DSC-F717
ADJ
SECTION 6
ADJUSTMENTS
Ver 1.0 2002. 09
Revision History
Link
SERVICE MODE
Before starting adjustments
Adjusting items when replacing main parts and boards
ADJUSTING REMOTE COMMANDER
DATA PROCESS
CAMERA SECTION ADJUSTMENTS
SERVICE MODE
PREPARATIONS BEFORE ADJUSTMENTS
INITIALIZATION OF A, B, D, E, F, 7, 9 PAGE DATA
VIDEO SYSTEM ADJUSTMENTS
CAMERA SYSTEM ADJUSTMENTS
LCD SYSTEM ADJUSTMENTS
COLOR ELECTRONIC VIEWFINDER SYSTEM ADJUSTMENTS
Contents of LEVEL 2 and LEVEL 3 Service Manual
CONTENTS
1. SERVICE NOTE
2. DISASSEMBLY
3. BLOCK DIAGRAMS
4. PRINTED WIRING BOARDS AND
SCHEMATIC DIAGRAMS
5. REPAIR PARTS LIST
9-929-994-51
LEVEL 2
a
a
OVERALL
POWER
CD-408, FR-194, PD-179,
BT-015, LB-082, AL-013,
UJ-002, AJ-005, SW-379
BOARD, FP-583, FP-584
FLEXIBLE
CONTROL SWITCH
BLOCK (FZ51050)
CONTROL SWITCH
BLOCK (PW51050)
EXPLODED VIEWS
ELECTRICAL PARTS LIST
LEVEL 3
✕
✕
✕
SY-080 BOARD
Sony EMCS Co.
✕
a
(SY-080 BOARD)
2002I0500-1
©2002.9
Published by DI Customer Center
DSC-F717
TABLE OF CONTENTS
Section
6.
Title
Page
ADJUSTMENTS
Before Starting Adjustment ······················································· 6-1
1-1. Adjusting Items when Replacing
Main Parts and Boards ···················································· 6-2
6-1. Camera Section Adjustments ··········································· 6-3
1-1. Preparations Before Adjustments ···································· 6-3
1-1-1. List of Service Tools ························································ 6-3
1-1-2. Preparations ····································································· 6-4
1-1-3. Discharging of the Flashlight Power Supply ··················· 6-4
1-1-4. Precautions ······································································ 6-6
1.
Setting the Switch ···························································· 6-6
2.
Order of Adjustments ······················································ 6-6
3.
Subjects ··········································································· 6-6
4.
Preparing the Flash Adjustment Box ······························· 6-7
1-2. Initialization of A, B, D, E, F, 7, 9 Page Data ················· 6-8
1-2-1. Initialization of A, D Page Data ······································ 6-8
1.
Initializing A, D Page Data ·············································· 6-8
2.
Modification of A, D Page Data ······································ 6-8
3.
A Page Table ···································································· 6-8
4.
D Page Table ···································································· 6-8
1-2-2. Initialization of B, E, F, 7, 9 Page Data ··························· 6-9
1.
Initializing B, E, F, 7, 9 Page Data ·································· 6-9
2.
Modification of B, E, F, 7, 9 Page Data. ·························· 6-9
3.
B Page Table ···································································· 6-9
4.
E Page Table ···································································· 6-9
5.
F Page Table ·································································· 6-10
6.
7 Page Table ··································································· 6-12
7.
9 Page Table ··································································· 6-12
1-3. Video System Adjustment ············································· 6-13
1.
Composite Video Level Adjustment ······························ 6-13
1-4. Camera System Adjustments ········································· 6-14
Data Setting During Camera System Adjustments ········ 6-14
Picture Frame Setting ···················································· 6-15
Check on the Oscilloscope ············································ 6-15
1.
HALL Adjustment ························································· 6-16
2.
Flange Back Adjustment
(Using the minipattern box) ·········································· 6-17
3.
Flange Back Adjustment
(Using the flange back adjustment chart and
Subject More than 500 m Away) ··································· 6-18
4.
Flange Back Check ························································ 6-19
5.
F No. Compensation ······················································ 6-20
6.
Mechanical Shutter Adjustment ···································· 6-20
7.
Light Value Adjustment ················································· 6-21
8.
Mixed Color Cancel Adjustment ··································· 6-21
9.
Auto White Balance 3200K Standard Data Input 1 ······ 6-22
10. Auto White Balance 3200K Standard Data Input 2 ······ 6-22
11. Auto White Balance 3200K Standard Data Input 3 ······ 6-23
12. Auto White Balance 5800K Standard Data Input 1 ······ 6-23
13. Auto White Balance 5800K Standard Data Input 2 ······ 6-24
14. Auto White Balance 5800K Standard Data Input 3 ······ 6-24
15. Auto White Balance 5800K Check 1 ···························· 6-25
16. Auto White Balance 5800K Check 2 ···························· 6-26
17. Auto White Balance 5800K Check 3 ···························· 6-26
18. Auto White Balance 3200K Check 1 ···························· 6-27
19. Auto White Balance 3200K Check 2 ···························· 6-28
20. Auto White Balance 3200K Check 3 ···························· 6-28
21. Color Reproduction Adjustment ···································· 6-29
22. CCD White Defect Compensation ································ 6-30
23. CCD Black Defect Compensation ································· 6-31
24. CCD Linearity Check (Monitoring) ······························ 6-32
25. CCD Linearity Check (Caputure) ·································· 6-34
26. Strobe White Balance Adjustment ································· 6-35
27. LED Illumination Check ··············································· 6-36
28. AF Illumination Check ·················································· 6-37
Section
Title
Page
1-5.
1.
2.
3.
4.
5.
6.
7.
8.
1-6.
1.
2.
3.
4.
5.
6-2.
2-1.
1.
2.
LCD System Adjustments ············································· 6-38
LCD Initial Data Input (1) ············································· 6-39
LCD Initial Data Input (2) ············································· 6-39
VCO Adjustment (PD-179 Board) ································ 6-40
D Range Adjustment (PD-179 Board) ··························· 6-40
Contrast Adjustment (PD-179 Board) ··························· 6-41
V-COM Level Adjustment (PD-179 Board) ·················· 6-41
V-COM Adjustment (PD-179 Board) ···························· 6-42
White Balance Adjustment (PD-179 Board) ················· 6-42
Color Electronic Viewfinder System Adjustments ········ 6-43
EVF Initial Data Input ··················································· 6-44
VCO Adjustment (PD-179 Board) ································ 6-44
Bright Adjustment (PD-179 Board) ······························ 6-45
Contrast Adjustment (PD-179 Board) ··························· 6-45
White Balance Adjustment (PD-179 Board) ················· 6-46
Service Mode ································································· 6-47
Adjusting Remote Commander ····································· 6-47
Used the Adjusting Remote Commander ······················ 6-47
Precautions upon Using the Adjusting
Remote Commander ······················································ 6-47
2-2. Data Process ·································································· 6-48
2-3. Service Mode ································································· 6-49
1.
Setting the Test Mode ···················································· 6-49
2.
Bit Value Discrimination ··············································· 6-49
3.
Mode Dial Check (1) ····················································· 6-50
4.
Mode Dial Check (2) ····················································· 6-50
5.
Jog Dial Check ······························································ 6-50
6.
Switch Check (1) ··························································· 6-50
7.
Switch Check (2) ··························································· 6-51
8.
LED Check ···································································· 6-51
9.
Self Diagnosis Code ······················································ 6-51
—2—
* The sheet for auxiliary light is shown on page 6-52.
* The color reproduction frame is shown on page 6-53.
DSC-F717
SECTION 6
ADJUSTMENTS
COVER
Before starting adjustment
EVR Data Re-writing Procedure When Replacing Board
The data that is stored in the repair board, is not necessarily correct.
Perform either procedure 1 or procedure 2 or procedure 3 when replacing board.
Procedure 1
Save the EVR data of the machine in which a board is going to be replaced. Download the saved data after a
board is replaced.
(Machine before starting repair)
PC
PC
Save the EVR data
to a personal computer.
(Machine after a board is replaced)
Download the saved
data to a machine.
Procedure 2
Remove the EEPROM from the board of the machine that is going to be repaired. Install the removed EEPROM
to the replaced board.
Remove the EEPROM and install it.
(New board)
(Former board)
Procedure 3
When the data cannot be saved due to defective EEPROM, or when the EEPROM cannot be removed or installed, save the data from the same model of the same destination, and download it.
(Machine to be repaired)
PC
(Machine to be repaired)
Download the data.
Save the data.
(The same model of the same destination)
After the EVR data is saved and downloaded, check the
respective items of the EVR data.
(Refer to page 6-2 for the items to be checked.)
6-1
DSC-F717
COVER
1-1. Adjusting items when replacing main parts and boards
When replacing main parts and boards, adjust the items indicated by z in the following table.
Replaced parts
(EVF LCD panel)
(Back light (EVF))
(S/H, AGC, A/D)
(EVR)
(VIDEO AMP)
(LCD drive)
(LCD Timing generator)
(LCD drive (EVF))
(LCD Timing generator (EVF))
LCD902
D701
IC102
IC207
IC201
IC801
IC802
IC901
IC902
(COMPLETE)
(COMPLETE)
(COMPLETE)
EVF block
LB-082 board
SY-080 board
SY-080 board
FR-194 board
PD-179 board
PD-179 board
PD-179 board
PD-179 board
FR-194 board
PD-179 board
SY-080 board
EEPROM
(Back light unit)
D911
Initialization of A, B, D, Initialization of A, D page data
E, F, 7, 9 page data
Initialization of B, E, F, 7, 9 page data
IC505
RadarW
SY-080 board
Supporting
RadarW
(LCD panel)
LCD901
replacement
LCD block
Laser unit
Flash unit
Adjustment
Lens block assy
Adjustment section
Board
Mounted parts
replacement
LCD block
Block
replacement
z z
z z
Video
Composite video level adj.
Camera
Hall adj.
z
Flange back adj.
z
F No. compensation
z
Mechanical shutter adj.
z
Light value adj.
z
z
z z z
Mixed color cancel adj.
z
z
z z z
Auto white balance standard data input
z
z
z z z
Color reproduction adj.
z
z
z z z
CCD (white and black) defect compensation
z
CCD linearity check
z
Strobe white balance adj.
z z
z z
AF Illumination check
LCD
z
z
z z z
z z z
z
z z z
z z z
z
z z
z
z z z
z
z
LCD initial data input
z z
VCO adj.
z
z z z
D range adj.
z
z z z
Contrast adj.
z
z z z
V-COM level adj.
EVF
z z
z z z
z
z z z
V-COM adj.
z
z
z z z
White balance adj.
z z
z
z z z
EVF initial data input
z z
VCO adj.
z
z z z
Bright adj.
z
z z z
Contrast adj.
z
z z z
z
z z z
White balance adj.
z z
Table 6-1-1
6-2
DSC-F717
COVER
6-1. CAMERA SECTION ADJUSTMENTS
1-1.
PREPARATIONS BEFORE ADJUSTMENTS
1-1-1. List of Service Tools
• Oscilloscope
• Color monitor
• Vectorscope
• Regulated power supply
• Digital voltmeter
• Frequency counter
• Calculating machine capable of calculating hexadecimal numbers.
Ref. No.
Name
Parts Code
Usage
J-1
Filter for color temperature correction (C14)
Auto white balance adjustment/check
J-6080-058-A
White balance adjustment/check
J-2
J-3
Pattern box PTB-450
Color bar chart for pattern box
J-6082-200-A
J-6020-250-A
J-5
Adjusting remote commander (RM-95 upgraded).
(Note 1)
Siemens star chart
J-6080-875-A For checking the flange back
J-6
Clear chart for pattern box
J-6080-621-A
J-7
CPC-12 jig
J-6082-436-A
J-8
Minipattern box
J-6082-353-B For adjusting the flange back
J-9
Back ground paper
J-2501-130-A For adjusting the strobe
J-10
Extension cable (39 P, 0.3 mm)
J-6082-448-A
J-11
Extension cable (39 P, 0.3 mm)
J-4
J-6082-053-B
For connecting the adjusting remote commander
For adjusting the LCD, EVF block
For extension between the CD-408 board (CN301) and
the SY-080 board (CN101)
For extension between the SY-080 board (CN701, 702)
1-686-180-11
and the FR-194 board (CN301, 302)
Note 1: If the micro processor IC in the adjusting remote
commander is not the new micro processor (UPD7503GC56-12), The pages cannot be switched. In this case,
replace with the new micro processor (8-759-148-35).
J-1
J-2
J-3
J-4
J-5
J-6
J-7
J-8
J-9
J-10
J-11
Fig. 6-1-1
6-3
DSC-F717
1-1-2. Preparations
Note 1: For details of how remove the cabinet and boards, refer
to “2. DISASSEMBLY”.
Note 2: When performing only the adjustments, the lens block
and boards need not be disassemble.
Pattern box
1) Connect the equipment for adjustments according to Fig. 6-16.
2) Connect the Adjusting remote commander to the FR-194 board
CN305 via CPC-12 jig (J-6082-436-A). (See Fig. 6-1-3)
L
Note 3: Setting the “Forced CAMERA mode power ON” Mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 21, set data: 07, and press
the PAUSE button of the adjusting remote commander.
