Price List 2017 - Cool Designs Ltd

Price List 2017
Contents
MAMBO - Universal air conditioner.......................................................................................................................................................... 6
MAMBO - Console air conditioner............................................................................................................................................................ 8
STELLA - High-wall air conditioner............................................................................................................................................................. 9
SALSA - Cassette air conditioner.............................................................................................................................................................. 10
TWIST - Ducted air conditioner............................................................................................................................................................... 12
Multi-split system - Outdoor units.......................................................................................................................................................... 14
Multi-split system - Indoor units............................................................................................................................................................. 15
Multi-split system - possible system combinations................................................................................................................................. 16
EREBA - Reversible heat pump................................................................................................................................................................ 17
EREBA performance tables...................................................................................................................................................................... 18
GEOCIAT Power - Water-to-water heat pump......................................................................................................................................... 21
GEOCIAT Power performance tables....................................................................................................................................................... 22
GEOCIAT Access - Geothermal heat pump.............................................................................................................................................. 23
GEOCIAT Access accessories.................................................................................................................................................................... 24
GEOCIAT Access performance tables....................................................................................................................................................... 24
AQUACIAT Caleo - Air-to-water heat pump............................................................................................................................................. 25
AQUACIAT Caleo performance tables...................................................................................................................................................... 26
AQUACIAT - Air-cooled liquid chillers...................................................................................................................................................... 27
AQUACIAT cooling only accessories........................................................................................................................................................ 28
AQUACIAT liquid chiller performance table............................................................................................................................................. 29
AQUACIAT - Air-cooled heat pumps........................................................................................................................................................ 30
AQUACIAT heat pump accessories.......................................................................................................................................................... 31
AQUACIAT heat pump performance tables............................................................................................................................................. 32
COADIS LINE 600 - Cassette fan coil unit................................................................................................................................................. 36
COADIS LINE 900 - Cassette fan coil unit................................................................................................................................................. 37
COMFORT LINE - Ducted type fan coil..................................................................................................................................................... 38
COMFORT LINE available options............................................................................................................................................................ 39
MAJOR LINE CV/CH - Cabinet unit........................................................................................................................................................... 40
MAJOR LINE NCV/NCH - Concealed unit................................................................................................................................................. 41
MAJOR LINE - Cabinet and concealed unit options................................................................................................................................. 42
FLOWAY ACCESS - Air handling unit......................................................................................................................................................... 43
FLOWAY ACCESS - Air handling unit accessories...................................................................................................................................... 44
FLOWAY CLASSIC - Air handling unit with rotary heat exchanger............................................................................................................ 45
FLOWAY CLASSIC air handling unit with rotary heat exchanger accessories........................................................................................... 46
FLOWAY CLASSIC - Air handling unit with plate heat exchanger............................................................................................................. 47
FLOWAY CLASSIC air handling unit with plate heat exchanger accessories............................................................................................. 48
FLOWAY VERTICAL - Air handling unit..................................................................................................................................................... 49
FLOWAY CEILING - Air handling unit........................................................................................................................................................ 50
HELIOTHERME 4000 - Air heater/chiller.................................................................................................................................................. 51
SPACE - Packaged unit............................................................................................................................................................................. 52
SPACE packaged unit options and accessories........................................................................................................................................ 53
Air product range of equipment.............................................................................................................................................................. 54
Chiller and heat pump range of equipment............................................................................................................................................ 55
Toshiba range of products and services.................................................................................................................................................. 57
This document is not binding. As part of its policy for continual product improvement, CIAT reserves the right to make any product improvements without prior notification.
All reproduction rights reserved. None of the content in this document may be reproduced, transmitted, sold, commercially exploited, or reused in any manner.
2
A leader in Cooling, Heating and Indoor Air Quality
CIAT GROUP is a leading European manufacturer of a wide range of climate control products. Founded in 1934 we now
supply to over 50 countries worldwide. Following integration into United Technologies Corporation, CIAT UK operates
alongside Toshiba Air Conditioning.
Together our vision is to be the UK’s No. 1 supplier of technologically innovative, energy-efficient, environmentally-friendly
HVAC equipment, combined with a first class level of customer support.
•
•
•
•
•
•
Cutting-edge technology backed by a significant R&D programme.
Industrial excellence utilising the latest manufacturing processes.
Partnership programme to achieve excellence within our field.
Huge investment in the AHU production Airside Excellence Centre.
One of the largest HVAC innovation centres in Europe.
Product performance levels are validated by experts in our own test rooms.
We offer our customers full support from our engineers to back our supply of exceptional products. From design and
specification, through installation and commissioning, control integration and maintenance we work with you to form a
real partnership.
3
A leader in Cooling, Heating and Indoor Air Quality
CIAT Centre of Excellence
The new CIAT Centre of Excellence includes two research and development facilities and test laboratories, which focus on
product innovation to shorten new product development time scales and improve energy performance and user comfort.
The R&D investment is part of more than $40m that UTC has invested at Culoz and Montluel, since the acquisition in 2015.
The factory in Montluel houses a Centre of Excellence for chillers and heat pumps. It supports chiller innovation and
production, with a focus on new generation, environmentally-responsible refrigerants, with Culoz supporting further
development of the new AHU range introduced during 2016.
The strategic move allows us to strengthen our heating, ventilating and air conditioning range, as well as our competitiveness
and ability to innovate. The significant investment in the Culoz and Montluel sites complement each other and support
production and design, allowing further improvement of our products and our ability to serve our customers.
Sustainability at the heart of what we do
Both Centre of Excellence sites recently underwent industrial
transformations to support the company’s focus on
sustainable innovation.
“The environmental impact was an important consideration
of the site transformation, as we no longer use fossil energy
thanks to a biomass-boiler heating system with advanced
filters. The site also reduced water consumption by 40% while
achieving a waste recycling rate of 75%.”
4
A leader in Cooling, Heating and Indoor Air Quality
www.cdlweb.info
email: sales@cooldesignsltd.co.uk
tel.: 0191 549 6964
Inverter single- and multi-split units
Many possible applications
With the split-system range of units, it’s possible
to connect up to 5 indoor units to one single
outdoor unit. Different indoor units can be
connect to meet any requirement: high-wall
units, console units, cassette units or ducted
units. The multi-split range offers an ideal and
totally flexible solution.
Controlled comfort in each room
The split-system range is the ideal solution for residential
and commercial applications where it is necessary to
have total control of the indoor temperature. This new
range of air conditioners offers a large operating range
from -15°C to 46°C for improved comfort both in summer
and winter. The large choice of indoor units ensures the
best solution is available for each outdoor unit.
5
A leader in Cooling, Heating and Indoor Air Quality
www.cdlweb.info
email: sales@cooldesignsltd.co.uk
tel.: 0191 549 6964
MAMBO
Universal air conditioner
Inverter - R410A
Model
Indoor unit
Outdoor unit
Cooling capacity
Heating capacity*
P design capacity cooling
P design capacity heating
Temperature range
SEER
SCOP
Energy label
Min./nom./max.
Min./nom./max.
@ -7°C
@ -10°C
@ -15°C
Warmer/average
Cooling
Heating
Warmer/average
SEER
SCOP warmer/average
kW
kW
kW
kW
kW
kW
kW
°C
°C
W/W
W/W
Yearly energy consumption
kWh
EER/COP
W/W
Rated current
A
Rated input
kW
Power supply
V/ph/Hz
Refrigerant amount
R410A
kg
Liquid side - gas side
inch
Standard piping length
Min./max. piping length
m
Max. height difference
m
Additional charge
g/m
Indoor unit
Sound power level**
dB(A)
Sound pressure level**
High/med./low
dB(A)
Air flow
High/med./low
m3/h
Weight
kg
Dimension
WxDxH
mm
Outdoor unit
Sound power level**
dB(A)
Sound pressure level**
dB(A)
Air flow
m3/h
Weight
kg
Dimension
WxDxH
mm
System retail price
* -7°C/-10°C/-15°C heating at free frequency
£
•
•
•
•
•
•
Infra-red controller as standard (wired available).
Full Wi-Fi compatibility.
Can be installed vertically or horizontally.
Fresh air connection.
Easy access from inside the grille.
3D air flow meaning air intake from bottom or rear.
MAMBO
Ceiling 18HV
42HU18VSC
38HU18VSC
2.00/5.00/5.50
2.00/5.50/6.00
4.00
4.00
3.00
5.00
4.00/5.00
-10~46
-15~24
5.9
4.1/5.3
A+
A+/A+++
298/1470/1466
2.8/4.0
11
2.53
220-240/1/50
1.70
1/4 - 1/2
3/30
20
15
42HU18VSC
58
45/42/39
900/790/670
27.0/32.0
1068 x 675 x 235
38HU18VSC
65
57
2100
38.0/40.6
800 x 333 x 555
1,013
MAMBO
Ceiling 24HV
42HU24VSC
38HU24VSC
2.50/7.03/8.00
2.50/7.30/8.50
5.30
5.50
4.90
7.03
5.20/7.80
-10~46
-15~24
5.8
4.0/4.8
A+
A+/A++
424/1820/2373
2.9/3.3
16
3.68
220-240/1/50
2.05
3/8 - 5/8
3/40
20
30
42HU24VSC
65
50/47/41
1150/1040/790
27.0/32.0
1068 x 675 x 235
38HU24VSC
69
61
2700
50/54.5
845 x 363 x 702
1,397
MAMBO
Ceiling 36HV
42HU36VSC
38HU36VSC
4.40/10.40/11.00
3.70/11.90/13.80
9.80
8.40
8.20
10.40
10.20/10.60
-10~46
-15~24
6.3
4.0/5.1
A++
A+/A+++
576/3561/2922
2.6/3.7
23
4.80
220-240/1/50
3.65
3/8 - 5/8
3/50
25
30
42HU36VSC
65
55/51/46
2000/1700/1350
38.0/44.0
1650 x 675 x 235
38HU36VSC
70
64
4150
70.5/76.1
946 x 410 x 810
MAMBO
Ceiling 36HVT
42HU36VSC
38HU36VTC
4.00/10.40/11.40
2.90/11.90/14.50
9.70
8.30
8.20
10.40
10.30/10.40
-10~46
-15~24
6.3
4.0/5.1
A++
A+/A+++
575/3599/2874
2.8/3.7
12
4.80
380-415/3/50
3.65
3/8 - 5/8
3/50
25
30
42HU36VTC
65
55/51/46
2000/1700/1350
38.0/44.0
1650 x 675 x 235
38HU36VTC
70
64
4150
85.3/91
946 x 410 x 811
Part Number
7511630
7511631
Price, £
73
364
2,218
2,385
** Sound data in cooling mode
Accessories
Description
Wired remote control for LC range - KJR-12- G2
Centralised wired remote control for LC range connectable up to 64 units - CCM-30
6
A leader in Cooling, Heating and Indoor Air Quality
www.cdlweb.info
email: sales@cooldesignsltd.co.uk
tel.: 0191 549 6964
MAMBO
Universal air conditioner
Inverter - R410A
Model
Indoor unit
Outdoor unit
Cooling capacity
Heating capacity*
P design capacity cooling
P design capacity heating
Temperature range
SEER
SCOP
Energy label
Min./nom./max.
Min./nom./max.
@ -7°C
@ -10°C
@ -15°C
Warmer/average
Cooling
Heating
Warmer/average
SEER
SCOP warmer/average
kW
kW
kW
kW
kW
kW
kW
°C
°C
W/W
W/W
Yearly energy consumption
kWh
EER/COP
W/W
Rated current
A
Rated input
kW
Power supply
V/ph/Hz
Refrigerant amount
R410A
kg
Liquid side - gas side
inch
Standard piping length
Min./max. piping length
m
Max. height difference
m
Additional charge
g/m
Indoor unit
Sound power level**
dB(A)
Sound pressure level**
High/med./low
dB(A)
Air flow
High/med./low
m3/h
Weight
kg
Dimension
WxDxH
mm
Outdoor unit
Sound power level**
dB(A)
Sound pressure level**
dB(A)
Air flow
m3/h
Weight
kg
Dimension
WxDxH
mm
System retail price
* -7°C/-10°C/-15°C heating at free frequency
£
MAMBO
Ceiling 48HV
42HU48VSC
38HU48VSC
4.80/13.60/14.00
5.40/15.50/16.00
11.30
10.80
9.40
13.60
10.60/11.90
-10~46
-15~24
5.9
4.0/5.3
A+
A+/A+++
810/3718/3167
2.4/2.9
26.5
6.10
220-240/1/50
4.00
3/8 - 5/8
3/50
25
30
42HU48VSC
69
55/51/46
2100/1700/1500
38.2/44.6
1650 x 675 x 235
38HU48VSC
75
64
6800
95.1/108.4
952 x 415 x 1333
2,631
MAMBO
Ceiling 48HVT
42HU48VSC
38HU48VTC
4.80/13.60/14.00
5.40/15.50/16.00
11.10
10.50
8.60
13.60
11.30/12.10
-10~46
-15~24
5.8
4.0/5.3
A+
A+/A+++
815/3954/3179
2.4/3.0
13
6.10
380-415/3/50
4.00
3/8 - 5/8
3/50
25
30
42HU48VTC
69
55/51/46
2100/1700/1500
38.2/44.6
1650 x 675 x 235
38HU48VTC
75
64
6800
108.1/121.2
952 x 415 x 1333
2,660
MAMBO
Ceiling 60HVT
42HU60VSC
38HU60VTC
5.40/15.50/16.00
4.30/17.50/18.50
11.50
11.10
9.90
15.50
11.80/11.60
-10~46
-15~24
5.8
4.1/5.1
A+
A+/A+++
938/4011/3173
2.5/3.1
14
7.50
380-415/3/50
4.30
3/8 - 5/8
3/50
25
30
42HU60VTC
73
56/51/47
2250/1900/1500
40.5/47
1650 x 675 x 235
38HU60VTC
77
64
7000
112.8/126
952 x 415 x 1333
2,728
** Sound data in cooling mode
All split-system unit ratings are based on the following conditions:
Cooling capacities: Indoor air temperature 27°C (DB)/19°C (WB) - Outdoor air temperature 35°C (DB)/24°C (WB)
Heating capacities: Indoor air temperature 20°C (DB)/15°C (WB) - Outdoor air temperature 7°C (DB)/6°C (WB)
7
A leader in Cooling, Heating and Indoor Air Quality
www.cdlweb.info
email: sales@cooldesignsltd.co.uk
tel.: 0191 549 6964
MAMBO
Console air conditioner
•
•
•
•
•
•
Inverter - R410A
Model
Indoor unit
Outdoor unit
Cooling capacity
Heating capacity*
P design capacity cooling
P design capacity heating
Temperature range
SEER
SCOP
Energy label
Min./nom./max.
Min./nom./max.
@ -7°C
@ -10°C
@ -15°C
Warmer/average
Cooling
Heating
Warmer/average
SEER
SCOP warmer/average
kW
kW
kW
kW
kW
kW
kW
°C
°C
W/W
W/W
Yearly energy consumption
kWh
EER/COP
W/W
Rated current
A
Rated input
kW
Power supply
V/ph/Hz
Refrigerant amount
R410A
kg
Liquid side - gas side
inch
Standard piping length
Min./max. piping length
m
Max. height difference
m
Additional charge
g/m
Indoor unit
Sound power level**
dB(A)
Sound pressure level**
High/med./low
dB(A)
Air flow
High/med./low
m3/h
Weight
kg
Dimension
WxDxH
mm
Outdoor unit
Sound power level**
dB(A)
Sound pressure level**
dB(A)
Air flow
m3/h
Weight
kg
Dimension
WxDxH
mm
System retail price
* -7°C/-10°C/-15°C heating at free frequency
£
Infra-red controller as standard (wired available).
Full Wi-Fi compatibility.
Optional ‘follow me’ function.
Compact design.
Optimised air distribution.
Stylish and lightweight.
MAMBO
Console 9HV
42HC09VSC
38HU09VSC
0.90/2.60/3.20
0.80/2.90/3.70
2.70
2.40
2.10
3.00
2.30/2.50
-10~46
-15~24
6.1
4.0/5.3
A++
A+/A+++
151/805/686
3.1/3.4
10
2.30
220-240/1/50
0.28
1/4 - 3/8
3/20
8
15
42HC09VSC
60
43/39/34
460/400/360
13.5/18.0
700 x 600 x 210
38HU09VSC
64
54
1900
26.0/29.0
770 x 300 x 555
755
MAMBO
Console 12HV
42HC12VSC
38HU12VSC
1.00/3.52/3.50
1.00/3.70/4.00
2.80
2.60
2.40
4.00
2.90/3.60
-10~46
-15~24
5.9
4.0/4.9
A+
A+/A++
207/1016/1072
3.0/3.5
10
2.30
220-240/1/50
1.05
1/4 - 3/8
3/25
10
15
42HC12VSC
60
45/43/38
530/480/360
15.0/19.5
700 x 600 x 210
38HU12VSC
65
56
2100
28.5/31.5
800 x 333 x 554
799
MAMBO
Console 18HV
42HC18VSC
38HU18VSC
2.00/4.40/4.60
2.00/5.40/5.50
3.30
3.30
2.20
4.00
3.00/4.10
-10~46
-15~24
6.1
4.0/5.3
A++
A+/A+++
252/1048/1124
2.7/2.8
11
2.53
220-240/1/50
1.70
1/4 - 1/2
3/30
20
15
42HC18VSC
60
46/44/42
530/470/430
15.0/19.5
700 x 600 x 210
38HU18VSC
65
57
2100
38.0/40.5
800 x 333 x 554
1,001
** Sound data in cooling mode
Accessories
Description
Wired remote control for LC range - KJR-12- G2
Centralised wired remote control for LC range connectable up to 64 units - CCM-30
Part Number
7511630
7511631
Price, £
73
364
8
A leader in Cooling, Heating and Indoor Air Quality
www.cdlweb.info
email: sales@cooldesignsltd.co.uk
tel.: 0191 549 6964
•
•
•
•
•
•
Infra-red controller as standard (wired available).
Full Wi-Fi compatibility.
Self-clean operation and built-in Ioniser.
Louvre position memory.
Drain port on both sides for easy installation.
Refrigerant leakage detection display.
Model
Indoor unit
Outdoor unit
Cooling capacity
Heating capacity*
P design capacity cooling
P design capacity heating
Temperature range
SEER
SCOP
Energy label
Min./nom./max.
Min./nom./max.
@ -7°C
@ -10°C
@ -15°C
Warmer/average
Cooling
Heating
Warmer/average
SEER
SCOP warmer/average
kW
kW
kW
kW
kW
kW
kW
°C
°C
W/W
W/W
Yearly energy consumption
kWh
EER/COP
W/W
Rated current
A
Rated input
kW
Power supply
V/ph/Hz
Refrigerant amount
R410A
kg
Liquid side - gas side
inch
Standard piping length
Min./max. piping length
m
Max. height difference
m
Additional charge
g/m
Indoor unit
Sound power level**
dB(A)
Sound pressure level**
High/med./low/silence
dB(A)
Air flow
High/med./low/silence
m3/h
Weight
kg
Dimension
WxDxH
mm
Outdoor unit
Sound power level**
dB(A)
Sound pressure level**
dB(A)
Air flow
m3/h
Weight
kg
Dimension
WxDxH
mm
System retail price
* -7°C/-10°C/-15°C heating at free frequency
Accessories
Description
Wired remote control for high-wall units - KJR-12- G1
Wi-Fi USB for hung wall range - WIFI USB
£
STELLA 9HV
42HV09VSC
38HV09VSC
0.50/2.70/3.50
0.60/2.90/4.00
2.70
2.50
2.20
2.70
2.70/2.40
-15~46
-15~24
7.4
5.4/4.0
A++
A+++/A+
128/700/840
3.38/3.73
10.0
2.20
220-240/1/50
0.72
1/4 - 3/8
3/25
10
15
42HV09VSC
53
38/34/30/21
460/380/280/190
8.0
730 x 192 x 291
38HV09VSC
63
54
1900
26.5
770 x 300 x 555
468
STELLA
High-wall air conditioner
Inverter - R410A
STELLA 12HV
42HV12VSC
38HV12VSC
0.50/3.52/4.00
0.60/3.90/4.50
3.20
3.10
2.70
4.00
4.00/3.00
-15~46
-15~24
7.0
5.2/4.0
A++
A+++/A+
176/942/1015
3.12/3.51
10.0
2.20
220-240/1/50
0.75
1/4 - 3/8
3/25
10
15
42HV12VSC
54
40/35/31/22
500/390/300/200
9.0
812 x 192 x 300
38HV12VSC
64
55
2100
28.5
800 x 333 x 554
524
STELLA 18HV
42HV18VSC
38HV18VSC
0.80/5.28/6.00
1.00/5.50/6.30
4.10
3.90
3.70
5.00
6.00/4.00
-15~46
-15~24
7.1
5.2/4.0
A++
A+++/A+
260/1508/1505
3.25/3.20
12.5
2.75
220-240/1/50
1.70
1/4 - 1/2
3/30
20
15
42HV18VSC
57
42/37/35/24
760/550/460/260
11.5
973 x 218 x 319
38HV18VSC
65
55
2100
38.0
800 x 333 x 554
STELLA 24HV
42HV22VSC
38HV24VSC
1.40/6.40/6.70
1.50/7.00/7.30
4.50
4.40
4.20
6.00
7.00/5.00
-15~46
-15~24
7.1
4.8/4.0
A++
A++/A+
315/1954/1820
3.11/3.30
18.0
4.10
220-240/1/50
2.00
3/8 - 5/8
3/40
20
30
42HV22VSC
63
47/42/38/26
1150/890/770/420
13.5
1082 x 225 x 338
38HV24VSC
69
58
2700
44.0
845 x 363 x 702
Part Number
7511629
7511628
Price, £
68
17
730
944
** Sound data in cooling mode
9
A leader in Cooling, Heating and Indoor Air Quality
www.cdlweb.info
email: sales@cooldesignsltd.co.uk
tel.: 0191 549 6964
SALSA
Cassette air conditioner
•
•
•
•
•
•
Inverter - R410A
Model
Indoor unit
Indoor unit panel
Outdoor unit
Cooling capacity
Heating capacity*
Infra-red controller as standard (wired available).
Louvre position memory.
Drain pump up to 750 mm.
Full Wi-Fi compatibility.
360° air distribution.
Fresh air intake and fan compatible.
SALSA 9HV
42HK09VSC
40CAS-C6
38HU09VSC
Min./nom./max.
kW
0.90/2.64/3.70
Min./nom./max.
kW
0.80/3.00/3.80
@ -7°C
kW
3.00
@ -10°C
kW
3.00
@ -15°C
kW
2.00
P design capacity cooling
kW
2.64
P design capacity heating Warmer/average
kW
2.40/2.60
Temperature range
Cooling
°C
-10~46
Heating
°C
-15~24
SEER
W/W
6.2
SCOP
Warmer/average
W/W
4.0/5.1
Energy label
SEER
A++
SCOP warmer/average
A++/A+++
Yearly energy consumption
kWh
149/837/714
EER/COP
W/W
3.5/3.7
Rated current
A
10
Rated input
kW
2.30
Power supply
V/ph/Hz 220-240/1/50
Refrigerant amount
R410A
kg
0.72
Liquid side - gas side
inch
1/4 - 3/8
Standard piping length
Min./max. piping length
m
3/25
Max. height difference
m
10
Additional charge
g/m
15
Indoor unit
42HK09VSC
Sound power level**
dB(A)
58
Sound pressure level**
High/med./low
dB(A)
42/39/36
Air flow
High/med./low
m 3/h
560/430/390
Weight
Body
kg
15.0/18.0
Panel
kg
2.5/4.5
Dimension
Body W x D x H
mm
570 x 570 x 260
Panel W x D x H
mm
647 x 647 x 50
Outdoor unit
38HU09VSC
Sound power level**
dB(A)
64
Sound pressure level**
dB(A)
54
Air flow
m3/h
1900
Weight
kg
26.0/29.0
Dimension
WxDxH
mm
770 x 300 x 555
System retail price
* -7°C/-10°C/-15°C heating at free frequency
£
797
SALSA 12HV
42HK12VSC
40CAS-C6
38HU12VSC
1.40/3.52/3.90
1.20/4.00/4.20
2.70
2.70
2.40
3.52
2.94/3.50
-10~46
-15~24
6.2
4.1/5.1
A++
A+/A+++
199/1002/960
3.1/3.6
10
2.30
220-240/1/50
1.05
1/4 - 3/8
3/25
10
15
42HK12VSC
59
42/39/36
560/430/391
16.5/19.0
2.5/4.5
570 x 570 x 260
647 x 647 x 50
38HU12VSC
65
56
2100
28.5/31.5
800 x 333 x 554
831
SALSA 18HV
42KH18VSC
40CAS-C6
38HU18VSC
2.00/5.00/5.50
2.00/5.50/6.00
3.90
3.90
2.20
5.00
3.90/4.90
-10~46
-15~24
6.0
4.0/5.1
A+
A+/A+++
293/1365/1345
2.8/3.1
11
2.53
220-240/1/50
1.70
1/4 - 1/2
3/30
20
15
42HK18VSC
60
45/42/36
650/530/370
16.5/19.0
2.5/4.5
570 x 570 x 260
647 x 647 x 50
38HU18VSC
65
57
2100
38.0/40.5
800 x 333 x 554
1,108
SALSA 24HV
SALSA 36HV
42HK24VSC
42HK36VSC
40CAS-L9
40CAS-L9
38HU24VSC
38HU36VSC
2.50/7.03/8.00 4.50/10.20/11.00
2.50/7.03/8.50 3.70/11.30 13.70
5.40
9.70
5.00
8.30
3.70
8.20
7.03
10.20
5.54/7.80
9.30/10.30
-10~46
-10~46
-15~24
-15~24
6.1
6.0
4.0/4.8
4.0/5.0
A++
A+
A+/A++
A+/A++
403/1937/2277 588/3244/2894
3.0/3.2
2.7/3.4
16
23
3.68
4.80
220-240/1/50
220-240/1/50
2.05
3.65
3/8 - 5/8
3/8 - 5/8
3/40
3/50
20
25
30
30
42HK24VSC
42HK36VSC
61
65
49/46/43
53/51/48
1350/1200/1070 1800/1600/1400
24.5/30.0
27.5/31.5
5.0/8.0
5.0/8.0
840 x 840 x 245 840 x 840 x 245
950 x 950 x 55
950 x 950 x 55
38HU24VSC
38HU36VSC
69
70
61
64
2700
4150
50.0/54.5
70.5/76.1
845 x 363 x 702 946 x 410 x 810
1,472
2,164
** Sound data in cooling mode
Accessories
Description
Wired remote control for LC range - KJR-12- G2
Centralised wired remote control for LC range connectable up to 64 units - CCM-30
Part Number
7511630
7511631
Price, £
73
364
10
A leader in Cooling, Heating and Indoor Air Quality
www.cdlweb.info
email: sales@cooldesignsltd.co.uk
tel.: 0191 549 6964
SALSA
Cassette air conditioner
Inverter - R410A
Model
Indoor unit
Indoor unit panel
Outdoor unit
Cooling capacity
Heating capacity*
P design capacity cooling
P design capacity heating
Temperature range
SEER
SCOP
Energy label
Min./nom./max.
Min./nom./max.
