INSTRUCTION MANUAL
AUTOMATIC TRACKING PULSE TOTAL STATION
GPT-8000A SERIES
GPT-8001A
GPT-8002A
GPT-8003A
GPT-8005A
SERVO PULSE TOTAL STATION
GPT-8000 SERIES
GPT-8001
GPT-8002
GPT-8003
GPT-8005
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
FOREWORD
FOREWORD
Thank you for purchasing the TOPCON Auto Tracking Pulse Total Station / Servo
Pulse Total Station, GPT-8000A/8000 series. For the best performance of the
instruments, please carefully read these instructions and keep them in a convenient location for future reference.
General Handling Precautions
Before starting work or operation, be sure to check that the instrument is functioning
correctly with normal performance.
Do not submerge the instrument into water.
e
The instrument can not be submerged underwater.
The instrument is designed based on the International Standard IP54, therefore it is protected from
the normal rainfall.
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
Setting the instrument on a tripod
When mounting the instrument on a tripod, use a wooden tripod when possible. The vibrations that
may occur when using a metallic tripod can effect the measuring precision.
Installing the tribrach
If the tribrach is installed incorrectly, the measuring precision could be effected. Occasionally check the
adjusting screws on the tribrach. Make sure the base fixing lever is locked and the base fixing screws
are tightened.
Guarding the instrument against shocks
When transporting the instrument, provide some protection to minimize risk of shocks. Heavy shocks
may cause the measurement to be faulty.
Carrying the instrument
Always carry the instrument by its handgrip.
Exposing the instrument to extreme heat.
Do not leave the instrument in extreme heat for longer than necessary. It could adversely affect its
performance.
Sudden changes of temperature
Any sudden change of temperature to the instrument or prism may result in a reduction of measuring
distance range, i.e when taking the instrument out from a heated vehicle. Let instrument acclimate
itself to ambient temperature.
Battery level check
Confirm battery level remaining before operating.
Memory back up
The instrument has a built in battery for memory back up. If the battery power is low, “Back up battery
empty” will display. Contact your dealer, to replace the battery.
Taking the battery out
It is recommended not to take the battery out during the power is on. All the data stored is possible
gone at that time. So please do your assembling or taking the battery out after the power is off.
No responsibility
TOPCON Corporation has no responsibility for loss of data stored in the memory in case unexpected
accidents.
1
FOREWORD
Rotating the instrument and telescope
Rotation of the instrument or telescope is driven electronically in normal operation.
Do not disturb the rotation.
Storage in the case
Keep the telescope horizontally and turn the instrument to align its mark with the lower base mark
(Storage mark). Keep its objective lens side downward. Storing it in the case in any other way may
cause damage. Hold the hand grips and base with both hands, when taking the instrument out of the
case, or putting the equipment in the case.
Maintenance for driving parts.
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
Every 4,000~5,000 hours operation in total, change grease of driving parts.
Contact your dealer or TOPCON Head Office for the maintenance.
2
FOREWORD
Display for Safe Use
In order to encourage the safe use of products and prevent any danger to the operator and others or
damage to properties, important warnings are put on the products and inserted in the instruction
manuals.
We suggest that everyone understand the meaning of the following displays and icons before reading
the “Safety Cautions” and text
Display
Meaning
WARNING
Ignoring or disregard of this display may lead to the danger of death or
serious injury.
CAUTION
Ignoring or disregard of this display may lead to personal injury or physical damage.
•Injury refers to hurt, burn, electric shock, etc.
•Physical damage refers to extensive damage to buildings or equipment and furniture.
Safety Cautions
e
WARNING
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
•There is a risk of fire, electric shock or physical harm if you attempt to disassemble or
repair the instrument yourself.
This is only to be carried out by TOPCON or an authorized dealer, only!
•Cause eye injury or blindness.
Do not look at the sun through a telescope.
•Laser beams can be dangerous, and can cause eye injury's if used incorrectly.
Never attempt to repair the instrument yourself. (GPT-8000A series and laser plummet model)
•Cause eye injury or blindness.
Do not stare into beam.
(GPT-8000A series and laser plummet model)
•High temperature may cause fire.
Do not cover the charger while it is charging.
•High temperature may cause fire.
Do not connect the battery to an instrument while it is charging.
•Risk of fire or electric shock.
Do not use damaged power cable, plug and socket.
•Risk of fire or electric shock.
Do not use a wet battery or charger.
•May ignite explosively.
Never use an instrument near flammable gas, liquid matter, and do not use in a coal mine.
•Battery can cause explosion or injury.
Do not dispose in fire or heat.
•Risk of fire or electric shock.
Do not use any power voltage except the one given on manufacturers instructions.
•Battery can cause outbreak of fire.
Do not use any other type of charger other than the one specified.
•Risk of fire.
Do not use any other power cable other than the one specified.
•Battery can cause outbreak of fire.
Do not block up the vent of the battery.
•The short circuit of a battery can cause a fire.
Do not short circuit battery when storing it.
3
FOREWORD
CAUTION
Use of controls or adjustment or performance of procedures other than those specified herein
may result in hazardous radiation exposure.(GPT-8000A series and laser plummet model)
Let the laser beam reach the aimed object or the target without anybody else in the laser beam
path. In case you operate laser beam open, avoid radiating laser beam to the height of man's
head. It is quite possible for the beam to enter into one's eyes, and it is possible to lose visual
sight temporarily, and lose one's caution and awareness of other dangers - avoid glaring
beam.(GPT-8000A series and laser plummet model)
Do not connect or disconnect equipment with wet hands, you are at risk of electric shocks if you
do!
Risk of injury by overturn the carrying case.
Do not stand or sit on the carrying cases.
e
Please note that the tips of tripod can be hazardous, be aware of this when setting up or carrying
the tripod.
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
Risk of injury by falling down the instrument or case.
Do not use a carrying case with a damaged which belts, grips or latches.
Do not allow skin or clothing to come into contact with acid from the batteries, if this does occur
then wash off with copious amounts of water and seek medical advice.
A plumb bob can cause an injury to a person if used incorrectly.
It could be dangerous if the instrument falls over, please ensure you attach a handle battery to
the instrument securely.
Ensure that you mount the Tribrach correctly, failing to do so may result in injury if the tribrach
were to fall over.
It could be dangerous if the instrument falls over, please check that you fix the instrument to the
tripod correctly.
Risk of injury by falling down a tripod and an instrument.
Always check that the screws of tripod are tightened.
User
1)This product is for professional use only!
The user is required to be a qualified surveyor or have a good knowledge of surveying, in order to
understand the user and safety instructions, before operating, inspecting or adjusting.
2)Wear the required protectors (safety shoes, helmet, etc.) when operating.
Exceptions from Responsibility
1)The user of this product is expected to follow all operating instructions and make periodic checks of the
product’s performance.
2)The manufacturer, or its representatives, assumes no responsibility for results of a faulty or intentional
usage or misuse including any direct, indirect, consequential damage, and loss of profits.
3)The manufacturer, or its representatives, assumes no responsibility for consequential damage, and
loss of profits by any disaster, (an earthquake, storms, floods etc.).
A fire, accident, or an act of a third party and/or a usage any other usual conditions.
4)The manufacturer, or its representatives, assumes no responsibility for any damage, and loss of profits
due to a change of data, loss of data, an interruption of business etc., caused by using the product or
an unusable product.
5)The manufacturer, or its representatives, assumes no responsibility for any damage, and loss of profits
caused by usage except for explained in the user manual.
6)The manufacturer, or its representatives, assumes no responsibility for damage caused by wrong
movement, or action due to connecting with other products.
4
FOREWORD
Laser Safety
● Distance measurement
GPT-8000A/8000 series uses the invisible laser beam to measure the distance. The GPT-8000A/8000
series are manufactured and sold in accordance with "Performance Standards for Light-Emitting
Products" (FDA/BRH 21 CFR 1040) or "Radiation Safety of Laser Products, Equipment Classification,
Requirements and User`s Guide" (IEC Publication 60825-1) provided on the safety standard for laser
beam.
As per the said standard, the GPT-8000 series is classified as "Class 1 (l) Laser Products".
In case of any failure, do not disassemble the instrument. Contact TOPCON or your TOPCON dealer.
● GPT-8000A series
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
GPT-8000A series uses the visible laser beam for auto tracking and optical communication. The GPT8000A series products are manufactured and sold in accordance with “Radiation Safety of Laser
Products, Equipment Classification, Requirements and User‘s Guide” (IEC Publication 60825-1) or
“Performance Standards for Light-Emitting Products” (FDA/BRH 21 CFR 1040) provided on the safety
standards for laser beam.
As per the said standards, GPT-8000A series is classified as “Class 2 (CLASS II) Laser Products”.
The laser beam belongs not very dangerous type but we request you to keep and understand “Safety
standard for users” as mentioned in the manual instruction.
In case of any failure, do not disassemble the instrument. Contact TOPCON or your TOPCON dealer.
Labels
Find the labels which describes the caution and safety about the laser beam as follows in GPT-8000A
series. We request you to replace it one anytime the caution labels are damaged or lost and paste a
new one at the same place. You can get the labels fromTopcon or your dealer.
Beam aperture
Warning Label
Beam aperture
Explanatory Label
CAUTION
LASER RADIATION
DO NOT STARE INTO BEAM
Maximum output 1mW Wave length 690nm CW
CLASS 2 LASER PRODUCT
GPT-8000A series
Each label is differed by the market.
Symbol marks while the laser is emitting.
The following symbol marks of instrument status will indicate that the laser is emitting.
Marks
V : 87°55'45"
HR: 180°44'12"
Status of instrument
Auto-collimating
Auto-tracking
SD
HD
NEZ
0SET
HOLD
P1↓
Waiting
The symbol mark
Searching
5
FOREWORD
● Laser plummet model
GPT-8000A/8000 series Laser plummet model use a visible laser beam to perform the plumb laser
function. The GPT-8000A/8000 series Laser plummet type products are manufactured and sold in
accordance with "Radiation Safety of Laser Products, Equipment Classification, Requirements and
User`s Guide" (IEC Publication 60825-1) or "Performance Standards for Light-Emitting Products" (FDA/
BRH 21 CFR 1040) regarding the safety standard for laser products.
As per these standards, the GPT-8000A/8000 series Laser plummet type is classified as "Class II (2)
Laser Products".
Since Laser radiation is emitted from the GPT-8000A/8000 series Laser plummet type instruments,
please refer to the "Laser Safety" bulletin which accompanies the instrument in the United States as
well as the "Safety Standard for Users" that is mentioned in the instruction manual.
In the case of any technical failure, do not disassemble the instrument. Contact either TOPCON or your
authorized TOPCON dealer.
Labels
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
The following labels are found on the instruments which describe the GPT-8000A/8000 series Laser
plummet type: Precautions and safety information about the laser beam.
If, at any time, any of these labels are damaged and become illegible, please replace these important
labels. Please the new labels in exactly the same position as the original labels.
Replacement labels can be obtained from Topcon or your authorized Topcon dealer.
Warning Label
GPT-8000A/8000 series
Laser Plummet type
Explanatory Label
CAUTION
LASER RADIATION-DO NOT
STARE INTO BEAM
WAVE LENGTH 633nm
1mW MAXIMUM OUTPUT
CLASS II LASER PRODUCT
Aperture Label
AVOID EXPOSURE
LASER LIGHT IS EMITTED
FROM THIS APERTURE
LASER RADIATION
DO NOT STARE INTO BEAM
Maximum output 1mW Wave length 633nm
CLASS 2
LASER PRODUCT
Beam aperture
Depending on the country where the instrument is sold, either of these labels may be
found on the GPT-8000A/8000 series laser plummet type.
Symbol mark while the laser is emitting.
The following symbol mark will appear at the right side of the second line.
V : 87°55'45"5
HR: 180°44'12"5
The symbol mark will blink while the laser
plummet is working
SD
HD
NEZ
0SET
HOLD
P1↓
6
FOREWORD
Contents
FOREWORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
General Handling Precautions . . . . . . . . . . . . . . . . . . . . . . 1
Display for Safe Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Safety Cautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
User . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Exceptions from Responsibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Laser Safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Standard Set Composition. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
1 NOMENCLATURE AND FUNCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
Operating Key. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
Function Key (Soft Key) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
Star key mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7
Auto Power Off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-12
Data Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-12
Rotating Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-12
1.8.1 Rotating by H/V Shuttle and H/V Jog. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-12
1.8.2 Auto Inversion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-12
1.8.3 Rotating automatically to a required Horizontal and Vertical angle . . . . . . . . . . 1-13
1.9 Using together with RC-2II Remote Control System
(GPT-8000A series) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-14
1.10 Using connecting with Personal Computer (PC). . . . . . . . . . . . . . . . . . . . . . . . . . . 1-15
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
1.1
1.2
1.3
1.4
1.5
1.6
1.7
1.8
2 PREPARATION FOR MEASUREMENT . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
2.1 Power Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
2.2 Setting Instrument Up For Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
2.3 Power Switch Key ON . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
2.4 Battery Level Indicator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
2.5 Main Menu Icons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
2.6 Vertical and Horizontal Angle Tilt Correction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6
2.7 Compensation of Systematic Error of Instrument. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7
2.8 Resume Mode ON/OFF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8
2.9 How to Enter Numerals and Alphabet Letters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8
2.10 Memory Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-9
2.11 Inclination of Prism and Measuring Error (GPT-8000A series). . . . . . . . . . . . . . . . . 2-10
3 AUTOMATIC TRACKING / AUTOMATIC COLLIMATION
(GPT-8000A series) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.1
3.2
3.3
3.4
Automatic Tracking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Automatic Collimation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Range of Laser for Auto-tracking and Auto-collimating . . . . . . . . . . . . . . . . . . . . . . . .
Setting Parameters for Auto-Tracking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.4.1 Setting Items . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.4.2 How to set the parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-1
3-1
3-3
3-4
3-5
3-5
3-7
4 STANDARD MEASUREMENT MODE . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
4.1 Angle Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
4.1.1 Measuring Horizontal Angle Right and Vertical Angle . . . . . . . . . . . . . . . . . . . . . 4-1
4.1.2 Switching Horizontal Angle Right/Left . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2
4.1.3 Measuring from the Required Horizontal Angle . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2
4.1.4 Vertical Angle Percent Grade(%) Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3
4.1.5 Automatic Rotation to a Required Horizontal and Vertical Absolute Angle . . . . . 4-4
4.2 Distance Measurement . . . . . . . . . . . . . . . . . . . . . . 4-5
4.2.1 Setting of the Atmospheric Correction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5
4.2.2 Setting of the Correction for Prism Constant / Non-prism Constant. . . . . . . . . . . 4-5
4.2.3 Distance Measurement (Continuous Measurement) . . . . . . . . . . . . . . . . . . . . . . 4-6
4.2.4 Distance Measurement (Single/N-times Measurement) . . . . . . . . . . . . . . . . . . . 4-7
4.2.5 Fine / Coarse Measuring Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-9
4.2.6 Stake Out (S-O) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-10
4.3 COORDINATE MEASUREMENT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-11
7
FOREWORD
4.3.1 Setting Coordinate Values of Occupied Point . . . . . . . . . . . . . . . . . . . . . . . . . .
4.3.2 Setting of the Instrument Height / Prism Height . . . . . . . . . . . . . . . . . . . . . . . . .
4.3.3 Execution of Coordinate Measuring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.4 DATA OUTPUT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-11
4-13
4-14
4-16
5 PROGRAM MODES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1
5.1
5.2
5.3
5.4
5.5
5.6
Setting a Direction Angle for Backsight Orientation . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2
Retaining a Coordinate (STORE- NEZ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3
Remote Elevation measurement (REM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-5
Missing Line Measurement (MLM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-8
Line Measurement (LINE). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-11
Offset measurement (OFFSET) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-14
5.6.1 Angle Offset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-15
5.6.2 Distance Offset Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-17
5.6.3 Plane Offset Measurement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-19
5.6.4 Column Offset Measurement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-21
5.7 External Link (GPT-8000A series) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-23
5.7.1 Starting compatible communication program of AP-L1A . . . . . . . . . . . . . . . . . . 5-23
5.7.2 Setting for the communication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-23
5.7.3 Carrying out Communication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-27
View Internal Memory and Card Memory Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1
Protect a File. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2
Rename a File. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2
Deleting a File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-3
Copy a File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-3
Initializing Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-4
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
6.1
6.2
6.3
6.4
6.5
6.6
e
6 MEMORY MANAGE MODES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1
7 COMMUNICATION MODES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1
7.1 Setting of PROTOCOL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1
7.2 Data File In . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-2
7.3 Data File Out. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-2
8 PARAMETERS SETTING MODE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-1
8.1 Parameter Setting Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8.1.1 Parameters for Measurement and Display. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8.1.2 Parameters for communication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8.2 Setting Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8.2.1 Parameters for Measurement and Display. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8.2.2 Parameters for Communication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8.2.3 Password Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8-1
8-1
8-2
8-4
8-4
8-5
8-6
9 CHECK AND ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-1
9.1 Checking and Adjusting of Instrument Constant. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-1
9.1.1 Checking of the accuracy of the non-prism mode . . . . . . . . . . . . . . . . . . . . . . . . 9-1
9.2 Checking the Optical Axis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-2
9.3 Checking/Adjusting the Theodolite Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-4
9.3.1 Checking /Adjusting the Plate Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-5
9.3.2 Checking /Adjusting the Circular Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-5
9.3.3 Adjustment of the Vertical Cross-hair. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-6
9.3.4 Collimation of the Instrument. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-7
9.3.5 Checking / Adjusting the Optical Plummet Telescope. . . . . . . . . . . . . . . . . . . . . 9-8
9.3.6 Checking / Adjusting the Laser Plummet (For Laser Plummet type) . . . . . . . . . . 9-9
9.4 Adjustment of Compensation Systematic Error of Instrument . . . . . . . . . . . . . . . . . . 9-10
9.5 Showing Constant List and Switch ON/OFF
Compensation Systematic Error of Instrument . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-12
9.6 How to adjust the date and time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-13
9.7 How to Set the Instrument Constant Value. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-14
9.8 Inspection and Adjustment of Optic Axis for Auto -Tracking
(GPT-8000A Series) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-15
10 SETTING THE PRISM / NON-PRISM CONSTANT VALUE . . . . . . . . 10-1
11 SETTING ATMOSPHERIC CORRECTION . . . . . . . . . . . . . . . . . . . . . 11-1
11.1 Calculation of Atmospheric Correction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-1
11.2 Setting of Atmospheric Correction Value . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-1
8
FOREWORD
12 CORRECTION FOR REFRACTION AND EARTH CURVATURE . . . 12-1
12.1 Distance Calculation Formula. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12-1
13 POWER SOURCE AND CHARGING . . . . . . . . . . . . . . . . . . . . . . . . . 13-1
13.1 Rechargeable Battery BT-56Q . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13-1
14 DETACH/ATTACH OF TRIBRACH. . . . . . . . . . . . . . . . . . . . . . . . . . . 14-1
15 BATTERY SYSTEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15-1
16 PRISM SYSTEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16-1
17 PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17-1
18 ERROR DISPLAYS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18-1
19 SPECIAL ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19-1
20 SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20-1
APPENDIX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . APPENDIX-1
e
Dual Axis Compensation .................................................................................... APPENDIX-1
Precaution when Charging or Storing Batteries.................................................. APPENDIX-3
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
Standard Set Composition
1) GPT-8000A/8000 series (with lens cap). . . . . . . . . . . . . . . . . . . . . . . . . 1 each
2) Battery BT-56Q . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 each
3) Battery charger BC-27BR or BC-27CR . . . . . . . . . . . . . . . . . . . . . . . . . 1 each
4) Tool kit with case [ rod pins, screwdriver, cleaning brush ] . . . . . . . . . . . 1 set
5) Plastic carrying case . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 each
6) Silicon cloth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 each
7) Plastic rain cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 each
8) Instruction manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 each
(Make sure that all of the above items are with the instrument when purchased.)
Remarks:
1) Battery charger BC-27CR is for AC 230V use and BC-27BR is for AC 120V use.
2) Plumb bob set and plumb bob hook are supplied for certain markets.
9
1 NOMENCLATURE AND FUNCTIONS
1
NOMENCLATURE AND FUNCTIONS
1.1 Nomenclature
Handle
Sighting collimator
Handle fixing knob
Laser aperture
(for optical
communication)
(GPT-8000A series)
Instrument height
mark
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
Objective lens
Laser aperture
(for auto-tracking)
(GPT-8000A series)
Tracking indicator
(GPT-8000A series)
Point guide
(GPT-8000 series)
Optical plummet
telescope
Display window
Instrument center
mark
Card cover lever
Battery BT-56Q
Power supply
connector
Operation keys
Serial Signal
Connector-1(6pin)
Leveling screw
Base (Model 5)
Base fixing screw
The caution labels are pasted up GPT-8000A series and Laser plummet model which describe
the warning of laser beam.
Refer to "Laser Safety" and "Laser plummet model" about label positions and their shapes.
1-1
1 NOMENCLATURE AND FUNCTIONS
Battery fixing knob
Telescope
focusing knob
Instrument height
mark
Telescope grip
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
Instrument center
mark
Vertical shuttle
Telescope eyepiece
Plate level
Vertical jog
Power switch
Horizontal shuttle
Horizontal jog
Centronics
connector
Circular level
Tribrach fixing lever
Adjusting screws for
circular level
1-2
1 NOMENCLATURE AND FUNCTIONS
1.2 Display
● Display
In general upper four lines display the measuring data, and the bottom line displays the soft key
function which is changed by the measuring mode.
● Contrast
The contrast and illumination of display window are adjusted by star (★) key.
● Heater (Automatic)
The built-in heater keeps the display functional when the temperature goes below 0°C (32 °F). To
switch the heater ON or OFF, refer to Chapter 8 “PARAMETERS SETTING MODE”.
When the heater is ON and the temperature goes below 0°C (32 °F), the heater automatically
adjust the temperature to the display to keep it operating.
● Example
V : 87°55'45"
HR: 180°44'12"
SD
HD
NEZ
V : 87°55'40"
HR: 180°44'12"
SD:
12.345
0SET
HOLD
P1↓
MEAS
VH
Distance measurement mode
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
Angle measurement mode
MODE
V-angle
H-angle
:
PSM 0.0
PPM
0.0
(m) *F.R
HD NEZ P1 ↓
87°55’20”
:180°44’12”
Horizontal-angle
87°55’40”
:
Horizontal distance : 180°44’12”
Relative elevation :12.345m
● Display marks
Display
Contents
Display
Content
V-angle
(m)
Meter unit
Percent grade
(f)
Feet unit
H-angle right
F
Fine mode
H-angle left
C
Coarse mode (1mm)
Horizontal distance
c
Coarse mode (10mm)
Relative elevation
R
Repeat measurement
Slope distance
S
Single measurement
N
N coordinate
N
N-times measurement
E
E coordinate
ppm
Atmospheric correction value
Z
Z coordinate
PSM
Prism constant value
*
EDM working
NPM
Non-Prism constant value
NP
Non-prism mode
V
V%
HR
HL
HD
VD
SD
Battery Level Indicator
Refer to Section 2.4 “Battery Level
Indicator” for further information.
Rotation Indicator
Refer to Section 1.8 “Rotating
Method” for further information.
Laser plummet is working.
(Only for laser plummet model)
1-3
1 NOMENCLATURE AND FUNCTIONS
● The symbol marks for Auto-tracking and Auto-collimating (GPT-8000A series)
Auto-collimating
(Laser is emitting)
GPT-8000A series is in autocollimating status.
Auto-tracking
(Laser is emitting)
GPT-8000A series is in autotracking status.
Waiting (Laser is emitting)
GPT-8000A series is in waiting
status.
Searching (Laser is emitting)
GPT-8000A series is searching
a prism.
Failure in auto-collimating.
(Laser is off)
GPT-8000A series could not find
the target prism during autocollimating.
e
Operating Key
KEY
F1~F6
0~9 . A ~/
ESC
ENT
POWER
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
1.3
NAME
FUNCTION
Soft key
Functions are according to the displayed message.
Numeric key
Numeric Character Entry for Preset Data
Alpha key
Alpha Character Entry
Escape key
Escape to Previous Display or Menu
Star key
Optional instrument functions
Enter key
End operation of data input and accepts data
Power key
ON/OFF of power source.
(Power key is located on the side of the instrument.)
1-4
1 NOMENCLATURE AND FUNCTIONS
1.4 Function Key (Soft Key)
The Soft Key Functions are labeled on the bottom of display. Soft Key functions are different for each
measurement.
V : 87°55'45"5
HR: 180°44'12"5
SD
HD
[F1]
NEZ
[F2]
[F3]
0SET HOLD
[F4]
P1↓
[F5]
[F6]
Soft keys
HD
HOLD P1↓
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
SD
V : 90°10'20"5
HR: 120°30'40"5
SD:
e
V : 87°55'45"5
HR: 180°44'12"5
NEZ
0SET
TURN HSET R/L
MEAS
V/% TILT P2↓
MODE
TURN
V : 90 10'20"5
HR: 120 30'40"5 PSM
0.0
HD:
PPM
0.0
VD:
(m) F.R
MEAS MODE VH SD NEZ P1↓
SO
MEAN
Angle
measuring
Display
Soft
key
SD
HD
NEZ
0SET
HOLD
TURN
HSET
R/L
V/%
F1
F2
F3
F4
F5
F1
F2
F3
F4
TILT
F5
MEAN
N : 12345.6789
E : -12345.6789
Z :
10.1234
MEAS MODE VH
P2↓
TURN
m/ft
P2↓
HT
SD
PSM 0.0
PPM 0.0
(m) F.R
HD P1↓
MEAN
Coordinate measuring
Horizontal distance measuring
Page
SO
Slope distance measuring
Angle measuring
REC
VH
PSM 0.0
PPM 0.0
(m) F.R
HD NEZ P1↓
Function
Slope distance measuring mode.
Horizontal distance measuring mode.
Coordinate distance measuring mode.
Set horizontal angle to 0°00'00".
Horizontal angle hold.
Turns the instrument to required angle automatically.
Preset a horizontal angle.
Changes horizontal angle right or left.
Changes the display to vertical angle or percent of grade.
Sets the tilt function, ON/OFF.
If ON, the display shows tilt correction value.
1-5
P2↓
1 NOMENCLATURE AND FUNCTIONS
Horizontal
distance
measuring
Coordinate
measuring
Soft
key
MEAS
F1
MODE
VH
F2
F3
HD
F4
NEZ
F5
TURN
SO
MEAN
m/ft
F1
F2
F3
F4
MEAS
F1
MODE
VH
F2
F3
SD
F4
NEZ
F5
TURN
SO
MEAN
m/ft
F1
F2
F3
F4
MEAS
F1
MODE
VH
F2
F3
SD
F4
HD
F5
TURN
HT
MEAN
m/ft
SET
F1
F2
F3
F4
F5
Function
Starts slope distance measurement mode.
Changes Continuous/ N-times (single) measurement mode.
Changes Fine / Coarse(1mm) /Coarse(10mm) mode.
Angle measurement mode.
Horizontal distance measurement mode. Displays the horizontal distance
data after N-times or single measurement.
Coordinate measurement mode.
Displays the coordinate after N-times or single measurement.
Turns the instrument to required angle automatically.
Stake out measurement mode.
Sets the number of N-time measurement.
Changes distance measurement unit to meter or feet.
Starts horizontal distance measurement mode.
Changes continuous/ N-times (single) measurement mode.
Changes Fine / Coarse(1mm) /Coarse(10mm) mode.
Angle measurement mode.
Slope distance measuring mode.
Display the slope distance after N-times or single measurement.
Coordinate measurement mode.
Displays the coordinate after N-times or single measurement.
Turns the instrument to required angle automatically.
Stake out measurement mode.
Sets the number of N-time measurement.
Switches meter or feet unit.
Starts coordinate measurement mode.
Changes continuous/ N-times (single) measurement mode.
