Intel® Server Board S2600KP Product Family and Intel® Compute

Intel® Server Board S2600KP Product
Family and Intel® Compute Module
HNS2600KP Product Family
Technical Product Specification
Revision 1.34
June 2016
Intel® Server Boards and Systems
Revision History
Technical Product Specification
Revision History
Date
Revision
Number
Modifications
1.00
1st External Public Release
January, 2015
1.10
Added 12G SAS bridge boards
Updated BMC Sensor Table
Deleted Appendix Node Manager 2.0 IPMI Integrated Sensors
Added POST Error Beep Codes
March, 2015
1.11
Added maximum RPM for BMC fan control
August, 2015
1.20
Corrected the InfiniBand* Connect-IB* name
Removed the 6G SAS bridge board (option1) from the support list
November, 2015
1.21
Updated the product code
Corrected pin-out tables references
March, 2016
1.30
Added support for Intel® Xeon® processor E5-2600 v4 product family
Added AHWKPTP12GBGBIT
April, 2016
1.31
Added FXX2130PCRPS Power Supply
April, 2016
1.32
Added J6B4 jumper
May, 2016
1.33
Added BBS2600KPTR TPM references
June, 2016
1.34
Added H2312XXLR2 and H2216XXLR2 references
September, 2014
ii
Revision 1.34
Technical Product Specification
Disclaimers
Disclaimers
Information in this document is provided in connection with Intel® products. No license, express or implied, by
estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Intel's
Terms and Conditions of Sale for such products, Intel assumes no liability whatsoever, and Intel disclaims any
express or implied warranty, relating to sale and/or use of Intel products including liability or warranties relating to
fitness for a particular purpose, merchantability, or infringement of any patent, copyright or other intellectual
property right. Intel products are not intended for use in medical, lifesaving, or life sustaining applications. Intel
may make changes to specifications and product descriptions at any time, without notice.
A "Mission Critical Application" is any application in which failure of the Intel Product could result, directly or
indirectly, in personal injury or death. SHOULD YOU PURCHASE OR USE INTEL'S PRODUCTS FOR ANY SUCH
MISSION CRITICAL APPLICATION, YOU SHALL INDEMNIFY AND HOLD INTEL AND ITS SUBSIDIARIES,
SUBCONTRACTORS AND AFFILIATES, AND THE DIRECTORS, OFFICERS, AND EMPLOYEES OF EACH, HARMLESS
AGAINST ALL CLAIMS COSTS, DAMAGES, AND EXPENSES AND REASONABLE ATTORNEYS' FEES ARISING OUT OF,
DIRECTLY OR INDIRECTLY, ANY CLAIM OF PRODUCT LIABILITY, PERSONAL INJURY, OR DEATH ARISING IN ANY
WAY OUT OF SUCH MISSION CRITICAL APPLICATION, WHETHER OR NOT INTEL OR ITS SUBCONTRACTOR WAS
NEGLIGENT IN THE DESIGN, MANUFACTURE, OR WARNING OF THE INTEL PRODUCT OR ANY OF ITS PARTS.
Designers must not rely on the absence or characteristics of any features or instructions marked "reserved" or
"undefined." Intel reserves these for future definition and shall have no responsibility whatsoever for conflicts or
incompatibilities arising from future changes to them.
The product may contain design defects or errors known as errata which may cause the product to deviate from
published specifications. Current characterized errata are available on request.
This document and the software described in it are furnished under license and may only be used or copied in
accordance with the terms of the license. The information in this manual is furnished for informational use only, is
subject to change without notice, and should not be construed as a commitment by Intel Corporation. Intel
Corporation assumes no responsibility or liability for any errors or inaccuracies that may appear in this document
or any software that may be provided in association with this document.
Except as permitted by such license, no part of this document may be reproduced, stored in a retrieval system, or
transmitted in any form or by any means without the express written consent of Intel Corporation.
Copies of documents which have an order number and are referenced in this document, or other Intel® Literature,
may be obtained by calling 1-800-548-4725, or go to: http://www.intel.com/design/Literature.htm.
Intel and Xeon are trademarks or registered trademarks of Intel Corporation.
*Other brands and names may be claimed as the property of others.
Copyright © 2016 Intel Corporation. All rights reserved.
Revision 1.34
iii
Table of Contents
Technical Product Specification
Table of Contents
1
2
Introduction ........................................................................................................................................ 1
1.1
Chapter Outline.................................................................................................................................... 1
1.2
Server Board Use Disclaimer .......................................................................................................... 2
Product Features Overview ............................................................................................................. 3
2.1
Components and Features Identification ................................................................................. 6
2.2
Rear Connectors and Back Panel Feature Identification .................................................... 7
2.3
Intel® Light Guided Diagnostic LED .............................................................................................. 8
2.4
Jumper Identification ........................................................................................................................ 8
2.5
Mechanical Dimension and Weight ............................................................................................. 9
2.6
Product Architecture Overview .................................................................................................. 10
2.7
Power Docking Board ..................................................................................................................... 13
2.8
Bridge Board....................................................................................................................................... 14
2.8.1
6G SATA Bridge Board ................................................................................................................... 14
2.8.2
12G SAS Bridge Board with IT mode ....................................................................................... 15
2.8.3
12G SAS Bridge Board with RAID 0, 1 and 10 ...................................................................... 15
2.8.4
12G SAS Bridge Board with RAID 0, 1, 5 and 10 ................................................................. 16
2.9
3
iv
Riser Card ............................................................................................................................................ 16
2.9.1
Riser Slot 1 Riser Card .................................................................................................................... 16
2.9.2
Riser Slot 2 Riser Card .................................................................................................................... 16
2.10
I/O Module Carrier ........................................................................................................................... 17
2.11
Compute Module Fans ................................................................................................................... 17
2.12
Air Duct ................................................................................................................................................. 18
2.13
Intel® RAID C600 Upgrade Key .................................................................................................... 18
2.14
Intel® Remote Management Module 4 (Intel® RMM4) Lite................................................ 19
2.15
Breakout Board ................................................................................................................................. 19
2.16
System Software Overview .......................................................................................................... 21
2.16.1
System BIOS ....................................................................................................................................... 22
2.16.2
Field Replaceable Unit (FRU) and Sensor Data Record (SDR) Data ............................. 26
2.16.3
Baseboard Management Controller (BMC) Firmware ....................................................... 27
Processor Support.......................................................................................................................... 28
3.1
Processor Socket Assembly ........................................................................................................ 28
3.2
Processor Thermal Design Power (TDP) Support .............................................................. 29
3.3
Processor Population Rules ......................................................................................................... 29
3.4
Processor Initialization Error Summary .................................................................................. 30
3.5
Processor Function Overview ..................................................................................................... 33
Revision 1.34
Technical Product Specification
3.5.1
Processor Core Features ............................................................................................................... 33
3.5.2
Supported Technologies .............................................................................................................. 33
3.6
4
Memory Subsystem Architecture .............................................................................................. 37
4.1.1
IMC Modes of Operation ............................................................................................................... 38
4.1.2
Memory RASM Features ................................................................................................................ 39
4.2
Supported Memory ......................................................................................................................... 40
4.3
Memory Slot Identification and Population Rules ............................................................. 40
4.4
System Memory Sizing and Publishing................................................................................... 42
4.4.1
Effects of Memory Configuration on Memory Sizing ........................................................ 42
4.4.2
Publishing System Memory ......................................................................................................... 43
4.5
Memory Initialization ...................................................................................................................... 44
Server Board I/O ............................................................................................................................. 47
5.1
PCI Express* Support...................................................................................................................... 47
5.1.1
PCIe Enumeration and Allocation ............................................................................................. 47
5.1.2
PCIe Non-Transparent Bridge (NTB) ........................................................................................ 48
5.2
5.2.1
5.3
5.3.1
5.4
Add-in Card Support ...................................................................................................................... 49
Riser Card Support .......................................................................................................................... 49
Serial ATA (SATA) Support ........................................................................................................... 51
Staggered Disk Spin-Up ................................................................................................................ 53
Embedded SATA RAID Support ................................................................................................. 53
5.4.1
Intel® Rapid Storage Technology (RSTe) 4.0 ......................................................................... 53
5.4.2
Intel® Embedded Server RAID Technology 2 (ESRT2)....................................................... 54
5.5
6
Processor Heat Sink ........................................................................................................................ 36
Memory Support ............................................................................................................................. 37
4.1
5
Table of Contents
Network Interface............................................................................................................................. 56
5.5.1
MAC Address Definition ................................................................................................................ 57
5.5.2
LAN Manageability ........................................................................................................................... 57
5.6
Video Support ................................................................................................................................... 57
5.7
Universal Serial Bus (USB) Ports ................................................................................................ 58
5.8
Serial Port ............................................................................................................................................ 59
5.9
InfiniBand* Adapter ......................................................................................................................... 59
5.9.1
Device Interfaces .............................................................................................................................. 60
5.9.2
Quad Small Form-factor Pluggable (QSFP+) Connector ................................................. 61
Connector and Header .................................................................................................................. 62
6.1
Power Connectors ........................................................................................................................... 62
6.1.1
Main Power Connector .................................................................................................................. 62
6.1.2
Backup Power Connector ............................................................................................................. 62
Revision 1.34
v
Table of Contents
6.2
System Management Headers .................................................................................................... 63
6.2.1
Intel® Remote Management Module 4 (Intel® RMM4) Lite Connector.......................... 63
6.2.2
IPMB Header....................................................................................................................................... 63
6.2.3
Control Panel Connector .............................................................................................................. 63
6.3
Bridge Board Connector ................................................................................................................ 64
6.3.1
6.4
6.4.1
PCI Express* Connectors............................................................................................................... 66
6.4.2
VGA Connector.................................................................................................................................. 74
6.4.3
NIC Connectors ................................................................................................................................. 75
6.4.4
SATA Connectors ............................................................................................................................. 75
6.4.5
SATA SGPIO Connectors............................................................................................................... 76
6.4.6
Hard Drive Activity LED Header.................................................................................................. 76
6.4.7
Intel® RAID C600 Upgrade Key Connector ............................................................................. 76
6.4.8
Serial Port Connectors ................................................................................................................... 77
6.4.9
USB Connectors ................................................................................................................................ 77
6.4.10
QSFP+ for InfiniBand* .................................................................................................................... 78
6.4.11
UART Header...................................................................................................................................... 78
Fan Headers........................................................................................................................................ 79
6.5.1
FAN Control Cable Connector .................................................................................................... 79
6.5.2
Discrete System FAN Connector................................................................................................ 79
6.6
Power Docking Board Connectors ............................................................................................ 80
6.7
Breakout Board Connector .......................................................................................................... 81
Configuration Jumpers ................................................................................................................. 82
7.1
PS All Node off (J6B4) .................................................................................................................... 83
7.2
BMC Force Update (J6B6)............................................................................................................. 83
7.3
ME Force Update (J5D2) ................................................................................................................ 84
7.4
Password Clear (J6B8) ................................................................................................................... 85
7.5
BIOS Recovery Mode (J6B9) ........................................................................................................ 86
7.6
8
Power Button ..................................................................................................................................... 65
I/O Connectors .................................................................................................................................. 66
6.5
7
Technical Product Specification
BIOS Default (J6B7)......................................................................................................................... 88
Intel Light-Guided Diagnostics................................................................................................... 90
®
8.1
Status LED ........................................................................................................................................... 90
8.2
ID LED .................................................................................................................................................... 93
8.3
BMC Boot/Reset Status LED Indicators .................................................................................. 93
8.4
InfiniBand* Link/Activity LED ...................................................................................................... 94
8.5
POST Code Diagnostic LEDs ....................................................................................................... 94
9
Platform Management ................................................................................................................... 96
vi
Revision 1.34
Technical Product Specification
9.1
Table of Contents
Management Feature Set Overview ......................................................................................... 96
9.1.1
IPMI 2.0 Features Overview ......................................................................................................... 96
9.1.2
Non IPMI Features Overview ....................................................................................................... 97
9.2
Platform Management Features and Functions .................................................................. 99
9.2.1
Power Subsystem ............................................................................................................................ 99
9.2.2
Advanced Configuration and Power Interface (ACPI) ....................................................... 99
9.2.3
System Initialization ..................................................................................................................... 100
9.2.4
System Event Log (SEL) .............................................................................................................. 101
9.3
Sensor Monitoring ........................................................................................................................ 101
9.3.1
Sensor Scanning ............................................................................................................................ 101
9.3.2
Sensor Rearm Behavior .............................................................................................................. 101
9.3.3
BIOS Event-Only Sensors .......................................................................................................... 102
9.3.4
Margin Sensors............................................................................................................................... 103
9.3.5
IPMI Watchdog Sensor ............................................................................................................... 103
9.3.6
BMC Watchdog Sensor ............................................................................................................... 103
9.3.7
BMC System Management Health Monitoring .................................................................. 103
9.3.8
VR Watchdog Timer ..................................................................................................................... 103
9.3.9
System Airflow Monitoring........................................................................................................ 103
9.3.10
Thermal Monitoring ..................................................................................................................... 104
9.3.11
Processor Sensors ........................................................................................................................ 107
9.3.12
Voltage Monitoring ....................................................................................................................... 110
9.3.13
Fan Monitoring ............................................................................................................................... 110
9.3.14
Standard Fan Management....................................................................................................... 112
9.3.15
Power Management Bus (PMBus*)......................................................................................... 118
9.3.16
Power Supply Dynamic Redundancy Sensor .................................................................... 119
9.3.17
Component Fault LED Control ................................................................................................ 119
9.3.18
CMOS Battery Monitoring .......................................................................................................... 120
9.4
Intel® Intelligent Power Node Manager (NM)...................................................................... 120
9.4.1
Hardware Requirements ............................................................................................................ 120
9.4.2
Features............................................................................................................................................. 121
9.4.3
ME System Management Bus (SMBus*) Interface............................................................ 121
9.4.4
PECI 3.0 ............................................................................................................................................. 121
9.4.5
NM “Discovery” OEM SDR .......................................................................................................... 121
9.4.6
SmaRT/CLST ................................................................................................................................... 122
9.5
Basic and Advanced Server Management Features ....................................................... 122
9.5.1
Dedicated Management Port ................................................................................................... 123
9.5.2
Embedded Web Server............................................................................................................... 123
Revision 1.34
vii
Table of Contents
9.5.3
Technical Product Specification
Advanced Management Feature Support (RMM4 Lite) ................................................. 125
10 Thermal Management ................................................................................................................. 130
11 System Security ............................................................................................................................ 132
11.1
Password Setup ............................................................................................................................. 132
11.1.1
System Administrator Password Rights .............................................................................. 133
11.1.2
Authorized System User Password Rights and Restrictions ....................................... 133
11.2
Front Panel Lockout ..................................................................................................................... 134
11.3
Trusted Platform Module (TPM) support ............................................................................ 134
11.3.1
TPM security BIOS ........................................................................................................................ 135
11.3.2
Physical presence ......................................................................................................................... 135
11.3.3
TPM security setup options ...................................................................................................... 135
12 Environmental Limits Specification ......................................................................................... 137
13 Power Supply Specification Guidelines .................................................................................. 138
13.1
Power Supply DC Output Connector .................................................................................... 138
13.2
Power Supply DC Output Specification ............................................................................... 138
13.2.1
Output Power/Currents .............................................................................................................. 138
13.2.2
Standby Output ............................................................................................................................. 139
13.2.3
Voltage Regulation ....................................................................................................................... 139
13.2.4
Dynamic Loading ........................................................................................................................... 139
13.2.5
Capacitive Loading ....................................................................................................................... 139
13.2.6
Grounding......................................................................................................................................... 140
13.2.7
Closed-loop Stability ................................................................................................................... 140
13.2.8
Residual Voltage Immunity in Standby Mode ................................................................... 140
13.2.9
Common Mode Noise .................................................................................................................. 140
13.2.10 Soft Starting .................................................................................................................................... 140
13.2.11 Zero Load Stability Requirements ......................................................................................... 141
13.2.12 Hot Swap Requirements............................................................................................................. 141
13.2.13 Forced Load Sharing .................................................................................................................... 141
13.2.14 Ripple/Noise .................................................................................................................................... 141
13.2.15 Timing Requirement .................................................................................................................... 141
Appendix A: Integration and Usage Tips ........................................................................................ 145
Appendix B: Integrated BMC Sensor Tables .................................................................................. 146
Appendix C: BIOS Sensors and SEL Data........................................................................................ 163
Appendix D: POST Code Diagnostic LED Decoder ....................................................................... 170
Appendix E: POST Code Errors ......................................................................................................... 177
POST Error Beep Codes .................................................................................................................................... 179
Appendix F: Statement of Volatility ................................................................................................ 181
viii
Revision 1.34
Technical Product Specification
Table of Contents
Glossary ................................................................................................................................................. 183
Reference Documents......................................................................................................................... 185
Revision 1.34
ix
List of Figures
Technical Product Specification
List of Figures
Figure 1. Intel® Server Board S2600KPFR (demo picture) ............................................................................. 3
Figure 2. Intel® Compute Module HNS2600KPR (demo picture) ................................................................ 3
Figure 3. Server Board Components (S2600KPFR).......................................................................................... 6
Figure 4. Compute Module Components ............................................................................................................. 6
Figure 5. Server Board Rear Connectors .............................................................................................................. 7
Figure 6. Compute Module Back Panel ................................................................................................................. 7
Figure 7. Intel® Light Guided Diagnostic LED ...................................................................................................... 8
Figure 8. Jumper Identification ................................................................................................................................ 8
Figure 9. Server Board Dimension .......................................................................................................................... 9
Figure 10. Compute Module Dimension ............................................................................................................... 9
Figure 11. Intel® Server Board S2600KPR Block Diagram .......................................................................... 11
Figure 12. Intel® Server Board S2600KPFR Block Diagram........................................................................ 12
Figure 13. Intel® Server Board S2600KPTR Block Diagram ......................................................................... 13
Figure 14. Power Docking Board Overview ...................................................................................................... 14
Figure 15. 6G SATA Bridge Board Overview .................................................................................................... 15
Figure 16. 12G SAS Bridge Board with IT mode Overview ........................................................................ 15
Figure 17. 12G SAS Bridge Board with RAID 0, 1 and 10 Overview ....................................................... 15
Figure 18. 12G SAS Bridge Board with RAID 0, 1, 5 and 10 Overview .................................................. 16
Figure 19. Riser Card for Riser Slot #1 ............................................................................................................... 16
Figure 20. Riser Card for Riser Slot #2 ............................................................................................................... 17
Figure 21. I/O Module Carrier ................................................................................................................................ 17
Figure 22. Compute Module Fans ........................................................................................................................ 17
Figure 23. Air Duct ...................................................................................................................................................... 18
Figure 24. Intel® RAID C600 Upgrade Key ......................................................................................................... 19
Figure 25. Intel® RMM4 Lite ..................................................................................................................................... 19
Figure 26. Breakout Board Front and Rear View ............................................................................................ 20
Figure 27. Breakout Board Mechanical Drawing (Unit: mm)...................................................................... 21
Figure 28. Processor Socket Assembly .............................................................................................................. 28
Figure 29. Processor Socket ILM .......................................................................................................................... 28
Figure 30. Processor Heat Sink Overview ......................................................................................................... 36
Figure 31. Integrated Memory Controller Functional Block Diagram ................................................... 37
Figure 32. DIMM Slot Identification ..................................................................................................................... 41
Figure 33. Add-in Card Support Block Diagram (S2600KPR) ................................................................... 49
Figure 34. Server Board Riser Slots (S2600KPFR) ......................................................................................... 49
Figure 35. SATA Support ......................................................................................................................................... 51
x
Revision 1.34
Technical Product Specification
List of Figures
Figure 36. SATA RAID 5 Upgrade Key................................................................................................................. 55
Figure 37. Network Interface Connectors ......................................................................................................... 56
Figure 38. RJ45 NIC Port LED................................................................................................................................. 57
Figure 39. USB Ports Block Diagram ................................................................................................................... 59
Figure 40. Serial Port A Location .......................................................................................................................... 59
Figure 41. Jumper Location .................................................................................................................................... 82
Figure 42. Status LED (E) and ID LED (D) ........................................................................................................... 90
Figure 43. InfiniBand* Link LED (K) and InfiniBand* Activity LED (J) ..................................................... 94
Figure 44. Rear Panel Diagnostic LEDs .............................................................................................................. 95
Figure 45. High-level Fan Speed Control Process...................................................................................... 115
Figure 46. Air Flow and Fan Identification ..................................................................................................... 130
Figure 47. Turn On/Off Timing (Power Supply Signals – 5VSB) ........................................................... 144
Figure 48. Turn On/Off Timing (Power Supply Signals – 12VSB) ........................................................... 144
Figure 49. Diagnostic LED Placement Diagram ........................................................................................... 170
Revision 1.34
xi
List of Tables
Technical Product Specification
List of Tables
Table 1. Intel® Server Board S2600KP Product Family Feature Set .......................................................... 4
Table 2. Intel® Compute Module HNS2600KP Product Family Feature Set .......................................... 5
Table 3. Product Weight and Packaging ........................................................................................................... 10
Table 4. POST Hot-Keys ........................................................................................................................................... 24
Table 5. Mixed Processor Configurations Error Summary......................................................................... 31
Table 6. DDR4 DIMM Support Guidelines ......................................................................................................... 40
Table 7. DIMM Nomenclature ................................................................................................................................ 41
Table 8. Supported DIMM Populations.............................................................................................................. 41
Table 9. PCIe* Port Routing – CPU 1 ................................................................................................................... 50
Table 10. PCIe* Port Routing – CPU 2 ................................................................................................................ 50
Table 11. SATA and sSATA Controller BIOS Utility Setup Options ....................................................... 51
Table 12. SATA and sSATA Controller Feature Support ............................................................................ 52
Table 13. Onboard Video Resolution and Refresh Rate (Hz) .................................................................... 58
Table 14. Network Port Configuration ............................................................................................................... 60
Table 15. Main Power Supply Connector 6-pin 2x3 Connector.............................................................. 62
Table 16. Backup Power Connector .................................................................................................................... 62
Table 17. Intel® RMM4 Lite Connector ................................................................................................................ 63
Table 18. IPMB Header ............................................................................................................................................. 63
Table 19. Control Panel Connector ..................................................................................................................... 63
Table 20. Bridge Board Connector ...................................................................................................................... 64
Table 21. SATA DOM Connector Pin-out .......................................................................................................... 65
Table 22. USB 2.0 Type-A Connector Pin-out ................................................................................................ 66
Table 23. 5V_AUX Power Connector Pin-out.................................................................................................. 66
Table 24. CPU1 and CPU2 PCIe Bus Connectivity......................................................................................... 66
Table 25. PCI Express* x16 Riser Slot 1 Connector ...................................................................................... 67
Table 26. PCI Express* x24 Riser Slot 2 Connector ...................................................................................... 69
Table 27. PCI Express* x24 Riser Slot 3 Connector ...................................................................................... 72
Table 28. PCI Express* Riser ID Assignment .................................................................................................... 74
Table 29. PCI Express* Clock Source by Slot .................................................................................................. 74
Table 30. VGA External Video Connector ......................................................................................................... 74
Table 31. RJ-45 10/100/1000 NIC Connector ............................................................................................... 75
Table 32. SATA Connector ...................................................................................................................................... 76
Table 33. SATA SGPIO Connector ....................................................................................................................... 76
Table 34. SATA HDD Activity LED Header ........................................................................................................ 76
Table 35. Storage Upgrade Key Connector ..................................................................................................... 77
xii
Revision 1.34
Technical Product Specification
List of Tables
Table 36. Internal 9-pin Serial A ........................................................................................................................... 77
Table 37. External USB port Connector............................................................................................................. 77
Table 38. Internal USB Connector ....................................................................................................................... 77
Table 39. QSFP+ Connector ................................................................................................................................... 78
Table 40. UART Header ............................................................................................................................................ 78
Table 41. Baseboard Fan Connector................................................................................................................... 79
Table 42. Baseboard Fan Connector................................................................................................................... 79
Table 43. Main Power Input Connector ............................................................................................................. 80
Table 44. Fan Control Signal Connector ........................................................................................................... 80
Table 45. Compute Module Fan Connector ..................................................................................................... 80
Table 46. Main Power Output Connector ......................................................................................................... 80
Table 47. Miscellaneous Signal Connector ...................................................................................................... 81
Table 48. Jumper Modes Selection ..................................................................................................................... 82
Table 49. PS All Node off (J6B4) .......................................................................................................................... 83
Table 50. Force Integrated BMC Update Jumper (J6B6)............................................................................ 83
Table 51. Force ME Update Jumper (J5D2) ..................................................................................................... 84
Table 52. Password Clear Jumper (J6B8) ......................................................................................................... 86
Table 53. BIOS Recovery Mode Jumper (J6B9) ............................................................................................. 87
Table 54. BIOS Default Jumper............................................................................................................................. 88
Table 55. Status LED State Definitions .............................................................................................................. 91
Table 56. ID LED .......................................................................................................................................................... 93
Table 57. BMC Boot/Reset Status LED Indicators ......................................................................................... 93
Table 58. InfiniBand* Link/Activity LED ............................................................................................................. 94
Table 59. ACPI Power States .................................................................................................................................. 99
Table 60. Processor Sensors ............................................................................................................................... 107
Table 61. Processor Status Sensor Implementation ................................................................................. 108
Table 62. Component Fault LEDs...................................................................................................................... 120
Table 63. Intel® Remote Management Module 4 (RMM4) Options ...................................................... 123
Table 64. Basic and Advanced Server Management Features Overview .......................................... 123
Table 65. Air Flow .................................................................................................................................................... 130
Table 66. TPM Setup Utility – Security Configuration Screen Fields ................................................. 136
Table 67. Server Board Design Specifications ............................................................................................. 137
Table 68. Power Supply DC Power Input Connector Pin-out................................................................ 138
Table 69. Minimum 1200W/1600W Load Ratings..................................................................................... 138
Table 70. Minimum 2130W Load Ratings...................................................................................................... 138
Table 71. Voltage Regulation Limits ................................................................................................................ 139
Table 72. Transient Load Requirements ........................................................................................................ 139
Revision 1.34
xiii
List of Tables
Technical Product Specification
Table 73. Capacitive Loading Conditions....................................................................................................... 140
Table 74. Ripples and Noise ................................................................................................................................ 141
Table 75. Timing Requirements ......................................................................................................................... 142
Table 76. Timing Requirements (12VSB) ....................................................................................................... 143
Table 77. BMC Sensor Table ............................................................................................................................... 148
Table 78. BIOS Sensor and SEL Data ............................................................................................................... 163
Table 79. POST Code LED Example ................................................................................................................. 171
Table 80. MRC Fatal Error Codes ....................................................................................................................... 171
Table 81. MRC Progress Codes .......................................................................................................................... 172
Table 82. POST Progress Codes ........................................................................................................................ 173
Table 83. POST Error Codes and Messages.................................................................................................. 177
Table 84. POST Error Beep Codes .................................................................................................................... 179
Table 85. Glossary ................................................................................................................................................... 183
xiv
Revision 1.34
Technical Product Specification
List of Tables
<This page is intentionally left blank.>
Revision 1.34
xv
Technical Product Specification
1
Introduction
Introduction
This Technical Product Specification (TPS) provides specific information detailing the features,
functionality, and high-level architecture of the Intel® Server Board S2600KP product family
and the Intel® Compute Module HNS2600KP product family.
Design-level information related to specific server board components and subsystems can be
obtained by ordering External Product Specifications (EPS) or External Design Specifications
(EDS) related to this server generation. EPS and EDS documents are made available under
NDA with Intel and must be ordered through your local Intel representative. See the Reference
Documents section for a list of available documents.
1.1
Chapter Outline
This document is divided into the following chapters:

Chapter 1 – Introduction

Chapter 2 – Product Features Overview

Chapter 3 – Processor Support

Chapter 4 – Memory Support

Chapter 5 – Server Board I/O

Chapter 6 – Connector and Header

Chapter 7 – Configuration Jumpers

Chapter 8 – Intel® Light-Guided Diagnostics

Chapter 9 – Platform Management

Chapter 10 – Thermal Management

Chapter 11 – System Security

Chapter 12 – Environmental Limits Specification

Chapter 13 – Power Supply Specification Guidelines

Appendix A – Integration and Usage Tips

Appendix B – Integrated BMC Sensor Tables

Appendix C – BIOS Sensors and SEL Data

Appendix D – POST Code Diagnostic LED Decoder

Appendix E – POST Code Errors

Appendix F – Statement of Volatility

Glossary

Reference Documents
Revision 1.34
1
Introduction
Technical Product Specification
1.2 Server Board Use Disclaimer
Intel Corporation server boards contain a number of high-density VLSI (Very Large Scale
Integration) and power delivery components that need adequate airflow to cool. Intel ensures
through its own chassis development and testing that when Intel server building blocks are
used together, the fully integrated system will meet the intended thermal requirements of
these components. It is the responsibility of the system integrator who chooses not to use
Intel developed server building blocks to consult vendor datasheets and operating
parameters to determine the amount of air flow required for their specific application and
environmental conditions. Intel Corporation cannot be held responsible if components fail or
the server board does not operate correctly when used outside any of their published
operating or non-operating limits.
2
Revision 1.34
Technical Product Specification
2
Product Features Overview
Product Features Overview
The Intel® Server Board S2600KP product family is a monolithic printed circuit board (PCB)
assembly with features designed to support the high performance and high density
computing markets. This server board is designed to support the Intel® Xeon® processor E52600 v3/v4 product family. Previous generation Intel® Xeon® processors are not supported.
The Intel® Server Board S2600KP product family contains two server board options. Many of
the features and functions of the server board family are common. A board will be identified
by its name which has described features or functions unique to it.

S2600KPFR – With onboard InfiniBand* controller providing one external rear QSFP+
port
Figure 1. Intel® Server Board S2600KPFR (demo picture)

S2600KPR – Without onboard InfiniBand* controller, no external rear QSFP+ port
The Intel® Compute Module HNS2600KP product family provides two compute module
options, each integrated with either of the server board from the Intel® Server Board S2600KP
product family.
Figure 2. Intel® Compute Module HNS2600KPR (demo picture)
Revision 1.34
3
Product Features Overview
Technical Product Specification
The following table provides a high-level product feature list.
Table 1. Intel® Server Board S2600KP Product Family Feature Set
Feature
Processor Support


Memory Support
Chipset
External I/O Connections
Internal I/O
connectors/headers
PCIe Support
Power Connections
System Fan Support
Video
Riser Support
4
Description
Two LGA2011-3 (Socket R3) processor sockets
Support for one or two Intel® Xeon® processors E5-2600 v3/v4
product family
 Maximum supported Thermal Design Power (TDP) of up to 160 W
 Eight DIMM slots in total across eight memory channels
 Registered DDR4 (RDIMM), Load Reduced DDR4 (LRDIMM)
 Memory DDR4 data transfer rates of 1600/1866/2133/2400 MT/s
Intel® C612 chipset
 DB-15 video connector
 Two RJ-45 1GbE Network Interface Controller (NIC) ports
 One dedicated RJ-45 port for remote server management
 One stacked two port USB 2.0 (port 0/1) connector
 One InfiniBand* FDR QSFP+ port (S2600KPFR only)
 Bridge slot to extend board I/O
o Four SATA 6Gb/s signals to backplane
o Front control panel signals
o One SATA 6Gb/s port for SATA DOM
o One USB 2.0 connector (port 10)
 One internal USB 2.0 connector (port 6/7)
 One 2x7 pin header for system fan module
 One 1x12 pin control panel header
 One DH-10 serial Port A connector
 One SATA 6Gb/s port for SATA DOM
 Four SATA 6Gb/s connectors (port 0/1/2/3)
 One 2x4 pin header for Intel® RMM4 Lite
 One 1x4 pin header for Storage Upgrade Key
 One 1x8 pin backup power connector
PCIe* 3.0 (2.5, 5, 8 GT/s)
Two sets of 2x3 pin connectors (main power 1/2)
 One 2x7 pin fan control connector for Intel compute module and
chassis
 Three 1x8 pin fan connectors for third-party chassis
 Integrated 2D video graphics controller
 16MB DDR3 memory
 Three riser slots
o Riser slot 1 provides x16 PCIe* 3.0 lanes
o Riser slot 2 provides
 x24 PCIe* 3.0 lanes for S2600KPR
 x16 PCIe* 3.0 lanes for S2600KPFR
o Riser slot 3 provides x24 PCIe* 3.0 lanes
 One bridge board slot for board I/O expansion
Revision 1.34
Technical Product Specification
Feature
On-board storage
controllers and options
RAID Support
Server Management
Security
Product Features Overview
Description
5 on-board SATA 6Gb/s ports, one of them is SATA DOM compatible.
5 SATA 6Gb/s signals to backplane via bridge slot.
 Intel® Rapid Storage RAID Technology (RSTe) 4.0
 Intel® Embedded Server RAID Technology 2 (ESRT2) with optional
Intel® RAID C600 Upgrade Key to enable SATA RAID 5
 Onboard Emulex* Pilot III* Controller
 Support for Intel® Remote Management Module 4 Lite solutions
 Intel® Light-Guided Diagnostics on field replaceable units
 Support for Intel® System Management Software
 Support for Intel® Intelligent Power Node Manager (Need
PMBus*-compliant power supply)
 Intel® Trusted Platform Module (TPM) v1.2 for BBS2600KPTR only
Warning! The riser slot 1 on the server board is designed for plugging in ONLY the riser card.
Plugging in any PCIe* card may cause permanent server board and PCIe* card damage.
Table 2. Intel® Compute Module HNS2600KP Product Family Feature Set
Feature1
Server Board
Processor Support
Heat Sink
Fan
Riser Support
Compute Module Board
Air Duct
Description
Intel Server Board S2600KP product family
 HNS2600KPR – include Intel® Server Board S2600KPR
 HNS2600KPFR – include Intel® Server Board S2600KPFR
Maximum supported Thermal Design Power (TDP) of up to 145 W
 One Cu/Al 91.5x91.5mm heat sink for CPU 1
 One Ex-Al 91.5x91.5mm heat sink for CPU 2
Three sets of 40x56mm dual rotor system fans
 One riser card with bracket on riser slot 1 to support one PCIe* 3.0
x16 low profile card (default)2
 One I/O module riser and carrier kit on riser slot 2 to support an
Intel® I/O Expansion Module (optional)
Note: Riser slot 3 cannot be used with the bridge board installed.
 Three types of bridge boards:
o 6G SATA Bridge Board (Default)
o 12G SAS Bridge Board (Optional)
o 12G SAS Bridge Board with RAID 5 (Optional)
 One compute module power docking board
One transparent air duct
®
Notes:
1. The table only lists features that are unique to the compute module or different from the
server board.
Revision 1.34
5
Product Features Overview
Technical Product Specification
2. ONLY low profile PCIe* card can be installed on riser slot 1 riser card of the compute
module.
2.1 Components and Features Identification
This section provides a general overview of the server board and compute module, identifying
key features and component locations. The majority of the items identified are common in the
product family.
Figure 3. Server Board Components (S2600KPFR)
Figure 4. Compute Module Components
6
Revision 1.34
Technical Product Specification
Product Features Overview
2.2 Rear Connectors and Back Panel Feature Identification
The Intel® Server Board S2600KP product family has the following board rear connector
placement.
A
Description
NIC port 1 (RJ45)
G
Description
Dedicated Management Port (RJ45)
B
NIC port 2 (RJ45)
H
InfiniBand* Port (QSFP+, S2600KPFR only)
C
Video out (DB-15)
I
POST Code LEDs (8 LEDs)
D
ID LED
J
InfiniBand* Activity LED (S2600KPFR only)
E
Status LED
K
InfiniBand* Link LED (S2600KPFR only)
F
Dual port USB
Figure 5. Server Board Rear Connectors
The Intel® Compute Module HNS2600KP product family has the following back panel features.
Figure 6. Compute Module Back Panel
Revision 1.34
7
Product Features Overview
Technical Product Specification
2.3 Intel® Light Guided Diagnostic LED
Figure 7. Intel® Light Guided Diagnostic LED
2.4 Jumper Identification
Figure 8. Jumper Identification
8
Revision 1.34
Technical Product Specification
Product Features Overview
2.5 Mechanical Dimension and Weight
Figure 9. Server Board Dimension
Figure 10. Compute Module Dimension
Revision 1.34
9
Product Features Overview
Technical Product Specification
Approximate product weight is listed in the following table for reference. Variations are
expected with real shipping products.
Table 3. Product Weight and Packaging
Product Code
BBS2600KPR
Quantity per Box
10
Box Dimension (mm)
553X242X463
Net Weight
10.0 kg
Package Weight
12.8 kg
BBS2600KPFR
10
553X242X463
10.4 kg
13.2 kg
BBS2600KPTR
10
553X242X463
0.98 kg
12.6 kg
HNS2600KPR
1
716X269X158
3.4 kg
4.6 kg
HNS2600KPFR
1
716X269X158
3.44 kg
4.64 kg
2.6 Product Architecture Overview
The Intel® Server Board S2600KP product family is a purpose built, rack-optimized, liquid
cooling friendly server board used in a high-density rack system. It is designed around the
integrated features and functions of the Intel® Xeon® processor E5-2600 V3/V4 product family,
the Intel® C612 chipset, and other supporting components including the Integrated BMC, the
Intel® I350 network interface controller, and the Mellanox* Connect-IB* adapter (S2600KPFR
only).
The half-width board size allows four boards to reside in a standard multi-compute module
2U Intel® Server Chassis H2000G product family, for high-performance and high-density
computing platforms.
The following diagram provides an overview of the server board architecture, showing the
features and interconnects of each of the major subsystem components.
10
Revision 1.34
Technical Product Specification
Product Features Overview
Figure 11. Intel® Server Board S2600KPR Block Diagram
Revision 1.34
11
Product Features Overview
Technical Product Specification
Figure 12. Intel® Server Board S2600KPFR Block Diagram
12
Revision 1.34
Technical Product Specification
Product Features Overview
Figure 13. Intel® Server Board S2600KPTR Block Diagram
The Intel® Compute Module HNS2600KP product family provides a series of features including
the power docking board, bridge boards, riser cards, fans, and the air duct.
2.7 Power Docking Board
The power docking board provides hot swap docking of 12V main power between the
compute module and the server. It supports three dual rotor fan connections, 12V main power
hot swap controller, and current sensing. The power docking board is intended to support the
usage of the compute module with the Intel® Server Board S2600KP product family.
Label
A
Revision 1.34
Description
2x7-pin fan control connector
13
Product Features Overview
Technical Product Specification
B
8-pin connector for fan 1
C
2x6-pin main power output connector
D
8-pin connector for fan 2
E
12-pin connector for main power input
F
8-pin connector for fan 3
Figure 14. Power Docking Board Overview
2.8 Bridge Board
There are four types of bridge boards that implement different features and functions.

