Comfort Where It Counts.
13 SEER DUCTLESS SPLIT SYSTEMS
Full Line of Air Conditioners and Heat Pumps
That Meet 13 SEER and 7.7 HSPF Requirements.
13 SEER Ductless Split Systems
Convenient, Efficient,
Easy To Operate
Made in the USA
Whether you’re adding on or modifying an existing
commercial or residential structure, EMI America
Series Ductless Split Systems make it easy to enjoy
conditioned comfort minus the ductwork. Efficiently
designed America Series Ductless Split Systems allow
you to cut your energy costs by cooling or heating
zones as required. Unlike central air, each zone is
controlled independently allowing you to use energy
wisely – only where and when you need it. Easily operated America Series
systems feature your choice of unit mount digital controls, hand-held
infra-red remote controls or 24-volt wall mount thermostats.
The EMI America Series Advantage
EMI’s America Series line of ductless split air conditioning is the most
comprehensive, flexible and unique ductless line in the industry. Select
from over 130 single or multi-zone systems for cooling only or heat pump
applications. With exceptional performance, operating efficiency, and
EMI exclusive features – the EMI America Series is the number one
choice for “Comfort Where It Counts.”
EMI America Series Systems Feature:
Optional electric heat on both straight cool and heat pump air handlers
Standard single zone cooling operation down to 60°F (15°C)
outside temperature
● Standard single and multi-zone heat pump operation down to
0˚F (-18˚C) outside temperature
● The flexibility of a full line of air handlers
● Air handler capabilities from 9,000 – 36,000 BTUH (2.6 – 10.5 kW)
● Low voltage interconnect between air handler and condenser
● 100 ft. of total interconnect (maximum of 35 ft. vertical lift)
● Factory-Installed Integral Condensate Pump (CACB/CAHB).
Field-Installed Accessory Condensate Pump (WLCA/WLHA and
UNCA/UNHA) with easy electrical and control connections
● All indoor units can be operated from a 24-Volt Wall Thermostat
● Schrader ports for ease of serviceability
● Multi-zone condensers and heat pumps capable of handling
up to four different types of air handlers
● Multi-zone heat pumps are capable of simultaneous heating
and cooling operation
● Brass service valves for isolation at condensers
● Condensate overflow protection
●
●
Peace of Mind
All America Series systems feature a 1-year parts
and 5-year compressor warranty with additional
5 and 10 years parts and labor Comfort Plus
Extended Warranties available.
1 3 S E E R M U LT I - Z O N E F L E X I B I L I T Y
Standard Comfort Features:
SINGLE ZONE
• Simple operation with unit
mounted digital control
• Fan cycling virtually eliminates
variations in room temperature
• Electric heat available on all units
(see charts for details)
Standard Installation
and Service Features:
• Simple electrical connections
for condensate pump
for the UNCA/UNHA
and WLCA/WLHA
• Integral condensate
drain overflow switch
ONE Condenser with choice
of ONE Air Handler style and
capacity tailored to a one zone
heating or cooling application.
M U LT I - Z O N E
ONE Condenser with up to FOUR independent
circuits, with individual Air Handler styles
and capacities tailored to each zone.
AIR HANDLERS
Wall Air Handlers
●
WLC Series Cooling (30,000 - 36,000 BTUH, 8.8 - 10.5 kW)
● WLH Series Cooling & Heat Pump (9,000 - 24,000 BTUH, 2.6 - 7.0 kW)
MODEL
WLHA09
WLHA12
WLHA24
WLCA30
WLCA36
NOMINAL
COOLING
CAP. BTUH, (kW)
NOMINAL
HEATING
CAP. BTUH, (kW)
OPTIONAL
HEATING
(115V)
OPTIONAL
HEATING
(208/230V)
9,000 (2.6)
11,800 (3.4)
18,000/24,000 (5.2/7.0)
30,000 (8.8)
33,600 (9.9)
8,200 (2.4)
10,200 (3.0)
16,400/20,600 (4.8/6.0)
N/A
N/A
.75 kW
.75 kW
.75 or 1.25 kW
N/A
N/A
3 kW
3 kW
3 or 5 kW
5 kW
5 kW
Comfort Where It Counts.
