Cisco ASR 903 Series Aggregation Services Router

Cisco ASR 903 Series Aggregation
Services Router Hardware Installation
Guide
30 March 2012
Americas Headquarters
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
USA
http://www.cisco.com
Tel: 408 526-4000
800 553-NETS (6387)
Fax: 408 527-0883
Text Part Number: OL-25178-02
THE SPECIFICATIONS AND INFORMATION REGARDING THE PRODUCTS IN THIS MANUAL ARE SUBJECT TO CHANGE WITHOUT NOTICE. ALL
STATEMENTS, INFORMATION, AND RECOMMENDATIONS IN THIS MANUAL ARE BELIEVED TO BE ACCURATE BUT ARE PRESENTED WITHOUT
WARRANTY OF ANY KIND, EXPRESS OR IMPLIED. USERS MUST TAKE FULL RESPONSIBILITY FOR THEIR APPLICATION OF ANY PRODUCTS.
THE SOFTWARE LICENSE AND LIMITED WARRANTY FOR THE ACCOMPANYING PRODUCT ARE SET FORTH IN THE INFORMATION PACKET THAT
SHIPPED WITH THE PRODUCT AND ARE INCORPORATED HEREIN BY THIS REFERENCE. IF YOU ARE UNABLE TO LOCATE THE SOFTWARE LICENSE
OR LIMITED WARRANTY, CONTACT YOUR CISCO REPRESENTATIVE FOR A COPY.
NOTWITHSTANDING ANY OTHER WARRANTY HEREIN, ALL DOCUMENT FILES AND SOFTWARE OF THESE SUPPLIERS ARE PROVIDED “AS IS” WITH
ALL FAULTS. CISCO AND THE ABOVE-NAMED SUPPLIERS DISCLAIM ALL WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING, WITHOUT
LIMITATION, THOSE OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT OR ARISING FROM A COURSE OF
DEALING, USAGE, OR TRADE PRACTICE.
IN NO EVENT SHALL CISCO OR ITS SUPPLIERS BE LIABLE FOR ANY INDIRECT, SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES, INCLUDING,
WITHOUT LIMITATION, LOST PROFITS OR LOSS OR DAMAGE TO DATA ARISING OUT OF THE USE OR INABILITY TO USE THIS MANUAL, EVEN IF CISCO
OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
Cisco and the Cisco logo are trademarks or registered trademarks of Cisco and/or its affiliates in the U.S. and other countries. To view a list of Cisco trademarks, go to this
URL: www.cisco.com/go/trademarks. Third-party trademarks mentioned are the property of their respective owners. The use of the word partner does not imply a partnership
relationship between Cisco and any other company. (1110R)
Any Internet Protocol (IP) addresses and phone numbers used in this document are not intended to be actual addresses and phone numbers. Any examples, command display
output, network topology diagrams, and other figures included in the document are shown for illustrative purposes only. Any use of actual IP addresses or phone numbers in
illustrative content is unintentional and coincidental.
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
© 2012 Cisco Systems, Inc. All rights reserved.
C O N T E N T S
CHAPTER
1
Cisco ASR 903 Series Aggregation Services Router Overview
Cisco ASR 903 Series Aggregation Services Router Features
System Specifications 1-2
DC Power Supply 1-3
DC Power Specifications 1-4
DC Power Supply Features 1-4
Redundancy 1-4
Dying Gasp 1-5
Status LEDs 1-5
Fan Tray 1-5
RSP Modules 1-6
Supported RSPs 1-7
Supported RSP Features 1-7
RSP Redundancy 1-7
Network Timing Interfaces 1-8
RSP Interfaces 1-8
Interface Modules 1-9
Gigabit Ethernet SFP Interface Module 1-9
Gigabit Ethernet RJ45 Interface Module 1-10
10 Gigabit Ethernet XFP Interface Module 1-11
T1/E1 Interface Module 1-12
OC-3 Interface Module 1-13
Temperature Sensor 1-13
Serial Number Label Location 1-14
Interface Numbering
CHAPTER
2
1-1
1-1
1-14
Regulatory Compliance
1-15
Preparing for Installation
2-1
Safety Guidelines 2-1
Standard Warning Statements 2-2
Safety Guidelines for Personal Safety and Equipment Protection
Safety Precautions for Module Installation and Removal 2-3
Safety with Electricity 2-4
Power Supply Considerations 2-8
2-3
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
OL-25178-02
iii
Contents
Preventing ESD Damage
2-8
Site Planning 2-9
General Precautions 2-9
Site Planning Checklist 2-9
Site Selection Guidelines 2-10
Environmental Requirements 2-10
Physical Characteristics 2-10
Air Flow Guidelines 2-10
Floor Loading Considerations 2-11
Site Power Guidelines 2-11
Electrical Circuit Requirements 2-12
Site Cabling Guidelines 2-12
Asynchronous Terminal Connections 2-13
Interference Considerations 2-13
Rack-Mounting Guidelines 2-14
Precautions for Rack-Mounting 2-14
Rack Selection Guidelines 2-15
Equipment Rack Guidelines 2-15
Installation Checklist 2-17
Creating a Site Log 2-18
Receiving the Cisco ASR 903 Series Aggregation Services Router
Chassis-Lifting Guidelines 2-19
Tools and Equipment 2-19
Unpacking and Verifying the Shipped Contents 2-20
CHAPTER
3
Installing the Cisco ASR 903 Series Aggregation Services Router
Prerequisites
2-18
3-1
3-1
Installing the Router in a Rack 3-1
Installing the Chassis Brackets 3-2
Installing the Router Chassis in the Rack 3-3
Attaching the Cable Management Brackets 3-4
Installing the Chassis Ground Connection
Installing the Fan Tray 3-8
Removing and Replacing the Fan Tray
3-5
3-8
RSP Installation 3-10
Installing an RSP Module 3-11
Removing an RSP Module 3-12
Hot-Swapping an RSP Module 3-13
Interface Module Installation
3-14
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
iv
OL-25178-02
Contents
Installing an Interface Module 3-14
Removing an Interface Module 3-15
Hot-Swapping an Interface Module 3-15
Installing the Power Supply 3-16
Preventing Power Loss 3-16
Power Connection Guidelines 3-16
Guidelines for DC-Powered Systems 3-17
Installing the DC Power Supply 3-17
Installing the Power Supply Module 3-17
Installing the Terminal Block 3-18
Activating the DC Power Supply 3-21
Removing and Replacing the DC Power Supply 3-22
Connecting the Cisco ASR 903 Series Aggregation Services Router to the Network
Connecting Console Cables 3-23
Connecting to the Serial Port using Microsoft Windows 3-24
Connecting to the Console Port using Mac OS X 3-26
Connecting to the Console Port using Linux 3-26
Installing the Cisco Microsoft Windows USB Device Driver 3-27
Uninstalling the Cisco Microsoft Windows USB Driver 3-28
Connecting to the Auxiliary Port 3-29
Connecting a Management Ethernet Cable 3-30
Installing and Removing SFP and XFP Modules 3-31
Connecting a USB Flash Device 3-31
Removing a USB Flash Device 3-32
Connecting Timing Cables 3-32
Connecting Cables to the BITS Interface 3-32
Connecting Cables to a GPS Interface 3-33
Connecting Ethernet Cables 3-34
Connecting Cables to SFP Modules 3-34
Connecting T1/E1 cables 3-34
Installing the Cable Connector 3-35
RJ45 Cable Pinouts 3-36
Connecting Cables to the Patch Panel 3-36
Recommended Patch Panel 3-36
Connecting the Fan Tray Alarm Port 3-37
Connector and Cable Specifications 3-37
CHAPTER
4
Cisco ASR 903 Series Aggregation Services Router Initial Configuration
Checking Conditions Prior to System Startup
3-23
4-1
4-1
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
OL-25178-02
v
Contents
Powering Up the Cisco ASR 903 Series Aggregation Services Router
Verifying the Front Panel LEDs 4-5
Verifying the Hardware Configuration 4-5
Checking Hardware and Software Compatibility 4-5
4-2
Configuring the Cisco ASR 903 Series Aggregation Services Router at Startup
Using the Console Interface 4-6
Configuring Global Parameters 4-7
Checking the Running Configuration Settings 4-8
Saving the Running Configuration to NVRAM 4-8
Safely Powering Off the Cisco ASR 903 Series Aggregation Services Router
CHAPTER
5
Troubleshooting
4-6
4-8
5-1
Pinouts 5-1
BITS Port Pinout 5-1
GPS Port Pinout 5-2
Time of Day Port Pinout 5-2
Alarm Port Pinout 5-3
Console/Aux RJ45 RS232 Serial Port Pinout
T1/E1 Port Pinout 5-4
Management Ethernet Port Pinout 5-5
USB Console Port Pinout 5-6
USB Flash/MEM Port Pinout 5-6
Fiber-Optic Specifications 5-7
5-3
LED Summary 5-7
RSP LEDs 5-7
Interface Module LEDs 5-8
OC-3 Interface Module LEDs 5-9
T1/E1 Interface Module LEDs 5-9
Power Supply LEDs 5-10
Fan Tray LEDs 5-10
CHAPTER
A
Site Log
A-1
INDEX
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
vi
OL-25178-02
About this Book
Revised: 24 February 2012, OL-25178-02
The preface describes the revision history, audience, organization, and conventions of Cisco ASR 903
Series Aggregation Services Router Hardware Installation Guide. It also lists sources for obtaining
additional information and technical assistance from Cisco Systems.
•
Document Revision History, page vii
•
Document Audience, page vii
•
Document Organization, page viii
•
Document Conventions, page viii
•
Obtaining Documentation and Submitting a Service Request, page ix
Document Revision History
The following table lists the major changes made to this document for each release.
Revision
Date
Change Summary
OL-25178-02
30 March 2012
Updated supported SFPs for IOS XE Release 3.6.
OL-25178-02
24 February 2012
Added power draw and installation torque values.
OL-25178-01
16 December 2011
First release published.
Document Audience
This guide is intended for users who are responsible for installing the Cisco ASR 903 Series Aggregation
Services Router. It is intended for users who may not be familiar with the initial configuration and
troubleshooting tasks, the relationship among tasks, or the Cisco IOS software commands necessary to
perform particular tasks.
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
OL-25178-02
vii
About this Book
Document Organization
This guide includes the following chapters and appendix:
Title
Description
Chapter 1, “Cisco ASR 903 Series
Aggregation Services Router
Overview”
This chapter provides an overview of the Cisco
ASR 903 Series Aggregation Services Router.
Chapter 2, “Preparing for
Installation”
This chapter provides site preparation guidelines
for installing the Cisco ASR 903 Series
Aggregation Services Router.
Chapter 3, “Installing the Cisco ASR This chapter describes the Cisco ASR 903 Series
903 Series Aggregation Services
Aggregation Services Router and how to install it.
Router”
Chapter 4, “Cisco ASR 903 Series
Aggregation Services Router Initial
Configuration”
This chapter describes how to start the Cisco ASR
903 Series Aggregation Services Router and
create an initial system configuration.
Chapter 5, “Troubleshooting”
This chapter provides LED and pinout
information for troubleshooting purposes.
Appendix A, “Site Log”
This provides a site log for tracking the
installation and maintenance activities of the
router.
Document Conventions
This document uses the following conventions:
Convention
Indication
bold font
Commands and keywords and user-entered text appear in bold font.
italic font
Document titles, new or emphasized terms, and arguments for which you supply
values are in italic font.
[ ]
Elements in square brackets are optional.
{x | y | z }
Required alternative keywords are grouped in braces and separated by
vertical bars.
[x|y|z]
Optional alternative keywords are grouped in brackets and separated by
vertical bars.
string
A nonquoted set of characters. Do not use quotation marks around the string or
the string will include the quotation marks.
courier
font
Terminal sessions and information the system displays appear in courier font.
< >
Nonprinting characters such as passwords are in angle brackets.
[ ]
Default responses to system prompts are in square brackets.
!, #
An exclamation point (!) or a pound sign (#) at the beginning of a line of code
indicates a comment line.
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
viii
OL-25178-02
About this Book
Note
Means reader take note.
Tip
Means the following information will help you solve a problem.
Caution
Timesaver
Warning
Means reader be careful. In this situation, you might perform an action that could result in equipment
damage or loss of data.
Means the described action saves time. You can save time by performing the action described in
the paragraph.
Means reader be warned. In this situation, you might perform an action that could result in
bodily injury.
Obtaining Documentation and Submitting a Service Request
For information on obtaining documentation, submitting a service request, and gathering additional
information, see the monthly What’s New in Cisco Product Documentation, which also lists all new and
revised Cisco technical documentation, at:
http://www.cisco.com/en/US/docs/general/whatsnew/whatsnew.html
Subscribe to the What’s New in Cisco Product Documentation as an RSS feed and set content to be
delivered directly to your desktop using a reader application. The RSS feeds are a free service. Cisco currently
supports RSS Version 2.0.
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
OL-25178-02
ix
About this Book
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
x
OL-25178-02
CH A P T E R
1
Cisco ASR 903 Series Aggregation Services
Router Overview
The Cisco ASR 903 Series Aggregation Services Router is a fully-featured aggregation platform
designed for the cost-effective delivery of converged mobile and business services. With shallow depth,
low power consumption, and an extended temperature range, this compact 3-rack-unit (RU) router
provides high service scale, full redundancy, and flexible hardware configuration.
The Cisco ASR 903 Series Aggregation Services Router expands the Cisco service provider product
portfolio by providing a rich and scalable feature set of Layer 2 VPN (L2VPN) and Layer 3 VPN
(L3VPN) services in a compact package. It also supports a variety of software features, including Carrier
Ethernet features, Timing over Packet, and pseudowire.
The Cisco ASR 903 Series Aggregation Services Router is positioned as a pre-aggregation router in IP
RAN (GSM, UMTS, iMAX, CDMA, and LTE) networks or an aggregation router in Carrier Ethernet
networks.
Cisco ASR 903 Series Aggregation Services Router Features
The Cisco ASR 903 Series Aggregation Services Router has the following hardware features:
•
3-RU modular chassis designed for installation in a 300 mm European Telecommunications
Standards Institute (ETSI) cabinet
•
Dedicated slots in the chassis that support the following:
– Up to six interface modules
– Up to two Route Switch Processors (RSP)
– Up to two DC power supply units
– One fan tray
•
Network frequency, phase, and time inputs and outputs for network interfaces (SyncE and TDM),
BITS, 1 PPS or 10 MHz and Timing over Packet (IEEE 1588-2008)
•
Adjustable front and rear rail mounting locations
•
Front panel access to power supplies, fan tray, RSPs, and interface modules
•
Online insertion and removal (OIR) of RSP, interface modules, power supplies, and fan tray
•
Discrete status LEDs on power supply, interface module, RSP, and fan tray units
•
Four alarm dry contact inputs (either normally open or normally closed)
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
OL-25178-02
1-1
Chapter 1
Cisco ASR 903 Series Aggregation Services Router Overview
Cisco ASR 903 Series Aggregation Services Router Features
•
Environmental monitoring and reporting functions
•
LED indicators for critical, major, and minor alarms
•
Side-to-side forced air cooling
•
Temperature range of -40 to 149 degrees F (-40 to 65 degrees C) with DC power supply
Figure 1-1 illustrates the Cisco ASR 903 Series Aggregation Services Router chassis design.
Figure 1-1
Cisco ASR 903 Series Aggregation Services Router Chassis Design
1
GE-0
GE-1
GE-2
2
GE-3
GE-4
GE-5
GE-6
3
GE-7
PWR
FAN TEMP
STAT
GE-0
GE-1
GE-2
GE-3
GE-4
GE-5
GE-6
GE-7
GE-0
GE-1
GE-2
GE-3
GE-4
GE-5
GE-6
GE-7
CRIT MAJ MIN
PWR
STAT
PWR
RUDY RSP
STAT
SYNC
ACT
PWR
MEM
CONSOLE
1PPS
IN
1PPS
OUT
1OMHZ
IN
1OMHZ
OUT
PWR
TOD
BITS
MGMT
ENET
STAT
24V—60V
28A
STAT
L
0
S
L
1
S
L
2
S
L
3
S
L
4
S
L
5
S
L
6
S
L
7 S
L
0
S
L
1
S
L
2
S
L
3
S
L
4
S
L
5
S
L
6
S
L
7 S
L
0
S
L
1
S
L
2
S
L
3
S
L
4
S
L
5
S
L
6
S
L
7 S
PWR
PWR
STAT
INPUT
OK
OUTPUT
FAIL
24V—60V
INPUT
OK
OUTPUT
FAIL
28A
ALARM
281927
STAT
4
1
Interface modules
2
RSP unit
3
Fan tray
4
Redundant power units (two DC power units are shown)
System Specifications
Table 1-1 summarizes the system specifications and environmental requirements for the
Cisco ASR 903 Series Aggregation Services Router.
Table 1-1
Cisco ASR 903 Series Aggregation Services Router System Specifications
Dimensions (Height x Width x Depth)
5.22 in. x17.44 in. x 10.565 in.
(132.588 x 442.976 x 268.351 mm)
Note
Weight
This measurement includes handles from
the power supply, fan tray, and interface
modules installed in the chassis.
27.117 pounds (12.3 kg)
Note
This weight includes a redundant RSP and
power supply.
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
1-2
OL-25178-02
Chapter 1
Cisco ASR 903 Series Aggregation Services Router Overview
Cisco ASR 903 Series Aggregation Services Router Features
Table 1-1
Cisco ASR 903 Series Aggregation Services Router System Specifications
Operating Temperature
The supports the following temperature ranges
with the DC power supply:
•
-60—4000 meters: -40 to 104 degrees F
(-40 to + 40 degrees C)
•
-60—1800 meters: -40 to 149 degrees F
(-40 to + 65 degrees C)
Nonoperating Temperature
-40 to 158 degrees F (-40 to + 70 degrees C)
storage temperature
Operating Humidity
5—95% operating noncondensing relative
humidity
Operating Altitude
Up to 4000 m operating altitude at up to 104
degrees F (40 degrees C) temperature
Nonoperating Altitude
4570 m storage altitude
Operating Vibration
0.41 Grms, 3 to 200 Hz/100 minutes per axis
Sine: 10 to 500 Hz. @ 0.15 G peak 5 sweep
cycles/axis
GR-63-CORE earthquake resistance, Zone 4,
shelf-level
Nonoperating Vibration
Random: 1.15 gRMS 3 to 200 Hz, 30 minutes/axis
Sine: 10 to 500 Hz @ 0.8 G peak / 5 sweep
cycles/axis
Operating Acoustics
< 55 dBa @ 27 degrees C
DC Power Supply
The following sections provide information about the DC power supply for the Cisco ASR 903 Series
Aggregation Services Router:
•
DC Power Specifications, page 1-4
•
DC Power Supply Features, page 1-4
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
OL-25178-02
1-3
Chapter 1
Cisco ASR 903 Series Aggregation Services Router Overview
Cisco ASR 903 Series Aggregation Services Router Features
DC Power Specifications
The Cisco ASR 903 Series Aggregation Services Router uses a +24/-48 Volts Direct Current (VDC) (-19
to -72 VDC supply tolerance) power supply. The power supply provides 550 W output power for system
12 V power. The power supply is field replaceable, hot-swappable, and operates separately from the fan
tray.
The power supply uses a three-position terminal block-style connector with labeled connections for
ground, -24/48 V, and +24/48 V. The power supply contains a front panel with mounting screws, a
handle for insertion and removal, and two status LEDs. No ON/OFF switch is provided.
Table 1-2 summarizes the input power specifications for the Cisco ASR 903 Series Aggregation
Services Router DC power supply.
Table 1-2
DC Power Supply Specifications
Part number
A900-PWR550-D
Input power specification
+24/-48 VDC
Input voltage
-48/-60 VDC
Minimum input voltage
-19.2 VDC
Maximum input voltage
-72 VDC
Minimum output voltage
-36/18 VDC
Maximum output voltage
-72/36 VDC
Wire gauge for DC input power connections
12 AWG minimum for -48/-60 VDC.
8 AWG minimum for 24 VDC.
Connector accepts 8 AWG maximum.
Power dissipation
600 W
DC Power Supply Features
The Cisco ASR 903 Series Aggregation Services Router power supply supports the following features:
•
Redundancy, page 1-4
•
Dying Gasp, page 1-5
•
Status LEDs, page 1-5
For more information about installing the Cisco ASR 903 Series Aggregation Services Router power
supply, see the Installing the Power Supply, page 3-16 section.
Redundancy
The Cisco ASR 903 Series Aggregation Services Router chassis includes a slot for an optional redundant
power supply. The redundant power supply option provides a second, identical power supply to ensure
that power to the chassis continues uninterrupted if one power supply fails or input power on one line
fails. The Cisco ASR 903 Series Aggregation Services Router supports current sharing between the
power supplies.
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
1-4
OL-25178-02
Chapter 1
Cisco ASR 903 Series Aggregation Services Router Overview
Cisco ASR 903 Series Aggregation Services Router Features
If you install a redundant power supply on the Cisco ASR 903 Series Aggregation Services Router, we
recommend that you connect each power supply to a separate input power source in order to ensure that
the router maintains power in the event of a power interruption caused by an electrical failure, a wiring
fault, or a tripped circuit breaker.
Dying Gasp
The Cisco ASR 903 Series Aggregation Services Router supports the Dying Gasp feature, which allows
the router to provide an input power loss notification to the RSP so that the RSP can send appropriate
SNMP traps or OAM messages and update log files on the router. With the DC power supply, the router
supports a minimum input power loss detection time of 2 milliseconds (DC) and continued operation of
at least 6 milliseconds (DC) after the notification.
Note
Continued DC power supply operation may vary for voltages other than +24/-48V.
Status LEDs
LEDs are also provided on each power supply to indicate the status of the input power and the health of
the power supply. For more information about the LEDs on the Cisco ASR 903 Series Aggregation
Services Router, see Chapter 5, “Troubleshooting.”