The above procedure will enable the camera power
to be turned on. After completing adjustments, be
sure to exit the “Forced CAMERA mode power ON
Mode”.
Front of the lens
L=About 30 cm
Fig. 6-1-2
Note 4: Exiting the “Forced CAMERA mode power ON Mode”
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 21, set data: 00, and press
the PAUSE button of the adjusting remote commander.
3) Select page: 0, address: 01, and set data: 00.
1-1-3. Discharging of the Flashlight Power Supply
The capacitor which is used as power supply of flashlight is charged
with 200 V to 300 V voltage. Discharge this voltage before starting disassembly in order to protect service engineers from electric
shock during disassembly.
Discharge procedure
1. Remove the FR-194 board, and disconnect the harness from
CN404 on the BT-015 board.
2. Fabricate the short jig as shown in Fig. 6-1-5 locally by yourself. Connect the short jig to the pin 1 and pin 2 of CN404
on the BT-015 board. Allow ten seconds to discharge the voltage.
22
Harness
1
CPC cover
CPC-12 jig
(J-6082-436-A)
FR-194 board
CN305
Fig. 6-1-3
BT
-01
5
1 kΩ/1 W
R:1 kΩ/1 W
(Part code:
1-215-869-11)
Wrap insulating tape.
CN404
Fig. 6-1-4
Fig. 6-1-5
6-4
DSC-F717
CONTROL SWITCH BLOCK
(FZ51050)
LENS BLOCK
Need not
connected
CN703
SY-080
BOARD
CN101
CN702
CN701
CN302
CN303
To
MIC/
SPEAKER
UNIT
(TY-014)
CN301
CD-408 BOARD
Need not connected
To MS SOCKET
CN304 CN309
Extension cable
(J-6082-448-A)
Extension cable
(1-686-180-11)
Must be connected to Flash unit
when performing the “Strobe White
Balance Adjustment”.
DC IN jack
To
CONTROL SWITCH BLOCK
(PW51050)
CN306 CN308
FR-194 BOARD
CN302
CN301
CN001
CN305
CN203
CN704
MANUAL FOCUS BLOCK
(MF51050)
AC IN
AC power
adaptor
CN403
CN404
BT-015
BOARD
Color
monitor Vectorscope
Video
(yellow)
CPC-12 jig
(J-6082-436-A)
CN401
Adjusting
remote
commander
Terminated
75 Ω
CN801
AL-013 BOARD
CN705
Audio
(black)
EVF BLOCK
CN702
PANEL UNIT
CN701
SW-379 BOARD
Fig. 6-1-6
6-5
CN851
CN704
A/V OUT jack
LB-082
BOARD
PD-179 BOARD
BACK LIGHT
DSC-F717
1-1-4. Precautions
1. Setting the Switch
Unless otherwise specified, set the switches as follows and perform adjustments.
1. Mode Dial .......................................... CAMERA
2. FOCUS switch
(FZ51050 block S308) ....................... MANUAL
3. EXPOSURE button
(PW51050 block S404) ..................... 0EV
4. DISPLAY button
(SW-379 board S355) ........................ OSD OFF
5. WHT BAL
(FZ51050 block S304) ....................... AUTO
6. P.EFFECT (Menu display) ................ OFF
7. VIDEO OUT (SET UP setting) ......... NTSC
2. Order of Adjustments
Basically carry out adjustments in the order given.
Color bar chart (Standard picture frame)
Electronic beam scanning frame
C
C=D
D
Yellow
Cyan
Green
White
Magenta
Red
Blue
Blue
Yellow
Cyan
Green
White
Magenta
Red
H
CRT picture frame
V
A B
A=B
B A
Fig. b (monitor TV picture)
Enlargement
Difference in level
Adjust the camera zoom and direction to
obtain the output waveform shown in Fig a
and the monitor TV display shown in Fig. b.
B
A
Fig. 6-1-7
3. Subjects
1) Color bar chart (Standard picture frame).
When performing adjustments using the color bar chart, adjust the picture frame as shown in Fig. 6-1-7. (Standard picture frame)
2) Clear chart (Standard picture frame)
Remove the color bar chart from the pattern box and insert a
clear chart in its place. (Do not perform zoom operations during this time)
3) Chart for flange back adjustment
Join together a piece of white A0 size paper (1189mm × 841
mm) and a piece of black paper to make the chart shown in
Fig. 6-1-8.
White
841 mm
Black
1189 mm
Note: Use a non-reflecting and non-glazing vellum paper. The
size must be A0 or larger and the joint between the white
and black paper must not have any undulations.
Fig. 6-1-8
6-6
DSC-F717
4. Preparing the Flash Adjustment Box
A dark room is required to provide an accurate flash adjustment.
If it is not available, prepare the flash adjustment box as given
below;
1) Provide woody board A, B and C of 15 mm thickness.
Dimensions without brackets are for a box of 1 m in depth.
Dimensions in brackets are for a box of 50 cm in depth.
woody board A (2)
woody board B (2)
woody board C (1)
530 mm
(400 mm)
500 mm
(370 mm)
1000 mm
(700 mm)
1026 mm
(513 mm)
1030 mm
(730 mm)
1000 mm
(700 mm)
1026 mm
(513 mm)
1000 mm
(700 mm)
Fig. 6-1-9
2) Apply black mat paint to one side of woody board A and B.
3) Attach background paper (J-2501-130-A) to woody board C.
4) Assemble so that the black sides and the background paper
side of woody board A, B and C are internal. (Fig 6-1-10)
woody board A
woody board B
woody board A
woody board B
woody board C
Fig. 6-1-10
6-7
DSC-F717
COVER
1-2.
3. A Page table
Note 1: Fixed data-1: Initialized data.
(Refer to “1. Initializing the A, D Page Data”)
Note 2: Fixed data-2: Modified data.
(Refer to “2. Modification of A, D Page Data”)
INITIALIZATION OF A, B, D, E, F, 7, 9 PAGE
DATA
1-2-1. Initialization of A, D Page Data
1. Initializing A, D Page Data
Note: If the A, D page data has been initialized, the following
adjustments need to be performed again.
1) Modification of A, D page data
2) Video system adjustments
3) LCD system adjustments
4) Color electronic viewfinder system adjustment
Adjsuting page
Address Initial value
00 to 4E
Fixed data-1 (Initialized data)
4F
Fixed data-2
50 to 81
A
Fixed data-1 (Initialized data)
82
2D
VCO adj. (NTSC mode) (LCD)
3C
VCO adj. (PAL mode) (LCD)
V-COM adj. (LCD)
Adjsuting Address
00 to FF
83
Adjusting page
D
84
63
Adjusting Address
10 to 7F
85
16
86
87
6B
Order Page Address Data
88
90
1
0
01
01
89
83
2
4
03
11
8A
0A
3
4
00
2D
8B to 91
4
4
01
2D
5
4
02
6
34
VCO adj. (NTSC mode) (EVF)
Check the data changes to “01”.
93
44
VCO adj. (PAL mode) (EVF)
Perform “Modification of
A, D page Data”.
94
7F
Bright adj. (EVF)
95
Fixed data-1 (Initialized data)
2
2
01
Fixed data-1 (Initialized data)
98
94
99
82
9A
25
9B to 9F
A0
White balance adj. (EVF)
Contrast adj. (EVF)
Fixed data-1 (Initialized data)
80
A1 to A7
Composite video level adj.
Fixed data-1 (Initialized data)
A8
Fixed data-2
A9
Fixed data-2
AA to FF
Fixed data-1 (Initialized data)
4. D Page table
Note 1: Fixed data-1: Initialized data.
(Refer to “1. Initializing the A, D Page Data”)
Note 2: Fixed data-2: Modified data.
(Refer to “2. Modification of A, D Page Data”)
Address Initial value
Remark
Processing after Completing Modification of A, D Page Data:
00
Contrast adj. (LCD)
92
Modifying Method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the
camera may not operate.
3) When changing the data, press the PAUSE button of the
adjusting remote commander each time when setting new data
to write the data in the non-volatile memory.
4) Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
2
White balance adj. (LCD)
Fixed data-1 (Initialized data)
96, 97
1
V-COM level adj. (LCD)
Press PAUSE button.
2. Modification of A, D Page Data
If the A, D page data has been initialized, change the data of the
“Fixed data-2” address shown in the following table by manual
input.
Order Page Address Data
D Range adj. (LCD)
Fixed data-1 (Initialized data)
Initializing Method:
Procedure
Remark
10 to 20
Procedure
29
21
29
22 to 7F
Press PAUSE button.
6-8
Fixed data-1 (Initialized data)
00
Test mode
Fixed data-1 (Initialized data)
DSC-F717
3. B Page Table
Note 1: Fixed data-1: Initialized data.
(Refer to “1. Initializing B, E, F, 7, 9 Page Data”)
Note 2: Fixed data-2: Modified data.
(Refer to “2. Modification of B, E, F, 7, 9 Page Data”)
Address Initial value
Remark
1-2-2. Initialization of B, E, F, 7, 9 Page Data
1. Initializing B, E, F, 7, 9 Page Data
Note: If the B, E, F, 7, 9 Page data has been initialized,
“Modification of B, E, F, 7, 9 Page Data” and following
adjustments need to be performed again.
1) Modification of B, E, F, 7, 9 page data
2) Camera system adjustments
Adjusting page
B
Adjusting Address
00 to FF
Adjusting page
E
Adjusting Address
00 to FF
Adjusting page
F
Adjusting Address
00 to FF
Adjusting page
7
Adjusting Address
00 to FF
Adjusting page
9
Adjusting Address
00 to FF
00 to FF
4. E Page Table
Note 1: Fixed data-1: Initialized data.
(Refer to “1. Initializing B, E, F, 7, 9 Page Data”)
Note 2: Fixed data-2: Modified data.
(Refer to “2. Modification of B, E, F, 7, 9 Page Data”)
Address Initial value
Remark
00 to 95
96
97 to FF
Initializing Method:
Order Page Address Data
1
0
01
01
2
6
03
11
3
6
00
2D
4
6
01
2D
5
6
02
Procedure
Press PAUSE button.
Check the data changes to “01”.
Perform “Modification of B,
E, F, 7, 9 page Data”.
6
2. Modification of B, E, F, 7, 9 Page Data
If the B, E, F, 7, 9 Page data has been initialized, change the data
of the “Fixed data-2” address shown in the following tables by
manual input.
Modifying Method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the
camera may not operate.
3) When changing the data, press the PAUSE button of the
adjusting remote commander each time when setting new data
to write the data in the non-volatile memory.
4) Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of B, E, F, 7, 9
Page data
Order Page Address Data
1
2
00
29
2
2
01
29
Fixed data-1 (Initialized data)
Procedure
Press PAUSE button.
6-9
Fixed data-1 (Initialized data)
Fixed data-2
Fixed data-1 (Initialized data)
DSC-F717
5. F Page Table
Note 1: Fixed data-1: Initialized data.
(Refer to “1. Initializing the B, E, F, 7, 9 Page Data”)
Note 2: Fixed data-2: Modified data.
(Refer to “2. Modification of B, E, F, 7, 9 Page Data”)
Address Initial value
Remark
00 to 0F
Address Initial value
Fixed data-1 (Initialized data)
3D
00
FF
10
58
3E
11
FF
3F to 57
12
FF
58
13
FF
14
00
15
16
Fixed data-1 (Initialized data)
59
82
15
90
5B
5B
FF
5C
75
5D
5D
17
Fixed data-1 (Initialized data)
18
22
5E
00
19
48
5F
00
1A
2D
60
00
1B
3A
61
00
1C
13
62
00
1D
00
63
00
1E
00
64
00
1F
00
65
30
20
00
66
FE
21
00
67
6D
22
12
68
68
23
00
69 to 6D
24
20
6E
00
25
20
6F
00
26
23
70
2B
27
44
71
E4
28
0A
72
1F
73
8D
74
2A
29
00
00
2B
00
75
90
2C
00
76
21
2D
00
77
13
2E
00
78
00
2F
00
79
00
30
00
7A
00
31
00
7B
00
32
00
7C
00
33
00
7D
00
34
00
7E
00
35
00
7F
00
36
00
80
00
37
00
81
00
38
00
82
00
39
00
83
00
3A
00
84, 85
3B
00
86
00
3C
00
87
00
6-10
Hall adj.
F No. compensation
Light value adj.
Hall adj.
Fixed data-1 (Initialized data)
2A
Flange back adj.
Flange back adj.
5D
5A
LED Ilumination check.
Remark
Mixed color cancel adj.
AWB 3200K standard data input 1
AWB 3200K standard data input 2
AWB 3200K standard data input 3
Fixed data-1 (Initialized data)
AWB 3200K standard data input 3
DSC-F717
Address Initial value
Remark
Address Initial value
88
1A
BA
10
89
A4
BB
35
8A
30
BC
10
8B
08
BD
35
8C
1A
BE
10
8D
0E
BF
35
8E
32
C0
10
8F
2D
C1
35
90
00
C2
00
91
00
C3
00
92
00
C4
00
93
00
C5
00
94
00
95
00
96
AWB 5800K standard data input 1
C6
00
C7
2E
00
C8
13
97
00
C9
0D
98
00
CA
07
CB
07
CC
80
CD
88
CE
98
CF
90
D0
88
D1
00
D2
00
D3
00
99
00
9A
00
9B
00
9C, 9D
9E
AWB 5800K standard data input 2
AWB 5800K standard data input 3
Fixed data-1 (Initialized data)
00
9F
00
A0
2B
AWB 5800K standard data input 3
A1
40
A2
5D
A3
C0
D4
00
A4
E8
D5
00
A5
FB
D6
00
A6
77
D7
14
A7
86
D8 to DF
A8
0E
E0
00
E1
00
E2
00
A9
01
AA
85
AWB 5800K standard data input 1
Color reproduction adj.