Wall Air Handler
Added Features Include:
●
●
●
Sweep function on louvers
provides a wide cooling area
Dry mode allows for
dehumidification, with minimal
change in room temperature
(requires electric heat)
Selectable filter indicator notifies
occupant when cleaning is required
●
●
●
Condensate pump accessory
includes integral safety switch
with 48" (1.2 m) available lift
Test mode overrides controls for
easy start-up and diagnostics
Optional wall thermostat or
handheld IR control
Cassette Air Handler
Cassette Air Handlers
●
●
CACB Series Cooling (30,000 - 36,000 BTUH, 8.8 - 10.5 kW)
CAHB Series Cooling & Heat Pump (9,000 - 24,000 BTUH, 2.6 - 7.0 kW)
MODEL
NOMINAL
COOLING
CAP. BTUH, (kW)
NOMINAL
HEATING
CAP. BTUH, (kW)
OPTIONAL ELECTRIC HEAT
(208/230V)
CAHB12
CAHB24
CACB36
9,000/11,800 (2.6/3.4)
18,000/23,000 (5.2/6.7)
30,000/36,000 (8.8/10.5)
8,000/10,800 (2.3/3.2)
15,000/20,000 (4.4/5.9)
N/A
1.5 kW
3.0 kW
5.0 kW
Added Features Include:
●
●
●
Universal Ceiling Air Handler
Factory installed condensate pump
includes integral safety switch
with 36" (0.9 m) available lift
Controls accept 24V wall thermostat
Easily configured for fresh air intake
and up to 2 branch discharge locations
●
●
●
Motorized discharge vanes on
CACB36 and CAHB24
Infra-red compatible remote control
with test mode
Selectable filter indicator notifies
occupant when unit needs filter change
Universal Ceiling/Floor Mount Air Handlers
●
●
UNCA Series Cooling (30,000 - 36,000 BTUH, 8.8 - 10.5 kW)
UNHA Series Cooling & Heat Pump (9,000 - 24,000 BTUH, 2.6 - 7.0 kW)
MODEL
UNHA09
UNHA12
UNHA24
UNCA36
NOMINAL
COOLING
CAP. BTUH, (kW)
NOMINAL
HEATING
CAP. BTUH, (kW)
OPTIONAL
HEATING
(115V)
OPTIONAL
HEATING
(208/230V)
9,000 (2.6)
11,800 (3.4)
18,000/24,000 (5.2/7.0)
30,000/32,600 (8.8/9.6)
7,800 (2.3)
10,200 (3.0)
16,400/20,600 (4.8/6.0)
N/A
.75 kW
.75 kW
.75 or 1.25 kW
N/A
3 kW
3 kW
3 or 5 kW
5 kW
Added Features Include:
●
●
●
Single unit can be used in either a
ceiling or floor mount application.
Multiple drain pans are factory installed,
no field modification required
Dry mode allows for dehumidification,
with minimal change in room
temperature (requires electric heat)
Test mode overrides controls for easy
start-up and diagnostics
●
●
●
●
●
Selectable filter indicator notifies
occupant when cleaning is required
Plastic filter grille standard, optional
metal grille available
Easily configured for fresh air intake
Optional wall thermostat or handheld
IR control
Condensate pump accessory includes
integral safety switch with 48" (1.2 m)
or 144" (3.6 m) available lift
Universal Floor Mount Air Handler
Comfort Where It Counts.