@ -7°C
@ -10°C
@ -15°C
Warmer/average
Cooling
Heating
Warmer/average
SEER
SCOP warmer/average
kW
kW
kW
kW
kW
kW
kW
°C
°C
W/W
W/W
Yearly energy consumption
kWh
EER/COP
W/W
Rated current
A
Rated input
kW
Power supply
V/ph/Hz
Refrigerant amount
R410A
kg
Liquid side - gas side
inch
Standard piping length
Min./max. piping length
m
Max. height difference
m
Additional charge
g/m
Indoor unit
Sound power level**
dB(A)
Sound pressure level**
High/med./low
dB(A)
Air flow
High/med./low
m3/h
Weight
Body
kg
Panel
kg
Dimension
Body W x D x H
mm
Panel W x D x H
mm
Outdoor unit
Sound power level**
dB(A)
Sound pressure level**
dB(A)
Air flow
m3/h
Weight
kg
Dimension
WxDxH
mm
System retail price
* -7°C/-10°C/-15°C heating at free frequency
£
SALSA 36HVT
42HK36VSC
40CAS-L9
38HU36VTC
3.80/10.20/11.50
2.90/11.30/13.80
9.60
8.20
8.10
10.20
9.60/10.20
-10~46
-15~24
5.9
4.0/5.0
A+
A+/A++
610/3360/2885
2.6/3.4
12
4.80
380-415/3/50
3.65
3/8 - 5/8
3/50
25
30
42HK36VSC
65
53/51/48
1800/1600/1400
27.5/31.5
5.0/8.0
840 x 840 x 245
950 x 950 x 55
38HU36VTC
70
64
4150
85.3/91.0
946 x 410 x 810
2,332
SALSA 48HV
42HK48VSC
40CAS-L9
38HU48VSC
4.80/13.40/14.00
5.40/15.50/16.00
10.40
9.90
8.40
13.40
10.70/11.80
-10~46
-15~24
5.5
4.0/5.0
A
A+/A++
852/3756/3323
2.4/2.9
26.5
6.10
220-240/1/50
4.00
3/8 - 5/8
3/50
25
30
42HK48VSC
67
51/49/47
1900/1600/1330
28/32,1
5.0/8.0
840 x 840 x 245
950 x 950 x 55
38HU48VSC
75
64
6800
95.1/108.4
952 x 415 x 1333
2,611
SALSA 48HVT
42HK48VSC
40CAS-L9
38HU48VTC
4.80/13.40/14.00
5.40/15.50/16.00
10.50
10.00
8.50
13.40
11.00/11.80
-10~46
-15~24
5.6
4.0/5.1
A+
A+/A+++
834/3847/3231
2.5/3.0
13
6.10
380-415/3/50
4.00
3/8 - 5/8
3/50
25
30
42HK48VSC
67
51/49/47
1900/1600/1330
28/32,1
5.0/8.0
840 x 840 x 245
950 x 950 x 55
38HU48VTC
75
64
6800
108.1/121.2
952 x 415 x 1333
2,641
SALSA 60HV
42HK60VSC
40CAS-L9
38HU60VTC
5.00/15.10/16.00
3.90/18.00/18.20
12.20
11.90
9.80
15.10
11.20/12.10
-10~46
-15~24
5.7
4.0/5.2
A+
A+/A+++
929/3916/3225
2.4/3.1
14
7.50
380-415/3/50
4.30
3/8 - 5/8
3/50
25
30
42HK60VTC
70
54/52/49
2000/1780/1580
31.0/34.0
5.0/8.0
840 x 840 x 245
950 x 950 x 55
38HU60VTC
77
64
7000
112.8/126.0
952 x 415 x 1333
2,764
** Sound data in cooling mode
11
A leader in Cooling, Heating and Indoor Air Quality
www.cdlweb.info
email: sales@cooldesignsltd.co.uk
tel.: 0191 549 6964
TWIST
Ducted air conditioner
•
•
•
•
•
•
Inverter - R410A
Model
Indoor unit
Outdoor unit
Cooling capacity
Heating capacity*
P design capacity cooling
P design capacity heating
Temperature range
SEER
SCOP
Energy label
Min./nom./max.
Min./nom./max.
@ -7°C
@ -10°C
@ -15°C
Warmer/average
Cooling
Heating
Warmer/average
SEER
SCOP warmer/average
kW
kW
kW
kW
kW
kW
kW
°C
°C
W/W
W/W
Yearly energy consumption
kWh
EER/COP
W/W
Rated current
A
Rated input
kW
Power supply
V/ph/Hz
Refrigerant amount
R410A
kg
Liquid side - gas side
inch
Standard piping length
Min./max. piping length
m
Max. height difference
m
Additional charge
g/m
Indoor unit
Sound power level**
dB(A)
Sound pressure level**
High/med./low
dB(A)
Air flow
High/med./low
m3/h
Weight
kg
Dimension
WxDxH
mm
Outdoor unit
Sound power level**
dB(A)
Sound pressure level**
dB(A)
Air flow
m3/h
Weight
kg
Dimension
WxDxH
mm
System retail price
* -7°C/-10°C/-15°C heating at free frequency
£
Infra-red controller as standard (wired available).
Full Wi-Fi compatibility.
Slim and compact design.
High static pressure up to 160 Pa.
Variable static pressure setting.
Anti-cold draught function.
TWIST 12HV
42HY12VSC
38HU12VSC
1.40/3.52/3.90
1.20/3.80/4.20
2.50
2.20
2.00
3.52
2.83/3.44
-10~46
-15~24
6.1
4.0/5.1
A++
A+/A+++
202/985/941
2.8/3.2
10
2.30
220-240/1/50
1.05
1/4 - 3/8
3/25
10
15
42HY12VSC
60
42/38/35
540/500/370
18.5/23.0
915 x 655 x 290
38HU12VSC
65
56
2100
28.5/31.5
800 x 333 x 554
836
TWIST 18HV
42HY18VSC
38HU18VSC
2.00/5.00/5.50
2.00/5.40/6.00
4.00
3.60
2.50
5.00
4.20/5.34
-10~46
-15~24
6.3
4.0/5.1
A++
A+/A+++
277/1468/1465
2.8/3.6
11
2.53
220-240/1/50
1.70
1/4 - 1/2
3/30
20
15
42HY18VSC
60
42/40/38
790/660/490
23.0/29.0
880 x 674 x 210
38HU18VSC
65
57
2100
38.0/40.5
800 x 333 x 554
1,161
TWIST 24HV
42HY24VSC
38HU24VSC
2.50/7.03/7.70
2.40/7.40/8.70
5.30
4.70
3.50
7.03
5.20/7.50
-10~46
-15~24
6.1
4.0/5.1
A++
A+/A+++
401/1820/2058
3.1/3.4
16
3.68
220-240/1/50
2.05
3/8 - 5/8
3/40
20
30
42HY24VSC
61
43/40/38
1120/900/420
30.2/37.3
1305 x 805 x 305
38HU24VSC
69
61
2700
50.0/54.5
845 x 363 x 702
TWIST 36HV
42HY36VSC
38HU36VSC
3.70/10.20/11.00
3.00/12.70/14.00
10.30
9.60
8.30
10.20
10.30/10.60
-10~46
-15~24
6.2
4.0/5.1
A++
A+/A+++
574/3598/2888
2.6/3.7
23
4.30
220-240/1/50
3.65
3/8 - 5/8
3/50
25
30
42HY36VSC
65
47/42/42
1900/1550/1200
40.5/48.5
1360 x 774 x 249
38HU36VSC
70
64
4150
70.5/76.1
946 x 410 x 810
Part Number
7511630
7511631
Price, £
73
364
1,511
2,330
** Sound data in cooling mode
Accessories
Description
Wired remote control for LC range - KJR-12- G2
Centralised wired remote control for LC range connectable up to 64 units - CCM-30
12
A leader in Cooling, Heating and Indoor Air Quality
www.cdlweb.info
email: sales@cooldesignsltd.co.uk
tel.: 0191 549 6964
TWIST
Ducted air conditioner
Inverter - R410A
Model
Indoor unit
Outdoor unit
Cooling capacity
Heating capacity*
P design capacity cooling
P design capacity heating
Temperature range
SEER
SCOP
Energy label
Min./nom./max.
Min./nom./max.
@ -7°C
@ -10°C
@ -15°C
Warmer/average
Cooling
Heating
Warmer/average
SEER
SCOP warmer/average
kW
kW
kW
kW
kW
kW
kW
°C
°C
W/W
W/W
Yearly energy consumption
kWh
EER/COP
W/W
Rated current
A
Rated input
kW
Power supply
V/ph/Hz
Refrigerant amount
R410A
kg
Liquid side - gas side
inch
Standard piping length
Min./max. piping length
m
Max. height difference
m
Additional charge
g/m
Indoor unit
Sound power level**
dB(A)
Sound pressure level**
High/med./low
dB(A)
Air flow
High/med./low
m3/h
Weight
kg
Dimension
WxDxH
mm
Outdoor unit
Sound power level**
dB(A)
Sound pressure level**
dB(A)
Air flow
m3/h
Weight
kg
Dimension
WxDxH
mm
System retail price
* -7°C/-10°C/-15°C heating at free frequency
£
TWIST 36HVT
42HY36VSC
38HU36VTC
3.60/10.20/11.00
2.70/12.70/13.50
9.90
9.10
8.10
10.20
10.00/10.30
-10~46
-15~24
6.2
4.0/5.0
A++
A+/A++
577/3481/2912
2.6/3.7
12
4.80
380-415/3/50
3.65
3/8 - 5/8
3/50
25
30
42HY36VSC
65
47/45/43
1900/1550/1200
40.5/48.5
1360 x 774 x 249
38HU36VTC
70
64
4150
85.3/91.0
1090 x 500 x 875
2,497
TWIST 48HV
42HY48VSC
38HU48VSC
5.10/13.70/14.40
4.40/15.40/16.40
10.80
10.30
8.90
13.70
10.30/11.60
-10~46
-15~24
5.8
4.0/4.9
A+
A+/A++
826/3597/3337
2.7/3.5
26.5
6.10
220-240/1/50
4.00
3/8 - 5/8
3/50
25
30
42HY48VSC
71
53/51/49
2400/2050/1750
46.0/55.0
1200 x 874 x 300
38HU48VSC
75
64
6800
95.1/108.4
952 x 415 x 1333
2,706
TWIST 48HVT
42HY48VSC
38HU48VTC
4.90/13.70/14.20
4.70/15.40/16.90
11.60
10.70
9.10
13.70
11.50/12.40
-10~46
-15~24
5.9
4.0/5.4
A+
A+/A+++
813/4030/3206
2.6/3.7
13
6.10
380-415/3/50
4.00
3/8 - 5/8
3/50
25
30
42HY48VSC
71
53/51/49
2400/2050/1750
46.0/55.0
1200 x 874 x 300
38HU48VTC
75
64
6800
108.1/121.2
952 x 415 x 1333
2,735
TWIST 60HV
42HY60VSC
38HU60VTC
5.20/15.40/16.00
4.80/17.60/18.80
12.60
11.80
10.20
15.40
12.00/12.20
-10~46
-15~24
5.5
4.0/5.1
A
A+/A+++
963/4196/3328
2.3/3.4
14
7.50
380-415/3/50
4.30
3/8 - 5/8
3/50
25
30
42HY60VTC
76
58/56/54
2500/2100/1800
46.0/55.0
1200 x 874 x 300
38HU60VTC
77
64
7000
112.8/126
952 x 415 x 1333
2,813
** Sound data in cooling mode
13
A leader in Cooling, Heating and Indoor Air Quality
www.cdlweb.info
email: sales@cooldesignsltd.co.uk
tel.: 0191 549 6964
Multi-split system
Outdoor units
•
•
•
•
•
•
Inverter - R410A
System
Indoor unit
Indoor unit type
Outdoor unit
Cooling capacity
Heating capacity
Temperature range
SEER/SCOP
Energy label
Yearly energy consumption
Rated current
Rated input
Power supply
Refrigerant amount
Liquid side - gas side
Max. piping length
Max. height difference
Max. height difference
Sound power/pressure level*
Air flow
Weight
Dimension
Price
System
Indoor unit
Indoor unit type
Outdoor unit
Cooling capacity
Heating capacity
Temperature range
SEER/SCOP
Energy label
Yearly energy consumption
Rated current
Rated input
Power supply
Refrigerant amount
Liquid side - gas side
Max. piping length
Max. height difference
Max. height difference
Sound power/pressure level*
Air flow
Weight
Dimension
Price
Nom.
Nom.
Cooling/heating
SEER
SCOP Average
kW
kW
°C
W/W
kWh
A
kW
V/ph/Hz
R410A
kg
inch
Total/indoor unit
m
Indoor to outdoor
m
Between 2 indoors
m
dB(A)
m3/h
kg
WxDxH
mm
Indoor unit
Outdoor unit
Nom.
Nom.
Cooling/heating
SEER
SCOP Average
R410A
Total/indoor unit
Indoor to outdoor
Between 2 indoors
WxDxH
Indoor unit
Outdoor unit
* Sound data in cooling mode
£
£
kW
kW
°C
W/W
kWh
A
kW
V/ph/Hz
kg
inch
m
m
m
dB(A)
m3/h
kg
mm
£
£
Suitable for 2 to 5 indoor units off a single outdoor.
Infra-red remote control as standard.
Individual control for each indoor unit.
Mixed capacities available on outdoor units.
Up to 130% connected capacity available.
Automatic correction of wiring crossover.
2-way multi
42HV09VSC x 2
42HC09VSC x 2
High-wall
Console
38HM18VSC
38HM18VSC
5.30
5.20
5.60
5.90
-10~46/-15~24
-10~46/-15~24
6.62/3.91
5.65/3.80
A++
A+
A
A
280/1780
322/1916
12
12
2.30
2.30
220-240/1/50
220-240/1/50
1.90
1.90
1/4 - 3/8
1/4 - 3/8
40/25
40/25
15
15
10
10
66/59.5
66/59.5
2700
2700
49
49
845 x 363 x 702
845 x 363 x 702
3-way multi
42HV09VSC x 3
42HC09VSC x 3
High-wall
Console
38HM27VSC
38HM27VSC
7.92
7.92
8.20
8.20
-10~46/-15~24
-10~46/-15~24
6.10/4.00
6.10/4.00
A++
A++
A+
A+
454/2030
454/1995
16
16
3.30
3.30
220-240/1/50
220-240/1/50
2.10
2.10
1/4 - 3/8
1/4 - 3/8
60/30
60/30
15
15
10
10
68/61
68/61
2700
2700
53
53
845 x 363 x 765
845 x 363 x 765
4-way multi
42HV09VSC x 4
42HC09VSC x 4
High-wall
Console
38HM36VSC
38HM36VSC
10.60
10.60
11.20
11.20
-10~46/-15~24
-10~46/-15~24
5.90/3.80
5.80/3.80
A++
A++
A
A
626/3426
640/3353
21.5
21.5
4.60
4.60
220-240/1/50
220-240/1/50
3.00
3.00
3 x 1/4 - 3/8
3 x 1/4 - 3/8
1 x 1/4 - 1/2
1 x 1/4 - 1/2
80/35
80/35
15
15
10
10
68/63
68/63
4000
4000
70
70
946 x 410 x 810
946 x 410 x 810
5-way multi
42HV09VSC x 5
42HC09VSC x 5
High-wall
Console
38HM42VSC
38HM42VSC
12.30
12.30
12.50
12.50
-10~46/-15~24
-10~46/-15~24
5.60/3.80
5.80/3.80
A+
A+
A
A
769/3537
742/3463
22
22
4.70
4.70
220-240/1/50
220-240/1/50
3.60
3.60
4 x 1/4 - 3/8
4 x 1/4 - 3/8
1 x 1/4 - 1/2
1 x 1/4 - 1/2
80/35
80/35
15
15
10
10
68/63
68/63
4000
4000
76
76
946 x 410 x 810
946 x 410 x 810
2 x 129
845
4 x 129
1,579
2 x 326
845
4 x 326
1,579
3 x 129
996
5 x 129
1,584
3 x 326
996
5 x 326
1,584
14
A leader in Cooling, Heating and Indoor Air Quality
www.cdlweb.info
email: sales@cooldesignsltd.co.uk
tel.: 0191 549 6964
Multi-split system
Indoor units
The multi-split system allows the ability to
utilise different styles and capacity of units
to be connected to a single outdoor unit to
maximise flexibility.
Indoor unit
Mambo console
Stella high-wall
Salsa cassette
Twist ducted
Model number
Size
Approx. kW
Price, £
42HC09VSC
9k
2.6
£326
42HC12VSC
12k
3.5
£360
42HC18VSC
18k
4.4
£372
42HV09VSC
9k
2.7
£129
42HV12VSC
12k
3.5
£155
42HV18VSC
18k
5.3
£204
42HV22VSC
24k
6.4
£250
42HK09VSC
9k
2.6
£309
42HK12VSC
12k
3.5
£333
42HK18VSC
18k
5.0
£420
42HK24VSC
24k
7.0
£437
42HY12VSC
12k
3.5
£394
42HY18VSC
18k
5.0
£530
42HY24VSC
24k
7.0
£571
Note: kW capacity varies depending on total connected capacity.
15
A leader in Cooling, Heating and Indoor Air Quality
www.cdlweb.info
email: sales@cooldesignsltd.co.uk
tel.: 0191 549 6964
Multi-split system
Possible system combinations
MULTI-SPLIT 2 INDOOR UNITS
1 x indoor unit 2 x indoor unit
9
9+9
12
9+12
MULTI-SPLIT 3 INDOOR UNITS
1 x indoor unit
2 x indoor unit
9
9+9
12+12
12
9+12
12+18
18
9+18
18+18
3 x indoor unit
9+9+9
9+12+12
9+9+12
12+12+12
9+9+18
MULTI-SPLIT 4 INDOOR UNITS
1 x indoor unit
2 x indoor unit
9
9+9
12+12
12
9+12
12+18
18
9+18
12+24
24
9+24
18+18
9+9+9
9+9+12
9+9+18
9+9+24
3 x indoor unit
9+12+12
9+12+18
9+12+24
9+18+18
12+12+12
12+12+18
12+12+24
12+18+18
4 x indoor unit
9+9+9+9
9+9+12+18
9+9+9+12
9+12+12+12
9+9+9+18 12+12+12+12
9+9+12+12
MULTI-SPLIT 5 INDOOR UNITS
1 x indoor unit
2 x indoor unit
9
9+9
12+12
12
9+12
12+18
18
9+18
12+24
24
9+24
18+18
9+9+9
9+9+12
9+9+18
9+9+24
3 x indoor unit
9+12+12
9+12+18
9+12+24
9+18+18
12+12+12
12+12+18
12+12+24
12+18+18
9+9+9+9
9+9+9+12
9+9+9+18
9+9+9+24
4 x indoor unit
5 x indoor unit
9+9+12+12 9+12+12+18
9+9+9+9+9
9+9+12+18 12+12+12+12 9+9+9+9+12
9+9+12+24 12+12+12+18 9+9+9+9+18
9+12+12+12
9+9+9+12+12
Note:
1. The capacity is tested with standard 9K indoor unit as below:
18K condensing unit + 2 x 9K indoor units
27K condensing unit + 3 x 9K indoor units
36K condensing unit + 4 x 9K indoor units
42K condensing unit + 5 x 9K indoor units
2. 18K indoor units should apply 1/2” gas pipe with one additional adapter 3/8’’-1/2” required in condensing unit.
3. 24K indoor units should apply 3/8” liquid pipe with one additional adapter 1/4’’-3/8” required in indoor units, and apply 5/8” gas pipe with one
additional adapter 1/2’’-5/8” in condensing unit.
16
A leader in Cooling, Heating and Indoor Air Quality
3-Year
Warranty
Available
www.cdlweb.info
email: sales@cooldesignsltd.co.uk
tel.: 0191 549 6964
•
•
•
•
•
•
•
Easy installation with 12 pre-set climate curves.
Full inverter controlling the twin rotary compressor.
Reversible
New controller offers optimised control.
Integrated Hydraulic module A-class variable speed pump.
Water outlet temperature up to 60°C.
Defrost protection <-20°C.
Units supplied with flexible connections and anti-vibration mounts as standard.
EREBA
heat pump
EREBA
4H
6H
8H
12H
15H
12HT
15HT
17HT
21HT
Underfloor heating 30/35°C*
Heating to 7/6°C
kW
4.10
5.80
7.20
11.90
14.46
12.00
15.00
16.90
20.70
COP/SCOP
4.06/3.73 4.20/3.60 3.91/3.03 3.91/3.19 4.09/3.61 4.30/3.78 4.20/3.68 4.23/3.68 4.15/3.56
Energy class
A+
A+
A
A+
A+
A+
A+
A+
A+
Fan coil 40/45°C*
Heating to 7/6°C
kW
3.90
5.80
7.40
12.95
13.96
11.20
14.50
15.80
19.50
COP
3.20
3.01
3.16
3.01
3.23
3.35
3.30
3.44
3.32
Radiators 47/55°C*
Heating to 7/6°C
kW
4.10
5.40
6.70
11.50
11.66
11.43
12.17
15.00
20.80
COP/SCOP
2.72/3.53 2.58/3.37 2.30/2.84 2.48/2.95 2.82/3.25 3.12/3.47 2.98/3.33 2.68/3.03 2.50/2.85
Energy class
A++
A++
A+
A+
A++
A++
A++
A+
A+
Cooling mode 23/18°C**
Cooling to 35°C
kW
4.93
7.04
7.84
13.54
16.04
13.50
16.00
21.40
26.40
EER/ESEER
4.20/4.36 3.70/4.51 3.99/4.15 3.66/4.22 3.85/4.31 4.15/4.40 3.81/4.31 4.00/4.40 4.00/4.20
Sound power*
dB(A)
62
62
64
67
68
68
68
71
74
Power supply
V-ph-Hz
230-1-50
400-3- 50
Part Number
7422274
7422275
7422276
7422277
7422278
7422279
7422280
7469145
7469147
Price
£
3,742
4,048
4,316
6,245
6,799
6,608
7,086
7,908
9,206
* Following conditions NFPAC. Certified data NFPAC under No. NF414-1252 (except three-phase models).
** Following conditions EUROVENT LCP/A/CHF water 23/18°C, air 35°C.
Accessories
Description
Screen filter valve kit
Charging kit/1-1/4 filling kit
50 l 4-nozzle mixing tank
100 l 8-nozzle mixing tank
200 l 8-nozzle mixing tank
DUO hydraulic module
5 kW single-phase loop heater (only available for sizes 4H-15H)
9 kW three-phase loop heater (only available for sizes 12HT-21HT)
9 kW back-up heater for mounting in 200 l tank
300 l DHW tank
3-way valve for DHW 300 l
DHW sensor & 3-way valve kit (required with 300 l DHW tank)
Underfloor heating/cooling system limiter thermostat
Sensor for 4 units operating in parallel – modular configuration
Outdoor sensor
Pool heating kit (sensor + 3-way valves)
ITEX exchanger pool+ Ti 24
Sizes 4H-15H/HT
7166295
7013876
7328746
7328744
7328747
3911008
7148641
7148642
7385910
7422270
7422271
-
Price, £
73
82
335
421
730
1,397
761
924
1,195
299
68
-
Sizes 17H/HT–21HT
Included
7013877
7328744
7328747
3911008
7148642
7221389
7385910
7422270
7411357
7274278
7484985
7484983
7111122
7268481
Price, £
95
421
730
1,397
924
383
1,195
299
445
68
34
30
445
824
17
A leader in Cooling, Heating and Indoor Air Quality
www.cdlweb.info
email: sales@cooldesignsltd.co.uk
tel.: 0191 549 6964
EREBA performance tables
Cooling capacities
EREBA
Chilled
water
temp.,°C
5
15
CC kW
PI kW
CC kW
PI kW
Nom. Min. Max. Nom. Min. Max. Nom. Min. Max. Nom. Min.
4H
1.3 1.2 1.3 0.2 0.1 0.2 1.2 1.1 1.2 0.2 0.1
6H
1.1 1.0 1.1 0.1 0.1 0.1 1.0 0.9 1.0 0.1 0.1
8H
6.2 0.6 7.3 0.7 0.1 0.9 5.6 0.5 6.7 1.0 0.1
12H
14.7 4.6 17.0 2.5 0.5 3.5 11.8 4.3 13.4 2.4 0.7
12HT
13.8 4.5 19.7 2.3 0.5 4.5 11.4 4.1 15.9 2.2 0.7
5
15H
19.1 4.5 20.0 3.7 0.5 4.2 15.3 4.2 15.7 3.3 0.7
15HT
19.1 4.5 20.0 3.7 0.5 4.2 15.3 4.2 15.7 3.3 0.7
17HT
15.4 9.9 15.4 3.4 1.7
21HT
20.5 12.8 24.5 4.4 3.9
4H
1.4 1.3 1.4 0.2 0.1 0.2 1.3 1.2 1.3 0.2 0.1
6H
1.3 1.2 1.3 0.1 0.1 0.1 1.1 1.0 1.1 0.1 0.1
8H
6.9 0.7 8.0 0.8 0.1 0.9 6.3 0.6 7.2 1.0 0.1
12H
13.6 5.1 15.6 1.8 0.5 2.3 12.6 4.7 14.4 2.4 0.7
7
12HT
12.8 4.9 17.8 1.6 0.5 2.6 12.1 4.5 16.9 2.1 0.6
15H
17.4 5.0 18.1 2.3 0.5 2.6 16.0 4.6 16.7 3.1 0.6
15HT
17.4 5.0 18.1 2.3 0.5 2.6 16.0 4.6 16.7 3.1 0.6
17HT
16.3 10.5 16.3 3.5 1.7
21HT
21.6 13.5 26.3 4.6 4.0
1.5 1.3 1.5 0.2 0.1
4H
6H
1.4 1.3 1.4 0.1 0.1 0.1 1.3 1.2 1.3 0.1 0.1
8H
7.9 0.9 8.9 0.8 0.1 1.0 7.2 0.8 8.1 1.1 0.1
12H
12.1 5.9 13.5 1.2 0.5 1.4 13.7 5.4 15.9 2.4 0.7
12HT
11.4 5.6 15.0 1.0 0.4 1.5 13.3 5.2 18.4 2.1 0.6
10
15H
14.7 5.7 15.3 1.4 0.4 1.4 17.0 5.3 18.2 3.0 0.6
15HT
14.7 5.7 15.3 1.4 0.4 1.4 17.0 5.3 18.7 3.0 0.6
17HT
17.8 6.2 17.8 3.6 0.7
21HT
23.3 8.1 28.7 4.8 1.7
4H
6H
1.6 1.6 1.6 0.1 0.1 0.1 1.6 1.4 1.6 0.1 0.1
8H
9.7 1.1 10.5 0.9 0.1 1.1 8.8 1.0 9.6 1.2 0.1
12H
7.1 7.1 7.1 0.5 0.5 0.5 15.5 6.6 18.4 2.4 0.6
12HT
6.8 6.8 6.8 0.4 0.4 0.4 15.1 6.3 20.9 2.0 0.5
15
15H
6.9 6.9 6.9 0.4 0.4 0.4 18.8 6.4 20.7 2.8 0.5
15HT
6.9 6.9 6.9 0.4 0.4 0.4 18.8 6.4 20.7 2.8 0.5
17HT
20.4 7.0 20.4 3.8 0.7
21HT
27.3 9.5 33.3 4.8 1.6
4H
6H
1.8 1.8 1.8 0.1 0.1 0.1 1.7 1.6 1.7 0.1 0.1
8H
10.7 1.3 11.5 1.0 0.1 1.1 9.8 1.2 10.5 1.2 0.1
12H
7.9 7.9 7.9 0.5 0.5 0.5 16.6 7.3 19.9 2.4 0.6
18
12HT
7.5 7.5 7.5 0.4 0.4 0.4 16.3 6.9 22.4 1.9 0.5
15H
7.7 7.7 7.7 0.4 0.4 0.4 19.8 7.1 22.2 2.7 0.5
15HT
7.7 7.7 7.7 0.4 0.4 0.4 19.8 7.1 22.2 2.7 0.5
17HT
22.0 7.1 22.0 4.0 0.8
21HT
29.8 9.9 36.3 4.9 1.8
PI Power input, kW (power input values include the compressor, fans and control)
CC Cooling capacity, kW
Max.
