Menu display function

LASER WITH DMX/ILDA
Ref.: SCAN500RGB/SCAN1100RGB/SCAN2000RGB/SCAN1100PINK
USER MANUAL
MODE D’EMPLOI
Imported from China by
LOTRONIC SA – Avenue Zénobe Gramme 9 – 1480 Saintes - Belgium
©Copyright Lotronic 2017
1
GB
LASER FOR PROFESSIONAL USE ONLY
This laser complies with the international standards EN60825-1:2014. It is
meant exclusively for professional use.
Its installation and use should only be carried out by a skilled technician
who is aware of the specific dangers of lasers.
REMINDER OF SAFETY INSTRUCTIONS
Lasers of class 3 and 4 are for outdoor use only.
Inside the public area, any laser shooting towards the audience is strictly forbidden except if a safety area of 5 m
radius is marked around the area to which the audience cannot get access.
The area called “public area” is defined by the space of 3m above the area occupied by the audience and a width of
2.5m around this area. The public area must be clearly identified by signs on the ground.
Inside the public area only a scanning movement is allowed within the terms and conditions defined by the
international technical laser safety report.
The laser unit must be installed out of reach of the audience and at a minimum of 3m above the ground where the
audience is present or protected by a safety perimeter of 5m radius.
The laser unit must be installed in such a way that it can’t be moved under the effect of disruptions such as crowd
movements, vibrations or gusts of wind.
Safety Instructions
Please read these instructions carefully, they include important information about the installation, usage and
maintenance of this product.
• Please keep this User Guide for future reference. If you sell the unit to another user, be sure that he also receives
this instruction booklet.
• Always make sure that you are connecting to the proper voltage, and that the line voltage you are connecting to is
not higher than that stated on the decal or rear panel of the fixture.
• This product is intended for indoor use only!
• To prevent risk of fire or shock, do not expose fixture to rain or moisture. Make sure there are no flammable
materials close to the unit while operating.
• The unit must be installed in a location with adequate ventilation, at least 20in (50cm) from adjacent surfaces. Be
sure that no ventilation slots are blocked.
• Always disconnect from power source before servicing or replacing fuse and be sure to replace with same fuse size
and type.
• Secure fixture to fastening device using a safety chain. Never carry the fixture solely by its head. Use its carrying
handles.
• Maximum ambient temperature (Ta) is 104° F (40°C). Do not operate the fixture at temperatures higher than this.
• In the event of a serious operating problem, stop using the unit immediately. Never try to repair the unit by
yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the nearest
authorized technical assistance center. Always use the same type of spare parts.
• Don’t connect the device to a dimmer pack.
• Make sure the power cord is never crimped or damaged.
• Never disconnect the power cord by pulling or tugging on the cord.
• Avoid direct eye exposure to the light source while it is on.
DISCONNECT DEVICE: Where the MAINS plug or an appliance coupler is used as the disconnect device, the
disconnect device shall remain readily operable.
©Copyright Lotronic 2017
2
LASER EMISSION DATA
* As measured under IEC measurement conditions for classification.
Laser Classification
Class 3B
Green Laser Medium
DPSS 532nm
Red Laser Medium
LD GaAIAs 638nm,typical
Blue Laser Medium
LD InGaN 445nm, typical
Beam Diameter
<3mm at aperture
Divergence(each beam)
<1.3 mrad
Divergence(total light)
<1.3mrad
Transverse Beam Mode
TEM00
Cooling
TEC & Fan Cooling
Scanning
High speed scanner 25kpps
Laser Power :
SCAN500RGB : 100mW-G-532nm+200mW-R-650nm+200mW-B-445nm
SCAN1100RGB: 200mW-G-532nm+300mW-R-638nm+600mW-B-445nm
SCAN2000 RGB: 500mW-G-532nm+500mW-R-638nm+1000mW-B-445nm
SCAN1100PINK: 500mW-R-638nm+600mW-B-445nm
Specification:
Mains Input: ....................................................................................... AC100~240V, 50/60Hz, total 30W
Fuse: .................................................................................................... 250V 2A slow blow (20mm glass)
Menu mode: .............................................. Auto, music, DMX512, Master/slave, ILDA, Artnet RJ45, IRC
Laser Classification: ..................................................................................................................... Class 3B
Laser Safety Standard: ................................................................................................... EN60825-1:2014
Condition Temperature: .......................................................................................................... 10℃~40℃
DMX channels...................................................................................................................5 / 34 channels
Dimensions ................................................................................................................246 x 211 x 105mm
Weight: ............................................................................................................................................ 3.5kg
Installation
The unit should be mounted via its screw holes on the bracket. Always ensure that the unit is firmly fixed to avoid
vibration and slipping while operating. Always ensure that the structure to which you are attaching the unit is secure
and able to support a weight of 10 times of the unit’s weight. Also always use a safety cable that can hold 12 times
the weight of the unit when installing the fixture.
DMX512
1. Install the units in a suitable position (laying or appending).
2. Use standard XLR microphone cable chain your units together via the XLR connector on the rear of the units. For
longer cable runs we suggest a terminator at the last fixture.
