HP ProCurve Switch 3500 Series


Add to my manuals
30 Pages

advertisement

HP ProCurve Switch 3500 Series | Manualzz
QuickSpecs
HP ProCurve Switch 3500 Series
Overview
HP ProCurve Switch 3500yl-24G-PWR Intelligent Edge
HP ProCurve Switch 3500yl-48G-PWR Intelligent Edge
Models
HP ProCurve Switch 3500yl-24G-PWR Intelligent Edge
HP ProCurve Switch 3500yl-48G-PWR Intelligent Edge
HP ProCurve 3500-24 Switch
HP ProCurve 3500-24-PoE Switch
HP ProCurve 3500-48 Switch
HP ProCurve 3500-48-PoE Switch
J8692A
J8693A
J9470A
J9471A
J9472A
J9473A
Key features
Advanced access layer & Small Distribution
Enterprise-class performance and security
Intelligent Edge feature set with L2-L4
Scalable 10/100/1000 & 10/100 PoE connectivity
Unified core-to-edge ProVision software
Introduction
The HP ProCurve Switch 3500 Series consists of the most advanced intelligent edge switches in the HP ProCurve Networking product
line. The 3500 series includes 24-port and 48-port stackables. The foundation for all these switches is a purpose-built,
programmable ProVision ASIC that allows the most demanding networking features, such as Quality of Service (QoS) and security,
to be implemented in a scalable yet granular fashion. With a variety of Gigabit and 10/100 interfaces, integrated PoE and Non-PoE
options,10-GbE capability on Gigabit switches, the 3500 switches offer excellent investment protection, flexibility, and scalability, as
well as ease of deployment, operation, and maintenance.
Features and Benefits
Industry-leading warranty*
Management
Remote Intelligent Mirroring:
Mirroring mirrors selected ingress/egress traffic based on ACL, port, MAC address, or VLAN to a local or
remote 8200zl/6600/6200yl/5400zl/3500 switch anywhere on the network
RMON, XRMON, and sFlow v5:
v5 provide advanced monitoring and reporting capabilities for statistics, history, alarms, and
events
IEEE 802.1AB Link Layer Discovery Protocol (LLDP): automated device discovery protocol for easy mapping by network
management applications
Uni-Directional Link Detection (UDLD): monitors cable between two switches and shuts down the ports on both ends if the
cable is broken turning the bi-directional link into uni-directional; this prevents network problems such as loops
Management simplicity:
simplicity ProCurve-common networking features and CLI implementation (common across ProCurve
8200zl/6600/6200yl/5400zl/3500 switches)
DA - 13282
Worldwide — Version 3 — August 12, 2009
Page 1
QuickSpecs
HP ProCurve Switch 3500 Series
Overview
Command authorization:
authorization leverages RADIUS to link a custom list of CLI commands to individual network administrator's login;
also provides an audit trail
Friendly port names:
names allow assignment of descriptive names to ports
Dual flash images:
images provides independent primary and secondary OS files for backup while upgrading
Multiple configuration files:
files multiple configuration files can be stored to the flash image
Connectivity
NEW IPv6:
IPv6
IPv6 host: the switches can be managed and deployed at the edge of IPv6 networks
Dual stack (IPv4/IPv6): provides transition mechanism from IPv4 to IPv6; supports connectivity for both protocols
MLD snooping: forwards IPv6 multicast traffic to the appropriate interface; prevents IPv6 multicast
traffic from flooding the network
IPv6 ACL/QoS: supports ACL and QoS for IPv6 network traffic
IPv6 ready: the switch hardware can support IPv6 routing, tunneling, and security; these features will be available when
enabled via software update in follow-on releases
IEEE 802.3af Power over Ethernet:
Ethernet provides up to 15.4 W per port to IEEE 802.3af-compliant PoE powered devices such as
IP phones, wireless access points, and security cameras
Pre-standard PoE support:
support detects and provides power to pre-standard PoE devices; see list of supported devices in the
product FAQ at www.procurve.com
Jumbo frames:
frames on Gigabit and 10-Gigabit ports, allow high-performance remote backup and disaster-recovery services
Auto-MDIX:
Auto-MDIX automatically adjusts for straight-through or crossover cables on all 10/100 and 10/100/1000 ports
Performance
High-speed/capacity architecture:
architecture up to 153.6 Gbps crossbar switching fabric provides intra- and inter- module switching
with up to 111.5 million pps throughput on the purpose-built ProVision ASICs
Selectable queue configurations:
configurations increase performance by selecting the number of queues and associated memory buffering
that best meet the requirements of your network applications
Resiliency and high availability
Virtual Router Redundancy Protocol (requires Premium License): VRRP allows groups of two routers to dynamically back each
other up to create highly available routed environments
IEEE 802.1s Multiple Spanning Tree Protocol:
Protocol provides high link availability in multiple VLAN environments by allowing
multiple spanning trees; encompasses IEEE 802.1D Spanning Tree Protocol and IEEE 802.1w Rapid Spanning Tree Protocol
NEW Server-to-switch distributed trunking:
trunking allows a server to connect to two switches with one logical trunk that consists of
multiple physical connections; enables load-balancing and increases resiliency
IEEE 802.3ad Link Aggregation Control Protocol (LACP) and ProCurve trunking:
trunking support up to 60 trunks, each with up to 8
links (ports) per trunk
Layer 2 switching
IEEE 802.1ad Q-in-Q (requires Premium License): increases the scalability of Ethernet network by providing a hierarchical
structure; connects multiple LANs on high-speed campus or metro network
ProCurve switch meshing:
meshing dynamically load-balances across multiple active redundant links to increase available aggregate
bandwidth
VLAN support and tagging:
tagging supports the IEEE 802.1Q standard and 2,048 VLANs simultaneously
IEEE 802.1v protocol VLANs:
VLANs isolate select non-IPv4 protocols automatically into their own VLANs
GARP VLAN Registration Protocol:
Protocol allows automatic learning and dynamic assignment of VLANs
Layer 3 services
DA - 13282
Worldwide — Version 3 — August 12, 2009
Page 2
QuickSpecs
HP ProCurve Switch 3500 Series
Overview
UDP helper function:
function UDP broadcasts can be directed across router interfaces to specific IP unicast or subnet broadcast
addresses and prevent server spoofing for UDP services such as DHCP
Loopback interface address:
address defines an address in RIP and OSPF that can always be reachable, improving diagnostic
capability
Layer 3 routing
Static IP routing:
routing provides manually configured routing; includes ECMP capability
RIP:
RIP provides RIPv1 and RIPv2 routing
OSPF (requires Premium License): includes host-based ECMP to provide link redundancy/scalable bandwidth and NSSA
Security
Access control lists (ACLs): provide filtering based on the IP field, source/destination IP address/subnet, and
source/destination TCP/UDP port number on a per-VLAN or per-port basis
Multiple user authentication methods:
methods
IEEE 802.1X users per port:
port provides authentication of multiple IEEE 802.1X users per port; prevents user
“piggybacking” on another user's IEEE 802.1X authentication
Web-based authentication:
authentication authenticates from Web browser for clients that do not support IEEE 802.1X supplicant;
customized remediation can be processed on an external Web server
MAC-based authentication:
authentication client is authenticated with the RADIUS server based on client's MAC address
Concurrent IEEE 802.1X, Web, and MAC authentication schemes per port:
port switch port will accept up to 32 sessions
of IEEE 802.1X, Web, and MAC authentications
Virus throttling:
throttling detects traffic patterns typical of WORM-type viruses and either throttles or entirely prevents the ability of the
virus to spread across the routed VLANs or bridged interfaces, without requiring external appliances
DHCP protection:
protection blocks DHCP packets from unauthorized DHCP servers, preventing denial-of-service attacks
Secure management access:
access all access methods--CLI, GUI, or MIB--are securely encrypted through SSHv2, SSL, and/or
SNMPv3
USB Secure Autorun (requires HP ProCurve Manager Plus): deploys, diagnoses, and updates switch using USB flash drive;
works with secure credential to prevent tampering
Switch CPU protection:
protection provides automatic protection against malicious network traffic trying to shut down the switch
ICMP throttling:
throttling defeats ICMP denial-of-service attacks by enabling any switch port to automatically throttle ICMP traffic
Identity-driven ACL:
ACL enables implementation of a highly granular and flexible access security policy and VLAN assignment
specific to each authenticated network user
STP BPDU port protection:
protection blocks Bridge Protocol Data Units (BPDUs) on ports that do not require BPDUs, preventing forged
BPDU attacks
Dynamic IP lockdown:
lockdown works with DHCP protection to block traffic from unauthorized hosts, preventing IP source address
spoofing
Dynamic ARP protection:
protection blocks ARP broadcasts from unauthorized hosts, preventing eavesdropping or theft of network data
STP Root Guard:
Guard protects root bridge from malicious attack or configuration mistakes
Detection of malicious attacks:
attacks monitors ten types of network traffic and sends a warning when an anomaly that potentially
can be caused by malicious attacks is detected
Port security:
security allows access only to specified MAC addresses, which can be learned or specified by the administrator
MAC address lockout:
lockout prevents configured particular MAC addresses from connecting to the network
Source-port filtering:
filtering allows only specified ports to communicate with each other
RADIUS/TACACS+: eases switch management security administration by using a password authentication server
Secure Shell (SSHv2): encrypts all transmitted data for secure, remote command-line interface (CLI) access over IP networks
Secure Sockets Layer (SSL): encrypts all HTTP traffic, allowing secure access to the browser-based management GUI in the
switch
Secure FTP:
FTP allows secure file transfer to/from the switch; protects against unwanted file downloads or unauthorized copying
of switch configuration file
NEW Management Interface Wizard:
Wizard CLI-based step-by-step configuration tool to help ensure that management interfaces
DA - 13282
Worldwide — Version 3 — August 12, 2009
Page 3
QuickSpecs
HP ProCurve Switch 3500 Series
Overview
such as SNMP, telnet, SSH, SSL, Web, and USB are secured to desired level
Switch management logon security:
security can require either RADIUS or TACACS+ authentication for secure switch CLI logon
Security banner:
banner displays a customized security policy when users log in to the switch
Convergence
IP multicast routing (requires Premium License): includes PIM Sparse and Dense modes to route IP multicast traffic
IP multicast snooping (data-driven IGMP): automatically prevents flooding of IP multicast traffic
LLDP-MED (Media Endpoint Discovery): a standard extension of LLDP that stores values for parameters such as QoS and
VLAN to automatically configure network devices such as IP phones
RADIUS VLAN for voice:
voice uses standard RADIUS attribute and LLDP-MED to automatically configure VLAN for IP phones
PoE allocations:
allocations supports multiple methods (automatic, IEEE 802.3af class, LLDP-MED, or user specified) to allocate PoE
power for more efficient energy savings
Quality of Service (QoS)
NEW Advanced classifier-based QoS:
QoS classifies traffic using multiple match criteria based on L2/3/4 information; applies
QoS policies such as setting priority level and rate limit to selected traffic per port or per VLAN
Layer 4 prioritization:
prioritization enables prioritization based on TCP/UDP port numbers
Traffic prioritization:
prioritization allows real-time traffic classification into eight priority levels mapped to eight queues
Bandwidth shaping:
shaping
Port-based rate limiting:
limiting per-port ingress/egress enforced maximum bandwidth
Classifier-based rate limiting:
limiting use ACL to enforce maximum bandwidth for ingress traffic on each port
Guaranteed minimum:
minimum per-port, per-queue egress-based guaranteed minimum bandwidth
Class of Service (CoS): sets the IEEE 802.1p priority tag based on IP address, IP Type of Service (ToS), L3 protocol, TCP/UDP
port number, source port, and DiffServ
Warranty and support*
support
ProCurve Lifetime Warranty:
Warranty for as long as you own the product, with next-business-day advance replacement (available in
most countries).
