
HI9829-0004Z
Optional Kit
Components:
HI7698293 Long calibration beaker
Probe
All HI9829 Kits
Include:
HI7609829-4 EC/Turbidity Sensor
Kit Number
HI7609829-3 EC Sensor
HI9829-16 0 FNU calibration solution
z=2 is supplied with 230V AC to 12V DC Adapter
25 sachets 10ppm nitrate-nitrogen calibration solution
HI9829-14/15
10 sachets each of 10ppm and 100ppm nitrate-nitrogen
calibration solution
HI9829-15
25 sachets 100ppm nitrate-nitrogen calibration solution
solutions and accessories begin on page 7.34
www.hannainst.com |
•
7.31
7
Meter with Probe Ordering Information
Choose Your Configuration Below
Multiparameter
Meter and Probe with Rugged Carrying Case
Basic
portable
GPS
Basic & Turbidity
GPS & Turbidity
HI9829-00041 (115V)
HI9829-00042 (230V)
HI9829 meter, HI7609829/4 probe, HI7698291 USB cable (PC to meter), HI920005 iButton® with holder (5 pcs),
HI929829 PC application software, HI7609829-3 EC sensor, HI7609829-2 DO sensor, HI7609829-1 pH/ORP sensor,
HI710045 power supply cable, HI7698292 probe maintenance kit, HI7698290 short calibration beaker,
HI9828-25 calibration solution (500 mL), HI710046 cigarette lighter cable, HI710005/8 (115V) or HI710006/8 (230V),
instruction manual.
HI9829-00101 (115V)
HI9829-00102 (230V)
HI9829 meter, HI7609829/10 probe, HI7698291 USB cable (PC to meter), HI920005 iButton® with holder (5 pcs),
HI929829 PC application software, HI7609829-3 EC sensor, HI7609829-2 DO sensor, HI7609829-1 pH/ORP sensor,
HI710045 power supply cable, HI7698292 probe maintenance kit, HI7698290 short calibration beaker,
HI9828-25 calibration solution (500 mL), HI710046 cigarette lighter cable, HI710005/8 (115V) or HI710006/8 (230V),
instruction manual.
HI9829-00201 (115V)
HI9829-00202 (230V)
HI9829 meter, HI7609829/20 probe, HI7698291 USB cable (PC to meter), HI920005 iButton® with holder
(5 pcs), HI929829 PC application software, HI7609829-3 EC sensor, HI7609829-2 DO sensor, HI7609829-1 pH/ORP
sensor, HI710045 power supply cable, HI7698292 probe maintenance kit, HI7698290 short calibration beaker,
HI9828-25 calibration solution (500 mL), HI710046 cigarette lighter cable, HI710005/8 (115V) or HI710006/8 (230V),
instruction manual.
HI9829-10041 (115V)
HI9829-10042 (230V)
HI9829 meter with GPS, HI7609829/4 probe, HI7698291 USB cable (PC to meter), HI920005 iButton® with holder
(5 pcs), HI929829 PC application software, HI7609829-3 EC sensor, HI7609829-2 DO sensor, HI7609829-1 pH/ORP
sensor, HI710045 power supply cable, HI7698292 probe maintenance kit, HI7698290 short calibration beaker,
HI9828-25 calibration solution (500 mL), HI710046 cigarette lighter cable, HI710005/8 (115V) or HI710006/8 (230V),
instruction manual.
HI9829-10101 (115V)
HI9829-10102 (230V)
HI9829 meter with GPS, HI7609829/10 probe, HI7698291 USB cable (PC to meter), HI920005 iButton® with holder
(5 pcs), HI929829 PC application software, HI7609829-3 EC sensor, HI7609829-2 DO sensor, HI7609829-1 pH/ORP
sensor, HI710045 power supply cable, HI7698292 probe maintenance kit, HI7698290 short calibration beaker,
HI9828-25 calibration solution (500 mL), HI710046 cigarette lighter cable, HI710005/8 (115V) or HI710006/8 (230V),
instruction manual.
HI9829-10201 (115V)
HI9829-10202 (230V)
HI9829 meter with GPS, HI7609829/20 probe, HI7698291 USB cable (PC to meter), HI920005 iButton® with holder
(5 pcs), HI929829 PC application software, HI7609829-3 EC sensor, HI7609829-2 DO sensor, HI7609829-1 pH/ORP
sensor, HI710045 power supply cable, HI7698292 probe maintenance kit, HI7698290 short calibration beaker,
HI9828-25 calibration solution (500 mL), HI710046 cigarette lighter cable, HI710005/8 (115V) or HI710006/8 (230V),
instruction manual.