3. Assign a DMX address to each the unit.
©Copyright Lotronic 2017
3
4. Turn on all units' power, the units begins reset, then the unit begins working.
5. Use DMX console to control your units.
Operating introduction:
1. Built-in performance programs, AUTO, SOUND
2. DMX mode
3. Master/Slave
4. ILDA DB25 mode
5. Artnet RJ45 mode
Operation:
Mode/Function: Set the operating mode of laser.
Confirmation: Confirms all settings or changes of LED control panel.
UP/DOWN: Changes the operating mode, parameter or DMX address.
Operation description:
Set the function overview:
* [FUNCTION] key:
At every short press on the FUNC button, following actions are active :
- INDR - DMX (5-CH simplified DMX mode) + you can set the DMX address via the UP/DOWN buttons and
confirm with ENTER
- DMX (34-CH advanced DMX mode) + you can set the DMX address via the UP/DOWN buttons and confirm
with ENTER
- INDR SE (1 – 2 – 3) = 3 AUTO or sound-controlled mode. The ENTER button toggles between these 2 modes
(SND is displayed)
The SE 1 sequence (beam/tunnels, waves mode) – SE 2 (animation 1) – SE 3 is accessible via the sub-menu.
To access the sub menu keep the FUNC button pressed for at least 3 seconds. SET is displayed on the bottom right
©Copyright Lotronic 2017
4
side of the display. You are now in the setting menu.
Select the sequence by selecting SE and press ENTER.
This sub-menu also allows to (not recommended for beginners!)
• Configure motors X & Y via dr – X and dr – Y
• Invert motors (SWAP XY)
• Set the projection size (X-SIZ with values from 0 to 100 and Y-SIZE with values from 0 to 100)
• Activate/deactivate the remote control ( REMOTE – ON/OFF)
To leave the menu, keep FUNC pressed.
* Overview of playback modes:
There are multiple playback modes:
- Built-in Master mode: divided into three small playback modes.
>1: mixed playback: Drawing scenes from each sequence in taking turn playback (can be set by setting the
function).
>2: Sequence playback: only play a sequence. (This mode for the temporary mode, restart laser will not
automatically enter)
>3: Scene playback: only play a scene. This mode for the temporary mode, restart laser will not automatically
enter)
- Slave mode: divided into the following two slave modes:
>1: DMX slave mode: Through the DMX signal line to follow the Master to play.
>2: ILDA slave mode: Accept the ILDA signal control from the Master or laser console.
- DMX playback mode:
>1:Easy DMX mode: 5 channels
Note: Simple DMX mode takes the built-in scenes of the laser directly without any further settings.
DMX
CHANNEL
DESCRIPTION
value
0
OFF
CH 1
On/off power
1-255
ON
0-127
AUTO
CH2 Act
auto/sound
128-255 SOUND CONTROLLED
0-15
1 gallery (0)
CH3
16-31
2 gallery (16)
Gallery Menu
32-239
3 gallery (32)
(scenes)
240-255 40 gallery (240)
CH4
Each value corresponds to a pattern, the value exceeds the number of patterns, the
0-255
Scenes
system with the largest number instead
0-31
RGB
32-63
red
64-95
yellow
96-127
green
CH5
colors
128-159 blueviolet
160-191 blue
191-223 purple
224-255 white
©Copyright Lotronic 2017
5
>2:Professional DMX mode: 34 channels
Order 1: Professional DMX mode is available to the experienced lighting engineers, who are professional in DMX
control, as well as the laser pattern scanning principle , if not, pls use simple DMX mode 4 channels
Order 2: DQF6 (the Bluetooth number) is a double-pattern laser system, and two patterns can be scanned at the
same time. The following description is distinguished by pattern A and pattern B. For ease view, the following points
are shown in Table 1 and Table 2 respectively below.