Electronic and telephone support:
support limited electronic and telephone support is available from HP. Refer to the HP Web site at:
www.procurve.com/support for details on the support provided and the period during which support is available.
Software releases:
releases refer to the HP Web site at: www.procurve.com/support for details on the software releases provided and
the period during which software releases are available.
* For as long as you own the product, with next-business-day advance replacement (available in most countries). The following
hardware products and their related series modules have a one-year hardware warranty with extensions available: HP ProCurve
Routing Switch 9300m Series, HP ProCurve Switch 8100fl Series, HP ProCurve Network Access Controller 800, and HP ProCurve
DCM Controller. The following hardware mobility products have a one-year hardware warranty with extensions available: HP
ProCurve M111 Client Bridge, HP ProCurve MSM3xx-R Access Points, HP ProCurve MSM7xx Mobility and Access Controllers, HP
ProCurve RF Manager IDS/IPS Systems, HP ProCurve MSM Power Supplies, HP ProCurve 1-Port Power Injector, and HP ProCurve
CNMS Appliances. Disk drives in the HP ProCurve ONE Services zl Modules have a five year hardware warranty. Standalone
software, upgrades, or licenses may have a different warranty duration. For details, refer to the ProCurve Software License, Warranty,
and Support booklet at: www.procurve.com/warranty.
DA - 13282
Worldwide — Version 3 — August 12, 2009
Page 4
QuickSpecs
HP ProCurve Switch 3500 Series
Technical Specifications
HP ProCurve Switch
Ports
3500yl-24G-PWR
Intelligent Edge (J8692A)
1 open module slot
20 auto-sensing 10/100/1000 ports (IEEE 802.3 Type 10Base-T, IEEE
802.3u Type 100Base-TX, IEEE 802.3ab Type 1000Base-T); Media Type:
Auto-MDIX; Duplex: 10Base-T/100Base-TX: half or full; 1000Base-T: full
only
1 RS-232C DB-9 console port
4 dual-personality ports; each port can be used as either an RJ-45
10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type
100Base-TX; IEEE 802.3ab 1000Base-T Gigabit Ethernet) with PoE or an
open mini-GBIC slot (for use with mini-GBIC transceivers)
Supports a maximum of 4 10-GbE ports
Maximum ports
Physical characteristics
Memory and processor
Mounting
Performance
Environment
Electrical characteristics
DA - 13282
Dimensions
15.43(d) x 17.44(w) x 1.73(h) in. (39.2 x 44.3 x
4.4 cm) (1U height)
Weight
14.11 lb. (6.4 kg)
10G module
ARM9 @ 200 MHz; packet buffer size: 36 Mb
QDR SDRAM
Management Module
Stackable memory and processor: Freescale
PowerPC 8540 @ 666 MHz, 4 MB flash, 128
MB compact flash, 256 MB DDR SDRAM
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware
included); horizontal surface mounting only
1000 Mb: < 3.7 µs (FIFO 64-byte packets);
Latency
10 Gbps: < 2.1 µs (FIFO 64-byte packets)
up to 75.7 million pps
Throughput
101.8 Gbps
Routing/Switching
capacity
105.6 Gbps
Switch fabric speed
10,000 entries
Routing table size
MAC address table size 64,000 entries
32ºF to 131ºF (0ºC to 55ºC); 32°F to 104°F
Operating temperature
(40°C) when used with any X2 10-GbE
15% to 95% @ 104ºF (40ºC), non-condensing
Operating relative
humidity
-40ºF to 158ºF (-40ºC to 70ºC)
Non-operating/
Storage temperature
15% to 90% @ 149ºF (65ºC), non-condensing
Non-operating/
Storage relative humidity
up to 15,000 ft. (4.6 km)
Altitude
Power: 52.7 dB, Pressure: 44.8 dB ISO 7779,
Acoustic
ISO 9296
The switch automatically adjusts to any voltage
Description
between 100-127 and 200-240 volts and either
50 or 60 Hz
Maximum heat dissipation 865 BTU/hr (912.9 kJ/hr)
100-127 / 200-240 VAC
Voltage
Worldwide — Version 3 — August 12, 2009
Page 5
QuickSpecs
HP ProCurve Switch 3500 Series
Technical Specifications
Current
Idle power
Maximum power rating
PoE power
Frequency
Notes
Safety
Emissions
Immunity
Management
Notes
Services
Standards and protocols
DA - 13282
10.0 / 5.0 A
98 W
623 W
398 W
50 / 60 Hz
Idle power is the actual power consumption of
the device with no ports connected.
Maximum power rating and maximum heat
dissipation are the worst-case theoretical
maximum numbers provided for planning the
infrastructure with fully loaded PoE (if equipped),
100% traffic, all ports plugged in, and all
modules populated. PoE Power is the power
supplied by the internal power supply, it is
dependent on the type and quantity of power
supplies and may be supplemented with the use
of a External Power Supply (EPS).
CSA 22.2 No. 60950; UL 60950; IEC 60950; EN 60950
FCC Class A; VCCI Class A; EN 55022/CISPR 22 Class A
EN
EN 55024, CISPR 24
ESD
IEC 61000-4-2; 4 kV CD, 8 kV AD
IEC 61000-4-3; 3 V/m
Radiated
IEC 61000-4-4; 1.0 kV (power line), 0.5 kV
EFT/Burst
(signal line)
IEC 61000-4-5; 1 kV/2 kV AC
Surge
IEC 61000-4-6; 3 V
Conducted
IEC 61000-4-8; 1 A/m, 50 or 60 Hz
Power frequency
magnetic field
IEC 61000-4-11; >95% reduction, 0.5 period;
Voltage dips and
interruptions
30% reduction, 25 periods
EN 61000-3-2, IEC 61000-3-2
Harmonics
EN 61000-3-3, IEC 61000-3-3
Flicker
HP ProCurve Manager Plus; HP ProCurve Manager (included); commandline interface; Web browser; configuration menu; out-of-band management
(serial RS-232C)
When using mini-GBICs with this product, mini-GBICs with revision "B" or
later (product number ends with the letter "B" or later, e.g., J4858B, J4859C)
are required.
Refer to the HP Web site at: www.procurve.com/services for details on the
service-level descriptions and product numbers. For details about services
and response times in your area, please contact your local HP sales office.
