advertisement
NEC Express5800/R110h-1
System Configuration Guide
Introduction
This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and proper configuration of your NEC Express5800 server.
May 17, 2016
Revision 2.1
NEC Corporation
SYSTEM CONFIGURATION GUIDE
–
NEC Express5800/R110h-1
Contents
NEC Corporation Revision 2.1
– May, 2016
2
SYSTEM CONFIGURATION GUIDE
–
NEC Express5800/R110h-1
Technical Specification
Key Features
High performance with the latest Intel® Xeon® processor E3-1200 v5 product family
Up to 64 GB of high speed DDR4-2133 memory
High energy efficiency with intelligent fan control, power capping feature and 80 PLUS® Platinum or
Gold power supply
Full manageability by integrated EXPRESSSCOPE Engine 3
Specification
2.5-inch Drive Model
(1/2)
Model
Part Number
Processor Type
Chipset
Memory
Clock Speed
Number of Processor
Cache
Cores and Threads
Type
Standard Capacity
Maximum Capacity
Internal Storage Standard Capacity
Maximum Capacity
Expansion Slots
Hot Plug
Optical Disk Drive
Optical Drive Bays
Disk Drive Bays
Video
Interfaces
Disk Controller
RAID
Controller (VRAM)
Resolution / Color
R110h-1
N8100-2337F
Intel® Pentium®
Processor G4400
Intel® Xeon®
Processor E3-1220 v5
3.00 GHz
Intel® Xeon®
Processor E3-1230 v5
3.40 GHz 3.30 GHz
1
3 MB
2C / 2T
8 MB
4C / 4T
Intel® C236 Chipset
DDR4-2133 ECC Unbuffered DIMM
0 GB
64 GB (4 x 16 GB)
0 GB
SATA HDD: 16 TB (8 x 2 TB)
SAS HDD : 14.4 TB (8 x 1.8 TB)
SATA SSD 12.8 TB (8 x 1.6 TB)
SAS SSD 3.2 TB (8 x 400 GB)
SATA : 6 Gb/s (Integrated)
SATA/SAS : 6/12 Gb/s (Optional)
SATA : RAID 0/1/10 (Standard
1
)
SATA/SAS : RAID 0/1/5/6/10/50/60 (Optional)
Supported
4C / 8T
Optional
1
8
Total: 3 slots available
1 PCIe 3.0 x16 (x16 connector)
1 PCIe 3.0 x4 (x8 connector)
1 PCIe 3.0 x4 (x8 connector) dedicated RAID slot
Integrated in Server Management Controller (32MB)
1600 x 1200 / 16.7M
2
1 VGA (15-pin mini D-sub,1 rear)
1 to 2 Serial (9-pin mini D-sub, RS232-C, 1 to 2 rear)
6 USB 3.0 (2 front, 4 rear) (plus 1 internal USB 3.0)
2 1000BASE-T LAN connector (RJ-45, 2 rear)
NEC Corporation Revision 2.1
– May, 2016
3
SYSTEM CONFIGURATION GUIDE
–
NEC Express5800/R110h-1
Model R110h-1
Interfaces (Continued)
1 1000BASE-T LAN connector for management (RJ-45, 1 rear)
Server Management
EXPRESSSCOPE Engine 3
Redundant Fan
Optional, non-hot plug
Power Supply
2 500 Watt 80 PLUS® Gold certified Hot plug PSU
100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz
Power
Consumption
(Max. Config, Idling)
117 VA
/ 116 Watt
125 VA
/ 124 Watt
(Max. Config,
Operating)
286 VA
/ 284 Watt
324 VA
/ 322 Watt
356 VA
/ 353 Watt
Acoustic Noise
(Sound Pressure
Level)
3
Minimum Config.
Maximum Config.
Dimensions (W x D x H )
36 dB
38 dB
49 dB
49 dB
444.0 x 615.2 x 43.6 mm / 17.5 x 24.2 x 1.7 in (1U)
Weight (Minimum / Maximum)
10 kg / 17.5 kg, 22.05 lbs. / 38.58 lbs.
Temperature, Relative Humidity
(non-condensing)
Operating: 5° to 40° C / 41° to 104° F (Standard) or 5° to 45° C / 41° to 113° F (Optional), 20 to 80%
Non-Operating: -10° to 55° C / 14° to 131° F, 20 to 80%
Regulatory and Safety
FCC, c-UL, CE, CB, RoHS, WEEE, BSMI, CCC
Operating Systems and Virtualization
Software
Microsoft® Windows Server® 2008 R2 Standard
Microsoft® Windows Server® 2008 R2 Enterprise
Microsoft® Windows Server® 2012 Standard
Microsoft® Windows Server® 2012 Datacenter
Microsoft® Windows Server® 2012 R2 Standard
Microsoft® Windows Server® 2012 R2 Datacenter
Red Hat Enterprise Linux 6.7 or later (x86_64)
4
Red Hat Enterprise Linux 7.2 or later
4
VMware ESXi 5.5 Update 3
5
VMware ESXi 6.0 Update 1
5
1
Embedded SATA RAID controller is supported only on limited operating systems.
2
Maximum resolution available via EXPRESSSCOPE Engine 3 remote console is 1280 x 1024 / 65K colors.
3
Noise emission was measured in accordance with ISO 7779, at 25°C. The actual value may vary by the operating environment.
4
For Linux support, contact your sales representative or go to the NEC website at: http://www.nec.com/en/global/prod/express/linux/index.html
5
Supported on Xeon processor systems only.
NEC Corporation Revision 2.1
– May, 2016
4
SYSTEM CONFIGURATION GUIDE
–
NEC Express5800/R110h-1
(2/2)
Model
Part Number
Processor Type
Chipset
Clock Speed
Number of Processor
Cache
Cores and Threads
Memory Type
Standard Capacity
Maximum Capacity
Internal Storage Standard Capacity
Maximum Capacity
Expansion Slots
Hot Plug
Optical Disk Drive
Optical Drive Bays
Disk Drive Bays
Video
Interfaces
Server Management
Redundant Fan
Power Supply
Disk Controller
RAID
Controller (VRAM)
Resolution / Color
Power
Consumption
(Max. Config, Idling)
(Max. Config,
Operating)
Acoustic Noise
(Sound Pressure
Level)
3
Minimum Config.
Maximum Config.
Dimensions (W x D x H )
R110h-1
N8100-2337F
Intel® Xeon®
Processor E3-1240L v5
Intel® Xeon®
Processor E3-1260L v5
2.10 GHz 2.90 GHz
Intel® Xeon®
Processor E3-1270 v5
3.60 GHz
1
8 MB
4C / 8T
Intel® C236 Chipset
DDR4-2133 ECC Unbuffered DIMM
0 GB 0 GB 0 GB
64 GB (4 x 16 GB) 64 GB (4 x 16 GB) 64 GB (4 x 16 GB)
0 GB
SATA HDD: 16 TB (8 x 2 TB)
SAS HDD : 14.4 TB (8 x 1.8 TB)
SATA SSD 12.8 TB (8 x 1.6 TB)
SAS SSD 3.2 TB (8 x 400 GB)
SATA : 6 Gb/s (Integrated)
SATA/SAS : 6/12 Gb/s (Optional)
SATA : RAID 0/1/10 (Standard
1
)
SATA/SAS : RAID 0/1/5/6/10/50/60 (Optional)
Supported
Optional
1
8
Total: 3 slots available
1 PCIe 3.0 x16 (x16 connector)
1 PCIe 3.0 x4 (x8 connector)
1 PCIe 3.0 x4 (x8 connector) dedicated RAID slot
Integrated in Server Management Controller (32MB)
1600 x 1200 / 16.7M
2
1 VGA (15-pin mini D-sub,1 rear)
1 to 2 Serial (9-pin mini D-sub, RS232-C, 1 to 2 rear)
6 USB 3.0 (2 front, 4 rear) (plus 1 internal USB 3.0)
2 1000BASE-T LAN connector (RJ-45, 2 rear)
1 1000BASE-T LAN connector for management (RJ-45, 1 rear)
EXPRESSSCOPE Engine 3
Optional, non-hot plug
2 500 Watt 80 PLUS® Gold certified Hot plug PSU
100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz
116 VA
/ 115 Watt
274 VA
/ 272 Watt
49 dB
49 dB
118 VA
/117 Watt
306 VA
/ 303 Watt
126VA
/ 125Watt
358VA
/ 356Watt
444.0 x 615.2 x 43.6 mm / 17.5 x 24.2 x 1.7 in (1U)
NEC Corporation Revision 2.1
– May, 2016
5
SYSTEM CONFIGURATION GUIDE
–
NEC Express5800/R110h-1
Model R110h-1
Weight (Minimum / Maximum)
10 kg / 17.5 kg, 22.05 lbs. / 38.58 lbs.
Temperature, Relative Humidity
(non-condensing)
Operating: 5° to 40° C / 41° to 104° F (Standard) or 5° to 45° C / 41° to 113° F (Optional), 20 to 80%
Non-Operating: -10° to 55° C / 14° to 131° F, 20 to 80%
Regulatory and Safety
FCC, c-UL, CE, CB, RoHS, WEEE, BSMI, CCC
Operating Systems and Virtualization
Software
Microsoft® Windows Server® 2008 R2 Standard
Microsoft® Windows Server® 2008 R2 Enterprise
Microsoft® Windows Server® 2012 Standard
Microsoft® Windows Server® 2012 Datacenter
Microsoft® Windows Server® 2012 R2 Standard
Microsoft® Windows Server® 2012 R2 Datacenter
Red Hat Enterprise Linux 6.7 or later (x86_64)
4
Red Hat Enterprise Linux 7.2 or later
4
VMware ESXi 5.5 Update 3
VMware ESXi 6.0 Update 1
1
Embedded SATA RAID controller is supported only on limited operating systems.