Fan Tray
The Cisco ASR 903 Series Aggregation Services Router uses a modular fan tray that is separate from
the power supply. The fan tray contains twelve fans and provides sufficient capacity to maintain
operation indefinitely in the event of an individual fan failure.
The fan tray has the following hardware features:
•
It provides side-to-side forced air cooling
•
It provides redundant fans
•
It is field replaceable
•
It contains status LEDs
•
It contains an alarm port with four external alarm inputs
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
OL-25178-02
1-5
Chapter 1
Cisco ASR 903 Series Aggregation Services Router Overview
Cisco ASR 903 Series Aggregation Services Router Features
Figure 1-2 shows the fan tray.
Figure 1-2
Cisco ASR 903 Series Aggregation Services Router Fan Tray
FAN TEMP
CRIT MAJ MIN
281933
ALARM
For instructions on how to install the fan tray, see Installing the Fan Tray, page 3-8. For a summary of
the LEDs on the fan tray, see “LED Summary” section on page 5-7.
RSP Modules
The Cisco ASR 903 Series Aggregation Services Router is designed to use up to two RSP modules to
handle the data plane, network timing, and control plane functionalities for the router. The RSP
configuration allows you to use Cisco IOS software to control chassis management, redundancy, external
management, and system status indications on the router.
The following sections describe the Cisco ASR 903 Series Aggregation Services Router RSP:
•
Supported RSP Features, page 1-7
•
RSP Redundancy, page 1-7
•
Network Timing Interfaces, page 1-8
•
RSP Interfaces, page 1-8
RSP features include:
•
Loading software onto processor-based interface modules
•
Redundant RSP management—The RSP manages detection of RSPs, exchange of health and status
information, role negotiation, function for detection, health and status exchange, role negotiation
•
Packet processing
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
1-6
OL-25178-02
Chapter 1
Cisco ASR 903 Series Aggregation Services Router Overview
Cisco ASR 903 Series Aggregation Services Router Features
•
Traffic management, including buffering, queuing, and scheduling, Ethernet MAC functions
•
Network clocking functions including phase and time-of-day for BITS, 1 PPS, 10 MHz, and 1588
PTP clock references.
•
Storage of software images, system configuration, OBFL, SysLog
•
PTP packet processing including IEEE 1588-2008 for recovering network timing (frequency, phase,
and time) from upstream PTP clocks, for generating PTP frequency and phase references as inputs
to the SETS, and for distributing them to downstream PTP clocks
•
External management interfaces (RS232 console, management ENET, USB console, USB storage)
and system status LED indicators
Supported RSPs
The Cisco ASR 903 Series Aggregation Services Router supports the following RSPs:
Note
•
A900-RSP1A-55—Provides 2 GB of SDRAM, 5 Mb of TCAM memory, 3-Mb buffer table,
576-Mb forwarding memory, and 1,536-Mb packet buffer memory.
•
A900-RSP1B-55—Provides 4 GB of SDRAM, 20 Mb of TCAM memory, 144-Mb buffer table,
1152-Mb forwarding memory, and 1,536-Mb packet buffer memory.
The supported RSPs have different memory capacities, but they have the same interfaces and
functionality.
Supported RSP Features
The RSP provides the following features on the Cisco router:
•
Centralized data plane, timing, and control plane functions for the system
•
High-level control of interface modules
•
Management functionalities for the router
•
Control plane (host) CPU and associated memory in which IOS-XE and platform control software
runs
•
Nonvolatile memory for storage of software images, configurations, and system files
•
Enabling and monitoring the health and presence of fan trays, interface modules, and power supplies
•
Field replacement and hot-swap capabilities
RSP Redundancy
The Cisco ASR 903 Series Aggregation Services Router chassis includes two RSP slots to allow for
redundant RSPs. When the router uses redundant RSPs, one RSP operates in the active mode and the
other operates in the hot standby mode. Removal or failure of the active RSP results in an automatic
switchover to the standby RSP.
Note
If you are using redundant RSPs, both the RSPs must be of the same type because a mixed configuration
of two different RSP types is not supported.
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
OL-25178-02
1-7
Chapter 1
Cisco ASR 903 Series Aggregation Services Router Overview
Cisco ASR 903 Series Aggregation Services Router Features
Network Timing Interfaces
The RSP supports the following network timing interfaces:
•
BITS input/output port—RJ48 jack
•
1 PPS input and output—Mini coax connectors
•
2.048 or 10 MHz input and output—Mini coax connectors
•
Time of Day (ToD) or 1 PPS input or output port—Shielded RJ45 jack
Network timing interfaces support redundancy in a redundant RSP configuration. Network timing
interfaces on a redundant RSP remain in operation while the RSP is in hot standby mode.
RSP Interfaces
Figure 1-3 summarizes the interfaces on the RSP module.
Figure 1-3
RSP Interfaces Summary
1
2
3
4
5
6
7
8
9
10
RUDY RSP
SYNC
ACT
CONSOLE
1PPS
OUT
1OMHZ
IN
1OMHZ
OUT
PWR
TOD
BITS
MGMT
ENET
STAT
281931
MEM
1PPS
IN
Label
Interface
1
USB memory port
2
USB console port
3
Console port
4
1 PPS input timing port
5
1 PPS output timing port
6
10 MHz input timing port
7
10 MHz output timing port
8
Time of Day (ToD) timing port
9
BITS timing port
10
Ethernet management port
For more information about installing the RSP, see RSP Installation, page 3-10. For more information
about the RSP LEDs, see RSP LEDs, page 5-7.
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
1-8
OL-25178-02
Chapter 1
Cisco ASR 903 Series Aggregation Services Router Overview
Cisco ASR 903 Series Aggregation Services Router Features
Interface Modules
In addition to the ports provided on an RSP, the Cisco ASR 903 Series Aggregation Services Router
supports the following interface modules:
Note
•
Gigabit Ethernet SFP Interface Module, page 1-9
•
Gigabit Ethernet RJ45 Interface Module, page 1-10
•
10 Gigabit Ethernet XFP Interface Module, page 1-11
•
T1/E1 Interface Module, page 1-12
•
OC-3 Interface Module, page 1-13
For information about supported interface modules, see the Release Notes for the Cisco ASR 903 Series
Aggregation Services Router.
Gigabit Ethernet SFP Interface Module
The Gigabit Ethernet Small Form-Factor Pluggable (SFP) interface module provides eight Gigabit
Ethernet SFP modules. Figure 1-4 shows the 8 x 1 GE Gigabit Ethernet SFP interface module.
8 x 1 GE Gigabit Ethernet SFP Interface Module
282440
Figure 1-4
Supported SFP Modules
The Gigabit Ethernet SFP interface module supports the following SFP modules:
•
1000M - CWDM-SFP
•
1000M - DWDM-SFP
•
10G BX-D
•
10G BX-U
•
10G C-BAND T-DWDM
•
10GER-OC192IR-RGD
•
10GLR-OC192SR-RGD
•
10G-MM-SR
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
OL-25178-02
1-9
Chapter 1
Cisco ASR 903 Series Aggregation Services Router Overview
Cisco ASR 903 Series Aggregation Services Router Features
•
10GZR-OC192LR-RGD
•
GLC-BX-D
•
GLC-BX-U
•
GLC-EX-SMD
•
GLC-FE-100FX-RGD
•
GLC-FE-100LX-RGD
•
GLC-LH-SMD
•
GLC-LH-SM-RGD
•
GLC-SX-MMD
•
GLC-SX-MM-RGD
•
GLC-TE
•
GLC-ZX-SMD
•
GLC-ZX-SM-RGD
•
SFP-GE-T
For more information about installing a SFP Gigabit Ethernet module, see the “Interface Module
Installation” section on page 3-14.
Gigabit Ethernet RJ45 Interface Module
The Gigabit Ethernet RJ45 interface module provides eight Gigabit Ethernet copper ports. Figure 1-5
shows the interface module.
8 x 1 GE Gigabit Ethernet RJ45 (Copper) Interface Module
282439
Figure 1-5
For more information about installing an RJ45 Gigabit Ethernet module, see the “Interface Module
Installation” section on page 3-14.
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
1-10
OL-25178-02
Chapter 1
Cisco ASR 903 Series Aggregation Services Router Overview
Cisco ASR 903 Series Aggregation Services Router Features
10 Gigabit Ethernet XFP Interface Module
The 10 Gigabit Ethernet XFP interface module provides a single port supporting a 10 Gigabit Ethernet
XFP module. Figure 1-6 shows the interface module.
1 x 10 GE Gigabit Ethernet XFP Interface Module
282437
Figure 1-6
For more information about installing a 10GE XFP module, see the “Interface Module Installation”
section on page 3-14.
Note
10 Gigabit Ethernet interface modules are not supported in slots 4 and 5.
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
OL-25178-02
1-11
Chapter 1
Cisco ASR 903 Series Aggregation Services Router Overview
Cisco ASR 903 Series Aggregation Services Router Features
T1/E1 Interface Module
The T1/E1 interface module provides connectivity for up to 16 T1/E1 ports through a 100-pin Amplimite
connector. The T1/E1 interface module requires the use of a patch panel to provide RJ48 (T1) or BNC
(E1) connectors. Figure 1-7 shows the interface module.
16 x T1/E1 Interface Module
282441
Figure 1-7
For more information about installing a T1/E1 interface module, see the “Interface Module Installation”
section on page 3-14.
OC-3 Interface Module
The OC-3 interface module can operate as up to four STM-1 interfaces.
Note
The optical interface module is designed for OC-3 and OC-12 traffic, but OC-12 functionality is not
currently supported.
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
1-12
OL-25178-02
Chapter 1
Cisco ASR 903 Series Aggregation Services Router Overview
Cisco ASR 903 Series Aggregation Services Router Features
Figure 1-8 shows the interface module.
4 x OC-3 Interface Module
282438
Figure 1-8
For more information about installing an optical interface module, see the “Interface Module
Installation” section on page 3-14.
Temperature Sensor
The Cisco ASR 903 Series Aggregation Services Router has a temperature sensor to detect
overtemperature conditions inside the chassis. The overtemperature detection trips at 75 degrees C +/5% with the ambient (inlet) trip point at 67 degrees C. This condition is reported to the processor as an
interrupt, and the software takes action to generate the appropriate alarms.
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
OL-25178-02
1-13
Chapter 1
Cisco ASR 903 Series Aggregation Services Router Overview
Interface Numbering
Serial Number Label Location
Figure 1-9 shows the serial number label location on the Cisco ASR 903 Series Aggregation Services
Router.
Figure 1-9
Cisco ASR 903 Series Aggregation Services Router Serial Number Location
11 letters and numbers
282407
Serial Number
Interface Numbering
The Cisco ASR 903 Series Aggregation Services Router chassis includes:
•
Six interface module slots
•
Two RSP module slots
•
Two power supply slots
•
One fan tray slot
Each network interface on a Cisco ASR 903 Series Aggregation Services Router is identified by a slot
number and a port number.
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
1-14
OL-25178-02
Chapter 1
Cisco ASR 903 Series Aggregation Services Router Overview
Regulatory Compliance
Figure 1-10 shows interface numbering in a Cisco ASR 903 Series Aggregation Services Router.
Figure 1-10
Cisco ASR 903 Series Aggregation Services Router Slot Numbers
1
GE-0
GE-1
GE-2
GE-3
GE-4
GE-5
GE-6
2
3
GE-7
11
PWR
RUDY RSP
FAN TEMP
SYNC
STAT
ACT
GE-0
GE-1
GE-2
GE-3
GE-4
GE-5
GE-6
GE-7
GE-0
GE-1
GE-2
GE-3
GE-4
GE-5
GE-6
GE-7
10
PWR
MEM
CONSOLE
1PPS
IN
MEM
CONSOLE
1PPS
IN
PWR
1PPS
OUT
1OMHZ
IN
1OMHZ
OUT
TOD
BITS
MGMT
ENET
1PPS
OUT
1OMHZ
IN
1OMHZ
OUT
TOD
BITS
MGMT
ENET
STAT
24V—60V
28A
CRIT MAJ MIN
STAT
STAT
9
PWR
8
PWR
RUDY RSP
STAT
SYNC
ACT
6
L
0
S
L
1
S
L
2
S
L
3
S
L
4
S
L
5
S
L
6
S
L
7 S
L
0
S
L
1
S
L
2
S
L
3
S
L
4
S
L
5
S
L
6
S
L
7 S
L
0
S
L
1
S
L
2
S
L
3
S
L
4
S
L
5
S
L
6
S
L
7 S
PWR
PWR
STAT
PWR
STAT
INPUT
OK
OUTPUT
FAIL
24V—60V
INPUT
OK
OUTPUT
FAIL
28A
ALARM
5
1
RSP slot 1
2
RSP slot 0
3
Fan tray slot
4
Power supply slot 1
5
Power supply slot 0
6
Interface module slot 0
7
Interface module slot 1
8
Interface module slot 2
9
Interface module slot 3
10
Interface module slot 4
11
Interface module slot 5
209290
7
STAT
4
Following is an explanation of the slot or port numbering:
•
The numbering format is Interface type slot or interface number. Interface (port) numbers begin at
logical 0 for each interface type.
•
Interface module slots are numbered from bottom to top, with logical interfaces on each module
numbered from left to right. Interfaces are hard-wired. Therefore, port 0 is always logical interface
0/0, port 1 is always logical interface 0/1, and so on.
Regulatory Compliance
For regulatory compliance and safety information, see the Regulatory Compliance and Safety
Information for the Cisco ASR 903 Series Aggregation Services Router document.
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
OL-25178-02
1-15
Chapter 1
Cisco ASR 903 Series Aggregation Services Router Overview
Regulatory Compliance
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
1-16
OL-25178-02
CH A P T E R
2
Preparing for Installation
The following sections describe how to prepare for the installation of the Cisco ASR 903 Series
Aggregation Services Router at your site:
•
Safety Guidelines, page 2-1
•
Site Planning, page 2-9
•
Receiving the Cisco ASR 903 Series Aggregation Services Router, page 2-18
Safety Guidelines
Before you begin the installation of the Cisco ASR 903 Series Aggregation Services Router, review the
safety guidelines in this chapter to avoid injuring yourself or damaging the equipment.
In addition, before replacing, configuring, or maintaining the Cisco ASR 903 Series Aggregation
Services Router, review the safety warnings listed in Regulatory Compliance and Safety Information for
the Cisco ASR 903 Series Aggregation Services Router.
The following sections describe the safety guidelines for the Cisco ASR 903 Series Aggregation
Services Router:
•
Standard Warning Statements, page 2-2
•
Safety Guidelines for Personal Safety and Equipment Protection, page 2-3
•
Safety Precautions for Module Installation and Removal, page 2-3
•
Safety with Electricity, page 2-4
•
Power Supply Considerations, page 2-8
•
Preventing ESD Damage, page 2-8
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
OL-25178-02
2-1
Chapter 2
Preparing for Installation
Safety Guidelines
Standard Warning Statements
To see translations of the warnings that appear in this publication, refer to the Regulatory Compliance
and Safety Information document that accompanied this device.
Warning
To prevent bodily injury when mounting or servicing this unit in a rack, you must take special
precautions to ensure that the system remains stable. The following guidelines are provided to ensure
your safety: This unit should be mounted at the bottom of the rack if it is the only unit in the rack. When mounting
this unit in a partially filled rack, load the rack from the bottom to the top with the heaviest component at the bottom
of the rack. If the rack is provided with stabilizing devices, install the stabilizers before mounting or servicing the unit
in the rack. Statement 1006
Warning
This unit is intended for installation in restricted access areas. A restricted access area can be
accessed only through the use of a special tool, lock and key, or other means of security.
Statement 1017
Warning
Ultimate disposal of this product should be handled according to all national laws and regulations.
Statement 1040
Warning
To prevent the system from overheating, do not operate it in an area that exceeds the maximum
recommended ambient temperature of 149°F (65°C). Statement 1047
Warning
The chassis should be mounted on a rack that is permanently affixed to the building. Statement 1049
Warning
IMPORTANT SAFETY INSTRUCTIONS: This warning symbol means danger. You are in a situation that
could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with
electrical circuitry and be familiar with standard practices for preventing accidents. Use the
statement number provided at the end of each warning to locate its translation in the translated safety
warnings that accompanied this device. Statement 1071
Warning
This is a Class A Device and is registered for EMC requirements for industrial use. The seller or buyer
should be aware of this. If this type was sold or purchased by mistake, it should be replaced with a
residential-use type. Statement 294
Warning
This is a class A product. In a domestic environment this product may cause radio interference in
which case the user may be required to take adequate measures. Statement 340
Warning
This equipment is in compliance with the essential requirements and other relevant provisions of
Directive 1999/5/EC.
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
2-2
OL-25178-02
Chapter 2
Preparing for Installation
Safety Guidelines
Safety Guidelines for Personal Safety and Equipment Protection
The following guidelines help ensure your safety and protect the equipment. This list does not include
all the potentially hazardous situations. Therefore, you should be on alert.
•
Before moving the system, always disconnect all the power cords and interface cables.
•
Never assume that power is disconnected from a circuit; always check.
•
Before and after installation, keep the chassis area clear and dust-free.
•
Keep tools and assembly components away from walk areas where you or others could trip over
them.
•
Do not work alone if potentially hazardous conditions exist.
•
Do not perform any action that creates a potential hazard to people or makes the equipment unsafe.
•
Do not wear loose clothing that may get caught in the chassis.
•
When working under conditions that may be hazardous to your eyes, wear safety glasses.
Safety Precautions for Module Installation and Removal
Be sure to observe the following safety precautions when you work on the router.
To see translations of the warnings that appear in this publication, refer to the Regulatory Compliance
and Safety Information document that accompanied this device.
Warning
Class 1 laser product. Statement 1008
Warning
Do not stare into the beam or view it directly with optical instruments. Statement 1011
Warning
Invisible laser radiation present. Statement 1016
Warning
Hazardous network voltages are present in WAN ports regardless of whether power to the unit is OFF
or ON. To avoid electric shock, use caution when working near WAN ports. When detaching cables,
detach the end away from the unit first. Statement 1026
Warning
Blank faceplates and cover panels serve three important functions: they prevent exposure to
hazardous voltages and currents inside the chassis; they contain electromagnetic interference (EMI)
that might disrupt other equipment; and they direct the flow of cooling air through the chassis. Do not
operate the system unless all cards, faceplates, front covers, and rear covers are in place.
Statement 1029
Warning
Hazardous voltage or energy is present on the backplane when the system is operating. Use caution
when servicing. Statement 1034
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
OL-25178-02
2-3
Chapter 2
Preparing for Installation
Safety Guidelines
Warning
Invisible laser radiation may be emitted from disconnected fibers or connectors. Do not stare into
beams or view directly with optical instruments. Statement 1051
Safety with Electricity
Warning
Before working on a chassis or working near power supplies, unplug the power cord on AC units;
disconnect the power at the circuit breaker on DC units. Statement 12
Warning
Before working on equipment that is connected to power lines, remove jewelry (including rings,
necklaces, and watches). Metal objects will heat up when connected to power and ground and can
cause serious burns or weld the metal object to the terminals. Statement 43
Warning
Do not work on the system or connect or disconnect cables during periods of lightning activity.
Statement 1001
Warning
Before performing any of the following procedures, ensure that power is removed from the DC circuit.
Statement 1003
Warning
Read the installation instructions before connecting the system to the power source. Statement 1004
Warning
This product relies on the building’s installation for short-circuit (overcurrent) protection. Ensure that
the protective device is rated: For a -48/-60 VDC installation, the wire shall be 12 AWG minimum with
a 20 A branch circuit breaker. For a 24 VDC installation, the wire shall be 8 AWG minimum with a 40
A branch circuit breaker. Statement 1005
Warning
There is the danger of explosion if the battery is replaced incorrectly. Replace the battery only with
the same or equivalent type recommended by the manufacturer. Dispose of used batteries according
to the manufacturer’s instructions. Statement 1015
Warning
This unit is intended for installation in restricted access areas. A restricted access area can be
accessed only through the use of a special tool, lock and key, or other means of security.
Statement 1017
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
2-4
OL-25178-02
Chapter 2
Preparing for Installation
Safety Guidelines
Warning
When you connect or disconnect the power and relay connector with power applied, an electrical arc
can occur. This could cause an explosion in hazardous area installations. Be sure that power is
removed from the switch and alarm circuit. Be sure that power cannot be accidentally turned on or
verify that the area is nonhazardous before proceeding. Failure to securely tighten the power and
relay connector captive screws can result in an electrical arc if the connector is accidentally
removed. Statement 1058
Warning
Take care when connecting units to the supply circuit so that wiring is not overloaded. Statement 1018
Warning
The plug-socket combination must be accessible at all times, because it serves as the main
disconnecting device. Statement 1019
Warning
To avoid electric shock, do not connect safety extra-low voltage (SELV) circuits to telephone-network
voltage (TNV) circuits. LAN ports contain SELV circuits, and WAN ports contain TNV circuits. Some
LAN and WAN ports both use RJ45 connectors. Use caution when connecting cables. Statement 1021
Warning
A readily accessible two-poled disconnect device must be incorporated in the fixed wiring. Statement
1022
Warning
To reduce the risk of fire, use only 26 AWG or larger telecommunication line cord. Statement 1023
Warning
This equipment must be grounded. Never defeat the ground conductor or operate the equipment in the
absence of a suitably installed ground conductor. Contact the appropriate electrical inspection
authority or an electrician if you are uncertain that suitable grounding is available. Statement 1024
Warning
Use copper conductors only. Statement 1025
Warning
This unit might have more than one power supply connection. All connections must be removed to
de-energize the unit. Statement 1028
Warning
To prevent personal injury or damage to the chassis, never attempt to lift or tilt the chassis using the
handles on modules (such as power supplies, fans, or cards); these types of handles are not designed
to support the weight of the unit. Statement 1032
Warning
Connect the unit only to DC power source that complies with the safety extra-low voltage (SELV)
requirements in IEC 60950 based safety standards. Statement 1033
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
OL-25178-02
2-5
Chapter 2
Preparing for Installation
Safety Guidelines
Warning
Do not use this product near water; for example, near a bath tub, wash bowl, kitchen sink or laundry
tub, in a wet basement, or near a swimming pool. Statement 1035
Warning
Never install telephone jacks in wet locations unless the jack is specifically designed for
wet locations. Statement 1036
Warning
Before opening the unit, disconnect the telephone-network cables to avoid contact with
telephone-network voltages. Statement 1041
Warning
This equipment must be installed and maintained by service personnel as defined by AS/NZS 3260.
