Product Specifications
760103457 | Z-024
024--DN
DN--5K
5K--F12BK/D
LazrSPEED® Indoor/Outdoor Low Smoke Zero Halogen Single Jacket All-Dielectric
Arid-Core Drop Cable
Product Classification
Portfolio
CommScope®
Product Type
Fiber drop cable
Regional Availability
Asia
|
Australia/New Zealand
|
s2
|
EMEA
|
Latin America
|
North America
Standards And Qualifications
EN50575 CPR Cable EuroClass
Dca
Cable Qualification Standards
ANSI/ICEA S-110-717
|
d1
|
a1
Representative Image
General Specifications
Cable Type
Riser rated low smoke
Construction Type
Non-armored
Subunit Type
Gel-filled
Construction Materials
Fiber Type Solution
OM4, LazrSPEED® 550
Jacket Material
PE
Total Fiber Count
24
Fiber Type
OM4, LazrSPEED® 550
Fiber Type, quantity
24
Fibers per Subunit, quantity
12
©2018 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope.
All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: February 22, 2018
page 1 of 3
March 31, 2018
Product Specifications
760103457 | Z
760103457 | Z--024
024--DN
DN--5K
5K--F12BK/D
Jacket Color
Black
Jacket UV Resistance
UV stabilized
Dimensions
Buffer Tube/Subunit Diameter
4.00 mm | 0.16 in
Cable Weight
48.0 lb/kft
Diameter Over Jacket
8.30 mm | 0.33 in
Subunit, quantity
2
|
72.0 kg/km
Physical Specifications
Minimum Bend Radius, loaded
12.5 cm | 4.9 in
Minimum Bend Radius, unloaded
8.3 cm | 3.3 in
Tensile Load, long term, maximum
400 N
|
Tensile Load, short term, maximum 1334 N
Vertical Rise, maximum
90 lbf
|
572.0 m
300 lbf
|
1876.6 ft
Flame Test Specifications
Flame Test Method
IEC 60332-3
|
IEC 60754-2
|
IEC 61034-2
|
IEEE 383
|
UL 1666
|
UL 1685
Environmental Specifications
Environmental Space
Aerial, lashed
Installation Temperature
-20 °C to +60 °C (-4 °F to +140 °F)
|
Buried
|
Low Smoke Zero Halogen (LSZH)
Operating Temperature
-20 °C to +70 °C (-4 °F to +158 °F)
Storage Temperature
-20 °C to +75 °C (-4 °F to +167 °F)
|
Riser
Mechanical Test Specifications
Compression
10 N/mm | 57 lb/in
Compression Test Method
FOTP-41
Flex
35 cycles
Flex Test Method
FOTP-104
Impact
2.17 ft lb
|
2.94 N-m
Impact Test Method
FOTP-25
|
IEC 60794-1 E4
Strain
See long and short term tensile loads
Strain Test Method
FOTP-33
Twist
10 cycles
Twist Test Method
FOTP-85
Water Penentration
24 h
Water Penentration Test Method
FOTP-82
|
IEC 60794-1 E3
|
IEC 60794-1 E6
|
IEC 60794-1 E1
|
IEC 60794-1 E7
|
IEC 60794-1 F5
Environmental Test Specifications
Cable Freeze
-2 °C
Cable Freeze Test Method
FOTP-98
|
|
Drip
70 °C
158 °F
Drip Test Method
FOTP-81
|
28 °F
|
IEC 60794-1 F15
IEC 60794-1 E14
©2018 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope.
All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: February 22, 2018
page 2 of 3
March 31, 2018
Product Specifications
760103457 | Z
760103457 | Z--024
024--DN
DN--5K
5K--F12BK/D
Heat Age Test Method
IEC 60794-1 F9
Low High Bend
-20 °C to +60 °C (-4 °F to +140 °F)
Low High Bend Test Method
FOTP-37
Temperature Cycle
-20 °C to +70 °C (-4 °F to +158 °F)
Temperature Cycle Test Method
FOTP-3
|
|
IEC 60794-1 E11
IEC 60794-1 F1
Regulatory Compliance/Certifications
Agency
RoHS 2011/65/EU
ISO 9001:2008
CENELEC
Classification
Compliant
Designed, manufactured and/or distributed under this quality management system
EN 50575 compliant, Declaration of Performance (DoP) available
Included Products
CS-5K-LT (Product Component—not orderable)
— LazrSPEED® 550 OM4 Bend-Insensitive Multimode Fiber
* Footnotes
Operating Temperature Specification applicable to non-terminated bulk fiber cable
©2018 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope.
All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: February 22, 2018
page 3 of 3
March 31, 2018