2
Maximum resolution available via EXPRESSSCOPE Engine 3 remote console is 1280 x 1024 / 65K colors.
3
Noise emission was measured in accordance with ISO 7779, at 25°C. The actual value may vary by the operating environment.
4
For Linux support, contact our sales representative or go to the NEC website at: http://www.nec.com/en/global/prod/express/linux/index.html
3.5-inch Drive Model
(1/2)
Model
Part Number
Processor Type
Chipset
Memory
Clock Speed
Number of Processor
Cache
Cores and Threads
Type
Standard Capacity
Maximum Capacity
Internal Storage Standard Capacity
Maximum Capacity
Disk Controller
RAID
Hot Plug
Optical Disk Drive
Optical Drive Bays
Disk Drive Bays
NEC Corporation Revision 2.1
– May, 2016
R110h-1
N8100-2334F, N8100-2335F
Intel® Pentium®
Processor G4400
Intel® Xeon®
Processor E3-1220 v5
3.30 GHz
1
3 MB
2C / 2T
3.00 GHz
8 MB
4C / 4T
Intel® C236 Chipset
DDR4-2133 ECC Unbuffered DIMM
Intel® Xeon®
Processor E3-1230 v5
3.40 GHz
4C / 8T
0 GB 0 GB 0 GB
64 GB (4 x 16 GB) 64 GB (4 x 16 GB) 64 GB (4 x 16 GB)
0 GB
SATA : 24 TB (4 x 6 TB)
SATA : 6Gb/s (Integrated)
SATA : RAID 0/1/10 (Standard
1
), RAID 5/6 (Optional)
Supported
Optional
1
4
6
SYSTEM CONFIGURATION GUIDE
–
NEC Express5800/R110h-1
Model R110h-1
Expansion Slots
Total: 3 slots available
1 PCIe 3.0 x16 (x16 connector)
1 PCIe 3.0 x4 (x8 connector)
1 PCIe 3.0 x4 (x8 connector) dedicated RAID slot
Video Controller (VRAM)
Resolution / Color
Integrated in Server Management Controller (32MB)
1600 x 1200 / 16.7M
2
Interfaces
1 VGA (15-pin mini D-sub,1 rear)
1 to 2 Serial (9-pin mini D-sub, RS232-C, 1 to 2 rear)
6 USB 3.0 (2 front, 4 rear) (plus 1 internal USB 3.0)
2 1000BASE-T LAN connector (RJ-45, 2 rear)
1 1000BASE-T LAN connector for management (RJ-45, 1 rear)
Server Management
EXPRESSSCOPE Engine 3
Redundant Fan
Optional, non-hot plug
Power Supply
1 400 Watt 80 PLUS® Platinum certified non-Hot plug PSU
2 500 Watt 80 PLUS® Gold certified Hot plug PSU
100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz
Power
Consumption
(Max. Config, Idling)
116VA
/ 115 Watt
(Max. Config,
Operating)
268VA
/ 266Watt
307VA
/ 305Watt
338VA
/ 336Watt
Acoustic Noise
(Sound Pressure
Level)
3
Minimum Config.
Maximum Config.
Dimensions (W x D x H )
36 dB
38 dB
49 dB
49 dB
444.0 x 615.2 x 43.6 mm / 17.5 x 24.2 x 1.7 in (1U)
Weight (Minimum / Maximum)
10 kg / 17.5 kg, 22.05 lbs. / 38.58 lbs.
Temperature, Relative Humidity
(non-condensing)
Operating: 5° to 40° C / 41° to 104° F (Standard) or 5° to 45° C / 41° to 113° F (Optional), 20 to 80%
Non-Operating: -10° to 55° C / 14° to 131° F, 20 to 80%
Regulatory and Safety
FCC, c-UL, CE, CB, RoHS, WEEE, BSMI, CCC
Operating Systems and Virtualization
Software
Microsoft® Windows Server® 2008 R2 Standard
Microsoft® Windows Server® 2008 R2 Enterprise
Microsoft® Windows Server® 2012 Standard
Microsoft® Windows Server® 2012 Datacenter
Microsoft® Windows Server® 2012 R2 Standard
Microsoft® Windows Server® 2012 R2 Datacenter
Red Hat Enterprise Linux 6.7 or later (x86_64)
4
Red Hat Enterprise Linux 7.2 or later
4
VMware ESXi 5.5 Update 3
5
VMware ESXi 6.0 Update 1
5
1
Embedded SATA RAID controller is supported only on limited operating systems.
2
Maximum resolution available via EXPRESSSCOPE Engine 3 remote console is 1280 x 1024 / 65K colors.
3
Noise emission was measured in accordance with ISO 7779, at 25°C. The actual value may vary by the operating environment.
4
For Linux support, contact our sales representative or go to the NEC website at: http://www.nec.com/en/global/prod/express/linux/index.html
5
Supported on Xeon processor systems only.
NEC Corporation Revision 2.1
– May, 2016
7
SYSTEM CONFIGURATION GUIDE
–
NEC Express5800/R110h-1
(2/2)
Model
Part Number
Processor
Chipset
Memory
Clock Speed
Number of Processor
Cache
Cores and Threads
Type
Standard Capacity
Maximum Capacity
Internal Storage Standard Capacity
Maximum Capacity
Disk Controller
RAID
Hot Plug
Optical Disk Drive
Optical Drive Bays
Disk Drive Bays
Expansion Slots
Video
Interfaces
Server Management
Redundant Fan
Power Supply
Type
Controller (VRAM)
Resolution / Color
Power
Consumption
(Max. Config, Idling)
(Max. Config,
Operating)
Acoustic Noise
(Sound Pressure
Level)
3
Minimum Config.
Maximum Config.
Dimensions (W x D x H )
Weight (Minimum / Maximum)
Temperature, Relative Humidity
(non-condensing)
R110h-1
N8100-2334F, N8100-2335F
Intel® Xeon®
Processor E3-1240L v5
Intel® Xeon®
Processor E3-1260L v5
2.10 GHz
1
2.90 GHz
8 MB
4C / 8T
Intel® C236 Chipset
DDR4-2133 ECC Unbuffered DIMM
Intel® Xeon®
Processor E3-1270 v5
3.60 GHz
0 GB 0 GB 0 GB
64 GB (4 x 16 GB) 64 GB (4 x 16 GB) 64 GB (4 x 16 GB)
0 GB
SATA : 24 TB (4 x 6 TB)
SATA : 6Gb/s (Integrated)
SATA : RAID 0/1/10 (Standard
1
), RAID 5/6 (Optional)
Supported
Optional
1
4
Total: 3 slots available
1 PCIe 3.0 x16 (x16 connector)
1 PCIe 3.0 x4 (x8 connector)
1 PCIe 3.0 x4 (x8 connector) dedicated RAID slot
Integrated in Server Management Controller (32MB)
1600 x 1200 / 16.7M
2
1 VGA (15-pin mini D-sub,1 rear)
1 to 2 Serial (9-pin mini D-sub, RS232-C, 1 to 2 rear)
6 USB 3.0 (2 front, 4 rear) (plus 1 internal USB 3.0)
2 1000BASE-T LAN connector (RJ-45, 2 rear)
1 1000BASE-T LAN connector for management (RJ-45, 1 rear)
EXPRESSSCOPE Engine 3
Optional, non-hot plug
1 400 Watt 80 PLUS® Platinum certified non-Hot plug PSU
2 500 Watt 80 PLUS® Gold certified Hot plug PSU
100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz
115VA
/ 114Watt
114VA
/ 114Watt
115VA
/ 114Watt
259VA
/ 257Watt
49 dB
290VA
/ 288Watt
341VA
/ 338Watt
49 dB
444.0 x 615.2 x 43.6 mm / 17.5 x 24.2 x 1.7 in (1U)
10 kg / 17.5 kg, 22.05 lbs. / 38.58 lbs.
Operating: 5° to 40° C / 41° to 104° F (Standard) or 5° to 45° C / 41° to 113° F (Optional), 20 to 80%
Non-Operating: -10° to 55° C / 14° to 131° F, 20 to 80%
NEC Corporation Revision 2.1
– May, 2016
8
SYSTEM CONFIGURATION GUIDE
–
NEC Express5800/R110h-1
Model R110h-1
Regulatory and Safety
FCC, c-UL, CE, CB, RoHS, WEEE, BSMI, CCC
Operating Systems and Virtualization
Software
Microsoft® Windows Server® 2008 R2 Standard
Microsoft® Windows Server® 2008 R2 Enterprise
Microsoft® Windows Server® 2012 Standard
Microsoft® Windows Server® 2012 Datacenter
Microsoft® Windows Server® 2012 R2 Standard
Microsoft® Windows Server® 2012 R2 Datacenter
Red Hat Enterprise Linux 6.7 or later (x86_64)
4
Red Hat Enterprise Linux 7.2 or later
4
VMware ESXi 5.5 Update 3
VMware ESXi 6.0 Update 1
1
Embedded SATA RAID controller is supported only on limited operating systems.
2
Maximum resolution available via EXPRESSSCOPE Engine 3 remote console is 1280 x 1024 / 65K colors.
3
Noise emission was measured in accordance with ISO 7779, at 25°C. The actual value may vary by the operating environment.
4
For Linux support, contact our sales representative or go to the NEC website at: http://www.nec.com/en/global/prod/express/linux/index.html
NEC Corporation Revision 2.1
– May, 2016
9
SYSTEM CONFIGURATION GUIDE
–
NEC Express5800/R110h-1
External Views
Front and Rear Views
Front View for 2.5-inch Drive Model
C D
E F G H I J K L M N
B
Front View for 3.5-inch Drive Model
C D
E F G H I J K L M N
B
Legend
A.
Drive Bays
B.
Optical Drive Bay
C.
USB Connector
D.
USB Connector
E.