Changes Fine / Coarse(1mm) /Coarse(10mm) mode.
Angle measurement mode.
Slope distance measuring mode.
Display the slope distance after N-times or single measurement.
Horizontal distance measurement mode. Displays the horizontal distance
data after N-times or single measurement.
e
Slope
distance
measuring
Display
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
Page
Turns the instrument to required angle automatically.
Input Instrument / prism height values.
Sets the number of N-time measurement.
Switches meter or feet unit.
Pre-set instrument coordinate values.
1-6
1 NOMENCLATURE AND FUNCTIONS
1.5 Star key mode
Press the (
) key to view the instrument options. Since there are three screens (GPT-8000A series)
or two screens (GPT-8000 series) of options, press [F6](1 ↓) soft key to view the next screen.
The following instrument options can be selected from the (
):
GPT-8000A series
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
● Screen One
1) View Date & Time
2) Auto-tracking [F1]
3) Auto-collimating [F2]
4) Set the parameters for Auto-tracking.[F3]
5) Auto- inversion [F4]
6) Non-prism mode / Prism mode selection [F5]
● Screen Two
7) Adjustment the contrast of the display [F1 & F2]
8) Turn the back light of the display ON/OFF [F3]
9) Reticle illumination---Off / Low / Medium / High [F4]
10) View free memory for internal and card memory [F5]
● Screen Three
11) The light acceptance quantity level (signal level) is displayed.[F1]
12) Set the Temperature, Pressure, Atmospheric Correction Value (PPM), and Prism Constant
Value (PSM) [F2]
13) Turn the Tracking Indicator option ON/OFF [F3]
14) Electric circular graphic display[F5]
15) Turn the Laser plummet option ON/OFF [F5] (only for Laser plummet model)
Set parameter for Auto-tracking
Auto-tracking
Date & Time
Auto- inversion
Auto-collimating
2002-07-07
Non-prism/ Prism
mode
14:30:40
NP/P
Screen 1
1↓
View free memory for Card/Internal Memory
Contrast adjustment
Back Light of Display
Reticle illumination
2002-07-07
14:30:40
Screen 2
2↓
Displaying
Signal Level
Set the Temperature, Pressure, Atmospheric Correction
Value (PPM), and Prism Constant Value (PSM)
Tracking indicator
2002-07-07
Laser Plummet
(Only for Laser Plummet type)
14:30:40
Screen 3
3↓
Electric circular graphic display
1-7
1 NOMENCLATURE AND FUNCTIONS
GPT-8000 series
● Screen One
1) View Date & Time
2) Electric circular graphic display[F1]
3) The light acceptance quantity level (signal level) is displayed.[F2]
4) Set the Temperature, Pressure, Atmospheric Correction Value (PPM), and Prism Constant
Value (PSM) [F3]
5) Auto- inversion [F4]
6) Non-prism mode / Prism mode selection [F5]
● Screen Two
7) Adjustment the contrast of the display [F1 & F2]
8) Turn the back light of the display ON/OFF [F3]
9) Reticle illumination---Off / Low / Medium / High [F4]
10) View free memory for internal and card memory [F5]
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
● Screen three
11) Turn the Point Guide option ON/OFF [F1]
12) Turn the Laser plummet option ON/OFF [F1] (only for Laser plummet model)
Electric circular graphic display
Auto- inversion
Displaying Signal Level
Date & Time
Non-prism/ Prism mode
2002-07-07 14:30:40
NP/P
Screen 1
1↓
Set the Temperature, Pressure, Atmospheric Correction
Value (PPM), and Prism Constant Value (PSM)
Back Light of Display
Reticle
illumination
Contrast adjustment
View free memory for the Card/Internal Memory
2002-07-07 14:30:40
Screen 2
2↓
● Only for Laser Plummet type
Point guide
2001-07-10 14:30:40
Screen 3
3↓
Laser Plummet
(Only for Laser Plummet type)
1-8
1 NOMENCLATURE AND FUNCTIONS
1) View Date & Time
The date and time can be viewed on both screens.To change the displayed order of the date, (Date/
Month/Year), (Month / Date / Year) or (Year/Month/Date), see Chapter 8 “PARAMETERS SETTING
MODE” .
To set the date and time, see Chapter 9 “CHECK AND ADJUSTMENT”.
2) Turn the auto-tracking ON/OFF (GPT-8000A series)
Press the [F1] key to start auto-tracking. See Section 3.1 “Automatic Tracking” .
3) Turn the auto-collimating ON/OFF (GPT-8000A series)
Press the [F2] key to start auto-collimating. See Section 3.2 “ Automatic Collimation” .
4) Set the parameters for the auto-tracking (GPT-8000A series)
A proper setting for each parameter such as tracking pattern, tracking range, waiting time, tracking
speed and tracking sensitivity. See Section 3.4 “Setting Parameters for Auto-Tracking” .
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
5) Auto Inversion
Pressing the [F4] key causes the instrument to reverse and turn the telescope and instrument
automatically.
● To stop auto rotating in case of emergency, press any keys except POWER key.
● During auto rotation, do not disturb the instrument.(Stopping the rotation with a touch of the hand).
Such action may cause trouble or harm to instrument or operator.
6) Adjustment the contrast of the display
This enable you to adjust the contrast of the display.
Press the [F6] key to get to Screen 2 on the display.
Press the [F1] or [F2] key to brighten or dim the display.
7) Turn the display back light ON/OFF
When the back light is OFF, the light bulb icon is dark.
Press the [F6] key to get to Screen 2 on the display.
To turn the back light ON, press the [F3] key. Press [F3] again to turn the back light OFF.
OFF
ON
8) Reticle illumination (OFF/Low/Middle/High)
Press the [F6] key to get to Screen 2 on the display. Press the [F4] key to turn the reticle illumination
ON. Continuing to press [F4] will change the intensity options.
OFF
Low
Middle
High
9) View free memory
The amount of free memory for the card or internal memory can be displayed.
Press the [F6] key to get to Screen 2 on the display.
Press the [F5] key to view free memory.
The card memory icon (top left side of the display) shows the size of the card and the amount of free
memory. The second icon shows the amount of free internal memory.
Card Memory
512KB
315KByte
1882KByte
Internal Memory
See Chapter 6 “MEMORY MANAGE MODES”, for further options and instructions.
1-9
1 NOMENCLATURE AND FUNCTIONS
10) Set audio mode
The light acceptance quantity level (Signal level) is displayed in this mode.
When reflected light from the prism is received, a buzzer sounds. This function is good for easy
collimation when the target is difficult to find.
Press the [F1] key on screen 3 (GPT-8000A series) or [F2] key on screen 1 (GPT-8000 series).
The received return signal level is displayed with bar graph as follows.
No light acceptance
Maximum quantity level
Minimum quantity level
(1) To stop the buzzer, see Chapter 8 “PARAMETERS SETTING MODE”.
(2) Also, it is possible to display the signal level in Distance Measuring Mode.
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
11) Setting Temperature, Pressure, Atmospheric correction value (PPM), Prism constant value
(PSM)
The temperature, pressure, PPM, and PSM can be viewed by pressing the [F2] key on screen 3 (GPT8000A series) or [F3] key on screen 1 (GPT-8000 series).
The received return signal level is displayed with bar graph as follows.
Refer to Chapter 10 “SETTING THE PRISM / NON-PRISM CONSTANT VALUE ” and Chapter 11
“SETTING ATMOSPHERIC CORRECTION”, for further instructions.
12) Tracking Indicator (GPT-8000A series)
A man who is staying on line with the direction of GPT-8000A series or automatic tracking status by
emitted LED light (orange color) from GPT-8000A series.
● Operation
Pressing [F3] key on the screen three functions Tracking Indicator. The tracking indicator status will be
changed according to the type of auto tracking mode and its conditions. A man from the prism side can
recognize the status of instrument.
When angle measuring value turns stable during tracking still object, the tracking indicator changes
from quick continuous flashing to quick intermittent flashing. So you can decide from the sign of flashing
for recording data timing at one person surveying.
OFF
ON
Meaning of Tracking Indicator ON or Flashing
Tracking Indicator
Status of instrument
Continuous ON
Wait status
Slow flashing
Manual mode
Quick continuous flashing
In case angle measuring value is instable during auto tracking mode.
Quick intermittent flashing
In case angle measuring value is stable during auto tracking mode.
● The function of theTracking Indicator will
be used as a guide to know the status of
GPT-8000A series from the prism side.
This is not a function to determine
precise collimating for measuring.
● The quality of its results will depend on
the weather conditions and the use's
eyesight.
● Sometimes happens difficulty of seeing
the tracking indicator because too much
bright of the beam for tracking.
● Using Tracking Indicator mode will result
shorter in reduced time out of the
battery.
1-10
1 NOMENCLATURE AND FUNCTIONS
13)Point-guide (Point guide type of GPT-8000 series only)
This feature is most useful when doing stake out work. The Point Guide's red LEDs on the GPT-8000
Series telescope assist the rod person in getting on-line. The Point Guide feature is fast and simple to
use.
● Operating Instructions
Press the [F1] key on the screen three to turn ON the Point Guide LEDs. The Point guide icon on the
display will become bright when turned ON. Looking the objective lens of the telescope, the right LED
will blink and the left LED will stay lit.
Instrument
ON
Illuminate
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
The Point Guide should be used within a distance
of 100 meters (328 ft.). The quality of its results
will depend on the weather conditions and the
use's eyesight.
The goal of the rod person is to look at both LEDs
on the instrument and move the prism on-line until
both LEDs become equally bright . If the solid LED
is brighter, move to the right. If the blinking LED is
brighter, move to the left.
e
OFF
Blink
Prism
14) Electric circular level graphic display
Electric circular level can be displayed by graphic. This function is good for level the instrument when
the circular level is difficult to see directly.
Press the [F4](GPT-8000A series) on the screen three or [F1] (GPT-8000 series) on the screen one key
to display the graphic.
In the displays of reverse side, the graphic bubble moves in reverse.
X:00°00'00"
Y:00°00'00"
X:------------Y:-------------
Rotate the leveling screws while observing the display.
After leveling, press [F1]. The display changes to the previous mode.
1-11
1 NOMENCLATURE AND FUNCTIONS
15) Laser Plummet (Only for Laser Plummet type)
Laser plummet option will help you to center the instrument easily onto the measurement point.
Press the star key to view the instrument options. Since there are three screens of options, press
[F6](↓) soft key twice to view the screen 3.
Press the [F1] key (GPT-8000 series) or [F5] key (GPT-8000A series) to turn on/off of laser plummet
option.
Laser plummet icon will change as follows.
OFF
ON
Symbol mark while the laser is emitting.
The following symbol mark will indicate that the laser is emitting.
V : 87°55'45"5
HR: 180°44'12"5
HD
NEZ
0SET
HOLD P1↓
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
SD
e
The symbol mark will blink while the laser
plummet is working
Laser Plummet auto-cut off function
The laser plummet will be turned off automatically after 1 to 99 minutes (Default:3 minutes). It is
also possible to stop the auto-cut off function.
Refer to Chapter 8 “PARAMETERS SETTING MODE” to change the time or to invalidate the
function.
1.6
Auto Power Off
The Auto Power OFF feature can be set from 1 to 99 minutes. If no keys are pressed within the set time,
the Auto Power OFF will automatically turn the instrument OFF in order to save the battery time.
See Chapter 8 “PARAMETERS SETTING MODE”, for further instructions.
1.7
Data Output
When GPT-8000A/8000 series receives data output command from an external
connected device, the measured data will be output by GPT-8000A/8000 series. Select
from the following 2 ways for the output. (For setting, see Chapter 8 “PARAMETERS
SETTING MODE” .)
REC-A : The measurement is started and new data is output.
REC-B : The data being displayed is output.
1.8
Rotating Method
1.8.1 Rotating by H/V Shuttle and H/V Jog
H/V shuttle or H/V jog can be used to rotate the instrument manually. The shuttle movement or
displacement is proportional in speed and size of angle desired. A small, slow turn of the shuttle will
result in a slow small angle displaced. Likewise, a larger abrupt turn of the shuttle will result in a coarse
angle displacement. H/V jog can be used for accurate collimating of the target much like a standard
tangent screw.
1.8.2 Auto Inversion
Pressing the [F4] key in Star Key mode causes the instrument to reverse and turn the telescope and
instrument automatically.
● To stop auto rotating by auto inversion key in case of emergency, press any keys except POWER
key.
1-12
1 NOMENCLATURE AND FUNCTIONS
● During auto rotation, don't disturb the instrument.(Stopping the rotation with a touch of the hand).
Such action may cause trouble or harm to instrument or operator.
See Section 1.5 “Star key mode” for further instructions.
1.8.3 Rotating automatically to a required Horizontal and Vertical angle
In Standard Measurement Modes, the instrument can be rotated automatically by input a required
horizontal and/or vertical angle.
For further instructions, see Section 4.1.5 “Automatic Rotation to a Required Horizontal and Vertical
Absolute Angle” .
This mark will appear while the
instrument is rotating automatically.
V : 87°55'45"5
HR: 180°44'12"5
SD
HD
NEZ
0SET
HOLD P1↓
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
● Attaching Precaution Label
Attach 4 precaution labels to the instrument in specified places to avoid the unexpected accident such
as pinching fingers between telescope and body of instrument or telescope and hand grip during
automatic rotation.
Caution label
CAUTION
Do not place fingers near
telescope during rotation.
● Attach upper side of telescope and near the plate level.
Caution label
1-13
Caution label
1 NOMENCLATURE AND FUNCTIONS
1.9
Using together with RC-2II Remote Control System
(GPT-8000A series)
Using together with RC-2II Remote Control System makes it possible to optical communicate between
the instrument and remote controller RC-2II, the prism side. This gives easy operation by one man
surveying in applying programs.
Also connecting data collector to remote controller, you can manage communication reciprocally
between the instrument and direct to data collector.
Turn-round function
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
You can turn the GPT-8000A series round to the remote controller RC-2II side easily by [Turn-round]
key of the remote controller RC-2II. This function helps to increase one man surveying efficiency.
RC-2II
See to Section 5.7 “External Link (GPT-8000A series)” and Chapter 8 “PARAMETERS SETTING
MODE” for further information.
● Set the transmit path to " RC".
● Set the transmit channel same as RC-2II side.
● To execute transmission, set the remote in Programs mode to [Remote].
1-14
1 NOMENCLATURE AND FUNCTIONS
1.10 Using connecting with Personal Computer (PC)
Commands for tracking mode correspond only to GPT-8000A series.
The auto-tracking function or auto collimating function makes easy remote control of the instrument
from PC. The followings are the main communication commands and explanations. How to
communicate or more informations of communication command, you can see the interface manual
which provided optionally.
Commands
Mode setting
Action
Each measured data will be out put
according to the command type.
Transmit command for tracking mode
The status of Automatic Tracking mode
will be out put.
Transmit command for battery level
The battery level will be out put.
Transmit command for coordinate of
instrument point
Setting coordinate of instrument point will
be out put.
Transmit command for tracking
parameter
Each setting tracking parameter of
instrument will be out put according to the
command type.
Setting of angle measurement
Each selecting mode in horizontal angle
or angle measurement can be decided
according to the purpose of command.
Setting of distance measurement
Setting the measurement mode for
distance measurement.
Setting coordinate of instrument point
Setting the coordinate of instrument point.
Setting the tracking parameter
Setting each tracking parameter
according to the command.
T.I. ON / OFF
ON / OFF of Tracking indicator.
Rotating command
Rotating of setting angle.
Inversion
Inversion movement.
Setting tracking mode
Setting from automatic tracking mode to
each command mode.
e
Transmit command for measured data
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
Transmit
command
Action of GPT-8000A series
1-15
2 PREPARATION FOR MEASUREMENT
2
PREPARATION FOR MEASUREMENT
2.1
Power Connection
(unnecessary if on-board Ni-MH battery BT-56Q is used)
See below for connecting the external battery pack.
● Battery pack BT-3Q
Power cord , PC-5 is used.
● Large capacity battery pack BT-3L
Power cord PC-6 is used.
● When using a external battery, the rechargeable battery BT-56Q should be attached
(The instrument will lack in balance if the internal battery BT-56Q is removed.)
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
The external battery and the internal battery can be used at the same time. The GPT-8000A/
8000 series will select a battery due to the battery remaining automatically.
PC-5
BT-3Q
Connector ends
PC-5
PC-6
BT-3L
2-1
PC-6
2 PREPARATION FOR MEASUREMENT
2.2 Setting Instrument Up For Measurement
Mount the instrument to the tripod. Level and center the instrument precisely to insure the best
performance. Use tripods with a tripod screw of 5/8 in. diameter and 11 threads per inch, such as the
Type E TOPCON wide- frame wooden tripod.
Reference: Leveling and Centering the Instrument
Leveling
screw A
2
2
Rotate the instrument 90° (100g) around its
vertical axis and turn the remaining leveling
screw or C to center the bubble once more.
Leveling screw C
e
90
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
1. Setting up the Tripod
First, extend the extension legs to suitable lengths
and tighten the screws on their midsections.
2. Attaching the Instrument on the Tripod
Head
Place the instrument carefully on the tripod head
and slide the instrument by loosening the tripod
screw. If the plumb bob is positioned right over the
center of the point, slightly tighten the tripod
screw.
3. Roughly Leveling the Instrument by Using
the Circular Level
1 Turn the leveling screws A and B to move the
bubble in the circular level. The bubble is now
located on a line perpendicular to a line
running through the centers of the two leveling
screws being adjusted.
Leveling screw C
3
Repeat the procedures 1 and 2 for each 90°
(100g) rotation of the instrument and check
whether the bubble is correctly centered for all
four points.
5. Centering by Using the Optical Plummet
Telescope
Adjust the eyepiece of the optical plummet
telescope to your eyesight.
Slide the instrument by loosening the tripod
screw, place the point on the center mark, and
then tighten the tripod screw. Sliding the
instrument carefully not to rotate that allows you
to get the least dislocation of the bubble.
Leveling screw B
Point
Turn the leveling screw C to bring the bubble
to the center of the circular level.
4. Centering by Using the Plate Level
1 Rotate the instrument horizontally by using
the Horizontal motion/clamp screw and place
the plate level parallel with the line connecting
leveling screws A and B, and then bring the
bubble to the center of the plate level by
turning leveling screws A and B.
Center mark
6. Completely Leveling the Instrument
Leveling the instrument precisely in a similar way
to 4. Rotate the instrument and check to see that
the bubble is in the center of the plate level
regardless of telescope direction, then tighten the
tripod screw hard.
Leveling
screw A
Leveling
screw B
2-2
2 PREPARATION FOR MEASUREMENT
Power Switch Key ON
1) Confirm the instrument is leveled.
Power ON
2) Turn the power switch ON.
Input a password
[
3) Type your password.
Self checking mode will display.
]
To skip the self checking, press [F1](ESC)
key.
Self check mode
ESC
e
Level the instrument by turning the leveling
screws.
When the leveling is within ±30" and stable,
the self checking will start.
X:00°00'00"
Y:00°00'00"
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
2.3
Self checking ...
[
1/6
]
The instrument will turn automatically and
the tilt sensor offset value will be measured
and memorized.
Self checking ...
[
6/6
]
After checking, the main menu icons will be
shown.
2002-07-07 14:30
Battery Power Remaining Display
Prog Std Mem Com
Adj Para
Main menu icons
● Self checking option
The self checking function is to check internal communication and tilt sensor offset value.
When ambient temperature is changed or the instrument is not balanced by its internal battery is
attached or detached, the self checking is recommended.
● Password option
Setting a password (Maximum 10 digits number) and activating ON of password option can be helpful
to avoid miss operation by unauthorized operator.
Setting password option is necessary to use this function.
To set password option, see Chapter 8 “PARAMETERS SETTING MODE” .
● Confirm the battery power remaining on the display. Replace with charged battery or charge when
battery level is low. Refer to Section 2.4 “Battery Level Indicator” .
2-3
2 PREPARATION FOR MEASUREMENT
2.4 Battery Level Indicator
The battery power indicator shows the level of battery strength.
Indicates Battery Power Remaining
2002-07-10 15:30:40
Measurement is possible.
Prog Std Mem Com
Adj Para
Blinking
The power is poor. The battery should be
recharged or replace the battery.
(Angle measurent can only be possible,
the auto-collimating and distance
maesurenat can not be possible.)
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
Measurement is impossible. Need to
recharge or replace the battery.
* Battery power remaining display is omitted in this manual.
Note:
1) The battery operating time will vary depending on the environmental conditions, such as
ambient temperature, charging time, and the number of times charging and discharging the
battery.
2) In low temperature (especially while the heater of display is working), the battery operating
time will shorten to one-half of normal temperature use.
3) The indicator for battery power remaining shows the power level during each measurement
mode. The condition indicated for the battery power remaining in the angle measurement
mode may not be adequate to measure a distance. Changing from angle mode to distance
mode during a poor battery condition may cause the EDM not to measure a distance.
We recommend that you check the battery condition before going into the field.
4) Also note, when changing from one measurement mode to another, the battery indicator may
not show a decrease or an increase immediately. The battery indicator system was designed
to show the general condition for the battery strength. It does not respond instantly.
5) For more information on battery usage, refer to Chapter 13 “POWER SOURCE AND
CHARGING” .
2-4
2 PREPARATION FOR MEASUREMENT
Main Menu Icons
The main menu icons are as follows.
Select the menu by pressing soft keys ([F1]~[F6]).
2002-07-10 15:30:40
Std
Mem
Com
Adj
Para
PARAMETERS SETTING MODES
The PARAMETERS SETTING MODES are
stored in memory once the instrument is OFF.
(See Chapter 8 “PARAMETERS SETTING
MODE”.)
ADJUSTMENT MODES
Used for checking and adjustment.
● Systematic errors adjustment for compensation.
● Show compensation values of systematic errors of
instrument
● Set Date & Time
● Set instrument constant value
● Optic Axis for Auto-tracking (GPT-8000A series)
(See Chapter 9 “CHECK AND ADJUSTMENT”.)
e
Prog
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
2.5
COMMUNICATION MODES
● Set communication with external instrument
● Input/Output a data file
(See Chapter 7 “COMMUNICATION MODES”.)
MEMORY MANAGE MODES
● Display memory status
● Protect/Eras/Rename/Copy Files,
● Initialize a card or internal memory.
(See Chapter 6 “MEMORY MANAGE MODES” .)
STANDARD MEASUREMENT MODES
● Angle measurement
● Distance measurement
● Coordinate measurement
(See Chapter 4 “STANDARD MEASUREMENT MODE” .)
PROGRAM MODES ( APPLICATION MEASUREMENT)
● Set a direction angle for horizontal orientation
● Retain Coordinate (STORE-NEZ)
● Remote elevation measurement
● Missing line measurement
● Line measurement
● External link for GPT-8000A series
● Off set measurement
(See Chapter 5 “PROGRAM MODES” .)
2-5
2 PREPARATION FOR MEASUREMENT
2.6 Vertical and Horizontal Angle Tilt Correction
When the tilt sensors are activated, automatic correction of vertical and horizontal angle for
mislevelment is displayed.
To ensure a precise angle measurement, tilt sensors must be turned on. The display can also be used
to fine level the instrument. If the (TILT OVER) display appears the instrument is out of automatic
compensation range and must be leveled manually.
Zenith
Zenith
Standing axis
Inclination of the standing
axis in the Y direction
Standing axis
Inclination of the standing
axis in the X direction
Trunnion axis
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
Horizontal
X
V
W
S
T
U
P
Q
R
O
D
|
● GPT-8000A/8000 series compensates both the vertical angle and the horizontal angle readings due
to inclination of the standing axis in the X and Y directions.
● For more information about dual axis compensation, see Chapter “APPENDIX” “Dual Axis
Compensation”.
When the instrument tilted over correction
range.
X:
Y:
Rotate the leveling screws and level the
instrument.
After leveling (when each axis is within ±1'30"),
the display returns to the previous mode
automatically.
X:00°00'00"
Y:00°00'00"
X,Y tilt correction range : within ±4'
● The display of Vertical or Horizontal angle is unstable when instrument is on an unstable stage or a
windy day. You can turn off the auto tilt correction function of V/H angle in this case. To set TILT
correction mode ON/OFF, refer to next page or Chapter 8 “PARAMETERS SETTING MODE”.
2-6
2 PREPARATION FOR MEASUREMENT
● Setting Tilt Correction by Soft Key
Enable you to select tilt ON/OFF function on page 2.
The setting performed here will be memorized after powering OFF.
[Example] Setting X,Y Tilt ON
Operating procedure
Option
1 Press [F6] key to get the function page 2.
Display
V : 87°55'45"
HR: 180°44'12"
[F6]
2 Press [F5](TILT) key.
[F5]
Current setting is displayed. *1
SD HD
NEZ 0SET
REC HSET R/L V/%
TILT ON (V)
[F2]
OFF
ESC
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
The display shows tilt correction value.
ON-2
e
ON-1
3 Press [F2](ON-2) key.
HOLD P1↓
TILT P2 ↓
X:00°00'00"
Y:00°00'00"
4 Press [F1] key.
[F1]
The display returns previous mode.
*1) Pressing [F6](ESC) key, the display returns previous mode.
● The tilt sensor setting will be stored in memory when the instrument is turned OFF.
The tilt sensor option can also be changed in the Parameter Setting Modes. When you change the tilt
sensor option in the angle measurement mode, it will change in the Parameter Setting Modes and visa
verse.
2.7
Compensation of Systematic Error of Instrument
1) Error of vertical axis (X,Y tilt sensor offset)
2) Collimation error
3) Error of vertical angle 0 datum
4) Error of horizontal axis
The above mentioned errors can be compensated by software, which calculated internally
according to each compensation value.
Also these errors can be compensated by software collimating one side of the telescope that is
carried out to delete the error by turning in normal and reverse both sides of telescope so far.
● To adjust or reset the above compensation value, see Chapter 9 “CHECK AND ADJUSTMENT” .
● Enable you to stop this function, see Chapter 8 “PARAMETERS SETTING MODE” or Chapter 9
“CHECK AND ADJUSTMENT” .
2-7
2 PREPARATION FOR MEASUREMENT
2.8 Resume Mode ON/OFF
The Resume mode will memorize the last display or mode when the power is turned OFF.
When the power is turned back ON, the last display or mode will be shown.
The Resume mode option only appears when the power is OFF.
Power switch key OFF
Power off
Resume mode
OFF
ON
[F1]
[F2]
ESC
Pressing [F1](OFF) key or [F2](ON) key, select the resume mode.
e
2.9 How to Enter Numerals and Alphabet Letters
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
Alpha and numeric character key entry is simple and quick from the key board.
[Example] Renaming a file in the Memory Manager Modes.
Operating procedure
Option
Display
Rename
Old name [TOPCON .DAT]
New name [
]
Alpha
1 Press [F1](Alpha) key to be entering alphabet
letter mode.
2 Enter Alphabets. *1)
Type “H”
Move cursor
Type “I”
Type “L”
Type “ ”
[9][9]
[F4]
[9][9][9]
[4][4][4]
[3][3][3]
3 Press [F1](Num) key to be entering numeric
mode.
Input “104”
←
→
[F1]
[1][0][4]
Rename
Old name [TOPCON
New name [HIL
Num
SPC
←
.DAT]
]
→
Rename
Old name [TOPCON .DAT]
New name [HIL 104 ]
Alpha
4 Press [ENT] when complete.
SPC
[F1]
SPC
←
→
[ENT]
*1) When the same alpha key is to be typed two or more times consecutively, press [F4](→) key between
characters. This moves the cursor to the right.
*2) Extensions can not be changed.
2-8
2 PREPARATION FOR MEASUREMENT
2.10 Memory Card
How to insert a memory card
1) Pull the card cover lever to open the
card cover.
2) Insert a memory card until the card
guide is up.
3) Close the card cover.
Card cover lever
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
Memory card
e
Card guide
How to extract a memory card
1) Pull the card cover lever to open the card
cover.
2) Pull down the card guide.