90
E3
00
AC
76
E4
00
AD
86
E5
00
AE
E2
E6
00
AF
FB
E7
00
B0
00
AWB 3200K standard data input 1
E8
00
B1
00
AWB 5800K standard data input 1
E9
00
B2
00
AWB 3200K standard data input 1
EA
00
B3
00
AWB 5800K standard data input 1
EB
00
B4
00
AWB 3200K standard data input 1
EC
00
Fixed data-1 (Initialized data)
ED
00
EE
00
EF
00
B6
28
B7
6E
B8
10
B9
35
Strobe white balance adj.
F0 to FF
Mechanical shutter adj.
6-11
Mechanical shutter adj.
Fixed data-1 (Initialized data)
AB
B5
Remark
Strobe white balance adj.
Fixed data-1 (Initialized data)
DSC-F717
6. 7 Page Table
Note 1: Fixed data-1: Initialized data.
(Refer to “1. Initializing B, E, F, 7, 9 Page Data”)
Note 2: Fixed data-2: Modified data.
(Refer to “2. Modification of B, E, F, 7, 9 Page Data”)
Address Initial value
00 to FF
Remark
Fixed data-1 (Initialized data)
7. 9 Page Table
Note 1: Fixed data-1: Initialized data.
(Refer to “1. Initializing B, E, F, 7, 9 Page Data”)
Note 2: Fixed data-2: Modified data.
(Refer to “2. Modification of B, E, F, 7, 9 Page Data”)
Address Initial value
00 to FF
Remark
Fixed data-1 (Initialized data)
6-12
DSC-F717
COVER
1-3.
VIDEO SYSTEM ADJUSTMENT
1. Composite Video Level Adjustment
Adjust the sync level of the composite video signal output and
check the burst level of the composite video signal output.
Mode
PLAY
Signal
Arbitrary
Measurement Point
Video terminal of A/V OUT jack
(75 Ω terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
A
Adjustment Address
A0
Specified Value
Sync level:
A = 286 ± 5 mV (NTSC mode)
A = 300 ± 5 mV (PAL mode)
Burst level:
B = 286 ± 5 mV (NTSC mode)
B = 300 ± 5 mV (PAL mode)
Adjusting method:
Order Page Address Data
1
0
01
01
2
A
02
13
3
4
F1
04
4
A
A0
5
A
A0
Procedure
Press PAUSE button.
Change the data and set the
sync level (A) to the specified
value.
Press PAUSE button.
Check the burst level (B) to the
specified value.
6
Processing after Completing Adjustments:
Order Page Address Data
1
A
02
00
2
4
F1
00
3
0
01
00
Procedure
Press PAUSE button.
B
A
H
Fig. 6-1-11
6-13
DSC-F717
COVER
1-4.
CAMERA SYSTEM ADJUSTMENTS
After completing the camera system adjustments,
release the data setting:
Before perform the camera system adjustments, check that the
specified values of “VIDEO SYSTEM ADJUSTMENTS” are satisfied.
Note: For “CAMERA SYSTEM ADJUSTMENTS”, perform in
order of item numbers.
Order Page Address Data
1
Data setting during camera system adjustments
Perform the following data setting before the camera system adjustments.
It is not necessary to perform the following data setting everytime
when you perform some items of camera system adjustments continuously unless the power is turned off. Only when the power is
turned off during this adjustments, perform the data setting again,
then continue the adjustments.
Set up setting:
1) VIDEO OUT of SET UP setting............... NTSC (NTSC mode)
(This adjustment must be performed in NTSC mode, so don't
set the SET UP setting to “PAL”)
Data setting method:
Order Page Address Data
Procedure
1
0
01
01
2
A
01
Set the bit value of bit 5 is
“1”, and press PAUSE
button. (Note 1)
3
2
10
Check the bit values of bit3,
bit4 and bit5 are “1”.
(Note 1, 2)
4
A
00
Set the bit value of bit 1 is
“1”, and press PAUSE
button. (Note 1)
5
A
02
Set the bit value of bit 1 is
“1”, and press PAUSE
button. (Note 1)
6
A
0D
Set the bit value of bit 5 is
“0”, and press PAUSE
button. (Note 1)
7
D
21
07
8
6
C1
9
6
6C
01
E
96
00
10
11
Press PAUSE button.
Check the data changes to
“02”.
Wait for 1 second.
Press PAUSE button.
Note 1: For the bit values, refer to “6-2. SERVICE MODE”,
“2-3. 2. Bit value discrimination”.
Note 2: In case of wrong data.
• Select page: 2, address: 00 and set data: 29.
• Select page: 2, address: 01 and set data: 29.
• Select page: 2, address: 0C, set the bit value of bit 1 is
1.
• Select page: 2, address: 04 and set data: 04.
Set the adjusting remote commander to normal LANC,
and the power will be turned, off and on automatically.
Note 3: Repeat the “Data setting method”, if the power was turned
off and on during the “CAMERA SYSTEM ADJUSTMENTS”.
6-14
Procedure
E
96
40
2
6
6C
00
3
D
21
00
4
A
0D
Set the bit value of bit 5 is
“1”, and press PAUSE
button. (Note 1)
5
A
02
Set the bit value of bit 1 is
“0”, and press PAUSE
button. (Note 1)
6
A
00
Set the bit value of bit 1 is
“0”, and press PAUSE
button. (Note 1)
7
A
01
Set the bit value of bit 5 is
“0”, and press PAUSE
button. (Note 1)
8
0
01
00
Press PAUSE button.
Press PAUSE button.
DSC-F717
Picture Frame Setting
How to reset the zoom and focus when they deviated:
Order Page Address Data
Mode
CAMERA
Subject
Color bar chart
(Standard picture frame with the
zoom lens at WIDE end)
Measurement Point
Video terminal of A/V OUT jack
(75 Ω terminated)
6
2C
01
2
6
90
00
3
6
91
00
4
6
92
YL
(Note 2)
6
93
YH
(Note 2)
79
Press PAUSE button.
Measuring Instrument
Oscilloscope and monitor TV
5
Specified Value
A=B, C=D, E=F
6
6
01
7
6
07
8
6
01
Note 1: Displayed data of the page 1 of adjusting remote commander.
1:XX:XX
YL data
YH data
Procedure
1
Check the data changes to
“01”.
00
Press PAUSE button.
Note 2: The data noted down at step 7 of “Setting method”.
Check on the oscilloscope
Switch setting
1) FOCUS ....................................................... AUTO
2) MACRO (Control button) .......................... ON
1. Horizontal period
A=B
C=D
Setting method:
Order Page Address Data
B
Procedure
1
Shoot the color bar chart
with the zoom WIDE end.
2
Enter the output of VIDEO
OUT to the monitor TV, and
move the position as shown
in Fig. 6-1-14.
3
Horizontal width of one color
(B, C) and that of black (A,
D) on the color bar chart
should be same. (See Fig. 61-12)
4
With vertical width of black
(E, F) set in same, the color
bar chart should come to the
center of monitor TV. (See
Fig. 6-1-13)
6
0
7
1
03
D
Fig. 6-1-12
Check that the color bar on
the monitor TV is focused.
5
C
A
2. Vertical period
E=F
E
22
Note down the YH and YL
data. (Note 1)
Processing after Completing Adjustment:
Order Page Address Data
1
0
F
03
V
Procedure
Fig. 6-1-13
00
Check on the monitor TV
Color bar chart picture frame
Fig. 6-1-14
6-15
Monitor TV picture frame
DSC-F717
1.
HALL Adjustment
RadarW
RadarW
Mode
CAMERA
Subject
Not required
Measuring Instrument
Adjusting remote commander
Adjustment Page
F
Adjustment Address
58 to 5D, 68
Note 1: Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Adjusting method:
Order Page Address Data
Procedure
Perform “Data setting during
camera system adjustment”.
(Refer to page 6-14)
1
2
6
94
16
3
6
95
81
4
6
01
6D
5
6
02
6
6
01
Press PAUSE button.
(Note 2)
Check the data changes to
“01”.
00
Press PAUSE button.
Note 2: The adjustment data will be automatically input to page:
F, address: 58 to 5D and 68.
Processing after Completing Adjustment:
Order Page Address Data
1
6
01
00
2
6
94
00
3
6
95
00
4
Procedure
Press PAUSE button.
Release the data setting
performed at step 1.
(Refer to page 6-14)
6-16
DSC-F717
2.
Flange Back Adjustment
(Using the minipattern box) RadarW
The inner focus lens flange back adjustment is carried out automatically. In whichever case, the focus will be deviated during
auto focusing/manual focusing.
Mode
CAMERA
Subject
Siemens star chart with ND filter
for minipattern box (Note 1)
Measurement Point
Adjusting method:
Order Page Address Data
1
Adjustment Page
F
Adjustment Address
18 to 3E
Note 1: Dark Siemens star chart.
Note 2: Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
6
01
13
Press PAUSE button.
3
6
01
27
Press PAUSE button.
(Note 4)
4
6
02
Check the data changes to
“01”.
5
F
3E
Check the data.
00: Normal
01 to FF: Defective
Note 4: The adjustment data will be automatically input to page:
F, address: 18 to 3E.
Processing after Completing Adjustment:
Preparations before adjustments:
1) The minipattern box is installed as shown in the following figure.
Note 3: The attachment lenses are not used.
2) Install the minipattern box so that the distance between it and
the front of lens of camera is less than 3 cm.
3) Make the height of minipattern box and the camera equal.
4) Check the output voltage of the regulated power supply is the
specified voltage ± 0.01 Vdc.
5) Check that the center of Siemens star chart meets the center of
shot image screen with the zoom lens at TELE end and WIDE
end respectively.
Order Page Address Data
1
Specified voltage: The specified voltage varies according to the
minipattern box, so adjustment the power supply output voltage to the specified voltage written on the sheet which is supplied with the minipattern box.
Below 3 cm
Minipattern box
Camera
Camera
table
Regulated power supply
Output voltage : Specified voltage ± 0.01 Vdc
Output current : more than 3.5 A
Red (+)
Black (–)
Yellow (SENS +)
White (SENS –)
2
Check operation on monitor TV
Measuring Instrument
Procedure
Perform “Data setting during
camera system adjustment”.
(Refer to page 6-14)
Need not connected
Black (GND)
Fig. 6-1-15
6-17
6
01
00
Procedure
Press PAUSE button.
2
Release the data setting
performed at step 1.
(Refer to page 6-14)
3
Perform “Flange Back
Check”.
DSC-F717
RadarW
Flange Back Adjustment RadarW
(Using the flange back adjustment chart and
Subject More than 500 m Away)
The inner focus lens flange back adjustment is carried out automatically. In whichever case, the focus will be deviated during
auto focusing/manual focusing.
3.
3-2. Flange Back Adjustment (2)
Perform this adjustment after performing “Flange Back Adjustment (1)”.
Mode
CAMERA
Subject
Subject more than 500 m away
(Subject with clear contrast such
as buildings, etc.)
CAMERA
Measurement Point
Check operation on monitor TV
Flange back adjustment chart
(2.0 m from the front of lens)
(Luminance: 300 to 400 lux)
Measuring Instrument
3-1. Flange Back Adjustment (1)
Mode
Subject
Measurement Point
F
Adjustment Address
18 to 3E
Order Page Address Data
Note 1: Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Preparations before adjustments:
1) Place the Flange back adjustment chart 2.0 m from the front
of the lens.
2) Check that the center of Flange back adjustment chart meets
the center of shot image screen with the zoom lens at TELE
end and WIDE end respectively.
Order Page Address Data
1
2
Perform “Data setting during
camera system adjustment”.
(Refer to page 6-14)
Press PAUSE button.
15
Press PAUSE button.
(Note 2)
3
6
01
4
6
02
Check the data changes to
“01”.
5
F
3E
Check the data.
00: Normal
01 to FF: Defective
01
00
29
01
6
6
02
Check the data changes to
“01”.
7
F
3E
Check the data.
00: Normal
01 to FF: Defective
Order Page Address Data
1
3
Perform “Flange Back
Adjustment (2)”.
6-18
6
01
00
Procedure
Press PAUSE button.
2
Release the data setting
performed at step 2.
(Refer to page 6-14)
3
Perform “Flange Back
Check”.
Press PAUSE button.
2
Press PAUSE button.
(Note 2)
6
Processing after Completing Adjustment:
Procedure
Release the data setting
performed at step 1.
(Refer to page 6-14)
Press PAUSE button.
Place ND filter on the lens so
that the optimum image is
obtain.
5
Processing after Completing Adjustment:
6
13
Note 1: Subject with clear contrast such as building, etc.