Incorrectly connecting this equipment to a general-purpose outlet could be hazardous. The
telecommunications lines must be disconnected 1) before unplugging the main power connector or 2)
while the housing is open, or both. Statement 1043
Warning
This product requires short-circuit (overturned) protection, to be provided as part of the building
installation. Install only in accordance with national and local wiring regulations. Statement 1045
Warning
When installing or replacing the unit, the ground connection must always be made first and
disconnected last. Statement 1046
Warning
Never install an AC power module and a DC power module in the same chassis. Statement 1050
Warning
Failure to securely tighten the power and relay connector captive screws can result in an electrical
arc if the connector is accidentally removed. Statement 1058
Warning
This equipment is intended to be grounded. Ensure that the host is connected to earth ground during
normal use.
Warning
If you connect or disconnect the console cable with power applied to the switch or any device on the
network, an electrical arc can occur. This could cause an explosion in hazardous location
installations. Be sure that power is removed or the area is nonhazardous before proceeding. To verify
switch operation, perform POST on the switch in a nonhazardous location before installation.
Statement 1065
Warning
Installation of the equipment must comply with local and national electrical codes. Statement 1074
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
2-6
OL-25178-02
Chapter 2
Preparing for Installation
Safety Guidelines
Warning
Hazardous voltage or energy may be present on DC power terminals. Always replace cover when
terminals are not in service. Be sure uninsulated conductors are not accessible when cover is in
place. Statement 1075
When working on equipment powered by electricity, follow these guidelines:
•
Locate the room’s emergency power-off switch. If an electrical accident occurs, you will be able to
quickly turn off the power.
•
Before working on the system, turn off the DC main circuit breaker and disconnect the power
terminal block cable.
•
Before doing the following, disconnect all power:
– Working on or near power supplies
– Installing or removing a router chassis or network processor module
– Performing most hardware upgrades
•
Never install equipment that appears damaged.
•
Carefully examine your work area for possible hazards, such as moist floors, ungrounded power
extension cables, and missing safety grounds.
•
Never assume that power is disconnected from a circuit; always check.
•
Never perform any action that creates a potential hazard to people or makes the equipment unsafe.
•
If an electrical accident occurs, proceed as follows:
– Use caution, and do not become a victim yourself.
– Turn off power to the router.
– If possible, send another person to get medical aid. Otherwise, determine the condition of the
victim, and then call for help.
– Determine whether the person needs rescue breathing or external cardiac compressions; then
take appropriate action.
In addition, use the following guidelines when working with any equipment that is disconnected from a
power source, but still connected to telephone wiring or network cabling:
•
Never install telephone wiring during a lightning storm.
•
Never install telephone jacks in wet locations unless the jack is specifically designed for it.
•
Never touch uninsulated telephone wires or terminals unless the telephone line is disconnected at
the network interface.
•
When installing or modifying telephone lines, use caution.
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
OL-25178-02
2-7
Chapter 2
Preparing for Installation
Safety Guidelines
Power Supply Considerations
Check the power at your site to ensure that you are receiving clean power (free of spikes and noise).
Install a power conditioner if necessary.
Warning
This equipment is designed for connection to TN and IT power systems. Statement 16
Preventing ESD Damage
Warning
This equipment needs to be grounded. Use a green and yellow 6 AWG ground wire to connect the host
to earth ground during normal use. Statement 383
Electrostatic discharge (ESD) can damage equipment and impair electrical circuitry. ESD can occur
when electronic printed circuit cards are improperly handled and can cause complete or intermittent
failures. When removing and replacing modules, always follow ESD prevention procedures:
Note
•
Ensure that the router chassis is electrically connected to earth ground.
•
Wear an ESD-preventive wrist strap, ensuring that it makes good skin contact. To channel unwanted
ESD voltages safely to ground, connect the clip to an unpainted surface of the chassis frame. To
guard against ESD damage and shocks, the wrist strap and cord must operate effectively.
•
If no wrist strap is available, ground yourself by touching a metal part of the chassis.
•
When installing a component, use any available ejector levers or captive installation screws to
properly seat the bus connectors in the backplane or midplane. These devices prevent accidental
removal, provide proper grounding for the system, and help to ensure that bus connectors are
properly seated.
•
When removing a component, use available ejector levers or captive installation screws, if any, to
release the bus connectors from the backplane or midplane.
•
Handle components by their handles or edges only; do not touch the printed circuit boards or
connectors.
•
Place a removed component board side up on an antistatic surface or in a static-shielding container.
If you plan to return the component to the factory, immediately place it in a static-shielding
container.
•
Avoid contact between the printed circuit boards and clothing. The wrist strap only protects
components from ESD voltages on the body; ESD voltages on clothing can still cause damage.
•
Never attempt to remove the printed circuit board from the metal carrier.
For the safety of your equipment, periodically check the resistance value of the antistatic wrist strap. It
should be between 1 and 10 Mohm.
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
2-8
OL-25178-02
Chapter 2
Preparing for Installation
Site Planning
Site Planning
The following sections describe how to plan for the installation of the Cisco ASR 903 Series Aggregation
Services Router:
•
General Precautions, page 2-9
•
Site Planning Checklist, page 2-9
•
Site Selection Guidelines, page 2-10
•
Air Flow Guidelines, page 2-10
•
Floor Loading Considerations, page 2-11
•
Site Power Guidelines, page 2-11
•
Site Cabling Guidelines, page 2-12
•
Rack-Mounting Guidelines, page 2-14
•
Installation Checklist, page 2-17
•
Creating a Site Log, page 2-18
General Precautions
Observe the following general precautions when using and working with your Cisco ASR 903 Series
Aggregation Services Router system:
•
Keep your system components away from radiators and heat sources and do not block cooling vents.
•
Do not spill food or liquids on your system components and never operate the product in a wet
environment.
•
Do not push any objects into the openings of your system components. Doing so can cause fire or
electric shock by shorting out interior components.
•
Position system cables and power supply cables carefully. Route system cables and the power supply
cable and plug so that they cannot be stepped on or tripped over. Be sure that nothing else rests on
your system component cables or power cable.
•
Do not modify power cables or plugs. Consult a licensed electrician or your power company for site
modifications. Always follow your local and national wiring rules.
•
If you turn off your system, wait at least 30 seconds before turning it on again to avoid system
component damage.
Site Planning Checklist
Use the following checklist to perform and account for all the site planning tasks described in this
chapter:
•
The site meets the environmental requirements.
•
The site’s air conditioning system can compensate for the heat dissipation of the Cisco ASR 903
Series Aggregation Services Router.
•
The floor space that the Cisco ASR 903 Series Aggregation Services Router occupies can support
the weight of the system.
•
Electrical service to the site complies with the requirements.
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
OL-25178-02
2-9
Chapter 2
Preparing for Installation
Site Planning
•
The electrical circuit servicing the Cisco ASR 903 Series Aggregation Services Router complies
with the requirements.
•
Consideration has been given to the console port wiring and limitations of the cabling involved,
according to TIA/EIA-232F.
•
The Cisco ASR 903 Series Aggregation Services Router Ethernet cabling distances are within
limitations.
•
The equipment rack in which you plan to install the Cisco ASR 903 Series Aggregation Services
Router complies with requirements.
•
In selecting the location of the rack, careful consideration has been given to safety, ease of
maintenance, and proper airflow.
Site Selection Guidelines
The Cisco ASR 903 Series Aggregation Services Router requires specific environmental operating
conditions. Temperature, humidity, altitude, and vibration can affect the performance and reliability of
the router. The following sections provide specific information to help you plan for the proper operating
environment.
The Cisco ASR 903 Series Aggregation Services Router is designed to meet the industry EMC, safety,
and environmental standards described in the Regulatory, Safety, and Compliance Information for the
Cisco ASR 903 Series Aggregation Services Router.
Environmental Requirements
Environmental monitoring in the Cisco ASR 903 Series Aggregation Services Router protects the system
and components from damage caused by excessive voltage and temperature conditions. To ensure normal
operation and avoid unnecessary maintenance, plan and prepare your site configuration before
installation. After installation, make sure that the site maintains the environmental characteristics
described in “System Specifications” section on page 2.
Physical Characteristics
Be familiar with the physical characteristics of the Cisco ASR 903 Series Aggregation Services Router
to assist you in placing the system in the proper location. For more information, see the “System
Specifications” section on page 2.
Air Flow Guidelines
The following guidelines will help you plan your equipment rack configuration:
•
To ensure adequate air flow through the equipment rack, we recommend that you maintain a
clearance of at least 80 mm on each side of the rack at all times.
•
If airflow through the equipment rack and the routers that occupy it is blocked or restricted, or if the
ambient air being drawn into the rack is too warm, an overtemperature condition can occur within
the rack and the routers that occupy it.
•
The site should also be as dust-free as possible. Dust tends to clog the router fans, reducing the flow
of cooling air through the equipment rack and the routers that occupy it, thus increasing the risk of
an overtemperature condition.
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
2-10
OL-25178-02
Chapter 2
Preparing for Installation
Site Planning
•
Enclosed racks must have adequate ventilation. Ensure that the rack is not congested, because each
router generates heat. An enclosed rack should have louvered sides and a fan to provide cooling air.
Heat that is generated by the equipment near the bottom of the rack can be drawn upward into the
intake ports of the equipment above.
•
When mounting a chassis in an open rack, ensure that the rack frame does not block the side intakes
and the exhaust fans.
•
When rack-installed equipment fails, especially equipment in an enclosed rack, try operating the
equipment by itself, if possible. Power off all other equipment in the rack (and in adjacent racks) to
give the router maximum cooling air and clean power.
•
Avoid locating the Cisco ASR 903 Series Aggregation Services Router in a location in which the
chassis air intake vents may draw in the exhaust air from adjacent equipment. Consider how the air
flows through the Cisco ASR 903 Series Aggregation Services Router. The Cisco ASR 903 Series
Aggregation Services Router airflow direction is side to side, with ambient air drawn in from the
vents located on the front right of the chassis.
Floor Loading Considerations
Ensure that the floor under the rack supporting the Cisco ASR 903 Series Aggregation Services Routers
is capable of supporting the combined weight of the rack and all the other installed equipment.
To assess the weight of a fully configured Cisco ASR 903 Series Aggregation Services Router, refer to
“System Specifications” section on page 1-2.
For additional information about floor loading requirements, consult GR-63-CORE, Network Equipment
Building System (NEBS) Requirements: Physical Protection.
Site Power Guidelines
The Cisco ASR 903 Series Aggregation Services Router has specific power and electrical wiring
requirements. Adhering to these requirements ensures reliable operation of the system. Follow these
precautions and recommendations when planning your site power for the Cisco ASR 903 Series
Aggregation Services Router:
Caution
•
The redundant power option provides a second, identical power supply to ensure that power to the
chassis continues uninterrupted if one power supply fails or input power on one line fails.
•
In systems configured with the redundant power option, connect each of the two power supplies to
a separate input power source. If you fail to do this, your system might be susceptible to total power
failure due to a fault in the external wiring or a tripped circuit breaker.
•
To prevent a loss of input power, be sure that the total maximum load on each circuit supplying the
power supplies is within the current ratings of the wiring and the breakers.
•
Check the power at your site before installation and periodically after installation to ensure that you
are receiving clean power. Install a power conditioner if necessary.
•
Provide proper grounding to avoid personal injury and damage to the equipment due to lightning
striking power lines or due to power surges. The chassis ground must be attached to a central office
or other interior ground system.
This product requires short-circuit (overcurrent) protection, to be provided as part of the building
installation. Install only in accordance with national and local wiring regulations.
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
OL-25178-02
2-11
Chapter 2
Preparing for Installation
Site Planning
Note
The Cisco ASR 903 Series Aggregation Services Router installation must comply with all the applicable
codes and is approved for use with copper conductors only. The ground bond fastening hardware should
be of compatible material and preclude loosening, deterioration, and electrochemical corrosion of
hardware and joined material. Attachment of the chassis ground to a central office or other interior
ground system must be made with a 6 AWG gauge wire, copper ground conductor at a minimum.
The maximum power draw of the Cisco ASR 903 Series Aggregation Services Router chassis and its
configurable hardware components are listed in the following table. The maximum power draw values
are not affected by whether the router chassis contains 1 or 2 power supplies AC or DC.
Hardware component(s)
Maximum power draw value
Router chassis with 2 power supplies, 1 fan tray, and 1 RSP1A
195 W
Router chassis with 2 power supplies, 1 fan tray, and 1 RSP1B
210 W
A900-RSP1A-55 (standby)
100 W
A900-RSP1B-55 (standby)
100 W
A900-IMA1X (1-port 10 GE XFP interface module)
13.0 W
A900-IMA8T (8-port 1 GE RJ45 interface module)
17.5 W
A900-IMA8S (8-port 1 GE SFP interface module)
17.5 W
A900-IMA16D (16-port T1/E1 interface module)
14.5 W
Electrical Circuit Requirements
Each Cisco ASR 903 Series Aggregation Services Router requires a dedicated electrical circuit. If you
equip it with dual power feeds, provide a separate circuit for each power supply to avoid compromising
the power redundancy feature.
The Cisco ASR 903 Series Aggregation Services Routers can be powered by a DC source or an AC
source. Ensure that equipment grounding is present and observe the power strip ratings. Make sure that
the total ampere rating of all products plugged into the power strip does not exceed 80% of the rating.
For more information about the Cisco ASR 903 Series Aggregation Services Router power supply, see
the “DC Power Supply” section on page 1-3.
Site Cabling Guidelines
This section contains guidelines for wiring and cabling at your site. When preparing your site for
network connections to the Cisco ASR 903 Series Aggregation Services Router, consider the type of
cable required for each component, and the cable limitations. Consider the distance limitations for
signaling, electromagnetic interference (EMI), and connector compatibility. Possible cable types are
fiber, thick or thin coaxial, foil twisted-pair, or unshielded twisted-pair cabling.
Also consider any additional interface equipment you need, such as transceivers, hubs, switches,
modems, channel service units (CSU), or data service units (DSU).
Before you begin, read these important notes about cabling:
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
2-12
OL-25178-02
Chapter 2
Preparing for Installation
Site Planning
•
The T1/E1 interface module for the Cisco ASR 903 Series Aggregation Services Router uses a
high-density connector that requires the use of a T1/E1 interface cable and a customer-provided
patch panel. For more information, see “Connecting T1/E1 cables” section on page 3-34.
•
Shielded cables must be used to connect to the DB-25 alarm connector on the fan tray in order to
comply with FCC/EN55022/CISPR22 Class A emissions requirements. For information about the
fan tray alarm port, see “Connecting the Fan Tray Alarm Port” section on page 3-37.
Before you install the Cisco ASR 903 Series Aggregation Services Router, have all the additional
external equipment and cables on hand. For information about ordering, contact a Cisco customer
service representative.
The extent of your network and the distances between the network interface connections depend in part
on the following factors:
•
Signal type
•
Signal speed
•
Transmission medium
The distance and rate limits referenced in the following sections are the IEEE-recommended maximum
speeds and distances for signaling purposes. Use this information as a guideline in planning your
network connections prior to installing the Cisco ASR 903 Series Aggregation Services Router.
If wires exceed the recommended distances, or if wires pass between buildings, give special
consideration to the effect of a lightning strike in your vicinity. The electromagnetic pulse caused by
lightning or other high-energy phenomena can easily couple enough energy into unshielded conductors
to destroy electronic devices. If you have had problems of this sort in the past, you may want to consult
experts in electrical surge suppression and shielding.
Asynchronous Terminal Connections
The RSP provides a console port to connect a terminal or computer for local console access. The RSP
also provides an auxiliary port to connect to a modem for remote dial-in console access.
Both ports have RJ45 connectors, support RS-232 asynchronous data, and have distance
recommendations specified in the IEEE RS-232 standard.
Interference Considerations
When wires are run for any significant distance, there is a risk that stray signals will be induced on the
wires as interference. If interference signals are strong, they can cause data errors or damage to the
equipment.
The following sections describe sources of interference and how to minimize its effects on the Cisco
ASR 903 Series Aggregation Services Router system.
Electromagnetic Interference
All equipment powered by AC current can propagate electrical energy that can cause EMI and possibly
affect the operation of other equipment. The typical sources of EMI are equipment power cords and
power service cables from electric utility companies.
Strong EMI can destroy the signal drivers and receivers in the Cisco ASR 903 Series Aggregation
Services Router and even create an electrical hazard by causing power surges through the power lines
into installed equipment. These problems are rare but could be catastrophic.
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
OL-25178-02
2-13
Chapter 2
Preparing for Installation
Site Planning
To resolve these problems, you need specialized knowledge and equipment that could consume
substantial time and money. However, you can ensure that you have a properly grounded and shielded
electrical environment, paying special attention to the need for electrical surge suppression.
For information about the electrode magnetic compliance standards supported on the Cisco ASR 903
Series Aggregation Services Router, see Regulatory Compliance and Safety Information for the Cisco
ASR 903 Series Aggregation Services Router.
Radio Frequency Interference
When electromagnetic fields act over a long distance, radio frequency interference (RFI) may be
propagated. Building wiring can often act as an antenna, receiving the RFI signals and creating more
EMI on the wiring.
If you use twisted-pair cable in your plant wiring with a good distribution of grounding conductors, the
plant wiring is unlikely to emit radio interference. If you exceed the recommended distances, use a
high-quality twisted-pair cable with one ground conductor for each data signal.
Lightning and AC Power Fault Interference
If signal wires exceed the recommended cabling distances, or if signal wires pass between buildings, you
should consider the effect that a lightning strike in your vicinity might have on the Cisco ASR 903 Series
Aggregation Services Router.
The electromagnetic pulse (EMP) generated by lightning or other high-energy phenomena can couple
enough energy into unshielded conductors to damage or destroy electronic equipment. If you have
previously experienced such problems, you should consult with RFI and EMI experts to ensure that you
have adequate electrical surge suppression and shielding of signal cables in your Cisco ASR 903 Series
Aggregation Services Router operating environment.
Rack-Mounting Guidelines
The following sections provide guidelines for rack-mounting the Cisco ASR 903 Series Aggregation
Services Router:
•
Precautions for Rack-Mounting, page 2-14
•
Rack Selection Guidelines, page 2-15
•
Equipment Rack Guidelines, page 2-15
Precautions for Rack-Mounting
The following rack-mount guidelines are provided to ensure your safety:
•
Do not move large racks by yourself. Due to the height and weight of a rack, a minimum of two
people are required to accomplish this task.
•
Ensure that the rack is level and stable before extending a component from the rack.
•
Ensure that proper airflow is provided to the components in the rack.
•
Do not step on or stand on any component or system when servicing other systems or components
in a rack.
•
When mounting the Cisco ASR 903 Series Aggregation Services Router in a partially filled rack,
load the rack from the bottom to the top, with the heaviest component at the bottom of the rack.
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
2-14
OL-25178-02
Chapter 2
Preparing for Installation
Site Planning
•
If the rack is provided with stabilizing devices, install the stabilizers before mounting or servicing
the unit in the rack.
Rack Selection Guidelines
The Cisco ASR 903 Series Aggregation Services Router can be mounted in most two-post or four-post,
19-inch equipment racks that comply with the Electronic Industries Association (EIA) standard for
equipment racks (EIA-310-D 19-inch). The rack must have at least two posts with mounting flanges to
mount the chassis.
Caution
When mounting a chassis in any type of rack equipment, ensure that the inlet air to the chassis does not
exceed 65 degrees C.
The distance between the center lines of the mounting holes on the two mounting posts must be 18.31
inches ± 0.06 inch (46.50 cm ± 0.15 cm). The rack-mounting hardware included with the chassis is
suitable for most 19-inch equipment racks.
Consider installing the Cisco ASR 903 Series Aggregation Services Router in a rack with the following
features:
Note
•
Network Equipment Building System (NEBS) compliant, 19-inch (48.3 cm) wide rack.
•
EIA or European Telecommunications Standards Institute (ETSI) hole patterns in the mounting
rails. The required mounting hardware is shipped with the Cisco ASR 903 Series Aggregation
Services Router. If the rack that you plan to install the system in has metric-threaded rails, you must
provide your own metric-mounting hardware.
•
Perforated top and open bottom for ventilation to prevent overheating.
•
Leveling feet for stability.
The Cisco ASR 903 Series Aggregation Services Router should not be installed in an enclosed rack
because the chassis requires an unobstructed flow of cooling air to maintain acceptable operating
temperatures for its internal components. Installing the router in any type of enclosed rack—even with
the side doors removed—could disrupt the air flow, trap heat next to the chassis, and cause an
overtemperature condition inside the router. If you use an enclosed rack, ensure that there are air vents
on all sides of the rack and there is proper ventilation.
Equipment Rack Guidelines
The placement of the rack can affect personnel safety, system maintenance, and the system’s ability to
operate within the environmental characteristics described in the “System Specifications” section on
page 1-2. Choose a proper location for the Cisco ASR 903 Series Aggregation Services Router by
following the following guidelines.
Locating for Safety
If the Cisco ASR 903 Series Aggregation Services Router is the heaviest or the only piece of equipment
in the rack, consider installing it at or near the bottom to ensure that the rack’s center of gravity is as low
as possible.
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
OL-25178-02
2-15
Chapter 2
Preparing for Installation
Site Planning
For additional information about the proper placement of electronic equipment, consult the document
GR-63-CORE, Network Equipment Building System (NEBS) Requirements: Physical Protection.
