ELITE PLASMA DISPLAY RS-232C Control PR0

ELITE PLASMA DISPLAY
RS-232C Control
PR0-1110HD & PRO-910HD
March 2005
RS232C Control for Pioneer Plasma Displays
1. Communication conditions
1.1 Communication mode
The default communication mode for many of the newer displays is SR+ mode. In this mode the display will not
receive RS232C commands.
Before using RS232C control you must set the communication mode.
The remote control can be used to change the communication mode.
(Note) RS232C control and SR+ function cannot be used simultaneously.
1.2 Communication mode and baud rate selection
1.2.1 Communication mode and baud rate selected by Integrator menu
Push Menu key then push Power key within 3 seconds. The Integrator Menu will appear similar to this picture.
INTEGRATOR MENU
UART SELECT <=>
9600-232C
In this menu the user can change the communication mode and baud rate using the Left and Right keys.
UART SELECT: 9600bps(SR+)/1200bps/2400bps4800bps/9600bps(232C)/19200bps/38400bps
Push the Menu key to close the Integrator Menu and return to normal operation.
1.3 RS-232C Cable & Communication Settings
All plasma display models EXCEPT the PRO-1410HD use a Straight or Pass-Through Cable
2
2. Communication procedure
Send control commands from a compute via the RS-232C connection.
The display operates according to the received command and sends a response message to the computer.
Do not send multiple commands at the same time. Wait until the computer receives the OK response before
sending the next command.
2.1 Command Format with parameter
These are examples and may not apply specifically to the model that you are controlling: please check the
model specific control charts that follow.
02h
*
STX
*
ID
STX
ID
Command
Parameter
ETX
Parameter
Parameter
000~999
Upn
DWn
C1
C2
C3
P1
Command 3-digite
P2
P3
03h
Parameter 3-digit ETX
Start condition (fixed value 02h)
Fixed value **
3byte (ASCII)
3byte (ASCII)
Stop condition (fixed value 03h)
Description
Up n step
Down n step
Command example
Up volume 1 step: 02, **, VOL, UP1, 03
02h
*
*
V
O
L
Set volume at 10: 02, **, VOL, 010, 03
02h
*
*
V
O
L
U
P
1
03h
0
1
0
03h
2.2 Command Format without parameter
02h
*
STX
*
ID
STX
ID
Command
ETX
C1
C2
C3
Command 3-digit
03h
ETX
Start condition (fixed value 02h)
Fixed value **
3byte (ASCII)
Stop condition (fixed value 03h)
Command example
Power On: 02, **, PON, 03
02h
*
*
P
O
N
03h
2
03h
Select INPUT 2: 02, **, IN2, 03
02h
*
*
I
N
2.5 Restriction
1. GUI is not displayed about the operation when using RS232C.
2. Last memory is not carried out about the operation by RS232C.
3. When input selection is performed by RS232C command (IN1…IN5/INA) PIP is canceled and the single screen
display of the input that was chosen appears..
3
3. Commands for PRO-1110/910HD
Command
PON
POF
IN1
IN2
IN3
IN4
IN5
INA
INB
INC
ING
VOL
AMN
AMY
CHN
SM0
SM1
SM2
SM3
SM4
SM5
SM8
BR0
BR1
BR2
BR3
BR4
BR5
BR6
Parameter
Description
Power On
Power Off
Select INPUT 1
Select INPUT 2
Select INPUT 3
Select INPUT 4
Select PC
001~125
Select Analog TV
001~125
Select Analog TV
001~125 001~999 Select Digital TV (Parameters are Major channel and Minor
channel.)
Select i Link input
000~060
Adjust audio volume
UPn/DWn
Mute Off
Mute On
UP1/DW1
Change TV channel (Up and Down by 1step only)
Screen mode: DOTbyDOT (PC only)
Screen mode: 4:3
Screen mode: FULL
Screen mode: ZOOM (Except PC and HD)
Screen mode: CINEMA (Except PC and HD)
Screen mode: WIDE (Except PC and HD)
Screen mode: FULL2(PC and HD only)
Set baud rate at 9600bps and communication mode at SR+ mode
Set baud rate at 1200bps (RS232C mode)
Set baud rate at 2400bps (RS232C mode)
Set baud rate at 4800bps (RS232C mode)
Set baud rate at 9600bps (RS232C mode)
Set baud rate at 19200bps (RS232C mode)
Set baud rate at 38400bps (RS232C mode)
4
Download PDF
Similar pages