IP 20/NEMA 1 & IP 66/NEMA 4X
Compact Vector Control Drive
APPLICATIONS
General multi-function model IP 20/NEMA 1
Textiles
Woodworking
Small Handling Machine
Simple Metal Processing
Machine Tools
Packaging & Labeling
Food Processing
Fan & Pumps
HVAC
Tough enclosure model IP 66/NEMA 4X
Food processing : against washdown
environment
Textiles : against high heat and
humid environment, like dyeing
process
Petrochemical industry : against
corrosive environment
Livestock industry : against
washdown environment
Woodworking manufacturing :
against dusty environment
Sealed Design
High level of waterproof
and dustproof
Model Identification
E510
E510 series
2
P5
H
1
F
N4S
Input Voltage
Horse Power
Type
Power Supply
Noise Filter
Appearance
P5: 0.5 HP
08: 7.5 HP
01: 1 HP
10: 10 HP
02: 2 HP
15: 15 HP
03: 3 HP
20: 20 HP
05: 5 HP
25: 25 HP
2: 200V class
4: 400V class
1: Single-phase
H:
3: Three-phase
Standard
Blank: Single-/
Three-phase
N4S: IP66,built-in
power switch and VR
Blank: None N4: IP66,without built-in
power switch or VR
F: Built-in
N4R: IP66,built-in VR,
without power switch
Blank: IP20
Capacity Range
Power Rating
0.4kW
0.5HP
0.75kW
1HP
1.5kW
2HP
2.2kW
3HP
3.7kW
5HP
5.5kW
7.5HP
7.5kW
10HP
11kW
15HP
15kW
20HP
18.5kW
25HP
200V 1-phase (with filter)
200V 1-/ 3-phase
E510
200V 3-phase
400V 3-phase
Features and Benefits
Features
32 bit RISC Processor with an advanced
IGBT power switching technology
Capability
H/W
Function
S/W
Function
Output frequency range is 0-650Hz
Power range:
200V 0.4~15kW (0.5HP~20HP)
400V 0.75~18.5kW (1HP~25HP)
Advanced sensorless vector control, providing a powerful starting torque at low
frequency with high performance operation at the highest efficiency.
The latest generation of IGBT power module
New generation of IPM/ PIM power module can reach higher efficiency of switching
and compact design of inverters.
With 7-segment *5 display panel
From this information, users can be easy to understand the usage state of inverters.
Standard built-in VR knob
Directly frequency setting and simple to adjust speed
Built-in EMC filter in compliance with IEC/ EN
61800-3 & 61800-5-1
Lower electromagnetic interference effectively
Fan control (set by parameter)
Fan control is based on the ambient temperature of key components to lower noise
and avoid unnecessary energy wasted.
Soft-PWM modulation
Reduce audible motor noise at low carrier frequency
Integrated safety stop and fire mode functions
Provide advanced application functions under the circumstance of emergency or fire.
Auto carrier frequency switching
Built-in sensors detection on operation temperature to avoid the probability of inverter
tripping in too high temperature.
Built-in PID controller
Provide constant control requirements of frequency, pressure, flow, air volume in
applications, such as HVAC
Built-in PLC function
Simple process control to save the cost of external PLC
Built-in Modbus Communication (RS485)
Expansion
Flexibility PC-software/ Copy unit
Quality
Benefit
External cooling heatsink
Fast parameters copying to reduce time of installation, maintenance and replacement.
Reduce the possibility of unknown objects entering to avoid damaging components
and improve product reliability.
