Intellinder™ Feedback Device - Parker Cylinder Distributor

aerospace
climate control
electromechanical
filtration
fluid & gas handling
hydraulics
pneumatics
process control
sealing & shielding
Intellinder™ Feedback Device
Installation Instructions for use
with Analog Out Modules
Bulletin HY08-0880-M1
Intellinder™ Feedback Device
Installation Instructions for Analog Out Modules
In line with our policy of continuing product improvement, specifications and information contained in this bulletin are subject to change.
Copyright ©2014 by Parker Hannifin Corporation. All rights reserved.
PRINTED IN THE U.S.A.
WARNING
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH,
PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from the Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation
by users having expertise. It is important that you analyze all aspects of your application, including consequences of any failure and review the information concerning the product
or system in the current product catalog. Due to the variety of operating conditions and applications for these products or systems, the user, through its own analysis and testing,
is solely responsible for making the final selection of the products and systems and assuring that all performance, safety and warning requirements of the application are met.
The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by Parker Hannifin
Corporation and its subsidiaries at any time without notice.
Offer of Sale
The items described in this document are hereby offered for sale by Parker Hannifin Corporation, its subsidiaries or its authorized
distributors. This offer and its acceptance are governed by provisions stated on a separate page of the document entitled ‘Offer of Sale’.
www.parker.com/cylinder
Parker Hannifin Corporation
Industrial Cylinder Division
Des Plaines, Illinois USA
Bulletin HY08-0880-M1
Table of Contents
Intellinder™ Feedback Device
Installation Instructions for Analog Out Modules
Table of Contents
Hardware
2
Basic Intellinder Connection
3
Analog Output Wiring Detail
4
Programming & Diagnostic installation
5
Accessories Part Number
6
Programming Module
Main Page
7
Pin Codes
8
Set Up Page
9
Change Analog Output Type
10
Zero & Span
11
1
www.parker.com/cylinder
Parker Hannifin Corporation
Industrial Cylinder Division
Des Plaines, Illinois USA
Intellinder™ Feedback Device
Installation Instructions for Analog Out Modules
Bulletin HY08-0880-M1
Hardware
Hardware
A
C
B
E
F
D
H
G
Item
I
Description
A
2HX cylinder, with Intellinder feedback, 360° etching
B
Cylinder ID cable, M12 5 pin
C
CAN bus Y cable assembly
D
Analog Output Module (AOM)
E
AOM connection cable
F
MD3 Calibration Module
G
MD3 programming cable
H
Power/output cable
I
CAN bus extension cable
2
www.parker.com/cylinder
Parker Hannifin Corporation
Industrial Cylinder Division
Des Plaines, Illinois USA
Intellinder™ Feedback Device
Installation Instructions for Analog Out Modules
Bulletin HY08-0880-M1
Basic Intellinder Connection
Basic Intellinder Connection
H
F
B
G
I
A
E
D
Item
Description
A
2HX Cylinder, with Intellinder Feedback, 360° etching
B
Cylinder ID Cable, M12 5 pin
D
Analog Output Module (AOM)
E
AOM Connection Cable
F
MD3 Calibration Module
G
MD3 Programming Cable
H
Power/Output Cable
I
CAN bus Extension Cable
3
www.parker.com/cylinder
Parker Hannifin Corporation
Industrial Cylinder Division
Des Plaines, Illinois USA
Bulletin HY08-0880-M1
Wiring Detail
Intellinder™ Feedback Device
Installation Instructions for Analog Out Modules
Analog Output Connection Cable – Wiring Detail
Power Cable Connection:
Male M12 Connector
CAN bus Cable Connection:
Female M12 Connector
AOM Connection Cable
Power Cable (male)
4
3
5
1
2
Pin Wire Color
Description
1
Brown
Power (+)
2
White
Analog Common
3
Blue
Power Common
4
Black
Analog Out
5
Gray
N/C
CAN Cable (female)
3
4
5
2
1
Pin Wire Color
1
Brown
2
White
3
Blue
4
Black
5
Gray
Description
Power (+)
N/C
Power Common
CAN H
CAN L
Power Cable wire color descriptions
Power Cable (male)
4
3
5
1
4
www.parker.com/cylinder
2
Pin
1
2
3
4
5
Wire Color
Brown
White
Blue
Black
Gray
Description
Power (+)
Analog Common
Power Common
Analog Out
N/C
Parker Hannifin Corporation
Industrial Cylinder Division
Des Plaines, Illinois USA
Intellinder™ Feedback Device
Installation Instructions for Analog Out Modules
Bulletin HY08-0880-M1
Diagnostic and Programming
Configuration for Diagnostic and Programming
G
H
F
I
C
B
E
A
D
Item
Description
A
2HX Cylinder, with Intellinder Feedback, 360° etching
B
Cylinder ID Cable, M12 5 pin
C
CAN bus Y cable assembly
D
Analog Output Module (AOM)
E
AOM Connection Cable
F
MD3 Calibration Module
G
MD3 Programming Cable
H
Power/Output Cable
I
CAN bus Extension Cable
5
www.parker.com/cylinder
Parker Hannifin Corporation
Industrial Cylinder Division
Des Plaines, Illinois USA
Intellinder™ Feedback Device
Installation Instructions for Analog Out Modules
Bulletin HY08-0880-M1
NEED HEADING
Configuration for Diagnostic and Programming
By adding the CAN bus Y connector to the CAN
bus cable assembly we can “tap” into the bus
communication and check the status of the Intellinder
reader and quality of the bar code image.