Table 1 (PATTERN A):
Note:Table 1: CH1-Ch17,pattern A’s channel function, except for special instructions, only control the pattern A,
pattern B is not controlled by this 17 channels:
CHANNEL
DMX value
DESCRIPTION
0
OFF
1-99
ON
CH 1
100-199
AUTO
On/off power
200-254
retain
255
Pattern A closed light, pattern B output light
0-49
Out of bounds
50-99
Reentry
CH2
100-149
blanking
Out of bounds and pattern size
150-199
Blanking+ pattern enlarge
200-255
retain
0-15
1 gallery (0)
16-31
2 gallery (16)
CH3
Gallery Menu (sences)
32-239
3 gallery (32)
240-255
40 gallery (240)
Each value corresponds to a pattern, when the value
CH4
0-255
exceeds the number of patterns, the system uses the
Gallery choose
largest number
0
No zooming
1-31
Zooming 1
32-63
Zooming 2
64-95
Zooming3
CH5
96-127
Zooming4
Patterns zooming
128-159
Zooming 5
160-191
Zooming 6
192-223
Zooming 7
224-255
Zooming8
0-63
Manual rotating
64-95
Rotating 1
96-127
Rotating 2
CH6
128-159
Rotating 3
Patterns rotating
160-191
Rotating 4
192-223
Rotating 5
224-255
Rotating 6
0-63
Manual moving
CH7
64-95
Horizontal 1
Horizontal moving
96-127
Horizontal 2
©Copyright Lotronic 2017
6
CH8
Vertical moving
CH9
X axis
Horizontal zooming
CH10
Y axis vertical zooming
CH11
Force Segmentation Color
CH12
Patterns discolor
CH13
Node and blanking control
CH14
©Copyright Lotronic 2017
128-159
160-191
192-223
224-255
0-63
64-95
96-127
128-159
160-191
192-223
224-255
0-63
64-95
96-127
128-159
160-191
192-223
224-255
0-63
64-95
96-127
128-159
160-191
192-223
224-255
0
1-255
0-7
8-15
16-23
24-31
32-39
40-47
48-55
56-63
64-95
96-127
128-159
160-191
192-223
224-255
0-63
64-127
128-159
160-255
0-63(CH15)
Horizontal 3
Horizontal 4
Horizontal 5
Horizontal 6
Manual moving
vertical 1
vertical 2
vertical 3
vertical 4
vertical 5
vertical 6
Manual X zooming
X zooming 1
X zooming 2
X zooming 3
X zooming 4
X zooming 5
X zooming 6
Manual Y zooming
Y zooming 1
Y zooming 2
Y zooming 3
Y zooming 4
Y zooming 5
Y zooming 6
Patterns original colors
The length of the segmented colors
original
red
yellow
green
blueviolet
blue
purple
white
Red/green/blue discolor
Blueviolut/blue/purple discolor
7 colors discolor
RGB discolor
Positive walking color
Reverse walking color
Normal blanking control
Patterns without blanking,flyback line banking
Patterns and line without blanking
retain
Manual gradually drawing
7
The auxiliary function of the drawing
control (used in conjunction with
CH15)
CH15
Progressive control
[CH15 must be used in conjunction
with CH14]
64-127/160191(CH15)
192-255
0-31
32-63
64-95
96-127
128-159
160-191
192-223
224-255
CH16 Auxiliary control of twist
deformation effect channel
0-255
CH17
Grating selection and projection
amplitude control
0-255
The moving time of the pattern drawing gradually
The number of nodes that are drawn
Forward hand-drawn gradually
Reverse manual drawing
Extended drawing
Contraction drawing
Both ends are zoomed at the same time
Head and tail were zooming
Walking drawing
Turn over drawing
0-255, the greater the value, the smaller the distortion.
[Note: CH16 can control the degree of twist of the twist
effect when zooming, rotating, moving, and twisting
effects]
[0-19,grating 1] [20-39,grating 2].....[220-239,grating 12]
[240-255,grating 13]
Note: In each paragraph, the larger the value, the smaller
the projection range
Table 2 (PATTERN B):
Note: Table 2: CH18-CH34, pattern B’s channel function, except for special instructions, only control the pattern B,
pattern A is not controlled by these 17 channels.
In order to simplify the operation, the functions correspond to pattern A, only special green parts are different.
CHANNEL
DMX value
DESCRIPTION
0
off working
1-99
Act auto
CH 18
100-199
Act sound
On/off power
200-254
retain
255
Pattern A closed light, pattern B output light
0-49
Out of bounds
50-99
Reentry
CH19
Out of bounds and pattern size
100-149
blanking
150-255
retain
the smaller the value of the segment, the larger the
0-99
angular distribution of each unit, the gap is a positive
gap
CH20
The distribution angle of each unit of the
the smaller the value of the segment, the larger the
array
100-199
angle distribution of each unit, the gap is the negative
gap
200-255
retain
Each value corresponds to a pattern, when the value
CH21
0-255
exceeds the number of patterns, the system uses the
Gallery choose
largest number
0
No zooming
CH22
1-31
Zooming 1
Patterns zooming
32-63
Zooming 2
©Copyright Lotronic 2017
8
CH23
Patterns rotating
CH24
Horizontal moving
CH25
Vertical moving
CH26
X axis
Horizontal zooming
CH27
Y axis vertical zooming
CH28
Force Segmentation Color
CH29
Patterns discolor
©Copyright Lotronic 2017
64-95
96-127
128-159
160-191
192-223
224-255
0-63
64-95
96-127
128-159
160-191
192-223
224-255
0-63
64-95
96-127
128-159
160-191
192-223
224-255
0-63
64-95
96-127
128-159
160-191
192-223
224-255
0-63
64-95
96-127
128-159
160-191
192-223
224-255
0-63
64-95
96-127
128-159
160-191
192-223
224-255
0
1-255
0-7
8-15
16-23
24-31
Zooming3
Zooming4
Zooming 5
Zooming 6
Zooming 7
Zooming8
Manual rotating
Rotating 1
Rotating 2
Rotating 3
Rotating 4
Rotating 5
Rotating 6
Manual moving
Horizontal 1
Horizontal 2
Horizontal 3
Horizontal 4
Horizontal 5
Horizontal 6
Manual moving
vertical 1
vertical 2
vertical 3
vertical 4
vertical 5
vertical 6
Manual X zooming
X zooming 1
X zooming 2
X zooming 3
X zooming 4
X zooming 5
X zooming 6
Manual Y zooming
Y zooming 1
Y zooming 2
Y zooming 3
Y zooming 4
Y zooming 5
Y zooming 6
Patterns original colors
The length of the segmented colors
original
red
yellow
green
9
CH30
Node and blanking control
Array control
32-39
40-47
48-55
56-63
64-95
96-127
128-159
160-191
192-223
224-255
0-63
64-127
128-159
160-191
192-255
CH31
The auxiliary function of the drawing
control (used in conjunction with CH32)
CH32
Progressive control
[CH32 must be used in conjunction with
CH31]
When the pattern A is voice-activated,
the CH32 action will also become a
voice-activated state
0-63(CH32)
64-127/160191(CH32)
192-255
(CH32)
0-31
32-63
64-95
96-127
128-159
160-191
192-223
224-255
CH33 Auxiliary control of twist
deformation effect channel
0-255
CH34
projection amplitude control
0-255
blueviolut
blue
purple
white
Red/green/blue discolor
Blueviolut/blue/purple discolor
7 colors discolor
RGB discolor
Positive walking color
Reverse walking color
Normal blanking control
Patterns without blanking,flyback line banking
Patterns and line without blanking
Pattern A anchored in an array pattern of pattern B,
pattern color setting same with A
Pattern A anchored in an array pattern of pattern B,
pattern color setting same with B
Manual gradually drawing
The moving time of the pattern drawing gradually
The number of nodes that are drawn
Forward hand-drawn gradually
Reverse manual drawing
Extended drawing
Contraction drawing
Both ends are zoomed at the same time
Head and tail were zooming
Walking drawing
Turn over drawing
0-255, the greater the value, the smaller the distortion.
