X9DRFF-iG+
X9DRFF-iTG+
X9DRFF-7G+
X9DRFF-7TG+
USER’S MANUAL
Revision 1.0b
The information in this User’s Manual has been carefully reviewed and is believed to be accurate.
The vendor assumes no responsibility for any inaccuracies that may be contained in this document,
and makes no commitment to update or to keep current the information in this manual, or to notify
any person or organization of the updates. Please Note: For the most up-to-date version of this
manual, please see our Website at www.supermicro.com.
Super Micro Computer, Inc. ("Supermicro") reserves the right to make changes to the product
described in this manual at any time and without notice. This product, including software and documentation, is the property of Supermicro and/or its licensors, and is supplied only under a license.
Any use or reproduction of this product is not allowed, except as expressly permitted by the terms
of said license.
IN NO EVENT WILL SUPER MICRO COMPUTER, INC. BE LIABLE FOR DIRECT, INDIRECT,
SPECIAL, INCIDENTAL, SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE
USE OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF
THE POSSIBILITY OF SUCH DAMAGES. IN PARTICULAR, SUPER MICRO COMPUTER, INC.
SHALL NOT HAVE LIABILITY FOR ANY HARDWARE, SOFTWARE, OR DATA STORED OR USED
WITH THE PRODUCT, INCLUDING THE COSTS OF REPAIRING, REPLACING, INTEGRATING,
INSTALLING OR RECOVERING SUCH HARDWARE, SOFTWARE, OR DATA.
Any disputes arising between the manufacturer and the customer shall be governed by the laws of
Santa Clara County in the State of California, USA. The State of California, County of Santa Clara
shall be the exclusive venue for the resolution of any such disputes. Supermicro's total liability for
all claims will not exceed the price paid for the hardware product.
FCC Statement: This equipment has been tested and found to comply with the limits for a Class
A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the manufacturer’s instruction manual, may cause harmful
interference with radio communications. Operation of this equipment in a residential area is likely
to cause harmful interference, in which case you will be required to correct the interference at your
own expense.
California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate
warning applies only to products containing CR (Manganese Dioxide) Lithium coin cells. “Perchlorate
Material-special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate”.
WARNING: Handling of lead solder materials used in this
product may expose you to lead, a chemical known to
the State of California to cause birth defects and other
reproductive harm.
Manual Revision 1.0b
Release Date: October 30, 2013
Unless you request and receive written permission from Super Micro Computer, Inc., you may not
copy any part of this document.
Information in this document is subject to change without notice. Other products and companies
referred to herein are trademarks or registered trademarks of their respective companies or mark
holders.
Copyright © 2013 by Super Micro Computer, Inc.
All rights reserved.
Printed in the United States of America
Preface
Preface
This manual is written for system integrators, PC technicians and
knowledgeable PC users. It provides information for the installation and use of the
X9DRFF-iG+/iTG+/7G+/7TG+ motherboard.
About This Motherboard
The Super X9DRFF-iG+/iTG+/7G+/7TG+ motherboard supports dual Intel E5-2600
(v2) Series Processors (Socket R LGA 2011) that offer QPI (Intel QuickPath Interface) Technology (V.1.1), providing point-to-point connection with a transfer speed
of up to 8.0 TG/s. With the C602 chipset built in, the X9DRFF-iG+/iTG+/7G+/7TG+
motherboard supports Intel® Intelligent Power Node Manager (NM), Management
Engine (ME) Technology, Digital Media Interface (DMI), PCI-E Gen. 3.0 and up
to 1866 MHz DDR3 memory. This motherboard is ideal for SMCI Fat Twin server
platforms. Please refer to our Website (http://www.supermicro.com) for GPU and
memory support updates.
Manual Organization
Chapter 1 describes the features, specifications and performance of the motherboard. It also provides detailed information about Intel C602 chipset.
Chapter 2 provides hardware installation instructions. Read this chapter when installing the processor, memory modules and other hardware components into the
system. If you encounter any problems, see Chapter 3, which describes troubleshooting procedures for video, memory, and system setup stored in the CMOS.
Chapter 4 includes an introduction to the BIOS, and provides detailed instructions
on how to run the CMOS Setup utility.
Appendix A provides BIOS Error Beep Codes.
Appendix B lists Software Installation Instructions.
iii
X9DRFF-iG+/iTG+/7G+/7TG+ Motherboard User’s Manual
Conventions Used in the Manual
Pay special attention to the following symbols for proper system installation and to
prevent damage to the system or injury to yourself:
Warning: Important information given to ensure proper system installation or to prevent
damage to the components
Note: Additional information given to differentiate between various models
or provides information for correct system setup.
iv
Preface
Contacting Supermicro
Headquarters
Address:
Super Micro Computer, Inc.
980 Rock Ave.
San Jose, CA 95131 U.S.A.
Tel:
+1 (408) 503-8000
Fax:
+1 (408) 503-8008
Email:
marketing@supermicro.com (General Information)
support@supermicro.com (Technical Support)
Web Site:
www.supermicro.com
Europe
Address:
Super Micro Computer B.V.
Het Sterrenbeeld 28, 5215 ML
's-Hertogenbosch, The Netherlands
Tel:
+31 (0) 73-6400390
Fax:
+31 (0) 73-6416525
Email:
sales@supermicro.nl (General Information)
support@supermicro.nl (Technical Support)
rma@supermicro.nl (Customer Support)
Asia-Pacific
Address:
Super Micro Computer, Inc.
3F, No. 150, Jian 1st Rd.
Zhonghe Dist., New Taipei City 23511
Taiwan (R.O.C)
Tel:
+886-(2) 8226-3990
Fax:
+886-(2) 8226-3992
Web Site:
www.supermicro.com.tw
Technical Support:
Email:
support@supermicro.com.tw
Tel: +886-(2)-8226-3990
v
X9DRFF-iG+/iTG+/7G+/7TG+ Motherboard User’s Manual
Table of Contents
Preface
Chapter 1 Overview
1-1 Overview.......................................................................................................... 1-1
1-2 Processor and Chipset Overview...................................................................1-11
1-3 Special Features............................................................................................ 1-12
1-4 PC Health Monitoring..................................................................................... 1-12
1-5 ACPI Features................................................................................................ 1-13
1-6 Power Supply................................................................................................. 1-13
1-7 Super I/O........................................................................................................ 1-14
1-8 Advanced Power Management...................................................................... 1-14
Intel® Intelligent Power Node Manager (IPNM)............................................. 1-14
Management Engine (ME)............................................................................. 1-14
1-9 Overview of the Nuvoton WPCM450 Controller ........................................... 1-15
WPCM450R DDR2 Memory Interface........................................................... 1-15
WPCM450R PCI System Interface................................................................ 1-15
Other Features Supported by the WPCM BMC Controller............................ 1-15
Chapter 2 Installation
2-1
Standardized Warning Statements.................................................................. 2-1
Battery Handling............................................................................................... 2-1
Product Disposal.............................................................................................. 2-3
2-2 Static-Sensitive Devices................................................................................... 2-4
Precautions...................................................................................................... 2-4
Unpacking........................................................................................................ 2-4
2-3 Processor and Heatsink Installation................................................................ 2-5
Installing the LGA2011 Processor .................................................................. 2-5
Installing a Passive CPU Heatsink.................................................................. 2-9
Removing the Heatsink.................................................................................. 2-10
2-4 Installing and Removing the Memory Modules...............................................2-11
Installing & Removing DIMMs.........................................................................2-11
Removing Memory Modules...........................................................................2-11
2-5 Motherboard Installation................................................................................. 2-16
Tools Needed................................................................................................. 2-16
Location of Mounting Holes........................................................................... 2-16
Installing the Motherboard............................................................................. 2-17
2-6 Control Panel Connectors and I/O Ports....................................................... 2-18
Front Panel Connectors and I/O Ports.......................................................... 2-18
vi
Table of Contents
Front Panel I/O Port Locations and Definitions ............................................ 2-18
Universal Serial Bus (USB)....................................................................... 2-19
Video Connection...................................................................................... 2-19
Ethernet Ports........................................................................................... 2-20
Power Button/Unit Identifier Switch........................................................... 2-21
2-7 Connecting Cables......................................................................................... 2-22
Fan Headers.............................................................................................. 2-23
IPMB.......................................................................................................... 2-24
SATA Device Power Connector................................................................. 2-24
T-SGPIO 1/2 & 6-SGPIO 1/2 Headers...................................................... 2-25
Power SMB (I2C) Connector..................................................................... 2-25
Power Switch............................................................................................. 2-26
Unit Identification Switch/LED................................................................... 2-26
2-8 Jumper Settings............................................................................................. 2-27
Explanation of Jumpers................................................................................. 2-27
GLAN Enable/Disable............................................................................... 2-27
CMOS Clear.............................................................................................. 2-28
Watch Dog Enable/Disable....................................................................... 2-28
VGA Enable............................................................................................... 2-29
BMC Enable ............................................................................................. 2-29
Management Engine (ME) Recovery ....................................................... 2-30
Manufacture Mode Select......................................................................... 2-30
SAS Enable (For X9DRFF-7G+/7TG+)..................................................... 2-31
2-9 Onboard LED Indicators................................................................................ 2-32
GLAN LEDs............................................................................................... 2-32
IPMI Dedicated LAN LEDs........................................................................ 2-32
HDD Activity LED...................................................................................... 2-33
BMC Heartbeat LED................................................................................. 2-33
SAS Heartbeat LED.................................................................................. 2-34
Failure LED............................................................................................... 2-34
UID LED.................................................................................................... 2-35
2-10 SATA/SAS Connections................................................................................. 2-36
SATA/SAS Ports........................................................................................ 2-36
Chapter 3 Troubleshooting
3-1 Troubleshooting Procedures............................................................................ 3-1
3-2 Technical Support Procedures......................................................................... 3-4
3-3
Battery Removal and Installation..................................................................... 3-5
vii
X9DRFF-iG+/iTG+/7G+/7TG+ Motherboard User’s Manual
3-4 Frequently Asked Questions............................................................................ 3-6
3-5 Returning Merchandise for Service................................................................. 3-7
Chapter 4 BIOS
4-1 Introduction....................................................................................................... 4-1
4-2 Main Setup....................................................................................................... 4-2
4-3 Advanced Setup Configurations...................................................................... 4-4
4-4 Event Logs..................................................................................................... 4-23
4-5 IPMI................................................................................................................ 4-25
4-6 Boot................................................................................................................ 4-27
4-7 Security.......................................................................................................... 4-28
4-8 Save & Exit.................................................................................................... 4-29
Appendix A BIOS Error Beep Codes
Appendix B Software Installation Instructions
B-1 Installing Software Programs...........................................................................B-1
B-2 Configuring SuperDoctor® III...........................................................................B-2
viii
Chapter 1: Overview
Chapter 1
Overview
1-1 Overview
Checklist
Congratulations on purchasing your computer motherboard from an acknowledged
leader in the industry. Supermicro boards are designed with the utmost attention to
detail to provide you with the highest standards in quality and performance.
This motherboard was designed to be used in an SMC-proprietary system as a part
of an integrated system platform.
Note: For your system to work properly, please follow the links below to
download all necessary drivers/utilities and the user's manual for your
motherboard.
SMCI product manuals: http://www.supermicro.com/support/manuals/
Product Drivers and utilities: ftp://ftp.supermicro.com/
If you have any questions, please contact our support team at support@supermicro.
com.
1-1
X9DRFF-iG+/iTG+/7G+/7TG+ Motherboard User’s Manual
Motherboard Image
Note: All graphics shown in this manual were based upon the latest PCB
Revision available at the time of publishing of the manual. The motherboard
you've received may or may not look exactly the same as the graphics
shown in this manual.
1-2
Chapter 1: Overview
Motherboard Layout
JPG1
JPB1
USB1
LAN2
MEGERAC LICENSE
Intel PCH
SAS CODE
LEDS2
JBT1
JPS1
X9DRFF-iG+
IPMI CODE
MAC CODE
CPLD1
BIOS
HDD_ACT_LED1
BMC
PCH SLOT4 PCIE-E 2.0X4
BMC_HB_LED1
JP6
JBR1
JIPMB1 JPI2C1
CPU1 SLOT3 PCI-E 3.0X8
1
LSI SAS
CTRL
Rev. 1.01
JBAT1
JSD1
6-SGPIO2
6-SGPIO1
T-SGPIO2
T-SGPIO1
P1-DIMMA1
P1-DIMMA2
P1-DIMMB1
I-SATA5
I-SATA4
I-SATA3
I-SATA2
CPU1
CLOSE 1st
L-SAS6
L-SAS4
L-SAS2
L-SAS0
I-SATA0 I-SATA1
P1-DIMMD2
P1-DIMMD1
HDD_PWR2
P1-DIMMB2
P1-DIMMC1
P1-DIMMC2
CPU1 SLOT2 PCI-E 3.0X8
CPU1 SLOT1 PCI-E X16 PROPRIETARY SLOT
JP7
JWD1
JI2C2
JI2C1
USB2
IPMI_ LAN
LAN1
JPME2
USB0
PWR_SW1
UID_SW1
UID_LED1
FAILURE_LED1
JPL1
Intel LAN
CTRL
JPME1
VGA1
L-SAS7
L-SAS5
L-SAS3
L-SAS1
OPEN 1st
P2-DIMME2
P2-DIMMF2
P2-DIMMF1
P2-DIMME1
P2-DIMMH1
P2-DIMMH2
SXB1:CPU2 PCI-E X32
PROPRIENTAR SLOT
P2-DIMMG2
P2-DIMMG1
JPW3
CPU2
Rear_FAN
PS_ON_N
JPW2
CLOSE 1st
OPEN 1st
FAN2
FAN3
FAN4
FAN5
FAN6
FAN1
FAN8
FAN7
HDD
JPW1 PWR1
Note 1: For the latest CPU/Memory updates, please refer to our Website
at http://www.supermicro.com/products/motherboard/ for details.