0.2
0.1
1.2
3.0
3.5
3.3
3.3
3.4
6.3
0.2
0.1
1.2
3.1
3.5
3.4
3.4
3.5
6.4
0.2
0.1
1.3
3.4
3.7
3.5
3.5
3.6
6.5
0.1
1.3
3.7
3.8
3.7
3.7
3.8
6.8
0.1
1.3
3.9
3.9
3.8
3.8
4.0
7.0
Outdoor air temperature, °C
25
CC kW
PI kW
Nom. Min. Max. Nom. Min. Max.
3.5 0.9 3.5 1.0 0.2 1.0
5.2 0.8 5.2 1.4 0.1 1.4
5.1 0.5 6.0 1.3 0.1 1.6
10.8 3.9 12.2 2.9 0.9 3.6
10.4 3.7 14.5 2.8 0.9 4.2
14.0 3.8 14.3 3.9 0.9 4.0
14.0 3.8 14.3 3.9 0.9 4.0
14.5 9.0 14.5 3.8 2.0 3.8
19.9 13.8 23.8 4.9 3.2 6.9
3.8 1.0 3.8 1.0 0.2 1.0
5.6 0.9 5.6 1.4 0.1 1.4
5.6 0.6 6.5 1.3 0.1 1.6
11.5 4.3 13.1 3.0 0.9 3.7
11.1 4.1 15.4 2.8 0.8 4.2
14.6 4.2 15.2 3.8 0.8 4.1
14.6 4.2 15.2 3.8 0.8 4.1
15.6 9.6 15.6 3.8 2.0 3.8
21.1 14.7 25.2 5.0 3.3 7.1
4.3 1.2 4.3 1.0 0.2 1.0
6.3 1.0 6.3 1.5 0.1 1.5
6.5 0.7 7.3 1.4 0.1 1.7
12.5 4.9 14.5 3.0 0.9 4.0
12.2 4.7 16.7 2.7 0.8 4.3
15.5 4.8 16.6 3.7 0.8 4.2
15.5 4.8 16.6 3.7 0.8 4.2
17.1 5.2 17.1 3.9 1.2 3.9
22.9 8.4 27.3 5.2 1.9 7.4
5.1 1.4 5.1 1.0 0.2 1.0
7.4 1.2 7.4 1.6 0.1 1.6
8.0 0.9 8.7 1.5 0.1 1.7
14.1 6.0 16.8 3.0 0.9 4.3
14.1 5.7 19.0 2.7 0.8 4.4
17.1 5.8 18.8 3.5 0.8 4.3
17.1 5.8 18.8 3.5 0.8 4.3
19.8 6.1 19.8 4.0 1.1 4.0
26.2 9.8 31.0 5.4 1.9 7.9
5.6 1.6 5.6 1.0 0.2 1.0
8.1 1.4 8.1 1.6 0.1 1.6
8.9 1.1 9.5 1.6 0.1 1.8
15.1 6.6 18.1 3.1 0.9 4.5
15.2 6.3 20.4 2.6 0.7 4.5
18.0 6.4 20.2 3.4 0.7 4.4
18.0 6.4 20.2 3.4 0.7 4.4
21.5 7.0 21.9 4.1 0.9 4.2
28.3 10.8 33.3 5.6 1.8 8.2
35
CC kW
PI kW
Nom. Min. Max. Nom. Min.
3.0 0.8 3.1 1.1 0.2
4.3 0.7 4.9 1.5 0.1
4.5 0.4 5.3 1.6 0.1
9.6 3.5 10.9 3.5 1.1
9.6 3.3 13.0 3.4 1.0
12.5 3.4 12.9 4.5 1.0
12.5 3.4 12.9 4.5 1.0
14.3 3.0 14.8 4.7 1.3
18.1 8.3 22.3 5.8 2.5
3.3 0.9 3.5 1.1 0.2
4.7 0.7 5.3 1.6 0.1
5.0 0.5 5.8 1.7 0.1
10.2 3.8 11.7 3.5 1.1
10.2 3.7 13.7 3.4 1.0
13.0 3.8 13.6 4.5 1.0
13.0 3.8 13.6 4.5 1.0
15.2 3.2 15.8 4.8 1.3
19.1 8.9 23.6 6.0 2.5
3.7 1.0 3.9 1.2 0.2
5.3 0.9 5.9 1.7 0.1
5.8 0.6 6.5 1.8 0.1
11.1 4.4 12.9 3.6 1.1
11.1 4.2 14.7 3.4 1.0
13.8 4.3 14.6 4.4 1.0
13.8 4.3 14.6 4.4 1.0
16.6 3.6 17.3 5.0 1.3
20.9 9.7 25.6 6.4 2.7
4.5 1.3 4.7 1.2 0.2
6.4 1.1 6.9 1.9 0.1
7.0 0.8 7.7 1.9 0.2
12.6 5.3 14.9 3.7 1.2
12.6 5.1 16.5 3.3 1.0
15.2 5.2 16.3 4.3 1.0
15.2 5.2 16.3 4.3 1.0
19.2 4.2 19.9 5.2 1.2
23.9 11.2 29.1 6.8 2.7
4.9 1.4 5.2 1.2 0.2
7.0 1.2 7.5 1.9 0.2
7.8 1.0 8.4 2.0 0.2
13.5 5.9 16.1 3.7 1.2
13.5 5.6 17.5 3.3 1.0
16.0 5.7 17.3 4.2 1.0
16.0 5.7 17.3 4.2 1.0
21.4 4.6 21.6 5.4 1.2
26.4 12.2 31.3 6.6 2.8
Max.
1.2
2.0
1.9
4.2
4.9
4.8
4.8
5.0
8.3
1.2
2.0
2.0
4.4
4.9
4.8
4.8
5.1
8.5
1.3
2.1
2.1
4.6
4.9
4.8
4.8
5.3
8.8
1.3
2.2
2.2
4.9
5.0
4.8
4.8
5.6
9.4
1.4
2.2
2.2
5.0
5.0
4.8
4.8
5.6
9.8
45
CC kW
PI kW
Nom. Min. Max. Nom. Min.
2.7 0.7 2.8 1.3 0.2
3.8 0.5 4.4 1.8 0.1
3.9 0.4 4.6 1.9 0.1
8.4 3.0 9.5 4.1 1.3
8.9 2.8 9.6 3.7 1.2
9.2 2.9 9.5 4.2 1.2
9.2 2.9 9.5 4.2 1.2
12.3 4.0 12.3 5.2 2.7
15.2 6.5 16.4 6.4 2.8
2.9 0.8 3.1 1.3 0.2
4.2 0.6 4.7 1.9 0.1
4.4 0.4 5.1 2.0 0.2
8.7 3.3 9.9 4.1 1.3
9.3 3.1 10.2 3.6 1.2
9.8 3.2 10.1 4.3 1.2
9.8 3.2 10.1 4.3 1.2
13.1 4.2 13.1 5.3 2.8
16.1 6.9 17.4 6.6 2.8
3.3 0.9 3.4 1.3 0.2
4.7 0.7 5.2 2.0 0.1
5.0 0.6 5.7 2.1 0.2
9.1 3.7 10.6 4.0 1.4
10.0 3.6 11.2 3.5 1.2
10.7 3.7 11.0 4.4 1.2
10.7 3.7 11.0 4.4 1.2
14.3 4.7 14.4 5.5 2.8
17.6 7.6 19.0 6.8 2.9
3.9 1.1 4.0 1.4 0.2
5.6 0.9 6.0 2.2 0.2
6.2 0.7 6.8 2.3 0.2
9.9 4.5 11.7 3.8 1.4
11.1 4.3 12.8 3.4 1.2
12.2 4.4 12.6 4.5 1.2
12.2 4.4 12.6 4.5 1.2
16.7 5.4 16.7 5.8 2.9
20.2 8.8 21.8 7.1 3.0
4.3 1.2 4.4 1.4 0.2
6.2 1.0 6.5 2.3 0.2
0.9 0.9 0.9 0.2 0.2
10.3 5.0 12.4 3.7 1.5
11.8 4.8 13.7 3.3 1.2
13.0 4.9 13.6 4.6 1.2
13.0 4.9 13.6 4.6 1.2
18.5 5.9 18.5 5.9 2.9
21.9 9.6 23.6 7.3 3.0
Max.
1.4
2.3
2.4
5.0
4.5
4.4
4.4
5.2
7.1
1.4
2.3
2.4
5.0
4.6
4.4
4.4
5.3
7.2
1.4
2.3
2.5
5.0
4.7
4.5
4.5
5.5
7.5
1.4
2.4
2.6
5.0
4.8
4.7
4.7
5.8
7.9
1.4
2.4
0.2
5.0
4.9
4.7
4.7
5.9
8.1
Evaporator entering/leaving water temperature difference: 5 K
Evaporator fluid: chilled water
Fouling factor: 0 m 2 K/W
Performances in accordance with EN14511-3:2011.
18
A leader in Cooling, Heating and Indoor Air Quality
www.cdlweb.info
email: sales@cooldesignsltd.co.uk
tel.: 0191 549 6964
EREBA performance tables
Heating capacities
Leaving hot water temperature, °C
Comfort unit
Radiator
EREBA
Outdoor air
45
55
temp., °C
HC kW
PI kW
HC kW
PI kW
HC kW
PI kW
HC kW
Nom. Min. Max. Nom. Min. Max. Nom. Min. Max. Nom. Min. Max. Nom. Min. Max. Nom. Min. Max. Nom. Min.
4H
1.2
0.5
1.2
1.1
0.3
1.1
1.2
0.4
1.2
1.1
0.2
1.1
0.4
0.4
0.4
0.2
0.2
0.2
6H
3.0
0.5
3.1
1.5
0.2
1.6
1.4
0.4
1.4
0.8
0.2
0.8
0.4
0.4
0.4
0.3
0.3
0.3
8H
1.8
0.6
1.8
0.7
0.2
0.7
1.3
0.6
1.3
0.6
0.3
0.6
0.5
0.5
0.5
0.3
0.3
0.3
12H
3.2
1.5
3.2
1.5
0.7
1.5
3.0
1.2
3.0
1.5
0.6
1.5
1.1
1.1
1.1
0.7
0.7
0.7
12HT
4.0
1.3
4.0
2.1
0.7
2.1
3.0
1.4
3.0
1.7
0.8
1.7
1.3
1.3
1.3
0.8
0.8
0.8
-20
15H
4.5
1.3
4.5
2.5
0.7
2.5
3.0
1.3
3.0
1.8
0.7
1.8
1.3
1.3
1.3
0.8
0.8
0.8
15HT
4.5
1.4
4.5
2.5
0.7
2.5
3.0
1.4
3.0
1.8
0.8
1.8
1.3
1.3
1.3
0.8
0.8
0.8
17HT
4.3
2.2
4.4
2.3
1.0
2.3
4.1
2.1
4.2
2.6
1.2
2.6
21HT
6.2
4.0
6.3
3.2
2.0
3.2
5.7
4.7
5.7
3.7
3.1
3.7
4H
2.4
0.5
2.7
1.2
0.2
1.4
2.3
0.4
2.6
1.2
0.2
1.4
1.2
0.4
1.2
0.7
0.2
0.7
6H
3.2
0.6
3.3
1.4
0.2
1.5
3.2
0.6
3.2
1.5
0.3
1.6
1.6
0.6
1.6
0.9
0.3
0.9
8H
3.2
0.7
3.7
1.3
0.3
1.9
3.4
0.7
3.6
1.6
0.3
2.2
0.8
0.7
0.8
0.4
0.3
0.4
12H
6.4
2.0
7.3
2.8
0.8
3.2
6.0
1.8
6.8
2.9
0.9
3.3
2.9
1.7
2.9
1.7
1.0
1.7
12HT
6.7
1.7
7.5
2.7
0.7
3.0
6.4
1.8
7.2
3.5
0.8
4.0
2.9
1.7
2.9
1.7
0.9
1.7
-15
15H
7.4
1.6
8.3
3.1
0.7
3.6
7.1
1.6
8.0
3.4
0.7
3.9
3.0
1.5
3.0
1.7
0.9
1.7
15HT
7.4
1.8
8.4
3.0
0.7
3.4
7.1
1.6
8.0
3.9
0.8
4.5
3.0
1.6
3.0
1.7
0.9
1.7
17HT
5.1
2.6
5.0
2.5
1.1
2.5
4.8
2.4
4.8
2.8
1.3
2.8
21HT
7.4
4.8
7.4
3.4
2.1
3.4
6.9
5.7
6.9
4.0
3.3
4.0
4H
2.5
0.5
2.8
1.0
0.2
1.2
2.4
0.5
2.6
1.1
0.2
1.3
2.4
0.4
2.5
1.4
0.2
1.4
2.2
0.4
6H
3.4
0.6
3.5
1.4
0.2
1.5
3.5
0.6
3.5
1.6
0.3
1.7
3.3
0.6
3.3
1.7
0.3
1.8
3.0
0.6
8H
3.8
0.8
4.2
1.4
0.3
2.0
3.9
0.8
4.0
1.7
0.3
2.4
3.6
0.7
4.0
1.9
0.4
2.4
1.8
0.7
12H
6.9
2.1
7.4
2.8
0.8
3.0
6.6
2.0
7.5
3.0
0.9
3.5
6.4
1.9
7.2
3.5
1.1
4.0
6.1
1.9
12HT
7.1
1.9
8.7
2.7
0.7
3.5
5.9
1.8
8.7
2.6
0.8
4.0
5.8
1.7
7.0
3.1
0.9
3.8
5.4
1.5
-7
15H
7.8
1.8
9.1
3.1
0.7
3.7
7.7
1.8
9.1
3.5
0.8
4.2
7.4
1.7
7.9
4.0
0.9
4.6
6.6
1.5
15HT
8.0
1.9
9.5
3.1
0.7
3.9
8.0
1.8
9.4
3.5
0.8
4.4
6.5
1.7
7.9
3.5
0.9
4.5
6.7
1.5
17HT
7.1
2.4
10.3
3.0
0.9
5.0
6.8
2.2
9.9
3.4
1.0
5.7
7.0
2.1
8.3
3.7
1.2
4.6
6.8
2.1
21HT
10.2
6.4
15.0
4.0
2.3
6.7
9.5
7.4
14.4
4.7
3.6
7.9
8.9
6.9
11.1
5.5
4.3
7.0
4H
2.8
0.6
3.1
1.1
0.2
1.1
2.7
0.5
3.0
1.1
0.2
1.3
2.8
0.5
2.8
1.4
0.2
1.5
2.6
0.4
6H
3.8
0.7
3.8
1.4
0.2
1.4
3.8
0.7
3.8
1.6
0.3
1.7
3.7
0.7
3.8
1.8
0.3
1.9
3.4
0.6
8H
4.4
0.9
4.8
1.6
0.3
2.0
4.5
0.9
4.8
1.9
0.3
2.6
4.2
0.8
4.6
2.1
0.4
2.6
2.1
0.7
12H
7.8
2.4
8.9
2.7
0.8
3.1
7.4
2.3
8.4
3.2
1.0
3.7
7.4
2.3
8.4
3.8
1.1
4.3
6.9
2.1
-3
12HT
7.7
2.1
9.5
2.7
0.7
3.5
6.2
2.0
9.4
2.6
0.8
4.1
6.4
1.9
7.5
3.2
0.9
3.8
5.9
1.7
15H
9.0
2.0
10.2
3.2
0.7
3.7
9.0
2.0
10.2
3.8
0.8
4.4
8.0
1.9
8.4
4.0
0.9
4.5
6.8
1.7
15HT
8.5
2.1
10.5
3.1
0.7
3.9
8.4
2.0
10.5
3.5
0.8
4.6
6.9
1.9
8.7
3.4
0.9
4.6
7.3
1.7
17HT
21HT
4H
2.9
0.6
3.3
1.0
0.2
1.1
2.8
0.6
3.2
1.1
0.2
1.3
3.0
0.5
3.1
1.5
0.2
1.5
2.8
0.5
6H
4.0
0.7
4.1
1.3
0.2
1.4
4.0
0.7
4.0
1.7
0.3
1.8
4.0
0.7
4.0
1.9
0.3
1.9
3.7
0.7
8H
4.7
1.0
5.2
1.6
0.3
2.1
4.8
1.0
5.2
2.0
0.4
2.6
4.5
0.9
5.0
2.2
0.4
2.7
2.2
0.8
12H
8.5
2.6
9.6
2.8
0.8
3.2
8.1
2.4
9.1
3.3
1.0
3.8
8.2
2.5
9.1
4.0
1.2
4.4
7.5
2.3
12HT
7.9
2.3
9.9
2.8
0.7
3.6
6.7
2.2
9.8
2.7
0.8
4.0
6.4
2.0
8.0
3.0
0.9
3.9
6.0
1.9
0
15H
9.0
2.1
11.1
3.0
0.7
3.7
9.7
2.1
11.1
4.0
0.8
4.6
8.3
2.0
8.7
4.0
0.9
4.5
7.0
1.9
15HT
8.7
2.3
11.2
3.1
0.7
4.1
8.6
2.1
11.0
3.5
0.8
4.7
7.6
2.0
9.0
3.6
0.9
4.5
7.5
1.9
17HT
21HT
PI Power input, kW (power input values include the compressor, fans and control)
HC Heating capacity, kW
Heating floor
35
60
Max. Nom.
2.5
1.3
3.1
1.8
2.2
1.2
6.9
3.9
6.7
3.5
7.6
4.0
7.5
4.4
6.9
3.9
2.8
1.3
3.5
1.9
2.5
1.2
7.8
4.1
7.4
3.8
7.9
3.8
8.3
4.8
3.0
1.4
3.8
1.9
2.7
1.3
8.5
4.3
7.6
3.7
8.2
3.8
8.5
4.8
-
PI kW
Min. Max.
0.2
1.4
0.3
1.9
0.4
1.4
1.2
4.5
1.0
4.4
0.9
4.7
1.0
5.3
1.2
4.0
0.2
1.5
0.3
2.0
0.4
1.5
1.2
4.7
1.1
4.8
1.0
4.5
1.1
5.7
0.2
1.6
0.3
2.1
0.4
1.6
1.3
4.9
1.1
4.8
1.0
4.5
1.1
5.6
-
Condenser entering/leaving water temperature difference: 5 K (for leaving water temperatures below 50°C)
Condenser fluid: water
Fouling factor: 0.000018 m 2 K/W
Performances in accordance with EN14511-3:2011.
19
A leader in Cooling, Heating and Indoor Air Quality
www.cdlweb.info
email: sales@cooldesignsltd.co.uk
tel.: 0191 549 6964
EREBA performance tables
Heating capacities (continued)
Leaving hot water temperature, °C
Comfort unit
Radiator
EREBA
Outdoor air
45
55
temp., °C
HC kW
PI kW
HC kW
PI kW
HC kW
PI kW
HC kW
Nom. Min. Max. Nom. Min. Max. Nom. Min. Max. Nom. Min. Max. Nom. Min. Max. Nom. Min. Max. Nom. Min.
4H
3.3
0.6
3.6
1.1
0.2
1.1
3.0
0.6
3.4
1.1
0.2
1.3
3.2
0.6
3.2
1.5
0.2
1.5
2.9
0.5
6H
4.2
0.8
4.3
1.4
0.2
1.5
4.2
0.8
4.2
1.7
0.3
1.8
4.2
0.8
4.2
1.9
0.3
1.9
3.9
0.7
8H
5.1
1.0
5.5
1.7
0.3
2.1
5.2
1.0
5.5
2.0
0.4
2.6
4.9
1.0
5.2
2.2
0.4
2.6
2.4
0.8
12H
8.8
2.9
10.1
2.8
0.9
3.3
8.5
2.7
9.6
3.2
1.0
3.7
8.7
2.7
9.6
3.9
1.2
4.4
7.9
2.5
12HT
8.6
2.6
11.0
2.7
0.8
3.6
7.5
2.5
10.6
2.8
0.9
4.1
7.5
2.3
8.7
3.3
1.0
4.0
7.1
2.1
2
15H
9.5
2.5
12.1
3.1
0.7
3.8
9.5
2.5
11.4
3.7
0.9
4.5
9.0
2.3
9.5
4.1
1.0
4.6
7.4
2.1
15HT
9.5
2.7
12.6
3.1
0.8
4.1
9.3
2.5
11.9
3.5
0.9
4.7
8.0
2.3
10.2
3.6
1.0
4.9
8.5
2.1
17HT
12.5
5.4
18.4
4.0
1.7
7.4
11.8
5.1
17.6
4.7
1.7
8.5
11.2
4.2
12.9
5.3
1.7
6.6
10.8
4.1
21HT
15.3
7.1
19.5
5.2
2.3
7.8
14.5
5.4
18.5
6.1
2.2
9.0
13.4
6.2
16.7
7.0
3.2
9.0
4H
4.1
0.8
4.7
1.0
0.2
1.2
3.9
0.7
4.5
1.2
0.2
1.4
4.1
0.7
4.2
1.5
0.2
1.6
3.8
0.6
6H
5.8
1.1
6.1
1.4
0.2
1.5
5.8
1.1
6.0
1.9
0.3
2.1
5.4
1.0
5.6
2.1
0.4
2.2
5.0
0.9
8H
7.2
1.3
8.0
1.8
0.3
2.3
7.4
1.3
7.9
2.3
0.4
2.8
6.7
1.3
7.5
2.9
0.5
3.5
3.0
1.1
12H
11.9
3.6
13.5
3.0
0.9
3.5
11.5
3.5
13.0
3.8
1.1
4.3
10.3
3.4
11.5
4.1
1.3
4.6
10.2
3.1
12HT
12.0
3.4
15.0
2.8
0.8
3.6
11.2
3.1
14.5
3.3
0.9
4.4
11.1
2.8
13.1
3.9
1.0
4.7
10.7
2.5
7
15H
14.5
3.2
16.3
3.5
0.8
4.1
14.0
3.1
15.9
4.3
0.9
5.0
11.7
2.8
12.4
4.1
1.0
4.7
10.0
2.5
15HT
15.0
3.4
17.4
3.6
0.8
4.2
14.5
3.1
16.5
4.4
0.9
5.1
12.0
2.8
15.3
4.2
1.0
5.8
12.8
2.5
17HT
16.9
3.3
21.3
4.0
0.8
6.9
15.8
4.4
20.0
4.6
1.5
7.9
15.0
4.1
17.7
5.5
1.9
6.6
14.4
3.8
21HT
20.7
7.4
21.7
5.0
1.7
7.3
19.5
6.6
21.1
5.9
2.0
8.5
18.7
6.2
22.8
6.9
2.3
8.9
4H
4.5
0.8
5.1
1.0
0.2
1.2
4.2
0.8
4.8
1.2
0.2
1.5
4.4
0.7
4.5
1.5
0.2
1.6
4.1
0.7
6H
6.3
1.2
6.7
1.4
0.2
1.5
6.2
1.1
6.5
2.0
0.3
2.1
6.0
1.1
6.1
2.2
0.4
2.3
5.3
1.0
8H
7.8
1.5
8.7
1.8
0.3
2.3
8.0
1.4
8.6
2.3
0.4
2.8
7.3
1.4
8.1
2.5
0.4
3.0
3.3
1.2
12H
12.9
3.9
14.6
3.0
0.9
3.4
12.3
3.7
13.9
3.8
1.1
4.4
11.5
3.6
12.4
4.4
1.3
4.7
10.8
3.3
12HT
12.9
3.7
16.1
2.7
0.8
3.5
12.0
3.3
15.9
3.5
0.9
4.7
11.9
3.0
14.3
3.9
1.0
4.9
11.6
2.6
10
15H
15.7
3.5
17.5
3.5
0.8
4.0
15.1
3.3
17.1
4.4
0.9
5.1
12.7
3.0
13.4
4.3
1.0
4.8
11.3
2.6
15HT
16.1
3.7
18.7
3.5
0.8
4.1
15.9
3.3
18.1
4.7
0.9
5.5
13.1
3.0
16.8
4.3
1.0
6.0
13.7
2.6
17HT
16.9
3.7
25.3
4.1
0.7
7.4
15.9
4.9
25.0
4.7
1.2
8.7
15.0
4.6
18.3
5.4
1.6
6.6
14.4
4.6
21HT
22.4
8.6
32.1
5.0
2.2
8.8
21.3
7.6
30.9
5.9
2.6
10.2 20.1
7.1
24.4
6.8
3.2
8.9
4H
5.6
1.1
6.5
1.0
0.2
1.2
5.2
1.0
6.0
1.3
0.2
1.5
5.4
1.0
5.6
1.6
0.3
1.6
4.9
0.9
6H
8.0
1.5
8.4
1.3
0.2
1.5
7.7
1.4
8.2
2.0
0.3
2.2
6.9
1.4
7.1
2.1
0.4
2.2
6.1
1.2
8H
9.9
1.8
11.0
1.8
0.3
2.3
10.0
1.8
10.8
2.3
0.4
2.8
9.1
1.7
10.1
2.6
0.5
3.1
4.0
1.4
12H
16.3
4.9
18.5
2.9
0.9
3.3
15.2
4.6
17.2
4.0
1.2
4.6
13.9
4.4
14.6
4.5
1.4
4.7
11.1
4.0
20
12HT
16.1
4.7
20.2
2.7
0.8
3.4
15.0
4.1
18.9
3.9
1.0
4.7
14.9
3.7
17.1
4.2
1.0
4.9
14.2
3.2
15H
19.9
4.4
21.7
3.4
0.7
3.7
18.6
4.1
20.4
4.6
1.0
5.1
15.0
3.7
15.8
4.3
1.0
4.8
11.9
3.1
15HT
20.2
4.7
23.5
3.4
0.8
4.0
18.9
4.1
21.6
4.7
1.0
5.5
15.7
3.7
20.0
4.4
1.0
6.0
16.0
3.1
17HT
21HT
PI Power input, kW (power input values include the compressor, fans and control)
HC Heating capacity, kW
Heating floor
35
60
Max. Nom.
3.2
1.4
4.0
1.9
2.9
1.3
8.9
4.3
8.6
3.5
9.0
3.8
9.7
4.3
11.1
5.6
4.2
1.5
5.1
2.2
3.7
1.4
11.0
4.9
12.9
4.0
11.2
4.6
14.5
4.9
15.0
5.5
4.4
1.6
5.3
2.2
4.0
1.4
11.3
4.9
13.8
4.1
11.3
4.9
16.0
5.0
15.3
5.7
5.4
1.6
6.1
2.2
4.8
1.5
11.6
4.3
16.4
4.2
11.9
4.8
19.0
4.9
-
PI kW
Min. Max.