Power Button / Power LED
F.
UID LED Button
G.
Reset Button
NEC Corporation
H.
Dump (NMI) Switch
I.
BMC Reset Button
J.
System Status LED 1
K.
System Status LED 2
L.
Power Capping LED
M.
Data LAN 1 Activity LED
N.
Data LAN 2 Activity LED
Revision 2.1
– May, 2016
A
A
10
SYSTEM CONFIGURATION GUIDE
–
NEC Express5800/R110h-1
Rear View for Non-redundant PSU Configuration
C D E
H
I
A
F
G
J
K L
Rear View for Redundant PSU Configuration
D
D
E
H I
A
NEC Corporation
C C
Legend
A.
PCI Slot 1B
B.
PCI Slot 1C
C.
AC Inlet
D.
Power Unit
E.
Serial Port Connector
F.
VGA Connector
F G J K L
G.
Power LED
H.
Data LAN 1 Connector
I.
Data LAN 2 Connector
J.
USB 3.0 Connectors
K.
Management LAN Connector
L.
UID LED / Button
Revision 2.1
– May, 2016
B
B
11
SYSTEM CONFIGURATION GUIDE
–
NEC Express5800/R110h-1
Dimensions (mm)
With non-Hot plug PSU
43.6 mm
With Hot plug PSU
NEC Corporation Revision 2.1
– May, 2016
12
SYSTEM CONFIGURATION GUIDE
–
NEC Express5800/R110h-1
Configuration Diagram
2.5-inch Drive Model
Legend: Standard Components
3.5-inch Drive Model (Non-redundant PSU)
Mandatory components
NEC Corporation
Legend: Standard Components Mandatory components
Revision 2.1
– May, 2016
13
SYSTEM CONFIGURATION GUIDE
–
NEC Express5800/R110h-1
3.5-inch Drive Model (Redundant PSU)
Legend:
Expansion Slots
Standard Components Mandatory components
PCI 1B PCI 1C
PCI 1A
Legend
#1A
#1B
#1C
PCIe 3.0 (x4) x4 lanes, x8 connector, for a dedicated RAID controller
PCIe 3.0 (x16) x16 lanes, x16 connector, Low profile, up to 173 mm length
PCIe 3.0 (x4) x4 lanes, x8 connector, Low profile, up to 173 mm length
NEC Corporation Revision 2.1
– May, 2016
14
SYSTEM CONFIGURATION GUIDE
–
NEC Express5800/R110h-1
Server Configuration
1 Base Models
Product Name / Description
NEC Express5800/R110h-1
No CPU, no RAM, no 3.5-inch HDD, no Cooling FAN, no ODD
Including:
3.5-inch Drive Cage, 1x 400 Watt non-hot plug power supply, Front bezel
NEC Express5800/R110h-1
No CPU, no RAM, no 3.5-inch HDD, no Cooling FAN, no ODD
Including:
3.5-inch Drive Cage, 2 x 500 Watt hot plug power supply, Front bezel
NEC Express5800/R110h-1
No CPU, no RAM, no 2.5-inch HDD, no Cooling FAN, no ODD
Including:
2.5-inch Drive Cage, 2 x 500 Watt hot plug power supply, Front bezel,
Part Number
N8100-2334F
N8100-2335F
N8100-2337F
NOTE:
The base model must be ordered with a processor kit, a memory kit, a cooling fan kit, and internal hard drive cable
For Windows Server 2008 R2 installation, EXPRESSBUILDER DVD is required.
2 Processor
Available sockets: 1
Category Product Name / Description
Processors
Required
Pentium G4400 Processor Kit
Intel® Pentium ® Processor G4400 (3.30 GHz, 2C/2T, 3 MB)
Xeon E3-1220 v5 Processor Kit
Intel® Xeon ® Processor E3-1220 v5 (3.00 GHz, 4C/4T, 8 MB)
Xeon E3-1230 v5 Processor Kit
Intel® Xeon ® Processor E3-1230 v5 (3.40 GHz, 4C/8T, 8 MB)
Xeon E3-1240L v5 Processor Kit
Intel® Xeon ® Processor E3-1240L v5 (2.10 GHz, 4C/8T, 8 MB)
Xeon E3-1260L v5 Processor Kit
Intel® Xeon ® Processor E3-1260L v5 (2.90 GHz, 4C/8T, 8 MB)
Xeon E3-1270 v5 Processor Kit
Intel® Xeon ® Processor E3-1270 v5 (3.60 GHz, 4C/8T, 8 MB)
NOTE:
The processor kit must be ordered with the base model.
VMware ESXi is not supported on Pentium processor systems.
Part Number
N8101-939F
N8101-941F
N8101-942F
N8101-943F
N8101-944F
N8101-945F
NEC Corporation Revision 2.1
– May, 2016
15
SYSTEM CONFIGURATION GUIDE
–
NEC Express5800/R110h-1
3 Memory
Available slots: 4
Product Name / Description
4GB DDR4-2133 UNB Memory Kit
1 x 4GB Unbuffered ECC DIMM, DDR4-2133
8GB DDR4-2133 UNB Memory Kit
1 x 8GB Unbuffered ECC DIMM, DDR4-2133
16GB DDR4-2133 UNB Memory Kit
1 x 16GB Unbuffered ECC DIMM, DDR4-2133
Part Number
N8102-656F
N8102-657F
N8102-658F
NOTE:
Minimum one memory kit must be installed.
It is recommended to install memory kits in pairs of two identical DIMMs for dual-channel symmetric memory configurations to increase memory transfer speed.
At least 5 GB of memory is required for
VMware ESXi™ 5.5 and VMware ESXi™ 6.0
Maximum Available Memory
See the table below for the maximum memory size that you can actually use on your system.
The maximum available memory is less than the maximum physical memory supported by your system because some chipsets require PCI resource space of about 750MB. PCI resource requirements vary depending on the type and the number of PCI cards you are using.
Maximum Memory Size Supported by Operating Systems Maximum Available Memory
Microsoft Windows Server 2008 R2 Standard
1
Microsoft Windows Server 2008 R2 Enterprise
1
Microsoft Windows Server 2012 Standard
1
Microsoft Windows Server 2012 Datacenter
1
Microsoft Windows Server 2012 R2 Standard
1
Microsoft Windows Server 2012 R2 Datacenter
1
32 GB
2 TB
4 TB
32 GB
64 GB
64 GB
Red Hat Enterprise Linux 6 (x86_64)
Red Hat Enterprise Linux 7
VMware ESXi 5.5
2
VMware ESXi 6.0
3
6 TB
4 TB
6 TB
64 GB
64 GB
64 GB
1
The maximum available memory size of Hyper-V systems are below:
- Windows Server 2008 R2 Standard : 32 GB
- Windows Server 2008 R2 Enterprise : 1TB
- Windows Server 2012, Windows Server 2012 R2 : 4 TB
2
Up to 1TB of main memory is available to each virtual machine.
3
Up to 4TB of main memory is available to each virtual machine.
NEC Corporation Revision 2.1
– May, 2016
16
SYSTEM CONFIGURATION GUIDE
–
NEC Express5800/R110h-1
4 Internal Hard Disk Drives
4.1 RAID Configuration
Refer to the section in accordance with your disk form factor and RAID configuration.
4.1.1 2.5-inch Drive
Slot 0 Slot 1
Slot 2
Slot 3
Slot 4
Slot 5
Slot 6
Slot 7
Operating System Supported RAID configuration
Windows Server 2008 R2
VMware ESXi 5.5
VMware ESXi 6
KVM in Red Hat Enterprise
Linux 6 (x86_64)
Windows Server 2012
Windows Server 2012 R2
Red Hat Enterprise Linux 6
(x86_64) without KVM
Red Hat Enterprise Linux 7
RAID and Cache
Non-RAID (Embedded SATA)
RAID 0/1/10 No Cache
RAID 0/1/10 1GB Cache
RAID 5/6/50/60 1GB Cache
RAID 5/6/50/60 2GB Cache
Non-RAID (Embedded SATA)
RAID 0/1 (Embedded SATA RAID)
RAID 0/1/10 No Cache
RAID 0/1/10 1GB Cache
RAID 5/6/50/60 1GB Cache
RAID 5/6/50/60 2GB Cache
Non-RAID (Embedded SATA)
RAID 0/1/10 No Cache
RAID 0/1/10 1GB Cache
RAID 5/6/50/60 1GB Cache
RAID 5/6/50/60 2GB Cache
Section
Supported
HDD/SSD
NOTE:
Up to four drives can be installed when you choose the Embedded SATA non-RAID controller.
All drives within a RAID array should be of the same type, capacity and rotation speed.
Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs SAS SSDs,
SATA SSD (ME), and SATA SSD (VE) can be mixed.
Mix configurations of 4Kn sector HDDs and 512n sector HDDs are not supported.
To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process.
NEC Corporation Revision 2.1
– May, 2016
17
SYSTEM CONFIGURATION GUIDE
–
NEC Express5800/R110h-1
4.1.2 3.5-inch Drive
Slot 0 Slot 1 Slot 2 Slot 3
Operating System Supported RAID configuration
Windows Server 2008 R2
VMware ESXi 5.5
VMware ESXi 6
KVM in Red Hat Enterprise
Linux 6 (x86_64)
Windows Server 2012
Windows Server 2012 R2
Red Hat Enterprise Linux 6
(x86_64) without KVM
Red Hat Enterprise Linux 7
RAID and Cache Section
Non-RAID (Embedded SATA)
RAID 0/1/10 No Cache
RAID 0/1/10 1GB Cache
RAID 5/6/50/60 1GB Cache
RAID 5/6/50/60 2GB Cache
Non-RAID (Embedded SATA)
RAID 0/1 (Embedded SATA RAID)
RAID 0/1/10 No Cache
RAID 0/1/10 1GB Cache
RAID 5/6/50/60 1GB Cache
RAID 5/6/50/60 2GB Cache
Non-RAID (Embedded SATA)
RAID 0/1/10 No Cache
RAID 0/1/10 1GB Cache
RAID 5/6/50/60 1GB Cache
RAID 5/6/50/60 2GB Cache
NOTE:
All hard drives within a RAID array should be of the same capacity.