Note 2: Changing BMC log-in information is recommended during initial
system power-on. The default username is ADMIN and password is
ADMIN. For BMC best practices, please refer to: http://www.supermicro.
com/products/nfo/files/IPMI/Best_Practices_BMC_Security.pdf
1-3
X9DRFF-iG+/iTG+/7G+/7TG+ Motherboard User’s Manual
X9DRFF-iG+/iTG+/7G+/7TG+ Quick Reference
JPG1
JPB1
USB1
LAN2
MEGERAC LICENSE
Intel PCH
SAS CODE
LEDS2
JBT1
JPS1
X9DRFF-iG+
IPMI CODE
MAC CODE
CPLD1
BIOS
HDD_ACT_LED1
BMC
PCH SLOT4 PCIE-E 2.0X4
BMC_HB_LED1
JP6
JBR1
JIPMB1 JPI2C1
CPU1 SLOT3 PCI-E 3.0X8
1
LSI SAS
CTRL
Rev. 1.01
JBAT1
JSD1
6-SGPIO2
6-SGPIO1
T-SGPIO2
T-SGPIO1
P1-DIMMA1
P1-DIMMA2
I-SATA5 L-SAS6 L-SAS7
I-SATA4 L-SAS4 L-SAS5
I-SATA3 L-SAS2 L-SAS3
I-SATA2 L-SAS0 L-SAS1
I-SATA0 I-SATA1
P1-DIMMD2
P1-DIMMD1
HDD_PWR2
P1-DIMMB2
P1-DIMMB1
P1-DIMMC1
P1-DIMMC2
CPU1 SLOT2 PCI-E 3.0X8
CPU1 SLOT1 PCI-E X16 PROPRIETARY SLOT
JP7
JWD1
JI2C2
JI2C1
USB2
IPMI_ LAN
LAN1
JPME2
USB0
PWR_SW1
UID_SW1
UID_LED1
FAILURE_LED1
JPL1
Intel LAN
CTRL
JPME1
VGA1
CPU1
CLOSE 1st
OPEN 1st
P2-DIMMF2
P2-DIMME2
P2-DIMMF1
P2-DIMME1
SXB1:CPU2 PCI-E X32
PROPRIENTAR SLOT
P2-DIMMH1
P2-DIMMH2
P2-DIMMG2
P2-DIMMG1
JPW3
CPU2
Rear_FAN
PS_ON_N
JPW2
CLOSE 1st
OPEN 1st
FAN2
FAN3
FAN4
FAN5
FAN6
FAN1
FAN8
FAN7
HDD
JPW1 PWR1
Notes:
•See Chapter 2 for detailed information on jumpers, I/O ports and JF1 front
panel connections.
•"
" indicates the location of "Pin 1".
•Jumpers/LED Indicators not indicated are for testing only.
•Use only the correct type of onboard CMOS battery as specified by the manufac-
turer. Do not install the onboard battery upside down to avoid possible explosion.
1-4
Chapter 1: Overview
X9DRFF-iG+/iTG+/7G+/7TG+ Jumpers
Jumper
Description
Default Setting
JBT1
Clear CMOS
See Chapter 2
JI2C1/JI2C2
SMB to PCI-E Slots
Open (Disabled)
JPB1
BMC Enable
Pins 1-2 (Enabled)
JPG1
VGA Enable
Pins 1-2 (Enabled)
JPL1
LAN1/LAN2 Enable
Pins 1-2 (Enabled)
JPME1
Management Engine (ME) Recovery
Mode
Pins 1-2 (Normal)
JPME2
Management Engine (ME)
Manufacture Mode
Pins 1-2 (Normal)
JPS1
SAS Enable (7G+/7TG+ Only)
Pins 1-2 (Enabled)
JWD1
Watch Dog Timer Enable
Pins 1-2 (Reset)
X9DRFF-iG+/iTG+/7G+/7TG+ Connectors
Connectors
Description
FAN1-FAN8,
Rear_FAN1
CPU/System/Cooling Fan Headers
HDD_PWR1/HDD_PWR2
8-pin Power Supply Connectors for HDD Device Use
JBAT1
Onboard CMOS Battery (See Chpt. 3 for Battery Disposal)
JIPMB1
4-pin External BMC I2C Header (for an IPMI Card)
JPI2C1
Power Supply SMBbus I2C Header
JPW1/JPW2
8-pin Power Connectors
JPW3
4-pin Power Connector (PS_ON_N)
JSD1
SATA Device Power Connector
JTPM1
TPM (Trusted Platform Module)/Port 80 Connector
LAN1/LAN2
G-bit Ethernet LAN Ports 1/2 (X9DRFF-iG+/7G+),
10 G_bit LAN Ports 1/2 (X9DRFF-iTG+/7TG+)
(IPMI) LAN
IPMI LAN
PWR_SW1
Power Switch (Button)
(I-)SATA 0/1
SATA 3.0 Connectors 0/1 from Intel AHCI
(I-) SATA 2-5
SATA 2.0 Connectors 2/3/4/5 from Intel AHCI
(L)-SAS 0-7
SAS Connectors 0-7 from LSI 2308 SAS Controller
(X9DRFF-7G+/7TG+ Only)
6-SGPIO 1/2
Serial_Link General Purpose I/O Headers for SAS connections (X9DRFF-7G+/7TG+)
T-SGPIO 1/2
Serial_Link General Purpose I/O Headers 1/2 for Intel
SATA connections
(CPU1) Slot1
PCI-Exp. 3.0 x16 SMC-Proprietary Slot
1-5
X9DRFF-iG+/iTG+/7G+/7TG+ Motherboard User’s Manual
(CPU1) Slot2/Slot3
PCI-Exp. 3.0 x8 Slots
SXB1 (CPU2) PCI-E x32
Slot
PCI-Exp. 3.0 x32 SMC-Proprietary Slot
UID_SW1
UID (Unit Identifier) Switch (SW1)
USB0/USB1
Front Panel USB 0/ USB1 Ports
(J)USB2
Internal USB 2 Port
VGA1
Front Panel VGA Port
X9DRFF-iG+/iTG+/7G+/7TG+ LED Indicators
LED
Description
State
Status
BMC_HB_LED1
BMC Heartbeat LED
Green: Blinking
BMC Normal
HDD_ACT LED1
HDD Activity LED
Green: Blinking
HDD Active
Failure_LED1
Failure LED
On/Blinking
On: Power Failure;
Blinking: Fan Failure
LEDS2
SAS Heartbeat LED
Green
SAS Normal
UID_LED1
UID LED
Blue: On
Unit Identified
Note: To provide adequate power supply to the motherboard, be sure to
use SMC-proprietary power supply to connect 8-pin power connectors
(JPW1/JPW2), and 4-pin power connectors (JPW3). SMC-proprietary
backplanes or adaptor cards may be required to ensure adequate power
supply to your system. Refer to the server user's manual that came with
your system for instructions on power supply recommendations.
1-6
Chapter 1: Overview
Motherboard Features
CPU
• Dual Intel® E5-2600(v2) Series Processors (Socket R
LGA 2011); each processor supports four full-width
Intel QuickPath Interconnect (QPI) links (with support
of up to 25.6 GT/s per QPI link and with Data Transfer
Rate of up to 8.0 GT/s per direction).
Note: For Intel E5-2600(v2) processor support,
BIOS version 3.0 or above is required.
Memory
•Integrated memory controller supports up to 1 TB
of Load Reduced (LRDIMM), 512 GB of Registered
(RDIMM) or 128 GB of Unbuffered (UDIMM) ECC/
Non-ECC DDR3 800/1066/1333/1600/1866 MHz
240-pin 4-channel memory modules in 16 DIMM
slots.
Note 1: 1866 MHz memory speed is dependent
on Intel E5-2600v2 CPUs.
Note 2: For an updated memory support list,
please refer to the Tested Memory List on the
motherboard specification webpage.
Chipset
Expansion
Slot
• Intel® C602 Chipset
• One (1) PCI-E 3.0 x32 (SMC-Proprietary) slot (SXB1
CPU2 3.0 x32 Slot)
• One (1) PCI-E 3.0 x16 (SMC-Proprietary) slot (CPU1
Slot 1)
Graphics
Network
• Two (2) PCI-E 3.0 x8 slots (CPU1 Slot 2/Slot 3),
• One (1) PCI-E 2.0 x4 slot (PCH Slot 4)
• Nuvoton WPCM450R G200 Graphics Controller
• Intel X540 dual-channel 10G Base-T (T) Ethernet controller for LAN 1/LAN 2 ports (X9DRFFiTG+/7TG+ only),
• Intel
i350 dual-channel Gigabit (10/100/1000 Mb/s)
Ethernet controller for LAN 1/LAN 2 ports (for
X9DRFF-iG+/7G+)
• Nuvoton WPCM450R Base-Board Controller (BMC)
supports IPMI_LAN 2.0
1-7
X9DRFF-iG+/iTG+/7G+/7TG+ Motherboard User’s Manual
I/O Devices
SATA Connections
• SATA Ports
Two (2) SATA 3.0 (I-SATA 0/1),
Four (4) SATA 2.0 Ports from
Intel AHCI (I-SATA 2-5),
SAS Ports (X9DRFF-7G+/7TG+ Only)
• SAS Ports
Eight (8) SAS 2.0 Ports from
LSI 2308 SAS Controller
• RAID
RAID 0, 1, 10
Integrated IPMI 2.0
• IPMI 2.0 supported by the WPCM450R BMC
Super I/O
• Winbond Super I/O 83527HG
Peripheral
Devices
BIOS
USB Devices
• Two (2) USB ports on the front I/O panel (USB 0/1),
• One (1) Type A USB connector (JUSB 2)
• 16 MB SPI AMI BIOS® SM Flash BIOS
• APM 1.2, DMI 2.3, PCI 2.3, ACPI 1.0/2.0/3.0/4.0,
USB Keyboard, Plug & Play (PnP) and SMBIOS 2.5
Power
Config.
• ACPI/ACPM Power Management
• Main switch override mechanism
• Intel® Intelligent Power Node Manager (NM)
• Management Engine (ME)
(Note: Special power supply required. See the
note on Page 1-14)
• Keyboard Wake-up from Soft-Off
• Power-on mode for AC power recovery
PC Health
Monitoring
CPU Monitoring
• Onboard
voltage monitors for 3.3V, +3.3VSB, 5V,
+5VSB, +12V/-12V, VBAT, HT, memory voltages,
CPU core voltages, chipset voltages.
• CPU 5+1-Phase switching voltage regulator
• CPU/System overheat LED and control
• CPU Thermal Design Power (TDP): supports
130W (See Note 1 next page)
• CPU Thermal Trip support
• Thermal Monitor 2 (TM2) support
1-8
up to
Chapter 1: Overview
Fan Control
• Fan
status monitoring with firmware 4-pin (Pulse
Width Modulation) fan speed control
System
Management
Dimensions
• Low noise fan speed control
• PECI (Platform Environment Configuration Interface)
2.0 support
• System resource alert via SuperDoctor® III
• SuperDoctor® III, Watch Dog, NMI
• 18.72" (L) x 8.54" (W) (475.49 mm x 216.92 mm)
Note 1: CPU Maximum Thermal Design Power (TDP) is subject to chassis
and heatsink cooling restrictions. For proper thermal management, please
check the chassis and heatsink specifications for proper CPU TDP sizing.
Note 2: For IPMI Configuration Instructions, please refer to the Embedded
IPMI Configuration User's Guide available @ http://www.supermicro.com/
support/manuals/.
Note 3: Changing BMC log-in information is recommended during initial
system power-on. The default username is ADMIN and password is
ADMIN. For BMC best practices, please refer to: http://www.supermicro.
com/products/nfo/files/IPMI/Best_Practices_BMC_Security.pdf
1-9
Gen3 x8
LAN
X540
I350 (2 ports)
J2
P1
P1
D
P0
#1
#2
E5-2600(v2) Series Processor
PE2
PE3
Gen2 x4
DMI
#1
#2
A
AT25321
SPI
SATA
DMI
3/1.5
3/1.5
3/1.5
3/1.5
6/3/1.5
6/3/1.5
SATA2 #6
SATA2 #5
SATA2 #4
SATA2 #3
SATA3 #2
SATA3 #1
AHCI
PCH C602
USB
PEG2_0:4
Gen3 x16
PCI-32bit
Gen3 x8 (8~15)
LPC
USB
0
1
2
Type A
PEG2_5:7
Single
J4
B
CPU0
Front (I/O Side)
PE1
G
DDR3 DIMM
P0
#1
#2
Single
J3
PCI-Ex4 in x8 SLOT
J1
#1
#2
DDR3 DIMM
CPU1
Rear (Fan Side)
Gen3 x8 (0~7)
PCI-Ex8 SLOT
RJ45
PCI-Ex8 SLOT
RJ45
DDR3 DIMM
C
H
E5-2600(v2) Series Processor
#1
#2
DDR3 DIMM
#1
#2
DMI
DDR3 DIMM
PE3
DDR3 DIMM
PE2
QPI
E
PE1
F
QPI
SAS2308
#1
#2
DDR3 DIMM
#1
#2
DDR3 DIMM
SAS
Gen3 x16 x16
PCI-Ex16
Proprietary SLOT
Gen3 x8 (0~7)
DDR2
SAS2 #1
SAS2 #2
SAS2 #3
SAS2 #4
SAS2 #5
SAS2 #6
SAS2 #7
SAS2 #8
PCI-Ex16x16
Proprietary SLOT
X9DRFF-iG+/iTG+/7G+/7TG+ Motherboard User’s Manual
Gen2 x4
WPCM450
VGA BMC
VGA CONN PHY
RTL8201F
LAN
System Block Diagram
Note: This is a general block diagram and may not exactly represent the
features on your motherboard. See the Motherboard Features pages for
the actual specifications of each motherboard.
1-10
Chapter 1: Overview
1-2 Processor and Chipset Overview
Built upon the functionality and the capability of Intel E5-2600(v2) Series Processors (Socket R LGA 2011) and the C602 chipset, the X9DRFF-iG+/iTG+/7G+/7TG+
motherboard provides the performance and feature sets required for dual-processor-based 4U Fat Twin server platforms.
With support of Intel QuickPath interconnect (QPI) Technology, the X9DRFF-iG+/
iTG+/7G+/7TG+ offers point-to-point serial interconnect interface with a transfer
speed of up to 8.0 GT/s, providing superb system performance.
The C602 chipset provides extensive IO support, including the following functions
and capabilities:
•PCI-E 2.0 and 3.0 support
•ACPI Power Management Logic Support, Rev. 3.0b
•Intel® Intelligent Power Node Management (NM) (Special PS cables required)
•Management Engine (ME)
•Intel Rapid Storage Technology supported
•Intel Virtualization Technology for Directed I/O (Intel VT-d) supported
•Intel Trusted Execution Technology supported
•Serial Peripheral Interface (SPI) Supported
•Intel Anti-Theft Technology (Intel AT) supported
•Digital Media Interface (DMI) supported
•Advanced Host Controller Interface (AHCI) supported
•Compatibility Modules (DMA Controller, Timer/Counters, Interrupt Controller)
supported
Note: For Intel E5-2600(v2) processor support, BIOS version 3.0 or above
is required.