0.2
1.5
0.3
2.1
0.4
1.5
1.3
4.9
1.0
4.3
1.1
4.7
1.0
5.0
1.9
5.8
0.2
1.7
0.4
2.3
0.5
1.8
1.5
5.3
0.9
4.9
1.1
5.4
0.9
5.7
2.1
5.8
0.2
1.7
0.4
2.2
0.5
1.8
1.5
5.1
0.9
5.0
1.1
4.9
0.9
5.9
1.7
6.2
0.3
1.8
0.4
2.2
0.5
1.8
1.5
4.5
0.9
4.9
1.1
4.8
0.9
5.9
-
Condenser entering/leaving water temperature difference: 5 K (for leaving water temperatures below 50°C)
Condenser fluid: water
Fouling factor: 0.000018 m 2 K/W
Performances in accordance with EN14511-3:2011.
20
A leader in Cooling, Heating and Indoor Air Quality
3-Year
Warranty
Available
www.cdlweb.info
email: sales@cooldesignsltd.co.uk
tel.: 0191 549 6964
•
•
•
•
•
•
Heating only (optional GeoCooling).
GEOCIAT Power
Water outlet temperature up to 60°C.
Water-to-water heat pump
COP certified up to 4.24.
Extra low noise level.
Two class A variable-speed accelerator pumps and 12 l expansion vessels.
Units supplied with flexible connections and filter valve kit as standard.
GEOCIAT Power
Underfloor heating 30/35°C*
Heating to 0/-3°C
kW
COP
SCOP
Energy class
Heating to 10/7°C
kW
COP
Comfort unit 40/45°C*
Heating to 0/-3°C
kW
COP
Radiators 47/55°C*
Heating to 0/-3°C
kW
COP
SCOP
Energy class
Sound power*
dB(A)
Power supply
V-ph-Hz
Part Number
Price
£
50H
50HT
65HT
90HT
120HT
12.48
4.15
4.34
A++
16.50
5.31
12.16
4.24
4.41
A++
16.39
5.42
15.80
4.21
4.44
A++
21.13
5.32
21.44
4.06
4.24
A++
27.64
5.25
27.35
4.24
4.31
A++
37.62
5.43
12.02
3.31
11.55
3.33
15.08
3.30
20.59
3.24
25.95
3.32
11.90
2.95
3.31
A+
54
230-1-50
7402076
11.80
3.03
3.30
A+
54
14.80
2.93
3.29
A+
52
20.50
2.89
3.21
A+
53
25.80
2.95
3.27
A+
55
7402079
7402080
7402081
7402083
8,210
7,900
8,161
9,538
11,083
400-3-50
* Following conditions NFPAC. Certified data NFPAC under No. NF414-1278.
Accessories
Description
Manual valve kit (2 x required)
Filling kit
GeoCooling kit
200 l 8-nozzle mixing tank
400 l 8-nozzle mixing tank
9 kW aux heater kit to be integrated in the 8-nozzle mixing tanks
5 kW (single phase) loop heater
9 kW (three phase) loop heater
2-zone kit (accelerator pump, 3-way valve, thermometers, HomeConnect
expansion board, wireless IO Homecontrol sensor)
HomeConnect expansion board
Pool heating kit (sensor + 3-way valves)
UFHC limiter thermostat (60°C)
300 l domestic hot water tank (sensor and 3-way valve)
Outdoor sensor with radio signal (to replace the wired outdoor sensor)
Offset sensor (10 m)
Sectional heat exchanger ITEX AGEO (water-to-water operation)
Sizes 50H/HT-65HT
7110726
7013877
7438199
7328747
7328748
7221389
7148641
7438198
Price, £
73
92
1,453
713
957
374
743
1,318
Sizes 90HT-120HT
7110727
7111810
7438200
7328748
7221389
7148642
7438198
Price, £
88
109
1,563
957
374
902
1,318
7438336
7111122
7274278
7411502
7262090
7438175
7268481
304
435
68
1,602
92
147
824
7438336
7111122
7274278
7262090
7438175
7268481
304
435
68
92
147
824
21
A leader in Cooling, Heating and Indoor Air Quality
www.cdlweb.info
email: sales@cooldesignsltd.co.uk
tel.: 0191 549 6964
GEOCIAT Power performance tables
Heating floor
GEOCIAT
Leaving chilled water
30
35
Power
temp., °C
PI kW
HC kW
PI kW
HC kW
50H
2.7
11.4
3.0
11.2
50HT
2.6
11.2
2.9
11.1
-6
65HT
3.4
14.4
3.7
14.2
90HT
4.7
19.6
5.2
19.2
120HT
5.7
24.7
6.3
24.3
50H
2.7
12.1
3.0
11.9
50HT
2.6
11.9
2.9
11.8
-4
65HT
3.4
15.3
3.7
15.1
90HT
4.8
20.8
5.3
20.5
120HT
5.8
26.2
6.4
25.9
50H
2.7
12.8
3.0
12.6
50HT
2.6
12.7
2.9
12.5
40% glycol
-2
65HT
3.5
16.3
3.8
16.0
solution
90HT
4.8
22.2
5.3
21.7
120HT
5.9
27.9
6.4
27.4
50H
2.8
13.6
3.1
13.4
50HT
2.7
13.5
2.9
13.3
0
65HT
3.5
17.3
3.9
17.0
90HT
4.9
23.6
5.4
23.2
120HT
6.0
29.6
6.5
29.2
50H
2.8
14.5
3.1
14.3
50HT
2.7
14.4
3.0
14.1
2
65HT
3.6
18.4
3.9
18.0
90HT
5.0
25.1
5.4
24.6
30.9
120HT
6.0
31.6
6.6
50H
2.8
16.2
3.1
15.9
50HT
2.7
16.1
3.0
15.8
5
65HT
3.5
20.6
3.8
20.1
90HT
4.9
27.9
5.3
27.2
120HT
6.1
35.8
6.6
34.9
50H
2.8
16.7
3.1
16.3
50HT
2.7
16.7
3.0
16.2
6
65HT
3.5
21.2
3.8
20.7
90HT
4.9
28.8
5.4
28.1
120HT
6.1
36.9
6.7
35.9
50H
2.8
17.2
3.1
16.8
50HT
2.7
17.1
3.0
16.7
7
65HT
3.5
21.9
3.9
21.2
90HT
5.0
29.7
5.4
28.8
120HT
6.2
38.0
6.7
36.9
50H
2.8
17.8
3.1
17.3
50HT
2.7
17.7
3.0
17.2
8
65HT
3.5
22.6
3.9
21.8
90HT
5.0
30.6
5.4
29.7
120HT
6.2
39.1
6.8
38.0
50H
2.9
18.8
3.2
18.4
50HT
2.8
18.7
3.1
18.2
10
65HT
3.5
23.9
3.9
23.1
Pure water
90HT
5.1
32.5
5.5
31.5
120HT
6.3
41.4
6.9
40.3
50H
2.9
20.0
3.2
19.4
2.8
19.9
3.1
19.2
50HT
12
65HT
3.5
25.4
3.9
24.4
90HT
5.1
34.6
5.7
33.2
120HT
6.4
44.0
7.0
42.5
50H
3.0
21.8
3.3
21.1
50HT
2.9
21.6
3.2
20.9
15
65HT
3.5
27.7
3.9
26.5
90HT
5.4
37.7
5.9
36.1
120HT
6.7
47.8
7.1
46.2
50H
3.1
23.8
3.3
23.1
50HT
2.9
23.6
3.2
22.8
65HT
3.5
30.3
3.9
28.9
18
5.5
41.3
6.0
39.4
90HT
120HT
6.9
52.1
7.3
50.4
50H
3.1
25.2
3.4
24.4
50HT
3.0
25.0
3.3
24.1
65HT
3.6
32.1
4.0
30.6
20
5.6
43.8
6.2
41.7
90HT
120HT
7.1
55.2
7.5
53.4
PI Power input, kW (power input values include the compressor, fans and control)
Leaving hot water temperature, °C
Comfort unit
40
45
50
PI kW
HC kW
PI kW
HC kW
PI kW
HC kW
3.3
11.1
3.6
10.8
4.0
10.7
3.2
10.9
3.4
10.7
3.8
10.5
4.0
13.9
4.5
13.6
4.9
13.0
5.8
18.9
6.3
18.6
7.0
18.3
7.0
23.9
7.7
23.5
8.6
23.1
3.4
11.7
3.6
11.5
4.0
11.3
3.2
11.6
3.5
11.3
3.8
11.1
4.1
14.8
4.5
14.4
5.0
13.9
5.8
20.1
6.3
19.7
7.1
19.4
7.0
25.4
7.8
24.9
8.7
24.4
3.4
12.4
3.7
12.2
4.0
11.9
3.2
12.3
3.5
12.0
3.9
11.8
4.2
15.7
4.6
15.3
5.0
14.8
5.9
21.3
6.4
12.0
7.1
20.5
7.1
26.9
7.9
26.4
8.8
25.8
3.4
13.2
3.7
12.9
4.1
12.6
3.2
13.0
3.5
12.7
3.9
12.5
4.2
16.6
4.7
16.3
5.1
15.8
5.9
22.6
6.4
22.3
7.1
21.7
7.2
28.4
8.0
28.0
8.9
27.4
3.4
14.0
3.7
13.6
4.1
13.3
3.3
13.9
3.6
13.4
4.0
13.1
4.3
17.7
4.7
17.2
5.2
16.7
6.0
24.1
6.4
23.5
7.2
22.9
7.3
30.2
8.1
29.5
8.9
28.8
3.3
15.6
3.7
15.1
4.1
14.7
3.3
15.4
3.7
15.0
4.1
14.6
4.3
19.5
4.7
19.0
5.2
18.4
5.9
26.6
6.6
25.8
7.3
25.1
7.3
34.0
8.1
33.1
9.0
32.2
3.4
15.9
3.7
15.5
4.2
15.1
3.4
15.7
3.7
15.4
4.1
15.0
4.4
19.9
4.8
19.5
5.2
18.9
6.1
27.1
6.6
26.6
7.4
25.8
7.5
34.7
8.1
34.0
9.1
33.0
3.5
16.4
3.8
16.0
4.2
15.5
3.4
16.1
3.7
15.9
4.1
15.4
4.4
20.4
4.8
20.0
5.2
19.3
6.1
27.9
6.7
27.3
7.4
26.5
7.6
35.7
8.2
35.0
9.1
33.9
3.5
16.9
3.8
16.4
4.2
15.9
3.5
16.6
3.7
16.3
4.1
15.8
4.4
21.0
4.8
20.5
5.2
19.8
6.2
28.7
6.7
28.0
7.4
27.2
7.7
36.8
8.3
35.8
9.2
34.8
3.5
17.8
3.9
17.1
4.2
16.8
3.5
17.6
3.9
17.0
4.2
16.7
4.4
22.2
5.0
21.4
5.3
20.9
6.2
30.4
7.0
29.3
7.5
28.6
7.7
38.9
8.7
37.4
9.3
36.6
3.8
18.3
4.1
17.8
3.5
18.8
3.5
18.6
3.8
18.2
4.1
17.7
4.4
23.4
4.8
22.8
5.2
22.1
6.3
32.1
6.8
31.3
7.4
30.4
7.8
41.1
8.4
40.0
9.2
38.8
3.6
20.5
3.9
19.8
4.3
19.1
3.5
20.3
3.8
19.7
4.3
19.0
4.4
25.5
4.9
24.6
5.4
23.7
6.4
35.0
7.0
33.9
7.7
32.7
7.8
44.8
8.6
43.3
9.6
41.7
3.7
22.3
4.0
21.5
4.4
20.7
3.6
22.1
3.9
21.4
4.3
20.6
4.4
27.7
4.9
26.6
5.4
25.6
6.6
38.1
7.2
36.7
7.8
35.4
8.0
48.7
8.7
46.9
9.7
45.1
3.7
23.5
4.0
22.7
4.4
21.9
3.6
23.4
4.0
22.6
4.4
21.8
4.4
29.2
4.9
28.1
5.4
27.0
6.6
40.3
7.3
38.8
7.9
37.4
8.1
51.6
8.8
49.6
9.7
47.7
HC
Heating capacity, kW
Radiator
55
PI kW
HC kW
4.5
12.3
4.3
12.2
5.8
15.4
8.0
21.0
9.9
26.7
4.5
13.0
4.4
12.9
5.9
16.4
8.0
22.1
9.9
28.1
4.6
14.3
4.5
14.2
5.7
18.1
8.0
24.6
10.0
31.2
4.6
14.7
4.6
14.6
5.7
18.6
8.1
25.3
10.1
32.1
4.6
15.1
4.6
14.9
5.7
19.0
8.1
26.0
10.1
32.8
4.7
15.5
4.6
15.4
5.8
19.6
8.1
26.7
10.2
33.7
4.7
16.3
4.6
16.2
5.8
20.6
8.2
28.2
10.3
35.4
4.7
17.1
4.7
17.0
5.8
21.6
8.3
29.7
10.4
37.2
4.7
18.5
4.7
18.4
5.9
23.3
8.4
32.4
10.6
40.3
4.8
20.0
4.7
19.9
5.9
25.1
8.5
35.1
10.7
43.5
4.8
21.0
4.8
20.9
5.9
26.4
8.6
37.1
10.8
45.7
PI kW
5.1
5.0
6.2
9.0
11.2
5.1
5.0
6.2
9.0
11.2
5.1
5.0
6.2
9.0
11.3
5.1
5.1
6.3
9.1
11.3
5.2
5.1
6.3
9.1
11.4
5.2
5.1
6.3
9.2
11.5
5.2
5.2
6.4
9.3
11.6
5.3
5.2
6.4
9.4
11.8
5.3
5.2
6.4
9.4
11.9
60
HC kW
13.9
13.8
17.4
23.8
30.3
14.3
14.1
17.8
24.4
31.0
14.6
14.5
18.2
25.0
31.8
15.0
14.9
18.7
25.6
32.5
15.8
15.6
19.7
26.9
34.2
16.6
16.4
20.7
28.3
35.9
17.9
17.8
22.3
30.5
38.7
19.3
19.2
24.1
32.9
41.7
20.3
20.2
25.3
34.5
43.8
22
A leader in Cooling, Heating and Indoor Air Quality
3-Year
Warranty
Available
www.cdlweb.info
email: sales@cooldesignsltd.co.uk
tel.: 0191 549 6964
Comprehensive packaged unit.
GEOCIAT Access
GeoCooling as standard.
Geothermal heat pump
R410A scroll compressor.
Brazed plate heat exchanger.
Hydraulic module with class A variable-speed accelerator pumps and
expansion vessel.
• Domestic hot water valve integrated as standard (300 l tank optional).
• HomeConnect control with remote control station.
• Units supplied with flexible connections and filter valve kit as standard.
•
•
•
•
•
GEOCIAT Access
Underfloor heating 30/35°C*
Heating to 0/-3°C
COP
SCOP
Energy class
Fan coil unit 40/45°C*
Heating to 0/-3°C
COP
Radiators 47/55°C*
Heating to 0/-3°C
COP
SCOP
Energy class
Maximum leaving water temperature
Sound power*
Power supply
Double Service hot water supply from 300 l tank**
Tank capacity
Withdrawing cycle
Hot water temperature
COP
Part Number
Price
18H
kW
4.74
4.11
4.35
A++
kW
4.48
3.23
kW
4.19
2.60
3.14
A+
62
53
230-1-50
°C
dB(A)
V-ph-Hz
l
°C
300
XL
54.2
2.72
7368964
£
5,603
* Following conditions NFPAC. Certified data NFPAC under No. NF414-11385E/1068.
** Following conditions NFPAC Double Service. Certified data NFPAC under No. NF414-1386E/1069.
23
A leader in Cooling, Heating and Indoor Air Quality
www.cdlweb.info
email: sales@cooldesignsltd.co.uk
tel.: 0191 549 6964
GEOCIAT Access accessories
Accessories
Description
1” filling kit* (2 x required)
1” manual valve kit* (2 x required)
Kit for 4 kW GEOCIAT Access
HomeConnect expansion board
2-zone kit**
Hygrometric probe for PCR**
Offset sensor (10 m)
Outdoor sensor with radio signal
Floor limit thermostat (60°C)
* Primary and secondary kit supplied
** Options controlled by one HomeConnect expansion board
Price, £
81
92
420
285
1,091
191
147
92
68
Part Number
7013876
7110700
7396343
7371947
7367399
7076818
7438175
7262090
7274278
GEOCIAT Access performance tables
GEOCIAT
Access
Leaving chilled water
temperature, °C
-6
-4
-3
40% glycol
solution
-2
0
2
5
18H
6
7
8
Pure water
10
12
15
18
PI Power input, kW (power input
HC Heating capacity, kW
30
35
40
PI kW
HC kW
PI kW
HC kW
PI kW
HC kW
1.00
4.21
1.11
4.20
1.22
4.21
1.01
4.56
1.11
4.51
1.23
4.44
1.01
4.73
1.12
4.66
1.24
4.60
1.02
4.89
1.12
4.85
1.24
4.74
1.02
5.23
1.13
5.12
1.25
5.01
1.02
5.55
1.14
5.43
1.27
5.31
0.98
6.10
1.11
6.00
1.24
5.84
0.98
6.35
1.11
6.16
1.24
6.02
0.98
6.52
1.11
6.35
1.25
6.19
0.98
6.70
1.11
6.54
1.25
6.36
0.97
7.08
1.11
6.91
1.25
6.71
0.97
7.49
1.10
7.28
1.25
7.07
0.95
8.14
1.10
7.90
1.25
7.66
0.94
8.68
1.09
8.40
1.25
8.08
values include the compressor, fans and control)
45
PI kW
1.34
1.36
1.37
1.37
1.39
4.41
1.37
1.38
1.39
1.39
1.40
1.41
1.42
1.42
50
HC kW
4.13
4.38
4.50
4.64
4.93
5.21
5.69
5.84
6.02
6.21
6.53
6.89
7.40
7.79
PI kW
1.47
1.48
1.50
1.51
1.53
1.54
1.54
1.55
1.55
1.55
1.56
1.58
1.58
1.60
55
HC kW
4.05
4.30
4.43
4.56
4.81
5.08
5.54
5.70
5.84
6.00
6.31
6.63
7.15
7.49
PI kW
1.62
1.63
1.64
1.66
1.68
1.71
1.71
1.72
1.72
1.73
1.74
1.75
1.78
1.78
60
HC kW
3.99
4.23
4.34
4.46
4.71
4.95
5.38
5.54
5.67
5.79
6.11
6.42
6.90
7.19
PI kW
1.77
1.79
1.80
1.81
1.84
1.87
1.89
1.91
1.92
1.92
1.94
1.96
1.98
1.99
62
HC kW
3.91
4.14
4.26
4.37
4.59
4.84
5.24
5.34
5.47
5.60
5.89
6.17
6.63
6.87
PI kW
1.84
1.83
1.87
1.88
1.92
1.95
1.97
1.98
1.99
2.00
2.03
2.04
2.08
2.08
HC kW
3.89
4.09
4.22
4.33
4.55
4.79
5.16
5.27
5.41
5.54
5.80
6.08
6.52
6.76
24
A leader in Cooling, Heating and Indoor Air Quality
Extended
Warranty
Available
www.cdlweb.info
email: sales@cooldesignsltd.co.uk
tel.: 0191 549 6964
•
•
•
•
•
•
AQUACIAT Caleo
Air-to-water heat pump
Water outlet temperature 65°C at -12°C.
Winter operation (-20°C).
High energy efficiency (COP).
Compact and quiet.
Scroll compressors.
Self-adjusting electronic control.
AQUACIAT Caleo
Net heating capacity*
COP*
SCOP
P-rated/Energy class
Heating capacity**
COP**
SCOP
P-rated/Energy glass
Refrigerant charge (R407C)
Expansion tank capacity
Minimum system water volume
Max. system capacity***
- pure water at 65°C/90°C
- 40% glycol/water mix at 65°C/90°C
No. of fan speeds/available pressure
Minimum/maximum water flow rate
Operating limits (winter/summer)
Maximum leaving water temperature
Sound pressure level (high temperature)
System current
Starting current (with SoftStart)
Part Number
Price
kW
kW
kW
kW
kg
l
l
l
kPa
m3/h
°C
°C
dB(A)
A
A
£
80Z
24.8
3.63
2.97
14.5/A
25.9
2.63
2.57
14.8/A+
7.2
18
227
100Z
34.7
3.75
2.32
19.6/A+
34.7
2.62
2.77
20.9/A+
11.5
18
319
120Z
40.8
3.92
3.31
24.1/A+
43.1
2.71
2.82
25.7/A+
18.0
18
374
150Z
47.3
3.83
3.34
28.4/A+
48.7
2.81
2.83
30.1/A+
18.0
18
434
450/250
275/185
1/145
3.2/7.6
-20/45
65
77
22.2
99 (59)
7223410
450/250
275/185
1/115
3.9/8.5
-20/45
65
77
27.1
127 (76)
7223409
450/250
275/185
1/140
4.4/12.2
-20/45
65
77
31.0
167 (100)
7223408
450/250
275/185
1/135
4.9/13.0
-20/45
65
77
36.3
198 (119)
7223406
12,955
15,563
16,993
18,928
* Heating capacities in high performance version at the unit outlet, based on hot water outlet at 35°C and outside air 7°C DB 86% RH.
** Heating capacities in high performance version at the unit outlet, based on hot water outlet at 45°C and outside air 7°C DB 86% RH.