Nearby subjects less than 500 m away should not be in
the screen.
Note 2: The adjustment data will be automatically input to page:
F, address: 18 to 3E.
Note 2: The adjustment data will be automatically input to page:
F, address: 18 to 3E.
1
01
Procedure
13
Order Page Address Data
6
4
Perform “Data setting during
camera system adjustment”.
(Refer to page 6-14)
1
Procedure
Set the zoom lens to the
TELE end and expose a
subject that is more than 500
m away. (Note 1)
3
Adjusting method:
01
18 to 3E
Adjusting method:
Adjustment Page
6
F
Adjustment Address
Check operation on monitor TV
Measuring Instrument
2
Adjustment Page
DSC-F717
4.
RadarW
RadarW
Flange Back Check
Processing after Completing Adjustment:
Order Page Address Data
Mode
CAMERA
Subject
Siemens star
(1.0 m from the front of the lens)
(Luminance: 200 to 400 lux)
Measurement Point
Check operation on monitor TV
Measuring Instrument
Specified value
Focused at the TELE end and
WIDE end
6
2C
00
2
6
91
00
3
6
92
00
4
6
93
00
5
B
3D
6
Checking method:
Order Page Address Data
Procedure
1
Place the Siemens star 1.0 m
from the front of the lens.
2
To open the IRIS , decrease
the luminous intensity to the
Siemens star up to a point
before noise appear on the
image.
3
Perform “Data setting during
camera system adjustment”.
(Refer to page 6-14)
4
B
3D
5
B
3D
50
6
6
90
00
7
6
91
04
8
6
92
D0
Note down the data.
9
6
93
5A
10
6
01
79
11
6
07
12
6
2C
01
13
6
01
00
14
1
Press PAUSE button.
(Note 1)
Press PAUSE button.
Check the data changes to
“01”.
Press PAUSE button.
While observe the TV
monitor, change the zoom to
the WIDE end and check that
the lens is focused.
Note 1: How to find the data
Decrease the data of page: B, address: 3D until four sides
of a black frame can be seen on the monitor, then find
the value. The largest value under this condition will be
the setting value. If the value is less than 50, change
monitors.
6-19
Procedure
Set data noted down at step
4, and press PAUSE button.
Release the data setting
performed at step 3.
(Refer to page 6-14)
DSC-F717
5. F No. Compensation RadarW
Compensate the unevenness of the iris meter sensitivity.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Adjustment Page
F
Adjustment Address
5E to 64
6. Mechanical Shutter Adjustment RadarW
Adjust the period which the mechanical shutter is closed, and compensate the exposure.
Note 1: Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Adjustment Page
F
Adjustment Address
B8 to D7
Note 1: Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Adjusting method:
Order Page Address Data
Perform “Picture Frame
setting”.
(Refer to page 6-15)
2
4
Order Page Address Data
Perform “Data setting during
camera system adjustment”.
(Refer to page 6-14)
1
3
Adjusting method:
Procedure
6
6
01
BB
Press PAUSE button.
(Note 2)
Check the data changes to
“01”.
02
Note 2: The adjustment data will be automatically input to page:
F, address: 5E to 64.
1
2
6
01
00
1
2
Perform “Picture Frame
setting”.
(Refer to page 6-15)
AD
Press PAUSE button.
(Note 2)
3
6
01
4
6
02
Check the data changes to
“01”.
5
6
AB
Check the data is “00”.
Note 2: The adjustment data will be automatically input to page:
F, address: B8 to D7.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
Perform “Data setting during
camera system adjustment”.
(Refer to page 6-14)
Procedure
Processing after Completing Adjustment:
Press PAUSE button.
Order Page Address Data
Release the data setting
performed at step 1.
(Refer to page 6-14)
1
2
6-20
6
01
00
Procedure
Press PAUSE button.
Release the data setting
performed at step 1.
(Refer to page 6-14)
DSC-F717
7. Light Value Adjustment
Adjust the standard LV value.
8. Mixed Color Cancel Adjustment RadarW
To perform mixed color cancel adjustment based on data of each
color in color bar.
RadarW
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Mode
CAMERA
Subject
Color bar chart
(Standard picture frame with the
zoom lens at WIDE end)
Measurement Point
Displayed data of page: 1 (Note
2) and page: F, address: 65
Adjustment Page
F
Measuring Instrument
Adjusting remote commander
Adjustment Address
6E and 6F
Note 1: Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Adjustment Page
F
Adjustment Address
65 to 67
Specified Value
AE level 1: 0FE0 to 1020
AE level 2: 37 to 4F
Adjusting method:
Order Page Address Data
Note 1: Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2: The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Displayed data
Adjusting method:
Order Page Address Data
1
3
6
01
4
6
02
5
0
03
6
7
0D
F
12
4
7
12
00
Press PAUSE button.
Perform “Data setting during
camera system adjustment”.
(Refer to page 6-14)
5
6
01
D7
Press PAUSE button.
6
6
01
D5
Press PAUSE button.
(Note 2)
7
6
02
Check the data changes to
“01”.
Processing after Completing Adjustment:
Order Page Address Data
01
00
2
0
03
00
3
1
6
01
2
7
12
3
Processing after Completing Adjustment:
6
Check the data changes to
“01”.
Note 2: The adjustment data will be automatically input to page:
F, address: 6E and 6F.
Note 3: The adjustment data will be automatically input to page:
F, address: 65 to 67.
1
Note down the data.
Press PAUSE button.
(Note 3)
Check that the displayed data
satisfies the AE level 2
specified value.
Order Page Address Data
Perform “Picture Frame
setting”.
(Refer to page 6-15)
7
Check that the displayed data
(Note 2) satisfies the AE
level 1 specified value.
65
2
3
06
1
1
Procedure
Perform “Picture Frame
setting”.
(Refer to page 6-15)
2
Procedure
Perform “Data setting during
camera system adjustment”.
(Refer to page 6-14)
Procedure
Press PAUSE button.
Release the data setting
performed at step 1.
(Refer to page 6-14)
6-21
00
Procedure
Press PAUSE button.
Set the data noted down at
step 3, and press PAUSE
button.
Release the data setting
performed at step 1.
(Refer to page 6-14)
DSC-F717
9.
Auto White Balance 3200K Standard Data Input 1
10. Auto White Balance 3200K Standard Data Input 2
RadarW
RadarW
Adjust the white balance standard data at 3200K.
Adjust the white balance standard data at 3200K.
Mode
CAMERA
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Adjustment Page
F
Adjustment Page
F
Adjustment Address
70 to 79, B0, B2, B4
Adjustment Address
7A to 7F
Note 1: Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2: “Auto White Balance 3200K Standard Data Input 1” is
available only once after the power is turned on. Turn the
power off, then on again if the adjustment is retried.
Note 1: Perform this data input after performing “Auto White
Balance 3200K Standard Data Input 1”.
Note 2: Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 3: “Auto White Balance 3200K Standard Data Input 2” is
available only once after the power is turned on. Turn the
power off, then on again if the adjustment is retried.
Adjusting method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 6-14)
2
Perform “Picture Frame
setting”. (Refer to page 6-15)
3
6
37
6
37
04
3
6
01
0B
4
6
02
B6
03
5
6
01
11
6
6
38
7
6
01
8
6
02
9
6
01
10
6
B6
00
11
6
37
02
12
6
01
0B
Press PAUSE button.
Check the data changes to
“01”.
C1
Press PAUSE button. (Note 3)
Order Page Address Data
Press PAUSE button.
1
2
Press PAUSE button. (Note 3)
Note 3: The adjustment data will be automatically input to page:
F, address: 70 to 79, B0, B2 and B4.
Processing after Completing Adjustment:
Order Page Address Data
1
2
6
01
00
Check the data changes to
“01”.
Processing after Completing Adjustment:
Check the data changes to
“01”.
02
Press PAUSE button. (Note 4)
Note 4: The adjustment data will be automatically input to page:
F, address: 7A to 7F.
Check the data changes to
“01”.
00
Procedure
“Auto White Balance 3200K
Standard Data Input 1” is
completed.
1
2
6
6
Order Page Address Data
01
4
13
Adjusting method:
Procedure
Press PAUSE button.
Perform “Auto White
Balance 3200K Standard
Data Input 2”.
6-22
6
01
00
Procedure
Press PAUSE button.
Perform “Auto White
Balance 3200K Standard
Data Input 3”.
DSC-F717
11. Auto White Balance 3200K Standard Data Input 3
12. Auto White Balance 5800K Standard Data Input 1
RadarW
RadarW
Adjust the white balance standard data at 3200K.
Adjust the white balance standard data at 5800K.
Mode
CAMERA
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Adjustment Page
F
Filter
Adjustment Address
80 to 83, 86, 87
Filter C14 for color temperature
correction
Adjustment Page
F
Adjustment Address
88 to 91, A0 to A3, B1, B3
Note 1: Perform this data input after performing “Auto White
Balance 3200K Standard Data Input 2”.
Note 2: Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 3: “Auto White Balance 3200K Standard Data Input 3” is
available only once after the power is turned on. Turn the
power off, then on again if the adjustment is retried.
Note 1: Perform this data input after performing “Auto White
Balance 3200K Standard Data Input 3”.
Note 2: Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 3: “Auto White Balance 5800K Standard Data Input 1” is
available only once after the power is turned on. Turn the
power off, then on again if the adjustment is retried.
Adjusting method:
Order Page Address Data
Procedure
Adjusting method:
“Auto White Balance 3200K
Standard Data Input 2” is
completed.
1
2
6
37
06
3
6
01
0B
4
6
02
Order Page Address Data
Note 4: The adjustment data will be automatically input to page:
F, address: 80 to 83 and 86 to 87.
Processing after Completing Adjustment:
Order Page Address Data
1
2
6
01
00
1
“Auto White Balance 3200K
Standard Data Input 3” is
completed.
2
Place the C14 filter on the
lens.
Press PAUSE button. (Note 4)
Check the data changes to
“01”.
Procedure
Press PAUSE button.
Perform “Auto White
Balance 5800K Standard
Data Input 1”.
Procedure
3
F
A0
4
F
A1
10
Press PAUSE button.
5
F
A2
5D
Press PAUSE button.
6
F
A3
E0
Press PAUSE button.
7
6
37
07
8
6
B6
03
9
6
01
11
10
6
38
11
6
01
12
6
02
13
6
01
14
6
B6
00
15
6
37
08
16
6
01
A5
17
6
2B
Press PAUSE button.
Press PAUSE button.
Check the data changes to
“01”.
C3
Press PAUSE button. (Note 4)
Check the data changes to
“01”.
00
Press PAUSE button.
Press PAUSE button. (Note 4)
Check the data changes to
“01”.
02
Note 4: The adjustment data will be automatically input to page:
F, address: 88 to 91, A0 to A3, B1 and B3.
Processing after Completing Adjustment:
Order Page Address Data
1
2
6-23
6
01
00
Procedure
Press PAUSE button.
Perform “Auto White
Balance 5800K Standard
Data Input 2”.
DSC-F717
13. Auto White Balance 5800K Standard Data Input 2
14. Auto White Balance 5800K Standard Data Input 3
RadarW
RadarW
Adjust the white balance standard data at 5800K.
Adjust the white balance standard data at 5800K.
Mode
CAMERA
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Filter
Filter C14 for color temperature
correction
Filter
Filter C14 for color temperature
correction
Adjustment Page
F
Adjustment Page
F
Adjustment Address
92 to 97
Adjustment Address
98 to 9B, 9E, 9F
Note 1: Perform this data input after performing “Auto White
Balance 5800K Standard Data Input 1”.
Note 2: Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 3: “Auto White Balance 5800K Standard Data Input 2” is
available only once after the power is turned on. Turn the
power off, then on again if the adjustment is retried.
Note 1: Perform this data input after performing “Auto White
Balance 5800K Standard Data Input 2”.
Note 2: Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 3: “Auto White Balance 5800K Standard Data Input 3” is
available only once after the power is turned on. Turn the
power off, then on again if the adjustment is retried.
Adjusting method:
Adjusting method:
Order Page Address Data
Procedure
Order Page Address Data
“Auto White Balance 5800K
Standard Data Input 1” is
completed.
1
2
6
37
0A
3
6
01
A5
4
6
02
Procedure
“Auto White Balance 5800K
Standard Data Input 2” is
completed.
1
2
6
37
0C
Press PAUSE button. (Note 4)
3
6
01
A5
Check the data changes to
“01”.
4
6
02
Press PAUSE button. (Note 4)
Check the data changes to
“01”.
Note 4: The adjustment data will be automatically input to page:
F, address: 92 to 97.
Note 4: The adjustment data will be automatically input to page:
F, address: 98 to 9B and 9E to 9F.
Processing after Completing Adjustment:
Processing after Completing Adjustment:
Order Page Address Data
Order Page Address Data
1
2
6
01
00
Procedure
Press PAUSE button.
1
Perform “Auto White
Balance 5800K Standard
Data Input 3”.
2
6-24
6
01
00
Procedure
Press PAUSE button.
Perform “Auto White
Balance 5800K Check 1”.