Locating for Easy Maintenance
Keep at least 3 feet of clear space at the front and back of the rack. This space ensures that you can
remove the Cisco ASR 903 Series Aggregation Services Router components and perform routine
maintenance and upgrades easily.
Avoid installing the Cisco ASR 903 Series Aggregation Services Router in a congested rack and consider
how routing of cables from other pieces of equipment in the same rack could affect access to the router
cards.
The front and top of the chassis must remain unobstructed to ensure adequate airflow and prevent
overheating inside the chassis.
Allow the following clearances for normal system maintenance:
•
At the top of the chassis—At least 3 inches (7.6 cm)
•
In the front of the chassis—3 to 4 ft (91.44 cm to 121.92 cm)
To avoid problems during installation and ongoing operations, follow these general precautions when
you plan equipment locations and connections:
•
Use the show environment all command regularly to check the internal system status. The
environmental monitor continually checks the interior chassis environment; it provides warnings
about high temperature and creates reports on other potentially dangerous occurrences. If warning
messages are displayed, take immediate action to identify the cause, and correct the problem.
•
Keep the Cisco ASR 903 Series Aggregation Services Router off the floor and out of areas that
collect dust.
•
Follow ESD-prevention procedures to avoid damage to equipment. Damage from static discharge
can cause immediate or intermittent equipment failure.
Locating for Proper Airflow
Ensure that the Cisco ASR 903 Series Aggregation Services Router location has enough airflow to keep
the system operating within the environmental characteristics and the air temperature is sufficient to
compensate for the heat dissipated by the system. For more information, see “Air Flow Guidelines”
section on page 2-10.
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
2-16
OL-25178-02
Chapter 2
Preparing for Installation
Site Planning
Installation Checklist
To assist you with your installation and to provide a record of what was done by whom and when,
photocopy the Cisco ASR 903 Series Aggregation Services Router Installation Checklist shown in
Table 2-1. Use this to record the completion and verification of each procedure. After the checklist is
completed, place it in your Site Log along with the other records pertaining to your new Cisco router.
Table 2-1
Cisco ASR 903 Series Aggregation Services Router Installation Checklist
Verified
By
Task
Date
Date on which chassis received
Chassis and all accessories unpacked
Types and numbers of interfaces verified
Safety recommendations and guidelines reviewed
Installation Checklist copied
Site Log established and background information entered
Site power voltages verified
Site environmental specifications verified
Required passwords, IP addresses, device names, and so on, available
Required tools available
Network connection equipment available
Cable-management brackets installed (optional, but recommended)
AC power cables connected to AC sources and router
DC power cables connected to DC sources and router
Network interface cables and devices connected
System power turned on
System boot complete (STATUS LED is on)
Shared port adapters are operational
Correct software configuration displayed after system banner appears
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
OL-25178-02
2-17
Chapter 2
Preparing for Installation
Receiving the Cisco ASR 903 Series Aggregation Services Router
Creating a Site Log
The Site Log provides a record of all the actions related to installing and maintaining the router. Keep it
in an accessible place near the chassis so that anyone who performs tasks has access to it.
Create the Site Log prior to the installation. (See Appendix A, “Site Log” for more information on the
Site Log as well as a sample Site Log that can be used to make copies.)
Receiving the Cisco ASR 903 Series Aggregation Services
Router
Each Cisco ASR 903 Series Aggregation Services Router chassis is shipped in a container that is
strapped to a pallet, as illustrated in Figure 2-1.
Figure 2-1
Cisco ASR 903 Series Aggregation Services Router Packaged for Shipping
1
132823
2
3
Note
1
Outside carton
3
2
Pallet
— —
Packing straps
We recommend that you have at least two people available to help with the installation and ensure safe
lifting.
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
2-18
OL-25178-02
Chapter 2
Preparing for Installation
Receiving the Cisco ASR 903 Series Aggregation Services Router
Chassis-Lifting Guidelines
The chassis is not intended to be moved frequently. Before you install the system, ensure that your site
is properly prepared so that you can avoid having to move the chassis later to accommodate power
sources and network connections.
Two or more people are required to lift the chassis. Each time you lift the chassis or any heavy object,
follow these guidelines:
Warning
•
Never attempt to lift the chassis by yourself. Because of the size and weight of the chassis, use at
least two people to safely lift and move it without causing injury to yourself or damaging the
equipment.
•
Ensure that your footing is solid, and balance the weight of the chassis between your feet.
•
Lift the chassis slowly; never move suddenly or twist your body as you lift.
•
Keep your back straight and lift with your legs, not your back. If you must bend down to lift the
chassis, bend at the knees, not at the waist, to reduce the strain on your back muscles.
•
Do not remove installed components from the chassis.
•
Always disconnect all external cables before lifting or moving the chassis.
To prevent personal injury or damage to the chassis, never attempt to lift or tilt the chassis using the
handles on modules (such as power supplies, fans, or cards); these types of handles are not designed
to support the weight of the unit. Lift the unit only by using handles that are an integral part of the
chassis, or by grasping the chassis underneath its lower edge. Statement 163
Perform the following to lift a chassis:
Step 1
Each person should stand on either side of the chassis and place one hand under the air intake at the
bottom front of the chassis.
Step 2
With the other hand, grasp the top rear of the chassis under the air exhaust, and carefully lift the chassis.
Tools and Equipment
You need the following tools and equipment to install and upgrade the router and its components:
•
ESD-preventive cord and wrist strap
•
Antistatic mat or antistatic foam
•
Number 1 and Number 2 Phillips-head screwdrivers
•
Flat-blade screwdrivers: Small 3/16-inch (0.476 cm) and medium 1/4-inch (0.625 cm):
– To install or remove modules
– To remove the cover if you are upgrading the memory or other components
•
#12-24 pan-head screws to secure the router to the equipment rack
•
Cables for connecting to the WAN and LAN ports (depending on the configuration)
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
OL-25178-02
2-19
Chapter 2
Preparing for Installation
Receiving the Cisco ASR 903 Series Aggregation Services Router
Note
Warning
For more information on cable specifications, see Chapter 5, “Troubleshooting.”
•
Ethernet hub or switch or PC with a network interface card for connecting to the Ethernet ports
•
Console terminal (an ASCII terminal or a PC running terminal emulation software) that is
configured for 9600 baud, 8 data bits, no parity, and 2 stop bits
•
Console cable for connecting to the console port
•
(Optional) Modem for connecting to the auxiliary port for remote administrative access
•
Auxiliary cable for connecting to the auxiliary port (you can supply this cable or order one)
•
Ratcheting torque screwdriver with a Phillips head that exerts up to 30 pound-force per square inch
(lbf/sq in) of pressure
•
Crimping tool as specified by the ground lug manufacturer
•
18 AWG copper wire for the power cord
•
Wire-stripping tools for stripping both 6 AWG and 18 AWG wire
•
Tape measure and level
Only trained and qualified personnel should be allowed to install or replace this equipment.
Statement 49
Unpacking and Verifying the Shipped Contents
When you receive your chassis, perform the following steps and use the Shipping Contents Checklist:
Table 2-2
Step 1
Inspect the box for any shipping damage. If there is obvious physical damage, contact your Cisco service
representative.
Step 2
Unpack the Cisco ASR 903 Series Aggregation Services Router.
Step 3
Perform a visual inspection of the chassis.
Step 4
Use Table 2-2 to check the contents of the Cisco ASR 903 Series Aggregation Services Router shipping
container. Do not discard the shipping container. You will need the container if you move or ship the
Cisco ASR 903 Series Aggregation Services Router in the future.
Cisco ASR 903 Series Aggregation Services Router Shipping Container Contents
Component
Description
Chassis
Cisco ASR 903 Series Aggregation Services Router chassis
Fan tray
Power supplies
RSP
Interface modules
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
2-20
OL-25178-02
Chapter 2
Preparing for Installation
Receiving the Cisco ASR 903 Series Aggregation Services Router
Table 2-2
Cisco ASR 903 Series Aggregation Services Router Shipping Container Contents (continued)
Component
Description
Accessories kit
Chassis rack-mount brackets (19-inch EIA)
Three sets of screws:
•
Front and rear rack-mount bracket screws (2 sets)
•
Cable-management bracket screws
Six cable-management brackets (one per bracket)
One earth lug with two 10-32 screws.
1 RJ45 to RJ45 crossover cable
1 RJ45 to DB-9 (female) adapter
ESD, wrist strap (disposable)
One disposable wrist strap (optional)
Documentation
Regulatory Compliance and Safety Information for the Cisco ASR 903 Series
Aggregation Services Router
Optional equipment
Check the container for the following optional equipment:
Note
•
Power cord if an AC power supply was shipped. There are no cords for the DC
power supply units.
•
T1/E1 cable connector (required only for T1/E1 interface modules)
Most Cisco documentation is available online. Documentation that is shipped with your Cisco ASR 903
Series Aggregation Services Router includes the Regulatory Compliance and Safety Information for the
Cisco ASR 903 Series Aggregation Services Router document, and the Cisco ASR 903 Series Aggregation
Services Router Documentation Roadmap that contains information about the various documents that are
available online and the links to them.
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
OL-25178-02
2-21
Chapter 2
Preparing for Installation
Receiving the Cisco ASR 903 Series Aggregation Services Router
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
2-22
OL-25178-02
CH A P T E R
3
Installing the Cisco ASR 903 Series Aggregation
Services Router
This chapter describes how to install the Cisco ASR 903 Series Aggregation Services Router and
includes the following sections:
•
Prerequisites, page 3-1
•
Installing the Router in a Rack, page 3-1
•
Installing the Chassis Ground Connection, page 3-5
•
Installing the Fan Tray, page 3-8
•
RSP Installation, page 3-10
•
Interface Module Installation, page 3-14
•
Installing the Power Supply, page 3-16
•
Connecting the Cisco ASR 903 Series Aggregation Services Router to the Network, page 3-23
Prerequisites
Before installing the Cisco ASR 903 Series Aggregation Services Router, it is important to prepare for
the installation by:
•
Preparing the site (site planning) and reviewing the installation plans or method of procedures
(MOP)
•
Unpacking and inspecting the Cisco ASR 903 Series Aggregation Services Router
•
Gathering the tools and test equipment required to properly install the Cisco ASR 903 Series
Aggregation Services Router
For more instructions on how to prepare for the installation of the Cisco ASR 903 Series Aggregation
Services Router, see Chapter 2, “Preparing for Installation.”
Installing the Router in a Rack
The following sections describe how to install the Cisco ASR 903 Series Aggregation Services Router
in a rack:
•
Installing the Chassis Brackets, page 3-2
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
OL-25178-02
3-1
Chapter 3
Installing the Cisco ASR 903 Series Aggregation Services Router
Installing the Router in a Rack
•
Installing the Router Chassis in the Rack, page 3-3
•
Attaching the Cable Management Brackets, page 3-4
Installing the Chassis Brackets
The chassis is shipped with mounting brackets that can be installed on the front or rear of the chassis.
To install the brackets on the front of the chassis, perform these steps:
Step 1
Remove the rack-mount brackets from the accessory kit and position them beside the router chassis.
Figure 3-1 shows how to attach the brackets on the Cisco ASR 903 Series Aggregation Services Router
for a 19-inch EIA rack.
Attaching Mounting Brackets for a 19-inch EIA Rack
209338
Figure 3-1
Figure 3-2 shows how to attach the brackets on the Cisco ASR 903 Series Aggregation Services Router
for a 300 mm ETSI cabinet.
Attaching Mounting Brackets for a 300 mm ETSI Cabinet
209247
Figure 3-2
Step 2
Position one of the brackets against the chassis side, and align the screw holes.
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
3-2
OL-25178-02
Chapter 3
Installing the Cisco ASR 903 Series Aggregation Services Router
Installing the Router in a Rack
Step 3
Secure the bracket to the chassis with the screws removed when performing Step 1. The recommended
maximum torque is 28 lbf/sq in.
Step 4
Repeat Step 2 and Step 3 for the other bracket.
Installing the Router Chassis in the Rack
To install the router chassis in the equipment rack, perform these steps:
Step 1
Step 2
Caution
Position the chassis in the rack as follows:
•
If the front of the chassis (front panel) is at the front of the rack, insert the rear of the chassis between
the mounting posts.
•
If the rear of the chassis is at the front of the rack, insert the front of the chassis between the
mounting posts.
Align the mounting holes in the bracket (and optional cable guide) with the mounting holes in the
equipment rack.
Do not use interface module and power supply ejector handles to lift the chassis; using the handles to
lift the chassis can deform or damage the handles.
Installing the Chassis in a 19-inch EIA Rack
209248
Figure 3-3
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
OL-25178-02
3-3
Chapter 3
Installing the Cisco ASR 903 Series Aggregation Services Router
Installing the Router in a Rack
Installing the Chassis to support the Japanese JIS Rack Standard
Figure 3-5
Installing the Chassis in a 300 mm ETSI Cabinet
209246
343345
Figure 3-4
Step 3
Install the 8 or 12 (4 or 6 per side) 12-24 x 3/4-inch or 10-32 x 3/4-inch screws through the holes in the
bracket and into the threaded holes in the equipment rack posts.
Step 4
Use a tape measure and level to verify that the chassis is installed straight and level.
Attaching the Cable Management Brackets
To install the optional cable management brackets, perform these steps:
Step 1
Position the cable management brackets against the front of the chassis and align the four screw holes,
as shown in Figure 3-6.
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
3-4
OL-25178-02
Chapter 3
Installing the Cisco ASR 903 Series Aggregation Services Router
Installing the Chassis Ground Connection
Cable Management Bracket Installation
282406
Figure 3-6
Step 2
Secure the cable management brackets with four M4 screws. The recommended maximum torque is 10
lbf/sq in.
Installing the Chassis Ground Connection
Before you connect the power or turn on the power to the Cisco ASR 903 Series Aggregation Services
Router, you must provide an adequate chassis ground (earth) connection to your router.
This section describes how to ground the Cisco ASR 903 Series Aggregation Services Router chassis.
The router provides two locations for attaching a 2-hole grounding lug according to the rack-mounting
brackets you use to install the router. The Cisco ASR 903 Series Aggregation Services Router supports
the following rack-mounting types:
•
EIA 19-inch rack—Attach the grounding lug to the rear of the router, as shown in Figure 3-7.
Figure 3-7
Attaching a Grounding Lug to the Rear of the Router
281928
1
1
•
Grounding lug (19-inch EIA rack)
300 mm ETSI cabinet—Attach the grounding lug on the rack-mount bracket on the front of the
router, as shown in Figure 3-8.
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
OL-25178-02
3-5
Chapter 3
Installing the Cisco ASR 903 Series Aggregation Services Router
Installing the Chassis Ground Connection
Figure 3-8
Attaching a Grounding Lug to the Rack-Mount Bracket
1
GE-0
GE-1
GE-2
GE-3
GE-4
GE-5
GE-6
GE-7
GE-0
GE-1
GE-2
GE-3
GE-4
GE-5
GE-6
GE-7
PWR
FAN TEMP
STAT
CRIT MAJ MIN
PWR
STAT
GE-0
GE-1
GE-2
GE-3
GE-4
GE-5
GE-6
GE-7
PWR
RUDY RSP
STAT
SYNC
ACT
PWR
MEM
CONSOLE
1PPS
IN
1PPS
OUT
1OMHZ
IN
1OMHZ
OUT
PWR
TOD
BITS
STAT
L
0
S
L
1
S
L
2
S
L
3
S
L
4
S
L
5
S
L
6
S
L
MGMT
ENET
STAT
24V—60V
28A
7 S
PWR
STAT
L
0
S
L
1
S
L
2
S
L
3
S
L
4
S
L
5
S
L
6
S
L
7 S
L
0
S
L
1
S
L
2
S
L
3
S
L
4
S
L
5
S
L
6
S
L
7 S
PWR
INPUT
OK
OUTPUT
FAIL
24V—60V
28A
INPUT
OK
OUTPUT
FAIL
ALARM
281929
STAT
1
Grounding lug (300 mm ETSI cabinet)
To ensure that the chassis ground connection that you provide is adequate, you need the following parts
and tools:
•
Ratcheting torque screwdriver with Phillips head that exerts up to 15 lbf/sq in of pressure for
attaching the ground wire to the router
•
Crimping tool as specified by the ground lug manufacturer
•
18 AWG copper wire for the power cord
•
6 AWG or larger copper wire for the ground wire
•
Wire-stripping tools appropriate to the wire you are using
Caution
Before making connections to the Cisco ASR 903 Series Aggregation Services Router, ensure
that you disconnect the power at the circuit breaker. Otherwise, severe injury to you or damage
to the router may occur.
Warning
This equipment must be grounded. Never defeat the ground conductor or operate the equipment in the
absence of a suitably installed ground conductor. Contact the appropriate electrical inspection
authority or an electrician if you are uncertain that suitable grounding is available. Statement 1024
Warning
Use copper conductors only. Statement 1025
Warning
When installing the unit, the ground connection must always be made first and disconnected last.
Statement 42
This unit is to be installed in a restrictive access location and must be permanently grounded to minimum
6 AWG copper ground wire.
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
3-6
OL-25178-02
Chapter 3
Installing the Cisco ASR 903 Series Aggregation Services Router
Installing the Chassis Ground Connection
Perform the following procedure to ground the Cisco ASR 903 Series Aggregation Services Router using
a 2-hole lug and the corresponding mounting point. Most carriers require a minimum 6 AWG ground
connection. Verify your carrier’s requirements for the ground connection.
Step 1
If your ground wire is insulated, use a wire-stripping tool to strip the ground wire to 0.5 inch ± 0.02 inch
(12.7 mm ±0.5 mm) (Figure 3-9).
Figure 3-9
Stripping a Ground Wire
Insulation
Wire lead
60528
0.5 in. (12.7 mm) ± 0.02 in. (0.5 mm)
Step 2
Slide the open end of your 2-hole ground lug over the exposed area of the ground wire.
Step 3
Using a crimping tool (as specified by the ground lug manufacturer), crimp the ground lug to the ground wire
as shown in Figure 3-10.
Crimping a Ground Lug onto the Ground Wire
60529
Figure 3-10
Step 4
Use a Phillips head screwdriver to attach the 2-hole ground lug and wire assembly to the router with the
2 pan-head Phillips head screws. For a 19-inch EIA rack, attach the 2-hole ground lug to the rear of the
router.
Step 5
Connect the other end of the ground wire to a suitable grounding point at your site.
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
OL-25178-02
3-7
Chapter 3
Installing the Cisco ASR 903 Series Aggregation Services Router
Installing the Fan Tray
Installing the Fan Tray
The fan tray is a modular unit that provides cooling to the Cisco ASR 903 Series Aggregation Services
Router. Follow these steps to install the fan tray in the chassis:
Step 1
Orient the fan tray so that the captive screws are on the left side of the fan tray’s front panel. Figure 3-11
shows how to orient the fan tray.
Figure 3-11
GE-0
GE-1
Installing the Fan Tray
GE-2
GE-3
GE-4
GE-5
GE-6
GE-7
PWR
STAT
GE-0
GE-1
GE-2
GE-3
GE-4
GE-5
GE-6
GE-7
GE-0
GE-1
GE-2
GE-3
GE-4
GE-5
GE-6
GE-7
PWR
STAT
FAN TEMP
PWR
RUDY RSP
STAT
SYNC
CRIT MAJ MIN
ACT
PWR
MEM
CONSOLE
1PPS
IN
1PPS
OUT
1OMHZ
IN
1OMHZ
OUT
STAT
L
0
S
L
1
S
L
2
S
L
3
S
L
4
S
L
5
S
L
6
S
L
7 S
L
0
S
L
1
S
L
2
S
L
3
S
L
4
S
L
5
S
L
6
S
L
7 S
L
0
S
L
1
S
L
2
S
L
3
S
L
4
S
L
5
S
L
6
S
L
7 S
PWR
TOD
BITS
MGMT
ENET
STAT
24V—60V
28A
PWR
PWR
STAT
INPUT
OK
OUTPUT
FAIL
24V—60V
28A
INPUT
OK
OUTPUT
FAIL
ALARM
Step 2
Guide the fan tray into the chassis until it is fully seated.
Caution
Step 3
281934
STAT
The fans are exposed on the left side of the fan tray. Keep your fingers, clothing, and jewelry
away from the fans. Always handle the fan tray by the handle.
Secure the fan tray to the chassis using the attached captive installation screws. The recommended
maximum torque is 5.5 lbf/sq in.
This completes the procedure for installing or replacing the fan tray in a Cisco ASR 903 Series
Aggregation Services Router.
For information about connecting cables to the fan tray alarm port, see “Connecting the Fan Tray Alarm
Port” section on page 3-37. For a summary of the LEDs on the fan tray, see “LED Summary” section on
page 5-7.
Removing and Replacing the Fan Tray
The fan tray supports online insertion and removal (OIR). There is no need to power down the Cisco
ASR 903 Series Aggregation Services Router to remove or replace the fan tray. However, the router will
shut down if the fan tray is removed from the chassis for more than two minutes.
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
3-8
OL-25178-02
Chapter 3
Installing the Cisco ASR 903 Series Aggregation Services Router
Installing the Fan Tray
Follow these steps to remove and replace the fan tray on the Cisco ASR 903 Series Aggregation Services
Router:
Step 1
Using a No. 2 Phillips screwdriver or your fingers, loosen the captive installation screw that secures the
fan tray to the chassis. Figure 3-12 shows the front of the fan tray, including the captive installation
screws.
Figure 3-12
Captive
installation
screw
Detaching the Fan Tray
FAN TEMP
CRIT MAJ MIN
Handle
209393
ALARM
Step 2
Grasp the fan tray handle with one hand and the outside of the chassis with the other hand. Figure 3-12
shows the front of the fan tray, including the handle.
Caution
The fans are exposed on the left side of the fan tray. Keep your fingers, clothing, and jewelry
away from the fans. Always handle the fan tray by the handle.