*** For temperatures outside of this, an additional expansion tank is required.
Accessories
Description
1-1/2” flexible customer kit
SoftStart kit
Phase monitor kit (reversal, loss, over- and undervoltage)
1-1/2” filling kit*
Electrical auxiliary unit by 9 kW loop heater supplied separately
Electrical auxiliary unit by 15 kW loop heater supplied separately
Hydraulic control kit (pressure gauges, control & shut-off valve)
200 litre 8-nozzle mixing tank
400 litre 8-nozzle mixing tank
9 kW electrical auxiliary kit to be integrated into the 200 or 400 litre 8-nozzle mixing tank
Pool heating kit with motorised 3-way valves
DHW heating kit (2 x 300 litre tanks in parallel) and motorised 3-way valves
Safety hot water thermostat kit (60°C)
Frost protection
Part Number
7187605
7272062
7081668
7111810
7148642
7272405
3911008
7328747
7328748
7221389
7111122
2 x 7385910 + 7411357
7101578
7090373
Price, £
147
290/650 (150Z)
201
101
836
994
1,264
661
887
347
403
2,969
54
200
25
A leader in Cooling, Heating and Indoor Air Quality
www.cdlweb.info
email: sales@cooldesignsltd.co.uk
tel.: 0191 549 6964
AQUACIAT Caleo performance tables
Heating capacities
AQUACIAT
Caleo
Outdoor air
temp., °C
Leaving hot water temperature, °C
40
45
50
HC kW PI kW HC kW PI kW HC kW PI kW HC kW PI kW HC kW PI kW HC kW PI kW
-20
9.7
4.9
9.9
5.1
10.1
5.6
10.2
5.9
10.5
6.5
10.2
6.9
-15
11.6
5.1
11.8
5.4
12.2
5.8
12.2
6.1
12.3
6.7
12.9
7.3
-10
13.4
5.3
13.8
5.6
14.2
6.0
14.5
6.4
14.7
6.9
14.9
7.6
-7
14.5
5.4
14.9
5.7
15.4
6.2
15.7
6.6
15.9
7.1
16.1
7.8
-5
15.7
5.5
16.1
5.8
16.5
6.2
17.0
6.8
17.2
7.3
17.7
8.0
0
18.5
5.7
19.1
6.0
19.2
6.5
19.6
7.0
20.3
7.6
20.7
8.4
5
22.3
5.8
22.9
6.1
23.8
6.7
24.2
7.2
24.6
8.0
24.9
8.8
7
23.1
5.8
23.9
6.1
24.7
6.7
24.8
7.3
25.1
8.1
25.9
9.1
80Z
10
25.1
5.9
25.3
6.2
25.5
6.8
26.6
7.4
27.2
8.2
27.1
9.2
15
27.7
5.9
27.9
6.3
28.6
6.9
28.9
7.6
29.8
8.5
30.3
9.4
20
29.5
6.0
29.7
6.4
30.7
6.9
31.0
7.6
31.5
8.6
31.7
9.5
25
30.6
6.0
31.5
6.5
32.1
7.0
32.9
7.8
33.5
8.7
33.8
9.6
30
31.8
6.2
32.6
6.6
33.8
7.2
34.6
7.8
36.0
8.8
36.3
9.8
35
33.2
6.3
34.6
6.8
35.9
7.5
37.6
8.0
38.7
9.1
40.0
10.1
40
37.5
7.7
38.5
8.2
40.2
9.4
41.0
10.3
45
38.5
7.9
40.2
8.4
41.6
9.6
42.6
10.5
-20
13.9
6.2
14.0
6.7
14.1
7.2
14.7
7.7
14.9
8.4
15.1
9.4
-15
16.6
6.5
16.8
7.0
17.0
7.4
17.4
8.0
17.7
8.7
18.0
9.7
-10
19.0
6.7
19.4
7.2
19.6
7.7
20.0
8.4
20.3
9.1
20.2
10.0
21.1
7.9
21.4
8.6
22.1
9.4
22.5
10.3
-7
20.3
6.9
20.6
7.3
-5
22.2
7.0
22.5
7.5
22.7
8.1
22.9
8.8
23.1
9.6
23.7
10.6
0
26.0
7.2
26.4
7.8
26.7
8.5
26.8
9.2
27.2
10.0
27.3
11.2
5
32.2
7.5
33.1
8.1
33.2
8.9
33.6
9.6
33.9
10.5
34.2
11.7
7
33.7
7.6
34.2
8.3
34.5
9.0
34.7
9.8
35.5
10.7
35.7
11.8
100Z
10
38.5
7.8
38.6
8.5
38.9
9.2
39.1
10.1
39.4
11.0
39.6
12.2
15
41.4
8.0
42.1
8.6
42.2
9.5
42.3
10.4
43.0
11.4
43.1
12.5
20
44.1
8.2
45.1
8.7
45.9
9.6
46.2
10.5
46.4
11.5
46.6
12.6
25
45.7
8.3
47.0
8.9
47.9
9.8
48.2
10.6
48.4
11.6
48.5
12.7
30
47.4
8.5
48.7
9.2
49.7
10.1
50.6
11.0
51.5
11.9
51.6
13.0
35
49.6
8.7
51.7
9.5
52.9
10.4
53.7
11.2
54.9
12.3
55.6
13.4
40
54.2
10.7
55.0
11.5
56.3
12.6
57.2
13.7
45
55.8
11.1
56.6
11.8
57.8
12.8
58.4
14.0
-20
14.7
7.2
14.9
7.6
15.3
8.2
15.5
8.8
15.8
9.9
15.7
11.0
-15
19.0
7.7
19.2
8.3
19.5
8.7
20.0
9.5
20.3
10.5
20.6
11.5
-10
21.6
8.0
23.0
8.6
23.7
9.2
24.0
10.1
24.1
11.0
24.2
12.0
-7
25.0
8.2
26.2
8.7
26.7
9.5
26.9
10.3
27.0
11.5
27.0
12.3
-5
26.9
8.3
28.0
8.8
28.9
9.7
29.3
10.6
29.4
11.8
30.2
12.8
0
29.9
8.5
31.7
8.9
32.7
9.9
33.1
11.0
33.3
12.3
33.4
13.4
5
34.7
8.6
39.1
9.2
40.1
10.1
39.4
11.4
40.6
12.7
40.9
14.1
7
37.8
8.7
40.4
9.3
40.6
10.2
42.1
11.6
42.6
12.9
43.3
14.3
120Z
42.8
10.3
43.6
11.8
45.3
13.1
45.5
14.6
10
40.2
8.8
42.1
9.3
15
42.9
8.9
44.8
9.5
45.5
10.5
46.8
11.9
48.4
13.3
49.4
14.9
20
44.7
9.1
46.8
9.6
48.0
10.7
49.4
12.0
51.0
13.4
51.7
14.9
25
48.0
9.3
49.5
9.8
51.1
10.8
51.7
12.1
52.6
13.5
54.0
15.0
30
51.0
9.5
51.7
10.0
53.0
11.0
53.9
12.3
55.4
13.6
56.6
15.1
35
53.7
9.8
54.5
10.2
56.3
11.4
57.9
12.6
59.5
13.8
60.9
15.2
40
58.1
11.9
59.3
12.9
61.5
14.0
62.8
15.5
45
59.8
12.5
61.2
13.1
63.3
14.1
65.8
15.6
-20
17.0
8.6
17.8
9.1
18.8
9.5
19.7
10.1
19.9
10.7
19.7
11.6
-15
20.3
8.8
21.6
9.4
22.4
10.0
22.7
10.5
23.6
11.2
25.0
12.6
-10
25.1
9.2
26.5
9.7
27.9
10.6
28.0
11.3
28.4
12.2
28.4
13.0
-7
29.1
9.5
29.7
10.0
30.0
10.9
30.4
11.6
30.8
12.5
31.1
13.4
-5
31.8
9.7
32.2
10.3
32.4
11.2
32.5
12.0
32.7
12.9
33.1
13.9
0
36.0
9.9
37.5
10.8
37.7
11.6
38.2
12.6
38.6
13.7
38.8
14.7
5
42.1
10.0
43.8
11.0
44.8
12.1
45.5
13.2
46.0
14.2
46.6
15.5
7
46.5
10.1
46.8
11.1
47.1
12.2
48.4
13.4
48.8
14.6
49.3
15.7
150Z
10
50.7
10.1
51.5
11.2
52.9
12.4
53.3
13.7
53.5
14.9
53.8
16.1
15
54.8
10.2
55.9
11.3
57.1
12.6
57.6
13.9
57.8
15.2
58.6
16.5
20
56.6
10.3
57.9
11.4
59.2
12.7
59.6
14.0
59.9
15.3
60.2
16.7
25
58.1
10.5
59.0
11.5
60.8
12.7
61.7
14.1
61.7
15.4
61.5
16.8
30
61.9
10.7
63.0
11.6
63.5
12.8
63.9
14.2
64.3
15.5
64.5
17.0
66.6
13.0
68.3
14.7
68.6
15.7
68.9
17.4
35
64.4
11.2
65.5
12.1
40
68.5
13.4
71.2
15.1
72.4
16.2
73.0
18.0
45
70.9
13.9
73.8
15.5
75.1
16.9
76.1
18.5
PI Power input, kW (power input values include the compressor and fan, and defrost cycles)
HC Heating capacity, kW
25
30
35
55
HC kW
13.0
14.8
15.8
17.4
20.5
24.6
25.7
27.1
30.5
32.2
33.9
36.2
39.9
41.2
42.7
17.8
20.1
22.0
23.5
26.9
33.0
34.5
37.9
41.4
44.9
47.1
50.5
54.9
56.6
58.0
20.5
24.0
26.9
29.6
33.5
40.7
43.0
45.2
49.2
51.5
53.8
56.4
60.5
63.0
66.2
24.7
27.3
30.2
32.9
38.2
46.0
48.5
53.9
58.2
59.7
61.5
63.9
69.1
73.1
75.9
60
PI kW
8.1
8.4
8.6
8.8
9.2
9.6
9.7
9.9
10.4
10.6
10.8
11.0
11.2
11.5
11.9
10.7
11.1
11.5
11.9
12.2
12.8
13.0
13.3
13.7
13.8
14.0
14.3
14.8
15.1
15.6
12.8
13.5
13.8
14.1
14.8
15.4
15.7
16.0
16.3
16.4
16.6
16.7
16.9
17.3
17.6
13.8
14.6
15.1
15.5
16.3
16.9
17.2
17.5
18.0
18.2
18.4
18.6
19.2
19.9
20.7
HC kW
12.3
14.5
15.7
17.0
19.7
23.7
25.1
26.2
30.0
31.7
33.3
35.7
39.8
40.8
41.8
17.4
19.6
21.6
23.0
26.4
32.5
33.4
36.3
39.5
42.3
45.2
48.8
54.0
55.5
56.7
20.0
23.5
25.6
28.9
32.8
40.8
44.0
45.0
49.0
51.3
53.3
55.8
60.1
63.3
66.5
24.0
27.2
29.9
32.6
37.3
45.7
48.3
52.1
57.0
58.6
60.2
62.5
66.7
72.1
75.8
65
PI kW
8.8
9.3
9.5
9.7
10.1
10.6
10.8
11.0
11.4
11.5
11.7
12.2
12.6
12.9
13.1
11.8
12.4
12.7
12.9
13.5
14.0
14.2
14.6
14.9
15.0
15.1
15.4
16.1
16.5
16.9
14.2
14.7
15.0
15.3
15.7
16.5
16.9
17.2
17.5
17.7
17.8
18.0
18.3
18.7
19.1
15.5
16.0
16.4
17.1
17.8
18.4
18.8
19.3
19.7
19.9
20.0
20.1
20.4
21.1
22.2
HC kW
13.8
15.2
16.6
19.1
23.0
24.3
25.5
29.2
31.2
32.6
35.1
39.1
39.7
40.5
18.9
21.2
22.4
26.0
30.9
32.8
35.6
38.7
41.8
44.5
48.2
52.8
54.2
55.7
22.7
24.9
28.1
31.8
39.2
43.1
44.2
48.5
50.3
52.4
54.5
59.0
62.2
65.8
26.3
29.1
31.3
36.6
44.7
46.6
50.8
56.6
57.4
58.6
61.8
66.1
70.9
74.4
PI kW
10.1
10.3
10.4
10.8
11.0
11.2
11.4
11.8
12.0
12.1
12.6
13.2
13.5
13.7
13.5
14.0
14.1
14.5
14.7
14.9
15.0
15.3
15.4
15.6
16.2
16.6
17.0
17.4
15.2
15.6
16.3
16.7
17.2
17.4
17.6
17.8
18.0
18.0
18.4
19.0
19.5
20.1
17.8
18.0
18.3
19.0
19.3
19.5
19.9
20.2
20.2
20.3
20.4
20.6
22.3
23.5
Condenser entering/leaving water temperature difference: 5 K
Condenser fluid: water
Fouling factor: 0.00005 m2 K/W
26
A leader in Cooling, Heating and Indoor Air Quality
Extended
Warranty
Available
www.cdlweb.info
email: sales@cooldesignsltd.co.uk
tel.: 0191 549 6964
•
•
•
•
AQUACIAT
Air-cooled liquid chillers
Screwed connection sleeves as standard.
Anti-vibration mounts as standard.
Micro Channel Heat Exchanger (MCHE).
Connect Touch controller as standard.
AQUACIAT chiller model
Nominal capacity*
EER
ESEER
Eurovent class
Sound power**
Sound pressure at 10 m***
Sound power extra low noise option**
Sound pressure at 10 m extra low noise option***
Width x length
Height (with buffer tank)
Weight - standard unit
Compressors
Minimum output
Maximum total air flow
Part Number
Price (chiller only)****
Part Number with AquaPack†
Price (chiller with AquaPack)
AQUACIAT chiller model
Nominal capacity*
EER
ESEER
Eurovent class
Sound power**
Sound pressure at 10 m***
Sound power extra low noise option**
Sound pressure at 10 m extra low noise option***
Width x length
Height (with buffer tank)
Weight - standard unit
Compressors
Minimum output
Maximum total air flow
Part Number
Price (chiller only)****
Part Number with AquaPack†
Price (chiller with AquaPack)
kW
kW/kW
kW/kW
dB(A)
dB(A)
dB(A)
dB(A)
mm
mm
kg
Scroll
%
l/s
£
£
kW
kW/kW
kW/kW
dB(A)
dB(A)
dB(A)
dB(A)
mm
mm
kg
Scroll
%
l/s
£
£
LD0150A
40
2.87
3.75
C
80
49
79
48
2109 x 1090
1440 (2040)
422
2
50
3885
7490506
LD0180A
44
2.76
3.88
C
81
49
80
48
2109 x 1090
1440 (2040)
430
2
50
3883
7490507
LD0200A
51
2.67
3.95
D
81
49
80
48
2109 x 1090
1440 (2040)
436
2
50
3687
7490508
LD0240A
58
2.66
3.8
D
81
49
80
48
2109 x 1090
1440 (2040)
449
2
50
3908
7490509
LD0260A
67
2.72
3.62
C
87
55
80
48
2109 x 1090
1440 (2040)
445
2
50
5013
7490510
LD0300A
79
2.7
3.67
C
87
55
80
48
2109 x 1090
1440 (2040)
463
2
50
5278
7490511
7490506-AP
7490507-AP
7490508-AP
7490509-AP
7490510-AP
7490511-AP
9,564
14,639
10,035
15,110
10,717
15,793
12,504
17,580
13,650
18,725
15,518
20,594
LD0360A
87
2.73
3.91
C
84
52
83
51
2123 x 2270
1440 (2040)
753
3
33
6940
7490512
LD0390A
97
2.73
3.94
C
84
52
83
51
2123 x 2270
1440 (2040)
762
3
33
6936
7490513
LD0450A
114
2.67
3.83
D
84
52
83
51
2123 x 2270
1440 (2040)
771
3
33
7370
7490514
LD0520A
135
2.7
3.68
C
90
58
83
51
2123 x 2270
1440 (2040)
829
2+2
25
10026
7490515
LD0600A
156
2.65
3.87
D
90
58
83
51
2123 x 2270
1440 (2040)
854
2+2
25
10556
7490516
7490512-AP
7490513-AP
7490514-AP
7490515-AP
7490516-AP
17,249
23,315
18,696
24,762
21,150
27,215
23,557
29,691
26,897
33,031
* Cooling mode conditions: water inlet/outlet temperature12°C/7°C, ambient 35°C.
** In dB ref = 10-12 W, ‘A’ weighted. Measured in accordance with ISO 9614-1.
*** In dB ref 20 uPa, ‘A’ weighted. For information, calculated from the sound power level Lw(A).
Declared dual number noise emission values in accordance with ISO 4871 (with an associated uncertainty of ±3 dB(A). Values are guidelines only.
Refer to the unit name plate.
****Standard commissioning not included. Standard day’s commissionin will be charged at £620 per day. Terms apply.
† AquaPack includes: hydronic module116r, expansion tank 293, water buffer tank module 307, exchanger water filter 310A).
27
A leader in Cooling, Heating and Indoor Air Quality
AQUACIAT cooling only accessories
www.cdlweb.info
email: sales@cooldesignsltd.co.uk
tel.: 0191 549 6964
This is a compact and lightweight range of energy-efficient
chillers covering from 40 kW to 160 kW which uses the MCHE
aluminium coil and EEV as standard, with direct start scroll
compressors, EC fans, safety pressure relief valve, sight glass,
head pressure control, crankcase heaters, anti-short cycling,
low water temperature and low water flow protection.
Listed below are all of the available options that can be
purchased and factory fitted.
AQUACIAT chiller model
Accessories - factory fitted
LD0150A
LD0180A
LD0200A
LD0240A
LD0260A
LD0300A
Part
Total price, Total price, Total price, Total price, Total price, Total price,
Number
£
£
£
£
£
£
Extra fan (180 to 240 mmCE available)*
12_1
1,001
1,001
1,001
1,001
1,001
1,001
Extra low noise (1 to 6 dB(A) depending on model)* 15LS_1
437
437
437
437
437
437
Protection grille for condenser coil
23
77
77
77
116
116
116
Soft Start
25
750
750
750
750
750
750
All year -20°C operation*
28_1
931
931
931
931
931
931
Water exchanger frost protection*
42
488
488
488
488
488
488
Exchanger and hydraulic frost protection
42B
669
669
669
669
669
669
Master/slave operation
58
69
69
69
69
69
69
Hydraulic module (fixed-speed single pump) HP
116R
869
869
869
869
869
869
Hydraulic module (fixed-speed dual pump) HP
116S
1,829
1,829
1,829
1,829
1,829
1,829
Hydraulic module (fixed-speed single pump) LP
116T
631
631
631
631
631
631
Hydraulic module (fixed-speed dual pump) LP
116U
1,330
1,330
1,330
1,330
1,330
1,330
Hydraulic module (variable-speed single pump) HP
116V
1,620
1,620
1,620
1,620
1,620
1,620
Hydraulic module (variable-speed dual pump) HP
116W
2,521
2,521
2,521
2,521
2,521
2,521
BACnet over IP
149
285
285
285
285
285
285
MCHE anti-corrosion protect 2 (light corrosion)
262_1
437
437
437
689
689
689
MCHE anti-corrosion protect 4 (harsh corrosion)
263_1
804
804
804
1,137
1,137
1,137
Reinforced ECM filtration for pump VFD
282B
112
112
112
112
112
112
Expansion tank
293
208
208
208
208
208
208
Water buffer tank module
307
3,752
3,752
3,752
3,752
3,752
3,752
Exchanger flexible sleeve connections
309A
403
403
403
403
403
403
Exchanger water filter
310A
247
247
247
247
247
247
Set point adjustment by 4-20 mA signal
311
53
53
53
53
53
53
Free cooling dry management for Opera or Vextra
313
53
53
53
53
53
53
AQUACIAT chiller model
Accessories - factory fitted
Extra fan (180 to 240 mmCE available)*
Extra low noise (1 to 6 dB(A) depending on model)*
Protection grille for condenser coil
Soft Start
All year -20°C operation*
Water exchanger frost protection*
Exchanger and hydraulic frost protection
Master/slave operation
Hydraulic module (fixed-speed single pump) HP
Hydraulic module (fixed-speed dual pump) HP
Hydraulic module (fixed-speed single pump) LP
Hydraulic module (fixed-speed dual pump) LP
Hydraulic module (variable-speed single pump) HP
Hydraulic module (variable-speed dual pump) HP
BACnet over IP
MCHE anti-corrosion protect 2 (light corrosion)
MCHE anti-corrosion protect 4 (harsh corrosion)
Reinforced ECM filtration for pump VFD
Expansion tank
Water buffer tank module
Exchanger flexible sleeve connections
Exchanger water filter
Set point adjustment by 4-20 mA signal
Free cooling dry management for Opera or Vextra
* Not available with some options.
Service & maintenance, Year 1
Service & maintenance, Years 1 & 2
Service & maintenance, Years 1, 2 & 3
Part
Number
12_1
15LS_1
23
25
28_1
42
42B
58
116R
116S
116T
116U
116V
116W
149
262_1
263_1
282B
293
307
309A
310A
311
313
LD0360A
Total price,
£
1,884
668
138
1,102
1,601
579
688
69
874
1,792
640
1,295
1,622
2,483
285
847
1,316
112
286
4,550
403
353
53
53
LD0390A
Total price,
£
1,884
683
138
1,102
1,601
579
688
69
874
1,792
774
1,572
1,622
2,483
285
847
1,316
112
286
4,550
403
353
53
53
1 to 2 systems, total price, £
1,875
3,844
5,911
LD0450A
Total price,
£
1,884
683
152
1,102
1,601
579
688
69
874
1,943
774
1,572
1,794
2,748
285
876
1,607
112
286
4,550
403
353
53
53
LD0520A
Total price,
£
1,884
905
152
1,470
1,521
579
688
69
943
1,943
869
1,790
1,794
2,748
285
876
1,607
112
286
4,550
403
353
53
53
LD0600A
Total price,
£
1,884
905
233
1,470
1,521
579
688
69
943
1,943
869
1,790
1,794
2,748
285
1,378
2,273
112
286
4,550
403
353
53
53
3 to 4 systems, total price, £
3,750
7,688
11,822
Service & maintenance based on 3 x visits per annum
28
A leader in Cooling, Heating and Indoor Air Quality
www.cdlweb.info
email: sales@cooldesignsltd.co.uk
tel.: 0191 549 6964
AQUACIAT liquid chiller performance table
Cooling capacities
AQUACIAT
chiller
LD0150A
LD0180A
LD0200A
LD0240A
LD0260A
LD0300A
LD0360A
LD0390A
LD0450A
LD0520A
LD0600A
Leaving water
temp., °C
5/11
6/12
7/13
8/14
5/11
6/12
7/13
8/14
5/11
6/12
7/13
8/14
5/11
6/12
7/13
8/14
5/11
6/12
7/13
8/14
5/11
6/12
7/13
8/14
5/11
6/12
7/13
8/14
5/11
6/12
7/13
8/14
5/11
6/12
7/13
8/14
5/11
6/12
7/13
8/14
5/11
6/12
7/13
8/14
25
41
42
43.5
44.5
46
47
48.5
50
54
56
57.5
59.5
61.5
63.5
65.7
67.5
72
74
76
77.5
84
86
87.5
89.5
91
94
96.5
99
103
106
109
112
122
125
129
132.5
143
147.5
151.5
155.5
165
168.5
172.5
176.5
26
40.5
41.8
43.0
44.3
45.5
46.8
48.0
49.5
53.5
55.5
57.0
58.8
60.8
63.0
65.1
67.0
71.5
73.3
75.3
77.0
83.0
85.0
86.8
88.8
90.3
93.0
95.8
98.3
102.0
105.0
108.0
111.0
120.5
124.0
127.5
131.0
141.8
146.0
150.0
154.0
163.5
167.0
171.0
175.0
27
40
41.5
42.5
44
45
46.5
47.5
49
53
55
56.5
58
60
62.5
64.5
66.5
71
72.5
74.5
76.5
82
84
86
88
89.5
92
95
97.5
101
104
107
110
119
123
126
129.5
140.5
144.5
148.5
152.5
162
165.5
169.5
173.5
28
39.7
41.2
42.2
43.7
44.7
46.2
47.2
48.7
52.5
54.3
55.8
57.5
59.8
61.8
63.8
65.8
70.1
71.6
73.6
75.6
81.4
83.4
85.2
87.1
88.7
91.5
94.2
96.7
100.0
103.0
105.8
108.8
117.6
121.4
124.6
128.1
138.9
143.0
147.0
151.0
160.3
163.8
167.8
171.9
Outdoor air temperature,
29
30
39.4
39
40.9
40.5
41.9
41.5
43.3
43
44.3
44
45.8
45.5
46.9
46.5
48.3
48
51.9
51.5
53.8
53
55.3
54.5
56.9
56.5
59.0
59
61.1
60.5
63.1
62.5
65.1
64.5
69.4
68.5
70.9
70
72.8
72
74.8
74
80.5
80
82.5
82
84.3
83.5
86.2
85.4
87.9
87
90.5
90
93.3
92.5
95.8
95
99.0
98
101.9
101
104.6
103.5
107.6
106.5
116.5
115
120.1
118.5
123.3
122
126.8
125.5
137.5
136
141.4
140
145.3
144
149.4
148
158.8
157
162.3
160.5
166.1
164.5
170.0
168.5
°C
31
38.8
40.3
41.3
42.5
43.5
45.0
46.3
47.5
50.8
52.5
54.0
55.8
58.0
59.8
61.8
63.8
67.8
69.3
71.0
73.0
79.0
81.0
82.5
84.5
86.3
89.0
91.5
94.0
97.0
99.8
102.3
105.3
114.0
117.3
120.5
124.0
134.5
138.3
142.0
146.3
155.5
159.0
162.8
166.5
32
38.5
40
41
42
43
44.5
46
47
50
52
53.5
55
57
59
61
63
67
68.5
70
72
78
80
81.5
83.5
85.5
88
90.5
93
96
98.5
101
104
113
116
119
122.5
133
136.5
140
144.5
154
157.5
161
164.5
33
38.2
39.4
40.7
41.7
42.7
44.0
45.2
46.5
49.2
51.3
52.8
54.3
56.3
58.0
60.1
62.1
65.8
67.6
69.1
70.9
77.4
79.1
80.7
82.7
84.2
86.7
85.2
91.7
94.5
97.2
99.7
102.5
111.1
114.3
117.3
120.6
130.9
134.4
138.2
142.2
152.0
155.5
159.0
162.6
34
37.8
39.1
40.3
41.3
42.3
43.5
44.8
46.0
48.8
50.7
52.2
53.7
55.7
57.5
59.5
61.4
65.2
66.9
68.4
70.1
76.6
78.4
79.9
81.8
83.3
85.8
84.3
90.8
93.5
96.3
98.8
101.5
110.0
113.2
116.2
119.4
129.6
133.1
136.8
140.8
150.5
154.0
157.5
160.9
35
37.5
38.5
40
41
42
43
44
45.5
48
50
51.5
53
55
56.5
58.5
60.5
64
66
67.5
69
76
77.5
79
81
82
84.5
79
89.5
92
95
97.5
100
108
111.5
114.5
117.5
127.5
131
135
138.5
148.5
152
155.5
159
29
A leader in Cooling, Heating and Indoor Air Quality
Extended
Warranty
Available
www.cdlweb.info
email: sales@cooldesignsltd.co.uk
tel.: 0191 549 6964
AQUACIAT
Air-cooled heat pumps
AQUACIAT heat pump model
Nominal cooling capacity*
EER/ESEER
Eurovent class
Nominal heating capacity**
COP/SCOP
Eurovent class
Sound power***/Sound pressure at 10 m****
Sound power extra low noise option***
Sound pressure at 10 m extra low noise option†
Width x length
Height (with buffer tank)
Weight - standard unit
Compressors
Minimum output
Maximum total air flow
Part Number (heat pump only)
• Screwed connection sleeves as standard.
• Anti-vibration mounts as standard.
• Brazed heat exchanger to offer high efficiency
and reduced refrigerant.
• Connect touch controller.
• Ice prevention frame coil heater.
ILD0150A
38
2.84/3.80
C
42
3.08/3.07
B
80/49
79
48
2109 x 1090
1440 (2040)
497
2
50
3692
7490822
ILD0180A
43
2.70/3.77
C
47
3.05/3.10
B
81/49
80
48
2109 x 1090
1440 (2040)
506
2
50
3690
7490823
ILD0200A
50
2.65/3.81
D
53
3.03/3.21
B
81/49
80
48
2109 x 1090
1440 (2040)
543
2
50
3910
7490824
ILD0240A
59
2.77/3.61
C
61
3.03/3.07
B
86/55
80
48
2109 x 1090
1440 (2040)
549
2
50
5285
7490825
ILD0260A
64
2.70/3.61
C
70
3.06/3.10
B
87/55
80
48
2109 x 1090
1440 (2040)
559
2
50
5284
7490826
ILD0300A
74
2.58/3.57
D
78
2.87/2.96
C
87/55
80
48
2109 x 1090
1440 (2040)
564
2
50
5282
7490827
7490822-AP
7490823-AP
7490824-AP
7490825-AP
7490826-AP
7490827-AP
AQUACIAT heat pump model
Nominal cooling capacity*
kW
EER/ESEER
kW/kW
Eurovent class
C1
Nominal heating capacity**
kW
COP/SCOP
kW/kW
Eurovent class
H1
Sound power***/Sound pressure at 10 m****
dB(A)
Sound power extra low noise option***
dB(A)
Sound pressure at 10 m extra low noise option**** dB(A)
Width x length
mm
Height (with buffer tank)
mm
Weight - standard unit
kg
Compressors
Scroll
Minimum output
%
Maximum total air flow
l/s
Part Number (heat pump only)
ILD0302A
78
2.79/3.84
C
80
3.08/3.14
B
84/52
83
52
2123 x 2270
1440 (2040)
777
3
33
7770
7491009
ILD0360A
86
2.70/3.77
C
93
3.02/3.17
B
84/52
83
51
2123 x 2270
1440 (2040)
896
3
33
7380
7490828
ILD0390A
96
2.7/3.88
C
101
3.09/3.23
B
84/52
83
51
2123 x 2270
1440 (2040)
905
3
33
7376
7490829
ILD0450A
113
2.69/4.04
D
117
3.06/3.23
B
84/52
83
51
2123 x 2270
1440 (2040)
979
3
33
7818
7490830
ILD0520A
132
2.77/3.75
C
138
3.07/3.14
B
90/58
83
51
2123 x 2270
1440 (2040)
1053
2+2
25
10568
7490831
ILD0600A
149
2.58/3.67
D
158
2.97/3.13
C
90/58
83
51
2123 x 2270
1440 (2040)
1057
2+2
25
10568
7490832
Part Number (heat pump with AquaPack)‡
7491009-AP
7490828-AP
7490829-AP
7490830-AP
7490831-AP
7490832-AP
Total price (heat pump only)†
Part Number (heat pump with AquaPack)‡
Total price (heat pump with AquaPack)
Total price (heat pump only)†
Total price (heat pump with AquaPack)
kW
kW/kW
C1
kW
kW/kW
H1
dB(A)
dB(A)
dB(A)
mm
mm
kg
Scroll
%
l/s
£
£
£
£
11,327
16,403
18,350
24,416
11,886
16,962
20,082
26,148
12,679
17,754
21,891
27,957
14,660
19,736
24,876
30,842
15,747
20,822
28,058
34,193
17,502
23,426
31,583
37,717
* Cooling mode conditions: water inlet/outlet temperature 12°C/7°C, ambient 35°C.
** Heating mode conditions: water inlet/outlet temperature 30°C/35°C, ambient 7°C/6°C.
*** In dB ref = 10-12 W, ‘A’ weighted. Measured in accordance with ISO 9614-1.
****In dB ref 20 uPa, ‘A’ weighted. For information, calculated from the sound power level Lw(A). Declared dual number noise emission values in
accordance with ISO 4871 (with an associated uncertainty of ±3 dB(A). Values are guidelines only. Refer to the unit name plate.
† Standard commissioning not included. Standard day’s commissionin will be charged at £620 per day. Terms apply.
‡ AquaPack includes: hydronic module116r, expansion tank 293, water buffer tank module 307, exchanger water filter 310A).
30
A leader in Cooling, Heating and Indoor Air Quality
AQUACIAT heat pump accessories
This is a compact and lightweight range of heat pumps
covering from 42 kW to 158 kW which uses round tube and
plate fin coils and EEV as standard, with direct start scroll
compressors, safety pressure relief valve, sight glass, head
pressure control, crankcase heaters, anti-short cycling, low
water temperature and low water flow protection, as well as
protection grille for condensing coil as standard.
www.cdlweb.info
email: sales@cooldesignsltd.co.uk
tel.: 0191 549 6964
Listed below are all of the available options that can be
purchased and factory fitted.