2
Wiring Diagram
Single-phase/ Three-phase
Single-phase power input
Molded-case circuit
breaker
Magnetic
contactor
MC
MCCB
L1 (L)
(
AC
Power
source
Braking resistor
( Option )
(
L3 (N)
Magnetic
contactor
Molded-case
circuit breaker
P
Three-phase power input
MC
Inverter
output
L2
(
*1
L1 (L)
(
AC
Power
source
T1
(
MCCB
BR
L3 (N)
M
T2
Induction
Motor
T3
Ground
Multifunction Input Terminals
CON 2
FWD (Run/Stop)
S1
REV (Run/Stop)
S2
Pin 1 to Pin 8
S3
Speed Control
R1A
S4
S5
Reset
Relay
Output
S6
COM (NPN)
Common point for PNP input
+24V (PNP)
E
+
External speed potentiometer
=10 kohm or PID input
0/2~10V ,0/4~20mA
0/2~10V ,0/4~20mA
R1C
250 VAC/1A
(30VDC/1A)
R2A
Relay
Output
P
NPN AI1 AI2
J
J
J
P
P
P
3
1
2
SG
10V
AI1
PNP AV1 AV2
AI2
P
-
Shield wires
R1B
R2B
250 VAC/1A
(30VDC/1A)
SF
Output disable
P
1: Data+
2: Data3: Data+
4: RXD0
RS485 5: TXD0
6: Data7: 5V
8: GND
AGND
AO
+
AO
AGND
E
Shielded twisted-pair wires
*1: Power input terminal is L1, L2, L3 in models of 200V 7.5HP~20HP/ 400V 7.5HP~25HP.
-
Frequency
Indicator
0~10VDC
General Specifications
Item
Control Mode
E510
V/F Control, Vector Control
Output Frequency
0.01~599.00Hz
Starting Torque
150%/3Hz(V/F), 150%/1Hz(Vector)
Speed Control Ratio
1:50
Setting Resolution
Frequency
Digital input: 0.01Hz
Analog input:0.06Hz/60Hz
Keypad: Set directly with▲▼ keys or the VR on the keypad
Setting
External Input Terminlas:
AI1/AI2(0/2~10V,0/4-20mA)
Multifunction input up/down function(Group3)
Setting frequency by communication method.
Frequency Limit
Lower and upper frequency limits
3 jump frequency settings.
Keypad run, stop button
External terminals:
Run
Operation Set
Multi-function operation mode (2 or 3 wire selection)
Jog operation
Run signal by communication method.
Main Control
Features
V/F Curve Setting
18 fixed curves and one customized curve
Carrier Frequency
1∼16KHz
Acceleration and
2 sections of acceleration/ deceleration time setting (0.1~3600.0 Sec.)
Multifunction Input
29 functions (refer to group 3 in the manual)
Multifunction Output
21 functions (refer to group 3 in the manual)
Multifunction Analog Output
5 functions (refer to group 4 in the manual)
Deceleration Control
Main Features
4 sections of S curve setting
Overload Detection,16 preset speeds, Auto-run, Acc/Dec Switch, Main/Alt Run
Command Select, Main/Alt Frequency Command Select ,PID control, Torque
Compensation, V/F Start Frequency, Slip Compensation, Fault Reset.
LED
Display
Display: parameter / parameter value / frequency / line speed / DC voltage / output
voltage / output current / PID feedback / input and output terminal status / Heat sink
temperature / Program version / Fault Log.
Protective
Functions
LED Status Indicator
Run / Stop / Forward / Reverse ,and etc.
Overload Protection
The relays to protect the motor and the inverter. (150%/1min)
Over Voltage
200V class: >410V , 400V class: >820V
Under Voltage
200V class: <190V , 400V class: <380V
Momentary Power Loss Restart
Inverter auto-restart after a momentary power loss.
Stall Prevention
Stall prevention for Acceleration/ Deceleration/ Operation.
Short-circuit Output Terminal
Electronic Circuit Protection
Grounding Fault
Electronic Circuit Protection
Protection for overheating of heat sink, the carrier frequency decreasing with the
Other Protection Functions
temperature function, fault output, reverse prohibit, prohibit for direct start after
power up and error recovery ,parameter lock up
All frames include brake transistor
Communication control
Standard built-in RS485 communication (Modbus), One to one or One to many control.