3) Extract the memory card.
Card guide
2-9
2 PREPARATION FOR MEASUREMENT
2.11 Inclination of Prism and Measuring Error (GPT-8000A series)
For the best results, aim or point prisms in the direction of the GPT-8000A series so that maximum
signal can be returned to the instrument. Sighting prism obliquely because of inclined settings, may
result in measuring errors. These errors will be proportional to the misalignment as showing in following
graphs. The more misalignment of the prism, the more error in measurement.
Measured data can be different according to the prism constant value. This can occur when a prism is
moving. Pin-pole prism set L1 (for one-person surveying) and pin-pole prism holder L1 (for fixed point
observation) are designed to minimize measuring error in such case. Make the best use of them. In
case you are forced to use the normal prism in inclined state because there is no other way possible,
we recommend to use switching holder, prism constant value (0 or 30mm), and set to 30mm
(Compensation value of -30mm).
Prism constant value : 0mm
Prism
Measuring
point
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
Inclined angle
Prism constant value : 30mm
Inclined angle
2-10
Instrument
point
2 PREPARATION FOR MEASUREMENT
● Prism type-2 (Normal prism)
Distance Measuring error
Angle measuring error
6
22
5
18
4
C=0
14
Increasing
distance 3
range
Angle error
range
C=0
( mm ) 2
( mm )
6
C=30
C=30
1
C=40
-1
C=40
2
0
0
0
10
-2
30
20
0
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
Inclined angle (degree)
10
30
20
Inclined angle (degree)
● Prism type - 3 or 5 (Prism unit A2/A3)
Distance Measuring error
Angle measuring error
12
4
3
8
Angle error
range
2
Increasing
distance
range
C=0
4
C=0
C=20
( mm
1
( mm)
C=20
0
0
C=30
-1
0
10
20
Inclined angle (degree)
30
-4
0
C=30
10
20
Inclined angle (degree)
30
(Example)
In case Prism constant value (C) = 0mm, Prism inclination = 20°, Measuring distance = 100m by Prism
type-2 :
● Distance error is :
From the graph prism type-2, the distance error shows in increasing range quantity 2.5mm along
curved line of C=0 when prism inclination is 20°.
● Angle error is :
From the graph prism type-2, along curved line of C=0 with prism inclination of 20°, find angle error
quantity (14.2mm) and calculate angle error by the following formula.
Angle error
-1
Angleerror range 
tan  ---------------------------------------------------- Measuring dis tan ce-
-1
14.2
= tan  --------------------

3
100x10
=29″
2-11
=
3 AUTOMATIC TRACKING / AUTOMATIC COLLIMATION (GPT-8000A series)
3
AUTOMATIC TRACKING / AUTOMATIC COLLIMATION
(GPT-8000A series)
WARNING
● Cause eye injury or blindness.
Do not stare into beam.
CAUTION
e
● Let the laser beam reach the aimed object or the target without anybody else in the laser beam path. In
case you operate laser beam open, avoid radiating laser beam to the height of man's head. It is quite
possible for the beam to enter into one's eyes, and it is possible to lose visual sight temporarily, and lose
one's caution and awareness of other dangers - avoid glaring beam.(GPT-8000A series)
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
3.1 Automatic Tracking
Measuring the moving target in automatic tracking mode.
● It is possible to perform auto-tracking only in prism mode.
When switched to the automatic tracking mode, it becomes prism mode from NP mode
automatically. Moreover, after the end of an automatic tracking does not return to Non-prism mode.
● The Coarse (10mm) mode is used for the moving target.
● Use a keyboard on the eyepiece side. When the keyboard on the opposition side is used an error
will be displayed to protect a worker from the radiation of the laser.
Operating procedure
Option
1 Manually collimate the target prism using V/H
jog/shuttle.
V : 87°55'45"
HR: 180°44'12"
SD
2 Press the star [
options.
] key to show the star key
Display
[
3 Press the [F1] key. The mode will be
]
[F1]
automatic tracking mode.
The instrument searches the prism and tracks
automatically.
NEZ
0SET
2002-07-07
HOLD P1↓
14:30:40
NP/P 1↓
V : 87°55'45"
HR: 180°44'12"
SD
3-1
HD
HD
NEZ
0SET
HOLD P1↓
3 AUTOMATIC TRACKING / AUTOMATIC COLLIMATION (GPT-8000A series)
4 Choose measuring modes by pressing the
[F2]
soft keys.
Measuring starts.
Sample: Horizontal distance measuring
V : 90°10'20"
HR: 120°30'40" PSM
0.0
HD:
< PPM
0.0
VD:
(m) *c.R
MEAS MODE VH SD NEZ P1↓
● If the target prism is lost during auto tracking status, the instrument will automatically change to Waiting
status and symbol mark will be switched. If the target is found during Waiting status, tracking resumes,
and if not, status changes to Searching status. When the target prism is found, tracking will resume.
Automatic tracking
Star key
mode
Normal
mode
F1
Tracking
status
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
The target prism is lost
Waiting status
The target prism
is found
The target prism is not found
for some time
Searching status
● The following symbol marks are indicated at the right side of the display.
In all these status, laser beam is emitting.
Tracking status
Waiting status
Searching status
● Auto tracking status sometimes can be unstable for a few seconds after the optical path is disturbed.
● If the center of reticle and the center of the prism is not coincided, you should adjust optical axis for
auto-tracking, refer to chapter 9"Check and adjustment".
● In the not suitable operating condition in such the atmospheric condition is not good by the heat
shimmer, or other bad weather condition, in the long distance of the auto-tracking limit, can be
happened not certain tracking or not tracking at the center of the prism.
3-2
3 AUTOMATIC TRACKING / AUTOMATIC COLLIMATION (GPT-8000A series)
3.2 Automatic Collimation
The function enables to collimate automatically so that the instrument searches for the center of the
prism when the telescopic is aimed a prism roughly.
Use this mode for the object which is stable.
● You can select Fine or Course mode for the distance measurement in auto-collimation.
Operating procedure
Option
1 Manually collimate the target prism roughly
Display
V : 87°55'45"
HR: 180°44'12"
using V/H jog/shuttle.
SD
2 Press the star [
] key.
[
HD
NEZ
0SET
2002-07-07
]
HOLD P1↓
14:30:40
NP/P 1↓
3 Press the [F2] key.
[F2]
V : 87°55'45"
HR: 180°44'12"
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
The instrument begins to collimate When it
searches the prism.
SD
4 Choose measuring modes by pressing the
[F2]
soft keys.
Measuring starts.
Sample: Horizontal distance measuring
HD
NEZ
0SET
HOLD P1↓
V : 90°10'20"
HR: 120°30'40" PSM
0.0
HD:
< PPM
0.0
VD:
(m) *c.R
MEAS MODE VH SD NEZ P1↓
● In case the instrument could not find the prism during auto-collimating, the auto-collimating mode
returns to normal mode after displaying the mark as follows.
Instrument could not find the prism
● If any key is pressed during auto-collimating, the auto-collimating mode returns to normal mode.
● After auto-collimating is finished, the instrument does not track the prism even if the prism is moved.
● The auto-tracking can be done correctly in the time of shaking prism, or in bad weather condition is not
good by the heat shimmer. The above caution mark will be displayed after 10 seconds and the autotracking will be finished.
3-3
3 AUTOMATIC TRACKING / AUTOMATIC COLLIMATION (GPT-8000A series)
Range of Laser for Auto-tracking and Auto-collimating
The range of laser at the long distance is within ±30' as shown in following. So you had better collimate
the prism so that the prism may be located within this range of laser in the first step. As for it, rapid
automatic collimating and automatic tracking becomes possible. If the target prism is out of this range,
time for searching mode will be necessary.
Field of view
about ±30'
Range of laser
e
about ±30'
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
3.3
3-4
3 AUTOMATIC TRACKING / AUTOMATIC COLLIMATION (GPT-8000A series)
3.4 Setting Parameters for Auto-Tracking
A proper setting for each parameter are necessary for custom use.
The setting of the parameters can be done in the star key mode.
3.4.1 Setting Items
Items
Selecting item
Contents
PATTERN 1
SEARCH
RANGE
V:0° to 90°
H:0° to180°
The search range is the area to searched for the prism by rotating
the telescope and body in searching. The SEARCH range is
decided from the point where the prism lost, and the values will be
set to plus and minus directions in horizontal and vertical. Also it is
enable to set each search pattern separately.
WAIT TIME
0:00 to1:00:00
(1sec. step)
The time the prism is lost before GPT-8000A series starts the
searching. If the mode is set to [HOLD], mode will not change to
searching.
PATTERN 2
HOLD
REFRECTOR
TYPE
SURVEY
Select your purpose.
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
TRACKING
SPEED
The search range is the area to searched for the prism by rotating
the telescope and body in searching.
e
SEARCH
PATTERN
MACHINE
CONTROL
PRISM
The type of the refrector can be selected.
REFRECTOR
TAPE
1) Search Patterns
The search pattern is the rotating method of telescope and instrument to find the target prism in search
mode. Search pattern includes the following 2 ways that can be selected.
PATTERN 1
PATTERN 2
This pattern can be selected to search the prism at the point where the prism is lost.
Instrument searches in up down direction gradually from the point where the prism is lost.
The searching is arranged to 2 times until the prism is found.
The auto tracking mode changes to manual mode when the refrector could not found out
within 2 times searching, and returns to the point where the refrector is lost.
This pattern can be selected to search for the prism. The search pattern tries to locate the
prism in a very short time.
The searching is arranged to 2 times until the refrector is found.
The auto tracking mode changes to manual mode when the refrector could not found out
within 2 times searching, and returns to the point where the refrector is lost.
1) Things like heat haze might interfere with the tracking system in the long distance, near limit of auto
tracking range, in search mode.
2) Reaction by rotating of instrument in search mode is serious. Be sure of each connection part of the
tribrach or tripod are firmly.
3-5
3 AUTOMATIC TRACKING / AUTOMATIC COLLIMATION (GPT-8000A series)
2) Search Range
The search range is the area to searched for the prism by rotating the telescope and body in Searching.
The Search range is decided from the point where the prism lost, and the values will be set to plus and
minus directions in horizontal and vertical.
Select search pattern first, and set the search range to the selected search pattern. Also it is enable to
set each search pattern separately.
[Example] SEARCH RANGE : 10° in horizontal, 5° in vertical
Search range
+5°
10°
-5°
Point where prism lost
-10°
+10°
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
20°
Setting Search range requires consideration. The items to think about: optical path interrupted by other
objects; collimated point from GPT-8000A series to prism is shifted after Turning and Searching
Command; possible other prisms, targets, or other objects to interfere with tracking the desired prism;
and many other examples all play a role in determining the search range.
Note: This search range is only for auto-tracking function. The search range of auto-collimating is fixed
as ±5° in both directions horizontal and vertical.
3) Wait Time
The time the prism is lost before GPT-8000A series starts the searching. Setting time is 1second step
maximum 60 minutes.
If the mode is set to [HOLD], mode will not change to searching.
4) Tracking Speed
The tracking accuracy (aiming accuracy) shall be determined in the best condition by the relationship of
moving speed of the prism and the distance between GPT-8000A series and the prism at the field.
Since the tracking speed represents the rotating speed of GPT-8000A series, if the prism’s traveling
speed is high, yet the distance of the prism is far from the GPT-8000A series, the tracking speed can be
low.
SURVEY
MACHINE
CONTROL
● In case requiring auto aiming in high accuracy to the prism which is still.
● Suitable for fixed point observation, management of landslides, surveying
displacement of dam.
● When beginning auto-tracking, the instrument needs to collimate stable prism.
● Suitable for controlling of construction machinery or real time surveying of variety
traveling objects.
● When beginning auto-tracking, the instrument can track a prism, even if the prism is
moving.
5) Reflector type
You can choose a reflector type according to reflective objects such as Prism-2 or reflector tape.
This setting will reduce incorrect tracking.
3-6
3 AUTOMATIC TRACKING / AUTOMATIC COLLIMATION (GPT-8000A series)
3.4.2 How to set the parameters
Sample setting: Set TRACKING SPEED to [MACHINE CONTROL]
Operating procedure
1 Press the star [
] key to be in star key
Option
[
Display
2002-07-07
]
14:30:40
mode.
NP/P
2 Press the [F3] key to select the setting
[F3]
parameters for auto-tracking.
1↓
F1:SEARCH PATTERN
F2:SEARCH RANGE
F3:WAIT TIME
P1↓
3 Press the [F6](P1↓) key to get the menu on
[F6]
page 2.
F1:TRK SPEED
F2:REFLECTOR TYPE
4 Press the [F1](TRK SPEED) key.
TRACKING SPEED
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
5 Press the [F6](↓) key to select [MACHINE
CONTROL].
[F1]
e
P1↓
[F6]
SURVEY
↑
↓
↑
↓
TRACKING SPEED
MACHINE CONTROL
6 Press the [ENT] key to decide.
[ENT]
3-7
4 STANDARD MEASUREMENT MODE
4
STANDARD MEASUREMENT MODE
2002-07-10 15:30:40
[Press [F2] key.]
STANDARD MEASUREMENT MODE
Angle measurement, Distance measurement,
Coordinate measurement .
Prog Std Mem Com Adj Para
4.1
Angle Measurement
4.1.1 Measuring Horizontal Angle Right and Vertical Angle
Make sure the mode is in Angle measurement.
Operating procedure
1 Collimate the 1st target (A).
Operation
Collimate
A
Display
V : 87°55'45"
HR: 180°44'12"
HD
NEZ
0SET
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
SD
2 Set horizontal angle of target A at 0° 00' 00".
[F4]
Press [F4](0 set) key and [F6](SET) key.
H-0SET
HR: 00°00'00"
ESC
[F6]
V :
HR:
SD
3 Collimate the 2nd target (B).
The required H/V angle to target B will be
displayed.
Collimate
B
HOLD P1↓
SET
87°55'45"
00°00'00"
HD
NEZ
0SET
HOLD P1↓
0SET
HOLD P1↓
V : 87°55'45"
HR: 123°45'50"
SD
HD
NEZ
Reference : How to Collimate
1
2
3
Point the telescope toward the light. Turn the diopter ring and adjust the diopter so that the cross
hairs are clearly observed.
(Turn the diopter ring toward you first and then backward to focus.)
Aim the target at the peak of the triangle mark of the sighting collimator. Allow a certain space
between the sighting collimator and yourself for collimating.
Focus the target with the focusing knob.
*If parallax is created between the cross
hairs and the target when viewing
vertically or horizontally while looking
into the telescope, focusing is incorrect
or diopter adjustment is poor.
This adversely affects precision in
measurement or survey. Eliminate the
parallax by carefully focusing and using
diopter adjustment.
Focusing knob
Telescope eyepiece (Diopter ring)
Åá
Åá
4-1
Åá
Åá
4 STANDARD MEASUREMENT MODE
4.1.2 Switching Horizontal Angle Right/Left
Make sure the mode is Angle measurement.
Operating procedure
Operation
Display
1 Press [F6](↓)key to get the function as on
V : 87°55'45"
HR: 120°30'40"
page 2.
SD
HD
NEZ 0SET
TURN HSET R/L V/%
[F6]
2 Press [F3](R/L) key.
V : 87°55'45"
HL: 239°29'15"
[F3]
The mode Horizontal angle Right (HR)
switches to (HL) mode.
TURN HSET
R/L
HOLD P1↓
TILT P2↓
PSM
0.0
PPM
0.0
(m) *F.R
V/% TILT P2↓
3 Measure as HR mode.
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
● Every time pressing [F2](R/L) key is pressed, HR/HL mode switches.
● HR/HL switching can be turned OFF. Refer to Chapter 8 “PARAMETERS SETTING MODE” .
4.1.3 Measuring from the Required Horizontal Angle
1) Setting by Holding the Angle
Make sure the mode is angle measurement.
Operating procedure
1 Set the required horizontal angle, using
Horizontal jog/shuttle.
Operation
Display
angle
V :
HR:
SD
2 Press [F5](HOLD) key.
[F5]
Display
90°10'20"
70°20'30"
HD
NEZ
0SET
Holding
HR: 70°20'30"
ESC
3 Collimate the target.*1)
HOLD P1↓
REL
Collimate
4 Press [F6](REL) key to finish holding the
[F6]
horizontal angle.
The display turns back to normal angle
measurement mode.
V :
HR:
SD
*1)To return to the previous mode, press [F1](ESC) key.
4-2
HD
90°10'20"
70°20'30"
NEZ
0SET
HOLD P1↓
4 STANDARD MEASUREMENT MODE
2) Setting a Horizontal Angle from the Keys
Make sure the mode is Angle measurement.
Operating procedure
1 Collimate the target.
Operation
Display
Collimate
2 Press [F6](↓) key to get the function as on
[F6]
page 2, and press [F2](HSET) key.
V : 90°10'20"
HR: 120°30'40"
SD HD NEZ 0SET HOLD P1 ↓
TURN HSET R/L V/% TILT P2 ↓
[F2]
Input
value
3 Input the required horizontal angle.
*1)
For example:70 °20'30"
H-SET
HR:
H-SET
HR:70.203
EXIT
[ENT]
V :
HR:
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
When completed, normal measuring from the
required Horizontal angle is possible.
90°10'20"
70°20'30"
e
4 Press [ENT] key. *2)
BS
SD
HD
NEZ
0SET
HOLD P1↓
*1)To revise wrong value, move cursor with [F6](BS) key, or input from the beginning by [F1](EXIT) key to
correct value.
*2)With wrong input value (for example 70'), setting will not be completed. Input again from step 3.
4.1.4 Vertical Angle Percent Grade(%) Mode
Make sure the mode is Angle measurement.
Operating procedure
Operation
1 Press [F6](↓) key to get the function as on
page 2.
Display
V : 90°10'20"
HR: 120°30'40"
[F6]
2 Press [F4](V/%) key. *1)
[F4]
SD HD NEZ 0SET HOLD P1↓
TURN HSET R/L V/% TILT P2↓
V%:
-0.30
%
HR: 120°30'40"
TURN HSET
*1) Every time pressing the [F4](V/%) key, the display mode switches.
4-3
R/L
V/% TILT P2 ↓
4 STANDARD MEASUREMENT MODE
4.1.5 Automatic Rotation to a Required Horizontal and Vertical Absolute Angle
The GPT-8000A/8000 series can be rotated to a required horizontal and vertical absolute angle by
direct key input.
Example: Both vertical and horizontal angle
Operating procedure
Operation
1 Press the [F6](↓) key to display the second
Display
V : 87°55'45"
HR: 120°30'40"
soft key page.
[F6]
SD HD NEZ 0SET HOLD P1↓
TURN HSET R/L V/% TILT P2↓
[F1]
TURN(Absolute)
F1. V angle
F2. H angle
F3. V/H angle
3 Press the [F3] key.
[F3]
TURN(Absolute)
V :
HR:
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
2 Press the [F1](TURN) key.
EXIT
4 Input the vertical angle to be rotated and
press [ENT] key. *1)
For example : 93°10'40"
BS
V angle
[ENT]
H angle
[ENT]
5 Input the horizontal angle to be rotated, and
TURN(Absolute)
V : 93°10'10"
HR: 160°20'10"
press [ENT] key.
For example : 160°20'10"
The instrument will start to rotate. *2)
When the instrument has finished rotating *3),
the instrument will return to the previous
mode.
<Rotating...>
*1) Setting range for rotation is ;
0°00' 00"≤ HR ≤+359°59' 59"
0°00' 00"≤ V ≤ +359°59' 59"
*2) Press any key except power key to stop rotating in emergency during operation.
*3) You can select a accuracy of the actual stopping angular positions. Refer to Chapter 8 “PARAMETERS
SETTING MODE” .
4-4
4 STANDARD MEASUREMENT MODE
4.2
Distance Measurement
Note: Those distance shorter than 2.5m will not be displayed in Non-prism mode.
● Prism mode and Non-prism mode
In GPT-8000A/8000 series, the distance measurement will be done using invisible pulse laser beam
emitted from pulse laser diode. You can select measurement mode between Prism mode which
collimating a prism and Non-prism mode that is collimating a target object except prism.
Non-prism mode enables all distance measurements such Distance measurement, Coordinate
measurement and Offset measurement.
To switch over Prism mode to Non-prism mode or contrary, press the [F5] key in star key (
)
mode. [NP] of Non-prism mode indicator will blink at the right corner of the display in Non-prism
mode measurement and Non-prism constant value (NPM) will be displayed.
Changing mode shall be done before measurement.
If happened collimating the near distance prism in Non-prism mode, measurement will not be done
because of too much light.
Distance measurement mode
Example
e
Non-prism mode indicator
Non-prism constant value
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
V : 90 10'20"5
NP
HR: 120 30'40"5 NPM
0.0
HD:
PPM
0.0
VD:
(m) F.R
MEAS MODE VH SD NEZ P1↓
4.2.1 Setting of the Atmospheric Correction
When setting the atmospheric correction, obtain the correction value by measuring the temperature and
pressure.
Setting the atmospheric correction is in the STAR key
() mode, see Chapter SETTING
11 “
ATMOSPHERIC CORRECTION” .
4.2.2 Setting of the Correction for Prism Constant / Non-prism Constant
Topcon's prism constant value is 0. Set correction for prism at 0. If the prism is of another manufacture,
the appropriate constant shall be set beforehand.
Setting the prism constant value is in the STAR key (
) mode, see Chapter 10 “SETTING THE
PRISM / NON-PRISM CONSTANT VALUE” .
Note: Confirm that Non-prism correction value is set at zero before measurement target such
as a wall in Non-prism mode.
4-5
4 STANDARD MEASUREMENT MODE
4.2.3 Distance Measurement (Continuous Measurement)
Make sure the mode displays angle measurement.
Operating procedure
Operation
1 Collimate the center of prism.
Display
V : 90°10'20"
HR: 120°30'40"
SD
2 Press [F1](SD) key or [F2]( HD )key.
[F2]
*1), 2)
[Example] Horizontal distance mode
HD
NEZ
0SET
V : 90°10'20"
HR: 120°30'40"
HD:
<
VD:
MEAS MODE VH
HOLD
P1↓
PSM
0.0
PPM
0.0
(m) *F.R
SD NEZ P1 ↓
V : 90°10'20"
HR: 120°30'40"
PSM
0.0
HD:
716.661 PPM
0.0
VD:
4.001
(m) *F.R
MEAS MODE VH
SD NEZ P1 ↓
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
The result are shown *3) to *6)
*1) The following characters will be shown on the 4th line right hand corner of the display to
represent measurement mode.
F: Fine meas. mode, C: Coarse (1mm) meas. mode, c: Coarse (10mm) meas. mode.
R: Continuous (Repeat) meas. mode , S: Single meas. mode, N: N time meas. mode
*2)
*3)
*4)
*5)
*6)
When EDM is working, the "* " mark appears in the display.
The result is shown with buzzer sound.
Measurement may repeat automatically if the result is affected by shimmer etc..
To change single measuring, press [F1](MEAS) key.
To return to the angle measurement mode, press [F3](VH) key.
4-6
4 STANDARD MEASUREMENT MODE
4.2.4 Distance Measurement (Single/N-times Measurement)
When presetting the number of times, the instrument measures the distance as the setting times and
the average distance will be displayed.
When presetting the number of times as 1, it does not display the average distance, because of single
measurement. It has been set at single measurement at factory.
1)Setting the number of times
Confirm the angle measurement mode.
Operating procedure
Operation
1 Press [F1](SD) or [F2](HD) key.
Display
V : 90°10'20"
HR: 120°30'40"
SD
NEZ
0SET
HOLD P1↓
V : 90°10'20"
HR: 120°30'40"
PSM
0.0
HD:
PPM
0.0
VD:
(m) F.R
MEAS MODE VH SD NEZ P1↓
REC
SO MEAN
m/ft
P2↓
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
[F2]
HD
[F6]
2 Press [F6](↓) key to get the function page as
2.
3 Press [F3](MEAN) key.
[F3]
Average times
N:0
4 Input the setting the number of times, and
press [ENT] key. *1)
[Example] 4 times
N-times measurement starts.
[F4][ENT]
EXIT
BS
V : 90°10'20"
HR: 120°30'40"
PSM
HD:
<
PPM
VD:
(m)
REC SO
MEAN
m/ft
0.0
0.0
*F.N
P2↓
2)Measuring Method
Confirm the angle measurement mode.
Operating procedure
1 Collimate the center of the prism.
Operation
Collimate
V : 90°10'20"
HR: 120°30'40"
SD
2 Select the measurement mode by pressing
[F2]
[F1](SD) or [F2](HD) key.
Example: Horizontal distance
N-times measurement starts.
4-7
Display
HD
NEZ
0SET
HOLD P1↓
V : 90°10'20"
HR: 120°30'40"
PSM
0.0
HD:
PPM
0.0
VD:
(m) F.N
MEAS MODE VH SD NEZ P1↓
4 STANDARD MEASUREMENT MODE
V : 90°10'20"
HR: 120°30'40"
PSM
0.0
HD:
54.321
PPM
0.0
VD:
1.234
(m) *F.N
MEAS MODE VH
SD
NEZ P1 ↓
The average value is displayed following with
buzzer sound and “ * ” mark disappears.
V :
90°10'20"
HR: 120°30'40"
PSM
0.0
HD:
54.321
PPM
0.0
VD:
1.234
(m) F.N
MEAS MODE VH
SD NEZ P1↓
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
● Press [F1](MEAS) key for re-measuring after the measurement in held.
● To return to the continuous measuring , press [F1](MEAS) key twice.
● To return to the angle measuring mode , press [F3](VH) key.
4-8
4 STANDARD MEASUREMENT MODE
4.2.5 Fine / Coarse Measuring Mode
•Fine mode
: This is a normal distance measuring mode.
Measurement time
0.2mm mode : approx.3 seconds
1 mm mode : approx.1.2 seconds
The unit to be displayed is 0.2mm or 1mm. (0.001ft or 0.005ft)
•Coarse mode
(1mm)
: This mode measures in shorter time than in fine mode.
Use this mode for the objects which may be slightly unstable.
Measurement time : approx. 0.5 seconds
The unit to be displayed is 1mm. (0.005ft)
•Coarse mode
(10mm)
: This mode measures in shorter time than in coarse(1mm) mode.
Use this mode for stake out measurement. It is very useful when tailing the
moving object or carrying out stake-out work.
Measurement time : approx. 0.3 seconds
The unit to be displayed is 10mm. (0.02ft)
Operation
V: 90°10'20"
HR: 120°30'40"
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
Collimate
Display
e
Operating procedure
1 Collimate the center of prism.
SD
2 Select the measurement mode by pressing
[F1](SD) or [F2](HD) key.
Example: Horizontal distance
Measuring starts.
3 Press [F2](MODE) key, the mode changes to
Coarse mode.
Press [F2](MODE) key again, the mode
changes to Tracking mode. *1)
HD
NEZ
0SET
[F2]
V : 90°10'20"
HR: 120°30'40"
PSM 0.0
HD:
<
PPM 0.0
VD:
(m) *F.R
MEAS MODE VH
SD NEZ P1↓
[F2]
[F2]
V : 90°10'20"
HR: 120°30'40"
HD:
VD:
MEAS MODE VH
*1) Every time the [F2](MODE) key is pressed, the mode will change as demonstrated.
The mode is indicated in the alphabet (F, C, c) on the bottom right of the screen.
F: Fine mode, C: Coarse 1mm mode, c: Coarse 10mm mode
4-9
HOLD P1 ↓
PSM
PPM
(m)
SD NEZ
0.0
0.0
c.R
P1 ↓
4 STANDARD MEASUREMENT MODE
4.2.6 Stake Out (S-O)
The stake out distance is the difference between the measured distance and the preset distance.
Display value = Measured distance -Standard (Preset) distance
The value on the display is the distance in which the rod person must move toward or away from the
instrument. A minus (-) sign appearing before the stake out distance indicates that the rod person
would move away from the instrument to reach the stake out distance. If the stake out distance is
displayed with no sign, indicating positive (+), the rod person toward the instrument to reach the stake
out distance.