[Note: CH33 can control the degree of twist of the twist
effect when zooming, rotating, moving, and twisting
effects]
(0-19),(20-39).....(220-239) , (240-239),(240-255)
Note: In each paragraph, the larger the value, the
smaller the projection range
>3: ILDA console mode: ILDA signal input, output ILDA effect.
* Effects library: Each effect library is stored as a sequence on the motherboard, they are:
1: Geometric sequence (Gypsophalange filter);
2: wedding theme sequence;
3: Christmas theme sequence;
4: beam sequence (no filter);
5: Geometric sequence (Galaxy Nebula);
6: 3D sequence (3D filter);
7: point circle sequence (dot circle filter);
8: long virtual point sequence (long virtual point filter);
©Copyright Lotronic 2017
10
LED display instruction:
* {INTR}{DMX}{APP}{SET}{SND}{SEL} for status identification.
- {INTR} Indicates that the fixture is using the built-in effect. When the status flag is lit (INTR} alone, it is the built-in
effect play mode.
- {DMX} indicates that the fixture is controlled by the DMX signal. The status flag is only bright (DMX) for the
standard DMX control mode
- {INTR} {DMX} is a simple DMX mode that calls the built-in scenario via DMX signals.
- {SET} indicates that the fixture is in the system setup state.
- {SND} indicates that the motion of the pattern is controlled by the sound when the fixture is in the built-in mode.
- {SEL} In the set state, the indicator is lit to indicate that the current setting option is enabled.
* {INTR} the state of the digital display section.
- {AL} indicates the mix mode in the built-in mode (the scene play is extracted from each sequence).
- {P ###} Indicates the scene playback mode when the built-in mode is displayed. The displayed value is the scene
number.
- {SE ##} indicates the sequence playback mode when the built-in mode is displayed, and the displayed value is the
sequence number.
* DMX} the digital display part state.
* {INTR} + {DMX}the digital display part state.
- {A ###} Indicates the DMX address code for the fixture.
* {SET} the digital display part state.
- {SE ##} Indicates whether the digital display sequence is selected when the mixed mode of the built-in mode is
used.
(Note: {SEL} status flag indicates whether the sequence is selected.)
- {DR- ||} indicates the X mirror setting.
- {DR- =} represents the Y mirror setting.
- {DR- = ||} represents XY offset.
- {x ###} represents the X projection amplitude, the digital part is the full scale percentage value
(Note: {SEL} can be adjusted through the button on the board).
- {y ###} denotes the Y projection amplitude (Note: same as above).
- {r0FF} Indicates whether or not the remote control function is turned off.
- The virtual remote control of the mobile phone APP is the same as that described in the previous section.
* Extinguished: After a few hours of no operation, the digital part of the display will go out (Note: the screen function
with the specific model, some models do not have the function)
Remote control mode:
* [INTR] key: Enter the mix mode built-in.
* [DMX] key: Professional DMX mode.
* [E-DMX] key: easy DMX mode.
*[1-9] key: digital number from 1 to 9
- In the built-in mix mode, press the [1-9] button to enter the scene playback mode. The
number entered is the scene
- When the built-in sequence is played, press the [1-9] button to select the serial number.
- In DMX mode or E- DMX mode, press the digital button to set the address code.
- In the setting mode, you can select the projection range when setting the projection
angle.
* [+][-] key:
- In the scene playback mode, press this key to adjust the scene number.
- Press this key to adjust the serial number in the sequence play mode.
©Copyright Lotronic 2017
11
- In DMX or E- DMX mode, press this key to adjust the address code.
- When setting mode, press this key to adjust the setting item.
* [SET]key:
- When the system is not in the set state, press 5 times to enter the system setting state.
- When the system is in the setting state, press this key to exit the system setting state.