Supported
HDD/SSD
NEC Corporation Revision 2.1
– May, 2016
18
SYSTEM CONFIGURATION GUIDE
–
NEC Express5800/R110h-1
4.2 Required Components for RAID Configuration
4.2.1 Embedded SATA non-RAID Controller for 2.5-inch Drives
Category Product Name / Description Part Number
Storage Controller
Cable
Drive Cage
Embedded SATA Controller
4 x 6Gb/s SATA
Internal SAS/SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD, 1 set
2.5-inch Drive Cage
8 x 2.5-inch Hot-plug hard drive bays
(Standard)
(Standard)
(Standard)
NOTE:
Hot plug insertion/removal is not supported with the embedded SATA non-RAID controller.
4.2.2 Embedded SATA RAID Controller for 2.5-inch Drives
Category Product Name / Description Part Number
Storage Controller
Cable
Drive Cage
Embedded SATA Controller
4x 6Gb/s SATA, RAID 0/1/10 capable
Internal SAS/SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD, 1 set
2.5-inch Drive Cage
8 x 2.5-inch Hot-plug hard drive bays
(Standard)
(Standard)
(Standard)
NOTE
Embedded SATA RAID controller is supported only on limited OS. For more details, please see
Support Matrix for PCI Cards and Embedded Controllers.
All hard drives within a RAID array should be of the same capacity.
4.2.3 RAID 0/1 Controller without Cache for 2.5-inch Drives
Category Product Name / Description Part Number
Storage Controller
Required
Cable
Drive Cage
RAID Controller (RAID 0/1)
Avago(LSI) MegaRAID SAS 9341-8i
RAID 0/1/10, non-cache, Int. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA
6Gb/s
Internal SAS/SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD, 1 set
Internal SAS/SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD, 1 set, for 5th - 8th hard drives
2.5-inch Drive Cage
8 x 2.5-inch hot plug drive bays
N8103-188
(Standard)
K410-348(00)
(Standard)
NOTE:
Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs SAS SSDs,
SATA SSD (ME), and SATA SSD (VE) can be mixed.
All drives within a RAID array should be of the same type, capacity and rotation speed.
NEC Corporation Revision 2.1
– May, 2016
19
SYSTEM CONFIGURATION GUIDE
–
NEC Express5800/R110h-1
4.2.4 RAID 0/1 Controller with 1 GB Cache for 2.5-inch Drives
Category Product Name / Description Part Number
Storage Controller
Required
Flash Backup
Recommended
Cable
Drive Cage
RAID Controller (1GB, RAID 0/1)
Avago(LSI) MegaRAID SAS 9362-8i
RAID 0/1/10, 1GB, Int. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA 6Gb/s
Flash Backup Unit
for Avago(LSI) MegaRAID SAS 9362-8i
650mm Cable for Flash Backup Unit included
Internal SAS/SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD, 1 set
Internal SAS/SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD, 1 set, for 5th - 8th hard drives
2.5-inch Drive Cage
8 x 2.5-inch hot plug drive bays
N8103-176
N8103-181
(Standard)
K410-348(00)
(Standard)
NOTE:
Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs SAS SSDs,
SATA SSD (ME), and SATA SSD (VE) can be mixed.
All drives within a RAID array should be of the same type, capacity and rotation speed.
4.2.5 RAID 5/6 Controller with 1 GB Cache for 2.5-inch Drives
Category Product Name / Description Part Number
Storage Controller
Required
Flash Backup
Recommended
Cable
Drive Cage
RAID Controller (1GB, RAID 0/1/5/6)
Avago(LSI) MegaRAID SAS 9362-8i
RAID0/1/5/6/10/50/60, 1GB, Int. 8, PCIe 3.0 x8, SAS 12Gb/s,
SATA 6Gb/s
Flash Backup Unit
for Avago(LSI) MegaRAID SAS 9362-8i
650mm Cable for Flash Backup Unit included
Internal SAS/SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD, 1 set
Internal SAS/SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD, 1 set, for 5th - 8th hard drives
2.5-inch Drive Cage
8 x 2.5-inch hot plug drive bays
N8103-177
N8103-181
(Standard)
K410-348(00)
(Standard)
NOTE:
Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs SAS SSDs,
SATA SSD (ME), and SATA SSD (VE) can be mixed.
All drives within a RAID array should be of the same type, capacity and rotation speed.
To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process.
NEC Corporation Revision 2.1
– May, 2016
20
SYSTEM CONFIGURATION GUIDE
–
NEC Express5800/R110h-1
4.2.6 RAID 5/6 Controller with 2 GB Cache for 2.5-inch Drives
Category Product Name / Description Part Number
Storage Controller
Required
Flash Backup
Recommended
Cable
Drive Cage
RAID Controller (2GB, RAID 0/1/5/6)
Avago(LSI) MegaRAID SAS 9362-8i
RAID0/1/5/6/10/50/60, 2GB, Int. 8, PCIe 3.0 x8, SAS 12Gb/s,
SATA 6Gb/s
Flash Backup Unit
for Avago(LSI) MegaRAID SAS 9362-8i
650mm Cable for Flash Backup Unit included
Internal SAS/SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD, 1 set
Internal SAS/SATA Cable
1 x Mini SAS HD to 1 x Mini SAS HD, 1 set, for 5th - 8th hard drives
2.5-inch Drive Cage
8 x 2.5-inch hot plug drive bays
N8103-178
N8103-181
(Standard)
K410-348(00)
(Standard)
NOTE:
Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs SAS SSDs,
SATA SSD (ME), and SATA SSD (VE) can be mixed.
All drives within a RAID array should be of the same type, capacity and rotation speed.
To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process.
4.2.7 Embedded SATA non-RAID Controller for 3.5-inch Drives
Category Product Name / Description Part Number
Storage Controller
Cable
Drive Cage
Embedded SATA Controller
4 x 6Gb/s SATA
Internal SAS/SATA Cable
1 x Mini SAS HD to 4 x Single SATA, 1 set
3.5-inch Drive Cage
4 x 3.5-inch Hot-plug hard drive bays
(Standard)
(Standard)
(Standard)
NOTE
Hot plug insertion/removal is not supported with the embedded SATA non-RAID controller.
4.2.8 Embedded SATA RAID Controller for 3.5-inch Drives
Category Product Name / Description Part Number
Storage Controller
Cable
Drive Cage
Embedded SATA Controller
4x 6Gb/s SATA, RAID 0/1/10 capable
Internal SAS/SATA Cable
1 x Mini SAS HD to 4 x Single SATA, 1 set
3.5-inch Drive Cage
4 x 3.5-inch Hot-plug hard drive bays
(Standard)
(Standard)
(Standard)
NOTE:
Embedded SATA RAID controller is supported only on limited OS. For more details, please see
Support Matrix for PCI Cards and Embedded Controllers.
All hard drives within a RAID array should be of the same capacity.
NEC Corporation Revision 2.1
– May, 2016
21
SYSTEM CONFIGURATION GUIDE
–
NEC Express5800/R110h-1
4.2.9 RAID 0/1 Controller with 0 MB Cache for 3.5-inch Drives
Category Product Name / Description Part Number
Storage Controller
Required
Cable
Drive Cage
RAID Controller (RAID 0/1)
Avago(LSI) MegaRAID SAS 9341-8i
RAID 0/1/10, Non-cache, Int. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA
6Gb/s
Internal SAS/SATA Cable
1 x Mini SAS HD to 4 x Single SATA, 1 set
3.5-inch Drive Cage
4 x 3.5-inch hot plug drive bays
NOTE:
All hard drives within a RAID array should be of the same capacity.
N8103-188
(Standard)
(Standard)
4.2.10 RAID 0/1 Controller with 1 GB Cache for 3.5-inch Drives
Category Product Name / Description Part Number
Storage Controller
Required
Flash Backup
Recommended
Cable
Drive Cage
RAID Controller (1GB, RAID 0/1)
Avago(LSI) MegaRAID SAS 9362-8i
RAID 0/1/10, 1GB, Int. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA 6Gb/s
Flash Backup Unit
for Avago(LSI) MegaRAID SAS 9362-8i
650mm Cable for Flash Backup Unit included
Internal SAS/SATA Cable
1 x Mini SAS HD to 4 x Single SATA, 1 set
3.5-inch Drive Cage
4 x 3.5-inch hot plug drive bays
NOTE:
All hard drives within a RAID array should be of the same capacity.
N8103-176
N8103-181
(Standard)
(Standard)
NEC Corporation Revision 2.1
– May, 2016
22
SYSTEM CONFIGURATION GUIDE
–
NEC Express5800/R110h-1
4.2.11 RAID 5/6 Controller with 1 GB Cache for 3.5-inch Drives
Category Product Name / Description
Storage Controller
Required
Flash Backup
Recommended
Cable
Drive Cage
RAID Controller (1GB, RAID 0/1/5/6)
Avago(LSI) MegaRAID SAS 9362-8i
RAID0/1/5/6/10/50/60, 1GB, Int. 8, PCIe 3.0 x8, SAS 12Gb/s,
SATA 6Gb/s
Flash Backup Unit
for Avago(LSI) MegaRAID SAS 9362-8i
650mm Cable for Flash Backup Unit included
Internal SAS/SATA Cable
1 x Mini SAS HD to 4 x Single SATA, 1 set
3.5-inch Drive Cage
4 x 3.5-inch hot plug drive bays
NOTE:
All hard drives within a RAID array should be of the same capacity.
