BEGA
Small scale floodlight with mounting canopy
Installation and Technical Information
7806MH
Tools Required:
Dimensions
3mm hex key
5mm hex key
Flat head screw driver medium
Phillips head screw driver medium
CSA certified to U.S. and Canadian standards. Suitable
for wet locations.
A:
9”
B:
11-7/8 ”
C:
9”
D:
5-1/8 ”
Protection Class: IP65
Weight: 8.6 lbs.
Notice to Installer for 7806MH:
1. In conformance with UL Standard 1598, a silicone based sealant must be used
between luminaire and supporting surface.
2. Luminaire mounts directly to standard recessed 4” octagonal wiring (by
others), using mounting plate provided.
3. Cannot be aimed more than 45° below horizontal.
7806MH - installation:
1. Loosen the (1) 3mm hex screw on the luminaire canopy and remove
luminaire base from luminaire.
2. Feed luminaire wiring through the luminaire base and mounting plate.
3. Make supply wiring and luminaire wiring connections inside the wiring box:
MAIN VOLTAGE SUPPLY WIRE TO BLACK LUMINAIRE WIRE
NEUTRAL (COMMON) SUPPLY WIRE TO WHITE LUMINAIRE WIRE
GREEN GROUND WIRE TO GREEN LUMINAIRE WIRE
4. Attach provided mounting plate directly to a 4” standard octagonal wiring box
using the (2) screws (provided). Place a small bead of silicone around the back side of the mounting plate that will come in contact with the finished surface (exterior applications only).
5. Align and position mounting plate on mounting surface to correspond with specified mounting orientation.
6. Slip luminaire base over the mounting plate. Tighten nuts on the studs (provided) to secure.
7. Replace luminaire canopy (with luminaire attached) and tighten (1) set screw.
8. Loosen (3) faceplate trim screws and remove faceplate with lens. Insert lamp (by others). Replace faceplate trim.
9. To adjust head angle, use 5mm hex key to loosen adjustment screw. Adjust
luminaire head as needed and tighten adjustment screw.
Figure 1
Figure 2
CONCRETE
INSTALLATION
IMPORTANT: Cannot be aimed more than 45° below horizontal.
See submittal drawing.
.
HOLLOW-WALL
INSTALLATION
Relamping/Maintenance
Remove trim and lens by loosening screws. Clean
luminaire and lens using only solvent-free cleansers.
Replace lamp. Replace trim and lens. Tighten
screws.
Accessories
Please refer to the appropriate
accessory installation sheet for
further instruction when applicable.
Floodlight Shield
758
Replacement Parts
Description
Part No
Lens
Lens gasket
Lampholder
Ballast (120/208/240/277V)
140853
831281
74121
75278
Lamp: 150W T6 G 12
Philips : CDM150/T6
Osram/Sylvania : MC150T7.5/G12/U
GE : CMH150TU/G12
In the interest of product improvement, BEGA reserves the right to make technical changes without notice.
BEGA 1000 Bega Way, Carpinteria, CA 93013 (805)684-0533 Fax (805)566-9474 www.bega-us.com © Copyright BEGA-US 2012
7806MH
6/20/2012