RFC 1591 DNS (client)
Device Management
HTML and telnet management
IEEE 802.1ad Q-in-Q (Premium License)
General Protocols
IEEE 802.1D MAC Bridges
IEEE 802.1p Priority
Worldwide — Version 3 — August 12, 2009
Page 6
QuickSpecs
HP ProCurve Switch 3500 Series
Technical Specifications
IP Multicast
IPv6
DA - 13282
IEEE 802.1Q VLANs
IEEE 802.1s Multiple Spanning Trees
IEEE 802.1v VLAN classification by Protocol and
Port
IEEE 802.1w Rapid Reconfiguration of Spanning
Tree
IEEE 802.3ad Link Aggregation Control Protocol
(LACP)
IEEE 802.3af Power over Ethernet
IEEE 802.3x Flow Control
RFC 768 UDP
RFC 783 TFTP Protocol (revision 2)
RFC 792 ICMP
RFC 793 TCP
UDLD (Uni-directional Link Detection)
RFC 826 ARP
RFC 854 TELNET
RFC 868 Time Protocol
RFC 951 BOOTP
RFC 1058 RIPv1
RFC 1350 TFTP Protocol (revision 2)
RFC 1519 CIDR
RFC 1542 BOOTP Extensions
RFC 2030 Simple Network Time
Protocol (SNTP) v4
RFC 2131 DHCP
RFC 2453 RIPv2
RFC 2548 (MS-RAS-Vendor only)
RFC 3046 DHCP Relay Agent Information
Option
RFC 3576 Ext to RADIUS (CoA only)
RFC 3768 VRRP (Premium License)
RFC 4675 RADIUS VLAN & Priority
RFC 3376 IGMPv3 (host joins only)
RFC 3973 Draft 2 PIM Dense Mode (Premium
License)
RFC 4601 Draft 10 PIM Sparse Mode (Premium
License)
RFC 1981 IPv6 Path MTU Discovery
RFC 2460 IPv6 Specification
RFC 2710 Multicast Listener Discovery (MLD) for
IPv6
RFC 2925 Remote Operations MIB (Ping only)
RFC 3019 MLDv1 MIB
RFC 3315 DHCPv6 (client only)
RFC 3513 IPv6 Addressing Architecture
RFC 3596 DNS Extension for IPv6
RFC 3810 MLDv2 (host joins only)
RFC 4022 MIB for TCP
RFC 4113 MIB for UDP
RFC 4251 SSHv6 Architecture
Worldwide — Version 3 — August 12, 2009
Page 7
QuickSpecs
HP ProCurve Switch 3500 Series
Technical Specifications
MIBs
Network Management
OSPF
QoS/Cos
Security
HP ProCurve Switch
Ports
RFC 4252 SSHv6 Authentication
RFC 4253 SSHv6 Transport Layer
RFC 4254 SSHv6 Connection
RFC 4293 MIB for IP
RFC 4419 Key Exchange for SSH
RFC 4443 ICMPv6
RFC 4541 IGMP & MLD Snooping Switch
RFC 4861 IPv6 Neighbor Discovery
RFC 4862 IPv6 Stateless Address Autoconfiguration
RFC 1213 MIB II
RFC 1493 Bridge MIB
RFC 1724 RIPv2 MIB
RFC 1850 OSPFv2 MIB
RFC 2021 RMONv2 MIB
RFC 2096 IP Forwarding Table MIB
RFC 2613 SMON MIB
RFC 2618 RADIUS Client MIB
RFC 2620 RADIUS Accounting MIB
RFC 2665 Ethernet-Like-MIB
RFC 2668 802.3 MAU MIB
RFC 2674 802.1p and IEEE 802.1Q Bridge MIB
RFC 2737 Entity MIB (Version 2)
RFC 2787 VRRP MIB
RFC 2863 The Interfaces Group MIB
RFC 2925 Ping MIB
IEEE 802.1AB Link Layer Discovery Protocol
(LLDP)
RFC 2819 Four groups of RMON: 1 (statistics),
2 (history), 3 (alarm) and 9 (events)
RFC 3176 sFlow
ANSI/TIA-1057 LLDP Media Endpoint Discovery
(LLDP-MED)
SNMPv1/v2c/v3
XRMON
RFC 2328 OSPFv2 (Premium License)
RFC 3101 OSPF NSSA
RFC 2474 DiffServ Precedence, including 8
queues/port
RFC 2597 DiffServ Assured Forwarding (AF)
RFC 2598 DiffServ Expedited Forwarding (EF)
IEEE 802.1X Port Based Network Access Control
RFC 1492 TACACS+
RFC 2865 RADIUS (client only)
RFC 2866 RADIUS Accounting
Secure Sockets Layer (SSL)
SSHv1/SSHv2 Secure Shell
1 open module slot
DA - 13282
Worldwide — Version 3 — August 12, 2009
Page 8
QuickSpecs
HP ProCurve Switch 3500 Series
Technical Specifications
3500yl-48G-PWR
Intelligent Edge (J8693A)
Physical characteristics
Memory and processor
Mounting
Performance
Environment
Electrical characteristics
(Achieved Miercom
Certified Green Award)
DA - 13282
44 auto-sensing 10/100/1000 ports (IEEE 802.3 Type 10Base-T, IEEE
802.3u Type 100Base-TX, IEEE 802.3ab Type 1000Base-T); Media Type:
Auto-MDIX; Duplex: 10Base-T/100Base-TX: half or full; 1000Base-T: full
only
1 RS-232C DB-9 console port
4 dual-personality ports; each port can be used as either an RJ-45
10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type
100Base-TX; IEEE 802.3ab 1000Base-T Gigabit Ethernet) with PoE or an
open mini-GBIC slot (for use with mini-GBIC transceivers)
Supports a maximum of 4 10-GbE ports
Maximum ports
16.93(d) x 17.44(w) x 1.73(h) in. (43.0 x 44.3 x
Dimensions
4.4 cm) (1U height)
16.09 lb. (7.3 kg)
Weight
ARM9 @ 200 MHz; packet buffer size: 36 Mb
10G module
QDR SDRAM
Stackable memory and processor: Freescale
Management Module
PowerPC 8540 @ 666 MHz, 4 MB flash Mb,
128 MB compact flash, 256 MB DDR SDRAM
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware
included); horizontal surface mounting only
1000 Mb: < 3.7 µs (FIFO 64-byte packets);
Latency
10 Gbps: < 2.1 µs (FIFO 64-byte packets)
up to 111.5 million pps
Throughput
149.8 Gbps
Routing/Switching
capacity
153.6 Gbps
Switch fabric speed
10,000 entries
Routing table size
MAC address table size 64,000 entries
32ºF to 131ºF (0ºC to 55ºC); 32°F to 104°F
Operating temperature
(40°C) when used with any X2 10-GbE
15% to 95% @ 104ºF (40ºC), non-condensing
Operating relative
humidity
-40ºF to 158ºF (-40ºC to 70ºC)
Non-operating/
Storage temperature
15% to 95% @ 149ºF (65ºC), non-condensing
Non-operating/
Storage relative humidity
up to 15,000 ft. (4.6 km)
Altitude
Power: 55.1 dB, Pressure: 45.3 dB ISO 7779,
Acoustic
ISO 9296
The switch automatically adjusts to any voltage
Description
between 100-127 and 200-240 volts and either
50 or 60 Hz
Maximum heat dissipation 1144 BTU/hr (1206.9 kJ/hr)
100-127 / 200-240 VAC
Voltage
10.0 / 5.0 A
Current
142 W
Idle power
Worldwide — Version 3 — August 12, 2009
Page 9
QuickSpecs
HP ProCurve Switch 3500 Series
Technical Specifications
Maximum power rating
PoE power
Frequency
Notes
Safety
Emissions
Immunity
Management
Notes
Services
Standards and protocols
DA - 13282
705 W
398 W
50 / 60 Hz
Maximum power rating and maximum heat
dissipation are the worst-case theoretical
maximum numbers provided for planning the
infrastructure with fully loaded PoE (if equipped),
100% traffic, all ports plugged in, and all
modules populated.
Maximum power draw if not using any PoE
power is 200 W (1.8 A @ 110 V, 0.9 A @ 220
V). Full load switch only heat spec listed above
subtracts heat dissapated in external PoE
powered devices. Heat dissipation does not
include heat dissipated by the PoE powered
devices themselves.
CSA 22.2 No. 60950; UL 60950; IEC 60950; EN 60950
FCC Class A; VCCI Class A; EN 55022/CISPR 22 Class A
EN
EN 55024, CISPR 24
ESD
IEC 61000-4-2; 4 kV CD, 8 kV AD
IEC 61000-4-3; 3 V/m
Radiated
IEC 61000-4-4; 1.0 kV (power line), 0.5 kV
EFT/Burst
(signal line)
IEC 61000-4-5; 1 kV/2 kV AC
Surge
IEC 61000-4-6; 3 V
Conducted
IEC 61000-4-8; 1 A/m, 50 or 60 Hz
Power frequency
magnetic field
IEC 61000-4-11; >95% reduction, 0.5 period;
Voltage dips and
interruptions
30% reduction, 25 periods
EN 61000-3-2, IEC 61000-3-2
Harmonics
EN 61000-3-3, IEC 61000-3-3
Flicker
HP ProCurve Manager Plus; HP ProCurve Manager (included); commandline interface; Web browser; configuration menu; out-of-band management
(serial RS-232C)
When using mini-GBICs with this product, mini-GBICs with revision "B" or
later (product number ends with the letter "B" or later, e.g., J4858B, J4859C)
are required.
Refer to the HP Web site at: www.procurve.com/services for details on the
service-level descriptions and product numbers. For details about services
and response times in your area, please contact your local HP sales office.