4.2.12 RAID 5/6 Controller with 2 GB Cache for 3.5-inch Drives
Category Product Name / Description
Storage Controller
Required
Flash Backup
Recommended
Cable
Drive Cage
RAID Controller (2GB, RAID 0/1/5/6)
Avago(LSI) MegaRAID SAS 9362-8i
RAID0/1/5/6/10/50/60, 2GB, Int. 8, PCIe 3.0 x8, SAS 12Gb/s,
SATA 6Gb/s
Flash Backup Unit
for Avago(LSI) MegaRAID SAS 9362-8i
650mm Cable for Flash Backup Unit included
Internal SAS/SATA Cable
1 x Mini SAS HD to 4 x Single SATA, 1 set
3.5-inch Drive Cage
4 x 3.5-inch hot plug drive bays
NOTE:
All hard drives within a RAID array should be of the same capacity.
Part Number
N8103-177
N8103-181
(Standard)
(Standard)
Part Number
N8103-178
N8103-181
(Standard)
(Standard)
NEC Corporation Revision 2.1
– May, 2016
23
SYSTEM CONFIGURATION GUIDE
–
NEC Express5800/R110h-1
4.3 Supported Drives
4.3.1 2.5-inch Drives (1)
Category
Drive
4 slots available
SATA
HDD
Product Name / Description Part Number
500GB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
1TB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
2TB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 2 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-488
N8150-489
N8150-527
NOTE:
Hot plug insertion/removal is not supported with the embedded SATA non-RAID controller.
4.3.2 2.5-inch Drives (2)
Category
Drive
4 slots available
SATA
HDD
SATA
SSD
(ME)
SATA
SSD
(VE)
Product Name / Description Part Number
500GB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
1TB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
2TB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 2 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
200GB Hot Plug 2.5-inch SATA SSD
1 x 200 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME
400GB Hot Plug 2.5-inch SATA SSD
1 x 400 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME
800GB Hot Plug 2.5-inch SATA SSD
1 x 800 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME
200GB Hot Plug 2.5-inch SATA SSD
1 x 200 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE
400GB Hot Plug 2.5-inch SATA SSD
1 x 400 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE
800GB Hot Plug 2.5-inch SATA SSD
1 x 800 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE
1.6TB Hot Plug 2.5-inch SATA SSD
1 x 1.6 TB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE
N8150-488
N8150-489
N8150-527
N8150-725
N8150-726
N8150-727
N8150-732
N8150-733
N8150-734
N8150-735
4.3.3 2.5-inch Drives (3)
Category
Drive
Standard :
4 slots available
Max :
8 slots available
For 3.5-inch drive :
2 slots available
SAS
HDD
(512n)
Product Name / Description Part Number
300GB 10K Hot Plug 2.5-inch SAS HDD
1 x 300 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector
N8150-479
450GB 10K Hot Plug 2.5-inch SAS HDD
1 x 450 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector
N8150-480
600GB 10K Hot Plug 2.5-inch SAS HDD
1 x 600 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector
N8150-481
900GB 10K Hot Plug 2.5-inch SAS HDD
1 x 900 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector
N8150-482
1.2TB 10K Hot Plug 2.5-inch SAS HDD
1 x 1.2TB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector
300GB 15K Hot Plug 2.5-inch SAS HDD
1 x 300 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm, 512n sector
N8150-483
N8150-485
NEC Corporation Revision 2.1
– May, 2016
24
SYSTEM CONFIGURATION GUIDE
–
NEC Express5800/R110h-1
SATA
HDD
(512n)
SAS
SSD
(eMLC)
SATA
SSD
(ME)
SATA
SSD
(VE)
450GB 15K Hot Plug 2.5-inch SAS HDD
1 x 450 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm, 512n sector
N8150-486
600GB 15K Hot Plug 2.5-inch SAS HDD
1 x 600 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm, 512n sector
N8150-518
500GB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
1TB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
2TB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 2 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
200GB Hot Plug 2.5-inch SAS SSD
1 x 200 GB SAS SSD, eMLC, 2.5-inch, 12Gb/s, 512n sector
400GB Hot Plug 2.5-inch SAS SSD
1 x 400 GB SAS SSD, eMLC, 2.5-inch, 12Gb/s, 512n sector
200GB Hot Plug 2.5-inch SATA SSD
1 x 200 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME
400GB Hot Plug 2.5-inch SATA SSD
1 x 400 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME
800GB Hot Plug 2.5-inch SATA SSD
1 x 800 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME
200GB Hot Plug 2.5-inch SATA SSD
1 x 200 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE
400GB Hot Plug 2.5-inch SATA SSD
1 x 400 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE
800GB Hot Plug 2.5-inch SATA SSD
1 x 800 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE
1.6TB Hot Plug 2.5-inch SATA SSD
1 x 1.6 TB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE
N8150-488
N8150-489
N8150-527
N8150-721
N8150-722
N8150-725
N8150-726
N8150-727
N8150-732
N8150-733
N8150-734
N8150-735
NOTE:
All drives within a RAID array should be of the same type, capacity and rotation speed.
Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs SAS SSDs,
SATA SSD (ME), and SATA SSD (LE) can be mixed.
To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process.
The 2.5-inch SAS/SATA SSDs have limited lifetime. Refer to
4.3.4 2.5-inch Drives (4)
Category
Drive
Standard :4 slots available
Max :
8 slots available
SAS
HDD
(512n)
Product Name / Description Part Number
300GB 10K Hot Plug 2.5-inch SAS HDD
1 x 300 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector
N8150-479
450GB 10K Hot Plug 2.5-inch SAS HDD
1 x 450 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector
N8150-480
600GB 10K Hot Plug 2.5-inch SAS HDD
1 x 600 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector
N8150-481
900GB 10K Hot Plug 2.5-inch SAS HDD
1 x 900 GB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector
N8150-482
1.2TB 10K Hot Plug 2.5-inch SAS HDD
1 x 1.2TB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 512n sector
N8150-483
300GB 15K Hot Plug 2.5-inch SAS HDD
1 x 300 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm, 512n sector
N8150-485
450GB 15K Hot Plug 2.5-inch SAS HDD
1 x 450 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm, 512n sector
N8150-486
600GB 15K Hot Plug 2.5-inch SAS HDD
1 x 600 GB SAS HDD, 2.5-inch, 12Gb/s, 15,000 rpm, 512n sector
N8150-518
NEC Corporation Revision 2.1
– May, 2016
25
SYSTEM CONFIGURATION GUIDE
–
NEC Express5800/R110h-1
SAS
HDD
(4Kn)
SATA
HDD
(512n)
SAS
SSD
(eMLC)
SATA
SSD
(ME)
SATA
SSD
(VE)
1.8TB 10K Hot Plug 2.5-inch SAS HDD
1x 1.8TB SAS HDD, 2.5-inch, 12Gb/s, 10,000 rpm, 4Kn sector
N8150-490
500GB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
1TB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
2TB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 2 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm, 512n sector
200GB Hot Plug 2.5-inch SAS SSD
1 x 200 GB SAS SSD, eMLC, 2.5-inch, 12Gb/s, 512n sector
400GB Hot Plug 2.5-inch SAS SSD
1 x 400 GB SAS SSD, eMLC, 2.5-inch, 12Gb/s, 512n sector
200GB Hot Plug 2.5-inch SATA SSD
1 x 200 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME
400GB Hot Plug 2.5-inch SATA SSD
1 x 400 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME
800GB Hot Plug 2.5-inch SATA SSD
1 x 800 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, ME
200GB Hot Plug 2.5-inch SATA SSD
1 x 200 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE
400GB Hot Plug 2.5-inch SATA SSD
1 x 400 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector VE
800GB Hot Plug 2.5-inch SATA SSD
1 x 800 GB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE
1.6TB Hot Plug 2.5-inch SATA SSD
1 x 1.6 TB SATA SSD, MLC, 2.5-inch, 6b/s, 512n sector, VE
N8150-488
N8150-489
N8150-527
N8150-721
N8150-722
N8150-725
N8150-726
N8150-727
N8150-732
N8150-733
N8150-734
N8150-735
NOTE:
The 4Kn sector drives are make-to-order products. Please consult your sales representative in regard to production lead time.
When you select 4Kn sector HDD, confirm whether your applications support hard drives with 4Kn sector size. For more information, visit the NEC website at:
http://www.nec.com/en/global/prod/express/svropt/hdd/collateral/4KHDD_Precautions_EN.pdf
All drives within a RAID array should be of the same type, capacity and rotation speed.
Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs SAS SSDs,
SATA SSD (ME), and SATA SSD (LE) can be mixed.
Mix configurations of 4Kn sector HDDs and 512n sector HDDs are not supported.
To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process.
The 2.5-inch SAS/SATA SSDs have limited lifetime. Refer to
4.3.5 3.5-inch Drives (1)
Category
Drive
4slots available
SATA
HDD
Product Name / Description Part Number
500GB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
1TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
2TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
3TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 3 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
4TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 4 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
N8150-524
N8150-504
N8150-505
N8150-506
N8150-507
NOTE:
Hot plug insertion/removal is not supported with the embedded SATA non-RAID controller.
NEC Corporation Revision 2.1
– May, 2016
26
SYSTEM CONFIGURATION GUIDE
–
NEC Express5800/R110h-1
4.3.6 3.5-inch Drives (2)
Category
Drive
4 slots available
SATA
HDD
(512n)
Product Name / Description Part Number
500GB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
1TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
2TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
3TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 3 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
4TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 4 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 512n sector
6TB 7.2K Hot Plug 3.5-inch SATA HDD
1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm, 4Kn sector
N8150-524
N8150-504
N8150-505
N8150-506
N8150-507
N8150-503
SATA
HDD
(4Kn)
NOTE:
The 4Kn sector drives are make-to-order products. Please consult your sales representative in regard to production lead time.