to provide diagnostic information of your positioning
system. It also provides the user flexibility to change the
output type from Voltage (0-10 V) to Current (4-20 mA)
and vice versa. Zero and Span are also available for
adjustment with the use of this accessory.
The MD3 Calibration Module supplied by Parker
Hannifin Industrial Cylinder Division is fully programed
Should this text be with previous page?
Accessories Part Numbers
Part Number
Description
0975510000
Programming/Calibration Module (Md3)
0975520000
Programming Cable
0975530000
Single Axis Analog Output Module
0975540000
4 Axis Analog Output Module
0975550000
4 Axis Cable, Id 0
0975560000
4 Axis Cable, Id 1
0975570000
4 Axis Cable, Id 2
0975580000
4 Axis Cable, Id 3
0975590000
4 Axis Cable, Id 4
0975600000
4 Axis Cable, Id 5
0975610000
4 Axis Cable, Id 6
0975620000
4 Axis Cable, Id 7
0975630000
M12, 5 Pin Cable, 5 Meters, Male/Female Straight
0975640000
M12, 5 Pin Cable, 10 Meters, Male/Female Straight
0975650000
M12, 5 Pin Cable, 5 Meters, Female/Flying Lead
0975660000
M12, 5 Pin Cable, 5 Meters, Female/Female
0975670000
M12, 8 Pin Cable, 5 Meters, Female/Flying Lead
0975680000
CAN Y Junction Cable
0975690000
Ethernet IP/TCP Gateway
0975700000
Profibus Gateway
0975710000
Modbus RTU Gateway
6
www.parker.com/cylinder
Parker Hannifin Corporation
Industrial Cylinder Division
Des Plaines, Illinois USA
Intellinder™ Feedback Device
Installation Instructions for Analog Out Modules
Bulletin HY08-0880-M1
MD3 Calibration Module
MD3 Calibration Module Screen Descriptions
1
2
6
3
5
4
Upon Power-up the above display we be active on the
MD3 Programming unit. The bar coded position data
will be displayed in the Position Value Field . Units
are in “inch”, with a resolution of 0.001". You may “zero”
the display by pressing the F2 key . Please note: This
will not zero your analog out, it will only zero the display.
This value (offset) is retained in memory and will display
the offset position value when power is toggled. This
field reads the value of the cylinder position over the
CAN, we will discuss zeroing the analog output later in
this document.
Image Quality : This bar represents the quality of the
bar code etched on the cylinder rod.
States are:
“Good”, green bar, text, signal at high strength.
“Medium” yellow bar, text, lower signal strength, no
errors encountered.
“Fair” amber bar, text, some errors detected, but
corrected by sensor.
“Critical” red bar, text, errors present positional data
suspect.
Output type : The configuration of Analog Output
module is displayed. Voltage output (0-10 V) or Current
(4-20 mA) are the  offerings. To refresh this value,
press the OK button .
Lock : Analog output module and Intellinder reader
set up and configuration screens are pin code protected.
Pressing the F4 button will prompt user to enter pin
code.
7
www.parker.com/cylinder
Parker Hannifin Corporation
Industrial Cylinder Division
Des Plaines, Illinois USA
Intellinder™ Feedback Device
Installation Instructions for Analog Out Modules
Bulletin HY08-0880-M1
Pin Codes
MD3 Calibration Module Screen Descriptions – Pin Codes
Use the Up & Down arrow
button to enter pin code.
Default Pin Code is 1111
After proper pin code is
entered, you will notice the
unit is Unlocked  and the
Set Mode F3 key is now
active .
After 1 minute the program
lock will be reset.
The program will allow you
to stay on the appropriate
configuration page, when
returned to home screen
application will be locked.
7
8
8
www.parker.com/cylinder
Parker Hannifin Corporation
Industrial Cylinder Division
Des Plaines, Illinois USA
Intellinder™ Feedback Device
Installation Instructions for Analog Out Modules
Bulletin HY08-0880-M1
Set Up Mode
MD3 Calibration Module Screen Descriptions – Set Up Mode
9
6
10
11
13
12
2HX Code: Ordering code for the Intellinder
configuration.