AQUACIAT heat pump model
Accessories - factory fitted
Pre-treatment corrosion protection
Medium brine application
Low brine application
Extra fan (180 to 240 mmCE available)*
Extra low noise (1 to 6 dB(A) depending on model)*
Soft Start
All year -20°C operation*
Water exchanger frost protection*
Exchanger and hydraulic frost protection
Master/slave operation
Hydraulic module (fixed-speed single pump) HP
Hydraulic module (fixed-speed dual pump) HP
Hydraulic module (fixed-speed single pump) LP
Hydraulic module (fixed-speed dual pump) LP
Hydraulic module (variable-speed single pump) HP
Hydraulic module (variable-speed dual pump) HP
BACnet over IP
External boiler management
Electric heater management
Reinforced ECM filtration for fan VFD
Reinforced ECM filtration for pump VFD
Expansion tank
Water buffer tank module
Exchanger flexible sleeve connections
Exchanger water filter
Set point adjustment by 4-20 mA signal
AQUACIAT heat pump model
Accessories - factory fitted
Pre-treatment corrosion protection
Medium brine application
Low brine application
Extra fan (180 to 240 mmCE available)*
Extra low noise (1 to 6 dB(A) depending on model)*
Soft Start
All year -20°C operation*
Water exchanger frost protection*
Exchanger and hydraulic frost protection
Master/slave operation
Hydraulic module (fixed-speed single pump) HP
Hydraulic module (fixed-speed dual pump) HP
Hydraulic module (fixed-speed single pump) LP
Hydraulic module (fixed-speed dual pump) LP
Hydraulic module (variable-speed single pump) HP
Hydraulic module (variable-speed dual pump) HP
BACnet over IP
External boiler management
Electric heater management
Reinforced ECM filtration for fan VFD
Reinforced ECM filtration for pump VFD
Expansion tank
Water buffer tank module
Exchanger flexible sleeve connections
Exchanger water filter
Set point adjustment by 4-20 mA signal
* Not available with some options.
Service & maintenance, Year 1
Service & maintenance, Years 1 & 2
Service & maintenance, Years 1, 2 & 3
ILD0150A
ILD0180A
ILD0200A
ILD0240A
ILD0260A
ILD0300A
Part
Total price, Total price, Total price, Total price, Total price, Total price,
Number
£
£
£
£
£
£
3A
156
156
156
156
156
156
5B
1,065
1,065
1,065
1,065
1,065
1,065
6B
1,819
1,819
1,819
1,819
1,819
1,819
12_1
1,001
1,001
1,001
1,001
1,001
1,001
15LS_1
437
437
437
437
437
437
25
750
750
750
750
750
750
28_1
931
931
931
931
931
931
42
488
488
488
488
488
488
42B
669
669
669
669
669
669
58
69
69
69
69
69
69
116R
869
869
869
869
869
869
116S
1,829
1,829
1,829
1,829
1,829
1,829
116T
631
631
631
631
631
631
116U
1,330
1,330
1,330
1,330
1,330
1,330
116V
1,620
1,620
1,620
1,620
1,620
1,620
116W
2,521
2,521
2,521
2,521
2,521
2,521
149
285
285
285
285
285
285
156A
53
53
53
53
53
53
156B
53
53
53
53
53
53
282A
126
126
126
126
126
126
282B
112
112
112
112
112
112
293
208
208
208
208
208
208
307
3,752
3,752
3,752
3,752
3,752
3,752
309A
403
403
403
403
403
403
310A
247
247
247
247
247
247
311
53
53
53
53
53
53
ILD0302A
ILD0360A
ILD0390A
ILD0450A
ILD0520A
ILD0600A
Part
Total price, Total price, Total price, Total price, Total price, Total price,
Number
£
£
£
£
£
£
3A
190
317
317
485
485
485
5B
1,770
1,770
1,770
1,770
1,770
1,770
6B
2,729
2,729
2,729
2,729
3,120
3,120
12_1
1,001
1,884
1,884
1,884
1,884
1,884
15LS_1
518
668
683
683
905
905
25
750
1,102
1,102
1,102
1,470
1,470
28_1
1,514
1,601
1,601
1,601
1,521
1,521
42
579
579
579
579
579
579
42B
669
688
688
688
688
688
58
87
69
69
69
69
69
116R
874
874
874
874
943
943
116S
1,792
1,792
1,792
1,943
1,943
1,943
116T
640
640
774
774
869
869
116U
1,295
1,295
1,572
1,572
1,790
1,790
116V
1,622
1,622
1,622
1,794
1,794
1,794
116W
2,483
2,483
2,483
2,748
2,748
2,748
149
285
285
285
285
285
285
156A
53
53
53
53
53
53
156B
53
53
53
53
53
53
282A
250
250
250
250
250
250
282B
112
112
112
112
112
112
293
286
286
286
286
286
286
307
4,550
4,550
4,550
4,550
4,550
4,550
309A
403
403
403
403
403
403
310A
353
353
353
353
353
353
311
53
53
53
53
53
53
1 to 2 systems, total price, £
1,875
3,844
5,911
3 to 4 systems, total price, £
3,750
7,688
11,822
Service & maintenance based on 3 x visits per annum
31
A leader in Cooling, Heating and Indoor Air Quality
www.cdlweb.info
email: sales@cooldesignsltd.co.uk
tel.: 0191 549 6964
AQUACIAT heat pump performance tables
Cooling capacities
AQUACIAT
heat pump
ILD0150A
ILD0180A
ILD0200A
ILD0240A
ILD0260A
ILD0300A
ILD0302A
ILD0360A
ILD0390A
ILD0450A
ILD0520A
ILD0600A
Leaving water
temp., °C
5/11
6/12
7/13
8/14
5/11
6/12
7/13
8/14
5/11
6/12
7/13
8/14
5/11
6/12
7/13
8/14
5/11
6/12
7/13
8/14
5/11
6/12
7/13
8/14
5/11
6/12
7/13
8/14
5/11
6/12
7/13
8/14
5/11
6/12
7/13
8/14
5/11
6/12
7/13
8/14
5/11
6/12
7/13
8/14
5/11
6/12
7/13
8/14
25
39.0
40.0
41.5
42.5
45
46
47.5
49
53
54.5
56
58
60
62
64
66
67
69
71
73
80
82
83.5
85.5
83
85
86.5
88.5
90
93
95.5
98
102
105
108
111
120.5
123.5
127.5
131
138.5
143
147.5
152.5
157.5
161
168
173
26
38.5
39.8
41.0
42.3
44.5
45.8
47.0
48.5
52.5
54.0
55.5
57.3
59.3
61.5
63.5
65.5
66.5
68.5
70.5
72.5
79.3
81.0
82.8
84.8
82.0
84.0
85.8
87.8
89.3
92.0
94.8
97.3
101.0
104.0
107.0
110.0
119.0
122.5
126.0
129.5
138.0
141.8
146.0
151.0
156.0
160.5
166.2
171.0
27
38.0
39.5
40.5
42.0
44
45.5
46.5
48
52
53.5
55
56.5
58.5
61
63
65
66
68
70
72
78.5
80
82
84
81
83
85
87
88.5
91
94
96.5
100
103
106
109
117.5
121.5
124.5
128
137.5
140.5
144.5
149.5
154.5
159
164.5
169.5
28
37.7
39.2
40.2
41.7
43.7
45.2
46.2
47.7
51.5
53.0
54.3
56.0
58.3
60.3
62.3
64.3
65.3
67.3
69.3
71.4
77.9
79.6
81.2
83.2
80.4
82.4
84.2
86.2
87.7
90.5
93.2
95.7
99.0
102.0
104.8
108.3
116.0
120.0
123.2
124.4
136.9
139.2
143.0
148.0
153.0
157.5
162.3
167.5
Outdoor air temperature,
29
30
37.4
37.0
38.9
38.5
39.9
39.5
41.3
41.0
43.3
43
44.8
44.5
45.9
45.5
47.3
47
50.9
50.5
52.5
52
53.9
53
55.4
55
57.5
57.5
59.6
59
61.6
61
63.6
63
64.5
64
66.6
66
68.6
68
70.5
70
77.0
76.5
78.8
78.5
80.4
79.5
82.3
81.5
79.5
79
81.5
81
83.3
82.5
85.3
84.5
86.9
86
89.5
89
92.3
91.5
94.8
94
98.0
97
100.9
100
103.6
102.5
106.9
106.5
114.7
113.5
114.5
117
122.0
121
120.9
124.5
135.5
136
138.0
136.5
141.5
140
146.5
145
151.5
150
156.0
154.5
160.7
159
165.8
164
°C
31
36.8
38.3
39.3
40.5
42.5
44.0
45.3
46.5
49.8
51.5
52.8
54.3
56.5
58.3
60.3
62.3
63.0
65.3
67.3
69.0
75.5
77.5
78.8
80.5
78.0
80.0
81.5
83.5
85.3
88.0
90.5
93.0
96.0
98.8
101.3
104.8
109.3
110.5
112.0
122.8
132.0
138.3
138.8
146.3
148.5
153.0
155.5
162.0
32
36.5
38.0
39.0
40.0
42
43.5
45
46
49
51
52.5
53.5
55.5
57.5
59.5
61.5
62
64.5
66.5
68
74.5
76.5
78
79.5
77
79
80.5
82.5
84.5
87
89.5
92
95
97.5
100
103
112
114.5
117.5
121
130
136.5
137.5
141.5
147
151.5
154
160
33
36.2
37.4
38.7
39.7
41.7
43.0
44.2
45.5
48.2
50.3
51.8
53.0
54.8
56.5
59.5
60.6
61.3
63.6
65.6
67.3
73.9
75.6
77.1
78.9
76.4
78.1
79.6
81.7
83.2
85.7
88.2
90.7
93.5
96.2
98.7
101.5
110.1
113.1
115.8
119.7
128.1
131.6
136.0
140.8
145.2
149.5
152.7
158.1
34
35.8
37.1
38.3
39.3
41.3
42.5
43.8
45.0
47.8
49.8
51.2
52.5
54.2
56.0
59.0
60.0
60.7
62.9
64.9
66.7
73.1
74.9
76.4
78.1
75.6
77.4
78.9
80.8
82.3
84.8
87.3
89.8
92.5
95.3
97.8
100.5
109.0
111.9
114.7
118.4
126.3
130.0
134.3
139.0
143.8
148.0
151.4
156.3
35
35.5
36.5
38.0
39.0
41
42
43
44.5
47
49
50.5
52
53.5
55
59
59
60
62
64
66
72.5
74
75.5
77.5
75
76.5
78
80
81
83.5
86
88.5
91
94
96.5
99
107
110.5
113
117
124.5
128.2
132
136.2
142
146
150
154.5
32
A leader in Cooling, Heating and Indoor Air Quality
www.cdlweb.info
email: sales@cooldesignsltd.co.uk
tel.: 0191 549 6964
AQUACIAT heat pump performance tables
Heating capacities
AQUACIAT
heat pump
ILD0150A
ILD0180A
ILD0200A
ILD0240A
Outdoor air
temp., °C
-5
-4
-3
-2
-1
0
1
2
3
4
5
6
7
-5
-4
-3
-2
-1
0
1
2
3
4
5
6
7
-5
-4
-3
-2
-1
0
1
2
3
4
5
6
7
-5
-4
-3
-2
-1
0
1
2
3
4
5
6
7
30/35°C
Instantaneous, kW
32
32.75
33.5
34.6
35.1
36
37
38
39.1
39.6
40.5
41.75
43
35
36
37
38.1
38.6
39.5
40.5
41.5
42.8
43.4
44.5
45.75
47
40.5
41.5
42.5
44.0
44.7
46
47
48
49.8
50.5
52
53.5
55
46.5
47.75
49
50.7
51.5
53
54.25
55.5
57.5
58.3
60
61.5
63
Integrated, kW
24
25.25
26.5
28.6
29.0
31
32.75
34.5
37.1
37.6
40
41.6
43
27
28
29
31.6
32.1
34.5
36.25
38
40.8
41.4
44
45.7
47
31
32.25
33.5
35.5
36.9
39.5
41.75
44
47.3
48.0
51
53
55
37
38.5
40
42.8
43.4
46
48
50
54.2
55.1
59
61
63
Leaving water temperature, °C
40/45°C
Instantaneous, kW
Integrated, kW
32
23
32.75
24
33.5
25
34.3
27.1
34.8
27.5
35.5
29.5
36.5
31
37.5
32.5
38.6
35.6
39.1
36.1
40
39
41
41
42
42
35.5
25.5
36.25
26.75
37
28
38.3
30.3
38.9
30.8
40
33
40.75
34.75
41.5
36.5
42.8
39.8
43.4
40.4
44.5
43.5
45.75
45.25
47
47
40
29
41
30.25
42
31.5
43.5
34.3
44.2
34.8
45.5
37.5
46.5
39.5
47.5
41.5
49.0
45.5
49.7
46.2
51
50
52
51.5
53
53
45.5
35.5
46.75
36.25
48
37
49.8
39.8
50.5
40.4
52
43
53.25
44.75
54.5
46.5
56.2
51.5
57.1
52.3
58.5
57
59.75
59
61
61
45/50°C
Instantaneous, kW
32
32.75
33.5
34.3
34.8
35.5
36.25
37
38.1
38.6
39.5
40.5
41.5
35
35.75
36.5
37.6
38.1
39
40
41
42.0
42.7
43.5
44.75
46
40
41
42
43.3
43.9
45
46
47
48.5
49.2
50.5
51.5
52.5
44.5
45.75
47
48.5
49.2
50.5
51.75
53
54.7
55.6
57
58.5
60
Integrated, kW
23
24
25
26.9
27.3
29
30.5
32
35.1
35.6
38.5
40
41.5
25
26
27
29.4
29.8
32
33.75
35.5
39.1
39.6
43
44.5
46
28.5
29.75
31
33.8
34.3
37
38.75
40.5
44.5
45.2
49
50.75
52.5
33.5
34.75
36
37.8
39.1
41.5
43.25
45
50.0
50.8
55.5
57.75
60
33
A leader in Cooling, Heating and Indoor Air Quality
www.cdlweb.info
email: sales@cooldesignsltd.co.uk
tel.: 0191 549 6964
AQUACIAT heat pump performance tables
Heating capacities (continued)
AQUACIAT
heat pump
ILD0260A
ILD0300A
ILD0302A
ILD0360A
Outdoor air
temp., °C
-5
-4
-3
-2
-1
0
1
2
3
4
5
6
7
-5
-4
-3
-2
-1
0
1
2
3
4
5
6
7
-5
-4
-3
-2
-1
0
1
2
3
4
5
6
7
-5
-4
-3
-2
-1
0
1
2
3
4
5
6
7
30/35°C
Instantaneous, kW
53
54.25
55.5
57.5
58.3
60
60.5
61
64.2
66.0
68
69.5
71
59
60.5
62
64.2
65.2
67
68.75
70.5
72.9
74.0
76
78
80
60.5
62.25
64
66.2
67.2
69
70.75
72.5
75.1
76.3
78.5
80.4
83
70.5
72
74
76.6
77.8
80
81.9
84
86.0
88.1
90.5
92.6
95
Integrated, kW
42
42.9
45
48.0
48.7
51.5
53.75
56
61.2
63.0
67
69
71
47
48.75
50.5
54.0
55.4
58
60.5
63
66.9
69.4
74.5
77.25
80
48
49.75
51.5
55.0
55.8
59
61.75
64.5
70.4
71.5
77
80.4
83
55.5
57
60
63.9
64.9
68.5
71.3
74.5
79.0
82.3
88.5
92.6
95
Leaving water temperature, °C
40/45°C
Instantaneous, kW
Integrated, kW
52.5
40
53.75
41
55
42
56.0
44.0
53.5
45.7
59
48.5
60.5
50.5
62
52.5
63.9
58.5
64.9
59.3
66.5
65
67.9
67.5
70
70
58.5
44.5
60
46
61.5
47.5
63.4
50.7
64.4
51.5
66
54.5
67.5
56.75
69
59
71.1
65.4
72.2
66.4
74
72.5
75.5
75.5
78
78
59.5
45
61
46.5
62.5
48
64.7
51.2
65.7
52.0
67.5
55
69
57.25
70.5
59.5
72.9
64.3
74.0
69.0
76
74
72.2
64.3
80
80
69
52
78
77
72.5
55.5
74.4
58.0
76.3
60.4
78.5
64
74.4
57.9
82
69.5
84.8
77.4
86.1
78.5
88.5
86
92.6
90.5
93
93
45/50°C
Instantaneous, kW
52
53.25
54.5
56.2
57.1
58.5
59.75
61
62.7
63.6
65
66.75
68.5
58.5
59.75
61
62.9
63.9
65.5
67
68.5
70.4
71.5
73
74.75
76.5
59
60.5
62
63.9
64.9
66.5
68
69.5
71.6
72.7
74.5
76.0
78
67.5
69.4
71
73.6
74.7
77
78.6
80.5
83.1
84.3
86.5
88.4
90.5
Integrated, kW
39
40.25
41.5
44.0
44.7
47
49.25
51.5
57.2
58.1
63.5
66
68.5
44
45.5
47
50.0
51.2
53.5
55.75
58
64.2
65.2
71
73.75
76.5
44
45.5
47
50.0
50.8
53.5
55.75
58
64.9
65.9
72.5
76.0
78
50.5
51.6
54
57.7
58.6
62
64.6
67.5
75.4
76.5
84
88.4
90.5
34
A leader in Cooling, Heating and Indoor Air Quality
www.cdlweb.info
email: sales@cooldesignsltd.co.uk
tel.: 0191 549 6964
AQUACIAT heat pump performance tables
Heating capacities (continued)
AQUACIAT
heat pump
ILD0390A
ILD0450A
ILD0520A
ILD0600A
Outdoor air
temp., °C
-5
-4
-3
-2
-1
0
1
2
3
4
5
6
7
-5
-4
-3
-2
-1
0
1
2
3
4
5
6
7
-5
-4
-3
-2
-1
0
1
2
3
4
5
6
7
-5
-4
-3
-2
-1
0
1
2
3
4
5
6
7
30/35°C
Instantaneous, kW
77
78.7
80.5
83.3
84.6
87
89.0
91
93.4
95.5
98
100.5
103
89
91.3
93.5
97.0
98.5
101.5
104.0
106.5
110.2
111.9
115
117.7
121
105
107.5
110
113.9
115.7
119
121.8
125
129.1
131.1
134.5
137.0
141
120
123
126.5
130.8
132.8
136.5
139.8
143.5
147.0
150.5
154.5
158.0
162
Integrated, kW
61
62.3
65
69.4
70.5
74.5
77.5
81
85.8
89.6
96.5
100.5
103
71
72.2
75
79.6
81.5
85
88.0
92
101.7
105.0
112.5
117.7
121
84
85
89
95.0
97.4
102
106.4
111
120.9
122.7
132
137.0
141
96
98
105
110.9
112.6
118
123.0
128.5
136.0
141.7
152
158.0
162
Leaving water temperature, °C
40/45°C
Instantaneous, kW
Integrated, kW
76
57.5
78.1
58.7
80
61.5
82.6
65.4
83.8
66.4
86
70
87.8
72.9
90
76
92.5
84.6
93.9
85.9
96
94
98.5
98.5
101
101
88
66
90
67.4
92
70
95.0
74.1
96.5
75.3
99
79
101.3
82.0
103.5
85
107.0
96.0
108.6
97.5
111.5
108
114.0
114.0
117
117
104
79
106.4
80
109
83.5
111.5
87.5
114.0
91.5
117
95.6
120.0
100.0
122.5
104
126.4
115.4
128.3
117.2
131.5
128
134.5
134.5
138
138
119.5
90.5
122
92.7
125
97
129.1
101.5
131.1
105.1
134.5
111
137.0
115.5
140.5
120.5
144.0
129.0
147.2
138.0
151
147.5
154.0
154.0
158
158
45/50°C
Instantaneous, kW
76
77.5
79.5
81.8
83.1
85
86.8
88.8
90.0
92.8
95
97.0
99
87.5
89.4
91.5
94.3
95.7
98
100.0
102.5
105.5
107.1
109.5
112.0
114.5
103
105.6
108
111.2
112.9
115.5
110.4
121
124.4
126.3
129
132.0
135.5
119
122
125
128.6
130.6
133.5
136.4
139.5
143.5
145.7
149
152.0
155.5
Integrated, kW
56.5
57
60
62.9
64.9
68.5
71.4
74.5
83.1
86.0
92.5
97.0
99
65
66.4
69
72.9
74.0
77.5
80.2
83
94.0
98.0
106
112.0
114.5
77.5
78.4
82
87.3
88.6
93.5
97.6
102
113.4
115.2
126
132.0
135.5
89.5
91.8
96
102.0
103.5
109
113.7
118.5
131.3
136.0
145.5
152.0
155.5
35
A leader in Cooling, Heating and Indoor Air Quality
www.cdlweb.info
email: sales@cooldesignsltd.co.uk
tel.: 0191 549 6964
COADIS LINE 600
Cassette fan coil unit
•
•
•
•
•
•
Suction/discharge through 180° or 360° FLEXIWAY grille.
Installation in reduced ceilings with modern styling.
Air supply with Coanda effect for guaranteed comfort.
Epure filter for excellent air quality.
Manufactured according to eco-concept, 87% recyclable.
Quiet, standard or energy-efficient HEE motor.
For cooling or heating (2-pipe)
Unit
Coadis Line
Motor
612
Standard
622
Standard
632
Standard
612
HEE
622
HEE
632
HEE
Cooling
W
2040
2600
4290
2040
2600
4290
Heating
W
2980
3610
5500
2980
3610
5500
Part Number
7401354
7401355
7401356
7401351
7401352
7401353
591
626
687
712
743
802
For cooling or heating (4-pipe)
Unit
Coadis Line
Motor
624
Standard
634
Standard
624
HEE
634
HEE
Cooling
W
2600
4290
2600
4290
Heating
W
3660
3720
3660
3720
Part Number
Total price, £
Select from 1-way or 4-way grille
Description
180° suction/discharge grille with Epure filter 600
360° suction/discharge grille with Epure filter 600
Total price, £
2-pipe
4-pipe
7401359
7401360
7401357
7401358
653
747
966
867
Part Number
7350577
7350575
Total price, £
Included
Included
Available unit options
Description
Part Number
Total price, £
Increased performance kit
7301625
72
4-way water control valve* (2-pipe)
E037567
83
2-way water control valve* (2-pipe)
E037605
70
2-piece 4-way water control valve* (4-pipe)
E037583
166
2-piece 2-way water control valve* (4-pipe)
E037621
139
Condensate pump*
7301623
105
Wall-mounted thermostat RTR 7011/RTR 7203*
5201018/5201021
30/51
Set of mounting rubbers (per unit)*
Set = 4 x 0219453
6
All units are supplied with an Epure air filter as standard. These Epure filters need to be replaced periodically. Replacement filters can be found at
the back of this price list.
* Options supplied separately. All water control valves, equipped with 230 V/1 ph/50 Hz thermal actuator (open/closed). Other arrangements on request.
The above capabilities are based on Eurovent conditions. For 2-pipe unit, cooling with an air inlet temperature of 27°C/WB 19°C and a water
range of 7-12°C, heating with an air inlet temperature of 20°C/50% RH and a water inlet of 50°C at high fan speed. For 4-pipe unit, cooling with
an air inlet temperature of 27°C/WB 19°C and a water range of 7-12°C, heating with an air inlet temperature of 20°C/50% RH and a water range
of 70-60°C at high fan speed. Alternative 2-pipe units are available with electric heating. CIAT participates in the Eurovent certification program.
For a list of products and certified characteristics, please refer to www.eurovent-certification.com.
36
A leader in Cooling, Heating and Indoor Air Quality
www.cdlweb.info
email: sales@cooldesignsltd.co.uk
tel.: 0191 549 6964
•
•
•
•
•
•
Suction/discharge through 360° FLEXIWAY grille.
Installation in reduced ceilings with modern styling.
Air supply with Coanda effect for guaranteed comfort.
Epure filter for excellent air quality.
Manufactured according to eco-concept, 87% recyclable.
Quiet, standard or energy-efficient HEE motor.
COADIS LINE 900
Cassette fan coil unit
For cooling or heating (2-pipe)
Unit
Coadis Line
Motor
922
Standard
932
Standard
922
HEE
932
HEE
932SP
HEE
Cooling
W
6100
7640
6060
7600
9350
Heating
W
7730
9000
7770
9040
11200
Part Number
Total price, £
7344009
7344010
7344015
7344016
7351393
1,040
1,310
1,129
1,413
1,536
For cooling or heating (4-pipe)
Unit
Coadis Line
Motor
924
Standard
934
Standard
924
HEE
934
HEE
934SP
HEE
Cooling
W
6100
7640
6060
7600
9350
Heating
W
4100
5070
4110
5090
5720
Part Number
Total price, £
7344011
7344012
7344017
7344018
7351394
1,118
1,418
1,056
1,521
1,653
Part Number
7335537
Total price, £
Included
4-way grille
Description
360° suction/discharge grille with Epure filter
2-pipe
4-pipe
Available unit options
Description
Part Number
Total price, £
4-way water control valve* (2-pipe)
E037575
99
2-way water control valve* (2-pipe)
E037613
81
2-piece 4-way water control valve* (4-pipe)
E037591
182
2-piece 2-way water control valve* (4-pipe)
E037648
150
Condensate pump for 900 included
7301623
Included
Wall-mounted thermostat RTR 7011/RTR 7203*
5201018/5201021
30/51
Set of mounting rubbers (per unit)*
Set = 4 x 0219453
6
All units are supplied with an Epure air filter as standard. These Epure filters need to be replaced periodically. Replacement filters can be found at
the back of this price list.
* Options supplied separately. All water control valves, equipped with 230 V/1 ph/50 Hz thermal actuator (open/closed). Other arrangements on
request.
The above capabilities are based on Eurovent conditions. For 2-pipe unit, cooling with an air inlet temperature of 27°C/WB 19°C and a water
range of 7-12°C, heating with an air inlet temperature of 20°C/50% RH and a water inlet of 50°C at high fan speed. For 4-pipe unit, cooling with
an air inlet temperature of 27°C/WB 19°C and a water range of 7-12°C, heating with an air inlet temperature of 20°C/50% RH and a water range
of 70-60°C at high fan speed. Alternative 2-pipe units are available with electric heating. CIAT participates in the Eurovent certification program.
For a list of products and certified characteristics, please refer to www.eurovent-certification.com.
37
A leader in Cooling, Heating and Indoor Air Quality
www.cdlweb.info
email: sales@cooldesignsltd.co.uk
tel.: 0191 549 6964
COMFORT LINE
Ducted type fan coil
For cooling or heating (2-pipe) with G3 filter
Unit
Cooling
Comfort Line
W
12B
1540
12D
1970
12E
2360
22C
3060
22D
3510
22E
3810
32C HEE only
5000
32D HEE only
5550
32E HEE only
5780
42C HEE only
5760
42D HEE only
6630
42E HEE only
7040
52C HEE only
7570
52D HEE only
8110
52E HEE only
9350
62B HEE only
11700
62D HEE only
14400
62E HEE only
16800
• Comfort unit for flexible installation.
• Modular air supply configuration, through
expanded capabilities.
• Especially low sound level.
• Optional Epure filter for excellent air quality.