1-11
X9DRFF-iG+/iTG+/7G+/7TG+ Motherboard User’s Manual
1-3 Special Features
Recovery from AC Power Loss
The Basic I/O System (BIOS) provides a setting that determines how the system will
respond when AC power is lost and then restored to the system. You can choose for
the system to remain powered off (in which case you must press the power switch
to turn it back on), or for it to automatically return to the power-on state. See the
Advanced BIOS Setup section for this setting. The default setting is Last State.
1-4 PC Health Monitoring
This section describes the features of PC health monitoring of the motherboard.
This motherboard has an onboard System_Hardware_Monitor chip that supports
PC health monitoring. An onboard voltage monitor will scan the following onboard
voltages continuously: Onboard voltage monitors for 3.3V, +3.3VSB, 5V, +5VSB,
+12V/-12V, VBAT, HT, memory voltages, chipset voltages and CPU core voltages .
Once a voltage becomes unstable, a warning is given, or an error message is sent
to the screen. The user can adjust the voltage thresholds to define the sensitivity
of the voltage monitor.
Environmental Temperature Control
A thermal control sensor monitors the CPU temperatures in real time and will turn
on the thermal control fans whenever the CPU temperature exceeds a user-defined
threshold. The overheat circuitry runs independently from the CPU. Once it detects
that the CPU temperature is too high, it will automatically turn on the thermal fan
control to prevent the CPU from overheating. The onboard chassis thermal circuitry
can monitor the overall system temperature and alert the user when the chassis
temperature is too high.
Note: To avoid possible system overheating, please be sure to provide
adequate airflow to your system.
System Resource Alert
This feature is available when used with SuperDoctor® III in the Windows OS
environment or used with SuperDoctor II in Linux. SuperDoctor is used to notify
the user of certain system events. For example, you can configure SuperDoctor
to provide you with warnings when the system temperature, CPU temperatures,
voltages, and fan speeds go beyond a predefined range.
1-12
Chapter 1: Overview
1-5 ACPI Features
ACPI stands for Advanced Configuration and Power Interface. The ACPI specification defines a flexible and abstract hardware interface that provides a standard
way to integrate power management features throughout a PC system, including
its hardware, operating system and application software. This enables the system
to automatically turn on and off peripherals such as CD-ROMs, network cards, hard
disk drives and printers.
In addition to operating_system-directed power management, ACPI also provides
a generic system event mechanism for Plug and Play, and an operating systemindependent interface for configuration control. ACPI leverages the Plug and
Play BIOS data structures while providing a processor_architecture-independent
implementation that is compatible with Windows 7, Windows 8, and Windows 2008
Operating Systems.
Slow Blinking LED for Suspend-State Indicator
When the CPU goes into a suspend state, the chassis power LED will start blinking
to indicate that the CPU is in the suspend mode. When the user presses any key,
the CPU will "wake up," and the LED will automatically stop blinking and remain on.
1-6 Power Supply
As with all computer products, a stable power source is necessary for proper and
reliable operation. It is even more important for processors that have high CPU
clock rates.
The X9DRFF-iG+/iTG+/7G+/7TG+ motherboard supports two 8-pin and one 4-pin
power supplies. Although most power supplies generally meet the specifications
required by the CPU, some are inadequate. All these power connections are required for Fat Twin use only.
Note: To ensure adequate power to the system, SMC-proprietary power
backplanes or adaptors may be required. Refer to the server user's manual
that came with your system for detailed instructions on power supply
recommendations.
1-13
X9DRFF-iG+/iTG+/7G+/7TG+ Motherboard User’s Manual
1-7 Super I/O
The Super I/O provides functions that comply with ACPI (Advanced Configuration
and Power Interface), which includes support of legacy and ACPI power management through an SMI or SCI function pin. It also features auto power management
to reduce power consumption.
Note 1: For more information on IPMI configuration, please refer to the
IPMI User's Guide posted on our website at http://www.supermicro.com/
support/manuals/.
Note 2: The term "IPMI controller" and the term "BMC controller" can be
used interchangeably in this section.
1-8 Advanced Power Management
The new advanced power management features supported by this motherboard
include IPNM and ME. Please note that you will need to do the following to use
these two new features:
•Use a power supply that supports PMBus 1.1 or 1.2.
•Install the NMView software in your system. NMView is optional and can be
purchased from Supermicro.
Intel® Intelligent Power Node Manager (IPNM)
The Intel® Intelligent Power Node Manager (IPNM) provides your system with
real-time thermal control and power management for maximum energy efficiency.
Although IPNM is supported by the BMC (Baseboard Management Controller),
your system must also have IPNM-compatible Management Engine (ME) firmware
installed in your system for IPNM support.
Note: Support for IPNM Specification Version 1.5 or Vision 2.0 depends
on the power supply used in the system.
Management Engine (ME)
The Management Engine, which is an ARC controller embedded in the PCH, provides Server Platform Services (SPS) to your system. The services provided by
SPS are different from those provided by the ME on client platforms.
1-14
Chapter 1: Overview
1-9 Overview of the Nuvoton WPCM450 Controller
Note: The term "IPMI controller" and the term "BMC controller" can be
used interchangeably in this section.
The Nuvoton WPCM450R Controller, a Baseboard Management Controller (BMC),
supports 2D/VGA-compatible Graphic Cores with PCI interface, creating multi-media
virtualization via Keyboard/Video/Mouse Redirection (KVMR). The WPCM450R
Controller is ideal for remote system management.
The WPCM450R Controller interfaces with the host system via PCI connections
to communicate with the graphics cores. It supports USB 2.0 and 1.1 for remote
keyboard/mouse/virtual media emulation. It also provides LPC interface support to
control Super IO functions. The WPCM450R Controller is connected to the network
via an external Ethernet PHY module or shared NCSI connections.
The WPCM450R communicates with onboard components via six SMBus interfaces, PECI (Platform Environment Control Interface) buses, and General Purpose
I/O ports.
WPCM450R DDR2 Memory Interface
The WPCM450R supports a 16-bit DDR2 memory module with a speed of up to 220
MHz. For best signal integrity, the WPCM450R provides point-to-point connection.
WPCM450R PCI System Interface
The WPCM450R provides 32-bit, 33 MHz 3.3V PCI interface, which is compliant
with the PCI Local Bus Specification Rev. 2.3. The PCI system interface connects
to the onboard PCI Bridge used by the graphics controller.
Other Features Supported by the WPCM BMC Controller
The WPCM450R supports the following features:
•IPMI 2.0
•Serial over LAN
•KVM over LAN
•LAN Alerting-SNMP Trap
•Event Log
•X-Bus parallel interface for I/O expansion
1-15
X9DRFF-iG+/iTG+/7G+/7TG+ Motherboard User’s Manual
•Multiple ADC inputs, Analog and Digital Video outputs
•SPI Flash Host BIOS and firmware bootstrap program supported
•Reduced Media Independent Interface (RMII)
•OS (Operating System) Independency
•Provides remote Hardware Health Monitoring via IPMI. Key features
•Provides Network Management Security via remote access/console redirection.
•Supports
the following Management tools: IPMIView, CLI (Command Line
Interface)
•RMCP+ protocol supported
Note 1: For more information on IPMI configuration, please refer to the
IPMI User's Guide posted on our website at http://www.supermicro.com/
support/manuals/.
Note 2: The term "IPMI controller" and the term "BMC controller" can be
used interchangeably in this section.
1-16
Chapter 2: Installation
Chapter 2
Installation
2-1 Standardized Warning Statements
The following statements are industry-standard warnings, provided to warn the user
of situations which have the potential for bodily injury. Should you have questions or
experience difficulty, contact Supermicro's Technical Support department for assistance. Only certified technicians should attempt to install or configure components.
Read this section in its entirety before installing or configuring components in the
Supermicro chassis.
Battery Handling
Warning!
There is a danger of explosion if the battery is replaced incorrectly. Replace the
battery only with the same or equivalent type recommended by the manufacturer.
Dispose of used batteries according to the manufacturer's instructions
電池の取り扱い
電池交換が正しく行われなかった場合、破裂の危険性があります。交換する電池はメー
カーが推奨する型、
または同等のものを使用下さい。使用済電池は製造元の指示に従
って処分して下さい。
警告
电池更换不当会有爆炸危险。请只使用同类电池或制造商推荐的功能相当的电池更
换原有电池。请按制造商的说明处理废旧电池。
警告
電池更換不當會有爆炸危險。請使用製造商建議之相同或功能相當的電池更換原有
電池。請按照製造商的說明指示處理廢棄舊電池。
Warnung
Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr. Ersetzen Sie die
Batterie nur durch den gleichen oder vom Hersteller empfohlenen Batterietyp.
Entsorgen Sie die benutzten Batterien nach den Anweisungen des Herstellers.
2-1
X9DRFF-iG+/iTG+/7G+/7TG+ Motherboard User’s Manual
Attention
Danger d'explosion si la pile n'est pas remplacée correctement. Ne la remplacer
que par une pile de type semblable ou équivalent, recommandée par le fabricant.
Jeter les piles usagées conformément aux instructions du fabricant.
¡Advertencia!
Existe peligro de explosión si la batería se reemplaza de manera incorrecta. Reemplazar la batería exclusivamente con el mismo tipo o el equivalente recomendado por el fabricante. Desechar las baterías gastadas según las instrucciones
del fabricante.
!‫אזהרה‬
‫ יש להחליף‬.‫קיימת סכנת פיצוץ של הסוללה במידה והוחלפה בדרך לא תקינה‬
.‫את הסוללה בסוג התואם מחברת יצרן מומלצת‬
.‫סילוק הסוללות המשומשות יש לבצע לפי הוראות היצרן‬
‫هناك خطر من انفجار في حالة اسحبذال البطارية بطريقة غير صحيحة فعليل‬
‫اسحبذال البطارية‬
‫فقط بنفس النىع أو ما يعادلها مما أوصث به الشرمة المصنعة‬
‫جخلص من البطاريات المسحعملة وفقا لحعليمات الشرمة الصانعة‬
경고!
배터리가 올바르게 교체되지 않으면 폭발의 위험이 있습니다. 기존 배터리와 동일
하거나 제조사에서 권장하는 동등한 종류의 배터리로만 교체해야 합니다. 제조사
의 안내에 따라 사용된 배터리를 처리하여 주십시오.
Waarschuwing
Er is ontploffingsgevaar indien de batterij verkeerd vervangen wordt. Vervang de
batterij slechts met hetzelfde of een equivalent type die door de fabrikant aanbevolen wordt. Gebruikte batterijen dienen overeenkomstig fabrieksvoorschriften
afgevoerd te worden.
2-2
Chapter 2: Installation
Product Disposal
Warning!
Ultimate disposal of this product should be handled according to all national laws
and regulations.
製品の廃棄
この製品を廃棄処分する場合、国の関係する全ての法律・条例に従い処理する必要が
あります。
警告
本产品的废弃处理应根据所有国家的法律和规章进行。
警告
本產品的廢棄處理應根據所有國家的法律和規章進行。
Warnung
Die Entsorgung dieses Produkts sollte gemäß allen Bestimmungen und Gesetzen
des Landes erfolgen.
¡Advertencia!
Al deshacerse por completo de este producto debe seguir todas las leyes y reglamentos nacionales.
Attention
La mise au rebut ou le recyclage de ce produit sont généralement soumis à des
lois et/ou directives de respect de l'environnement. Renseignez-vous auprès de
l'organisme compétent.
‫סילוק המוצר‬
!‫אזהרה‬
.‫סילוק סופי של מוצר זה חייב להיות בהתאם להנחיות וחוקי המדינה‬
2-3
X9DRFF-iG+/iTG+/7G+/7TG+ Motherboard User’s Manual
‫عند التخلص النهائي من هذا المنتج ينبغي التعامل معه وفقا لجميع القىانين واللىائح الىطنية‬
경고!
이 제품은 해당 국가의 관련 법규 및 규정에 따라 폐기되어야 합니다.
Waarschuwing
De uiteindelijke verwijdering van dit product dient te geschieden in overeenstemming
met alle nationale wetten en reglementen.
2-2 Static-Sensitive Devices
Electrostatic Discharge (ESD) can damage electronic com­ponents. To avoid damaging your system board, it is important to handle it very carefully. The following
measures are generally sufficient to protect your equipment from ESD.
Precautions
•Use a grounded wrist strap designed to prevent static discharge.
•Touch a grounded metal object before removing the board from the antistatic
bag.
•Handle the board by its edges only; do not touch its components, peripheral
chips, memory modules or gold contacts.
•When handling chips or modules, avoid touching their pins.
•Put the motherboard and peripherals back into their antistatic bags when not
in use.
•For grounding purposes, make sure that your system chassis provides excellent
conductivity between the power supply, the case, the mounting fasteners and
the motherboard.
Unpacking
The motherboard is shipped in antistatic packaging to avoid static damage. When
unpacking the board, make sure that the person handling it is static protected.
2-4
Chapter 2: Installation
2-3 Processor and Heatsink Installation
Warning: When handling the processor package, avoid placing direct pressure on
the label area.
Notes:
•Always connect the power cord last, and always remove it before adding,
removing or changing any hardware components. Make sure that you install
the processor into the CPU socket before you install the CPU heatsink.
•If you buy a CPU separately, make sure that you use an Intel-certified multidirectional heatsink only.
•Make sure to install the system board into the chassis before you install
the CPU heatsink.
•When receiving a server board without a processor pre-installed, make sure
that the plastic CPU socket cap is in place and none of the socket pins are
bent; otherwise, contact your retailer immediately.
•Refer to the Supermicro website for updates on CPU support.
Installing the LGA2011 Processor
1. There are two load levers on the LGA2011 socket. To open the socket cover,
first press and release the load lever labeled 'Open 1st'.
2
1
WA
R
NI
OP
EN
NG
WA
R
NI
!
OP
EN
1st
Press down
on Load Lever
labeled 'Open 1st'.
2-5
1st
NG
!
X9DRFF-iG+/iTG+/7G+/7TG+ Motherboard User’s Manual
2. Press the second load lever labeled 'Close 1st' to release the load plate that
covers the CPU socket from its locking position.
1
Press down on Load the
Lever labeled 'Close 1st'
NI
OP
EN
Pull lever away from
the socket
WA
R
WA
R
Pin 1
2
NG
NI
NG
!