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
OL-25178-02
3-9
Chapter 3
Installing the Cisco ASR 903 Series Aggregation Services Router
RSP Installation
Step 3
Pull the fan tray backward toward you no more than 1 inch to disengage it from the power receptacle on
the midplane, as shown in Figure 3-13.
Figure 3-13
Fan Tray Removal
FAN TEMP
SYNC
CRIT MAJ MIN
ACT
PWR
TOD
BITS
MGMT
ENET
STAT
24V—60V
28A
209394
ALARM
When removing the fan tray, keep your hands and fingers away from the spinning fan
blades. Let the fan blades completely stop before you remove the fan tray. Statement 258
Warning
Step 4
Wait at least 5 seconds to allow the fans to stop spinning. Then, pull the fan tray backward toward you
and out of the chassis.
Note
As the fan tray slides out of the chassis, support the bottom of the fan tray with one hand and
keep your other hand on the fan tray handle.
This completes the steps for removing the fan tray from the chassis.
To install the new fan tray, follow the steps in “Installing the Fan Tray” section on page 3-8.
RSP Installation
Follow these steps on handling an RSP module in the Cisco ASR 903 Series Aggregation Services
Router:
•
Installing an RSP Module, page 3-11
•
Removing an RSP Module, page 3-12
•
Hot-Swapping an RSP Module, page 3-13
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
3-10
OL-25178-02
Chapter 3
Installing the Cisco ASR 903 Series Aggregation Services Router
RSP Installation
Installing an RSP Module
To install an RSP module in the router chassis, perform the following steps:
Step 1
Choose a slot for the module. Make sure that there is enough clearance to accommodate any equipment
that will be connected to the ports on the module. If a blank module filler plate is installed in the slot in
which you plan to install the module, remove the plate by removing its 2 Phillips pan-head screws.
Step 2
Fully open both the ejector levers on the new module, as shown in Figure 3-14.
Caution
Step 3
To prevent ESD damage, handle modules by carrier edges only.
Position the module in the slot. Make sure that you align the sides of the module with the guides on each
side of the slot, as shown in Figure 3-14.
Figure 3-14
Cisco ASR 903 Series Aggregation Services Router RSP Installation
GE-0
GE-0
GE-0
GE-0
GE-0
RUDY RSP
GE-0
GE-1
GE-1
GE-1
GE-1
GE-1
GE-1
GE-2
GE-2
GE-2
GE-2
GE-2
GE-2
GE-3
GE-4
GE-5
GE-6
GE-7
PWR
GE-3
GE-4
GE-5
STAT
GE-6
GE-7
PWR
GE-3
GE-4
GE-5
STAT
GE-6
GE-7
FAN TEM
P
PWR
GE-3
GE-4
GE-5
STAT
GE-6
CRIT MAJ
MIN
GE-7
PWR
GE-3
GE-4
GE-5
STAT
GE-6
GE-7
PWR
GE-3
GE-4
GE-5
STAT
GE-6
GE-7
PWR
CONSOLE
1PPS
IN
INPUT
OK
OUTPUT
FAIL
STAT
1PPS
OUT
1OMHZ
IN
1OMHZ
OUT
SYNC
ACT
TOD
BITS
Step 4
MGMT
ENET
PWR
STAT
24V—60V
28A
INPUT
OK
OUTPUT
FAIL
24V—60V
28A
ALARM
281932
MEM
Carefully slide the module into the slot until the EMI gasket on the module makes contact with the
module in the adjacent slot and both the ejector levers have closed to approximately 45 degrees with
respect to the module faceplate.
Caution
If the top slot already has an RSP module installed, and you install a second RSP module in
the slot below it, be careful not to damage the EMI gasket of the bottom RSP module against
the ejector levers of the top RSP during insertion.
Step 5
While pressing down, simultaneously close both the ejector levers to fully seat the module in the
backplane connector. The ejector levers are fully closed when they are flush with the module faceplate.
Step 6
Tighten the two captive installation screws on the module. The recommended maximum torque is 5.5
lbf/sq in.
Note
Make sure that the ejector levers are fully closed before tightening the captive installation
screws.
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
OL-25178-02
3-11
Chapter 3
Installing the Cisco ASR 903 Series Aggregation Services Router
RSP Installation
Step 7
Verify that the captive installation screws are tightened on all of the modules installed in the chassis.
This step ensures that the EMI gaskets on all the modules are fully compressed in order to maximize the
opening space for the new or replacement module.
Note
Note
If the captive installation screws are loose, the EMI gaskets on the installed modules will push
adjacent modules toward the open slot, which reduces the size of the opening and makes it
difficult to install the new module.
Blank module filler plates (Cisco part number A900-RSPA-BLANK) should be installed in any empty
chassis slots to keep dust out of the chassis and to maintain consistent airflow through the chassis.
Removing an RSP Module
Before you remove an RSP from the router, you should save the current configuration using the write
{host file | network | terminal} command. This saves you time when bringing the module back online.
If the module is running Cisco IOS software, save the current running configuration by entering the copy
running-config startup-config command.
Warning
Hazardous voltage or energy is present on the backplane when the system is operating. Use caution
when servicing. Statement 1034
Warning
Invisible laser radiation may be emitted from disconnected fibers or connectors. Do not stare into
beams or view directly with optical instruments. Statement 1051
To remove an RSP module, perform the following steps:
Step 1
Disconnect any cables attached to the ports on the module.
Step 2
Verify that the captive installation screws on all the modules in the chassis are tight. This step ensures
that the space created by the removed module is maintained.
Note
If the captive installation screws are loose, the EMI gaskets on the installed modules will push
the modules toward the open slot, which in turn reduces the size of the opening and makes it
difficult to remove the module.
Step 3
Loosen the two captive installation screws on the module you plan to remove from the chassis.
Step 4
Place your thumbs on the ejector levers (see Figure 3-14) and simultaneously rotate the ejector levers
outward to unseat the module from the backplane connector.
Step 5
Grasp the front edge of the module and slide the module straight out of the slot. If the chassis has
horizontal slots, place your hand under the module to support its weight as you slide it out from the slot.
Do not touch the module circuitry.
Caution
To prevent ESD damage, handle modules by the carrier edges only.
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
3-12
OL-25178-02
Chapter 3
Installing the Cisco ASR 903 Series Aggregation Services Router
RSP Installation
Step 6
Place the module on an antistatic mat or antistatic foam, or immediately reinstall the module in another
slot.
Step 7
Install blank module filler plates (Cisco part number A900-RSPA-BLANK) in empty slots, if any.
Warning
Blank faceplates and cover panels serve three important functions: they prevent exposure to
hazardous voltages and currents inside the chassis; they contain electromagnetic interference (EMI)
that might disrupt other equipment; and they direct the flow of cooling air through the chassis. Do not
operate the system unless all cards, faceplates, front covers, and rear covers are in place. Statement
1029
Hot-Swapping an RSP Module
The Cisco ASR 903 Series Aggregation Services Router provides a feature that allows you to remove
and replace a redundant RSP module without powering down the router. This feature, called
hot-swapping or OIR, allows you to remove and replace a redundant module without disrupting router
operation.
When two redundant modules are installed in the router, only one of the modules is active. The other one
runs in standby mode, ready to take over processing if the active module fails.
When you remove or insert a redundant module while the router is powered on and running, the router
does the following:
1.
Determines if there is sufficient power for the module.
2.
Scans the backplane for configuration changes.
3.
Initializes the newly inserted module. In addition, the system notes any removed modules and places
those modules in the administratively shutdown state.
4.
Places any previously configured interfaces on the module back to the state they were in when they
were removed. Any newly inserted interfaces are put in the administratively shutdown state as if they
were present (but unconfigured) at boot time. If you insert the same type of module into a slot, its
ports are configured and brought online up to the port count of the original module.
The router runs diagnostic tests on any new interfaces and the test results indicate the following:
•
If the tests pass, the router is operating normally.
•
If the new module is faulty, the router resumes normal operation but leaves the new interfaces
disabled.
•
If the diagnostic tests fail, the router stops operating, which usually indicates that the new module
has a problem in the bus and should be removed.
Use the following guidelines when performing an OIR on an IM:
•
Allow at least 2 minutes for the system to reinitialize before inserting a new IM.
•
Avoid inserting a new IM during bootup until the active and standby RSPs have reached an OK state.
•
When inserting multiple IMs into the chassis, wait until each IM reaches an OK state before
inserting the next IM.
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
OL-25178-02
3-13
Chapter 3
Installing the Cisco ASR 903 Series Aggregation Services Router
Interface Module Installation
Interface Module Installation
The following sections describe the various tasks of associated with interface module installation on the
Cisco ASR 903 Series Aggregation Services Router:
•
Installing an Interface Module, page 3-14
•
Removing an Interface Module, page 3-15
•
Hot-Swapping an Interface Module, page 3-15
Installing an Interface Module
Step 1
Before inserting an interface module, make sure that the chassis is grounded.
Step 2
To insert the interface module, carefully align the edges of the interface module between the upper and
lower edges of the router slot.
Step 3
Carefully slide the interface module into the router slot until the interface module makes contact with
the backplane. Figure 3-15 shows how to install the interface module.
Inserting an Interface Module
282442
Figure 3-15
Step 4
Tighten the locking thumbscrews on both sides of the interface module. The recommended maximum
torque is 5.5 lbf/sq in.
Step 5
Connect all the cables to each interface module.
Note
Caution
10 Gigabit Ethernet interface modules are not supported in slots 4 and 5.
Do not use interface module and power supply ejector handles to lift the chassis; using the handles to
lift the chassis can deform or damage the handles.
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
3-14
OL-25178-02
Chapter 3
Installing the Cisco ASR 903 Series Aggregation Services Router
Interface Module Installation
Removing an Interface Module
Step 1
To remove an interface module, disconnect all the cables from each interface module.
Step 2
Loosen the locking thumbscrews on both sides of the interface module.
Step 3
Slide the interface module out of the router slot by pulling on the handles. If you are removing a blank
filler plate, pull the blank filler plate completely out of the router slot using the captive screws.
Hot-Swapping an Interface Module
The Cisco ASR 903 Series Aggregation Services Router provides a feature that allows you to remove
and replace an interface module without powering down the router. This feature, called hot-swapping or
OIR, allows you to remove and replace a redundant module without disrupting router operation.
Note
The Cisco ASR 903 Series Aggregation Services Router does not support hot-swapping an interface
module with another module of a different type. For example, you cannot swap an SFP Gigabit Ethernet
module with a copper Gigabit Ethernet module without disrupting router operation.
Note
If you perform OIR on an interface module and move the module to a different slot, the router does not
retain the module configuration; you must reconfigure the interface module.
When you remove or insert a redundant module while the router is powered on and running, the router
does the following:
1.
Determines if there is sufficient power for the module.
2.
Scans the backplane for configuration changes.
3.
Initializes the newly inserted module. In addition, the system notes any removed modules and places
those modules in the administratively shutdown state.
4.
Places any previously configured interfaces on the module back to the state they were in when they
were removed.
The router runs diagnostic tests on any new interfaces and the test results indicate the following:
•
If the tests pass, the router is operating normally.
•
If the new module is faulty, the router resumes normal operation but leaves the new interfaces
disabled.
•
If the diagnostic tests fail, the router stops operating, which usually indicates that the new module
has a problem in the bus and should be removed.
Caution
To avoid erroneous failure messages, note the current configuration of all interfaces before
you remove or replace another module, and allow at least 15 seconds for the system to
reinitialize after a module has been removed or replaced.
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
OL-25178-02
3-15
Chapter 3
Installing the Cisco ASR 903 Series Aggregation Services Router
Installing the Power Supply
Installing the Power Supply
The Cisco ASR 903 Series Aggregation Services Router supports a 19.2 VDC to -72 VDC power supply.
The DC power supply uses 3-position terminal block to connect to the power source; it is labeled with
connections for +24/48 V, GRD (ground), and -24/48 V. You can install dual DC power supplies for
redundancy.
Warning
Caution
Read the installation instructions before connecting the system to the power source. Statement 10
Do not use interface module and power supply ejector handles to lift the chassis; using the handles to
lift the chassis can deform or damage the handles.
The following sections describe the Cisco ASR 903 Series Aggregation Services Router power supplies:
•
Preventing Power Loss, page 3-16
•
Power Connection Guidelines, page 3-16
•
Installing the DC Power Supply, page 3-17
•
Removing and Replacing the DC Power Supply, page 3-22
Preventing Power Loss
Use the following guidelines to prevent power loss to the router.
•
To prevent loss of input power, ensure that the total maximum load on each circuit supplying the
power supplies is within the current ratings of the wiring and breakers.
•
In some systems, you can use an UPS to protect against power failures at your site. Avoid UPS types
that use ferroresonant technology. These UPS types can become unstable with systems like the Cisco
ASR 903 Series Aggregation Services Router, which can have substantial current draw fluctuations
due to bursty data traffic patterns.
Use the information in the “DC Power Specifications” section on page 1-4 to estimate the power
requirements and heat dissipation of a Cisco ASR 903 Series Aggregation Services Router based on a
given configuration of the router. Determining power requirements is useful for planning the power
distribution system needed to support the router.
Power Connection Guidelines
This section provides guidelines for connecting the Cisco ASR 903 Series Aggregation Services Router
power supplies to the site power source.
Warning
Never defeat the ground conductor or operate the equipment in the absence of a suitably installed
ground conductor. Contact the appropriate electrical inspection authority or an electrician if you are
uncertain that suitable grounding is available. Statement 213
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
3-16
OL-25178-02
Chapter 3
Installing the Cisco ASR 903 Series Aggregation Services Router
Installing the Power Supply
Warning
The plug-socket combination must be accessible at all times because it serves as the main
disconnecting device. Statement 1019
Warning
This product requires short-circuit (overcurrent) protection, to be provided as part of the building
installation. Install only in accordance with national and local wiring regulations. Statement 1045
Guidelines for DC-Powered Systems
Basic guidelines for DC-powered systems include the following:
•
Each chassis power supply should have its own dedicated input power source. The source must
comply with the safety extra-low voltage (SELV) requirements in the UL 60950, CSA 60950, EN
60950, and IEC 60950 standards.
•
The circuit must be protected by a dedicated two-pole circuit breaker. The circuit breaker should be
sized according to the power supply input rating and local or national code requirements.
•
The circuit breaker is considered the disconnect device and should be easily accessible.
•
The system ground is the power supply and chassis ground.
•
Do not connect the DC return wire to the system frame or to the system grounding equipment.
•
Use the grounding lug to attach a wrist strap for ESD protection during servicing.
Installing the DC Power Supply
The following sections describe how to install a DC power supply in the Cisco ASR 903 Series
Aggregation Services Router:
•
Installing the Power Supply Module, page 3-17
•
Installing the Terminal Block, page 3-18
•
Activating the DC Power Supply, page 3-21
Installing the Power Supply Module
Perform the following procedure to install the power supply module:
Step 1
Ensure that the system (earth) ground connection has been made. For ground connection installation
instructions, see the “Installing the Chassis Ground Connection” section on page 3-5.
Step 2
Verify that power to the DC circuit connected to the power supply you are installing is off. To ensure that
power has been removed from the DC circuits, locate the circuit breakers for the DC circuits, switch the
circuit breakers to the OFF position, and tape the circuit-breaker switches in the OFF position.
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
OL-25178-02
3-17
Chapter 3
Installing the Cisco ASR 903 Series Aggregation Services Router
Installing the Power Supply
Step 3
Grasp the power supply handle with one hand. Place your other hand underneath the power supply, as
shown in Figure 3-16. Slide the power supply into the power supply bay. Make sure that the power
supply is fully seated in the bay.
Figure 3-16
GE-0
GE-1
Installing the DC Power Supply
GE-2
GE-3
GE-4
GE-5
GE-6
GE-7
PWR
STAT
GE-0
GE-1
GE-2
GE-3
GE-4
GE-5
GE-6
GE-7
GE-0
GE-1
GE-2
GE-3
GE-4
GE-5
GE-6
GE-7
PWR
STAT
FAN TEMP
PWR
RUDY RSP
STAT
SYNC
CRIT MAJ MIN
ACT
PWR
CONSOLE
MEM
1PPS
IN
1PPS
OUT
1OMHZ
IN
STAT
L
0
S
L
1
S
L
2
S
L
3
S
L
4
S
L
5
S
L
6
S
L
7 S
L
0
S
L
1
S
L
2
S
L
3
S
L
4
S
L
5
S
L
6
S
L
7 S
L
0
S
L
1
S
L
2
S
L
3
S
L
4
S
L
5
S
L
6
S
L
7 S
1OMHZ
OUT
PWR
TOD
BITS
MGMT
ENET
STAT
PWR
STAT
PWR
ALARM
INPUT
OK
OUTPUT
FAIL
Step 4
24V—60V
282340
STAT
28A
Tighten the captive installation screws of the power supply. The recommended maximum torque is 5.5
lbf/sq in.
If you are installing a redundant DC power supply, repeat these steps for the second power source.
Installing the Terminal Block
Perform the following procedure to install the terminal block:
Step 1
Locate the terminal block plug.
Step 2
Use a wire-stripping tool to strip the ends of each of the two wires coming from the DC-input power
source to 0.27 inch (6.6 mm) ± 0.02 inch (0.5 mm) and the wire for grounding. Do not strip more than
0.29 inch (7.4 mm) of insulation from the wire. Stripping more than the recommended amount of wire
can leave behind exposed wire from the terminal block plug after installation.
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
3-18
OL-25178-02
Chapter 3
Installing the Cisco ASR 903 Series Aggregation Services Router
Installing the Power Supply
Step 3
Identify the ground, positive, and negative feed positions for the terminal block connection. The
recommended wiring sequence is:
a.
Ground lead wire (right)
b.
Positive (+) lead wire (middle)
c.
Negative (-) lead wire (left)
Figure 3-17
DC Power Supply with Lead Wires
1
2
207765
3
Step 4
1
Ground lead wire
3
2
Positive (+) lead wire
— —
Negative (–) lead wire
Insert the exposed wire of one of the three DC-input power source wires into the terminal block plug.
Make sure that you cannot see any wire lead. Only wire with insulation should extend from the terminal
block.
Caution
Do not overtorque the plug captive screws of the terminal block. The recommended maximum
torque is from 0.5 Nm (4.425 lbf/sq in) to 0.6 Nm (5.310 lbf/sq in).
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
OL-25178-02
3-19
Chapter 3
Installing the Cisco ASR 903 Series Aggregation Services Router
Installing the Power Supply
Step 5
Use a ratcheting torque screwdriver to torque the terminal block plug captive screw (above the installed
wire lead) from 0.5 Nm (4.425 lbf/sq in) to 0.6 Nm (5.310 lbf/sq in) as shown in Figure 3-18.
Figure 3-18
Torquing the DC Power Supply Terminal Block Plug Screws
207764
1
1
Step 6
Torque is from 0.5 Nm (4.425 lbf/sq in) to 0.6 Nm (5.310 lbf/sq in)
Repeat Step 4 through Step 5 for the remaining DC input power source wire and the ground wire.
Figure 3-19 shows the wiring completed for a terminal block plug.
Figure 3-19
Inserting the DC Power Supply Terminal Block Plug in the Block Header
FAN TEM
P
RUDY RSP
CRIT MAJ
MIN
MEM
CONSOL
E
1PPS
IN
1PPS
OUT
1OMHZ
IN
1OMHZ
OUT
SYNC
ACT
TOD
BITS
MGMT
ENET
PWR
STAT
INPUT
OK
OUTPUT
FAIL
24V—60V
28A
INPUT
OK
24V—60V
1
2
28A
255730
OUTPUT
FAIL
ALARM
3
1
DC power supply ground lead wire
3
2
DC power supply negative (-) lead wire
— —
DC power supply positive (+) lead wire
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
3-20
OL-25178-02
Chapter 3
Installing the Cisco ASR 903 Series Aggregation Services Router
Installing the Power Supply
Caution
Secure the wires coming in from the terminal block plug so that they cannot be disturbed by
casual contact.
Step 7
Ensure that the terminal block plug is fully seated in the terminal block header on the DC power supply
panel. The plug has a locking feature. You should hear a snap or click when it is installed properly.
Step 8
Use a tie wrap to secure the wires to the rack, so that the wires are not pulled from the terminal block
plug by casual contact. Make sure the tie wrap allows for some slack in the ground wire, as shown in
Figure 3-20.
Figure 3-20
Complete DC Terminal Block Plug Insertion and Secure Tie Wrap
FAN TEM
P
RUDY RSP
CRIT MAJ
MIN
MEM
CONSOL
E
1PPS
IN
1PPS
OUT
1OMHZ
IN
1OMHZ
OUT
SYNC
ACT
TOD
BITS
MGMT
ENET
PWR
STAT
INPUT
OK
OUTPUT
FAIL
28A
INPUT
OK
OUTPUT
FAIL
24V—60V
28A
255731
24V—60V
ALARM
2
1
1
Step 9
Lead wires secured with a tie wrap
2
DC power supply terminal block plug being
inserted into terminal block header.
Use a tie wrap to secure the wires to the handle. Leave a service loop on the ground wire between the
handle and the connector such that it is the last to receive strain if the wires are pulled.
This completes the procedure for connecting the DC power supply in the Cisco ASR 903 Series
Aggregation Services Router.
If you are installing a redundant DC power supply, repeat these steps for the second power source.
Activating the DC Power Supply
Perform the following procedure to activate the DC power supply:
Step 1
Remove the tape from the circuit-breaker switch handle, and restore power by moving the circuit-breaker
switch handle to the On (|) position.
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
OL-25178-02
3-21
Chapter 3
Installing the Cisco ASR 903 Series Aggregation Services Router
Installing the Power Supply
Step 2
Verify power supply operation by checking if the power supply front panel LEDs are in the following
states:
•
INPUT OK LED is green
•
OUTPUT FAIL LED is not lit
If the LEDs indicate a power problem, see Chapter 5, “Troubleshooting.”
If you are installing a redundant DC power supply, ensure that each power supply is connected to a
separate power source in order to prevent power loss in the event of a power failure.