RFC 1591 DNS (client)
Device Management
HTML and telnet management
IEEE 802.1ad Q-in-Q (Premium License)
General Protocols
IEEE 802.1D MAC Bridges
IEEE 802.1p Priority
IEEE 802.1Q VLANs
Worldwide — Version 3 — August 12, 2009
Page 10
QuickSpecs
HP ProCurve Switch 3500 Series
Technical Specifications
IP Multicast
IPv6
DA - 13282
IEEE 802.1s Multiple Spanning Trees
IEEE 802.1v VLAN classification by Protocol and
Port
IEEE 802.1w Rapid Reconfiguration of Spanning
Tree
IEEE 802.3ad Link Aggregation Control Protocol
(LACP)
IEEE 802.3af Power over Ethernet
IEEE 802.3x Flow Control
RFC 768 UDP
RFC 783 TFTP Protocol (revision 2)
RFC 792 ICMP
RFC 793 TCP
UDLD (Uni-directional Link Detection)
RFC 826 ARP
RFC 854 TELNET
RFC 868 Time Protocol
RFC 951 BOOTP
RFC 1058 RIPv1
RFC 1350 TFTP Protocol (revision 2)
RFC 1519 CIDR
RFC 1542 BOOTP Extensions
RFC 2030 Simple Network Time Protocol (SNTP)
v4
RFC 2131 DHCP
RFC 2453 RIPv2
RFC 2548 (MS-RAS-Vendor only)
RFC 3046 DHCP Relay Agent Information
Option
RFC 3576 Ext to RADIUS (CoA only)
RFC 3768 VRRP (Premium License)
RFC 4675 RADIUS VLAN & Priority
RFC 3376 IGMPv3 (host joins only)
RFC 3973 Draft 2 PIM Dense Mode (Premium
License)
RFC 4601 Draft 10 PIM Sparse Mode (Premium
License)
RFC 1981 IPv6 Path MTU Discovery
RFC 2460 IPv6 Specification
RFC 2710 Multicast Listener Discovery (MLD) for
IPv6
RFC 2925 Remote Operations MIB (Ping only)
RFC 3019 MLDv1 MIB
RFC 3315 DHCPv6 (client only)
RFC 3513 IPv6 Addressing Architecture
RFC 3596 DNS Extension for IPv6
RFC 3810 MLDv2 (host joins only)
RFC 4022 MIB for TCP
RFC 4113 MIB for UDP
RFC 4251 SSHv6 Architecture
RFC 4252 SSHv6 Authentication
Worldwide — Version 3 — August 12, 2009
Page 11
QuickSpecs
HP ProCurve Switch 3500 Series
Technical Specifications
MIBs
Network Management
OSPF
QoS/Cos
Security
HP ProCurve 3500-24
Switch (J9470A)
Ports
RFC 4253 SSHv6 Transport Layer
RFC 4254 SSHv6 Connection
RFC 4293 MIB for IP
RFC 4419 Key Exchange for SSH
RFC 4443 ICMPv6
RFC 4541 IGMP & MLD Snooping Switch
RFC 4861 IPv6 Neighbor Discovery
RFC 4862 IPv6 Stateless Address Autoconfiguration
RFC 1213 MIB II
RFC 1493 Bridge MIB
RFC 1724 RIPv2 MIB
RFC 1850 OSPFv2 MIB
RFC 2021 RMONv2 MIB
RFC 2096 IP Forwarding Table MIB
RFC 2613 SMON MIB
RFC 2618 RADIUS Client MIB
RFC 2620 RADIUS Accounting MIB
RFC 2665 Ethernet-Like-MIB
RFC 2668 802.3 MAU MIB
RFC 2674 802.1p and IEEE 802.1Q Bridge MIB
RFC 2737 Entity MIB (Version 2)
RFC 2787 VRRP MIB
RFC 2863 The Interfaces Group MIB
RFC 2925 Ping MIB
IEEE 802.1AB Link Layer Discovery Protocol
(LLDP)
RFC 2819 Four groups of RMON: 1 (statistics),
2 (history), 3 (alarm) and 9 (events)
RFC 3176 sFlow
ANSI/TIA-1057 LLDP Media Endpoint Discovery
(LLDP-MED)
SNMPv1/v2c/v3
XRMON
RFC 2328 OSPFv2 (Premium License)
RFC 3101 OSPF NSSA
RFC 2474 DiffServ Precedence, including 8
queues/port
RFC 2597 DiffServ Assured Forwarding (AF)
RFC 2598 DiffServ Expedited Forwarding (EF)
IEEE 802.1X Port Based Network Access Control
RFC 1492 TACACS+
RFC 2865 RADIUS (client only)
RFC 2866 RADIUS Accounting Secure Sockets
Layer (SSL)
SSHv1/SSHv2 Secure Shell
20 RJ-45 auto-sensing 10/100 ports (IEEE 802.3 Type 10Base-T, IEEE
802.3u Type 100Base-TX); Media Type: Auto-MDIX; Duplex: half or full
DA - 13282
Worldwide — Version 3 — August 12, 2009
Page 12
QuickSpecs
HP ProCurve Switch 3500 Series
Technical Specifications
4 dual-personality ports; Each port can be used as either an RJ-45
10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type
100Base-TX; IEEE 802.3ab 1000Base-T Gigabit Ethernet) or an open miniGBIC slot (for use with mini-GBIC transceivers)
Physical characteristics
Memory and processor
Mounting
Performance
Environment
Electrical characteristics
DA - 13282
1 RS-232C DB-9 console port
15.43(d) x 17.44(w) x 1.73(h) in. (39.2 x 44.3 x
Dimensions
4.4 cm) (1U height)
11.9 lb. (5.4 kg)
Weight
10G module
Stackable memory and processor: Freescale
Management Module
PowerPC 8540 @ 666 MHz, 4 MB flash, 128
MB compact flash, 256 MB DDR SDRAM
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware
included); horizontal surface mounting only
100 Mb: < 3.4 µs (FIFO 64-byte packets);
Latency
1000 Mb: < 2.9 µs (FIFO 64-byte packets)
up to 8.9 million pps (64-byte packets)
Throughput
12 Gbps
Routing/Switching
capacity
Switch fabric speed
10,000 entries
Routing table size
MAC address table size 64,000 entries
32ºF to 131ºF (0ºC to 55ºC)
Operating temperature
15% to 95% @ 104ºF (40ºC), non-condensing
Operating relative
humidity
-40ºF to 158ºF (-40ºC to 70ºC)
Non-operating/
Storage temperature
15% to 95% @ 149ºF (65ºC), non-condensing
Non-operating/
Storage relative humidity
up to 15,000 ft. (4.6 km)
Altitude
Power: 52.7 dB, Pressure: 44.8 dB ISO 7779,
Acoustic
ISO 9296
The switch automatically adjusts to any voltage
Description
between 100-127 and 200-240 volts and either
50 or 60 Hz
Maximum heat dissipation 268 BTU/hr (282.8 kJ/hr)
100-127 / 200-240 VAC
Voltage
1.1 / 0.6 A
Current
68.2 W
Idle power
78.7 W
Maximum power rating
PoE power
50 / 60 Hz
Frequency
Idle power is the actual power consumption of
Notes
the device with no ports connected. Maximum
Worldwide — Version 3 — August 12, 2009
Page 13
QuickSpecs
HP ProCurve Switch 3500 Series
Technical Specifications
Safety
Emissions
Immunity
Management
Notes
Services
Standards and protocols
DA - 13282
power rating and maximum heat dissipation are
the worst-case theoretical maximum numbers
provided for planning the infrastructure with fully
loaded PoE (if equipped), 100% traffic, all ports
plugged in, and all modules populated.
CSA 22.2 No. 60950; UL 60950; IEC 60950; EN 60950
FCC Class A; VCCI Class A; EN 55022/CISPR 22 Class A
EN
EN 55024, CISPR 24
ESD
IEC 61000-4-2; 4 kV CD, 8 kV AD
IEC 61000-4-3; 3 V/m
Radiated
IEC 61000-4-4; 1.0 kV (power line), 0.5 kV
EFT/Burst
(signal line)
IEC 61000-4-5; 1 kV/2 kV AC
Surge
IEC 61000-4-6; 3 V
Conducted
IEC 61000-4-8; 1 A/m, 50 or 60 Hz
Power frequency
magnetic field
IEC 61000-4-11; >95% reduction, 0.5 period;
Voltage dips and
interruptions
30% reduction, 25 periods
EN 61000-3-2, IEC 61000-3-2
Harmonics
EN 61000-3-3, IEC 61000-3-3
Flicker
HP ProCurve Manager Plus; HP ProCurve Manager (included); commandline interface; Web browser; configuration menu; out-of-band management
(serial RS-232C)
When using mini-GBICs with this product, mini-GBICs with revision "B" or
later (product number ends with the letter "B" or later, e.g., J4858B, J4859C)
are required.