OP
EN
1st
!
1st
3. With the lever labeled 'Close 1st' fully retracted, gently push down on the
'Open 1st' lever to open the load plate. Lift the load plate to open it completely.
Gently push
down to pop the
load plate open.
1
WA
R
NI
OP
EN
NG
2
!
1st
WA
R
NI
2-6
NG
!
Chapter 2: Installation
1. Using your thumb and the index finger, remove the 'WARNING' plastic cap
from the socket.
WA
R
NIN
G!
2. Use your thumb and index finger to hold the CPU on its edges. Align the CPU
keys, which are semi-circle cutouts, against the socket keys.
Socket Keys
CPU Keys
3. Once they are aligned, carefully lower the CPU straight down into the socket.
(Do not drop the CPU on the socket. Do not move the CPU horizontally or
vertically. Do not rub the CPU against the surface or against any pins of the
socket to avoid damaging the CPU or the socket.)
Warning: You can only install the CPU
inside the socket in one direction.
Make sure that it is properly inserted
into the CPU socket before closing the
load plate. If it doesn't close properly,
do not force it as it may damage your
CPU. Instead, open the load plate
again and double-check that the CPU
is aligned properly.
2-7
X9DRFF-iG+/iTG+/7G+/7TG+ Motherboard User’s Manual
4. With the CPU inside the socket, inspect the four corners of the CPU to make
sure that the CPU is properly installed.
5. Close the load plate with the CPU inside the socket. Lock the lever labeled
'Close 1st' first, then lock the lever labeled 'Open 1st' second. Use your
thumb to gently push the load levers down to the lever locks.
1
2
Push down and lock the
level labeled 'Close 1st'.
Gently close
the load plate.
OP
EN
1st
4
3
Lever Lock
Push down and
lock the lever
labeled 'Open 1st'
OP
EN
OP
EN
1st
1st
Lever Lock
2-8
Chapter 2: Installation
Installing a Passive CPU Heatsink
1. Do not apply any thermal grease to the heatsink or the CPU die -- the required amount has already been applied.
2. Place the heatsink on top of the CPU so that the four mounting holes are
aligned with those on the Motherboard's and the Heatsink Bracket underneath.
3. Screw in two diagonal screws (i.e., the #1 and the #2 screws) until just snug
(-do not over-tighten the screws to avoid possible damage to the CPU.)
4. Finish the installation by fully tightening all four screws.
Screw#1
Screw#3
Screw#4
Direction of Airflow
Screw#2
Motherboard
OP
EN
1s
Mounting Holes
t
Notes: 1. For optimized airflow, please follow your chassis airflow direction
to install the correct CPU heatsink direction. 2. Graphic drawings included
in this manual are for reference only. They might look different from the
components installed in your system.
2-9
X9DRFF-iG+/iTG+/7G+/7TG+ Motherboard User’s Manual
Removing the Heatsink
Warning: We do not recommend that the CPU or the heatsink be removed. However,
if you do need to uninstall the heatsink, please follow the instructions below to avoid
damaging the CPU or the CPU socket.
1. Unscrew the heatsink screws from the motherboard in the sequence as
shown in the illustration below.
2. Gently wriggle the heatsink to loosen it from the CPU. (Do not use excessive
force when wriggling the heatsink!)
3. Once the CPU is loosened from the heatsink, remove the CPU from the CPU
socket.
4. Remove the used thermal grease and clean the surface of the CPU and the
heatsink, Reapply the proper amount of thermal grease on the surface before
reinstalling the CPU and the heatsink.
Loosen screws
in sequence as
shown.
Screw#1
Screw#3
Screw#4
Direction of Airflow
Screw#2
Motherboard
OP
EN
1s
t
2-10
Chapter 2: Installation
2-4 Installing and Removing the Memory Modules
Note: Check Supermicro's Website for recommended memory modules.
CAUTION
Exercise extreme care when installing or removing DIMM
modules to prevent any possible damage.
Installing & Removing DIMMs
1. Insert the desired number of DIMMs into the memory slots, starting with
P1-DIMMA1. (For best performance, please use the memory modules of the
same type and speed in the same bank.)
2. Push the release tabs outwards on both ends of the DIMM slot to unlock it.
VGA1
JPG1
JPB1
USB1
LAN2
IPMI CODE
MAC CODE
MEGERAC LICENSE
Intel PCH
SAS CODE
LEDS2
JBT1
JPS1
X9DRFF-iG+
Notches
IPMI_ LAN
LAN1
HDD_ACT_LED1
CPLD1
BIOS
PCH SLOT4 PCIE-E 2.0X4
BMC_HB_LED1
JP6
JBR1
JIPMB1 JPI2C1
CPU1 SLOT3 PCI-E 3.0X8
JP7
1
LSI SAS
CTRL
Rev. 1.01
JBAT1
JSD1
P1-DIMMA1
P1-DIMMA2
6-SGPIO2
6-SGPIO1
T-SGPIO2
T-SGPIO1
P1-DIMMB1
I-SATA5 L-SAS6 L-SAS7
I-SATA4 L-SAS4 L-SAS5
I-SATA3 L-SAS2 L-SAS3
I-SATA2 L-SAS0 L-SAS1
I-SATA0 I-SATA1
P1-DIMMD2
P1-DIMMD1
HDD_PWR2
P1-DIMMB2
P1-DIMMC1
P1-DIMMC2
CPU1 SLOT2 PCI-E 3.0X8
CPU1 SLOT1 PCI-E X16 PROPRIETARY SLOT
JWD1
JI2C2
JI2C1
USB2
BMC
USB0
PWR_SW1
UID_SW1
UID_LED1
FAILURE_LED1
JPL1
Intel LAN
CTRL
JPME1
JPME2
CPU1
CLOSE 1st
OPEN 1st
P2-DIMME2
P2-DIMMF1
P2-DIMMF2
P2-DIMME1
P2-DIMMH1
P2-DIMMG2
P2-DIMMG1
P2-DIMMH2
SXB1:CPU2 PCI-E X32
PROPRIENTAR SLOT
JPW3
Release Tabs
CPU2
Rear_FAN
PS_ON_N
JPW2
CLOSE 1st
OPEN 1st
FAN3
FAN4
FAN2
FAN5
FAN6
FAN1
FAN8
FAN7
HDD
JPW1 PWR1
3. Align the key of the DIMM module with the receptive point on the DIMM slot.
4. Align the notches on both ends of the module against the receptive points on
the ends of the slot.
5. Use two thumbs together to press the notches on both ends of the module
straight down into the slot until the module snaps into place.
6. Press the release tabs to the locking positions to secure the DIMM module
into the slot.
Press both notches straight
down into the memory slot at
the same time.
Removing Memory Modules
Press both notches at the ends of a DIMM module to unlock it. Once it is loosened
from the memory slot, remove the DIMM module from the motherboard.
2-11
X9DRFF-iG+/iTG+/7G+/7TG+ Motherboard User’s Manual
Memory Support for the X9DRFF-iG+/iTG+/7G+/7TG+
Motherboard
The X9DRFF-iG+/iTG+/7G+/7TG+ motherboard supports up to 1 TB of Load
Reduced (LRDIMM), 512 GB of Registered (RDIMM) or 128 GB of Unbuffered
(UDIMM) ECC/Non-ECC DDR3 800/1066/1333/1600/1866 MHz 240-pin 4-channel memory modules in 16 DIMM slots. Please refer to our website at http://www.
supermicro.com/products/motherboard.
Processor & Memory Module Population Configuration
For memory to work properly, follow the tables below for memory installation.
Processors and their Corresponding Memory Modules
CPU#
Corresponding DIMM Modules
CPU 1
P1DIMMA1
P1DIMMB1
P1DIMMC1
P1DIMMD1
P1DIMMA2
P1DIMMB2
P1DIMMC2
P1DIMMD2
CPU2
P2DIMME1
P2DIMMF1
P2DIMMG1
P2DIMMH1
P2DIMME2
P2DIMM F2
P2DIMMG2
P2DIMMH2
Processor and Memory Module Population for Optimal Performance
Number of
CPUs+DIMMs
CPU and Memory Population Configuration Table
(For memory to work properly, please follow the instructions below.)
1 CPU &
2 DIMMs
CPU1
P1-DIMMA1/P1-DIMMB1
1 CPU &
4 DIMMs
CPU1
P1-DIMMA1/P1-DIMMB1, P1-DIMMC1/P1-DIMMD1
1 CPU &
5~8 DIMMs
CPU1
P1-DIMMA1/P1-DIMMB1, P1-DIMMC1/P1-DIMMD1 + Any memory pairs in P1DIMMA2/P1-DIMMB2/P1-DIMMC2/P1-DIMMD2 slots
2 CPUs &
4 DIMMs
CPU1 + CPU2
P1-DIMMA1/P1-DIMMB1, P2-DIMME1/P2-DIMMF1
2 CPUs &
6 DIMMs
CPU1 + CPU2
P1-DIMMA1/P1-DIMMB1/P1-DIMMC1/P1-DIMMD1, P2-DIMME1/P2-DIMMF1
2 CPUs &
8 DIMMs
CPU1 + CPU2
P1-DIMMA1/P1-DIMMB1/P1-DIMMC1/P1-DIMMD1, P2-DIMME1/P2-DIMMF1/P2DIMMG1/P2-DIMMH1
2 CPUs &
10~16 DIMMs
CPU1/CPU2
P1-DIMMA1/P1-DIMMB1/P1-DIMMC1/P1-DIMMD1, P2-DIMME1/P2-DIMMF1/P2DIMMG1/P2-DIMMH1 + Any memory pairs in P1, P2 DIMM slots
2 CPUs &
16 DIMMs
CPU1/CPU2
P1-DIMMA1/P1-DIMMB1/P1-DIMMC1/P1-DIMMD1, P2-DIMME1/P2-DIMMF1/P2-DIMMG1/P2-DIMMH1,P1-DIMMA2/P1-DIMMB2/P1-DIMMC2/P1-DIMMD2, P2-DIMME2/
P2-DIMMF2/P2-DIMMG2/P2-DIMMH2
Notes: 1866 MHz memory speed is dependent on Intel E5-2600v2 CPUs.
For Intel E5-2600(v2) processor support, BIOS version 3.0 or above is
required.
2-12
Chapter 2: Installation
Populating UDIMM (ECC/Non-ECC) Memory Modules
Intel E5-2600(v2) Series Processor UDIMM Memory Support
Ranks
Per
DIMM
& Data
Width
Memory Capacity
Per DIMM
Speed (MT/s) and Voltage Validated by Slot per Channel (SPC) and
DIMM Per Channel (DPC)
2 Slots Per Channel
(See the Note below)
1DPC
3 Slots Per Channel
2DPC
1DPC
2DPC
1.35V
1.5V
1.35V
1.5V
1.35V
1.5V
1.35V
1.5v
SRx8
NonECC
1GB
2GB
4GB
NA
1066,
1333,
1600,
1866
NA
1066,
1333,
1600
N/A
1066,
1333,
1600,
1866
N/A
1066,
1333,
1600
DRx8
NonECC
2GB
4GB
8GB
NA
1066,
1333,
1600,
1866
NA
1066,
1333,
1600
N/A
1066,
1333,
1600,
1866
N/A
1066,
1333,
1600
SRx16
NonECC
512MB
1GB
2GB
NA
1066,
1333,
1600,
1866
NA
1066,
1333,
1600
N/A
1066,
1333,
1600,
1866
N/A
1066,
1333,
1600
SRx8
ECC
1GB
2GB
4GB
1066,
1333
1066,
1333,
1600,
1866
1066,
1333
1066,
1333,
1600
1066,
1333
1066,
1333,
1600,
1866
1066,
1333
1066,
1333,
1600
DRx8
ECC
2GB
4GB
8GB
1066,
1333
1066,
1333,
1600,
1866
1066,
1333
1066,
1333,
1600
1066,
1333
1066,
1333,
1600,
1866
1066,
1333
1066,
1333,
1600
Note: For detailed information on memory support and updates, please refer to the SMC Recommended
Memory List posted on our website at http://www.supermicro.com/support/resources/mem.cfm.
Populating RDIMM (ECC) Memory Modules
Intel E5-2600(v2) Series Processor RDIMM Memory Support
Ranks
Per
DIMM
&
Data
Width
Memory Capacity
Per DIMM
Speed (MT/s) and Voltage Validated by Slot per Channel (SPC) and DIMM Per Channel
(DPC)
2 Slots Per Channel
(See the Note Below)
1DPC
3 Slots Per Channel
2DPC
1 DPC
2DPC
3DPC
1.35V
1.5V
1.35V
1.5V
1.35V
1.5V
1.35V
1.5V
1.35V
1.5v
SRx8
1GB
2GB
4GB
1066,
1333
1066,
1333,
1600,
1866
1066,
1333
1066,
1333,
1600
1066,
1333
1066,
1333,
1600,
1866
1066,
1333
1066,
1333,
1600
800
800,
1066
DRx8
2GB
4GB
8GB
1066,
1333
1066,
1333,
1600,
1866
1066,
1333
1066,
1333,
1600
1066,
1333
1066,
1333,
1600,
1866
1066,
1333
1066,
1333,
1600
800
800,
1066
SRx4
2GB
4GB
8GB
1066,
1333
1066,
1333,
1600,
1866
1066,
1333
1066,
1333,
1600
1066,
1333
1066,
1333,
1600,
1866
1066,
1333
1066,
1333,
1600
800
800,
1066
DRx4
4GB
8GB
16GB
1066,
1333
1066,
1333,
1600,
1866
1066,
1333
1066,
1333,
1600
1066,
1333
1066,
1333,
1600,
1866
1066,
1333
1066,
1333,
1600
800
800,
1066
QRx4
8GB
16GB
32GB
800
800
1066
800
800
800
800,
1066
800
800
N/A
N/A
QRx8
4GB
8GB
16GB
800
800
1066
800
800
800
800,
1066
800
800
N/A
N/A
Note: For detailed information on memory support and updates, please refer to the SMC Recommended Memory List posted on
our website at http://www.supermicro.com/support/resources/mem.cfm.
