advertisement
Planning Information
Integrated Model 700 BF (I )
Freezer Drawers
Model 700BF
Seamless molding
Location of serial number
Magnetic drawer gaskets
Model 700BFI with Ice Maker
Front venting with removable kickplate
These appliances are Star-K certified from the factory to meet strict religious regulations in conjunction with specific instructions found on star-k.org. No extra wiring harness is required.
Electronic digital control panel
Upper freezer storage drawer
Automatic ice maker
(Model 700BFI)
Lower freezer storage drawer
The Sub-Zero Model 700BF and
700BFI integrated design accepts custom wood or stainless steel drawer panels.
Stainless steel panels and handles are available as sales accessories in three finishes—classic, platinum and carbon.
C
onsider using this two drawer unit in conjunction with a Model 601R, all refrigerator. Many customers do not have the need for lots of freezer storage in their home. With the emphasis on fresh food, customers need more refrigerator space. Now you can satisfy this need with the combination outlined above.
There is one temperature for the entire unit and the range you have is from -5˚F (-20˚C) to +5˚F (-15˚C).
Also keep in mind that this unit can be ordered with and without an ice maker.
Dimensions in parentheses are in millimeters unless otherwise specified.
11/06
1
Planning Information
Integrated Model 700 BF (I )
F E A T U R E S
Drawer unit with freezer storage drawers
Model 700BFI has automatic ice maker
Integrated design for "point-of-use" refrigeration anywhere in the home
Refrigeration system ensures the best food storage and energy efficiency
Microprocessor offers precise temperature control
Electronic digital controls are easily accessed in the top storage drawer
Flat to the ceiling bright lighting in storage drawers
Alarm will let you know with an audible beeping if a drawer is left open
Top drawer has a removable divider
Meets strict Department of Energy requirements
UL approved for US and Canada
Two, five and twelve year residential warranty – exclusions apply; warranty information can be found on our website, subzero.com
O V E R A L L D I M E N S I O N S
3
/
8
"
(10)
27"
(686)
(UNIT DIMENSION)
24"
(610)
(UNIT DIMENSION)
1
/
2
"
(13)
13
1
/
4
"
(337)
DRAWER
MOUNTING DETAIL
10
1
/
4
"
(260)
20
3
/
8
"
(518)
34
1
/
2
"*
(876)
FRONT VIEW
*
1
/
2
"
(13) +
9
3
/
4
"
(248)
4"
(102)
SIDE VIEW
24"
(610)
DRAWER CLOSED
19
1
/
2
"*
(495)
25
7
/
8
"
(657)
TOP VIEW
* DRAWER PANEL THICKNESS NOT INCLUDED
Dimensions may vary by ±
1
/
8
" (3).
Dimensions in parentheses are in millimeters unless otherwise specified.
2
Planning Information
Integrated Model 700 BF (I )
M O D E L O P T I O N S
Drawer Freezer Unit
Drawer Freezer Unit with Automatic Ice Maker
700BF
700BFI
P A N E L O P T I O N S
Integrated (custom panels)
Classic Stainless Steel Finish
Platinum Stainless Steel Finish
Carbon Stainless Steel Finish
/S
/P
/B
Stainless steel drawer front panels are ordered and shipped as sales accessories and include tubular handles.
A C C E S S O R I E S
Drawer front panels with tubular handles in classic, platinum and carbon stainless steel
Tubular handles in classic, platinum and carbon stainless steel and polished chrome
Dual installation heater kit
Accessories are available through your
Sub-Zero dealer. To obtain local dealer information, visit the Locator section of our website, subzero.com.
S P E C I F I C A T I O N S
Model 700BF(I)
Overall Width
Overall Height
Overall Depth
Freezer Capacity
Drawer Freezer Unit
27" (686)
34
1
/
2
" (876)
24" (610)
5.1 cu ft (144 L)
Minimum Height (levelers in)
Drawer Clearance
34" (864)
19
1
/
2
" (495)
Electrical Requirements 115 V AC, 60 Hz, 15 amp circuit
Plumbing Requirements
1
/
4
" copper line
Water Supply
Annual Energy Usage
(based on 9.06 cents per kilowatt hour)
Shipping Weight
Special Note
20–100 psi
488 kWh / $ 45
190 lbs (86 kg)
Drawer panels and handles are available in three stainless steel finishes
Specifications are subject to change without notice.
Dimensions in parentheses are in millimeters unless otherwise specified.