3-year, 4-hour onsite, 13x5 coverage for hardware (U2855E)
3-year, 4-hour onsite, 24x7 coverage for hardware (U2856E)
3-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone
support (U6304E)
3-year, 24x7 SW phone support, software updates (UE262E)
4-year, 4-hour onsite, 13x5 coverage for hardware (UR868E)
4-year, 4-hour onsite, 24x7 coverage for hardware (UR869E)
4-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone
(UR870E)
4-year, 24x7 SW phone support, software updates (UR871E)
5-year, 4-hour onsite, 13x5 coverage for hardware (UR872E)
5-year, 4-hour onsite, 24x7 coverage for hardware (UR873E)
5-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone
(UR874E)
5-year, 24x7 SW phone support, software updates (UR875E)
Refer to the HP Web site at www.procurve.com/services for details on the
service-level descriptions and product numbers. For details about services
and response times in your area, please contact your local HP sales office.
RFC 1591 DNS (client)
Device Management
HTML and telnet management
IEEE 802.1ad Q-in-Q (Premium License)
General Protocols
Worldwide — Version 3 — August 12, 2009
Page 14
QuickSpecs
HP ProCurve Switch 3500 Series
Technical Specifications
IP Multicast
IPv6
DA - 13282
IEEE 802.1D MAC Bridges
IEEE 802.1p Priority
IEEE 802.1Q VLANs
IEEE 802.1s Multiple Spanning Trees
IEEE 802.1v VLAN classification by Protocol and
Port
IEEE 802.1w Rapid Reconfiguration of Spanning
Tree
IEEE 802.3ad Link Aggregation Control Protocol
(LACP)
IEEE 802.3af Power over Ethernet
IEEE 802.3x Flow Control
RFC 768 UDP
RFC 783 TFTP Protocol (revision 2)
RFC 792 ICMP
RFC 793 TCP
UDLD (Uni-directional Link Detection)
RFC 826 ARP
RFC 854 TELNET
RFC 868 Time Protocol
RFC 951 BOOTP
RFC 1058 RIPv1
RFC 1350 TFTP Protocol (revision 2)
RFC 1519 CIDR
RFC 1542 BOOTP Extensions
RFC 2030 Simple Network Time Protocol (SNTP)
v4
RFC 2131 DHCP
RFC 2453 RIPv2
RFC 2548 (MS-RAS-Vendor only)
RFC 3046 DHCP Relay Agent Information
Option
RFC 3576 Ext to RADIUS (CoA only)
RFC 3768 VRRP (Premium License)
RFC 4675 RADIUS VLAN & Priority
RFC 3376 IGMPv3 (host joins only)
RFC 3973 Draft 2 PIM Dense Mode (Premium
License)
RFC 4601 Draft 10 PIM Sparse Mode (Premium
License)
RFC 1981 IPv6 Path MTU Discovery
RFC 2460 IPv6 Specification
RFC 2710 Multicast Listener Discovery (MLD) for
IPv6
RFC 2925 Remote Operations MIB (Ping only)
RFC 3019 MLDv1 MIB
RFC 3315 DHCPv6 (client only)
RFC 3513 IPv6 Addressing Architecture
RFC 3596 DNS Extension for IPv6
RFC 3810 MLDv2 (host joins only)
RFC 4022 MIB for TCP
Worldwide — Version 3 — August 12, 2009
Page 15
QuickSpecs
HP ProCurve Switch 3500 Series
Technical Specifications
MIBs
Network Management
OSPF
QoS/Cos
Security
DA - 13282
RFC 4113 MIB for UDP
RFC 4251 SSHv6 Architecture
RFC 4252 SSHv6 Authentication
RFC 4253 SSHv6 Transport Layer
RFC 4254 SSHv6 Connection
RFC 4293 MIB for IP
RFC 4419 Key Exchange for SSH
RFC 4443 ICMPv6
RFC 4541 IGMP & MLD Snooping Switch
RFC 4861 IPv6 Neighbor Discovery
RFC 4862 IPv6 Stateless Address Autoconfiguration
RFC 1213 MIB II
RFC 1493 Bridge MIB
RFC 1724 RIPv2 MIB
RFC 1850 OSPFv2 MIB
RFC 2021 RMONv2 MIB
RFC 2096 IP Forwarding Table MIB
RFC 2613 SMON MIB
RFC 2618 RADIUS Client MIB
RFC 2620 RADIUS Accounting MIB
RFC 2665 Ethernet-Like-MIB
RFC 2668 802.3 MAU MIB
RFC 2674 802.1p and IEEE 802.1Q Bridge MIB
RFC 2737 Entity MIB (Version 2)
RFC 2787 VRRP MIB
RFC 2863 The Interfaces Group MIB
RFC 2925 Ping MIB
IEEE 802.1AB Link Layer Discovery Protocol
(LLDP)
RFC 2819 Four groups of RMON: 1 (statistics),
2 (history), 3 (alarm) and 9 (events)
RFC 3176 sFlow
ANSI/TIA-1057 LLDP Media Endpoint Discovery
(LLDP-MED)
SNMPv1/v2c/v3
XRMON
RFC 2328 OSPFv2 (Premium License)
RFC 3101 OSPF NSSA
RFC 2474 DiffServ Precedence, including 8
queues/port
RFC 2597 DiffServ Assured Forwarding (AF)
RFC 2598 DiffServ Expedited Forwarding (EF)
IEEE 802.1X Port Based Network Access Control
RFC 1492 TACACS+
RFC 2865 RADIUS (client only)
RFC 2866 RADIUS Accounting Secure Sockets
Layer (SSL)
SSHv1/SSHv2 Secure Shell
Worldwide — Version 3 — August 12, 2009
Page 16
QuickSpecs
HP ProCurve Switch 3500 Series
Technical Specifications
HP ProCurve 3500-24PoE Switch (J9471A)
Ports
20 RJ-45 auto-sensing 10/100 ports (IEEE 802.3 Type 10Base-T, IEEE
802.3u Type 100Base-TX); Media Type: Auto-MDIX; Duplex: half or full
4 dual-personality ports; each port can be used as either an RJ-45
10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type
100Base-TX; IEEE 802.3ab 1000Base-T Gigabit Ethernet) with PoE or an
open mini-GBIC slot (for use with mini-GBIC transceivers)
Physical characteristics
Memory and processor
Mounting
Performance
Environment
Electrical characteristics
DA - 13282
1 RS-232C DB-9 console port
15.43(d) x 17.44(w) x 1.73(h) in. (39.2 x 44.3 x
Dimensions
4.4 cm) (1U height)
13.23 lb. (6 kg)
Weight
Management Module
Stackable memory and processor: Freescale
PowerPC 8540 @ 666 MHz, 4 MB flash, 128
MB compact flash, 256 MB DDR SDRAM
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware
included); horizontal surface mounting only
100 Mb: < 3.4 µs (FIFO 64-byte packets);
Latency
1000 Mb: < 2.9 µs (FIFO 64-byte packets)
up to 8.9 million pps (64-byte packets)
Throughput
12 Gbps
Routing/Switching
capacity
10,000 entries
Routing table size
MAC address table size 64,000 entries
32ºF to 131ºF (0ºC to 55ºC)
Operating temperature
15% to 95% @ 104ºF (40ºC), non-condensing
Operating relative
humidity
-40ºF to 158ºF (-40ºC to 70ºC)
Non-operating/
Storage temperature
15% to 95% @ 149ºF (65ºC), non-condensing
Non-operating/
Storage relative humidity
up to 15,000 ft. (4.6 km)
Altitude
Power: 52.7 dB, Pressure: 44.8 dB ISO 7779,
Acoustic
ISO 9296
The switch automatically adjusts to any voltage
Description
between 100-127 and 200-240 volts and either
50 or 60 Hz
Maximum heat dissipation 435 BTU/hr (458.92 kJ/hr)
100-127 / 200-240 VAC
Voltage
6.6 / 3.0 A
Current
91 W
Idle power
497 W
Maximum power rating
398 W
PoE power
50 / 60 Hz
Frequency
Idle power is the actual power consumption of
Notes
the device with no ports connected. Maximum
Worldwide — Version 3 — August 12, 2009
Page 17
QuickSpecs
HP ProCurve Switch 3500 Series
Technical Specifications
Safety
Emissions
Immunity
Management
Notes
Services
DA - 13282
power rating and maximum heat dissipation are
the worst-case theoretical maximum
numbers provided for planning the infrastructure
with fully loaded PoE (if equipped), 100% traffic,
all ports plugged in, and all modules populated.
PoE Power is the power supplied by the internal
power supply, it is dependent on the type and
quantity of power supplies and may be
supplemented with the use of a External Power
Supply (EPS).
EN 60950/IEC 60950; CAN/CSA 22.2 No. 60950; EN 60825; UL 60950
FCC Class A; VCCI Class A; EN 55022/CISPR 22 Class A
EN 55024, CISPR 24
EN
IEC 61000-4-2; 4 kV CD, 8 kV AD
ESD
IEC 61000-4-3; 3 V/m
Radiated
IEC 61000-4-4; 1.0 kV (power line), 0.5 kV
EFT/Burst
(signal line)
IEC 61000-4-5; 1 kV/2 kV AC
Surge
IEC 61000-4-6; 3 V
Conducted
IEC 61000-4-8; 1 A/m, 50 or 60 Hz
Power frequency
magnetic field
IEC 61000-4-11; >95% reduction, 0.5 period;
Voltage dips and
interruptions
30% reduction, 25 periods
EN 61000-3-2, IEC 61000-3-2
Harmonics
EN 61000-3-3, IEC 61000-3-3
Flicker
HP ProCurve Manager Plus; HP ProCurve Manager (included); commandline interface; Web browser; configuration menu; out-of-band management
(serial RS-232C)
When using mini-GBICs with this product, mini-GBICs with revision "B" or
later (product number ends with the letter "B" or later, e.g., J4858B, J4859C)
are required.