● Stake out operation can be accomplished in any distance measuring mode, horizontal distance
(HD), relative elevation (VD), or slope distance (SD).
[Example: Relative elevation]
Operation
mode to get the function as in page 2.
[F6]
[F2]
[ENT]
V : 90°10'20"
HR: 120°30'40"
HD:
VD:
MEAS MODE VH
TURN
SO
MEAN
3 Enter the relative elevation for stake out, and
press [ENT] key.
The measuring starts.
Enter
value
[ENT]
4 Collimate the target (Prism).
The difference between the measured
distance and the standard distance is
displayed.
PSM
PPM
(m)
SD
NEZ
m/ft
0.0
0.0
F.R
P1↓
P2↓
SO
HD : 0.000
VD :
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
2 Press [F2](S-O) key and press [ENT] key.
Display
e
Operating procedure
1 Press [F6](P1) key in the distance measuring
EXIT
V :
90°10'20"
HR : 120°30'40"
HD :
<
dVD :
TURN
SO MEAN
V : 90°10'20"
HR: 120°30'40"
HD:
12.345
dVD:
0.09
TURN SO MEAN
BS
PSM
0.0
PPM
0.0
(m) *F.R
m/ft
P2↓
PSM
0.0
PPM
0.0
(m) *F.R
m/ft
P2 ↓
● To return to normal distance measurement mode, reset the standard distance to “ 0 ” or turn the power
switch off (Resume mode: OFF) once.
4-10
4 STANDARD MEASUREMENT MODE
4.3
COORDINATE MEASUREMENT
4.3.1 Setting Coordinate Values of Occupied Point
The occupied point coordinates (NEZ) can be preset in the GPT-8000A/8000 Series to calculate the
unknown point coordinates. It is possible to retain the occupied coordinates in memory once the power
is turned OFF if the (NEZ mem) is ON in the Parameter Setting Modes. IF (NEZ mem) is OFF in the
Parameter Setting Modes, the occupied coordinates will be retained only if you choose (Resume ON)
when shutting the power OFF.
For instructions on how to select NEZ memory ON/OFF, refer to Chapter 8 “PARAMETERS SETTING
MODE” .
Prism (n,e,z)
N
z
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
n
Inst.PointC
Origin(0,0,0)
e
E
Confirm the angle measurement mode.
Operating procedure
Operation
Display
V : 90°10'20"
HR: 120°30'40"
SD
1 Press [F3](NEZ) key.
[F3]
2 press [F6](↓) key to get the function as on
page 2.
3 Press [F5](SET) key.
The previous data will be shown.
[F6]
[F5]
4-11
HD
NEZ
0SET
N :
E :
Z :
<
MEAS
TURN
MODE VH
HT MEAN
HOLD P1↓
PSM
0.0
PPM
0.0
(m) *F.R
SD
HD
P1↓
m/ft SET P2↓
Setting occ. point
N :
12345.6700
E :
12.3400
Z :
10.2300
EXIT
BS
4 STANDARD MEASUREMENT MODE
4 Input new data and press [ENT] key. *1)
N coord.
[ENT]
E coord.
[ENT]
Z coord.
[ENT]
Setting occ. point
N : 0.0000
E : 0.0000
Z : 0.0000
EXIT
BS
Complete
N :
E :
Z :
Measuring starts.
HT
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
TURN
<
*1)To cancel the setting, press [F1](EXIT) key.
4-12
MEAN
PSM
PPM
(m)
m/ft SET
0.0
0.0
*F.R
P2↓
4 STANDARD MEASUREMENT MODE
4.3.2 Setting of the Instrument Height / Prism Height
The instrument height and prism height are used to compute the ground elevation of the unknown point.
If the option to store NEZ is (on), the instrument and prism heights will be stored in memory when
power is turned off.
Confirm the angle measurement mode.
Operating procedure
Operation
Display
V : 90°10'20"
HR: 120°30'40"
SD
[F3]
2 Press [F6](↓) key from the coordinate
[F6]
3 Press [F2](HT) key to type in the instrument
and prism height.
Previous data will be shown.
MEAS MODE VH
TURN HT MEAN
key.*1)
5 Input prism height, and press [ENT] key.
HOLD P1↓
PSM
0.0
PPM
0.0
(m) *F.R
SD
HD
P1↓
m/ft SET
P2↓
[F2]
Inst. Ht
R. Ht
EXIT
4 Input instrument height, and press [ENT]
0SET
N :
E :
Z :
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
measurement mode to get the function as in
page 2.
NEZ
e
1 Press [F3](NEZ) key.
HD
:
:
1.230 m
1.340 m
BS
Inst. HT
[ENT]
Prism HT
[ENT]
The display returns to coordinate measuring
mode.
N :
E :
Z :
TURN HT
*1)To cancel the setting, press [F1](EXIT) key.
4-13
MEAN
PSM
0.0
PPM
0.0
(m) *F.R
m/ft SET P2↓
4 STANDARD MEASUREMENT MODE
4.3.3 Execution of Coordinate Measuring
Measure the coordinates by entering the instrument height and prism height, coordinates of unknown
point will be measured directly.
e
● When setting coordinate values of occupied point, see Section 4.3.1“Setting Coordinate Values of
Occupied Point” .
● When setting the instrument height and prism height, see Section 4.3.2“Setting of the Instrument
Height / Prism Height” .
● The coordinates of the unknown point are calculated as shown below and displayed:
Coordinates of occupied point : (N0, E0, Z0)
Instrument height : Inst.h
Prism height
: R.h
Vertical distance (Relative elevation) : z
Coordinates of the center of the prism,
originated from the center point of the instrument : (n,e,z)
Coordinates of unknown point : (N1, E1, Z1)
N1 = N0 + n
E1 = E0 + e
Z1 = Z0 + Inst.h + z - P.h
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
Coordinates of the center of the prism, originated from the center point of the instrument (n,e,z)
Center point of the instrument
(No, Eo, Zo + Inst.h)
Unknown point
(N1, E1, Z1)
Occupied point (No, Eo, Zo)
Origin (o, o, o)
Confirm the angle measurement mode.
Operating procedure
Operation
1 Set coordinates values of occupied point and
2
instrument/prism height. *1)
Set the direction angle of known point A. *2)
3 Collimate target B.
4 Press [F3](NEZ) key.*3)
Measuring starts.
Display
V : 90°10'20"
HR: 120°30'40"
Set
direction
angle
SD
HD
NEZ
0SET
HOLD P1↓
Collimate
[F3]
MEAS
4-14
<
N :
E :
Z :
MODE
VH
PSM
0.0
PPM
0.0
(m) *F.R
SD
HD P1↓
4 STANDARD MEASUREMENT MODE
The result will be shown.
N : 12345.6789
E : -12345.6789
Z :
10.1234
MEAS
MODE
VH
SD
PSM
0.0
PPM
0.0
(m) *F.R
HD
P1↓
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
*1) In case the coordinate of instrument point is not entered, (0,0,0) will be used as the default for the
instrument point.
The instrument height will be calculated as 0 when the instrument height is not entered.
*2) The prism height will be calculated as 0 when the prism height is not set.
*3) Refer to Section 4.1.3“Measuring from the Required Horizontal Angle”or Section 4.1.3“Measuring from
the Required Horizontal Angle”
*4) Pressing [F1](MEAS) key, the measurement mode (Continuous measuring/ N-time measuring)
changes.
Pressing [F2](MODE) key, the measurement mode (FINE/ COARSE(1mm)/ COARSE(10mm)) changes.
● To return to the normal angle or distance measuring mode, press [F6](P2↓) key to return to the function
as on page 1 and press [F3](VH),[F4](SD) or [F5](HD) key.
4-15
4 STANDARD MEASUREMENT MODE
4.4 DATA OUTPUT
Result of measurement is transferred to Data Collector (FC series) from GPT-8000A/8000 series.
[Example: Distance measurement mode]
Confirm the distance measurement mode.
Operating procedure
Display
Measurement will be started.
2 The result will be shown and transferred to the Data
Collector.
measurement mode.
PSM
0.0
PPM
0.0
(m) *F.R
SD NEZ P1↓
V :
90°10'20"
HR: 120°30'40"
PSM
0.0
HD:
10.1234
PPM
0.0
VD:
1.234
(m) *F.R
REC > > >
V :
90°10'20"
HR: 120°30'40"
PSM
0.0
HD:
10.1234
PPM
0.0
VD:
1.234
(m) *F.R
MEAS MODE VH
SD NEZ P1 ↓
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
3 The mode will automatically return to the distance
V : 90°10'20"
HR: 120°30'40"
HD:
<
VD:
MEAS MODE VH
e
1 Operate the data collector to measure the distance.
The following data will be output at each mode.
Mode
Output
Angle mode (V,HR or HL) (V in percent)
V, HR (or HL)
Horizontal distance mode (V, HR, HD, VD)
V, HR, HD, VD
Slope distance mode (V, HR,SD)
V, HR, SD,HD
Coordinate mode
N, E, Z, HR
● The display and the output at the coarse (1mm) mode are the same as the contents above.
● Output at the coarse (10mm) mode is displayed as distance data only (HD, VD or SD).
4-16
4 STANDARD MEASUREMENT MODE
● Data output of GPT-8000A series
The information of GPT-8000A series regarding tracking auto-tracking are added to the protocol of
Topcon Total Station system so far.
Also you can add utility information such as battery remaining, EDM mode, auto-tracking mode, normal/
reversed face information, Tilt information if you like. For selecting, refer to Chapter 8 “PARAMETERS
SETTING MODE” .
During an utility function selection, measurement will be continued whenever tilt over. The tilt over will
not be compensated here.
In case tilt over, the tilt information will be displayed on the upper right screen as the following marks
during the utility function is selected.
Tilt information
Marks
Status of tilt
[t]
Under tilt compensation
[?]
Tilt Over
e
[t]
PSM
0.0
PPM
0.0
(m) *c.R
SD
NEZ
P1↓
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
V : 90° 10'20"
HR: 120° 30'40"
HD:
<
VD:
MEAS
MODE
VH
[ ]
*
Tilt OFF
● Control by interface for Topcon AP-L1A system, see Chapter 5 “ PROGRAM MODES” -[EXT.LINK]
section.
● When using other wireless modem or optical remote controller, select to [None] for the protocol of
communication in Chapter 8 “PARAMETERS SETTING MODE” .
4-17
5 PROGRAM MODES
5
PROGRAM MODES
2002-07-10 15:30:40
[Press [F1] key.]
Prog Std Mem Com Adj Para
Programs
F1 BS
F2 STORE
F3 REM
F4 MLM
p
p
p
p
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
PROGRAM MODE (APPLICATION MEASUREMENT)
1.Setting a Horizontal Angle
2.Retaining a Coordinate (STORE-NEZ)
3.Remote Elevation Measurement (REM)
4.Missing Line Measurement (MLM)
5.Line Measurement (LINE)
6.Offset Measurements (OFF SET)
7.External Link (only for GPT-8000A series)
4/7
[F6](MORE) key
Programs
F1 LINE
F2 OFFSET
p
p
6/6
MORE
MORE
GPT-8000 series
Programs
F1 LINE
F2 OFFSET
F3 EXT.LINK
p
p
p
7/7
MORE
GPT-8000A series
5-1
5 PROGRAM MODES
5.1
Setting a Direction Angle for Backsight Orientation
(Entering the instrument and backsight coordinate values)
From the coordinate value of backsight point (bearing point) and instrument point, the direction angle
from the instrument point to the backsight point can be set.
N
Backsight point A
Instrument point C
Direction angle
E
Operation
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
Operating procedure
e
Example: Backsight point A : N coordinate 54.321m, E coordinate 12.345m
Programs
F1 BS
F2 STORE
F3 REM
F4 MLM
1 Press [F1](BS) key.
Example : N coordinate;54.321m
: E coordinate;12.345m
p
p
p
p
4/7
MORE
[F1]
Setting Direction Angle
BS:M-POINT
N :
1234.567 m
E :
2345.678 m
INP
OK
[F6]
N data
[ENT]
E data
[ENT]
Setting Direction Angle
BS:T-POINT
N :
54.321 m
E :
12.345 m
EXIT
BS
Current data will be displayed. *1)
2 Press [F6](OK) key.
3 Input N and E coordinate of backsight point A.
Display
Setting Direction Angle
BS
HR : 320°10'20"
> Set OK?
EXIT
YES
NO
4 Sight backsight point A.
5 Press [F5](YES) key.
[F5]
Complete
The display returns to main menu.
*1)If you need to change the occupied point data, press [F1](INP) key and input new data.
5-2
5 PROGRAM MODES
5.2 Retaining a Coordinate (STORE- NEZ)
Suppose the instrument P0 moves to P1, P2, P3, etc. and the coordinate at P1, P2, P3 etc., last point
will be retained in the memory, after moving, as from the origin point.
N
P1
Known point A
P3
P2
Direction angle
Inst. point P0
Origin (0,0,0)
E
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
● Set the coordinate value of instrument point P0 and set the direction angle from instrument point P0
toward known point A .
Operating procedure
Operation
Programs
F1 BS
F2 STORE
F3 REM
F4 MLM
Display
p
p
p
p
4/7
MORE
1 Press [F2](STORE) key.
[F2]
Retaining Coordinate
1.Store NEZ
2.Recall NEZ
2 Press [F1](Store NEZ) key. *1)
[F1]
Store NEZ
HR :
120°30'40"
HD :
m
MEAS
3 Collimate target P1 prism which the
instrument moves.
Collimate
P1
4 Press [F1](MEAS) key.
[F1]
Measuring will start.
HT
Store NEZ
HR :
100°10'20"
HD *
< m
MEAS
Horizontal distance and horizontal angle are
shown.
SET
SET
Store NEZ
HR :
100°10'20"
HD *
123.456 m
MEAS
5-3
SET
5 PROGRAM MODES
5 Press [F6](SET) key.
[F6]
Coordinate of P1 will be displayed.
6 Press [F5](YES) key.
Store NEZ
N :
123.456 m
E :
12.345 m
Z :
1.234 m
> SET OK?
YES
NO
[F5]
Coordinate of P1 will be decided.
Complete
Turn power off and move instrument to P1
( Prism P1 move to P0).
7 After the instrument is set up at P1, turn
Move to
P1
Power on
Select
program
Programs
F1 BS
p
F2 STORE p
F3 REM
p
F4 MLM
p
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
power on and be measurement possible.
Power off
4/7
e
The display return to main menu.
MORE
8 Press [F2](STORE) key.
[F2]
Retaining a Coordinate
1.Store NEZ
2.Recall NEZ
9 Press [F2](Recall NEZ) key.
[F2]
Recall NEZ
HR: 300°10'20"
> Set OK?
10 Collimate P0, the former instrument point.
Collimate
P0
11 Press [F5](YES) key.
YES
[F5]
The coordinates at P1 and direction angle
toward P 0 are set.
The display return to main menu.
12 Repeat the procedure 1 ~11 as much as you
wish.
*1)To reset the instrument height or prism height, press [F5](HT) key.
5-4
Complete
NO
5 PROGRAM MODES
5.3 Remote Elevation measurement (REM)
To obtain elevation of the point at which setting the target prism is not possible, place the prism at any
point on the vertical line from the target then carry out REM procedure as follows.
Target K
VD
Prism P
G
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
Instrument
e
Prism height
1) With prism height (h) input (Example :h=1.5m)
Operating procedure
Operation
Programs
F1 BS
F2 STORE
F3 REM
F4 MLM
Display
p
p
p
p
1 Press [F3](REM) key.
[F3]
REM
Prism height
1.YES
2.NO
2 Press [F1](YES) key.
[F1]
REM
(1)Prism Height
P.h :
4/7
MORE
m
EXIT
3 Enter prism height, press [ENT] key.
Enter
P.HT
[ENT]
REM
(2)Horizontal Distance
HD :
m
MEAS
4 Collimate prism .
BS
SET
Collimate
P
5 Press [F1](MEAS) key.
[F1]
Measuring starts.
REM
(2)Horizontal Distance
HD *
< m
MEAS
5-5
SET
5 PROGRAM MODES
Horizontal distance (HD) between the
instrument and prism will be shown.
REM
(2)Horizontal Distance
HD :
123.456 m
MEAS
6 Press [F6](SET) key.
[F6]
The prism position will be decided. *1)
SET
REM
VD :
0.234 m
SET
EXIT P.h HD
7 Collimate target K.
Vertical distance (VD) will be shown. *2)
Collimate
K
REM
VD :
1.456 m
EXIT P.h HD
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
*1)To return to procedure 3 , press [F2](P.h) key.
To return to procedure 4 , press [F3](HD) key.
*2)To return to main menu, press [F1](EXIT) key.
2)Without prism height input.
Operating procedure
Operation
Programs
F1 BS
F2 STORE
F3 REM
F4 MLM
Display
p
p
p
p
4/7
MORE
1 Press [F3](REM) key.
[F3]
REM
Prism height
1.YES
2.NO
2 Press [F2](NO) key.
[F2]
REM
(1)Horizontal Distance
HD :
m
MEAS
3 Collimate prism.
Collimate
P
4 Press [F1](MEAS) key.
[F1]
Measuring starts.
REM
(1)Horizontal Distance
HD*
< m
MEAS
Horizontal distance (HD) between the
instrument and prism will be shown.
SET
REM
(1)Horizontal Distance
HD :
MEAS
5-6
123.456 m
SET
5 PROGRAM MODES
5 Press [F6](SET) key.
[F6]
The prism position will be decided.
REM
(2)Vertical Angle
V :
120°30'40"
SET
6 Collimate ground point G.
Collimate
G
REM
(2)Vertical Angle
V :
95°30'40"
SET
7 Press [F6](SET) key.
[F6]
The position of point G will be decided. *1)
REM
VD :
EXIT
Vertical distance (VD) will be shown. *2)
Collimate
K
HD
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
VD :
EXIT
*1)To return to procedure 3 , press [F2](HD) key.
To return to procedure 6 , press [F3](V) key.
*2)To return to main menu, press [F1](EXIT) AND [F5](YES) key.
5-7
V
REM
e
8 Collimate target K.
0.000 m
HD
9.876 m
V
5 PROGRAM MODES
5.4
Missing Line Measurement (MLM)
Measurement for horizontal distance (dHD), slope distance (dSD) and elevation (dVD) between two
target prisms.
MLM mode has two mods.
1.(A-B, A-C):Measurement is A-B, A-C, A-D,.............
2.(A-B, B-C):Measurement is A-B, B-C, C-D,.............
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
Prism B
e
Prism A
Instrument
Prism C
[Example] 1. (A-B, A-C)
● Procedure of 2. (A-B, B-C) mode is completely same as MLM-1 mode.
Operating procedure
Operation
Programs
F1 BS
F2 STORE
F3 REM
F4 MLM
Display
p
p
p
p
4/7
MORE
1 Press [F4](MLM) key.
[F4]
Missing Line Measurement
1.(A-B, A-C)
2.(A-B, B-C)
2 Press [F1](A-B, A-C) key.
[F1]
MLM 1
Horizontal Distance 1
HD :
m
MEAS
5-8
SET
5 PROGRAM MODES
3 Collimate prism A, and press [F1](MEAS) key.
Horizontal distance (HD) between the
instrument and prism A will be shown.
Collimate
A
[F1]
MLM 1
Horizontal Distance 1
HD *
< m
MEAS
SET
MLM 1
Horizontal Distance 1
HD :
123.456 m
MEAS
4 Press [F6](SET) key.
[F6]
SET
MLM 1
Horizontal Distance 2
HD :
m
SET
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
MEAS
5 Collimate prism B and press [F1](MEAS) key.
Collimate
B
Horizontal distance (HD) between the
instrument and prism B will be shown.
MLM 1
Horizontal Distance 2
HD *
< m
[F1]
MEAS
SET
MLM 1
Horizontal Distance 2
HD *
246.912 m
MEAS
6 Press [F6](SET) key.
[F6]
The horizontal distance (dHD) relative
elevation (dVD) and slope distance between
prism A and B.
7 To measure the distance between points A
[F2]
and C, press [F2](HD) key. *1)
MLM 1
dHD :
dVD :
dSD :
EXIT HD
SET
123.456 m
12.345 m
12.456 m
MLM 1
Horizontal Distance 2
HD :
m
MEAS
8 Collimate point C (Prism C) and press
[F1](MEAS) key.
Horizontal distance (HD) between the
instrument and prism C will be shown.
Collimate
C
[F1]
MLM 1
Horizontal Distance 2
HD :
< m
MEAS
5-9
SET
SET
5 PROGRAM MODES
MLM 1
Horizontal Distance 2
HD *
246.912 m
MEAS
9 Press [F6]( SET) key.
[F6]
The horizontal distance (dHD) relative
elevation (dVD) and slope distance between
prism A and C.
MLM 1
dHD :
dVD :
dSD :
EXIT HD
10 To measure the distance between points A
and D, repeat procedure 7 to 9. *1)
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
*1)To return to main menu, press[F1](EXIT) and [F5](YES) key.
5-10
SET
123.456 m
12.345 m
12.456 m
5 PROGRAM MODES
5.5 Line Measurement (LINE)
This mode is useful to obtain the line height.
L
VD
LH
Prism B
Off
G
P.h
Prism A
Instrument
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
HD
[Example:Input of prism height]
Operating procedure
Operation
1 Press [F6](MORE) key from programs menu
[F6]
to get the next page of programs.
Display
Programs
F1 BS
F2 STORE
F3 REM
F4 MLM
p
p
p
p
Programs
F1 LINE
F2 OFFSET
F3 EXT.LINK
p
p
p
2 Press [F1](LINE) key.
[F1]
LINE
Prism height
1 YES
2 NO
3 Press [F1](YES) key.
[F1]
LINE
Prism height
P.h:
4/7
MORE
7/7
MORE
m
EXIT
4 Input the prism height and press [ENT] key.
Input P.h
[ENT]
LINE
<STEP-1>PT A
HD:
MEAS
5-11
BS
m
SET
5 PROGRAM MODES
5 Collimate prism A and press [F1](MEAS) key.
The distance measurement will start.
Collimate
A
[F1]
Horizontal distance is displayed.
LINE
<STEP-1>P
T A
HD*
LINE
<STEP-1>PT A
HD*
< m
50.234 m
MEAS
6 Press [F6] (SET) key, and horizontal distance
[F6]
will be recorded.
SET
LINE
<STEP-1>PT B
HD:
m
SET
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
MEAS
7 Collimate prism B and press [F1](MEAS) key.
The distance measurement will start.
Collimate
B
[F1]
LINE
<STEP-1>PT B
HD*
< m
MEAS
Horizontal distance is displayed.
SET
LINE
<STEP-1>PT B
HD*
67.543 m
MEAS
8 Press [F6] (SET) key, and horizontal distance
[F6]
will be recorded.
9 Sight line point L .
LINE
VD:
HD:
Off:
EXIT LH
SET
20.123 m
38.987 m
74.123 m
Sight L
Measured data to the line point L is displayed.
VD:Vertical distance.
HD:Horizontal distance from the instrument to
L.
Off :Horizontal distance from A to L.
10 Press [F2](LH) key.
[F2]
This function is used when measuring the line
height from the ground. The procedure is as
follows :
● Sight the point on the line before pressing this
key.
● Don‘t move the horizontal tangent screw by
setting ground point G.
LINE
G-POINT
V : 30°20'10"
EXIT
5-12
SET
5 PROGRAM MODES
11 Rotate the vertical tangent screw, and sight
ground point G.
Sight G
LINE
G-POINT
V : 90°40'20"
EXIT
12 Press [F6] (SET) key, line height (LH) and
[F6]
horizontal distance (Off) are displayed.
SET
LINE
LH:
Off:
EXIT
33.765 m
27.521 m
VD
NEXT
● To finish the measurement, press the [F1](EXIT) or [ESC] key.
● To return to operation procedure 9 , press the [F2](VD) key.
● To return to operation procedure 11 , press the [F6](NEXT) key.
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
The NEXT key is used when the ground point G is not clear and you would like to check another ground
point G on the same vertical line.
5-13
5 PROGRAM MODES
5.6
Offset measurement (OFFSET)
There are four offset measurement modes in the Offset Measurement.
●
●
●
●
Angle offset
Distance offset
Plane offset
Column offset
Offset Measurement Menu
Programs
p
F1 LINE
F2 OFFSET
p
F3 EXT.LINK p
7/7
MORE
[F2](OFFSET)
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
OFFSET MEASUREMENT
1.ANGLE OFFSET
2.DIST. OFFSET
3.PLANE OFFSET
4.COLUMN OFFSET
● Outputting the Measurement Data
The results of offset measurement can be output to external device.
In offset measurement mode, the [F4] soft key which assigned (REC) will appear in measured result
display.
ANGLE OFFSET
HR: 87°55'45"
HD:
20.000 m
VD:
5.000 m
NEXT SD NEZ REC
[F4](REC)
ANGLE OFFSET
HR: 87°55'45"
HD:
20.000 m
VD:
5.000 m
> REC ?
YES
NO
[F5](YES)
ANGLE OFFSET
HR: 87°55'45"
HD:
20.000 m
VD:
5.000 m
<REC>
● Distance measurement mode of the offset measurement
Offset measurement will be done by N-time fine measurement mode.
5-14
5 PROGRAM MODES
5.6.1 Angle Offset
This mode is useful when it is difficult to set up the prism directly, for example at the center of a tree.
Place the prism at the same horizontal distance from the instrument as that of point A0 to measure.
To measure the coordinates of the center position, operate the offset measurement after setting the
instrument height/prism height.
When measuring coordinates of ground point A1
:Set the instrument height/prism height.
When measuring coordinates of point A0 : Set
the instrument height only. (Set the prism height
to 0 ).
Prism P
Prism height
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
When sighting to A0, you can select one of two
ways. [HOLD] is to fix vertical angle to the prism
position even updown the telescope position, and
[FREE] is to gear vertical angle to the updown of
telescope movement. In case following the
vertical angle to the movement of telescope,
SD(Slope Distance) and VD(Vertical Distance)
will be changed according to the movement of
telescope.
Instrument height
Occ. Point
Operating procedure
Operation
Display
Programs
F1 BS
p
F2 STORE p
F3 REM
p
F4 MLM
p
1 Press [F6](MORE) key from programs menu
[F6]
to get to the next page of programs.
Programs
F1 LINE
F2 OFFSET
F3 EXT.LINK
4/7
MORE
p
p
p
7/7
MORE
2 Press [F2](OFFSET) key.
[F2]
OFFSET MEASUREMENT
1.ANGLE OFFSET
2.DIST. OFFSET
3.PLANE OFFSET
4.COLUMN OFFSET
3 Press [F1](ANGLE OFFSET) key.
[F1]
ANGLE OFFSET
1.FREE V-ANGLE
2.HOLD V-ANGLE
5-15
5 PROGRAM MODES
4 Select the vertical angle [FREE] or [HOLD].
*1)
[F1]or [F2]
ANGLE OFFSET
HD:
m
MEAS
5 Collimate prismP, and press the [F1](MEAS)
key. *1)
Collimate
P
[F1]
HT
ANGLE OFFSET
HD*
MEAS
< m
HT
The horizontal distance from the instrument
to the prism will be measured.
6 Collimate point A 0 using the horizontal motion
Collimate
A0
ANGLE OFFSET
HR:
30°00'00"
HD:
20.000 m
VD:
0.000 m
NEXT SD NEZ REC
[F2]
ANGLE OFFSET
V :
90°00'00"
HR:
30°00'00"
SD:
20.000 m
NEXT HD NEZ REC
[F3]
ANGLE OFFSET
N :
17.321 m
E :
10.000 m
Z :
0.000 m
NEXT SD
HD REC
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
clamp and horizontal tangent screw.
7 To show the slope distance of point A0, press
the [F2](SD) key.