6G SATA bridge board (Default)

12G SAS bridge board with IT mode (Optional)

12G SAS bridge board with RAID 0, 1 and 10 (Optional)

12G SAS bridge board with RAID 0, 1, 5 and 10 (Optional)
Note: All 12G SAS bridge boards require two processors installed to be functional.
2.8.1 6G SATA Bridge Board
The 6G SATA bridge board provides hot swap interconnect of all electrical signals to the
backplane of the server chassis (except for main 12V power). It supports up to 4x lanes of
SATA, a 7-pin SATA connector for SATA DOM devices, and a type-A USB connector for USB
flash device. One bridge board is used per one compute module. The bridge board is secured
with screws to the compute module.
Label
14
Description
A
2x40-pin card edge connector (to the backplane)
B
USB 2.0 Type-A connector
C
2-pin 5V power
D
SATA DOM port connector
E
2x40-pin card edge connector (to the bridge board
connector on the server board)
Revision 1.34
Technical Product Specification
Product Features Overview
Figure 15. 6G SATA Bridge Board Overview
2.8.2 12G SAS Bridge Board with IT mode
The optional 12G SAS bridge board with IT mode has one embedded LSI* SAS 3008 controller
to support up to four SAS/SATA, a 7-pin SATA connector for SATA DOM devices, and a UART
(Universal Asynchronous Receiver/Transmitter) header. One bridge board is used per one
compute module, connecting to the bridge board slot and Riser Slot 3.
A
Label
Description
2x40-pin card edge connector (to the backplane)
B
UART header
C
2-pin 5V power
D
SATA DOM port connector
E
2x40-pin card edge connector (to the bridge board
connector on the server board)
F
200-pin connector (to Riser Slot 3 on the server board)
Figure 16. 12G SAS Bridge Board with IT mode Overview
2.8.3 12G SAS Bridge Board with RAID 0, 1 and 10
The optional 12G SAS bridge board has one embedded LSI* SAS 3008 controller to support
up to four SAS/SATA ports with RAID 0, 1, and 10 support, a 7-pin SATA connector for SATA
DOM devices, and a type-A USB connector for USB flash device. One bridge board is used per
one compute module, connecting to the bridge board slot and Riser Slot 3.
A
Label
Description
2x40-pin card edge connector (to the backplane)
B
UART header
C
2-pin 5V power
D
SATA DOM port connector
E
2x40-pin card edge connector (to the bridge board
connector on the server board)
F
200-pin connector (to Riser Slot 3 on the server board)
Figure 17. 12G SAS Bridge Board with RAID 0, 1 and 10 Overview
Revision 1.34
15
Product Features Overview
Technical Product Specification
2.8.4 12G SAS Bridge Board with RAID 0, 1, 5 and 10
The optional 12G SAS bridge board with RAID 5 has one embedded LSI* SAS 3008 controller
to support up to four SAS/SATA ports with RAID 0, 1, 10, and RAID 5 support, a 7-pin SATA
connector for SATA DOM devices, and a UART (Universal Asynchronous Receiver/Transmitter)
header. One bridge board is used per one compute module, connecting to the bridge board
slot and Riser Slot 3.
A
Label
Description
2x40-pin card edge connector (to the backplane)
B
UART header
C
2-pin 5V power
D
SATA DOM port connector
E
2x40-pin card edge connector (to the bridge board
connector on the server board)
F
200-pin connector (to Riser Slot 3 on the server board)
Figure 18. 12G SAS Bridge Board with RAID 0, 1, 5 and 10 Overview
2.9 Riser Card
There are two types of riser cards:

Riser slot 1 riser card (for Riser slot 1 only)

Riser slot 2 riser card (for Riser slot 2 only)
2.9.1 Riser Slot 1 Riser Card
The riser card for riser slot 1 has one PCIe* 3.0 x16 slot.
Figure 19. Riser Card for Riser Slot #1
2.9.2 Riser Slot 2 Riser Card
The riser card for riser slot 2 has one PCIe* 3.0 x16 slot (x8 lanes are for I/O module carrier)
which can only support Intel® I/O Module carrier.
16
Revision 1.34
Technical Product Specification
Product Features Overview
Figure 20. Riser Card for Riser Slot #2
2.10 I/O Module Carrier
To broaden the standard on-board feature set, the server board supports the option of adding
a single I/O module providing external ports for a variety of networking interfaces. The I/O
module attaches to a high density 80-pin connector of the I/O module carrier on the riser slot
2.
Figure 21. I/O Module Carrier
2.11 Compute Module Fans
The cooling subsystem for the compute module consists of three 40 x 40 x 56 dual rotor fans.
These components provide the necessary cooling and airflow.
Figure 22. Compute Module Fans
Revision 1.34
17
Product Features Overview
Technical Product Specification
Note: The Intel® Compute Module HNS2600KP product family does not support redundant
cooling. If one of the compute module fans fails, it is recommended to replace the failed fan as
soon as possible.
Each fan within the compute module can support multiple speeds. Fan speed may change
automatically when any temperature sensor reading changes. The fan speed control algorithm
is programmed into the server board’s BMC.
Each fan connector within the module supplies a tachometer signal that allows the BMC to
monitor the status of each fan. If one of the fans fails, the status LED on the server board will
light up.
The fan control signal is from the BMC on the mother board to the power docking board and
then is distributed to three sets of dual rotor fans. The expected maximum RPM is 25,000.
2.12 Air Duct
Each compute module requires the use of a transparent plastic air duct to direct airflow over
critical areas within the compute module. To maintain the necessary airflow, the air duct must
be properly installed. Before sliding the compute module into the chassis, make sure the air
duct is installed properly.
Figure 23. Air Duct
2.13 Intel® RAID C600 Upgrade Key
The Intel® RAID C600 Upgrade Key RKSATA4R5 is supported. With the optional key installed
on the server board, Intel® ESRT2 SATA RAID 5 is enabled.
18
Revision 1.34
Technical Product Specification
Product Features Overview
Figure 24. Intel® RAID C600 Upgrade Key
2.14 Intel® Remote Management Module 4 (Intel® RMM4) Lite
The optional Intel® RMM4 Lite is a small board that unlocks the advanced management
features when installed on the server board.
Figure 25. Intel® RMM4 Lite
2.15 Breakout Board
Intel provides a breakout board which is designed for the server board only I/O peripherals in
a third-party chassis. It is not a standard accessory of the Intel® Compute Module HNS2600KP
product family or Intel® Server Chassis H2000G product family.
The breakout board provides:

One 7 pin SATA connector for 6Gb/s SATA DOM
Revision 1.34
19
Product Features Overview
Technical Product Specification

One mini-SAS HD SFF-8643 connector for 4x lanes of 6Gb/s SATA

One 7 pin connector for miscellaneous signals:
o
Status LED
o
NMI switch
o
SMBus
o
3.3V auxiliary power (maximum current 50mA)
Label
Description
A
SATA DOM port connector
B
Mini-SAS connector
C
7 pin miscellaneous signals connector
Figure 26. Breakout Board Front and Rear View
The breakout board has reserved holes for users to design their own bracket to fix the board
into the server system. See the following mechanical drawing for details.
20
Revision 1.34
Technical Product Specification
Product Features Overview
Figure 27. Breakout Board Mechanical Drawing (Unit: mm)
2.16 System Software Overview
The server board includes an embedded software stack to enable, configure, and support
various system functions. This software stack includes the System BIOS, Baseboard
Management Controller (BMC) Firmware, Management Engine (ME) Firmware, and
management support data including Field Replaceable Unit (FRU) data and Sensor Data
Record (SDR) data.
The system software is pre-programmed on the server board during factory assembly, making
the server board functional at first power-on after system integration. Typically, as part of the
initial system integration process, FRU and SDR data will have to be installed onto the server
board by the system integrator to ensure the embedded platform management subsystem is
able to provide best performance and cooling for the final system configuration. It is also not
uncommon for the system software stack to be updated to later revisions to ensure the most
reliable system operation. Intel makes periodic system software updates available for
download at the following Intel website: http://downloadcenter.intel.com.
Revision 1.34
21
Product Features Overview
Technical Product Specification
System updates can be performed in a number of operating environments, including the uEFI
Shell using the uEFI-only System Update Package (SUP), or under different operating systems
using the Intel® One Boot Flash Update Utility (OFU).
Reference the following Intel documents for more in-depth information about the system
software stack and their functions:

Intel® Server System BIOS External Product Specification for Intel® Server Systems
supporting the Intel® Xeon® processor E5-2600 v3/v4 product family

Intel® Server System BMC Firmware External Product Specification for Intel® Server
Systems supporting the Intel® Xeon® processor E5-2600 v3/v4 product family
2.16.1
System BIOS
The system BIOS is implemented as firmware that resides in flash memory on the server
board. The BIOS provides hardware-specific initialization algorithms and standard compatible
basic input/output services, and standard Intel® Server Board features. The flash memory also
contains firmware for certain embedded devices.
This BIOS implementation is based on the Extensible Firmware Interface (EFI), according to the
Intel® Platform Innovation Framework for EFI architecture, as embodied in the industry
standards for Unified Extensible Firmware Interface (UEFI).
The implementation is compliant with all Intel® Platform Innovation Framework for EFI
architecture specifications, as further specified in the Unified Extensible Firmware Interface
Reference Specification, Version 2.3.1.
In the UEFI BIOS design, there are three primary components: the BIOS itself, the Human
Interface Infrastructure (HII) that supports communication between the BIOS and external
programs, and the Shell which provides a limited OS-type command-line interface. This BIOS
system implementation complies with HII Version 2.3.1, and includes a Shell.
2.16.1.1 BIOS Revision Identification
The BIOS Identification string is used to uniquely identify the revision of the BIOS being used
on the server. The BIOS ID string is displayed on the Power On Self Test (POST) Diagnostic
Screen and in the <F2> BIOS Setup Main Screen, as well as in System Management BIOS
(SMBIOS) structures.
The BIOS ID string for S2600 series server boards is formatted as follows:
BoardFamilyID.OEMID.MajorVer.MinorVer.RelNum.BuildDateTime
Where:

22
BoardFamilyID = String name to identify board family.
Revision 1.34
Technical Product Specification
o

“SE5C610” is used to identify BIOS builds for Intel® S2600 series Server Boards,
based on the Intel® Xeon® Processor E5-2600 product families and the Intel® C610
chipset family.
OEMID = Three-character OEM BIOS Identifier, to identify the board BIOS “owner”.
o

Product Features Overview
“86B” is used for Intel Commercial BIOS Releases.
MajorVer = Major Version, two decimal digits 01-99 which are changed only to identify
major hardware or functionality changes that affect BIOS compatibility between
boards.
o
“01” is the starting BIOS Major Version for all platforms.

MinorVer = Minor Version, two decimal digits 00-99 which are changed to identify less
significant hardware or functionality changes which do not necessarily cause
incompatibilities but do display differences in behavior or in support of specific
functions for the board.

RelNum = Release Number, four decimal digits which are changed to identify distinct
BIOS Releases. BIOS Releases are collections of fixes and/or changes in functionality,
built together into a BIOS Update to be applied to a Server Board. However, there are
“Full Releases” which may introduce many new fixes/functions, and there are “Point
Releases” which may be built to address very specific fixes to a Full Release.
The Release Numbers for Full Releases increase by 1 for each release. For Point
Releases, the first digit of the Full Release number on which the Point Release is based
is increased by 1. That digit is always 0 (zero) for a Full Release.

BuildDateTime = Build timestamp – date and time in MMDDYYYYHHMM format:
o
MM = Two-digit month.
o
DD = Two-digit day of month.
o
YYYY = Four-digit year.
o
HH = Two-digit hour using 24-hour clock.
o
MM = Two-digit minute.
An example of a valid BIOS ID String is as follows:
SE5C610.86B.01.01.0003.081320110856
The BIOS ID string is displayed on the POST diagnostic screen for BIOS Major Version 01,
Minor Version 01, Full Release 0003 that is generated on August 13, 2011 at 8:56 AM.
The BIOS version in the <F2> BIOS Setup Utility Main Screen is displayed without the
time/date timestamp, which is displayed separately as “Build Date”:
SE5C610.86B.01.01.0003
2.16.1.2 Hot Keys Supported During POST
Certain “Hot Keys” are recognized during POST. A Hot Key is a key or key combination that is
recognized as an unprompted command input, that is, the operator is not prompted to press
Revision 1.34
23
Product Features Overview
Technical Product Specification
the Hot Key and typically the Hot Key will be recognized even while other processing is in
progress.
The BIOS recognizes a number of Hot Keys during POST. After the OS is booted, Hot Keys are
the responsibility of the OS and the OS defines its own set of recognized Hot Keys.
The following table provides a list of available POST Hot Keys along with a description for
each.
Table 4. POST Hot-Keys
<F2>
HotKey Combination
Function
Enter the BIOS Setup Utility
<F6>
Pop-up BIOS Boot Menu
<F12>
Network boot
<Esc>
Switch from Logo Screen to Diagnostic Screen
<Pause>
Stop POST temporarily
2.16.1.3 POST Logo/Diagnostic Screen
The Logo/Diagnostic Screen appears in one of two forms:

If Quiet Boot is enabled in the <F2> BIOS setup, a “splash screen” is displayed with a
logo image, which may be the standard Intel Logo Screen or a customized OEM Logo
Screen. By default, Quiet Boot is enabled in BIOS setup, so the Logo Screen is the
default POST display. However, if the logo is displayed during POST, the user can
press <Esc> to hide the logo and display the Diagnostic Screen instead.

If a customized OEM Logo Screen is present in the designated Flash Memory location,
the OEM Logo Screen will be displayed, overriding the default Intel Logo Screen.

If a logo is not present in the BIOS Flash Memory space, or if Quiet Boot is disabled in
the system configuration, the POST Diagnostic Screen is displayed with a summary of
system configuration information. The POST Diagnostic Screen is purely a Text Mode
screen, as opposed to the Graphics Mode logo screen.

If Console Redirection is enabled in Setup, the Quiet Boot setting is disregarded and
the Text Mode Diagnostic Screen is displayed unconditionally. This is due to the
limitations of Console Redirection, which transfers data in a mode that is not
graphics-compatible.
2.16.1.4 BIOS Boot Pop-Up Menu
The BIOS Boot Specification (BBS) provides a Boot Pop-up menu that can be invoked by
pressing the <F6> key during POST. The BBS Pop-up menu displays all available boot devices.
The boot order in the pop-up menu is not the same as the boot order in the BIOS setup. The
pop-up menu simply lists all of the available devices from which the system can be booted,
and allows a manual selection of the desired boot device.
24
Revision 1.34
Technical Product Specification
Product Features Overview
When an Administrator password is installed in Setup, the Administrator password will be
required in order to access the Boot Pop-up menu using the <F6> key. If a User password is
entered, the Boot Pop-up menu will not even appear – the user will be taken directly to the
Boot Manager in the Setup, where a User password allows only booting in the order previously
defined by the Administrator.
2.16.1.5 Entering BIOS Setup
To enter the BIOS Setup Utility using a keyboard (or emulated keyboard), press the <F2>
function key during boot time when the OEM or Intel Logo Screen or the POST Diagnostic
Screen is displayed.
The following instructional message is displayed on the Diagnostic Screen or under the Quiet
Boot Logo Screen:
Press <F2> to enter setup, <F6> Boot Menu, <F12> Network Boot
Note: With a USB keyboard, it is important to wait until the BIOS “discovers” the keyboard and
beeps – until the USB Controller has been initialized and the USB keyboard activated, key
presses will not be read by the system.
When the Setup Utility is entered, the Main screen is displayed initially. However, in the event
a serious error occurs during POST, the system will enter the BIOS Setup Utility and display
the Error Manager screen instead of the Main screen.
2.16.1.6 BIOS Update Capability
In order to bring BIOS fixes or new features into the system, it will be necessary to replace the
current installed BIOS image with an updated one. The BIOS image can be updated using a
standalone IFLASH32 utility in the uEFI shell, or can be done using the OFU utility program
under a given operating system. Full BIOS update instructions are provided when update
packages are downloaded from the Intel web site.
2.16.1.7 BIOS Recovery
If a system is completely unable to boot successfully to an OS, hangs during POST, or even
hangs and fails to start executing POST, it may be necessary to perform a BIOS Recovery
procedure, which can replace a defective copy of the Primary BIOS.
The BIOS introduces three mechanisms to start the BIOS recovery process, which is called
Recovery Mode:

Recovery Mode Jumper – This jumper causes the BIOS to boot in Recovery Mode.

The Boot Block detects partial BIOS update and automatically boots in Recovery
Mode.

The BMC asserts Recovery Mode GPIO in case of partial BIOS update and FRB2
time-out.
Revision 1.34
25
Product Features Overview
Technical Product Specification
The BIOS Recovery takes place without any external media or Mass Storage device as it
utilizes a Backup BIOS image inside the BIOS flash in Recovery Mode.
The Recovery procedure is included here for general reference. However, if in conflict, the
instructions in the BIOS Release Notes are the definitive version.
When the BIOS Recovery Jumper (see Figure 38) is set, the BIOS begins by logging a “Recovery
Start” event to the System Event Log (SEL). It then loads and boots with a Backup BIOS image
residing in the BIOS flash device. This process takes place before any video or console is
available. The system boots to the embedded uEFI shell, and a “Recovery Complete” event is
logged to the SEL. From the uEFI Shell, the BIOS can then be updated using a standard BIOS
update procedure, defined in Update Instructions provided with the system update package
downloaded from the Intel web site. Once the update has completed, the recovery jumper is
switched back to its default position and the system is power cycled.
If the BIOS detects a partial BIOS update or the BMC asserts Recovery Mode GPIO, the BIOS
will boot up with Recovery Mode. The difference is that the BIOS boots up to the Error
Manager Page in the BIOS Setup utility. In the BIOS Setup utility, boot device, Shell or Linux for
example, could be selected to perform the BIOS update procedure under Shell or OS
environment.
2.16.2
Field Replaceable Unit (FRU) and Sensor Data Record (SDR) Data
As part of the initial system integration process, the server board/system must have the
proper FRU and SDR data loaded. This ensures that the embedded platform management
system is able to monitor the appropriate sensor data and operate the system with best
cooling and performance. The BMC supports automatic configuration of the manageability
subsystem after changes have been made to the system’s hardware configuration. Once the
system integrator has performed an initial SDR/CFG package update, subsequent
auto-configuration occurs without the need to perform additional SDR updates or provide
other user input to the system when any of the following components are added or removed.

Processors

I/O Modules (dedicated slot modules)

Storage modules such as a SAS module (dedicated slot modules)

Power supplies

Fans

Fan options (e.g. upgrade from non-redundant cooling to redundant cooling)

Intel® Xeon Phi™ co-processor cards

Hot Swap Backplane

Front Panel
Note: The system may not operate with best performance or best/appropriate cooling if the
proper FRU and SDR data is not installed.
26
Revision 1.34
Technical Product Specification
Product Features Overview
2.16.2.1 Loading FRU and SDR Data
The FRU and SDR data can be updated using a standalone FRUSDR utility in the uEFI shell, or
can be done using the OFU utility program under a given operating system. Full FRU and SDR
update instructions are provided with the appropriate system update package (SUP) or OFU
utility which can be downloaded from the Intel web site.
2.16.3
Baseboard Management Controller (BMC) Firmware
See Platform Management chapter.
Revision 1.34
27
Processor Support
3
Technical Product Specification
Processor Support
The server board includes two Socket-R3 (LGA 2011-3) processor sockets and can support
one or two of the Intel® Xeon® processor E5-2600 v3/v4 product family, with a Thermal Design
Power (TDP) of up to 160W.
Note: Previous generation Intel® Xeon® processors are not supported on the Intel® Server Boards
described in this document.
Visit http://www.intel.com/support for a complete list of supported processors.
3.1 Processor Socket Assembly
Each processor socket of the server board is pre-assembled with an Independent Latching
Mechanism (ILM) and Back Plate which allow for secure placement of the processor and
processor heat to the server board.
The following illustration identifies each sub-assembly component.
Figure 28. Processor Socket Assembly
Figure 29. Processor Socket ILM
28
Revision 1.34
Technical Product Specification
Processor Support
The square ILM has an 80 x 80mm heat sink mounting hole pattern.
Note: The pins inside the CPU socket are extremely sensitive. Other than the CPU, no object
should make contact with the pins inside the CPU socket. A damaged CPU Socket pin may
render the socket inoperable, and will produce erroneous CPU or other system errors if
used.
3.2 Processor Thermal Design Power (TDP) Support
To allow optimal operation and long-term reliability of Intel processor-based systems, the
processor must remain within the defined minimum and maximum case temperature (TCASE)
specifications. Thermal solutions not designed to provide sufficient thermal capability may
affect the long-term reliability of the processor and system. The server board described in this
document is designed to support the Intel® Xeon® Processor E5-2600 v3/v4 product family
TDP guidelines up to and including 160W. The compute module described in this document is
designed to support the Intel® Xeon® Processor E5-2600 v3/v4 product family TDP guidelines
up to and including 145W.
Disclaimer Note: Intel Corporation server boards contain a number of high-density VLSI and
power delivery components that need adequate airflow to cool. Intel ensures through its own
chassis development and testing that when Intel server building blocks are used together, the
fully integrated system will meet the intended thermal requirements of these components. It is
the responsibility of the system integrator who chooses not to use Intel developed server
building blocks to consult vendor datasheets and operating parameters to determine the
amount of airflow required for their specific application and environmental conditions. Intel
Corporation cannot be held responsible if components fail or the server board does not
operate correctly when used outside any of their published operating or non-operating limits.
3.3 Processor Population Rules
Note: The server board may support dual-processor configurations consisting of different
processors that meet the defined criteria below, however, Intel does not perform validation
testing of this configuration. In addition, Intel does not guarantee that a server system
configured with unmatched processors will operate reliably. The system BIOS will attempt to
operate with the processors that are not matched but are generally compatible.
For optimal system performance in dual-processor configurations, Intel recommends that
identical processors be installed.
When using a single processor configuration, the processor must be installed into the
processor socket labeled CPU_1.
Note: Some board features may not be functional without having a second processor installed.
See Product Architecture Overview for details.
Revision 1.34
29
Processor Support
Technical Product Specification
When two processors are installed, the following population rules apply:

Both processors must be of the same processor family.

Both processors must have the same number of cores.

Both processors must have the same cache sizes for all levels of processor cache
memory.
Processors with different core frequencies can be mixed in a system, given the prior rules are
met. If this condition is detected, all processor core frequencies are set to the lowest common
denominator (highest common speed) and an error is reported.
Processors that have different Intel® Quickpath (QPI) Link Frequencies may operate together if
they are otherwise compatible and if a common link frequency can be selected. The common
link frequency would be the highest link frequency that all installed processors can achieve.
Processor stepping within a common processor family can be mixed as long as it is listed in
the processor specification updates published by Intel Corporation.
3.4 Processor Initialization Error Summary
The following table describes mixed processor conditions and recommended actions for all
Intel® Server Boards and Intel® Server Systems designed around the Intel® Xeon® processor E52600 v3/v4 product family and Intel® C612 chipset product family architecture. The errors fall
into one of the following categories:

Fatal: If the system can boot, POST will halt and display the following message:
“Unrecoverable fatal error found. System will not boot until the error is resolved
Press <F2> to enter setup”
When the <F2> key on the keyboard is pressed, the error message is displayed on the
Error Manager screen, and an error is logged to the System Event Log (SEL) with the
POST Error Code.
This operation will occur regardless of whether the BIOS Setup option “Post Error
Pause” is set to Enable or Disable.
If the system is not able to boot, the system will generate a beep code consisting of 3
long beeps and 1 short beep. The system cannot boot unless the error is resolved. The
faulty component must be replaced.
The System Status LED will be set to a steady Amber color for all Fatal Errors that are
detected during processor initialization. A steady Amber System Status LED indicates
that an unrecoverable system failure condition has occurred.

30
Major: If the BIOS Setup option for “Post Error Pause” is Enabled, and a Major error is
detected, the system will go directly to the Error Manager screen in BIOS Setup to
display the error, and logs the POST Error Code to SEL. Operator intervention is
required to continue booting the system.
Revision 1.34
Technical Product Specification
Processor Support
If the BIOS Setup option for “POST Error Pause” is Disabled, and a Major error is
detected, the Post Error Code may be displayed to the screen, will be logged to the
BIOS Setup Error Manager, an error event will be logged to the System Event Log
(SEL), and the system will continue to boot.

Minor: An error message may be displayed to the screen, the error will be logged to
the BIOS Setup Error Manager, and the POST Error Code is logged to the SEL. The
system continues booting in a degraded state. The user may want to replace the
erroneous unit. The POST Error Pause option setting in the BIOS setup does not have
any effect on this error.
Table 5. Mixed Processor Configurations Error Summary
Error
Processor family not
Identical
Severity
Fatal
System Action
The BIOS detects the error condition and responds as follows:
 Halts at POST Code 0xE6.
 Halts with 3 long beeps and 1 short beep.
 Takes Fatal Error action (see above) and will not boot until the
fault condition is remedied.
Processor model not
Identical
Fatal
The BIOS detects the error condition and responds as follows:
 Logs the POST Error Code into the System Event Log (SEL).
 Alerts the BMC to set the System Status LED to steady Amber.
 Displays “0196: Processor model mismatch detected” message
in the Error Manager.
 Takes Fatal Error action (see above) and will not boot until the
fault condition is remedied.
Processor cores/threads not
identical
Fatal
The BIOS detects the error condition and responds as follows:
 Halts at POST Code 0xE5.
 Halts with 3 long beeps and 1 short beep.
 Takes Fatal Error action (see above) and will not boot until the
fault condition is remedied.
Processor cache not
identical
Fatal
The BIOS detects the error condition and responds as follows:
 Halts at POST Code 0xE5.
 Halts with 3 long beeps and 1 short beep.
 Takes Fatal Error action (see above) and will not boot until the
fault condition is remedied.
Revision 1.34
31
Processor Support
Error
Processor frequency (speed)
not identical
Technical Product Specification
Severity
Fatal
System Action
The BIOS detects the processor frequency difference, and
responds as follows:
 Adjusts all processor frequencies to the highest common
frequency.
 No error is generated – this is not an error condition.
 Continues to boot the system successfully.
If the frequencies for all processors cannot be adjusted to be the
same, then this is an error, and the BIOS responds as follows:
 Logs the POST Error Code into the SEL.
 Alerts the BMC to set the System Status LED to steady Amber.
 Does not disable the processor.
 Displays “0197: Processor speeds unable to synchronize”
message in the Error Manager.
 Takes Fatal Error action (see above) and will not boot until the
fault condition is remedied.
Processor Intel® QuickPath
Interconnect link
frequencies not identical
Fatal
The BIOS detects the QPI link frequencies and responds as follows:
 Adjusts all QPI interconnect link frequencies to the highest
common frequency.
 No error is generated – this is not an error condition.
 Continues to boot the system successfully.
If the link frequencies for all QPI links cannot be adjusted to be
the same, then this is an error, and the BIOS responds as follows:
 Logs the POST Error Code into the SEL.
 Alerts the BMC to set the System Status LED to steady Amber.
 Displays “0195: Processor Intel(R) QPI link frequencies unable
to synchronize” message in the Error Manager.
 Does not disable the processor.
 Takes Fatal Error action (see above) and will not boot until the
fault condition is remedied.
Processor microcode update
missing
Minor
The BIOS detects the error condition and responds as follows:
 Logs the POST Error Code into the SEL.
 Displays “818x: Processor 0x microcode update not found”
message in the Error Manager or on the screen.
 The system continues to boot in a degraded state, regardless of
the setting of POST Error Pause in the Setup.
Processor microcode update Major
failed
The BIOS detects the error condition and responds as follows:
 Logs the POST Error Code into the SEL.
 Displays “816x: Processor 0x unable to apply microcode
update” message in the Error Manager or on the screen.
 Takes Major Error action. The system may continue to boot in a
degraded state, depending on the setting of POST Error Pause
in Setup, or may halt with the POST Error Code in the Error
Manager waiting for operator intervention.
32
Revision 1.34
Technical Product Specification
Processor Support
3.5 Processor Function Overview
The Intel® Xeon® processor E5-2600 v3/v4 product family combines several key system
components into a single processor package, including the CPU cores, Integrated Memory
Controller (IMC), and Integrated IO Module (IIO). In addition, each processor package includes
two Intel® QuickPath Interconnect point-to-point links capable of up to 9.6 GT/s, up to 40 lanes
of PCI 3.0 Express* links capable of 8.0 GT/s, and four lanes of DMI2/PCI Express* 2.0 interface
with a peak transfer rate of 4.0 GT/s. The processor supports up to 46 bits of physical address
space and 48 bits of virtual address space.
The following sections will provide an overview of the key processor features and functions
that help to define the architecture, performance, and supported functionality of the server
board. For more comprehensive processor specific information, refer to the Intel® Xeon®
processor E5-2600 v3/v4 product family documents listed in the Reference Documents list.
3.5.1 Processor Core Features

Up to 12 execution cores (Intel® Xeon® processor E5-2600 v3/v4 product family)

When enabled, each core can support two threads (Intel® Hyper-Threading
Technology)

46-bit physical addressing and 48-bit virtual addressing

1 GB large page support for server applications

A 32-KB instruction and 32-KB data first-level cache (L1) for each core

A 256-KB shared instruction/data mid-level (L2) cache for each core

Up to 2.5 MB per core instruction/data last level cache (LLC)
3.5.2 Supported Technologies

Intel® Virtualization Technology (Intel® VT) for Intel® 64 and IA-32 Intel® Architecture
(Intel® VT-x)

Intel® Virtualization Technology for Directed I/O (Intel® VT-d)

Execute Disable

Advanced Encryption Standard (AES)

Intel® Hyper-Threading Technology

Intel® Turbo Boost Technology

Enhanced Intel SpeedStep® Technology

Intel® Advanced Vector Extensions 2 (Intel® AVX2)

Intel® Node Manager 3.0

Intel® Secure Key

Intel® OS Guard

Intel® Quick Data Technology
Revision 1.34
33
Processor Support
3.5.2.1
Technical Product Specification
Intel® Virtualization Technology (Intel® VT) for Intel® 64 and IA-32 Intel®
Architecture (Intel® VT-x)
Hardware support in the core to improve the virtualization performance and robustness. Intel®
VT-x specifications and functional descriptions are included in the Intel® 64 and IA-32
Architectures Software Developer’s Manual.
3.5.2.2
Intel® Virtualization Technology for Directed I/O (Intel® VT-d)
Hardware support in the core and uncore implementations to support and improve I/O
virtualization performance and robustness.
3.5.2.3
Execute Disable
Intel's Execute Disable Bit functionality can help prevent certain classes of malicious buffer
overflow attacks when combined with a supporting operating system. This allows the
processor to classify areas in memory by where application code can execute and where it
cannot. When a malicious worm attempts to insert code in the buffer, the processor disables
code execution, preventing damage and worm propagation.
3.5.2.4
Advanced Encryption Standard (AES)
These instructions enable fast and secure data encryption and decryption, using the Advanced
Encryption Standard (AES)
3.5.2.5
Intel® Hyper-Threading Technology
The processor supports Intel® Hyper-Threading Technology (Intel® HT Technology), which
allows an execution core to function as two logical processors. While some execution
resources such as caches, execution units, and buses are shared, each logical processor has its
own architectural state with its own set of general-purpose registers and control registers.
This feature must be enabled via the BIOS and requires operating system support.
3.5.2.6
Intel® Turbo Boost Technology
Intel® Turbo Boost Technology is a feature that allows the processor to opportunistically and
automatically run faster than its rated operating frequency if it is operating below power,
temperature, and current limits. The result is increased performance in multi-threaded and
single threaded workloads. It should be enabled in the BIOS for the processor to operate with
maximum performance.
3.5.2.7
Enhanced Intel SpeedStep® Technology
The processor supports Enhanced Intel SpeedStep® Technology (EIST) as an advanced means
of enabling very high performance while also meeting the power conservation needs of the
platform.
Enhanced Intel SpeedStep® Technology builds upon that architecture using design strategies
that include the following:
34
Revision 1.34
Technical Product Specification
Processor Support

Separation between Voltage and Frequency changes. By stepping voltage up and
down in small increments separately from frequency changes, the processor is able to
reduce periods of system unavailability (which occur during frequency change). Thus,
the system is able to transition between voltage and frequency states more often,
providing improved power/performance balance.

Clock Partitioning and Recovery. The bus clock continues running during state
transition, even when the core clock and Phase-Locked Loop are stopped, which
allows logic to remain active. The core clock is also able to restart more quickly under
Enhanced Intel SpeedStep® Technology.
3.5.2.8
Intel® Advanced Vector Extensions 2 (Intel® AVX2)
Intel® Advanced Vector Extensions 2.0 (Intel® AVX2) is the latest expansion of the Intel
instruction set. Intel® AVX2 extends the Intel® Advanced Vector Extensions (Intel® AVX) with
256-bit integer instructions, floating-point fused multiply add (FMA) instructions and gather
operations. The 256-bit integer vectors benefit math, codec, image and digital signal
processing software. FMA improves performance in face detection, professional imaging, and
high performance computing. Gather operations increase vectorization opportunities for many
applications. In addition to the vector extensions, this generation of Intel processors adds new
bit manipulation instructions useful in compression, encryption, and general purpose
software.
3.5.2.9
Intel® Node Manager 3.0
Intel® Node Manager 3.0 enables the PTAS-CUPS (Power Thermal Aware Scheduling Compute Usage Per Second) feature of the Intel Server Platform Services 3.0 Intel ME
firmware. This is in essence a grouping of separate platform functionalities that provide
Power, Thermal, and Utilization data that together offer an accurate, real time characterization
of server workload. These functionalities include the following:

Computation of Volumetric Airflow

New synthesized Outlet Temperature sensor

CPU, memory, and I/O utilization data (CUPS)
This PTAS-CUPS data, can then be used in conjunction with the Intel® Server Platform Services
Intel® Node Manager 3.0 power monitoring or controls and a remote management application
(such as the Intel® Data Center Manager [Intel® DCM]) to create a dynamic, automated, closedloop data center management and monitoring system.
3.5.2.10 Intel® Secure Key
The Intel® 64 and IA-32 Architectures instruction RDRAND and its underlying Digital Random
Number Generator (DRNG) hardware implementation. Among other things, the Digital Random
Number Generator (DRNG) using the RDRAND instruction is useful for generating high-quality
keys for cryptographic protocols.
Revision 1.34
35
Processor Support
Technical Product Specification
3.5.2.11 Intel® OS Guard
Protects the operating system (OS) from applications that have been tampered with or hacked
by preventing an attack from being executed from application memory. Intel® OS Guard also
protects the OS from malware by blocking application access to critical OS vectors.
3.6 Processor Heat Sink
Two types of heat sinks are included in the compute module package.

On CPU 1 – 1U Standard Cu/Al 91.5mm x 91.5mm Heat Sink (Rear Heat Sink)

On CPU 2 – 1U Standard Ex-Al 91.5mm x 91.5mm Heat Sink (Front Heat Sink)
Warning: The two heat sinks are NOT interchangeable.
This heat sink is designed for optimal cooling and performance. To achieve better cooling
performance, you must properly attach the heat sink bottom base with TIM (thermal interface
material). ShinEtsu* G-751 or 7783D or Honeywell* PCM45F TIM is recommended. The
mechanical performance of the heat sink must satisfy mechanical requirement of the
processor.
Figure 30. Processor Heat Sink Overview
Note: The passive heat sink is Intel standard thermal solution for 1U/2U rack chassis.
36
Revision 1.34
Technical Product Specification
4
Memory Support
Memory Support
This chapter describes the architecture that drives the memory subsystem, supported
memory types, memory population rules, and supported memory RAS features.
4.1
Memory Subsystem Architecture
Figure 31. Integrated Memory Controller Functional Block Diagram
Note: This generation server board has support for DDR4 DIMMs only. DDR3 DIMMs are not
supported on this generation server board.
Each installed processor includes two integrated memory controllers (IMC) capable of
supporting two memory channels each. Each memory channel is capable of supporting up to
three DIMMs. The processor IMC supports the following:

Registered DIMMs (RDIMMs), and Load Reduced DIMMs (LRDIMMs) are supported

DIMMs of different types may not be mixed – this is a Fatal Error in memory
initialization

DIMMs composed of 4 Gb or 8 Gb Dynamic Random Access Memory (DRAM)
technology

DIMMs using x4 or x8 DRAM technology

DIMMs organized as Single Rank (SR), Dual Rank (DR), or Quad Rank (QR)

Maximum of 8 ranks per channel

DIMM sizes of 4 GB, 8 GB, 16 GB, or 32 GB depending on ranks and technology

DIMM speeds of 1600, 1866, or 2133 MT/s (MegaTransfers/second)

Only Error Correction Code (ECC) enabled RDIMMs or LRDIMMs are supported

Only RDIMMs and LRDIMMs with integrated Thermal Sensor On Die (TSOD) are
supported

Memory RASM Support:
o
DRAM Single Device Data Correction (SDDCx4)
o
Memory Disable and Map out for FRB
o
Data scrambling with command and address
o
DDR4 Command/Address parity check and retry
Revision 1.34
37
Memory Support
o
Intra-socket memory mirroring
o
Memory demand and patrol scrubbing
o
HA and IMC corrupt data containment
o
Rank level memory sparing
o
Multi-rank level memory sparing
o
Failed DIMM isolation
Technical Product Specification
4.1.1 IMC Modes of Operation
A memory controller can be configured to operate in one of two modes, and each IMC
operates separately.


Independent mode: This is also known as performance mode. In this mode each DDR
channel is addressed individually via burst lengths of 8 bytes.
o
All processors support SECDED ECC with x8 DRAMs in independent mode.
o
All processors support SDDC with x4 DRAMs in independent mode.
Lockstep mode: This is also known as RAS mode. Each pair of channels shares a Write
Push Logic unit to enable lockstep. The memory controller handles all cache lines
across two interfaces on an IMC. The DRAM controllers in the same IMC share a
common address decode and DMA engines for the mode. The same address is used
on both channels, such that an address error on any channel is detectable by bad ECC.
o
All processors support SDDC with x4 or x8 DRAMs in lockstep mode.
For Lockstep Channel Mode and Mirroring Mode, processor channels are paired together as a
“Domain”.

CPU1 Mirroring/Lockstep Domain 1 = Channel A + Channel B

CPU1 Mirroring/Lockstep Domain 2 = Channel C + Channel D

CPU2 Mirroring/Lockstep Domain 1 = Channel E + Channel F

CPU2 Mirroring/Lockstep Domain 2 = Channel G + Channel H
The schedulers within each channel of a domain will operate in lockstep, they will issue
requests in the same order and time and both schedulers will respond to an error in either one
of the channels in a domain. Lockstep refers to splitting cache lines across channels. The same
address is used on both channels, such that an address error on any channel is detectable by
bad ECC. The ECC code used by the memory controller can correct 1/18th of the data in a
code word. For x8 DRAMs, since there are 9 x8 DRAMs on a DIMM, a code word must be split
across 2 DIMMs to allow the ECC to correct all the bits corrupted by an x8 DRAM failure.
For RAS modes that require matching populations, the same slot positions across channels
must hold the same DIMM type with regards to number of ranks, number of banks, number of
rows, and number of columns. DIMM timings do not have to match but timings will be set to
support all DIMMs populated (that is, DIMMs with slower timings will force faster DIMMs to the
slower common timing modes).
38
Revision 1.34
Technical Product Specification
Memory Support
4.1.2 Memory RASM Features

DRAM Single Device Data Correction (SDDC): SDDC provides error checking and
correction that protects against a single x4 DRAM device failure (hard-errors) as well as
multi-bit faults in any portion of a single DRAM device on a DIMM (require lockstep
mode for x8 DRAM device based DIMM).

Memory Disable and Map out for FRB: Allows memory initialization and booting to
OS even when a memory fault occurs.

Data Scrambling with Command and Address: Scrambles the data with address and
command in "write cycle" and unscrambles the data in "read cycle". This feature
addresses reliability by improving signal integrity at the physical layer, and by assisting
with detection of an address bit error.

DDR4 Command/Address Parity Check and Retry: DDR4 technology based
CMD/ADDR parity check and retry with following attributes:
o
CMD/ADDR Parity error address logging
o
CMD/ADDR Retry

Intra-Socket Memory Mirroring: Memory Mirroring is a method of keeping a duplicate
(secondary or mirrored) copy of the contents of memory as a redundant backup for
use if the primary memory fails. The mirrored copy of the memory is stored in memory
of the same processor socket. Dynamic (without reboot) failover to the mirrored
DIMMs is transparent to the OS and applications. Note that with Memory Mirroring
enabled, only half of the memory capacity of both memory channels is available.

Memory Demand and Patrol Scrubbing: Demand scrubbing is the ability to write
corrected data back to the memory once a correctable error is detected on a read
transaction. Patrol scrubbing proactively searches the system memory, repairing
correctable errors. It prevents accumulation of single-bit errors.

HA and IMC Corrupt Data Containment: Corrupt Data Containment is a process of
signaling memory patrol scrub uncorrected data errors synchronous to the
transaction, which enhances the containment of the fault and improving the reliability
of the system.

Rank Level / Multi Rank Level Memory Sparing: Dynamic fail-over of failing ranks to
spare ranks behind the same memory controller. With Multi Rank, up to four ranks out
of a maximum of eight ranks can be assigned as spare ranks. Memory mirroring is not
supported when memory sparing is enabled.

Failed DIMM Isolation: The ability to identify a specific failing DIMM, thereby enabling
the user to replace only the failed DIMM(s). In case of uncorrected error and lockstep
mode, only DIMM-pair level isolation granularity is supported.
Revision 1.34
39
Memory Support
Technical Product Specification
4.2 Supported Memory
Table 6. DDR4 DIMM Support Guidelines
4.3 Memory Slot Identification and Population Rules
Note: Although mixed DIMM configurations are supported, Intel only performs platform
validation on systems that are configured with identical DIMMs installed.
40

Each installed processor provides four channels of memory. On the Intel® Server Board
S2600KPR product family each memory channel supports one memory slot, for a total
possible eight DIMMs installed.

The memory channels from processor socket 1 are identified as Channel A, B, C, and D.
The memory channels from processor socket 2 are identified as Channel E, F, G, and H.

The silk screened DIMM slot identifiers on the board provide information about the
channel, and therefore the processor to which they belong. For example, DIMM_A1 is
the first slot on Channel A on processor 1; DIMM_E1 is the first DIMM socket on
Channel E on processor 2.

The memory slots associated with a given processor are unavailable if the
corresponding processor socket is not populated.

A processor may be installed without populating the associated memory slots
provided a second processor is installed with associated memory. In this case, the
memory is shared by the processors. However, the platform suffers performance
degradation and latency due to the remote memory.
Revision 1.34
Technical Product Specification
Memory Support

Processor sockets are self-contained and autonomous. However, all memory
subsystem support (such as Memory RAS and Error Management) in the BIOS setup is
applied commonly across processor sockets.

All DIMMs must be DDR4 DIMMs.

Mixing of LRDIMM with any other DIMM type is not allowed per platform.

Mixing of DDR4 operating frequencies is not validated within a socket or across sockets
by Intel. If DIMMs with different frequencies are mixed, all DIMMs run at the common
lowest frequency.

A maximum of eight logical ranks (ranks seen by the host) per channel is allowed.
On the Intel® Server Board S2600KP product family, a total of eight DIMM slots are provided
(two CPUs – four channels per CPU and one DIMM per channel). The nomenclature for DIMM
sockets is detailed in the following table.
Table 7. DIMM Nomenclature
(0)
Processor Socket 1
(1)
(2)
(3)
(0)
Processor Socket 2
(1)
(2)
(3)
Channel A
Channel B
Channel C
Channel D
Channel E
Channel F
Channel G
Channel H
A1
B1
C1
D1
E1
F1
G1
H1
Figure 32. DIMM Slot Identification
The following are the DIMM population requirements.
Table 8. Supported DIMM Populations
Total DIMM#
1 DIMM
2 DIMMs
3 DIMMs
Processor Socket 1 = Populated
A1
C1
D1
E1
F1
X
X
G1
H1
Mirror Mode Support
No
X
Yes
X
X
X
X
X
X
X
Revision 1.34
B1
Processor Socket 2 = Populated
No
X
No
X
X
No
X
No
41
Memory Support
Total DIMM#
Technical Product Specification
Processor Socket 1 = Populated
Processor Socket 2 = Populated
A1
B1
C1
D1
X
X
X
X
X
X
5 DIMMs
X
X
X
X
X
6 DIMMs
X
X
X
X
X
X
8 DIMMs
X
X
X
X
X
X
4 DIMMs
E1
F1
G1
H1
Mirror Mode Support
Yes
X
X
Yes
No
No
X
X
Yes
4.4 System Memory Sizing and Publishing
The address space configured in a system depends on the amount of actual physical memory
installed, on the RAS configuration, and on the PCI/PCIe configuration. RAS configurations
reduce the memory space available in return for the RAS features. PCI/PCIe devices which
require address space for Memory Mapped IO (MMIO) with 32-bit or 64-bit addressing,
increase the address space in use, and introduce discontinuities in the correspondence
between physical memory and memory addresses.
The discontinuities in addressing physical memory revolve around the 4GB 32-bit addressing
limit. Since the system reserves memory address space just below the 4GB limit, and 32-bit
MMIO is allocated just below that, the addresses assigned to physical memory go up to the
bottom of the PCI allocations, then “jump” to above the 4GB limit into 64-bit space.
4.4.1
Effects of Memory Configuration on Memory Sizing
The system BIOS supports 4 memory configurations – Independent Channel Mode and 3
different RAS Modes. In some modes, memory reserved for RAS functions reduce the amount
of memory available.

Independent Channel Mode: In Independent Channel Mode, the amount of installed
physical memory is the amount of effective memory available. There is no reduction.

Lockstep Mode: For Lockstep Mode, the amount of installed physical memory is the
amount of effective memory available. There is no reduction. Lockstep Mode only
changes the addressing to address two channels in parallel.

Rank Sparing Mode: In Rank Sparing mode, the largest rank on each channel is
reserved as a spare rank for that channel. This reduces the available memory size by
the sum of the sizes of the reserved ranks.
Example: if a system has 2 16GB Quad Rank DIMMs on each of 4 channels on each of 2
processor sockets, the total installed memory will be (((2 * 16GB) * 4 channels) * 2 CPU
sockets) = 256GB.
For a 16GB QR DIMM, each rank would be 4GB. With one rank reserved on each
channel, that would 32GB reserved. So the available effective memory size would be
256GB - 32GB, or 224GB.
42
Revision 1.34
Technical Product Specification

Memory Support
Mirroring Mode: Mirroring creates a duplicate image of the memory that is in use,
which uses half of the available memory to mirror the other half. This reduces the
available memory size to half of the installed physical memory.
Example: if a system has 2 16GB Quad Rank DIMMs on each of 4 channels on each of 2
processor sockets, the total installed memory will be (((2 * 16GB) * 4 channels) * 2 CPU
sockets) = 256GB.
In Mirroring Mode, since half of the memory is reserved as a mirror image, the available
memory size would be 128GB.
4.4.2
Publishing System Memory
There are a number of different situations in which the memory size and/or configuration are
displayed. Most of these displays differ in one way or another, so the same memory
configuration may appear to display differently, depending on when and where the display
occurs.

The BIOS displays the “Total Memory” of the system during POST if Quiet Boot is
disabled in BIOS setup. This is the total size of memory discovered by the BIOS during
POST, and is the sum of the individual sizes of installed DDR4 DIMMs in the system.