* [RGB] key:
-Press this key to toggle the pattern color. When the color is changed, the display will temporarily display the
currently set color.
- This setting is set to temporary, and the system will return to the color state (CLR) after the shutdown is
restarted.
* [SEQ] key: Press this key to enter the sequence playback mode in built-in mode.
* [B-Out] key: Press this key to turn off the laser output.
* [Sound] key:
- In the built-in mode, press this key to set or cancel the voice.
- When setting a mixed sequence, you can select or cancel a sequence.
- You can select or cancel the mirror when setting the graphic X mirror, the graphic Y mirror, and the XY for the
graphic.
- You can select or cancel the remote control when setting the remote control function.
* [ENTER] key: When entering a number, the value to be entered is less than 100, press this key to speed up the
digital input.
IMPORTANT NOTE: Electric products must not be put into household waste. Please bring them to a recycling centre. Ask
your local authorities or your dealer about the way to proceed.
F
LASER A USAGE EXCLUSIVEMENT PROFESSIONNEL
Ce laser est conforme aux normes EN60825-1:2014, il est à usage
exclusivement professionnel,
Son installation et utilisation doit être effectué exclusivement par
un technicien compétent et formé aux risques spécifiques des
lasers.
RAPPEL DES PRECAUTIONS DE SECURITE
Les appareils à lasers de classe 3 et 4, sont utilisables exclusivement en plein air
A l'intérieur de la zone réservée au public, aucun " tir laser " n'est admis en direction du public, quelle que soit la
classe du laser, sauf si un périmètre d'exclusion du public de 5 mètres de rayon, matérialisé, est mis en place.
La zone dite " zone réservée au public " est définie par l'espace situé jusqu'à 3 mètres au-dessus de la surface
occupée par le public et sur une bande de 2, 5 mètres autour de cette dernière. La zone réservée au public est
matérialisée au sol.
Dans la zone réservée au public, seul est admis un rayonnement par balayage effectué dans les conditions fixées par
le rapport technique international sur la sécurité des appareils à laser
L'appareil à laser est hors de portée du public et au minimum à 3 mètres au-dessus du sol accessible au public ou
protégé par un périmètre de sécurité de 5 mètres de rayon.
L'appareil laser doit être fixé/posé de telle manière qu'il ne puisse pas être déplacé sous l'effet de perturbations
telles que des mouvements de foule, des vibrations ou des rafales de vent.
©Copyright Lotronic 2017
12
Consignes de sécurité
Lisez attentivement ce manuel qui contient des informations importantes sur l’installation, l’utilisation et l’entretien
de cet appareil.
• Conservez le manuel pour référence ultérieure. Si l’appareil change un jour de propriétaire, assurez-vous que le
nouvel utilisateur est en possession du manuel.
• Assurez-vous que la tension secteur convient à cet appareil et qu’elle ne dépasse pas la tension d’alimentation
indiqué sur la plaque signalétique de l’appareil.
• Uniquement pour utilisation à l’intérieur!
• Afin d’éviter tout risque d’incendie ou de choc électrique, ne pas exposer cet appareil à la pluie ou à l’humidité.
Assurez-vous qu’aucun objet inflammable ne se trouve à proximité de l’appareil pendant son fonctionnement.
• Installez l’appareil à un endroit bien ventilé à une distance minimum de 50cm de toute surface. Assurez-vous que
les fentes de ventilation ne sont pas bloquées.
• Débranchez l’appareil du secteur avant toute manipulation ou entretien. Lorsque vous remplacez le fusible, utilisez
uniquement un fusible qui présente exactement les mêmes caractéristiques que l’ancien.
• La température ambiante ne doit pas dépasser 40°C. Ne pas faire fonctionner l’appareil à des températures
supérieures.
• En cas de dysfonctionnement, arrêtez immédiatement l’appareil. N’essayez jamais de réparer l’appareil par vousmême. Une réparation mal faite peut entraîner des dommages et des dysfonctionnements. Contactez un service
technique agréé. Utilisez uniquement des pièces détachées identiques aux pièces d’origine.
• Ne pas brancher l’appareil sur un variateur.
• Assurez-vous que le cordon d’alimentation n’est jamais écrasé ni endommagé.
• Ne pas exposer vos yeux à la source lumineuse.
• Lorsque le cordon d'alimentation ou un coupleur d'appareil est utilisé comme dispositif de déconnexion, ce
dispositif doit rester facilement accessible;
Si un interrupteur omnipolaire est utilisé comme dispositif de déconnexion, l'emplacement sur l'appareil et la
fonction de l'interrupteur doit être décrite, et le commutateur doit rester facilement accessible
LASER EMISSION DATA
* As measured under IEC measurement conditions for classification.