8 To show the coordinates, press the [F3](NEZ)
key. *2)
e
ANGLE OFFSET
HR:
20°30'40"
HD:
20.000 m
VD:
0.000 m
NEXT SD NEZ REC
*1) To set the prism height or instrument height, press the [F5](HT) key.
*2) To repeat angle offset measurement, press the [F1](NEXT) key. The display will return to step 5.
5-16
5 PROGRAM MODES
5.6.2 Distance Offset Measurement
The measurement of a place apart from a prism is possible by inputting offset horizontal distance of
front and back / right and left.
Forward HD
oHD sign
A0
RorL HD
A1
Prism height
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
Prism P
Instrument height
Occ.Point
When measuring coordinates of ground point A1:
When measuring coordinates of point A0:
Set the instrument height / prism height.
Set the instrument height only.
(Set the prism height to 0 ).
Operating procedure
Operation
Display
Programs
F1 BS
p
F2 STORE p
F3 REM
p
F4 MLM
p
1 Press [F6](MORE) key from programs menu
[F6]
to get to the next page of programs.
Programs
F1 LINE
F2 OFFSET
F3 EXT.LINK
4/7
MORE
p
p
p
7/7
MORE
2 Press [F2](OFFSET) key.
[F2]
OFFSET MEASUREMENT
1.ANGLE OFFSET
2.DIST. OFFSET
3.PLANE OFFSET
4.COLUMN OFFSET
3 Press [F2](DIST. OFFSET) key.
[F2]
DIST. OFFSET
dFR : 0.000
dRL : 0.000
Previous offset value screen will appear.
dFR: Forward/Rear offset value
dRL: Right/Left offset value
OK
5-17
m
m
INP
5 PROGRAM MODES
4 If you reset the offset value, press the
[F6]
[F6](INP) key and input the value. *1)
DIST. OFFSET
dFR : 0.000
dRL : 0.000
m
m
EXIT
5 Collimate prism using the horizontal motion
clamp and horizontal tangent screw.
Press the [F1](MEAS) key. *2)
Collimate
P
[F1]
BS
DIST. OFFSET
HD:
MEAS
m
HT
The offset measurement data will be shown.
6 To show the slope distance of point A0, press
[F2]
7 To show the coordinates, press the [F3](NEZ)
key. *3)
DIST. OFFSET
V :
90°00'00"
HR:
30°00'00"
SD:
20.000 m
NEXT HD NEZ REC
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
the [F2](SD) key.
e
DIST. OFFSET
HR:
30°00'00"
HD:
20.000 m
VD:
0.000 m
NEXT SD NEZ REC
[F3]
DIST. OFFSET
N :
17.321 m
E :
10.000 m
Z :
0.000 m
NEXT SD
HD REC
*1) To skip the input, press the [F1](OK) key.
*2) To set the prism height or instrument height, press the [F5](HT) key.
*3) To repeat the offset measurement, press the [F1](NEXT) key. The display will return to step 5.
5-18
5 PROGRAM MODES
5.6.3 Plane Offset Measurement
Measuring will be taken for the place where direct measuring can not be done, for example distance or
coordinate measuring for a edge of a plane.
Three random target points (P1, P2, P3) on a plane will be measured at first in the plane offset
measurement to determine the measured plane. Collimate the measuring target point (P0) then the
instrument calculates and displays coordinate and distance value of cross point between collimation
axis and of the plane.
Edge
P
(Prism)
(Point without prism)
P
(Prism)
P2
(Prism)
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
P3
Target heights of P1 to P3 is set to zero automatically.
Operating procedure
Operation
Display
Programs
F1 BS
p
F2 STORE p
F3 REM
p
F4 MLM
p
1 Press [F6](MORE) key from programs menu
[F6]
to get to the next page of programs.
Programs
F1 LINE
F2 OFFSET
F3 EXT.LINK
4/7
MORE
p
p
p
7/7
MORE
2 Press [F2](OFFSET) key.
[F2]
OFFSET MEASUREMENT
1.ANGLE OFFSET
2.DIST. OFFSET
3.PLANE OFFSET
4.COLUMN OFFSET
3 Press [F3](PLANE OFFSET) key.
[F3]
PLANE OFFSET
N001#
SD :
Measurement screen of three points on a
plane will be shown.
MEAS
5-19
m
HT
5 PROGRAM MODES
4 Collimate prism P1, and press the
[F1](MEAS) key.
Measuring will start.
After measuring, the second point
measurement screen will be shown.
Collimate
P1
[F1]
PLANE OFFSET
N002#
SD :
m
MEAS
same way. *1)
Collimate
P2
[F1]
Collimate
P3
[F1]
The instrument calculates and displays
coordinate and distance value of cross point
between collimation axis and of the plane. *2)
horizontal motion clamp and horizontal
tangent screw.
m
HT
PLANE OFFSET
HR:
85°30'40"
HD:
54.321 m
VD:
10.000 m
NEXT SD NEZ REC
Collimate
P0
PLANE OFFSET
HR:
75°30'40"
HD:
54.600 m
VD:
-0.487 m
NEXT SD NEZ REC
[F2]
PLANE OFFSET
V :
90°30'30"
HR:
75°30'40"
SD:
54.602 m
NEXT HD NEZ REC
[F3]
PLANE OFFSET
N :
17.321 m
E :
10.000 m
Z :
20.000 m
NEXT SD
HD REC
P0 data will be shown.
7 To show the slope distance of point P0, press
the [F2](SD) key.
8 To show the coordinates, press the [F3](NEZ)
key. *3),4)
MEAS
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
6 Collimate point P0 on the plane using the
PLANE OFFSET
N003#
SD :
e
5 Measure the second and third prism in the
HT
*1) In case the calculation of plane was not successful by the measured three points, error displays. Start
measuring over again from the first point.
*2) Error will be displayed when collimated to the direction which does not cross with the determined plane.
*3) The reflector height of the target point P0 is set to zero automatically.
*4) To repeat the offset measurement, press the [F1](NEXT) key. The display will return to step 4.
5-20
5 PROGRAM MODES
5.6.4 Column Offset Measurement
If it is possible to measure circumscription point (P1) of column directly, the distance to the center of the
column (P0), coordinate and direction angle can be calculated by measured circumscription points (P2)
and (P3).
The direction angle of the center of the column is 1/2 of total direction angle of circumscription points
(P2) and (P3).
P
P2
P3
P
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
Prism
Operating procedure
Operation
Display
Programs
F1 BS
p
F2 STORE p
F3 REM
p
F4 MLM
p
1 Press [F6](MORE) key from programs menu
[F6]
to get to the next page of programs.
Programs
F1 LINE
F2 OFFSET
F3 EXT.LINK
4/7
MORE
p
p
p
7/7
MORE
2 Press [F2](OFFSET) key.
[F2]
OFFSET MEASUREMENT
1.ANGLE OFFSET
2.DIST. OFFSET
3.PLANE OFFSET
4.COLUMN OFFSET
3 Press [F4](COLUMN OFFSET) key.
[F4]
COLUMN OFFSET
Center
HD :
Measurement screen of the center of a
column will be shown.
MEAS
4 Collimate the center of the column (P1) and
press the [F1](MEAS) key.
Measuring will start.
After the measurement, angle measuring
display of the left side (P2) will be shown.
Collimate
P1
[F1]
m
HT
COLUMN OFFSET
Left
HR :
90°30'40"
SET
5-21
5 PROGRAM MODES
5 Collimate the left side of the column (P2) and
press the [F6](SET) key.
After the measurement, angle measuring
display of the right side (P3) will be shown.
Collimate
P2
[F6]
COLUMN OFFSET
Right
HR :
95°30'40"
SET
and press the [F6](SET) key.
After the measurement, the distance between
the instrument and center of the column (P0)
will be calculated and displayed.
Collimate
P3
[F6]
COLUMN OFFSET
HR:
90°30'40"
HD:
10.321 m
VD:
0.886 m
NEXT SD NEZ REC
[F2]
COLUMN OFFSET
V :
85°30'30"
HR:
90°30'40"
SD:
10.999 m
NEXT HD NEZ REC
[F3]
COLUMN OFFSET
N :
17.321 m
E :
10.962 m
Z :
0.886 m
NEXT SD
HD REC
7 To show the slope distance of point P0, press
the [F2](SD) key.
key. *1)
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
8 To show the coordinates, press the [F3](NEZ)
e
6 Collimate the right side of the column (P3)
*1) To repeat the offset measurement, press the [F1](NEXT) key. The display will return to step 4.
5-22
5 PROGRAM MODES
5.7 External Link (GPT-8000A series)
You can use compatible communication command of AP-L1A for GPT-8000A series. In this process
carry out setting for remote control system RC-2II using together.
5.7.1 Starting compatible communication program of AP-L1A
Operating procedure
Operation
Display
Programs
F1 BS
F2 STORE
F3 REM
F4 MLM
1 Press the [F6](MORE) key to get the next
[F6]
page.
p
p
p
p
4/7
MORE
Programs
F1 LINE
P
F2 OFF SET P
F3 EXT.LINK P
7/7
2 Press the [F3](EXT.LINK) key.
[F3]
EXTERNAL LINK
1 Execute
2 Setting
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
The compatible program EXTERNAL LINK
will start.
e
MORE
5.7.2 Setting for the communication
Decide transmit course and parameters before executing communication.
(1)Setting communication course
Select a communication course according to the using optional device.
1) Cable
:
In case connecting personal computer or other than Topcon's designated wireless
modem to the RS-232C connector.
2) RADIO MODEM :
In case connecting Topcon's designated wireless modem.
3) RC
:In case attaching remote controller handle unit RC-2H to carry out optical
communication between the remote controller RC-2RII and the GPT-8000A series.
Operating procedure
Operation
Execute Section 5.7.1“Starting compatible
communication program of AP-L1A” to start
[EXT.LINK] of compatible communication
program of AP-L1.
Display
EXTERNAL LINK
1 Execute
2 Setting
1 Press the [F2](Setting) key.
[F2]
Setting
1 CABLE/RADIO MODEM/RC
2 PARAMETER(CABLE)
3 PARAMETER(RC)
4 PARAMETER(RADIO MODEM)
2 Press the [F1] key to select [CABLE/RADIO
[F1]
CABLE/RADIO MODEM/RC
MODEM/RC]
CABLE
SET
5-23
↑
↓
EXIT
5 PROGRAM MODES
3 Select communication course by pressing the
[F3]
or
[F4]
[F3](↑) or [F4](↓) key.
(Sample setting :RC)
CABLE/RADIO MODEM/RC
RC
SET
4 Press the [F1](SET) key to decide.
[F4]
↑
↓
EXIT
Setting
1 CABLE/RADIO MODEM/RC
2 PARAMETER(CABLE)
3 PARAMETER(RC)
4 PARAMETER(RADIO MODEM)
● To cancel the setting, press the [F6](EXIT)key or the [ESC] key.
(2)Setting Parameters of Cable (RS-232C)
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
In case connecting Topcon's designated wireless modem, simply select communication course as
"RADIO MODEM" it is enough to do setting of parameter automatically.
In case connecting personal computer or other than Topcon's designated wireless modem, it is required
to do parameters setting for RS-232C before using.
Parameters
1) SPEED (Baud rate)
Sets communication speed
Set items: 1200, 2400, 4800, 9600bps
2) BIT FORMAT
Select the communication format.
Set items:
Bit length
:
7 : D7,
8 : D8
Stop bit
:
1 : S1,
2 : S2
Parity bit
:
NONE, ODD, EVEN
3) DELIMITER (Terminate)
Selecting CR (Carriage return), or LF (Line feed) will be added at the end of data.
Set items:
ETX, ETX+CR, ETX+CRLF
4) RTS (Control of signal line)
Select default output of signal line
Set items:
Hi
: High level (Normal)
Low
: Low level (It becomes High level only when data are transmitted.)
5) REC TYPE
Select the option to record the data for the distance measurement.
REC-A : Measure the distance again and record the updated distance.
REC-B : Record the data for the last distance measurement on the display.
Operating procedure
Operation
Display
EXTERNAL LINK
1 Execute
2 Setting
Execute Section 5.7.1“Starting compatible
communication program of AP-L1A” to start
[EXT.LINK] of compatible communication
program of AP-L1.
1 Press the [F2](Setting) key.
[F2]
5-24
Setting
1 CABLE/RADIO MODEM/RC
2 PARAMETER(CABLE)
3 PARAMETER(RC)
4 PARAMETER(RADIO MODEM)
5 PROGRAM MODES
2 Press the [F2] key to select [2PARAMETER
[F2]
(CABLE)].
Speed setting screen will appear.
SPEED
9600
↑
SET
3 Press the [F3](↑) or [F4](↓) key to select baud
[F3]
or
[F4]
[F1]
rate then press the [F1](SET) key to decide.
[F3]
or
[F4]
[F1]
D8
[F3]
or
[F4]
[F1]
↑
↓
EXIT
↑
↓
EXIT
↓
EXIT
↓
EXIT
e
RTS
SET
6 Set RTS in the same way.
7 Set REC TYPE in the same way.
NONE
ETX
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
[F3]
or
[F4]
[F1]
S1
TERMINATE
SET
5 Set DELIMITER (Terminate) in the same way.
EXIT
BIT FORMAT
SET
4 Set bit format in the same way.
↓
Hi
↑
REC TYPE
SET
REC-A
↑
Setting
1 CABLE/RADIO MODEM/RC
2 PARAMETER(CABLE)
3 PARAMETER(RC)
4 PARAMETER(RADIO MODEM)
● To cancel the setting, press the [F6](EXIT)key or the [ESC] key.
(3)Setting Parameters of RC
Attach the remote controller handle unit RC-2H and set the parameters for communication with the
remote controller system RC-2II.
Parameters
1) Channel
Sets communication channel
The same channel must be set for GPT-8000A series and RC-2RII.
Set channels : 1, 2, 3
2) DELIMITER (Terminate)
Selecting CR (Carriage return), or LF (Line feed) will be added at the end of data.
Set items:
ETX, ETX+CR, ETX+CRLF
3) Retry
This is a method to retry setting for sending data again during communication with remote controller
RC-2II.
Set items:Standard, Divided
Standard: Gives good for fast communication.
This is offered in normal condition.
Divided : Using in bad condition such in long distance, bad condition of sight, strong
heat simmer, or happens cut off the optical path, in such cases it takes long
time for communication or results failure. You are offered to set [Divided] item.
5-25
5 PROGRAM MODES
4) REC TYPE
Select the option to record the data for the distance measurement.
REC-A :
Measure the distance again and record the updated distance.
REC-B :
Record the data for the last distance measurement on the display.
Operating procedure
Operation
Display
EXTERNAL LINK
1 Execute
2 Setting
Execute Section 5.7.1“Starting compatible
communication program of AP-L1A” to start
[EXT.LINK] of compatible communication
program of AP-L1.
1 Press the [F2](Setting) key.
[F2]
Setting
1 CABLE/RADIO MODEM/RC
2 PARAMETER(CABLE)
3 PARAMETER(RC)
4 PARAMETER(RADIO MODEM)
2 Press the [F3] key to select [3 PARAMETER
[F3]
CHANNEL
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
(RC)].
SET
3 Select a channel by pressing the [F3](↑) or
[F3]
or
[F4]
[F1]
[F4](↓) key then press the [F1](SET) key.
[F3]
or
[F4]
[F1]
[F4](↓) key then press the [F1](SET) key.
[F3]
or
[F4]
[F1]
key then press the [F1](SET) key
[F3]
or
[F4]
[F1]
↓
EXIT
ETX
↑
Standard
↑
↓
EXIT
↓
EXIT
REC-A
↑
Setting
1 CABLE/RADIO MODEM/RC
2 PARAMETER(CABLE)
3 PARAMETER(RC)
4 PARAMETER(RADIO MODEM)
● To cancel the setting, press the [F6](EXIT)key or the [ESC] key.
(4)Setting Parameters for Radio Modem
Set the parameters for Radio Modem.
Parameters
1) Channel (Only for certain market)
Sets communication channel
The same channel must be set for GPT-8000A series and Radio Modem.
Set channels : A, B, C......
5-26
EXIT
REC TYPE
SET
6 Set REC TYPE in the same way.
↓
RETRY
SET
5 Select Retry by pressing the [F3](↑) or [F4](↓)
↑
TERMINATE
SET
4 Select Terminate by pressing the [F3]( ↑) or
1
5 PROGRAM MODES
2) REC TYPE
Select the option to record the data for the distance measurement.
REC-A : Measure the distance again and record the updated distance.
REC-B : Record the data for the last distance measurement on the display.
Operating procedure
Operation
Display
EXTERNAL LINK
1 Execute
2 Setting
Execute Section 5.7.1“Starting compatible
communication program of AP-L1A” to start
[EXT.LINK] of compatible communication
program of AP-L1.
1 Press the [F2](Setting) key.
[F2]
Setting
1 CABLE/RADIO MODEM/RC
2 PARAMETER(CABLE)
3 PARAMETER(RC)
4 PARAMETER(RADIO MODEM)
2 Press the [F4] key to select PARAMETER
[F4]
CHANNEL
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
(RADIO MODEM).
(The channel setting display is provided
only for certain market)
SET
[F3]
or
[F4]
[F1]
[F3]
or
[F4]
[F1]
↑
↓
EXIT
↓
EXIT
REC TYPE
SET
3 Set REC TYPE in the same way.
A
REC-A
↑
Setting
1 CABLE/RADIO MODEM/RC
2 PARAMETER(CABLE)
3 PARAMETER(RC)
4 PARAMETER(RADIO MODEM)
5.7.3 Carrying out Communication
Operating procedure
Operation
Display
EXTERNAL LINK
1 Execute
2 Setting
Execute Section 5.7.1“Starting compatible
communication program of AP-L1A” to start
[EXT.LINK] of compatible communication
program of AP-L1.
1 Press the [F1](Execute) key.
[F1]
The display as showing right says the
compatible communication program of APL1A is executed and communication
command can be accepted.
EXTERNAL LINK (RC)
Remote control is being done
from the controller.
EXIT
● To stop the communication, press the [F6](EXIT) or [ESC] key.
5-27
6 MEMORY MANAGE MODES
6
MEMORY MANAGE MODES
2002-07-10 15:30:40
[Press [F3] key.]
Prog Std Mem Com Adj Para
MEMORY MANAGE MODES
The following items are available in this mode.
1. Display the memory size and memory free.
2. Protecting files
3. Delete files
4. Rename files
5. Copy files
6. Initialize memory.
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
6.1
e
Memory manage
F1 Internal memory
F2 Card memory
View Internal Memory and Card Memory Status
When selecting the internal memory or card memory, the GPT-8000A/8000 will display the memory
size, the amount of free memory and the expiration date for the internal lithium battery.
The display information format is the same for the card memory except that the card name appears at
the top of the display. The card name can be eleven characters in length, alpha or numeric.
Operating procedure
Operation
Display
Memory manage
F1 Internal memory
F2 Card memory
1 Select Internal memory or Card memory by
Memory size
Memory free
Battery expire
Init.
pressing [F1] or [F2] key.
The memory capacity and the remaining
memory capacity are shown.
Example: Internal Memory
2 Press [F6](File) key.
[F6]
Each File status (File name, File name
extension, Used memory capacity, Date) are
shown.
Press the [ESC] key to return to the main
menu icons.
6-1
1967KByte
1951KByte
2004/01
File
JIS
.DAT
1597
TOPCON .DAT
1089
FC7
.TXT
2450
HILL
.DAT
31777
Pro
Ren
Del Copy
12-25
10-05
09-11
08-19
↑ ↓
6 MEMORY MANAGE MODES
6.2 Protect a File
Protecting one or more files can be accomplished with the file protection mode. When a file is
protected, an asterisk appears after the file name extension. If a file is protected, you can not delete the
file unless you remove the file protection.
● Note:All the files stored will be erased by initializing the memory, even if the files are protected.
Operating procedure
Operation
1 Proceed Chapter 6.1.
2 Select a file using [F5](↑) key or [F6](↓) key.
Display
JIS
.DAT
1597
TOPCON .DAT
1089
FC7
.TXT
2450
HILL
.DAT
31777
Pro
Ren
Del Copy
12-25
10-05
09-11
08-19
↑ ↓
Select a
file
Protect
3 Press [F1](Pro) key.
[F1]
.DAT]
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
[TOPCON
4 Press [F5](ON) key. *1)
ON
OFF
[F5]
The file is protected and display will return to
file name.
*1) When you cancel the protection, repeat the procedure above mentioned and select [F6](OFF) key.
6.3 Rename a File
Files can be renamed on the card or in internal memory. When renaming a file, the old file name
appears above the input line for the new file name. When typing in the new name, you do not have to
input the file extension.
Operating procedure
Operation
1 Proceed Chapter 6.1.
2 Select a file using [F5](↑) key or [F6](↓) key.
Display
JIS
.DAT
1597
TOPCON .DAT
1089
FC7
.TXT
2450
HILL
.DAT
31777
Pro
Ren
Del Copy
12-25
10-05
09-11
08-19
↑ ↓
Select a
file
3 Press [F2](Ren) key.
[F2]
Rename
Old name [TOPCON
New name [
Alpha
4 Enter a new file name within 8 characters.
Enter
name
Press [ENT] key. *1)
[ENT]
*1) Refer to Chapter 2.9 “How to Enter Numerals and Alphabet Letters” .
6-2
SPC
← →
.DAT]
]
6 MEMORY MANAGE MODES
6.4
Deleting a File
The delete mode erases a file from internal memory or the card memory. If a file is protected, the file
can not be erased. File protection must be removed before you can delete a file. Only one file can be
erased at a time .
Operating procedure
Operation
1 Proceed Chapter 6.1.
2 Select a file using [F5](↑) key or [F6](↓) key.
Display
JIS
.DAT
1597
TOPCON .DAT
1089
FC7
.TXT
2450
HILL
.DAT
31777
Pro
Ren
Del Copy
12-25
10-05
09-11
08-19
↑ ↓
Select a
file
3 Press [F3](Del) key.
Delete
[F3]
.DAT]
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
[TOPCON
4 Confirm the file name, and press [F5](YES)
key.
YES
NO
[F5]
● If the file is protected, the file can not be erased. Erase the file after canceling the protection.
6.5
Copy a File
A file can be copied from internal memory to the card memory and vice verse. The copy mode only
copies files to the root directory. Files can not be copied into other directories.
Example : Copying a file in internal memory to card memory.
Operating procedure
Operation
Display
MEMORY manage
F1 Internal memory
F2 Card memory
1 Press [F1] key to choose Internal memory.
[F1]
2 Select a file using [F5](↑) key or [F6](↓) key.
Select a
file
3 Press [F4](Copy) key.
[F4]
JIS
.DAT
1597
TOPCON .DAT
1089
FC7
.TXT
2450
HILL
.DAT
31777
Pro
Ren
Del Copy
12-25
10-05
09-11
08-19
↑ ↓
File Copy
[HILL
.DAT]
YES
4 Confirm the file name, and press [F5](YES)
[F5]
key.
6-3
NO
6 MEMORY MANAGE MODES
6.6 Initializing Memory
The initialize memory option will erase ALL FILES in either the internal memory or card memory and
files cannot be retrieved.
Example: Initializing card memory
Operating procedure
Operation
Display
MEMORY manage
F1 Internal memory
F2 Card memory
[F2]
2 Press [F1](Init) key.
[F1]
Card name [TOPCON
]
Memory size
1967KByte
Memory free
1951KByte
Card battery expire
11/99
Init
File
e
1 Press [F2] key to select card memory.
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
RAM card memory format
3 Confirm the display, and press [F5](YES) key.
[F5]
Initializing will be executed.
Card
name
[ENT]
Card memory expire will be shown.
5 Confirm the display, and press [F5](YES) key.
*1)
[
SPC
]
←
→
Card memory expire
Today
1999-11
Validity
+4.0 year
Until
2003-11
YES
NO
[F5]
The display returns to main menu.
*1) To reset the card memory expire, press [F6] (NO) key and input new data.
6-4
NO
Card name
Alpha
4 Input card name and press [ENT] key.
YES
7 COMMUNICATION MODES
7
COMMUNICATION MODES
2002-07-10 15:30:40
[Press [F4] key.]
Prog Std Mem Com Adj Para
COMMUNICATION MODES
The communication modes are used for setting the Baud rate (Protocol), receiving a file (Data file in)
and sending a file (Data file out). A data transfer program on your PC that supports (YMODEM) will be
necessary to send or receive data files.
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
7.1
e
Communication
F1 Protocol
F2 Data file in
F3 Data file out
Setting of PROTOCOL
To transfer data files to and from the GPT-8000A/8000 Series and PC, the Baud rates must be the
same. The Baud rate selections are 600, 1200, 2400, 4800, 9600, and 19200.
To set the protocol for measured data transferring, refer to Chapter 8 “PARAMETERS SETTING
MODE” ..
Operating procedure
Operation
Display
Communication
F1 Protocol
F2 Data file in
F3 Data file out
1 Press the [F1](Protocol) key for protocol.
[F1]
Communication
Speed
600
4800
←
2 To select the Baud rate, use the arrow key`s
[F3-F6] to highlight your choice. When the
correct Baud rate is highlighted, press the
[ENT] key.
[F3] to[F6]
[ENT]
7-1
Communication
F1 Protocol
F2 Data file in
F3 Data file out
1200 2400
9600 19200
→
↑
↓
7 COMMUNICATION MODES
7.2 Data File In
When transferring data files from a PC to the GPT-8000A/8000 Series, the file received into the main
directory. Data files CANNOT be received into a subdirectory. Data files CANNOT be transferred to the
card memory. Files can only be transferred to the internal memory and then copied onto the card.
Operating procedure
Operation
Display
Communication
F1 Protocol
F2 Data file in
F3 Data file out
Make sure the instrument is ready and
waiting for the data file before you command
the PC to send the file.
1 Press [F2](Data file in) key.
2 Command the PC to send the file at this time.
[F2]
File name, amount of received data (Byte) /
Capacity of the file (Byte) and percentage of
proceeding will be displayed.
When the transfer is complete, the display will
return to the main menu icons.
Data file in
[TOPCON
8676
(0%)
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
0/
.DAT]
7.3 Data File Out
Transferring a file from the GPT-8000A/8000 internal memory or card memory to the PC is also
possible.
Operating procedure
Operation
Make sure the PC is ready and waiting before
the GPT-8000A/8000 sends the file.
Communication
F1 Protocol
F2 Data file in
F3 Data file out
1 Press [F3](Data file out) key.
2 Press [F1](Internal memory) or [F2](Card
memory) key and press [ENT] key.
Example: Internal memory
3 Select a file by pressing [F5](↑) or [F6](↓) key
and press [ENT] key.
File name, amount of sent data(Byte) /
Capacity of the file (Byte) and percentage of
proceeding will be displayed.
When the transfer is complete, the display will
returns to the file menu.
Display
[F3]
Data file out
F1 Internal memory
F2 Card memory
[F1] to[F2]
[ENT]
JIS
.DAT
TOPCON .DAT
FC7
.TXT
HILL
.DAT
Data file out
Select
a file
[ENT]
Data file out
[TOPCON
0/
7-2
1597
1089
2450
31777
↑
12-25
10-05
09-11
08-19
↓
.DAT]
1089 (0%)
8 PARAMETERS SETTING MODE
8
PARAMETERS SETTING MODE
2002-07-10 15:30:40
[Press [F6] key.]
Prog Std Mem Com Adj Para
PARAMETERS SETTING MODE
In this mode, setting of parameters regard with measuring, displaying and
communications will be done.
When a parameter is changed and set, the new value is stored into memory.
Press [F6] key from the main menu icons, the following display will be shown.
The parameter modes is classified in Measurement and Communication.
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
8.1
e
Parameters
F1 Measurement
F2 Communication
F3 Password
Parameter Setting Options
8.1.1 Parameters for Measurement and Display
Menu
Selecting Item
Contents
deg / gon / mil
Select degree(360°), gon(400G) or mil (6400M) for the
measuring angle unit to be shown on the display.
