(10–20 kVA/kW)
Parallelable up to 400 kVA/kW
PowerWAVE 8000DPA
Modular UPS designed
for low and medium
power applications.
PowerWAVE 8000DPA
Capacities from 10 kVA/kW to
200 kVA/kW in 10 kVA/kW or 20 kVA/kW
modular steps
Parallelable frames up to 400 kVA/kW
Available as tower (ST) or
19” rack-mountable (RI) solutions
Fully rated output power (blade friendly);
20 kVA = 20kW
N+1 redundancy up to 180 kVA/kW N+1
in a single frame
‘Six nines’ (99.9999%) availability
Key benefits
Individual static switches per module
Each module has its own display and
controller
Each module has its own control logic
Separate or common battery
configuration
Ideal for low to medium,
high-density critical power
protection applications.
Three-phase UPS built for low to
medium, high-density power protection
applications. Leading-edge modular
design using proven decentralised
parallel architecture (DPA) technology.
The PowerWAVE 8000DPA offers
incredible energy efficiency, 99.9999%
availability and flexible scalability in
either a tower or rack-mountable
solution.
Up to 95.5% efficiency across a wide
load range
Near unity input power factor at partial
and full loads (PF=0.99 @ 100% load)
Low input harmonic distortion
(THDi<3%)
The right solution
PowerWAVE 8000DPA is
available in two versions
Advanced Decentralised Parallel
Architecture (DPA)
Easy to replace ‘hot-swap’
modules
Distributed control and power
PowerWAVE 8000DPA ST (tower)
is available for high-density applications
requiring a standard power protection
solution including frame, UPS, battery
and communication. This solution
delivers power protection from
10–200 kVA/KW (180 kVA/KW N+1) in
10 kVA/KW or 20 kVA/KW modular steps
to provide a maximum power density of
472 kW/m2. PowerWAVE 8000DPA
cabinet can be paralleled horizontally to
increase the capacity up to 400 kVA/kW.
Independent hot-swap modules
Replace or add modules with
no downtime
The PowerWAVE 8000DPA RI (19” rackmountable) solution includes UPS,
battery and communication, which can
be integrated into any 19” rack
(independent of manufacturer) and
provides up to 80 kVA/KW (60 kVA/KW
N+1) making it ideal for integrated IT,
telecom or other applications.
PowerWAVE 8000DPA ST (tower)
Up to 10 UPS modules
Slot for optional
SNMP card
Customer inputs and
volt-free outputs /
RS232 serial interface
Maintenance bypass
switch
Parallel interface
AC input terminals
AC output terminals
Battery terminal rail
Earth bar
No single points of failure
Cost effective scalability & ‘right sizing’
Simple power upgrade
Decentralised Parallel Architecture (DPA)
means each UPS module contains all
the hardware and software required
for full-system operation. They share no
common components so a DPA parallel
system offers extremely high availability.
In addition, potential single points of
failure are eliminated and system uptime
is maximised. PowerWAVE 8000DPA
UPS modules can be paralleled to
provide redundancy (parallel
redundancy) or to increase the system’s
total capacity.
Future proof investment
True ‘hot-swap’ modularity enables the
safe removal and/or insertion of UPS
modules into a PowerWAVE 8000DPA
system without risk to the critical load
and without the need to either transfer
the critical load onto raw mains or
remove power from the critical load. This
directly addresses today’s requirement
for continuous uptime, reducing mean
time to repair (MTTR).
High reliability
Blade friendly
Generator friendly
Reliability maximised
Supports blade servers
Generator compatible
Automatic parallel redundant operation
Supports leading power factors
Soft start – introduces the generator
load in steps
Parallel redundant (N+1) UPS systems
provide the highest level of reliability by
ensuring that the number of UPS
modules in a system is a minimum of
one (N) over and above the number
required (N) to fully support the critical
load.
Blade servers typically have a leading
power factor, which can present
problems to UPS systems, particularly if
they are not designed to power such
loads. The PowerWAVE 8000DPA is
designed to power all types of electrical
loads, including blade servers. It can
provide fully rated output power to
power factors in the range of 0.9 leading
to 0.8 lagging.
The PowerWAVE 8000DPA is designed
to automatically operate as a parallel
redundant system, ensuring that the
critical load always receives the highest
level of power protection.
PowerWAVE 8000DPA RI (19” rack-mountable)
UPS modules
Internal battery storage
RS232 serial interface
Customer inputs and
volt-free outputs
Maintenance bypass switch
Slot for optional SNMP card
Battery fuses
The PowerWAVE 8000DPA offers a
highly effective solution when
introducing a generator to the critical
load. If the load exceeds 50 per cent of
the generator’s standby rating, switching
the load in a single step presents a
number of dangers. To negate this, each
of the ‘hot-swap’ modules within the
PowerWAVE 8000DPA’s modular frame
come equipped with ‘soft start’
capability. This allows the modules to be
switched on sequentially, introducing the
generator to the load in more
manageable steps.