IP 20 / NEMA 1 : -10~50℃ (without dustproof paster)
-10~40℃ (with dustproof paster)
Operating temperature
IP 66 / NEMA 4X : -10~50℃
Environment
Storage temperature
-20~60℃
Humidity
95% RH or less (no condensation)(Compliance with IEC 60068 - 2-78)
Shock
1.0G, in compliance with IEC 60068-2-6
Enclosure
IP 20 / NEMA 1 and IP 66 / NEMA 4X
4
IP 20/NEMA 1
Basic Specifications
Model
2P5
0.5
0.4
3.1
1.2
Horse Power (HP)
Suitable Motor Capacity (KW)
Rated Output Current (A)
Rated Capacity (KVA)
Input Voltage Range(V)
Allowable Voltage Fluctuation
Output Voltage Range(V)
Input Current (A)
Allowable Momentary Power Loss Time (Sec.)
Enclosure
Frame Size
8.5
2P5
0.5
0.4
3.1
1.2
Horse Power (HP)
Suitable Motor Capacity (KW)
Rated Output Current (A)
Rated Capacity (KVA)
Input Voltage Range(V)
Allowable Voltage Fluctuation
Output Voltage Range(V)
Input Current (A)
Allowable Momentary Power Loss Time (Sec.)
Enclosure
Frame Size
Horse Power (HP)
Suitable Motor Capacity (KW)
Rated Output Current (A)
Rated Capacity (KVA)
Input Voltage Range(V)
Allowable Voltage Fluctuation
Output Voltage Range(V)
Input Current (A)
Allowable Momentary Power Loss Time (Sec.)
Enclosure
Frame Size
Model
Horse Power (HP)
Suitable Motor Capacity (KW)
Rated Output Current (A)
Rated Capacity (KVA)
Input Voltage Range(V)
Allowable Voltage Fluctuation
Output Voltage Range(V)
Input Current (A)
Allowable Momentary Power Loss Time (Sec.)
Enclosure
Frame Size
8.5/4.5
2.0
205
5
3.7
17.5
6.7
11
2.0
20.5
2.0
1
2
401
1
0.75
2.3
1.7
4.2
402
2
1.5
3.8
2.9
2.0
1
5.6
2
IP 20/NEMA 1
203
3
2.2
10.5
4.0
2.0
23.9/12.5
2
200V Class: Three-phase
E510-���- H3
210
208
10
7.5
7.5
5.5
35
26
13.3
9.9
Three-phase 200~240V, 50/60HZ
-15%~+10%
Three-phase 0~240V
42
33
2.0
IP 20/NEMA 1
3
400V Class: Three-phase
E510-���- H3 (F)
403
405
408
410
3
5
7.5
10
2.2
3.7
5.5
7.5
5.2
8.8
13.0
17.5
4.0
6.7
9.9
13.3
Three-phase 380~480V, 50/60HZ
-15%~+10%
Three-phase 0~480V
7.3
11.6
17
23
2.0
2.0
IP 20/NEMA 1
2
23.9
2.0
200V Class: Single-/Three-phase
E510-���- H
202
201
2
1
1.5
0.75
7.5
4.5
2.9
1.7
Single-/Three-phase 200~240V, 50/60HZ
-15%~+10%
Three-phase 0~240V
16/11
12/6.5
1
202
2
1.5
7.5
2.9
203
3
2.2
10.5
4.0
IP 20/NEMA 1
1
Model
Model
2.0
200V Class: Single-phase
E510-���- H1F
202
201
2
1
1.5
0.75
7.5
4.5
2.9
1.7
Single-phase 200~240V, 50/60HZ
-15%~+10%
Three-phase 0~240V
16
12
3
220
20
15
64
27.4
215
15
11
48
20.6
57
70
2.0
4
415
15
11
24
19.1
420
20
15
32
24
31
38
425
25
18.5
40
30.5
2.0
4
48
I P 6 6 / N E MA 4X
Model
200V Class: Single-phase
E510-���- H1F(N4)(S)
201
202
1
2
0.75
1.5
4.5
7.5
1.7
2.9
2P5
0.5
0.4
3.1
1.2
Horse Power (HP)
Suitable Motor Capacity (KW)
Rated Output Current (A)
Rated Capacity (KVA)
Input Voltage Range(V)
Allowable Voltage Fluctuation
Output Voltage Range(V)
Input Current (A)
Allowable Momentary Power Loss Time (Sec.)