OFF / ON
Select the minimum display angle reading ON or OFF.
GPT-8001A/8001 [ OFF:1" / ON:0.5" ]
GPT-8002A/8002 [ OFF:1" / ON:0.5" ]
GPT-8003A/8003 [ OFF:5" / ON:1" ]
GPT-8005A/8005 [ OFF:5" / ON:1" ]
Minimum angle of GPT-8002A/8002 will be differed by the
market.
OFF / Vertical / Dual
Select the tilt sensor option for OFF, (1axis) vertical only or
(2axis) vertical and horizontal.
4.Err. corr.
OFF / ON
Select the error correction ON or OFF for collimation and error
adjustment.
Note:
Perform this item after complete section 9.4.
For more information, refer to Section 9.4 “Adjustment of
Compensation Systematic Error of Instrument” and Section
9.5 “Showing Constant List and Switch ON/OFF
Compensation Systematic Error of Instrument” .
5.V -0
Zenith / Level
Select the vertical angle reading for Zenith 0 or Horizontal 0.
6.HAmem
CLEAR / MEMORY
It is able to retain presetting angle after turning power
off.(MEMORY)
Note:
After changing this parameter, turn the power switch off once.
7.Turn
Fine / Normal /
Coarse
Select the stopping accuracy of automatic rotation to required
angle.
Fine:3"
Normal :5"
Coarse:10"
8.Auto.colli
Fine / Normal /
Coarse
Select the accuracy of automatic collimation.
1.Ang. Unit
2.Min.Angle
3.Tilt
8-1
8 PARAMETERS SETTING MODE
METER /FEET
Select the distance measuring unit Meter or Feet shown on
the display.
10.C.F. m/ft
Us.f /Intl.f
Select the meter / feet conversion factor.
US SURVEY feet
1m =3.280833333333333 ft.
INTERNATIONAL feet
1m =3.280839895013123 ft.
11.Min. Dist.
OFF / ON
Select OFF or ON for the minimum distance in fine mode.
OFF:1mm :ON: 0.2mm
12.S/A buzz.
OFF / ON
13.W-corr.
OFF/ 0.14 / 0.20
Select the coefficient correction for refraction and earth
curvature. Selections for the refraction coefficient are;
OFF (No correction), K=0.14 or K=0.20.
14.N/E/Z mem
OFF / ON
Select the option to store the coordinates (NEZ) for the
occupied point when power is turned off.
15.N/E- ord.
NEZ / ENZ
Select the display format in the coordinate measurement
mode for NEZ or ENZ.
16.Temp. Unit
17.Pres. Unit
18.R/L Lock
19.m/ft Lock
20.Date
21.A. P. OFF
22.Heater
23.EDM wait
24.L.P.OFF
(Only for laser
plummet model)
e
Select the Audio tone OFF or ON for the Set Audio Mode.
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
9.Dist. Unit
°C / °F
Select the temperature unit for the atmospheric correction.
mmHg/inHg/hPa
Select the air pressure unit for the atmospheric correction .
OFF / ON
Prohibit switching angle right or left by soft key in angle
measurement mode
OFF : Switching is possible ON : Prohibition
OFF / ON
Prohibit switching meter unit or feet unit.
OFF : Switching is possible ON : Prohibition
Date/Month/ Year
Month / Date /Year
Year / Month /Date
Select the date format shown on the display.
(Date/Month/ Year), (Month / Date / Year) or (Year / Month /
Date)
OFF / ON 99
The auto power off function can be turned OFF or set ON.
OFF : not use ON :1 to 99 minutes (numeric key)
OFF / ON
The heater option for both display units can be turned OFF or
ON.
OFF / ON (01 to 99)
EDM cut off time after distance measurement is completed
can be changed.
OFF : EDM is cut off immediately after measuring
ON : EDM is cut off after 1 to 99 minutes.
manual /
auto 01 to 99
Laser Plummet function can be turned OFF automatically.
manual ON/OFF by pressing soft key.
auto 01~99 : Laser Plummet function is cut off after 1~99
minutes. (numeric key)
8.1.2 Parameters for communication
For GPT-8000 series
Factory default settings are indicated with underlines.
Menu
Selecting Item
Contents
1.B. Rate
1200 / 2400 / 4800 /
9600
Select the baud rate.
2.Data. L
7/8
Select the data length seven digits or eight digits.
3.Parity
none / odd / even
Select the parity bit.
8-2
8 PARAMETERS SETTING MODE
4.Stop Bit
1/2
Select the stop bit.
5.Delimit
ETX / CRLF
Select the option OFF or ON for carriage return and line feed
when collecting measurement data with a computer.
6.REC-A/B
A/B
Select the option to record the data.
REC-A : The measurement is started and new data is output.
REC-B : The data being displayed is output.
7.Protocol
OFF / ON
When communicating to an external device, the protocol for
handshaking can omit the [ACK] coming from the external
device so data is not sent again.
OFF : Omit the [ACK]
ON : Standard
8.NEZ-REC
Std / Expand
Record coordinates in standard or Data with slope distance
and horizontal angle data.
For GPT-8000A series
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
The following settings are effective for standard measurement modes only.
You are requested to set each time of each application such as EXTERNAL LINK (in Program
modes) or other application software.
Serial port.
Menu
S.Port
Selecting Item
RS232C / RC
Contents
Selecting serial port, RS-232C connector 1(6pins) or Remote
controller handle unit RC-2H.
Setting parameters for RS232C
Menu
Selecting Item
Contents
1200 / 2400 / 4800 /
9600
Select the baud rate.
7/8
Select the data length seven digits or eight digits.
none / odd / even
Select the parity bit.
1/2
Select the stop bit.
ETX / CRLF
Select the option OFF or ON for carriage return and line feed
when collecting measurement data with a computer.
A/B
Select the option to record the data.
REC-A : The measurement is started and new data is output.
REC-B : The data being displayed is output.
7.Protocol
OFF / ON
When communicating to an external device, the protocol for
handshaking can omit the [ACK] coming from the external
device so data is not sent again.
OFF : Omit the [ACK]
ON : Standard
8.NEZ-REC
Std / Expand
Record coordinates in standard or Data with slope distance
and horizontal angle data.
OFF / ON
Selecting additional information of utility to measuring data
such as tracking status or not.
If such utility is selected, electric circular level graphic will not
be displayed whenever tilted over.
OFF :No additional information
ON :Additional information
1.B. Rate
2.Data. L
3.Parity
4.Stop Bit
5.Delimit
6.REC-A/B
9.Trk Stat
8-3
8 PARAMETERS SETTING MODE
Setting parameter for RC
Menu
Selecting Item
Contents
1/2/3
Sets communication channel when using RC-2H.
15 / 30
Selecting the vertical range for searching a prism when using
with RC-2H.
15 : ±15°
30 : ±30°
S/M
Selecting the number of the RC-2RII to use one or more than
one when using with RC-2H.
S : Single RC-2RII use
M : Multiple RC-2RII use
4.Retry
Std. / Div.
Selecting the method of the data re-transmitting.
Std (Standard) : This is offered in normal condition.
Div.(Divided)
: Using in bad condition such in long
distance, bad condition of sight, strong
heat simmer.
5.Delimit
ETX / CRLF
Select the option OFF or ON for carriage return and line feed
when collecting measurement data with a computer.
1.Channel
2.V.Search
6.REC-A/B
7.NEZ-REC
8.Trk State
9. B. Rate
10.Data. L
11.Parity
12.Stop Bit
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
3.RC
A/B
Select the option to record the data.
REC-A :The measurement is started and new data is output.
REC-B :The data being displayed is output.
Std / Expand
Record coordinates in standard or Data with slope distance
and horizontal angle data.
OFF / ON
Selecting additional information of utility to measuring data
such as tracking status or not.
If such utility is selected, electric circular level graphic will not
be displayed whenever tilted over.
OFF :No additional information
ON :Additional information
4800
Fixed
8
Fixed
none
Fixed
1
Fixed
8.2 Setting Parameters
8.2.1 Parameters for Measurement and Display
[Example setting]
S/A BUZZER: OFF, Atmospheric pressure: hPa
Operating procedure
Operation
1 Press the [F6] key from the main menu icons.
[F6]
Parameters
F1 Measurement
F2 Communication
F3 Password
2 Press the [F1] (Measurement) key.
[F1]
Parameters (Measurement)
Ang.Unit [ deg ] gon mil
Min.Angl
OFF
[ ON ]
Tilt
[ OFF ] 1axis 2axis
SET
EXIT
<->
↑ ↓
8-4
Display
8 PARAMETERS SETTING MODE
3 Select the menu by pressing [F6]( ↓) key.
[F6]
Parameters (Measurement)
S/A buzz. OFF [ ON ]
W-corr.
OFF [ 0.14 ] 0.20
N/E/Z mem OFF [ ON ]
SET
EXIT
<->
↑ ↓
4 Press [F3](←) key, and select OFF.
[F3]
Parameters (Measurement)
S/A buzz.[ OFF ] ON
W-corr.
OFF [ 0.14 ] 0.20
N/E/Z mem
OFF [ ON ]
SET
EXIT
<->
↑ ↓
5 Select the atmospheric pressure menu by
[F6]
Parameters (Measurement)
Pres.Unit [ mmHg ] inHg
hPa
R/L Lock [ OFF ] ON
m/ftLock [ OFF ] ON
SET
EXIT
<->
↑ ↓
[F4]
Parameters (Measurement)
Pres.Uni mmHg inHg
[hPa ]
R/L Lock [ OFF ] ON
m/ftLock [ OFF ] ON
SET
EXIT
<->
↑ ↓
(Example: S/A buzz.))
pressing [F6]( ↓) key.
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
6 Press [F4](→) key twice, and select hPa.
7 Press [F1](SET) key.
[F1]
Parameters (Measurement)
> Set OK?
8 Press [F5](YES) key. *1)
YES
NO
[F5]
The display returns main menu.
*1) To cancel the setting, press [F6](NO) key.
8.2.2 Parameters for Communication
Sample setting: GPT-8000A series-RS232C
Operating procedure
Operation
1 Press the [F6] key from the main menu icons.
[F6]
Parameters
F1 Measurement
F2 Communication
F3 Password
2 Press the [F2] (Communication) key.
[F2]
Parameters (Communication)
1 Serial Port RS232C/RC
2 Set RS232C
3 Set RC
The screen in the right is indicated only for
GPT-8000A series.
Display
This menu is only for GPT-8000A series
8-5
8 PARAMETERS SETTING MODE
3 Press the [F2](Set RS232C) key.
[F2]
The next steps are same as Section 8.2.1Parameters Setting for communication, refer
to the section 8.2.1.
Parameters (Communication)
B.Rate [1200] 2400 4800 9600
Data.L [ 7 ] 8
Parity
none
odd [even]
SET I.GTS
<->
↑ ↓
● The setting will reset to the default settings by pressing the [F2](I.GTS) key.
(1200baudrate, Even, Stop 1, Delimit ETX, Rec-A Protocol ON, NEZ-REC Standard) Factory default
settings are indicated with underlines in Chapter 8.1.2 “Parameters for communication” .
● In the setting of RC, the settings of Baudrate, data length, Parity and Stop are fixed.
They will be indicated on the screen for your reference.
Though Protocol is not indicated, it is fixed to OFF.(GPT-8000A series)
8.2.3 Password Option
Establishing a Password
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
A password can be set in the GPT-8000A/8000 series to secure the use of the instrument. Once a
password is established the user can disable the option or change the password. Once a password
established and the option is turned off, the password will always remain in memory. When turning on
the instrument after a password-input screen appears before the self-test mode. Type in your password
and press the [ENTER] to continue.
A maximum of 10 numeric digits can be entered for a password. All zeros (0000000000) or 9`s
(9999999999) are invalid passwords. If 10 unsuccessful attempts are made to input a password, the
instrument will shut off automatically.
Establishing a Password for the first time.
The instructions below show how to establish a password for the first time.
Operating procedure
Operation
1 From the main menu icons, press [F6](Para)
to access the parameters option menu.To
access the password option, press
[F3](Password).
Display
[F6]
Parameters
F1 Measurement
F2 Communication
F3 Password
[F3]
Password
[OFF]
EXIT CHANGE
2 The password option screen will appear.
Password
Input a password
[
When accessing the password option for the
first time, the [OFF] indicator will appear on
the upper left corner of the screen. To
establish a password you can press the
[F5](ON) key to turn on the option and
establish a password.
EXIT
OFF
]
BS
[F5]
3 The password-input screen will appear. At the
Password
Input again (confirmation)
[
]
blinking cursor type in your password and
press the [ENT] key.
IMPORTANT:
DON'T FORGET YOUR PASSWORD.
WRITE THE PASSWORD DOWN ON
A PIECE OF PAPER AND PUT IN A
SAFE PLACE. ONCE A PASSWORD
IS STORED YOU CAN NOT ERASE IT
FROM MEMORY.
ON
EXIT
Type
password
[ENT]
8-6
BS
8 PARAMETERS SETTING MODE
4 The confirmation screen will appear to
confirm your password.
Type the password in once again and press
[ENT].
Type
password
[ENT]
Password
[ON]
EXIT CHANGE
ON
OFF
5 The password option screen will appear once
again for 2 seconds and will automatically
change to the main menu icons. Notice the
[ON] indicator is now shown on the display.
Turning OFF the Password
After a password is established, you can disable the password option. Once you disable the option, the
password-input screen will not appear every time you power on the instrument.
Turning OFF the Password Option
Operation
[F6]
Parameters
F1 Measurement
F2 Communication
F3 Password
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
to access the parameters option menu.
Press [F3](Password) to access the password
option.
Display
e
Operating procedure
1 From the main menu icons, press [F6](Para)
[F3]
Password
Input a password
[
EXIT
2 Type in your password and press [ENT].
]
BS
Type
password
[ENT]
3 The password option screen will appear. The
Password
[ON]
indicator on the upper left side of the screen
will show [ON].
EXIT CHANGE
4 To turn off the password option, press
[F6]
[F6](OFF). The [ON] indication changes to
[OFF] and the screen automatically changes
back to the main menu icons.
Password
[OFF]
EXIT CHANGE
8-7
ON OFF
ON OFF
8 PARAMETERS SETTING MODE
Changing a Password
Once a password is established, you can change the original password. The new password takes the
place of the original password in memory.
Changing the Password
Operating procedure
Operation
1 From the main menu icons, press [F6](Para)
to access the parameters option menu.
Press [F3](Password) to access the password
option.
Display
[F6]
Parameters
F1 Measurement
F2 Communication
F3 Password
[F3]
Password
Input a password
[
]
2 Type in your password at the blinking cursor
Type
password
[ENT]
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
and press [ENT].
3 The password option screen will appear.
Press the [F2](Change) to change the current
password.
BS
e
EXIT
Password
[ON]
EXIT CHANGE
[F2]
Password
Input a password
[
EXIT
4 The password-input screen will appear. At the
blinking cursor type in the new password and
press the [ENT] key.
IMPORTANT:
DON'T FORGET YOUR PASSWORD.
5 The confirmation screen will appear to
confirm your new password.
Type in the new password once again and
press [ENT].
Type
password
[ENT]
[F1]
again.
Press the [F1](EXIT) to return back to the
main menu icons.
8-8
BS
BS
Password
[ON]
EXIT CHANGE
6 The password option screen will appear once
]
Password
Input again (confirmation)
[
]
EXIT
Type
password
[ENT]
ON OFF
ON OFF
9 CHECK AND ADJUSTMENT
9
CHECK AND ADJUSTMENT
9.1
Checking and Adjusting of Instrument Constant
Note: Each of the Prism mode and Non-prism mode has instrument constant.
You must obtain the instrument constant of prism mode. If you reset the instrument
constant of the prism mode, you must vary the non-prism constant (Non-prism-short, Nonprism-long) by the same quantity as the amount of increase or decrease of the instrument
constant of the prism mode.
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
Normally, the instrument constant does not have discrepancy. It is recommended you measure and
compare with an accurately measured distance at a location where the precision is specifically
monitored on a consistent basis. If such a location is not available, establish your own base line over
20m (when purchasing the instrument) and compare with the data measured with newly purchased
instrument.
In both cases note that the setup displacement of the instrument position over the point, the prism,
baseline precision, poor collimation, atmospheric correction, and correction for refraction and earth
curvature determine the inspection precision. Please keep in mind these points.
Also, when providing a base line in a building, please note that the difference in temperature greatly
changes the length measured in the building.
If a difference of 5mm or over is the result from the comparative measurement, the following procedure
as shown below could be used to change the instrument constant.
1) Provide point C on a straight line, connecting straight line AB which is almost horizontal and about
100m long, and measure straight lines AB, AC and BC.
B
A
C
2) Obtain the instrument constant by repeating 1) above several times.
Instrument constant=AC+BC-AB
3) When there is error between written instrument constant value and calculated value, review the
Section 9.7 “How to Set the Instrument Constant Value” procedure.
4) Once again, measure at a calibrated baseline and compare with the instrument base line the
length.
5) If using above procedure and no difference is found from the instrument constant at the factory or a
difference of over 5mm is found, contact TOPCON or your TOPCON dealer.
9.1.1 Checking of the accuracy of the non-prism mode
If you reset the instrument constant, you must check the accuracy of the non-prism mode.
1) Set a prism 30 to 50 meter apart from the instrument and measure the distance to the prism by
prism mode.
2) Take off the prism and set a (white) board.
3) Change the mode to the non-prism mode and measure the distance to the board.
4) Repeat above procedure and measure some points.
If the difference of the prism mode and non-prism mode is the range of ±10mm even one time, the
instrument is normal.
If the difference is never the range of ±10mm, contact TOPCON or your TOPCON dealer.
9-1
9 CHECK AND ADJUSTMENT
9.2 Checking the Optical Axis
To check if the optical axis of EDM and theodolite are matched, follow the procedure below. It is
especially important to check after adjustment of the eyepiece reticle is carried out.
1) Position a prism about more than 150 m apart from GPT-8000A/8000 series.
2) After the power switch ON of GPT-8000A/8000 series, collimate the center of the prism.
3) Press the soft key (Set audio) in the star key mode.
Buzzer sounds continuously.
H direction confirmation (Do not move V direction).
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
4) Turn the horizontal jog counterclockwise slowly, move the collimating point to the left side of prism
gradually until buzzer sound stops.
5) Turn the horizontal jog clockwise slowly, and move the collimating point to the prism center
gradually until at the position buzzer starts.
Prism
Reticle
Confirm the level of the signal (light quantity level) in display to adjust at the level of one to two as
shown in below by turning the horizontal jog.
Quantity level one
Quantity level two
6) Press the [ESC] key and measure the horizontal angle, and note the horizontal angle displayed. Or
you can do 0-set of horizontal angle.
7) Return to the Set Audio in star key again.
8) Turn the horizontal jog clockwise, move the collimating point to the right side of prism gradually until
buzzer sound stops.
9) Move the collimating point to the center of prism gradually until buzzer sound starts.
Turning the horizontal jog to be one to two level of SIG value to adjust the collimating point same as
5) procedure.
10) Note horizontal angle same as 6) procedure.
9-2
9 CHECK AND ADJUSTMENT
11) Calculate the average value of 6) and 10).
[Example]
6) •••••••••••• 0° 00’ 00”
10) •••••••••••• 0° 08’ 20”
___________________________
Average value
0° 04’ 10”
12) Climate to the center of prism. Compare the reading horizontal angle value and calculated value in
11). If the difference is within 1’30”, no problem for use.
Vertical direction confirmation (Do not move Horizontal direction).
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
13) Carry out as Horizontal direction confirmation.
Compare the reading Vertical angle value and calculated value.
If the difference is within 1’ 30”, no problem for use. If the difference is more than mentioned value,
contact with your Topcon dealer or Topcon.
[Example]
90°12’ 30”
90° 04’ 30”
Average
90°08’ 30”
Reading to
prism center
90°08’ 50”
Difference 20”
9-3
9 CHECK AND ADJUSTMENT
9.3 Checking/Adjusting the Theodolite Functions
● Pointers on the Adjustment
1) Adjust the eyepiece of the telescope properly prior to any checking operation which involves
sighting through the telescope.
Remember to focus properly, with parallax completely eliminated.
2) Carry out the adjustments in the order of item numbers, as the adjustments are dependent one
upon another. Adjustments carried out in the wrong sequence may even nullify previous
adjustment.
3) Always conclude adjustments by tightening the adjustment screws securely (but do not tighten them
more than necessary, as you may strip the threads, twist off the screw or place undue stress on the
parts).
Furthermore, always tighten by revolving in the direction of tightening tension.
4) The attachment screws must also be tightened sufficiently, upon completion of adjustments.
5) Always repeat checking operations after adjustments are made, in order to confirm results.
● Notes on the Tribrach
Note that the angle measuring precision may be effected directly if the tribrach has not been installed
firmly.
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
1) If there is any slack between the leveling screws and the base, loosen the set screw of the holding
ring and tighten the holding ring with adjusting pin, until it is properly adjusted. Re-tighten the set
screw on completing the adjustment.
Leveling screw
Holding ring
Set screw
9-4
9 CHECK AND ADJUSTMENT
9.3.1 Checking /Adjusting the Plate Level
Adjustment is required if the axis of the plate level is not perpendicular to the vertical axis.
● Check
1) Place the plate level parallel to a line running through the centers of two leveling screws, say, A and
B. Use these two leveling screws only and place the bubble in the center of the plate level.
2) Rotate the instrument 180° or 200g around the vertical axis and check bubble movement of the
plate level. If the bubble has been displaced, then proceed with the following adjustment.
Plate level
Leveling screw B
Leveling screw A
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
● Adjustment
1) Adjust the level adjustment capstan screw, with the accessory adjusting pin and return the bubble
towards the center of the plate level. Correct only one-half of the displacement by this method.
2) Correct the remaining amount of the bubble displacement with the leveling screws.
3) Rotate the instrument 180° or 200g around the vertical axis once more and check bubble
movement. If the bubble is still displaced, then repeat the adjustment.
Level adjustment
capstan screw
Half amount of displacement
9.3.2 Checking /Adjusting the Circular Level
Adjustment is required if the axis of the circular level is also not perpendicular to the vertical axis.
● Check
1) Carefully level the instrument with the plate level only. If the bubble of the circular level is centered
properly, adjustment is not required. Otherwise, proceed with the following adjustment.
● Adjustment
1) Shift the bubble to the center of the circular level, by adjusting three capstan adjustment screws on
the bottom surface of the circular level, with the accessory adjusting pin.
Capstan adjustment
screws
Bottom of the base
9-5
9 CHECK AND ADJUSTMENT
9.3.3 Adjustment of the Vertical Cross-hair
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
Adjustment is required if the vertical cross-hair is not in a place perpendicular to the horizontal axis of
the telescope (since it must be possible to use any point on the hair for measuring horizontal angles or
vertically running lines).
● Check
1) Set the instrument on the tripod and carefully level it.
2) Sight the cross-hairs on a well defined Point A at a distance of, at least, 50 meters (160ft.).
3) Next swing the telescope vertically using the jog/shuttle, and check whether the point travels along
the length of the vertical cross-hair.
4) If the point appears to move continuously on the hair, the vertical cross-hair lies in a plane
perpendicular to the horizontal axis (and adjustment is not required).
5) However, if the point appears to be displaced from the vertical cross-hair, as the telescope is swung
vertically, adjustment is required in the reticle plate.
● Adjustment
1) Unscrew the cross-hair adjustment section cover, by revolving it in the counterclockwise direction,
and take it off. This will expose four eyepiece section attachment screws.
Eyepiece section
attachment screws
Eyepiece section
attachment screws
Eyepiece
2) Loosen all four attachment screws slightly with the accessory screw-drive (while taking note of the
number of revolutions).
Then revolve the eyepiece section so that the vertical cross-hair coincides to Point A’.
Finally, re-tighten the four screws by the amount that they were loosened.
3) Check once more and if the point travels the entire length of the vertical cross-hair, further
adjustment is not required.
Note: Perform following adjustment after completing the above adjustment.
Section 9.3.4 “Collimation of the Instrument” , Section 9.4 “Adjustment of Compensation
Systematic Error of Instrument” and Section 9.8 “Inspection and Adjustment of Optic Axis for
Auto -Tracking (GPT-8000A Series)” .
9-6
9 CHECK AND ADJUSTMENT
9.3.4 Collimation of the Instrument
Collimation is required to make the line of sight of the telescope perpendicular to the horizontal axis of
the instrument, otherwise, it will not be possible to extend a straight line by direct means.
● Check
Eyepiece
1) Set the instrument up with clear
sights of about 50 to 60meters
(160 to 200 ft.) on both sides of the
instrument.
2) Level the instrument properly with the
plate level.
3) Sight Point A at approximately 50
meters (160 ft.) distance.
Telescope
4) Rotate the telescope 180° or 200g
around the horizontal axis, so that the
telescope is pointed in the opposite
direction.
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
5) Sight Point B, at equal distance as
Point A.
6) Rotate the instrument 180° or 200g
around the vertical axis. Fix a sight
on Point A once more.
7) Rotate the telescope 180°
or 200g around the horizontal axis
once more and fix a sight on Point C,
which should coincide with previous
Point B.
8) If Points B and C do not coincide,
adjust in the following manner.
● Adjustment
1) Unscrew the cross-hair adjustment section cover.
2) Find Point D at a point between Points C and B, which should
be equal to 1/4th the distance between Points B and C and
measured from Point C. This is because the apparent error
between Points B and C is four times the actual error since
the telescope has been reversed twice during the checking
operation.
3) Shift the vertical cross-hair line and coincide it with
Point D, by revolving the left and right capstan
adjustment screws with the adjusting pin.Upon
completing the adjustment, repeat the checking
operation once more.
If Points B and C coincide, further adjustment is not
required. Otherwise, repeat the adjustment.
Capstan
adjustment
screws
Capstan
adjustment
screws
9-7
Eyepiece
9 CHECK AND ADJUSTMENT
Note: 1
2
First, loosen the capstan adjustment screw on the side to which the vertical cross-hair
line must be moved. Then tighten the adjustment screw on the opposite side by an equal
amount which will leave the tension of the adjustment screws unchanged.
Revolve in the counterclockwise direction to loosen and in the clockwise direction to
tighten, but revolve as little as possible.
Perform following adjustment after complete above adjustment. Section 9.4 “Adjustment
of Compensation Systematic Error of Instrument” , Section 9.2 “Checking the Optical
Axis” and Section 9.8 “Inspection and Adjustment of Optic Axis for Auto -Tracking (GPT8000A Series)” .
9.3.5 Checking / Adjusting the Optical Plummet Telescope
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
Adjustment is required to make the line of sight of the optical plummet telescope coincide with the
vertical axis (otherwise the vertical axis will not be in the true vertical above the reference point when
the instrument is optically plumbed).
● Check
1) Coincide the center mark and the point. (See Chapter 2 “PREPARATION FOR MEASUREMENT”.)
2) Rotate the instrument 180° or 200g around the vertical axis and check the center mark.
If the point is properly centered in the center mark, adjustment is not required. Otherwise, adjust in
the following manner.
● Adjustment
1) Take off the adjustment section cover of the optical plummet telescope eyepiece. This will expose
four capstan adjustment screws which should be adjusted with the accessory adjusting pin to shift
the center mark to the point. However, correct only one-half of the displacement in this manner.
Capstan
adjustment
screws
Capstan
adjustment
screws
1/2 of displacement
Eyepiece
Plummet telescope
2) Use the leveling screws and coincide the point and center mark.
3) Rotate the instrument 180° or 200g around the vertical axis once more and check the center mark.
If it is coincided to the point, then further adjustment is not required. Otherwise, repeat the
adjustment.
Note: First, loosen the capstan adjustment screw on the side to which the center mark must be
moved. Then tighten the adjustment screw on the opposite side by an equal amount which
will leave the tension of the adjustment screws unchanged.
Revolve in the counterclockwise direction to loosen and in the clockwise direction to tighten,
but revolve as little as possible.
9-8
9 CHECK AND ADJUSTMENT
9.3.6 Checking / Adjusting the Laser Plummet (For Laser Plummet type)
● Check
1) Turn on the laser plummet and coincide the center of the laser with a measuring point.
2) Rotate the instrument 180° or 200g around the vertical axis and check the measuring point.
If the laser is properly centered in the measuring point, adjustment is not required. Otherwise,
adjust in the following manner.
● Adjustment
1) Turn the adjustment screws with the
accessory hexagonal wrench to shift the
laser to the measuring point. However,
correct only one-half of the displacement in
this manner.
Adjustment
screws part is
located
Laser
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
1/2 of displacement
Adjustment screws
(4 pcs)
Measuring
point
2) Use the leveling screws and coincide the center of the laser and the point.
3) Rotate the instrument 180° or 200g around the vertical axis once more and check the point and the
laser. If the laser is coincided to the measuring point, then further adjustment is not required.
Otherwise, repeat the adjustment.
Note: First, loosen the adjustment screw to move the laser. Then tighten the adjustment screw on the
opposite side by an equal amount which will leave the tension of the adjustment screws
unchanged.
Revolve in the counterclockwise direction to loosen and in the clockwise direction to tighten, but
revolve as little as possible.
Reference
The laser can be moved by turning the adjustment screws clockwise as follows.
Laser beam
Laser is moved lower right.
Laser is moved
lower left.
Laser is moved upper left.
Laser is moved
upper right.
Top of view of the measuring point
Adjustment screws
9-9
9 CHECK AND ADJUSTMENT
9.4 Adjustment of Compensation Systematic Error of Instrument
1) Error of vertical axis (X,Y tilt sensor offset)
2) Collimation error
3) Error of vertical angle 0 datum
4) Error of horizontal axis
The above mentioned errors will be compensated by software, which calculated internally according to
each compensation value.
Also these errors can be compensated by software collimating one side of the telescope that is carried
out to delete the error by turning in normal and reverse both sides of telescope so far.
Operating procedure
Operation
Display
1 Level the instrument properly with the plate
level.
2 Press [F5] key from the main menu.
[F5]
3 Press [F1] key .
[F1]
Adjustment
F1 V0/Axis (Measurement)
F2 V0/Axis (Constant list)
F3 Date Time
F4 Instrument constant
↓
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
[V0/Axis Adjustments]
ERROR CORRECTION
(A) Tilt,V0 init,Collimation
(B) H Axis
4 Collimate target A (around 0° in horizontal
within ±3°) in normal telescope setting
(FACE(1)).
Collimate
A
(Normal)
(A)COLLIMATION
FACE 1
/0
LEVEL±0
V: 88°40'20"
SKIP
5 Press [F6](SET)key. *1)
FACE 1
[F6]
The sample display shows that the
measurement is made 5 times in FACE 1.
SET
/5
LEVEL±0
V: 89°55'50"
SKIP
6 Turn the telescope in reverse telescope
setting (FACE(2)).
Turn
telescope
SET
FACE 2
LEVEL±0
0/5
V:270°04'20"
SKIP
9-10
SET
9 CHECK AND ADJUSTMENT
7 Collimate target A.
Collimate
A
(Reverse)
8 Press [F6](SET)key.
[F6]
Repeat the procedures in step 7 and 8 so
that the count of measured times matches to
the one in FACE(1).
* 2),3),4)
FACE 2
5/5
LEVEL±0
V:270°04'20"
SKIP
SET
The title display will be shown automatically.
(B)HORIZONTAL Axis
e
FACE 2
/0
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
LEVEL±10°
V:270°04'20"
SKIP
9 Collimate target B (more than ±10° from the
level ) in reverse telescope setting (FACE(2)).
*5)
SET
Collimate
B
(Reverse)
10 Press [F6](SET)key. *1)
FACE 2
[F6]
/5
LEVEL±10°
V:270°04'20"
SKIP
11 Turn the telescope in normal telescope
setting(FACE(1)).
Turn
telescope
SET
FACE 1
LEVEL±10°
5/5
V: 69°58'30"
SKIP
12 Collimate target B.
SET
Collimate
B
(Normal)
13 Press [F6](SET) key. Repeat the procedures
in step 12 and 13 so that the count of
[F6]
measured times matches to the one in
FACE(2).
Then the display returns to main menu.
Complete
*1) It is able to get the average value from 1 to 10 measurements.To get the average, repeat the
procedures in steps 4, 5 or 9 , 10. The measured times is counted in the second line of display.
*2) The compensation values of 1) Error of vertical axis (X,Y tilt sensor offset),
2) Collimation error, and 3) Error of vertical angle 0 datum will be set and memorized internally.
*3) The operating procedure steps to set compensation value of 4) Error of horizontal axis.
*4) Pressing [F1](SKIP) key enables to set next step without changing the last compensated value.
*5) Pressing [F1](SKIP) key makes end of setting without changing compensation value.
9-11
9 CHECK AND ADJUSTMENT
9.5 Showing Constant List and Switch ON/OFF
Compensation Systematic Error of Instrument
[Example setting: Switch OFF the compensation]
Operating procedure
Operation
Display
1 Press [F5] key from the main menu.
[F5]
Adjustment
F1 V0/Axis (Measurement)
F2 V0/Axis (Constant list)
F3 Date Time
F4 Instrument constant
↓
2 Press [F2] key .
[F2]
Vco:
Hco:
HAx:
Correction values are displayed.
-1°57'12"
-0°00'20"
-0°00'20"
EXIT
3 Press [F6](OFF) key.
Vco:
Hco:
HAx:
OFF
ON
OFF
-1°57'12"
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
[F6]
ON
EXIT
4 Press [F1](EXIT) key.
[F1]
The display returns to main menu.
9-12
9 CHECK AND ADJUSTMENT
9.6
How to adjust the date and time
Operating procedure
Operation
1 Press [F5] key from the main menu.
[F5]
2 Press [F3] key.
[F3]
Current date will be on the display.
Display
Adjustment
F1 V0/Axis (Measurement)
F2 V0/Axis (Constant list)
F3 Date Time
F4 Instrument constant
↓
Current date is 01-25-02
Enter new date (mm-dd-yy)
Modify
YES
3 Press [F5] (YES) key.
[F5]
The cursor will blink on the first digit to type in
a numeric value.
Current date is 01-25-02
Enter new date (mm-dd-yy)
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
EXIT
4 Input new date and press [ENT] key.
[Example:07-29-02]
NO
[0][7]
[2][9]
[0][2]
[ENT]
5 Press [F5] (YES) key.
BS
Current time is 14:55:28
Enter new time (hh-mm-ss)
Modify
YES
NO
[F5]
Current time is 14:55:28
Enter new time (hh-mm-ss)
EXIT
6 Input new time and press [ENT] key.
[Example:13:20:50]
The display returns to main menu.
BS
[1][3]
[2][0]
[5][0]
[ENT]
● The [F6](BS) key is for moving the cursor to the left one digit at a time for editing.(If you do not want to
change the date, press the [F1](EXIT) key or [ESC] key to get to the time display.
● Enables you to change the order of date, see Chapter 8 “PARAMETERS SETTING MODE” .
9-13
9 CHECK AND ADJUSTMENT
9.7 How to Set the Instrument Constant Value
To set the Instrument constant which is obtained in section 9.1 “Checking and Adjusting of Instrument
Constant”, follow as below.
Note: Each of the Prism mode and Non-prism mode has instrument constant.
You must obtain the instrument constant of prism mode. If you reset the instrument
constant of the prism mode, you must vary the non-prism constant (Non-prism-short, Nonprism-long) by the same quantity as the amount of increase or decrease of the instrument
constant of the prism mode.
Operating procedure
Operation
Display
[F5]
Adjustment
F1 V0/Axis (Measurement)
F2 V0/Axis (Constant list)
F3 Date Time
F4 Instrument constant
↓
2 Press [F4] (Instrument constant) key.
[F4]
Instrument Constant
F1 PRISM
F2 NON-PRISM-SHORT
F3 NON-PRISM-LONG
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
1 Press the [F5] key from the main menu.
3 Select constant value.
[F1]
Example: Prism
4 Press [F5] (YES) key .
5 Input value and press [ENT] key. *1),2)
[F5]
Instrument Constant
EDM OFFSET (mm)
0.0
Modify
YES
NO
Instrument Constant
EDM OFFSET (mm)
0.0
This is not Prism Offset!
EXIT
BS
Input
value
[ENT]
Instrument Constant
EDM OFFSET (mm)
1.2
The old value will be erased!
OK CANCEL
6 Press [F5](OK) key.
[F5]
Complete
The display returns to main menu.
*1) Refer to Section 2.9 “How to Enter Numerals and Alphabet Letters” .
*2) To cancel the setting, press the [ESC] key.
9-14
9 CHECK AND ADJUSTMENT
9.8
Inspection and Adjustment of Optic Axis for Auto -Tracking
(GPT-8000A Series)
Activates auto tracking to the prism.
Confirm if the center of telescope reticle and the center of the prism is coincided.
Any error between them requires adjustment according to the following procedure.
Prism center
Telescope reticle center
Prism center
Telescope reticle center
Centers of prism
and telescope is shifted
Normal position
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
● Position a prism around 0 in horizontal and about 50m to 100m (164 to 328ft) apart from the GPT8000A series.
● Take care not to be interrupted the optical path during measurement.
Operating procedure
Operation
1 Level the instrument properly with the plate
level and press the [F5] key from main menu.
2 Press the [F6] key to get the next page.
3 Press the [F1] key to select the adjustment of
[F5]
Adjustment
F1 V0/Axis (Measurement)
F2 V0/Axis (Constant list)
F3 Date Time
F4 Instrument constant
↓
[F6]
Adjustment
F1 Adj Tracking Axis
[F1]
tracking axis.
Display
↑
Adj Tracking Axis
[1/2]
>Sight the prism !!
TURN
4 Operate H / V jog shuttle to collimate the
prism
MEAS
Collimate
5 Press the [F6](MEAS) key.
[F6]
The measurement starts.
Adj Tracking Axis
Wait
6 After the measurement, press the [F1](TURN)
[F1]
key.
The instrument and telescope will turn
automatically.
7 Operate H / V jog shuttle to collimate the
prism
Adj Tracking Axis
[2/2]
>Sight the prism !!
TURN
Collimate
9-15
MEAS
9 CHECK AND ADJUSTMENT
8 Press the [F6](MEAS) key.
[F6]
The measurement starts.
Adj Tracking Axis
Wait
The shifted quantity between H angle and V
angle measured from the measuring will be
calculated internally.
Adj Tracking Axis
>Set OK?
YES
9 Press the [F5](YES) key.
NO
[F5]
The compensation value will be set and
memorized to GPT-8000A series.
The display will return to the main menu.
Complete
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
● The display shows “Compensation Range Overcoat” when the calculated compensation value is
exceeded than limited value.
● If the distance between the instrument and the prism is not enough to adjust, the display shows “The
distance is too short”. The distance between the instrument and prism should be more than 35m.
● If the difference of the measured data between in normal position and in inverted position is exceeded
than limited value, the display shows “Tolerance Limit Over”.
● If the measuring is unstable when the atmospheric condition is bad or the optical path is interrupted,
the display shows “Standard Deviation Over”.
● To cancel the compensation, press the [F6](NO) key.
9-16
10 SETTING THE PRISM / NON-PRISM CONSTANT VALUE
10
SETTING THE PRISM / NON-PRISM CONSTANT
VALUE
The prism constant value of Topcon is set to zero. When using prism other than Topcon's, it is
necessary to set the prism constant correction value of that specific prism.
Once you set the correction value for prism constant, it is retained after power is OFF.
Note: Confirm the non-prism constant value is set at 0 when measuring target such as walls in
Non-prism mode.
● Setting the prism constant value is in the STAR key mode.
● Setting example : The prism constant value : -14mm
Operating procedure
Operation
1 Press STAR (
) key.
GPT-8000A series should be changed the
menu of star key mode to page three by
pressing the [F6] key twice.
[
Display
]
2002-08-10 14:30:40
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
NP/P 1↓
2 Press the [F3](GPT-8000 series) or [F2](GPT-
[F3]
or
[F2]
8000A series) key.
Current setting value is displayed.
GPT-8000 series
2002-08-10 14:30:40
3↓
GPT-8000A series
Prism constant correction icon
20.0 °C
1012.0hPa
5.1ppm
0.0 mm
23.6 mm
Non-Prism constant correction icon
3 Move the cursor (>) to psm setting by
Move
cursor
pressing [F5]((→, ←) key or [F6](↓,↑) key.
4 Input the Prism constant correction value and
Enter
value
press the [ENT] key.
*1)
[ENT]
The display returns STAR key menu.
*1) Input range : -99.9mm to +99.9mm, 0.1mm step
10-1
20.0 °C
1012.0hPa
5.1ppm
+14.0 mm
23.6 mm
11 SETTING ATMOSPHERIC CORRECTION
11
SETTING ATMOSPHERIC CORRECTION
The velocity of light through air is not constant and depends on the atmospheric temperature and
pressure. The atmospheric correction system of this instrument corrects automatically when the
correction value is set. 15°C/59°F, and 1013.25hPa / 760mmHg / 29.9 inHg is as a standard value for
0ppm in this instrument. The values are kept in the memory even after power is OFF.
● Setting the atmospheric correction value is in the STAR key (
) mode.
11.1 Calculation of Atmospheric Correction
The followings are the correction formulas.
Unit; meter
Ka: Atmospheric correction value
P : Ambient atmospheric pressure (hPa)
t : Ambient Atmospheric temperature (°C)

–6
×P 
Ka =  279.85 – 79.585
--------------------------  × 10
273.15 + t 

The distance L (m) after atmospheric correction is obtained as follow.
L = l (1+Ka)
l :Measured distance when atmospheric
correction is not set.
Example : In case Temperature +20°C, Air pressure 847hPa, l =1000 m
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e

–6
× 847 
Ka =  279.85 – 79.585
-------------------------------  × 10

273.15 + 20 
+ 50×10-6 (50 ppm)
L = 1000 (1+50×10-6) = 1000.050 m
11.2 Setting of Atmospheric Correction Value
● How to Set Temperature and Pressure Value Directly
Measure the temperature and air pressure surrounding the instrument beforehand.
Example : Temperature: +26°C, Pressure:1020 hPa
Operating procedure
1 Press STAR (
) key.
GPT-8000A series should be changed the
menu of star key mode to page three by
pressing the [F6] key twice.
Operation
[
]
Display
2002-08-10 14:30:40
NP/P 1↓
GPT-8000 series
2002-08-10 14:30:40
3↓
GPT-8000A series
2 Press the [F3](GPT-8000 series) or [F2](GPT-
[F3]
or
[F2]
8000A series) key.
Current setting value is displayed.
3 Input Temp.value and press [ENT] key.
[Example] Temp. : +26°C
The cursor moves to Pressure setting
automatically
Enter
value
[ENT]
11-1
Temperature setting
20.0 °C
1012.0hPa
5.1ppm
+14.0 mm
23.6 mm
Pressure setting
26.0 °C
1012.0hPa
5.1ppm
+14.0 mm
23.6 mm
11 SETTING ATMOSPHERIC CORRECTION
4 Input Pressure value, and press [ENT].
Enter
value
[Example] Pres. :1020.0hPa.
The display returns previous mode.
*1) *2)
[ENT]
26.0 °C
1020.0hPa
5.1ppm
+14.0 mm
23.6 mm
The display returns STAR key menu.
-30.0 °C to +60.0 °C (0.1 °C step)
560.0 to1066.0hPa (0.1hPa step) , 420.0 to 800.0mmHg (0.1mmHg step)
16.5 to 31.5inHg (0.1inHg step)
*2) When the atmospheric correction value, which is calculated from the input temperature and pressure
values, exceeds the range ± 999.9ppm, the operating procedure returns to step 3 automatically. Input
values again.
*1) Range : Temp.
Pres.
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
● How to Set the Atmospheric Correction Value Directly
Measure the temperature and air pressure to find atmospheric correction value (PPM) from the chart or
correction formula.
[Example] Atmospheric correction value
Operating procedure
Operation
1 Press STAR (
) key.
GPT-8000A series should be changed the
menu of star key mode to page three by
pressing the [F6] key twice.
[
2 Press the [F3](GPT-8000 series) or [F2](GPT-
]
[F3]
or
[F2]
8000A series) key.
Current setting value is displayed.
Display
2002-08-10 14:30:40
NP/P 1↓
GPT-8000 series
2002-08-10 14:30:40
3↓
GPT-8000A series
20.0 °C
1012.0hPa
5.1ppm
0.0 mm
23.6 mm
PPM setting
3 Move the cursor (>) to PPM setting by
Move
cursor
pressing [F5](→) key.
0.0 mm
23.6 mm
5.1ppm
4 Enter atmospheric correction value and press
Enter
PPM
[ENT]
[ENT] key. *1)
The display returns previous mode.
*1) Input range : -999.9mm ~ +999.9mm, 0.1mm step
11-2
11 SETTING ATMOSPHERIC CORRECTION
Atmospheric Correction Chart (For your reference)
The atmospheric correction value is obtained easily with the atmospheric correction chart. Find the
measured temperature in horizontal, and pressure in vertical on the chart.
Read the value from the diagonal line, which represents the required atmospheric correction value.
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
Example:
The measured temperature is +26°C
The measured pressure is 1013 hPa
Therefore,
The correction value is +10ppm
11-3
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
11 SETTING ATMOSPHERIC CORRECTION
11-4
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
11 SETTING ATMOSPHERIC CORRECTION
11-5
12 CORRECTION FOR REFRACTION AND EARTH CURVATURE
12
CORRECTION FOR REFRACTION AND EARTH
CURVATURE
The instrument measures distance, taking into account correction for refraction and earth curvature.
Note: If the telescope is positioned within ±9° from the nadir or zenith, no measurement will result
even if the correction function for refraction and earth curvature works.
The display shows “W/C OVER”.
12.1 Distance Calculation Formula
Distance Calculation Formula; with correction for refraction and earth curvature taken into account.
Follow the Formula below for converting horizontal and vertical distances.
e
Horizontal distance D = AC(α) or BE(β)
Vertical distance Z =BC(α) or EA(β)
D = L{cosα–(2θ – γ ) sinα}
Z = L{sinα+(θ – γ ) cosα}
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
θ = L.cosα/2R........... Earth curvature
correcting item
γ =K•Lcosα/2R.......
Atmospheric
refraction
correcting item
K =0.14 or 0.2.......... Coefficient of
refraction
R =6372km.............. Radius of earth
α ( or β)................... Altitude angle
L .............................. Slope distance
● The conversion formula for horizontal and vertical distances is as follows when correction for
refraction and earth curvature is not applied.
D=L•cosα
Z=L•sinα
Note: The coefficient of the instrument has been set at 0.14 before shipment (K=0.14).
if the "K" value is to be changed, refer to 8 “ PARAMETERS SETTING MODE”.
12-1
13 POWER SOURCE AND CHARGING
13
POWER SOURCE AND CHARGING
13.1 Rechargeable Battery BT-56Q
● To remove
Remove the battery while pulling both battery fixing levers.
BC-27BR/CR
BT-56Q
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
Battery fixing
lever
e
AC-outlet
● To charge
1 Plug the charger into the outlet.
2 Connect the charger connector to the battery, then charging will start.
Preparatory charging will start.* (The red lamp of the charger will blink.)
When the preparatory charging is completed, the charging status will be switched to quick charging
automatically. (The red lamp of the charger will light.)
3 Charging will take approximately 2.5 hours. (The green lamp will illuminate.)
4 After charging, remove the battery from the charger.
Remove the charger from the outlet.
● To refresh
Press the refresh switch after starting charging above steps (1, 2 ), then discharging will start. Confirm
the yellow lamp illuminates.
After discharging is finished , charging will start automatically.
Time discharging battery charged fully is approximately 12 hours.
● For refreshing
Rechargeable battery can be used repeatedly by charging. If charging is repeated by the state that
capacity of the battery still left, operating time of the battery may shorten. In this case, the voltage of the
battery will be recovered by refreshing and operating time can be improved.
*About Preparatory charging
Before quick charging, the battery is charged using small amount current to measure its temperature
and voltage.
When the temperature and voltage is within a range, the charging status will change to quick charging.
The lamp of charger
Red blinking : Preparatory charging
Red ON
: Charging
Red lamp will illuminate during charging.
Green ON
: Charging completed
Green lamp will illuminate after completely charging.
Yellow ON
: Discharging
Yellow lamp will illuminate and discharging will start by pressing the refresh
(discharge) switch.
Red quick flashing : Abnormal outbreaks
Red lamp will flash when the battery life is over or the battery is broken down.
Replace the battery to new one.
● To install
1 Place the battery to the instrument.
2 Gentry push the battery and clicks into position.
13-1
13 POWER SOURCE AND CHARGING
● Do not charge or discharge continuously, otherwise the battery and the charger may be
deteriorated. If charging or discharging is necessary, use the charger after stopping charge for
approximately 30 minutes.
● Do not charge the battery or discharge the battery in right after the battery is charged, it causes
deterioration of the battery in rare cases.
● The charger may develop heat while charging, there is no problem of it.
4
5
6
e
2
3
Recharging should take place in a room with an ambient temperature range of 10°C to
40°C (50°F to 104°F).
If charging is done at high temperature, charging time of the battery may take longer.
Exceeding the specified charging time may shorten the life of the battery and should be
avoided if possible.
The battery source will discharge when stored and should be checked before using with
instrument .
Be sure to charge as stored battery source every 3 or 4 months and store in a place at
30°C and below when it will not used for a long period.
If you allow the battery to be completely discharged, it will have an effect on the overall
performance for proper charging in the future.
Keep batteries charged at all times.
For further information, see APPENDIX 2 “Precaution when Charging or Storing Batteries”.
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
Note: 1
13-2
14 DETACH/ATTACH OF TRIBRACH
14
DETACH/ATTACH OF TRIBRACH
The instrument is easily detached or attached to the tribrach.
Tribrach fixing screw
Securing screw
Tribrach alignment groove
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
Tribrach fixing lever
Alignment piece
Tribrach alignment groove
●
1)
2)
3)
Detachment
Loosen the tribrach fixing screw.
Loosen the tribrach fixing lever by turning counterclockwise.
Lift the instrument straight upwards and off.
● Attachment
1) Coincide the white alignment piece on the lower part of the instrument with the tribrach alignment
groove.
2) Tighten the tribrach fixing lever firmly by turning clockwise.
3) Tighten the tribrach fixing screw.
● Locking the Tribrach Fixing lever
The tribrach fixing lever can be locked from being moved accidentally. This is useful if the upper
instrument section is not being detached very often. Simply tighten the securing screw on the fixing
lever with the accessory screw driver.
14-1
15 BATTERY SYSTEM
15
BATTERY SYSTEM
In case of Rechargeable Battery BT-56Q
In case of External battery Pack
BT-3Q
BT-3L
PC-5
PC-6
BT-56Q
GPT-8000A/8000 series
PC-5 or PC-6
AC-6
GPT-8000A/8000 series
External 12V battery
Charging
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
Charging time
BC-27BR/CR
Approx. 2.5h
BT-56Q
Approx.15h
BC-10C
BC-10B
Quick
BC-27BR for AC 120V use
BC-27CR for AC 230V use
Normal
BC-10B for AC 120V use
BC-10C for AC 230V use
Approx.1h
BT-3Q
BC-5
Quick
for AC 100V / 120V / 220V
/ 240V use
Approx.2h
BC-9
Approx.15h
BC-6
BT-3L
15-1
Quick
for DC 13.8 to 16V use
Normal
for AC 100V / 120V / 220V
/ 240V use
16 PRISM SYSTEM
16
PRISM SYSTEM
Arrangement according to your needs is possible.
Target pole-2
(not used with 9 prisms)
Prism-2
Tilting prism Single prism
holder-3
holder-2
Tilting triple
prism holder-1
Triple prism
holder-2
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
Tilting prism
holder-2
with target
plate-2
9 prism
holder-2
Pole adaptor- A
Plug3
Tribrach
adaptor-S2
Tribrach
adaptor-2
Tribrach
Pole adaptor- F2
Optical plummet tribrach
It is possible to change the combination
according purpose.
Fixed 9 prisms unit
Tilt single prism unit
Prism unit A3/A3S
Fixed 3 prisms unit
Tripod
Use the above prisms after setting them at the same height as the instruments. To adjust the height of
prism set, change the position of fixing screws.
Plug 3 is necessary for the tribrach adaptor-2, tribrach adaptor-S2 and pole adaptor-F2 to coincide with
the height of GPT-8000A/GPT-8000 series.
16-1
17 PRECAUTIONS
PRECAUTIONS
1) For transportation, hold by the handle or yoke of the instrument. Never hold by the lens barrel as it
can affect the fixing bracket inside and reduce the accuracy of the instrument.
2) Never expose the instrument without a filter to direct sunlight. It may damage the components
inside the instrument.
3) Never leave the instrument unprotected in high temperature. The temperature inside instrument
may easily reach up to 70°C or above and will reduce the service life.
4) When a high degree of precision is required for measurement, provide shade against direct sunlight
for the instrument and tripod.
5) Any sudden change of temperature to the instrument or prism may result in a reduction of
measuring distance range, i.e. when taking the instrument out from a heated vehicle.
6) When opening the carrying case and taking out the instrument, place the case horizontally, then
open the case.
e
7) When returning the instrument to its case, be sure to match the white positioning marks provided
with the case and place the instrument with the eyepiece upward.
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
17
8) For transportation, provide dampening or a cushion appropriately to avoid sudden shock or
vibration.
9) For cleaning the instrument after use, remove dust using a cleaning brush, then wipe off with a
cloth.
10) For cleaning the lens surface, use a cleaning brush to remove the dust, then use a clean lintless
cotton cloth. Moisten it with alcohol (or mixture with ether) to wipe gently in a rotational motion from
the center out.
11) Even if any abnormality occurs, never attempt to disassemble or lubricate the instrument yourself.
Always consult with TOPCON or your dealer.
12) To remove the dust on the case, never use thinner or benzine. Use a clean cloth moistened with
neutral detergent.
13) Check each part of the tripod after extended use. Parts (screws or clamps) may work themselves
free.
17-1
18 ERROR DISPLAYS
18
ERROR DISPLAYS
Error code
Description
Countermeasures
Backup
battery
empty
Displayed when built in battery for memory
back up is empty.
Contact your dealer or Topcon.
W/C OVER
Displayed when measurement carried out
within ±9° from zenith or nadir at the Earth
curvature and refraction correction mode is
ON.
Set correction for refraction and earth
curvature mode OFF or measure out of ±9 °
from the zenith or Nadir.
H angle
measuring
error
Displayed when the instrument rotated too
fast or any abnormality occurs in angle
measuring system .
The instrument will return to previous mode
automatically.
V angle
measuring
error
Displayed when the telescope rotated too fast
The instrument will return to previous mode
or any abnormality occurs in angle measuring
automatically.
system.
E31
Displayed when the unit of the angle at the
recall mode is different from the unit stored in
setting mode.
E35
Displayed when REM measurement carried
out to the range from zenith or nadir ± 6° .
Operate in the range out of ± 6° from the
zenith or nadir.
E36
Displayed when the N.E coordinates are set
same as the instrument coordinate in setting
direction angle or lay out mode.
Set except the instrument coordinate value.
E60’s
Any abnormality occurs with EDM (distance
measuring system).
Repair is required.
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
Make the unit in same unit system.
E71
Displayed when Vertical angle 0 position is set
Confirm the procedure and readjust.
with incorrect procedure.
E72
Displayed when Vertical angle -position is
adjusted in wrong position.
Confirm the procedure and readjust
E73
The instrument was not leveled when Vertical
angle 0-position is adjusted.
Level the instrument then carry the
adjustment work.
E81
E82
Mainly at the time data transmission between
the total station and external instrument.