Mix configurations of 4Kn sector HDDs and 512n sector HDDs are not supported.
When you select 4Kn sector HDD, confirm whether your applications support hard drives with 4 Kn sector size. For more information, visit the NEC website at:
http://www.nec.com/en/global/prod/express/svropt/hdd/collateral/4KHDD_Precautions_EN.pdf
All drives within a RAID array should be of the same capacity.
Embedded SATA RAID Controller does not support RAID 10 configured with 2 TB, 3 TB, and 4 TB
HDDs.
5 Optical Drive
Category
Internal
1 slot available
External
Product Name / Description
Internal Slim DVD-ROM drive
Slim DVD-ROM drive
DVD read speed: 8x (DVD-ROM / DVD-R / DVD-RW)
CD read speed: 24x (CD-ROM / CD-R/RW)
Internal DVD Super Multi Drive
Slim DVD Super Multi drive, not including writing software
DVD Read speed: 8x (DVD-R / DVD-RW / DVD-R DL / DVD+R /
DVD+RW / DVD+R DL / DVD-ROM)
DVD-RAM read speed: 5x
CD read speed: 24x (CD-ROM / CD-R/RW)
External DVD Super MULTI Drive
Slim DVD Super Multi drive, Bus powered, 1.5A required, not including writing software
DVD Read speed: 8x (DVD-R / DVD-RW / DVD-R DL / DVD+R /
DVD+RW / DVD+R DL / DVD-ROM)
DVD-RAM read speed: 5x
CD read speed: 24x (CD-ROM / CD-R/RW)
NOTE:
- Windows Server 2008 R2 installation is not supported with this drive.
NOTE:
An optical drive is required for maintenance and OS installation.
Up to 1 optical drive can be connected.
Part Number
N8151-134
N8151-135F
N8160-97F
NEC Corporation Revision 2.1
– May, 2016
27
SYSTEM CONFIGURATION GUIDE
–
NEC Express5800/R110h-1
6 PCI Card
Please refer to
Supported PCI cards and Installable Slots
with regard to the position of PCI slot which
can mount PCI card supported.
6.1 Network Interface Controller
Category
Adapter
SFP+
Module
Product Name / Description
GbE 1000BASE-T Adapter
Broadcom ® BCM5718 Gigabit Ethernet Controller
PCIe 2.0 x1
Dual Port 1000BASE-T Adapter
Broadcom ® BCM5718 Gigabit Ethernet Controller
PCIe 2.0 x1
Quad Port 1000BASE-T Adapter
Broadcom ® BCM5719 Gigabit Ethernet Controller
PCIe 2.0 x4
NOTE:
- Network cables with RJ-45 plug covers cannot be used.
10GbE 10GBASE SFP+ Adapter (SFP+/2ch)
Qlogic® NetXtreme II BCM57810 10G SFP+ Dual Port Network
Interface Card
PCIe 2.0 x8
NOTE:
- N8104-129 SFP+ Module is required to connect with an optical cable.
- Up to two SFP+ Modules can be installed.
- Up to two adapters can be installed.
- N8104-129 SFP+ Module is required to connect with an optical cable.
Dual Port 10GBASE-T Adapter
Intel® Ethernet Controller X540
PCIe 2.0(x8)
SFP+ Module (10G-SR)
1 x SFP+ Module for N8104-149
Part Number
N8104-150
N8104-151
N8104-152
N8104-149
N8104-153
N8104-129
NEC Corporation Revision 2.1
– May, 2016
28
SYSTEM CONFIGURATION GUIDE
–
NEC Express5800/R110h-1
NIC Teaming feature - NIC Teaming and bonding features
See the table below for supported network interfaces and OS combinations.
Windows Server 2008 R2 supports BASP (Broadcom Advanced Server Program) teaming while Windows
Server 2012 or later and Linux support teaming with bonding function supported by OS.
Network Interface Team Operating Systems
1GbE NIC
Embedded 1GbE NIC and
N8104-150/-151/-152
10GbE NIC
N8104-149
10GbE NIC
N8104-153
Up to four teams per one system
Up to four ports per one team
Up to two teams per one system
Up to two ports per one team
Up to one teams per one system
Up to two ports per one team
Windows Server 2008 R2
Windows Server 2012
Windows Server 2012 R2
Red Hat Enterprise Linux
Windows Server 2008 R2
Windows Server 2012
Windows Server 2012 R2
Red Hat Enterprise Linux
Windows Server 2012
Windows Server 2012 R2
Red Hat Enterprise Linux
* RHEL : Red Hat Enterprise Linux
NOTE:
NIC Teaming feature is not supported on iSCSI interfaces.
The network interfaces for each teaming must be the same.
When 10GbE and 1GbE NIC teams are mixed, the teams must be up to four per one system.
Using iSCSI
See the table below for supported network interfaces and OS combinations.
Category Network Interface Operating Systems
1GbE
10GbE
Embedded 1GbE NIC/
N8104-150/-151/-152
N8104-149
N8104-153
Windows Server 2008 R2, Windows Server 2012,
Windows Server 2012 R2, Red Hat Enterprise Linux 6, Red Hat Enterprise
Linux 7, VMware
Windows Server 2008 R2, Windows Server 2012,
Windows Server 2012 R2, Red Hat Enterprise Linux 6, Red Hat Enterprise
Linux 7, VMware
Windows Server 2012, Windows Server 2012 R2, Red Hat Enterprise Linux
6, Red Hat Enterprise Linux 7, VMware
NOTE:
NIC Teaming feature is not supported on iSCSI interfaces.
NEC Corporation Revision 2.1
– May, 2016
29
SYSTEM CONFIGURATION GUIDE
–
NEC Express5800/R110h-1
6.2 External Storage Controller
6.2.1 RAID Controller
Category Product Name / Description Part Number
Controller RAID Controller (2GB, RAID0/1/5/6)
Avago(LSI) MegaRAID SAS 9380-8e
RAID0/1/5/6/10/50/60, 2GB, Ext. 8, PCIe 3.0 x8, SAS 12Gb/s,
SATA 6Gb/s, Flash Backup Unit included
N8103-179
NOTE:
To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process.
It is recommended to set RAID array configuration drives less than eight in order to minimize the risk of becoming multiple hard drives failure.
6.2.2 Fibre Channel / SAS Controller
Category
Fibre Channel
SAS
Product Name / Description
Fibre Channel Controller (1ch)
Emulex LightPulse LPe1250-F8 Host Bus Adapter
8Gb/s, Optical, PCIe 2.0 x8
Fibre Channel Controller (2ch)
Emulex LightPulse LPe12002-M8 Host Bus Adapter
8Gb/s, Optical, PCIe 2.0 x8
Fibre Channel Controller (1ch)
Emulex LightPulse LPe16000B-M6 Host Bus Adapter
16Gb/s, Optical, PCIe 3.0 x8
NOTE:
- One controller can be installed on Pentium processor systems.
Fibre Channel Controller (2ch)
Emulex LightPulse LPe16002B-M6 Host Bus Adapter
16Gb/s, Optical, PCIe 3.0 x8
NOTE:
- The controller is supported only with Xeon processor.
SAS Controller
LSI SAS9212-4i4e Host Bus Adapter
6Gb/s SAS, Int. 4 / Ext. 4, 7-pin SATA / SFF-8088, PCIe 2.0 x8
SAS Controller
LSI SAS9300-8e Host Bus Adapter
12Gb/s SAS, ext. 8(SFF-8644 x2), PCIe 3.0 x8
Part Number
N8190-159
N8190-160
N8190-157A
N8190-158A
N8103-142
N8103-184
6.3 Graphics Accelerator
Product Name / Description
Graphics Accelerator
NVIDIA NVS 315, PCI Express 2.0 (x16)
1x DVI-VGA connector, DMS-59-DVI-I branch cable included
NOTE:
The standard VGA connector cannot be used when this option is installed.
The remote KVM feature is not supported when this option is installed.
Part Number
N8105-48
NEC Corporation Revision 2.1
– May, 2016
30
SYSTEM CONFIGURATION GUIDE
–
NEC Express5800/R110h-1
6.4 Serial Port Adapter
Product Name / Description
Serial port adapter
Serial port fixed to PCI bracket
NOTE:
Up to one Serial Port Adapter can be installed.
Part Number
N8117-01A
NEC Corporation Revision 2.1
– May, 2016
31
SYSTEM CONFIGURATION GUIDE
–
NEC Express5800/R110h-1
7 Other Add-in Components
7.1 Cooling Fan Kit
Product Name / Description Part Number
Non-redundant Fan Kit
Non-hot plug cooling fan for R110h-1
Redundant Fan Kit
Non-hot plug cooling fan for R110h-1
NOTE:
- The redundant fan kit is necessary to operate the server at temperatures over 40°C with
N8181-146F High temperature resistant Kit
NOTE:
One of the fan kits must be installed.
N8181-115F
N8181-111F
7.2 Trusted Platform Module Kit
Product Name / Description Part Number
Trusted Platform Module Kit
TPM 2.0 module
N8115-23
NOTE:
The kit is not available in China.
The kit is not removable after attachment.
"TPM Support" in BIOS setup menu must be activated prior to use of this kit.
To use Windows BitLocker drive encryption, be sure to keep the "recovery password" of BitLocker function. The recovery password is required to restore data for hardware replacement during a system error.
7.3 Internal Flash Memory
Available socket: 1
Product Name / Description
VMware ESXi Base Kit
Internal USB flash memory to install VMware ESXi system
NOTE:
The kit does not include VMware ESXi installation media and license.
At least 5GB of memory is required for VMware ESXi 5.5/VMware ESXi 6.0.