• Optional HEE (high energy-efficiency) motor for
exceptional savings of up to 87%.
• Equipped with flange on discharge frame.
• Very easy unit maintenance.
Heating
W
2390
2770
3050
4550
4920
5150
7820
8490
8600
8220
8890
9130
10500
11200
12100
17000
19700
21900
Part Number
AC motor
CFL-12B-AC-G3
CFL-12D-AC-G3
CFL-12E-AC-G3
CFL-22C-AC-G3
CFL-22D-AC-G3
CFL-22E-AC-G3
CFL-32C-AC-G3
CFL-32D-AC-G3
CFL-32E-AC-G3
CFL-42C-AC-G3
CFL-42D-AC-G3
CFL-42E-AC-G3
CFL-52C-AC-G3
CFL-52D-AC-G3
CFL-52E-AC-G3
CFL-62B-AC-G3
CFL-62D-AC-G3
CFL-62E-AC-G3
For cooling or heating (4-pipe) with G3 filter
Unit
Cooling
Heating
Comfort Line
W
W
14B
1540
2730
14D
2000
3780
24C
3060
3440
24D
3600
4670
34C HEE only
4970
5670
34D HEE only
5680
7630
44C HEE only
5710
6230
44D HEE only
6680
6190
54C HEE only
7530
8160
54D HEE only
8350
8110
64B HEE only
12100
21300
64D HEE only
15400
21300
All units are supplied with a G3 air filter as standard.
Part Number
AC motor
CFL14B-AC-G3
CFL14D-AC-G3
CFL24C-AC-G3
CFL24D-AC-G3
CFL34C-AC-G3
CFL34D-AC-G3
CFL44C-AC-G3
CFL44D-AC-G3
CFL54C-AC-G3
CFL54D-AC-G3
CFL64B-AC-G3
CFL64D-AC-G3
Total price, £
2-pipe (model I AC)
332
350
361
381
394
405
451
468
476
495
513
537
582
609
651
887
988
1,062
Total price, £
4-pipe (model I AC)
364
380
409
426
482
508
534
560
629
674
1,029
1,086
Part Number
HEE Motor
CFL-12B-HEE-G3
CFL-12D-HEE-G3
CFL-12E- HEE -G3
CFL-22C- HEE -G3
CFL-22D- HEE -G3
CFL-22E- HEE -G3
CFL-32C- HEE -G3
CFL-32D- HEE -G3
CFL-32E- HEE -G3
CFL-42C- HEE -G3
CFL-42D- HEE -G3
CFL-42E- HEE -G3
CFL-52C- HEE -G3
CFL-52D- HEE -G3
CFL-52E- HEE -G3
CFL-62B- HEE -G3
CFL-62D- HEE -G3
CFL-62E- HEE -G3
Part Number
HEE Motor
CFL14B-HEE-G3
CFL14D- HEE-G3
CFL24C- HEE-G3
CFL24D- HEE-G3
CFL34C- HEE-G3
CFL34D- HEE-G3
CFL44C- HEE-G3
CFL44D- HEE-G3
CFL54C- HEE-G3
CFL54D- HEE-G3
CFL64B- HEE-G3
CFL64D- HEE-G3
Total price, £
2-pipe (model I HEE)
448
465
477
485
498
509
567
585
593
610
629
653
689
717
758
1,075
1,176
1,251
Total price, £
4-pipe (model I HEE)
479
496
513
530
599
652
650
675
736
781
1,217
1,274
38
A leader in Cooling, Heating and Indoor Air Quality
www.cdlweb.info
email: sales@cooldesignsltd.co.uk
tel.: 0191 549 6964
COMFORT LINE
Available options
Available unit options
Description
Surcharge for 200 mm supply air spigots
(for model Y)
Surcharge for 200 mm supply and return
air spigots (for model H)
Size 1
7344898
Size 2
7344888
Size 3
7344889
Size 4
7344910
Size 5
7344911
Size 6
7380251
7344898 +
7344936
7344888 +
7344930
7344889 +
7344931
7344910 +
7344941
7344911 +
7344942
7380251 +
7380259
£27
£66
£18
Epure filter
£33
£78
£28
£42
£99
£27
£45
£110
£33
£129
£47
£92
£209
£66
Part Number
Total price, £
5201018/5201021
30/51
7394451
118
Set = 4 x 0219453
6
Description
Wall-mounted thermostat RTR 7011/RTR 7203*
Condensate pump*
Set of mounting rubbers (per unit)*
Available unit options
Description
2-pipe units
4-way water control valve*
E037567
4-way water control valve*
E037575
2-way water control valve*
E037605
2-way water control valve*
E037613
£51
Total price, £
Total price, £
Total price, £
Total price, £
Total price, £
Total price, £
83
83
83
-
-
-
Size 1
Size 2
Size 3
Size 4
Size 5
Size 6
-
-
-
99
99
99
70
70
70
-
-
-
-
-
-
81
81
81
4-pipe units
Size 1
Size 2
Size 3
Size 4
Size 5
Size 6
2-piece 4-way water control valve*
166
166
166
E037583
2-piece 4-way water control valve*
182
182
182
E037591
2-piece 2-way water control valve*
139
139
139
E0376210
2-piece 2-way water control valve*
150
150
150
E037648
* Options supplied separately. All water control valves, equipped with 230 V/1 ph/50 Hz thermal actuator (open/closed). Other arrangements on request.
The above capabilities are based on Eurovent conditions. For 2-pipe unit, cooling with an air inlet temperature of 27°C/WB 19°C and a water
range of 7-12°C, heating with an air inlet temperature of 20°C/50% RH and a water inlet of 50°C at high fan speed. For 4-pipe unit, cooling with
an air inlet temperature of 27°C/WB 19°C and a water range of 7-12°C, heating with an air inlet temperature of 20°C/50% RH and a water range
of 70-60°C at high fan speed. Alternative 2-pipe units are available with electric heating. CIAT participates in the Eurovent certification program.
For a list of products and certified characteristics, please refer to www.eurovent-certification.com.
39
A leader in Cooling, Heating and Indoor Air Quality
www.cdlweb.info
email: sales@cooldesignsltd.co.uk
tel.: 0191 549 6964
MAJOR LINE CV/CH
Cabinet unit
For cooling or heating (2-pipe)
Unit
Major Line
102A
102C
202A
202C
202D
302A
302B
302C
402C
502C
602D
•
•
•
•
•
•
Cooling
W
1410
1800
2370
3070
3360
3530
4280
4910
6480
7650
9970
For cooling and heating (4-pipe)
Unit
Cooling
Major Line
W
104X
1800
204X
3070
304X
4910
404X
6480
504X
7650
604X
9030
All units are supplied with a G3 air filter as standard.
Available unit options
Description
Option for energy-efficient HEE brushless motor (per unit)
For cooling and/or heating.
Available in 6 unit sizes.
Easy unit installation and maintenance.
One unit model for both vertical and horizontal usage.
Highly suitable for offices and hotel rooms.
HEE motor available as an option.
Heating
W
4440
4860
7450
8880
9290
12300
12700
14300
19400
21900
27000
Part Number
Total price, £
7243000
7243016
7243040
7243056
7243068
7243080
7243092
7243096
7243136
7243176
7243216
282
296
303
323
327
357
360
380
421
468
581
Heating
W
1970
3360
5220
7110
8510
10100
Part Number
Total price, £
4-pipe
7243032
7243072
7243112
7243152
7243192
7243220
322
351
411
458
512
595
Part Number
-
Total price, £
120
40
A leader in Cooling, Heating and Indoor Air Quality
www.cdlweb.info
email: sales@cooldesignsltd.co.uk
tel.: 0191 549 6964
•
•
•
•
•
•
For cooling and/or heating.
Available in 6 unit sizes.
Easy unit installation and maintenance.
One unit model for both vertical and horizontal usage.
Highly suitable for offices and hotel rooms.
HEE motor available as an option.
For cooling or heating (2-pipe)
Unit
Major Line
102A
102C
202A
202C
202D
302A
302B
302C
402C
502C
602D
Cooling
W
1410
1800
2370
3070
3360
3530
4280
4910
6480
7650
9970
For cooling and heating (4-pipe)
Unit
Cooling
Major Line
W
104X
1800
204X
3070
304X
4910
404X
6480
504X
7650
604X
9030
All units are supplied with a G3 air filter as standard.
Available unit options
Description
Option for energy-efficient HEE brushless motor (per unit)
MAJOR LINE NCV/NCH
Concealed unit
Heating
W
4440
4860
7450
8880
9290
12300
12700
14300
19400
21900
27000
Part Number
Total price, £
7243250
7243266
7243290
7243306
7243318
7243330
7243342
7243346
7243386
7243426
7243466
225
240
243
262
267
291
294
313
349
386
492
Heating
W
1970
3360
5220
7110
8510
10100
Part Number
Total price, £
4-pipe
7243282
7243322
7243362
7243402
7243442
7243470
265
291
345
385
430
506
Part Number
-
Total price, £
120
41
A leader in Cooling, Heating and Indoor Air Quality
www.cdlweb.info
email: sales@cooldesignsltd.co.uk
tel.: 0191 549 6964
MAJOR LINE
Cabinet and concealed unit options
Available unit options
Description
2-pipe units
4-way water control valve*
E037567
4-way water control valve*
E037575
2-way water control valve*
E037605
2-way water control valve*
E037567
4-pipe units
2-piece 4-way water control valve*
E037583
2-piece 4-way water control valve*
E037591
2-piece 2-way water control valve*
E037621
2-piece 2-way water control valve*
E037648
Total price, £
Total price, £
Total price, £
Total price, £
Total price, £
Total price, £
83
83
83
83
-
-
102
202
302
402
502
602
-
-
-
-
99
99
70
70
70
70
-
-
-
-
-
-
81
81
166
104
166
204
166
304
166
404
504
604
-
-
-
-
182
182
139
139
139
139
-
-
-
-
-
-
150
150
-
-
All unit sizes
Description
Part Number
Total price, £
Energy-efficient HEE brushless motor
120
Condensate pump*
7203415
140
Wall-mounted thermostat RTR 7011/RTR 7203*
5201018/5201021
30/51
Built-in thermostat V30 (vertical cabinet installation only)
79
Set of mounting rubbers (per unit)*
Set = 4 x 0219453
6
* Options supplied separately. All water control valves, equipped with 230 V/1 ph/50 Hz thermal actuator (open/closed). Other arrangements on request.
The above capabilities are based on Eurovent conditions. For 2-pipe unit, cooling with an air inlet temperature of 27°C/WB 19°C and a water
range of 7-12°C, heating with an air inlet temperature of 20°C/50% RH and a water inlet of 50°C at high fan speed. For 4-pipe unit, cooling with
an air inlet temperature of 27°C/WB 19°C and a water range of 7-12°C, heating with an air inlet temperature of 20°C/50% RH and a water range
of 70-60°C at high fan speed. Alternative 2-pipe units are available with electric heating. CIAT participates in the Eurovent certification program.
For a list of products and certified characteristics, please refer to www.eurovent-certification.com.
42
A leader in Cooling, Heating and Indoor Air Quality
DX Option
Available
On Request
•
•
•
•
•
•
•
•
•
•
FLOWAY ACCESS
Air handling unit
Dual flow ‘plug and play’ air handling unit.
Double filtration (F7 and F9).
Rotary heat exchanger with constant speed.
Free cooling and night cooling management.
EC fan motor.
Casing mechanical strength = D2.
Air leakage (± pressure) = L2.
Air leakage filter assembly = F9.
Thermal transmittance = T3.
Thermal bridge = TB2.
Floway Access
Air flow
Minimum air flow
Maximum air flow
V air filter section
Recovery efficiency EN308*
Width x height
Length
Weight
Supply power
Supply
Fans (supply and extract)
www.cdlweb.info
email: sales@cooldesignsltd.co.uk
tel.: 0191 549 6964
m3/s
m3/s
m3/s
m/s
%
mm
mm
kg
kW
Phase
1000
0.3
0.083
0.333
1.21
79.0
810 x 958
1266
201
1.43
1Ø
£
£
6,227
7,169
8,143
9,229
10,697
11,903
12,613
13,906
12,613
13,906
15,008
16,517
15,008
16,517
Floway Access c/w hot water coil (1-row)
Fan motor assembly supply
W
Fan motor assembly exhaust
W
Specific fan power
kW/m3/s
Heating water coil capacity**
kW
258
230
1.626
4.0
542
478
1.700
7.9
819
726
1.716
11.9
892
819
1.487
15.2
1234
1101
1.668
18.5
1162
1064
1.310
22.5
1821
1629
1.568
29.1
Price
6,866
8,861
11,576
13,619
13,619
16,246
16,246
Floway Access cooling and heating/cooling only coil (2-row)
Fan motor assembly supply
W
278
Fan motor assembly exhaust
W
230
Specific fan power
kW/m3s
1.694
Changeover coil capacity (heating)**
kW
4.0
Changeover coil capacity (cooling)***
kW
5.7
553
478
1.719
7.9
11.4
832
726
1.731
11.9
17.1
923
819
1.514
15.2
21.9
1256
1101
1.684
18.5
26.6
1199
1064
1.331
22.5
32.3
1851
1629
1.582
29.1
41.8
Price
9,037
11,775
13,811
13,811
16,469
16,469
Price****
Price****
including electric heater (2-stage)
£
£
7,065
2000
3000
5000
5000
7500
7500
0.6
0.9
1.2
1.4
1.7
2.2
0.139
0.194
0.250
0.250
0.389
0.389
0.694
1.028
1.583
1.583
2.361
2.361
1.42
1.42
1.16
1.45
1.18
1.57
79.0
78.7
81.0
78.3
81.6
78.2
1010 x 1158 1210 x 1359 1510 x 1659 1510 x 1659 1810 x 1959 1810 x 1959
1310
1600
1600
1600
1600
1600
309
432
604
604
751
751
2.5
3.82
4.23
4.23
6.03
6.03
3Ø + T
3Ø + T
3Ø + T
3Ø + T
3Ø + T
3Ø + T
Polypropylene
Aluminum
Aluminum
Aluminum
Aluminum
* ERP regulation UE 1253/2014.
** Capacity at (W 45-40°C)
*** Capacity at (W 7-12°C)
****Includes casing/heat recovery/control and display/set of fans/M5 and F7 filter/Modbus
43
A leader in Cooling, Heating and Indoor Air Quality
www.cdlweb.info
email: sales@cooldesignsltd.co.uk
tel.: 0191 549 6964
FLOWAY ACCESS
Air handling unit accessories
Accessories
Floway Access
Description
Filter - F9 HEE
Set of aluminum fans (supply and exhaust)
Energy meter with communication
Actuator damper – indoor AHU
Dimensions
Actuator damper – outdoor AHU
Dimensions
Flexible sleeve (intake OR discharge)
Dimensions
Roof
Hood
Separator screen for hood
Adjustable feet
Quantity
Multi-units display (1-30) (display + TCONN card)
LON PCB
KNX PCB
Modbus TCP – BACnet IP PCB
Webserver PCB
IAQ sensor kit (CO2)
Constant pressure management kit
Ambient in-room control kit
Smoke detector kit
RJ11 cable 10 m/50 m
£
£
£
£
mm
£
mm
£
mm
£
£
£
£
£
£
£
£
£
£
£
£
£
£
1000
2000
3000
5000
7500
77
1132
843
128
250 diameter
296
370 x 370
17
250 dia
346
184
28
64
4
160
280
280
359
439
559
203
184
319
14/53
115
1456
1,155
168
355 diameter
312
470 x 470
20
355 dia
363
200
44
96
6
160
280
280
359
439
559
203
184
319
14/53
132
1809
1,155
343
1150 x 560
343
1150 x 560
76
990 x 510
389
228
80
128
8
160
280
280
359
439
559
203
184
319
14/53
232
Inc
1,155
375
1450 x 650
375
1450 x 650
91
1290 x 610
449
256
96
128
8
160
280
280
359
439
559
203
184
319
14/53
271
Inc
1,155
415
1750 x 840
415
1750 x 84
112
1590 x 810
518
287
119
128
8
160
280
280
359
439
559
203
184
319
14/53
44
A leader in Cooling, Heating and Indoor Air Quality
www.cdlweb.info
email: sales@cooldesignsltd.co.uk
tel.: 0191 549 6964
•
•
•
•
•
•
•
•
•
•
•
FLOWAY CLASSIC
Air handling unit
Rotary heat exchanger
Dual flow ‘plug and play’ air handling unit.
Double filtration (F7 and F9).
Rotary heat exchanger with variable speed.
Free cooling and night cooling management.
EC fan motor.
Electrical pre-heater available = -15°C heat recovery.
Casing mechanical strength = D2.
Air leakage (± pressure) = L2.
Air leakage filter assembly = F9.
Thermal transmittance = T3.
Thermal bridge = TB2.
Floway Classic
Air flow
Minimum air flow
Maximum air flow
V air filter section
Recovery efficiency EN308*
Width x height
m3/s
m3/s
m3/s
m/s
%
mm
Length
mm
1000
0.30
0.083
0.333
1.21
78.8
810 x
958
1266
kg
kW
Phase
201
1.43
1Ø
£
7,517
Weight
Supply power
Supply
Price**
2000
0.55
0.139
0.694
1.42
79.4
1010 x
1158
510 +
800
309
2.5
3Ø + T
£
808
715
1.692
11.9
£
5000
1.35
0.25
1.583
1.45
79.9
1510 x
1659
800 +
800
604
4.23
3Ø + T
6000
1.70
0.389
2.361
1.18
79.1
1810 x
1959
800 +
800
702
6.03
3Ø + T
7500
2.20
0.389
2.361
1.57
79.5
1810 x
1959
800 +
800
751
6.03
3Ø + T
10000
2.80
0.695
3.889
1.59
79.3
1920 x
2090
1100 +
1100
955
12.06
3Ø + T
10000
3.10
0.695
3.889
1.91
77.9
1920 x
2090
1100 +
1100
955
12.06
3Ø + T
15000
3.80
0.834
5.000
1.65
79.5
2192 x
2340
1100 +
1200
1250
15.45
3Ø + T
15000
4.10
0.834
5.000
1.98
78.4
2192 x
2340
1100 +
1200
1250
15.45
3Ø + T
940
882
1.584
15.2
1150
1043
1.625
17.9
1407
1334
1.612
22.5
2070
1911
1.809
29.1
2576
2213
1.710
37.1
3014
2593
1.808
41.1
3631
3095
1.770
50.3
4109
3484
1.852
54.3
8,156 10,589 13,140 15,003 16,680 18,498 20,174 23,708 23,708 27,738 27,738
(2-row) (2-row) (2-row) (2-row)
Floway Classic cooling and heating/cooling only coil (2-row) - inside
Fan motor assembly supply
W
317
546
866
Fan motor assembly exhaust
W
266
473
715
Specific fan power
kW/m3s 1.945
1.852
1.756
Changeover coil capacity
kW
4.0
7.3
11.9
(heating)***
Changeover coil capacity
kW
5.7
10.5
17.1
(cooling)****
Price**
4000
1.15
0.25
1.583
1.16
78.8
1510 x
1659
800 +
800
558
4.23
3Ø + T
9,871 12,262 13,998 15,674 17,260 18,937 22,231 22,231 26,161 26,161
Floway Classic hot water coil (1-row) - inside the unit
Fan motor assembly supply
W
289
517
Fan motor assembly exhaust
W
266
473
Specific fan power
kW/m3s 1.850
1.798
Heating water coil capacity***
kW
4.0
7.3
Price**
3000
0.90
0.194
1.028
1.42
79.3
1210 x
1359
800 +
800
432
3.82
3Ø + T
the unit
997
1219
882
1043
1.633
1.676
15.2
17.9
21.9
25.7
1463
1334
1.645
22.5
2166
1911
1.853
29.1
2783
2213
1.784
37.1
3481
2593
1.959
41.1
4135
3095
1.903
50.3
4707
3484
1.998
54.3
32.3
41.8
52.2
58.9
72.2
77.9
8,355 10,764 13,340 15,196 16,862 18,801 20,398 23,788 23,788 27,818 27,818
* ERP regulation UE 1253/2014.
** Includes casing/heat recovery/control and display/set of fans/M5 and F7 filter/Modbus.
*** Capacity at (W 45-40°C).
****Capacity at (W 7-12°C).
45
A leader in Cooling, Heating and Indoor Air Quality
www.cdlweb.info
email: sales@cooldesignsltd.co.uk
tel.: 0191 549 6964
FLOWAY CLASSIC
Air handling unit accessories
Rotary heat exchanger
Accessories
Floway Classic
Description
Filter - F9 HEE
Water coil H & C/CO (4-row) - inside the unit
Water coil HO (1-row) - additional casing
Water coil H & C/CO (2-row) - additional casing
Water coil H & C/CO (3-row) - additional casing
Water coil H & C/CO (4-row) - additional casing
Electric heater (1-stage) – inside the unit
Electric heater (2-stage) – inside the unit
Electric heater (1-stage) – additional casing
Electric heater (2-stage) – additional casing
Motorised damper
Dimensions
Outdoor motorised damper
Dimensions
Flexible sleeve (intake OR discharge)
Dimensions
Partial mixing section
(internal recycling damper)
Total mixing section
(internal recycling + 2 external dampers)
Roof
Hood
Separator screen for hood
Adjustable feet
Quantity
Epoxy coating for rotary heat exchanger
Hygroscopic coating for rotary heat exchanger
Pre-painted fins on coils – 1-row
Pre-painted fins on coils – 2-row
Pre-painted fins on coils – 3-/4-row
Multi-units display (1-30) (display + TCONN card)
LON PCB
KNX PCB
Modbus TCP – BACnet IP PCB
∆P sensor for HR icing management
IAQ sensor kit (CO2)
Constant pressure management kit
Ambient in-room control kit
Smoke detector kit
RJ11 cable 10 m/50 m
1000
2000
3000
4000
5000
6000
7500
10000
15000
£
£
£
£
£
£
£
£
£
£
£
77
115
132
232
232
271
271
321
362
2,076
2,315
1,022
1,182
1,413
1,669
1,669
2,044
2,044
1,142
1,277
1,533
1,780
1,780
2,188
2,188
1,237
1,477
1,836
3,034
3,034
2,554
2,554
878
974
1,118
1,214
1,261
1,429
1,477
942
1,086
1,205
1,205
1,341
1,509
1,557
1,847
3,209
1,261
1,437
1,652
1,876
1,924
2,235
2,283
1,326
1,549
1,741
1,956
2,004
2,315
2,362
128
168
343
375
375
415
415
415
527
250 dia
355 dia 1150 x 560 1450 x 650 1450 x 650 1750 x 840 1750 x 840 1750 x 840 2010 x 880
296
312
343
375
375
415
415
415
527
£
mm 370 x 370 470 x 470 1150 x 560 1450 x 650 1450 x 650 1750 x 840 1750 x 840 1750 x 840 2010 x 880
17
20
76
91
91
112
112
112
128
£
mm 250 dia 355 dia 990 x 510 990 x 510 1290 x 610 1590 x 810 1590 x 810 1590 x 810 1900 x 810
200
224
271
296
296
319
319
527
575
£
£
790
846
958
1,046
1,046
1,149
1,149
1,357
1,629
£
£
£
£
346
184
28
64
4
231
152
6
11
19
359
280
280
359
119
559
203
184
319
14/53
363
200
44
96
6
352
191
11
20
33
359
280
280
359
119
559
203
184
319
14/53
389
228
80
128
8
471
231
13
33
39
359
280
280
359
119
559
203
184
319
14/53
449
256
96
128
8
567
263
26
51
102
359
280
280
359
119
559
203
184
319
14/53
449
256
96
128
8
655
335
26
51
102
359
280
280
359
119
559
203
184
319
14/53
518
287
119
128
8
767
375
42
82
125
359
280
280
359
119
559
203
184
319
14/53
518
287
119
128
8
1,022
487
42
82
125
359
280
280
359
119
559
203
184
319
14/53
583
359
168
128
8
1,261
583
95
188
359
280
280
359
119
559
203
184
319
14/53
647
447
200
128
8
1,676
734
128
256
359
280
280
359
119
559
203
184
319
14/53
£
£
£
£
£
£
£
£
£
£
£
£
£
£
£
46
A leader in Cooling, Heating and Indoor Air Quality
www.cdlweb.info
email: sales@cooldesignsltd.co.uk
tel.: 0191 549 6964
•
•
•
•
•
•
•
•
•
•
•
Counter flow ‘plug and play’ air handling unit.
Double filtration (F7 and F9).
Plate heat exchanger with variable speed.
Free cooling and night cooling management.
EC fan motor.
Electrical pre-heater available = -15°C heat recovery.
Casing mechanical strength = D2.
Air leakage (± pressure) = L2.
Air leakage filter assembly = F9.
Thermal transmittance = T3.
Thermal bridge = TB2.
Floway Classic
Air flow
Minimum air flow
Maximum air flow
V air filter section
Recovery efficiency EN308*
Width x height
Length
Weight
Supply power
Supply
FLOWAY CLASSIC
Air handling unit
Plate heat exchanger
m3/s
m3/s
m3/s
m/s
%
mm
mm
kg
kW
Phase
1000
0.30
0.083
0.333
1.21
81.0
810 x 958
1580
200
1.43
1Ø
2000
0.55
0.139
0.694
1.42
85.8
1010 x 1158
1150 + 800
350
2.50
3Ø + T
3000
0.90
0.194
1.028
1.42
85.2
1210 x 1359
1264 + 800
465
3.82
3Ø + T
4000
1.15
0.250
1.583
1.16
85.4
1510 x 1659
1264 + 800
580
4.23
3Ø + T
6000
1.70
0.389
2.361
1.18
84.7
1810 x 1959
1407 + 800
765
6.03
3Ø + T
£
7,517
9,871
12,262
13,998
17,260
Floway Classic hot water coil (1-row) - inside the unit
Fan motor assembly supply
W
284
Fan motor assembly exhaust
W
253
Specific fan power
kW/m3s
1.790
Heating water coil capacity***
kW
6.1
520
483
1.824
11.2
876
798
1.860
17.3
1010
941
1.697
23.5
1581
1517
1.822
34.7
10,589
13,140
15,003
18,498
933
798
1.923
17.3
17.1
1063
941
1.743
23.5
21.9
1637
1517
1.855
34.7
32.3
13,340
15,196
18,801
Price**
Price**
£
8,156
Floway Classic cooling and heating/cooling only coil (2-row) - inside the unit
Fan motor assembly supply
W
312
550
Fan motor assembly exhaust
W
253
483
Specific fan power
kW/m3s
1.881
1.878
Changeover coil capacity (heating)***
kW
6.1
11.2
Changeover coil capacity (cooling)***
kW
5.7
10.5
Price**
£
8,355
10,764
* ERP regulation UE 1253/2014.