If you are installing a redundant DC power supply, repeat these steps for the second power source.
Removing and Replacing the DC Power Supply
This section provides information about removing and replacing the DC power supply in the Cisco ASR
903 Series Aggregation Services Router.
Note
The Cisco ASR 903 Series Aggregation Services Router power supplies are hot-swappable. If you have
installed redundant power supply modules, you can replace a single power supply without interrupting
power to the router.
Warning
When you install the unit, the ground connection must always be made first and disconnected last.
Statement 1046
Warning
Before performing any of the following procedures, ensure that power is removed from the DC circuit.
Statement 1003
Warning
Only trained and qualified personnel should be allowed to install, replace, or service this equipment.
Statement 1030
Warning
Installation of the equipment must comply with local and national electrical codes. Statement 1074
Follow these steps to remove and replace the DC power supply on the Cisco ASR 903 Series Aggregation
Services Router:
Step 1
Before servicing the power supply, switch off the circuit breaker in your equipment area. As an
additional precaution, tape the circuit-breaker switch in the Off position.
Step 2
Slip on the ESD-preventive wrist strap that was included in the accessory kit.
Step 3
Switch the power supply circuit-breaker switch to the Off (O) position.
Step 4
Pull the terminal block plug connector out of the terminal block head in the power supply.
Step 5
Loosen the captive screws on the DC power supply.
Step 6
Grasping the power supply handle with one hand, pull the power supply out from the chassis while
supporting it with the other hand.
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
3-22
OL-25178-02
Chapter 3
Installing the Cisco ASR 903 Series Aggregation Services Router
Connecting the Cisco ASR 903 Series Aggregation Services Router to the Network
Step 7
Loosen the four captive screws on the DC power supply.
Step 8
Grasping the power supply handles, pull the power supply from the chassis.
Step 9
Replace the DC power supply within 5 minutes.
Connecting the Cisco ASR 903 Series Aggregation Services
Router to the Network
The following sections describe how to connect cables on the Cisco ASR 903 Series Aggregation
Services Router:
•
Connecting Console Cables, page 3-23
•
Connecting to the Auxiliary Port, page 3-29
•
Connecting a Management Ethernet Cable, page 3-30
•
Installing and Removing SFP and XFP Modules, page 3-31
•
Connecting a USB Flash Device, page 3-31
•
Connecting Timing Cables, page 3-32
•
Connecting Ethernet Cables, page 3-34
•
Connecting Cables to SFP Modules, page 3-34
•
Connecting T1/E1 cables, page 3-34
•
Connecting the Fan Tray Alarm Port, page 3-37
•
Connector and Cable Specifications, page 3-37
Connecting Console Cables
The following sections describe how to connect to the Cisco ASR 903 Series Aggregation Services
Router using console cables:
Note
•
Connecting to the Serial Port using Microsoft Windows, page 3-24
•
Connecting to the Console Port using Mac OS X, page 3-26
•
Connecting to the Console Port using Linux, page 3-26
•
Installing the Cisco Microsoft Windows USB Device Driver, page 3-27
•
Uninstalling the Cisco Microsoft Windows USB Driver, page 3-28
You cannot use the USB and RS232 console ports at the same time; if you insert the USB cable into the
router, the RS232 port is disabled.
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
OL-25178-02
3-23
Chapter 3
Connecting the Cisco ASR 903 Series Aggregation Services Router to the Network
Installing the Cisco ASR 903 Series Aggregation Services Router
Connecting to the Serial Port using Microsoft Windows
This procedure shows how to connect to the serial port using Microsoft Windows.
Note
Install the USB device driver before establishing a physical connection between the router and the PC,
by using the USB Console cable plugged into the USB serial port. Otherwise, the connection will fail.
For more information, see the “Installing the Cisco Microsoft Windows USB Device Driver” section on
page 3-27.
Step 1
Connect the end of the console cable with the RJ45 connector to the light blue console port on the router.
or
Connect a USB Type A-to-Type A cable to the USB console port as shown in Figure 3-21. If you are
using the USB serial port for the first time on a Windows-based PC, install the USB driver now according
to the instructions in the following sections.
•
“Installing the Cisco Microsoft Windows XP USB Driver” section on page 3-27
•
“Installing the Cisco Microsoft Windows 2000 USB Driver” section on page 3-27
•
“Installing the Cisco Microsoft Windows Vista USB Driver” section on page 3-28
Note
You cannot use the USB port and the EIA port concurrently. See “Connecting to the Auxiliary
Port” section on page 3-29. When the USB port is used it takes priority over the RJ45 EIA port.
Note
The USB Type A-to-Type A cable is not included with the Cisco ASR 903 Series Aggregation
Services Router; it is ordered separately.
Step 2
Connect the end of the cable with the DB-9 connector (or USB Type-A) to the terminal or PC. If your
terminal or PC has a console port that does not accommodate a DB-9 connector, you must provide an
appropriate adapter for that port.
Step 3
To communicate with the router, start a terminal emulator application, such as Microsoft Windows
HyperTerminal. This software should be configured with the following parameters:
•
9600 baud
•
8 data bits
•
no parity
•
1 stop-bit
•
no flow control
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
3-24
OL-25178-02
Chapter 3
Installing the Cisco ASR 903 Series Aggregation Services Router
Connecting the Cisco ASR 903 Series Aggregation Services Router to the Network
Figure 3-21
Connecting the USB Console Cable to the Cisco ASR 903 Series Aggregation Services
Router
MEM
GE-0
GE-1
GE-2
GE-3
GE-4
GE-5
GE-6
1PPS
IN
CONSOLE
GE-7
PWR
RUDY RSP
FAN TEMP
SYNC
STAT
ACT
GE-0
GE-1
GE-2
GE-3
GE-4
GE-5
GE-6
PWR
PWR
MEM
CONSOLE
1PPS
IN
1PPS
OUT
1OMHZ
IN
1OMHZ
OUT
TOD
BITS
MGMT
ENET
MEM
CONSOLE
1PPS
IN
1PPS
OUT
1OMHZ
IN
1OMHZ
OUT
TOD
BITS
MGMT
ENET
STAT
24V—60V
28A
GE-7
CRIT MAJ MIN
STAT
STAT
GE-0
GE-1
GE-2
GE-3
GE-4
GE-5
GE-6
GE-7
PWR
RUDY RSP
STAT
SYNC
ACT
PWR
STAT
L
0
S
L
1
S
L
2
S
L
3
S
L
4
S
L
5
S
L
6
S
L
PWR
7 S
STAT
L
0
S
L
1
S
L
2
S
L
3
S
L
4
S
L
5
S
L
6
S
L
7 S
L
0
S
L
1
S
L
2
S
L
3
S
L
4
S
L
5
S
L
6
S
L
7 S
PWR
STAT
INPUT
OK
OUTPUT
FAIL
24V—60V
28A
INPUT
OK
OUTPUT
FAIL
ALARM
282404
PWR
1
2
2
3
1
USB Type-A console port
2
USB 5-pin mini USB Type-B to USB Type-A
console cable
3
USB Type-A
— —
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
OL-25178-02
3-25
Chapter 3
Connecting the Cisco ASR 903 Series Aggregation Services Router to the Network
Installing the Cisco ASR 903 Series Aggregation Services Router
Connecting to the Console Port using Mac OS X
This procedure describes how to connect a Mac OS X system USB port to the console using the built in
OS X Terminal utility.
Step 1
Use the Finder to go to Applications > Utilities > Terminal.
Step 2
Connect the OS X USB port to the router.
Step 3
Enter the following commands to find the OS X USB port number:
macbook:user$ cd /dev
macbook:user$ ls -ltr /dev/*usb*
crw-rw-rw- 1 root
wheel
DT-macbook:dev user$
Step 4
9,
66 Apr
1 16:46 tty.usbmodem1a21
Connect to the USB port with the following command followed by the router USB port speed
macbook:user$ screen /dev/tty.usbmodem1a21 9600
To disconnect the OS X USB console from the Terminal window
Enter Ctrl-a followed by Ctrl-\
Connecting to the Console Port using Linux
This procedure shows how to connect a Linux system USB port to the console using the built in Linux
Terminal utility.
Step 1
Open the Linux Terminal window.
Step 2
Connect the Linux USB port to the router.
Step 3
Enter the following commands to find the Linux USB port number
root@usb-suse# cd /dev
root@usb-suse /dev# ls -ltr *ACM*
crw-r--r-1 root
root
188,
root@usb-suse /dev#
Step 4
0 Jan 14 18:02 ttyACM0
Connect to the USB port with the following command followed by the router USB port speed
root@usb-suse /dev# screen /dev/ttyACM0 9600
To disconnect the Linux USB console from the Terminal window
Enter Ctrl-a followed by : then quit
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
3-26
OL-25178-02
Chapter 3
Installing the Cisco ASR 903 Series Aggregation Services Router
Connecting the Cisco ASR 903 Series Aggregation Services Router to the Network
Installing the Cisco Microsoft Windows USB Device Driver
A USB device driver must be installed the first time a Microsoft Windows-based PC is connected to the
USB serial port on the router.
This section contains the following topics:
•
“Installing the Cisco Microsoft Windows XP USB Driver”
•
“Installing the Cisco Microsoft Windows 2000 USB Driver”
•
“Installing the Cisco Microsoft Windows Vista USB Driver”
Installing the Cisco Microsoft Windows XP USB Driver
This procedure shows how to install the Microsoft Windows XP USB driver. Download the driver for
your router model from the Tools and Resources Download Software site, USB Console Software
category, at the following URL:
http://tools.cisco.com/support/downloads/go/Redirect.x?mdfid=268437899
Step 1
Unzip the file Cisco_usbconsole_driver_X_X.zip (where X is a revision number).
Step 2
If using 32-bit Windows XP double-click the file setup.exe from the Windows_32 folder, or if using
64-bit Windows XP double-click the file setup(x64).exe from the Windows_64 folder.
Step 3
The Cisco Virtual Com InstallShield Wizard begins. Click Next.
Step 4
The Ready to Install the Program window appears, Click Install.
Step 5
The InstallShield Wizard Completed window appears. Click Finish.
Step 6
Connect the USB cable to the PC and router USB console ports. The EN LED for the USB console port
turns green, and within a few moments the Found New Hardware Wizard appears. Following the
instructions to complete the installation of the driver.
Step 7
The USB console is ready for use.
Installing the Cisco Microsoft Windows 2000 USB Driver
This procedure shows how to install the Microsoft Windows 2000 USB driver.
Step 1
Obtain the file Cisco_usbconsole_driver.zip from the Cisco.com web site and unzip it.
Step 2
Double-click the file setup.exe.
Step 3
The Cisco Virtual Com InstallShield Wizard begins. Click Next.
Step 4
The Ready to Install the Program window appears, Click Install.
Step 5
The InstallShield Wizard Completed window appears. Click Finish.
Step 6
Connect the USB cable to the PC and router USB console ports. The EN LED for the USB console port
turns green, and within a few moments a series of Found New Hardware Wizard windows appear.
Following the instructions to complete the installation of the driver.
Step 7
The USB console is ready for use.
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
OL-25178-02
3-27
Chapter 3
Connecting the Cisco ASR 903 Series Aggregation Services Router to the Network
Installing the Cisco ASR 903 Series Aggregation Services Router
Installing the Cisco Microsoft Windows Vista USB Driver
This procedure shows how to install the Microsoft Windows Vista USB driver.
Step 1
Obtain the file Cisco_usbconsole_driver.zip from the Cisco.com web site and unzip it.
Step 2
If using 32-bit Windows Vista double-click the file setup.exe from the Windows_32 folder, or if using
64-bit Windows Vista double-click the file setup(x64).exe from the Windows_64 folder.
Step 3
The Cisco Virtual Com InstallShield Wizard begins. Click Next.
Step 4
The Ready to Install the Program window appears, Click Install.
Note
If a User Account Control warning appears, click “Allow - I trust this program...” to proceed.
Step 5
The InstallShield Wizard Completed window appears. Click Finish.
Step 6
Connect the USB cable to the PC and router USB console ports. The EN LED for the USB console port
turns green, and within a few moments a pop up window stating “Installing device driver software”
appears. Following the instructions to complete the installation of the driver.
Step 7
The USB console is ready for use.
Uninstalling the Cisco Microsoft Windows USB Driver
This section provides instructions for how to uninstall the Cisco Microsoft Windows USB device driver.
•
“Uninstalling the Cisco Microsoft Windows XP and 2000 USB Driver”
•
“Uninstalling the Cisco Microsoft Windows Vista USB Driver”
Uninstalling the Cisco Microsoft Windows XP and 2000 USB Driver
This procedure shows you how to uninstall both the Microsoft Windows XP and 2000 USB driver. The
driver can be removed using the Windows Add Remove Programs utility or the setup.exe program.
Using the Add Remove Programs Utility
Note
Disconnect the router console terminal before uninstalling the driver.
Step 1
Click Start > Control Panel > Add or Remove Programs.
Step 2
Scroll to Cisco Virtual Com and click Remove.
Step 3
When the Program Maintenance window appears, select the Remove radio button. Click Next.
Using the Setup.exe Program
Note
Disconnect the router console terminal before uninstalling the driver.
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
3-28
OL-25178-02
Chapter 3
Installing the Cisco ASR 903 Series Aggregation Services Router
Connecting the Cisco ASR 903 Series Aggregation Services Router to the Network
Step 1
Run the setup.exe for Windows 32-bit or setup(x64).exe for Windows-64bit. Click Next.
Step 2
The InstallShield Wizard for Cisco Virtual Com appears. Click Next.
Step 3
When the Program Maintenance window appears, select the Remove radio button. Click Next.
Step 4
When the Remove the Program window appears, click Remove.
Step 5
When the InstallShield Wizard Completed window appears click Finish.
Uninstalling the Cisco Microsoft Windows Vista USB Driver
This procedure shows you how to uninstall the Microsoft Windows Vista USB driver.
Note
Disconnect the router console terminal before uninstalling the driver.
Step 1
Run the setup.exe for Windows 32-bit or setup(x64).exe for Windows-64bit. Click Next.
Step 2
The InstallShield Wizard for Cisco Virtual Com appears. Click Next.
Step 3
When the Program Maintenance window appears, select the Remove radio button. Click Next.
Step 4
When the Remove the Program window appears, click Remove.
Note
Step 5
If a User Account Control warning appears, click “Allow - I trust this program...” to proceed.
When the InstallShield Wizard Completed window appears click Finish.
Connecting to the Auxiliary Port
When a modem is connected to the auxiliary port, a remote user can dial in to the router and configure
it. Use a light blue console cable and the DB-9-to-DB-25 connector adapter.
Note
The console cable and DB-9-to-DB-25 connector are not includede with the Cisco ASR 903
Series Aggregation Services Router; they are ordered separately.
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
OL-25178-02
3-29
Chapter 3
Connecting the Cisco ASR 903 Series Aggregation Services Router to the Network
Installing the Cisco ASR 903 Series Aggregation Services Router
To connect a modem to the router, follow these steps:
Step 1
Connect the RJ45 end of the adapter cable to the black AUX port on the router, as shown in Figure 3-22.
Figure 3-22
Connecting a Modem to the Cisco ASR 903 Series Aggregation Services Router
1
MEM
GE-0
GE-1
GE-2
GE-3
GE-4
GE-5
GE-6
GE-7
GE-0
GE-1
GE-2
GE-3
GE-4
GE-5
GE-6
GE-7
PWR
1
1PPS
IN
CONSOLE
RUDY RSP
FAN TEMP
SYNC
STAT
ACT
PWR
PWR
MEM
CONSOLE
1PPS
IN
1PPS
OUT
1OMHZ
IN
1OMHZ
OUT
TOD
BITS
MGMT
ENET
MEM
CONSOLE
1PPS
IN
1PPS
OUT
1OMHZ
IN
1OMHZ
OUT
TOD
BITS
MGMT
ENET
STAT
24V—60V
28A
CRIT MAJ MIN
STAT
STAT
GE-0
GE-1
GE-2
GE-3
GE-4
GE-5
GE-6
GE-7
PWR
RUDY RSP
STAT
SYNC
ACT
PWR
PWR
STAT
L
0
S
L
1
S
L
2
S
L
3
S
L
4
S
L
5
S
L
6
S
L
7 S
L
0
S
L
1
S
L
2
S
L
3
S
L
4
S
L
5
S
L
6
S
L
7 S
L
0
S
L
1
S
L
2
S
L
3
S
L
4
S
L
5
S
L
6
S
L
7 S
STAT
PWR
STAT
INPUT
OK
OUTPUT
FAIL
24V—60V
28A
ALARM
INPUT
OK
OUTPUT
FAIL
282405
PWR
1
2
3
4
1
RJ45 AUX port
3
RJ45 to DB-9
2
DB-9 to DB-25 adapter
4
Modem
Step 2
Connect the DB-9 end of the console cable to the DB-9 end of the modem adapter.
Step 3
Connect the DB-25 end of the modem adapter to the modem.
Step 4
Make sure that your modem and the router auxiliary port are configured for the same transmission speed
(up to 115200 bps is supported) and for mode control with data carrier detect (DCD) and data terminal
ready (DTR) operations.
Connecting a Management Ethernet Cable
When using the Ethernet Management port in the default mode (speed-auto and duplex-auto) the port
operates in auto-MDI/MDI-X mode. The port automatically provides the correct signal connectivity
through the Auto-MDI/MDI-X feature. The port automatically senses a crossover or straight-through
cable and adapts to it.
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
3-30
OL-25178-02
Chapter 3
Installing the Cisco ASR 903 Series Aggregation Services Router
Connecting the Cisco ASR 903 Series Aggregation Services Router to the Network
However, when the Ethernet Management port is configured to a fixed speed (10 or 100 Mbps) through
command-line interface (CLI) commands, the port is forced to MDI mode.
When in a fixed-speed configuration and MDI mode:
•
Use a crossover cable to connect to an MDI port
•
Use a straight-through cable to connect to an MDI-X port
Installing and Removing SFP and XFP Modules
The Cisco ASR 903 Series Aggregation Services Router supports a variety of SFP and XFP modules,
including optical and Ethernet modules. For information on how to install and remove SFP and XFP
modules, see the documentation for the SFP or XFP module at
http://www.cisco.com/en/US/partner/products/hw/modules/ps5455/prod_installation_guides_list.html
For information about inspecting and cleaning fiber-optic connections, see
http://www.cisco.com/en/US/partner/tech/tk482/tk876/technologies_white_paper09186a0080254eba.s
html
Connecting a USB Flash Device
To connect a USB flash device to the Cisco ASR 903 Series Aggregation Services Router, insert the
memory stick in the USB port labeled MEM. The Flash memory module can be inserted in only one way,
and can be inserted or removed regardless of whether the router is powered up or not.
Figure 3-23 shows the USB port connector on the Cisco ASR 903 Series Aggregation Services Router.
Figure 3-23
Cisco ASR 903 Series Aggregation Services Router Flash Token Memory Stick
CONSOL
E
209390
MEM
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
OL-25178-02
3-31
Chapter 3
Connecting the Cisco ASR 903 Series Aggregation Services Router to the Network
Installing the Cisco ASR 903 Series Aggregation Services Router
Removing a USB Flash Device
To remove and then replace a USB flash token memory stick from a Cisco ASR 903 Series Aggregation
Services Router, follow these steps:
Step 1
Pull the memory stick from the USB port.
Step 2
To replace a Cisco USB Flash memory stick, simply insert the module into the USB port labeled MEM
as shown in Figure 3-23 . The Flash memory module can be inserted in only one way, and can be inserted
or removed regardless of whether the router is powered up or not.
Note
You can insert or remove the memory stick whether the router is powered on or not.
This completes the USB Flash memory installation procedure.
Connecting Timing Cables
The following sections describe how to connect timing cables to the Cisco ASR 903 Series Aggregation
Services Router:
•
Connecting Cables to the BITS Interface, page 3-32
•
Connecting Cables to a GPS Interface, page 3-33
Connecting Cables to the BITS Interface
The following steps describe how to connect a cable to the router BITS port:
Step 1
Confirm that the router is powered off.
Step 2
Connect one end of the cable to the BITS port using a straight-through, shielded RJ48C-to-RJ48C cable.
Step 3
Connect the other end to the BTS patch or demarcation panel at your site.
Step 4
Turn on power to the router (see "Powering On the Router" section for more details).
For information about the BITS port pinouts, see Chapter 5, “Troubleshooting.”
Note
Use of two BITS sources or a Y-cable is optional. Each BITS input port is routed to both RSPs,
so that SETS device on each RSP has visibility to both BITS inputs.
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
3-32
OL-25178-02
Chapter 3
Installing the Cisco ASR 903 Series Aggregation Services Router
Connecting the Cisco ASR 903 Series Aggregation Services Router to the Network
Connecting Cables to a GPS Interface
The following sections describe how to connect cables from the Cisco ASR 903 Series Aggregation
Services Router to a GPS unit for input or output timing of frequency:
Note
•
Connecting Cables to the Input 10Mhz or 1PPS Interface, page 3-33
•
Connecting Cables to the Output 10Mhz or 1PPS Interface, page 3-33
•
Connecting Cables to the ToD Interface, page 3-33
A Y-cable is required to connect to a primary and backup RSP in order to ensure that the router continues
to transmit timing signals in the event of a network failure. For a mini-coax connection, this Y-cable can
be part number CAB-BNC-7INY (7 inch BNC Y-cable). For an Ethernet connection, this Y-cable can be
a RJ45 Cat5 1-to-2 splitter (3 female port RJ45 connector).
Connecting Cables to the Input 10Mhz or 1PPS Interface
Step 1
Connect one end of a mini-coax Y-cable to the GPS unit.
Step 2
Connect one end of the split-side Y-cable mini-coax to the 10Mhz or 1PPS port on the primary RSP of
the Cisco ASR 903 Series Aggregation Services Router.
Step 3
Connect the other end of the split-side Y-cable mini-coax to the 10Mhz or 1PPS port on the backup RSP
of the Cisco ASR 903 Series Aggregation Services Router.
