7%
E
Metering
Modular energy (kWh) meters
Lovato
Socomec
E-1
E-7
Modular multi-meters
Lovato
Socomec
E-2
E-8
Panel mount network analysers
Lovato
Socomec
E-3 – 4
E-8 – 9
Digital panelmeters
Lovato
E-5 – 6
Digiware power montoring system
Socomec
E-10 – 12
Current transformers (CT's)
MBS
EM
E-13 – 18
E-20
Split core current transformers (CT's)
MBS
J&D
E-18
E-20
Analog panel meters
EM
E-21
Portable network analysers
Circuitor
E-22
Power analyser
Socomec
E-23
Energy meters (kWh meters)
Energy meters are digital instruments for the measurement of electrical energy consumption in single and three
phase systems with direct connection or via current transformer (CT)
Digital meters with LCD screen
typeinput
description
current
Single phase direct connection 40/63A
DMED110T1
•
•
•
•
•
Rated supply voltage:
Input current:
Active energy:
Reactive energy:
Compliant with standards:
DMED100T1
DME120T1
40A
staticmodule
pulse
width x
output
18 mm
(modular design DIN rail mountable)
220 - 240 VAC +15…-20%
40/63A (direct connection)
Class 1 (IEC/EN 62053-21)
Class 2 (IEC/EN 62053-23)
IEC/EN 61010-1, 61000-6-2, 61000-6-3
direct connection digital energy meter
1
1
Multi-measurements:
Total and partial active, reactive energy, active, reactive power,
voltage, current and power factor.
DMED110T1
DMED120T1
DMED121
DMED130
direct connection digital energy meter
direct connection digital energy meter
as above with RS485 interface
expandable with EXM1001 module
40A
63A
63A
63A
3 phase direct connection 63A/80A
Multi-measurements:
price
1
1
–
–
1
2
2
2
1183.00
2207.00
1546.00
2456.00
2137.00
(modular design DIN rail mountable)
Total and partial active, reactive energy, active, reactive power,
voltage, current and power factor.
• Graphic backlit LCD screen with 6+1 digits
• Tariff selection (2 tariffs)
DMED300T263A
3ph+N digital energy meter24
3372.00
DMED30180A 3ph+N digital energy meter (RS485)–4
4365.00
3 phase CT connection …/5A
Multi-measurements:
(modular design DIN rail mountable)
Total and partial active, reactive energy, active, reactive power,
voltage, current and power factor.
• Backlit LCD screen (128 x 80 pixels)
DMED300T2
*
DMED310T2 DMED330
/5A
/5A
3ph digital energy meter
3ph digital energy meter (RS485)
2
–
4
4
3841.00
4684.00
* Accepts EXM... (up to 3) plug-in optic expansion modules
Data concentrator
(modular design DIN rail mountable)
DMECD data concentrator designed in combination with energy meters, permitting connection to
(up to 8) devices, eliminating online communication interface requirements. The concentrator is
able to count static pulse outputs from the connected energy meters, storing data for viewing on its
display or directly on a PC through the built-in RS485 port, using Xpress software.
DMECD
•
•
•
•
•
Graphic backlit LCD screen (128 x 80 pixels)
8 inputs for pulse count, expandable up to 14 using EXM… type expansion modules
8 total and 8 partial energy meters
Built-in RS485 interface (Modbus-RTU or ASCII)
Expandable with EXM... (up to 3) plug-in optic expansion modules
DMECD data concentrator for up to 8 connected energy meters– 4 5691.00
Expansion modules for DMED310T2 and DMECD
EXM1000
E-1
(modular design DIN rail mountable)
EXM1000
2 digital inputs and 2 static outputs, opto-isolated
2
2319.00
EXM1001
2 opto-isolated digital inputs and 2 relay outputs (5A 250 VAC)
2
2319.00
EXM1010
opto-isolated USB interface
2
2319.00
EXM1011
opto-isolated RS232 interface
2
2319.00
EXM1012
opto-isolated RS485 interface
2
2319.00
EXM1013
opto-isolated Ethernet interface with Web server function
2
4593.00
EXM1020
opto-isolated RS485 interface and 2 relay outputs (5A 250 VAC)23320.00
EXM1030
data storage, clock-calendar (RTC) with backup for data logging
2
5411.00
Above prices do not include VAT. E&OE
DMG series digital multimeters / Power analysers
n
DMG digital multimeters and power analysers are equipped with a digital LCD display providing extremely clear,
intuitive and flexible viewing of all electrical parameters in an installation. DMG digital multimeters in a modular
housing (4 modules wide)
Metering
ew
• Modular DIN rail mounting (aligns with standard MCB 45mm cutout)
• Accuracy:
DMG100
Voltage/Current:
Power:
Frequency:
Active energy:
price
economical with icon display
Auxiliary power supply:
100 - 240 VAC / 120 - 250 VDC
Input current:
CT - 1A or 5A
Voltage measurement:
50 - 720 VAC L-L
Harmonic analysis of V and I up to the 15th order
DMG100
DMG110
modular power analyser
modular power analyser with RS485 interface
DMG200 series LCD multimeters
with graphic backlight LCD display
• Auxiliary power supply:
• Input current:
• Voltage measurement:
100 - 240 VAC / 110 - 250 VDC
CT - 5A
20 - 830 VAC L-L
4
4
3410.00
3956.00
DMG200
modular power analyser
4
4547.00
DMG210
modular power analyser with RS485 interface
4
5911.00
4
6820.00
DMG300 series (expandable)
•
•
•
•
•
•
•
EXM1000
module
width x 18 mm
description
DMG100 series LCD multimeters
•
•
•
•
DMG300
(True RMS measurements)
Main measurements:
- Voltage: phase, line and system values
- Current: phase values (neutral current calculated)
- Power: apparent, active and reactive phase and total values
- Power Factor (PF) per phase and total
- Frequency of measured voltage value
- HIGH-LOW-AVERAGE value functions of all measurements
- Maximum demand of power and current values
- Asymmetric voltage and current
- Total harmonic distortion (THD) of voltage and current values
- Energy meters for active, reactive and apparent values
- Hour counter (total and partial)
type
DMG200
±0.5%
±1% f.s.
±0.05%
Class 1
Auxiliary power supply:
100 - 240 VAC / 110 - 250 VDC
Input current:
CT - 1A or 5A
Voltage measurement:
20 - 830 VAC L-L /10-480 VAC L-N
Optional communication ports:
USB, RS232, RS485, Ethernet
Harmonic analysis of voltage and current up to the 31° order
Energy meters for active, reactive, apparent power with programmable tariff function
Accuracy:
voltage/current
±0.2%
power/power factor
±0.5%
frequency
±0.05%
active energy
class 0.5S (IEC/EN 62053-22)
DMG300
*
with graphic backlight LCD display
*
modular power analyser
(up to 344 measured quantities)
Accepts EXM...(up to 3) plug-in optic expansion modules
Expansion modules and accessories for DMG300
EXM1010
Above prices do not include VAT. E&OE
EXM8004
sealable terminal cover for DMG200/210/300
2
75.00
EXM1000
2 digital inputs and 2 static outputs, opto-isolated
2
2319.00
EXM1001
2 opto-isolated digital inputs and 2 relay outputs (5A 250 VAC)
2
2319.00
EXM1010
opto-isolated USB interface
2
2319.00
EXM1011
opto-isolated RS232 interface
2
2319.00
EXM1012
opto-isolated RS485 interface
2
2319.00
EXM1013
opto-isolated Ethernet interface with Web server function
2
4593.00
EXM1020
opto-isolated RS485 interface and 2 relay outputs (5A 250 VAC)
2
3320.00
EXM1030
data storage, clock-calendar (RTC) with backup for event logging
2
5411.00
E-2
DMG series digital multimeters /
Power analysers
ew
n
Flush mounting expandable digital multimeters (96 x 96 mm)
• Rear expansion slots accept plug-in modules suitable for numerous applications
• True RMS measurements of voltage and current values
Main measurements and functions :
DMG 600
-
Voltage: phase, line and system values
Current: phase values (neutral current calculated)
Power: apparent, active and reactive phase and total values
Power Factor (PF)per phase and total
Frequency of measured voltage value
HIGH-LOW-AVERAGE value functions for all measurements
Maximum demand of power and current values
Voltage and current asymmetry
Total harmonic distortion (THD): voltage and current
Energy meters with programmable tariff functions
Hour counter for programmable total and partial hours
type
DMG600 series
•
•
•
•
•
expansion
slots
description
price
economical with backlit LCD icon display
Harmonic analysis of voltage and current up to the 15° order
Auxiliary power supply:
90 - 484 VAC / 94 - 300 VDC
Input current:
CT - 1A or 5A
Voltage measurement:
50 - 720 VAC L-L
Accuracy:
Voltage/current
±0.5%
Power/power factor
±1% f.s.
Frequency
±0.05%
Active energy
Class 1 (IEC/EN 62053-21)
Reactive energy
Class 2 (IEC/EN 62053-23)
DMG600
DMG610
digital panel mount power analyser
digital panel mount power analyser (with RS485 port)
1
1
3865.00
4547.00
4
4774.00
* Expandable with EXP module (1)
DMG700 series
DMG 700
•
•
•
•
•
DMG700
*
panel mount power analyser
Expandable with EXP module (up to 4 modules)
DMG800 series
•
•
•
•
•
•
DMG 800
with backlit graphic LCD display
Graphic LCD display
Harmonic analysis of voltage and current up to the 31° order
Auxiliary power supply:
90 - 484 VAC / 94 - 300 VDC
Input current:
CT - 1A or 5A
Voltage measurement:
20 - 830 VAC L-L / 10 - 480 VAC L-N
Accuracy:
Voltage/current
±0.2%
Power/power factor
±0.5%
Frequency
±0.05%
Active energy
Class 0.5S (IEC/EN 62053-22)
Reactive energy
Class 2 (IEC/EN 62053-23)
DMG800
panel mount power analyser
4
6820.00
DMG800D048
(as above but with 9 - 70 VDC supply)
4
8184.00
*
E-3
with backlit graphic LCD display
Auxiliary power supply:
100 - 440 VAC / 94 - 300 VDC
Input current:
CT - 5A
Voltage measurement:
20 - 830 VAC L-L / 10 - 480 VAC L-N
Pulse counter for consumption of water, gas, etc., (only with expansion module)
Accuracy:
Voltage/current
±0.5%
Power
±1% f.s.