The BIOS displays the “Effective Memory” of the system in the BIOS Setup. The term
Effective Memory refers to the total size of all DDR4 DIMMs that are active (not
disabled) and not used as redundant units (see Note below).

The BIOS provides the total memory of the system in the main page of BIOS setup.
This total is the same as the amount described by the first bullet above.

If Quiet Boot is disabled, the BIOS displays the total system memory on the diagnostic
screen at the end of POST. This total is the same as the amount described by the first
bullet above.

The BIOS provides the total amount of memory in the system by supporting the EFI
Boot Service function.

The BIOS provides the total amount of memory in the system by supporting the INT
15h, E820h function. For details, see the Advanced Configuration and Power Interface
Specification.
Note: Some server operating systems do not display the total physical memory installed. What
is displayed is the amount of physical memory minus the approximate memory space used by
system BIOS components. These BIOS components include but are not limited to:

ACPI (may vary depending on the number of PCI devices detected in the system)

ACPI NVS table

Processor microcode

Memory Mapped I/O (MMIO)

Manageability Engine (ME)

BIOS flash
Revision 1.34
43
Memory Support
Technical Product Specification
4.5 Memory Initialization
Memory Initialization at the beginning of POST includes multiple functions, including:

DIMM discovery

Channel training

DIMM population validation check

Memory controller initialization and other hardware settings

Initialization of RAS configurations (as applicable)
There are several errors which can be detected in different phases of initialization. During
early POST, before system memory is available, serious errors that would prevent a system
boot with data integrity will cause a System Halt with a beep code and a memory error code to
be displayed via the POST Code Diagnostic LEDs.
Less fatal errors will cause a POST Error Code to be generated as a Major Error. This POST
Error Code will be displayed in the BIOS Setup Error Manager screen, and will also be logged
to the System Event Log (SEL).
4.5.1.1
DIMM Discovery
Memory initialization begins by determining which DIMM slots have DIMMs installed in them.
By reading the Serial Presence Detect (SPD) information from an SEEPROM on the DIMM, the
type, size, latency, and other descriptive parameters for the DIMM can be acquired.
Potential Error Cases:
44

DIMM SPD does not respond – The DIMM will not be detected, which could result in a
“No usable memory installed” Fatal Error Halt 0xE8 if there are no other detectable
DIMMs in the system. The undetected DIMM could result later in an invalid
configuration if the “no SPD” DIMM is in Slot 1 or 2 ahead of other DIMMs on the same
channel.

DIMM SPD read error – This DIMM will be disabled. POST Error Codes 856x “SPD Error”
and 854x “DIMM Disabled” will be generated. If all DIMMs are failed, this will result in a
Fatal Error Halt 0xE8.

All DIMMs on the channel in higher-numbered sockets behind the disabled DIMM will
also be disabled with a POST Error Code 854x “DIMM Disabled” for each. This could
also result in a “No usable memory installed” Fatal Error Halt 0xE8.

No usable memory installed – If no usable (not failed or disabled) DIMMs can be
detected as installed in the system, this will result in a Fatal Error Halt 0xE8. Other
error conditions which cause DIMMs to fail or be disabled so they are mapped out as
unusable may result in causing this error when no usable DIMM remains in the
memory configuration.
Revision 1.34
Technical Product Specification
4.5.1.2
Memory Support
DIMM Population Validation Check
Once the DIMM SPD parameters have been read they are checked to verify that the DIMMs on
the given channel are installed in a valid configuration. This includes checking for DIMM type,
DRAM type and organization, DRAM rank organization, DIMM speed and size, ECC capability,
and in which memory slots the DIMMs are installed. An invalid configuration may cause the
system to halt.
Potential Error Cases:

Invalid DIMM (type, organization, speed, size) – If a DIMM is found that is not a type
supported by the system, the following error will be generated: POST Error Code
8501 “DIMM Population Error”, and a “Population Error- Fatal Error Halt 0xED”.

Invalid DIMM Installation – The DIMMs are installed incorrectly on a channel, not
following the “Fill Farthest First” rule (Slot 1 must be filled before Slot 2, Slot 2 before
Slot 3). This will result in a POST Error Code 8501 “DIMM Population Error” with the
channel being disabled, and all DIMMs on the channel will be disabled with a POST
Error Code 854x “DIMM Disabled” for each. This could also result in a “No usable
memory installed” Fatal Error Halt 0xE8.

Invalid DIMM Population – A QR RDIMM, or a QR LRDIMM in Direct Map mode which is
installed in Slot3 on a 3 DIMM per channel server board is not allowed. This will result
in a POST Error Code 8501 “DIMM Population Error” and a “Population Error” Fatal
Error Halt 0xED.
Note: 3 QR LRDIMMs on a channel is an acceptable configuration if operating in Rank
Multiplication mode with RM = 2 or 4. In this case each QR LRDIMM appears to be a DR
or SR DIMM.

Mixed DIMM Types – A mixture of RDIMMs and/or LRDIMMs is not allowed. A mixture
of LRDIMMs operating in Direct Map mode and Rank Multiplication mode is also not
allowed. This will result in a POST Error Code 8501 “DIMM Population Error” and
“Population Error” Fatal Error Halt 0xED.

Mixed DIMM Parameters – Within an RDIMM or LRDIMM configuration, mixtures of
valid DIMM technologies, sizes, speeds, latencies, etc., although not supported, will be
initialized and operated on a best efforts basis, if possible.

No usable memory installed – If no enabled and available memory remains in the
system, this will result in a Fatal Error Halt 0xE8.
4.5.1.3
Channel Training
The Integrated Memory Controller registers are programmed at the controller level and the
memory channel level. Using the DIMM operational parameters, read from the SPD of the
DIMMs on the channel, each channel is trained for optimal data transfer between the
integrated memory controller (IMC) and the DIMMs installed on the given channel.
Potential Error Cases:
Revision 1.34
45
Memory Support

4.5.1.4
Technical Product Specification
Channel Training Error – If the Data/Data Strobe timing on the channel cannot be set
correctly so that the DIMMs can become operational, this results in a momentary Error
Display 0xEA, and the channel is disabled. All DIMMs on the channel are marked as
disabled, with POST Error Code 854x “DIMM Disabled” for each. If there are no
populated channels which can be trained correctly, this becomes a Fatal Error Halt
0xEA.
Thermal (CLTT) and Power Throttling
Potential Error Cases:

4.5.1.5
CLTT Structure Error – The CLTT initialization fails due to an error in the data structure
passed in by the BIOS. This results in a Fatal Error Halt 0xEF.
Built-In Self Test (BIST)
Once the memory is functional, a memory test is executed. This is a hardware-based Built In
Self Test (BIST) which confirms minimum acceptable functionality. Any DIMMs which fail are
disabled and removed from the configuration.
Potential Error Cases:

Memory Test Error – The DIMM has failed BIST and is disabled. POST Error Codes
852x “Failed test/initialization” and 854x “DIMM Disabled” will be generated for each
DIMM that fails. Any DIMMs installed on the channel behind the failed DIMM will be
marked as disabled, with POST Error Code 854x “DIMM Disabled”. This results in a
momentary Error Display 0xEB, and if all DIMMs have failed, this will result in a Fatal
Error Halt 0xE8.

No usable memory installed – If no enabled and available memory remains, this will
result in a Fatal Error Halt 0xE8.
The ECC functionality is enabled after all of memory has been cleared to zeroes to make sure
that the data bits and the ECC bits are in agreement.
4.5.1.6
RAS Mode Initialization
If configured, the DIMM configuration is validated for specified RAS mode. If the enabled
DIMM configuration is compliant for the RAS mode selected, then the necessary register
settings are done and the RAS mode is started into operation.
Potential Error Cases:

46
RAS Configuration Failure – If the DIMM configuration is not valid for the RAS mode
which was selected, then the operating mode falls back to Independent Channel
Mode, and a POST Error Code 8500 “Selected RAS Mode could not be configured” is
generated. In addition, a “RAS Configuration Disabled” SEL entry for “RAS
Configuration Status” (BIOS Sensor 02/Type 0Ch/Generator ID 01) is logged.
Revision 1.34
Technical Product Specification
5
Server Board I/O
Server Board I/O
The server board input/output features are provided via the embedded features and functions
of several onboard components including: the Integrated I/O Module (IIO) of the Intel® Xeon®
processor E5-2600 v3/v4 product family, the Intel® C612 chipset, the Intel® Ethernet controller
I350, and the I/O controllers embedded within the Emulex* Pilot-III Management Controller.
See the block diagram for an overview of the features and interconnects of each of the major
subsystem components.
5.1
PCI Express* Support
The Integrated I/O (IIO) module of the Intel® Xeon® processor E5-2600 v3/v4 product family
provides the PCI express interface for general purpose PCI Express* (PCIe) devices at up to
Gen 3 speeds.
The IIO module provides the following PCIe Features:

Compliant with the PCI Express* Base Specification, Revision 2.0 and Revision 3.0

2.5 GHz (Gen1) and 5 GHz (Gen2) and 8 GHz (Gen3)

x16 PCI Express* 3.0 interface supports up to four x4 controllers and is configurable to
4x4 links, 2x8, 2x4\1x8, or 1x16

x8 PCI Express* 3.0 interface supports up to 2 x4 controllers and is configurable to 2x4
or 1x8

Full peer-to-peer support between PCI Express* interfaces

Full support for software-initiated PCI Express* power management

x8 Server I/O Module support

TLP Processing Hints (TPH) for data push to cache

Address Translation Services (ATS 1.0)

PCIe Atomic Operations Completer Capability

Autonomous Linkwidth

x4 DMI2 interface
o
All processors support an x4 DMI2 lane which can be connected to a PCH, or
operate as an x4 PCIe 2.0 port.
5.1.1 PCIe Enumeration and Allocation
The BIOS assigns PCI bus numbers in a depth-first hierarchy, in accordance with the PCI Local
Bus Specification, Revision 2.2. The bus number is incremented when the BIOS encounters a
PCI-PCI bridge device.
Revision 1.34
47
Server Board I/O
Technical Product Specification
Scanning continues on the secondary side of the bridge until all subordinate buses are
assigned numbers. PCI bus number assignments may vary from boot to boot with varying
presence of PCI devices with PCI-PCI bridges.
If a bridge device with a single bus behind it is inserted into a PCI bus, all subsequent PCI bus
numbers below the current bus are increased by one. The bus assignments occur once, early
in the BIOS boot process, and never change during the pre-boot phase.
The BIOS resource manager assigns the PIC-mode interrupt for the devices that are accessed
by the legacy code. The BIOS ensures that the PCI BAR registers and the command registers
for all devices are correctly set up to match the behavior of the legacy BIOS after booting to a
legacy OS. Legacy code cannot make any assumption about the scan order of devices or the
order in which resources are allocated to them.
The BIOS automatically assigns IRQs to devices in the system for legacy compatibility. A
method is not provided to manually configure the IRQs for devices.
5.1.2 PCIe Non-Transparent Bridge (NTB)
PCI Express Non-Transparent Bridge (NTB) acts as a gateway that enables high performance,
low overhead communication between two intelligent subsystems, the local and the remote
subsystems. The NTB allows a local processor to independently configure and control the
local subsystem, provides isolation of the local host memory domain from the remote host
memory domain while enabling status and data exchange between the two domains.
The PCI Express Port 3A of Intel® Xeon® Processor E5-2600 v3/v4 product family can be
configured to be a transparent bridge or an NTB with x4/x8/x16 link width and
Gen1/Gen2/Gen3 link speed. This NTB port could be attached to another NTB port or PCI
Express Root Port on another subsystem. NTB supports three 64bit BARs as configuration
space or prefetchable memory windows that can access both 32bit and 64bit address space
through 64bit BARs.
There are 3 NTB supported configurations:

NTB Port to NTB Port Based Connection (Back-to-Back).

NTB Port to Root Port Based Connection – Symmetric Configuration. The NTB port on
the first system is connected to the root port of the second. The second system’s NTB
port is connected to the root port on the first system making this a fully symmetric
configuration.

NTB Port to Root Port Based Connection – Non-Symmetric Configuration. The root
port on the first system is connected to the NTB port of the second system. It is not
necessary for the first system to be an Intel® Xeon® Processor E5-2600 v3/v4 product
family system.
Note: When NTB is enabled in BIOS Setup, Spread Spectrum Clocking (SSC) will be
automatically disabled.
48
Revision 1.34
Technical Product Specification
Server Board I/O
5.2 Add-in Card Support
The following sub-sections describe the server board features that are directly supported by
the processor IIO module. These include the Riser Card Slots, Network Interface, and
connectors for the optional I/O modules and SAS Module. Features and functions of the Intel®
C612 chipset will be described in its own dedicated section.
Figure 33. Add-in Card Support Block Diagram (S2600KPR)
Note: Maximum two 75W PCIe* cards can be supported with onboard power. More PCIe
devices require extra power.
5.2.1 Riser Card Support
The server board includes features for concurrent support of several add-in card types
including: PCIe add-in cards via 2 riser card slots (RISER_SLOT_1 and RISER_SLOT_3), and
Intel® I/O module options via 1 riser card slot (RISER_SLOT_2). The following illustration
identifies the location of the onboard connector features and general board placement for
add-in modules and riser cards.
Riser Slot #3
Riser Slot #2
Riser Slot #1
Figure 34. Server Board Riser Slots (S2600KPFR)
Following is the scope of PCIe* connection from processors.
Revision 1.34
49
Server Board I/O
Technical Product Specification
Table 9. PCIe* Port Routing – CPU 1
PCI Ports
Port DMI 2/PCIe* x4
Device (D)
D0
Port 1A - x4
D1
CPU 1
Function (F)
F0
F0
On-board Device
Chipset
InfiniBand* on
S2600KPFR
Riser Slot 2 on S2600KPR
Port 1B - x4
D1
F1
InfiniBand* on
S2600KPFR
Riser Slot 2 on S2600KPR
Port 2A - x4
D2
F0
Riser Slot 1
Port 2B - x4
D2
F1
Riser Slot 1
Port 2C - x4
D2
F2
Riser Slot 1
Port 2D - x4
D2
F3
Riser Slot 1
Port 3A - x4
D3
F0
Riser Slot 2
Port 3B - x4
D3
F1
Riser Slot 2
Port 3C - x4
D3
F2
Riser Slot 2
Port 3D - x4
D3
F3
Riser Slot 2
Table 10. PCIe* Port Routing – CPU 2
CPU 2
Function (F)
F0
PCI Ports
Port DMI 2/PCIe* x4
Device (D)
D0
On-board Device
Not connect
Port 1A - x4
D1
F1
Riser Slot 3
Port 1B - x4
D1
F0
Riser Slot 3
Port 2A - x4
D2
F0
Not connect
Port 2B - x4
D2
F1
Not connect
Port 2C - x4
D2
F2
Not connect
Port 2D - x4
D2
F3
Not connect
Port 3A - x4
D3
F0
Riser Slot 3
Port 3B - x4
D3
F1
Riser Slot 3
Port 3C - x4
D3
F2
Riser Slot 3
Port 3D - x4
D3
F3
Riser Slot 3
Notes:
1. All riser slots are defined specially for dedicated risers only. Plugging in a normal PCIe riser
or PCIe add-in card directly causes danger and may burn out the add-in riser or card.
50
Revision 1.34
Technical Product Specification
Server Board I/O
2. Riser slot 3 can be used only in dual processor configurations. Any graphic add-in card in
riser slot 3 cannot output video, meaning that the default video out is still from on-board
integrated BMC.
5.3 Serial ATA (SATA) Support
The server board utilizes two chipset embedded AHCI SATA controllers, identified as SATA
and sSATA (“s” is for secondary), providing for up to ten 6 Gb/sec Serial ATA (SATA) ports.
The AHCI SATA controller provides support for up to six SATA ports on the server board:

Four SATA ports to the bridge board connector and then to the backplane through the
bridge board

One SATA port to the bridge board connector for the one SATA DOM connector on
the bridge board

One SATA port for the SATA DOM connector on the bridge board
The AHCI sSATA controller provides four SATA ports on the server board.
Figure 35. SATA Support
The SATA controller (AHCI Capable Controller 1) and the sSATA controller (AHCI Capable
Controller 2) can be independently enabled and disabled and configured through the <F2>
BIOS Setup Utility under the “Mass Storage Controller Configuration” menu screen.
Table 11. SATA and sSATA Controller BIOS Utility Setup Options
Revision 1.34
SATA Controller
sSATA Controller
AHCI
AHCI
Yes
Supported
AHCI
Enhanced
Yes
AHCI
Disabled
Yes
AHCI
RSTe
Yes
AHCI
ESRT2
Microsoft* Windows Only
Enhanced
AHCI
Yes
51
Server Board I/O
Technical Product Specification
SATA Controller
sSATA Controller
Enhanced
Enhanced
Yes
Supported
Enhanced
Disabled
Yes
Enhanced
RSTe
Yes
Enhanced
ESRT2
Yes
Disabled
AHCI
Yes
Disabled
Enhanced
Yes
Disabled
Disabled
Yes
Disabled
RSTe
Yes
Disabled
ESRT2
Yes
RSTe
AHCI
Yes
RSTe
Enhanced
Yes
RSTe
Disabled
Yes
RSTe
RSTe
Yes
RSTe
ESRT2
No
ESRT2
AHCI
Microsoft* Windows Only
ESRT2
Enhanced
Yes
ESRT2
Disabled
Yes
ESRT2
RSTe
No
ESRT2
ESRT2
Yes
Table 12. SATA and sSATA Controller Feature Support
Feature
Description
AHCI / RAID
Disabled
AHCI / RAID
Enabled
Native Command Queuing (NCQ)
Allows the device to reorder commands for
more efficient data transfers
N/A
Supported
Auto Activate for DMA
Collapses a DMA Setup then DMA Activate
sequence into a DMA Setup only
N/A
Supported
Hot Plug Support
Allows for device detection without power
being applied and ability to connect and
disconnect devices without prior notification
to the system
N/A
Supported
Asynchronous Signal Recovery
Provides a recovery from a loss of signal or
establishing communication after hot plug
N/A
Supported
6 Gb/s Transfer Rate
Capable of data transfers up to 6 Gb/s
Supported
Supported
ATAPI Asynchronous Notification
A mechanism for a device to send a
notification to the host that the device
requires attention
N/A
Supported
Host & Link Initiated Power
Management
Capability for the host controller or device to
request Partial and Slumber interface power
states
N/A
Supported
Staggered Spin-Up
Enables the host the ability to spin up hard
drives sequentially to prevent power load
problems on boot
Supported
Supported
52
Revision 1.34
Technical Product Specification
Server Board I/O
Feature
Description
Command Completion Coalescing
Reduces interrupt and completion overhead
by allowing a specified number of commands
to complete and then generating an interrupt
to process the commands
5.3.1
AHCI / RAID
Disabled
AHCI / RAID
Enabled
N/A
Staggered Disk Spin-Up
Because of the high density of disk drives that can be attached to the onboard AHCI SATA
controller and the sSATA controller, the combined startup power demand surge for all drives
at once can be much higher than the normal running power requirements and could require a
much larger power supply for startup than for normal operations.
In order to mitigate this and lessen the peak power demand during system startup, both the
AHCI SATA controller and the sSATA controller implement a Staggered Spin-Up capability for
the attached drives. This means that the drives are started up separately, with a certain delay
between disk drives starting.
For the onboard SATA controller, Staggered Spin-Up is an option – AHCI HDD Staggered
Spin-Up – in the Setup Mass Storage Controller Configuration screen found in the <F2> BIOS
Setup Utility.
5.4
Embedded SATA RAID Support
The server board has embedded support for two SATA RAID options:

Intel® Rapid Storage Technology (RSTe) 4.0

Intel® Embedded Server RAID Technology 2 (ESRT2) based on LSI* MegaRAID
technology
Using the <F2> BIOS Setup Utility, accessed during system POST, options are available to
enable/disable RAID, and select which embedded software RAID option to use.
Note: RAID partitions created using either RSTe or ESRT2 cannot span across the two
embedded SATA controllers. Only drives attached to a common SATA controller can be
included in a RAID partition.
5.4.1
Intel® Rapid Storage Technology (RSTe) 4.0
Intel® Rapid Storage Technology offers several options for RAID (Redundant Array of
Independent Disks) to meet the needs of the end user. AHCI support provides higher
performance and alleviates disk bottlenecks by taking advantage of the independent DMA
engines that each SATA port offers in the chipset.
Revision 1.34
53
Server Board I/O
Technical Product Specification

RAID Level 0 – Non-redundant striping of drive volumes with performance scaling of
up to six drives, enabling higher throughput for data intensive applications such as
video editing.

Data security is offered through RAID Level 1, which performs mirroring.

RAID Level 10 provides high levels of storage performance with data protection,
combining the fault-tolerance of RAID Level 1 with the performance of RAID Level 0.
By striping RAID Level 1 segments, high I/O rates can be achieved on systems that
require both performance and fault-tolerance. RAID Level 10 requires four hard drives,
and provides the capacity of two drives.

RAID Level 5 provides highly efficient storage while maintaining fault-tolerance on
three or more drives. By striping parity, and rotating it across all disks, fault tolerance
of any single drive is achieved while only consuming one drive worth of capacity. That
is, a 3-drive RAID 5 has the capacity of two drives, or a 4-drive RAID 5 has the capacity
of three drives. RAID 5 has high read transaction rates, with a medium write rate. RAID
5 is well suited for applications that require high amounts of storage while maintaining
fault tolerance.
Note: RAID configurations cannot span across the two embedded AHCI SATA controllers.
By using Intel® RSTe, there is no loss of PCI resources (request/grant pair) or add-in card slot.
Intel® RSTe functionality requires the following:

The RAID option must be enable in <F2> BIOS Setup

Intel® RSTe option must be selected in <F2> BIOS Setup

Intel® RSTe drivers must be loaded for the specified operating system

At least two SATA drives needed to support RAID levels 0 or 1

At least three SATA drives needed to support RAID levels 5 or 10
With Intel® RSTe RAID enabled, the following features are made available:

A boot-time, pre-operating system environment, text mode user interface that allows
the user to manage the RAID configuration on the system. Its feature set is kept simple
to keep size to a minimum, but allows the user to create and delete RAID volumes and
select recovery options when problems occur. The user interface can be accessed by
hitting the <CTRL-I > keys during system POST.

Provide boot support when using a RAID volume as a boot disk. It does this by
providing Int13 services when a RAID volume needs to be accessed by MS-DOS
applications (such as NTLDR) and by exporting the RAID volumes to the System BIOS
for selection in the boot order.

At each boot up, provides the user with a status of the RAID volumes.
5.4.2
Intel® Embedded Server RAID Technology 2 (ESRT2)
Features of ESRT2 include the following:
54
Revision 1.34
Technical Product Specification
Server Board I/O

Based on LSI* MegaRAID Software Stack

Software RAID with system providing memory and CPU utilization

RAID Level 0 – Non-redundant striping of drive volumes with performance scaling up
to six drives, enabling higher throughput for data intensive applications such as video
editing.

Data security is offered through RAID Level 1, which performs mirroring.

RAID Level 10 provides high levels of storage performance with data protection,
combining the fault-tolerance of RAID Level 1 with the performance of RAID Level 0.
By striping RAID Level 1 segments, high I/O rates can be achieved on systems that
require both performance and fault-tolerance. RAID Level 10 requires four hard drives,
and provides the capacity of two drives.

Optional support for RAID Level 5
o
Enabled with the addition of an optionally installed ESRT2 SATA RAID 5 Upgrade
Key (iPN – RKSATA4R5)
o
RAID Level 5 provides highly efficient storage while maintaining fault-tolerance on
three or more drives. By striping parity, and rotating it across all disks, fault
tolerance of any single drive is achieved while only consuming one drive worth of
capacity. That is, a 3-drive RAID 5 has the capacity of two drives, or a 4-drive RAID
5 has the capacity of three drives. RAID 5 has high read transaction rates, with a
medium write rate. RAID 5 is well suited for applications that require high amounts
of storage while maintaining fault tolerance.
Figure 36. SATA RAID 5 Upgrade Key

Maximum drive support = 6 (Maximum on-board SATA port support)

Open Source Compliance = Binary Driver (includes Partial Source files) or Open Source
using MDRAID layer in Linux*
Note: RAID configurations cannot span across the two embedded AHCI SATA controllers.
Revision 1.34
55
Server Board I/O
5.5
Technical Product Specification
Network Interface
On the back edge of the server board there are three RJ45 networking ports; “NIC 1”, “NIC 2”,
and a Dedicated Management Port.
Figure 37. Network Interface Connectors
Network interface support is provided from the onboard Intel® i350 NIC, which is a dual-port,
compact component with two fully integrated GbE Media Access Control (MAC) and Physical
Layer (PHY) ports. The Intel® i350 NIC provides the server board with support for dual LAN
ports designed for 10/100/1000 Mbps operation. Refer to the Intel® i350 Gigabit Ethernet
Controller Datasheet for full details of the NIC feature set.
The NIC device provides a standard IEEE 802.3 Ethernet interface for 1000BASE-T, 100BASETX, and 10BASE-T applications (802.3, 802.3u, and 802.3ab) and is capable of transmitting
and receiving data at rates of 1000 Mbps, 100 Mbps, or 10 Mbps.
Intel® i350 will be used in conjunction with the Emulex* PILOT III BMC for in band Management
traffic. The BMC will communicate with Intel® i350 over an NC-SI interface (RMII physical). The
NIC will be on standby power so that the BMC can send management traffic over the NC-SI
interface to the network during sleep states S4 and S5.
The NIC supports the normal RJ-45 LINK/Activity speed LEDs as well as the Preset ID function.
These LEDs are powered from a Standby voltage rail.
The link/activity LED (at the right of the connector) indicates network connection when on,
and transmit/receive activity when blinking. The speed LED (at the left of the connector)
indicates 1000-Mbps operation when green, 100-Mbps operation when amber, and 10-Mbps
when off. The following table provides an overview of the LEDs.
56
Revision 1.34
Technical Product Specification
Server Board I/O
LED Color
Green/Amber (B)
Green (A)
LED State
NIC State
Off
10 Mbps
Amber
100 Mbps
Green
1000 Mbps
On
Active Connection
Blinking
Transmit/Receive activity
Figure 38. RJ45 NIC Port LED
5.5.1 MAC Address Definition
The Intel® Server Board S2600KP product family has the following four MAC addresses
assigned to it at the Intel factory:

NIC 1 Port 1 MAC address (for OS usage)

NIC 1 Port 2 MAC address = NIC 1 Port 1 MAC address + 1 (for OS usage)

BMC LAN channel 1 MAC address = NIC1 Port 1 MAC address + 2

BMC LAN channel 3 (Dedicated Server Management NIC) MAC address = NIC1 Port 1
MAC address + 3
The Intel® Server Board S2600KPR has a white MAC address sticker included with the board.
The sticker displays the NIC 1 Port 1 MAC address in both bar code and alphanumeric formats.
5.5.2 LAN Manageability
Port 1 of the Intel® I350 NIC will be used by the BMC firmware to send management traffic.
5.6 Video Support
There is a video controller which is actually a functional block included in the Baseboard
Management Controller integrated on the server board.
There is a PCIe x1 Gen1 link between the BMC video controller and the Integrated IO of the
processor in CPU Socket 1, which is the Legacy Processor Socket for boot purposes. During
the PCI enumeration and initialization, 16 MB of memory is reserved for video use.
The Onboard Video Controller can support the 2D video resolutions shown in the following
table.
Revision 1.34
57
Server Board I/O
Technical Product Specification
Table 13. Onboard Video Resolution and Refresh Rate (Hz)
2D Mode
2D Video Mode Support (Color Bit)
Resolution
8 bpp
16 bpp
24 bpp
32 bpp
640x480
60, 72, 75, 85
60, 72, 75, 85
Not supported
60, 72, 75, 85
800x600
60, 72, 75, 85
60, 72, 75, 85
Not supported
60, 72, 75, 85
1024x768
60, 70, 75, 85
60, 70, 75, 85
Not supported
60, 70, 75, 85
1152x864
75
75
75
75
1280x800
60
60
60
60
1280x1024
60
60
60
60
1440x900
60
60
60
60
1600x1200
60
60
Not Supported
Not Supported
1680x1050
60
60
Not Supported
Not Supported
1920x1080
60
60
Not Supported
Not Supported
1920x1200
60
60
Not Supported
Not Supported
The user can use an add-in PCIe video adapter to either replace or complement the Onboard
Video Controller.
There are enable/disable options in BIOS Setup screen for “Add-in Video Adapter” and
“Onboard Video”.

When Onboard Video is Enabled, and Add-in Video Adapter is also Enabled, then both
video displays can be active. The onboard video is still the primary console and active
during BIOS POST; the add-in video adapter would be active under an OS
environment with the video driver support.

When Onboard Video is Enabled, and Add-in Video Adapter is Disabled, then only the
onboard video would be active.

When Onboard Video is Disabled, and Add-in Video Adapter is Enabled, then only the
add-in video adapter would be active.
5.7 Universal Serial Bus (USB) Ports
There are eight USB 2.0 ports and six USB 3.0 ports available from Intel® C612 chipset. All
ports are high-speed, full-speed and low-speed capable. A total of five USB 2.0 dedicated
ports are used. The USB port distribution is as follows:
58

Emulex* BMC PILOT III consumes two USB 2.0 ports (one USB 1.1 and one USB 2.0).

Two external USB 2.0 ports on the rear side of server board.

One internal USB 2.0 port for extension of front-panel USB port on server board.

One internal USB 2.0 port on bridge board of the compute module.
Revision 1.34
Technical Product Specification
Server Board I/O
Figure 39. USB Ports Block Diagram
5.8
Serial Port
The server board has support for one serial port - Serial Port A.
Serial Port A
Figure 40. Serial Port A Location
Serial Port A is an internal 10-pin DH-10 connector labeled “Serial_A”.
5.9 InfiniBand* Adapter
Intel® Server Board S2600KPFR is populated with a new generation InfiniBand* adapter device.
Mellanox* Connect-IB* providing single port 10/20/40/56 Gb/s InfiniBand* interfaces. The
functional diagram is as follows.
Major features and functions include:

Single InfiniBand* Port: SDR/DDR/QDR/FDR10/FDR with port remapping in firmware.

Performance optimization: Achieving single port line-rate bandwidth.

PCI Express 3.0* x8 to achieve 2.5GT/s, 5GT/s, 8GT/s link rate per lane.

Low power consumption: 7.9 Watt typical.
Revision 1.34
59
Server Board I/O
Technical Product Specification
5.9.1 Device Interfaces
Following is a list of major interfaces of Mellanox* Connect-IB* chip:

Clock and Reset signals: Include core clock input and chip reset signals.

Uplink Bus: The PCI Express* bus is a high-speed uplink interface used to connect
Connect-IB* to the host processor. The Connect-IB* supports a PCI Express 3.0* x8
uplink connection with transfer rates of 2.5GT/s, 5GT/s, and 8GT/s per lane.
Throughout this document, the PCI Express* interface may also be referred to as the
“uplink” interface.

Network Interface: Single network port connecting the device to a network fabric in
one of the configurations described in the following table.
Table 14. Network Port Configuration
Port Configured as
10/20/40/56 Gb/s InfiniBand*

Flash interface: Chip initialization and host boot.

I2C Compatible Interfaces: For chip, QSFP+ connector, and chassis configure and
monitor.

Management Link: Connect to BMC through SMBus* and NC-SI.

Others including: MDIO, GPIO, and JTAG.
Notes:
The following features are unsupported in the current ConnectX-IB* firmware

60
Service types not supported:

SyncUMR

Mellanox transport

PTP

RAW IPv6

PTP (ieee 1588)

SR-IOV

Connect-IB® currently supports only a single physical function model

INT-A not supported for EQs only MSI-X
Revision 1.34
Technical Product Specification

PCI VPD write flow (RO flow supported)

Streaming receive queue (STRQ) and collapsed CQ

Precise clock synchronization over the network (IEEE 1588)

Data integrity validation of control structures

NC-SI interface is not enabled in Connect-IB* firmware

PCIe Function Level Reset (FLR)
5.9.2 Quad Small Form-factor Pluggable (QSFP+) Connector
Port of the Mellanox* ConnectX-IB* is connected to a single QSFP+ connector on Intel® Server
Board S2600KPR (available on SKU: S2600KPFR).
The QSFP+ module and all pins shall withstand 500V electrostatic discharge based on the
Human Body Model per JEDEC JESD22-A114-B.
The module shall meet ESD requirements given in EN61000-4-2, criterion B test specification
such that when installed in a properly grounded cage and chassis the units are subjected to
12KV air discharges during operation and 8KV direct contact discharges to the case.
Revision 1.34
61
Connector and Header
6
Technical Product Specification
Connector and Header
6.1 Power Connectors
6.1.1 Main Power Connector
To facilitate customers who want to cable to this board from a power supply, the power
connector is implemented through two 6pin Minifit Jr* connectors, which can be used to
deliver 12amps per pin or 60+Amps total. Note that no over-voltage protective circuits will
exist on the board.
Table 15. Main Power Supply Connector 6-pin 2x3 Connector
Pin
1
Signal Name
GND
Pin
4
Signal Name
+12V
2
GND
5
+12V
3
GND
6
+12V
6.1.2 Backup Power Connector
The backup (or auxiliary) power connector is used for power control when the baseboard is
used in a 3rd party chassis.
It is expected that the customer will use only pin 7 or pin 8 for delivering standby power. The
connector is capable of delivering up to 3 amps. Connector type is the AMPMODU MTE
Interconnection System or equivalent.
Table 16. Backup Power Connector
62
Pin
1
Signal Name
SMB_PMBUS_CLK
2
SMB_PMBUS_DATA
3
IRQ_SML1_PMBUS_ALERT_N
4
GND
5
PWRGD_PS_PWROK
6
FM_PS_EN_PSU
7
P5V_STBY
8
P12V_STBY
Revision 1.34
Technical Product Specification
Connector and Header
6.2 System Management Headers
6.2.1 Intel® Remote Management Module 4 (Intel® RMM4) Lite Connector
A 7-pin Intel® RMM4 Lite connector is included on the server board to support the optional
Intel® Remote Management Module 4. There is no support for third-party management cards
on this server board.
Note: This connector is not compatible with the Intel® Remote Management Module 3 (Intel®
RMM3).
Table 17. Intel® RMM4 Lite Connector
1
Pin
Signal Description
P3V3_AUX
2
Pin
Signal Description
SPI_RMM4_LITE_DI
3
Key Pin
4
SPI_RMM4_LITE_CLK
5
SPI_RMM4_LITE_DO
6
GND
7
SPI_RMM4_LITE_CS_N
8
GND
6.2.2 IPMB Header
Table 18. IPMB Header
Pin
1
Signal Name
SMB_IPMB_5VSB_DAT
Description
BMC IPMB 5V standby data line
2
GND
Ground
3
SMB_IPMB_5VSB_CLK
BMC IPMB 5V standby clock line
4
P5V_STBY
+5V standby power
6.2.3 Control Panel Connector
This connector is used for front panel control when the baseboard is used in a 3rd party
chassis.
Table 19. Control Panel Connector
Revision 1.34
Pin
1
Signal
FP_ID_LED_N
Pin
2
Signal
PU_FP_P5V_AUX_0
3
LED_HDD_ACTIVITY_N
4
PU_FP_P5V_AUX_1
5
FP_PWR LED_N
6
PU_FP_P5V_AUX_2
7
GND
8
FP_PWR_BTN_N
9
GND
10
FP_ID_BTN_N
11
FP_RST_BTN_N
12
spare
63
Connector and Header
Technical Product Specification
6.3 Bridge Board Connector
The bridge board delivers SATA/SAS signals, disk backplane management signals, BMC
SMBus*es as well as control panel and miscellaneous compute module specific signals.
Table 20. Bridge Board Connector
Pin
80
Signal
SATA_SAS_SEL
Pin
79
Signal
GND
78
GND
77
GND
76
SATA6G_P0_RX_DP
75
SATA6G_P0_TX_DN
74
SATA6G_P0_RX_DN
73
SATA6G_P0_TX_DP
72
GND
71
GND
70
SATA6G_P1_TX_DP
69
SATA6G_P1_RX_DN
68
SATA6G_P1_TX_DN
67
SATA6G_P1_RX_DP
66
GND
65
GND
64
SATA6G_P2_RX_DP
63
SATA6G_P2_TX_DN
62
SATA6G_P2_RX_DN
61
SATA6G_P2_TX_DP
60
GND
59
GND
58
SATA6G_P3_TX_DP
57
SATA6G_P3_RX_DN
56
SATA6G_P3_TX_DN
55
SATA6G_P3_RX_DP
54
GND
53
GND
52
SGPIO SATA_CLOCK
51
PWRGD_PSU
50
BMC_NODE_ID1
49
SGPIO_SATA_LOAD
48
BMC_NODE_ID2
47
SGPIO_SATA_DATAOUT0
46
BMC_NODE_ID3
45
SGPIO_SATA_DATAOUT1
KEY
64
44
BMC_NODE_ID4
43
PS_EN_PSU_N
42
SPA_SIN_N
41
IRQ_SML1_PMBUS_ALERT_N
40
SPA_SOUT_N
39
GND
38
FP_NMI BTN_N
37
SMB_PMBUS_CLK
36
FP_PWR BTN_N
35
SMB_PMBUS_DATA
34
FP_RST BTN_N
33
GND
32
FP_ID_BTN_N
31
SMB_HSBP_STBY_LVC3_CLK
30
FP_ID_LED_N
29
SMB_HSBP_STBY_LVC3_DATA
28
FP_PWR_LED_N
27
GND
26
FP_LED_STATUS_GREEN_N
25
SMB_CHAS_SENSOR_STBY_LVC3_CLK
24
FP_LED_STATUS_AMBER_N
23
SMB_CHAS_SENSOR_STBY_LVC3_DATA
22
FP_Activity_LED_N
21
GND
20
FP_HDD_ACT_LED_N
19
SMB_IPMB_5VSTBY_CLK
18
GND
17
SMB_IPMB_5VSTBY_DATA
16
USB2_FP_DN
15
GND
Revision 1.34
Technical Product Specification
Connector and Header
Pin
14
USB2_FP_DP
Signal
Pin
13
Spare
Signal
12
GND
11
FM_PS_ALL_NODE_OFF
10
SATA6G_P4_RX_DP
9
FM_NODE_PRESENT_N (GND)
8
SATA6G_P4_RX_DN
7
GND
6
GND
5
SATA6G_P4_TX_DP
4
FM_USB_OC_FP_N
3
SATA6G_P4_TX_DN
2
P5V Aux
1
P5V Aux
Combined system BIOS and the Integrated BMC support provide the functionality of the
various supported control panel buttons and LEDs. The following sections describe the
supported functionality of each control panel feature.
6.3.1 Power Button
The BIOS supports a front control panel power button. Pressing the power button initiates a
request that the Integrated BMC forwards to the ACPI power state machines in the chipset. It is
monitored by the Integrated BMC and does not directly control power on the power supply.

Power Button — Off to On
The Integrated BMC monitors the power button and the wake-up event signals from
the chipset. A transition from either source results in the Integrated BMC starting the
power-up sequence. Since the processors are not executing, the BIOS does not
participate in this sequence. The hardware receives the power good and reset signals
from the Integrated BMC and then transitions to an ON state.

Power Button — On to Off (operating system absent)
The System Control Interrupt (SCI) is masked. The BIOS sets up the power button
event to generate an SMI and checks the power button status bit in the ACPI hardware
registers when an SMI occurs. If the status bit is set, the BIOS sets the ACPI power state
of the machine in the chipset to the OFF state. The Integrated BMC monitors power
state signals from the chipset and de-asserts PS_PWR_ON to the power supply. As a
safety mechanism, if the BIOS fails to service the request, the Integrated BMC
automatically powers off the system in four to five seconds.

Power Button — On to Off (operating system present)
If an ACPI operating system is running, pressing the power button switch generates a
request through SCI to the operating system to shut down the system. The operating
system retains control of the system and the operating system policy determines the
sleep state into which the system transitions, if any. Otherwise, the BIOS turns off the
system.
The tables below list the connector pin definitions on the bridge board.
Table 21. SATA DOM Connector Pin-out
Pin
Revision 1.34
Signal Description
65
Connector and Header
Technical Product Specification
1
GND
2
SATA_TX_P
3
SATA_TX_N
4
GND
5
SATA_RX_N
6
SATA_RX_P
7
P5V
Table 22. USB 2.0 Type-A Connector Pin-out
1
Pin
Signal Description
P5V_USB
2
USB2_P0N
3
USB2_P0P
4
GND
Table 23. 5V_AUX Power Connector Pin-out
Pin
Signal Description
1
GND
2
P5V
6.4 I/O Connectors
6.4.1 PCI Express* Connectors
The Intel® Server Board S2600KPR uses three PCI Express* slots physically with different
pin-out definition. Each riser slot has dedicated usage and cannot be used for normal PCIe
based add-in card.