Classification Laser
Classe 3B
Laser vert
DPSS 532nm
Laser rouge
LD GaAIAs 638nm, typique
Laser Bleu
LD InGaN 445nm, typique
Diamètre du rayon
<3mm à la sortie
Divergence (chaque rayon) <1.3 mrad
Divergence (total)
<1.3mrad
Transverse Beam Mode
TEM00
Puissance des lasers
Refroidissement
SCAN500RGB : 100mW-G-532nm+200mW-RBalayage
650nm+200mW-B-445nm
SCAN1100RGB: 200mW-G-532nm+300mW-R638nm+600mW-B-445nm
SCAN2000 RGB: 500mW-G-532nm+500mW-R-638nm+1000mW-B-445nm
SCAN1100PINK: 500mW-R-638nm+600mW-B-445nm
©Copyright Lotronic 2017
TEC & ventilateur
Scanner haute vitesse 25kpps
13
Caractéristiques techniques:
Alimentation.......................................................................................................... AC100-240V, 50/60Hz
Fusible ..........................................................................................................250V 2 A lent (verre 20mm)
Modes: ....................................................Auto, musique, DMX512, Master/slave, ILDA, télécommande
Laser Classification: ..................................................................................................................... Class 3B
Laser Safety Standard: ................................................................................................... EN60825-1:2014
Condition Temperature: .......................................................................................................... 10℃~40℃
Canaux DMX ....................................................................................................................... 5 / 34 canaux
Dimensions ................................................................................................................246 x 211 x 105mm
Poids: ............................................................................................................................................... 3.5kg
Montage
Fixez l’appareil sur l’étrier au moyen des trous de vis. Assurez-vous que l’appareil est solidement fixé afin d’éviter des
vibrations et des mouvements pendant le fonctionnement. Vérifiez que le support sur lequel vous allez installer
l’appareil est solide et capable de supporter au moins 10 fois le poids de l’appareil. Lors de l’installation utilisez
toujours un câble de sécurité supplémentaire qui peut porter 12 fois le poids le d’appareil.
DMX512
1. Installez les appareils dans une position appropriée (couché ou suspendu).
2. Reliez les appareils avec un câble XLR standard de microphone par les connecteurs XLR au dos. En cas de chaînes
plus longues, nous recommendons l’emploi d’une résistance de fin de ligne sur le dernier appareil. U
3. Affectez une adresse DMX à chaque appareil.
4. Mettez tous les appareils sous tension. Ils effectuent d’abord un reset et sont ensuite opérationnels.
5. Commandez les appareils avec une console DMX.
Description:
Fonction de réglage:
Chaque pression courte sur le bouton FUNC effectue les actions suivantes :
- INDR - DMX (mode dmx simplifié 5 canaux) + possibilité de réglage de l’adresse DMX via les boutons UP /
DOWN et valider avec bouton ENTER
- DMX (mode DMX étendu 34 canaux) + possibilité de réglage de l’adresse DMX via les boutons UP / DOWN et
valider avec bouton ENTER
- INDR SE (1 – 2 – 3) = 3 modes Auto ou son. Dans ce mode en appuyant sur le bouton ENTER on bascule entre
le mode auto et le mode son (SND sur l’écran)
La séquence SE 1 (mode beam/tunnels, vagues) – SE 2 (animation 1) – SE 3 peut être choisie vie le sous menu.
Pour accèder au sous menu, il faut appuyer longuement sur le bouton FUNC (3 secondes) le mot SET apparait alors
en bas à droite de l’écran, vous êtes mainenant dans le menu d’ajustement.
On peut alors choisir la séquence en se mettant sur SE et en appuyant sur ENTER. Ensuite choisir la séquence en
utilisant UP/DOWN puis réappuyer sur ENTER pour valider
On peut également via ce sous menu ( déconseiller à l’utilisateur débutant) :
- Parametrer les moteurs X et Y via dr – X et dr – Y
- Inverser le sens des moteurs (SWAP XY)
- Régler la taille de projection (X-SIZE avec valeur de 0 à 100 et Y-SIZE avec valeur de 0 à 100)
- Activer / désactiver la télécommande ( REMOTE – ON/OFF)
Pour quitter ce sous menu il faut réappuyer longuement sur FUNC.