2-13
X9DRFF-iG+/iTG+/7G+/7TG+ Motherboard User’s Manual
Populating UDIMM (ECC/Non-ECC) Memory Modules
Intel E5-2600 Series Processor UDIMM Memory Support
Ranks
Per
DIMM
& Data
Width
Memory Capacity
Per DIMM
Speed (MT/s) and Voltage Validated by Slot per Channel (SPC) and
DIMM Per Channel (DPC)
2 Slots Per Channel
(See the Note below)
1DPC
3 Slots Per Channel
2DPC
1DPC
2DPC
1.35V
1.5V
1.35V
1.5V
1.35V
1.5V
1.35V
1.5v
SRx8
NonECC
1GB
2GB
4GB
NA
1066,
1333
NA
1066,
1333
N/A
1066,
1333,
N/A
1066,
1333
DRx8
NonECC
2GB
4GB
8GB
NA
1066,
1333
NA
1066,
1333
N/A
1066,
1333,
N/A
1066,
1333
SRx16
NonECC
512MB
1GB
2GB
NA
1066,
1333
NA
1066,
1333
N/A
1066,
1333
N/A
1066,
1333
SRx8
ECC
1GB
2GB
4GB
1066,
1333
1066,
1333
1066
1066,
1333
1066
1066,
1333,
1066,
1333
1066,
1333
DRx8
ECC
2GB
4GB
8GB
1066,
1333
1066,
1333
1066
1066,
1333
1066
1066,
1333,
1066,
1333
1066,
1333
Note: For detailed information on memory support and updates, please refer to the SMC Recommended
Memory List posted on our website at http://www.supermicro.com/support/resources/mem.cfm.
Populating RDIMM (ECC) Memory Modules
Intel E5-2600 Series Processor RDIMM Memory Support
Ranks
Per
DIMM
&
Data
Width
Memory Capacity
Per DIMM
Speed (MT/s) and Voltage Validated by Slot per Channel (SPC) and DIMM Per Channel
(DPC)
2 Slots Per Channel
(See the Note Below)
1DPC
3 Slots Per Channel
2DPC
1 DPC
2DPC
3DPC
1.35V
1.5V
1.35V
1.5V
1.35V
1.5V
1.35V
1.5V
1.35V
1.5v
SRx8
1GB
2GB
4GB
1066,
1333
1066,
1333,
1600
1066,
1333
1066,
1333,
1600
1066,
1333
1066,
1333,
1600
1066,
1333
1066,
1333,
1600
N/A
800,
1066
DRx8
2GB
4GB
8GB
1066,
1333
1066,
1333,
1600
1066,
1333
1066,
1333,
1600
1066,
1333
1066,
1333,
1600
1066,
1333
1066,
1333,
1600
N/A
800,
1066
SRx4
2GB
4GB
8GB
1066,
1333
1066,
1333,
1600
1066,
1333
1066,
1333,
1600
1066,
1333
1066,
1333,
1600
1066,
1333
1066,
1333,
1600
N/A
800,
1066
DRx4
4GB
8GB
16GB
1066,
1333
1066,
1333,
1600
1066,
1333
1066,
1333,
1600
1066,
1333
1066,
1333,
1600
1066,
1333
1066,
1333,
1600
N/A
800,
1066
QRx4
8GB
16GB
32GB
800
1066
800
800
800
1066
800
800
N/A
N/A
QRx8
4GB
8GB
16GB
800
1066
800
800
800
1066
800
800
N/A
N/A
Note: For detailed information on memory support and updates, please refer to the SMC Recommended Memory List posted on
our website at http://www.supermicro.com/support/resources/mem.cfm.
2-14
Chapter 2: Installation
Populating LRDIMM (ECC) Memory Modules
Intel E5-2600(v2) Series Processor LRDIMM Memory Support
Ranks
Per
DIMM
&
Data
Width
Memory
Capacity
Per DIMM
(See the Note
Below)
Speed (MT/s) and Voltage Validated by Slot per Channel (SPC) and DIMM Per
Channel (DPC)
2 Slots Per Channel
1DPC
1.35V
1.5V
1.35V
1066,
1333,
1600
QRx4
(DDP)
16GB
32GB
1066,
1333,
1600
1066,
1333,
1600,
1866
8Rx4
(QDP)
32GB
64GB
1066
1066
3 Slots Per Channel
2DPC
1066
1DPC
2DPC
3DPC
1.5V
1.35V
1.5V
1.35V
1.5V
1.35V
1.5V
1066,
1333,
1600
1066,
1333,
1600
1066,
1333,
1600,
1866
1066,
1333,
1600
1066,
1333,
1600
1066
1066
1066
1066
1066
1066
1066
1066
1066
Note: For detailed information on memory support and updates, please refer to the SMC Recommended Memory
List posted on our website at http://www.supermicro.com/support/resources/mem.cfm.
Intel E5-2600 Series Processor LRDIMM Memory Support
Ranks
Per
DIMM
&
Data
Width
Memory
Capacity
Per DIMM
(See the Note
Below)
Speed (MT/s) and Voltage Validated by Slot per Channel (SPC) and DIMM Per
Channel (DPC)
2 Slots Per Channel
1DPC
2DPC
1.35V
1.5V
1.35V
1066
QRx4
(DDP)
16GB
32GB
1066
1066,
1333
QRx8
(QDP)
8GB
16GB
1066
1066,
1333
3 Slots Per Channel
1066
1DPC
2DPC
3DPC
1.5V
1.35V
1.5V
1.35V
1.5V
1.35V
1.5V
1066,
1333
1066
1066,
1333
1066
1066,
1333
1066
1066
1066,
1333
1066
1066
1066
1066
1066
1066
Note: For detailed information on memory support and updates, please refer to the SMC Recommended Memory
List posted on our website at http://www.supermicro.com/support/resources/mem.cfm.
Other Important Notes and Restrictions
•For the memory modules to work properly, please install DIMM modules of the same
type, same speed and same operating frequency on the motherboard. Mixing of
RDIMMs, UDIMMs or LRDIMMs is not allowed. Do not install both ECC and Non-ECC
memory modules on the same motherboard.
•Using DDR3 DIMMs with different operating frequencies is not allowed. All channels
in a system will run at the lowest common frequency.
2-15
X9DRFF-iG+/iTG+/7G+/7TG+ Motherboard User’s Manual
2-5 Motherboard Installation
All motherboards have standard mounting holes to fit different types of chassis.
Make sure that the locations of all the mounting holes for both motherboard and
chassis match. Although a chassis may have both plastic and metal mounting fasteners, metal ones are highly recommended because they ground the motherboard
to the chassis. Make sure that the metal standoffs click in or are screwed in tightly.
Then use a screwdriver to secure the motherboard onto the motherboard tray.
Tools Needed
•Phillips Screwdriver
•Pan head screws (10 pieces)
•Standoffs (10 pieces, if needed)
Location of Mounting Holes
There are ten (10) mounting holes on this motherboard indicated by the arrows.
JPG1
JPB1
JPME1
USB1
LAN2
HDD_ACT_LED1
IPMI CODE
MAC CODE
CPLD1
BIOS
MEGERAC LICENSE
Intel PCH
SAS CODE
LEDS2
JBT1
JPS1
X9DRFF-iG+
PCH SLOT4 PCIE-E 2.0X4
BMC_HB_LED1
CPU1 SLOT3 PCI-E 3.0X8
JP6
JBR1
JIPMB1 JPI2C1
LSI SAS
CTRL
Rev. 1.01
JBAT1
JSD1
P1-DIMMA1
P1-DIMMA2
6-SGPIO2
6-SGPIO1
T-SGPIO2
T-SGPIO1
P1-DIMMB2
P1-DIMMB1
I-SATA5 L-SAS6 L-SAS7
I-SATA4 L-SAS4 L-SAS5
I-SATA3 L-SAS2 L-SAS3
I-SATA2 L-SAS0 L-SAS1
I-SATA0 I-SATA1
P1-DIMMD2
P1-DIMMD1
HDD_PWR2
P1-DIMMC1
P1-DIMMC2
CPU1 SLOT2 PCI-E 3.0X8
CPU1 SLOT1 PCI-E X16 PROPRIETARY SLOT
JP7
1
BMC
IPMI_ LAN
LAN1
JPME2
JWD1
JI2C2
JI2C1
USB2
USB0
PWR_SW1
UID_SW1
UID_LED1
FAILURE_LED1
JPL1
Intel LAN
CTRL
VGA1
CPU1
CLOSE 1st
OPEN 1st
P2-DIMME2
P2-DIMMF1
P2-DIMMF2
P2-DIMME1
P2-DIMMH1
P2-DIMMG2
P2-DIMMH2
P2-DIMMG1
SXB1:CPU2 PCI-E X32
PROPRIENTAR SLOT
Note: Only one
standoff is needed.
Refer to your
chassis for the
standoff location.
JPW3
CPU2
Rear_FAN
PS_ON_N
JPW2
CLOSE 1st
OPEN 1st
FAN2
FAN3
FAN4
FAN5
FAN6
FAN1
FAN8
FAN7
HDD
JPW1 PWR1
Caution: 1) To avoid damaging the motherboard and its components, please do
not use a force greater than 8 lb/inch on each mounting screw during motherboard
installation. 2) Some components are very close to the mounting holes. Please take
precautionary measures to prevent damage to these components when installing the
motherboard to the chassis.
2-16
Chapter 2: Installation
Installing the Motherboard
1. Install the I/O shield into the chassis.
2. Locate the mounting holes on the motherboard.
3. Locate the matching mounting holes on the chassis. Align the mounting holes
on the motherboard against the mounting holes on the chassis.
4. Install standoffs in the chassis as needed.
5. Install the motherboard into the chassis carefully to avoid damaging motherboard components.
6. Using the Phillips screwdriver, insert a Pan head #6 screw into a mounting
hole on the motherboard and its matching mounting hole on the chassis.
7. Repeat Step 5 to insert #6 screws into all mounting holes.
8. Make sure that the motherboard is securely placed in the chassis.
Note: Images displayed are is for illustration only. Your chassis or components might look different from those shown in this manual.
2-17
X9DRFF-iG+/iTG+/7G+/7TG+ Motherboard User’s Manual
2-6 Control Panel Connectors and I/O Ports
The I/O ports are color coded in conformance with the PC 99 specification. See
the picture below for the colors and locations of the various I/O ports.
Front Panel Connectors and I/O Ports
USB1
JPG1
JPB1
JPME1
VGA1
LAN2
IPMI CODE
MAC CODE
MEGERAC LICENSE
Intel PCH
SAS CODE
LEDS2
JBT1
JPS1
X9DRFF-iG+
HDD_ACT_LED1
CPLD1
BIOS
PCH SLOT4 PCIE-E 2.0X4
BMC_HB_LED1
CPU1 SLOT3 PCI-E 3.0X8
JP6
JBR1
JIPMB1 JPI2C1
LSI SAS
CTRL
Rev. 1.01
JBAT1
3
4
5
I-SATA5 L-SAS6 L-SAS7
I-SATA4 L-SAS4 L-SAS5
I-SATA3 L-SAS2 L-SAS3
I-SATA2 L-SAS0 L-SAS1
I-SATA0 I-SATA1
CPU1
CLOSE 1st
1 2
JSD1
P1-DIMMA1
6-SGPIO2
6-SGPIO1
T-SGPIO2
T-SGPIO1
P1-DIMMB2
P1-DIMMB1
P1-DIMMA2
P1-DIMMD2
P1-DIMMD1
HDD_PWR2
P1-DIMMC1
P1-DIMMC2
CPU1 SLOT2 PCI-E 3.0X8
CPU1 SLOT1 PCI-E X16 PROPRIETARY SLOT
JP7
1
BMC
IPMI_ LAN
LAN1
JPME2
JWD1
JI2C2
JI2C1
USB2
USB0
PWR_SW1
UID_SW1
UID_LED1
FAILURE_LED1
JPL1
Intel LAN
CTRL
OPEN 1st
P2-DIMME2
P2-DIMMF2
P2-DIMMF1
P2-DIMME1
P2-DIMMH1
P2-DIMMG2
P2-DIMMH2
SXB1:CPU2 PCI-E X32
PROPRIENTAR SLOT
P2-DIMMG1
JPW3
CPU2
Rear_FAN
PS_ON_N
JPW2
CLOSE 1st
OPEN 1st
FAN3
FAN4
FAN2
FAN5
FAN6
FAN1
FAN8
FAN7
HDD
JPW1 PWR1
Front Panel I/O Port Locations and Definitions
X9DRFF-iG+/iTG+/7G+/7TG+ I/O Front Panel
1. Front Panel USB Port 1
2. Front Panel USB Port 2
3. IPMI LAN
4. 10-Gigabit LAN 1 (for X9DRFF-iTG+/-7TG+),
1-Gigabit LAN 1 (X9DRFF-iG+/-7G+)
5. 10-Gigabit LAN 2 (X9DRFF-iTG+/-7TG+),
1-Gigabit LAN 2 (X9DRFF-iG+/-7G+)
6. VGA
7. Power Switch (Button)
2-18
6
7
Chapter 2: Installation
Universal Serial Bus (USB)
Front Panel USB 0/1
& Type A USB 2
Pin Definitions
Two Universal Serial Bus ports (USB0,
USB1), located on the I/O front panel,
Pin# Definition
provide front-accessible USB support.
In addition, a Type A USB connector
(JUSB2), located next to the 4-pin
JIPMB1 connector, also provides
front-accessible USB support.
1
+5V
2
PO-
3
PO+
4
Ground
Video Connection
A Video (VGA) port is located next
to the LAN Port 2 on the I/O front
panel. Refer to the layout below for
the location.