HI9829-01041 (115V)
HI9829-01042 (230V)
HI9829 meter, HI7609829/4 probe, HI7698291 USB cable (PC to meter), HI920005 iButton® with holder (5 pcs),
HI929829 PC application software, HI7609829-2 DO sensor, HI7609829-1 pH/ORP sensor, HI7609829-4 EC/Turbidity
sensor, HI710045 power supply cable, HI7698292 probe maintenance kit, HI9829-16 0 FNU calibration solution (230
mL), HI9829-17 20 FNU calibration solution (230 mL), HI9829-18 200 FNU calibration solution
(230 mL), HI7698293 long calibration beaker, HI9828-25 calibration solution (500 mL), HI710046 cigarette lighter
cable, HI710005/8 (115V) or HI710006/8 (230V), instruction manual.
HI9829-01101 (115V)
HI9829-01102 (230V)
HI9829 meter, HI7609829/10 probe, HI7698291 USB cable (PC to meter), HI920005 iButton® with holder (5 pcs),
HI929829 PC application software, HI7609829-2 DO sensor, HI7609829-1 pH/ORP sensor, HI7609829-4 EC/Turbidity
sensor, HI710045 power supply cable,HI7698292 probe maintenance kit, HI9829-16 0 FNU calibration solution (230
mL), HI9829-17 20 FNU calibration solution (230 mL), HI9829-18 200 FNU calibration solution (230 mL), HI7698293
long calibration beaker, HI9828-25 calibration solution (500 mL), HI710046 cigarette lighter cable,
HI710005/8 (115V) or HI710006/8 (230V), instruction manual.
HI9829-01201 (115V)
HI9829-01202 (230V)
HI9829 meter, HI7609829/20 probe, HI7698291 USB cable (PC to meter), HI920005 iButton® with holder (5 pcs),
HI929829 PC application software, HI7609829-2 DO sensor, HI7609829-1 pH/ORP sensor, HI7609829-4 EC/Turbidity
sensor, HI710045 power supply cable,HI7698292 probe maintenance kit, HI9829-16 0 FNU calibration solution (230
mL), HI9829-17 20 FNU calibration solution (230 mL), HI9829-18 200 FNU calibration solution
(230 mL), HI7698293 long calibration beaker, HI9828-25 calibration solution (500 mL), HI710046 cigarette lighter
cable, HI710005/8 (115V) or HI710006/8 (230V), instruction manual.
HI9829-11041 (115V)
HI9829-11042 (230V)
HI9829 meter with GPS, HI7609829/4 probe, HI7698291 USB cable (PC to meter), HI920005 iButton® with holder
(5 pcs), HI929829 PC application software, HI7609829-2 DO sensor, HI7609829-1 pH/ORP sensor, HI7609829-4
EC/Turbidity sensor, HI710045 power supply cable, HI7698292 probe maintenance kit, HI9829-16 0 FNU calibration
solution (230 mL), HI9829-17 20 FNU calibration solution (230 mL), HI9829-18 200 FNU calibration solution
(230 mL), HI7698293 long calibration beaker, HI9828-25 calibration solution (500 mL), HI710046 cigarette lighter
cable, HI710005/8 (115V) or HI710006/8 (230V), instruction manual.
HI9829-11101 (115V)
HI9829-11102 (230V)
HI9829 meter with GPS, HI7609829/10 probe, HI7698291 USB cable (PC to meter), HI920005 iButton® with holder
(5 pcs), HI929829 PC application software, HI7609829-2 DO sensor, HI7609829-1 pH/ORP sensor, HI7609829-4
EC/Turbidity sensor, HI710045 power supply cable, HI7698292 probe maintenance kit, HI9829-16 0 FNU calibration
solution (230 mL), HI9829-17 20 FNU calibration solution (230 mL), HI9829-18 200 FNU calibration solution
(230 mL), HI7698293 long calibration beaker, HI9828-25 calibration solution (500 mL), HI710046 cigarette lighter
cable, HI710005/8 (115V) or HI710006/8 (230V), instruction manual.
HI9829-11201 (115V)
HI9829-11202 (230V)
HI9829 meter with GPS, HI7609829/20 probe, HI7698291 USB cable (PC to meter), HI920005 iButton® with holder
(5 pcs), HI929829 PC application software, HI7609829-2 DO sensor, HI7609829-1 pH/ORP sensor, HI7609829-4
EC/Turbidity sensor, HI710045 power supply cable, HI7698292 probe maintenance kit, HI9829-16 0 FNU calibration
solution (230 mL), HI9829-17 20 FNU calibration solution (230 mL), HI9829-18 200 FNU calibration solution
(230 mL), HI7698293 long calibration beaker, HI9828-25 calibration solution (500 mL), HI710046 cigarette lighter
cable, HI710005/8 (115V) or HI710006/8 (230V), instruction manual.