DSC-F717
15. Auto White Balance 5800K Check 1
RadarW
RadarW
Order Page Address Data
Mode
CAMERA
21
0
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
22
1
Filter
Filter C14 for color temperature
correction
23
0
Measurement Point
Displayed data of Page: 1 (Note 3)
24
1
25
0
26
1
27
0
28
1
Measuring Instrument
Specified Value
Note 1: Perform this data input after performing “Auto White
Balance 5800K Standard Data Input 3”.
Note 2: Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 3: The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Displayed data
Order Page Address Data
2
Procedure
“Auto White Balance 5800K
Standard Data Input 3” is
completed.
1
2
6
37
13
3
6
B6
03
4
6
01
11
6
38
6
6
01
7
6
02
8
0
03
9
1
10
0
11
1
12
0
13
1
14
0
15
1
16
6
01
17
6
B6
00
18
6
37
14
19
6
01
3F
6
Press PAUSE button.
Check the data changes to
“01”.
5
20
C3
Press PAUSE button.
Check the data changes to
“01”.
04
Check that the displayed data
(Note 3) satisfied the R ratio
specified value.
05
Check that the displayed data
(Note 3) satisfied the B ratio
specified value.
2C
Check that the R-Y level data
(Note 3) satisfied the
specified value.
2D
Check that the B-Y level data
(Note 3) satisfied the
specified value.
02
03
05
Check that the displayed data
(Note 3) satisfied the B ratio
specified value.
00
03
2E
Check that the R-Y level data
(Note 3) satisfied the
specified value.
03
2F
Check that the B-Y level data
(Note 3) satisfied the
specified value.
Order Page Address Data
1
03
Check that the displayed data
(Note 3) satisfied the R ratio
specified value.
Processing after Completing Adjustment:
Checking method:
03
04
Adjusting remote commander
R ratio: 2910 to 2D10
B ratio: 5BE0 to 5FE0
R-Y level data: 0076 to 0082
B-Y level data: 0078 to 0084
03
03
Procedure
Press PAUSE button.
Press PAUSE button.
Check the data changes to
“01”.
6-25
6
01
00
Procedure
Press PAUSE button.
Perform “Auto White
Balance 5800K Check 2”.
DSC-F717
16. Auto White Balance 5800K Check 2
RadarW
17. Auto White Balance 5800K Check 3
RadarW
RadarW
Mode
CAMERA
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Measurement Point
Displayed data of page: F, address:
94, 95
Measurement Point
Displayed data of page: F, address
9A, 9B
Measuring Instrument
Adjusting remote commander
Measuring Instrument
Adjusting remote commander
Specified Value 1
11 to 4D
Specified Value 1
23 to 9B
Specified Value 2
00 to 1D, DC to FF
Specified Value 2
00 to 30, DA to FF
Note 1: Perform this check after “Auto White Balance 5800K
Check 1” without a break.
Note 2: Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 1: Perform this check after “Auto White Balance 5800K
Check 2” without a break.
Note 2: Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Checking method:
Checking method:
Order Page Address Data
Procedure
Order Page Address Data
Procedure
1
“Auto White Balance 5800K
Check 1” is completed.
1
2
Remove the C14 filter on the
lens.
2
F
9A
Check that the data specified
value 1.
3
F
9B
Check that the data specified
value 2.
3
F
94
Check that the data specified
value 1.
4
F
95
Check that the data specified
value 2.
“Auto White Balance 5800K
Check 2” is completed.
Processing after Completing Adjustment:
Order Page Address Data
Processing after Completing Adjustment:
Order Page Address Data
1
1
Procedure
Perform “Auto White
Balance 5800K Check 3”.
6-26
Procedure
Perform “Auto White
Balance 3200K Check 1”.
DSC-F717
18. Auto White Balance 3200K Check 1
RadarW
RadarW
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Measurement Point
Displayed data of Page: 1 (Note 3)
Measuring Instrument
Adjusting remote commander
Specified Value
R ratio: 3E00 to 4200
B ratio: 3E00 to 4200
R-Y level data: 007E to 0082
B-Y level data: 007E to 0082
Order Page Address Data
Note 1: Perform this check after “Auto White Balance 5800K
Check 3” without a break.
Note 2: Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 3: The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Displayed data
22
1
23
0
24
1
25
0
26
1
27
0
28
1
Check that the displayed data
(Note 3) satisfied the R ratio
specified value.
03
05
Check that the displayed data
(Note 3) satisfied the B ratio
specified value.
03
2E
Check that the R-Y level data
(Note 3) satisfied the
specified value.
03
2F
Check that the B-Y level data
(Note 3) satisfied the
specified value.
Processing after Completing Adjustment:
Order Page Address Data
Checking method:
1
Order Page Address Data
Procedure
2
“Auto White Balance 5800K
Check 3” is completed.
1
2
6
37
0D
3
6
B6
03
4
6
01
11
5
6
38
6
6
01
Press PAUSE button.
Check the data changes to
“01”.
C1
Press PAUSE button.
Check the data changes to
“01”.
7
6
02
8
0
03
9
1
10
0
11
1
12
0
13
1
14
0
15
1
16
6
01
17
6
B6
00
18
6
37
0E
19
6
01
0F
20
6
02
21
0
03
04
Check that the displayed data
(Note 3) satisfied the R ratio
specified value.
03
05
Check that the displayed data
(Note 3) satisfied the B ratio
specified value.
03
2C
Check that the R-Y level data
(Note 3) satisfied the
specified value.
03
2D
Check that the B-Y level data
(Note 3) satisfied the
specified value.
00
Procedure
Press PAUSE button.
Press PAUSE button.
Check the data changes to
“01”.
04
6-27
6
01
00
Procedure
Press PAUSE button.
Perform “Auto White
Balance 3200K Check 2”.
DSC-F717
19. Auto White Balance 3200K Check 2
RadarW
20. Auto White Balance 3200K Check 3
RadarW
RadarW
Mode
CAMERA
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Measurement Point
Displayed data of page: F, address:
7C, 7D
Measurement Point
Displayed data of page: F, address:
82, 83
Measuring Instrument
Adjusting remote commander
Measuring Instrument
Adjusting remote commander
Specified Value 1
00 to 2F, EE to FF
Specified Value 1
00 to 82, E7 to FF
Specified Value 2
00 to 23, F6 to FF
Specified Value 2
00 to 6D, F1 to FF
Note 1: Perform this check after “Auto white Balance 3200K
Check 1” without a break.
Note 2: Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 1: Perform this check after “Auto white Balance 3200K
Check 2” without a break.
Note 2: Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Checking method:
Checking method:
Order Page Address Data
1
Procedure
Order Page Address Data
“Auto White Balance 3200K
Check 1” is completed.
1
Procedure
“Auto White Balance 3200K
Check 2” is completed.
2
F
7C
Check that the data specified
value 1.
2
F
82
Check that the data specified
value 1.
3
F
7D
Check that the data specified
value 2.
3
F
83
Check that the data specified
value 2.
Processing after Completing Adjustment:
Processing after Completing Adjustment:
Order Page Address Data
Order Page Address Data
1
Procedure
Perform “Auto White
Balance 3200K Check 3”.
1
6
37
00
2
0
03
00
3
6-28
Procedure
Release the data setting
performed at step 1 in “Auto
White Balance 3200K
Standard Data Input 1”.
(Refer to page 6-22)
DSC-F717
RadarW
21. Color Reproduction Adjustment RadarW
Adjust the color separation matrix coefficient so that proper color
reproduction is produced.
Mode
CAMERA
Subject
Color bar chart
(Standard picture frame with the
zoom lens at WIDE end)
Measurement Point
Video terminal of A/V OUT jack
(75 Ω terminated)
R-Y
YE
Vectorscope
Adjustment Page
F
Adjustment Address
A4 to AF
Specified Value
All color luminance points
should settle within each color
reproduction frame.
B
Menu setting:
1) VIDEO OUT of SET UP menu
................................ NTSC (NTSC mode)
G
Fig. 6-1-16
Adjusting method:
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 6-14)
2
Perform “Picture Frame
Setting”. (Refer to page 6-15)
6
01
AB
4
6
12
80
5
6
Press PAUSE button.
Wait for 1 second.
6
12
00
7
Wait for 2 seconds.
8
6
37
1F
9
6
01
A9
10
6
02
Press PAUSE button. (Note 4)
Check the data changes to
“01”.
Check the each color luminance point is in each color
reproduction frame.
11
Note 4: The adjustment data will be automatically input to page:
F, address: A4 to AF.
Processing after Completing Adjustment:
Order Page Address Data
1
6
37
00
2
6
01
00
3
CY
Burst position
Note 1: “Auto White Balance 3200K Standard Data Input” and
“Auto White Balance 5800K Standard Data Input” need
to be adjusted beforehand.
Note 2: Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 3: “Color Reproduction Adjustment” is available only once
after the power is turned on. Turn the power off, then on
again if the adjustment is retried.
3
W
B-Y
Measuring Instrument
Order Page Address Data
MG
R
Procedure
Press PAUSE button.
Release the data setting
performed at step 1.
(Refer to page 6-14)
6-29
DSC-F717
22. CCD White Defect Compensation
RadarW
Mode
CAMERA
Subject
Not required
Measurement Point
Displayed data of page: 6,
address: 55
Measuring Instrument
Adjusting remote commander
Note 1: Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2: The“CCD White Defect Compensation” should be made
when the set warms up at certain duration after the power
was turned on, as it is affected with the temperature.
Adjusting method:
Order Page Address Data
Procedure
Perform “Data setting during
camera system adjustment”.
(Refer to page 6-14)
1
2
E
64
Note down the data.
3
E
64
4
E
69
5
E
69
16
6
6
01
8B
1E
Press PAUSE button.
Note down the data.
Press PAUSE button.
Press PAUSE button.
7
6
02
Check the data changes to
“01”.
8
6
55
Check the data.
00 to 7F: Normal
80 to FF: Defective
9
6
01
00
Press PAUSE button.
10
E
64
0F
Press PAUSE button.
11
E
69
60
Press PAUSE button.
12
6
01
87
Press PAUSE button.
13
6
02
Check the data changes to
“01”.
14
6
55
Check the data.
00: Normal
01 to FF: Defective
Processing after Completing Adjustment:
Order Page Address Data
6
01
2
E
64
Set data noted down at step
2, and press PAUSE button.
3
E
69
Set data noted down at step
4, and press PAUSE button.
4
00
Procedure
1
Press PAUSE button.
Release the data setting
performed at step 1.
(Refer to page 6-14)
6-30
DSC-F717
23. CCD Black Defect Compensation
RadarW
Processing after Completing Adjustment:
Order Page Address Data
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Measurement Point
Displayed data of page: 6,
address: 55
Measuring Instrument
Adjusting remote commander
Note 1: Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2: Check that there are no dust, no dirt and reflection of the
clear chart.
Note 3: Any subject other than the clear chart should be in the
screen.
2
E
65
3
E
65
4C
4
6
2C
01
5
6
90
00
6
6
91
03
7
6
92
00
8
6
93
00
Note down the data.
9
6
01
79
10
6
30
08
11
6
07
12
6
01
13
Procedure
Perform “Data setting during
camera system adjustment”.
(Refer to page 6-14)
1
6
Press PAUSE button.
Press PAUSE button.
Check the data changes to
“01”.
8D
Press PAUSE button.
02
Check the data changes to
“01”.
Check the data.
00 to 14 : Normal
15 to FF : Defective
(Note 4)
14
6
55
15
6
01
00
Press PAUSE button.
16
E
65
5A
Press PAUSE button.
17
6
01
89
Press PAUSE button.
18
6
02
Check the data changes to
“01”.
19
6
55
Check the data.
00: Normal
01 to FF: Defective
6
01
2
6
2C
00
3
6
30
00
4
6
91
00
5
E
65
6
Adjusting method:
Order Page Address Data
1
Note 4: If the data is “00” at the check in this adjustment method
order #14, skip the orders from #15 to #19, and go forward to “Processing after Completing Adjustment.
6-31
00
Procedure
Press PAUSE button.
Set data noted down at step
2, and press PAUSE button.
Release the data setting
performed at step 1.
(Refer to page 6-14)
DSC-F717
24. CCD Linearity Check (Monitoring)
Check that CCD output at monitoring keeps being straight even
input is changed.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Measurement Point
Displayed data of Page: 1 (Note 1)
Measuring Instrument
Adjusting remote commander
Specified Value 1
97 to 103 (decimal notation)
Specified Value 2
97 to 105 (decimal notation)
Order Page Address Data
24
1
Procedure
Read displayed data. (Note 1)
25
Get average value of
displayed data of ten times,
and named average value as
DB/GHi.
26
Convert DB/GHi to decimal
notation, and obtain DB/GHi’.
Set data noted down at step
16, and press PAUSE button.
27
B
72
28
6
14
8B
30
0
03
40
31
1
Note 1: The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Displayed data
29
Adjusting method:
32
Get average value of
displayed data of ten times,
and named average value as
DR/GLow.
33
Convert DR/GLow to decimal
notation, and obtain DR/GLow’.
Order Page Address Data
Perform “Data setting during
camera system adjustment”.
(Refer to page 6-14)
2
Perform “Picture Frame
setting”. (Refer to page 6-15)
7
09
04
4
6
C8
26
5
6
13
A8
6
6
14
90
8
0
03
40
9
1
7
0
35
1
13
1
03
Convert DB/GLow to decimal
notation, and obtain DB/GLow’.