3
Planning Information
Integrated Model 700 BF (I )
I N S T A L L A T I O N S P E C I F I C A T I O N S
1
1
/
2
"
(38)
25"
(635)
*PLACEMENT OF THE
ANTI-TIP BRACKET
SHOULD BE 24" (610)
FROM THE FRONT OF THE
UNIT WITHOUT PANELS
TO THE BACK OF THE
ANTI-TIP BRACKET.
ANTI-TIP
BRACKET*
13
1
/
2
"
(343)
15
1
/
2
"
(394)
TOP VIEW TOP VIEW
9"
(229)
WATER LINE
BOTTOM ENTRY
LOCATION
27"
(686)
6"
(152)
27"
(686)
1
1
/
2
"
(38)
25"
(635)
ANTI-TIP
BRACKET
13
1
/
2
"
(343)
WATER LINE
SIDE ENTRY
LOCATIONS
27"
(686)
1
1
/
2
"
(38)
34
1
/
2
"
(876)
NOTE: ANTI-TIP BRACKET MUST BE INSTALLED TO
PREVENT UNIT FROM TIPPING FORWARD
FRONT VIEW
ANTI-TIP
BRACKET
SIDE VIEW
WATER LINE
SIDE ENTRY
LOCATION
4
1
/
2
"
(114)
LOCATE ELECTRICAL WITHIN
SHADED AREA – ORIENT GROUND
PRONG TO RIGHT AS SHOWN
ANTI-TIP
BRACKET
LOCATE WATER LINE
(REAR ENTRY) WITHIN
SHADED AREA
3"
(76)
1
/
4
"
(6)
13"
(330)
2
1
/
2
"
(64)
15
1
/
2
"
(394)
9"
(229)
3
/
4
"
(19)
D I M E N S I O N S
Finished Rough Opening Width
Finished Rough Opening Height
Finished Rough Opening Depth
Location of Electrical
Location of Plumbing
27" (686)
34
1
/
2
" (876)
25" (635)*
Within shaded area
Within shaded area
* The depth of the Model 700BF(I) is 24" (610) from the front of the unit to its back.
Your design may necessitate moving the unit back, or cabinets forward to achieve a flush fit.
This will require a minimum rough opening depth of 25" (635).
See Installation Instructions shipped with unit for detailed specifications.
Dimensions in parentheses are in millimeters unless otherwise specified.
4
Planning Information
Integrated Model 700 BF (I )
I N S T A L L A T I O N N O T E S
Refer to the illustrations and specifications for overall dimensions, finished rough opening dimensions and installation specifics.
IMPORTANT NOTE: The depth of Model 700BF(I) is 24" (610) from the front of the unit to its back. Your design may necessitate moving the unit back, or cabinets forward to achieve a flush fit. This will require a minimum rough opening depth of 25" (635). Refer to the installation illustration on page 4.
The anti-tip bracket must be installed to prevent the unit from tipping forward.
Integrated units are compatible with virtually any style of cabinetry. They can be used with framed as well as frameless cabinets.
The weight of each drawer panel cannot exceed 12 lbs (5 kg). Drawer panels must be a minimum of
5
/
8
" (16) thick.
For the bottom drawer, the maximum panel height is 16
11
/
16
" (424). You must keep a minimum space of 4" (102) clear below the bottom edge of the lower drawer panel, so the unit can be properly vented. In addition, any decorative base molding must be removable for possible servicing and cleaning of the condenser.
We recommend using D-style handles, which should be located on the top, center area of the drawer panel.
Two Integrated units may be installed next to one another. Refer to page 10 for additional information.
For Integrated models with an automatic ice maker, rough in the water supply line. Connect a
1
/
4
" OD copper line to the house supply, being sure to use an easily accessible shut-off valve between the supply and the unit. This shut-off valve should not be installed behind the unit.
Do not use self-piercing valves. A saddle valve kit (4200880) is available from your
Sub-Zero dealer. To obtain local dealer information, visit the Locator section of our website, subzero.com.
A line filter is required when water conditions have a high sediment content. The ice maker operates on water pressure of 20 psi
(1.4 bar) to 100 psi (6.9 bar). In some cases a reverse osmosis water filter system may not be able to maintain the minimum water pressure consistently.
When routing the water through the side walls, you must place the water line within
1
/
2
"
(13) of the floor and as close as possible to the back wall. The line must be routed around the anti-tip bracket so it clears the bracket and leveling feet of the unit. Refer to the installation illustration on page 4 for placement of the water line.
Do not route water supply line in front of the compressor tray. The tray must be slid forward for service.
Regardless of the routing, allow for 27"
(686) of excess copper tubing to remain outside the wall or floor for easy connection to the unit, as shown in the installation illustration.