Part Number
N8106-011
7.4 High temperature resistant Kit
Product Name / Description Part Number
High temperature resistant Kit
Required for high temperature operation over 40°C (up to 45°C)
NOTE:
Supported for N8100-2334F non-hot plug power supply model only.
To apply this option, there are some configuration limitations below.
N8181-146F
Required System Configuration:
- The power supply must be non-redundant power supply and N8181-111F
Redundant Fan Kit is required.
- Up to 3 hard drives.
- Any of N8103-181 (Flash Backup Unit), N8103-179 (RAID Controller (2GB, RAID0/1/5/6)), N8151-134 (
Internal
Slim DVD-ROM drive) or N8151-135F (Internal DVD Super Multi Drive) must not be installed.
- Windows Server 2008 R2 is not supported with this option.
NEC Corporation Revision 2.1
– May, 2016
32
SYSTEM CONFIGURATION GUIDE
–
NEC Express5800/R110h-1
7.5 Flash FDD
Choose the Flash FDD if you need to prepare an alternative device for a floppy drive.
Product Name / Description
Flash FDD
USB flash emulating USB floppy disk, Native capacity 1.44 MB
NOTE:
Up to one drive can be connected.
Part Number
N8160-96
NEC Corporation Revision 2.1
– May, 2016
33
SYSTEM CONFIGURATION GUIDE
–
NEC Express5800/R110h-1
8 Add-on Components
8.1 17-inch LCD Console Drawer
Category
Drawer w/ KVM
Drawer w/o KVM
Product Name / Description Part Number
Drawer 17-inch LCD Console Drawer (8 port)
17-inch LCD, US 83-keys Keyboard, Optical mouse, 8 port
KVM switch, 1U height
Cable Switch Unit Connection Cable Set (USB, 1.8m)
1.8 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin
USB A
Switch Unit Connection Cable Set (USB, 3m)
3 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin
USB A
Switch Unit Connection Cable Set (USB, 5m)
5 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin
USB A
Drawer 17inch LCD Console Unit 1U
17-inch LCD, US 83-keys Keyboard, Optical mouse, 1U height,
4-pin USB B to 4-pin USB A cable 2 m, PS/2 Y-splitter cable 2m,
15-pin mini D-sub VGA cable 2 m
17inch LCD Console Drawer (1 port)
17-inch LCD, US 103-keys Keyboard with 10-key, Touch pad with 3-button, 1U height, 4-pin USB B to 4-pin USB A cable 1.8 m, Two PS/2 cable 1.8 m, 15-pin mini D-sub VGA cable 1.8 m
Keypad Keyboard Unit (JP)
JP 108-keys Keyboard with 10-key for N8143-108F 17inch LCD
Console Drawer (1 port)
Keyboard Unit (UK)
UK 104-keys Keyboard with 10-key, for N8143-108F 17inch
LCD Console Drawer (1 port)
N8143-106F
K410-118(1A)
K410-118(03)
K410-118(05)
N8143-105F
N8143-108F
N8143-109
N8143-111
8.2 KVM Switch
Category Product Name / Description
KVM Switch
Cable KVM
Server Switch Unit (8 server)
1U USB 8 port KVM switch
Switch Unit Connection Cable Set (USB,1.8m)
1.8 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin
USB A
Switch Unit Connection Cable Set (USB,3m)
3 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin
USB A
Switch Unit Connection Cable Set (USB,3m)
5 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin
USB A
Cascading Switch Unit Connection Cable 1.8 m
1.8 m, 1 x 15-pin mini D-sub - 1x 15-pin mini D-Sub / 2x PS/2
Part Number
N8191-14F
K410-118(1A)
K410-118(03)
K410-118(05)
K410-119(1A)
NEC Corporation Revision 2.1
– May, 2016
34
SYSTEM CONFIGURATION GUIDE
–
NEC Express5800/R110h-1
8.3 Server Management License
The server integrates the EXPRESSSCOPE Engine 3 as standard. Refer to
standard management features. For more extensive remote KVM and remote media features, choose the following kit.
Product Name / Description Part Number
Remote KVM and Media License Kit
License for one server.
Remote KVM and remote media are enabled regardless of OS status.
Remote KVM:
- Displays a graphics console on the web browser of the remote terminal
(PC/server).
- Controls keyboard and mouse via the remote terminals' web browser
Remote media:
-
Enables the user to use the CD / DVD / FD / Flash memory of the remote terminals
(PC/server) as if accessing the local drives.
N8115-04
NOTE:
Remote KVM and remote media features are not available for virtual machines.
NEC Corporation Revision 2.1
– May, 2016
35
SYSTEM CONFIGURATION GUIDE
–
NEC Express5800/R110h-1
References
Boot Mode Setting
The server supports Legacy mode and UEFI mode (default) as an OS Boot Mode. See the table below for the Boot Mode and X2APIC setting for each Operating System. As the default settings at the factory, UEFI mode is set as OS Boot mode and X2APIC is enabled. Refer to the User’s Guide and change the settings before installing an Operating System requiring Legacy Mode.
Operating System
Windows Server 2008 R2 (x64)
Windows Server 2012
Windows Server 2012 R2
Red Hat Enterprise Linux 6(x86_64)
Red Hat Enterprise Linux 7
VMware ESXi 5.5 Update3
VMware ESXi 6 Update1
Supported Boot Mode
Legacy
UEFI
UEFI
UEFI
UEFI
Legacy
Legacy
Supported X2APIC Setting
Disabled
Enabled
Enabled
Enabled
Enabled
Disabled
Disabled
NEC Corporation Revision 2.1
– May, 2016
36
SYSTEM CONFIGURATION GUIDE
–
NEC Express5800/R110h-1
Server Management
The EXPRESSSCOPE Engine 3, integrated into the server, provides superior remote control and system management features listed in the table below.
Standard
With Remote KVM and Media License kit
Hardware monitoring
Temperature/fan/voltage/power consumption/SystemLAN/degeneration(memory)
Hardware configuration information collection
Hardware event log collection
Boot monitoring
BIOS/POST stall, Booting, OS stall, shutdown
Alerting
HW error, Boot error and OS panic
(by SNMP, E-Mail)
Remote KVM
(via LAN)
POST/BIOS setup, ROM utility
Panic screen, Boot screen
CUI-based screen (OS console)
Remote control
(via LAN)
GUI-based screen (OS console)
Remote KVM Video Record
Remote reset/power on-off/ dump
Remote Power Capping
BIOS/BMC FW update
Remote BIOS setup(partial configuration only)
OS shutdown
Maintenance
Others
Remote media (CD/DVD/FD/USB)
CLP (Command Line Protocol) (DMTF compliant)
Remote control via Web browser (multi user login at the same time)
Scheduling (without UPS, require NEC ESMPRO
Manager)
BIOS setting by using XML file
EXPRESSSCOPE® Profile key
(Backup/restore BIOS/BMC setup information)
Set automatic IP address via DNS/DHCP
LDAP/Active Directory verification/user control
Clock synchronization of main unit and the RTC
Access log collection
1
Industry
Standard
IPMI support
The optional serial port is not available for the feature.
2
The feature is not supported on VMware ESXi systems.
3
Monitoring boot screens is not supported on VMware systems.
4
In VMware systems, only the direct console user interface is supported.
2
2
2.0
1
1,3
1,4
-
-
2
-
2.0
2
2
2
NEC Corporation Revision 2.1
– May, 2016
37
SYSTEM CONFIGURATION GUIDE
–
NEC Express5800/R110h-1
Endurance of SSD
The 2.5-inch SAS/SATA SSDs have limited lifetime, which can only be written a limited number of times before it fails.
The warranty period of SSD is the stated period of warranty or until the total bytes of written value (PBW) exceeds the limit value, whichever occurs first. It is recommended to check the total bytes of written value periodically.
Refer to the table below for the write endurance (PBW and DWPD), warranty period and monitoring tool.
SSD Lifetime
Part
Number
Product Name PBW DWPD Period Monitoring Tool
SAS SSD
N8150-721 200GB Hot Plug
2.5-inch SAS SSD
N8150-722 400GB Hot Plug
2.5-inch SAS SSD
SATA SSD (Middle Endurance)
N8150-725 200GB Hot Plug
2.5-inch SATA SSD
N8150-726 400GB Hot Plug
2.5-inch SATA SSD
N8150-727 800GB Hot Plug
2.5-inch SATA SSD
SATA SSD (Value Endurance)
N8150-732 200GB Hot Plug
2.5-inch SATA SSD
3.6PBW
7.3PBW
3.6PBW
7.3PBW
14.6PBW
1.1PBW
10 Times
10 Times
10 Times
10 Times
10 Times
3 Times
3 Years
3 Years
3 Years
3 Years
3 Years
3 Years
Universal RAID Utility,
EXPRESSBUILDER
(System Test and
Diagnostics)
N8150-733 400GB Hot Plug
2.5-inch SATA SSD
N8150-734 800GB Hot Plug
2.5-inch SATA SSD
3.0PBW
5.3PBW
3 Times
3 Times
3 Years
3 Years
N8150-735 1.6TB Hot Plug
2.5-inch SATA SSD
10.7PBW 3 Times 3 Years
PBW(Peta-Bytes Write): Total amount of data that can be written into the SSD. 1PB=1,000TB.
DWPD(Drive Writes per Day): Rewrite capacity of the SSD per day.
Check the lifetime of SSD by monitoring tool regularly.
It is recommended to replace the SSD before it reaches its end of life. For repurchase, please contact your sales representative.
For detailed operating methods of monitoring tool, refer to the User
’s Guide.