Enclosure
Frame Size
Single-phase 200~240V, 50/60HZ
-15%~+10%
8.5
2.0
8.5/4.5
Horse Power (HP)
Suitable Motor Capacity (KW)
Rated Output Current (A)
Rated Capacity (KVA)
Input Voltage Range(V)
Allowable Voltage Fluctuation
Output Voltage Range(V)
Input Current (A)
Allowable Momentary Power Loss Time (Sec.)
Enclosure
Frame Size
2.0
20.5
2.0
33
402
2
1.5
3.8
2.9
1
203
3
2.2
10.5
4.0
23.9/12.5
2.0
2
200V Class: Three-phase
E510-���- H3(N4)
210
215
10
15
7.5
11
35
48
13.3
20.6
Three-phase 200~240V, 50/60HZ
-15%~+10%
Three-phase 0~240V
42
57
2.0
IP 66 / NEMA 4X
220
20
15
64
27.4
70
2.0
3
Model
2.0
2
IP 66 / NEMA 4X
208
7.5
5.5
26
9.9
2
4.2
23.9
2.0
Three-phase 0~240V
12/6.5
16/11
205
5
3.7
17.5
6.7
401
1
0.75
2.3
1.7
16
IP 66 / NEMA 4X
1
Model
Three-phase 0~240V
200V Class: Single-/Three-phase
E510-���- H(N4R)
201
202
1
2
0.75
1.5
4.5
7.5
1.7
2.9
Single-/Three-phase 200~240V, 50/60HZ
-15%~+10%
2P5
0.5
0.4
3.1
1.2
Horse Power (HP)
Suitable Motor Capacity (KW)
Rated Output Current (A)
Rated Capacity (KVA)
Input Voltage Range(V)
Allowable Voltage Fluctuation
Output Voltage Range(V)
Input Current (A)
Allowable Momentary Power Loss Time (Sec.)
Enclosure
Frame Size
Horse Power (HP)
Suitable Motor Capacity (KW)
Rated Output Current (A)
Rated Capacity (KVA)
Input Voltage Range(V)
Allowable Voltage Fluctuation
Output Voltage Range(V)
Input Current (A)
Allowable Momentary Power Loss Time (Sec.)
Enclosure
Frame Size
12
1
Model
203
3
2.2
10.5
4.0
5.6
400V Class: Three-phase
E510-���- H3 (F)(N4)(S)
*N4S 400V class to 15HP only
403
405
408
410
3
5
7.5
10
2.2
3.7
5.5
7.5
5.2
8.8
13.0
17.5
4.0
6.7
9.9
13.3
Three-phase 380~480V, 50/60HZ
-15%~+10%
Three-phase 0∼480V
7.3
11.6
17
23
2.0
2.0
IP 66 / NEMA 4X
2
415
15
11
24
19.1
420
20
15
32
24
31
38
425
25
18.5
40
30.5
2.0
48
3
6
IP 20 / NEMA 1 (without filter series)
Dimensions
Unit: mm (inch)
W
W1
W2
H
H1
H2
D
D1
Frame 4
90.6
(3.57)
128.7
(5.07)
186.9
(7.36)
224.6
(8.84)
80.5
(3.17)
118
(4.65)
175
(6.89)
207
(8.15)
80.5
(3.17)
118
(4.65)
176
(6.92)
207
(8.15)
163.6
(6.44)
187.6
(7.39)
260.9
(10.27)
321.6
(12.66)
153
(6.02)
177.6
(6.99)
249.8
(9.83)
303.5
(11.95)
173.5
(6.84)
197.5
(7.78)
273
(10.75)
330.9
(13.03)
149
(5.87)
150
(5.91)
197.2
(7.76)
200.7
(7.9)
137.8
(5.43)
133.8
(5.27)
184
(7.24)
187.5
(7.38)
Frame 1
(weight:1.7Kg)
Frame 2
Frame 3
Frame 2
2-Q1
E
Q1
Q2
-
48
(1.89)
48.2
(1.9)
76.7
(3.02)
94
(3.7)
4.3
(0.17)
4.5
(0.18)
4.5
(0.18)
6
(0.24)
4.3
(0.17)