1. USB0
JPG1
JPB1
USB1
LAN2
HDD_ACT_LED1
3. USB2
4. VGA
IPMI CODE
MAC CODE
CPLD1
BIOS
MEGERAC LICENSE
Intel PCH
SAS CODE
LEDS2
JBT1
JPS1
X9DRFF-iG+
PCH SLOT4 PCIE-E 2.0X4
BMC_HB_LED1
JP6
JBR1
JIPMB1 JPI2C1
CPU1 SLOT3 PCI-E 3.0X8
1
LSI SAS
CTRL
Rev. 1.01
JBAT1
JSD1
P1-DIMMA1
6-SGPIO2
6-SGPIO1
T-SGPIO2
T-SGPIO1
P1-DIMMB2
P1-DIMMB1
P1-DIMMA2
I-SATA5 L-SAS6 L-SAS7
I-SATA4 L-SAS4 L-SAS5
I-SATA3 L-SAS2 L-SAS3
I-SATA2 L-SAS0 L-SAS1
I-SATA0 I-SATA1
P1-DIMMD2
P1-DIMMD1
HDD_PWR2
P1-DIMMC1
P1-DIMMC2
CPU1 SLOT2 PCI-E 3.0X8
CPU1 SLOT1 PCI-E X16 PROPRIETARY SLOT
JP7
3
JWD1
JI2C2
JI2C1
USB2
BMC
2. USB1
IPMI_ LAN
LAN1
JPME2
USB0
PWR_SW1
UID_SW1
UID_LED1
FAILURE_LED1
JPL1
Intel LAN
CTRL
JPME1
VGA1
CPU1
CLOSE 1st
OPEN 1st
P2-DIMMF2
P2-DIMME2
P2-DIMMF1
P2-DIMME1
P2-DIMMH1
P2-DIMMG2
P2-DIMMH2
SXB1:CPU2 PCI-E X32
PROPRIENTAR SLOT
P2-DIMMG1
JPW3
CPU2
Rear_FAN
PS_ON_N
JPW2
CLOSE 1st
OPEN 1st
FAN3
FAN4
FAN2
FAN5
FAN6
FAN1
FAN8
FAN7
HDD
JPW1 PWR1
1
2
2-19
4
X9DRFF-iG+/iTG+/7G+/7TG+ Motherboard User’s Manual
Ethernet Ports
Two Ethernet ports (LAN1, LAN2) are
located on the I/O front panel. These
Ethernet ports support 10G LAN connections on the X9DRFF-iTG+/7TG+,
and 1G LAN connections on the
X9DRFF-iG+/7G+. In addition, an IPMI
LAN port is also located on the front
panel. All these ports accept RJ45
cables. Please refer to the LED Indicator Section for LAN LED information.
LAN Ports
Pin Definition
Pin# Definition
1
P2V5SB
10
SGND
2
TD0+
11
Act LED
3
TD0-
12
P3V3SB
4
TD1+
13
Link 100 LED (Yellow, +3V3SB)
5
TD1-
14
Link 1000 LED
(Yellow, +3V3SB)
6
TD2+
15
Ground
7
TD2-
16
Ground
8
TD3+
17
Ground
9
TD3-
18
Ground
1. IPMI LAN
JPG1
JPB1
USB1
LAN2
3. LAN2 (10G LAN: X9DRFF-iTG+/7TG+,
GLAN: X9DRFF-iG+/7G+)
IPMI CODE
MAC CODE
CPLD1
BIOS
MEGERAC LICENSE
Intel PCH
SAS CODE
LEDS2
JBT1
JPS1
X9DRFF-iG+
HDD_ACT_LED1
BMC
PCH SLOT4 PCIE-E 2.0X4
BMC_HB_LED1
JP6
JBR1
JIPMB1 JPI2C1
CPU1 SLOT3 PCI-E 3.0X8
1
LSI SAS
CTRL
Rev. 1.01
JBAT1
JSD1
P1-DIMMA1
6-SGPIO2
6-SGPIO1
T-SGPIO2
T-SGPIO1
P1-DIMMB2
P1-DIMMB1
P1-DIMMA2
I-SATA5 L-SAS6 L-SAS7
I-SATA4 L-SAS4 L-SAS5
I-SATA3 L-SAS2 L-SAS3
I-SATA2 L-SAS0 L-SAS1
I-SATA0 I-SATA1
P1-DIMMD2
P1-DIMMD1
HDD_PWR2
P1-DIMMC1
P1-DIMMC2
CPU1 SLOT2 PCI-E 3.0X8
CPU1 SLOT1 PCI-E X16 PROPRIETARY SLOT
JP7
JWD1
JI2C2
JI2C1
USB2
GLAN: X9DRFF-iG+/7G+)
IPMI_ LAN
LAN1
JPME2
2. LAN1(10G LAN: X9DRFF-iTG+/7TG+,
USB0
PWR_SW1
UID_SW1
UID_LED1
FAILURE_LED1
JPL1
Intel LAN
CTRL
JPME1
VGA1
CPU1
CLOSE 1st
OPEN 1st
P2-DIMME2
P2-DIMMF1
P2-DIMMF2
P2-DIMME1
P2-DIMMH1
SXB1:CPU2 PCI-E X32
PROPRIENTAR SLOT
P2-DIMMG2
P2-DIMMH2
P2-DIMMG1
JPW3
CPU2
Rear_FAN
PS_ON_N
JPW2
CLOSE 1st
OPEN 1st
FAN3
FAN4
FAN2
FAN5
FAN6
FAN1
FAN8
FAN7
HDD
JPW1 PWR1
1
2-20
2
3
Chapter 2: Installation
Power Button/Unit Identifier Switch
UID Switch
A Unit Identifier switch (SW1) and a UID LED
Indicator are located on the motherboard.
Pin#
Definition
1
Ground
In addition, a power button (PWR_SW1) is
located next to the UID switch on the front
panel. When you press the UID switch, the
UID LED Indicator will be turned on. Press
the UID switch again to turn off the UID LED.
The UID Indicator provides easy identification of a system unit that may be in need
of service.
2
Ground
3
Button In
4
Ground
Note: UID can also be triggered via
IPMI on the motherboard. For more
information on IPMI, please refer to
the IPMI User's Guide posted on
our website @ http://www.supermicro.com.
2 1
JPG1
USB1
LAN2
Windows OS
Unit Identified
Blue:
Blinking
Linux OS
Unit Identified
IPMI CODE
MEGERAC LICENSE
Intel PCH
2. UID Switch/UID LED (UID_LED1)
MAC CODE
CPLD1
BIOS
SAS CODE
LEDS2
JBT1
JPS1
X9DRFF-iG+
HDD_ACT_LED1
BMC
PCH SLOT4 PCIE-E 2.0X4
BMC_HB_LED1
JP6
JBR1
JIPMB1 JPI2C1
CPU1 SLOT3 PCI-E 3.0X8
1
LSI SAS
CTRL
Rev. 1.01
JBAT1
JSD1
P1-DIMMA1
P1-DIMMA2
6-SGPIO2
6-SGPIO1
T-SGPIO2
T-SGPIO1
P1-DIMMB2
P1-DIMMB1
I-SATA5 L-SAS6 L-SAS7
I-SATA4 L-SAS4 L-SAS5
I-SATA3 L-SAS2 L-SAS3
I-SATA2 L-SAS0 L-SAS1
I-SATA0 I-SATA1
P1-DIMMD2
P1-DIMMD1
HDD_PWR2
P1-DIMMC1
P1-DIMMC2
CPU1 SLOT2 PCI-E 3.0X8
CPU1 SLOT1 PCI-E X16 PROPRIETARY SLOT
JP7
JWD1
JI2C2
JI2C1
USB2
Blue: On
IPMI_ LAN
LAN1
JPME2
USB0
VGA1
JPB1
JPME1
Color/State OS Status
1. Power Button
PWR_SW1
UID_SW1
UID_LED1
FAILURE_LED1
JPL1
Intel LAN
CTRL
UID LED
Status
CPU1
CLOSE 1st
OPEN 1st
P2-DIMME2
P2-DIMMF1
P2-DIMMF2
P2-DIMME1
P2-DIMMH1
SXB1:CPU2 PCI-E X32
PROPRIENTAR SLOT
P2-DIMMG2
P2-DIMMH2
P2-DIMMG1
JPW3
CPU2
Rear_FAN
PS_ON_N
JPW2
CLOSE 1st
OPEN 1st
FAN2
FAN3
FAN4
FAN5
FAN6
FAN1
FAN8
FAN7
1
HDD
JPW1 PWR1
2-21
X9DRFF-iG+/iTG+/7G+/7TG+ Motherboard User’s Manual
2-7 Connecting Cables
Two 8-pin power connectors (JPW1/JPW2)
and a 4-pin power connector (JPW3) are
located on the motherboard. In addition, two
8-pin power connectors (HDD_PWR1/2) are
also located onboard to provide power supply
from the motherboard to the HDD backplane
for HDD device use. Do not use these connectors for other purposes. All power connectors mentioned above meet the SSI EPS
12V specification. See the tables on the right
for pin definitions.
JPG1
JPB1
USB1
LAN2
JBT1
LSI SAS
CTRL
JBAT1
JSD1
P1-DIMMA1
P1-DIMMA2
P1-DIMMB2
P1-DIMMB1
I-SATA5 L-SAS6 L-SAS7
I-SATA4 L-SAS4 L-SAS5
I-SATA3 L-SAS2 L-SAS3
I-SATA2 L-SAS0 L-SAS1
I-SATA0 I-SATA1
P1-DIMMD2
P1-DIMMD1
HDD_PWR2
P1-DIMMC1
P1-DIMMC2
6-SGPIO2
6-SGPIO1
T-SGPIO2
T-SGPIO1
E
CPU1
CLOSE 1st
OPEN 1st
P2-DIMME2
P2-DIMMF1
P2-DIMMF2
P2-DIMME1
P2-DIMMH1
SXB1:CPU2 PCI-E X32
PROPRIENTAR SLOT
P2-DIMMG2
B
P2-DIMMH2
JPW3
P2-DIMMG1
C
CPU2
Rear_FAN
PS_ON_N
JPW2
CLOSE 1st
OPEN 1st
A
FAN3
FAN4
FAN2
FAN5
FAN6
FAN1
FAN8
FAN7
Ground
5-8
+12V
2
Ground
3
5V SB
4
PS_ON_N
HDD PWR
Pin Definitions
Definition
Pins Definition
1- 4
Ground
5-6
+12V
7-8
+5V
E. HDD_PWR2 (8-pin)
LEDS2
JPS1
X9DRFF-iG+
1
D. HDD_ PWR1 (8-pin)
SAS CODE
Rev. 1.01
Ground
C. JPW3 (4-pin Power Connector)
IPMI CODE
MEGERAC LICENSE
Intel PCH
Pins
1- 4
B. JPW2 (8-pin Power Connector)
MAC CODE
CPLD1
BIOS
HDD_ACT_LED1
BMC
PCH SLOT4 PCIE-E 2.0X4
BMC_HB_LED1
JP6
JBR1
JIPMB1 JPI2C1
CPU1 SLOT3 PCI-E 3.0X8
1
CPU1 SLOT2 PCI-E 3.0X8
CPU1 SLOT1 PCI-E X16 PROPRIETARY SLOT
JP7
JWD1
JI2C2
JI2C1
USB2
Pins Definition
A. JPW1 (8-pin Power Connector)
IPMI_ LAN
LAN1
JPME2
12V 4-pin PWR
Pin Definitions
(Required)
USB0
PWR_SW1
UID_SW1
UID_LED1
FAILURE_LED1
JPL1
Intel LAN
CTRL
JPME1
VGA1
12V 8-pin PWR
Pin Definitions
D
HDD
JPW1 PWR1
2-22
Chapter 2: Installation
Fan Headers
This motherboard has eight 4-pin
(FAN1~FAN8), and one 3-pin (Rear_FAN1)
system/CPU/cooling fan headers on the
motherboard. The 4-pin fan headers are
backward compatible with the traditional
3-pin fans. However, fan speed control
is only available on 4-pin fans via IPMI
firmware management. See the table on
the right for pin definitions.
JPG1
JPB1
USB1
LAN2
MEGERAC LICENSE
Intel PCH
SAS CODE
LEDS2
JBT1
JPS1
X9DRFF-iG+
IPMI CODE
MAC CODE
CPLD1
BIOS
PCH SLOT4 PCIE-E 2.0X4
BMC_HB_LED1
CPU1 SLOT3 PCI-E 3.0X8
JP6
JBR1
JIPMB1 JPI2C1
LSI SAS
CTRL
Rev. 1.01
JBAT1
JSD1
6-SGPIO2
6-SGPIO1
T-SGPIO2
T-SGPIO1
P1-DIMMA1
P1-DIMMA2
P1-DIMMB1
I-SATA5 L-SAS6 L-SAS7
I-SATA4 L-SAS4 L-SAS5
I-SATA3 L-SAS2 L-SAS3
I-SATA2 L-SAS0 L-SAS1
I-SATA0 I-SATA1
P1-DIMMD2
P1-DIMMD1
HDD_PWR2
P1-DIMMB2
P1-DIMMC1
P1-DIMMC2
CPU1 SLOT2 PCI-E 3.0X8
CPU1 SLOT1 PCI-E X16 PROPRIETARY SLOT
JP7
1
BMC
HDD_ACT_LED1
JPME2
JWD1
JI2C2
JI2C1
USB2
CPU1
CLOSE 1st
OPEN 1st
P2-DIMMF2
P2-DIMME2
P2-DIMMF1
P2-DIMME1
P2-DIMMH1
P2-DIMMH2
SXB1:CPU2 PCI-E X32
PROPRIENTAR SLOT
B
P2-DIMMG2
P2-DIMMG1
JPW3
CPU2
Rear_FAN
PS_ON_N
JPW2
CLOSE 1st
OPEN 1st
A
FAN2
FAN3
FAN4
FAN5
FAN6
FAN1
FAN8
FAN7
Definition
1
Ground
2
+12V
3
Tachometer
4
PWR Modulation
(Available for 4-pin
fans only)
B. Rear_FAN 1
IPMI_ LAN
LAN1
Pin#
A. FAN1-FAN8
USB0
PWR_SW1
UID_SW1
UID_LED1
FAILURE_LED1
JPL1
Intel LAN
CTRL
JPME1
VGA1
Fan Header
Pin Definitions
HDD
JPW1 PWR1
2-23
X9DRFF-iG+/iTG+/7G+/7TG+ Motherboard User’s Manual
IPMB
IPMB Header
Pin Definitions
A System Management Bus header for
IPMI 2.0 is located at JIPMB1. Connect
Pin#
Definition
the appropriate cable here to use the
IPMB I2C connection on your system.
1
Data
2
Ground
3
Clock
4
No Connection
SATA Device Power Connector
A power connector for SATA DOM
(Disk_On_Module) devices is located
at JSD1. Connect an appropriate cable
here to provide power support for your
SATA DOM devices.