©Copyright Lotronic 2017
14
Mode DMX simplifié à 5 Canaux
Note: Dans ce mode, les scenes intégrées sont utilisées telles quelles sont autre réglage. S
CANAL
Valeur DMX
DESCRIPTION
0
OFF
CH 1
On/off power
1-255
ON
0-127
AUTO
CH2 Act
auto/sound
128-255
SOUND CONTROLLED
0-15
1 gallery (0)
CH3
16-31
2 gallery (16)
Gallery Menu
32-239
3 gallery (32)
(scenes)
240-255
40 gallery (240)
CH4
Each value corresponds to a pattern, the value exceeds the number of
0-255
Scenes
patterns, the system with the largest number instead
0-31
RGB
32-63
red
64-95
yellow
96-127
green
CH5
colors
128-159
blueviolet
160-191
blue
191-223
purple
224-255
white
Mode professionnel à 34 Canaux RESERVE AUX PROFESSIONNELS AVERTIS
Order 1: Professional DMX mode is available to the experienced lighting engineers, who are professional in DMX
Table 1 (PATTERN A):
Note:Table 1: CH1-Ch17,pattern A’s channel function, except for special instructions, only control the pattern A,
pattern B is not controlled by this 17 channels:
CHANNEL
DMX value
DESCRIPTION
0
OFF
1-99
ON
CH 1
100-199
AUTO
On/off power
200-254
retain
255
Pattern A closed light, pattern B output light
0-49
Out of bounds
50-99
Reentry
CH2
100-149
blanking
Out of bounds and pattern size
150-199
Blanking+ pattern enlarge
200-255
retain
0-15
1 gallery (0)
16-31
2 gallery (16)
CH3
Gallery Menu (sences)
32-239
3 gallery (32)
240-255
40 gallery (240)
Each value corresponds to a pattern, when the value
CH4
0-255
exceeds the number of patterns, the system uses the
Gallery choose
largest number
©Copyright Lotronic 2017
15
CH5
Patterns zooming
CH6
Patterns rotating
CH7
Horizontal moving
CH8
Vertical moving
CH9
X axis
Horizontal zooming
CH10
Y axis vertical zooming
CH11
Force Segmentation Color
CH12
©Copyright Lotronic 2017
0
1-31
32-63
64-95
96-127
128-159
160-191
192-223
224-255
0-63
64-95
96-127
128-159
160-191
192-223
224-255
0-63
64-95
96-127
128-159
160-191
192-223
224-255
0-63
64-95
96-127
128-159
160-191
192-223
224-255
0-63
64-95
96-127
128-159
160-191
192-223
224-255
0-63
64-95
96-127
128-159
160-191
192-223
224-255
0
1-255
0-7
No zooming
Zooming 1
Zooming 2
Zooming3
Zooming4
Zooming 5
Zooming 6
Zooming 7
Zooming8
Manual rotating
Rotating 1
Rotating 2
Rotating 3
Rotating 4
Rotating 5
Rotating 6
Manual moving
Horizontal 1
Horizontal 2
Horizontal 3
Horizontal 4
Horizontal 5
Horizontal 6
Manual moving
vertical 1
vertical 2
vertical 3
vertical 4
vertical 5
vertical 6
Manual X zooming
X zooming 1
X zooming 2
X zooming 3
X zooming 4
X zooming 5
X zooming 6
Manual Y zooming
Y zooming 1
Y zooming 2
Y zooming 3
Y zooming 4
Y zooming 5
Y zooming 6
Patterns original colors
The length of the segmented colors
original
16
Patterns discolor
CH13
Node and blanking control
CH14
The auxiliary function of the drawing
control (used in conjunction with
CH15)
CH15
Progressive control
[CH15 must be used in conjunction
with CH14]
8-15
16-23
24-31
32-39
40-47
48-55
56-63
64-95
96-127
128-159
160-191
192-223
224-255
0-63
64-127
128-159
160-255
0-63(CH15)
64-127/160191(CH15)
192-255
0-31
32-63
64-95
96-127
128-159
160-191
192-223
224-255
CH16 Auxiliary control of twist
deformation effect channel
0-255
CH17
Grating selection and projection
amplitude control
0-255
red
yellow
green
blueviolet
blue
purple
white
Red/green/blue discolor
Blueviolut/blue/purple discolor
7 colors discolor
RGB discolor
Positive walking color
Reverse walking color
Normal blanking control
Patterns without blanking,flyback line banking
Patterns and line without blanking
retain
Manual gradually drawing
The moving time of the pattern drawing gradually
The number of nodes that are drawn
Forward hand-drawn gradually
Reverse manual drawing
Extended drawing
Contraction drawing
Both ends are zoomed at the same time
Head and tail were zooming
Walking drawing
Turn over drawing
0-255, the greater the value, the smaller the distortion.
[Note: CH16 can control the degree of twist of the twist
effect when zooming, rotating, moving, and twisting
effects]
[0-19,grating 1] [20-39,grating 2].....[220-239,grating 12]
[240-255,grating 13]
Note: In each paragraph, the larger the value, the smaller
the projection range
Table 2 (PATTERN B):
Note: Table 2: CH18-CH34, pattern B’s channel function, except for special instructions, only control the pattern B,
pattern A is not controlled by these 17 channels.
In order to simplify the operation, the functions correspond to pattern A, only special green parts are different.