38
Calculate D1 by using the
following equation. (decimal
calculation)
D1 = (DR/GHi’ ÷ DR/GRef’) × 100
39
Check that calculated D1
satisfies the specified value
1.
40
Calculate D2 by using the
following equation. (decimal
calculation)
D2 = (DB/GHi’ ÷ DB/GRef’) × 100
41
Check that calculated D2
satisfies the specified value
2.
42
Calculate D3 by using the
following equation. (decimal
calculation)
D3 = (DR/GLow’ ÷ DR/GRef’) × 100
43
Check that calculated D3
satisfies the specified value
1.
Read displayed data. (Note 1)
44
Get average value of
displayed data of ten times,
and named average value as
DR/GHi.
Calculate D4 by using the
following equation. (decimal
calculation)
D4 = (DB/GLow’ ÷ DB/GRef’) × 100
45
Check that calculated D4
satisfies the specified value
1.
41
Read displayed data. (Note 1)
14
Get average value of
displayed data of ten times,
and named average value as
DB/GRef.
15
Convert DB/GRef to decimal
notation, and obtain DB/GRef’.
16
B
72
17
B
72
Note down the data.
50
18
Press PAUSE button.
Wait for 2 seconds.
19
0
20
1
03
40
21
Convert DR/GHi to decimal
notation, and obtain DR/GHi’.
22
0
03
Read displayed data. (Note 1)
37
Convert DR/GRef to decimal
notation, and obtain DR/GRef’.
0
41
36
Get average value of
displayed data of ten times,
and named average value as
DR/GRef.
12
03
Get average value of
displayed data of ten times,
and named average value as
DB/GLow.
Press PAUSE button.
Read displayed data. (Note 1)
11
23
34
Wait for 2 seconds.
10
Read displayed data. (Note 1)
Procedure
1
3
Wait for 2 seconds.
41
6-32
DSC-F717
Processing after Completing Adjustment:
Order Page Address Data
1
6
C8
00
2
0
03
00
3
7
09
00
4
6
13
00
5
6
14
00
6
Procedure
Press PAUSE button.
Release the data setting
performed at step 1.
(Refer to page 6-14)
6-33
DSC-F717
25. CCD Linearity Check (Caputure)
Check that CCD output at caputure keeps being straight even input is changed.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Order Page Address Data
Measurement Point
Displayed data of Page: 1 (Note 1)
Measuring Instrument
Adjusting remote commander
Specified Value
97 to 103 (decimal notation)
7
09
4
6
C8
26
5
6
13
A8
6
04
6
14
90
7
8
Procedure
Perform “Picture Frame
setting”. (Refer to page 6-15)
3
6
01
F9
0
11
1
03
13
Convert DR/GRef to decimal
notation, and obtain DR/GRef’.
15
1
14
8B
Wait for 2 seconds.
6
01
F9
03
38
0
39
1
03
40
Read displayed data. (Note 1)
40
This data is named DR/GLow.
41
Convert DR/GLow to decimal
notation, and obtain DR/GLow’.
42
0
43
1
03
41
Read displayed data. (Note 1)
44
This data is named DB/GLow.
45
Convert DB/GLow to decimal
notation, and obtain DB/GLow’.
46
Calculate D1 by using the
following equation. (decimal
calculation)
D1 = (DR/GHi’ ÷ DR/GRef’) × 100
47
Check that calculated D1
satisfies the specified value.
48
Calculate D2 by using the
following equation. (decimal
calculation)
D2 = (DB/GHi’ ÷ DB/GRef’) × 100
49
Check that calculated D2
satisfies the specified value.
50
Calculate D3 by using the
following equation. (decimal
calculation)
D3 = (DR/GLow’ ÷ DR/GRef’) × 100
51
Check that calculated D3
satisfies the specified value.
52
Calculate D4 by using the
following equation. (decimal
calculation)
D4 = (DB/GLow’ ÷ DB/GRef’) × 100
53
Check that calculated D4
satisfies the specified value.
41
Read displayed data. (Note 1)
16
This data is named DB/GRef.
17
Convert DB/GRef to decimal
notation, and obtain DB/GRef’.
18
6
01
19
B
72
20
B
72
00
Press PAUSE button.
Note down the data.
50
21
Press PAUSE button.
Wait for 2 seconds.
22
6
23
9
24
0
25
1
01
F9
Press PAUSE button.
Processing after Completing Adjustment:
Wait for 3 seconds.
03
Order Page Address Data
40
Read displayed data. (Note 1)
1
6
01
00
2
6
C8
00
26
This data is named DR/GHi.
3
0
03
00
27
Convert DR/GHi to decimal
notation, and obtain DR/GRHi’.
4
7
09
00
5
6
13
00
6
6
14
00
28
0
29
1
30
03
Press PAUSE button.
Wait for 3 seconds.
Read displayed data. (Note 1)
This data is named DR/GRef.
0
6
40
12
14
34
Press PAUSE button.
Wait for 3 seconds.
10
72
Press PAUSE button.
Set data noted down at step
19, and press PAUSE button.
Press PAUSE button.
Wait for 2 seconds.
9
B
00
37
Perform “Data setting during
camera system adjustment”.
(Refer to page 6-14)
2
01
33
36
Adjusting method:
1
6
35
Note 1: The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Displayed data
Order Page Address Data
Convert DB/GHi to decimal
notation, and obtain DB/GHi’.
31
32
Procedure
41
Read displayed data. (Note 1)
This data is named DB/GHi.
7
6-34
Procedure
Press PAUSE button.
Press PAUSE button.
Release the data setting
performed at step 1.
(Refer to page 6-14)
DSC-F717
RadarW
26. Strobe White Balance Adjustment RadarW
Adjust the white balance when the strobe light flashed.
Mode
CAMERA
Subject
Flash adjustment box (Note 3)
Paper which reflection rate is
18% (Note 6)
(50 cm from the front of lens)
Measurement Point
Order Page Address Data
15
6
01
67
16
Displayed data of page: 1 (Note
4) and page: F, address: E8, EA,
EC, EE
Procedure
Press PAUSE button.
Check the flashing.
Check the data changes to
“01”.
17
6
02
18
6
01
00
Press PAUSE button.
19
6
01
67
Press PAUSE button.
20
Check the flashing.
Check the data changes to
“01”.
21
6
02
F
22
6
01
00
Press PAUSE button.
Adjustment Address
B6, B7, E0 to EF
23
6
01
67
Press PAUSE button.
Specified Value
Y level data 1: 03 to 0A
Y level data 2: 03 to 08
R-Y level data:
007A to 0086 (Note 4)
B-Y level data:
007A to 0086 (Note 4)
24
Measuring Instrument
Adjusting remote commander
Adjustment Page
25
Check the flashing.
6
Check the data changes to
“01”.
02
26
6
01
00
Press PAUSE button.
27
6
01
B9
Press PAUSE button. (Note 7)
28
Note 1: Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2: Perform this adjustment in the Flash adjustment box.
Note 3: Refer to “4. Preparing the Flash adjustment box”.
(See page 6-7)
Note 4: The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Displayed data
Note 5: “Strobe White Balance Adjustment” is available only
once after the power is turned on. Turn the power off,
then on again if the adjustment is retried.
Note 6: Background paper (J-2501-130-A).
Check the flashing.
Check the data changes to
“01”.
29
6
02
30
6
01
00
Press PAUSE button.
31
6
01
E7
Press PAUSE button.
32
Check the flashing.
33
6
02
Check the data changes to
“01”.
34
F
EA
EC
EE
Check that the displayed data
satisfies the Y level data 2
specified value.
03
35
Wait for 1 second.
Switch setting:
1) FLASH (Control button) .............. ON
36
0
Adjusting method:
37
1
38
0
39
1
Order Page Address Data
Procedure
Perform “Data setting during
camera system adjustment”.
(Refer to page 6-14)
1
2C
Check that the R-Y level data
(Note 4) satisfies the specified
value.
03
2D
Check that the B-Y level data
(Note 4) satisfies the specified
value.
2
6
2C
01
3
6
90
00
4
6
91
00
5
6
92
FF
Processing after Completing Adjustment:
6
6
93
FF
Order Page Address Data
Note 7: The adjustment data will be automatically input to page:
F, address: B6 to B7 and E0 to EF.
1
6
01
00
Press PAUSE button.
2
6
90
00
Check the data changes to
“01”.
3
6
91
00
4
6
92
00
Press PAUSE button.
5
6
93
00
11
Check the flashing.
6
6
2C
00
12
Check the data changes to
“01”.
7
6
6C
00
8
0
03
00
Check that the displayed data
satisfies the Y level data 1
specified value.
9
7
6
6C
01
8
6
01
79
9
6
07
10
6
01
6
67
02
13
F
E8
14
6
01
00
Press PAUSE button.
6-35
Procedure
Press PAUSE button.
Release the data setting
performed at step 1.
(Refer to page 6-14)
DSC-F717
RadarW
27. LED Illumination Check RadarW
Check a deviation of optical axis between AF illuminator and camera image.
Processing after Completing Adjustment:
Order Page Address Data
1
6
01
00
Procedure
Press PAUSE button.
Mode
CAMERA
Subject
Flash adjustment box (Note 4)
Paper which reflection rate is
18% (Note 5)
(50 cm from the front of lens)
2
F
15
Set data noted down at step 2,
and press PAUSE button.
3
9
62
Set data noted down at step 3,
and press PAUSE button.
Measurement Point
Displayed data of page: F,
address: 13
4
9
83
Set data noted down at step 4,
and press PAUSE button.
Measuring Instrument
Adjusting remote commander
5
Adjustment Page
F
Adjustment Address
10 to 16
Specified Value
Data of page: F, address: 10 is
“00”
Note 1: Do not look directly into AF illumination which has not
been adjusted yet or failed in the adjustment abnormally.
Note 2: Perform checking by making the shooting surface of the
Flash adjustment box perpendicular to the optical axis of
the camera.
Note 3: Perform this checking in the Flash adjustment box.
Restrict external light to enter the Flash adjustment box
as less as possible.
Note 4: Refer to “4. Preparing the Flash adjustment box”.
(See page 6-7)
Note 5: Background paper (J-2501-130-A).
Adjusting method:
Order Page Address Data
Procedure
Perform “Data setting during
camera system adjustment”.
(Refer to page 6-14)
1
2
F
15
Note down the data.
3
9
62
Note down the data.
4
9
83
Note down the data.
5
F
15
80
Press PAUSE button.
6
9
62
06
Press PAUSE button.
7
9
83
50
Press PAUSE button.
8
6
01
AF
Press PAUSE button. (Note 6)
9
6
02
Check the data changes to
“01”.
10
F
13
Check the data.
00: Normal
FF: Defective
Note 6: The adjustment data will be automatically input to page:
F, address: 10 to 16.
6-36
Release the data setting performed at step 1. (Refer to
page 6-14)
DSC-F717
28. AF Illumination Check RadarW
Check a deviation of optical axis between AF illuminator and camera image and defocusing of the pattern.
Adjusting method:
Order Page Address Data
Mode
CAMERA
1
Subject
Flash adjustment box (Note 3)
(1 m from the front of lens)
2
6
Measurement Point
Check operation on monitor TV
3
B
3D
4
B
3D
5
6
6
6
7
Measuring Instrument
Specified Value
All luminance points should
settle within specification frame.
Note 1: Perform checking by making the shooting surface of the
Flash adjustment box perpendicular to the optical axis of
the camera.
Note 2: Perform this checking in the Flash adjustment box.
Restrict external light to enter the Flash adjustment box
as less as possible.
Note 3: Refer to “4. Preparing the Flash adjustment box”.
(See page 6-7)
Switch setting:
1) FOCUS .......................................... AUTO
Preparation
1) Take a reduced or enlarged copy on the clear sheet so that a
rectangular frame of the sheet for auxiliary light is suitable for
the effective image size of the monitor.
2) Stick the copied sheet for auxiliary light on the monitor screen.
Procedure
Perform “Data setting during
camera system adjustment”.
(Refer to page 6-14)
30
06
Note down the data.
50
Press PAUSE button.
2C
01
Press PAUSE button.
90
00
6
91
D0
8
6
92
5A
9
6
93
50
10
6
01
79
Press PAUSE button.
Check the data changes to
“01”.
11
6
07
12
6
01
00
13
6
22
05
14
6
23
0A
Press PAUSE button.
Check that the hologram patterns are all within the specification frame. (None of the hologram patterns are completely
out of the frame.)
15
Processing after Completing Adjustment:
Order Page Address Data
B
3D
2
6
01
00
3
6
22
00
4
6
23
00
5
6
2C
00
6
6
30
00
7
6
92
00
8
6
93
00
9
Fig. 6-1-17
6-37
Set data noted down at step
3, and press PAUSE button.
1
Specification frame
Procedure
Press PAUSE button.
Release the data setting
performed at step 1.
(Refer to page 6-14)
DSC-F717
COVER
1-5.
[Adjusting connector]
Most of the measuring points for adjusting the LCD system are
concentrated in CN305 of the FR-194 board.
Connect the Measuring Instruments via the CPC-12 jig (J-6082436-A).
The following table shows the Pin No. and signal name of CN305.