Riser slot 1: Provide PCIe x16 to Riser. (Using standard 164-pin connector)

Riser slot 2: Provide PCIe x24 to Riser, or x8 to Intel® I/O Expansion Module. (Using 200pin HSEC8 Connector)

Riser slot 3: Provide PCIe x24 to Riser. (Using 200-pin HSEC8 Connector)
The PCIe bus segment usage from the processors is listed as below.
Table 24. CPU1 and CPU2 PCIe Bus Connectivity
66
CPU
CPU1
Port
DMI2
IOU
IOU2
Width
x4
Reserved for DMI2
Connection
CPU1
PE1
IOU2
X8
FDR IB (if depop, combine with riser 2)
CPU1
PE2
IOU0
x16
Riser 1
Revision 1.34
Technical Product Specification
Connector and Header
CPU1
PE3
IOU1
X24
Riser 2 (Depoped IB x8 to IOM on Riser)
CPU2
DMI2
IOU2
x4
Reserved for DMI2
CPU2
PE1
IOU2
x8
Riser 3
CPU2
PE2
IOU0
x16
Unused
CPU2
PE3
IOU1
X24
Riser 3 +IOU2
The pin-outs for the slots are shown in the following tables.
Table 25. PCI Express* x16 Riser Slot 1 Connector
Pin
B1
12V
Pin Name
Pin
A1
12V
Pin Name
B2
12V
A2
12V
B3
12V
A3
12V
B4
12V
A4
SMDATA
B5
SMCLK
A5
3.3VAUX
B6
3.3VAUX
A6
Spare
B7
GND
A7
Spare
B8
Spare
A8
Spare
B9
Spare
A9
Spare
B10
Spare
A10
Spare
B11
Spare
A11
Spare
KEY
Revision 1.34
B12
THRTL_N
A12
Spare
B13
Spare
A13
GND
B14
GND
A14
PERST#
B15
Spare
A15
WAKE#
B16
Spare
A16
GND
B17
GND
A17
REFCLK+
B18
PETxP0
A18
REFCLK-
B19
PETxN0
A19
GND
B20
GND
A20
PERxP0
B21
GND
A21
PERxN0
B22
PETxP1
A22
GND
B23
PETxN1
A23
GND
B24
GND
A24
PERxP1
B25
GND
A25
PERxN1
B26
PETxP2
A26
GND
B27
PETxN2
A27
GND
B28
GND
A28
PERxP2
B29
GND
A29
PERxN2
B30
PETxP3
A30
GND
67
Connector and Header
68
Technical Product Specification
Pin
B31
Pin Name
PETxN3
Pin
A31
GND
Pin Name
B32
GND
A32
PERxP3
B33
GND
A33
PERxN3
B34
PETxP4
A34
GND
B35
PETxN4
A35
GND
B36
GND
A36
PERxP4
B37
GND
A37
PERxN4
B38
PETxP5
A38
GND
B39
PETxN5
A39
GND
B40
GND
A40
PERxP5
B41
GND
A41
PERxN5
B42
PETxP6
A42
GND
B43
PETxN6
A43
GND
B44
GND
A44
PERxP6
B45
GND
A45
PERxN6
B46
PETxP7
A46
GND
B47
PETxN7
A47
GND
B48
GND
A48
PERxP7
B49
GND
A49
PERxN7
B50
PETxP8
A50
GND
B51
PETxN8
A51
GND
B52
GND
A52
PERxP8
B53
GND
A53
PERxN8
B54
PETxP9
A54
GND
B55
PETxN9
A55
GND
B56
GND
A56
PERxP9
B57
GND
A57
PERxN9
B58
PETxP10
A58
GND
B59
PETxN10
A59
GND
B60
GND
A60
PERxP10
B61
GND
A61
PERxN10
B62
PETxP11
A62
GND
B63
PETxN11
A63
GND
B64
GND
A64
PERxP11
B65
GND
A65
PERxN11
B66
PETxP12
A66
GND
B67
PETxN12
A67
GND
B68
GND
A68
PERxP12
B69
GND
A69
PERxN12
B70
PETxP13
A70
GND
B71
PETxN13
A71
GND
B72
GND
A72
PERxP13
Revision 1.34
Technical Product Specification
Connector and Header
Pin
B73
GND
Pin Name
Pin
A73
Pin Name
PERxN13
B74
PETxP14
A74
GND
B75
PETxN14
A75
GND
B76
GND
A76
PERxP14
B77
REFCLK+
A77
PERxN14
B78
REFCLK-
A78
GND
B79
GND
A79
PERxP15
B80
PETxP15
A80
PERxN15
B81
PETxN15
A81
GND
B82
GND
A82
Riser_ID0
Table 26. PCI Express* x24 Riser Slot 2 Connector
Pin
1
Pin Name
FM_RISER_ID1
3
GND
5
PERxP0
7
PERxN0
9
GND
11
PERxP1
13
PERxN1
15
GND
17
PERxP2
19
PERxN2
21
GND
23
PERxP3
25
PERxN3
27
GND
29
PERxP4
31
PERxN4
33
GND
35
PERxP5
37
PERxN5
39
GND
41
PERxP6
43
PERxN6
45
GND
47
PERxP7
49
PERxN7
51
GND
53
PERxP7 (IB)
Revision 1.34
Description
(See Table 28)
Pin
Pin Name
Description
2
GND
4
PETxP0
Tx Lane 0+
Rx Lane 0+
6
PETxN0
Tx Lane 0-
Rx Lane 0-
8
GND
10
PETxP1
Tx Lane 1+
Rx Lane 1+
12
PETxN1
Tx Lane 1-
Rx Lane 1-
14
GND
16
PETxP2
Tx Lane 2+
Rx Lane 2+
18
PETxN2
Tx Lane 2-
Rx Lane 2-
20
GND
22
PETxP3
Tx Lane 3+
Rx Lane 3+
24
PETxN3
Tx Lane 3-
Rx Lane 3-
26
GND
28
PETxP4
Tx Lane 4+
Rx Lane 4+
30
PETxN4
Tx Lane 4-
Rx Lane 4-
32
GND
34
PETxP5
Tx Lane 5+
Rx Lane 5+
36
PETxN5
Tx Lane 5-
Rx Lane 5-
38
GND
40
PETxP6
Tx Lane 6+
Rx Lane 6+
42
PETxN6
Tx Lane 6-
Rx Lane 6-
44
GND
46
PETxP7
Tx Lane 7+
Rx Lane 7+
48
PETxN7
Tx Lane 7-
Rx Lane 7-
50
GND
52
PETxP7 (IB)
Tx Lane 7+ (IB)
54
PETxN7 (IB)
Tx Lane 7- (IB)
Rx Lane 7+ (IB)
69
Connector and Header
Technical Product Specification
Pin
55
Pin Name
PERxN7 (IB)
Description
Rx Lane 7- (IB)
57
GND
59
PERxP6 (IB)
Rx Lane 6+ (IB)
61
PERxN6 (IB)
Rx Lane 6- (IB)
63
GND
Pin
56
GND
Pin Name
Description
58
PETxP6 (IB)
Tx Lane 6+ (IB)
60
PETxN6 (IB)
Tx Lane 6- (IB)
62
GND
64
GND
KEY
65
GND
66
GND
67
GND
68
PETxP5 (IB)
Tx Lane 5+ (IB)
69
PERxP5 (IB)
Rx Lane 5+ (IB)
70
PETxN5 (IB)
Tx Lane 5- (IB)
71
PERxN5 (IB)
Rx Lane 5- (IB)
72
GND
73
GND
74
PETxP4 (IB)
Tx Lane 4+ (IB)
75
PERxP4 (IB)
Rx Lane 4+ (IB)
76
PETxN4 (IB)
Tx Lane 4- (IB)
77
PERxN4 (IB)
Rx Lane 4- (IB)
78
GND
79
GND
80
PETxP3 (IB)
Tx Lane 3+ (IB)
81
PERxP3 (IB)
Rx Lane 3+ (IB)
82
PETxN3 (IB)
Tx Lane 3- (IB)
83
PERxN3 (IB)
Rx Lane 3- (IB)
84
GND
85
GND
86
PETxP2 (IB)
Tx Lane 2+ (IB)
87
PERxP2 (IB)
Rx Lane 2+ (IB)
88
PETxN2 (IB)
Tx Lane 2- (IB)
89
PERxN2 (IB)
Rx Lane 2- (IB)
90
GND
91
GND
92
PETxP1 (IB)
Tx Lane 1+ (IB)
93
PERxP1 (IB)
Rx Lane 1+ (IB)
94
PETxN1 (IB)
Tx Lane 1- (IB)
95
PERxN1 (IB)
Rx Lane 1- (IB)
96
GND
97
GND
98
PETxP0 (IB)
Tx Lane 0+ (IB)
99
PERxP0 (IB)
Rx Lane 0+ (IB)
100
PETxN0 (IB)
Tx Lane 0- (IB)
101
PERxN0 (IB)
Rx Lane 0- (IB)
102
GND
103
GND
104
PETxP8
Tx Lane 8+
105
PERxP8
Rx Lane 8+
106
PETxN8
Tx Lane 8-
107
PERxN8
Rx Lane 8-
108
GND
109
GND
110
PETxP9
Tx Lane 9+
111
PERxP9
Rx Lane 9+
112
PETxN9
Tx Lane 9-
113
PERxN9
Rx Lane 9-
114
GND
115
GND
116
PETxP10
Tx Lane 10+
117
PERxP10
Rx Lane 10+
118
PETxN10
Tx Lane 10-
119
PERxN10
Rx Lane 10-
120
GND
121
GND
122
PETxP11
Tx Lane 11+
123
PERxP11
Rx Lane 11+
124
PETxN11
Tx Lane 11-
125
PERxN11
Rx Lane 11-
126
GND
127
GND
128
PETxP12
Tx Lane 12+
129
PERxP12
Rx Lane 12+
130
PETxN12
Tx Lane 12-
131
PERxN12
Rx Lane 12-
132
GND
133
GND
134
PETxP13
Tx Lane 13+
135
PERxP13
136
PETxN13
Tx Lane 13-
70
Rx Lane 13+
Revision 1.34
Technical Product Specification
Pin
137
Pin Name
PERxN13
Pin
138
GND
139
GND
141
PERxP14
Rx Lane 14+
140
PETxP14
Tx Lane 14+
142
PETxN14
Tx Lane 14-
143
PERxN14
Rx Lane 14-
144
GND
145
GND
146
PETxP15
Tx Lane 15+
147
PERxP15
Rx Lane 15+
148
PETxN15
Tx Lane 15-
149
PERxN15
151
GND
Rx Lane 15-
150
GND
152
REFCLK1-
Clock pair 1
153
REFCLK0-
Clock pair 0
154
REFCLK1+
Clock pair 1
155
REFCLK0+
Clock pair 0
156
GND
157
GND
159
REFCLK2-
Clock pair 2
158
PCIE_WAKE#
160
PCIE_RST#
161
REFCLK2+
Clock pair 2
162
GND
163
GND
164
GPU_NODE_ON
165
SMB_DATA_HOST
SMB_HOST_3V3/V4_D
ATA
166
RSVD
167
SMB_CLK_HOST
SMB_HOST_3V3/V4_C
LK
168
RSVD
169
GND
170
THROTTLE_N
171
FAN_BMC_TACH11
FAN_BMC_TACH11_R
172
GND
173
FAN_BMC_TACH10
FAN_BMC_TACH10_R
174
BMC_MIC_MUX_RST_N
175
FAN_BMC_TACH9
FAN_BMC_TACH9_R
176
RSVD
177
FAN_BMC_TACH8
FAN_BMC_TACH8_R
178
RSVD
179
FAN_BMC_TACH7
FAN_BMC_TACH7_R
180
FAN_PWM1_OUT
181
FAN_BMC_TACH6
FAN_BMC_TACH6_R
182
GND
183
LED_RIOM_ACT_N
184
P3V3_AUX
185
IOM_PRESENT_N
186
SMB_CLK
187
P5V_AUX
188
GND
189
SMB_DATA
190
RSVD
191
GND
192
RSVD
193
PWRGD_GPU
194
GND
195
GND
196
P12V
197
P12V
198
P12V
199
P12V
200
P12V
Revision 1.34
Description
Rx Lane 13-
Connector and Header
IOM_PRESENT_N
PCI_SLOT2_DATA
Pin Name
Description
THROTTLE_RISER2_N
for SMB mux
71
Connector and Header
Technical Product Specification
Table 27. PCI Express* x24 Riser Slot 3 Connector
1
Pin
Pin Name
RISER_ID2
3
5
7
9
GND
PERxP7
PERxN7
GND
11
13
15
17
19
21
23
25
27
29
31
33
35
37
39
41
43
45
47
49
51
53
55
57
59
61
63
PERxP6
PERxN6
GND
PERxP5
PERxN5
GND
PERxP4
PERxN4
GND
PERxP3
PERxN3
GND
PERxP2
PERxN2
GND
PERxP1
PERxN1
GND
PERxP0
PERxN0
GND
PERxP15
PERxN15
GND
PERxP14
PERxN14
GND
65
67
69
71
73
75
77
79
GND
PERxP13
PERxN13
GND
GND
PERxP12
PERxN12
GND
81
83
85
87
PERxP11
PERxN11
GND
PERxP10
72
Description
Pin
Pin Name
Description
(See Table 28)
2
GND
Rx Lane 7+
Rx Lane 7-
4
6
8
10
PETxP7
PETxN7
GND
PETxP6
Tx Lane 7+
Tx Lane 7-
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
44
46
48
50
52
54
56
58
60
62
64
KEY
66
68
70
72
74
76
78
80
PETxN6
GND
PETxP5
PETxN5
GND
PETxP4
PETxN4
GND
PETxP3
PETxN3
GND
PETxP2
PETxN2
GND
PETxP1
PETxN1
GND
PETxP0
PETxN0
GND
PETxP15
PETxN15
GND
PETxP14
PETxN14
GND
RSVD
Tx Lane 6-
82
84
86
88
PETxN11
GND
PETxP10
PETxN10
Rx Lane 6+
Rx Lane 6Rx Lane 5+
Rx Lane 5Rx Lane 4+
Rx Lane 4Rx Lane 3+
Rx Lane 3Rx Lane 2+
Rx Lane 2Rx Lane 1+
Rx Lane 1Rx Lane 0+
Rx Lane 0Rx Lane 15+
Rx Lane 15Rx Lane 14+
Rx Lane 14-
Rx Lane 13+
Rx Lane 13-
Rx Lane 12+
Rx Lane 12Rx Lane 11+
Rx Lane 11Rx Lane 10+
GND
PETxP13
PETxN13
GND
PETxP12
PETxN12
GND
PETxP11
Tx Lane 6+
Tx Lane 5+
Tx Lane 5Tx Lane 4+
Tx Lane 4Tx Lane 3+
Tx Lane 3Tx Lane 2+
Tx Lane 2Tx Lane 1+
Tx Lane 1Tx Lane 0+
Tx Lane 0Tx Lane 15+
Tx Lane 15Tx Lane 14+
Tx Lane 14-
Tx Lane 13+
Tx Lane 13Tx Lane 12+
Tx Lane 12Tx Lane 11+
Tx Lane 11Tx Lane 10+
Tx Lane 10-
Revision 1.34
Technical Product Specification
Pin
89
91
93
95
97
99
101
103
105
107
109
111
113
115
117
119
121
123
125
127
129
131
133
Pin Name
PERxN10
GND
PERxP9
PERxN9
GND
PERxP8
PERxN8
GND
PERxP7
PERxN7
GND
PERxP6
PERxN6
GND
PERxP5
PERxN5
GND
PERxP4
PERxN4
GND
PERxP3
PERxN3
GND
Description
Rx Lane 10-
135
137
139
141
PERxP2
PERxN2
GND
PERxP1
Rx Lane 2+
Rx Lane 2-
143
145
147
149
151
153
155
157
159
161
163
165
167
169
171
173
175
177
179
181
PERxN1
GND
PERxP0
PERxN0
GND
REFCLK0REFCLK0+
GND
REFCLK2REFCLK2+
GND
RSVD
RSVD
GND
RSVD
GND
RSVD
RSVD
RSVD
RSVD
Rx Lane 1-
Revision 1.34
Rx Lane 9+
Rx Lane 9Rx Lane 8+
Rx Lane 8Rx Lane 7+
Rx Lane 7Rx Lane 6+
Rx Lane 6Rx Lane 5+
Rx Lane 5Rx Lane 4+
Rx Lane 4Rx Lane 3+
Rx Lane 3-
Rx Lane 1+
Rx Lane 0+
Rx Lane 0Clock pair 0
Clock pair 0
Clock pair 2 (SAS)
Clock pair 2 (SAS)
Connector and Header
Pin
90
92
94
96
98
100
102
104
106
108
110
112
114
116
118
120
122
124
126
128
130
132
134
Pin Name
GND
PETxP9
PETxN9
GND
PETxP8
PETxN8
GND
PETxP7
PETxN7
GND
PETxP6
PETxN6
GND
PETxP5
PETxN5
GND
PETxP4
PETxN4
GND
PETxP3
PETxN3
GND
PETxP2
136
138
140
142
PETxN2
GND
PETxP1
PETxN1
144
146
148
150
152
154
156
158
160
162
164
166
168
170
172
174
176
178
180
182
GND
PETxP0
PETxN0
GND
REFCLK1REFCLK1+
GND
PCIE_WAKE#
PCIE_RST#
GND
RSVD
RSVD
RSVD
THROTTLE_N
GND
RSVD
RSVD
RSVD
RSVD
GND
Description
Tx Lane 9+
Tx Lane 9Tx Lane 8+
Tx Lane 8Tx Lane 7+
Tx Lane 7Tx Lane 6+
Tx Lane 6Tx Lane 5+
Tx Lane 5Tx Lane 4+
Tx Lane 4Tx Lane 3+
Tx Lane 3Tx Lane 2+
Tx Lane 2Tx Lane 1+
Tx Lane 1Tx Lane 0+
Tx Lane 0Clock pair 1
Clock pair 1
THROTTLE_RISER3_N
73
Connector and Header
Pin
183
185
187
189
191
193
195
197
199
Technical Product Specification
Pin Name
RSVD
SAS_PRESENT_N
RSVD
SMB_DATA
GND
RSVD
GND
P12V
P12V
Description
Pin
184
186
188
190
192
194
196
198
200
SAS_PRESENT_N
SMB_PCI_SLOT3_DATA
Pin Name
P3V3/V4_AUX
SMB_CLK
GND
RSVD
RSVD
GND
P12V
P12V
P12V
Description
SMB_PCI_SLOT3_CLK
Table 28. PCI Express* Riser ID Assignment
CPU1
Description
Riser 1 1x16
Riser ID (0)
1
Riser 1 2x8
0
CPU2
Riser ID (2)
Riser ID (1)
Riser 2 1x16 + 1x8 (S2600KPR only)
1
Riser 2 2x8 + 1x8 (S2600KPR only)
0
Riser 3 1x16 + 1x8
1
Riser 3 2x8 + 1x8
0
Note: PCIe bifurcation setting in the BIOS will override riser slot pin setting.
Table 29. PCI Express* Clock Source by Slot
PCIE SLOT RISER
SLOT 1
PCI Express Clocks Source according Riser's lane
X16 PCIE PIN
X8 (lane 0~7) PCIE PIN
X8 (lane 8~15) PCIE PIN
PIN A17/A18
PIN B77/B78
PIN A17/A18
SLOT 2
PIN 153/155
PIN 152/154
PIN 153/155
SLOT 3
PIN 153/155
PIN 152/154
PIN 153/155
6.4.2 VGA Connector
The following table details the pin-out definition of the external VGA connector.
Table 30. VGA External Video Connector
Pin
74
1
Signal Name
V_IO_R_CONN
Description
Red (analog color signal R)
2
V_IO_G_CONN
Green (analog color signal G)
3
V_IO_B_CONN
Blue (analog color signal B)
4
NC
No connection
5
GND
Ground
6
GND
Ground
Revision 1.34
Technical Product Specification
Pin
Connector and Header
Signal Name
Description
7
GND
Ground
8
GND
Ground
9
P5V
No fuse protection
10
GND
Ground
11
NC
No connection
12
V_IO_DDCDAT
DDCDAT
13
V_IO_HSYNC_CONN
HSYNC (horizontal sync)
14
V_IO_VSYNC_CONN
VSYNC (vertical sync)
15
V_IO_DDCCLK
DDCCLK
6.4.3 NIC Connectors
The server board provides three independent RJ-45 connectors on the back edge of the
board. The pin-outs for NIC connectors are identical and are defined in the following table.
Table 31. RJ-45 10/100/1000 NIC Connector
1
Pin
Signal Name
LED_NIC_LINK0_100_N
2
LED_NIC_LINK0_1000_R_N
3
NIC_0_0_DP
4
NIC_0_0_DN
5
NIC_0_1_DP
6
NIC_0_1_DN
7
NIC_CT1
8
NIC_CT2
9
NIC_0_2_DP
10
NIC_0_2_DN
11
NIC_0_3_DP
12
NIC_0_3_DN
13
LED_NIC_LINK0_LNKUP_N
14
LED_NIC_LINK0_ACT_R_N
6.4.4 SATA Connectors
The server board provides five SATA port connectors from SATA_0 to SATA_3 ports and
SATA DOM support on board. Additional four SATA ports are provided through the bridge
board.
The pin configuration for each connector is identical and defined in the following table.
Revision 1.34
75
Connector and Header
Technical Product Specification
Table 32. SATA Connector
Pin
Signal Name
Description
1
GND
Ground
2
SATA_TX_P
Positive side of transmit differential pair
3
SATA_TX_N
Negative side of transmit differential pair
4
GND
Ground
5
SATA_RX_N
Negative side of receive differential pair
6
SATA_RX_P
Positive side of receive differential pair
7
P5V_SATA/GND
+5V for DOM (J6D1) or Ground for SATA signals
Note: SATA DOM requiring external power cannot be used with SATADOM port on board.
6.4.5 SATA SGPIO Connectors
The server board provides one SATA SGPIO connector.
The pin configuration for the connector is defined in the following table.
Table 33. SATA SGPIO Connector
Pin
1
Description
SGPIO_SSATA_CLOCK
2
SGPIO_SSATA_LOAD
3
GND
4
SGPIO_SSATA_DATAOUT0
5
SGPIO_SSATA_DATAOUT1
6.4.6 Hard Drive Activity LED Header
Table 34. SATA HDD Activity LED Header
Pin
1
2
Description
LED_HD_ACTIVE_N
NC
6.4.7 Intel® RAID C600 Upgrade Key Connector
The server board provides one Intel® RAID C600 Upgrade Key Connector (storage upgrade
key) connector on board.
The Intel® RAID C600 Upgrade Key is a small PCB board that has up to two security EEPROMs
that are read by the system ME to enable different versions of LSI* RAID 5 software stack.
The pin configuration of connector is identical and defined in the following table.
76
Revision 1.34
Technical Product Specification
Connector and Header
Table 35. Storage Upgrade Key Connector
Pin
Signal Description
1
GND
2
PU_KEY
3
GND
4
PCH_SATA_RAID_KEY
6.4.8 Serial Port Connectors
The server board provides one internal 9-pin serial type-A header. The following tables define
the pin-outs.
Table 36. Internal 9-pin Serial A
1
Pin
Signal Name
SPA_DCD
Pin
2
Signal Name
SPA_DSR
3
SPA_SIN_N
4
SPA_RTS
5
SPA_SOUT_N
6
SPA_CTS
7
SPA_DTR
8
SPA_RI
9
GND
10
KEY
6.4.9 USB Connectors
The following table details the pin-out of the external stack USB port connectors found on the
back edge of the server board.
Table 37. External USB port Connector
Pin
1
Signal Name
+5V
USB Power
Description
2
USB_N
Differential data line paired with DATAH0
3
USB_P
Differential date line paired with DATAL0
4
GND
Ground
One 2x5 connector on the server board provides an option to support two additional internal
USB ports. The pin-out is detailed in the following table.
Table 38. Internal USB Connector
Pin
Revision 1.34
1
Signal Name
+5V
2
Pin
+5V
Signal Name
3
USB_N
4
USB_N
5
USB_P
6
USB_P
7
GND
8
GND
77
Connector and Header
Technical Product Specification
Pin
Signal Name
Key
9
Pin
10
Signal Name
NC
6.4.10 QSFP+ for InfiniBand*
The following table details the pin-out of the QSFP+ connector found on the back edge of the
server board. This port is available only on board SKU S2600KPF.
Table 39. QSFP+ Connector
Pin
19
GND
Signal
Pin
38
GND
Signal
18
IB_RX0_DN0
37
IB_RX0_DN1
17
IB_RX0_DP0
36
IB_RX0_DP1
16
GND
35
GND
15
IB_RX0_DN2
34
IB_RX0_DN3
14
IB_RX0_DP2
33
IB_RX0_DP3
13
GND
32
GND
12
SMB_IB_QSFP0_DATA
31
IB_MODPRSL_PORT1_N
11
SMB_IB_QSFP0_CLK
30
IB_INT_PORT1
10
P3V3/V4_RX_PORT0
29
P3V3/V4_TX_PORT0
9
IB_RESET_PORT1
28
P3V3/V4_PORT0
8
IB_MODSEIL_PORT1_N
27
PD_QSFP0_LPMODE
7
GND
26
GND
6
IB_TX0_DP3
25
IB_TX0_DP2
5
IB_TX0_DN3
24
IB_TX0_DN2
4
GND
23
GND
3
IB_TX0_DP1
22
IB_TX0_DP0
2
IB_TX0_DN1
21
IB_TX0_DN0
1
GND
20
GND
6.4.11 UART Header
The following table details the pin-out of the UART header. This header is only available on
12G SAS bridge board.
Table 40. UART Header
Pin
78
1
Signal
SP0_SAS_TX_P1V8
2
GND
3
SP0_SAS_RX_P1V8
4
P1V8
Revision 1.34
Technical Product Specification
Connector and Header
6.5 Fan Headers
6.5.1 FAN Control Cable Connector
To facilitate the connection of 3 double rotor fans, a 14 pin header is provided, all fans will
share a PWM. Both rotor tachs can be monitored.
Table 41. Baseboard Fan Connector
1
Pin
Signal Name
FAN_PWM_OUT
2
Pin
Key
Signal Name
3
FAN_BMC_TACH0
4
FAN_BMC_TACH1
5
FAN_BMC_TACH2
6
FAN_BMC_TACH3
7
FAN_BMC_TACH4
8
FAN_BMC_TACH5
9
PS_HOTSWAP_EN
10
GND
11
SMB_HOST_3V3/V4_CLK
12
SMB_HOST_3V3/V4_DATA
13
NODE_ADR0(GND)
14
PWRGD_PS_PWROK
The SMBus* is used to connect to the hot swap controller that provides inrush current
protection and can measure the power being used by the compute module. The NODE_ON
signal is used to turn on the hot swap controller. Note that the polarity is correct as the
ADM1275 controller uses a high true enable signal. When the compute module is turned off,
the fans will continue to rotate at a preset rate; this rate is selected by Intel and preset by the
Fan manufacturer. This is done to stop air recirculation between compute modules. When
docking the board to a live 12V rail, the fans could spin up immediately; they may be required
to phase their connection to power to minimize the inrush current. Bench testing of the fans
should determine if this is necessary.
6.5.2 Discrete System FAN Connector
To support the 3rd party chassis, three discrete system fan connectors are provided on
baseboard. They are used for connecting FANs with tach meters directly.
Table 42. Baseboard Fan Connector
Pin
1
Fan 1
Signal Description
GND
Pin
1
Fan 2
Signal Description
GND
Pin
1
Fan 3
Signal Description
GND
2
P12V
2
P12V
2
P12V
3
BMC_TACH0_R
3
BMC_TACH2_R
3
BMC_TACH4_R
4
PWM0
4
PWM0
4
PWM0
5
GND
5
GND
5
GND
6
P12V
6
P12V
6
P12V
7
BMC_TACH1_R
7
BMC_TACH3_R
7
BMC_TACH5_R
8
PWM0
8
PWM0
8
PWM0
Revision 1.34
79
Connector and Header
Technical Product Specification
6.6 Power Docking Board Connectors
The table below lists the connector type and pin definition on the power docking board.
Table 43. Main Power Input Connector
Pin
Signal Description
Lower Blade (Circuit 1)
Pin
Signal Description
1
GND
2
GND
3
GND
4
GND
5
GND
6
GND
Upper Blade (Circuit 2)
7
P12V
8
P12V
9
P12V
10
P12V
11
P12V
12
P12V
Table 44. Fan Control Signal Connector
1
Pin
Signal Description
PWM1
2
Pin
Signal Description
Reserved
3
Tach0
4
Tach1
5
Tach2
6
Tach3
7
Tach4
8
Tach5
9
NODE_ON
10
GND
11
SMBUS_R4 CLK
12
SMBUS_R4 DAT
13
NODE_ADR0
14
NODE_PWRGD
Table 45. Compute Module Fan Connector
Pin
Signal Description
1
GND
2
P12V
3
TACH0
4
PWM1
5
GND
6
P12V
7
TACH1
8
PWM1
Table 46. Main Power Output Connector
Pin
1
80
Signal Description
GND
Pin
7
Signal Description
P12V_HS
Revision 1.34
Technical Product Specification
Pin
Connector and Header
2
Signal Description
GND
8
Pin
Signal Description
P12V_HS
3
GND
9
P12V_HS
4
GND
10
P12V_HS
5
GND
11
P12V_HS
6
GND
12
P12V_HS
6.7 Breakout Board Connector
Table 47. Miscellaneous Signal Connector
Pin
Revision 1.34
1
Signal Description
SMB_CHAS_SENSOR_STBY_LVC3_DATA
2
GND
3
SMB_CHAS_SENSOR_STBY_LVC3_CLK
4
P3V3_AUX
5
FP_LED_STATUS_AMBER_R_N
6
FP_LED_STATUS_GREEN_R_N
7
FP_NMI_BTN_R_N
81
Configuration Jumpers
7
Technical Product Specification
Configuration Jumpers
The following table provides a summary and description of configuration, test, and debug
jumpers. The server board has several 3-pin jumper blocks that can be used. Pin 1 on each
jumper block can be identified by the following symbol on the silkscreen: ▼
Figure 41. Jumper Location
Table 48. Jumper Modes Selection
Jumper Name
J6B4: PS All Node off
J6B6: BMC Force
Update
J6B7: BIOS Default
J6B8: Password Clear
J6B9: BIOS Recovery
Mode
J5D2: ME Force
Update
82
Jumper Position
1-2
2-3
1-2
2-3
1-2
2-3
1-2
2-3
1-2
2-3
1-2
2-3
Mode of Operation
Normal
PS all node off
Normal
Update
Normal
Clear BIOS Settings
Normal
Clear Password
Normal
Recovery
Normal
Update
Note
Normal mode
Enable integration with 3rd Chassis/PS
Normal mode
BMC in force update mode
Normal mode
BIOS settings are reset to factory default
Normal mode, password in protection
BIOS password is cleared
Normal mode
BIOS in recovery mode
Normal mode
ME in force update mode
Revision 1.34
Technical Product Specification
Configuration Jumpers
7.1 PS All Node off (J6B4)
The PS All Node off jumper (J6B4) on the Intel® Server Board S2600KP product Family
enables integration of a third party Chassis and/or Power Supply for board-only SKUs. The
jumper has to stay in 2-3 in order to use this feature.
Table 49. PS All Node off (J6B4)
Jumper Position
1-2
Mode of Operation
Normal
Normal operation
Note
2-3
PS All Node off
Enable integration with 3rd Chassis/PS
7.2 BMC Force Update (J6B6)
When performing a standard BMC firmware update procedure, the update utility places the
BMC into an update mode, allowing the firmware to load safely onto the flash device. In the
unlikely event the BMC firmware update process fails due to the BMC not being in the proper
update state, the server board provides a BMC Force Update jumper (J6B1) which will force
the BMC into the proper update state. The following procedure should be followed in the
event the standard BMC firmware update process fails.
Table 50. Force Integrated BMC Update Jumper (J6B6)
Jumper Position
1-2
Mode of Operation
Normal
Normal operation
Note
2-3
Update
BMC in force update mode
Steps to perform Force BMC Update:
1. Plug out the compute module.
2. Remove the air duct. See the Service Guide for instructions.
3. Move the jumper (J6B6) from the default operating position (covering pins 1 and 2) to
the enabled position (covering pins 2 and 3).
4. Restore the air duct to the compute module.
5. Insert the compute module back to the chassis.
6. Power on the compute module by pressing the power button on the front panel.
7. Perform the BMC firmware update procedure as documented in the Release Notes
included in the given BMC firmware update package. After successful completion of the
firmware update process, the firmware update utility may generate an error stating the
BMC is still in update mode.
8. Power down and plug out the compute module.
9. Remove the air duct.
Revision 1.34
83
Configuration Jumpers
Technical Product Specification
10. Move the jumper from the enabled position (covering pins 2 and 3) to the disabled
position (covering pins 1 and 2).
11. Restore the air duct to the compute module.
12. Plug in the compute module back to the chassis and power up the server.
Note: Normal BMC functionality is disabled with the Force BMC Update jumper set to the
enabled position. You should never run the server with the BMC Force Update jumper set in this
position. You should only use this jumper setting when the standard firmware update process
fails. This jumper should remain in the default/disabled position when the server is running
normally.
The server board has several 3-pin jumper blocks that can be used to configure, protect, or
recover specific features of the server board.
7.3 ME Force Update (J5D2)
When this 3-pin jumper is set, it manually puts the ME firmware in update mode, which
enables the user to update ME firmware code when necessary.
Table 51. Force ME Update Jumper (J5D2)
Jumper Position
1-2
Mode of Operation
Normal
Normal operation
Note
2-3
Update
ME in force update mode
Note: Normal ME functionality is disabled with the ME Force Update jumper set to the enabled
position. You should never run the server with the ME Force Update jumper set in this position.
You should only use this jumper setting when the standard firmware update process fails. This
jumper should remain in the default/disabled position when the server is running normally.
Steps to perform the Force ME Update:
84
1.
Plug out the compute module from the chassis.
2.
Remove the air duct. See the Service Guide for instructions.
3.
Move the jumper (J5D2) from the default operating position (covering pins 1 and 2) to
the enabled position (covering pins 2 and 3).
4.
Restore the air duct back to the compute module.
5.
Plug in the compute module back to the chassis.
6.
Perform the ME firmware update procedure as documented in the Release Notes file
that is included in the given system update package.
7.
After update process is done, plug out the compute module out of the chassis.
Revision 1.34
Technical Product Specification
Configuration Jumpers
8.
Remove the air duct.
9.
Move the jumper from the enabled position (covering pins 2 and 3) to the disabled
position (covering pins 1 and 2).
10. Restore the compute module back to the chassis.
7.4 Password Clear (J6B8)
The user sets this 3-pin jumper to clear the password.
Revision 1.34
85
Configuration Jumpers
Technical Product Specification
Table 52. Password Clear Jumper (J6B8)
Jumper Position
1-2
Mode of Operation
Normal
Note
Normal mode, password in protection
2-3
Clear Password
BIOS password is cleared
This jumper causes both the User password and the Administrator password to be cleared if
they were set. The operator should be aware that this creates a security gap until passwords
have been installed again.
Note: No method of resetting BIOS configuration settings to the default values will affect either
the Administrator or User passwords.
This is the only method by which the Administrator and User passwords can be cleared
unconditionally. Other than this jumper, passwords can only be set or cleared by changing
them explicitly in BIOS Setup or by similar means.
The recommended steps to clear the User and Administrator passwords are:
1. Plug out the compute module and remove the air duct.
2. Move the jumper from pins 1-2 to pins 2-3. It is necessary to leave the jumper in place
while rebooting the system in order to clear the passwords.
3. Installed the air duct and plug in and power up the compute module.
4. Boot into the BIOS Setup. Check the Error Manager tab for POST Error Codes:
5221 Passwords cleared by jumper
5224 Password clear jumper is set
5. Power down and plug out the compute module and remove the air duct again.
6. Restore the jumper from pins 2-3 to the normal setting of pins 1-2.
7. Installed the air duct and plug in and power up the compute module.
8. Strongly recommended: Boot into the BIOS Setup immediately, go to the Security tab
and set the Administrator and User passwords if you intend to use BIOS password
protection.
7.5 BIOS Recovery Mode (J6B9)
If a system is completely unable to boot successfully to an OS, hangs during POST, or even
hangs and fails to start executing POST, it may be necessary to perform a BIOS Recovery
procedure, which can replace a defective copy of the Primary BIOS.
The BIOS introduces three mechanisms to start the BIOS recovery process, which is called
Recovery Mode:

86
Recovery Mode Jumper – This jumper causes the BIOS to boot in Recovery Mode.
Revision 1.34
Technical Product Specification
Configuration Jumpers

The BootBlock detects partial BIOS update and automatically boots in Recovery Mode.

The BMC asserts Recovery Mode GPIO in case of partial BIOS update and FRB2 timeout.
Table 53. BIOS Recovery Mode Jumper (J6B9)
Jumper Position
1-2
Mode of Operation
Normal
Note
Normal mode
2-3
Recovery
BIOS in recovery mode
The BIOS Recovery takes place without any external media or Mass Storage device as it
utilizes the Backup BIOS inside the BIOS flash in Recovery Mode.
The Recovery procedure is included here for general reference. However, if in conflict, the
instructions in the BIOS Release Notes are the definitive version.
When Recovery Mode Jumper is set, the BIOS begins with a “Recovery Start” event logged to
the SEL, loads and boots with the Backup BIOS image inside the BIOS flash itself. This process
takes place before any video or console is available. The system boots up into the Shell
directly while a “Recovery Complete” SEL logged. An external media is required to store the
BIOS update package and steps are the same as the normal BIOS update procedures. After the
update is complete, there will be a message displayed stating that the “BIOS has been
updated successfully" indicating the BIOS update process is finished. The User should then
switch the recovery jumper back to normal operation and restart the system by performing a
power cycle.
If the BIOS detects partial BIOS update or the BMC asserts Recovery Mode GPIO, the BIOS will
boot up with Recovery Mode. The difference is that the BIOS boots up to the Error Manager
Page in the BIOS Setup utility. In the BIOS Setup utility, boot device, Shell or Linux for
example, could be selected to perform the BIOS update procedure under Shell or OS
environment.
Again, before starting to perform a Recovery Boot, be sure to check the BIOS Release Notes
and verify the Recovery procedure shown in the Release Notes.
The following steps demonstrate this recovery process:
1. Plug out the compute module and remove the air duct.
2. Move the jumper (J6B9) from the default operating position (covering pins 1 and 2) to
the BIOS Recovery position (covering pins 2 and 3).
3. Restore the air duct back to the compute module.
4. Plug in the compute module back to the chassis.
5. Power on the compute module.
Revision 1.34
87
Configuration Jumpers
Technical Product Specification
6. The BIOS will load and boot with the backup BIOS image without any video or display.
7. When the compute module boots into the EFI shell directly, the BIOS recovery is
successful.
8. Power off the compute module.
9. Plug out the compute module from the chassis.
10. Remove the air duct and put the jumper (J6B9) back to the normal position (covering
pins 1 and 2).
11. Restore the air duct and put the compute module back to the chassis.
12. A normal BIOS update can be performed if needed.
7.6 BIOS Default (J6B7)
Table 54. BIOS Default Jumper
Jumper Position
1-2
Mode of Operation
Normal
Normal mode
Note
2-3
Clear BIOS settings
BIOS settings are reset to factory default
This jumper causes the BIOS Setup settings to be reset to their default values. On previous
generations of server boards, this jumper has been referred to as “Clear CMOS”, or “Clear
NVRAM”. Setting this jumper according to the procedure below will clear all current contents
of NVRAM variable storage, and then load the BIOS default settings.
Note that this jumper does not reset Administrator or User passwords. In order to reset
passwords, the Password Clear jumper must be used.
The recommended steps to reset to the BIOS defaults are:
1. Plug out the compute module and remove the air duct.
2. Move the jumper from pins 1-2 to pins 2-3 momentarily. It is not necessary to leave the
jumper in place while rebooting.
3. Restore the jumper from pins 2-3 to the normal setting of pins 1-2.
4. Install the air duct and plug in the compute module, and power up.
5. Boot the system into Setup. Check the Error Manager tab, and you should see POST
Error Codes:
0012 System RTC date/time not set
5220 BIOS Settings reset to default settings
6. Go to the Setup Main tab, and set the System Date and System Time to the correct
current settings. Make any other changes that are required in Setup – for example, Boot
Order.
88
Revision 1.34
Technical Product Specification
Revision 1.34
Configuration Jumpers
89
Intel® Light-Guided Diagnostics
8
Technical Product Specification
Intel® Light-Guided Diagnostics
Intel® Server Board S2600KPR has several onboard diagnostic LEDs to assist in
troubleshooting board-level issues. This section provides a description of the location and
function of each LED on the server board.
8.1 Status LED
Note: The status LED state shows the state for the current, most severe fault. For example, if
there was a critical fault due to one source and a non-critical fault due to another source, the
status LED state would be solid on (the critical fault state).
The status LED is a bicolor LED. Green (status) shows a normal operation state or a degraded
operation. Amber (fault) shows the hardware state and overrides the green status.
The Integrated BMC-detected state and the state from the other controllers, such as the
SCSI/SATA hot-swap controller state, are included in the LED state. For fault states monitored
by the Integrated BMC sensors, the contribution to the LED state follows the associated sensor
state, with the priority going to the most critical state currently asserted.
When the server is powered down (transitions to the DC-off state or S5), the Integrated BMC is
still on standby power and retains the sensor and front panel status LED state established
prior to the power-down event.
The following table maps the server state to the LED state.
Figure 42. Status LED (E) and ID LED (D)
90
Revision 1.34
Technical Product Specification
Intel® Light-Guided Diagnostics
Table 55. Status LED State Definitions
Color
Off
Green
State
System is
not
operating
Solid on
Criticality
Not ready
Description
 System is powered off (AC and/or DC).
 System is in EuP Lot6 Off Mode.
 System is in S5 Soft-Off State.
Ok
Indicates that the System is running (in S0 State) and
its status is ‘Healthy’. The system is not exhibiting any
errors. AC power is present and BMC has booted and
manageability functionality is up and running.
After a BMC reset, and in conjuction with the Chassis
ID solid ON, the BMC is booting Linux*. Control has
been passed from BMC uBoot to BMC Linux* itself. It
will be in this state for ~10-~20 seconds
Green
~1 Hz blink
Degraded - system is
operating in a degraded state
although still functional, or
system is operating in a
redundant state but with an
impending failure warning
System degraded:
 Redundancy loss such as power-supply or fan.
Applies only if the associated platform sub-system
has redundancy capabilities.
 Fan warning or failure when the number of fully
operational fans is less than minimum number
needed to cool the system.
 Non-critical threshold crossed – Temperature
(including HSBP temp), voltage, input power to
power supply, output current for main power rail
from power supply and Processor Thermal Control
(Therm Ctrl) sensors.
 Power supply predictive failure occurred while
redundant power supply configuration was
present.
 Unable to use all of the installed memory (more
than 1 DIMM installed).
 Correctable Errors over a threshold and migrating
to a spare DIMM (memory sparing). This indicates
that the system no longer has spared DIMMs (a
redundancy lost condition). Corresponding DIMM
LED lit.
 In mirrored configuration, when memory mirroring
takes place and system loses memory redundancy.
 Battery failure.
 BMC executing in uBoot. (Indicated by Chassis ID
blinking at 3Hz). System in degraded state (no
manageability). BMC uBoot is running but has not
transferred control to BMC Linux*. Server will be in
this state 6-8 seconds after BMC reset while it
pulls the Linux* image into flash.
 BMC Watchdog has reset the BMC.
 Power Unit sensor offset for configuration error is
asserted.
 HDD HSC is off-line or degraded.
Revision 1.34
91
Intel® Light-Guided Diagnostics
Color
Amber
State
~1 Hz blink
Criticality
Non-critical - System is
operating in a degraded state
with an impending failure
warning, although still
functioning
Technical Product Specification
Description
Non-fatal alarm – system is likely to fail:
 Critical threshold crossed – Voltage, temperature
(including HSBP temp), input power to power
supply, output current for main power rail from
power supply and PROCHOT (Therm Ctrl) sensors.
 VRD Hot asserted.
 Minimum number of fans to cool the system not
present or failed
 Hard drive fault
 Power Unit Redundancy sensor – Insufficient
resources offset (indicates not enough power
supplies present)
 In non-sparing and non-mirroring mode if the
threshold of correctable errors is crossed within
the window
Amber
Solid on
Critical, non-recoverable –
System is halted
Fatal alarm – system has failed or shutdown:
 CPU CATERR signal asserted
 MSID mismatch detected (CATERR also asserts for
this case).
 CPU 1 is missing
 CPU Thermal Trip
 No power good – power fault
 DIMM failure when there is only 1 DIMM present
and hence no good memory present.
 Runtime memory uncorrectable error in nonredundant mode.
 DIMM Thermal Trip or equivalent
 SSB Thermal Trip or equivalent
 CPU ERR2 signal asserted
 BMC/Video memory test failed. (Chassis ID shows
blue/solid-on for this condition)
 Both uBoot BMC firmware images are bad. (Chassis
ID shows blue/solid-on for this condition)
 240VA fault
 Fatal Error in processor initialization:
o
Processor family not identical
o
Processor model not identical
o
Processor core/thread counts not identical
o
Processor cache size not identical
o
Unable to synchronize processor frequency
o
Unable to synchronize QPI link frequency
 Uncorrectable memory error in a non-redundant
mode
92
Revision 1.34
Technical Product Specification
Intel® Light-Guided Diagnostics
8.2 ID LED
The ID LED provides a visual indication of the server board or compute module being serviced.
The state of the ID LED is affected by the following:

Toggled by the ID button

Controlled by the Chassis Identify command (IPMI)
Table 56. ID LED
State
Identify active through button
LED State
Solid on
Identify active through command
~1 Hz blink
Off
Off
There is no precedence or lock-out mechanism for the control sources. When a new request
arrives, all previous requests are terminated. For example, if the ID LED is blinking and the
chassis ID button is pressed, then the ID LED changes to solid on. If the button is pressed
again with no intervening commands, the ID LED turns off.
8.3
BMC Boot/Reset Status LED Indicators
During the BMC boot or BMC reset process, the System Status LED and System ID LED are
used to indicate BMC boot process transitions and states. A BMC boot will occur when AC
power is first applied to the system. A BMC reset will occur after a BMC firmware update, upon
receiving a BMC cold reset command, and upon a BMC watchdog initiated reset. The following
table defines the LED states during the BMC Boot/Reset process.
Table 57. BMC Boot/Reset Status LED Indicators
BMC Boot/Reset State
Chassis
ID LED
Status
LED
Comment
BMC/Video memory test
failed
Solid
Blue
Solid
Amber
Non-recoverable condition. Contact your Intel
representative for information on replacing this
motherboard.
Both Universal Bootloader
(u-Boot) images bad
Blink
Blue 6
Hz
Solid
Amber
Non-recoverable condition. Contact your Intel
representative for information on replacing this
motherboard.
BMC in u-Boot
Blink
Blue 3
Hz
Blink
Green
1Hz
Blinking green indicates degraded state (no
manageability), blinking blue indicates u-Boot is running
but has not transferred control to BMC Linux. Server will
be in this state 6-8 seconds after BMC reset while it pulls
the Linux image into flash.
BMC Booting Linux
Solid
Blue
Solid
Green
Solid green with solid blue after an AC cycle/BMC reset,
indicates that the control has been passed from u-Boot to
BMC Linux itself. It will be in this state for ~10-~20
seconds.
Revision 1.34
93
Intel® Light-Guided Diagnostics
BMC Boot/Reset State
End of BMC boot/reset
process. Normal system
operation
Technical Product Specification
Chassis
ID LED
Status
LED
Solid
Green
Off
Comment
Indicates BMC Linux has booted and manageability
functionality is up and running. Fault/Status LEDs operate
as per usual.
8.4 InfiniBand* Link/Activity LED
The server board provides dedicated LEDs for InfiniBand* Link/Activity. They are located on
the baseboard rear, near diagnostic LED set. This set of LEDs works only on the Intel® Server
Board S2600KPF.
The following table maps the system state to the LED state.
Figure 43. InfiniBand* Link LED (K) and InfiniBand* Activity LED (J)
Table 58. InfiniBand* Link/Activity LED
LED Color
Amber (Right)
Green (Left)
LED State
NIC State
Off
No Logical Link
Blinking
Logical Link established
Off
No Physical Link
On
Physical Link established
8.5 POST Code Diagnostic LEDs
Eight amber POST code diagnostic LEDs are located on the back left edge of the server board,
in the rear I/O area near the QSFP+ connector.
During the system boot process, the BIOS executes a number of platform configuration
processes, each of which is assigned a specific hex POST code number. As each configuration
routine is started, the BIOS displays the given POST code to the POST code diagnostic LEDs
on the back edge of the server board. To assist in troubleshooting a system hang during the
POST process, you can use the Diagnostic LEDs to identify the last POST process executed.
For a complete description of how these LEDs are read and a list of all supported POST codes,
refer to appendix.
94
Revision 1.34
Technical Product Specification
Intel® Light-Guided Diagnostics
Figure 44. Rear Panel Diagnostic LEDs
Revision 1.34
95
Platform Management
9
Technical Product Specification
Platform Management
Platform management is supported by several hardware and software components integrated
on the server board that work together to support the following:

Control system functions – power system, ACPI, system reset control, system
initialization, front panel interface, system event log

Monitor various board and system sensors, regulate platform thermals and
performance in order to maintain (when possible) server functionality in the event of
component failure and/or environmentally stressed conditions

Monitor and report system health

Provide an interface for Server Management Software applications
This chapter provides a high level overview of the platform management features and
functionality implemented on the server board.
The Intel® Server System BMC Firmware External Product Specification (EPS) and the Intel®
Server System BIOS External Product Specification (EPS) for Intel® Server products based on
the Intel® Xeon® processor E5-2600 v3/v4 product family should be referenced for more indepth and design level platform management information.
9.1
Management Feature Set Overview
The following sections outline features that the integrated BMC firmware can support. Support
and utilization for some features is dependent on the server platform in which the server
board is integrated and any additional system level components and options that may be
installed.
9.1.1
96
IPMI 2.0 Features Overview

Baseboard management controller (BMC)

IPMI Watchdog timer

Messaging support, including command bridging and user/session support

Chassis device functionality, including power/reset control and BIOS boot flags
support

Event receiver device: The BMC receives and processes events from other platform
subsystems

Field Replaceable Unit (FRU) inventory device functionality: The BMC supports access
to system FRU devices using IPMI FRU commands

System Event Log (SEL) device functionality: The BMC supports and provides access to
a SEL including SEL Severity Tracking and the Extended SEL

Sensor Data Record (SDR) repository device functionality: The BMC supports storage
and access of system SDRs
Revision 1.34
Technical Product Specification
Platform Management

Sensor device and sensor scanning/monitoring: The BMC provides IPMI management
of sensors. It polls sensors to monitor and report system health

IPMI interfaces
o
Host interfaces include system management software (SMS) with receive
message queue support, and server management mode (SMM)
o
IPMB interface
o
LAN interface that supports the IPMI-over-LAN protocol (RMCP, RMCP+)

Serial-over-LAN (SOL)

ACPI state synchronization: The BMC tracks ACPI state changes that are provided by
the BIOS

BMC self-test: The BMC performs initialization and run-time self-tests and makes
results available to external entities
See also the Intelligent Platform Management Interface Specification Second Generation
v2.0.
9.1.2
Non IPMI Features Overview
The BMC supports the following non-IPMI features.