CHANNEL
DMX value
DESCRIPTION
0
off working
1-99
Act auto
CH 18
On/off power
100-199
Act sound
200-254
retain
©Copyright Lotronic 2017
17
CH19
Out of bounds and pattern size
255
0-49
50-99
100-149
150-255
0-99
CH20
The distribution angle of each unit of the
array
100-199
200-255
CH21
Gallery choose
CH22
Patterns zooming
CH23
Patterns rotating
CH24
Horizontal moving
CH25
Vertical moving
CH26
X axis
©Copyright Lotronic 2017
0-255
0
1-31
32-63
64-95
96-127
128-159
160-191
192-223
224-255
0-63
64-95
96-127
128-159
160-191
192-223
224-255
0-63
64-95
96-127
128-159
160-191
192-223
224-255
0-63
64-95
96-127
128-159
160-191
192-223
224-255
0-63
64-95
Pattern A closed light, pattern B output light
Out of bounds
Reentry
blanking
retain
the smaller the value of the segment, the larger the
angular distribution of each unit, the gap is a positive
gap
the smaller the value of the segment, the larger the
angle distribution of each unit, the gap is the negative
gap
retain
Each value corresponds to a pattern, when the value
exceeds the number of patterns, the system uses the
largest number
No zooming
Zooming 1
Zooming 2
Zooming3
Zooming4
Zooming 5
Zooming 6
Zooming 7
Zooming8
Manual rotating
Rotating 1
Rotating 2
Rotating 3
Rotating 4
Rotating 5
Rotating 6
Manual moving
Horizontal 1
Horizontal 2
Horizontal 3
Horizontal 4
Horizontal 5
Horizontal 6
Manual moving
vertical 1
vertical 2
vertical 3
vertical 4
vertical 5
vertical 6
Manual X zooming
X zooming 1
18
Horizontal zooming
CH27
Y axis vertical zooming
CH28
Force Segmentation Color
CH29
Patterns discolor
CH30
Node and blanking control
Array control
96-127
128-159
160-191
192-223
224-255
0-63
64-95
96-127
128-159
160-191
192-223
224-255
0
1-255
0-7
8-15
16-23
24-31
32-39
40-47
48-55
56-63
64-95
96-127
128-159
160-191
192-223
224-255
0-63
64-127
128-159
160-191
192-255
CH31
The auxiliary function of the drawing
control (used in conjunction with CH32)
CH32
Progressive control
[CH32 must be used in conjunction with
CH31]
When the pattern A is voice-activated,
the CH32 action will also become a
voice-activated state
©Copyright Lotronic 2017
0-63(CH32)
64-127/160191(CH32)
192-255
(CH32)
0-31
32-63
64-95
96-127
128-159
160-191
192-223
X zooming 2
X zooming 3
X zooming 4
X zooming 5
X zooming 6
Manual Y zooming
Y zooming 1
Y zooming 2
Y zooming 3
Y zooming 4
Y zooming 5
Y zooming 6
Patterns original colors
The length of the segmented colors
original
red
yellow
green
blueviolut
blue
purple
white
Red/green/blue discolor
Blueviolut/blue/purple discolor
7 colors discolor
RGB discolor
Positive walking color
Reverse walking color
Normal blanking control
Patterns without blanking,flyback line banking
Patterns and line without blanking
Pattern A anchored in an array pattern of pattern B,
pattern color setting same with A
Pattern A anchored in an array pattern of pattern B,
pattern color setting same with B
Manual gradually drawing
The moving time of the pattern drawing gradually
The number of nodes that are drawn
Forward hand-drawn gradually
Reverse manual drawing
Extended drawing
Contraction drawing
Both ends are zoomed at the same time
Head and tail were zooming
Walking drawing
19
224-255
Turn over drawing
0-255, the greater the value, the smaller the distortion.
CH33 Auxiliary control of twist
[Note: CH33 can control the degree of twist of the twist
0-255
deformation effect channel
effect when zooming, rotating, moving, and twisting
effects]
(0-19),(20-39).....(220-239) , (240-239),(240-255)
CH34
0-255
Note: In each paragraph, the larger the value, the
projection amplitude control
smaller the projection range
* Bibliothèque d’effets: Chaque librairie est sauvegardé en tant que sequence sur la carte-mère:
1: Séquences géométriques(Gypsophalange filter);
2: Thème Mariage
3: Thème Noël
4: Rayons (sans filter)
5: Séquence géométique (Galaxy Nebula);
6: Séquences 3D (3D filter);
7: Séquences points- cercles (dot circle filter);
8: Longue sequence point virtuel (long virtual point filter);
Télécommande
* [INTR] key: Mode automatique intégré.
* [DMX] key: DMX professionnel.
* [E-DMX] key: DMX simplifié.
*[1-9] key: pave numérique
- En mode INTR, appuyez sur une touche [1-9] pour aller en mode de lecture d’une
scène. Le chiffre entré correspoond à une scène
- En mode DMX ou E- DMX, appuyez sur les touches pour entrer l’adresse DMX.
-en mode de réglage vous povuez sélectioner la distance de projection lors du
réglage de l’angle de projection.
* [+][-]:
- En mode lecture de scène, appuyez pour ajuster le numéro de scène.
- En mode DMX ou E- DMX appuyez pour adjuster l’adresse DMX.
* [SET]:
- Si l’appareil n’est pas en mode de réglage, appuyez 5 fois pour entrer en mode
de réglage
- Lorsque l’appareil est en mode de régalge, appuyez pour quitter le mode de
réglage.
* [RGB]:
-Sélection de la couleur
* [SEQ]: En mode automatique, entrer en mode lecture d’une séquence.
* [B-Out]: Eteint le laser
* [Sound]:
- En mode auto, appuyez pour régler ou annuler la sensibilité audio.
- Lors du réglage d’une séquence mixte, vous pouvez sélectionner ou annuler une séquence.
- Vous pouvez sélectionner ou annuler un mirroir lorsque vous réglez le mirroir graphique X, Y ou XY.
- Vous pouvez activer ou déactiver la télécommande lorsque vous en en mode réglage de la télécommande.
* [ENTER]: Lorsque vous entrez un chiffre et la valeur à entrer est inférieureà 100, appuyez pour accéler.
NOTE IMPORTANTE : Les produits électriques ne doivent pas être mis au rebut avec les ordures ménagères. Veuillez les faire recycler là où il existe des
centres pour cela. Consultez les autorités locales ou votre revendeur sur la façon de les recycler.
©Copyright Lotronic 2017
20
Download PDF