CONDENSERS
Side Discharge Condensers
●
Single Zone S1C Series Cooling (9,000 - 36,000 BTUH, 2.6 - 10.5 kW)
Single Zone S1H Series Heat Pump (9,000 - 24,000 BTUH, 2.6 - 7.0 kW)
● Dual Zone S2C Series Cooling (18,000 - 24,000 BTUH, 5.2 - 7.0 kW)
● Dual Zone S2H Series Heat Pump
(18,000 - 24,000 BTUH, 5.2 - 7.0 kW)
●
SINGLE ZONE
MODEL
NUMBER
OF CIRCUITS
NOMINAL COOLING
CAP. BTUH, (kW)
NOMINAL HEATING
CAP. BTUH, (kW)
S1CA9000/S1HA9000
S1CA2000/S1HA2000
S1CA8000/S1HA8000
S1CA4000/S1HA4000
S1CA3000
S1CA6000
1
1
1
1
1
1
9,000 (2.6)
12,000 (3.5)
18,000 (5.2)
24,000 (7.0)
30,000 (8.8)
36,000 (10.5)
N/A / 8,200 (2.4)
N/A / 10,200 (3.0)
N/A / 16,400 (4.8)
N/A / 20,600 (6.0)
N/A
N/A
DUAL ZONE
Side Discharge Condenser
MODEL
NUMBER
OF CIRCUITS
NOMINAL COOLING
CAP. BTUH, (kW)
NOMINAL HEATING
CAP. BTUH, (kW)
S2CA9900
S2CA9200
S2CA2200
S2HB9900
S2HB9200
S2HB2200
2
2
2
2
2
2
18,000 (5.2)
21,000 (6.2)
23,000 (6.7)
18,600 (5.5)
20,600 (6.0)
22,600 (6.6)
N/A
N/A
N/A
14,800 (4.3)
16,600 (4.9)
18,400 (5.4)
Comfort Features:
●
●
●
●
Hail Guard / Wind Baffle Accessory
●
●
●
●
●
●
●
Independent Refrigerant Circuits
●
Standard cooling operation down to 60°F (15°C) outside temperature
for S1C/S2C units, 32°F (0°C) for S1H and S2H
Standard heat pump operation down to 0˚F (-18˚C) outside temperature
Application flexibility with 100’ (30.5 m) of interconnect refrigerant piping,
supporting 35’ (10.6 m) of elevation difference
Side discharge cabinet with durable injection molded base and
enclosed compressor compartment for reduced noise
Coil ground clearance of 12” (0.3 m) provides added protection
from the environment year round
Front access to key components for ease of service
Industry standard R22 refrigerant
Easy access connections for refrigerant gauges
Corrosion resistant, powder-coated steel cabinet with coil protection
Factory installed Duratech Performance Package
(S1C/S1H9, S1C/S1H2, and S2C/S2H only)
Dual zone condensers and heat pumps have fully independent circuits
with compressors on each circuit. Available in 9,000 BTUH (2.6 kW)
and 12,000 BTUH (3.5 kW) circuits
One year parts, five year compressor warranty
MODE
T2CA9800/T2
T2CA8800/T2
T2CA2400/T2
T2CA8400/T2
T2CA4400/T2
T3CA9990/T3
T3CA9920/T3
T3CA9220/T3
T3CA2220/T3
T3CA9980/T3
T3CA9280/T3
T3CA9940/T3
T3CA2280/T3
T3CA9240/T3
T3CA2240/T3
T4CA9999/T4
T4CA9992/T4
T4CA9922/T4
T4CA9222/T4
T4CA2222/T4
Options:
●
●
●
●
●
Service & Refrigerant Line Connections
●
Low Ambient kits - field installed for operation down to
32°F (0°C) or 0°F (-18°C) (S1C, S1H, S2C)
Hard Start Kit - assists compressor start-up under abnormal
conditions such as low voltage
115V (9,000–12,000 BTUH, 2.6–3.5 kW). Consult factory for availability
Copper/Copper coils (sea coast use)
Condenser coil corrosion protection coating
Hail Guard/Wind Baffle
An I
CONDENSERS
Top Discharge Multi-Zone Condensers
T2CA, T3CA & T4CA Series Cooling
(27,000 - 48,000 BTUH, 7.9 - 14 kW)
● T2HB, T3HB & T4HB Series Heat Pump
(27,000 - 48,000 BTUH, 7.9 - 14 kW)
●
Comfort Features:
●
●
MULTI-ZONE
MODEL
NUMBER
OF
CIRCUITS
NOMINAL
COOLING CAP.
BTUH, (kW)
NOMINAL
HEATING CAP.