In-circuit BMC firmware update

Fault resilient booting (FRB): FRB2 is supported by the watchdog timer functionality.

Chassis intrusion detection (dependent on platform support)

Fan speed control with SDR

Fan redundancy monitoring and support

Enhancements to fan speed control

Power supply redundancy monitoring and support

Acoustic management: Support for multiple fan profiles

Signal testing support: The BMC provides test commands for setting and getting
platform signal states

The BMC generates diagnostic beep codes for fault conditions

System GUID storage and retrieval

Front panel management: The BMC controls the system status LED and chassis ID LED.
It supports secure lockout of certain front panel functionality and monitors button
presses. The chassis ID LED is turned on using a front panel button or a command.

Power state retention

Power fault analysis

Intel® Light-Guided Diagnostics

Power unit management: Support for power unit sensor. The BMC handles powergood dropout conditions.
Revision 1.34
97
Platform Management

DIMM temperature monitoring: New sensors and improved acoustic management
using closed-loop fan control algorithm taking into account DIMM temperature
readings.

Address Resolution Protocol (ARP): The BMC sends and responds to ARPs (supported
on embedded NICs).

Dynamic Host Configuration Protocol (DHCP): The BMC performs DHCP (supported on
embedded NICs).

Platform environment control interface (PECI) thermal management support

E-mail alerting

Support for embedded web server UI in Basic Manageability feature set.

Enhancements to embedded web server
o
Human-readable SEL
o
Additional system configurability
o
Additional system monitoring capability
o
Enhanced on-line help

Integrated KVM.

Enhancements to KVM redirection
o
Support for higher resolution

Integrated Remote Media Redirection

Lightweight Directory Access Protocol (LDAP) support

Intel® Intelligent Power Node Manager support

Embedded platform debug feature which allows capture of detailed data for later
analysis.

Provisioning and inventory enhancements:
o
98
Technical Product Specification
Inventory data/system information export (partial SMBIOS table)

DCMI 1.5 compliance (product-specific).

Management support for PMBus* rev1.2 compliant power supplies

BMC Data Repository (Managed Data Region Feature)

Support for an Intel® Local Control Display Panel

System Airflow Monitoring

Exit Air Temperature Monitoring

Ethernet Controller Thermal Monitoring

Global Aggregate Temperature Margin Sensor

Memory Thermal Management

Power Supply Fan Sensors

Energy Star Server Support

Smart Ride Through (SmaRT)/ Closed Loop System Throttling (CLST)
Revision 1.34
Technical Product Specification
Platform Management

Power Supply Cold Redundancy

Power Supply Firmware Update

Power Supply Compatibility Check

BMC firmware reliability enhancements:
9.2
o
Redundant BMC boot blocks to avoid possibility of a corrupted boot block resulting
in a scenario that prevents a user from updating the BMC.
o
BMC System Management Health Monitoring.
Platform Management Features and Functions
9.2.1
Power Subsystem
The server board supports several power control sources which can initiate power-up or
power-down activity.
Power button
External Signal Name or
Internal Subsystem
Front panel power button
Turns power on or off
BMC watchdog timer
Internal BMC timer
Turns power off, or power cycle
BMC chassis control
Commands
Routed through command processor
Turns power on or off, or power cycle
Power state retention
Implemented by means of BMC
internal logic
Turns power on when AC power returns
Chipset
Sleep S4/S5 signal (same as
POWER_ON)
Turns power on or off
CPU Thermal
Processor Thermtrip
Turns power off
PCH Thermal
PCH Thermtrip
Turns power off
Source
9.2.2
Capabilities
Advanced Configuration and Power Interface (ACPI)
The server board has support for the following ACPI states.
Table 59. ACPI Power States
State
S0
Supported
Yes
Description
Working.
 The front panel power LED is on (not controlled by the BMC).
 The fans spin at the normal speed, as determined by sensor inputs.
 Front panel buttons work normally.
S1
No
Not supported.
S2
No
Not supported.
S3
No
Supported only on Workstation platforms. See appropriate Platform Specific Information
for more information.
S4
No
Not supported.
Revision 1.34
99
Platform Management
State
S5
Supported
Yes
Technical Product Specification
Description
Soft off.
 The front panel buttons are not locked.
 The fans are stopped.
 The power-up process goes through the normal boot process.
 The power, reset, and ID buttons are unlocked.
9.2.3
System Initialization
During system initialization, both the BIOS and the BMC initialize the following items.
9.2.3.1
Processor Tcontrol Setting
Processors used with this chipset implement a feature called Tcontrol, which provides a
processor-specific value that can be used to adjust the fan-control behavior to achieve
optimum cooling and acoustics. The BMC reads these from the CPU through PECI Proxy
mechanism provided by Manageability Engine (ME). The BMC uses these values as part of the
fan-speed-control algorithm.
9.2.3.2
Fault Resilient Booting (FRB)
Fault resilient booting (FRB) is a set of BIOS and BMC algorithms and hardware support that
allow a multiprocessor system to boot even if the bootstrap processor (BSP) fails. Only FRB2 is
supported using watchdog timer commands.
FRB2 refers to the FRB algorithm that detects system failures during POST. The BIOS uses the
BMC watchdog timer to back up its operation during POST. The BIOS configures the watchdog
timer to indicate that the BIOS is using the timer for the FRB2 phase of the boot operation.
After the BIOS has identified and saved the BSP information, it sets the FRB2 timer use bit and
loads the watchdog timer with the new timeout interval.
If the watchdog timer expires while the watchdog use bit is set to FRB2, the BMC (if so
configured) logs a watchdog expiration event showing the FRB2 timeout in the event data
bytes. The BMC then hard resets the system, assuming the BIOS-selected reset as the
watchdog timeout action.
The BIOS is responsible for disabling the FRB2 timeout before initiating the option ROM scan
and before displaying a request for a boot password. If the processor fails and causes an FRB2
timeout, the BMC resets the system.
The BIOS gets the watchdog expiration status from the BMC. If the status shows an expired
FRB2 timer, the BIOS enters the failure in the system event log (SEL). In the OEM bytes entry in
the SEL, the last POST code generated during the previous boot attempt is written. FRB2
failure is not reflected in the processor status sensor value.
The FRB2 failure does not affect the front panel LEDs.
100
Revision 1.34
Technical Product Specification
9.2.3.3
Platform Management
Post Code Display
The BMC, upon receiving standby power, initializes internal hardware to monitor port 80h
(POST code) writes. Data written to port 80h is output to the system POST LEDs.
The BMC deactivates POST LEDs after POST had completed.
9.2.4
System Event Log (SEL)
The BMC implements the system event log as specified in the Intelligent Platform
Management Interface Specification, Version 2.0. The SEL is accessible regardless of the
system power state through the BMC's in-band and out-of-band interfaces.
The BMC allocates 95231bytes (approx. 93 KB) of non-volatile storage space to store system
events. The SEL timestamps may not be in order. Up to 3,639 SEL records can be stored at a
time. Because the SEL is circular, any command that results in an overflow of the SEL beyond
the allocated space will overwrite the oldest entries in the SEL, while setting the overflow flag.
9.3
Sensor Monitoring
The BMC monitors system hardware and reports system health. The information gathered
from physical sensors is translated into IPMI sensors as part of the “IPMI Sensor Model”. The
BMC also reports various system state changes by maintaining virtual sensors that are not
specifically tied to physical hardware. This section describes general aspects of BMC sensor
management as well as describing how specific sensor types are modeled. Unless otherwise
specified, the term “sensor” refers to the IPMI sensor-model definition of a sensor.
9.3.1
Sensor Scanning
The value of many of the BMC’s sensors is derived by the BMC firmware periodically polling
physical sensors in the system to read temperature, voltages, and so on. Some of these
physical sensors are built-in to the BMC component itself and some are physically separated
from the BMC. Polling of physical sensors for support of IPMI sensor monitoring does not
occur until the BMC’s operational code is running and the IPMI firmware subsystem has
completed initialization. IPMI sensor monitoring is not supported in the BMC boot code.
Additionally, the BMC selectively polls physical sensors based on the current power and reset
state of the system and the availability of the physical sensor when in that state. For example,
non-standby voltages are not monitored when the system is in S4 or S5 power state.
9.3.2
9.3.2.1
Sensor Rearm Behavior
Manual versus Re-arm Sensors
Sensors can be either manual or automatic re-arm. An automatic re-arm sensor will "re-arm"
(clear) the assertion event state for a threshold or offset if that threshold or offset is deasserted after having been asserted. This allows a subsequent assertion of the threshold or an
offset to generate a new event and associated side-effect. An example side-effect would be
boosting fans due to an upper critical threshold crossing of a temperature sensor. The event
state and the input state (value) of the sensor track each other. Most sensors are auto-rearm.
Revision 1.34
101
Platform Management
Technical Product Specification
A manual re-arm sensor does not clear the assertion state even when the threshold or offset
becomes de-asserted. In this case, the event state and the input state (value) of the sensor do
not track each other. The event assertion state is "sticky". The following methods can be used
to re-arm a sensor:

Automatic re-arm – Only applies to sensors that are designated as “auto-rearm”.

IPMI command Re-arm Sensor Event

BMC internal method – The BMC may re-arm certain sensors due to a trigger
condition. For example, some sensors may be re-armed due to a system reset. A BMC
reset will re-arm all sensors.

System reset or DC power cycle will re-arm all system fan sensors.
9.3.2.2
Re-arm and Event Generation
All BMC-owned sensors that show an asserted event status generate a de-assertion SEL event
when the sensor is re-armed, provided that the associated SDR is configured to enable a deassertion event for that condition. This applies regardless of whether the sensor is a
threshold/analog sensor or a discrete sensor.
To manually re-arm the sensors, the sequence is outlined below:
1. A failure condition occurs and the BMC logs an assertion event.
2. If this failure condition disappears, the BMC logs a de-assertion event (if so configured).
3. The sensor is re-armed by one of the methods described in the previous section.
4. The BMC clears the sensor status.
5. The sensor is put into "reading-state-unavailable" state until it is polled again or
otherwise updated.
6. The sensor is updated and the “reading-state-unavailable” state is cleared. A new
assertion event will be logged if the fault state is once again detected.
All auto-rearm sensors that show an asserted event status generate a de-assertion SEL event
at the time the BMC detects that the condition causing the original assertion is no longer
present; and the associated SDR is configured to enable a de-assertion event for that
condition.
9.3.3
BIOS Event-Only Sensors
BIOS-owned discrete sensors are used for event generation only and are not accessible
through IPMI sensor commands like the Get Sensor Reading command. Note that in this case
the sensor owner designated in the SDR is not the BMC.
An example of this usage would be the SELs logged by the BIOS for uncorrectable memory
errors. Such SEL entries would identify a BIOS-owned sensor ID.
102
Revision 1.34
Technical Product Specification
9.3.4
Platform Management
Margin Sensors
There is sometimes a need for an IPMI sensor to report the difference (margin) from a nonzero reference offset. For the purposes of this document, these type sensors are referred to as
margin sensors. For instance, for the case of a temperature margin sensor, if the reference
value is 90 degrees and the actual temperature of the device being monitored is 85 degrees,
the margin value would be -5.
9.3.5
IPMI Watchdog Sensor
The BMC supports a Watchdog Sensor as a means to log SEL events due to expirations of the
IPMI 2.0 compliant Watchdog Timer.
9.3.6
BMC Watchdog Sensor
The BMC supports an IPMI sensor to report that a BMC reset has occurred due to action taken
by the BMC Watchdog feature. A SEL event will be logged whenever either the BMC firmware
stack is reset or the BMC CPU itself is reset.
9.3.7
BMC System Management Health Monitoring
The BMC tracks the health of each of its IPMI sensors and reports failures by providing a “BMC
FW Health” sensor of the IPMI 2.0 sensor type Management Subsystem Health with support
for the Sensor Failure offset. Only assertions should be logged into the SEL for the Sensor
Failure offset. The BMC Firmware Health sensor asserts for any sensor when 10 consecutive
sensor errors are read. These are not standard sensor events (that is, threshold crossings or
discrete assertions). These are BMC Hardware Access Layer (HAL) errors. If a successful sensor
read is completed, the counter resets to zero.
9.3.8
VR Watchdog Timer
The BMC firmware monitors that the power sequence for the board VR controllers is
completed when a DC power-on is initiated. Incompletion of the sequence indicates a board
problem, in which case the firmware powers down the system.
The BMC firmware supports a discrete IPMI sensor for reporting and logging this fault
condition.
9.3.9
System Airflow Monitoring
This sensor is only valid in Intel chassis. The BMC provides an IPMI sensor to report the
volumetric system airflow in CFM (cubic feet per minute). The air flow in CFM is calculated
based on the system fan PWM values. The specific Pulse Width Modulation (PWM or PWMs)
used to determine the CFM is SDR configurable. The relationship between PWM and CFM is
based on a lookup table in an OEM SDR.
The airflow data is used in the calculation for exit air temperature monitoring. It is exposed as
an IPMI sensor to allow a datacenter management application to access this data for use in
rack-level thermal management.
Revision 1.34
103
Platform Management
9.3.10
Technical Product Specification
Thermal Monitoring
The BMC provides monitoring of component and board temperature sensing devices. This
monitoring capability is instantiated in the form of IPMI analog/threshold or discrete sensors,
depending on the nature of the measurement.
For analog/threshold sensors, with the exception of Processor Temperature sensors, critical
and non-critical thresholds (upper and lower) are set through SDRs and event generation
enabled for both assertion and de-assertion events.
For discrete sensors, both assertion and de-assertion event generation are enabled.
Mandatory monitoring of platform thermal sensors includes:

Inlet temperature (physical sensor is typically on system front panel or HDD
backplane)

Board ambient thermal sensors

Processor temperature

Memory (DIMM) temperature

CPU VRD Hot monitoring

Power supply inlet temperature (only supported for PMBus*-compliant PSUs)
Additionally, the BMC firmware may create “virtual” sensors that are based on a combination
of aggregation of multiple physical thermal sensors and application of a mathematical formula
to thermal or power sensor readings.
9.3.10.1 Absolute Value versus Margin Sensors
Thermal monitoring sensors fall into three basic categories:

Absolute temperature sensors – These are analog/threshold sensors that provide a
value that corresponds to an absolute temperature value.

Thermal margin sensors – These are analog/threshold sensors that provide a value
that is relative to some reference value.

Thermal fault indication sensors – These are discrete sensors that indicate a specific
thermal fault condition.
9.3.10.2 Processor DTS-Spec Margin Sensor(s)
Intel® Server Systems supporting the Intel® Xeon® processor E5-2600 v3/v4 product family
incorporate a DTS based thermal spec. This allows a much more accurate control of the
thermal solution and will enable lower fan speeds and lower fan power consumption. The
main usage of this sensor is as an input to the BMC’s fan control algorithms. The BMC
implements this as a threshold sensor. There is one DTS sensor for each installed physical
processor package. Thresholds are not set and alert generation is not enabled for these
sensors.
104
Revision 1.34
Technical Product Specification
Platform Management
9.3.10.3 Processor Thermal Margin Sensor(s)
Each processor supports a physical thermal margin sensor per core that is readable through
the PECI interface. This provides a relative value representing a thermal margin from the
core’s throttling thermal trip point. Assuming that temp controlled throttling is enabled; the
physical core temp sensor reads ‘0’, which indicates the processor core is being throttled.
The BMC supports one IPMI processor (margin) temperature sensor per physical processor
package. This sensor aggregates the readings of the individual core temperatures in a package
to provide the hottest core temperature reading. When the sensor reads ‘0’, it indicates that
the hottest processor core is throttling.
Due to the fact that the readings are capped at the core’s thermal throttling trip point (reading
= 0), thresholds are not set and alert generation is not enabled for these sensors.
9.3.10.4 Processor Thermal Control Monitoring (Prochot)
The BMC firmware monitors the percentage of time that a processor has been operationally
constrained over a given time window (nominally six seconds) due to internal thermal
management algorithms engaging to reduce the temperature of the device. When any
processor core temperature reaches its maximum operating temperature, the processor
package PROCHOT# (processor hot) signal is asserted and these management algorithms,
known as the Thermal Control Circuit (TCC), engage to reduce the temperature, provided TCC
is enabled. TCC is enabled by BIOS during system boot. This monitoring is instantiated as one
IPMI analog/threshold sensor per processor package. The BMC implements this as a threshold
sensor on a per-processor basis.
Under normal operation, this sensor is expected to read ‘0’ indicating that no processor
throttling has occurred.
The processor provides PECI-accessible counters, one for the total processor time elapsed
and one for the total thermally constrained time, which are used to calculate the percentage
assertion over the given time window.
9.3.10.5 Processor Voltage Regulator (VRD) Over-Temperature Sensor
The BMC monitors processor VRD_HOT# signals. The processor VRD_HOT# signals are routed
to the respective processor PROCHOT# input in order to initiate throttling to reduce processor
power draw, therefore indirectly lowering the VRD temperature.
There is one processor VRD_HOT# signal per CPU slot. The BMC instantiates one discrete IPMI
sensor for each VRD_HOT# signal. This sensor monitors a digital signal that indicates whether
a processor VRD is running in an over-temperature condition. When the BMC detects that this
signal is asserted it will cause a sensor assertion which will result in an event being written into
the sensor event log (SEL).
Revision 1.34
105
Platform Management
Technical Product Specification
9.3.10.6 Inlet Temperature Sensor
Each platform supports a thermal sensor for monitoring the inlet temperature. The inlet
temperature sensor is on the backplane of Intel® Server Chassis with address 21h. For
third-party chassis, sensor 20h which is on the front edge of the baseboard can be used as
inlet temperature sensor with several degrees of preheat from front end.
9.3.10.7 Baseboard Ambient Temperature Sensor(s)
The server baseboard provides one or more physical thermal sensors for monitoring the
ambient temperature of a board location. This is typically to provide rudimentary thermal
monitoring of components that lack internal thermal sensors.
9.3.10.8 Chpiset Thermal Monitoring
The BMC monitors the chipset temperature. This is instantiated as an analog (threshold) IPMI
thermal sensor.
9.3.10.9 Exit Air Temperature Monitoring
This sensor is only available in Intel® Server Chassis. The BMC synthesizes a virtual sensor to
approximate system exit air temperature for use in fan control. This is calculated based on the
total power being consumed by the system and the total volumetric air flow provided by the
system fans. Each system shall be characterized in tabular format to understand total
volumetric flow versus fan speed. The BMC calculates an average exit air temperature based
on the total system power, front panel temperature, the volumetric system air flow (cubic feet
per meter or CFM), and altitude range.
The Exit Air temp sensor is only available when PMBus* power supplies are installed.
9.3.10.10 Ethernet Controller Thermal Monitoring
The Intel® Ethernet Controller I350 supports an on-die thermal sensor. For baseboard
Ethernet controllers that use these devices, the BMC will monitor the sensors and use this
data as an input to the fan speed control. The BMC will instantiate an IPMI temperature sensor
for each device on the baseboard.
9.3.10.11 Memory VRD-Hot Sensor(s)
The BMC monitors memory VRD_HOT# signals. The memory VRD_HOT# signals are routed to
the respective processor MEMHOT# inputs in order to throttle the associated memory to
effectively lower the temperature of the VRD feeding that memory.
For Intel® Server Systems supporting the Intel® Xeon® processor E5-2600 v3/v4 product family
there are 2 memory VRD_HOT# signals per CPU slot. The BMC instantiates one discrete IPMI
sensor for each memory VRD_HOT# signal.
9.3.10.12 Add-in Module Thermal Monitoring
Some boards have dedicated slots for an IO module and/or a SAS module. For boards that
support these slots, the BMC will instantiate an IPMI temperature sensor for each slot. The
106
Revision 1.34
Technical Product Specification
Platform Management
modules themselves may or may not provide a physical thermal sensor (a TMP75 device). If
the BMC detects that a module is installed, it will attempt to access the physical thermal
sensor and, if found, enable the associated IPMI temperature sensor.
9.3.10.13 Processor ThermTrip
When a Processor ThermTrip occurs, the system hardware will automatically power down the
server. If the BMC detects that a ThermTrip occurred, then it will set the ThermTrip offset for
the applicable processor status sensor.
9.3.10.14 Server South Bridge (SSB) ThermTrip Monitoring
The BMC supports SSB ThermTrip monitoring that is instantiated as an IPMI discrete sensor.
When an SSB ThermTrip occurs, the system hardware will automatically power down the
server and the BMC will assert the sensor offset and log an event.
9.3.10.15 DIMM ThermTrip Monitoring
The BMC supports DIMM ThermTrip monitoring that is instantiated as one aggregate IPMI
discrete sensor per CPU. When a DIMM ThermTrip occurs, the system hardware will
automatically power down the server and the BMC will assert the sensor offset and log an
event.
This is a manual re-arm sensor that is rearmed on system resets and power-on (AC or DC
power on transitions).
9.3.11
Processor Sensors
The BMC provides IPMI sensors for processors and associated components, such as voltage
regulators and fans. The sensors are implemented on a per-processor basis.
Table 60. Processor Sensors
Sensor Name
Processor Status
Per-Processor
Socket
Yes
Description
Processor presence and fault state
Digital Thermal Sensor
Yes
Relative temperature reading by means of PECI
Processor VRD Over-Temperature
Indication
Yes
Discrete sensor that indicates a processor VRD has
crossed an upper operating temperature threshold
Processor Voltage
Yes
Threshold sensor that indicates a processor powergood state
Processor Thermal Control (Prochot)
Yes
Percentage of time a processor is throttling due to
thermal conditions
9.3.11.1 Processor Status Sensors
The BMC provides an IPMI sensor of type processor for monitoring status information for each
processor slot. If an event state (sensor offset) has been asserted, it remains asserted until one
of the following happens:
Revision 1.34
107
Platform Management
Technical Product Specification
1. A Rearm Sensor Events command is executed for the processor status sensor.
2. An AC or DC power cycle, system reset, or system boot occurs.
The BMC provides system status indication to the front panel LEDs for processor fault
conditions shown in Table 60.
CPU Presence status is not saved across AC power cycles and therefore will not generate a deassertion after cycling AC power.
Table 61. Processor Status Sensor Implementation
Offset
0
Internal error (IERR)
Detected By
Not Supported
1
Thermal trip
BMC
2
FRB1/BIST failure
Not Supported
3
FRB2/Hang in POST failure
BIOS1
4
FRB3/Processor startup/initialization failure (CPU fails to start)
Not Supported
5
Configuration error (for DMI)
BIOS1
6
SM BIOS uncorrectable CPU-complex error
Not Supported
7
Processor presence detected
BMC
8
Processor disabled
Not Supported
9
Terminator presence detected
Not Supported
Note:
1.
Processor Status
Fault is not reflected in the processor status sensor.
9.3.11.2 Processor Population Fault (CPU Missing) Sensor
The BMC supports a Processor Population Fault sensor. This is used to monitor for the
condition in which processor slots are not populated as required by the platform hardware to
allow power-on of the system.
At BMC startup, the BMC will check for the fault condition and set the sensor state accordingly.
The BMC also checks for this fault condition at each attempt to DC power-on the system. At
each DC power-on attempt, a beep code is generated if this fault is detected.
The following steps are used to correct the fault condition and clear the sensor state:
1. AC power down the server.
2. Install the missing processor into the correct slot.
3. AC power on the server.
9.3.11.3 ERR2 Timeout Monitoring
The BMC supports an ERR2 Timeout Sensor (1 per CPU) that asserts if a CPU’s ERR2 signal has
been asserted for longer than a fixed time period (> 90 seconds). ERR2 is a processor signal
that indicates when the IIO (Integrated IO module in the processor) has a fatal error which
could not be communicated to the core to trigger SMI. ERR2 events are fatal error conditions,
108
Revision 1.34
Technical Product Specification
Platform Management
where the BIOS and OS will attempt to gracefully handle error, but may not be always do so
reliably. A continuously asserted ERR2 signal is an indication that the BIOS cannot service the
condition that caused the error. This is usually because that condition prevents the BIOS from
running.
When an ERR2 timeout occurs, the BMC asserts/de-asserts the ERR2 Timeout Sensor, and logs
a SEL event for that sensor. The default behavior for BMC core firmware is to initiate a system
reset upon detection of an ERR2 timeout. The BIOS setup utility provides an option to disable
or enable system reset by the BMC for detection of this condition.
9.3.11.4 CATERR Sensor
The BMC supports a CATERR sensor for monitoring the system CATERR signal.
The CATERR signal is defined as having 3 states:

high (no event)

pulsed low (possibly fatal may be able to recover)

low (fatal)
All processors in a system have their CATERR pins tied together. The pin is used as a
communication path to signal a catastrophic system event to all CPUs. The BMC has direct
access to this aggregate CATERR signal.
The BMC only monitors for the “CATERR held low” condition. A pulsed low condition is
ignored by the BMC. If a CATERR-low condition is detected, the BMC logs an error message to
the SEL against the CATERR sensor and the default action after logging the SEL entry is to
reset the system. The BIOS setup utility provides an option to disable or enable system reset
by the BMC for detection of this condition.
The sensor is rearmed on power-on (AC or DC power on transitions). It is not rearmed on
system resets in order to avoid multiple SEL events that could occur due to a potential reset
loop if the CATERR keeps recurring, which would be the case if the CATERR was due to an
MSID mismatch condition.
When the BMC detects that this aggregate CATERR signal has asserted, it can then go through
PECI to query each CPU to determine which one was the source of the error and write an OEM
code identifying the CPU slot into an event data byte in the SEL entry. If PECI is non-functional
(it isn’t guaranteed in this situation), then the OEM code should indicate that the source is
unknown.
Event data byte 2 and byte 3 for CATERR sensor SEL events
ED1 – 0xA1
ED2 - CATERR type.
0: Unknown
1: CATERR
Revision 1.34
109
Platform Management
Technical Product Specification
2: CPU Core Error (not supported on Intel® Server Systems supporting the Intel® Xeon®
processor E5-2600 v3/v4 product family)
3: MSID Mismatch
4: CATERR due to CPU 3-strike timeout
ED3 - CPU bitmap that causes the system CATERR.
[0]: CPU1
[1]: CPU2
[2]: CPU3
[3]: CPU4
When a CATERR Timeout event is determined to be a CPU 3-strike timeout, the BMC shall log
the logical FRU information (e.g. bus/dev/func for a PCIe device, CPU, or DIMM) that identifies
the FRU that caused the error in the extended SEL data bytes. In this case, Ext-ED0 will be set
to 0x70 and the remaining ED1-ED7 will be set according to the device type and info available.
9.3.11.5 MSID Mismatch Sensor
The BMC supports an MSID Mismatch sensor for monitoring for the fault condition that will
occur if there is a power rating incompatibility between a baseboard and a processor.
The sensor is rearmed on power-on (AC or DC power on transitions).
9.3.12
Voltage Monitoring
The BMC provides voltage monitoring capability for voltage sources on the main board and
processors such that all major areas of the system are covered. This monitoring capability is
instantiated in the form of IPMI analog/threshold sensors.
9.3.12.1 DIMM Voltage Sensors
Some systems support either LVDDR (Low Voltage DDR) memory or regular (non-LVDDR)
memory. During POST, the system BIOS detects which type of memory is installed and
configures the hardware to deliver the correct voltage.
Since the nominal voltage range is different, this necessitates the ability to set different
thresholds for any associated IPMI voltage sensors. The BMC firmware supports this by
implementing separate sensors (that is, separate IPMI sensor numbers) for each nominal
voltage range supported for a single physical sensor and it enables/disables the correct IPMI
sensor based on which type memory is installed. The sensor data records for both these DIMM
voltage sensor types have scanning disabled by default. Once the BIOS has completed its
POST routine, it is responsible for communicating the DIMM voltage type to the BMC which
will then enable sensor scanning of the correct DIMM voltage sensor.
9.3.13
Fan Monitoring
BMC fan monitoring support includes monitoring of fan speed (RPM) and fan presence.
110
Revision 1.34
Technical Product Specification
Platform Management
9.3.13.1 Fan Tach Sensors
Fan Tach sensors are used for fan failure detection. The reported sensor reading is
proportional to the fan’s RPM. This monitoring capability is instantiated in the form of IPMI
analog/threshold sensors.
Most fan implementations provide for a variable speed fan, so the variations in fan speed can
be large. Therefore the threshold values must be set sufficiently low as not to result in
inappropriate threshold crossings.
Fan tach sensors are implemented as manual re-arm sensors because a lower-critical
threshold crossing can result in full boosting of the fans. This in turn may cause a failing fan’s
speed to rise above the threshold and can result in fan oscillations.
As a result, fan tach sensors do not auto-rearm when the fault condition goes away but rather
are rearmed for either of the following occurrences:
1. The system is reset or power-cycled.
2. The fan is removed and either replaced with another fan or re-inserted. This applies to
hot-swappable fans only. This re-arm is triggered by change in the state of the
associated fan presence sensor.
After the sensor is rearmed, if the fan speed is detected to be in a normal range, the failure
conditions shall be cleared and a de-assertion event shall be logged.
9.3.13.2 Fan Presence Sensors
Some chassis and server boards provide support for hot-swap fans. These fans can be
removed and replaced while the system is powered on and operating normally. The BMC
implements fan presence sensors for each hot swappable fan. These are instantiated as IPMI
discrete sensors.
Events are only logged for fan presence upon changes in the presence state after AC power is
applied (no events logged for initial state).
9.3.13.3 Fan Redundancy Sensor
The BMC supports redundant fan monitoring and implements fan redundancy sensors for
products that have redundant fans. Support for redundant fans is chassis-specific.
A fan redundancy sensor generates events when its associated set of fans transits between
redundant and non-redundant states, as determined by the number and health of the
component fans. The definition of fan redundancy is configuration dependent. The BMC
allows redundancy to be configured on a per fan-redundancy sensor basis through OEM SDR
records.
There is a fan redundancy sensor implemented for each redundant group of fans in the
system.
Revision 1.34
111
Platform Management
Technical Product Specification
Assertion and de-assertion event generation is enabled for each redundancy state.
9.3.13.4 Power Supply Fan Sensors
Monitoring is implemented through IPMI discrete sensors, one for each power supply fan. The
BMC polls each installed power supply using the PMBus* fan status commands to check for
failure conditions for the power supply fans. The BMC asserts the “performance lags” offset of
the IPMI sensor if a fan failure is detected.
Power supply fan sensors are implemented as manual re-arm sensors because a failure
condition can result in boosting of the fans. This in turn may cause a failing fan’s speed to rise
above the “fault” threshold and can result in fan oscillations. As a result, these sensors do not
auto-rearm when the fault condition goes away but rather are rearmed only when the system
is reset or power-cycled, or the PSU is removed and replaced with the same or another PSU.
After the sensor is rearmed, if the fan is no longer showing a failed state, the failure condition
in the IPMI sensor shall be cleared and a de-assertion event shall be logged.
9.3.13.5 Monitoring for “Fans Off” Scenario
On Intel® Server Systems supporting the Intel® Xeon® processor E5-2600 v3/v4 product family,
it is likely that there will be situations where specific fans are turned off based on current
system conditions. BMC Fan monitoring will comprehend this scenario and not log false failure
events. The recommended method is for the BMC firmware to halt updates to the value of the
associated fan tach sensor and set that sensor’s IPMI sensor state to “reading-stateunavailable” when this mode is active. Management software must comprehend this state for
fan tach sensors and not report these as failure conditions.
The scenario for which this occurs is that the BMC Fan Speed Control (FSC) code turns off the
fans by setting the PWM for the domain to 0. This is done when based on one or more global
aggregate thermal margin sensor readings dropping below a specified threshold.
By default the fans-off feature will be disabled. There is a BMC command and BIOS setup
option to enable/disable this feature.
The SmaRT/CLST system feature will also momentarily gate power to all the system fans to
reduce overall system power consumption in response to a power supply event (for example,
to ride out an AC power glitch). However, for this scenario, the fan power is gated by hardware
for only 100ms, which should not be long enough to result in triggering a fan fault SEL event.
9.3.14
Standard Fan Management
The BMC controls and monitors the system fans. Each fan is associated with a fan speed
sensor that detects fan failure and may also be associated with a fan presence sensor for hotswap support. For redundant fan configurations, the fan failure and presence status
determines the fan redundancy sensor state.
112
Revision 1.34
Technical Product Specification
Platform Management
The system fans are divided into fan domains, each of which has a separate fan speed control
signal and a separate configurable fan control policy. A fan domain can have a set of
temperature and fan sensors associated with it. These are used to determine the current fan
domain state.
A fan domain has three states:

The sleep and boost states have fixed (but configurable through OEM SDRs) fan
speeds associated with them.

The nominal state has a variable speed determined by the fan domain policy. An OEM
SDR record is used to configure the fan domain policy.
The fan domain state is controlled by several factors. They are listed below in order of
precedence, high to low:


Boost
o
Associated fan is in a critical state or missing. The SDR describes which fan domains
are boosted in response to a fan failure or removal in each domain. If a fan is
removed when the system is in ‘Fans-off’ mode it will not be detected and there
will not be any fan boost till system comes out of ‘Fans-off’ mode.
o
Any associated temperature sensor is in a critical state. The SDR describes which
temperature-threshold violations cause fan boost for each fan domain.
o
The BMC is in firmware update mode, or the operational firmware is corrupted.
o
If any of the above conditions apply, the fans are set to a fixed boost state speed.
Nominal
o
A fan domain’s nominal fan speed can be configured as static (fixed value) or
controlled by the state of one or more associated temperature sensors.
o
See section 9.3.14.3 for more details.
9.3.14.1 Fan Redundancy Detection
The BMC supports redundant fan monitoring and implements a fan redundancy sensor. A fan
redundancy sensor generates events when its associated set of fans transits between
redundant and non-redundant states, as determined by the number and health of the fans.
The definition of fan redundancy is configuration dependent. The BMC allows redundancy to
be configured on a per fan redundancy sensor basis through OEM SDR records.
A fan failure or removal of hot-swap fans up to the number of redundant fans specified in the
SDR in a fan configuration is a non-critical failure and is reflected in the front panel status. A
fan failure or removal that exceeds the number of redundant fans is a non-fatal, insufficientresources condition and is reflected in the front panel status as a non-fatal error.
Redundancy is checked only when the system is in the DC-on state. Fan redundancy changes
that occur when the system is DC-off or when AC is removed will not be logged until the
system is turned on.
Revision 1.34
113
Platform Management
Technical Product Specification
9.3.14.2 Fan Domains
System fan speeds are controlled through pulse width modulation (PWM) signals, which are
driven separately for each domain by integrated PWM hardware. Fan speed is changed by
adjusting the duty cycle, which is the percentage of time the signal is driven high in each pulse.
The BMC controls the average duty cycle of each PWM signal through direct manipulation of
the integrated PWM control registers.
The same device may drive multiple PWM signals.
9.3.14.3 Nominal Fan Speed
A fan domain’s nominal fan speed can be configured as static (fixed value) or controlled by the
state of one or more associated temperature sensors.
OEM SDR records are used to configure which temperature sensors are associated with which
fan control domains and the algorithmic relationship between the temperature and fan speed.
Multiple OEM SDRs can reference or control the same fan control domain; and multiple OEM
SDRs can reference the same temperature sensors.
The PWM duty-cycle value for a domain is computed as a percentage using one or more
instances of a stepwise linear algorithm and a clamp algorithm. The transition from one
computed nominal fan speed (PWM value) to another is ramped over time to minimize audible
transitions. The ramp rate is configurable by means of the OEM SDR.
Multiple stepwise linear and clamp controls can be defined for each fan domain and used
simultaneously. For each domain, the BMC uses the maximum of the domain’s stepwise linear
control contributions and the sum of the domain’s clamp control contributions to compute
the domain’s PWM value, except that a stepwise linear instance can be configured to provide
the domain maximum.
Hysteresis can be specified to minimize fan speed oscillation and to smooth fan speed
transitions. If a Tcontrol SDR record does not contain a hysteresis definition, for example, an
SDR adhering to a legacy format, the BMC assumes a hysteresis value of zero.
9.3.14.4 Thermal and Acoustic Management
This feature refers to enhanced fan management to keep the system optimally cooled while
reducing the amount of noise generated by the system fans. Aggressive acoustics standards
might require a trade-off between fan speed and system performance parameters that
contribute to the cooling requirements, primarily memory bandwidth. The BIOS, BMC, and
SDRs work together to provide control over how this trade-off is determined.
This capability requires the BMC to access temperature sensors. Additionally, closed-loop
thermal throttling is only supported with DIMMs with temperature sensors.
114
Revision 1.34
Technical Product Specification
Platform Management
9.3.14.5 Thermal Sensor Input to Fan Speed Control
The BMC uses various IPMI sensors as input to the fan speed control. Some of the sensors are
IPMI models of actual physical sensors whereas some are “virtual” sensors whose values are
derived from physical sensors using calculations and/or tabular information.
The following IPMI thermal sensors are used as input to the fan speed control:

Front panel temperature sensor

Baseboard temperature sensors

CPU DTS-Spec margin sensors

DIMM thermal margin sensors

Exit air temperature sensor

Global aggregate thermal margin sensors

SSB (Intel® C610 Series Chipset) temperature sensor

On-board Ethernet controller temperature sensors (support for this is specific to the
Ethernet controller being used)

Add-in Intel® SAS/IO module temperature sensor(s) (if present)

Power supply thermal sensors (only available on PMBus*-compliant power supplies)
A simple model is shown in the following figure which gives a high level graphic of the fan
speed control structure creates the resulting fan speeds.
Memory
Throttle
Settings
Policy: CLTT,
Acoustic/Performance,
Auto-Profile
configuration
Front Panel
Policy
Events
Sensor
Intrusion
System Behavior
Resulting Fan
Speed
Processor
Margin
Fan Failure
Power Supply
Failure
Other Sensors
(Chipset, Temp,
etc..)
Figure 45. High-level Fan Speed Control Process
Revision 1.34
115
Platform Management
Technical Product Specification
9.3.14.5.1 Processor Thermal Management
Processor thermal management utilizes clamp algorithms for which the Processor DTS-Spec
margin sensor is a controlling input. This replaces the use of the (legacy) raw DTS sensor
reading that was utilized on previous generation platforms. The legacy DTS sensor is retained
only for monitoring purposes and is not used as an input to the fan speed control.
9.3.14.5.2 Memory Thermal Management
The system memory is the most complex subsystem to thermally manage as it requires
substantial interactions between the BMC, BIOS, and the embedded memory controller. This
section provides an overview of this management capability from a BMC perspective.
9.3.14.5.2.1
Memory Thermal Throttling
The system supports thermal management through closed loop throttling (CLTT) with
memory with temperature sensors. Throttling levels are changed dynamically to cap throttling
based on memory and system thermal conditions as determined by the system and DIMM
power and thermal parameters. The BMC fan speed control functionality is related to the
memory throttling mechanism used.
The following terminology is used for the various memory throttling options:

Static Closed Loop Thermal Throttling (Static-CLTT): CLTT control registers are
configured by BIOS MRC during POST. The memory throttling is run as a closed-loop
system with the DIMM temperature sensors as the control input. Otherwise, the
system does not change any of the throttling control registers in the embedded
memory controller during runtime.