** Includes casing/heat recovery/control and display/set of fans/M5 and F7 filter/Modbus.
*** EN308 conditions: Dry performance, altitude 0 m, iso air flow: Fresh air 5°C/80%; Exhaust air 25°C/27%.
47
A leader in Cooling, Heating and Indoor Air Quality
www.cdlweb.info
email: sales@cooldesignsltd.co.uk
tel.: 0191 549 6964
FLOWAY CLASSIC
Air handling unit accessories
Plate heat exchanger
Accessories
Floway Classic
Description
Filter - F9 HEE
Water coil HO (1-row) - additional casing
Water coil H & C/CO (2-row) - additional casing
Water coil H & C/CO (3-row) - additional casing
Water coil H & C/CO (4-row) - additional casing
Electric heater (1-stage) – inside the unit
Electric heater (2-stage) – inside the unit
Electric pre-heater (1-stage) – inside the unit
Electric heater (1-stage) – additional casing
Electric heater (2-stage) – additional casing
Motorised damper
Dimensions, mm
Outdoor motorised damper
Dimensions, mm
Flexible sleeve (intake OR discharge)
Dimensions, mm
Roof
Hood
Separator screen for hood
Adjustable feet
Quantity
Epoxy coating for plate heat exchanger
Pre-painted fins on coils – 1-row
Pre-painted fins on coils – 2-row
Pre-painted fins on coils – 3-/4-row
Multi-units display (1-30) (display + TCONN card)
LON PCB
KNX PCB
Modbus TCP – BACnet IP PCB
∆P sensor for HR icing management
IAQ sensor kit (CO2)
Constant pressure management kit
Ambient in-room control kit
Smoke detector kit
RJ11 cable 10 m/50 m
£
£
£
£
£
£
£
£
£
£
£
mm
£
mm
£
mm
£
£
£
£
£
£
£
£
£
£
£
£
£
£
£
£
£
£
1000
2000
3000
4000
6000
77
1,022
1,142
1,261
878
942
1,009
1,261
1,326
128
250 dia
296
370 x 370
17
250 dia
346
184
28
64
4
231
6
11
19
359
280
280
359
119
559
203
184
319
14/53
115
1,182
1,277
1,437
974
1,086
1,149
1,437
1,549
168
355 dia
312
470 x 470
20
355 dia
363
200
44
96
6
352
11
20
33
359
280
280
359
119
559
203
184
319
14/53
132
1,413
1,533
1,836
1,118
1,205
1,322
1,652
1,741
343
1150 x 560
343
1150 x 560
76
990 x 510
389
228
80
128
8
526
13
33
39
359
280
280
359
119
559
203
184
319
14/53
232
1,669
1,780
2,554
1,214
1,205
1,501
1,876
1,956
375
1450 x 650
375
1450 x 650
91
990 x 510
449
256
96
128
8
706
26
51
102
359
280
280
359
119
559
203
184
319
14/53
271
2,044
2,188
3,034
1,429
1,509
1,788
2,315
2,315
415
1750 x 840
415
1750 x 840
112
1590 x 810
518
287
119
128
8
1,099
42
82
125
359
280
280
359
119
559
203
184
319
14/53
48
A leader in Cooling, Heating and Indoor Air Quality
www.cdlweb.info
email: sales@cooldesignsltd.co.uk
tel.: 0191 549 6964
•
•
•
•
•
•
•
•
•
•
•
FLOWAY VERTICAL
Air handling unit
Self-supporting construction.
Double-wall casing with 50 mm insulation.
Pre-lacquered outer panel, galvanized inner panel.
Panel colour RAL 7035 and RAL 7024.
Fire rating A1/M0.
Air speed 300-2,600 m3/h.
Wide range of options available.
For indoor use with compact unit dimensions.
Plug fan with brushless EC motor.
Carel pC03 controller included.
Counter-flow heat exchanger.
Floway Vertical
Minimum air flow
Maximum air flow
Maximum power input
Maximum current
Width x height
Length
Weight
Power supply
m3/h
m3/h
kW
A
mm
mm
kg
V/ph/Hz
Floway Classic Vertical
Plate heat exchanger with variable speed M5 and F7, plate heat exchanger, EC plug fan, Modbus, display
Price
£
Accessories
Description
Intake motorised damper
Flexible intake sleeve
Built-in single-stage electric heater
Built-in 1-row heating coil with valves
External single-stage electric heater
External 1-row heating coil with valves
External 2-row heating/cooling coil with valves
External 3-row heating/cooling coil with valves
700
300
1200
1.43
6.2
700 x 1340
1272
202
220-240/1/50
1500
700
2000
2.50
3.6
800 x 1712
1550
330
380-415/3/50
7,279
2000
700
2600
2.50
3.6
800 x 1854
1692
389
380-415/3/50
9,125
£
£
£
£
£
£
£
£
10,382
Size 700
Size 1500
Size 2000
128
17
671
671
1,261
1,248
1,142
1,237
168
20
886
702
1,4137
1,182
1,277
1,477
168
20
1,078
734
1,437
1,182
1,277
1,477
49
A leader in Cooling, Heating and Indoor Air Quality
www.cdlweb.info
email: sales@cooldesignsltd.co.uk
tel.: 0191 549 6964
FLOWAY CEILING
Air handling unit
•
•
•
•
•
•
•
•
•
•
•
Self-supporting construction.
Double-wall casing with 50 mm insulation.
Pre-lacquered outer panel, galvanized inner panel.
Panel colour RAL 7035 and RAL 7024.
Fire rating A1/M0.
Air speed 300-1,900 m3/h.
Wide range of options available.
For indoor use with compact unit dimensions.
Plug fan with brushless EC motor.
Carel pC03 controller included.
Counter-flow heat exchanger.
Floway Ceiling
Minimum air flow
Maximum air flow
Maximum power input
Maximum current
Width x height
Length
Weight
Power supply
m3/h
m3/h
kW
A
mm
mm
kg
V/ph/Hz
Floway Classic Hot Water Coil
Plate heat exchanger with variable speed M5 and F7, plate heat exchanger, EC plug fan, Modbus, display
Price
£
Accessories
Description
Intake motorised damper
Flexible intake sleeve
External single-stage electric heater
External 1-row heating coil with valves
External 2-row cooling coil with valves
External 3-row heating/cooling coil with valves
700
300
1000
1.43
6.2
896 x 557
1359
161
220-240/1/50
1200
500
1400
1.43
6.2
1174 x 557
1498
206
220-240/1/50
6,646
1600
600
1900
2.50
3.6
1456 x 557
1762
279
380-415/3/50
8,528
£
£
£
£
£
£
9,958
Size 700
Size 1200
Size 1600
202
29
1,261
1,022
1,142
1,237
223
33
1,341
1,182
1,277
1,477
223
33
1,413
1,182
1,277
1,477
50
A leader in Cooling, Heating and Indoor Air Quality
www.cdlweb.info
email: sales@cooldesignsltd.co.uk
tel.: 0191 549 6964
• Indirect-fired air heater and/or air chiller.
• Fan motor with ROTOREX technology for efficient air flow
and quiet operation.
• Double distributor with standard JET+ technology.
• One unit model for both vertical and horizontal usage.
• Highly efficient heat exchanger.
• Built-in antibacteria condensate drain pan with paddle
connectors for cooling or reversible heating operation.
• Wide choice of accessories.
• Comprehensive range of controls for each operation (on/off,
proportional, electric heater, etc.).
• Optional unit available with energy-efficient HEE motor.
HELIOTHERME 4000
Air heater/chiller
For heating (power supply 230 V - 1 ph - 50/60 Hz)
Unit
No. of rows
Power
Air speed
Air throw
Part Number
Total price, £
W
m3/h
m
4350
1
13900
2600
22
B400000, B400074, B400025
492
2
24800
2400
20
B400000, B400074, B400026
541
3
30100
2075
15
B400000, B400074, B400027
591
4400
1
20200
4200
26
B400005, B400078, B400034
603
2
37100
3800
23
B400005, B400078, B400035
651
3
46500
3450
23
B400005, B400078, B400036
704
4450
1
27300
5200
27
B400010, B400082, B400043
687
2
48500
4700
21
B400010, B400082, B400044
754
3
63000
4550
18
B400010, B400082, B400045
813
4500
1
36300
7100
28
B400015, B400086, B400052
829
2
65500
6600
26
B400015, B400086, B400053
922
3
85900
6200
24
B400015, B400086, B400054
1,004
4630
1
53200
10450
28
B400020, B400090, B400061
1,095
2
97900
9610
24
B400020, B400090, B400062
1,202
3
122000
8280
21
B400020, B400090, B400063
1,298
The above units are also available with 400 V power supply. The heating capacities and air flows will vary. Please contact us for more information.
For cooling (power supply 230 V - 1 ph - 50/60 Hz)
Unit
No. of rows
Power
W
4350
3
4780
4400
3
6680
4450
3
10100
4500
3
13800
4630
3
21400
Air speed
m3/h
1640
2160
3025
4060
5960
Air throw
m
23
26
24
23
21
Part Number
B400000,
B400005,
B400010,
B400015,
B400020,
B400076,
B400080,
B400084,
B400088,
B400092,
B400027
B400036
B400045
B400054
B400063
Total price, £
591
704
832
1,026
1,292
Available unit options
Description
Part Number
Total price, £
Wall mounting/ceiling mounting kit
7181226/7185116
53/45
5-speed transformer kit
7166982
117
The above capabilities are based on Eurovent conditions. For cooling with an air inlet temperature of 25°C/50% RH and a water range of 7-12°C,
heating with an air inlet temperature of 15°C/50% RH and a water range of 90-70°C at high fan speed. CIAT participates in the Eurovent certification
program. For a list of products and certified characteristics, please refer to www.eurovent-certification.com.
51
A leader in Cooling, Heating and Indoor Air Quality
New
product
launch
July 2017
www.cdlweb.info
email: sales@cooldesignsltd.co.uk
tel.: 0191 549 6964
SPACE
Packaged unit
• High efficiency cooling circuits for R410A with
electronic expansion valves and scroll compressor.
• Electronic axial fans for low noise level.
• Multiple recovery options on the extracted air energy.
• Heating back-up options: electric heaters, hot water
coil, gas burner or boiler.
• Plug-fans (free-wheel) with EC motors.
• Available as Cooling Only, Heat Pump, Heat Recovery
models.
Space
IPJ
Cooling capacity
kW
Power input
kW
EER
Heating capcaity
kW
Power input
kW
COP
Outdoor circuit fan air flow
m3/h
Available static pressure
Pa
Indoor circuit supply fan air flow
m3/h
Available static pressure
Pa
Power supply
V/ph/Hz
Maximum absorbed current
A
Refrigerant charge
kg
Weight
kg
Sound power level
dB(A)
90
22.5
7.3
3.10
22.0
6.0
3.67
9.0
49
5.1
117
120
28.3
9.4
3.01
28.1
8.0
3.50
14.5
49
6.5
117
140
34.7
11.0
3.16
33.7
9.6
3.53
17.0
49
8.7
117
160
38.6
12.6
3.06
38.2
10.9
3.50
17.0
49
9.25
147
180
42.9
14.2
3.01
42.4
12.3
3.44
17.0
49
9.45
147
18.5
6.7
585
71
26.5
7.0
610
80
30.5
11.0
675
80
33.5
11.0
680
84
Price
TBC
TBC
TBC
TBC
£
190
45.5
15.1
3.01
45.3
13.3
3.41
17.8
49
9.45
147
220
57.7
19.1
3.03
56.7
16.6
3.42
31.0
49
12.5
196
240
60.3
20.1
3.01
59.5
17.4
3.41
31.0
49
12.5
196
280
67.7
21.9
3.09
67.9
19.5
3.49
33.0
49
16
196
320
71.3
23.4
3.05
72.2
20.9
3.45
33.0
49
16
196
360
80.2
26.4
3.04
80.8
23.6
3.43
34.5
49
16.5
245
380
90.0
29.9
3.01
90.9
26.7
3.41
35.0
49
16.5
245
37.5
11.5
685
85
200
53.1
17.2
3.09
51.5
15.0
3.44
31.0
49
12
196
415/3/50
38.0
44.3
11.5
12.5
690
990
85
85
49.9
12.5
995
85
50.1
13.0
1040
85
50.2
19.5
1155
85
53.7
19.5
1160
85
62.3
20.0
1165
86
67.5
20.0
1170
86
TBC
TBC
TBC
TBC
TBC
TBC
TBC
TBC
TBC
Cooling capacity in accordance with EN-14511-2013 for indoor temperature conditions 27ºC,19ºC WB and 35ºC outdoor temperature.
Heating capacity in accordance with EN-14511-2013 for indoor temperature conditions 20ºC and 6ºC WB outdoor temperature.
Total power input by compressor and motorised fans under nominal conditions in accordance with EN-14511-2013.
52
A leader in Cooling, Heating and Indoor Air Quality
www.cdlweb.info
email: sales@cooldesignsltd.co.uk
tel.: 0191 549 6964
SPACE
Packaged unit options and accessories
Family
Electrical power
Flow and
assembly
Coil coating
Heating
Protection low
temperature
Indoor fan
Air filtration and
stop-drop
Outdoor fan
Insulation
Indoor unit
Outdoor unit
Passive recovery
Probes
Free-cooling and
outdoor humidity
Terminal and unit
communication
Miscellaneous
item 1
Miscellaneous
item 2
Roofcurb
* The gas burner is
Description
In factory On site Price, £
400 V/3 ph/50 Hz (without neutral)
✓
TBC
CS: Cross flow with 2 dampers
✓
TBC
CK: Cross flow with 3 dampers
✓
TBC
CA: Cross flow with axial return fan
✓
TBC
CP: Cross flow with lower return plug-fan
✓
TBC
CQ: Cross flow with upper return plug-fan
✓
TBC
CW: Cross flow with passive recovery
✓
TBC
TS: Tunnel flow with 2 dampers (for models 0200 to 0380)
✓
TBC
TP: Tunnel flow with return plug-fan (for models 0200 to 0380)
✓
TBC
TW: Tunnel flow with passive recovery (for models 0200 to 0380)
✓
TBC
Coil with copper pipes and copper fins
✓
TBC
Coil with copper pipes and fins of an aluminium alloy (INERA®)
✓
TBC
Coil with copper pipes and aluminium fins with polyurethane coating
✓
TBC
Coil with copper pipes and aluminium fins with Blygold® coating
✓
TBC
Auxiliary hot water coil: standard or great cold
✓
✓
TBC
Auxiliary electrical heaters
✓
✓
TBC
Natural or propane gas burner
✓*
TBC
Gas boiler and auxiliary hot water coil
✓
TBC
Antifreeze protection kit for low temperature (<-10ºC)
✓
TBC
Antifreeze protection kit for low temperature (<-14ºC)
✓
TBC
High available pressure of the indoor fan
✓
TBC
Low available pressure of the indoor fan
✓
TBC
Stop-drop in the indoor air coil
✓
✓
TBC
Gravimetric filters G4 with low pressure drop
✓
✓
TBC
Gravimetric filters G4 + folded opacimetric filters M6, F7 or F9
✓
✓
TBC
Gravimetric filters G4 low pressure drop + folded opacimetric filters F7 or F9
✓
✓
TBC
Double stage of folded opacimetric filters (M6+F7, M6+F9, F7+F9 or F9+F9)
✓
✓
TBC
Axial 2-speed outdoor fan(s) directly coupled to the motor
✓
TBC
Ceramic fibre for thermal and acoustic insulation, Euroclass A2-s1, d0 (M0)
✓
TBC
Condensate drain pan in stainless steel
✓
✓
TBC
Management of the overpressure
✓
TBC
Differential pressostat for the detection of clogged filters
✓
✓
TBC
Outdoor coil protective grille
✓
✓
TBC
Stop-drop at the fresh air intake
✓
✓
TBC
Anti-vibration mounts made of rubber
✓
✓
TBC
Rotary heat exchanger with CW assembly
✓
TBC
Rotary heat exchanger with TW assembly
✓
TBC
Ambient temperature probe: one NTC probe connected to the control board or one to four probes
✓
✓
TBC
with RS485 communication
Ambient temperatute and humidity probe: one to four probes with RS485 communication
✓
✓
TBC
CO2 air quality probe environment installed, duct-mounted or installed on a pLAN local network
✓
✓
TBC
Smoke detecting station in accordance with the NF S 61-961 standard
✓
✓
TBC
Type of free-cooling: thermal, enthalpic or thermoenthalpic
✓
✓
TBC
Outdoor air humidity probe: supplied with the unit or installed on a pLAN local network
✓
✓
TBC
User terminal installed on the electric panel
✓
✓
TBC
User terminal installed on the electric panel + graphic terminal remote up to 50 m or 200 m
✓
✓
TBC
User terminal installed on the electric panel + graphic terminal remote up to 200 m
✓
✓
TBC
Unit configuration: stand-alone, master or slave
✓
✓
TBC
Communication cards: RS485 Modbus/Carel; Ethernet PCoWeb; RS485 LonWorks®; Ethernet
✓
✓
TBC
BACnetTM; RS485 BACnetTM; RS485 Konnex
Management of an humidifier with proportional or on/off control
✓
✓
TBC
Energy meter
✓
✓
TBC
Energy meter and calculation of the cooling and heating capacities
✓
✓
TBC
Compressor soft starter
✓
✓
TBC
Tropicalised components on the electric panel: control board, cards and terminals
✓
TBC
High performance phase monitoring relay
✓
TBC
High performance magnetothermic switches
✓
TBC
Standardised pre-assembly roofcurbs with adjustable height (cross flow)
✓
TBC
Adaptation roofcurbs for replacing units on site (tunnel flow)
✓
TBC
supplied installed into a pre-assembly roofcurb.
53
A leader in Cooling, Heating and Indoor Air Quality
www.cdlweb.info
email: sales@cooldesignsltd.co.uk
tel.: 0191 549 6964
Air product range of equipment
AIR COMPACT
FLOWAY
CLIMACIAT
Water-Cooled/Heated Internal AHU
Plug & Play, Internal/External AHU
Bespoke AHUs for all applications including
HTM 03 01
Air flow rates: up to 1.66 m3/s
Air flow rates: 0.13 to 5 m3/s
Air flow rates: 2.8 to 7 m3/s
SPACE
EXPAIR/MAGISTER
Roof Top Packaged Units
Close Control Units
MAJOR/COMFORT LINE
COADIS/MELODY CASSETTE
Heating capacity: 20 and 286 kW
Cooling capacity: 19 and 277 kW
Air flow rates: up to 12.8 m3/s
Cooling capacity: 5 to 130 kW
Air flow rates: 0.28 to 3.35 m3/s
Heating capacity: 20 and 286 kW
Cooling capacity: 19 and 277 kW
Air flow rates: up to 12.8 m3/s
HELIOTHERME
AIRDUO/NEXIA/NEPTUS
AQUAIR/AIRMASTER
Air Heaters and Coolers, many versions
and applications
Packaged Internal and Split Type Systems
Swimming Pool and
Dehumidification Systems
Heating capacity: 7 and 110 kW
Cooling capacity: 8 and 92 kW
Air flow rates: 0.04 to 4.7 m3/s
Heating capacity: 21 to 144.5 kW
Cooling capacity: 19 to 135 kW
Air flow rates: up to 5.7 m3/s
Heating capacity: 69 and 148 kW
Cooling capacity: 92 and 148 kW
Water removal capacity: 4 to 120 kg/h
Fan Coils for every application
54
A leader in Cooling, Heating and Indoor Air Quality
Chiller and heat pump range of equipment
www.cdlweb.info
email: sales@cooldesignsltd.co.uk
tel.: 0191 549 6964
AQUACIAT
AQUACIAT power
POWERCIAT
Air-Cooled HP Water Chiller
Air-Cooled HP Water Chiller
Air-Cooled Water Chiller
Heating capacity: 42 to 162 kW
Cooling capacity: 38 to 160 kW
R410A scroll compressor
Heating capacity: 190 to 500 kW
Cooling capacity: 190 to 640 kW
R410A scroll compressor
Cooling capacity: 600 to 1350 kW
R134A screw compressor
DYNACIAT
DYNACIAT power
HYDROCIAT
Water-Cooled Heat Pump/Chiller
Water-Cooled Heat Pump/Chiller
Water-Cooled Heat Pump/Chiller
Heating capacity: 40 to 210 kW
Cooling capacity: 35 to 180 kW
R410A scroll compressors
Heating capacity: 250 to 820 kW
Cooling capacity: 220 to 720 kW
R410A scroll compressors
Heating capacity: 500 to 1400 kW
Cooling capacity: 370 to 1170 kW
R134A screw compressors
VEXTRA/OPERA
EREBA
YUNA II
Air-Cooled Dry Cooler/Condenser
Comprehensive Range of
Reversible Heat Pumps
Packaged Hot Water System with Buffer
Tank/Expansion Vessel/Heat Exchanger
Cooling capacity: 8 to 1350 kW
Extensive range of over 4500 models
Heating capacity: 4 to 40 kW
Cooling capacity: 4 to 40 kW
Air-cooled rotary and inverters
Heating capacity: 4 to 15 kW
Energy Class A++
55
A leader in Cooling, Heating and Indoor Air Quality
www.cdlweb.info
email: sales@cooldesignsltd.co.uk
tel.: 0191 549 6964
Toshiba range of products and services
RAS Split-System
RAS Multi Split-System
Estía Air-to-Water Heat Pump
Residential Range
Residential Range
Hot Water System
Heating capacity: 2 to 5.8 kW
Cooling capacity: 1.5 to 5 kW
Heating capacity: 4.4 to 12 kW
Cooling capacity: 4 to 10 kW
Heating capacity: 8 to 16 kW
Water storage volume: 150 to 300 l
Electric heater: 2.75 kW
RAV Digital Inverter
RAV Super Digital Inverter
VRF
Light Commercial Range
(Compact and Lightweight Outdoor Units)
Light Commercial Range
(Longer Pipe Runs and Higher Efficiency)
VRF Indoor Units
Heating capacity: 3.4 to 27 kW
Cooling capacity: 2.5 to 23.7 kW
Heating capacity: 3.4 to 27 kW
Cooling capacity: 2.5 to 23.7 kW
Heating capacity: 1.9 and 31.5 kW
Cooling capacity: 1.7 and 28 kW
Mini VRF Outdoor Unit
VRF Outdoor Unit
VRF High-Efficiency Outdoor Unit
MiNi-SMMSe - VRF 2-Pipe Heat Pump
SMMSe - VRF 2-Pipe Heat Pump
SMMSe - VRF 2-Pipe High-Efficiency
Heat Pump
Heating capacity: 12.5 to 18 kW
Cooling capacity: 12.1 and 15.5 kW
Heating capacity: 25 to 178 kW
Cooling capacity: 22.4 to 168 kW
Heating capacity: 63 to 171 kW
Cooling capacity: 56 to 152 kW
56
A leader in Cooling, Heating and Indoor Air Quality
Toshiba range of products and services
www.cdlweb.info
email: sales@cooldesignsltd.co.uk
tel.: 0191 549 6964
VRF Heat Recovery Outdoor Unit
VRF Flow Selector Boxes
VN Units (Air-to-Air Heat Exchangers)
SHRMe - VRF 3-Pipe Heat Recovery Unit
SHRMe - 3-Pipe Heat Recovery Units
Standard with DX Coil and/or Humidifier
Heating capacity: 25 to 135 kW
Cooling capacity: 22.4 to 120 kW
Standard and Premium Single-Port Box
4- and 6-Way Multi-Port Box
Heating capacity: 5.53 to 10.92 kW
Cooling capacity: 4.10 to 8.25 kW
Air flow: 150 to 2000 m3/h
RAV and VRF
DX Air Curtains
Pre-Sales Support
Air Handling Application DX Coils
Split-System and VRF
Full Design and Support Service
Heating capacity: 3.4 to 178 kW
Cooling capacity: 2.5 to 168 kW
Heating capacity: 8 to 16 kW
Door width: 1 m, 2 m and 2.5 m
Technical Support
Toshiba Rewards Scheme
Extended Warranty
24/7/364 Technical Support
The Original and Best Reward Scheme
Designed to Reward Competence
57
A leader in Cooling, Heating and Indoor Air Quality
When building and HVAC equipment or controls are not serviced or maintained
your business is at risk
Service and maintenance is a year-round necessity in order to optimise efficiency, save money, help to make sound
management decisions and free you from the anxiety of unplanned downtime.
With a CIAT maintenance contract you ensure regular service and maintenance requirements are met and you avoid the
adverse consequences of neglect. CIAT makes it easy for you to select a level of service that’s right for your operation.
CIAT engineers are highly-skilled in all building systems assessment. They have access to advanced diagnostic tools and
analysis software, which will quickly and accurately evaluate your entire infrastructure and identify opportunities for
improvements and cost-savings.
Our engineers are industry-served, which gives CIAT the ability to service and maintain equipment from any manufacturer.
CIAT is one of the best-trained service providers in the industry. Our engineers are trained on the most up-to-date
factory developments and all our engineers have to pass stringent health and safety tests along with ethics training.
Commissioning
We provide a full commissioning service carried out by professionally-trained, experienced engineers to ensure that
once acquired, your equipment is set up to function correctly and efficiently in order to optimise its performance.
Commissioning service engineers
When choosing to use our commissioning service you can rest assured that all of our commissioning service engineers are:
• Factory-trained to the highest standards by senior engineers who are involved in the actual design of the equipment.
• Fully-equipped with the required test instruments (fully-calibrated with certification available on request).
• Equipped with laptops and the software necessary to communicate with our controllers and unit strategies.
On-site instruction
In addition to our commissioning service we can also provide commissioning engineers for on-site instruction. This is
useful for those responsible for day-to-day unit operation (if not already covered by a CIAT Service and Maintenance
contract). Although this service is tailored to individual needs, it would typically include the following:
• Provision of the controls and operating and maintenance manuals. Introduction to the content of these manuals,
allowing you to highlight what you feel to be relevant.
• Basic navigation and explanation of the controller operation and alarm handling.
• Discussion about the general maintenance of the unit, covering mechanical items such as belts, motors and
electrical items, e.g. the humidifier and electrical panel.
58
A leader in Cooling, Heating and Indoor Air Quality
WARRANTY AND MAINTENANCE
2-Year Enhanced
• CIAT Commission.
• CIAT Maintenance.
Standard warranty is 12 months. Extended warranty must be
activated within 30 days of system commissioning.
Thanks to CIAT M2M, you can monitor and control the correct
operation of your installation remotely. This service improves the
performance of your equipment, optimises its use and provides
you with technical support from our experts in real time.
3-Year Enhanced
• CIAT Commission.
• CIAT Maintenance.
5-Year Comprehensive
• CIAT Commission.
• CIAT Maintenance.
• Remote Monitoring.
• Available on selected sites only.
AHU FLAT PACK
• Restrictive site access solutions can be achieved with CIAT
Ozonair’s AHU flat pack service.
• Where access to a plant area is restricted CIAT Ozonair
engineers can either off-load and build as required or build
units placed in situ by others.
• This approach can help minimise disruption on site and to
the customer.
• Flat pack installation of air handling units and other CIAT
Ozonair products can also save costs on builders’ work,
crane hire and potential road closures.
AHU AND PACKAGED AC REFURBISHMENT
• Practical alternative to replacing with new equipment.
• Cost of refurbishment can save between 50 and 65% of system replacement cost, as well as offer savings in time and expense by obviating the
need for lifting equipment and potential road closures.
• Itemised quotations, to enable essential works to be carried out first,
followed by staged improvement works to the equipment.
• Staged and scheduled works to reduce disruption to the client and help
with budgetary requirements.
• Reduce running costs by installing more efficient components.
• Services include replacement of casework, gas burners, cooling coils,
heat recovery, higher grade filtration or upgrading fan performance.
59
A leader in Cooling, Heating and Indoor Air Quality
Download PDF