LCD SYSTEM ADJUSTMENTS
Before perform the LCD system adjustments, check that the specified values of “VIDEO SYSTEM ADJUSTMENTS” are satisfied.
Note 1: Taken an extreme care not to destroy the liquid crystal
display module by static electricity when replacing it.
Note 2: Set the LCD BRIGHTENSS (SET UP setting) to the
NORMAL.
Pin No.
Signal Name
Pin No.
1
BL_L1
12
LANC_OUT
2
N.C.
13
MAKER_RECOG
3
N. C.
14
N.C.
4
REG_GND
15
N.C.
5
N. C.
16
N.C.
6
BL_L2
17
N.C.
7
PANEL_HSY
18
N.C.
8
PANEL_COM
19
EVF_BL
9
PANEL_VG
20
EVF_BL_4.75V
10
CPC_UNREG
21
EVF_VG
11
LANC_IN
22
EVF_VCO
22
1
CPC cover
CPC-12 jig
(J-6082-436-A)
FR-194 board
CN305
Fig. 6-1-18
6-38
Signal Name
DSC-F717
1.
2.
LCD Initial Data Input (1)
Mode
LCD Initial Data Input (2)
PLAY
Mode
PLAY
Signal
Arbitrary
Signal
Arbitrary
Adjustment Page
A
Adjustment Page
B
Adjustment Address
80 to 8F, A3
Adjustment Address
3A to 3F
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: A, and enter the data given in the following table.
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: B, and enter the data given in the following table.
Note: Press the PAUSE button each time the data are set, as the
data are written to non-volatile memory (EEPROM).
Note: Press the PAUSE button each time the data are set, as the
data are written to non-volatile memory (EEPROM).
Address
Data
80
7A
Address
Data
3A
57
81
22
82
2D
VCO Adjustment (NTSC mode)
3B
FE
3C
02
83
3C
VCO Adjustment (PAL mode)
3D
5A
84
85
63
V-COM Adjustment
3E
00
16
D Range Adjustment
3F
01
86
B8
Fixed value
87
6B
V-COM Level Adjustment
88
90
89
83
8A
0A
8B
00
8C
2F
8D
31
8E
80
8F
1F
A3
06
Remark
Fixed value
Remark
Fixed data
Processing after Completing Adjustments:
1) Select page: 0, address: 01, and set data: 00.
White Balance Adjustment
Contrast Adjustment
Fixed value
Processing after Completing Adjustments:
1) Select page: 0, address: 01, and set data: 00.
6-39
DSC-F717
4. D Range Adjustment (PD-179 Board)
Set the D Range of the RGB decoder for driving the LCD to the
specified value.
If deviated, the LCD screen image will be blackish or saturated
(whitish).
3. VCO Adjustment (PD-179 Board)
Set the VCO free-run frequency. If deviated, the LCD screen will
be blurred.
Mode
PLAY
Signal
Arbitrary
Measurement Point
Pin 7 of CN305 on FR-194
board (PANEL_HSY)
Measuring Instrument
Frequency counter
Adjustment Page
A
Adjustment Address
82 (NTSC mode)
83 (PAL mode)
Specified Value
f = 15734 ± 100 Hz (NTSC mode)
f = 15625 ± 100 Hz (PAL mode)
Menu setting:
1) VIDEO OUT of SET UP setting
......................... NTSC (NTSC mode)
(This adjustment must be performed in NTSC mode, so don’t
set the menu setting to “PAL” )
Mode
PLAY
Signal
Arbitrary
Measurement Point
Pin 9 of CN305 on FR-194
board (PANEL_VG)
External trigger: Pin 8 of
CN305 on FR-194 board
(PANEL_COM)
Measuring Instrument
Oscilloscope
Adjustment Page
A
Adjustment Address
85
Specified Value
A = 2.95 ± 0.05 Vp-p
Adjusting method:
Order Page Address Data
Procedure
Adjusting method:
1
0
01
01
Order Page Address Data
2
A
02
13
3
4
F1
03
4
A
85
Change the data and set the
voltage (A) to the specified
value.
5
A
85
Press PAUSE button.
Procedure
1
0
01
01
2
A
02
13
3
4
F1
13
4
A
82
Change the data and set the
frequency (f) to the NTSC
specified value.
5
A
82
Press PAUSE button.
6
4
1D
7
8
A
A
Press PAUSE button.
Processing after Completing Adjustments:
Order Page Address Data
82
Change the data and set the
frequency (f) to the PAL
specified value.
83
83
Press PAUSE button.
1
A
02
00
2
4
F1
00
3
0
01
00
Procedure
Press PAUSE button.
Press PAUSE button.
Pedestal
Processing after Completing Adjustments:
Order Page Address Data
1
A
02
00
2
3
4
F1
00
4
1D
80
4
0
01
00
Procedure
Press PAUSE button.
A
Pedestal
2H
A: Pedestal level difference between 1H period and
previous 1H period.
Fig. 6-1-19
6-40
DSC-F717
5. Contrast Adjustment (PD-179 Board)
Set the level of the VIDEO signal for driving the LCD to the specified value.
If deviated, the LCD screen image will be blackish or saturated
(whitish).
Mode
PLAY
Signal
Arbitrary
Measurement Point
Pin 9 of CN305 on FR-194
board (PANEL_VG)
External trigger: Pin 8 of
CN305 on FR-194 board
(PANEL_COM)
Measuring Instrument
6. V-COM Level Adjustment (PD-179 Board)
Set the common electrode drive signal level of LCD to the specified value.
Mode
PLAY
Signal
Arbitrary
Measurement Point
Pin 8 of CN305 on FR-194
board (PANEL_COM)
Measuring Instrument
Oscilloscope
Adjustment Page
A
Adjustment Address
87
Specified Value
A = 5.42 ± 0.05 Vp-p
Oscilloscope
Adjustment Page
A
Adjusting method:
Adjustment Address
8A
Order Page Address Data
Specified Value
A = 2.65 ± 0.07 Vp-p
Adjusting method:
Order Page Address Data
0
01
01
2
A
02
13
3
4
F1
03
4
A
8A
Change the data and set the
voltage (A) to the specified
value.
5
A
8A
Press PAUSE button.
Order Page Address Data
02
00
2
4
F1
00
3
0
01
00
01
2
A
02
13
3
4
F1
03
4
A
87
Change the data and set the
voltage (A) to the specified
value.
5
A
87
Press PAUSE button.
Press PAUSE button.
Press PAUSE button.
Processing after Completing Adjustments:
Order Page Address Data
Processing after Completing Adjustments:
A
0
Procedure
1
1
01
Procedure
1
1
A
02
00
2
4
F1
00
3
0
01
00
Procedure
Press PAUSE button.
Procedure
Press PAUSE button.
A
10 steps peak
2H
A
Fig. 6-1-21
Pedestal
2H
A: Between the pedestal and 10 steps peak
Fig. 6-1-20
6-41
DSC-F717
7. V-COM Adjustment (PD-179 Board)
Set the DC bias of the common electrode drive signal of LCD to
the specified value.
If deviated, the LCD display will be move, producing flicker and
conspicuous vertical lines.
Mode
PLAY
Signal
Arbitrary
Measurement Point
Check on LCD screen
8. White Balance Adjustment (PD-179 Board)
Correct the white balance.
If deviated, the LCD screen color cannot be reproduced.
A
Adjustment Address
84
Specified Value
The brightness difference
between the section-A and
section-B is minimum
PLAY
Signal
Arbitrary
Measurement Point
Check on LCD screen
Measuring Instrument
Measuring Instrument
Adjustment Page
Mode
Adjustment Page
A
Adjustment Address
88, 89
Specified Value
LCD screen must not be colored
Note 1: Check the white balance only when replacing the following parts. If necessary, adjust them.
1. LCD panel
2. Light induction plate
3. IC801
Note: Perform “D Range Adjustment”, “Contrast Adjustment”
and “V-COM Level Adjustment” before this adjustment.
Adjusting method:
Adjusting method:
Order Page Address Data
Order Page Address Data
1
0
01
01
2
A
02
13
3
4
F1
82
Procedure
Press PAUSE button.
4
A
84
Change the data so that
brightness of the section A
and section B is equal.
5
A
84
Press PAUSE button.
1
0
01
01
2
A
02
13
3
4
F1
02
A
88
89
90
83
4
Processing after Completing Adjustments:
Order Page Address Data
1
A
02
00
2
4
F1
00
3
0
01
00
Procedure
Press PAUSE button.
Press PAUSE button.
Press PAUSE button.
(Initial value)
Check that the LCD screen is
not colored. If not colored,
proceed to “Processing after
Completing Adjustments”.
5
6
Procedure
A
Change the data so that the
LCD screen is not colored.
(Note 2)
88
89
Note 2: To write in the non-volatile memory (EEPROM), press
the PAUSE button each time to set the data.
Processing after Completing Adjustments:
Order Page Address Data
B
A
A
B
B
A
A
B
Fig. 6-1-22
6-42
1
A
02
00
2
4
F1
00
3
0
01
00
Procedure
Press PAUSE button.
DSC-F717
COVER
1-6.
[Adjusting connector]
Most of the measuring points for adjusting the viewfinder system
are concentrated in CN305 of the FR-194 board.
Connect the Measuring Instruments via the CPC-12 jig (J-6082436-A).
The following table shows the Pin No. and signal name of CN305.
COLOR ELECTRONIC VIEWFINDER SYSTEM
ADJUSTMENTS
Before perform the color electronic viewfinder system adjustments,
check that the specified values of “VIDEO SYSTEM ADJUSTMENTS” are satisfied.
Note 1: Taken an extreme care not to destroy the liquid crystal
display module by static electricity when replacing it.
Note 2: Set the EVF BACKLIGHT (SET UP setting) to the NORMAL.
Pin No.
Signal Name
Pin No.
1
BL_L1
12
LANC_OUT
2
N.C.
13
MAKER_RECOG
3
N. C.
14
N.C.
4
REG_GND
15
N.C.
5
N. C.
16
N.C.
6
BL_L2
17
N.C.
7
PANEL_HSY
18
N.C.
8
PANEL_COM
19
EVF_BL
9
PANEL_VG
20
EVF_BL_4.75V
10
CPC_UNREG
21
EVF_VG
11
LANC_IN
22
EVF_VCO
22
1
CPC cover
CPC-12 jig
(J-6082-436-A)
FR-194 board
CN305
Fig. 6-1-23
6-43
Signal Name
DSC-F717
1.
EVF Initial Data Input
2. VCO Adjustment (PD-179 Board)
Set the VCO free-run frequency. If deviated, the EVF screen will
be blurred.
Mode
PLAY
Signal
Arbitrary
Adjustment Page
A
Adjustment Address
90 to 9D, A2
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: A, and enter the data given in the following table.
Note: Press the PAUSE button each time the data are set, as the
data are written to non-volatile memory (EEPROM).
Address
Data
90
30
91
72
92
34
VCO Adjustment (NTSC mode)
93
44
VCO Adjustment (PAL mode)
Mode
PLAY
Signal
Arbitrary
Measurement Point
Pin ws of CN305 on FR-194
board (EVF_VCO)
Measuring Instrument
Frequency counter
Adjustment Page
A
Adjustment Address
92 (NTSC mode)
93 (PAL mode)
Specified Value
f = 15734 ± 100 Hz (NTSC mode)
f = 15625 ± 100 Hz (PAL mode)
Remark
Menu setting:
1) VIDEO OUT of SET UP setting
......................... NTSC (NTSC mode)
(This adjustment must be performed in NTSC mode, so don’t
set the menu setting to “PAL” )
Fixed value
94
28
Fixed value
95
7F
Bright Adjustment
Adjusting method:
96
08
80
Fixed value
Order Page Address Data
97
98
94
99
82
9A
25
9B
1D
9C
2B
9D
00
A2
30
White Balance Adjustment
Contrast Adjustment
1
0
01
01
2
A
02
23
Press PAUSE button.
3
4
F1
13
(NTSC mode)
4
4
1D
82
(PAL mode)
5
A
92
6
A
92
Press PAUSE button.
Change the data and set the
frequency (f) to the NTSC
specified value.
Fixed value
Processing after Completing Adjustments:
1) Select page: 0, address: 01, and set data: 00.
Procedure
7
A
93
Change the data and set the
frequency (f) to the PAL
specified value.
8
A
93
Press PAUSE button.
Processing after Completing Adjustments:
Order Page Address Data
1
6-44
A
Procedure
02
00
Press PAUSE button.
2
4
F1
00
(NTSC mode)
3
4
1D
80
(PAL mode)
4
0
01
00
DSC-F717
3. Bright Adjustment (PD-179 Board)
Set the D Range of the RGB decoder for driving the LCD to the
specified value.
If deviated, the EVF screen image will be blackish or saturated
(whitish).
4. Contrast Adjustment (PD-179 Board)
Set the level of the VIDEO signal for driving the LCD to the specified value.
If deviated, the EVF screen image will be blackish or saturated
(whitish).