Dynamic Closed Loop Thermal Throttling (Dynamic-CLTT): CLTT control registers are
configured by BIOS MRC during POST. The memory throttling is run as a closed-loop
system with the DIMM temperature sensors as the control input. Adjustments are
made to the throttling during runtime based on changes in system cooling (fan speed).
9.3.14.5.3DIMM Temperature Sensor Input to Fan Speed Control
A clamp algorithm is used for controlling fan speed based on DIMM temperatures. Aggregate
DIMM temperature margin sensors are used as the control input to the algorithm.
9.3.14.5.4Dynamic (Hybrid) CLTT
The system will support dynamic (memory) CLTT for which the BMC firmware dynamically
modifies thermal offset registers in the IMC during runtime based on changes in system
cooling (fan speed). For static CLTT, a fixed offset value is applied to the TSOD reading to get
the die temperature; however this does not provide as accurate results as when the offset
takes into account the current airflow over the DIMM, as is done with dynamic CLTT.
In order to support this feature, the BMC firmware will derive the air velocity for each fan
domain based on the PWM value being driven for the domain. Since this relationship is
dependent on the chassis configuration, a method must be used which supports this
116
Revision 1.34
Technical Product Specification
Platform Management
dependency (for example, through OEM SDR) that establishes a lookup table providing this
relationship.
BIOS will have an embedded lookup table that provides thermal offset values for each DIMM
type, altitude setting, and air velocity range (3 ranges of air velocity are supported). During
system boot BIOS will provide 3 offset values (corresponding to the 3 air velocity ranges) to
the BMC for each enabled DIMM. Using this data the BMC firmware constructs a table that
maps the offset value corresponding to a given air velocity range for each DIMM. During
runtime the BMC applies an averaging algorithm to determine the target offset value
corresponding to the current air velocity and then the BMC writes this new offset value into
the IMC thermal offset register for the DIMM.
9.3.14.5.5 Auto-profile
The auto-profile feature is to improve upon previous platform configuration-dependent FSC
and maintain competitive acoustics. This feature is not available for third-party customization.
The BIOS and BMC will handshake to automatically understand configuration details and
automatically select the optimal fan speed control profile in the BMC.
Users will only select a performance or an acoustic profile selection from the BIOS menu for
use with Intel® Server Chassis and the fan speed control will be optimal for the configuration
loaded.
Users can still choose performance or acoustic profile in BIOS setting. Default is acoustic.
Performance option is recommended if any other high power add-in cards (higher than 75W)
are installed.
9.3.14.5.6ASHRAE Compliance
There is no manual selection of profiles at different altitudes. Altitude impact is covered by
auto-profile.
9.3.14.6 Power Supply Fan Speed Control
This section describes the system level control of the fans internal to the power supply over
the PMBus*. Some, but not all Intel® Server Systems supporting the Intel® Xeon® processor E52600 v3/v4 product family will require that the power supplies be included in the system level
fan speed control. For any system that requires either of these capabilities, the power supply
must be PMBus*-compliant.
9.3.14.6.1System Control of Power Supply Fans
Some products require that the BMC control the speed of the power supply fans, as is done
with normal system (chassis) fans, except that the BMC cannot reduce the power supply fan
any lower than the internal power supply control is driving it. For these products the BMC
firmware must have the ability to control and monitor the power supply fans through PMBus*
commands. The power supply fans are treated as a system fan domain for which fan control
policies are mapped, just as for chassis system fans, with system thermal sensors (rather than
Revision 1.34
117
Platform Management
Technical Product Specification
internal power supply thermal sensors) used as the input to a clamp algorithm for the power
supply fan control. This domain has both piecewise clipping curves and clamped sensors
mapped into the power supply fan domain. All the power supplies can be defined as a single
fan domain.
9.3.14.6.2Use of Power Supply Thermal Sensors as Input to System (Chassis) Fan Control
Some products require that the power supply internal thermal sensors are used as control
inputs to the system (chassis) fans, in the same manner as other system thermal sensors are
used for this purpose. The power supply thermal sensors are included as clamped sensors
into one or more system fan domains, which may include the power supply fan domain.
9.3.14.7 Fan Boosting due to Fan Failures
Intel® Server Systems supporting the Intel® Xeon® processor E5-2600 v3/v4 product family
introduce additional capabilities for handling fan failure or removal as described in this
section.
Each fan failure shall be able to define a unique response from all other fan domains. An OEM
SDR table defines the response of each fan domain based on a failure of any fan, including
both system and power supply fans (for PMBus*-compliant power supplies only). This means
that if a system has six fans, then there will be six different fan fail reactions.
9.3.14.8 Programmable Fan PWM Offset
The system provides a BIOS Setup option to boost the system fan speed by a programmable
positive offset or a “Max” setting. Setting the programmable offset causes the BMC to add the
offset to the fan speeds that it would otherwise be driving the fans to. The Max setting causes
the BMC to replace the domain minimum speed with alternate domain minimums that also are
programmable through SDRs.
This capability is offered to provide system administrators the option to manually configure
fans speeds in instances where the fan speed optimized for a given platform may not be
sufficient when a high end add-in is configured into the system. This enables easier usage of
the fan speed control to support Intel as well as third party chassis and better support of
ambient temperatures higher than 35C.
9.3.15
Power Management Bus (PMBus*)
The Power Management Bus (“PMBus*”) is an open standard protocol that is built upon the
SMBus* 2.0 transport. It defines a means of communicating with power conversion and other
devices using SMBus*-based commands. A system must have PMBus*-compliant power
supplies installed in order for the BMC or ME to monitor them for status and/or power
metering purposes.
For more information on PMBus*, please see the System Management Interface Forum Web
site http://www.powersig.org/.
118
Revision 1.34
Technical Product Specification
9.3.16
Platform Management
Power Supply Dynamic Redundancy Sensor
The BMC supports redundant power subsystems and implements a Power Unit Redundancy
sensor per platform. A Power Unit Redundancy sensor is of sensor type Power Unit (09h) and
reading type Availability Status (0Bh). This sensor generates events when a power subsystem
transitions between redundant and non-redundant states, as determined by the number and
health of the power subsystem’s component power supplies. The BMC implements Dynamic
Power Supply Redundancy status based upon current system load requirements as well as
total Power Supply capacity. This status is independent of the Cold Redundancy status. This
prevents the BMC from reporting Fully Redundant Power supplies when the load required by
the system exceeds half the power capability of all power supplies installed and operational.
Dynamic Redundancy detects this condition and generates the appropriate SEL event to notify
the user of the condition. Power supplies of different power ratings may be swapped in and
out to adjust the power capacity and the BMC will adjust the Redundancy status accordingly.
The definition of redundancy is power subsystem dependent and sometimes even
configuration dependent. See the appropriate Platform Specific Information for power unit
redundancy support.
This sensor is configured as manual-rearm sensor in order to avoid the possibility of
extraneous SEL events that could occur under certain system configuration and workload
conditions. The sensor shall rearm for the following conditions:

PSU hot-add

System reset

AC power cycle

DC power cycle
System AC power is applied but on standby – Power unit redundancy is based on OEM SDR
power unit record and number of PSU present.
System is (DC) powered on - The BMC calculates Dynamic Power Supply Redundancy status
based upon current system load requirements as well as total Power Supply capacity.
The BMC allows redundancy to be configured on a per power-unit-redundancy sensor basis
by means of the OEM SDR records.
9.3.17
Component Fault LED Control
Several sets of component fault LEDs are supported on the server board (see Figure 7). Some
LEDs are owned by the BMC and some by the BIOS.
The BMC owns control of the following FRU/fault LED:

Hard Disk Drive Status LEDs – The HSBP PSoC* owns the hardware control for these
LEDs and detection of the fault/status conditions that the LEDs reflect.
Revision 1.34
119
Platform Management
Technical Product Specification
Table 62. Component Fault LEDs
Component
HDD Fault LED
9.3.18
Owner
HSBP
PSoC*
Color
Amber
Amber
Amber
State
On
Blink
Off
Description
HDD Fault
Predictive failure, rebuild, identify
Ok (no errors)
CMOS Battery Monitoring
The BMC monitors the voltage level from the CMOS battery, which provides battery backup to
the chipset RTC. This is monitored as an auto-rearm threshold sensor.
Unlike monitoring of other voltage sources for which the Emulex* Pilot III component
continuously cycles through each input, the voltage channel used for the battery monitoring
provides a software enable bit to allow the BMC firmware to poll the battery voltage at a
relatively slow rate in order to conserve battery power.
9.4
Intel® Intelligent Power Node Manager (NM)
Power management deals with requirements to manage processor power consumption and
manage power at the platform level to meet critical business needs. Node Manager (NM) is a
platform resident technology that enforces power capping and thermal-triggered power
capping policies for the platform. These policies are applied by exploiting subsystem settings
(such as processor P and T states) that can be used to control power consumption. NM
enables data center power management by exposing an external interface to management
software through which platform policies can be specified. It also implements specific data
center power management usage models such as power limiting, and thermal monitoring.
The NM feature is implemented by a complementary architecture utilizing the ME, BMC, BIOS,
and an ACPI-compliant OS. The ME provides the NM policy engine and power control/limiting
functions (referred to as Node Manager or NM) while the BMC provides the external LAN link
by which external management software can interact with the feature. The BIOS provides
system power information utilized by the NM algorithms and also exports ACPI Source
Language (ASL) code used by OS-Directed Power Management (OSPM) for negotiating
processor P and T state changes for power limiting. PMBus*-compliant power supplies
provide the capability to monitor input power consumption, which is necessary to support NM.
The NM architecture applicable to this generation of servers is defined by the NPTM
Architecture Specification v2.0. NPTM is an evolving technology that is expected to continue to
add new capabilities that will be defined in subsequent versions of the specification. The ME
NM implements the NPTM policy engine and control/monitoring algorithms defined in the
Node Power and Thermal Manager (NPTM) specification.
9.4.1 Hardware Requirements
NM is supported only on platforms that have the NM firmware functionality loaded and
enabled on the Management Engine (ME) in the SSB and that have a BMC present to support
120
Revision 1.34
Technical Product Specification
Platform Management
the external LAN interface to the ME. NM power limiting feature requires a means for the ME to
monitor input power consumption for the platform. This capability is generally provided by
means of PMBus*-compliant power supplies although an alternative model using a simpler
SMBus* power monitoring device is possible (there is potential loss in accuracy and
responsiveness using non-PMBus* devices). The NM SmaRT/CLST feature does specifically
require PMBus*-compliant power supplies as well as additional hardware on the server board.
9.4.2 Features
NM provides feature support for policy management, monitoring and querying, alerts and
notifications, and an external interface protocol. The policy management features implement
specific IT goals that can be specified as policy directives for NM. Monitoring and querying
features enable tracking of power consumption. Alerts and notifications provide the
foundation for automation of power management in the data center management stack. The
external interface specifies the protocols that must be supported in this version of NM.
9.4.3 ME System Management Bus (SMBus*) Interface

The ME uses the SMLink0 on the SSB in multi-master mode as a dedicated bus for
communication with the BMC using the IPMB protocol. The BMC firmware considers
this a secondary IPMB bus and runs at 400 kHz.

The ME uses the SMLink1 on the SSB in multi-master mode bus for communication
with PMBus* devices in the power supplies for support of various NM-related features.
This bus is shared with the BMC, which polls these PMBus* power supplies for sensor
monitoring purposes (for example, power supply status, input power, and so on). This
bus runs at 100 KHz.

The Management Engine has access to the “Host SMBus*”.
9.4.4 PECI 3.0

The BMC owns the PECI bus for all Intel server implementations and acts as a proxy
for the ME when necessary.
9.4.5 NM “Discovery” OEM SDR
An NM “discovery” OEM SDR must be loaded into the BMC’s SDR repository if and only if the
NM feature is supported on that product. This OEM SDR is used by management software to
detect if NM is supported and to understand how to communicate with it.
Since PMBus* compliant power supplies are required in order to support NM, the system
should be probed when the SDRs are loaded into the BMC’s SDR repository in order to
determine whether or not the installed power supplies do in fact support PMBus*. If the
installed power supplies are not PMBus* compliant then the NM “discovery” OEM SDR should
not be loaded.
Please refer to the Intel® Intelligent Power Node Manager 2.0 External Architecture
Specification using IPMI for details of this interface.
Revision 1.34
121
Platform Management
Technical Product Specification
9.4.6 SmaRT/CLST
The power supply optimization provided by SmaRT/CLST relies on a platform hardware
capability as well as ME firmware support. When a PMBus*-compliant power supply detects
insufficient input voltage, an overcurrent condition, or an over-temperature condition, it will
assert the SMBAlert# signal on the power supply SMBus* (such as, the PMBus*). Through the
use of external gates, this results in a momentary assertion of the PROCHOT# and MEMHOT#
signals to the processors, thereby throttling the processors and memory. The ME firmware
also sees the SMBAlert# assertion, queries the power supplies to determine the condition
causing the assertion, and applies an algorithm to either release or prolong the throttling,
based on the situation.
System power control modes include:
1. SmaRT: Low AC input voltage event; results in a one-time momentary throttle for each
event to the maximum throttle state.
2. Electrical Protection CLST: High output energy event; results in a throttling hiccup
mode with fixed maximum throttle time and a fixed throttle release ramp time.
3. Thermal Protection CLST: High power supply thermal event; results in a throttling
hiccup mode with fixed maximum throttle time and a fixed throttle release ramp time.
When the SMBAlert# signal is asserted, the fans will be gated by hardware for a short period
(~100ms) to reduce overall power consumption. It is expected that the interruption to the fans
will be of short enough duration to avoid false lower threshold crossings for the fan tach
sensors; however, this may need to be comprehended by the fan monitoring firmware if it
does have this side-effect.
ME firmware will log an event into the SEL to indicate when the system has been throttled by
the SmaRT/CLST power management feature. This is dependent on ME firmware support for
this sensor. Please refer to the ME firmware EPS for SEL log details.
9.4.6.1.1 Dependencies on PMBus*-compliant Power Supply Support
The SmaRT/CLST system feature depends on functionality present in the ME NM SKU. This
feature requires power supplies that are compliant with the PMBus.
Note: For additional information on Intel® Intelligent Power Node Manager usage and support,
please visit the following Intel Website:
http://www.intel.com/content/www/us/en/data-center/data-center-management/nodemanager-general.html?wapkw=node+manager
9.5 Basic and Advanced Server Management Features
The integrated BMC has support for basic and advanced server management features. Basic
management features are available by default. Advanced management features are enabled
with the addition of an optionally installed Remote Management Module 4 Lite (RMM4 Lite)
key.
122
Revision 1.34
Technical Product Specification
Platform Management
Table 63. Intel® Remote Management Module 4 (RMM4) Options
Intel Product
Code
AXXRMM4LITE
Description
Kit Contents
Intel® Remote Management Module
4 Lite
RMM4 Lite Activation
Key
Benefits
Enables KVM & media
redirection
When the BMC firmware initializes, it attempts to access the Intel® RMM4 lite. If the attempt to
access Intel® RMM4 lite is successful, then the BMC activates the advanced features.
The following table identifies both basic and advanced server management features.
Table 64. Basic and Advanced Server Management Features Overview
Feature
IPMI 2.0 Feature Support
Basic
X
Advanced
X
In-circuit BMC Firmware Update
X
X
FRB 2
X
X
Chassis Intrusion Detection
X
X
Fan Redundancy Monitoring
X
X
Hot-Swap Fan Support
X
X
Acoustic Management
X
X
Diagnostic Beep Code Support
X
X
Power State Retention
X
X
ARP/DHCP Support
X
X
PECI Thermal Management Support
X
X
E-mail Alerting
X
X
Embedded Web Server
X
X
SSH Support
X
X
Integrated KVM
X
Integrated Remote Media Redirection
X
Lightweight Directory Access Protocol (LDAP)
X
X
Intel®
X
X
X
X
Intelligent Power Node Manager Support
SMASH CLP
9.5.1 Dedicated Management Port
The server board includes a dedicated 1GbE RJ45 Management Port. The management port is
active with or without the RMM4 Lite key installed.
9.5.2 Embedded Web Server
BMC Base manageability provides an embedded web server and an OEM-customizable web
GUI which exposes the manageability features of the BMC base feature set. It is supported
over all on-board NICs that have management connectivity to the BMC as well as an optional
Revision 1.34
123
Platform Management
Technical Product Specification
dedicated add-in management NIC. At least two concurrent web sessions from up to two
different users are supported. The embedded web user interface shall support the following
client web browsers:

Microsoft Internet Explorer 9.0*

Microsoft Internet Explorer 10.0*

Mozilla Firefox 24*

Mozilla Firefox 25*
The embedded web user interface supports strong security (authentication, encryption, and
firewall support) since it enables remote server configuration and control. The user interface
presented by the embedded web user interface, shall authenticate the user before allowing a
web session to be initiated. Encryption using 128-bit SSL is supported. User authentication is
based on user id and password.
The GUI presented by the embedded web server authenticates the user before allowing a web
session to be initiated. It presents all functions to all users but grays-out those functions that
the user does not have privilege to execute. For example, if a user does not have privilege to
power control, then the item shall be displayed in grey-out font in that user’s UI display. The
web GUI also provides a launch point for some of the advanced features, such as KVM and
media redirection. These features are grayed out in the GUI unless the system has been
updated to support these advanced features. The embedded web server only displays US
English or Chinese language output.
Additional features supported by the web GUI includes:
124

Presents all the Basic features to the users

Power on/off/reset the server and view current power state

Display BIOS, BMC, ME and SDR version information

Display overall system health.

Configuration of various IPMI over LAN parameters for both IPV4 and IPV6

Configuration of alerting (SNMP and SMTP)

Display system asset information for the product, board, and chassis.

Display of BMC-owned sensors (name, status, current reading, enabled thresholds),
including color-code status of sensors.

Provide ability to filter sensors based on sensor type (Voltage, Temperature, Fan and
Power supply related)

Automatic refresh of sensor data with a configurable refresh rate

On-line help

Display/clear SEL (display is in easily understandable human readable format)

Supports major industry-standard browsers (Microsoft Internet Explorer* and Mozilla
Firefox*)
Revision 1.34
Technical Product Specification
Platform Management

The GUI session automatically times-out after a user-configurable inactivity period. By
default, this inactivity period is 30 minutes.

Embedded Platform Debug feature - Allow the user to initiate a “debug dump” to a file
that can be sent to Intel for debug purposes.

Virtual Front Panel. The Virtual Front Panel provides the same functionality as the
local front panel. The displayed LEDs match the current state of the local panel LEDs.
The displayed buttons (for example, power button) can be used in the same manner as
the local buttons.

Display of ME sensor data. Only sensors that have associated SDRs loaded will be
displayed.

Ability to save the SEL to a file

Ability to force HTTPS connectivity for greater security. This is provided through a
configuration option in the UI.

Display of processor and memory information as is available over IPMI over LAN.

Ability to get and set Node Manager (NM) power policies

Display of power consumed by the server

Ability to view and configure VLAN settings

Warn user the reconfiguration of IP address will cause disconnect.

Capability to block logins for a period of time after several consecutive failed login
attempts. The lock-out period and the number of failed logins that initiates the lockout period are configurable by the user.

Server Power Control - Ability to force into Setup on a reset

System POST results – The web server provides the system’s Power-On Self Test
(POST) sequence for the previous two boot cycles, including timestamps. The
timestamps may be viewed in relative to the start of POST or the previous POST code.

Customizable ports - The web server provides the ability to customize the port
numbers used for SMASH, http, https, KVM, secure KVM, remote media, and secure
remote media.
For additional information, reference the Intel® Remote Management Module 4 and Integrated
BMC Web Console Users Guide.
9.5.3 Advanced Management Feature Support (RMM4 Lite)
The integrated baseboard management controller has support for advanced management
features which are enabled when an optional Intel® Remote Management Module 4 Lite (RMM4
Lite) is installed. The Intel® RMM4 add-on offers convenient, remote KVM access and control
through LAN and internet. It captures, digitizes, and compresses video and transmits it with
keyboard and mouse signals to and from a remote computer. Remote access and control
software runs in the integrated baseboard management controller, utilizing expanded
capabilities enabled by the Intel® RMM4 hardware.
Key Features of the RMM4 add-on are:
Revision 1.34
125
Platform Management
Technical Product Specification

KVM redirection from either the dedicated management NIC or the server board NICs
used for management traffic; up to two KVM sessions

Media Redirection – The media redirection feature is intended to allow system
administrators or users to mount a remote IDE or USB CDROM, floppy drive, or a USB
flash disk as a remote device to the server. Once mounted, the remote device appears
just like a local device to the server allowing system administrators or users to install
software (including operating systems), copy files, update BIOS, or boot the server
from this device.

KVM – Automatically senses video resolution for best possible screen capture, high
performance mouse tracking and synchronization. It allows remote viewing and
configuration in pre-boot POST and BIOS setup.
9.5.3.1
Keyboard, Video, Mouse (KVM) Redirection
The BMC firmware supports keyboard, video, and mouse redirection (KVM) over LAN. This
feature is available remotely from the embedded web server as a Java applet. This feature is
only enabled when the Intel® RMM4 lite is present. The client system must have a Java
Runtime Environment (JRE) version 6.0 or later to run the KVM or media redirection applets.
The BMC supports an embedded KVM application (Remote Console) that can be launched
from the embedded web server from a remote console. USB 1.1 or USB 2.0 based mouse and
keyboard redirection are supported. It is also possible to use the KVM-redirection (KVM-r)
session concurrently with media-redirection (media-r). This feature allows a user to
interactively use the keyboard, video, and mouse (KVM) functions of the remote server as if
the user were physically at the managed server. KVM redirection console supports the
following keyboard layouts: English, Dutch, French, German, Italian, Russian, and Spanish.
KVM redirection includes a “soft keyboard” function. The “soft keyboard” is used to simulate
an entire keyboard that is connected to the remote system. The “soft keyboard” functionality
supports the following layouts: English, Dutch, French, German, Italian, Russian, and Spanish.
The KVM-redirection feature automatically senses video resolution for best possible screen
capture and provides high-performance mouse tracking and synchronization. It allows remote
viewing and configuration in pre-boot POST and BIOS setup, once BIOS has initialized video.
Other attributes of this feature include:

Encryption of the redirected screen, keyboard, and mouse

Compression of the redirected screen

Ability to select a mouse configuration based on the OS type

Supports user definable keyboard macros
KVM redirection feature supports the following resolutions and refresh rates:

126
640x480 at 60Hz, 72Hz, 75Hz, 85Hz, 100Hz
Revision 1.34
Technical Product Specification

800x600 at 60Hz, 72Hz, 75Hz, 85Hz

1024x768 at 60Hz, 72Hz, 75Hz, 85Hz

1280x960 at 60Hz

1280x1024 at 60Hz

1600x1200 at 60Hz

1920x1080 (1080p)

1920x1200 (WUXGA)

1650x1080 (WSXGA+)
9.5.3.2
Remote Console
Platform Management
The Remote Console is the redirected screen, keyboard and mouse of the remote host system.
To use the Remote Console window of your managed host system, the browser must include a
Java* Runtime Environment plug-in. If the browser has no Java support, such as with a small
handheld device, the user can maintain the remote host system using the administration
forms displayed by the browser.
The Remote Console window is a Java Applet that establishes TCP connections to the BMC.
The protocol that is run over these connections is a unique KVM protocol and not HTTP or
HTTPS. This protocol uses ports #7578 for KVM, #5120 for CDROM media redirection, and
#5123 for Floppy/USB media redirection. When encryption is enabled, the protocol uses ports
#7582 for KVM, #5124 for CDROM media redirection, and #5127 for Floppy/USB media
redirection. The local network environment must permit these connections to be made, that is,
the firewall and, in case of a private internal network, the NAT (Network Address Translation)
settings have to be configured accordingly.
9.5.3.3
Performance
The remote display accurately represents the local display. The feature adapts to changes to
the video resolution of the local display and continues to work smoothly when the system
transitions from graphics to text or vice-versa. The responsiveness may be slightly delayed
depending on the bandwidth and latency of the network.
Enabling KVM and/or media encryption will degrade performance. Enabling video
compression provides the fastest response while disabling compression provides better video
quality.
For the best possible KVM performance, a 2Mb/sec link or higher is recommended.
The redirection of KVM over IP is performed in parallel with the local KVM without affecting
the local KVM operation.
9.5.3.4
Security
The KVM redirection feature supports multiple encryption algorithms, including RC4 and AES.
The actual algorithm that is used is negotiated with the client based on the client’s capabilities.
Revision 1.34
127
Platform Management
9.5.3.5
Technical Product Specification
Availability
The remote KVM session is available even when the server is powered-off (in stand-by mode).
No re-start of the remote KVM session shall be required during a server reset or power on/off.
A BMC reset (for example, due to a BMC Watchdog initiated reset or BMC reset after BMC
firmware update) will require the session to be re-established.
KVM sessions persist across system reset, but not across an AC power loss.
9.5.3.6
Usage
As the server is powered up, the remote KVM session displays the complete BIOS boot
process. The user is able to interact with BIOS setup, change and save settings as well as enter
and interact with option ROM configuration screens.
At least two concurrent remote KVM sessions are supported. It is possible for at least two
different users to connect to the same server and start remote KVM sessions.
9.5.3.7
Force-enter BIOS Setup
KVM redirection can present an option to force-enter BIOS Setup. This enables the system to
enter F2 setup while booting which is often missed by the time the remote console redirects
the video.
9.5.3.8
Media Redirection
The embedded web server provides a Java applet to enable remote media redirection. This
may be used in conjunction with the remote KVM feature, or as a standalone applet.
The media redirection feature is intended to allow system administrators or users to mount a
remote IDE or USB CD-ROM, floppy drive, or a USB flash disk as a remote device to the server.
Once mounted, the remote device appears just like a local device to the server, allowing
system administrators or users to install software (including operating systems), copy files,
update BIOS, and so on, or boot the server from this device.
The following capabilities are supported:
128

The operation of remotely mounted devices is independent of the local devices on the
server. Both remote and local devices are useable in parallel.

Either IDE (CD-ROM, floppy) or USB devices can be mounted as a remote device to the
server.

It is possible to boot all supported operating systems from the remotely mounted
device and to boot from disk IMAGE (*.IMG) and CD-ROM or DVD-ROM ISO files. See
the Tested/supported Operating System List for more information.

Media redirection supports redirection for both a virtual CD device and a virtual
Floppy/USB device concurrently. The CD device may be either a local CD drive or else
an ISO image file; the Floppy/USB device may be either a local Floppy drive, a local
USB device, or else a disk image file.
Revision 1.34
Technical Product Specification
Platform Management

The media redirection feature supports multiple encryption algorithms, including RC4
and AES. The actual algorithm that is used is negotiated with the client based on the
client’s capabilities.

A remote media session is maintained even when the server is powered-off (in
standby mode). No restart of the remote media session is required during a server
reset or power on/off. A BMC reset (for example, due to a BMC reset after BMC
firmware update) will require the session to be re-established.

The mounted device is visible to (and useable by) managed system’s OS and BIOS in
both pre-boot and post-boot states.

The mounted device shows up in the BIOS boot order and it is possible to change the
BIOS boot order to boot from this remote device.

It is possible to install an operating system on a bare metal server (no OS present)
using the remotely mounted device. This may also require the use of KVM-r to
configure the OS during installation.
USB storage devices will appear as floppy disks over media redirection. This allows for the
installation of device drivers during OS installation.
If either a virtual IDE or virtual floppy device is remotely attached during system boot, both the
virtual IDE and virtual floppy are presented as bootable devices. It is not possible to present
only a single-mounted device type to the system BIOS.
9.5.3.8.1 Availability
The default inactivity timeout is 30 minutes and is not user-configurable. Media redirection
sessions persist across system reset but not across an AC power loss or BMC reset.
9.5.3.8.2 Network Port Usage
The KVM and media redirection features use the following ports:

5120 – CD Redirection

5123 – FD Redirection

5124 – CD Redirection (Secure)

5127 – FD Redirection (Secure)

7578 – Video Redirection

7582 – Video Redirection (Secure)
For additional information, reference the Intel® Remote Management Module 4 and Integrated
BMC Web Console Users Guide.
Revision 1.34
129
Thermal Management
Technical Product Specification
10 Thermal Management
The compute module is designed to operate at external ambient temperatures of between
10ºC and 35ºC with limited excursion based operation up to 45ºC. Working with integrated
platform management, several features within the compute module are designed to move air
in a front-to-back direction, through the compute module and over critical components to
prevent them from overheating and allow the system to operate with best performance.
Figure 46. Air Flow and Fan Identification
The following table provides air flow data associated with the different product models within
this product family, and is provided for reference purposes only. The data was derived from
actual wind tunnel test methods and measurements using fully configured system
configurations. Lesser system configurations may produce slightly different data results. As
such, the CFM data provided using server management utilities that utilize platform sensor
data, may vary from the data listed in the table.
Table 65. Air Flow
With Intel® Server Chassis H2312XXKR2/LR2
Single Compute Module Airflow
6 ~ 30CFM
With Intel® Server Chassis H2216XXKR2/LR2
5 ~ 41CFM
The compute module supports short-term, excursion-based, operation up to 45°C (ASHRAE
A4) with limited performance impact. The configuration requirements and limitations are
described in the configuration matrix found in the Power Budget and Thermal Configuration
Tool, available as a download online at http://www.intel.com/support.
130
Revision 1.34
Technical Product Specification
Thermal Management
The installation and functionality of several components are used to maintain compute
module thermals. They include three compute module fans, air duct, and installed CPU heat
sinks.
To keep the compute module operating within supported maximum thermal limits, the
compute module must meet the following operating and configuration guidelines:

The compute module operating ambient is designed for sustained operation up to
35ºC (ASHRAE Class A2) with short-term excursion-based operation up to 45ºC
(ASHRAE Class A4).
o
The compute module can operate up to 40ºC (ASHRAE Class A3) for up to 900
hours per year.
o
The compute module can operate up to 45ºC (ASHRAE Class A4) for up to 90
hours per year.
o
The compute module performance may be impacted when operating within the
extended operating temperature range.
o
There is no long-term system reliability impact when operating at the extended
temperature range within the approved limits.

Specific configuration requirements and limitations are documented in the
configuration matrix found in the Power Budget and Thermal Configuration Tool,
available as a download online at http://www.intel.com/support.

The CPU-1 processor + CPU heat sink must be installed first. The CPU-2 heat sink
must be installed at all times, with or without a processor installed.

Memory Slot population requirements –

o
DIMM Population Rules on CPU-1 – Install DIMMs in order; Channels A, B, C, and
D.
o
DIMM Population Rules on CPU-2 – Install DIMMs in order; Channels E, F, G, and
H.
With the compute module operating, the air duct must be installed at all times.
Revision 1.34
131
System Security
Technical Product Specification
11 System Security
The server board supports a variety of system security options designed to prevent
unauthorized system access or tampering of server settings. System security options
supported include:

Password Protection

Front Panel Lockout
The <F2> BIOS Setup Utility, accessed during POST, includes a Security tab where options to
configure passwords, and front panel lockout can be found.
Main
Advanced
Security
Server Management
Boot Options
Administrator Password Status
<Installed/Not Installed>
User Password Status
<Installed/Not Installed>
Set Administrator Password
[123aBcDeFgH$#@]
Set User Password
[123aBcDeFgH$#@]
Power On Password
Enabled/Disabled
Front Panel Lockout
Enabled/Disabled
Boot Manager
11.1 Password Setup
The BIOS uses passwords to prevent unauthorized access to the server. Passwords can restrict
entry to the BIOS Setup utility, restrict use of the Boot Device popup menu during POST,
suppress automatic USB device re-ordering, and prevent unauthorized system power on. It is
strongly recommended that an Administrator Password be set. A system with no
Administrator password set allows anyone who has access to the server to change BIOS
settings.
An Administrator password must be set in order to set the User password.
The maximum length of a password is 14 characters and can be made up of a combination of
alphanumeric (a-z, A-Z, 0-9) characters and any of the following special characters:
! @ # $ % ^ & * ( ) - _ + = ?
Passwords are case sensitive.
132
Revision 1.34
Technical Product Specification
System Security
The Administrator and User passwords must be different from each other. An error message
will be displayed and a different password must be entered if there is an attempt to enter the
same password for both. The use of “Strong Passwords” is encouraged, but not required. In
order to meet the criteria for a strong password, the password entered must be at least 8
characters in length, and must include at least one each of alphabetic, numeric, and special
characters. If a weak password is entered, a warning message will be displayed, and the weak
password will be accepted.
Once set, a password can be cleared by changing it to a null string. This requires the
Administrator password, and must be done through BIOS Setup or other explicit means of
changing the passwords. Clearing the Administrator password will also clear the User
password. Passwords can also be cleared by using the Password Clear jumper on the server
board. See Chapter 7 – Configuration Jumpers.
Resetting the BIOS configuration settings to default values (by any method) has no effect on
the Administrator and User passwords.
As a security measure, if a User or Administrator enters an incorrect password three times in a
row during the boot sequence, the system is placed into a halt state. A system reset is required
to exit out of the halt state. This feature makes it more difficult to guess or break a password.
In addition, on the next successful reboot, the Error Manager displays a Major Error code
0048, which also logs a SEL event to alert the authorized user or administrator that a
password access failure has occurred.
11.1.1
System Administrator Password Rights
When the correct Administrator password is entered when prompted, the user has the ability
to perform the following:

Access the <F2> BIOS Setup Utility.

Has the ability to configure all BIOS setup options in the <F2> BIOS Setup Utility.

Has the ability to clear both the Administrator and User passwords.

Access the <F6> Boot Menu during POST.

If the Power On Password function is enabled in BIOS Setup, the BIOS will halt early in
POST to request a password (Administrator or User) before continuing POST.
11.1.2
Authorized System User Password Rights and Restrictions
When the correct User password is entered, the user has the ability to perform the following:

Access the <F2> BIOS Setup Utility.

View, but not change any BIOS Setup options in the <F2> BIOS Setup Utility.

Modify System Time and Date in the BIOS Setup Utility.

If the Power On Password function is enabled in BIOS Setup, the BIOS will halt early in
POST to request a password (Administrator or User) before continuing POST.
Revision 1.34
133
System Security
Technical Product Specification
In addition to restricting access to most Setup fields to viewing only when a User password is
entered, defining a User password imposes restrictions on booting the system. In order to
simply boot in the defined boot order, no password is required. However, the F6 Boot popup
menu prompts for a password, and can only be used with the Administrator password. Also,
when a User password is defined, it suppresses the USB Reordering that occurs, if enabled,
when a new USB boot device is attached to the system. A User is restricted from booting in
anything other than the Boot Order defined in the Setup by an Administrator.
11.2 Front Panel Lockout
If enabled in BIOS setup, this option disables the following front panel features:

The OFF function of the Power button

System Reset button
If [Enabled] is selected, system power off and reset must be controlled via a system
management interface.
11.3 Trusted Platform Module (TPM) support
The BBS2600KPTR server board has the option to support a Trusted Platform Module (TPM).
A TPM is a hardware-based security device that addresses the growing concern on boot
process integrity and offers better data protection. TPM protects the system start-up process
by ensuring it is tamper-free before releasing system control to the operating system. A TPM
device provides secured storage to store data, such as security keys and passwords. In
addition, a TPM device has encryption and hash functions. The server board implements TPM
as per TPM PC Client specifications revision 1.2 by the Trusted Computing Group (TCG).
A TPM device is secured from external software attacks and physical theft. A pre-boot
environment, such as the BIOS and operating system loader, uses the TPM to collect and store
unique measurements from multiple factors within the boot process to create a system
fingerprint. This unique fingerprint remains the same unless the pre-boot environment is
tampered with. Therefore, it is used to compare to future measurements to verify the integrity
of the boot process.
After the system BIOS completes the measurement of its boot process, it hands off control to
the operating system loader and in turn to the operating system. If the operating system is
TPM-enabled, it compares the BIOS TPM measurements to those of previous boots to make
sure the system was not tampered with before continuing the operating system boot process.
Once the operating system is in operation, it optionally uses TPM to provide additional system
and data security.
134
Revision 1.34
Technical Product Specification
System Security
11.3.1 TPM security BIOS
The BIOS TPM support conforms to the TPM PC Client Implementation Specification for
Conventional BIOS, the TPM Interface Specification, and the Microsoft Windows BitLocker*
Requirements. The role of the BIOS for TPM security includes the following:
Measures and stores the boot process in the TPM microcontroller to allow a TPM enabled
operating system to verify system boot integrity.

Produces EFI and legacy interfaces to a TPM-enabled operating system for using TPM.

Produces ACPI TPM device and methods to allow a TPM-enabled operating system to
send TPM administrative command requests to the BIOS.

Verifies operator physical presence. Confirms and executes operating system TPM
administrative command requests.