JPG1
JPB1
USB1
LAN2
MEGERAC LICENSE
Intel PCH
SAS CODE
LEDS2
JBT1
JPS1
X9DRFF-iG+
IPMI CODE
MAC CODE
CPLD1
BIOS
HDD_ACT_LED1
BMC
PCH SLOT4 PCIE-E 2.0X4
BMC_HB_LED1
JP6
JBR1
JIPMB1 JPI2C1
CPU1 SLOT3 PCI-E 3.0X8
1
LSI SAS
CTRL
Rev. 1.01
JBAT1
B
JSD1
P1-DIMMA1
6-SGPIO2
6-SGPIO1
T-SGPIO2
T-SGPIO1
P1-DIMMB2
P1-DIMMB1
P1-DIMMA2
I-SATA5 L-SAS6 L-SAS7
I-SATA4 L-SAS4 L-SAS5
I-SATA3 L-SAS2 L-SAS3
I-SATA2 L-SAS0 L-SAS1
I-SATA0 I-SATA1
P1-DIMMD2
P1-DIMMD1
HDD_PWR2
P1-DIMMC1
P1-DIMMC2
CPU1 SLOT2 PCI-E 3.0X8
CPU1 SLOT1 PCI-E X16 PROPRIETARY SLOT
A
JP7
JWD1
JI2C2
JI2C1
USB2
CPU1
CLOSE 1st
OPEN 1st
P2-DIMME2
P2-DIMMF1
P2-DIMMF2
P2-DIMME1
P2-DIMMH1
SXB1:CPU2 PCI-E X32
PROPRIENTAR SLOT
P2-DIMMG2
P2-DIMMH2
P2-DIMMG1
JPW3
CPU2
Rear_FAN
PS_ON_N
JPW2
CLOSE 1st
OPEN 1st
FAN3
FAN4
FAN2
FAN5
FAN6
FAN1
FAN8
FAN7
Definition
1
+5V
2
Ground
3
Ground
B. DOM PWR
IPMI_ LAN
LAN1
JPME2
Pin#
A. IPMB
USB0
PWR_SW1
UID_SW1
UID_LED1
FAILURE_LED1
JPL1
Intel LAN
CTRL
JPME1
VGA1
DOM PWR
Pin Definitions
HDD
JPW1 PWR1
2-24
Chapter 2: Installation
T-SGPIO 1/2 & 6-SGPIO 1/2 Headers
Four SGPIO (Serial-Link General Purpose Input/
Output) headers (T-SGPIO 1/2 & 6-SGPIO 1/2)
are located on the motherboard. These headers
support onboard Serial_Link interface connections.
Note: T-SGPIO 1/2 support onboard SATA
connections. 6-SGPIO 1/2 support SAS
interface on the X9DRFF-7G+/7TG+.
T-SGPIO/6-SGPIO
Pin Definitions
Pin#
Definition
Pin
Definition
2
NC
1
NC
4
Ground
3
Data
6
Load
5
Ground
8
Clock
7
NC
Note: NC= No Connection
PWR SMB
Pin Definitions
Power SMB (I2C) Connector
Power System Management Bus (I2C) Connector
(JPI2C1) monitors power supply, fan and system
temperatures. See the table on the right for pin
definitions.
JPG1
JPB1
USB1
LAN2
SAS CODE
JBAT1
JSD1
P1-DIMMA1
6-SGPIO2
6-SGPIO1
T-SGPIO2
T-SGPIO1
P1-DIMMB2
P1-DIMMB1
P1-DIMMA2
D
I-SATA5 L-SAS6 L-SAS7
I-SATA4 L-SAS4 L-SAS5
I-SATA3 L-SAS2 L-SAS3
I-SATA2 L-SAS0 L-SAS1
BC
I-SATA0 I-SATA1
P1-DIMMD2
P1-DIMMD1
HDD_PWR2
P1-DIMMC1
P1-DIMMC2
A
CPU1
CLOSE 1st
OPEN 1st
P2-DIMME2
P2-DIMMF2
P2-DIMMF1
P2-DIMME1
P2-DIMMH1
SXB1:CPU2 PCI-E X32
PROPRIENTAR SLOT
P2-DIMMG2
P2-DIMMH2
P2-DIMMG1
JPW3
CPU2
Rear_FAN
PS_ON_N
JPW2
CLOSE 1st
OPEN 1st
FAN3
FAN4
FAN2
FAN5
FAN6
FAN1
FAN8
FAN7
PWR Fail
4
Ground
5
+3.3V
E. JPI2C1
JPS1
LSI SAS
CTRL
Rev. 1.01
Data
3
D. 6-SGPIO 2
LEDS2
JBT1
2
C. 6-SGPIO 1
IPMI CODE
MEGERAC LICENSE
Intel PCH
Clock
B. T-SGPIO 2
MAC CODE
X9DRFF-iG+
HDD_ACT_LED1
CPLD1
BIOS
PCH SLOT4 PCIE-E 2.0X4
BMC_HB_LED1
CPU1 SLOT3 PCI-E 3.0X8
JP6
JBR1
JIPMB1 JPI2C1
E
CPU1 SLOT2 PCI-E 3.0X8
CPU1 SLOT1 PCI-E X16 PROPRIETARY SLOT
JP7
1
BMC
Definition
1
A. T-SGPIO1
IPMI_ LAN
LAN1
JPME2
JWD1
JI2C2
JI2C1
USB2
USB0
PWR_SW1
UID_SW1
UID_LED1
FAILURE_LED1
JPL1
Intel LAN
CTRL
JPME1
VGA1
Pin#
HDD
JPW1 PWR1
2-25
X9DRFF-iG+/iTG+/7G+/7TG+ Motherboard User’s Manual
Power Switch
A Power switch is located next to the UID switch on the motherboard. Refer to the
layout below for the location.
Unit Identification Switch/LED
A Unit Identifier switch (UID) and a UID LED indicator (UID_LED1) are located next to the power
switch on the front panel. When the user pushes
the UID switch, the UID LED (UID_LED1) will be
turned on. Push the UID switch again to turn off
the LED indicator. The UID switch provides easy
identification of a system unit that may be in need
of service. See the tables on the right for more
information.
UID Switch (UID)
Pin Definitions
Pin# Definition
1
Ground
2
Ground
3
Button In
4
Ground
B A
JPG1
JPB1
USB1
LAN2
MEGERAC LICENSE
Intel PCH
SAS CODE
LEDS2
JBT1
JPS1
X9DRFF-iG+
IPMI CODE
MAC CODE
CPLD1
BIOS
HDD_ACT_LED1
BMC
PCH SLOT4 PCIE-E 2.0X4
BMC_HB_LED1
JP6
JBR1
JIPMB1 JPI2C1
CPU1 SLOT3 PCI-E 3.0X8
1
LSI SAS
CTRL
Rev. 1.01
JBAT1
JSD1
6-SGPIO2
6-SGPIO1
T-SGPIO2
T-SGPIO1
P1-DIMMA1
P1-DIMMA2
P1-DIMMB2
P1-DIMMB1
I-SATA5 L-SAS6 L-SAS7
I-SATA4 L-SAS4 L-SAS5
I-SATA3 L-SAS2 L-SAS3
I-SATA2 L-SAS0 L-SAS1
I-SATA0 I-SATA1
P1-DIMMD2
P1-DIMMD1
HDD_PWR2
P1-DIMMC1
P1-DIMMC2
CPU1 SLOT2 PCI-E 3.0X8
CPU1 SLOT1 PCI-E X16 PROPRIETARY SLOT
JP7
JWD1
JI2C2
JI2C1
USB2
B. UID SW/LED
IPMI_ LAN
LAN1
JPME2
A. PWR Switch
USB0
PWR_SW1
UID_SW1
UID_LED1
FAILURE_LED1
JPL1
Intel LAN
CTRL
JPME1
VGA1
CPU1
CLOSE 1st
OPEN 1st
P2-DIMMF2
P2-DIMME2
P2-DIMMF1
P2-DIMME1
P2-DIMMH1
P2-DIMMH2
SXB1:CPU2 PCI-E X32
PROPRIENTAR SLOT
P2-DIMMG2
P2-DIMMG1
JPW3
CPU2
Rear_FAN
PS_ON_N
JPW2
CLOSE 1st
OPEN 1st
FAN2
FAN3
FAN4
FAN5
FAN6
FAN1
FAN8
FAN7
HDD
JPW1 PWR1
2-26
Chapter 2: Installation
2-8 Jumper Settings
Explanation of Jumpers
Connector
Pins
To modify the operation of the motherboard, jumpers can be used to choose
between optional settings. Jumpers create
shorts between two pins to change the
function of the connector. Pin 1 is identified
with a square solder pad on the printed
circuit board. See the motherboard layout
pages for jumper locations.
3
2
1
3
2
1
Jumper
Cap
Setting
Pin 1-2 short
Not e: O n t wo - pin jumper s,
"Closed" means the jumper is
on and "Open" means the jumper
is off the pins.
GLAN Enable/Disable
JPL1 enables or disables LAN Port1/LAN Port2
on the motherboard. See the table on the
right for jumper settings. The default setting
is Enabled.
USB1
JPG1
JPB1
JPL1
Intel LAN
CTRL
JPME1
VGA1
LAN2
HDD_ACT_LED1
IPMI CODE
MEGERAC LICENSE
Intel PCH
SAS CODE
LEDS2
JBT1
JPS1
LSI SAS
CTRL
Rev. 1.01
JBAT1
JSD1
P1-DIMMA1
6-SGPIO2
6-SGPIO1
T-SGPIO2
T-SGPIO1
P1-DIMMB2
P1-DIMMB1
P1-DIMMA2
I-SATA5 L-SAS6 L-SAS7
I-SATA4 L-SAS4 L-SAS5
I-SATA3 L-SAS2 L-SAS3
I-SATA2 L-SAS0 L-SAS1
I-SATA0 I-SATA1
P1-DIMMD2
P1-DIMMD1
HDD_PWR2
P1-DIMMC1
P1-DIMMC2
CPU1
CLOSE 1st
OPEN 1st
P2-DIMME2
P2-DIMMF2
P2-DIMMF1
P2-DIMME1
P2-DIMMH1
SXB1:CPU2 PCI-E X32
PROPRIENTAR SLOT
P2-DIMMG2
P2-DIMMG1
P2-DIMMH2
JPW3
CPU2
Rear_FAN
PS_ON_N
JPW2
CLOSE 1st
OPEN 1st
FAN3
FAN4
FAN2
FAN5
FAN6
FAN1
FAN8
FAN7
Enabled (default)
2-3
Disabled
A. LAN1/2 Enable
MAC CODE
CPLD1
BIOS
X9DRFF-iG+
PCH SLOT4 PCIE-E 2.0X4
BMC_HB_LED1
CPU1 SLOT3 PCI-E 3.0X8
JP6
JBR1
JIPMB1 JPI2C1
CPU1 SLOT2 PCI-E 3.0X8
CPU1 SLOT1 PCI-E X16 PROPRIETARY SLOT
JP7
1
BMC
1-2
IPMI_ LAN
LAN1
JPME2
JWD1
JI2C2
JI2C1
USB2
Jumper Setting Definition
USB0
PWR_SW1
UID_SW1
UID_LED1
FAILURE_LED1
A
LAN Enable
Jumper Settings
HDD
JPW1 PWR1
2-27
X9DRFF-iG+/iTG+/7G+/7TG+ Motherboard User’s Manual
CMOS Clear
JBT1 is used to clear CMOS. Instead of pins, this "jumper" consists of contact pads
to prevent accidental clearing of CMOS. To clear CMOS, use a metal object such
as a small screwdriver to touch both pads at the same time to short the connection.
Always remove the AC power cord from the system before clearing CMOS.
Note 1: For an ATX power supply, you must completely shut down the
system, remove the AC power cord, and then short JBT1 to clear CMOS.
Note 2: Be sure to remove the onboard CMOS Battery before you short
JBT1 to clear CMOS.
Note 3: Clearing CMOS will also clear all passwords.
Watch Dog Enable/Disable
Watch Dog (JWD1) is a system monitor that will reboot the system when a software application hangs.
Close pins 1-2 to reset the system if an application
hangs. Close pins 2-3 to generate a non-maskable
interrupt signal for the application that hangs. See
the table on the right for jumper settings. Watch Dog
must also be enabled in the BIOS.
JPG1
JPB1
USB1
LAN2
JBT1
Rev. 1.01
SAS CODE
LEDS2
A
JPS1
X9DRFF-iG+
MEGERAC LICENSE
Intel PCH
LSI SAS
CTRL
JBAT1
JSD1
P1-DIMMA1
6-SGPIO2
6-SGPIO1
T-SGPIO2
T-SGPIO1
P1-DIMMB2
P1-DIMMB1
P1-DIMMA2
I-SATA5 L-SAS6 L-SAS7
I-SATA4 L-SAS4 L-SAS5
I-SATA3 L-SAS2 L-SAS3
I-SATA2 L-SAS0 L-SAS1
I-SATA0 I-SATA1
P1-DIMMD2
P1-DIMMD1
HDD_PWR2
P1-DIMMC1
P1-DIMMC2
CPU1
CLOSE 1st
OPEN 1st
P2-DIMMF2
P2-DIMME2
P2-DIMMF1
P2-DIMME1
P2-DIMMH1
P2-DIMMG2
P2-DIMMH2
SXB1:CPU2 PCI-E X32
PROPRIENTAR SLOT
P2-DIMMG1
JPW3
CPU2
Rear_FAN
PS_ON_N
JPW2
CLOSE 1st
OPEN 1st
FAN3
FAN4
FAN2
FAN5
FAN6
FAN1
FAN8
FAN7
Definition
Pins 1-2
Reset (default)
Pins 2-3
NMI
Open
Disabled
B. Watch Dog Enable
IPMI CODE
MAC CODE
CPLD1
JP6
JBR1
JIPMB1 JPI2C1
BIOS
HDD_ACT_LED1
BMC
PCH SLOT4 PCIE-E 2.0X4
JP7
1
BMC_HB_LED1
CPU1 SLOT3 PCI-E 3.0X8
CPU1 SLOT2 PCI-E 3.0X8
CPU1 SLOT1 PCI-E X16 PROPRIETARY SLOT
B
JWD1
JI2C2
JI2C1
USB2
Jumper Setting
A. Clear CMOS
IPMI_ LAN
LAN1
JPME2
USB0
PWR_SW1
UID_SW1
UID_LED1
FAILURE_LED1
JPL1
Intel LAN
CTRL
JPME1
VGA1
Watch Dog
Jumper Settings
HDD
JPW1 PWR1
2-28
Chapter 2: Installation
VGA Enable
Jumper JPG1 allows the user to enable onboard VGA support. The default
setting is on Pins 1-2 to enable VGA
support. See the table on the right for
jumper settings.
BMC Enable
Jumper JPB1 allows you to enable the
embedded BMC (Baseboard Management) Controller to provide IPMI 2.0 support on the motherboard. See the table
on the right for jumper settings.