3-year, 4-hour onsite, 13x5 coverage for hardware (U2855E)
3-year, 4-hour onsite, 24x7 coverage for hardware (U2856E)
3-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone
support (U6304E)
3-year, 24x7 SW phone support, software updates (UE262E)
4-year, 4-hour onsite, 13x5 coverage for hardware (UR868E)
4-year, 4-hour onsite, 24x7 coverage for hardware (UR869E)
4-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone
(UR870E)
4-year, 24x7 SW phone support, software updates (UR871E)
5-year, 4-hour onsite, 13x5 coverage for hardware (UR872E)
5-year, 4-hour onsite, 24x7 coverage for hardware (UR873E)
5-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone
(UR874E)
5-year, 24x7 SW phone support, software updates (UR875E)
Refer to the HP Web site at www.procurve.com/services for details on the
service-level descriptions and product numbers. For details about services
Worldwide — Version 3 — August 12, 2009
Page 18
QuickSpecs
HP ProCurve Switch 3500 Series
Technical Specifications
Standards and protocols
DA - 13282
and response times in your area, please contact your local HP sales office.
RFC 1591 DNS (client)
Device Management
HTML and telnet management
IEEE 802.1ad Q-in-Q (Premium License)
General Protocols
IEEE 802.1D MAC Bridges
IEEE 802.1p Priority
IEEE 802.1Q VLANs
IEEE 802.1s Multiple Spanning Trees
IEEE 802.1v VLAN classification by Protocol and
Port
IEEE 802.1w Rapid Reconfiguration of Spanning
Tree
IEEE 802.3ad Link Aggregation Control Protocol
(LACP)
IEEE 802.3af Power over Ethernet
IEEE 802.3x Flow Control
RFC 768 UDP
RFC 783 TFTP Protocol (revision 2)
RFC 792 ICMP
RFC 793 TCP
UDLD (Uni-directional Link Detection)
RFC 826 ARP
RFC 854 TELNET
RFC 868 Time Protocol
RFC 951 BOOTP
RFC 1058 RIPv1
RFC 1350 TFTP Protocol (revision 2)
RFC 1519 CIDR
RFC 1542 BOOTP Extensions
RFC 2030 Simple Network Time Protocol (SNTP)
v4
RFC 2131 DHCP
RFC 2453 RIPv2
RFC 2548 (MS-RAS-Vendor only)
RFC 3046 DHCP Relay Agent Information
Option
RFC 3576 Ext to RADIUS (CoA only)
RFC 3768 VRRP (Premium License)
RFC 4675 RADIUS VLAN & Priority
RFC 3376 IGMPv3 (host joins only)
IP Multicast
RFC 3973 Draft 2 PIM Dense Mode (Premium
License)
RFC 4601 Draft 10 PIM Sparse Mode (Premium
License)
RFC 1981 IPv6 Path MTU Discovery
IPv6
RFC 2460 IPv6 Specification
RFC 2710 Multicast Listener Discovery (MLD) for
IPv6
RFC 2925 Remote Operations MIB (Ping only)
RFC 3019 MLDv1 MIB
RFC 3315 DHCPv6 (client only)
Worldwide — Version 3 — August 12, 2009
Page 19
QuickSpecs
HP ProCurve Switch 3500 Series
Technical Specifications
MIBs
Network Management
OSPF
QoS/Cos
DA - 13282
RFC 3513 IPv6 Addressing Architecture
RFC 3596 DNS Extension for IPv6
RFC 3810 MLDv2 (host joins only)
RFC 4022 MIB for TCP
RFC 4113 MIB for UDP
RFC 4251 SSHv6 Architecture
RFC 4252 SSHv6 Authentication
RFC 4253 SSHv6 Transport Layer
RFC 4254 SSHv6 Connection
RFC 4293 MIB for IP
RFC 4419 Key Exchange for SSH
RFC 4443 ICMPv6
RFC 4541 IGMP & MLD Snooping Switch
RFC 4861 IPv6 Neighbor Discovery
RFC 4862 IPv6 Stateless Address Autoconfiguration
RFC 1213 MIB II
RFC 1493 Bridge MIB
RFC 1724 RIPv2 MIB
RFC 1850 OSPFv2 MIB
RFC 2021 RMONv2 MIB
RFC 2096 IP Forwarding Table MIB
RFC 2613 SMON MIB
RFC 2618 RADIUS Client MIB
RFC 2620 RADIUS Accounting MIB
RFC 2665 Ethernet-Like-MIB
RFC 2668 802.3 MAU MIB
RFC 2674 802.1p and IEEE 802.1Q Bridge MIB
RFC 2737 Entity MIB (Version 2)
RFC 2787 VRRP MIB
RFC 2863 The Interfaces Group MIB
RFC 2925 Ping MIB
IEEE 802.1AB Link Layer Discovery Protocol
(LLDP)
RFC 2819 Four groups of RMON: 1 (statistics),
2 (history), 3 (alarm) and 9 (events)
RFC 3176 sFlow
ANSI/TIA-1057 LLDP Media Endpoint Discovery
(LLDP-MED)
SNMPv1/v2c/v3
XRMON
RFC 2328 OSPFv2 (Premium License)
RFC 3101 OSPF NSSA
RFC 2474 DiffServ Precedence, including 8
queues/port
RFC 2597 DiffServ Assured Forwarding (AF)
RFC 2598 DiffServ Expedited Forwarding (EF)
Worldwide — Version 3 — August 12, 2009
Page 20
QuickSpecs
HP ProCurve Switch 3500 Series
Technical Specifications
Security
HP ProCurve 3500-48
Switch (J9472A)
Ports
IEEE 802.1X Port Based Network Access Control
RFC 1492 TACACS+
RFC 2865 RADIUS (client only)
RFC 2866 RADIUS Accounting Secure Sockets
Layer (SSL)
SSHv1/SSHv2 Secure Shell
44 RJ-45 auto-sensing 10/100 ports (IEEE 802.3 Type 10Base-T, IEEE
802.3u Type 100Base-TX); Media Type: Auto-MDIX; Duplex: half or full
4 dual-personality ports; each port can be used as either an RJ-45
10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type
100Base-TX; IEEE 802.3ab 1000Base-T Gigabit Ethernet) with PoE or an
open mini-GBIC slot (for use with mini-GBIC transceivers)
Physical characteristics
Memory and processor
Mounting
Performance
Environment
Electrical characteristics
DA - 13282
1 RS-232C DB-9 console port
16.93(d) x 17.44(w) x 1.73(h) in. (43.0 x 44.3 x
Dimensions
4.4 cm) (1U height)
13.45 lb. (7.3 kg)
Weight
Stackable memory and processor: Freescale
Management Module
PowerPC 8540 @ 666 MHz, 4 MB flash Mb,
128 MB compact flash, 256 MB DDR SDRAM
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware
included); horizontal surface mounting only
100 Mb: < 3.4 µs (FIFO 64-byte packets);
Latency
1000 Mb: < 2.9 µs (FIFO 64-byte packets)
up to 12.5 million pps (64-byte packets)
Throughput
16.8 Gbps
Routing/Switching
capacity
10,000 entries
Routing table size
MAC address table size 64,000 entries
32ºF to 131ºF (0ºC to 55ºC)
Operating temperature
15% to 95% @ 104ºF (40ºC), non-condensing
Operating relative
humidity
-40ºF to 158ºF (-40ºC to 70ºC)
Non-operating/
Storage temperature
15% to 95% @ 149ºF (65ºC), non-condensing
Non-operating/
Storage relative humidity
up to 15,000 ft. (4.6 km)
Altitude
Power: 52 dB, Pressure: 45.3 dB ISO 7779, ISO
Acoustic
9296
The switch automatically adjusts to any voltage
Description
between 100-127 and 200-240 volts and either
50 or 60 Hz
Maximum heat dissipation 465 BTU/hr (490.58 kJ/hr)
100-127 / 200-240 VAC
Voltage
Worldwide — Version 3 — August 12, 2009
Page 21
QuickSpecs
HP ProCurve Switch 3500 Series
Technical Specifications
Current
Idle power
Maximum power rating
PoE power
Frequency
Notes
Safety
Emissions
Immunity
Management
Notes
Services
DA - 13282
1.6 / 0.8 A
96 W
136.2 W
50 / 60 Hz
Idle power is the actual power consumption of
the device with no ports connected. Maximum
power rating and maximum heat dissipation are
the worst-case theoretical maximum numbers
provided for planning the infrastructure with fully
loaded PoE (if equipped), 100% traffic, all ports
plugged in, and all modules populated.