Connecting Cables to the Output 10Mhz or 1PPS Interface
Step 1
Connect one end of a mini-coax Y-cable to the Slave unit.
Step 2
Connect one end of the split-side Y-cable mini-coax to the 10Mhz or 1PPS port on the primary RSP of
the Cisco ASR 903 Series Aggregation Services Router.
Step 3
Connect the other end of the split-side Y-cable mini-coax to the 10Mhz or 1PPS port on the backup RSP
of the Cisco ASR 903 Series Aggregation Services Router.
Connecting Cables to the ToD Interface
Step 1
Connect one end of a straight-through Ethernet cable to the GPS unit.
Step 2
Connect one end of the split-side Y-cable Ethernet to the ToD port on the primary RSP of the Cisco ASR
903 Series Aggregation Services Router.
Step 3
Connect the other end of the split-side Y-cable Ethernet to the ToD port on the backup RSP of the Cisco
ASR 903 Series Aggregation Services Router.
Note
For instructions on how to configure clocking, see the Cisco ASR 903 Series Aggregation Services
Router Software Configuration Guide.
Note
For more information about GPS port pinouts, see Chapter 5, “Troubleshooting.”
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
OL-25178-02
3-33
Chapter 3
Connecting the Cisco ASR 903 Series Aggregation Services Router to the Network
Installing the Cisco ASR 903 Series Aggregation Services Router
Connecting Ethernet Cables
The Cisco ASR 903 Series Aggregation Services Router interface modules support RJ45 or SFP Ethernet
ports. For instructions on how to connect cables to Ethernet SFP ports, see Connecting Cables to SFP
Modules, page 3-34.
The RJ45 port supports standard straight-through and crossover Category 5 unshielded twisted-pair
(UTP) cables. Cisco Systems does not supply Category 5 UTP cables; these cables are available
commercially.
Follow these steps to connect the cable to a copper Gigabit Ethernet port:
Step 1
Confirm that the router is powered off.
Step 2
Connect one end of the cable to the Gigabit Ethernet port on the router.
Step 3
Connect the other end to the BTS patch or demarcation panel at your site.
Connecting Cables to SFP Modules
For information on connecting cables to Cisco optical and Ethernet SFP interfaces, see
http://www.cisco.com/en/US/partner/products/hw/modules/ps5455/prod_installation_guides_list.html.
Connecting T1/E1 cables
The physical layer interface for the Cisco ASR 903 Series Aggregation Services Router T1/E1 port is a
customer-installed high-density connector. The high-density connector has thumbscrews which should
be screwed into the interface when the cable is installed.
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
3-34
OL-25178-02
Chapter 3
Installing the Cisco ASR 903 Series Aggregation Services Router
Connecting the Cisco ASR 903 Series Aggregation Services Router to the Network
Figure 3-24 shows the T1/E1 cable connector and Figure 3-25 shows the connection between the T1/E1
interface and the patch panel.
Note
A patch panel is required in order to connect the high-density interface connector to individual T1/E1
lines.
Figure 3-24
T1/E1 Cable Connector
Pin 50
Pin
50
Pin
100
Pin
1
Pin
51
RX
Pin
1
Pin 50
282349
TX
Pin
1
Installing the Cable Connector
One end of the cable has a 100-pin connector that plugs into the T1/E1 interface module. Use the
thumbscrews on either side of the connector to secure the cable to the interface.
The other end of the cable has two 50-pin Telco connectors that attach to the rear of a 24-port RJ45 patch
panel. Both connectors are identical: one is for Transmit (TX) and the other is for Receive (RX).
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
OL-25178-02
3-35
Chapter 3
Connecting the Cisco ASR 903 Series Aggregation Services Router to the Network
Installing the Cisco ASR 903 Series Aggregation Services Router
Figure 3-25 shows how the cable is connected between the T1/E1 interface module and the patch panel.
Figure 3-25
Cable Installation between T1/E1 Interface and Patch Panel
1
PORTS
1-16
TRANS
MIT
RECEIV
255735
E
1
Patch panel interfaces
For information about the pinout of the cable connecting the T1/E1 interface to the rear of the patch
panel, see the “T1/E1 Port Pinout” section on page 5-4.
RJ45 Cable Pinouts
T1 lines from individual subscribers are attached to RJ45 connectors on the front of the 24-port patch
panel. Each RJ45 port accommodates an individual T1 subscriber line.
For the for the T1/E1 ports, see the “T1/E1 Port Pinout” section on page 5-4.
Connecting Cables to the Patch Panel
If you are connecting two T1/E1 interfaces to each other, you must cable both interfaces’ patch panels
together using a T1 cross-over cable or a T1 straight-through cable. Use shielded cables. The type of
cable you use (cross-over or straight-through) depends on how the T1/E1 interfaces are cabled to their
patch panels:
•
If both T1/E1 interfaces are connected to their patch panels in the same manner (TX to Transmit and
RX to Receive, or TX to Receive and RX to Transmit), use a T1 cross-over cable to connect the patch
panels.
•
If both T1/E1 interfaces are connected to their patch panels in a different configuration (TX to
Transmit and RX to Receive on one interface, and TX to Receive and RX to Transmit on the other
interface), use a T1 straight-through cable (standard RJ45 patch cable) to connect the patch panels.
Recommended Patch Panel
We recommend the following T1/E1 patch panels:
48-port T1 RJ45 patch panel (part number DCC4884/25T1-S)
16-port E1 BNC patch panel (part number DCC16BNC/25T1-S)
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
3-36
OL-25178-02
Chapter 3
Installing the Cisco ASR 903 Series Aggregation Services Router
Connecting the Cisco ASR 903 Series Aggregation Services Router to the Network
The patch panels are available from Optical Cable Corporation (http://www.occfiber.com). To order a
patch panel, contact the Sales and Marketing Support staff at Optical Cable Corporation:
•
800-622-7711 (toll-free in the U.S.A.)
•
540-265-0690 (outside the U.S.A.)
Connecting the Fan Tray Alarm Port
The fan tray includes an alarm port that maps to 4 dry contact alarm inputs.
The pins on the alarm port are passive signals and can be configured as Normally Open (an alarm
generated when current is interrupted) or Normally Closed (an alarm is generated when a circuit is
established) alarms. You can configure each alarm input as critical, major, or minor. An alarm triggers
alarm LEDs and alarm messages. The relay contacts can be controlled through any appropriate
third-party relay controller. The open/close configuration is an option controlled in IOS.
Only Pins 1, 2, 4, 6, and 8 are available for customer use. The remaining pins are for Cisco manufacturing
test, and should not be connected. Use a shielded cable for connection to this port for EMC protection.
Table 5-4 summarizes the pinouts on the alarm port in Chapter 5, “Troubleshooting.”
Step 1
Attach an RJ45 cable to the alarm port.
Step 2
Attach the other end of the RJ45 cable to the relay controller.
For information about how to map alarm inputs to critical, major, and minor alarm conditions, see the
Cisco ASR 903 Series Aggregation Services Router Software Configuration Guide.
Connector and Cable Specifications
For more information on cable specifications and pinouts, see Chapter 5, “Troubleshooting”.
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
OL-25178-02
3-37
Chapter 3
Connecting the Cisco ASR 903 Series Aggregation Services Router to the Network
Installing the Cisco ASR 903 Series Aggregation Services Router
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
3-38
OL-25178-02
CH A P T E R
4
Cisco ASR 903 Series Aggregation Services
Router Initial Configuration
This chapter guides you through a basic router configuration, which is sufficient for you to access your
network. Complex configuration procedures are beyond the scope of this publication and can be found
in the modular configuration and modular command reference publications in the Cisco IOS software
configuration documentation set that corresponds to the software release installed on your Cisco
hardware.
To configure the Cisco ASR 903 Series Aggregation Services Router from a console, you need to
connect a terminal to the router console port.
This chapter contains the following sections:
•
Checking Conditions Prior to System Startup, page 4-1
•
Powering Up the Cisco ASR 903 Series Aggregation Services Router, page 4-2
•
Configuring the Cisco ASR 903 Series Aggregation Services Router at Startup, page 4-6
•
Safely Powering Off the Cisco ASR 903 Series Aggregation Services Router, page 4-8
Checking Conditions Prior to System Startup
Ensure that the following conditions are addressed before starting up the router:
•
The Route Switch Processor (RSP) is installed.
•
The network interface cable is connected to the RSP.
•
The optional Gigabit Ethernet Management port cable is installed.
•
The chassis is securely mounted and grounded.
•
The power and interface cables are connected.
•
Your PC with terminal emulation program (hyperTerminal or equivalent) is connected to the console
port and powered up.
•
Your PC terminal emulation program is configured for 9600 baud, 8 data bits, 1 stop-bit, no parity,
and flow control is set to none.
•
You have selected passwords for access control.
•
Captive installation screws are tight on all removable components.
•
The console terminal is turned on.
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
OL-25178-02
4-1
Chapter 4
Cisco ASR 903 Series Aggregation Services Router Initial Configuration
Powering Up the Cisco ASR 903 Series Aggregation Services Router
•
You have determined the IP addresses for the Ethernet and serial interfaces.
•
Empty card slots or card bays are filled with card blanks. This ensures proper air flow through the
chassis and electromagnetic compatibility (EMC).
Powering Up the Cisco ASR 903 Series Aggregation Services
Router
Make certain that all card slots and compartments are closed off. Install blank faceplates on any empty
slots. Always have power supply slots filled. If you leave a power supply slot uncovered, then you risk
exposure to hazardous voltages on the power pins on the midplane.
Warning
Blank faceplates and cover panels serve three important functions: they prevent exposure to
hazardous voltages and currents inside the chassis; they contain electromagnetic interference (EMI)
that might disrupt other equipment; and they direct the flow of cooling air through the chassis. Do not
operate the system unless all cards, faceplates, front covers, and rear covers are in place. Statement
1029
After installing your Cisco ASR 903 Series Aggregation Services Router and connecting cables, start
the router and follow these steps:
Step 1
Activate the DC power supply using the steps described in “Activating the DC Power Supply” procedure
on page 3-21.
Caution
Note
Step 2
Do not press any keys on the keyboard until the messages stop and the SYS PWR LED is solid
green. Any keys pressed during this time are interpreted as the first command typed when the
messages stop, which might cause the router to power off and start over. It takes a few minutes
for the messages to stop.
This is only an example of what can display. The system boots differently depending upon
the configuration that ships with your system.
Observe the initialization process. When the system boot is complete (the process takes a few seconds),
the Cisco ASR 903 Series Aggregation Services Router RSP begins to initialize.
Example 4-1
Loading the Default System Boot Image
rommon 1 >
rommon 1 > boot
Located rp_super.ppc.nader.5g.evfc.bin
Image size 211681484 inode num 12, bks cnt 51681 blk size 8*512
######################################################################################
#
#############################################
Boot image size = 211681484 (0xc9e00cc) bytes
Using midplane macaddr
Package header rev 0 structure detected
Calculating SHA-1 hash...done
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
4-2
OL-25178-02
Chapter 4
Cisco ASR 903 Series Aggregation Services Router Initial Configuration
Powering Up the Cisco ASR 903 Series Aggregation Services Router
validate_package: SHA-1 hash:
calculated 479a7d62:6c128ba8:3616b8da:93cb3224:5c1aeb34
expected
479a7d62:6c128ba8:3616b8da:93cb3224:5c1aeb34
Image validated
PPC/IOS XE loader version: 0.0.3
loaded at:
00800000 0D1E2004
zimage at:
00807673 009B8C69
initrd at:
009B9000 01006219
isord at:
01007000 0D1DF800
avail ram:
00400000 00800000
Kernel load:
Uncompressing image... dst: 00000000 lim: 00400000 start: 00807673 size:
001B15F6...done.
Now booting the IOS XE kernel
Restricted Rights Legend
Use, duplication, or disclosure by the Government is
subject to restrictions as set forth in subparagraph
(c) of the Commercial Computer Software - Restricted
Rights clause at FAR sec. 52.227-19 and subparagraph
(c) (1) (ii) of the Rights in Technical Data and Computer
Software clause at DFARS sec. 252.227-7013.
cisco Systems, Inc.
170 West Tasman Drive
San Jose, California 95134-1706
Router# show version
Cisco IOS Software, IOS-XE Software (PPC_LINUX_IOSD-ADVENTERPRISEK9-M), Version
12.2(33)XNA, RELEASE SOFTWARE
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2008 by Cisco Systems, Inc.
Compiled Thu 01-May-08 00:29 by mcpre
Cisco IOS-XE software, Copyright (c) 1986-2008 by Cisco Systems, Inc.
All rights reserved. Certain components of Cisco IOS-XE software are
licensed under the GNU General Public License ("GPL") Version 2.0. The
software code licensed under GPL Version 2.0 is free software that comes
with ABSOLUTELY NO WARRANTY. You can redistribute and/or modify such
GPL code under the terms of GPL Version 2.0. For more details, see the
documentation or "License Notice" file accompanying the IOS-XE software,
or the applicable URL provided on the flyer accompanying the IOS-XE
software.
A summary of U.S. laws governing Cisco cryptographic products may be found at:
http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
If you require further assistance please contact us by sending email to
export@cisco.com.
cisco ASR903 processor with 541737K/6147K bytes of memory.
4 Gigabit Ethernet interfaces
32768K bytes of non-volatile configuration memory.
1869396K bytes of physical memory.
7798783K bytes of eUSB flash at bootflash:.
--- System Configuration Dialog ---
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
OL-25178-02
4-3
Chapter 4
Cisco ASR 903 Series Aggregation Services Router Initial Configuration
Powering Up the Cisco ASR 903 Series Aggregation Services Router
Would you like to enter the initial configuration dialog? [yes/no]: no
Press RETURN to get started!
*Feb 19
*Feb 19
created
*Feb 19
17:34:27.361:
17:34:28.235:
with ID 4085,
17:34:29.720:
% Error opening nvram:/ifIndex-table No such file or directory
%ASR1000_MGMTVRF-6-CREATE_SUCCESS_INFO: Management vrf Mgmt-intf
ipv4 table-id 0xFF5, ipv6 table-id 0x1E000001
%PARSER-4-BADCFG: Unexpected end of configuration file.
*Feb 19 17:34:29.809: %NETCLK-5-NETCLK_MODE_CHANGE: Network clock source not
available. The network clock has changed to freerun
*Feb 19 17:34:10.138: %CPPHA-7-SYSREADY: F0: cpp_ha: CPP client process FMAN-FP (5 of
5) ready.
*Feb 19 17:34:29.824: %LINK-3-UPDOWN: Interface GigabitEthernet0, changed state to up
*Feb 19 17:34:10.269: %IOSXE-6-PLATFORM: F0: cpp_cp: cpp_mlp_svr_client_bind:
cpp_mlp_svr_ifm_init() successful
*Feb 19 17:34:10.362: %CPPHA-7-START: F0: cpp_ha: CPP 0 preparing image
/usr/cpp/bin/cpp-mcplo-ucode
*Feb 19 17:34:10.473: %CPPHA-7-START: F0: cpp_ha: CPP 0 startup init image
/usr/cpp/bin/cpp-mcplo-ucode
*Feb 19 17:34:14.688: %CPPHA-7-START: F0: cpp_ha: CPP 0 running init image
/usr/cpp/bin/cpp-mcplo-ucode
*Feb 19 17:34:14.919: %CPPHA-7-READY: F0: cpp_ha: CPP 0 loading and initialization
complete
*Feb 19 17:34:14.919: %CPPHA-6-SYSINIT: F0: cpp_ha: CPP HA system configuration
start.
*Feb 19 17:34:15.179: %IOSXE-6-PLATFORM: F0: cpp_cp: Process
CPP_PFILTER_EA_EVENT__API_CALL__REGISTER
*Feb 19 17:34:15.286: %CPPHA-6-SYSINIT: F0: cpp_ha: CPP HA system enabled.
*Feb 19 17:34:15.287: %CPPHA-6-SYSINIT: F0: cpp_ha: CPP HA system initializaton
complete.
*Feb 19 17:34:30.823: %LINEPROTO-5-UPDOWN: Line protocol on Interface
GigabitEthernet0, changed state to down
*Feb 19 17:35:12.865: %LINK-5-CHANGED: Interface GigabitEthernet0/0/0, changed state
to administratively down
*Feb 19 17:35:12.865: %LINK-5-CHANGED: Interface GigabitEthernet0/0/1, changed state
to administratively down
*Feb 19 17:35:12.865: %LINK-5-CHANGED: Interface GigabitEthernet0/0/2, changed state
to administratively down
*Feb 19 17:35:12.865: %LINK-5-CHANGED: Interface GigabitEthernet0/0/3, changed state
to administratively down
*Feb 19 17:35:13.865: %LINEPROTO-5-UPDOWN: Line protocol on Interface
GigabitEthernet0/0/0, changed state to down
*Feb 19 17:35:13.865: %LINEPROTO-5-UPDOWN: Line protocol on Interface
GigabitEthernet0/0/1, changed state to down
*Feb 19 17:35:13.866: %LINEPROTO-5-UPDOWN: Line protocol on Interface
GigabitEthernet0/0/2, changed state to down
*Feb 19 17:35:13.866: %LINEPROTO-5-UPDOWN: Line protocol on Interface
GigabitEthernet0/0/3, changed state to down
*Feb 19 17:35:19.167: %ASR1000_OIR-6-REMSPA: SPA removed from subslot 0/0, interfaces
disabled
*Feb 19 17:35:19.171: %ASR1000_OIR-6-INSCARD: Card (fp) inserted in slot F0
*Feb 19 17:35:19.171: %ASR1000_OIR-6-ONLINECARD: Card (fp) online in slot F0
*Feb 19 17:35:19.187: %ASR1000_OIR-6-INSCARD: Card (cc) inserted in slot 0
*Feb 19 17:35:19.187: %ASR1000_OIR-6-ONLINECARD: Card (cc) online in slot 0
*Feb 19 17:35:19.189: %ASR1000_OIR-6-INSSPA: SPA inserted in subslot 0/0
*Feb 19 17:35:19.452: %SYS-5-RESTART: System restarted -Cisco IOS Software, IOS-XE Software (PPC_LINUX_IOSD-ADVENTERPRISEK9-M), Version
12.2(33)XNA, RELEASE SOFTWARE
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2008 by Cisco Systems, Inc.
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
4-4
OL-25178-02
Chapter 4
Cisco ASR 903 Series Aggregation Services Router Initial Configuration
Powering Up the Cisco ASR 903 Series Aggregation Services Router
Compiled Thu 20-Dec-07 18:10 by mcpre
*Feb 19 17:35:19.455: %SYS-6-BOOTTIME: Time taken to reboot after reload = 78809
seconds
*Feb 19 17:35:19.551: %CRYPTO-6-ISAKMP_ON_OFF: ISAKMP is OFF
*Feb 19 17:35:19.551: %CRYPTO-6-ISAKMP_ON_OFF: ISAKMP is OFF
*Feb 19 17:35:21.669: %DYNCMD-7-CMDSET_LOADED: The Dynamic Command set has been loaded
from the Shell Manager
*Feb 19 17:35:22.221: %CRYPTO-6-ISAKMP_ON_OFF: ISAKMP is OFF
Router>
During the boot process, observe the system LEDs. The LEDs on the shared port adapter go on and off
in an irregular sequence. Once the router has booted, the green STATUS LED comes on and stays on.
Verifying the Front Panel LEDs
The front-panel indicator LEDs provide power, activity, and status information useful during bootup. For
more detailed information about the LEDs, see Chapter 5, “Troubleshooting.”
Verifying the Hardware Configuration
To display and verify the hardware features, enter the following commands:
•
show version—Displays the system hardware version; the installed software version; the names and
sources of configuration files; the boot images; and the amount of installed DRAM, NVRAM, and
flash memory.
•
show diag slot—Displays the IDPROM information for the assemblies in the chassis.
Checking Hardware and Software Compatibility
To check the minimum software requirements of the Cisco IOS software with the hardware installed on
your Cisco ASR 903 Series Aggregation Services Router, Cisco maintains the Software Advisor tool on
Cisco.com. The tool provides the minimum Cisco IOS requirements for individual hardware modules
and components.
Note
To access this tool, you must have a Cisco.com login account.
To access the Software Advisor, click Login at Cisco.com, type Software Advisor in the search box,
and click Go. Click the link for the Software Advisor Tool.
Choose a product family or enter a specific product number to search for the minimum supported
software needed for your hardware.
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
OL-25178-02
4-5
Chapter 4
Configuring the Cisco ASR 903 Series Aggregation Services Router at Startup
Cisco ASR 903 Series Aggregation Services Router Initial Configuration
Configuring the Cisco ASR 903 Series Aggregation Services
Router at Startup
This section explains how to create a basic running configuration for your Cisco ASR 903 Series
Aggregation Services Router.
Note
You need to acquire the correct network addresses from your system administrator or consult
your network plan to determine correct addresses before you can complete the router
configuration.
Before continuing the configuration process, check the current state of the router by entering the show
version command. The show version command displays the release of Cisco IOS software that is
available on the router.
For information on modifying the configuration after you create it, see the Cisco IOS configuration and
command reference guides.
To configure a Cisco ASR 903 Series Aggregation Services Router from the console, you must connect
a terminal or terminal server to the console port on the Cisco ASR 903 Series Aggregation Services
Router RSP. To configure the Cisco ASR 903 Series Aggregation Services Router using the management
Ethernet port, you must have the router’s IP address available.