NEC Corporation Revision 2.1
– May, 2016
38
SYSTEM CONFIGURATION GUIDE
–
NEC Express5800/R110h-1
OS Support Matrix for PCI Cards and Embedded Controllers
Part Number
-
-
-
N8103-188
N8103-176
N8103-177
N8103-178
N8190-158A
N8190-157A
N8103-179
N8103-184
N8104-153
N8104-149
N8190-160
N8190-159
N8103-142
N8104-152
N8104-151
N8104-150
Product Name
Embedded SATA non-RAID Controller
Embedded SATA RAID Controller
Embedded 1GbE NIC
RAID controller (RAID0/1)
RAID Controller (1GB, RAID 0/1)
RAID Controller (1GB, RAID 0/1/5/6)
RAID Controller (2GB, RAID 0/1/5/6)
Fibre Channel Controller (2ch)
Fibre Channel Controller (1ch)
RAID Controller (2GB, RAID0/1/5/6)
SAS Controller
Dual Port 10GBASE-T Adapter
10GBASE SFP+ Adapter (SFP+/2ch)
Fibre Channel Controller (2ch)
Fibre Channel Controller (1ch)
SAS Controller
Quad Port 1000BASE-T Adapter
Dual Port 1000BASE-T Adapter
1000BASE-T Adapter
- - - - -
-
-
NEC Corporation Revision 2.1
– May, 2016
39
SYSTEM CONFIGURATION GUIDE
–
NEC Express5800/R110h-1
Supported PCI cards and Installable Slots
Slots
Part Number Product Name 1A 1B 1C
N8103-188
N8103-176
RAID controller (RAID0/1)
RAID Controller (1GB, RAID 0/1)
RAID Controller (1GB, RAID 0/1/5/6)
(1)
(1)
(1)
-
-
-
-
-
-
N8103-177
N8103-178
N8190-158A
RAID Controller (2GB, RAID 0/1/5/6)
Fibre Channel Controller (2ch)
Fibre Channel Controller (1ch)
(1)
-
-
-
(1)
(1)
-
-
(2)
N8190-157A
N8103-179
N8103-184
RAID Controller (2GB, RAID0/1/5/6)
SAS Controller
Dual Port 10GBASE-T Adapter
-
-
-
(1)
(1)
(1)
(2)
(2)
(2)
N8104-153
N8104-149
N8190-160
10GBASE SFP+ Adapter (SFP+/2ch)
Fibre Channel Controller (2ch)
Fibre Channel Controller (1ch)
-
-
-
(1)
(1)
(1)
(2)
(2)
(2)
N8190-159
N8103-142
SAS Controller - (1) (2)
N8104-152
Quad Port 1000BASE-T Adapter - - (1)
N8104-151
Dual Port 1000BASE-T Adapter - (1) (2)
N8104-150
1000BASE-T Adapter - (1) (2)
N8117-01A
Serial port adapter - (1) (2)
The number between parentheses shows the population priority (recommendation). For example, install N8103-176 in the slot #1 and N8104-153 in the slot #2 when you have those cards.
For the configuration limitation for VMware ESXi, refer to the following documents.
VMware ESXi5.5 https://www.vmware.com/pdf/vsphere5/r55/vsphere-55-configuration-maximums.pdf
VMware ESXi6.0 https://www.vmware.com/pdf/vsphere6/r60/vsphere-60-configuration-maximums.pdf
NEC Corporation Revision 2.1
– May, 2016
40
SYSTEM CONFIGURATION GUIDE
–
NEC Express5800/R110h-1
Secure Boot Mode
This server supports Secure Boot. It is supported with UEFI Boot mode and protects the security by only allowing software programs with digital signature to run. The supported operating systems, software, and boot devices are below. The default setting of Secure Boot is disabled. Keep the setting disabled to use other operating systems and/or software.
Supported OS and Software for Secure Boot Mode
Operating System
Windows Server 2012
Windows Server 2012 R2
Software Related to Boot
Supported Boot Mode
UEFI
UEFI
Supported Boot Mode
System Diagnostics Utility
EXPRESSBUILDER
UEFI
UEFI
Supported Boot Device for Secure Boot Mode
Supported Boot Device
RAID controller (RAID0/1)
RAID controller (1GB, RAID0/1)
RAID controller (1GB, RAID0/1/5/6)
RAID controller (2GB, RAID0/1/5/6)
RAID controller (2GB, RAID0/1/5/6)
Fibre Channel Controller (1ch)
Fibre Channel Controller (2ch)
Secure Boot Mode
Secure Boot Mode
Part Number
N8103-188
N8103-176
N8103-177
N8103-178
N8103-179
N8190-157A
N8190-158A
NEC Corporation Revision 2.1
– May, 2016
41
SYSTEM CONFIGURATION GUIDE
–
NEC Express5800/R110h-1
Copyright Notice and Liability Disclaimer
The information contained herein is subject to change without notice.
Microsoft and Windows Server are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries
Intel and Xeon are registered trademarks or trademarks of Intel Corporation or its subsidiaries in the United
States and other countries.
Linux is a trademark of Linus Torvalds.
Red Hat is a registered trademark of Red Hat, Inc. in the U.S.
All other products, brands, or trade names used in this document are trademarks or registered trademarks of their respective holders.
NEC shall not be liable for technical or editorial errors or omissions contained herein.
For hard drive capacity measurements, 1 GB = 1 billion bytes. Actual formatted capacity is less.
NEC Corporation Revision 2.1
– May, 2016
42
SYSTEM CONFIGURATION GUIDE
–
NEC Express5800/R110h-1
Revision History
Revision Date
2.1 May 17, 2016
2.0
1.1
1.0
April 26, 2016
February 2, 2016
January 22, 2016
Description
Others:
Added DVD read speed information
New products added:
Graphics Accelerator N8105-48
Others:
Added a note for Windows Server 2008 R2 installation
Added a note for N8160-97F External DVD Super MULTI Drive
Added a note for High temperature resistant Kit
Added SATA SSDs for the RAID configuration for RAID 0/1 (Embedded SATA
RAID) (4.3.2)
Corrected typos and errors.
Initial release
NEC Corporation Revision 2.1
– May, 2016
43
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 3 Technical Specification
- 3 Key Features
- 3 Specification
- 3 2.5-inch Drive Model
- 3 (1/2)
- 5 (2/2)
- 6 3.5-inch Drive Model
- 6 (1/2)
- 8 (2/2)
- 10 External Views
- 10 Front and Rear Views
- 10 Front View for 2.5-inch Drive Model
- 10 Front View for 3.5-inch Drive Model
- 11 Rear View for Non-redundant PSU Configuration
- 11 Rear View for Redundant PSU Configuration
- 12 Dimensions (mm)
- 13 Configuration Diagram
- 13 2.5-inch Drive Model
- 13 3.5-inch Drive Model (Non-redundant PSU)
- 14 3.5-inch Drive Model (Redundant PSU)
- 14 Expansion Slots
- 15 Server Configuration
- 15 1 Base Models
- 15 2 Processor
- 16 3 Memory
- 16 Maximum Available Memory
- 17 4 Internal Hard Disk Drives
- 17 4.1 RAID Configuration
- 17 4.1.1 2.5-inch Drive
- 18 4.1.2 3.5-inch Drive
- 19 4.2 Required Components for RAID Configuration
- 19 4.2.1 Embedded SATA non-RAID Controller for 2.5-inch Drives
- 19 4.2.2 Embedded SATA RAID Controller for 2.5-inch Drives
- 19 4.2.3 RAID 0/1 Controller without Cache for 2.5-inch Drives
- 20 4.2.4 RAID 0/1 Controller with 1 GB Cache for 2.5-inch Drives
- 20 4.2.5 RAID 5/6 Controller with 1 GB Cache for 2.5-inch Drives
- 21 4.2.6 RAID 5/6 Controller with 2 GB Cache for 2.5-inch Drives
- 21 4.2.7 Embedded SATA non-RAID Controller for 3.5-inch Drives
- 21 4.2.8 Embedded SATA RAID Controller for 3.5-inch Drives
- 22 4.2.9 RAID 0/1 Controller with 0 MB Cache for 3.5-inch Drives
- 22 4.2.10 RAID 0/1 Controller with 1 GB Cache for 3.5-inch Drives
- 23 4.2.11 RAID 5/6 Controller with 1 GB Cache for 3.5-inch Drives
- 23 4.2.12 RAID 5/6 Controller with 2 GB Cache for 3.5-inch Drives
- 24 4.3 Supported Drives
- 24 4.3.1 2.5-inch Drives (1)
- 24 4.3.2 2.5-inch Drives (2)
- 24 4.3.3 2.5-inch Drives (3)
- 25 4.3.4 2.5-inch Drives (4)
- 26 4.3.5 3.5-inch Drives (1)
- 27 4.3.6 3.5-inch Drives (2)
- 27 5 Optical Drive
- 28 6 PCI Card
- 28 6.1 Network Interface Controller
- 29 NIC Teaming feature - NIC Teaming and bonding features
- 29 Using iSCSI
- 30 6.2 External Storage Controller
- 30 6.2.1 RAID Controller
- 30 6.2.2 Fibre Channel / SAS Controller
- 30 6.3 Graphics Accelerator
- 31 6.4 Serial Port Adapter
- 32 7 Other Add-in Components
- 32 7.1 Cooling Fan Kit
- 32 7.2 Trusted Platform Module Kit
- 32 7.3 Internal Flash Memory
- 32 7.4 High temperature resistant Kit
- 33 7.5 Flash FDD
- 34 8 Add-on Components
- 34 8.1 17-inch LCD Console Drawer
- 34 8.2 KVM Switch
- 35 8.3 Server Management License
- 36 References
- 36 Boot Mode Setting
- 37 Server Management
- 38 Endurance of SSD
- 38 SSD Lifetime
- 39 OS Support Matrix for PCI Cards and Embedded Controllers
- 40 Supported PCI cards and Installable Slots
- 41 Secure Boot Mode
- 41 Supported OS and Software for Secure Boot Mode
- 41 Supported Boot Device for Secure Boot Mode
- 42 Copyright Notice and Liability Disclaimer
- 43 Revision History