4.5
(0.18)
4.5
(0.18)
6
(0.24)
141.8
(5.58)
189
(7.44)
192.5
(7.58)
D1
D3
(weight:2.5Kg)
W1
H
H2
H1
W1
D2
2-Q1
H2
Frame 1
H
H1
Frame
D2
2-Q2
W2
W
E
E
D1
D
2-Q1
D1
D
D1
D2
W2
W
H2
H
E
2-Q1
H1
H2
W1
W2
W
D2
2
2-Q
W2
W
(weight:10.5Kg)
2-Q2
D1
D
2-Q1
H1
H
W1
D2
Frame 4
(weight:6.5Kg)
D1
D
Frame 3
E
IP 66 / NEMA 4X
Unit: mm (inch)
W
W1
H
150.8
(5.94)
198
(7.80)
222.8
(8.77)
133.3
(5.25)
115
(4.53)
140
(5.51)
248.7
(9.79)
337.9
(3.30)
466.3
(18.36)
Frame
Frame 1
W
W1
Frame 2
Frame 3
H1
230.2
(9.06)
335
(13.19)
460
(18.11)Q1
H2
214.2
(8.43)
315
(12.40)
440
(17.32)
D
183
(7.20)
218.4
(8.60)
W
246.6
W1
(9.71)
D1
D2
D3
Q1
Q2
Q3
200
(7.87)
235.2
(9.26)
266.5
(10.49)
200
(7.87)
235.2
(9.26)
263.5
(10.37)
49.5
(1.95)
79.8
(3.14)
96
(3.78)
5.4
(0.21)
7
(0.28)
7
(0.28)
5.4
(0.21)
7
(0.28)
7
(0.28)
10.6
(0.42)
5.98
(0.24)
12.68
(0.50)
*N4R model has no built-in power switch, so D1 is not applicable.
N4 model has no built-in power switch and VR, so D1 and D2 are not applicable.
Frame 2
Q1
W1
H2
D1
(weight:5.98Kg)
W
W1
H
H2
H1
H
(weight:2.9Kg)
W
H1
Frame 1
D2
H
H1
H2
H
H2
H1
D3
Q2
D2
D3
D3
D
D2
D
D1
D2
D
D3
D3
D
D2
W
W1
D1
Q1
D1
Q2
H
H1
H2
H
W
W1
H2
Q1
(weight:12.68Kg)
H1
Frame 3
Q2
D
D3
D3
D2
D2
D1
D
D1
Q2
8
Accessories
Accessories
Keypad
extension
cable
Model
Notes
JN5-CB-01M
JN5-CB-02M
JN5-CB-03M
1m
Keypad extension cable for 510 series
JN5-CB-05M
JN5-NK-E01
NEMA Kits
Function
JN5-NK-E02
JN5-NK-E03
JN5-NK-E04
2m
3m
5m
Mechanical device consisting of anti-dust cover
on the upper part and wiring box on the bottom
to meet NEMA 1
Only for frame 1
Only for frame 2
Only for frame 3
Only for frame 4
① Duplicating parameters setting in one
Copy module
JN5-CU
inverter to another inverter
② As a remote keypad to be used
③ Using RJ45 line to connect inverter
JN5-CM-PDP
JN5-CM-TCPIP
For connection of Profibus-DP communication
protocol
For connection of TCP-IP communication
protocol
Communication
modules
For 510 series
JN5-CM-DNET
JN5-CM-CAN
RJ45 to USB
connection
cable
JN5-CM-USB
For connection of DeviceNet communication
protocol
For connection of CANopen communication
protocol
Using the TECO exclusive PC-software line
Copy Unit (JN5-CU)
1.8m
RJ45 to USB (JN5-CM-USB)
MEMO
10
10F, No. 3-1, Park St., Nan-Kang, Taipei 115, Taiwan
TEL : 886-2-6615-9111Ext.1725
FAX : 886-2-6615-1033
http://globalsa.teco.com.tw
Specifications covered in this brochure may be subject to change without notice.
GJ-62-10 2016-06-01
Download PDF