Class-leading energy efficiency
– low total cost of ownership
Very high operating efficiency
Additionally, PowerWAVE 8000DPA has
a near unity input power factor at full
load (and even partial loads) reducing
the size of the input cable and fuses,
thereby saving on materials and costs.
Reduced installation and upgrade costs
Near unity input power factor and low
input (THDi) – reduces running costs
The PowerWAVE 8000DPA delivers
class-leading efficiency of up to 95.5%
across a wide load range significantly
reducing system running costs and site
air conditioning costs.
Input current total harmonic distortion
(THDi) of less than 3% virtually
eliminates harmonic distortion of the
mains supply. This saves unnecessary
oversizing of gen-sets, cabling and
circuit breakers; avoids extra heating of
input transformers; and extends the
overall lifetime of all input components.
All these benefits ensure that the
PowerWAVE 8000DPA offers one of the
lowest ‘total cost of ownerships’ and
smallest carbon footprints of any UPS
system in its class.
Input power factor versus load (Leading)
1
0.96
0.985
25%
50%
0.99
0.99
75%
100%
Input power factor
0.8
PowerWAVE 8000DPA has a near unity input
power factor at full load (and even partial loads)
reducing the size of the input cable and fuses,
thereby saving on materials and costs.
0.6
0.4
0.2
0
Load (%)
Input current distortion THDi
Input current total harmonic distortion (THDi) of
<3% virtually eliminates harmonic distortion of
the mains supply.
6.0
5.5
Input THDi %
5.0
4.5
4.0
4.0
3.7
3.4
3.5
3.0
3.0
2.5
2.0
1.5
25%
50%
Load (%)
75%
100%
Reduced TCO – AC–AC efficiency
97
95.5
95.5
96
95
Efficiency (%)
95
94.5
94
The PowerWAVE 8000DPA’s 95.5% true online
efficiency significantly reduces system running
costs and site air-conditioning costs. This helps
reduce the organisation’s carbon footprint.
*Depending on configuration.
93
92
91
90
25%
50%
Load (%)
75%
100%
Blade server friendly power
25
Power (kW versus KVA)
-0.80
1.00
0.80
20
Designed to power all types of electrical loads
including blade servers, the PowerWAVE
8000DPA can provide fully rated output power
from 0.9 leading to 0.8 lagging.
Additional kW
*Depending on battery configuration.
15
10
Constant kW
5
0
-0.75 -0.80 -0.85 -0.90 -0.95 1.00 0.95 0.90 0.85 0.80 0.75 0.70 0.65
kW
PowerWAVE 8000DPA ST
ST tower range – 10-200 kVA/kW
ST 40 – 2 modules
ST 80 – 4 modules
ST 60 – 3 modules
ST 120 – 6 modules
ST 200 – 10 modules
Dimensions WxHxD:
550 x 1135 x 775 mm
Dimensions WxHxD:
550 x 1135 x 775 mm
Dimensions WxHxD:
550 x 1975 x 775 mm
Dimensions WxHxD:
550 x1 975 x 775 mm
Dimensions WxHxD:
550 x 1975 x 775 mm
No. of internal batteries:
2 x 40 x 7.2/9Ah
Total 80 blocks
External battery ONLY
No. of internal batteries:
3 x (2x40) x 7.2/9Ah
Total 240 blocks
External battery ONLY
External battery ONLY
PowerWAVE 8000DPA RI
19” rack-mountable range – 10-80 kVA/kW
With batteries
RI 11 – 1 module
RI 12 – 1 module
RI 22 – 2 modules
RI24 – 2 modules
Dimensions WxHxD:
488 x 487 x 735 mm (11 HU)
Dimensions WxHxD:
488 x 665 x 735 mm (15 HU)
Dimensions WxHxD:
488 x 798 x 735 mm (18 HU)
Dimensions WxHxD:
488 x1153 x 735 mm (26 HU)
Number of batteries: 40
Number of batteries: 80
Number of batteries: 80
Number of batteries: 160
Without batteries
RI 10 – 1 module
RI 20 – 2 modules
RI 40 – 4 modules
Dimensions WxHxD:
488 x 310 x 565 mm (7 HU)
Dimensions WxHxD:
488 x 440 x 565 mm (10 HU)
Dimensions WxHxD:
488 x 798 x 735 mm (18 HU)
UK product catalogue V2 Sept 17
Uninterruptible Power
Supplies Ltd,
Woodgate,
Bartley Wood Business Park,
Hook, Hampshire RG27 9XA
Tel: 01256 386700
ISO 9001
UKAS
ACCREDITED
Fax: 01256 386701
Email: sales@upspower.co.uk
Download PDF