Mulitiparameter Probe (Cable length: 4m, 10m, 20m)
7.32
| www.hannainst.com
solutions and accessories begin on page 7.34
Meter with Probe Ordering Information
7
Choose Your Configuration Below
Meter and Logging Probe with Rugged Carrying Case
GPS with
Autonomously
Logging Probe
GPS with
Autonomously
Logging Probe &
Turbidity
HI9829-02101 (115V)
HI9829-02102 (230V)
HI9829 meter, HI7629829/10 probe, HI76982910 USB cable (PC to Probe), HI7698291 USB cable (PC to meter),
HI929829 PC application software, HI920005 iButton® with holder (5 pcs), HI7609829-3 EC sensor, HI7609829-2 DO
sensor, HI7609829-1 pH/ORP sensor, HI710045 power supply cable, HI7698290 short calibration beaker, HI9828-25
calibration solution (500 mL), HI710005/8 (115V) or HI710006/8 (230V), instruction manual.
HI9829-02201 (115V)
HI9829-02202 (230V)
HI9829 meter, HI7629829/20 probe, HI76982910 USB cable (PC to Probe), HI7698291 USB cable (PC to meter),
HI929829 PC application software, HI920005 iButton® with holder (5 pcs), HI7609829-3 EC sensor, HI7609829-2 DO
sensor, HI7609829-1 pH/ORP sensor, HI710045 power supply cable, HI7698290 short calibration beaker, HI9828-25
calibration solution (500 mL), HI710005/8 (115V) or HI710006/8 (230V), instruction manual.
HI9829-12041 (115V)
HI9829-12042 (230V)
HI9829 meter with GPS, HI7629829/4 probe, HI76982910 USB cable, (PC to Probe), HI7698291 USB cable (PC to
meter), HI929829 PC application software, HI920005 iButton® with holder (5 pcs), HI7609829-3 EC sensor,
HI7609829-2 DO sensor, HI7609829-1 pH/ORP sensor, HI710045 power supply cable, HI7698290 short calibration
beaker, HI9828-25 calibration solution (500 mL), HI710005/8 (115V) or HI710006/8 (230V), instruction manual.
HI9829-12101 (115V)
HI9829-12102 (230V)
HI9829 meter with GPS, HI7629829/10 probe, HI76982910 USB cable (PC to Probe), HI7698291 USB cable (PC
to meter), HI929829 PC application software, HI920005 iButton® with holder (5 pcs), HI7609829-3 EC sensor,
HI7609829-2 DO sensor, HI7609829-1 pH/ORP sensor, HI710045 power supply cable, HI7698290 short calibration
beaker, HI9828-25 calibration solution (500 mL), HI710005/8 (115V) or HI710006/8 (230V), instruction manual.
HI9829-12201 (115V)
HI9829-12202 (230V)
HI9829 meter with GPS, HI7629829/20 probe, HI76982910 USB cable (PC to Probe), HI7698291 USB cable (PC to
meter), HI929829 PC application software, HI920005 iButton® with holder (5 pcs), HI7609829-3 EC sensor,
HI7609829-2 DO sensor, HI7609829-1 pH/ORP sensor, HI710045 power supply cable, HI7698290 short calibration
beaker, HI9828-25 calibration solution (500 mL), HI710005/8 (115V) or HI710006/8 (230V), instruction manual.
HI9829-03041 (115V)
HI9829-03042 (230V)
HI9829 meter, HI7629829/4 probe, HI76982910 USB cable (PC to Probe), HI7698291 USB cable (PC to meter),
HI929829 PC application software, HI920005 iButton® with holder (5 pcs), HI7609829-2 DO sensor, HI7609829-1
pH/ORP sensor, HI7609829-4 EC/Turbidity sensor, HI710045 power supply cable, HI7698292 probe maintenance kit,
HI9829-16 0 FNU calibration solution (230 mL), HI9829-17 20 FNU calibration solution (230 mL), HI9829-18 200 FNU
calibration solution (230 mL), HI7698293 long calibration beaker, HI9828-25 calibration solution (500 mL), HI710046
cigarette lighter cable, HI710005/8 (115V) or HI710006/8 (230V), instruction manual.