Mode
PLAY
Mode
PLAY
Signal
Arbitrary
Signal
Arbitrary
Measurement Point
Pin wa of CN305 on FR-194
board (EVF_VG)
Measurement Point
Pin wa of CN305 on FR-194
board (EVF_VG)
Measuring Instrument
Oscilloscope
Measuring Instrument
Oscilloscope
Adjustment Page
A
Adjustment Page
A
Adjustment Address
95
Adjustment Address
9A
Specified Value
A = 7.00 ± 0.10 Vp-p
Specified Value
A = 1.75 ± 0.10 Vp-p
Adjusting method:
Adjusting method:
Order Page Address Data
1
0
01
01
2
A
02
23
3
4
F1
03
Procedure
Order Page Address Data
Press PAUSE button.
4
A
95
Change the data and set the
voltage (A) to the specified
value.
5
A
95
Press PAUSE button.
1
0
01
01
2
A
02
23
03
Procedure
Press PAUSE button.
3
4
F1
4
A
9A
Change the data and set the
voltage (A) to the specified
value.
5
A
9A
Press PAUSE button.
Processing after Completing Adjustments:
Processing after Completing Adjustments:
Order Page Address Data
Order Page Address Data
1
A
02
00
2
4
F1
3
0
01
Procedure
Press PAUSE button.
1
A
02
00
00
2
4
F1
00
00
3
0
01
00
Procedure
Press PAUSE button.
Pedestal
10 steps peak
A
A
Pedestal
Pedestal
2H
2H
A: Between the reversed waveform pedestal and non-reversed
waveform pedestal
A: Between the pedestal and 10 steps peak
Fig. 6-1-25
Fig. 6-1-24
6-45
DSC-F717
5. White Balance Adjustment (PD-179 Board)
Correct the white balance.
If deviated, the EVF screen color cannot be reproduced.
Mode
PLAY
Signal
Arbitrary
Measurement Point
Check on EVF screen
Measuring Instrument
Adjustment Page
A
Adjustment Address
98, 99
Specified Value
EVF screen must not be colored
Adjusting method:
Order Page Address Data
1
0
01
01
2
A
02
23
3
4
F1
02
A
98
99
94
82
4
Press PAUSE button.
Press PAUSE button.
(Initial value)
Check that the EVF screen is
not colored. If not colored,
proceed to “Processing after
Completing Adjustments”.
5
6
Procedure
A
Change the data so that the
EVF screen is not colored.
(Note)
98
99
Note: To write in the non-volatile memory (EEPROM), press the
PAUSE button each time to set the data.
Processing after Completing Adjustments:
Order Page Address Data
1
A
02
00
2
4
F1
00
3
0
01
00
Procedure
Press PAUSE button.
6-46
DSC-F717
COVER
6-2. SERVICE MODE
2-1.
• Changing the address
The address increases when the FF (M) button is pressed,
and decreases when the REW (m) button is pressed. There
are altogether 256 addresses, from 00 to FF.
• Changing the data (Data setting)
The data increases when the PLAY (N) button is pressed,
and decreases when the STOP (x) button is pressed. There
are altogether 256 data, from 00 to FF.
• Writing the adjustment data
The PAUSE button must be pressed to write the adjustment
data in the nonvolatile memory. (The new adjustment data
will not be recorded in the nonvolatile memory if this step is
not performed)
ADJUSTING REMOTE COMMANDER
The adjusting remote commander is used for changing the calculation coefficient in signal processing, EVR data, etc. The adjusting remote commander performs bi-directional communication
with the unit using the remote commander signal line (LANC).
The resultant data of this bi-directional communication is written
in the non-volatile memory.
1. Used the Adjusting Remote Commander
1) Connect the adjusting remote commander to CN305 on the
FR-194 board via CPC-12 jig (J-6082-436-A).
2) Adjust the HOLD switch of the adjusting remote commander
to “HOLD” (SERVICE position).
3) Turn on the power with the POWER switch of the unit.
If it has been properly connected, the LCD on the adjusting remote commander will display as shown in Fig. 6-2-1.
2.
Precautions upon Using the Adjusting Remote
Commander
Mishandling of the adjusting remote commander may erase the
correct adjustment data at times. To prevent this, it is recommended
that all adjustment data be noted down before beginning adjustments and new adjustment data after each adjustment.
0 : 00 : 00
Page
Data Address
Fig. 6-2-1
4) Operate the adjusting remote commander as follows.
• Changing the page
The page increases when the EDIT SEARCH + button is
pressed, and decreases when the EDIT SEARCH – button is
pressed. There are altogether 16 pages, from 0 to F.
Hexadecimal
notation
LCD Display
Decimal notation
conversion value
0 1 2 3 4 5 6 7 8 9 A B C D E F
01 2 3 4 5 6 7 8 9 A b c d E F
0 1 2 3 4 5 6 7 8 9 10 11 1213 1415
Table 6-2-1
6-47
DSC-F717
COVER
2-2.
DATA PROCESS
The calculation of the adjusting remote commander display data
(hexadecimal notation) are required for obtaining the adjustment
data of some adjustment items. In this case, after converting the
hexadecimal notation to decimal notation, calculate and convert
the result to hexadecimal notation, and use it as the adjustment
data. Table 6-2-2. indicates the hexadecimal notation- the decimal notation, calculation table.
Hexadecimal nontation-Decimal notation
The lower digits of the
0
1
2
3
4
5
6
7
8
9
A
B
C
2
↓
D
E
F
hexadecimal notation
The upper digits of the
(A) (b) (c) (d) (E) (F)
hexadecimal notation
1→
0
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
1
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
2
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
3
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
4
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
5
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
6
96
97
98
99 100 101 102 103 104 105 106 107 108 109 110 111
7
112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127
8
128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143
9
144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159
A (A)
160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175
B (b)
176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191
C (c)
192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207
D (d)
208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223
E (E)
224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239
F (F)
240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255
Note : ( ) indicate the adjusting remote control unit display.
(Example) In the case that the adjusting remote control unit display are BD (bd).
As the upper digit of the hexadecimal notation is B (b), and the lower digit is D (d), the intersection “189” of
the1 and 2 in the above table is the decimal notation to be calculated.
Table 6-2-2
6-48
DSC-F717
COVER
2-3.
1.
SERVICE MODE
Display on the
Setting the Test Mode
Page D
Adjusting
remote
commander
Address 21
Data
Function
Bit values
bit3
or
bit7
bit2
or
bit6
bit1
or
bit5
bit0
or
bit4
0
0
0
0
0
1
0
0
0
1
00
Normal
2
0
0
1
0
05
Forced MOVIE mode power ON
3
0
0
1
1
07
Forced CAMERA mode power ON
4
0
1
0
0
08
Forced PLAY mode power ON
5
0
1
0
1
09
Forced SET UP mode power ON
6
0
1
1
0
7
0
1
1
1
8
1
0
0
0
• Before setting the data, select page: 0, address: 01, and set data:
01.
• For page D, the data set is recorded in the non-volatile memory
by pressing the PAUSE button of the adjusting remote commander. In this case, take note that the test mode will not be
exited even when the main power is turned off.
• After completing adjustments/repairs, be sure to return the data
of this address to “00”, and press the PAUSE button of the adjusting remote commander.
Select page: 0, address: 01, and set data: 00.
A
B
2. Bit Value Discrimination
Bit values must be discriminated using the display data of the adjusting remote commander for following items. Use the table below to discriminate if the bit value is “1” or “0”.
1
0
0
1
1
0
1
0
B (b)
1
0
1
1
C (c)
1
1
0
0
D (d)
1
1
0
1
E (E)
1
1
1
0
F (F)
1
1
1
1
Example: If “8E” is displayed on the adjusting remote commander, the bit values for bit7 to bit4 are shown in the
A column, and the bit values for bit3 to bit0 are shown
in the B column.
Display on the adjustilng remote commander
0 : 00 : 00
Address
Page
9
A (A)
bit3 to bit0 discrimination
bit7 to bit4 discrimination
6-49
DSC-F717
3.
6.
Mode Dial Check (1)
Page 2
Page 2
Address 90
Data
Function
Bit
Address 80
Function
When bit value=1 When bit value=0
00 to 14
S
0
POWER SW
OFF
ON
15 to 3D
A
1
PLAY (Mode Dial)
others
PLAY
3E to 67
M
2
68 to A8
SCN
3
SHUTTER SW
PW51050 block
S401
OFF
ON
4
XSHUTTER LOCK SW
PW51050 block
OFF
S401
ON
5
MEMORY STICK IN SW
OUT
(MS Socket)
IN
A9 to D0
MOVIE
D1 to FF
CAMERA
Using method:
1) Select page: 2, address: 90.
2) By discriminating the bit value of dispaly data, the state of the
switches can be discriminated.
4. Mode Dial Check (2)
Page 2
Address 80, 81
Function
When bit
value=1
When bit
value=0
Bit
80
1
PLAY
others
PLAY
81
4
SET UP
others
SET UP
Using method:
1) Select page: 2, address: 80 and 81.
2) By discriminating the bit value of dispaly data, the state of the
switches can be discriminated.
Jog Dial Check
Page 2
Address 81
Using method:
1) Set the mode dial to any position other than “SET UP’”.
2) Select page: 2, address: 81.
3) By discriminating the upper digit of the data, the rotation of
the control dial can be discriminated.
Jog dial
(PW51050 block (S403))
When rotated upward.
When rotated downward.
(
(
)
)
Using method:
1) Select page: 2, address: 80.
2) By discriminating the bit value of dispaly data, the state of the
switches can be discriminated.
Address
5.
Switch Check (1)
Upper digit of the data
...→ 3 → B → F → 7 → 3 →...
...→ 3 → 7 → F → B → 3 →...
6-50
DSC-F717
7. Switch Check (2)
Page 2
Address 91 to 95
Using method:
1) Select page: 2, addresses: 91 to 95.
2) By discriminating the dispaly data, the pressed key can be
discriminated.
Address
Data
00 to 14
15 to 3D
3E to 67
68 to A8
A9 to D0
D1 to FF
91
(KEY AD0)
(IC102 tg)
CONTROL DOWN
(SW-379 board)
(S353)
CONTROL UP
(SW-379 board)
(S353)
MENU
(SW-379 board)
(S352)
INDEX
(SW-379 board)
(S351)
FINEDER
(SW-379 board)
(S354)
LCD
(SW-379 board)
(S354)
92
(KEY AD1)
(IC102 th)
CONTROL RIGHT CONTROL LEFT CONTROL SET
(SW-379 board)
(SW-379 board)
(SW-379 board)
(S353)
(S353)
(S353)
DISPLAY
(SW-379 board)
(S355)
93
(KEY AD2)
(IC102 tj)
ONE-PUSH
FOCUS
FOCUS
WHT BAL
AE LOCK
SPOT METER
WHITE BALANCE
MANUAL
AUTO
(FZ51050 block) (FZ51050 block)
(FZ51050 block)
(FZ51050 block)
(FZ51050 block) (FZ51050 block)
(S301)
(S302)
(S304)
(S303)
(S308)
(S308)
94
(KEY AD3)
(IC102 tk)
+/–
JOG DIAL
(EXPOSURE)
EXECUTE
(PW51050 block) (PW51050 block)
(S404)
(S406)
95
(KEY AD4)
(IC102 tl)
ZOOM T
ZOOM T
ZOOM W
ZOOM W
(Fast)
(Slow)
(Fast)
(Slow)
(FZ51050 block) (FZ51050 block) (FZ51050 block) (FZ51050 block)
(S306)
(S306)
(S307)
(S307)
NIGHT FRAMING
ON
(TY-014 block)
(S301)
No key input
NIGHT SHOT
ON
(TY-014 block)
(S301)
NIGHT SHOT
NIGHT FRAMING
OFF
(TY-014 block)
(S301)
No key input
8. LED Check
Page 2
Address 04
Data 02
Using method:
1) Select page: 2, address: 04, set data: 02, and press PAUSE
button.
2) Check that all LED are lit.
(SELF TIMER/REC, POWER, CHG, ACCESS LED)
3) Select page: 2, address: 04, set data: 00, and press PAUSE
button.
9. Self Diagnosis Code
Display Code
C:32:ss
Countermeasure
Cause
Caution Display During Error
Turn the power off and on again.
Trouble with hardware.
SYSTEM ERROR
Format the “Memory Stick”.
Unformatted “Memory Stick” is inserted.
FORMAT ERROR
Insert a new “Memory Stick”.
“Memory Stick” is broken.
MEMORY STICK ERROR
E:61:ss
Checking of lens drive circuit.
When failed in the focus and zoom
initialization.
E:91:ss
Checking of flash unit or replacement
of flash unit.
Abnormality when flash is being
charged.
C:13:ss
6-51
—
DSC-F717
Take a reduced or enlarged copy on the clear sheet so that a
rectangular frame of the SHEET FOR AUXILIARY LIGHT
is suitable for the effective image size of the monitor.
6-52
✄
DSC-F717
AF ILLUMINATION CHECK
DSC-F717
FOR CAMERA COLOR REPRODUCTION ADJUSTMENT
Take a copy of CAMERA COLOR
REPRODUCTION FRAME with a
clear sheet for use.
For NTSC mode
R-Y
MG
R
YE
W
B-Y
B
G
✄
✄
CY
DSC-F717
6-53 E
Reverse
992999451.pdf
Revision History
Ver.
Date
1.0
2002.09
History
Official Release
Contents
—
S.M. Rev.
issued
—
Download PDF