EN 60950/IEC 60950; CAN/CSA 22.2 No. 60950; EN 60825; UL 60950
FCC Class A; VCCI Class A; EN 55022/CISPR 22 Class A
EN 55024, CISPR 24
EN
IEC 61000-4-2; 4 kV CD, 8 kV AD
ESD
IEC 61000-4-3; 3 V/m
Radiated
IEC 61000-4-4; 1.0 kV (power line), 0.5 kV
EFT/Burst
(signal line)
IEC 61000-4-5; 1 kV/2 kV AC
Surge
IEC 61000-4-6; 3 V
Conducted
IEC 61000-4-8; 1 A/m, 50 or 60 Hz
Power frequency
magnetic field
IEC 61000-4-11; >95% reduction, 0.5 period;
Voltage dips and
interruptions
30% reduction, 25 periods
EN 61000-3-2, IEC 61000-3-2
Harmonics
EN 61000-3-3, IEC 61000-3-3
Flicker
HP ProCurve Manager Plus; HP ProCurve Manager (included); commandline interface; Web browser; configuration menu; out-of-band management
(serial RS-232C)
When using mini-GBICs with this product, mini-GBICs with revision "B" or
later (product number ends with the letter "B" or later, e.g., J4858B, J4859C)
are required.
3-year, 4-hour onsite, 13x5 coverage for hardware (H4496E)
3-year, 4-hour onsite, 24x7 coverage for hardware (H2893E)
3-year, 4-hour onsite, 24x7 coverage for hardware,24x7 software phone
support (U6319E)
3-year, 24x7 SW phone support, software updates (UE264E)
4-year, 4-hour onsite, 13x5 coverage for hardware (UR884E)
4-year, 4-hour onsite, 24x7 coverage for hardware (UR885E)
4-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone
(UR886E)
4-year, 24x7 SW phone support, software updates (UR887E)
5-year, 4-hour onsite, 13x5 coverage for hardware (UR888E)
5-year, 4-hour onsite, 24x7 coverage for hardware (UR889E)
5-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone
Worldwide — Version 3 — August 12, 2009
Page 22
QuickSpecs
HP ProCurve Switch 3500 Series
Technical Specifications
(UR890E)
5-year, 24x7 SW phone support, software updates (UR891E)
Standards and protocols
DA - 13282
Refer to the HP Web site at www.procurve.com/services for details on the
service-level descriptions and product numbers. For details about services
and response times in your area, please contact your local HP sales office.
RFC 1591 DNS (client)
Device Management
HTML and telnet management
IEEE 802.1ad Q-in-Q (Premium License)
General Protocols
IEEE 802.1D MAC Bridges
IEEE 802.1p Priority
IEEE 802.1Q VLANs
IEEE 802.1s Multiple Spanning Trees
IEEE 802.1v VLAN classification by Protocol and
Port
IEEE 802.1w Rapid Reconfiguration of Spanning
Tree
IEEE 802.3ad Link Aggregation Control Protocol
(LACP)
IEEE 802.3af Power over Ethernet
IEEE 802.3x Flow Control
RFC 768 UDP
RFC 783 TFTP Protocol (revision 2)
RFC 792 ICMP
RFC 793 TCP
UDLD (Uni-directional Link Detection)
RFC 826 ARP
RFC 854 TELNET
RFC 868 Time Protocol
RFC 951 BOOTP
RFC 1058 RIPv1
RFC 1350 TFTP Protocol (revision 2)
RFC 1519 CIDR
RFC 1542 BOOTP Extensions
RFC 2030 Simple Network Time Protocol (SNTP)
v4
RFC 2131 DHCP
RFC 2453 RIPv2
RFC 2548 (MS-RAS-Vendor only)
RFC 3046 DHCP Relay Agent Information
Option
RFC 3576 Ext to RADIUS (CoA only)
RFC 3768 VRRP (Premium License)
RFC 4675 RADIUS VLAN & Priority
RFC 3376 IGMPv3 (host joins only)
IP Multicast
RFC 3973 Draft 2 PIM Dense Mode (Premium
License)
RFC 4601 Draft 10 PIM Sparse Mode (Premium
License)
RFC 1981 IPv6 Path MTU Discovery
IPv6
RFC 2460 IPv6 Specification
Worldwide — Version 3 — August 12, 2009
Page 23
QuickSpecs
HP ProCurve Switch 3500 Series
Technical Specifications
MIBs
Network Management
OSPF
DA - 13282
RFC 2710 Multicast Listener Discovery (MLD) for
IPv6
RFC 2925 Remote Operations MIB (Ping only)
RFC 3019 MLDv1 MIB
RFC 3315 DHCPv6 (client only)
RFC 3513 IPv6 Addressing Architecture
RFC 3596 DNS Extension for IPv6
RFC 3810 MLDv2 (host joins only)
RFC 4022 MIB for TCP
RFC 4113 MIB for UDP
RFC 4251 SSHv6 Architecture
RFC 4252 SSHv6 Authentication
RFC 4253 SSHv6 Transport Layer
RFC 4254 SSHv6 Connection
RFC 4293 MIB for IP
RFC 4419 Key Exchange for SSH
RFC 4443 ICMPv6
RFC 4541 IGMP & MLD Snooping Switch
RFC 4861 IPv6 Neighbor Discovery
RFC 4862 IPv6 Stateless Address Autoconfiguration
RFC 1213 MIB II
RFC 1493 Bridge MIB
RFC 1724 RIPv2 MIB
RFC 1850 OSPFv2 MIB
RFC 2021 RMONv2 MIB
RFC 2096 IP Forwarding Table MIB
RFC 2613 SMON MIB
RFC 2618 RADIUS Client MIB
RFC 2620 RADIUS Accounting MIB
RFC 2665 Ethernet-Like-MIB
RFC 2668 802.3 MAU MIB
RFC 2674 802.1p and IEEE 802.1Q Bridge MIB
RFC 2737 Entity MIB (Version 2)
RFC 2787 VRRP MIB
RFC 2863 The Interfaces Group MIB
RFC 2925 Ping MIB
IEEE 802.1AB Link Layer Discovery Protocol
(LLDP)
RFC 2819 Four groups of RMON: 1 (statistics),
2 (history), 3 (alarm) and 9 (events)
RFC 3176 sFlow
ANSI/TIA-1057 LLDP Media Endpoint Discovery
(LLDP-MED)
SNMPv1/v2c/v3
XRMON
RFC 2328 OSPFv2 (Premium License)
RFC 3101 OSPF NSSA
Worldwide — Version 3 — August 12, 2009
Page 24
QuickSpecs
HP ProCurve Switch 3500 Series
Technical Specifications
QoS/Cos
Security
HP ProCurve 3500-48PoE Switch (J9473A)
Ports
RFC 2474 DiffServ Precedence, including 8
queues/port
RFC 2597 DiffServ Assured Forwarding (AF)
RFC 2598 DiffServ Expedited Forwarding (EF)
IEEE 802.1X Port Based Network Access Control
RFC 1492 TACACS+
RFC 2865 RADIUS (client only)
RFC 2866 RADIUS Accounting Secure Sockets
Layer (SSL)
SSHv1/SSHv2 Secure Shell
44 RJ-45 auto-sensing 10/100 ports (IEEE 802.3 Type 10Base-T, IEEE
802.3u Type 100Base-TX); Media Type: Auto-MDIX; Duplex: half or full
4 dual-personality ports; each port can be used as either an RJ-45
10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type
100Base-TX; IEEE 802.3ab 1000Base-T Gigabit Ethernet) with PoE or an
open mini-GBIC slot (for use with mini-GBIC transceivers)
Physical characteristics
Memory and processor
Mounting
Performance
Environment
Electrical characteristics
DA - 13282
1 RS-232C DB-9 console port
16.93(d) x 17.44(w) x 1.73(h) in. (43.0 x 44.3 x
Dimensions
4.4 cm) (1U height)
16.09 lb. (7.3 kg)
Weight
Stackable memory and processor: Freescale
Management Module
PowerPC 8540 @ 666 MHz, 4 MB flash Mb,
128 MB compact flash, 256 MB DDR SDRAM
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware
included); horizontal surface mounting only
100 Mb: < 3.4 µs (FIFO 64-byte packets);
Latency
1000 Mb: < 2.9 µs (FIFO 64-byte packets)
up to 12.5 million pps (64-byte packets)
Throughput
16.8 Gbps
Routing/Switching
capacity
10,000 entries
Routing table size
MAC address table size 64,000 entries
32ºF to 131ºF (0ºC to 55ºC)
Operating temperature
15% to 95% @ 104ºF (40ºC), non-condensing
Operating relative
humidity
-40ºF to 158ºF (-40ºC to 70ºC)
Non-operating/
Storage temperature
15% to 95% @ 149ºF (65ºC), non-condensing
Non-operating/
Storage relative humidity
up to 15,000 ft. (4.6 km)
Altitude
Power: 55.1 dB, Pressure: 45.3 dB ISO 7779,
Acoustic
ISO 9296
The switch automatically adjusts to any voltage
Description
Worldwide — Version 3 — August 12, 2009
Page 25
QuickSpecs
HP ProCurve Switch 3500 Series
Technical Specifications
Safety
Emissions
Immunity
Management
Notes
Services
DA - 13282
between 100-127 and 200-240 volts and either
50 or 60 Hz
Maximum heat dissipation 611 BTU/hr (644.6 kJ/hr)
Voltage
100-127 / 200-240 VAC
Current
7.3 / 3.3 A
133.2 W
Idle power
548.8 W
Maximum power rating
398 W
PoE power
50 / 60 Hz
Frequency
Idle power is the actual power consumption of
Notes
the device with no ports connected. Maximum
power rating and maximum heat dissipation are
the worst-case theoretical maximum numbers
provided for planning the infrastructure with fully
loaded PoE (if equipped), 100% traffic, all ports
plugged in, and all modules populated. PoE
Power is the power supplied by the internal
power supply, it is dependent on the type and
quantity of power supplies and may be
supplemented with the use of a External Power
Supply (EPS).