Provides BIOS Setup options to change TPM security states and to clear TPM
ownership.
For additional details, refer to the TCG PC Client Specific Implementation Specification, the
TCG PC Client Specific Physical Presence Interface Specification, and the Microsoft BitLocker*
Requirement documents.
11.3.2 Physical presence
Administrative operations to the TPM require TPM ownership or physical presence indication
by the operator to confirm the execution of administrative operations. The BIOS implements
the operator presence indication by verifying the setup Administrator password.
A TPM administrative sequence invoked from the operating system proceeds as follows:
1. User makes a TPM administrative request through the operating system’s security
software.
2. The operating system requests the BIOS to execute the TPM administrative command
through TPM ACPI methods and then resets the system.
3. The BIOS verifies the physical presence and confirms the command with the operator.
4. The BIOS executes TPM administrative command(s), inhibits BIOS Setup entry and boots
directly to the operating system which requested the TPM command(s).
11.3.3 TPM security setup options
The BIOS TPM Setup allows the operator to view the current TPM state and to carry out
rudimentary TPM administrative operations. Performing TPM administrative options through
the BIOS setup requires TPM physical presence verification. TPM administrative options are
only shown in the Security Menu screen when a TPM is physically installed on the board.
Revision 1.34
135
System Security
Technical Product Specification
Using BIOS TPM Setup, the operator can turn ON or OFF TPM functionality and clear the TPM
ownership contents. After the requested TPM BIOS Setup operation is carried out, the option
reverts to No Operation.
The BIOS TPM Setup also displays the current state of the TPM, whether TPM is enabled or
disabled and activated or deactivated. Note that while using TPM, a TPM-enabled operating
system or application may change the TPM state independent of the BIOS setup. When an
operating system modifies the TPM state, the BIOS Setup displays the updated TPM state.
The BIOS Setup TPM Clear option allows the operator to clear the TPM ownership key and
allows the operator to take control of the system with TPM. You use this option to clear
security settings for a newly initialized system or to clear a system for which the TPM
ownership security key was lost.
Table 66. TPM Setup Utility – Security Configuration Screen Fields
Setup Item
Options
Help Text
TPM State
Enabled and Activated
Information only.
Enabled and Deactivated
Shows the current TPM device state.
Disabled and Activated
A disabled TPM device will not
execute commands that use TPM
functions and TPM security
operations will not be available.
Disabled and Deactivated
Comments
An enabled and deactivated TPM is
in the same state as a disabled TPM
except setting of TPM ownership is
allowed if not present already.
An enabled and activated TPM
executes all commands that use TPM
functions and TPM security
operations will be available.
TPM
Administrative
Control
No Operation
Turn On
Turn Off
Clear Ownership
[No Operation] - No changes to
current state.
[Turn On] - Enables and activates
TPM.
Any Administrative Control operation
selected will require the system to
perform a Hard Reset in order to
become effective.
[Turn Off] - Disables and
deactivates TPM.
[Clear Ownership] - Removes the
TPM ownership authentication
and returns the TPM to a factory
default state.
Note: The BIOS setting returns to
[No Operation] on every boot
cycle by default.
136
Revision 1.34
Technical Product Specification
Environmental Limits Specification
12 Environmental Limits Specification
Operation of the server board at conditions beyond those shown in the following table may
cause permanent damage to the system. Exposure to absolute maximum rating conditions for
extended periods may affect long term system reliability.
Note: The Energy Star compliance is at system level, but not board level. Use of Intel boards
alone does not guarantee Energy Star compliance.
Table 67. Server Board Design Specifications
Parameter
Limits
Operating Temperature
+10°C to +35°C with the maximum rate of change not to
exceed 10°C per hour.
Non-Operating Temperature
-40°C to +70°C
Non-Operating Humidity
90%, non-condensing at 35°C
Acoustic noise
Sound power: 7.0BA with hard disk drive stress only at
room ambient temperature (23 +/-2°C)
Shock, operating
Half sine, 2g peak, 11 mSec
Shock, unpackaged
Trapezoidal, 25g, velocity change 205 inches/second (80
lbs. to < 100 lbs.)
Vibration, unpackaged
5 Hz to 500 Hz, 2.20 g RMS random
Shock and vibration, packaged
ISTA (International Safe Transit Association) Test
Procedure 3A
ESD
+/-12 KV except I/O port +/- 8 KV per Intel® Environmental
Test Specification
System Cooling Requirement in BTU/Hr.
1600 Watt Max – 5459 BTU/hour
System Cooling Requirement in BTU/Hr.
2130 Watt Max – 7268 BTU/hour
Disclaimer Note: Intel ensures the unpackaged server board and system meet the shock
requirement mentioned above through its own chassis development and system configuration.
It is the responsibility of the system integrator to determine the proper shock level of the board
and system if the system integrator chooses different system configuration or different chassis.
Intel Corporation cannot be held responsible if components fail or the server board does not
operate correctly when used outside any of its published operating or non-operating limits.
Revision 1.34
137
Power Supply Specification Guidelines
Technical Product Specification
13 Power Supply Specification Guidelines
This section provides power supply specification guidelines recommended for providing the
specified server platform with stable operating power requirements.
Note: The power supply data provided in this section is for reference purposes only. It reflects
Intel’s own DC power out requirements for a 1200W, 1600W and 2130W power supply as used
in an Intel designed 2U server platform. The intent of this section is to provide customers with a
guide to assist in defining and/or selecting a power supply for custom server platform designs
that utilize the server boards detailed in this document.
13.1 Power Supply DC Output Connector
The server board includes two main power Minifit Jr* connectors allowing for power supplies
to attach directly to the server board. The connectors are two sets of 2x3 pin and can be used
to deliver 12amps per pin or 60+Amps total. Note that no over-voltage protective circuits will
exist on the board.
Table 68. Power Supply DC Power Input Connector Pin-out
Pin
1
Signal Name
+12V
Pin
4
Signal Name
GND
2
+12V
5
GND
3
+12V
6
GND
13.2 Power Supply DC Output Specification
13.2.1 Output Power/Currents
The following table defines the minimum power and current ratings. The power supply must
meet both static and dynamic voltage regulation requirements for all conditions.
Table 69. Minimum 1200W/1600W Load Ratings
Parameter
12V main
Min
0.0
Max.
60.0
Peak 1, 2
72.0
Unit
A
5Vstby
0.0
2.0
2.4
A
Table 70. Minimum 2130W Load Ratings
Notes:
1.
138
Parameter
12V main (240 – 264 VAC)
Min
0.0
Max.
178.0
Peak
210.0
Unit
A
12V stby
0.0
3.5
4.0
A
Peak combined power for all outputs shall not exceed 800W.
Revision 1.34
Technical Product Specification
2.
3.
4.
5.
6.
Power Supply Specification Guidelines
12Vstby must be able to provide 4.0A peak load with single power supply. The power supply fan is allowed
to run in standby mode for loads > 1.5A.
Length of time peak power can be supported is based on thermal sensor and assertion of the SMBAlert#
signal. Minimum peak power duration shall be 20 seconds without asserting the SMBAlert# signal. The
peak load requirement should apply to full operating temperature range.
The setting of IPeak < IOCW < IOCP needs to be followed to make the CLST work reasonably.
Power supply must protect itself in case system doesn't take any action to reduce load based on SMBAlert#
signal asserting.
The power supply shall support 25msec peak power at 20% duty cycle step loading for an average current
at the current rating.
13.2.2 Standby Output
The 5VSB (12VSB for the 2130W PSU) output shall be present when an AC input greater than
the power supply turn on voltage is applied. There should be load sharing in the standby rail.
13.2.3 Voltage Regulation
The power supply output voltages must stay within the following voltage limits when
operating at steady state and dynamic loading conditions. These limits include the peak-peak
ripple/noise. These shall be measured at the output connectors.
Table 71. Voltage Regulation Limits
Parameter
+12V
Tolerance
- 5%/+5%
Min
+11.40
Nom
+12.00
Max
+12.60
Units
Vrms
+5V stby
- 5%/+5%
+4.75
+5.00
+5.25
Vrms
+12V stby (2130W)
- 5%/+5%
+11.40
+12.00
+12.60
Vrms
13.2.4 Dynamic Loading
The output voltages shall remain within limits specified for the step loading and capacitive
loading specified in the following table. The load transient repetition rate shall be tested
between 50Hz and 5 kHz at duty cycles ranging from 10%-90%. The load transient repetition
rate is only a test specification. The  step load may occur anywhere within the MIN load to the
MAX load conditions.
Table 72. Transient Load Requirements
Output
+5VSB
 Step Load Size
1.0A
Load Slew Rate
0.25 A/sec
Test capacitive Load
20 F
+12VSB
1.0A
0.25 A/sec
20 F
+12V
60% of max load
0.25 A/sec
2000 F
Note: For dynamic condition +12V min loading is 1A.
13.2.5 Capacitive Loading
The power supply shall be stable and meet all requirements with the following capacitive
loading ranges.
Revision 1.34
139
Power Supply Specification Guidelines
Technical Product Specification
Table 73. Capacitive Loading Conditions
Output
+5VSB
MIN
20
MAX
3100
Units
F
+12VSB
20
3100
F
+12V
500
25000
F
13.2.6 Grounding
The output ground of the pins of the power supply provides the output power return path.
The output connector ground pins shall be connected to the safety ground (power supply
enclosure). This grounding should be well designed to ensure passing the max allowed
Common Mode Noise levels.
The power supply shall be provided with a reliable protective earth ground. All secondary
circuits shall be connected to protective earth ground. Resistance of the ground returns to
chassis shall not exceed 1.0 m. This path may be used to carry DC current.
13.2.7 Closed-loop Stability
The power supply shall be unconditionally stable under all line/load/transient load conditions
including specified capacitive load ranges. A minimum of 45 degrees phase margin and 10dBgain margin is required. Closed-loop stability must be ensured at the maximum and minimum
loads as applicable.
13.2.8 Residual Voltage Immunity in Standby Mode
The power supply should be immune to any residual voltage placed on its outputs (Typically a
leakage voltage through the system from standby output) up to 500mV. There shall be no
additional heat generated, nor stressing of any internal components with this voltage applied
to any individual or all outputs simultaneously. It also should not trip the protection circuits
during turn on.
The residual voltage at the power supply outputs for no load condition shall not exceed
100mV when AC voltage is applied and the PSON# signal is de-asserted.
13.2.9 Common Mode Noise
The Common Mode noise on any output shall not exceed 350mV pk-pk over the frequency
band of 10Hz to 20MHz.
13.2.10
Soft Starting
The Power Supply shall contain control circuit which provides monotonic soft start for its
outputs without overstress of the AC line or any power supply components at any specified
AC line or load conditions.
140
Revision 1.34
Technical Product Specification
13.2.11
Power Supply Specification Guidelines
Zero Load Stability Requirements
When the power subsystem operates in a no load condition, it does not need to meet the
output regulation specification, but it must operate without any tripping of over-voltage or
other fault circuitry. When the power subsystem is subsequently loaded, it must begin to
regulate and source current without fault.
13.2.12
Hot Swap Requirements
Hot swapping a power supply is the process of inserting and extracting a power supply from
an operating power system. During this process the output voltages shall remain within the
limits with the capacitive load specified. The hot swap test must be conducted when the
system is operating under static, dynamic, and zero loading conditions.
13.2.13
Forced Load Sharing
The +12V output will have active load sharing. The output will share within 10% at full load.
The failure of a power supply should not affect the load sharing or output voltages of the
other supplies still operating. The supplies must be able to load share in parallel and operate
in a hot-swap/redundant 1+1 configurations. The 12VSBoutput is not required to actively
share current between power supplies (passive sharing). The 12VSBoutput of the power
supplies are connected together in the system so that a failure or hot swap of a redundant
power supply does not cause these outputs to go out of regulation in the system.
13.2.14
Ripple/Noise
The maximum allowed ripple/noise output of the power supply is defined in the following
table. This is measured over a bandwidth of 10Hz to 20MHz at the power supply output
connectors. A 10F tantalum capacitor in parallel with a 0.1F ceramic capacitor is placed at
the point of measurement.
Table 74. Ripples and Noise
+12V main
120mVp-p
13.2.15
+5VSB
50mVp-p
+12VSB
120mVp-p
Timing Requirement
These are the timing requirements for the power supply operation. The output voltages must
rise from 10% to within regulation limits (Tvout_rise) within 5 to 70ms. For 5VSB, it is allowed to
rise from 1.0 to 25ms. All outputs must rise monotonically. The following table shows the
timing requirements for the power supply being turned on and off through the AC input, with
PSON held low and the PSON signal, with the AC input applied.
Revision 1.34
141
Power Supply Specification Guidelines
Technical Product Specification
Table 75. Timing Requirements
Item
Tvout_rise
Output voltage rise time
Description
Min
5.0 *
Max
70 *
Units
ms
Tsb_on_delay
Tac_on_delay
Delay from AC being applied to 5VSB being within regulation.
1500
ms
Delay from AC being applied to all output voltages being
within regulation.
3000
ms
Tvout_holdup
Time 12Vl output voltage stay within regulation after loss of
AC.
13
ms
Tpwok_holdup
Delay from loss of AC to de-assertion of PWOK
12
ms
Tpson_on_delay
Delay from PSON# active to output voltages within regulation
limits.
5
Tpson_pwok
Delay from PSON# deactivate to PWOK being de-asserted.
Tpwok_on
Delay from output voltages within regulation limits to PWOK
asserted at turn on.
100
Tpwok_off
Delay from PWOK de-asserted to output voltages dropping
out of regulation limits.
1
ms
Tpwok_low
Duration of PWOK being in the de-asserted state during an
off/on cycle using AC or the PSON signal.
100
ms
Tsb_vout
Delay from 5VSB being in regulation to O/Ps being in
regulation at AC turn on.
50
T5VSB_holdup
Time the 5VSB output voltage stays within regulation after
loss of AC.
70
400
ms
5
ms
500
ms
1000
ms
ms
Note:
* The 5VSB output voltage rise time shall be from 1.0ms to 25ms.
142
Revision 1.34
Technical Product Specification
Power Supply Specification Guidelines
Table 76. Timing Requirements (12VSB)
Item
Tvout_rise
Description
Output voltage rise time
Min
5.0 *
Max
70 *
Units
ms
Tsb_on_delay
Delay from AC being applied to 12VSB being within
regulation.
1500
ms
Tac_on_delay
Delay from AC being applied to all output voltages being
within regulation.
3000
ms
Tvout_holdup
Time 12V output voltage stay within regulation after loss of
AC.
11
Tpwok_holdup
Delay from loss of AC to de-assertion of PWOK
10
Tpson_on_delay
Delay from PSON# active to output voltages within regulation
limits.
5
Tpson_pwok
Delay from PSON# deactivate to PWOK being de-asserted.
Tpwok_on
Delay from output voltages within regulation limits to PWOK
asserted at turn on.
100
Tpwok_off
Delay from PWOK de-asserted to output voltages dropping
out of regulation limits.
1
ms
Tpwok_low
Duration of PWOK being in the de-asserted state during an
off/on cycle using AC or the PSON signal.
100
ms
Tsb_vout
Delay from 12VSB being in regulation to O/Ps being in
regulation at AC turn on.
50
T12VSB_holdup
Time the 12VSB output voltage stays within regulation after
loss of AC.
70
ms
ms
400
ms
5
ms
500
ms
1000
ms
ms
Note:
* The 12VSB output voltage rise time shall be from 5.0ms to 10ms.
Revision 1.34
143
Power Supply Specification Guidelines
Technical Product Specification
AC Input
Tvout_holdup
Vout
Tpwok_low
TAC_on_delay
Tsb_on_delay
Tpwok_on
PWOK
12Vsb
Tpwok_off
Tsb_on_delay
Tpwok_on
Tpson_pwok
Tpwok_holdup
Tsb_vout
Tpwok_off
T5Vsb_holdup
Tpson_on_delay
PSON
AC turn on/off cycle
PSON turn on/off cycle
Figure 47. Turn On/Off Timing (Power Supply Signals – 5VSB)
Figure 48. Turn On/Off Timing (Power Supply Signals – 12VSB)
144
Revision 1.34
Technical Product Specification
Appendix A: Integration and Usage Tips
Appendix A: Integration and Usage Tips

When adding or removing components or peripherals from the server board, AC power
must be removed. With AC power plugged into the server board, 5V standby is still
present even though the server board is powered off.

This server board supports the Intel® Xeon® Processor E5-2600 v3/v4 product family
with a Thermal Design Power (TDP) of up to and including 160 Watts. Previous
generations of the Intel® Xeon® processors are not supported.

Processors must be installed in order. CPU 1 must be populated for the server board to
operate.

On the back edge of the server board are eight diagnostic LEDs that display a sequence
of amber POST codes during the boot process. If the server board hangs during POST,
the LEDs display the last POST event run before the hang.

For the best performance, the number of DIMMs installed should be balanced across
both processor sockets and memory channels. For example, a two-DIMM configuration
performs better than a one-DIMM configuration. In a two-DIMM configuration, DIMMs
should be installed in DIMM sockets A1 and D1. A six-DIMM configuration (DIMM
sockets A1, B1, C1, D1, E1, and F1) performs better than a three-DIMM configuration
(DIMM sockets A1, B1, and C1).

Normal Integrated BMC functionality is disabled with the BMC Force Update jumper set
to the “enabled” position (pins 2-3). The server should never be run with the BMC
Force Update jumper set in this position and should only be used when the standard
firmware update process fails. This jumper should remain in the default (disabled)
position (pins 1-2) when the server is running normally.

When performing a normal BIOS update procedure, the BIOS recovery jumper must be
set to its default position (pins 1-2).
Revision 1.34
145
Appendix B: Integrated BMC Sensor Tables
Technical Product Specification
Appendix B: Integrated BMC Sensor Tables
This appendix lists the sensor identification numbers and information about the sensor type,
name, supported thresholds, assertion and de-assertion information, and a brief description
of the sensor purpose. See the Intelligent Platform Management Interface Specification,
Version 2.0, for sensor and event/reading-type table information.

Sensor Type
The sensor type references the values in the Sensor Type Codes table in the Intelligent
Platform Management Interface Specification Second Generation v2.0. It provides a
context to interpret the sensor.

Event/Reading Type
The event/reading type references values from the Event/Reading Type Code Ranges
and the Generic Event/Reading Type Code tables in the Intelligent Platform
Management Interface Specification Second Generation v2.0. Digital sensors are
specific type of discrete sensors that only have two states.

Event Thresholds/Triggers
The following event thresholds are supported for threshold type sensors:
[u,l][nr,c,nc] upper non-recoverable, upper critical, upper non-critical, lower nonrecoverable, lower critical, lower non-critical uc, lc upper critical, lower critical
Event triggers are supported event-generating offsets for discrete type sensors. The
offsets can be found in the Generic Event/Reading Type Code or Sensor Type Code
tables in the Intelligent Platform Management Interface Specification Second
Generation v2.0, depending on whether the sensor event/reading type is generic or a
sensor-specific response.

Assertion/Deassertion
Assertion and de-assertion indicators reveal the type of events this sensor generates:
As: Assertion
De: De-assertion

Readable Value/Offsets
Readable value indicates the type of value returned for threshold and other nondiscrete type sensors.
Readable offsets indicate the offsets for discrete sensors that are readable by means of
the Get Sensor Reading command. Unless otherwise indicated, event triggers are
readable. Readable offsets consist of the reading type offsets that do not generate
events.

Event Data
Event data is the data that is included in an event message generated by the associated
sensor. For threshold-based sensors, these abbreviations are used:
R: Reading value
T: Threshold value

146
Rearm Sensors
Revision 1.34
Technical Product Specification
Appendix B: Integrated BMC Sensor Tables
The rearm is a request for the event status for a sensor to be rechecked and updated
upon a transition between good and bad states. Rearming the sensors can be done
manually or automatically. This column indicates the type supported by the sensor.
The following abbreviations are used in the comment column to describe a sensor:
A: Auto-rearm
M: Manual rearm
I: Rearm by init agent

Default Hysteresis
The hysteresis setting applies to all thresholds of the sensor. This column provides the
count of hysteresis for the sensor, which can be 1 or 2 (positive or negative hysteresis).

Criticality
Criticality is a classification of the severity and nature of the condition. It also controls
the behavior of the front panel status LED.

Standby
Some sensors operate on standby power. These sensors may be accessed and/or
generate events when the main (system) power is off, but AC power is present.
Revision 1.34
147
Appendix B: Integrated BMC Sensor Tables
Technical Product Specification
Note: All sensors listed below may not be present on all platforms. Please reference the BMC EPS for platform applicability.
Redundancy sensors will only be present on systems with appropriate hardware to support redundancy (for instance, fan or power
supply).
Table 77. BMC Sensor Table
Full Sensor Name
(Sensor name in SDR)
Power Unit Status
(Pwr Unit Status)
Senso
r#
01h
Platform
Applicabilit
y
All
Sensor Type
Power Unit
09h
Event/Rea
ding Type
Sensor
Specific
6Fh
Event Offset Triggers
Contrib. To
System Status
00 - Power down
OK
02 - 240 VA power
down
Fatal
04 - A/C lost
OK
05 - Soft power
control failure
Fatal
Assert
/Deassert
Readable
Value/
Offsets
As
and
De
–
As
–
Event
Data
Rearm
Standby
Trig
Offset
A
X
Trig
Offset
M
X
06 - Power unit failure
Power Unit Redundancy1
(Pwr Unit Redund)
148
02h
Chassisspecific
Power Unit
Generic
09h
0Bh
00 - Fully Redundant
OK
01 - Redundancy lost
Degraded
02 - Redundancy
degraded
Degraded
03 - Non-redundant:
sufficient resources.
Transition from full
redundant state.
Degraded
04 – Non-redundant:
sufficient resources.
Transition from
insufficient state.
Degraded
05 - Non-redundant:
insufficient resources
Fatal
06 – Redundant:
degraded from fully
redundant state.
Degraded
07 – Redundant:
Transition from nonredundant state.
Degraded
Revision 1.34
Technical Product Specification
Full Sensor Name
(Sensor name in SDR)
Senso
r#
Appendix B: Integrated BMC Sensor Tables
Platform
Applicabilit
y
Sensor Type
Event/Rea
ding Type
Event Offset Triggers
Contrib. To
System Status
Assert
/Deassert
Readable
Value/
Offsets
OK
As
–
Degraded
Event
Data
Rearm
Standby
Trig
Offset
A
X
–
Trig
Offset
A
X
00 - Timer expired,
status only
IPMI Watchdog
(IPMI Watchdog)
03h
All
Watchdog 2
23h
Sensor
Specific
6Fh
01 - Hard reset
02 - Power down
03 - Power cycle
08 - Timer interrupt
Physical Security
(Physical Scrty)
FP Interrupt
(FP NMI Diag Int)
SMI Timeout
(SMI Timeout)
System Event Log
(System Event Log)
System Event
(System Event)
Button Sensor
(Button)
BMC Watchdog
Revision 1.34
04h
05h
06h
07h
Chassis
Intrusion is
chassisspecific
Chassis specific
All
All
Physical
Security
Sensor
Specific
00 - Chassis intrusion
05h
6Fh
04 - LAN leash lost
OK
As
and
De
Critical
Interrupt
Sensor
Specific
OK
As
–
Trig
Offset
A
–
13h
6Fh
00 - Front panel
NMI/diagnostic
interrupt
SMI Timeout
Digital
Discrete
01 – State asserted
Fatal
As
and
De
–
Trig
Offset
A
–
02 - Log area
reset/cleared
OK
As
–
Trig
Offset
A
X
04 – PEF action
OK
As
-
Trig
Offset
A
X
OK
AS
_
Trig
Offset
A
X
Degraded
As
–
Trig
Offset
A
-
F3h
Event Logging
Disabled
Sensor
Specific
10h
6Fh
System Event
Sensor
Specific
08h
All
12h
09h
All
Button/Switch
14h
0Ah
All
03h
6Fh
Sensor
Specific
6Fh
Mgmt System
Health
Digital
Discrete
28h
03h
00 – Power Button
02 – Reset Button
01 – State Asserted
149
Appendix B: Integrated BMC Sensor Tables
Full Sensor Name
(Sensor name in SDR)
Voltage Regulator Watchdog
(VR Watchdog)
Fan Redundancy1
(Fan Redundancy)
SSB Thermal Trip
(SSB Therm Trip)
IO Module Presence
(IO Mod Presence)
SAS Module Presence
(SAS Mod Presence)
150
Senso
r#
Platform
Applicabilit
y
0Bh
All
0Ch
0Dh
0Eh
0Fh
Chassisspecific
All
Technical Product Specification
Sensor Type
Voltage
02h
Event/Rea
ding Type
Digital
Discrete
Generic
04h
0Bh
01h
Platformspecific
Module/Board
Platformspecific
Module/Board
15h
15h
Contrib. To
System Status
Assert
/Deassert
Readable
Value/
Offsets
Rearm
Standby
01 – State Asserted
Fatal
As
and
De
–
Trig
Offset
M
X
00 - Fully redundant
OK
01 - Redundancy lost
Degraded
02 - Redundancy
degraded
Degraded
03 - Non-redundant:
Sufficient resources.
Transition from
redundant
Degraded
04 - Non-redundant:
Sufficient resources.
Transition from
insufficient.
Degraded
As
and
De
–
Trig
Offset
A
–
05 - Non-redundant:
insufficient resources.
Non-Fatal
06 – Non-Redundant:
degraded from fully
redundant.
Degraded
07 - Redundant
degraded from nonredundant
Degraded
01 – State Asserted
Fatal
As
and
De
–
Trig
Offset
M
X
01 – Inserted/Present
OK
As
and
De
–
Trig
Offset
M
-
01 – Inserted/Present
OK
As
and
De
–
Trig
Offset
M
X
03h
Fan
Temperature
Event Offset Triggers
Digital
Discrete
03h
Digital
Discrete
08h
Digital
Discrete
08h
Event
Data
Revision 1.34
Technical Product Specification
Full Sensor Name
(Sensor name in SDR)
BMC Firmware Health
(BMC FW Health)
System Airflow
(System Airflow)
Appendix B: Integrated BMC Sensor Tables
Senso
r#
Platform
Applicabilit
y
10h
All
11h
All
Sensor Type
Mgmt Health
28h
Event/Rea
ding Type
Sensor
Specific
Event Offset Triggers
Assert
/Deassert
Readable
Value/
Offsets
As
-
–
–
OK
01 – Inserted/Present
OK
[u,l] [c,nc]
nc =
Degraded
04 – Sensor Failure
Contrib. To
System Status
Degraded
Rearm
Standby
Trig
Offset
A
X
Analog
–
–
–
As
_
Trig
Offset
A
_
As
and
De
–
Trig
Offset
M
-
As
and
De
Analog
R, T
A
X
As
and
De
Analog
R, T
A
X
As
and
De
Analog
R, T
A
X
As
and
De
Analog
R, T
A
X
As
and
De
Analog
R, T
A
X
As
and
De
Analog
R, T
A
X
6Fh
Other Units
Threshold
0Bh
01h
–
Event
Data
00h – Update started
FW Update Status
12h
Version Change
2Bh
OEM
defined
70h
Platformspecific
Module/Board
Digital
Discrete
Platformspecific
Temperature
Threshold
01h
01h
Platformspecific
Temperature
Threshold
01h
01h
Platformspecific
Temperature
Threshold
01h
01h
Platformspecific
Temperature
Threshold
01h
01h
Platformspecific
Temperature
Threshold
01h
01h
Platformspecific
Temperature
Threshold
01h
01h
All
01h – Update
completed
successfully.
02h – Update failure
IO Module2 Presence
(IO Mod2 Presence)
Baseboard Temperature 5
(Platform Specific)
Baseboard Temperature 6
(Platform Specific)
IO Module2 Temperature
(I/O Mod2 Temp)
PCI Riser 3 Temperature
(PCI Riser 3 Temp)
PCI Riser 4 Temperature
(PCI Riser 4 Temp)
Baseboard Temperature 1
(Platform Specific)
Revision 1.34
13h
14h
15h
16h
17h
18h
20h
15h
08h
c = Non-fatal
[u,l] [c,nc]
nc =
Degraded
c = Non-fatal
[u,l] [c,nc]
nc =
Degraded
c = Non-fatal
[u,l] [c,nc]
nc =
Degraded
c = Non-fatal
[u,l] [c,nc]
nc =
Degraded
c = Non-fatal
[u,l] [c,nc]
nc =
Degraded
c = Non-fatal
151
Appendix B: Integrated BMC Sensor Tables
Full Sensor Name
(Sensor name in SDR)
Front Panel Temperature
(Front Panel Temp)
SSB Temperature
(SSB Temp)
Baseboard Temperature 2
(Platform Specific)
Baseboard Temperature 3
(Platform Specific)
Baseboard Temperature 4
(Platform Specific)
IO Module Temperature
(I/O Mod Temp)
PCI Riser 1 Temperature
(PCI Riser 1 Temp)
IO Riser Temperature
(IO Riser Temp)
Senso
r#
21h
22h
23h
24h
25h
26h
27h
28h
Hot-swap Backplane 1
Temperature
29h
(HSBP 1 Temp)
Hot-swap Backplane 2
Temperature
(HSBP 2 Temp)
152
2Ah
Technical Product Specification
Platform
Applicabilit
y
Sensor Type
Event/Rea
ding Type
Event Offset Triggers
Platformspecific
Temperature
Threshold
[u,l] [c,nc]
01h
01h
UNR
Temperature
Threshold
01h
01h
Platformspecific
Temperature
Threshold
01h
01h
Platformspecific
Temperature
Threshold
01h
01h
Platformspecific
Temperature
Threshold
01h
01h
Platformspecific
Temperature
Threshold
01h
01h
Platformspecific
Temperature
Threshold
01h
01h
Platformspecific
Temperature
Threshold
01h
01h
Chassisspecific
Temperature
Threshold
01h
01h
Chassisspecific
Temperature
Threshold
01h
01h
All
[u,l] [c,nc]
Contrib. To
System Status
Assert
/Deassert
Readable
Value/
Offsets
Event
Data
Rearm
Standby
nc =
Degraded
As
and
De
Analog
R, T
A
X
As
and
De
Analog
R, T
A
X
As
and
De
Analog
R, T
A
X
As
and
De
Analog
R, T
A
X
As
and
De
Analog
R, T
A
X
As
and
De
Analog
R, T
A
X
As
and
De
Analog
R, T
A
X
As
and
De
Analog
R, T
A
X
As
and
De
Analog
R, T
A
X
As
and
De
Analog
R, T
A
X
c = Non-fatal
nc =
Degraded
c = Non-fatal
[u,l] [c,nc]
nc =
Degraded
c = Non-fatal
[u,l] [c,nc]
nc =
Degraded
c = Non-fatal
[u,l] [c,nc]
nc =
Degraded
c = Non-fatal
[u,l] [c,nc]
nc =
Degraded
c = Non-fatal
[u,l] [c,nc]
nc =
Degraded
c = Non-fatal
[u,l] [c,nc]
nc =
Degraded
c = Non-fatal
[u,l] [c,nc]
nc =
Degraded
c = Non-fatal
[u,l] [c,nc]
nc =
Degraded
c = Non-fatal
Revision 1.34
Technical Product Specification
Full Sensor Name
(Sensor name in SDR)
Senso
r#
Platform
Applicabilit
y
Sensor Type
Event/Rea
ding Type
Chassisspecific
Temperature
Threshold
01h
01h
Platformspecific
Temperature
Threshold
01h
01h
2Dh
Platformspecific
Temperature
Threshold
01h
01h
2Eh
Chassis
and
Platform
Specific
Temperature
Threshold
01h
01h
Temperature
Threshold
01h
01h
Fan
Threshold
04h
01h
Fan
Generic
08h
Hot-swap Backplane 3
Temperature
2Bh
(HSBP 3 Temp)
PCI Riser 2 Temperature
(PCI Riser 2 Temp)
SAS Module Temperature
(SAS Mod Temp)
Exit Air Temperature
(Exit Air Temp)
Network Interface Controller
Temperature
Appendix B: Integrated BMC Sensor Tables
2Ch
2Fh
All
30h–
3Fh
Chassis
and
Platform
Specific
40h–
4Fh
Chassis
and
Platform
Specific
(LAN NIC Temp)
Fan Tachometer Sensors2
(Chassis specific
sensor names)
Fan Present Sensors
(Fan x Present)
Power Supply 1 Status3
(PS1 Status)
Power Supply 2 Status3
Revision 1.34
50h
51h
Chassisspecific
04h
Power Supply
08h
Power Supply
Sensor
Specific
6Fh
Event Offset Triggers
[u,l] [c,nc]
Contrib. To
System Status
Assert
/Deassert
Readable
Value/
Offsets
Event
Data
Rearm
Standby
nc =
Degraded
As
and
De
Analog
R, T
A
X
As
and
De
Analog
R, T
A
X
As
and
De
Analog
R, T
A
X
As
and
De
Analog
R, T
A
X
As
and
De
Analog
R, T
A
X
As
and
De
Analog
R, T
M
-
As
and
De
-
Triggered
Offset
Auto
-
As
and
De
–
Trig
Offset
A
X
A
X
c = Non-fatal
[u,l] [c,nc]
nc =
Degraded
c = Non-fatal
[u,l] [c,nc]
nc =
Degraded
c = Non-fatal
This sensor does not
generate any events.
[u,l] [c,nc]
nc =
Degraded
c = Non-fatal
nc =
Degraded
c = Non-fatal
[l] [c,nc]
nc =
Degraded
c = Non-fatal
01 - Device inserted
OK
00 - Presence
OK
01 - Failure
Degraded
02 – Predictive Failure
Degraded
03 - A/C lost
Degraded
06 – Configuration
error
OK
00 - Presence
OK
–
153
Appendix B: Integrated BMC Sensor Tables
Full Sensor Name
(Sensor name in SDR)
Senso
r#
Platform
Applicabilit
y
(PS2 Status)
Technical Product Specification
Sensor Type
54h
(PS1 Power In)
Power Supply 2
AC Power Input
55h
(PS2 Power In)
Power Supply 1 +12V % of
Maximum Current Output
58h
(PS1 Curr Out %)
Power Supply 2 +12V % of
Maximum Current Output
59h
(PS2 Curr Out %)
Power Supply 1 Temperature
(PS1 Temperature)
Power Supply 2 Temperature
(PS2 Temperature)
5Ch
5Dh
Hard Disk Drive 15 - 23
Status
60h
(HDD 15 - 23 Status)
68h
Processor 1 Status
(P1 Status)
154
Event Offset Triggers
Contrib. To
System Status
01 - Failure
Degraded
Sensor
Specific
02 – Predictive Failure
Degraded
03 - A/C lost
Degraded
6Fh
06 – Configuration
error
OK
08h
Chassisspecific
Power Supply 1
AC Power Input
Event/Rea
ding Type
–
70h
Chassisspecific
Other Units
Threshold
0Bh
01h
Chassisspecific
Other Units
Threshold
0Bh
01h
Chassisspecific
Current
Threshold
03h
01h
Chassisspecific
Current
Threshold
03h
01h
Chassisspecific
Temperature
Threshold
01h
01h
Chassisspecific
Temperature
Threshold
01h
01h
Chassisspecific
Drive Slot
Sensor
Specific
All
0Dh
Processor
07h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
[u] [c,nc]
nc =
Degraded
c = Non-fatal
[u] [c,nc]
nc =
Degraded
c = Non-fatal
[u] [c,nc]
nc =
Degraded
c = Non-fatal
[u] [c,nc]
nc =
Degraded
c = Non-fatal
[u] [c,nc]
nc =
Degraded
c = Non-fatal
00 - Drive Presence
OK
01- Drive Fault
Degraded
6Fh
07 - Rebuild/Remap
in progress
Degraded
Sensor
Specific
01 - Thermal trip/
FIVR
Fatal
6Fh
07 – Presence
OK
Assert
/Deassert
Readable
Value/
Offsets
As
and
De
Event
Data
Rearm
Standby
Trig
Offset
As
and
De
Analog
R, T
A
X
As
and
De
Analog
R, T
A
X
As
and
De
Analog
R, T
A
X
As
and
De
Analog
R, T
A
X
As
and
De
Analog
R, T
A
X
As
and
De
Analog
R, T
A
X
As
and
De
–
Trig
Offset
A
As
and
De
–
Trig
Offset
M
Revision 1.34
X
X
X
Technical Product Specification
Full Sensor Name
(Sensor name in SDR)
Processor 2 Status
(P2 Status)
Processor 3 Status
(P3 Status)
Processor 4 Status
(P4 Status)
Processor 1 Thermal Margin
(P1 Therm Margin)
Processor 2 Thermal Margin
(P2 Therm Margin)
Processor 3 Thermal Margin
(P3 Therm Margin)
Processor 4 Thermal Margin
(P4 Therm Margin)
Processor 1 Thermal
Control %
Appendix B: Integrated BMC Sensor Tables
Senso
r#
Platform
Applicabilit
y
71h
All
72h
73h
Platformspecific
Processor
(P4 Therm Ctrl %)
Revision 1.34
07h
07h
Event/Rea
ding Type
Event Offset Triggers
Contrib. To
System Status
Assert
/Deassert
Readable
Value/
Offsets
Sensor
Specific
01 - Thermal trip/
FIVR
Fatal
–
6Fh
07 - Presence
OK
As
and
De
Sensor
Specific
01 - Thermal trip
Fatal
07 - Presence
OK
As
and
De
01 - Thermal trip
Fatal
6Fh
Sensor
Specific
6Fh
Temperature
Threshold
01h
01h
Temperature
Threshold
01h
01h
Platformspecific
Temperature
Threshold
01h
01h
77h
Platformspecific
Temperature
Threshold
01h
01h
78h
All
Temperature
Threshold
01h
01h
Temperature
Threshold
01h
01h
Platformspecific
Temperature
Threshold
01h
01h
Platformspecific
Temperature
Threshold
01h
01h
74h
All
75h
All
76h
79h
7Ah
(P3 Therm Ctrl %)
Processor 4 Thermal
Control %
07h
Processor
All
(P2 Therm Ctrl %)
Processor 3 Thermal
Control %
Processor
Platformspecific
(P1 Therm Ctrl %)
Processor 2 Thermal
Control %
Sensor Type
7Bh
Event
Data
Rearm
Standby
Trig
Offset
M
X
–
Trig
Offset
M
X
–
Trig
Offset
M
X
07 - Presence
OK
As
and
De
-
-
-
Analog
R, T
A
–
-
-
-
Analog
R, T
A
–
-
-
-
Analog
R, T
A
–
-
-
-
Analog
R, T
A
–
[u] [c,nc]
nc =
Degraded
As
and
De
Analog
Trig
Offset
A
–
As
and
De
Analog
Trig
Offset
A
–
As
and
De
Analog
Trig
Offset
A
–
As
and
De
Analog
Trig
Offset
A
–
c = Non-fatal
[u] [c,nc]
nc =
Degraded
c = Non-fatal
[u] [c,nc]
nc =
Degraded
c = Non-fatal
[u] [c,nc]
nc =
Degraded
c = Non-fatal
155
Appendix B: Integrated BMC Sensor Tables
Full Sensor Name
(Sensor name in SDR)
Processor ERR2 Timeout
(CPU ERR2)
IERR recovery dump info
(IERR Rec Info)
Internal Error
(IERR)
MTM Level Change
(MTM Lvl Change)
Processor Population Fault
(CPU Missing)
Processor 1 DTS Thermal
Margin
Senso
r#
Platform
Applicabilit
y
7Ch
All
7Dh
80h
81h
82h
All
All
All
All
(AutoCfg Status)
156
Readable
Value/
Offsets
01 – State Asserted
Fatal
As
and
De
–
00h – Dump
successfully
OK
As
Event
Data
Rearm
Standby
Trig
Offset
A
–
_
Trig
Offset
A
_
01h – Dump failure
Processor
Digital
Discrete
01 – State Asserted
Fatal
As
and
De
–
Trig
Offset
M
–
01 – State Asserted
-
As
and
De
–
Trig
Offset
A
-
01 – State Asserted
Fatal
As
and
De
–
Trig
Offset
M
–
-
-
-
Analog
R, T
A
–
-
-
-
Analog
R, T
A
–
-
-
-
Analog
R, T
A
–
-
-
-
Analog
R, T
A
–
01 – State Asserted
-
As
and
De
–
Trig
Offset
A
-
07h
Mgmt Health
28h
Processor
07h
03h
Digital
Discrete
03h
Digital
Discrete
03h
01h
01h
Platform
Specific
Temperature
Threshold
01h
01h
86h
Platform
Specific
Temperature
Threshold
01h
01h
87h
All
Mgmt Health
Digital
Discrete
85h
Assert
/Deassert
OEM
defined
70h
Threshold
All
Contrib. To
System Status
OEM sensor
type D1h
Temperature
84h
Event Offset Triggers
03h
01h
(P4 DTS Therm Mgn)
Auto Config Status
07h
Digital
Discrete
Threshold
(P3 DTS Therm Mgn)
Processor 4 DTS Thermal
Margin
Processor
Event/Rea
ding Type
01h
All
(P2 DTS Therm Mgn)
Processor 3 DTS Thermal
Margin
Sensor Type
Temperature
83h
(P1 DTS Therm Mgn)
Processor 2 DTS Thermal
Margin
Technical Product Specification
28h
03h
Revision 1.34
Technical Product Specification
Full Sensor Name
(Sensor name in SDR)
VRD Over Temperature
(VRD Hot)
Power Supply 1 Fan Fail 13
(PS1 Fan Fail 1)
Appendix B: Integrated BMC Sensor Tables
Senso
r#
Platform
Applicabilit
y
90h
All
A0h
Chassisspecific
Sensor Type
Temperature
01h
Fan
04h
Event/Rea
ding Type
Digital
Discrete
Event Offset Triggers
Contrib. To
System Status
Assert
/Deassert
Readable
Value/
Offsets
01 - Limit exceeded
Non-fatal
As
and
De
–
Rearm
Standby
Trig
Offset
A
–
01 – State Asserted
Non-fatal
As
and
De
-
Trig
Offset
M
X
01 – State Asserted
Non-fatal
As
and
De
-
Trig
Offset
M
X
-
-
-
-
-
-
-
-
-
-
-
-
-
-
01 – State Asserted
Non-fatal
As
and
De
-
Trig
Offset
M
X
01 – State Asserted
Non-fatal
As
and
De
-
Trig
Offset
M
X
-
-
-
-
-
-
-
-
-
-
-
-
-
-
05h
Generic –
digital
discrete
03h
Power Supply 1 Fan Fail
(PS1 Fan Fail 2)
23
A1h
Chassisspecific
Fan
04h
Generic –
digital
discrete
03h
PHI 1 Status
(GPGPU1 Status)
A2h
PHI 2 Status
(GPGPU2 Status)
A3h
Power Supply 2 Fan Fail 13
(PS2 Fan Fail 1)
A4h
Platform
Specific
Status
Platform
Specific
Status
Chassisspecific
Fan
C0h
C0h
04h
OEM
Defined
70h
OEM
Defined
70h
Generic –
digital
discrete
03h
Power Supply 2 Fan Fail 23
(PS2 Fan Fail 2)
A5h
Chassisspecific
Fan
04h
Generic –
digital
discrete
03h
PHI 3 Status
(GPGPU3 Status)
A6h
PHI 4 Status
(GPGPU4 Status)
A7h
Revision 1.34
Platform
Specific
Status
Platform
Specific
Status
C0h
C0h
Event
Data
OEM
Defined
70h
OEM
Defined
70h
157
Appendix B: Integrated BMC Sensor Tables
Full Sensor Name
(Sensor name in SDR)
Senso
r#
PHI 1 Avg Pwr
Technical Product Specification
Platform
Applicabilit
y
Sensor Type
Event/Rea
ding Type
AAh
Platform
Specific
Power
Threshold
03h
01h
PHI 2 Avg Pwr
ABh
Platform
Specific
Power
Threshold
03h
01h
Processor 1 DIMM Aggregate
Thermal Margin 1
B0h
All
Temperature
Threshold
01h
01h
Temperature
Threshold
01h
01h
Temperature
Threshold
01h
01h
Temperature
Threshold
01h
01h
Platform
Specific
Temperature
Threshold
01h
01h
Platform
Specific
Temperature
Threshold
01h
01h
Platform
Specific
Temperature
Threshold
01h
01h
Platform
Specific
Temperature
Threshold
01h
01h
(P1 DIMM Thrm Mrgn1)
Processor 1 DIMM Aggregate
Thermal Margin 2
B1h
All
(P1 DIMM Thrm Mrgn2)
Processor 2 DIMM Aggregate
Thermal Margin 1
B2h
All
(P2 DIMM Thrm Mrgn1)
Processor 2 DIMM Aggregate
Thermal Margin 2
B3h
All
(P2 DIMM Thrm Mrgn2)
Processor 3 DIMM Aggregate
Thermal Margin 1
B4h
(P3 DIMM Thrm Mrgn1)
Processor 3 DIMM Aggregate
Thermal Margin 2
B5h
(P3 DIMM Thrm Mrgn2)
Processor 4 DIMM Aggregate
Thermal Margin 1
B6h
(P4 DIMM Thrm Mrgn1)
Processor 4 DIMM Aggregate
Thermal Margin 2
(P4 DIMM Thrm Mrgn2)
158
B7h
Event Offset Triggers
Contrib. To
System Status
Assert
/Deassert
Readable
Value/
Offsets
Event
Data
Rearm
Standby
-
-
-
Analog
-
-
-
-
-
-
Analog
-
-
-
[u] [c,nc]
nc =
Degraded
As
and
De
Analog
R, T
A
–
As
and
De
Analog
R, T
A
–
As
and
De
Analog
R, T
A
–
As
and
De
Analog
R, T
A
–
As
and
De
Analog
R, T
A
–
As
and
De
Analog
R, T
A
–
As
and
De
Analog
R, T
A
–
As
and
De
Analog
R, T
A
–
c = Non-fatal
[u] [c,nc]
nc =
Degraded
c = Non-fatal
[u] [c,nc]
nc =
Degraded
c = Non-fatal
[u] [c,nc]
nc =
Degraded
c = Non-fatal
[u] [c,nc]
nc =
Degraded
c = Non-fatal
[u] [c,nc]
nc =
Degraded
c = Non-fatal
[u] [c,nc]
nc =
Degraded
c = Non-fatal
[u] [c,nc]
nc =
Degraded
c = Non-fatal
Revision 1.34
Technical Product Specification
Full Sensor Name
(Sensor name in SDR)
Node Auto-Shutdown
Sensor
Senso
r#
B8h
(Auto Shutdown)
Fan Tachometer Sensors
(Chassis specific
sensor names)
Appendix B: Integrated BMC Sensor Tables
Platform
Applicabilit
y
Sensor Type
MultiNode
Specific
Power Unit
BAh–
BFh
Chassis
and
Platform
Specific
C0h
All
Processor 1 DIMM
Thermal Trip
(P1 Mem Thrm Trip)
Processor 2 DIMM
Thermal Trip
C1h
All
(P2 Mem Thrm Trip)
Processor 3 DIMM
Thermal Trip
PHI 2 Temp
(GPGPU2 Core Temp)
PHI 3 Temp
(GPGPU3 Core Temp)
PHI 4 Temp
(GPGPU4 Core Temp)
Revision 1.34
Threshold
04h
01h
Memory
Sensor
Specific
0Ch
Memory
0Ch
6Fh
Sensor
Specific
6Fh
Sensor
Specific
Memory
C4h
Platform
Specific
Temperature
Threshold
01h
01h
C5h
Platform
Specific
Temperature
Threshold
01h
01h
C6h
Platform
Specific
Temperature
Threshold
01h
01h
C7h
Platform
Specific
Temperature
Threshold
01h
01h
(P4 Mem Thrm Trip)
PHI 1 Temp
Fan
Platform
Specific
C3h
Event Offset Triggers
Contrib. To
System Status
01 – State Asserted
Non-fatal
[l] [c,nc]
nc =
Degraded
03h
Memory
Processor 4 DIMM
(GPGPU1 Core Temp)
Generic –
digital
discrete
Platform
Specific
C2h
(P3 Mem Thrm Trip)
Thermal Trip
09h
Event/Rea
ding Type
0Ch
0Ch
6Fh
Sensor
Specific
6Fh
c = Non-fatal
2
Assert
/Deassert
Readable
Value/
Offsets
As
and
De
-
As
and
De
Event
Data
Rearm
Standby
Trig
Offset
A
-
Analog
R, T
M
-
0A- Critical
overtemperature
Fatal
As
and
De
–
Trig
Offset
M
-
0A- Critical
overtemperature
Fatal
As
and
De
–
Trig
Offset
M
-
0A- Critical
overtemperature
Fatal
As
and
De
–
Trig
Offset
M
X
0A- Critical over
temperature
Fatal
As
and
De
–
Trig
Offset
M
X
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
159
Appendix B: Integrated BMC Sensor Tables
Full Sensor Name
(Sensor name in SDR)
Senso
r#
Global Aggregate
Temperature Margin 1
Platform
Applicabilit
y
Sensor Type
Event/Rea
ding Type
C8h
Platform
Specific
Temperature
Threshold
01h
01h
C9h
Platform
Specific
Temperature
Threshold
01h
01h
CAh
Platform
Specific
Temperature
Threshold
01h
01h
CBh
Platform
Specific
Temperature
Threshold
01h
01h
CCh
Platform
Specific
Temperature
Threshold
01h
01h
CDh
Platform
Specific
Temperature
Threshold
01h
01h
CEh
Platform
Specific
Temperature
Threshold
01h
01h
CFh
Platform
Specific
Temperature
Threshold
01h
01h
Voltage
02h
Voltage
02h
(Agg Therm Mrgn 1)
Global Aggregate
Temperature Margin 2
(Agg Therm Mrgn 2)
Global Aggregate
Temperature Margin 3
(Agg Therm Mrgn 3)
Global Aggregate
Temperature Margin 4
(Agg Therm Mrgn 4)
Global Aggregate
Temperature Margin 5
(Agg Therm Mrgn 5)
Global Aggregate
Temperature Margin 6
(Agg Therm Mrgn 6)
Global Aggregate
Temperature Margin 7
(Agg Therm Mrgn 7)
Global Aggregate
Temperature Margin 8
(Agg Therm Mrgn 8)
Baseboard +12V
(BB +12.0V)
Voltage Fault
(Voltage Fault)
160
Technical Product Specification
D0h
D1h
All
All
Event Offset Triggers
Contrib. To
System Status
Assert
/Deassert
Readable
Value/
Offsets
Event
Data
Rearm
Standby
-
-
-
Analog
R, T
A
–
-
-
-
Analog
R, T
A
–
-
-
-
Analog
R, T
A
–
-
-
-
Analog
R, T
A
–
-
-
-
Analog
R, T
A
–
-
-
-
Analog
R, T
A
–
-
-
-
Analog
R, T
A
–
-
-
-
Analog
R, T
A
–
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
Analog
R, T
A
–
c = Non-fatal
As
and
De
Discrete
03h
01 – Asserted
Degraded
-
-
-
A
-
Revision 1.34
Technical Product Specification
Full Sensor Name
(Sensor name in SDR)
Senso
r#
Baseboard Temperature 5
(Platform Specific)
D5h
Baseboard Temperature 6
(Platform Specific)
D6h
Baseboard CMOS Battery
(BB +3.3V Vbat)
DEh
Hot-swap Backplane 4
Temperature
E0h
(HSBP 4 Temp)
Rear Hard Disk Drive 0 -1
Status
(Rear HDD 0 - 1 Stat)
Hard Disk Drive 0 -14 Status
(HDD 0 - 14 Status)
E2h
E3h
F0h
FEh
Appendix B: Integrated BMC Sensor Tables
Platform
Applicabilit
y
Sensor Type
Event/Rea
ding Type
Platformspecific
Temperature
Threshold
01h
01h
Platformspecific
Temperature
Threshold
01h
01h
Voltage
02h
Threshold
01h
Temperature
Threshold
01h
01h
Drive Slot
Sensor
Specific
All
Chassisspecific
Chassisspecific
Chassisspecific
0Dh
6Fh
Drive Slot
0Dh
Sensor
Specific
6Fh
Event Offset Triggers
[u,l] [c,nc]
Contrib. To
System Status
Assert
/Deassert
Readable
Value/
Offsets
Event
Data
Rearm
Standby
nc =
Degraded
As
and
De
Analog
R, T
A
X
As
and
De
Analog
R, T
A
X
As
and
De
Analog
R, T
A
–
As
and
De
Analog
R, T
A
X
As
and
De
–
Trig
Offset
A
X
As
and
De
–
Trig
Offset
A
X
c = Non-fatal
[u,l] [c,nc]
nc =
Degraded
c = Non-fatal
[l] [c,nc]
nc =
Degraded
c = Non-fatal
[u,l] [c,nc]
nc =
Degraded
c = Non-fatal
00 - Drive Presence
OK
01- Drive Fault
Degraded
07 - Rebuild/Remap
in progress
Degraded
00 - Drive Presence
OK
01- Drive Fault
Degraded
07 - Rebuild/Remap
in progress
Degraded
Notes:
1.
Redundancy sensors will be only present on systems with appropriate hardware to support redundancy (for instance, fan or power supply). Note
that power supply redundancy may be lost even when both supplies are operational if the system is loaded beyond the capacity of a single power
supply.
2.
This is only applicable when the system doesn't support redundant fans. When fan redundancy is supported, then the contribution to system state
is driven by the fan redundancy sensor, not individual sensors. On a system with fan redundancy, the individual sensor severities will read the
same as the fan redundancy sensor’s severity.
Revision 1.34
161
Appendix B: Integrated BMC Sensor Tables
3.
162
Technical Product Specification
This is only applicable when the system doesn't support redundant power supplies. When redundancy is supported, then the contribution to
system state is driven by the power unit redundancy sensor. On a system with power supply redundancy, the individual sensor severities will read
the same as the power unit redundancy sensor’s severity.
Revision 1.34
Technical Product Specification
Appendix C: BIOS Sensors and SEL Data
Appendix C: BIOS Sensors and SEL Data
BIOS owns a set of IPMI-compliant Sensors. These are actually divided in ownership between
BIOS POST (GID = 01) and BIOS SMI Handler (GID = 33). The SMI Handler Sensors are typically
for logging runtime error events, but they are active during POST and may log errors such as
Correctable Memory ECC Errors if they occur.
It is important to remember that a Sensor is uniquely identified by the combination of Sensor
Owner plus Sensor Number. There are cases where the same Sensor Number is used with
different Sensor Owners – this is not a conflict. For example, in the BIOS Sensors list there is a
Sensor Number 83h for Sensor Owner 01h (BIOS POST) as well as for Sensor Owner 33h (SMI
Handler), but these are two distinct sensors reporting the same type of event from different
sources (Generator IDs 01h and 33h).
On the other hand, each distinct Sensor (GID + Sensor Number) is defined by one specific
Sensor Type describing the kind of data being reported, and one specific Event Type
describing the type of event and the format of the data being reported.
Table 78. BIOS Sensor and SEL Data
Sensor Name
Sensor
Number
Mirroring
Redundancy
State
01h
Sensor
Owner (GID)
33h (SMI
Handler)
Sensor
Type
0Ch
(Memory)
Event/Reading Type
Offset Values
0Bh (Discrete, Redundancy
State)
0h = Fully Redundant
2h = Redundancy Degraded
Event Data 2
Event Data 3
ED2 =
[7:4] = Mirroring Domain
0-1 = Channel Pair for
Socket
[3:2] = Reserved
[1:0] = Rank on DIMM
0-3 = Rank Number
ED3 =
[7:5]= Socket ID
0-3 = CPU1-4
[4:3] = Channel
0-3 = Channel A-D for
Socket
[2:0] = DIMM
0-2 = DIMM 1-3 on
Channel
Revision 1.34
163
Appendix C: BIOS Sensors and SEL Data
Sensor Name
Memory RAS
Configuration
Status
Sensor
Number
02h
Sensor
Owner (GID)
01h (BIOS
POST)
Technical Product Specification
Sensor
Type
0Ch
(Memory)
Event/Reading Type
Offset Values
09h (Digital Discrete)
0h = RAS Configuration
Disabled
1h = RAS Configuration
Enabled
Event Data 2
Event Data 3
ED2 =
[7:4] = Reserved
[3:0] Config Err
0 = None
3 = Invalid DIMM Config
for RAS Mode
ED3 =
[7:4] = Reserved
[3:0] = RAS Mode
0 = None
1 = Mirroring
2 = Lockstep
4 = Rank Sparing
Memory ECC
Error
02h
33h (SMI
Handler)
0Ch
(Memory)
6Fh (Sensor Specific Offset)
0h = Correctable Error
1h = Uncorrectable Error
ED2 =
[7:2] = Reserved
[1:0] = Rank on DIMM
0-3 = Rank Number
ED3 =
[7:5]= Socket ID
0-3 = CPU1-4
[4:3] = Channel
0-3 = Channel A-D for
Socket
[2:0] = DIMM
0-2 = DIMM 1-3 on
Channel
Legacy PCI
Error
164
03h
33h (SMI
Handler)
13h
(Critical
Interrupt)
6Fh (Sensor Specific Offset)
4h = PCI PERR
5h = PCI SERR
ED2 =
[7:0] = Bus Number
ED3 =
[7:3] = Device Number
[2:0] = Function Number
Revision 1.34
Technical Product Specification
Sensor Name
PCIe Fatal
Error
Sensor
Number
04h
Sensor
Owner (GID)
33h (SMI
Handler)
(Standard
AER Errors)
Appendix C: BIOS Sensors and SEL Data
Sensor
Type
13h
(Critical
Interrupt)
(see Sensor
14h for
continuation)
PCIe
Correctable
Error
05h
33h (SMI
Handler)
06h
01h (BIOS
POST)
Offset Values
70h (OEM Discrete)
0h = Data Link Layer
Protocol Error
1h = Surprise Link Down
Error
2h = Completer Abort
3h = Unsupported Request
4h = Poisoned TLP
5h = Flow Control Protocol
6h = Completion Timeout
7h = Receiver Buffer
Overflow
8h = ACS Violation
9h = Malformed TLP
Ah = ECRC Error
Bh = Received Fatal
Message From Downstream
Ch = Unexpected
Completion
Dh = Received
ERR_NONFATAL Message
Eh = Uncorrectable Internal
Fh = MC Blocked TLP
13h
(Critical
Interrupt)
71h (OEM Discrete)
0Fh
(System
Firmware
Progress)
6Fh (Sensor Specific Offset)
(Standard
AER Errors)
BIOS POST
Error
Event/Reading Type
0h = Receiver Error
1h = Bad DLLP
2h = Bad TLP
3h = Replay Num Rollover
4h = Replay Timer timeout
5h = Advisory Non-fatal
6h = Link BW Changed
7h = Correctable Internal
8h = Header Log Overflow
0h = System Firmware Error
(POST Error Code)
Event Data 2
Event Data 3
ED2 =
[7:0] = Bus Number
ED3 =
[7:3] = Device Number
[2:0] = Function Number
ED2 =
[7:0] = Bus Number
ED3 =
[7:3] = Device Number
[2:0] = Function Number
ED2 =
[7:0] = LSB of POST Error
Code
ED3 =
[7:0] MSB of POST Error
Code
QPI
Correctable
Errors
(reserved for
Validation)
Revision 1.34
06h
33h (SMI
Handler)
13h
(Critical
Interrupt)
72h (OEM Discrete)
Offset Reserved
ED2 =
[7:0] = Node ID
0-3 = CPU1-4
ED3 = Reserved
165
Appendix C: BIOS Sensors and SEL Data
Sensor Name
QPI Fatal
Error
Sensor
Number
07h
Sensor
Owner (GID)
33h (SMI
Handler)
(see Sensor
17h for
continuation)
QPI Link
Width
Reduced
Memory Error
Extension
(reserved for
Validation)
166
09h
10h
01h (BIOS
POST)
33h (SMI
Handler)
Technical Product Specification
Sensor
Type
13h
(Critical
Interrupt)
13h
(Critical
Interrupt)
0Ch
(Memory)
Event/Reading Type
Offset Values
73h (OEM Discrete)
0h = Link Layer
Uncorrectable ECC Error
1h = Protocol Layer
Poisoned Packet Reception
Error
2h = Link/PHY Init Failure
with resultant degradation
in link width
3h = PHY Layer detected
drift buffer alarm
4h = PHY detected latency
buffer rollover
5h = PHY Init Failure
6h = Link Layer generic
control error (buffer
overflow/underflow, credit
underflow etc.)
7h = Parity error in link or
PHY layer
8h = Protocol layer timeout
detected
9h = Protocol layer failed
response
Ah = Protocol layer illegal
packet field, target Node ID
Error, etc.
Bh = Protocol Layer
Queue/table
overflow/underflow
Ch = Viral Error
Dh = Protocol Layer parity
error
Eh = Routing Table Error
Fh = (unused)
77h (OEM Discrete)
1h = Reduced to ½ width
2h = Reduced to ¼ width
Event Data 2
Event Data 3
ED2 =
[7:0] = Node ID
0-3 = CPU1-4
ED3 = No Data
ED2 =
[7:0] = Node ID
0-3 = CPU1-4
ED3 = No Data
7Fh (OEM Discrete)
ED2 = Reserved
Offset Reserved
ED3 = Reserved
Revision 1.34
Technical Product Specification
Sensor Name
Sparing
Redundancy
State
Sensor
Number
11h
Sensor
Owner (GID)
33h (SMI
Handler)
Appendix C: BIOS Sensors and SEL Data
Sensor
Type
0Ch
(Memory)
Event/Reading Type
Offset Values
0Bh (Discrete, Redundancy
State)
0h = Fully Redundant
2h = Redundancy Degraded
Event Data 2
Event Data 3
ED2 =
[7:4] = Sparing Domain
0-3 = Channel A-D for
Socket
[3:2] = Reserved
[1:0] = Rank on DIMM
0-3 = Rank Number
ED3 =
[7:5]= Socket ID
0-3 = CPU1-4
[4:3] = Channel
0-3 = Channel A-D for
Socket
[2:0] = DIMM
0-2 = DIMM 1-3 on
Channel
Memory RAS
Mode Select
12h
01h (BIOS
POST)
0Ch
(Memory)
09h (Digital Discrete)
0h = RAS Configuration
Disabled
1h = RAS Configuration
Enabled
ED2 = Prior Mode
[7:4] = Reserved
[3:0] = RAS Mode
0 = None
1 = Mirroring
2 = Lockstep
4 = Rank Sparing
ED3 = Selected Mode
[7:4] = Reserved
[3:0] = RAS Mode
0 = None
1 = Mirroring
2 = Lockstep
4 = Rank Sparing
Revision 1.34
167
Appendix C: BIOS Sensors and SEL Data
Sensor Name
Memory
Parity Error
Sensor
Number
13h
Sensor
Owner (GID)
33h (SMI
Handler)
Technical Product Specification
Sensor
Type
0Ch
(Memory)
Event/Reading Type
Event Data 2
Offset Values
6Fh (Sensor Specific Offset)
Event Data 3
ED2 = Validity
[7:5] = Reserved
[4] = Channel Validity
Check
0 = ED3 Chan # Not Valid
1 = ED3 Chan # Is Valid
[3] = DIMM Validity Check
0 = ED3 DIMM # Not
Valid
1 = ED3 DIMM # Is Valid
[2:0] = Error Type
0 = Not Known
3 = Command and
Address Parity Error
3h = Command and Address
Parity Error
ED3 = Location
[7:5]= Socket ID
0-3 = CPU1-4
[4:2] = Channel
0-3 = Channel A-D for
Socket
[1:0] = DIMM
0-2 = DIMM 1-3 on
Channel
PCIe Fatal
Error#2
14h
33h (SMI
Handler)
13h
(Critical
Interrupt)
76h (OEM Discrete)
33h (SMI
Handler)
0Fh
(System
Firmware
Progress)
70h (OEM Discrete)
ED2 = Reserved
1h = BIOS Recovery Start
ED3 = Reserved
33h (SMI
Handler)
0Fh
(System
Firmware
Progress)
F0h (OEM Discrete)
ED2 = Reserved
1h = BIOS Recovery
Complete
ED3 = Reserved
(Standard
AER Errors)
(continuation
of Sensor
04h)
BIOS
Recovery
Start
15h
BIOS
Recovery
Completion
15h
168
0h = Atomic Egress Blocked
1h = TLP Prefix Blocked
Fh = Unspecified Non-AER
Fatal Error
ED2 =
[7:0] = Bus Number
ED3 =
[7:3] = Device Number
[2:0] = Function Number
Revision 1.34
Technical Product Specification
Sensor Name
QPI Fatal
Error
(continuation
of Sensor
07h)
Sensor
Number
17h
Sensor
Owner (GID)
33h (SMI
Handler)
Appendix C: BIOS Sensors and SEL Data
Sensor
Type
13h
(Critical
Interrupt)
Event/Reading Type
Offset Values
74h (OEM Discrete)
0h = Illegal inbound request
1h = IIO Write Cache
Uncorrectable Data ECC
Error
2h = IIO CSR crossing 32-bit
boundary Error
3h = IIO Received XPF
physical/logical redirect
interrupt inbound
Event Data 2
Event Data 3
ED2 =
[7:0] = Node ID
0-3 = CPU1-4
ED3 = No Data
4h = IIO Illegal SAD or
Illegal or non-existent
address or memory
5h = IIO Write Cache
Coherency Violation
Revision 1.34
169
Appendix D: POST Code Diagnostic LED Decoder
Technical Product Specification
Appendix D: POST Code Diagnostic LED Decoder
During the system POST process, Diagnostic LED Codes are used extensively as a mechanism
to indicate progress and Fatal Halt conditions independently of the video display. If the
system hangs or halts, the Diagnostic LED display can help determine the reason even when
video is not available.
These Diagnostic LEDs are equivalent to the Legacy “Port 80 POST Codes”, and a Legacy I/O
Port 80 output will be displayed as a Diagnostic LED code.
The Diagnostic LEDs are a set of LEDs found on the back edge of the server board. There are 8
Diagnostic LEDs which form a 2 hex digit (8 bit) code read left-to-right as facing the rear of the
server.
Figure 49. Diagnostic LED Placement Diagram
An LED which is ON represents a 1 bit value, and an LED which is OFF represents a 0 bit value.
The LED bit values are read as Most Significant Bit to the left, Least Significant Bit to the right.
170
Revision 1.34
Technical Product Specification
Appendix D: POST Code Diagnostic LED Decoder
In the following example, the BIOS sends a value of ACh to the diagnostic LED decoder. The
LEDs are decoded as follows:
Table 79. POST Code LED Example
Upper Nibble AMBER LEDs
LEDs
Status
Results