Frequency
±0.05%
Active energy
Class 1 (IEC/EN 62053-21)
Reactive energy
Class 2 (IEC/EN 62053-23)
Expandable with EXP module (up to 4 modules)
Above prices do not include VAT. E&OE
DMG series digital multimeters /
Power analysers
Flush mounting expandable digital multimeters (96 x 96 mm)
Metering
• Graphic touch-screen LCD display for extremely simple interaction
• Rear expansion slots accept plug-in modules suitable for numerous applications
• True RMS measurements of voltage and current values
Main measurements and functions :
DMG900
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Voltage: phase, phase-neutral and ground neutral-earth
Current: phase values
Neutral current calculated and true values
Power: apparent, active and reactive phase and total values
P.F. Power Factor per phase and total
Cosφ per phase
Frequency of measured voltage value
Voltage and current asymmetry
Total harmonic distortion (THD) of voltage and current
Harmonic analysis of voltage and current up to the 63° order
HIGH-LOW-AVERAGE value functions for all measurements
Maximum demand of power and current values
Energy meters with programmable tariff functions
Hour counter for programmable total and partial hours
Pulse counter for consumption of water, gas, etc., (only with expansion module)
Energy quality analysis to EN 50160 (only with expansion module)
typedescription
DMG900 series
DMG900T
Graphic touch-screen LCD display
• Auxiliary power supply:
• Input current:
• Voltage measurement:
•Accuracy:
voltage/current
power/power factor
frequency
active energy
reactive energy:
DMG900
DMG900D048
expansion
price
slots
100 - 440 VAC /110 - 250 VDC
CT - 1A or 5A
20 - 830 VAC L-L / 10 - 480 VAC L-N
±0.2%
±0.5% f.s.
±0.05%
Class 0.5S (IEC/EN 62053-22)
Class 2 (IEC/EN 62053-23)
panel mount power analyser
4
13640.00
(as above but with 9 - 70 VDC supply)4
22328.00
DMG900T
DIN rail mount measurement transducer (expandable)
DIN rail mounting measurement transducer for chassis mounting, incorporating 4 expansion
slots to accommodate expansion modules for added I/O's or communication requirements.
DMG900T
DMG900TD048
panel mount power analyser
4
16902.00
(as above but with 9 - 70 VDC supply)4
20308.00
DMG900RD
remote panel mount (96 x 96 mm) touch screen display for above DMG900T
6905.00
Expansion modules and accessories for DMG700/800/900 (up to 4 per meter)
Inputs and outputs
DMG900RD
EXP1000
EXP1001
EXP1002
EXP1003
EXP1004
EXP1005
4 digital opto-isolated inputs
1221.00
4 static opto-isolated outputs
1221.00
2 digital inputs and 2 static outputs, opto-isolated
1465.00
2 output relays (5A 250 VAC)1465.00
2 analog opto-isolated inputs
0/4 -20mA or 0-5/10V (only for DMG800/900)
4393.00
2 analog opto-isolated outputs
0/4 -20mA or 0-5/10V (only for DMG800/900) 4393.00
Communication ports
EXP1010
EXP1011
EXP1012
EXP1013
EXP1014
EXP1015
EXP1030
EXP1031
opto-isolated USB interface
opto-isolated RS232 interface
opto-isolated RS485 interface
opto-isolated Ethernet interface opto-isolated Profibus-DP interface
(only for DMG800/900)
GPRS/GSM modem without antenna
data storage, clock-calendar (RTC) with backup for data logging
as above with energy quality (EN 50160)
(only for DMG900/900T)
2197.00
2197.00
2197.00
4381.00
6820.00
5271.00
5153.00
10981.00
Software and accessories for DMG300/700/800/900
EXP1000
Above prices do not include VAT. E&OE
C2
PC - RS232 connecting cable (1.8m)
697.00
C5
RS232 analog modem cable
(1.8m)
798.00
C9 cable
PC - analog modem cable
(1.8m)
913.00
CX03
GSM Quad-band antenna for EXP1015 (850/900/1800/1900/2100MHz)
944.00
E-4
Digital meters (measuring and monitoring instruments)
DMK modular digital monitoring devices
•
•
•
•
•
Modular DIN rail mounting (3 modules ‒ 54 mm wide)
Auxiliary supply: 220 - 240 VAC
Memorises minimum and maximum measured values (since last reset)
Instantaneous or preset trip delays (0 - 900sec)
1 changeover relay output
(8A 250 VAC)
type
DMK80R1
monitored
range
description
Voltage monitors
(measures and displays single and three phase voltages)
Overvoltage range:
Undervoltage range:
Voltage/phase loss or failure:
Programmable PT ratio :
Off / 102 - 120%
(delay 0 - 900sec)
Off / 70 - 98%
(delay 0 - 900sec)
Off / 5 - 85%
(delay 0 - 900sec)
1.00 - 500.00 (accuracy: ±0.25% f.s. ±1digit)
DMK80R1
DMK70R1
1-phase over/under voltage meter/monitor
3-phase over/under voltage meter/monitor
Current monitors
(measures and displays single and three phase currents)
Measurement range:
Overcurrent range:
Undercurrent range:
Instantaneous tripping:
0.05A - 5.75A
Off / 102 - 200%
Off / 5 - 98%
Off / 110-600%
DMK81R1
DMK71R1
1-phase over/under current meter/monitor
3-phase over/under current meter/monitor
Frequency monitors
(measures and displays line frequency)
Measurement range:
0.05A - 5.75A (CT ratio: 5-10.000A) ±0.5%
DMK83R1
frequency meter/monitor
15 - 660 VAC
15 - 660 VAC
price
1588.00
1767.00
(CT ratio: 5 - 10.000A) ±0.5%
(delay 0 - 900sec)
(delay 0 - 900sec)
0.05A - 5.75A
0.05A - 5.75A
1646.00
1900.00
45 - 65Hz
2230.00
DMK81R1
Three-phase multi-measurement instrument
Measurement range:
– Voltage
DMK83R1
– Current
Phase loss or failure:
Maximum voltage:
Minimum voltage
Off / 5 - 85%
Off / 102 - 120%
Off / 70 - 98%
35 - 660 VAC
Asymmetry:
Phase sequence:
Off / 2 - 20%
Off / L1-L2-L3 / L3-L2-L1
Current loss:
Maximum current:
Off / 2 - 100%
Off / 102 - 200%
0.05 - 5.75A
Maximum current instantaneous trip: Off / 110 - 600%
– Power
Rated power:
Maximum power:
Max power instantaneous trip:
Minimum power:
1 - 10.000
Off / 101 - 200%
Off / 110 - 600%
Off / 10 - 99%
– Frequency
Maximum frequency:
Minimum frequency:
Off / 101 - 110%
Off / 90 - 99%
DMK75R1
3-phase multi measurement digital meter/monitor
45 - 65Hz
2683.00
DMK75R1
E-5
Above prices do not include VAT. E&OE
Digital panel meters (measuring and monitoring instruments)
Digital panel meters
Panel mount (H) 48 x (W) 96 mm
Auxiliary supply 220 - 240 VAC (others on request)
True RMS measurements
Class 0.5 (±0.25% full scale ± 1 digit)
Memory storage of maximum and minimum values
1 changeover relay output 8A 250 VAC 1
Flush 96 x 48 mm panel mounting
Programmable time delay for max, min or voltage/current loss (0 - 900 sec)
type
Voltmeters
(panel mounting 96 x 48 mm)
Voltage measurement range:
Operating frequency range:
Programmable VT ratio:
Accuracy:
15 - 660 VAC
45 - 65Hz
1.00 - 500.0
±0.25% f.s. ±1 digit
DMK00
DMK10
single phase digital voltmeter three phase digital voltmeter Voltmeter / monitor
DMK10R1
DMK03R1
meter only
meter only
1 changeover relay output
Settings
–Voltage loss or failure: –Maximum voltage:
–Minimum voltage:
DMK00R1
DMK10R1
single phase digital voltage monitor
three phase digital voltage monitor
102 - 120% Ue
5 - 85% Ue 70 - 98Ue 1 changeover relay output
–Current loss:
–Maximum current:
–Instantaneous trip::
–Minimum current:
DMK01R1
DMK11R1
single phase digital current monitor
three phase digital current monitor
Frequency meter
accuracy: ± 1 digit
Measurement input:
Frequency measure range:
Accuracy:
15 - 660 VAC
15 - 65Hz
±1 digit
DMK03
digital frequency meter only
meter only
meter only
0.05 - 5.75A
0.05 - 5.75A
1534.00
1677.00
relay out
relay out
0.05 - 5.75A
0.05 - 5.75A
1790.00
1932.00
meter only
15 - 65Hz
1534.00
15 - 65Hz
1790.00
multi-meter
multi-meter
2942.00
3148.00
time delay
time delay
Settings:
–Maximum frequency:
–Minimum frequency:
DMK03R1
digital frequency monitor relay output
Multi-meter Voltage measurement range:
Current measurement range:
Operating frequency range:
Programmable VT ratio:
Programmable CT ratio:
DMK16
DMK16R1
Off / 101 - 110% (0.5 - 900sec)
Off / 90 -99%
(0.5 - 900sec)
combination voltage, current, power factor
• Voltage:
phase-to-phase values
•Current: 3 phase
• Active, reactive, apparent power and energy
Above prices do not include VAT. E&OE
1790.00
1932.00
Off / 2 - 100%
(0 - 900sec)
Off / 102 - 200% (0 - 900sec)
Off / 110 - 600%
Off / 5 - 98%
(0 - 900sec)
Frequency meter / monitor 1 changeover relay output
DMK11R1
15-660 VAC
15-660 VAC
0.05 - 5.75A
45 - 65Hz
5 - 10.000
±0.5% f.s. ±1 digit
Settings
15-660 VAC1534.00
15-660 VAC1677.00
relay out
relay out
Current measurement range:
Operating frequency range:
Programmable CT ratio:
Accuracy:
Ammeter / monitor
price
(0 - 900sec)
(0 - 900sec)
(0 - 900sec)
accuracy: ± 0.5% full scale ± 1 digit
single phase digital ammeter only
three phase digital ammeter only monitored
range
time delay
Ammeters DMK01
DMK11
DMK01R1
output
description
Metering
DMK00R1
•
•
•
•
•
•
•
• Power factor
•Frequency
• Hour counter
35 - 660 VAC
0.05 - 5.75A
45 - 65Hz
1.00 - 500.0
5 - 10.000
three-phase multi-meter only
three-phase multi-meter and monitor
meter only
relay out
E-6
COUNTIS active energy meters (kwh meters)
COUNTIS Active energy meters (kwh meters)
Energy meters are digital instruments for the measurement of electrical anergy consumption in single and
three phase systems with direct connection or via a current transformer (CT)
RS485dual
width in
type
currentreading
description
price
modbus tariff
17.5 mm
Single phase direct connection kWH meters
•
•
•
•
•
4850 3019
LCD display
Measurement accuracy:
Rated supply voltage:
Pulse output:
Active energy:
(modular design DIN rail mounting)
1%
230 VAC
100Wh
Class 1 (IEC/EN 62053-21) class B (EN 50470)
4850 3019 E00
32A
direct
no
no
single phase kwh meter
1
910.00
4850 3039 E03
40A
direct
yes
yes
single phase kwh meter
1
1397.00
4850 3000 E10
63A
direct
no
no
single phase kwh meter
3
1401.00
4850 3001 E11
63A
direct
no
yes
single phase kwh meter
3
1631.00
4850 3043 E13
80A
direct
yes
yes
single phase kwh meter
3
3183.00
80A
direct
no
yes
single phase kwh meter
2
7384.00
*
4850 3047 E17
* Ethernet web server embedded
4850 3043
Three phase kWH meters ew
n
4850 3054
(modular design DIN rail mounting)
• Backlit LCD display
• Rated supply voltage:
230 - 400 VAC
• Pulse output:
100Wh
• Phase/neutral inversion protection
• Detection of connection errors
• Measurement accuracy:
1%
•Bidirectional (energy consumption and production) E27, E33, E45 only
• Active energy:
Class 1 (IEC/EN 62053-21) class B (EN 50470)
4850 3003 E20
63A
direct
no
no
three phase kwh meter
4
3179.00
4850 3004 E21
63A
direct
no
yes
three phase kwh meter
4
3574.00
4850 3050 E23
80A
direct
yes
yes
three phase kwh meter
4
3983.00
4850 3054 E27
80A
direct
no
yes
three phase kwh meter 4
8837.00
4850 3005 E30
100A
direct
no
no
three phase kwh meter
7
3806.00
4850 3006 E31
100A
direct
no
yes
three phase kwh meter
7
4113.00
4850 3012 E33
100A
direct
yes
via com
three phase kwh meter
7
4788.00
*
* Ethernet web server embedded
Note MID compliant devices available on request.