Using the Console Interface
To access the command line interface using the console, follow these steps:
Step 1
Your system is booting and if you answer No, at the prompt:
--- System Configuration Dialog --Would you like to enter the initial configuration dialog? [yes/no]: no
Step 2
Then Press Return to enter user EXEC mode. The following prompt appears:
Router>
Step 3
From user EXEC mode, enter the enable command as shown in the following example:
Router> enable
Step 4
At the password prompt, enter your system password. If an enable password has not been set on your
system, this step may be skipped. The following example shows entry of the password called enablepass:
Password: enablepass
Step 5
When your enable password is accepted, the privileged EXEC mode prompt appears: Router#
Step 6
You now have access to the CLI in privileged EXEC mode and you can enter the necessary commands
to complete your desired tasks. To exit the console session, enter the quit command as shown in the
following example:
Router# quit
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
4-6
OL-25178-02
Chapter 4
Cisco ASR 903 Series Aggregation Services Router Initial Configuration
Configuring the Cisco ASR 903 Series Aggregation Services Router at Startup
Configuring Global Parameters
When you first start the setup program, you must configure the global parameters. These parameters are
used for controlling system-wide settings. Perform the following steps to enter the global parameters:
Step 1
Connect a console terminal to the console port, and then boot the router.
This is only an example of the output display; prompts may vary.
Note
When you see this information, you have successfully booted your router:
Restricted Rights Legend
Use, duplication, or disclosure by the Government is
subject to restrictions as set forth in subparagraph
(c) of the Commercial Computer Software - Restricted
Rights clause at FAR sec. 52.227-19 and subparagraph
(c) (1) (ii) of the Rights in Technical Data and Computer
Software clause at DFARS sec. 252.227-7013.
cisco Systems, Inc.
170 West Tasman Drive
San Jose, California 95134-1706
.
.
.
--- System Configuration Dialog --Would you like to enter the initial configuration dialog? [yes/no]: yes
Press RETURN to get started!
Step 2
The first sections of the configuration script appear only at an initial system startup. On subsequent uses
of the setup facility, the script begins with a System Configuration Dialog as shown below: When asked
if you would like to enter the initial configuration dialog, enter yes.
Would you like to enter the initial configuration dialog? [yes/no] yes
At any point you may enter a question mark '?' for help.
Use ctrl-c to abort configuration dialog at any prompt.
Default settings are in square brackets '[]'.
Basic management setup configures only enough connectivity for management of the
system, extended setup will ask you to configure each interface on the system.
Basic management setup configures enough connectivity for managing the system; extended setup will
ask you to configure each interface on the system. For detailed information about setting global
parameters, refer to the Cisco ASR 903 Series Aggregation Services Router Software Configuration
Guide.
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
OL-25178-02
4-7
Chapter 4
Safely Powering Off the Cisco ASR 903 Series Aggregation Services Router
Cisco ASR 903 Series Aggregation Services Router Initial Configuration
Checking the Running Configuration Settings
To check the value of the settings you have entered, enter the show running-config command at the
prompt:
Router#
Router# show running-config
To review changes you make to the configuration, use the EXEC mode show startup-config command
to see the changes and copy run-start stored in NVRAM.
Saving the Running Configuration to NVRAM
To store the configuration or changes to your startup configuration in NVRAM, enter the copy
running-config startup-config command at the Router# prompt:
Router# copy running-config startup-config
Using this command saves the configuration settings that you created in the router using configuration
mode and the setup facility. If you fail to do this, your configuration will be lost the next time you reload
the router.
Safely Powering Off the Cisco ASR 903 Series Aggregation
Services Router
This section explains how to shut down the Cisco ASR 903 Series Aggregation Services Router. It is
recommended that before turning off all power to the chassis, you issue the reload command. This
insures that the operating system cleans up all the file systems. Once the reload operation is complete,
then the Cisco ASR 903 Series Aggregation Services Router can be powered off safely.
To remove power from the Cisco ASR 903 Series Aggregation Services Router safely, follow this
procedure and see the examples:
Step 1
Slip on the ESD-preventive wrist strap that was included in the accessory kit.
Step 2
Enter the reload command.
Step 3
Confirm the reload command.
Rmcp-6ru-1#reload
Proceed with reload? [confirm]
Aug 17 00:06:47.051 R0/0: %PMAN-5-EXITACTION: Process manager is exiting: prs exit
with reload chassis code
Step 4
After confirming the reload command, wait until the system bootstrap message displays before powering
off the system.
System Bootstrap, Version 12.2(33r)XN2, RELEASE SOFTWARE (fc1)
Technical Support: tap://www.cisco.com/techsupport
Copyright (c) 2008 by cisco Systems, Inc.
Current image running: Boot ROM0
Last reset cause: LocalSoft
ASR1000-RP1 platform with 4194303 Kbytes of main memory
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
4-8
OL-25178-02
Chapter 4
Cisco ASR 903 Series Aggregation Services Router Initial Configuration
Safely Powering Off the Cisco ASR 903 Series Aggregation Services Router
mcp-6ru-1-rp0-rommon 1>
Step 5
Note
Remove any power cables from the Cisco ASR 903 Series Aggregation Services Router.
a.
For power supplies with a circuit breaker switch, position the switch to the Off (O) position.
b.
For power supplies with a Standby switch, place the Standby switch in the Standby position.
After powering off the router, wait a minimum of 30 seconds before powering it on again.
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
OL-25178-02
4-9
Chapter 4
Safely Powering Off the Cisco ASR 903 Series Aggregation Services Router
Cisco ASR 903 Series Aggregation Services Router Initial Configuration
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
4-10
OL-25178-02
CH A P T E R
5
Troubleshooting
The following sections provide information for troubleshooting problems on the Cisco ASR 903 Series
Router.
•
Pinouts, page 5-1
•
LED Summary, page 5-7
Pinouts
The following sections describe the pinouts for the Cisco ASR 903 Series Router interfaces:
•
BITS Port Pinout, page 5-1
•
GPS Port Pinout, page 5-2
•
Time of Day Port Pinout, page 5-2
•
Alarm Port Pinout, page 5-3
•
Console/Aux RJ45 RS232 Serial Port Pinout, page 5-3
•
T1/E1 Port Pinout, page 5-4
•
Management Ethernet Port Pinout, page 5-5
•
USB Console Port Pinout, page 5-6
•
Fiber-Optic Specifications, page 5-7
BITS Port Pinout
Table 5-1 summarizes the BITS port pinout.
Table 5-1
BITS Port Pinout
Pin
Signal Name
Direction
Description
1
RX Ring
Input
Receive Ring
2
RX Tip
Input
Receive Tip
3
Not used
4
TX Ring
Output
TX Ring
5
TX Tip
Output
TX Tip
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
OL-25178-02
5-1
Chapter 5
Troubleshooting
Pinouts
Table 5-1
Pin
BITS Port Pinout (continued)
Signal Name
Direction
Description
6
Not used
7
Not used
8
Not used
GPS Port Pinout
Table 5-2 summarizes the GPS port pinouts.
Table 5-2
GPS Port Pinout
10 Mhz (input and output)
1PPS (input and output)
Input—Sine wave
Input—Pulse shape
Output—Square wave
Output—Pulse shape
Input— > 1.7 volt p-p
(+8 to +10 dBm)
Input— > 2.4 volts TTL
compatible
Output— > 2.4 volts TTL
compatible
Output— > 2.4 volts TTL
compatible
Impedance
50 ohms
50 ohms
Pulse Width
50% duty cycle
26 microseconds
Rise Time
Input—AC coupled
40 nanoseconds
Waveform
Amplitude
Output—5 nanoseconds
Time of Day Port Pinout
Table 5-3 summarizes the ToD/1PPS port pinout.
Table 5-3
RJ45 1PPS/ToD Port Pinout
Pin
Signal Name
Direction
Description
1
1PPS_P
Output or Input
1PPS RS422
signal
2
1PPS_N
Output or Input
1PPS RS422
signal
3
RESERVED
Output
Do NOT connect
4
GND
5
GND
6
RESERVED
Time of Day
character
Input
Do NOT connect
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
5-2
OL-25178-02
Chapter 5
Troubleshooting
Pinouts
Table 5-3
RJ45 1PPS/ToD Port Pinout (continued)
Pin
Signal Name
Direction
Description
7
TOD_P
Output or Input
Time of Day
character
8
TOD_N
Output or Input
Time of Day
character
Alarm Port Pinout
Table 5-4 summarizes the external alarm input pinout.
Table 5-4
External Alarm Input Pinout
Pin
Signal Name
Description
1
ALARM0_IN
Alarm input 0
2
ALARM1_IN
Alarm input 1
3
No connect
4
ALARM2_IN
Alarm input 2
5
ALARM3_IN
Alarm input 3
6
No connect
7
No connect
8
COMMON
Alarm common
Console/Aux RJ45 RS232 Serial Port Pinout
Table 5-5 summarizes the console/aux RJ45 RS232 serial port pinout.
Table 5-5
Console/Aux RJ45 RS232 serial port
Pin
Signal Name
Direction
Description
1
RTS
Output
Request to send
2
DTR
Output
Data Terminal Ready (always On).
3
TXD
Output
Transmit data
4
RI
5
GND
6
RXD
Input
Receive data
7
DSR/DCD
Input
Data set ready/Data Carrier detect
8
CTS
Input
Clear to send
Ring Indicator
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
OL-25178-02
5-3
Chapter 5
Troubleshooting
Pinouts
T1/E1 Port Pinout
Table 5-6 summarizes the pinouts of the cable (Tyco part number 2163442-1, Cisco part number
72-5184-01) used to connect the T1/E1 interface module to the rear of the patch panel.
Table 5-6
T1/E1 Interface Pinouts
Line
Board
Pins
Signal Name
Line 0
51
Line 1
Line 2
Line 3
Line 4
Line 5
Line 6
Line 7
Line 8
Line 9
Line 10
Line 11
Line 12
Line 13
Line 14
Telco
TX
Jack Pin
Board
Pins
Signal Name
Telco RX
Jack Pin
TX_RING_P12 26
1
55
RX_RING_P12
26
4
1
TX_TIP_P12
2
5
RX_TIP_P12
1
5
52
TX_RING_P11 27
1
56
RX_RING_P11
27
4
2
TX_TIP_P11
2
6
RX_TIP_P11
2
5
61
TX_RING_P16 28
1
57
RX_RING_P16
28
4
11
TX_TIP_P16
2
7
RX_TIP_P16
3
5
62
TX_RING_P15 29
1
58
RX_RING_P15
29
4
12
TX_TIP_P15
2
8
RX_TIP_P15
4
5
63
TX_RING_P10 30
1
67
RX_RING_P10
30
4
13
TX_TIP_P10
5
2
17
RX_TIP_P10
5
5
64
TX_RING_P9
31
1
68
RX_RING_P9
31
4
14
TX_TIP_P9
6
2
18
RX_TIP_P9
6
5
73
TX_RING_P14 32
1
69
RX_RING_P14
32
4
23
TX_TIP_P14
2
19
RX_TIP_P14
7
5
74
TX_RING_P13 33
1
70
RX_RING_P13
33
4
24
TX_TIP_P13
8
2
20
RX_TIP_P13
8
5
75
TX_RING_P4
34
1
79
RX_RING_P4
34
4
25
TX_TIP_P4
9
2
29
RX_TIP_P4
9
5
76
TX_RING_P3
35
1
80
RX_RING_P3
35
4
26
TX_TIP_P3
10
2
30
RX_TIP_P3
10
5
85
TX_RING_P8
36
1
81
RX_RING_P8
36
4
35
TX_TIP_P8
11
2
31
RX_TIP_P8
11
5
86
TX_RING_P7
37
1
82
RX_RING_P7
37
4
36
TX_TIP_P7
12
2
32
RX_TIP_P7
12
5
87
TX_RING_P2
38
1
91
RX_RING_P2
38
4
37
TX_TIP_P2
13
2
41
RX_TIP_P2
13
5
88
TX_RING_P1
39
1
92
RX_RING_P1
39
4
38
TX_TIP_P1
14
2
42
RX_TIP_P1
14
5
99
TX_RING_P6
40
1
93
RX_RING_P6
40
4
49
TX_TIP_P6
15
2
43
RX_TIP_P6
15
5
1
2
3
4
7
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
5-4
OL-25178-02
Chapter 5
Troubleshooting
Pinouts
Table 5-6
Line 15
T1/E1 Interface Pinouts (continued)
100
TX_RING_P5
41
1
94
RX_RING_P5
41
4
50
TX_TIP_P5
16
2
44
RX_TIP_P5
16
5
Figure 5-1 shows the wiring schematic of the cable used to connect the T1/E1 interface module to the
rear of the patch panel.
Wiring Schematic of Cable between T1/E1 Interface and Patch Panel
343344
Figure 5-1
Management Ethernet Port Pinout
Table 5-7 summarizes the Management Ethernet port pinout.
Table 5-7
Fan Tray Alarm Port Pinout
Pin
Signal Name
1
TRP0+
2
TRP0-
3
TRP1+
4
TRP2+
5
TRP2-
6
TRP1-
7
TRP3+
8
TRP3-
Description
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
OL-25178-02
5-5
Chapter 5
Troubleshooting
Pinouts
USB Console Port Pinout
Table 5-8 summarizes the USB console port pinout.
Table 5-8
Single USB Console Port
Pin
Signal Name
Direction
Description
A1
Vcc
+5VDC (500mA)
A2
D-
Data -
A3
D+
Data +
A4
Gnd
Ground
5
Ground
6
Ground
7
Ground
8
Ground
Note
The USB Console port +5VDC is input and operates as an USB peripheral device.
USB Flash/MEM Port Pinout
Table 5-9 summarizes the USB flash/MEM port pinout.
Table 5-9
Single USB Flash/MEM Port
Pin
Signal Name
Direction
Description
A1
Vcc
+5VDC (500mA)
A2
D-
Data -
A3
D+
Data +
A4
Gnd
Ground
5
Ground
6
Ground
7
Ground
8
Ground
Note
USB TYPE-A receptacle used.
Note
The USB flash/MEM port +5VDC is output. We provide power for USB flash/MEM, and it
operates as a USB host device.
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
5-6
OL-25178-02
Chapter 5
Troubleshooting
LED Summary
Fiber-Optic Specifications
The specification for optical fiber transmission defines two types of fiber: single-mode and multimode.
Within the single-mode category, three transmission types are defined: short reach, intermediate reach,
and long reach. Within the multimode category, only short reach is available. For information about
optical SFP modules, see the documentation for the SFP module at
http://www.cisco.com/en/US/partner/products/hw/modules/ps5455/prod_installation_guides_list.html.
LED Summary
The following sections describe the meanings of the LEDs on the Cisco ASR 903 Series Router.
•
RSP LEDs, page 5-7
•
Interface Module LEDs, page 5-8
•
Power Supply LEDs, page 5-10
•
Fan Tray LEDs, page 5-10
RSP LEDs
Table 5-10 summarizes the RSP LEDs.
Note
A major alarm condition indicates the failure of a single fan in the fan tray; a critical alarm
indicates the failure of multiple fans. In the event that a single fan fails, the Cisco ASR 903
Series Router software adjusts the fan speed to prevent excessive heat within the chassis.
Table 5-10
RSP LEDs
LED
Color/State
Description (two LEDs for eachT1/E1 port)
Power
(PWR)
Off
Disabled/no power to RSP
Green
Power rails on RSP in range
Status
(STAT)
Off
Disabled/power down
Red
Failure to boot (lit at reset)
Yellow
Rommon booted
Green
IOS booted and running
Off
Not available
Yellow
Standby (indicates standby RSP)
Green
Active (indicates active RSP)
Active
(ACTV)
Management Off
port
(MGMT)
No connection
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
OL-25178-02
5-7
Chapter 5
Troubleshooting
LED Summary
Table 5-10
LED
RSP LEDs (continued)
Color/State
Description (two LEDs for eachT1/E1 port)
Green
Connected with no activity
Flashing
green
Connected with activity
Off
Not enabled
Yellow
Free run
Flashing
yellow
Holdover
Green
Locked to source
USB flash
(MEM)
Flashing
green
USB activity
BITS
Off
Out of service/not configured
Amber
Fault or loop condition
Green
In frame/working properly
Sync status
(SYNC)
Interface Module LEDs
Table 5-11 summarizes the interface module LEDs. This LED summary applies to the following
interface modules:
•
SFP Gigabit Ethernet Interface Module
•
RJ45 Gigabit Ethernet Interface Module
•
XFP 10 Gigabit Ethernet XFP Interface Module
Table 5-11
Interface Module LEDs
LED
Color/State
Description (two LEDs for eachT1/E1 port)
Power
(PWR)
Off
Disabled/no power to IM
Green
Enabled and power rails on IM in range
Status
(STAT)
Off
Disabled/power-down
Red
Failure (on at reset)
Amber
Booting (if local CPU)
Green
Operational
Off
Inactive or no connection
Amber
Fault/loop condition
Green
Ok with no activity
Flashing
green
OK with activity
Off
100/10 Mbps/Slow
Green
1Gbps/Full
Link status
(L)
Speed (S)
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
5-8
OL-25178-02
Chapter 5
Troubleshooting
LED Summary
OC-3 Interface Module LEDs
Table 5-13 summarizes the LEDs for the OC-3 interface module.
Table 5-12
Interface Module LEDs
LED
Color/State
Description (two LEDs for eachT1/E1 port)
Power
(PWR)
Off
Disabled/no power to IM
Green
Enabled and power rails on IM in range
Status
(STAT)
Off
Disabled/power-down
Red
Failure (on at reset)
Amber
Booting (if local CPU)
Green
Operational
Carrier/
Alarm(C/A)
Green
SFP receiving good remote signal
Yellow
Remote or local alarm activated
Active/
Loopback
(A/L)
Green
SFP ready and operating normally
Yellow
SFP port in loopback state
T1/E1 Interface Module LEDs
Table 5-13 summarizes the LEDs for the T1/E1 interface module.
Table 5-13
T1/E1 Interface Module LEDs
LED
Color/State
Description (two LEDs for eachT1/E1 port)
Active
Green
Active
Blinking
green
Standby
Off
Operationally down; card is disabled or shut down
Green
All ports up
Blinking
green
All ports up and one or more ports in a loopback state
Amber
One or more configured ports are down
Blinking
amber
One or more configured ports are down and at least one configured port
is in a loopback state
Off
All ports disabled or shut down
Port
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
OL-25178-02
5-9
Chapter 5
Troubleshooting
LED Summary
Power Supply LEDs
Table 5-14 summarizes the power supply LEDs.
Table 5-14
Power Supply LEDs
LED
Color/State
Description (two LEDs for eachT1/E1 port)
Input Power
(PWR)
Off
No input voltage
Amber
Input voltage out of range
Green
Input voltage within acceptable operating range
Off
Disabled/power-down/no power
Red
Power supply fault (internal failure)
Green
Operational
Status
(STAT)
Fan Tray LEDs
Table 5-15 summarizes the fan tray LEDs.
Table 5-15
Fan Tray LEDs
LED
Color/State
Description (two LEDs for eachT1/E1 port)
Status
(TEMP)
Off
Disabled/power down
Amber
Over temperature
Green
OK
Green
Fan rotation in range
Amber
Fan fault
Red
Two or more fan faults
Minor
(MIN)
Off
No minor alarm
Amber
Minor alarm
Major
(MAJ)
Off
No major alarm
Red
Major alarm (defaults to ON upon RSP reset)
Critical
(CRIT)
Off
No critical alarm
Red
Critical alarm (defaults to ON upon RSP reset)
Fan (FAN)
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
5-10
OL-25178-02
A P P E N D I X
A
Site Log
Use the Site Log to provide a record of actions related to installing and maintaining the router. Keep it
in an accessible place near the chassis so that those who performs tasks have access to it. Use the
Installation Checklist (see the “Site Planning” section on page 2-9) to verify the steps in the installation
and maintenance of your router. Site Log entries might include the following:
•
Installation progress—Make a copy of the Cisco ASR 903 Series Router Installation Checklist, and
insert it into the Site Log. Make entries as you complete each task.
•
Upgrade, removal, and maintenance procedures—Use the Site Log as a record of ongoing router
maintenance and expansion history. Each time a task is performed on the Cisco ASR 903 Series
Router, update the Site Log to reflect the following:
– Removal or replacement of interface modules, fan tray, power supplies, or RSPs
– Configuration changes
– Maintenance schedules and requirements
– Maintenance procedures performed
– Intermittent problems
– Comments and notes
Table A-1 on page A-2 shows a sample site log. Make copies of the sample or design your own site log
to meet the needs of your site and equipment.
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
OL-25178-02
A-1
Appendix A
Table A-1
Date
Site Log
Site Log
Description of Action Performed or Symptom Observed
Initials
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
A-2
OL-25178-02
I N D EX
electromagnetic pulse
A
See EMP
airflow
EMP, avoiding
chassis clearance
altitude
2-13
2-16
2-10
G
auxiliary port
connecting to a modem
3-30 to ??
B
global parameters, configuring
4-7
H
back panel
3-7
humidity
C
2-10
I
cable length, factors determining
2-13
installation
chassis
starting the router
ground connection description
preventing overheating
coaxial cable
2-12
installing
2-16
2-12
4-2
lifting chassis
2-19
interface
commands
numbering
show environment
2-16
show running-config
show startup-config
1-14
Interface Numbering
4-8
IP, router address
1-14
4-6
4-8
configuring
global parameters
reviewing changes
L
4-7
4-8
log
connecting
site
router to a PC
console port
A-1
?? to 3-24
4-6
M
modifications to configuration, reviewing
E
electrical wiring requirements
4-8
2-11
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
OL-25178-02
IN-1
Index
startup system
N
4-2
numbering
interface
T
1-14
temperature sensor
1-13
terminal server connections
P
4-6
PC
connecting to router
?? to 3-24
power
surge suppression
power lines (warning)
2-13
2-4
power supplies (warning)
2-4
procedures
starting the router
4-2
R
regulatory compliance
1-15
restricted access (warning)
2-4
reviewing changes to configuration
RJ-45 connectors
4-8
2-13
router
connecting to a PC
?? to 3-24
RS-232 asynchronous data
2-13
S
safety
information
1-15
sample configurations, global parameters
4-7
show commands
show running-config
show startup-config
4-8
4-8
show environment command
2-16
site
log
A-1
site requirements, rack-mounting
2-15
Cisco ASR 903 Series Aggregation Services Router Hardware Installation Guide
IN-2
OL-25178-02
Download PDF
Similar pages