MSB
LED #7
8h
ON
1
LED #6
4h
OFF
0
LED #5
2h
ON
1
Lower Nibble GREEN LEDs
LED #4
1h
OFF
0
LED #3
8h
ON
1
LED #2
4h
ON
1
LED #1
2h
OFF
0
LSB
LED #0
1h
OFF
0
Ah
Ch
Upper nibble bits = 1010b = Ah; Lower nibble bits = 1100b = Ch; the two are concatenated as ACh.
POST Memory Initialization MRC Diagnostic Codes
This is a brief list of the Diagnostic LED codes displayed during memory initialization by the
Memory Reference Code (MRC), the BIOS component responsible for it. There are two types of
POST Diagnostic Codes used by the MRC, Fatal Error Codes and Progress Codes.
MRC Fatal Error Codes are necessary because if the Memory Initialization fails badly for some
reason – like no usable memory installed – the system would not have the resources to give
any other error indication. So in the case of a major failure during Memory Initialization, the
system outputs a Fatal Error Code to Port 80 (the Diagnostic LEDs) and executes a Halt. These
Fatal Error Halts do not change the Status LED, and they do not get logged as SEL Events.
The MRC Progress Codes are displays to the Diagnostic LEDs that show the execution point in
the MRC operational path at each step. The intent is that if the system hangs during execution
of the MRC, the LED display will tell at what point in the code the system was executing.
Be aware that these are Diagnostic LED display codes used in early POST by the MRC. Later in
POST these same Diagnostic LED display codes are used for other BIOS Progress Codes.
Also, be aware that the MRC Fatal Error Codes and MRC Progress Codes are not controlled by
the BIOS and are subject to change at the discretion of the Memory Reference Code teams.
Table 80. MRC Fatal Error Codes
Error Code
Fatal Error Code Explanation (with MRC Internal Minor Code)
0xE8
No Usable Memory Error:
01h = No memory was detected via SPD read, or invalid config that causes no operable
memory.
02h = Memory DIMMs on all channels of all sockets are disabled due to hardware memtest
error.
03h = No memory installed. All channels are disabled.
0xE9
Memory is locked by Intel® Trusted Execution Technology and is inaccessible.
Revision 1.34
171
Appendix D: POST Code Diagnostic LED Decoder
Error Code
Technical Product Specification
Fatal Error Code Explanation (with MRC Internal Minor Code)
0xEA
DDR4 Channel Training Error:
01h = Error on read DQ/DQS (Data/Data Strobe) init
02h = Error on Receive Enable
03h = Error on Write Leveling
04h = Error on write DQ/DQS (Data/Data Strobe)
0xEB
Memory Test Failure:
01h = Software memtest failure.
02h = Hardware memtest failed.
03h = Hardware Memtest failure in Lockstep Channel mode requiring a channel to be
disabled. This is a fatal error which requires a reset and calling MRC with a different RAS mode
to retry.
0xED
DIMM Configuration/Population Error:
01h = Different DIMM types ( RDIMM, LRDIMM) are detected installed in the system.
02h = Violation of DIMM population rules.
03h = The third DIMM slot cannot be populated when QR DIMMs are installed.
04h = UDIMMs are not supported.
05h = Unsupported DIMM Voltage.
0xEF
Indicates a CLTT table structure error.
Table 81. MRC Progress Codes
Progress Code
Main Sequence
Subsequences/Subfunctions
0xB0
Detect DIMM population
—n/a—
0xB1
Set DDR4 frequency
—n/a—
0xB2
Gather remaining SPD data
—n/a—
0xB3
Program registers on the memory controller
level
—n/a—
0xB4
Evaluate RAS modes and save rank information
—n/a—
0xB5
Program registers on the channel level
—n/a—
0xB6
Perform the JEDEC defined initialization
sequence
—n/a—
0xB7
Train DDR4 ranks
—n/a—
0xB8
172
0x01

Read DQ/DQS training
0x02

Receive Enable training
0x03

Write Leveling training
0x04

Write DQ/DQS training
0x05

DDR channel training done
Initialize CLTT
—n/a—
Revision 1.34
Technical Product Specification
Progress Code
Appendix D: POST Code Diagnostic LED Decoder
Main Sequence
Subsequences/Subfunctions
0xB9
Hardware memory test and init
—n/a—
0xBA
Execute software memory init
—n/a—
0xBB
Program memory map and interleaving
—n/a—
0xBC
Program RAS configuration
—n/a—
0xBF
MRC is done
—n/a—
POST Progress Code Checkpoints
During the system boot process, the BIOS executes a number of platform configuration
processes, each of which is assigned a specific POST Progress Code, a 2-digit hexadecimal
number. As each configuration routine is started, the BIOS displays the POST Progress Code
on the Diagnostic LEDs found on the back edge of the server board.
To assist in troubleshooting a system hang during the POST process, the POST Progress Code
displayed in the Diagnostic LEDs can be used to identify the last POST process to begin
execution.
Table 82. POST Progress Codes
Progress Code
Description
SEC Phase
0x01
First POST code after CPU reset
0x02
Microcode load begin
0x03
CRAM initialization begin
0x04
Pei Cache When Disabled
0x05
SEC Core At Power On Begin.
0x06
Early CPU initialization during Sec
Phase.
QPI RC (Fully leverage without platform change)
Revision 1.34
0xA1
Collect info such as SBSP, Boot Mode,
Reset type etc
0xA3
Setup minimum path between SBSP &
other sockets
0xA7
Topology discovery and route
calculation
0xA8
Program final route
0xA9
Program final IO SAD setting
173
Appendix D: POST Code Diagnostic LED Decoder
Progress Code
Technical Product Specification
Description
0xAA
Protocol layer and other uncore
settings
0xAB
Transition links to full speed operation
0xAC
Phy layer setting
0xAD
Link layer settings
0xAE
Coherency settings
0xAF
QPI initialization done
0x07
Early SB initialization during Sec Phase.
0x08
Early NB initialization during Sec
Phase.
0x09
End Of Sec Phase.
0x0E
Microcode Not Found.
0x0F
Microcode Not Loaded.
PEI Phase
0x10
PEI Core
0x11
CPU PEIM
0x15
NB PEIM
0x19
SB PEIM
MRC Progress Codes
At this point the MRC Progress Code sequence is executed
See Table 77.
0x31
Memory Installed
0x32
CPU PEIM (CPU Init)
0x33
CPU PEIM (Cache Init)
0x4F
Dxe IPL started
DXE Phase
174
0x60
DXE Core started
0x61
DXE NVRAM Init
0x62
DXE Setup Init
0x63
DXE CPU Init
0x65
DXE CPU BSP Select
0x66
DXE CPU AP Init
Revision 1.34
Technical Product Specification
Appendix D: POST Code Diagnostic LED Decoder
Progress Code
Revision 1.34
Description
0x68
DXE PCI Host Bridge Init
0x69
DXE NB Init
0x6A
DXE NB SMM Init
0x70
DXE SB Init
0x71
DXE SB SMM Init
0x72
DXE SB devices Init
0x78
DXE ACPI Init
0x79
DXE CSM Init
0x80
DXE BDS Started
0x81
DXE BDS connect drivers
0x82
DXE PCI Bus begin
0x83
DXE PCI Bus HPC Init
0x84
DXE PCI Bus enumeration
0x85
DXE PCI Bus resource requested
0x86
DXE PCI Bus assign resource
0x87
DXE CON_OUT connect
0x88
DXE CON_IN connect
0x89
DXE SIO Init
0x8A
DXE USB start
0x8B
DXE USB reset
0x8C
DXE USB detect
0x8D
DXE USB enable
0x91
DXE IDE begin
0x92
DXE IDE reset
0x93
DXE IDE detect
0x94
DXE IDE enable
0x95
DXE SCSI begin
0x96
DXE SCSI reset
0x97
DXE SCSI detect
0x98
DXE SCSI enable
0x99
DXE verifying SETUP password
175
Appendix D: POST Code Diagnostic LED Decoder
Progress Code
Technical Product Specification
Description
0x9B
DXE SETUP start
0x9C
DXE SETUP input wait
0x9D
DXE Ready to Boot
0x9E
DXE Legacy Boot
0x9F
DXE Exit Boot Services
0xC0
RT Set Virtual Address Map Begin
0xC2
DXE Legacy Option ROM init
0xC3
DXE Reset system
0xC4
DXE USB Hot plug
0xC5
DXE PCI BUS Hot plug
0xC6
DXE NVRAM cleanup
0xC7
DXE ACPI Enable
0x00
Clear POST Code
S3 Resume
0x40
S3 Resume PEIM (S3 started)
0x41
S3 Resume PEIM (S3 boot script)
0x42
S3 Resume PEIM (S3 Video Repost)
0x43
S3 Resume PEIM (S3 OS wake)
BIOS Recovery
176
0x46
PEIM which detected forced Recovery
condition
0x47
PEIM which detected User Recovery
condition
0x48
Recovery PEIM (Recovery started)
0x49
Recovery PEIM (Capsule found)
0x4A
Recovery PEIM (Capsule loaded)
Revision 1.34
Technical Product Specification
Appendix E: POST Code Errors
Appendix E: POST Code Errors
The table below lists the supported POST Error Codes, with a descriptive Error Message text
for each. There is also a Response listed, which classifies the error as Minor, Major, or Fatal
depending on how serious the error is and what action the system should take.
The Response section in the following table indicates one of these actions:

Minor: The message is displayed on the screen or on the Error Manager screen, and an
error is logged to the SEL. The system continues booting in a degraded state. The user
may want to replace the erroneous unit. The POST Error Pause option setting in the
BIOS setup does not have any effect on this error.

Major: The message is displayed on the Error Manager screen, and an error is logged
to the SEL. The POST Error Pause option setting in the BIOS setup determines
whether the system pauses to the Error Manager for this type of error so the user can
take immediate corrective action or the system continues booting.
Note that for 0048 “Password check failed”, the system halts, and then after the next
reset/reboot will display the error code on the Error Manager screen.

Fatal: The system halts during post at a blank screen with the text “Unrecoverable
fatal error found. System will not boot until the error is resolved” and “Press <F2>
to enter setup.” The POST Error Pause option setting in the BIOS setup does not have
any effect on this class of error.
When the operator presses the F2 key on the keyboard, the error message is displayed
on the Error Manager screen, and an error is logged to the SEL with the error code. The
system cannot boot unless the error is resolved. The user needs to replace the faulty
part and restart the system.
Table 83. POST Error Codes and Messages
Error Code
0012
Error Message
System RTC date/time not set
Response
Major
0048
Password check failed
Major
0140
PCI component encountered a PERR error
Major
0141
PCI resource conflict
Major
0146
PCI out of resources error
Major
0191
Processor core/thread count mismatch detected
Fatal
0192
0194
Processor cache size mismatch detected
Processor family mismatch detected
Fatal
Fatal
0195
Processor Intel(R) QPI link frequencies unable to synchronize
Fatal
0196
Processor model mismatch detected
Fatal
0197
Processor frequencies unable to synchronize
Fatal
5220
BIOS Settings reset to default settings
Major
5221
Passwords cleared by jumper
Major
5224
Password clear jumper is Set
Major
Revision 1.34
177
Appendix E: POST Code Errors
Technical Product Specification
Error Code
8130
Processor 01 disabled
Response
Major
8131
Processor 02 disabled
Major
8160
Processor 01 unable to apply microcode update
Major
8161
Processor 02 unable to apply microcode update
Major
8170
Processor 01 failed Self Test (BIST)
Major
8171
Processor 02 failed Self Test (BIST)
Major
8180
Processor 01 microcode update not found
Minor
8181
Processor 02 microcode update not found
Minor
8190
Watchdog timer failed on last boot
Major
8198
OS boot watchdog timer failure
Major
8300
Baseboard management controller failed self test
Major
8305
Hot Swap Controller failure
Major
83A0
Management Engine (ME) failed self test
Major
83A1
Management Engine (ME) Failed to respond.
Major
84F2
Baseboard management controller failed to respond
Major
84F3
Baseboard management controller in update mode
Major
84F4
Sensor data record empty
Major
84FF
System event log full
Minor
8500
Memory component could not be configured in the selected RAS mode
Major
8501
DIMM Population Error
Major
8520
DIMM_A1 failed test/initialization
Major
8523
DIMM_B1 failed test/initialization
Major
8526
DIMM_C1 failed test/initialization
Major
8529
DIMM_D1 failed test/initialization
Major
852C
DIMM_E1 failed test/initialization
Major
852F
DIMM_F1 failed test/initialization
Major
8532
DIMM_G1 failed test/initialization
Major
8535
DIMM_H1 failed test/initialization
Major
8540
DIMM_A1 disabled
Major
8543
DIMM_B1 disabled
Major
8546
DIMM_C1 disabled
Major
8549
DIMM_D1 disabled
Major
854C
DIMM_E1 disabled
Major
854F
DIMM_F1 disabled
Major
8552
DIMM_G1 disabled
Major
8555
DIMM_H1 disabled
Major
8560
DIMM_A1 encountered a Serial Presence Detection (SPD) failure
Major
8563
DIMM_B1 encountered a Serial Presence Detection (SPD) failure
Major
8566
DIMM_C1 encountered a Serial Presence Detection (SPD) failure
Major
8569
DIMM_D1 encountered a Serial Presence Detection (SPD) failure
Major
856C
DIMM_E1 encountered a Serial Presence Detection (SPD) failure
Major
178
Error Message
Revision 1.34
Technical Product Specification
Appendix E: POST Code Errors
Error Code
856F
Error Message
DIMM_F1 encountered a Serial Presence Detection (SPD) failure
Response
Major
8572
DIMM_G1 encountered a Serial Presence Detection (SPD) failure
Major
8575
DIMM_H1 encountered a Serial Presence Detection (SPD) failure
Major
8604
POST Reclaim of non-critical NVRAM variables
Minor
8605
BIOS Settings are corrupted
Major
8606
NVRAM variable space was corrupted and has been reinitialized
Major
Recovery boot has been initiated.
Fatal
8607
Note: The Primary BIOS image may be corrupted or the system may hang during
POST. A BIOS update is required.
92A3
Serial port component was not detected
Major
92A9
Serial port component encountered a resource conflict error
Major
A000
TPM device not detected.
Minor
A001
TPM device missing or not responding.
Minor
A002
TPM device failure.
Minor
A003
TPM device failed self test.
Minor
A100
BIOS ACM Error
Major
A421
PCI component encountered a SERR error
Fatal
A5A0
PCI Express component encountered a PERR error
Minor
A5A1
PCI Express component encountered an SERR error
Fatal
A6A0
DXE Boot Services driver: Not enough memory available to shadow a Legacy
Option ROM.
Minor
POST Error Beep Codes
The following table lists POST Error Beep Codes. Prior to system video initialization, the BIOS
uses these beep codes to inform users of error conditions. The beep code is followed by a
user visible code displayed on the Diagnostic LEDs.
Table 84. POST Error Beep Codes
Beeps
Error Message
USB device action
POST Progress Code
N/A
Description
Short beep sounded whenever USB device is
discovered in POST, or inserted or removed during
runtime.
1 long
Intel® TXT security
violation
0xAE, 0xAF
System halted because Intel® Trusted Execution
Technology detected a potential violation of system
security.
3
Memory error
Multiple
System halted because a fatal error related to the
memory was detected.
3 long
and 1
CPU mismatch
error
0xE5, 0xE6
System halted because a fatal error related to the
CPU family/core/cache mismatch was detected.
1
The following Beep Codes are sounded during BIOS Recovery.
2
Recovery started
Revision 1.34
N/A
Recovery boot has been initiated.
179
Appendix E: POST Code Errors
Beeps
4
Error Message
Recovery failed
POST Progress Code
N/A
Technical Product Specification
Description
Recovery has failed. This typically happens so quickly
after recovery is initiated that it sounds like a 2-4
beep code.
The following Beep Codes are from the BMC.
1-5-2-1
CPU socket
population error
N/A
CPU1 socket is empty, or sockets are populated
incorrectly – CPU1 must be populated before CPU2.
1-5-2-4
MSID Mismatch
N/A
MSID mismatch occurs if a processor is installed into
a system board that has incompatible power
capabilities.
1-5-4-2
Power fault
N/A
DC power unexpectedly lost (power good dropout) –
Power unit sensors report power unit failure offset.
1-5-4-4
Power control
fault
N/A
Power good assertion timeout – Power unit sensors
report soft power control failure offset.
1-5-1-2
VR Watchdog
Timer
N/A
VR controller DC power on sequence not completed
in time.
1-5-1-4
Power Supply
Status
N/A
The system does not power on or unexpectedly
powers off and a Power Supply Unit (PSU) is present
that is an incompatible model with one or more other
PSUs in the system.
180
Revision 1.34
Technical Product Specification
Appendix F: Statement of Volatility
Appendix F: Statement of Volatility
This Appendix describes the volatile and non-volatile components on the Intel® Server Board
S2600KP Product Family. It is not the intention of this document to include any components
not directly on the listed Intel® Server Boards, such as the chassis components, processors,
memory, hard drives, or add-in cards.
Server Board Components
Intel® servers contain several components that can be used to store data. A list of components
for the Intel® Server Board S2600KPR is included in the table below. The sections below the
table provide additional information about the fields in this table.
Component Type
Size
Board Location
U4B1
User Data
No
(firmware)
Non-Volatile
16 MB
Non-Volatile
Name
Firmware Flash
16 MB
U4D3
No (BIOS)
BIOS Flash
Non-Volatile
4 MB
U5N1
No
Connect-IB Flash
Non-Volatile
32 KB
U4A2
No
NIC EEPROM
Volatile
125 MB
U4B2
No
firmware SDRAM
Component Type
Three types of components are on an Intel® Server Board. These types are:

Non-volatile: Non-volatile memory is persistent, and is not cleared when power is
removed from the system. Non-Volatile memory must be erased to clear data. The
exact method of clearing these areas varies by the specific component. Some areas are
required for normal operation of the server, and clearing these areas may render the
server board inoperable.

Volatile: Volatile memory is cleared automatically when power is removed from the
system.

Battery powered RAM: Battery powered RAM is similar to volatile memory, but is
powered by a battery on the server board. Data in Battery powered Ram is persistent
until the battery is removed from the server board.
Size
The size of each component includes sizes in bits, Kbits, bytes, kilobytes (KB) or megabytes
(MB).
Revision 1.34
181
Appendix F: Statement of Volatility
Technical Product Specification
Board Location
The physical location of each component is specified in the Board Location column. The board
location information corresponds to information on the server board silkscreen.
User Data
The flash components on the server boards do not store user data from the operating system.
No operating system level data is retained in any listed components after AC power is
removed. The persistence of information written to each component is determined by its type
as described in the table.
Each component stores data specific to its function. Some components may contain
passwords that provide access to that device’s configuration or functionality. These passwords
are specific to the device and are unique and unrelated to operating system passwords. The
specific components that may contain password data are:

BIOS: The server board BIOS provides the capability to prevent unauthorized users
from configuring BIOS settings when a BIOS password is set. This password is stored in
BIOS flash, and is only used to set BIOS configuration access restrictions.

BMC: The server boards support an Intelligent Platform Management Interface (IPMI)
2.0 conformant baseboard management controller (BMC). The BMC provides health
monitoring, alerting and remote power control capabilities for the Intel® Server Board.
The BMC does not have access to operating system level data.
The BMC supports the capability for remote software to connect over the network and
perform health monitoring and power control. This access can be configured to require
authentication by a password. If configured, the BMC will maintain user passwords to
control this access. These passwords are stored in the BMC flash.
182
Revision 1.34
Technical Product Specification
Glossary
Glossary
This glossary contains important terms used in the preceding chapters. For ease of use,
numeric entries are listed first (for example, 82460GX) with alpha entries following (for
example, AGP 4x). Acronyms are then entered in their respective place, with non-acronyms
following.
Table 85. Glossary
Term
ACPI
Definition
Advanced Configuration and Power Interface
AP
Application Processor
ARP
Address Resolution Protocal
BIOS
Basic Input/Output System
BIST
Built-In Self Test
BMC
Baseboard Management Controller
Bridge
Circuitry connecting one computer bus to another, allowing an agent on one to access the other
BSP
Bootstrap Processor
Byte
8-bit quantity.
CATERR
On a catastrophic hardware event the core signals CATERR to the uncore. The core enters a
halted state that can only be exited by a reset.
CMOS
In terms of this specification, this describes the PC-AT compatible region of battery-backed 128
bytes of memory, which normally resides on the server board.
DCMI
Data Center Management Interface
DHCP
Dynamic Host Configuration Protocal
DIMM
Dual In-line Memory Module
EEPROM
Electrically Erasable Programmable Read-Only Memory
EPS
External Product Specification
FRB
Fault Resilient Booting
FRU
Field Replaceable Unit
GB
1024 MB
GPIO
General Purpose I/O
HSC
Hot-Swap Controller
Hz
Hertz (1 cycle/second)
I2C
Inter-Integrated Circuit Bus
IA
Intel® Architecture
ILM
Independent Loading Mechanism
IMC
Integrated Memory Controller
IP
Internet Protocol
IPMB
Intelligent Platform Management Bus
IPMI
Intelligent Platform Management Interface
KB
1024 bytes
LAN
Local Area Network
Revision 1.34
183
Glossary
Technical Product Specification
Term
Definition
LED
Light Emitting Diode
LSB
Least Significant Bit
LUN
Logical Unit Number
MAC
Media Access Control
MB
1024KB
ME
Management Engine
ms
Milliseconds
MSB
Most Significant Bit
NIC
Network Interface Controller
NMI
Nonmaskable Interrupt
NTB
Non-Transparent Bridge
OEM
Original Equipment Manufacturer
PECI
Platform Environment Control Interface
PEF
Platform Event Filtering
POST
Power-On Self Test
PWM
Pulse-Width Modulation
QPI
QuickPath Interconnect
QSFP+
Quad Small Form-factor Pluggable Plus
RAM
Random Access Memory
ROM
Read Only Memory
RTC
Real-Time Clock (Component of ICH peripheral chip on the server board)
RMM4
Remote Management Module 4
SDR
Sensor Data Record
SEEPROM
Serial Electrically Erasable Programmable Read-Only Memory
SEL
System Event Log
SIO
Server Input/Output
SMBus*
System Management BUS
SMI
Server Management Interrupt (SMI is the highest priority nonmaskable interrupt)
SMM
Server Management Mode
SMS
Server Management Software
SNMP
Simple Network Management Protocol
TDP
Thermal Design Power
TIM
Thermal Interface Material
UART
Universal Asynchronous Receiver/Transmitter
VLSI
Very Large Scale Integration
VRD
Voltage Regulator Down
VT
Virtualization Technology
184
Revision 1.34
Technical Product Specification
Reference Documents
Reference Documents

Intel® Server Board S2600KP Product Family Specification Update

Intel® Server Board S2600KP Product Family and Intel® Compute Module HNS2600KP
Product Family Service Guide

Intel® Server System BIOS External Product Specification for Intel® Server Systems
supporting the Intel® Xeon® processor E5-2600 v3/v4 product family

Intel® Server System BMC Firmware External Product Specification for Intel® Server
Systems supporting the Intel® Xeon® processor E5-2600 V3/V4 product family

Intel® Remote Management Module 4 Technical Product Specification

Intel® Remote Management Module 4 and Integrated BMC Web Console Users Guide

Intel® Xeon® Processor E5-4600/2600/2400/1600 v3/v4 Product Families External
Design Specification

Intel® Chipset C610 product family External Design Specification

Intel® Ethernet Controller I350 Family Product Brief

SmaRT & CLST Architecture on Intel Systems and Power Supplies Specification

Advanced Configuration and Power Interface Specification, Revision 3.0,
http://www.acpi.info/.

Intelligent Platform Management Bus Communications Protocol Specification, Version
1.0. 1998. Intel Corporation, Hewlett-Packard Company, NEC Corporation, Dell
Computer Corporation.

Intelligent Platform Management Interface Specification, Version 2.0. 2004. Intel
Corporation, Hewlett-Packard Company, NEC Corporation, Dell Computer Corporation.

Platform Support for Serial-over-LAN (SOL), TMode, and Terminal Mode External
Architecture Specification, Version 1.1, 02/01/02, Intel Corporation.

Alert Standard Format (ASF) Specification, Version 2.0, 23 April 2003, ©2000-2003,
Distributed Management Task Force, Inc., http://www.dmtf.org.
Revision 1.34
185
Download PDF