CT operated .../5A
4850 3012
4850 3008 E40
../5A
CT
no
no
three phase kwh meter
4
2665.00
4850 3017 E43
../5A
CT
yes
via com
three phase kwh meter
4
3492.00
../5A
CT
yes
via com
three phase kwh meter
4
4225.00
*
4850 3027 E45
*
Mbus
Pulse concentrator (modular design DIN rail mounting)
COUNTIS ECi2 multi-utility pulse concentrator allows for up to 7 pulse inputs from water, gas,
compressed air and electricity meters to be registered and stored. All data can be centralised
via RS485 communication using MODBUS protocol.
•
•
•
•
•
4853 0000
E-7
Load curves are available for each of the 7 logical inputs
Partial, total, daily, weekly or monthly kWh or other types of data (litres, m3…)
Customisation by selection of the measuring unit: kWh, m3, litres
Generate event alarms (1 dedicated relay output)
230 - 400 VAC supply
4853 0000 ECi2
yes
pulse concentrator for up to 7 inputs
4
4720.00
Above prices do not include VAT. E&OE
DIRIS multi-function meters (PMD)
DIRIS multi-function meters
• Compact: • Compliant: • Advanced: • RS485: • Ease of use: Metering
Compact and ergonomic, the DIRIS multifunction meter specially adapted for monitoring and managing electrical
energy. Its communication function allows the analysis of data collected via a PLC energy management software.
Panel or Din rail mount options enables easy integration into any type of electrical cabinet
IEC61557-12 high-level standard for all PMDs (Performance Monitoring Devices)
Programmable input and output as standard including pulse metering,
alarm report and pulse output
Communication permits the extraction of data and device configuration remotely.
Permits easy navigation via direct keys and easy to read backlit LCD screen display
Multi-measurement (model dependant)
w
ne
4825 0010
•
•
•
•
•
•
•
•
•
Current
Voltage and frequency
Frequency
Power
Power factor
Energy
Harmonic analysis
Events
Energy accuracy
type
-
-
-
-
-
-
-
-
-
Instantaneous and maximum average I1, I2, I3, In
Instantaneous V1, V2, V3, U12, U23, U31,F
45~65 Hz
Instantaneous and maximum average 3P, ΣP, 3Q, ΣQ, 3S, ΣS
Instantaneous 3PF, ΣPF and maximum average
Active energy: +/- kWh Reactive energy: +/- kvarh - hours
THD Current, voltage, phase-to-phase voltage
Alarms on all electrical values
Active energy class 0.55
auxiliarynumber
powerplug-in
supplymodules
DIRIS A10 multi-function meter
description
price
DIN rail mount
The DIRIS A10 is a modular multifunction meter for measuring electrical values in low voltage networks.
It allows all electrical parameters to be displayed and utilised for communication and/ or output functions.
•
•
•
•
•
•
Navigation is via 5 direct access keys and easy to read screen display
Harmonic analysis up to (level 51)
Integrated temperature sensor
Detects wiring errors to automatically correct CT installation errors
Dual tariff selection
Dimensions: 72 x 90 mm x 64 mm deep
4825 0010
4825 0011
110 - 277 VAC
110 - 277 VAC
4
4
A10
A10
72 x 90 mm DIN rail mount multifunction meter
as above with RS485 MODBUS comms
2818.00
2991.00
Available in light grey on request
DIRIS A14 multi-function meter
4825 0020
DIN rail mount
DIRIS A14 with MID certification provide the guaranteed accuracy required for applications in which
sub-billing of the electrical energy consumed is necessary. A14 Bi-directional metering (four quadrants)
function is for measuring energy production or consumption.
• Auxiliary power supply : Self supply
• Display of electrical values ( I,U,V, ΣP, ΣQ, ΣQ, ΣS, PF) and P + load curve
Over a 7 day period via communication
• Total and partial metering +/- Kwh +/- Kvarh
• Harmonic analysis (via comm) up to level 63
• Multi traffic functions (via comm.) selection of one our of four billing tariffs
•Dimensions:
72 x 90 mm x 64 mm deep
4825 0020 50 to 460 VAC +/- 15%
4
A14
DIRIS A17 multi-function meter
72 x 90 mm MID + RS485 MODBUS comm.
3956.00
panel mount
The DIRIS A17 compact meter includes a programmable input and output as standard
on all versions, functions include pulse metering, alarm report and pulse output.
• Navigation is via 4 direct access keys and easy to read screen display
• Harmonic analysis up to (level 31)
•Dimensions:
72 x 72 mm x 60 mm deep
4825 0101
Above prices do not include VAT. E&OE
4825 0101
4825 0102
220 - 277 VAC
220 - 277 VAC
–
–
A17
A17
72 x 72 mm panel mount multifunction meter
as above with RS485 MODBUS comms
2811.00
3390.00
E-8
DIRIS multi-function meters (PMD)
type
auxiliary number
powerplug-in
supplymodules
DIRIS A20 multi-function meter
description
price
panel mount
DIRIS A20 multifunction meters are panel mounted measurement units which ensure the user
has access to all the measurements required for successfully carrying out energy efficiency projects
and ensuring the electric distribution is monitored.
•
•
•
•
•
4825 0200
Detects wiring errors to automatically correct CT installation errors
Hours metering
Harmonic analysis up to (level 51)
Accepts 1 x functional plug-in module for 1 x output or RS485 MODBUS communication
Dimensions: 96 x 96 mm x 60 mm deep
4825 0200
110 - 400 VAC
1
A20
DIRIS A40/41 multi-function meter
96 x 96 mm panel mount multi-function meter
2959.00
panel mount
The Diris A40/41 series provides access to all measurements required for successfully carrying out
energy efficiency projects for electrical distribution monitoring, the units are easily customisable
or upgradeable through optional plug-in modules (up to 4).
•
•
•
•
•
•
•
•
A41 has CT current input for measuring neutral current as well
Provides accurate instantaneous, average and maximum levels of most important measurements
Metering Active, reactive and apparent energy with hours
Harmonic analysis up to (level 53)
Provide load curves of Active/Reactive power with voltages and frequency
Internal temperature and external temperature (via 3 PT100 sensors)
Accepts 4 x functional plug-in modules
Dimensions: 96 x 96 mm x 60 mm deep
4825 0201
4825 0202
110 - 400 VAC
110 - 400 VAC
4
4
A40
A41
96 x 96 mm panel mount multi-function meter
as above with neutral monitoring
5229.00
7537.00
4825 1201
4825 1202
12 - 48 VDC
12 - 48 VDC
4
4
A40
A41
96 x 96 mm panel mount multi-function meter
as above with neutral monitoring
8239.00
10841.00
4825 0201
DIRIS A60 multi-function meter energy monitoring and event analysis
The Diris A60 incorporates all functions of the A40 with additional enhanced data logging functions,
recording curves for quality events. All information can be analysed remotely using
freely downloadable analysis software from the SOCOMEC website.
•
•
•
•
Indicates current and voltage imbalances and tangent φ
Stores load curves (60 days with intervals of 10 mins) for active, reactive, apparent power
Detects and stores last 40 events - overvoltage, voltage dips, cut-offs, overcurrent
for each stored event A60 records the relevant RMS 10ms interval curves
Dimensions: 96 x 96 mm x 60 mm deep
4825 0207
110 - 400 VAC
4
A60
96 x 96 mm panel mount multi-function meter
8639.00
Accessories for DIRIS meters
Plug-modules
type
4825 0094
E-9
(for customisation or upgrading of meters)
function
description
for model
4825 0080
1 x output
plug-in optional modules
A20
335.00
4825 0082
RS485 MODBUS comms
plug-in optional modules
A20
481.00
4825 0090
2 configurable pulse outputs
plug-in optional modules
A40/41/A60
481.00
4825 0092
RS485 MODBUS comms
plug-in optional modules
A40/41/A60
682.00
4825 0093
2 Analog outputs
plug-in optional modules
A40/41/A60
1349.00
4825 0094
2 inputs / 2 outputs
plug-in optional modules
A40/41/A60
755.00
4825 0205
Sub D9 PROFIBUS DP comm
plug-in optional modules
A40/41
4459.00
4825 0097
Memory
plug-in optional modules
A40/41
682.00
4825 0203
Ethernet communication
with Embedded Webserver functionA40/41/A602728.00
4825 0204
Ethernet + RS485 MODBUS
with Embedded Webserver functionA40/41/A603183.00
4825 0089
IP65 protection
IP65 protection cover for DIRIS meters
A40/41/A60
255.00
Above prices do not include VAT. E&OE
Introducing Digiware
(measurement and monitoring for electrical installations)
The DIRIS Digiware is a multi-circuit power monitoring device that is the most effective solution for metering consumption. Measuring and monitoring the
quality of electrical energy in industrial and commercial applications.
Can monitor several circuits via a single current measurement module thanks to independent current inputs
Implementation in a quarter of the time vs existing metering technologies
Accuracy as per standard IEC 61557-12 (Class 0.5)
Installation of measurement modules and current sensors at the closest point to the load
Compact and flexible design: suitable for new and existing installations including panels with space restrictions
Metering
•
•
•
•
•
Build a system:
Voltage
measurement
module
Display/
No display module
Multiple current
measurement
modules
Current sensors
The solution for
•Industry
•Building
•Infrastructure
•Local authority
Advantages
•Multi-circuit
•Global accuracy class 0.5
•Cost effective and flexible
•Plug & play
module
typedescription
price
width
w
ne
Control and power supply interface
• Power supply 24 VDC (required see page B-56)
• Communication via RS485 Modbus and Digiware BUS
C-31 data Interface system
• No-display mode
• Centralises all of the systems' data on MODBUS RS485
4829 0101
4829 0101
•
•
•
•
18 mm modular centralisation unit
D-40/50 centralisation and display of data
1809.00
panel mount 96 x 96 mm
High-resolution LCD display
Local view of data from the voltage and current modules
Keys on the front face for direct access to, measurement data,circuit selection,device configuration
Power supply 24 VDC (required see page B-56)
D-40
4829 0199
centralisation unit with multi-point display and RS485 output
4650.00
centralisation unit with multi-point display and Ethernet communication (Modbus TCP)
5125.00
D-50
4829 0201
C-32 range extending repeater
4829 0201
• Required when Digiware bus length exceeds 100m
• Maximum bus length 300m (2 repeaters)
• Power supply 24 VDC (required see page B-56)
4829 0103
range extending repeater
Note: For RJ45 connecting cables for above see E-12
18 mm
2171.00
E-10
Digiware power monitoring
/ energy management
Voltage measurement modules
w
ne
1 single voltage measurement point for the entire system.
• A complete,dedicated solution for : metering,voltage monitoring,quality analysis of the voltage
• RJ45 bus allows you measurement of voltage as well as supply power to all connected devices
• 3 phase voltage and frequency monitoring
module
typedescription
price
width
U-10 metering module
4829 0105
modular voltage measurement metering module
18 mm
2026.00
18 mm
2713.00
18 mm
3083.00
U-20 monitoring module (as above but with additional 3ph THDu monitoring)
4829 0106
4829 0106
modular voltage measurement monitoring module (harmonics)
U-30 analysis module (all electrical parameters including history of average values)
4829 0102
modular voltage measurement analysis module
Current measurement modules
Allocates the load to be measured or to monitor independent current inputs i.e three-phase load
and 3 single-phase loads.
•
•
•
•
•
A complete,dedicated solution for : metering,voltage monitoring,quality analysis of the voltage
RJ45 and RJ12 rapid connection and automatically configures connected current sensors
Wiring errors are also prevented and implementation is simplified
Metering: ± kWh, ± kvarh, kVAh
Multi-measurement: I1, I2, I3, In, ΣP, ΣQ, ΣS, ΣPF
currentmodule
typedescription
inputs width
4829 0112
I-30/60 metering modules
4829 0110
4829 0112
I-30 modular current measurement metering module
I-60 modular current measurement metering module
3
6
18 mm
36 mm
2171.00
3627.00
3
6
18 mm
36 mm
3024.00
5065.00
I-31/61 metering and load curve modules
4829 0111
4829 0113
I-31 modular current measurement metering module
I-61 modular current measurement metering module
I-35/45 analysis module (all electrical parameters including history of average values)
4829 0130
4829 0131
TE...
I-35 modular current measurement analysis module
I-45 modular current measurement analysis module
3
4
18 mm
27 mm
4174.00
7959.00
Current sensors
Various types of current sensors can be connected to the Solid TE,split-core TR,TF current sensors.
These sensors automatically recognizes the sensor size and type and can be adapted to all types
of new and existing installations.
TE 90
• Plug and play RJ12 connections (for ease of wiring preventing wiring errors)
• Automatic detection of sensor type and current rating
nominal
type
model
description
current (A)
pitch
(mm)
hole size
(mm)
solid current sensor
solid current sensor
solid current sensor
solid current sensor
solid current sensor
solid current sensor
solid current sensor
18
18
25
35
45
55
90
Ø 8.6
Ø 8.6
13.5 21 31 41 64 ■
■
■
■
■
377.00
387.00
435.00
484.00
677.00
869.00
1584.00
split-core current sensors
split-core current sensors
split-core current sensors
split-core current sensors
–
–
–
–
Ø 10
Ø 16
Ø 24
Ø 36
1174.00
1401.00
1785.00
2027.00
–
–
–
Ø 55
Ø 120
Ø 800
3952.00
4434.00
4916.00
TE - solid current sensors
• Suitable for new installations - match the pitch of protective devices
4829 0500
4829 0501
4829 0502
4829 0503
4829 0504
4829 0505
4829 0506
TR...
TE-18
TE-18
TE-25
TE-35
TE-45
TE-55
TE-90
5…20
25…63
40…160
63…250
160…630
400…1000
600…2000
TR - split-core current sensors
TF...
4829 0551TR-10 25…75
4829 0552TR-16 32…100
4829 0553TR-24 63…200
4829 0554TR-36200…600
TF - flexible current sensors (Rogowski coil)
4829 0570TF-55 150…600
4829 0571TF-120
400…2000
4829 0572TF-300
600…16000
E-11
flexible current sensors
flexible current sensors
flexible current sensors
Above prices do not include VAT. E&OE
Digiware power monitoring
/ energy management
description
cablepack
price
lengthsize
Cables and accessories for current sensor
Metering
w
ne
type
model
RJ12 current sensor connection
• Automatic detection of ratings
• Identification of cables by colour-coding
• Disconnection of the current sensor secondary under load
RJ12
4829 0581
4829 0595
4829 0583
4829 0584
4829 0593
4829 0594
4829 0601 *
RJ12 RJ12 RJ12 RJ12 RJ12 RJ12 RJ12 current sensor connection cable
current sensor connection cable
current sensor connection cable
current sensor connection cable
current sensor connection cable
current sensor connection cable
current sensor cable + 50 connectors
0.2 m
0.5 m
1.0 m
2.0 m
1.0 m
2.0 m
50 m
(3x cables)
(3x cables)
(3x cables)
(3x cables) (6x cables) (6x cables) (cable roll)
158.00
189.00
237.00
349.00
478.00
697.00
3284.00
RJ45 current sensor connection
RJ45
• Interconnection of I and U modules via Digiware bus
• Auto-configuration of parameters: Network and load type - addressing of devices connected to the bus
4829 0181
4829 0182
4829 0183
4829 0184
4829 0185 RJ45
Digiware bus connection cable
RJ45
Digiware bus connection cable
RJ45
Digiware bus connection cable
RJ45
Digiware bus connection cable
RJ45 current sensor cable + 50 connectors
4829 0599
4829 0598
4829 0600
5A/CT adapter (measurement >1000 A)
677.00
coupling link for interconnecting sensors staggered or linear mounted (30pcs)
422.00
sealable cover (guarantees the immunity of sensor connection)
(20pcs)
422.00
0.1 m
0.5 m
1.0 m
2.0 m
50 m
(cable roll)
*
* Maximum cable distance between current measurement modules and current sensors is 10 m
4829 0302
Communication gateways
59.00
84.00
111.00
171.00
5343.00
wireless and cabled RS485 to Ethernet
DIRIS G communication gateways communicate all information from metering and measurement
devices wirelessly or via RS485 bus, centralised in a single device and made available on the
Ethernet network via Modbus TCP. The gateway has an embedded WEBVIEW web server,
permitting real time monitoring of electrical values and analysis of consumption data.
• Plug and Play automatic detection and addressing of measurement and metering devices
• Automatic recording and storage of measurements and consumption data, sending of alarms
• Ethernet/RS485 Modbus communication with embedded WEBVIEW power monitoring
module
typedescription
width
Consumption history (Webview)
DIRIS G-50
4829 0302
DIRIS G-60
4829 0303
power and energy monitoring communication gateway
62 mm
12206.00
wireless (radio frequency) and cabled RS485 to Ethernet
power and energy monitoring communication gateway
62 mm
14099.00
Power monitoring device (stand alone unit)
The DIRIS B-30 is a PMD in modular format that communicates wirelessly or via RS485.
The 4 RJ independent current inputs allows it to manage several types and number of circuits
i.e 4 single-phase loads or 1 three phase load + 1 single-phase load (compatible G-50 /60).
B-30 RS
Above prices do not include VAT. E&OE
4829 0000
B-30 RS RS485 MODBUS communication 54 mm
5886.00
4829 0002
B-30 RF Radio Frequency communication (wireless)
54 mm
6857.00
4829 0200
D-30 single point display for B-50
96 x 96 mm
2713.00
4829 0280
RJ9 cable for above D-30 display unit
1.5m
89.00
4829 0281
RJ9 cable for above D-30 display unit
3.0m
131.00
panel mount
E-12
Current transformers
Made in Germany
General specifications
•
•
•
•
•
Nominal frequency:
Isolation class:
Nominal thermal short-time current:
Maximum operating voltage:
Over-current limiting factor:
50Hz (others on request)
E
Ith = 60 x In
Um ≤ 0.72 kV
FS 5 up to 1500 A nominal current
MBS AG current transformers conform fully to: DIN VDE 0414/1 - DIN 42600 - IEC 61869/1+2 - VBG 4
type
ASR 20.3
ratio
description Tube/ring type current transformers
ASR 20.3
50/5A
tube current transformer
1
1
65
45
30
264.00
26029
60/5A
tube current transformer
1
1.25
65
45
30
264.00
26031
75/5A
tube current transformer
1
1.5
65
45
30
264.00
26035
100/5A
tube current transformer
1
2.5
65
45
30
264.00
26041
150/5A
tube current transformer
1
3.75
65
45
30
264.00
26051
200/5A
tube current transformer
1
3.75
65
45
30
264.00
26046
250/5A
tube current transformer
1
5
65
45
30
264.00
55013
DIN rail adaptor for above current transformers
5A secondary - class 1
current transformers
30 x 10 / 20 x 20 mm
7038
50/5A
std current transformer
1
1
76
61
48
264.00
7039
60/5A
std current transformer
1
1
76
61
48
264.00
7041
75/5A
std current transformer
1
1.5
76
61
48
264.00
7045
100/5A
std current transformer
1
2.5
76
61
48
264.00
7047
150/5A
std current transformer
1
2.5
76
61
48
264.00
7050
200/5A
std current transformer
1
5
76
61
48
264.00
7053
250/5A
std current transformer
1
10
76
61
48
264.00
55011
DIN rail adaptor for above current transformers
Ø round conductor: 26 mm
73.00
current transformers
Primary bar conductor: 40 x 10 / 30 x 10 mm
13044
100/5A
std current transformer
1
2.5
86
71
58
223.00
13048
150/5A
std current transformer
1
5
86
71
58
223.00
13050
200/5A
std current transformer
1
5
86
71
58
223.00
13054
250/5A
std current transformer
1
10
86
71
58
223.00
13057
300/5A
std current transformer
1
10
86
71
58
223.00
13062
400/5A
std current transformer
1
15
86
71
58
223.00
13066
500/5A
std current transformer
1
15
86
71
58
223.00
13070
600/5A
std current transformer
1
15
86
71
58
223.00
13073
750/5A
std current transformer
1
15
86
71
58
223.00
13077
800/5A
std current transformer
1
30
86
71
58
223.00
55012
DIN rail adaptor for above current transformers
ASK 51.4
E-13
73.00
Primary bar conductor: ASK 41.4 ASK 51.4
Ø round conductor: 21 mm
26027
ASK 31.3 ASK 41.4
dimensions (mm)
price
(H) (W)(D)
VA
5A secondary - class 1
tube current transformers Busbar mounted current transformers
ASK 31.3
class
Ø round conductor: 32 mm
73.00
current transformers
Primary bar conductor: 50 x 10 / 40 x 20 mm
16055
400/5A
std current transformer
1
10
99
86
58
282.00
16060
500/5A
std current transformer
1
15
99
86
58
282.00
16064
600/5A
std current transformer
1
15
99
86
58
282.00
16068
750/5A
std current transformer
1
15
99
86
58
282.00
16071
800/5A
std current transformer
1
15
99
86
58
282.00
16075
1000/5A
std current transformer
1
15
99
86
58
282.00
Ø round conductor: 44 mm
Above prices do not include VAT. E&OE
Current transformers
Made in Germany
ASK 61.4 ratio
description class
VA
dimensions (mm)
price
(H) (W)(D)
current transformers
Primary bar conductor: 60 x 10 / 50 x 20 mm
19065
19069
19073
19076
19085
std current transformer
std current transformer
std current transformer
std current transformer
std current transformer
600/5A
750/5A
800/5A
1000/5A
1250/5A
Ø round conductor: 44 mm
1
1
1
1
1
15
15
15
30
30
96
96
96
96
96
58
58
58
58
58
287.00
287.00
287.00
287.00
287.00
120
120
120
120
120
120
58
58
58
58
58
58
469.00
469.00
469.00
469.00
469.00
469.00
40
40
40
532.00
532.00
532.00
52
52
52
52
578.00
578.00
578.00
578.00
99
99
99
99
99
99
40
40
40
40
40
40
1343.00
1382.00
1421.00
1464.00
1503.00
1556.00
100
100
100
100
40
40
40
40
1655.00
1846.00
1928.00
1928.00
106
106
106
106
106
ASK 61.4
Standard current transformers ASK 81.4 current transformers
Primary bar conductor: 80 x 10 / 60 x 30 mm
21045
21049
21053
21056
21064
21072
std current transformer
std current transformer
std current transformer
std current transformer
std current transformer
std current transformer
ASK 101.4
ASK 103.41
5A secondary - class 1
600/5A
750/5A
800/5A
1000/5A
1250/5A
1600/5A
1
1
1
1
1
1
10
15
15
15
15
30
124
124
124
124
124
124
current transformers
Primary bar conductor: 100 x 10 / 80 x 30 mm
22055
22062
22070
std current transformer
std current transformer
std current transformer
ASK 103.3
Ø round conductor: 55 mm
1250/5A
1600/5A
2000/5A
Ø round conductor: 70 mm
1
1
1
30
30
30
144
144
144
130
130
130
current transformers
Primary bar conductor: 100 x 30 / 80 x 50 mm
23058
23062
23066
23070
std current transformer
std current transformer
std current transformer
std current transformer
1600/5A
2000/5A
2500/5A
3000/5A
Rectangular shaped current transformers
Ø round conductor: 85 mm
1
1
1
1
30
30
30
30
188
188
188
188
172
172
172
172
5A secondary - class 1
ASK 103.41 current transformers
ASK 41.4
Primary bar conductor: 103 x 41 mm
97054
97056
97058
97060
97062
97066
std current transformer
std current transformer
std current transformer
std current transformer
std current transformer
std current transformer
500/5A
600/5A
750/5A
800/5A
1000/5A
1250/5A
Ø round conductor: 40 mm
1
1
1
1
1
1
5
5
5
10
15
15
150
150
150
150
150
150
ASK 128.4 current transformers
Primary bar conductor: 128 x 38 mm
94056
94058
94060
94062
std current transformer
std current transformer
std current transformer
std current transformer
1250/5A
1500/5A
2000/5A
2500/5A
Ø round conductor: 38 mm
1
1
1
1
15
30
30
30
178
178
178
178
ASK 103.3
Above prices do not include VAT. E&OE
E-14
Metering
type
Current transformers
Made in Germany
type
ratio
description Class 0.5 current transformers 5A secondary
ASK 41.4 ASK 41.4
40 x 10 / 30 x 10mm
13085
13086
13087
13088
13089
13090
std current transformer
std current transformer
std current transformer
std current transformer
std current transformer
std current transformer
ASK 103.3
50 x 10 / 40 x 20mm
std current transformer
std current transformer
std current transformer
std current transformer
600/5A
750/5A
800/5A
1000/5A
60 x 10 / 50 x 20mm
19031
19034
19040
std current transformer
std current transformer
std current transformer
800/5A
1000/5A
1250/5A
80 x 10 / 60 x 30mm
21023
21029
21035
std current transformer
std current transformer
std current transformer
1000/5A
1250/5A
1600/5A
100 x 30 / 80 x 50mm
23026
23029
23032
23035
std current transformer
std current transformer
std current transformer
std current transformer
1600/5A
2000/5A
2500/5A
3000/5A
Primary wound current transformers
WSK 40
31070
31074
5/5A
10/5A
15/5A
20/5A
E-15
40
40
40
40
40
40
492.00
492.00
492.00
492.00
492.00
492.00
86
86
86
86
58
58
58
58
605.00
605.00
605.00
605.00
96
96
96
58
58
58
669.00
669.00
669.00
120
120
120
58
58
58
905.00
905.00
905.00
Ø round conductor: 44 mm
0.5
0.5
0.5
0.5
15
15
15
15
99
99
99
99
Ø round conductor: 44 mm
0.5
0.5
0.5
15
15
15
106
106
106
Ø round conductor: 55 mm
0.5
0.5
0.5
15
15
15
124
124
124
Ø round conductor: 85 mm
0.5
0.5
0.5
0.5
15
30
30
30
188
188
188
188
172
172
172
172
35
35
35
35
1433.00
1433.00
1433.00
1433.00
5A secondary - class 1
wound current transformer
wound current transformer
wound current transformer
wound current transformer
1
1
1
1
5
5
5
5
79
79
79
79
61
61
61
61
35
35
35
35
737.00
737.00
737.00
737.00
1
1
10
10
89
89
71
71
45
45
860.00
860.00
primary wound current transformers
25/5A
30/5A
wound current transformer
wound current transformer
KSU 2/3 summation current transformers
41015
41031
5+5/5A
5+5+5/5A
SUSK 4
summation current transformers
40027
71
71
71
71
71
71
86
86
86
86
86
86
primary wound current transformers
Summation current transformers SUSK 4
5
5
10
10
15
15
current transformers
Primary bar conductor: 30022
30024
30026
30028
0.5
0.5
0.5
0.5
0.5
0.5
current transformers
Primary bar conductor: WSK 30 Ø round conductor: 32 mm
current transformers
Primary bar conductor: ASK 81.4
(class 0.2 available on request)
current transformers
16154
16203
16033
16036
ASK 103.3
WSK 40
200/5A
250/5A
300/5A
400/5A
500/5A
600/5A
Primary bar conductor: ASK 61.4
dimensions (mm)
price
(H) (W)(D)
VA
current transformers
Primary bar conductor: ASK 51.4 class
5+5+5+5/5A
5A secondary - class 1
wound current transformer
wound current transformer
wound current transformer
1
1
10
10
94
94
127
127
57
57
1210.00
1914.00
1
10
137
156
65
2394.00
Above prices do not include VAT. E&OE
Current transformers
Made in Germany
ratio
description Class 1 ASK 41.4
ASK 41.4
Above prices do not include VAT. E&OE
dimensions (mm)
price
(H) (W)(D)
1A secondary current transformers
current transformers
40 x 10 / 30 x 10 mm
13239
13244
13248
13250
13254
13257
13262
13266
13270
75/1A
100/1A
150/1A
200/1A
250/1A
300/1A
400/1A
500/1A
600/1A
std current transformer
std current transformer
std current transformer
std current transformer
std current trans former
std current transformer
std current transformer
std current transformer
std current transformer
55012
DIN rail adaptor for above current transformers73.00
Ø round conductor: 32 mm
1
1
1
1
1
1
1
1
1
2.5
2.5
5
5
10
10
15
15
15
86
86
86
86
86
86
86
86
86
71
71
71
71
71
71
71
71
71
40
40
40
40
40
40
40
40
40
346.00
346.00
346.00
346.00
346.00
346.00
346.00
346.00
346.00
current transformers
Primary bar conductor:
50 x 10 / 40 x 20 mm
16260
16264
16268
16271
16275
std current transformer
std current transformer
std current transformer
std current transformer
std current transformer
ASK 61.4 ASK 103.3
VA
Primary bar conductor: ASK 51.4
ASK 61.4
class
500/1A
600/1A
750/1A
800/1A
1000/1A
Ø round conductor: 44 mm
1
1
1
1
1
15
15
15
15
15
86
86
86
86
86
58
58
58
58
58
282.00
282.00
282.00
282.00
282.00
96
96
96
96
96
58
58
58
58
58
287.00
287.00
287.00
346.00
287.00
120
120
120
120
40
40
40
40
795.00
795.00
795.00
795.00
35
35
35
35
35
673.00
673.00
673.00
673.00
673.00
99
99
99
99
99
current transformers
Primary bar conductor: 60 x 10 / 50 x 20 mm
19265
19269
19273
19277
19285
std current transformer
std current transformer
std current transformer
std current transformer
std current transformer
600/1A
750/1A
800/1A
1000/1A
1250/1A
Ø round conductor: 44 mm
1
1
1
1
1
15
15
15
30
30
106
106
106
106
106
ASK 81.4 current transformers
current transformers
Primary bar conductor:
80 x 10 / 60 x 30 mm
Ø round conductor: 55 mm
21253
21256
21264
21272
std current transformer
std current transformer
std current transformer
std current transformer
800/1A
1000/1A
1250/1A
1600/1A
1
1
1
1
15
15
15
30
124
124
124
124
ASK 103.3 plug-in current transformers
current transformers
Primary bar conductor: 100 x 30 / 80 x 50 mm
Ø round conductor: 85 mm
23251
23258
23262
23266
23270
std current transformer
std current transformer
std current transformer
std current transformer
std current transformer
1250/1A
1600/1A
2000/1A
2500/1A
3000/1A
1
1
1
1
1
30
30
30
30
30
188
188
188
188
188
172
172
172
172
172
E-16
Metering
type
Current transformers
Made in Germany
The CTB range with "cage clamp ®" termination (uneffected by vibration and shock) offers a higher
maximum operating voltage (Um < 1,2 kV) and increased isolation test voltage (6 kV Ueff, 1 min., 50 Hz) as
well as increased ambient temperature range (-5 °C < T < +50 °C).
General specifications
cage clamp ®
•
•
•
•
•
•
•
Nominal thermal current Icth: 1.2 x In (continuous)
Therm. nominal short-time current Ith:
60 x In, 1 sec.
Maximum operating voltage Um: 1.2 kV
Isolation test voltage: 6 kV, Ueff, 50 Hz, 1 min.
Nominal rated frequency: 50 Hz
Isolation class: E
UL-zertifiziert - Certificate Number - 20100426-E336996, DIN EN 61869 part 1+2
Ø round
typeratio
conductor
description class
VA
dimensions (mm)
price
(H)(W)(D)
Current transformers with screwless connection technology
CTB 31.35 current transformers Primary bar conductor: 50-0002
50-0004
50-0005
50-0006
50-0008
50-0010
50-0012
50-0014
CTB 31.35
100/5A
150/5A
200/5A
250/5A
300/5A
400/5A
500/5A
600/5A
5A secondary class 1
30 x 10 / 25 x 12 / 20 X 20 mm
25.7 mm
25.7 mm
25.7 mm
25.7 mm
25.7 mm
25.7 mm
25.7 mm
25.7 mm
std current transformer
std current transformer
std current transformer
std current transformer
std current transformer
std current transformer
std current transformer
std current transformer
CTB 41.35 current transformers Primary bar conductor: 50-0058
50-0060
50-0062
50-0064
50-0066
50-0068
CTB 41.35
400/5A
500/5A
600/5A
750/5A
800/5A
1000/5A
50-0113
50-0115
50-0117
50-0119
750/5A
800/5A
1000/5A
1250/5A
std current transformer
std current transformer
std current transformer
std current transformer
std current transformer
std current transformer
800/5A
1000/5A
1250/5A
1600/5A
std current transformer
std current transformer
std current transformer
std current transformer
50-0198
50-0200
50-0204
50-0206
1000/5A
1250/5A
1600/5A
2000/5A
std current transformer
std current transformer
std current transformer
std current transformer
CTB 101.35
E-17
1250/5A
1600/5A
2000/5A
2500/5A
91
91
91
91
91
91
70
70
70
70
70
70
52
52
52
52
52
52
337.00
337.00
337.00
337.00
337.00
337.00
1
1
1
1
10
10
10
10
105
105
105
105
85
85
85
85
52
52
52
52
387.00
387.00
387.00
387.00
1
1
1
1
10
10
10
10
115
115
115
115
95
95
95
95
52
52
52
52
455.00
455.00
455.00
455.00
135
135
135
135
120
120
120
120
52
52
52
52
578.00
578.00
578.00
578.00
147
147
147
147
130
130
130
130
52
52
52
52
746.00
746.00
746.00
746.00
CTB 31+41
all CTs
73.00
46.00
5A secondary class 1
std current transformer
std current transformer
std current transformer
std current transformer
CTB 101.35 current transformers 50-0240
50-0244
50-0246
50-0248
5
10
10
10
10
10
80 x 10 / 60 x 30 mm
54.7 mm
54.7 mm
54.7 mm
54.7 mm
Primary bar conductor: 1
1
1
1
1
1
63 x 10 / 50 x 30 mm
43.7 mm
43.7 mm
43.7 mm
43.7 mm
Primary bar conductor: 287.00
287.00
287.00
287.00
287.00
287.00
287.00
287.00
5A secondary class 1
CTB 81.35 current transformers CTB 81.35
52
52
52
52
52
52
52
52
5A secondary class 1
CTB 61.35 current transformers 50-0159
50-0161
50-0163
50-0167
60
60
60
60
60
60
60
60
50 x 10 / 40 x 30 mm
43.7 mm
43.7 mm
43.7 mm
43.7 mm
Primary bar conductor: 81
81
81
81
81
81
81
81
5A secondary class 1
CTB 51.35 current transformers CTB 61.35
2.5
5
5
5
10
10
10
10
40 x 10 / 30 x 15 mm
31.8 mm
31.8 mm
31.8 mm
31.8 mm
31.8 mm
31.8 mm
Primary bar conductor: 1
1
1
1
1
1
1
1
1
1
1
1
10
10
10
10
5A secondary class 1
100 x 10 / 80 x 30 mm
70 mm
70 mm
70 mm
70 mm
std current transformer
std current transformer
std current transformer
std current transformer
1
1
1
1
10
15
15
15
Accessories for above CTB current transformers
55015
55021
DIN rail mounting adaptor for current transformers
quick fix quick action busbar fastening support clip
Above prices do not include VAT. E&OE
Splitcore current transformer
The split measuring system facilitates a simple installation into existing panel boards without additional
mounting requirements. Simply open the locking mechanism of the current transformer place around
the primary conductor and lock ensuring that the circuit is closed. Once the secondary conductors are
connected, the unit is ready for operation.
General specifications
•
•
•
•
•
Nominal frequency:
Isolation class:
Nominal thermal short-time current:
Maximum operating voltage:
Over-current limiting factor:
50Hz (others on request)
E
Ith = 60 x In
Um ≤ 0.72 kV
FS 5 up to 1500 A nominal current
MBS AG current transformers conform fully to: DIN VDE 0414/1 - DIN 42600 - DIN EN 60044/1 - VBG 4
round
typeratio
conductor
KBU 23 split core current transformers KBU 23
• Dimensions:
• Primary bar conductor:
• Round conductor: 80048
80030 80031 80044
100/5A
150/5A
200/5A
250/5A
KBU 58
80061
80062
80063
80064
80065
80067
80068
250/5A
300/5A
400/5A
500/5A
600/5A
800/5A
1000/5A
split core split core split core split core 80098
80100
1000/5A
1250/5A
split core split core split core split core split core split core
split-core
KBU 816
Above prices do not include VAT. E&OE
80147
80149
80151
80153
80155 80157
1600/5A
2000/5A
2500/5A
3000/5A
4000/5A
5000/5A
split-core current transformer
split-core current transformer
split-core current transformer
split-core current transformer
3
3
3
1
1.251363.00
1.51363.00
1.51363.00
1.51363.00
1
1
1
1
1
1
1
1.5
1586.00
2.51586.00
2.51586.00
5
1586.00
5
1586.00
7.5
1586.00
101586.00
1
1
101880.00
151880.00
1
1
1
1
1
1
152216.00
152216.00
152216.00
302216.00
302216.00
302216.00
5A secondary - class 1
split-core current transformer
split-core current transformer
split-core current transformer
split-core current transformer
split-core current transformer
split-core current transformer
split-core curren t transformer
5A secondary - class 1
(H) 198 x (W) 155 x (D) 58 mm
80 x 12 mm max.
split core
split core
KBU 816 split core current transformers • Dimensions:
• Primary bar conductor:
5A secondary - class 1/3
(H) 158 x (W) 125 x (D) 58 mm
50 x 80 mm max.
KBU 812 split core current transformers • Dimensions:
• Primary bar conductor:
classVA price
(H) 106 x (W) 93 x (D) 58 mm
20 x 30 mm max.
Split core
KBU 58 split core current transformers • Dimensions:
• Primary bar conductor:
description
split-core current transformer
split-core current transformer
5A secondary - class 1
(H) 243 x (W) 195 x (D) 79 mm
80 x 160 mm max.
split core split core split core split core split core split core split-core current transformer
split-core current transformer
split-core current transformer
split-core current transformer
split-core current transformer
split-core current transformer
E-18
Metering
Made in Germany
Split-core current transformers
JS series split-core current transformers 5A or 1A secondary from sensed primary current for metering
applications. They can be used for power meters, distribution systems, control panels, switchgear and
other equipment. Designed to install to live power lines without disconnection of the power source.
Built-in over voltage protection provides a safe, fast and cost-effective installation.
•
•
•
•
Light weight, compact dimensions
Simple installation
Built-in over-voltage protection
Incorporated cable tie support for securing to cable
Accuracy :
Output terminals :
Overload withstand :
Compliant with :
Operating temperature :
Test voltage :
type
ratio
class 0.5/1.0/3.0
2 x M3 screw terminals with terminal cover
720V (0.72 kV)
IEC/EN60044-1 & IEC61010-1
-24°C to 55°C
3kV for 1 minute
round
conductor
Miniature split-core current transformers
JS17S
class
VA
price
5A secondary
JS24S
JS24S-100/5A
JS24S-150/5A
JS24S-200/5A
JS24S-250/5A
JS24S-300/5A
JS24S-400/5A
100/5A
150/5A
200/5A
250/5A
300/5A
400/5A
dimensions: (H) 74.5 x (W) 45 x (D) 33.7 mm
Ø 24 mm
mini split-core current transformer
Ø 24 mm
mini split-core current transformer
Ø 24 mm
mini split-core current transformer
Ø 24 mm
mini split-core current transformer
Ø 24 mm
mini split-core current transformer
Ø 24 mm
mini split-core current transformer
3
3
1
1
1
1
1.5
1.5
0.5
0.5
0.5
0.5
861.00
861.00
861.00
861.00
861.00
861.00
JS36S
JS36S-400/5A
JS36S-500/5A
JS36S-600/5A
400/5A
500/5A
600/5A
dimensions: (H) 91.4 x (W) 57.1 x (D) 40.2 mm
Ø 36 mm
mini split-core current transformer
Ø 36 mm
mini split-core current transformer
Ø 36 mm
mini split-core current transformer
1
1
1
2.5
2.5
5.0
1133.00
1133.00
1133.00
Miniature split-core current transformers
JS24S
description
1A secondary
JS17S
JS17S-60/1A
JS17S-75/1A
60/1A
75/1A
dimensions: (H) 64 x (W) 33 x (D) 35.8 mm
Ø 17 mm
mini split-core current transformer
Ø 17 mm
mini split-core current transformer
3
3
0.2
0.5
820.00
820.00
JS24S
JS24S-100/1A
JS24S-125/1A
JS24S-150/1A
JS24S-200/1A
JS24S-250/1A
JS24S-300/1A
100/1A
125/1A
150/1A
200/1A
250/1A
300/1A
dimensions: (H) 75 x (W) 45 x (D) 34 mm
Ø 24 mm
mini split-core current transformer
Ø 24 mm
mini split-core current transformer
Ø 24 mm
mini split-core current transformer
Ø 24 mm
mini split-core current transformer
Ø 24 mm
mini split-core current transformer
Ø 24 mm
mini split-core current transformer
3
3
3
1
1
1
1.0
1.0
1.0
0.5
1.0
1.5
820.00
820.00
820.00
820.00
820.00
820.00
JS36S
JS36S-400/1A
JS36S-500/1A
JS36S-600/1A
400/1A
500/1A
600/1A
dimensions: (H) 91 x (W) 57 x (D) 40.2 mm
Ø 36 mm
mini split-core current transformer
Ø 36 mm
mini split-core current transformer
Ø 36 mm
mini split-core current transformer
0.5
0.5
0.5
0.5
0.5
0.5
1072.00
1072.00
1072.00
RMS series - output current transducers (4-20mA)
RMS Series Split-core Current Transducers are designed for energy management with a convenient
connection to electronic submeters, current measurement in distributed power line carriers (PLCs)
or remote controls such as SCADA software for automation and supervision.
•
•
•
•
•
•
JS36S
E-19
Max. permissable current :
Output :
Accuracy / linearity :
Output terminals :
Sensor supply voltage :
Operatingcondition:
120% (continuous), 150% (1 min.)
4-20mA (average)/0-ratedcurrent(loadresistance:≤600ΩatP/S:24V)
±2% FS. Dynamic range 1:100 at 50/60Hz sinewave
2 x M3 screw terminals with terminal cover
24 VDC loop power
-20°Cto50°C≤85%RH(anydirectioninstallable)
JC16F
JC16F-5-RMS
JC16F-10-RMS
JC16F-25-RMS
JC16F-50-RMS
JC16F-100-RMS
0-5A
10A
25A
50A
100A
dimensions: (H) 55 x (W) 29.5 x (D) 31 mm
Ø 16 mm
4-20mA
split-core current transducer
Ø 16 mm
4-20mA
split-core current transducer
Ø 16 mm
4-20mA
split-core current transducer
Ø 16 mm
4-20mA
split-core current transducer
Ø 16 mm
4-20mA
split-core current transducer
1761.00
1761.00
1761.00
1761.00
1761.00
JC24S
JC24S-250-RMS
250A
dimensions: (H) 75 x (W) 45 x (D) 34 mm
Ø 24 mm
4-20mA
split-core current transducer
2680.00
JC36S
JC36S-500-RMS
500A
dimensions: (H) 91 x (W) 57 x (D) 40.2 mm
Ø 36 mm
4-20mA
split-core current transducer
3292.00
Above prices do not include VAT. E&OE
Current transformers / DC shunts
ratio
description IMN1 ring type transformers
IMN1/05
IMN1/06
IMN1/07
IMN1/10
IMN1/12
IMN1/15
IMN1/16
IMN1/20
IMN1/25
IMN1...
50/5A
60/5A
75/5A
100/5A
125/5A
150/5A
160/5A
200/5A
250/5A
class
VA
dimensions (mm)
price
(H) (W)(D)
Ø round conductor: 32 mm
ring current transformer
ring current transformer
ring current transformer
ring current transformer
ring current transformer
ring current transformer
ring current transformer
ring current transformer
ring current transformer
3
3
3
1
1
1
1
1
1
1.3
1.3
1.3
2.5
2.5
3.8
3.8
5
7.5
87 6442
87 6442
87 6442
87 6442
87 6442
87 6442
87 6442
87 6442
87 6442
128.00
128.00
130.00
130.00
130.00
131.00
131.00
135.00
138.00
IMN2 current transformers
Primary bar conductor: 40 x 12.5 mm
IMN2/16
IMN2/20
IMN2/25
IMN2/30
IMN2/40
IMN2/50
IMN2/60
IRB1...
160/5A
200/5A
250/5A
300/5A
400/5A
500/5A
600/5A
Ø round conductor: 38 mm
ring current transformer
ring current transformer
ring current transformer
ring current transformer
ring current transformer
ring current transformer
ring current transformer
1
1
1
1
1
1
1
10
10
10
15
25
30
30
99 7542 99 7542 99 7542 99 7542
99 7542
99 7542
99 7542
159.00
159.00
159.00
162.00
168.00
174.00
181.00
IBR1 current transformers
Primary bar conductor: 60 x 20 mm
IBR1/06
IBR1/08
IBR1/10
IBR1/12
600/5A
800/5A
1000/5A
1250/5A
Ø round conductor: 60 mm
ring current transformer
ring current transformer
ring current transformer
ring current transformer
0.5
0.5
0.5
0.5
7.5
15
30
30
11510445
11510445
11510445
11510445
253.00
266.00
280.00
297.00
IBR3 current transformers
Primary bar conductor: 100 x 30 mm
IRB3...
IBR3/12
IBR3/16
IBR3/20
IBR3/25
IBR3/30
1250/5A
1600/5A
2000/5A
2500/5A
3000/5A
Ø round conductor: 110 mm
ring current transformer
ring current transformer
ring current transformer
ring current transformer
ring current transformer
0.5
0.5
0.5
0.5
0.5
15
30
30
30
30
17015245
17015245
17015245
17015245
17015245
367.00
382.00
417.00
446.00
475.00
0.5
0.5
0.5
0.5
0.5
0.5
0.5
5
5
5
5
5
5
5
1116843
1116843
1116843
1116843
1116843
1116843
1116843
244.00
244.00
244.00
244.00
244.00
254.00
358.00
IBNP primary wound current transformers
IBNP/05
IBNP/10
IBNP/15
IBNP/20
IBNP/25
IBNP/30
IBNP/40
5/5A
10/5A
15/5A
20/5A
25/5A
30/5A
40/5A
primary wound CT
primary wound CT
primary wound CT
primary wound CT
primary wound CT
primary wound CT
primary wound CT
DC shunts
‒Accuracy:
‒ Overload:
ACN10-5
ACN30-5
B
C
D
E
A
ACN60-5
Above prices do not include VAT. E&OE
50mV output
0.5%
120% continuously, 1000% for 5 seconds
dimensions (mm)
A B CD
ACN01-5 10A
50mV 105 25 3514.3
ACN02-5 20A
50mV 105 25 3514.3
ACN03-5 30A
50mV 105 25 3514.3
ACN04-5 40A
50mV 105 25 3514.3
ACN05-5 50A 50mV 10525 3519
ACN06-5 60A 50mV 10525 3519
ACN08-5 80A 50mV 10525 3519
ACN10-5 100A 50mV 10525 3519
ACN15-5 150A 50mV 10525 3519
ACN20-5 200A
50mV 105 25 3524.5
ACN25-5 250A
50mV 135 40 5050.8
ACN30-5
300A
50mV
135
40
50
50.8
ACN40-5 400A 50mV 13550 5038
ACN50-5 500A 50mV 13550 5038
ACN60-5 600A 50mV 13565 5038
ACN75-5 750A 50mV 13565 5038
ACN80-5
800A
50mV
135
75
50
38
ACN100-51000A
50mV
135 105 50 38
Intermediate and larger sizes up to 10.000A available on request
E
5.5
5.5
5.5
5.5
9.5
9.5
9.5
9.5
14.3
16
12.7
12.7 31.5
31.5
31.5
31.5
31.5 31.5
376.00
376.00
376.00
376.00
421.00
421.00
421.00
421.00
485.00
549.00
888.00
888.00
1192.00
1501.00
1501.00
1938.00
1938.00
2373.00
E-20
Metering
type
Analog panel instruments
typerange
description
price
48mm²72mm² 96mm
Ammeters (AC) moving iron (overscale 2 x In) (90º movement)
BEA01A
BEA05A
BEA10A
BEA15A
BEA25A
BEA40A
BEA40A
*
*
*
*
*
*
*
*
BEA01AT BEA05AT
1A
5A
10A
15A
25A
40A
direct reading AC ammeter
direct reading AC ammeter
direct reading AC ammeter
direct reading AC ammeter
direct reading AC ammeter
direct reading AC ammeter
230.00203.00 230.00
204.00178.00 204.00
204.00178.00 204.00
204.00178.00 204.00
204.00178.00204.00
204.00178.00 204.00
1A
5A
CT operated AC ammeter
CT operated AC ammeter 230.00203.00 230.00
211.00190.00 218.00
Voltmeters (AC) moving iron BEV25A
BEV40A
BEV50A
BEV60A
250V
400V
500V
600V
direct reading AC voltmeter
direct reading AC voltmeter
direct reading AC voltmeter
direct reading AC voltmeter
Frequency meters BEV40A
*
*
*
BEF50AP BEF50AR BEF50AR 3
45 - 55Hz
47 - 53Hz
47 - 53Hz
*
*
/1A
/5A
302.00198.00 222.00
302.00198.00 222.00
302.00198.00 222.00
302.00198.00 222.00
(90º movement)
frequency (pointer type) 110 - 380V
frequency (vibrating reed) 110 - 230V frequency (vibrating reed) 380 - 500V
Maximum demand ammeters ERB01A ERB05A (90° movement)
– 642.00694.00
– 642.00694.00
– 642.00694.00
(90° movement) delay time: 15 min (standard)
maximum demand ammeters
maximum demand ammeters
– 770.00816.00
–
714.00762.00
Combination maximum demand ammeters
*
*
ERBC01A ERBC05A BEF50AP
/1A
/5A
com. Max. demand ammeters
com. Max. demand ammeters
Power factor indicator *
BEP05A /5A
BEA05D
BEA10D
BEA15D
BEA20D
BEA25D
BEA30D
BEF50AR
*
*
*
*
*
*
(90° movement) 230 - 380V
power factor indicator (0.5 - 1 - 0.5)
Ammeters (DC) moving coil – 1044.001104.00
– 934.00989.00
–
1002.001002.00
(90° movement)
direct reading DC ammeter
direct reading DC ammeter
direct reading DC ammeter
direct reading DC ammeter
direct reading DC ammeter
direct reading DC ammeter
306.00355.00 372.00
306.00355.00 372.00
306.00355.00 372.00
306.00355.00 372.00
306.00355.00 372.00
306.00355.00 372.00
*
shunt operated ammeter
314.00367.00 386.00
*
*
DC (low current) ammeter
DC (low current) ammeter
346.00396.00 410.00
346.00396.00 410.00
5A
10A
15A
20A
25A
30A
BEV50MVD ❖ 50mV
BEA01MAD 1mA
BEA20MAD 4 - 20mA
❖ For DC shunts please refer to page E-20
Voltmeter (DC)
*
*
*
BEV03D BEV15D BEV60D BEMC01A
0 - 30V
1 - 150V
150 - 600V
(90° movement)
DC voltmeter
DC voltmeter
DC voltmeter
306.00355.00 372.00
306.00355.00 372.00
306.00355.00 372.00
Extra charges and accessories
144 mm² housing (90° movement) ‒ add to 96 mm² price
coloured bezels R / W / B for instruments
IP65 housing front protection
spare glass
283.00
20.00
288.00
54.00
Running hour meters
*
*
BEHCA BEHCD BEHCD
AC
DC
running hour meter 24/110/230/380 VAC
running hour meter 10 - 80 VDC
222.00541.00 582.00
403.00667.00 732.00
* 4 = 48 x 48 mm / 7 = 72 x 72 mm / 9 = 96 x 96 mm BEHCA4
E-21
Above prices do not include VAT. E&OE
A portable high-performance recorder designed for energy audits. The compact design and ease of operation is
ideal for analysis of networks with power quality supply. Most portable recorders follow highly complex parameter
configuration and start-up processes the CIRe+ has been designed to simplifying the setup and execution of
measurements and, as a consequence, the analysis of energy and audit studies.
M85050
Canvas carrying bag
•
•
•
•
•
•
•
•
•
•
•
Measures main and three-phase electrical networks in 2 quadrants
Measure (TRMS) true root mean square
Energy meter (4 quadrants)
4 voltage and 3 current circuits
Configurable via a PC application - Compatible with PowerVision software EN 50160
Recording of parameters and quality events on SD card (up to 2 GB)
Compact size, allowing the unit to be installed in standard double insulation boxes
Light and easy to transport
Self-detection of current clamps
Magnetic attachment to facilitate fastening to an electric panel or metal supports
128 samples per gate (used to calculate data over selected recording period)
CIRe+ 3 phase economy portable network analyser
type
description
Voltage :
Operating temperature:
Standard:
Accuracy :
100 - 400 VAC, 70 - 315 VAC
10ºC - 65ºC
IEC 60664-1, IEC61010-1, IEC62053-21, UL94, VDE 110
Voltage : 0.5%
M85050
Analyzer supplied complete with:
– CP E-Flex 20/54 cm current transformers 200/2000/20000 Amp
– Voltage leads
– SD memory card and USB/SD card reader (1GB)
– PC software
– Canvas carrying bag
price
52690.00
is a remote control and supervision software for LOVATO Electric devices equipped with
communication capabilities via serial ports, Ethernet or modem in a simple and reliable way. The supported
protocols are Modbus-RTU, Modbus-ASCII and Modbus-TCP. Its structure and applications are based on
MS SQL Express that uses a MS IIS Express web server to control the user interface.
The software is capable of:
• Managing multiple communication channels simultaneously
• Connecting the devices to the various channels
• Collecting data from all the devices and storing them in a database
• Displaying collected data in graphical pages and tables
• Allowing access to the devices and their data according to the rights of the different users
type
description
price
SYN1SET
supervision and energy management software (parameterising, measurement,
monitoring, control, web server, e-mail and FTP file transfer) + enablement
of monitoring on 1 LOVATO Electric device.
26517.00
SYN1S005
enable licence of supervision function for 5 additional devices.
10312.00
SYN1S020
enable licence of supervision function for 20 additional devices
30936.00
SYN1S050
enable licence of supervision function for 50 additional devices
61999.00
SYN1S100
enable licence of supervision function for 100 additional devices
105192.00
Note: For the number of licences, only devices equipped with communication ports can be considered.
Above prices do not include VAT. E&OE
E-22
Metering
Portable network analyser /
Supervision and energy management
Power analyser
DIRIS Q800 is a high-end power quality analyser, able to monitor and record the major power quality
parameters. Operating as an event/fault recorder, capable to store a high number of voltage events and
disturbances, frequency variations, inrush current, etc. Additional PQ data can be recorded, such as Flicker,
Unbalance, Harmonics and Inter harmonics, Mains Signalling. It also provides standard power measurement
data for three-phase systems. Extra voltage and current measurement channels give the possibility to
monitor Neutral Potential and Earth Leakage current.
Main benefits:
•
•
•
•
•
•
•
•
•
•
Embedded Web Server
Large colour touch screen with user-friendly instrument web interface
Fast simultaneous sampling on 9 channels at 1024 samples / cycle
Voltage event recording (sags,swells,interruptions) with storage of 1/2 cycle RMS values and waveforms
Frequency variation monitoring and recording with of 1/2 cycle RMS values and waveforms
Overcurrent recording on three-phase channels with storage of 1/2 cycle RMS values and waveforms
Continuous monitoring of the power quality and Class A certified measurements for voltage characteristics
Simultaneous recording of events, Min/Avg/Max LOG and energy counters
Analyser software is provided to perform analysis on recorded data according to EN50160 PQ standard
Export standard file formats (PQDIF and CSV) to allow quick view and analysis on all stored data
Specifications:
Power supply:
Backup Battery: Recording Memory:
85...285 VAC, 50/60 Hz / 65...250 VDC
Li-Ion,2500 mAh (>15 min autonomy)
4 GB (16 GB Optional)
Measurement inputs:
- Direct voltage measurement input:
- U4 Direct voltage measurement input:
w
ne
DIRIS Q800
P-N: max 580 V RMS CAT III,
L-L: max 1000 V RMS CAT III
Max 580 V RMS CAT III
Accuracy:
- Three-phase voltage:
- U4 voltage:
- Currents:
- Powers:
- Frequency:
- Harmonics:
- Realtime clock (RTC):
- Active energy:
- Reactive energy:
±0.1% Un over 10 ... 150% Un range
±0.2% measurement
±0.2% measurement (device)
±0.2% measurement
±8 mHz
Class 1 (IEC/EN 61000-4-7)
<1s in 24h without synchronisation;
<5ms with GPS synchronisation
Class 0.5S, compliant to IEC/EN 62053-22
Class 1, compliant to IEC/EN 62053-23
Communication:
- Ethernet ports:
- RS485 port (slave):
- WIFI antenna:
- GPS antenna:
- Protocols:
- USB port:
2 x Auto MDIX RJ45 10/100 Base Ethernet
1 x Optoisolated, 0.5UL, 2400...115200bps
1 x Passive antenna, SMA connector on rear panel
Active patch antenna, remote powered, SMA connector
HTTP, HTTPS, FTP, SFTP, NTP, NMEA,
Modbus TCP, Modbus RTU
1 x USB 2.0 A type socket, high speed 480 Mbit/s
Standard:
- Product compliance:
- Certification:
operating
type
temperature
IEC/EN 62586-1, IEC/EN 62586-2
Class A, IEC/EN 61000-4-30:2015 Ed.3 for voltage
DI
DO AI
memory description
price
DIRIS Q800 multifunction network quality analyser
4826 0100
E-23
-25 ... +55°C
4
4
4
4 GB (16 GB optional)
network quality analyser 120000.00
Above prices do not include VAT. E&OE
Notes
Download PDF
Similar pages