HI9829-03101 (115V)
HI9829-03102 (230V)
HI9829 meter, HI7629829/10 probe, HI76982910 USB cable (PC to Probe), HI7698291 USB cable (PC to meter),
HI929829 PC application software, HI920005 iButton® with holder (5 pcs), HI7609829-2 DO sensor, HI7609829-1
pH/ORP sensor, HI7609829-4 EC/Turbidity sensor, HI710045 power supply cable, HI7698292 probe maintenance kit,
HI9829-16 0 FNU calibration solution (230 mL), HI9829-17 20 FNU calibration solution (230 mL), HI9829-18 200 FNU
calibration solution (230 mL), HI7698293 long calibration beaker, HI9828-25 calibration solution (500 mL), HI710046
cigarette lighter cable, HI710005/8 (115V) or HI710006/8 (230V), instruction manual.
HI9829-03201 (115V)
HI9829-03202 (230V)
HI9829 meter, HI7629829/20 probe, HI76982910 USB cable (PC to Probe), HI7698291 USB cable (PC to meter),
HI929829 PC application software, HI920005 iButton® with holder (5 pcs), HI7609829-2 DO sensor, HI7609829-1
pH/ORP sensor, HI7609829-4 EC/Turbidity sensor, HI710045 power supply cable, HI7698292 probe maintenance kit,
HI9829-16 0 FNU calibration solution (230 mL), HI9829-17 20 FNU calibration solution (230 mL), HI9829-18 200 FNU
calibration solution (230 mL), HI7698293 long calibration beaker, HI9828-25 calibration solution (500 mL), HI710046
cigarette lighter cable, HI710005/8 (115V) or HI710006/98(230V), instruction manual.
HI9829-13041 (115V)
HI9829-13042 (230V)
HI9829 meter with GPS, HI7629829/4 probe,HI76982910 USB cable, (PC to Probe), HI7698291 USB cable (PC to meter),
HI929829 PC application software, HI920005 iButton® with holder (5 pcs), HI7609829-2 DO sensor,
HI7609829-1 pH/ORP sensor, HI7609829-4 EC/Turbidity sensor, HI710045 power supply cable, HI7698292 probe
maintenance kit, HI9829-16 0 FNU calibration solution (230 mL), HI9829-17 20 FNU calibration solution (230 mL),
HI9829-18 200 FNU calibration solution (230 mL), HI7698293 long calibration beaker, HI9828-25 calibration solution
(500 mL), HI710046 cigarette lighter cable, HI710005/8 (115V) or HI710006/8 (230V), instruction manual.
HI9829-13101 (115V)
HI9829-13102 (230V)
HI9829 meter with GPS, HI7629829/10 probe,HI76982910 USB cable (PC to Probe), HI7698291 USB cable (PC to
meter), HI929829 PC application software, HI920005 iButton® with holder (5 pcs), HI7609829-2 DO sensor,
HI7609829-1 pH/ORP sensor, HI7609829-4 EC/Turbidity sensor, HI710045 power supply cable,HI7698292 probe
maintenance kit, HI9829-16 0 FNU calibration solution (230 mL), HI9829-17 20 FNU calibration solution (230 mL),
HI9829-18 200 FNU calibration solution (230 mL), HI7698293 long calibration beaker, HI9828-25 calibration solution
(500 mL), HI710046 cigarette lighter cable, HI710005/8 (115V) or HI710006/8 (230V),instruction manual.
HI9829-13201 (115V)
HI9829-13202 (230V)
HI9829 meter with GPS, HI7629829/20 probe,HI76982910 USB cable (PC to Probe), HI7698291 USB cable (PC to
meter), HI929829 PC application software, HI920005 iButton® with holder (5 pcs), HI7609829-2 DO sensor,
HI7609829-1 pH/ORP sensor, HI7609829-4 EC/Turbidity sensor, HI710045 power supply cable, HI7698292 probe
maintenance kit, HI9829-16 0 FNU calibration solution (230 mL), HI9829-17 20 FNU calibration solution (230 mL),
HI9829-18 200 FNU calibration solution (230 mL), HI7698293 long calibration beaker, HI9828-25 calibration solution
(500 mL), HI710046 cigarette lighter cable, HI710005/8 (115V) or HI710006/8 (230V), instruction manual.
solutions and accessories begin on page 7.34
www.hannainst.com |
portable
Basic with
Autonomously
Logging Probe &
Turbidity
HI9829 meter, HI7629829/4 probe, HI76982910 USB cable (PC to Probe), HI7698291 USB cable (PC to meter),
HI929829 PC application software, HI920005 iButton® with holder (5 pcs), HI7609829-3 EC sensor, HI7609829-2 DO
sensor, HI7609829-1 pH/ORP sensor, HI710045 power supply cable, HI7698290 short calibration beaker, HI9828-25
calibration solution (500 mL), HI710005/8 (115V) or HI710006/8 (230V), instruction manual.
Multiparameter
Basic with
Autonomously
Logging Probe
HI9829-02041 (115V)
HI9829-02042 (230V)
7.33
Download PDF
Similar pages