A 115 volt, 6OHz, 15 amp circuit breaker and electrical supply are required. A separate circuit, servicing only this appliance is necessary.
All Integrated models are equipped with a power supply cord with a 3-prong grounding plug, which must be plugged into a mating
3-prong grounding type wall receptacle. The electrical outlet must be placed so the grounding prong is to the right of the thinner blades.
The outlet must be flush with the back wall.
Locate electrical within the shaded area shown in the installation illustration on page 4.
Do not use an extension cord or two prong adapter. Electrical ground is required on this appliance. Do not under any circumstances remove the power supply cord ground prong.
You must follow all National Electrical Code regulations. In addition, be aware of local codes and ordinances when installing your service.
The Integrated Refrigeration Installation
Instructions packed with the appliance will give you step-by-step procedures for making sure the unit is installed properly.
Dimensions in parentheses are in millimeters unless otherwise specified.
5
Planning Information
Integrated Model 700 BF (I )
C A B I N E T R Y A P P L I C A T I O N S
Integrated refrigeration is compatible with virtually any style and look of cabinetry. The models can be used with framed as well as frameless cabinets. Because of the precise application and the look you may want to achieve, there are important questions you need to answer before ordering panels for the drawers. As you look at styles of cabinets, keep some important facts in mind:
IMPORTANT NOTE: The depth of each Integrated unit is
24" (610) from the front of the unit to its back. You must allow for the thickness of the panel you are applying when planning for the finished rough opening depth if you want the front panel to be flush with surrounding cabinetry. You may have to move the unit back into drywall or bring the cabinets forward to achieve a flush fit.
Weight Limitations – The weight of each drawer panel cannot exceed 12 lbs (5 kg).
Panel Thickness – Drawer panels must be a minimum of
5
/
8
" (16) thick.
The toe kick clearance can vary with the height of the lower drawer panel; the maximum panel height is 16
11
/
16
"
(424). You must keep a minimum space of 4" (102) clear below the bottom edge of the lower drawer panel so the unit can be properly vented.
IMPORTANT NOTE: The inside edges of the rough opening, as well as the sides and a portion of the backside of the decorative panels will need to be finished, as they will be exposed when the drawers are open.
We recommend using D-style handles. Locate handles in the top center area of the drawer panels.
Dimensions in parentheses are in millimeters unless otherwise specified.
6
Planning Information
Integrated Model 700 BF (I )
F R A M E D C A B I N E T R Y
CABINET
FRAME
SUB-ZERO
UNIT
24
(610)
TO WALL
CABINET
DOOR
1
/
8
" (3)
REVEAL
PANEL
27
(686)
1
Traditional Frame – full overlay (top view).
2
CABINET
FRAME
SUB-ZERO
UNIT
T
24
(610)
TO WALL
CABINET
DOOR
1
1
/
8
" (3)
REVEAL
PANEL
27
(686)
(top view).
S
SUB-ZERO
UNIT
T
24
(610)
TO WALL
CABINET
FRAME
1
CABINET
DOOR
1
/
8
" (3)
REVEAL
2
PANEL
27
(686)
Traditional Frame –
3
/
8
" (10) offset
(top view).
F R A M E D C A B I N E T R Y A P P L I C A T I O N S
Framed cabinetry applications present you with different questions to address. The illustrations on this page show common applications of framed cabinetry. These are not meant to be the only alternatives, but are suggestions from designers around the country.
IMPORTANT NOTE: The depth of each Integrated unit is
24" (610) from the front of the unit to its back. You must allow for the thickness of the panel you are applying when planning for the finished rough opening depth if you want the front panel to be flush with surrounding cabinetry. You may have to move the unit back into drywall or bring the cabinets forward to achieve a flush fit. Refer to the illustrations.
Illustrations on the following pages give dimensions for an
Integrated drawer unit installed within a framed cabinetry beaded inset application. Review the illustrations, giving particular attention to the overall panel specifications.
Dimensions in parentheses are in millimeters unless otherwise specified.
7
Planning Information
Integrated Model 700 BF (I )
F R A M E D C A B I N E T R Y – B E A D E D I N S E T A P P L I C A T I O N
CABINET DOOR
SUB-ZERO
UNIT
24"
(610)
TO WALL
The illustration shows an Integrated drawer unit installed within a framed cabinetry beaded inset application.
IMPORTANT NOTE: Dimensions are based on a
1
/
8
" (3) reveal. A reveal of up to
1
/
4
" (6) is possible, but panel dimensions need to be adjusted accordingly.