When entering into setup mode, special attention should
be made to the control of the cylinder. This screen
will allow the user to change the output of the Analog
Module. This will result in sudden jumps in output,
precaution needs to be considered if output controls the
motion of the cylinder.
 Home Screen: Will return to home page.
 Update Time: Set the Intellinder reader to maximum
update time. If reader is replaced it is recommended to
optimize update time, by pressing the F2 key.
 Section displays current setting:
 Zero/Span: Allow user to set desired zero and span
output to appropriate cylinder position.
Update Time: Time in mS that the reader produces
data.
Zero Value: Raw cylinder position value in inch units
at which the minimum output value is set. On voltage
units, it is set to “0”, on Current output units it is set to 4
mA. Note: For reverse acting outputs, this value may be
larger than Maximum.
Max Value: Raw cylinder position value in inch units
at which the maximum output value is set. On voltage
units, it is set to “10”, on Current output units it is set to
20 mA. Note: For reverse acting outputs, this value may
be lower than Minimum.
Style: Output configuration, Either Voltage or Current.
Note: Pressing the “OK” button  will refresh the setting.
 Analog Type: Allows user to change output type
Voltage or Current style.
9
www.parker.com/cylinder
Parker Hannifin Corporation
Industrial Cylinder Division
Des Plaines, Illinois USA
Intellinder™ Feedback Device
Installation Instructions for Analog Out Modules
Bulletin HY08-0880-M1
Change Analog Type Screen
MD3 Calibration Module Screen Descriptions – Change Analog Type Screen
On previous screen, pressing
the F4 key will change display
to AOM Set Up screen.
The F2 key  will toggle
the desired setting option.
When the desired setting 
is displayed, pressing the
F3 key , will prompt the
operator to confirm change.
15
14
16
17
6
User prompt to confirm that
they wish to make change.
The output type listed in the
style field  will be set in the
module.
Press confirm to make
change, cancel to return.
Note: It will take
approximately 1-2 seconds
to make change. Style
field will display module
configuration. OK button 
will refresh if necessary.
10
www.parker.com/cylinder
Parker Hannifin Corporation
Industrial Cylinder Division
Des Plaines, Illinois USA
Intellinder™ Feedback Device
Installation Instructions for Analog Out Modules
Bulletin HY08-0880-M1
Zero and Span Adjustments
MD3 Calibration Module Screen Descriptions – Zero and Span Adjustments
9
6
10
11
12
On the Intellinder Setup
screen, pressing the F3 key
 will display the Zero and
Offset setup page.
13
F3 key  from above will
display the Zero/Span AOM
Set up screen.
Pressing the F2 key  will
enter in the Zero set point
routine. This is the point in
cylinder stroke where the
output is at minimum value.
“0” V on voltage units, “4” mA
on Current units.
18
Pressing the F4 key  will
enter in the Span set point
routine. This is the point in
cylinder stroke where the
output is at max value. “10” V
on voltage units, “20” mA on
Current units.
19
11
www.parker.com/cylinder
Parker Hannifin Corporation
Industrial Cylinder Division
Des Plaines, Illinois USA
Intellinder™ Feedback Device
Installation Instructions for Analog Out Modules
Bulletin HY08-0880-M1
Zero and Span Adjustments
MD3 Calibration Module Screen Descriptions Zero and Span Adjustments
Change Zero F2 key pressed.
The user is prompted to
confirm that the cylinder is
located at correct position to
establish the Zero point.
Pressing the F4 key  will
establish the current cylinder
position as the “zero value”.
20
Change Span F4 key
pressed.
The user is prompted to
confirm that the cylinder is
located at correct position to
establish the Span (end point)
for generating the output
Max level.
Pressing the F4 key  will
establish the current cylinder
position as the “span” value.
20
12
www.parker.com/cylinder
Parker Hannifin Corporation
Industrial Cylinder Division
Des Plaines, Illinois USA
Bulletin HY08-0880-M1
Intellinder™ Feedback Device
Installation Instructions for Analog Out Modules
13
www.parker.com/cylinder
Parker Hannifin Corporation
Industrial Cylinder Division
Des Plaines, Illinois USA
07/14 / Catalog HY08-0880-M1/NA
Parker Hannifin Corporation
Industrial Cylinder Division
500 South Wolf Road
Des Plaines, IL 60016 USA
phone (847) 298-2400
fax (800) 892-1008
www.parker.com/cylinder
Parker Hannifin Corporation
Motion and Control Division
160 Chisholm Drive
Milton, ON Canada L9T 3G9
direct (905) 693-3000
fax (905) 876-1958
www.parker.com
Download PDF