BTUH, (kW)
●
T2CA9800/T2HB9800
T2CA8800/T2HB8800
T2CA2400/T2HB2400
T2CA8400/T2HB8400
T2CA4400/T2HB4400
T3CA9990/T3HB9990
T3CA9920/T3HB9920
T3CA9220/T3HB9220
T3CA2220/T3HB2220
T3CA9980/T3HB9980
T3CA9280/T3HB9280
T3CA9940/T3HB9940
T3CA2280/T3HB2280
T3CA9240/T3HB9240
T3CA2240/T3HB2240
T4CA9999/T4HB9999
T4CA9992/T4HB9992
T4CA9922/T4HB9922
T4CA9222/T4HB9222
T4CA2222/T4HB2222
2
2
2
2
2
3
3
3
3
3
3
3
3
3
3
4
4
4
4
4
27,000 (7.9) / 27,200 (8.0)
36,000 (10.6) / 36,000 (10.5)
34,000 (10) / 35,000 (10.2)
41,000 (12) / 42,000 (12.3)
45,000 (13.2) / 48,000 (14.1)
27,000 (7.9) / 27,800 (8.1)
30,000 (8.8) / 29,800 (8.7)
32,000 (9.4) / 31,800 (9.3)
34,000 (10) / 34,000 (10.0)
36,000 (10.6) / 36,400 (10.7)
39,000 (11.4) / 38,500 (11.3)
41,000 (12) / 42,500 (12.4)
41,000 (12) / 40,500 (11.9)
43,000 (12.6) / 44,500 (13.0)
46,000 (13.5) / 46,500 (13.6)
36,000 (10.6) / 37,200 (10.9)
38,000 (11.1) / 39,000 (11.4)
41,000 (12) / 41,000 (12.0)
42,000 (12.3) / 43,000 (12.6)
45,000 (13.2) / 45,000 (13.2)
N/A / 20,500 (6.0)
N/A / 25,600 (7.5)
N/A / 26,400 (7.7)
N/A / 30,400 (8.9)
N/A / 35,500 (10.4)
N/A / 22,200 (6.5)
N/A / 23,800 (7.0)
N/A / 25,800 (7.6)
N/A / 27,600 (8.1)
N/A / 27,000 (7.9)
N/A / 29,000 (8.5)
N/A / 33,400 (9.8)
N/A / 31,000 (9.1)
N/A / 35,200 (10.3)
N/A / 36,800 (10.8)
N/A / 29,200 (8.5)
N/A / 31,000 (9.1)
N/A / 33,000 (9.7)
N/A / 34,800 (10.2)
N/A / 36,800 (10.8)
●
SYSTEM CAPACITY GUIDE
Example: T2CA9800
Zone 1
Zone 2
Zone 3
Zone 4
9
8
0
0
Individual
Zone
Capacity:
9 = 9,000
2 = 12,000
8 = 18,000
4 = 24,000
Empty Zone = 0
●
●
●
●
●
Standard heating operation down to 0°F (-18°C) outside
temperature for T2HB, T3HB and T4HB
Standard cooling operation down to 60°F (15°C) outside
temperature for T2CA, T3CA and T4CA
Up to 4 fully independent circuits
Enhanced reliability with a compressor on each refrigerant circuit
Application flexibility with standard refrigerant piping of 100'
(16.6 m) interconnect, supporting 35' (30.5 m) of lift
Industry standard R22 refrigerant
Easy access connections for refrigerant gauges
Corrosion resistant, powder-coated steel cabinet
with coil protection
One year parts, five year compressor warranty
Options:
●
●
●
●
●
●
●
●
For T2CA/T2HB units, 2 circuits with nominal capacity
choices of 9,000, 12,000, 18,000 and 24,000 BTUH
(2.6, 3.5, 5.2 and 7.0 kW) are available
For T3CA/T3HB units, 3 circuits with nominal capacity
choices of 9,000, 12,000, 18,000 and 24,000 BTUH
(2.6, 3.5, 5.2 and 7.0 kW) are available
For T4CA/T4HB units, 4 circuits with nominal capacity choices
of 9,000 and 12,000 BTUH (2.6 and 3.5 kW) are available
Low Ambient Kit - field installed for operation down to
32°F (0°C) outside temperature (T2CA, T3CA, T4CA only)
Hard Start Kit - assists compressor start-up under abnormal
conditions such as low voltage (T2CA, T3CA, T4CA only)
115V 9,000 - 12,000 BTUH, (2.6 - 3.5 kW)
Consult factory for availability
Condenser Coil Corrosion Protection Coating
Copper/Copper coils (sea coast use)
— See Model Numbers for Specific Offerings —
For complete product information, please refer to individual unit specifications,
installation and operation manual, and other product literature. Due to on-going
product development, specifications are subject to change without notice.
An ISO 9001-2000 Certified Company
Enviromaster International, LLC
5780 Success Drive • Rome, NY 13440
Phone: 800-325-5479 • Fax: 866-432-7329
E-Mail: emi@enviromaster.com
Web: www.enviromaster.com
USA Contractor Assistance: 800-325-5479
In Canada Contact:
PO Box 900 6800 Base Line,
Wallaceburg, Ontario, Canada N8A 5E5
Ph: 519-627-0791 • Fax: 519-627-4719
E-Mail: info@ecrltd.com
Web: www.ecrltd.com
PN 240004840 Rev. 10/08
Download PDF