TOP VIEW
A A
PANEL
27"
(686)
A) ALL REVEALS ARE 1/8" (3)
B) DRAWER RAILS ARE ATTACHED TO DRAWER FRONTS
C) BOTTOM RAIL MUST BE REMOVABLE
*DIMENSIONS MAY VARY
SHADED AREA
INDICATES STATIONARY
STYLES AND RAILS
26
3
/
4
"
(679)
PANEL WIDTH
Installation of an Integrated drawer unit within framed cabinetry.
*Dimensions may vary.
Dimensions in parentheses are in millimeters unless otherwise specified.
1
1
/
2
"
(38)
27"
(686)
FRONT VIEW
1
1
/
2
"
(38)
B
13
9
/
16
"
(345)
A
B
A
1
1
/
2
"
15
1
/
16
"
(383)
(38)
C
A
4"*
(102)
34 1 /
2
"
(876)
*
4"
(102)
24"
(610)
SIDE VIEW
8
Planning Information
Integrated Model 700 BF (I )
F R A M E L E S S C A B I N E T R Y A P P L I C A T I O N S
The illustration below shows a hypothetical installation of an Integrated drawer unit within frameless cabinetry.
Review the illustration, giving particular attention to the overall panel specifications.
IMPORTANT NOTE: Dimensions are based on a
1
/
8
" (3) reveal. A reveal of up to
1
/
4
" (6) is possible, but panel dimensions need to be adjusted accordingly.
F R A M E L E S S C A B I N E T R Y
26
3
/
4
"*
(679)
PANEL WIDTH
A
13
9
/
16
"
(345)
A
16
11
/
16
"*
(424)
4"*
(102)
TOE KICK
27"
(686)
FINISHED OPENING
A) ALL REVEALS ARE
1
/ 8 " (3)
34
1
/
2
"
(876)
*
24"
(610)
SIDE VIEW
*DIMENSIONS MAY VARY
Installation of an Integrated drawer unit within frameless cabinetry.
*Dimensions may vary.
Dimensions in parentheses are in millimeters unless otherwise specified.
9
Planning Information
Integrated Model 700 BF (I )
25
(635)
CABINETS
27
(686)
TOP VIEW
C
CABINETS
25
(635)
2
27
(686)
MINIMUM
5
/
8
" (16) SIDE PANELS
Installation with side panels.
CABINETS
25
(635)
T
54
(1372)
TOP VIEW
Installation of two units side by side.
C
CABINETS
2
M
27
(686)
MINIMUM
5
/
8
" (16) SIDE PANELS
25
(635)
Installation at end of run.
Dimensions in parentheses are in millimeters unless otherwise specified.
I N S T A L L A T I O N O P T I O N S
The illustrations on this page show some typical installations and their dimension considerations.
The depth dimension in the illustrations may vary depending on cabinet styles, treatment of countertops or other design options.
IMPORTANT NOTE: The depth of each Integrated unit is 24" (610) from the front of the unit to its back. Your design may necessitate moving the unit back, or cabinets forward to achieve a flush fit. This will require a minimum rough opening depth of 25"
(635). Refer to the illustrations.
D U A L I N S T A L L A T I O N S
If two or more Integrated models are installed side by side where there is 2" (51) or less of space between the units, a heater kit is recommended—
BBDUAL for two drawer units installed side by side or a drawer unit and a tall unit installed side by side. This optional component is available through your Sub-Zero dealer. To obtain local dealer information, visit the Locator section of our website, subzero.com.
10
Planning Information
Integrated Model 700 BF (I )
T O E K I C K C L E A R A N C E
The toe kick clearance can vary with the height of the lower drawer panel; the maximum panel height is 16
11
/
16
"
(424).
IMPORTANT NOTE: You must keep a minimum space of
4" (102) clear below the bottom edge of the lower drawer panel so the unit can be properly vented. In addition, any decorative base molding must be removable for possible servicing and cleaning of the condenser.
The illustration below shows the area below the lower drawer where the operating mechanical equipment of the
Integrated unit is housed.
IMPORTANT NOTE: The depth of each Integrated unit is
24" (610) from the front of the unit to its back. Your design may necessitate moving the unit back, or cabinets forward to achieve a flush fit. This will require a minimum rough opening depth of 25" (635). Refer to the illustration.
T O E K I C K A R E A D E T A I L
10
9
16
(268)
PANEL
10
(254)
OPTIONAL
(424)
PANEL
4
(102)
1
2
(13)
9
11
16
(246)
2
5
8
(67)
TO
4
(102)
BASE MOLDING MUST
BE REMOVABLE
25
(635)
TO WALL
FLOOR
Dimensions in parentheses are in millimeters unless otherwise specified.
11
advertisement
Related manuals
advertisement