EN 60950/IEC 60950; CAN/CSA 22.2 No. 60950; EN 60825; UL 60950
FCC Class A; VCCI Class A; EN 55022/CISPR 22 Class A
EN 55024, CISPR 24
EN
IEC 61000-4-2; 4 kV CD, 8 kV AD
ESD
IEC 61000-4-3; 3 V/m
Radiated
IEC 61000-4-4; 1.0 kV (power line), 0.5 kV
EFT/Burst
(signal line)
IEC 61000-4-5; 1 kV/2 kV AC
Surge
IEC 61000-4-6; 3 V
Conducted
IEC 61000-4-8; 1 A/m, 50 or 60 Hz
Power frequency
magnetic field
IEC 61000-4-11; >95% reduction, 0.5 period;
Voltage dips and
interruptions
30% reduction, 25 periods
EN 61000-3-2, IEC 61000-3-2
Harmonics
EN 61000-3-3, IEC 61000-3-3
Flicker
HP ProCurve Manager Plus; HP ProCurve Manager (included); commandline interface; Web browser; configuration menu; out-of-band management
(serial RS-232C)
When using mini-GBICs with this product, mini-GBICs with revision "B" or
later (product number ends with the letter "B" or later, e.g., J4858B, J4859C)
are required.
3-year, 4-hour onsite, 13x5 coverage for hardware (H4496E)
3-year, 4-hour onsite, 24x7 coverage for hardware (H2893E)
3-year, 4-hour onsite, 24x7 coverage for hardware,24x7 software phone
support (U6319E)
Worldwide — Version 3 — August 12, 2009
Page 26
QuickSpecs
HP ProCurve Switch 3500 Series
Technical Specifications
3-year, 24x7 SW phone support, software updates (UE264E)
4-year, 4-hour onsite, 13x5 coverage for hardware (UR884E)
4-year, 4-hour onsite, 24x7 coverage for hardware (UR885E)
4-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone
(UR886E)
4-year, 24x7 SW phone support, software updates (UR887E)
5-year, 4-hour onsite, 13x5 coverage for hardware (UR888E)
5-year, 4-hour onsite, 24x7 coverage for hardware (UR889E)
5-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone
(UR890E)
5-year, 24x7 SW phone support, software updates (UR891E)
Standards and protocols
DA - 13282
Refer to the HP Web site at www.procurve.com/services for details on the
service-level descriptions and product numbers. For details about services
and response times in your area, please contact your local HP sales office.
RFC 1591 DNS (client)
Device Management
HTML and telnet management
IEEE 802.1ad Q-in-Q (Premium License)
General Protocols
IEEE 802.1D MAC Bridges
IEEE 802.1p Priority
IEEE 802.1Q VLANs
IEEE 802.1s Multiple Spanning Trees
IEEE 802.1v VLAN classification by Protocol and
Port
IEEE 802.1w Rapid Reconfiguration of Spanning
Tree
IEEE 802.3ad Link Aggregation Control Protocol
(LACP)
IEEE 802.3af Power over Ethernet
IEEE 802.3x Flow Control
RFC 768 UDP
RFC 783 TFTP Protocol (revision 2)
RFC 792 ICMP
RFC 793 TCP
UDLD (Uni-directional Link Detection)
RFC 826 ARP
RFC 854 TELNET
RFC 868 Time Protocol
RFC 951 BOOTP
RFC 1058 RIPv1
RFC 1350 TFTP Protocol (revision 2)
RFC 1519 CIDR
RFC 1542 BOOTP Extensions
RFC 2030 Simple Network Time Protocol (SNTP)
v4
RFC 2131 DHCP
RFC 2453 RIPv2
RFC 2548 (MS-RAS-Vendor only)
RFC 3046 DHCP Relay Agent Information
Option
RFC 3576 Ext to RADIUS (CoA only)
Worldwide — Version 3 — August 12, 2009
Page 27
QuickSpecs
HP ProCurve Switch 3500 Series
Technical Specifications
IP Multicast
IPv6
MIBs
Network Management
DA - 13282
RFC 3768 VRRP (Premium License)
RFC 4675 RADIUS VLAN & Priority
RFC 3376 IGMPv3 (host joins only)
RFC 3973 Draft 2 PIM Dense Mode (Premium
License)
RFC 4601 Draft 10 PIM Sparse Mode (Premium
License)
RFC 1981 IPv6 Path MTU Discovery
RFC 2460 IPv6 Specification
RFC 2710 Multicast Listener Discovery (MLD) for
IPv6
RFC 2925 Remote Operations MIB (Ping only)
RFC 3019 MLDv1 MIB
RFC 3315 DHCPv6 (client only)
RFC 3513 IPv6 Addressing Architecture
RFC 3596 DNS Extension for IPv6
RFC 3810 MLDv2 (host joins only)
RFC 4022 MIB for TCP
RFC 4113 MIB for UDP
RFC 4251 SSHv6 Architecture
RFC 4252 SSHv6 Authentication
RFC 4253 SSHv6 Transport Layer
RFC 4254 SSHv6 Connection
RFC 4293 MIB for IP
RFC 4419 Key Exchange for SSH
RFC 4443 ICMPv6
RFC 4541 IGMP & MLD Snooping Switch
RFC 4861 IPv6 Neighbor Discovery
RFC 4862 IPv6 Stateless Address Autoconfiguration
RFC 1213 MIB II
RFC 1493 Bridge MIB
RFC 1724 RIPv2 MIB
RFC 1850 OSPFv2 MIB
RFC 2021 RMONv2 MIB
RFC 2096 IP Forwarding Table MIB
RFC 2613 SMON MIB
RFC 2618 RADIUS Client MIB
RFC 2620 RADIUS Accounting MIB
RFC 2665 Ethernet-Like-MIB
RFC 2668 802.3 MAU MIB
RFC 2674 802.1p and IEEE 802.1Q Bridge MIB
RFC 2737 Entity MIB (Version 2)
RFC 2787 VRRP MIB
RFC 2863 The Interfaces Group MIB
RFC 2925 Ping MIB
IEEE 802.1AB Link Layer Discovery Protocol
(LLDP)
RFC 2819 Four groups of RMON: 1 (statistics),
2 (history), 3 (alarm) and 9 (events)
RFC 3176 sFlow
Worldwide — Version 3 — August 12, 2009
Page 28
QuickSpecs
HP ProCurve Switch 3500 Series
Technical Specifications
OSPF
QoS/Cos
Security
DA - 13282
ANSI/TIA-1057 LLDP Media Endpoint Discovery
(LLDP-MED)
SNMPv1/v2c/v3
XRMON
RFC 2328 OSPFv2 (Premium License)
RFC 3101 OSPF NSSA
RFC 2474 DiffServ Precedence, including 8
queues/port
RFC 2597 DiffServ Assured Forwarding (AF)
RFC 2598 DiffServ Expedited Forwarding (EF)
IEEE 802.1X Port Based Network Access Control
RFC 1492 TACACS+
RFC 2865 RADIUS (client only)
RFC 2866 RADIUS Accounting Secure Sockets
Layer (SSL)
SSHv1/SSHv2 Secure Shell
Worldwide — Version 3 — August 12, 2009
Page 29
QuickSpecs
HP ProCurve Switch 3500 Series
Accessories
HP ProCurve Switch
Premium License for Switch 3500 Series
3500yl Series accessories HP ProCurve 620 Redundant/External Power Supply
HP ProCurve 100-FX SFP-LC Transceiver
NEW HP ProCurve 100-BX-D SFP-LC Transceiver
NEW HP ProCurve 100-BX-U SFP-LC Transceiver
HP ProCurve Gigabit-SX-LC Mini-GBIC
HP ProCurve Gigabit-LX-LC Mini-GBIC
HP ProCurve Gigabit-LH-LC Mini-GBIC
NEW HP ProCurve 1000-BX-D SFP-LC Mini-GBIC
NEW HP ProCurve 1000-BX-U SFP-LC Mini-GBIC
yl Modules
J8993A
J8696A
J9054B
J9099B
J9100B
J4858C
J4859C
J4860C
J9142B
J9143B
HP ProCurve 10-GbE X2-SC SR Optic
NEW HP ProCurve 10-GbE X2-SC LRM Optic
HP ProCurve 10-GbE X2-SC LR Optic
HP ProCurve 10-GbE X2-SC ER Optic
HP ProCurve 10-GbE X2-CX4 Transceiver
HP ProCurve 10-GbE CX4 Media Converter
HP ProCurve Manager 3.0
J8436A
J9144A
J8437A
J8438A
J8440B
J8439A
-
HP ProCurve Switch yl 10-GbE 2-Port CX4 + 2-Port X2 Module
J8694A
© Copyright 2009 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without
notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products
and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or
editorial errors or omissions contained herein.
To learn more, visit: www.hp.com/go/procurve
Information is subject to change without notice
DA - 13282
Worldwide — Version 3 — August 12, 2009
Page 30

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement