Shimaden, Temperature and Humidity Control Specialists
°C
%RH
Series
SD16 & KR16
SHIMADEN DIGITAL INDICATORS
&
®
NRTL /C
approved
BASIC FEATURES
DIN Size 48 x 96 mm
± 0.3% High Accuracy Indication
Large 20 mm bright display
Make reading from long distance and low light location easier
Multi-inputs & Multi-ranges
User selectable Thermocouple, RTD, V, mV and Current inputs
A 250Ω resistor is required across the input terminal for 4-20mA DC
Inverse scaling possible
With voltage and current input signals, normal and inverse scaling
is possible.
Additionally, normal and inverse scaling is possible for the analog
output signals.
Dust and splash proof front panel
Equivalent to IP66
Wide range of optional features
Alarms, analog output signals and communication interface
(RS232C or RS485) available
A six-point selector switch, (the KR16 series), is available for
combined use.
SPECIFICATIONS
Series
SD16
Display
• Digital display
• Action display
• Display accuracy
• Display accuracy range
• Display resolution
• Measured value display range
• Display update cycle
: Process value (PV) 7 segment Red LED 4 digits (H: 20mm)
: 1 point of parameter display (SET) by green LED
: 1 point of communication display (COM) by green LED
: 2 points of alarm (AL1, AL2) by red LED
: ±(0.3% FS+1 digit) within measuring range
: Excluding cold junction temperature compensation accuracy in the case of
thermocouple input
: ±5%FS for temperature below 400˚C of thermocouple B
: When the thermocouple [T, U] indication value is 0~100˚C, 0.5%FS and
when it is below -100˚C, 1%FS
: 23˚C±5˚C (18~28˚C)
: Depends on measuring range (0.001, 0.01, 0.1, 1)
: -10~110% of measuring range (Accuracy guaranteed for value is within
measuring range only)
: For R.T.D. input of -200~600˚C: 210~680˚C
: For thermocouple [K] input of -199.9~800˚C: -273.1~900.0 ˚C
: 0.5~5.0 seconds (0.5 steps)
When 0.5 second or more is set, there may occur a difference among the
displayed value, the analog output and the communication data.
Setting
• Setting
• Setting range
: By four (4) front key switches
: Same as measuring range
Input
• Type of input
• Thermocouple
•
•
•
•
External resistance
Input impedance
Burnout
Cold junction temperature
compensation accuracy
• R.T.D.
• Amperage
• Lead wire tolerable resistance
•
•
•
•
•
•
Voltage (mV)
Voltage (V)
Input impedance
Current
Input impedance
Input scaling function
•
•
•
•
•
•
•
Scaling range
Span
Position of decimal point
Sampling cycle
PV bias
PV filter
Isolation
: Three-type multiple input of Thermocouple, R.T.D., Voltage (mV, V)
: B, R, S, K, E, J, T, N, {U, L (DIN 43710)}, WRe5-26
Refer to measuring range code table
: 100Ω max.
: 500KΩ max.
: Standard feature (Up-scale)
: ±1˚C (18~28˚C range)
: ±2˚C (5~18˚C, 28~45˚C range)
(±5˚C to the negative side of measuring range in case of T and U input)
: JIS Pt100Ω 3-wire type
: Approx. 0.25mA
: 5Ω max. / wire (3 lead wire should have same resistance)
When the resistance value of each wire is same
0~5Ω: 0.05˚C, 5~10Ω: 0.2˚C, 10~20Ω: 0.6˚C, 20~30Ω: 1.4˚C max.
: 0~10mV DC
: 0~5V, 1~5V, 0~10V DC
: 500KΩ min.
: 4~20mA DC
: 250Ω [A shunt resistor (option) needs to be connected to the terminal]
: Scaling possible for voltage (mV, V) or current (mA) input and inverse
scaling possible.
: -1999~9999 unit
: 10~5000 unit
: None, 0.0, 0.00, 0.000
: 0.5 seconds
: ±200 unit
: 0~100 seconds (0 = without filter)
: Between input and analog output
Alarm output (option)
• Number of alarm points
• Alarm type
•
•
•
•
•
Alarm
Alarm
Alarm
Alarm
Alarm
setting range
action
sensitivity
output / rating
output update cycle
: 2 (AL1 and AL2) for both normal open and common
: Selectable from combinations of the following 4 types
: High limit absolute value without inhibit action
: High limit absolute value with inhibit action
: Lower limit absolute value without inhibit action
: Lower limit absolute value with inhibit action
: Within measuring range or within full scaling range
: ON-OFF action
: 1~999 unit Within measuring range
: Contact 1a (common) / 240V, AC1.5A (resistive load)
: 0.5 seconds
SPECIFICATIONS
Series
SD16
Analog output (option)
• Analog output type
•
•
•
•
Output
Output
Output
Output
resolution
accuracy
scaling
update cycle
: 0~10mV DC (output resistance: 10Ω)
: 0~10V DC (load current: 1mA max.)
: 4~20mA DC (load resistance: 300Ω max.)
: Approx. 0.03% (1/3000)
: ±(0.3%FS + 1 digit) of display value
: Within measuring range (inverse scaling possible)
: 0.5 seconds
Communication (option)
•
•
•
•
Communication type
Communication system
Communication speed
Data bit length
•
•
•
•
Communication address
Multi-drop connection
Communication delay
Communication code
: RS-232C, RS-485
: Half duplex start-stop synchronized system
: 1200, 2400, 4800, 9600, 19200 bps
: 7 bit even parity 1 stop bit
8 bit non parity 1 stop bit
: 1~255
: 31 max. (with RS-485)
: 0~50.0 milli-seconds
: ASCII code
Others
• Data storage
• Ambient conditions for use
Temperature and Humidity
• Height
• Installation category
• Degree of pollution
• Power supply voltage
• Power consumption
• Applicable standard
Safety
EMC
• Dust proof/Drip proof
• Insulation resistance
• Dielectric strength
•
•
•
•
•
•
Case material
External dimensions
Mounting
Panel thickness
Panel cutout
Weight
: By non volatile memory (EEPROM)
: -10~50˚C/90%R max. (on condition that there is no dew condition)
: 2000m above sea level or lower
: Category II
: Degree 2
: 100~240V AC±10%, 50/60Hz
24V AC/DC ±10% (option)
: 11VA (AC) max., 7W (DC) max.
: IEC 1010-1 and EN61010-1
: EN61326
(EMC testing Display accuracy: +5% FS)
: IP66 (Complies with the IEC 529-IP66)
: Between input/output terminal and power supply terminal:
500V DC 20MΩ minimum
: Between input/output terminal and protective conductor terminal
500V DC 20MΩ minimum
: 1 min. at 2300V AC between input/output terminal and power supply
terminal
: 1 min. at 1500V AC between power supply terminal and protective
conductor terminal
: PPO resin molding (equivalent to UL94V-1)
: H48 x W96 x D110 mm
: Push-in panel (one-touch mount)
: 1.0~4.0 mm
: H45 x W92 mm
: Approx. 250g
SPECIFICATIONS
Series
KR16
Selector KR16 series
•
•
•
•
•
•
•
•
•
•
•
•
No. of switching points
No. of switching circuits
Switching operation method
Applicable signal contact rating
Contact method
Voltage
Current
Contact resistance
Operating ambient temperature range
Operating ambient humidity range
Material
Color
•
•
•
•
•
External dimensions
Panel cutout
Mounting
Panel thickness
Weight
:6
:2
: Push button switching
: DC voltage, current (R.T.D.is not applicable)
: Contact slide
: 30V DC max.
: 100mA DC max.
: 300m Ω max.
: -10~50˚C
: 90% RH max.
: PPO resin
: Case
: Munsell No. N-1 or compatible
Front Panel: Munsell No. N-1 or compatible
: H48 x W96 x D118 (panel depth: 100) mm
: H45 x W92 mm
: Push-in panel (one-touch mount)
: 1.0~4.0 mm
: Approx. 250g
APPLICATION EXAMPLE
1. Selection of T. C. Switching
2. Selection of Voltage Switching
T. C.
T. C.
Compensating Lead Wire
Converter
Copper Lead Wire
Compensating Lead Wire
Copper Lead Wire
KR16
Indicator
Voltage
KR16
Recorder
R. T. D.
Indicator
Converter
Recorder
3. Selection of Analog Output (Voltage)
4. Installation Example With SD16
Control Signal
Controller
SD16
Analog Output
SD16
KR16
Controller
Indicator
KR16
Analog Output
K R 1 6
Control Signal
Recorder
ORDERING INFORMATION
1
ITEM
SERIES
Series
CODE
SD164
2
INPUT
8
9008-
3
POWER SUPPLY
4
ALARM OUTPUT (OPTION)
0
1
0
3
4
6
5
ANALOG OUTPUT (OPTION)
6
COMMUNICATION FUNCTION (OPTION)
7
REMARKS
0
5
7
0
9
SD16
SPECIFICATIONS
Digital Indicator
DIN Size 48 × 96 mm
Current (4~20mA DC)
A shunt resistor (option) needs to be connected to the terminal
*Thermocouple B, R, S, K, E, J, T, N,
{U, L (DIN 43710)}
Value set at
K 0~1200C
Multi input
*R.T.D. Pt100Ω
when shipped
*Voltage (mV, V) 0~10mV DC, 0~5V DC,
0~10V DC, 1~5V DC
100~240V AC±10% (50/60Hz)
24V AC ±10% (50/60Hz) / 24V DC ±10%
None
Individual setting, individual output 2 points (1c contact)
Contact capacity: 250V AC 1.5A / resistive load
None
0~10mV DC
Output resistance: 10Ω
4~20mA DC
Load resistance: 300Ω max.
0~10V DC
Load resistance: 1mA max.
None
RS-485
RS-232C
Without
With (Please consult before ordering)
MEASURING RANGE CODES
INPUT
TYPE
B
R
S
K
K
E
THERMOCOUPLE
J
T
N
∗1
U
L
∗1
∗2 WRe5-26
Pt100Ω
R.T.D.
Pt100Ω
0~10mV
0~ 5V
VOLTAGE
1~ 5V
0~10V
CURRENT
4~20mA
CODE
01
02
03
04
05
06
07
08
09
10
11
12
31
32
71
81
82
83
95
RANGE (ºC)
0
~ 1800
0
~ 1700
0
~ 1700
-199.9
~
800.0
0
~ 1200
0
~
700
0
~
600
-199.9
~
300.0
0
~ 1300
~
300.0
-199.9
0
~
600
0
~ 2300
-200
~
600 ∗3
-100.0
~
100.0
Initial value: 0.0~100.0
Scaling setting range:
-1999~9999
Span: 10~5000 counts
RANGE
0
~
0
~
0
~
-300
~
0
~
0
~
0
~
-300
~
0
~
-300
~
0
~
0
-300
~
-150.0 ~
(ºF)
3300
3100
3100
1500
2200
1300
1100
600
2300
600
1100
4200
1100
200.0
Thermocouple B, R, S, K, E, J, T,
N: JIS/ANSI/IEC
∗1 Thermocouple U, L: DIN 43710
∗2 Thermocouple WRe5-26: Made
of Hoskins
∗3: -200.0 ~ 600.0 ºC range available. Please specify when ordering.
ORDERING INFORMATION
1
ITEM
SERIES
2
REMARKS
CODE
KR160
9
Series
SPECIFICATIONS
Push button six-point selector
Without
With (Please consult before ordering)
KR16
EXTERNAL DIMENSIONS & TERMINAL ARRANGEMENT
SD16 & KR16
Series
• SD16
External Dimensions
Terminal Arrangement
AL1 AL2
11
96
111
100
11
48
AL2
SET
COM
12
13
SD
RD
RS-485 SG
+
-
+
-
17
18
19
14
44.6X91.6
AL1
Communication Analog output
RS-232C SG
ENT
15
16
+
attached externally)
-
V
R.T.D.
R.T.D.
A
SD16
L 50/60Hz N
1
92+0.8
0
B
3
4
5
6
7
8
9
10
60min.
2
B
+ mV + T.C. -
100-240V AC
Panel Cutout
45+0.6
0
20
mA (250Ω register
110min.
(Unit : mm)
(Unit : mm)
• KR16
External Dimensions
18
96
Terminal Arrangement
118
100
OUTPUT
6
3
4
5
6
44.6X91.6
2
48
1
KR16
+
-
+
-
11
12
13
14
15
16
17
18
19
20
1
2
3
4
5
6
7
8
9
10
+
-
+
-
+
-
+
-
+
1
2
3
INPUT
4
5
Panel Cutout
Panel Cutout
110min.
92+0.8
0
93+10
45+0.6
0
In case installed
with SD16
92+0.8
0
(Unit : mm)
(Unit : mm)
Warning
• The SD16 & KR16 series is designed for the control of temperature, humidity and other physical values of general
industrial equipment. (It is not to be used for any purpose which regulates the prevention of serious effects on human life
or safety.)
Caution
• If the possibility of loss or damage to your system or property as a result of failure of any part of the process exists, proper
safety measures must be made before the instrument is put into use so as to prevent the occurrence of trouble.
ISO 9001
(The contents of this brochure are subject to change without notice.)
Temperature and Humidity Control Specialists