Press [F1](EXIT) key, and confirm the
connection cables are correct.
Other
E80‘s
Data transmission error between internal
P.C.B.‘s.
Restart and confirm the operation procedure
is correct.
E90‘s
Abnormality in internal memory system.
Repair is required.
E600‘s
Abnormality in angle measuring system.
If this error code continues to display, repair is
required.
E700‘s
Abnormality in angle measuring system.
If this error code continues to display, repair is
required.
E800‘s
In the self checking mode, vibration is too big. Get rid of the Vibration
● If error still persist after attempting to clear them, contact your local Topcon dealer or Topcon head
office.
18-1
19 SPECIAL ACCESSORIES
19
SPECIAL ACCESSORIES
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
Remote Control System RC-2II
Using together with RC-2II makes it possible to optical
communication between the GPT-8000A series and
RC-2II. This gives easy operation for one man
surveying.
Tribrach TR-5
This is detachable tribrach having tribrach fixing
screw.
Optical plummet tribrach TR-5P
This is detachable tribrach having built-in optical
plummet telescope.
(Compatible with Wild)
Trough compass, Model 6
Shock proof construction. No clamp is necessary
when carrying the instrument.
Solar filter, Model 6
A filter designed exclusively for direct collimation of
the sun.
Solar filter of flap-up type.
Diagonal eyepiece, Model 10
Solar reticle, Model 6
Observation in an easy posture will be provided up to A reticle designed for collimation of the sun.
the zenith position
Can be used together with Solar Filter.
19-1
19 SPECIAL ACCESSORIES
Prism unit case, Model 3
This is the plastic case to store and carry various
sets of prisms.
The case covers one of the following prism sets:
● Tilt single prism set
● Tilt single prism set with a target plate
● Fixed triple prism unit
● Fixed triple prism unit with a target plate
Prism unit case, Model 5
● External dimensions:
1 prisms unit or fixed 3 prisms unit can be stored in
427(L)×254(W)×242(H) mm
this case. Especially, this is a very easy case to carry. ● Weight:3.1kg
Soft material is used.
● External dimensions:
200(L)×200(W)×350(H) mm
● Weight:0.5kg
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
Prism unit case, Model 6
Fixed 9 prisms unit or tilting 3 prisms unit can be
stored in this case. Especially, this is a very easy case
to carry. Soft material is used.
● External dimensions:
250(L)×120(W)×400(H) mm
● Weight:0.5kg
Gadget case, Model 1
A case to store and carry accessories.
● External dimensions:
300(L)×145(W)×220(H) mm
● Weight:1.4kg
Back pack, Model 2
Convenient for use in mountainous terrain.
Cigarette battery charger BC-9 (for BT-3Q)
● Input voltage:13.8V to 16V
● Power consumption: 40VA approx.
● Charging time:
approx. 2 hour (+20°C) to charge BT-3Q
● Operation temperature range:
+10°C to +40°C (+50 to +104°F)
● External dimensions:
116(L)×60(W)×50(H) mm
● Weight:0.3kg
Battery charger BC-6 (for BT-3L)
● Input voltage:100, 120, 220, 240V
AC: ±10% 50/60 Hz
● Power consumption: 15VA approx.
● Charging time:
approx. 15 hour (+20°C) to charge BT-3L
● Operation temperature range:
+10°C to +40°C (+50 to +104°F)
● External dimensions:
142(L) × 96(W) × 64(H) mm
● Weight:1.0kg
19-2
19 SPECIAL ACCESSORIES
Power cord PC-5
(For BT-3Q and TOPCON FC series Data collector)
● L-shape plug provided
● Cord length: 2m approx.
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
Power cord PC-6 (For BT-3L)
● L-shape plug provided
● Cord length: 2m approx.
Large capacity battery pack BT-3L
● Output voltage : DC 8.4V
● Capacity: 6AH
● External dimensions:
190(L) × 106(W) × 74(H) mm
● Weight:2.8kg
Auto Converter AC-6
● Input voltage : DC12V
● Output voltage : DC 8.4V ±5%
● Current rating : 3A
● Connection cable length : Approx. 3m
● External dimensions :
100(L) x 50(W) x 52(H) mm
● Weight : Approx. 300g
Aluminum extension leg tripod, Type E
● Flat head 5/8" × 11 threads with adjustable legs.
Wide-frame extension leg tripod, Type E (Wood)
● Flat head 5/8" × 11 threads with adjustable
legs.
Prism sets
See the description on Chapter 16 "PRISM SYSTEM"
Data card
Capacity
The number of Measurement Points
128 K bytes
Approx. 2,000 points
256 K bytes
Approx. 4,000 points
512 K bytes
Approx. 8,000 points
19-3
20 SPECIFICATIONS
SPECIFICATIONS
Telescope
Length
Objective lens
Magnification
Image
Field of view
Resolving power
Minimum focus
Focusing knob
GPT-8001A/8002A/8001/8002
GPT-8003A/8003/8005A/8005
:
:
:
:
:
:
:
166mm
50mm (EDM 50mm)
30×
Erect
1°30'
3"
1.3m
: 2 speed way
: 1 speed way
Automatic Tracking / Collimating (GPT-8000A series)
Maximum Automatic Tracking speed
: 12° /sec
Automatic Collimating area
: ±5°
Automatic Tracking range *1:
8 to 800 m (26 to 2,625ft)
Prism Unit Type A2/A3/A3S
10 to 500 m (33 to 1,640ft)
e
Prism type 2, with 1 prism
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
20
Reflector tape
Automatic Collimation / Tracking accuracy
Search pattern
Search range
Safety standard for Laser Beam
10 to 50 m (33 to 164 ft)
:
:
:
:
3” Standard deviation *2
Pattern 1 / Pattern 2
Any value can be set, able to set (1° step)
Class 2 (IEC Publication 825)
Class ll (FDA/BRH 21 CFR 1040)
*1 Condition : Normal (Visibility about 20km), except high humidity time.
*2 The air condition is stable and prism is staying.
Manual Driving
Maximum rotating speed *
Coarse movement
Fine movement
: 50° /sec
: Shuttle driving (in 7 steps)
: Jog driving (minimum step about 1 second)
*By reverse, rotating instruction
20-1
20 SPECIFICATIONS
Distance measurement
Measurement range
Non-prism mode (Target: White wall)
Atmospheric conditions
In low light condition and without
sun glare on target
3 to 120 m (9.8 to 394 ft)
Prism mode
Atmospheric conditions
Prism
Condition 1
2 to1,500m (6.6 to 4,920ft)
2 to 7,000m (6.6 to 22,900ft)
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
Prism type 2, with 1 prism
e
Mini prism
Condition 1:Sight haze with visibility about 20km (12.5miles) moderate sunlight
with light heat shimmer.
Measurement accuracy
Non-prism mode (Diffusing Surface)
3 to 25m (9.8 to 82ft)
25m or more (82ft or more)
Prism mode
Fine measurement mode
Course measurement mode
: ± (10mm) m.s.e.
: ± (5mm +2ppm × D) m.s.e.
D: Measuring distance (mm)
: ±(3mm +2ppm × D) m.s.e.
: ±(10mm +2ppm × D) m.s.e.
D: Measuring distance (mm)
Least Count in Measurement
Fine measurement mode
: 1mm (0.005ft.) / 0.2mm (0.001ft)
Coarse (1mm) measurement mode : 1mm (0.005ft.)
Coarse (10mm) measurement mode : 10mm (0.02ft.)
Measurement Display
Measurement Time
Fine measurement mode
: 10digit : max. display ±999999.9999m
Atmospheric Correction Range
Prism Constant Correction Range
Coefficient Factor
: –999.9ppm to +999.9ppm , in 0.1ppm increments
: –99.9 mm to +99.9 mm , in 0.1 mm increments
: Meter / Feet
International feet 1meter = 3.2808398501 ft.
US SURVEY feet 1meter = 3.2808333333 ft.
: –20°C to +50°C (–4°F to +122°F)
:
:
Coarse (1mm) measurement mode :
Coarse (10mm) measurement mode :
Ambient Temperature Range
1mm : 1.2 sec. (Initial 3 sec.)
0.2mm: 3 sec. (Initial 4 sec.)
0.5sec. (Initial 2.5sec.)
0.3sec. (Initial 2.5sec.)
(The initial time will be different by a condition.)
20-2
20 SPECIFICATIONS
Electronic Angle Measurement
Method
Detecting system
: Absolute reading
: Horizontal : 2 sides
Vertical
: 2 sides
Minimum reading
GPT-8001A/8001
GPT-8002A/8002*
GPT-8003A/8003
GPT-8005A/8005
:
:
:
:
1"/0.5" (0.5mgon/0.1mgon, 5mmil/2mmil) reading
1"/0.5" (0.5mgon/0.1mgon, 5mmil/2mmil) reading
5"/1" (1mgon/0.2mgon, 20mmil/5mmil) reading
5"/1" (1mgon/0.2mgon, 20mmil/5mmil) reading
*Minimum reading of GPT-8002A/8002 will be differed by the market.
Accuracy(Standard deviation based on DIN 18723 )
GPT-8001A/8001 : 1" (0.3mgon )
GPT-8002A/8002 : 2" (0.6mgon )
GPT-8003A/8003 : 3" (1mgon )
GPT-8005A/8005 : 5" (1.5mgon )
: 71mm
Tilt Correction
Method
Automatic vertical and Horizontal index
Liquid type
±4'
1"(0.1mgon)
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
:
:
:
:
e
Diameter of circle
Compensating Range
Correction unit
Others
Instrument height
: 196mm (7.7 in) Base unit detachable
(Height from the tribrach dish to the center of telescope)
Level sensitivity
Circular level
Plate level
: 10'/2mm
: 30"/2 mm
Optical Plummet Telescope
Magnification
Focusing range
Image
Field of view
:
:
:
:
3×
0.5m to infinity
Erect
4°
Laser Plummet (only for Laser plummet type)
Light source
Wave length
Out put
Laser class
:
:
:
:
LD (Visible laser)
633nm
1mW maximum
CLASS 2 (ll) laser product
: 325 (H) × 229 (W) × 211 (L) mm
(12.8 (H) × 8.9 (W) × 8.3 (L) in)
Dimension
Weight
GPT-8000A series (with battery) : 7.7kg ( 17.0 lbs)
GPT-8000 series (with battery)
: 7.5kg ( 16.5 lbs)
Plastic carrying case
: 5.4kg ( 11.9 lbs)
Durability
Protection against water and dust
: IP54 (with BT-56Q)
(Based on the standard IEC60529)
20-3
20 SPECIFICATIONS
Computer unit
OS
Internal Memory
System memory
Main memory
Data memory
Program memory
Application program memory
PC Card Slot
: MS-DOS Ver.3.22
:
:
:
:
:
FEEPROM 512KB
RAM 640 KB
FEEPROM 2 MB
FEEPROM 1 MB
FEEPROM 2 MB
: Based on PC Card Standard 95
(Memory card or ATA card,Type l/ll)
Max. 32MB
Rechargeable Battery BT-56Q (This battery does not contain mercury)
Out put voltage
: 7.2 V
Capacity
: 4.0 Ah
Maximum operating time( when fully recharged, no optical communication) at +20°C (+68°F)
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
GPT-8000A series
Normal use
about 2.5 hours
about 4 hours
about 4 hours
about 4 hours
Distance and Angle measurement
Weight
Battery Charger BC-27BR / BC-27CR
Input voltage
Frequency
Recharging time (at +20°C /+68°F)
Rechargeable battery BT-56Q
Discharging time (at +20°C /+68°F)
Rechargeable battery BT-56Q
Operating temperature
Charging signal
Refreshing signal
Finishing signal
Weight
GPT-8000series
: 0.4kg (0.9 lbs)
: AC 120V(BC-27BR), AC 230V(BC-27CR)
: 50/60Hz
: Approx. 2.5 hours
:
:
:
:
:
:
12 hours (in case of full charge)
+10°C to +40°C ( +50°F to 104°F)
Red lamp illumination
Yellow lamp illumination
Green lamp illumination
0.4kg (0.9 lbs)
● Battery using time will vary depending on environmental conditions and operations done with GPT8000A/8000 series.
20-4
APPENDIX
APPENDIX
Dual Axis Compensation
Inclination of the vertical axis with respect to true vertical will result in incorrectly measured horizontal
angles. The extent of the error in horizontal angle measurement due to axis tilt depends on three
factors :
● the amount of the tilt of axis
● the elevation of the target
● the horizontal angle between the direction of tilt of the vertical axis and the target.
These factors are related by the following formula :
Hzerr = V•sin α • tanh
e
where v = tilt of axis in arcseconds
α = azimuth angle between vert. axis direction and target
h = elevation of target
Hzerr = error in horizontal angle
Example: When the vertical axis is tilted by 30 arcseconds, the target is 10° above the horizon and
rotated 90° in azimuth from the direction of the vertical axis error.
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
1
Hzerr = 30" • sinα • tan10°
Hzerr = 30" • 1 • 0 .176326=5.29"
From the above example it can be seen that horizontal angle errors will increase with steeper vertical
sights (tangent will increase as vertical angle increases) and will be at a maximum when the target is at
right angles (sin 90° =1) to the direction of the vertical axis error. Errors will be at a minimum when the
sights are nearly horizontal (h=0, tan0=0) and in the same direction as the vertical axis error (α=0,
sin0=0). Please refer to the table below to see the relationship between axis tilt (v) and elevation (h) and
the error in horizontal angles which results from these factors.
h 0°
1°
5°
10°
30°
45°
0"
0"
0"
0"
0"
0"
0"
0.09"
0.44"
0.88"
2.89"
5"
0"
0.17"
0.87"
1.76"
5.77"
10"
15"
0"
0.26"
1.31"
2.64"
8.66"
15"
30"
0"
0.52"
2.62"
5.29"
17.32"
30"
1'
0"
1.05"
5.25"
10.58"
34.64"
1'
V
0"
5"
10"
APPENDIX-1
APPENDIX
It is clear from the table that dual axis compensation has the most benefit when the elevation
of the target is greater then 30° and the axis is tilted more than 10". The entries indicated in
bold in the table show, in fact, that for many common surveying applications i.e. target elevation
<30° and axis error <10", virtually no correction would be required. Dual axis compensation is
especially suited then for applications where the sights are very steep.
Even though the compensators can correct horizontal angles for vertical axis errors,
it is still important to use care in setting up the instrument.
Centering error, for instance, cannot be corrected by the compensators. If the vertical axis is
tilted by 1’ with the instrument 1.4meters above the ground, a centering error of approx. 0.4mm
will result. The maximum effect of this error at 10m is about 8" of horizontal angle error.
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
In order to maintain the increased accuracy possible through dual axis compensation, it is
necessary to keep the compensators in proper adjustment.The compensators must agree with
the actual level condition of the instrument. Through various environmental stresses, the
agreement between the level condition sensed by the compensators and the true level condition
of the instrument may be disturbed. In order to reestablish the correct relationship between the
compensator and the true level condition of the instrument, it is necessary to carry out the
vertical indexing procedure listed on Section 9.4“Adjustment of Compensation Systematic Error of
Instrument” . This adjustment will both reset the vertical index (cause a direct + indirect zenith
reading to the same elevation to equal 360°) and zero the level reference for the horizontal
compensator. While correct vertical angles can be obtained by averaging direct and indirect
reading even when the index is improperly adjusted, the same is not true for horizontal angles.
Since the vertical axis error is fixed for a given setup, its effect cannot be removed by
averaging two readings.
For this reason, it is extremely important to maintain the vertical indexing adjustment to
insure proper correction of the horizontal angles.
APPENDIX-2
APPENDIX
Precaution when Charging or Storing Batteries
The capacity of battery will be affected and its service life shortened in any of the following cases while
it is recharged, discharged or stored.
1) Recharging
Fig. 1 shows how ambient temperature at recharging is related to charging efficiency or as affecting
discharge capacity. As seen from the figure, charging at normal temperature is best, and the
efficiency decreases as the temperature rises. It is best, therefore, to always recharge the battery at
normal temperature to obtain full use of battery capacity and enjoy maximum operation per charge.
And the service life of your battery will be shortened if it is frequently overcharged or recharged at
high temperature.
Note: 0.1C charge means that the battery is recharged with 0.1 -time current as against its
capacity.
e
2) Discharge
Fig. 2 shows discharge temperature characteristics. Discharge characteristics at high temperature
are the same as those at normal temperatures. The battery is likely to have reduced discharge
capacity as well as lower discharged voltage when discharged at low temperature. And the service
life of your battery will be shortened if it is greatly overcharged.
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
2
Note: 1C discharge means one with 1 -time current over battery capacity.
3) Storage
See Fig. 3 for how storing period at different temperature levels is related to the remaining capacity.
The battery will lose its capacity as storage temperature rises and the storage period increases.
This does not mean, however , that the battery performance is damaged when the battery is stored.
The battery, reduced in capacity, will be restored once it is recharged. Always recharge your battery
before use. And recharge and discharge the battery 3 or 4 times to restore its capacity if it has been
stored for a long period or at high temperature. Storing at high temperature can adversely affect the
service life of your battery.
Your battery has been fully charged before leaving the factory, but its capacity may be affected
considerably when it takes several months to reach you, if it is stored at high temperature area or
passes through a high-temperature region. Then, the battery must be recharged and discharged
3~4 times to fully restore its capacity.
And the battery should always be stored at normal temperature or lower if it will not be used for any
long period. This helps your battery have a longer service life.
APPENDIX-3
Charging efficiency (discharge capacity
APPENDIX
120
100
0.1C charge
80
60
Discharge : 0.2,
Temperature at
discharge : 20
40
E.V.=
20
0
0
60
30
40
50
20
Ambient temperature when charging i
j
10
e
Fig.1 Recharging
j
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
120
Discharge capacity i
100
0.2C discharge
80
1C discharge
60
Charging : 0.1C ~16hours
Charging temperature : 20
40
20
0
-20
0
60
20
40
Ambient temperature i
j
Remaining capacity ratio i
j
Fig. 2 Discharge
100
0
80
20
60
40
Charging : 0.1C ~16hours
Discharge : 0.2 C, E.V.=1.0V
20
45
60
0
0
1
2
Storing period (month)
Fig. 3 Storage
APPENDIX-4
3
END USER LICENSE AGREEMENT
IMPORTANT-- READ CAREFULLY BEFORE USING THE EMBEDDED SYSTEM WHICH CONTAINS MICROSOFT SOFTWARE. By using the embedded system containing software, you indicate your acceptance of
the following Software License Agreement.
SOFTWARE LICENSE AGREEMENT
(Embedded Products)
This software license agreement, including the Warranty and Special Provisions set forth in the appendix or separate booklet included in this package, is a legal agreement between you (either an individual or an entity, hereinafter "End User") and the manufacturer ("Embedded System Manufacturer") of the embedded system containing
software product. By using the embedded system on which software program(s) have been pre installed ("SOFTWARE"), you are agreeing to be bound by the terms of this agreement.
1.GRANT OF LICENSE. This License Agreement permits you to use the Microsoft SOFTWARE as preinstalled
on the embedded system.
2. INTELLECTUAL PROPERTY. GPT-8000A/8000 SERIES contains intellectual property, i.e., software programs,
that is licensed for the end user customer's use (hereinafter "End User"). This is not a sale of such intellectual
property. The End User shall not copy, disassemble, reverse engineer, or decompile the software program.
e
3.COPYRIGHT. The SOFTWARE is owned by Microsoft Corporation or its suppliers and is protected by United
States copyright laws and international treaty provisions and all other applicable national laws. Therefore, you
must treat the SOFTWARE like any other copyrighted material.
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
4.U.S. GOVERNMENT RESTRICTED RIGHTS. The SOFTWARE and documentation are provided with RESTRICTED RIGHTS. Use, duplication, or disclosure by the United States Government is subject to restrictions as
set forth in subparagraph (c)(1)(ii) of The Rights in Technical Data and Computer Software clause at DFARS
252.227-7013 or subparagraphs (c)(1) and (2) of the Commercial Computer Software -- Restricted Rights at 48
CFR 52.227-19, as applicable. Manufacturer is Microsoft Corporation/One Microsoft Way/Redmond, WA 980526399.
Please see the Warranty and Special Provisions for information concerning governing law.
Product support for the SOFTWARE is not provided by Microsoft Corporation or its subsidiaries. For product support, please refer to Embedded System Manufacturer's support number provided in the documentation for the embedded system. Should you have any questions concerning this Agreement, or if you desire to contact Embedded
System Manufacturer for any other reason, please refer to the address provided in the documentation for your embedded system.
FOR THE LIMITED WARRANTY AND SPECIAL PROVISIONS PERTAINING TO YOUR COUNTRY, PLEASE REFER TO EMBEDDED SYSTEM DOCUMENTATION OR THE WARRANTY AND SPECIAL PROVISIONS BOOKLET INCLUDED IN THIS PACKAGE.
APPENDIX
WARRANTY AND SPECIAL PROVISIONS
LIMITED WARRANTY
LIMITED WARRANTY. Embedded System Manufacturer warrants that (a) the SOFTWARE will perform substantially in accordance with the accompanying written materials for a period of ninety (90) days from the date of receipt. Any implied warranties on the SOFTWARE are limited to ninety (90) days. Some states/jurisdictions do not
allow limitations on duration of an implied warranty, so the above limitation may not apply to you.
CUSTOMER REMEDIES. Embedded System Manufacturer's and its suppliers' entire liability and your exclusive
remedy shall be, at Embedded System Manufacturer's option, either (a) return of the price paid, or (b) repair or
replacement of the SOFTWARE that does not meet the above Limited Warranty and which is returned to Embedded System Manufacturer with a copy of your receipt. This Limited Warranty is void if failure of the SOFTWARE
has resulted from accident, abuse, or misapplication. Any replacement SOFTWARE will be warranted for the remainder of the original warranty period or thirty (30) days, whichever is longer.
NO OTHER WARRANTIES. THE MICROSOFT SOFTWARE PROGRAMS ARE PROVIDED TO THE END
USER "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING, BUT
NOT LIMITED TO, WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
THE ENTIRE RISK OF THE QUALITY AND PERFORMANCE OF THE SOFTWARE PROGRAM IS WITH YOU.
NO LIABILITY FOR CONSEQUENTIAL DAMAGES. EMBEDDED SYSTEM MANUFACTURER'S AND ITS SUPPLIERS' SHALL NOT BE HELD TO ANY LIABILITY FOR ANY DAMAGES SUFFERED OR INCURRED BY THE
END USER (INCLUDING, BUT NOT LIMITED TO, GENERAL, SPECIAL, CONSEQUENTIAL OR INCIDENTAL
DAMAGES INCLUDING DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, LOSS
OF BUSINESS INFORMATION AND THE LIKE), ARISING FROM OR IN CONNECTION WITH THE DELIVERY,
USE OR PERFORMANCE OF THE SOFTWARE PROGRAM.
SPECIAL PROVISIONS
This Software License Agreement and Warranty are governed by the laws of the State of Washington, U.S.A.
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
AUTO TRACKING TOTAL STATION
GPT-8000A series
SERVO TOTAL STATION
D
w ocu
w m
w
.k en
ol to
ln d
er e
la sc
br ar
an ga
a. do
cl
d
e
GPT-8000 series
TOPCON POSITIONING SYSTEMS, INC.
5758 West Las Positas Blvd., Pleasanton, CA 94588, U.S.A.
Phone: 925-460-1300 Fax: 925-460-1315 www.topcon.com
TOPCON CALIFORNIA
3380 Industrial Blvd, Suite 105, West Sacramento, CA 95691, U.S.A.
Phone: 916-374-8575 Fax: 916-374-8329
TOPCON MIDWEST
891 Busse Road, Elk Grove Village, IL 60007, U.S.A.
Phone: 847-734-1700 Fax: 847-734-1712
TOPCON EUROPE B.V.
Essebaan 11, 2908 LJ Capelle a/d IJssel, The Netherlands.
Phone: 010-4585077 Fax: 010-4585045 www.topconeurope.com
Preenakker 8, 1785 Merchtem, Belgium
Phone: 052-37.45.48 Fax: 052-37.45.79
Weidkamp 180, 45356 Essen, GERMANY
Phone: 0201-8619-100 Fax: 0201-8619-111 ps@topcon.de
www.topcon.de
TOPCON S.A.R.L.
89, Rue de Paris, 92585 Clichy, Cedex, France.
Phone: 33-1-41069490 Fax: 33-1-47390251 topcon@topcon.fr
TOPCON ESPAÑA S.A.
HEAD OFFICE
Frederic Mompou 5, ED. Euro 3, 08960, Sant Just Desvern Barcelona, Spain.
Phone: 93-473-4057 Fax: 93-473-3932 www.topconesp.com
TOPCON SCANDINAVIA A. B.
Neongatan 2 S-43151 Mölndal, SWEDEN
Phone: 031-7109200 Fax: 031-7109249
Topcon House Kennet Side, Bone Lane, Newbury, Berkshire RG14 5PX U.K.
Phone: 44-1635-551120 Fax: 44-1635-551170
survey.sales@topcon.co.uk laser.sales@topcon.co.uk
TOPCON SOUTH ASIA PTE. LTD.
Blk 192 Pandan Loop, Pantech Industrial Complex, #07-01, Singapore 128381
Phone: 62780222 Fax: 62733540 www.topcon.com.sg
TOPCON AUSTRALIA PTY. LTD.
408 Victoria Road, Gladesville, NSW 2111, Australia
Phone: 02-9817-4666 Fax: 02-9817-4654 www.topcon.com.au
TOPCON INSTRUMENTS (THAILAND) CO., LTD.
TOPCON INSTRUMENTS (MALAYSIA) SDN. BHD.
TOPCON DEUTSCHLAND G.m.b.H.
Avenida Burgos, 16E, 1∞28036, Madrid, Spain.
Phone: 91-302-4129 Fax: 91-383-3890
HEAD OFFICE
77/162 Sinn Sathorn Tower, 37th Fl.,
Krungdhonburi Rd., Klongtonsai, Klongsarn, Bangkok 10600 Thailand.
Phone: 662-440-1152~7 Fax: 662-440-1158
TOPCON BELGIUM
MADRID OFFICE
TOPCON (GREATBRITAIN) LTD.
Lot 226 Jalan Negara 2, Pusat Bandar Taman Melawati,
Taman Melawati, 53100, Kuala Lumpur, Malaysia.
Phone: 03-41079801 Fax: 03-41079796
TOPCON KOREA CORPORATION
2F Yooseoung Bldg., 1595-3, Seocho-Dong, Seocho-gu, Seoul, 137-876, Korea.
Phone: 82-2-2055-0321 Fax: 82-2-2055-0319 www.topcon.co.kr
TOPCON OPTICAL (H.K.) LIMITED
2/F., Meeco Industrial Bldg., No. 53-55 Au Pui Wan Street, Fo Tan Road,
Shatin, N.T., Hong Kong
Phone: 2690-1328 Fax: 2690-2221 www.topcon.com.hk
TOPCON CORPORATION BEIJING OFFICE
Room No. 962 Poly Plaza Building, 14 Dongzhimen Nandajie,
Dongcheng District, Beijing, 100027, China
Phone: 10-6501-4191~2 Fax: 10-6501-4190
TOPCON CORPORATION BEIRUT OFFICE
P. O. BOX 70-1002 Antelias, BEIRUT-LEBANON.
Phone: 961-4-523525/961-4-523526 Fax: 961-4-521119
TOPCON CORPORATION DUBAI OFFICE
P.O.Box 28595, 102, Al Naily Bldg., 245 Abu Hail Road, Deira,Dubai,UAE
Phone: 971-4-2696511 Fax: 971-4-2695272
TOPCON CORPORATION
75-1 Hasunuma-cho, Itabashi-ku, Tokyo 174-8580, Japan
Phone: 3-3558-2520 Fax: 3-3960-4214 www.topcon.co.jp
64538 90020 GPT-8000/8000A Series A 0207 (2B)