JPG1
JPB1
USB1
B
LAN2
MEGERAC LICENSE
Intel PCH
SAS CODE
LEDS2
JBT1
JPS1
X9DRFF-iG+
IPMI CODE
MAC CODE
CPLD1
BIOS
PCH SLOT4 PCIE-E 2.0X4
BMC_HB_LED1
CPU1 SLOT3 PCI-E 3.0X8
JP6
JBR1
JIPMB1 JPI2C1
LSI SAS
CTRL
Rev. 1.01
JBAT1
JSD1
6-SGPIO2
6-SGPIO1
T-SGPIO2
T-SGPIO1
P1-DIMMA1
P1-DIMMA2
P1-DIMMB2
P1-DIMMB1
I-SATA5 L-SAS6 L-SAS7
I-SATA4 L-SAS4 L-SAS5
I-SATA3 L-SAS2 L-SAS3
I-SATA2 L-SAS0 L-SAS1
I-SATA0 I-SATA1
P1-DIMMD2
P1-DIMMD1
HDD_PWR2
P1-DIMMC1
P1-DIMMC2
CPU1 SLOT2 PCI-E 3.0X8
CPU1 SLOT1 PCI-E X16 PROPRIETARY SLOT
JP7
1
BMC
HDD_ACT_LED1
JPME2
JWD1
JI2C2
JI2C1
USB2
CPU1
CLOSE 1st
OPEN 1st
P2-DIMME2
P2-DIMMF2
P2-DIMMF1
P2-DIMME1
P2-DIMMH1
SXB1:CPU2 PCI-E X32
PROPRIENTAR SLOT
P2-DIMMG2
P2-DIMMH2
P2-DIMMG1
JPW3
CPU2
Rear_FAN
PS_ON_N
JPW2
CLOSE 1st
OPEN 1st
FAN2
FAN3
FAN4
FAN5
FAN6
FAN1
FAN8
FAN7
Definition
1-2
Enabled (Default)
2-3
Disabled
BMC Enable
Jumper Settings
Jumper Setting
Definition
Pins 1-2
BMC Enable
Pins 2-3
Normal (Default)
B. BMC Enabled
IPMI_ LAN
LAN1
Jumper Setting
A. VGA Enabled
USB0
PWR_SW1
UID_SW1
UID_LED1
FAILURE_LED1
JPL1
Intel LAN
CTRL
JPME1
VGA1
A
VGA Enable
Jumper Settings
HDD
JPW1 PWR1
2-29
X9DRFF-iG+/iTG+/7G+/7TG+ Motherboard User’s Manual
Management Engine (ME) Recovery
Use Jumper JPME1 to select ME Firmware Recovery mode, which will limit
resource allocation for essential system
operation only in order to maintain normal power operation and management.
In the single operation mode, online
upgrade will be available via Recovery
mode. See the table on the right for
jumper settings.
ME Recovery
Jumper Settings
Jumper Setting
Normal (Default)
2-3
ME Recovery
Manufacture Mode Select
Close Pin 2 and Pin 3 of Jumper JPME2
to bypass SPI flash security and force
the system to operate in the Manufacture Mode, allowing the user to flash the
system firmware from a host server for
system setting modifications. See the
table on the right for jumper settings.
JPG1
JPB1
LAN2
MEGERAC LICENSE
Intel PCH
SAS CODE
LEDS2
JBT1
JPS1
X9DRFF-iG+
IPMI CODE
MAC CODE
CPLD1
JP6
JBR1
JIPMB1 JPI2C1
BIOS
HDD_ACT_LED1
BMC
PCH SLOT4 PCIE-E 2.0X4
BMC_HB_LED1
1
CPU1 SLOT3 PCI-E 3.0X8
JP7
JWD1
JI2C2
JI2C1
USB2
LSI SAS
CTRL
Rev. 1.01
JBAT1
JSD1
P1-DIMMA1
6-SGPIO2
6-SGPIO1
T-SGPIO2
T-SGPIO1
P1-DIMMB1
P1-DIMMA2
P1-DIMMB2
I-SATA5 L-SAS6 L-SAS7
I-SATA4 L-SAS4 L-SAS5
I-SATA3 L-SAS2 L-SAS3
I-SATA2 L-SAS0 L-SAS1
I-SATA0 I-SATA1
P1-DIMMD2
P1-DIMMD1
HDD_PWR2
P1-DIMMC1
P1-DIMMC2
CPU1
CLOSE 1st
OPEN 1st
P2-DIMME2
P2-DIMMF2
P2-DIMMF1
P2-DIMME1
P2-DIMMH1
SXB1:CPU2 PCI-E X32
PROPRIENTAR SLOT
P2-DIMMG2
P2-DIMMH2
P2-DIMMG1
JPW3
CPU2
Rear_FAN
PS_ON_N
JPW2
CLOSE 1st
OPEN 1st
FAN3
FAN4
FAN2
FAN5
FAN6
FAN1
FAN8
FAN7
Jumper Setting
HDD
JPW1 PWR1
2-30
Definition
1-2
Normal (Default)
2-3
Manufacture Mode
B. JPME2
IPMI_ LAN
LAN1
ME Mode Select
Jumper Settings
A. JPME1
USB0
PWR_SW1
UID_SW1
UID_LED1
FAILURE_LED1
Intel LAN
CTRL
JPME1
USB1
JPME2
CPU1 SLOT2 PCI-E 3.0X8
CPU1 SLOT1 PCI-E X16 PROPRIETARY SLOT
B
JPL1
A
VGA1
Definition
1-2
Chapter 2: Installation
I2C Bus to PCI-Exp. Slots
I2C to PCI-Exp
Jumper Settings
Jumpers JI C1 and JI C2 allow you to
connect the System Management Bus
2
2
Jumper Setting
(I2C) to PCI-Express slots. The default
setting is Open to disable the connection.
Enabled
Open
Disabled (Default)
SAS Enable (For X9DRFF-7G+/7TG+)
SAS Support Enable
Jumper Settings
Use Jumper JPS1 to enable onboard
SAS support to enhance system performance. The default setting is enabled.
JPG1
JPB1
USB1
LAN2
MEGERAC LICENSE
Intel PCH
SAS CODE
LEDS2
JBT1
JPS1
X9DRFF-iG+
IPMI CODE
MAC CODE
CPLD1
JP6
JBR1
JIPMB1 JPI2C1
BIOS
HDD_ACT_LED1
BMC
PCH SLOT4 PCIE-E 2.0X4
JP7
1
BMC_HB_LED1
CPU1 SLOT3 PCI-E 3.0X8
LSI SAS
CTRL
Rev. 1.01
JBAT1
C
JSD1
6-SGPIO2
6-SGPIO1
T-SGPIO2
T-SGPIO1
P1-DIMMA2
P1-DIMMB2
P1-DIMMB1
I-SATA5 L-SAS6 L-SAS7
I-SATA4 L-SAS4 L-SAS5
I-SATA3 L-SAS2 L-SAS3
I-SATA2 L-SAS0 L-SAS1
I-SATA0 I-SATA1
P1-DIMMD2
P1-DIMMD1
HDD_PWR2
P1-DIMMC1
P1-DIMMC2
P1-DIMMA1
CPU1 SLOT2 PCI-E 3.0X8
CPU1 SLOT1 PCI-E X16 PROPRIETARY SLOT
B
A
CPU1
CLOSE 1st
OPEN 1st
P2-DIMME2
P2-DIMMF2
P2-DIMMF1
P2-DIMME1
SXB1:CPU2 PCI-E X32
PROPRIENTAR SLOT
P2-DIMMH1
P2-DIMMG2
P2-DIMMH2
P2-DIMMG1
JPW3
CPU2
Rear_FAN
PS_ON_N
JPW2
CLOSE 1st
OPEN 1st
FAN2
FAN3
FAN4
FAN5
FAN6
FAN1
FAN8
FAN7
Definition
Pins 1/2
SAS Enabled (Default)
Pins 2/3
SAS Disabled
A. JI2C1
B. JI2C2
C. SAS Enable
IPMI_ LAN
LAN1
JPME2
JWD1
JI2C2
JI2C1
USB2
Jumper Setting
USB0
PWR_SW1
UID_SW1
UID_LED1
FAILURE_LED1
JPL1
Intel LAN
CTRL
JPME1
VGA1
Definition
Closed
HDD
JPW1 PWR1
2-31
X9DRFF-iG+/iTG+/7G+/7TG+ Motherboard User’s Manual
2-9 Onboard LED Indicators
Activity LED
Link Speed LED
GLAN LEDs
There are two LAN ports (LAN1/2) on the
motherboard. Each Ethernet LAN port has
two LEDs. The Yellow LED on the right
indicates connection and activity. The
Link LED on the left side may be green,
amber or off to indicate the speed of the
connection. See the table on the right for
more information.
Front View (when facing the
front side of the chassis)
GLAN/TLAN Activity Indicator (Right)
LED Settings
Color
Status
Off
No Connections
Definition
Yellow
Flashing
Active
LAN 1/LAN 2
IPMI LAN
IPMI Dedicated LAN LEDs
In addition to LAN Ports 1/2, an IPMI
Dedicated LAN is also located on the I/O
front panel. The amber LED on the right
indicates connection and activity.
USB1
JPG1
JPB1
JPME1
VGA1
LAN2
BMC
SAS CODE
No Connection
Activity
Amber:
Blinking
Active
Speed
Green: Solid
100 Mbps
A. LAN1/2 LEDs
B. IPMI LAN LEDs
LEDS2
JBT1
JPS1
LSI SAS
CTRL
Rev. 1.01
JBAT1
JSD1
P1-DIMMA1
6-SGPIO2
6-SGPIO1
T-SGPIO2
T-SGPIO1
P1-DIMMB2
P1-DIMMB1
P1-DIMMA2
I-SATA5 L-SAS6 L-SAS7
I-SATA4 L-SAS4 L-SAS5
I-SATA3 L-SAS2 L-SAS3
I-SATA2 L-SAS0 L-SAS1
I-SATA0 I-SATA1
P1-DIMMD2
P1-DIMMD1
HDD_PWR2
P1-DIMMC1
P1-DIMMC2
CPU1
CLOSE 1st
OPEN 1st
P2-DIMME2
P2-DIMMF2
P2-DIMMF1
P2-DIMME1
P2-DIMMH1
SXB1:CPU2 PCI-E X32
PROPRIENTAR SLOT
P2-DIMMG2
P2-DIMMH2
P2-DIMMG1
JPW3
CPU2
Rear_FAN
PS_ON_N
JPW2
B
CLOSE 1st
OPEN 1st
FAN3
FAN4
FAN2
FAN5
FAN6
FAN1
FAN8
FAN7
HDD
JPW1 PWR1
2-32
Definition
Off
IPMI CODE
MEGERAC LICENSE
Intel PCH
Color/State
Off
MAC CODE
CPLD1
BIOS
X9DRFF-iG+
PCH SLOT4 PCIE-E 2.0X4
BMC_HB_LED1
JP6
JBR1
JIPMB1 JPI2C1
CPU1 SLOT3 PCI-E 3.0X8
1
CPU1 SLOT2 PCI-E 3.0X8
CPU1 SLOT1 PCI-E X16 PROPRIETARY SLOT
JP7
JWD1
JI2C2
JI2C1
USB2
HDD_ACT_LED1
JPME2
LED
IPMI_ LAN
LAN1
IPMI LAN
(X8ST3-F)
IPMI LAN Link Speed LED (Left) &
Connection Activity LED (Right)
USB0
PWR_SW1
UID_SW1
UID_LED1
FAILURE_LED1
JPL1
Intel LAN
CTRL
Activity LED
Link Speed LED
A
Chapter 2: Installation
HDD Activity LED
An HDD Activity LED is located at
HDD_ACT LED1 on the motherboard.
When the HDD LED is blinking, an HDD
device is active. See the table on the right
for more information.
HDD Activity LED
Status
Color or State
HDD: Active
Off
HDD Disabled,
or Failed
BMC Heartbeat LED
A BMC Heartbeat LED is located at
BMC_HB_LED1 on the motherboard.
When this LED indicator is blinking, BMC
is normal. See the table on the right for
more information.
JPG1
IPMI CODE
MAC CODE
MEGERAC LICENSE
Intel PCH
SAS CODE
LEDS2
JBT1
LSI SAS
CTRL
Rev. 1.01
JBAT1
JSD1
6-SGPIO2
6-SGPIO1
T-SGPIO2
T-SGPIO1
P1-DIMMA1
P1-DIMMA2
I-SATA5 L-SAS6 L-SAS7
I-SATA4 L-SAS4 L-SAS5
I-SATA3 L-SAS2 L-SAS3
I-SATA2 L-SAS0 L-SAS1
I-SATA0 I-SATA1
P1-DIMMD2
P1-DIMMD1
HDD_PWR2
P1-DIMMB2
P1-DIMMB1
P1-DIMMC1
P1-DIMMC2
CPU1
CLOSE 1st
OPEN 1st
P2-DIMMF2
P2-DIMME2
P2-DIMMF1
P2-DIMME1
P2-DIMMH1
SXB1:CPU2 PCI-E X32
PROPRIENTAR SLOT
P2-DIMMG2
P2-DIMMH2
P2-DIMMG1
JPW3
CPU2
Rear_FAN
PS_ON_N
JPW2
CLOSE 1st
OPEN 1st
FAN2
FAN3
FAN4
FAN5
FAN6
FAN1
FAN8
FAN7
Color or State
Definition
Green
BMC: Normal
Off
BMC Disabled,
or Failed
B. BMC_HB LED1
JPS1
X9DRFF-iG+
HDD_ACT_LED1
CPLD1
BIOS
PCH SLOT4 PCIE-E 2.0X4
BMC_HB_LED1
CPU1 SLOT3 PCI-E 3.0X8
JP6
JBR1
JIPMB1 JPI2C1
CPU1 SLOT2 PCI-E 3.0X8
CPU1 SLOT1 PCI-E X16 PROPRIETARY SLOT
JP7
1
A
BMC
BMC Heartbeat LED
Status
A. HDD_ACT LED1
IPMI_ LAN
LAN1
LAN2
B
JPME2
JWD1
JI2C2
JI2C1
USB2
JPB1
JPME1
USB1
USB0
PWR_SW1
UID_SW1
UID_LED1
FAILURE_LED1
JPL1
Intel LAN
CTRL
VGA1
Definition
Green: Blinking
HDD
JPW1 PWR1
2-33
X9DRFF-iG+/iTG+/7G+/7TG+ Motherboard User’s Manual
SAS Heartbeat LED
SAS Heartbeat LED
Status
A SAS Heartbeat LED is located at
LEDS2 on the motherboard. When
Color/State
LEDS2 is blinking, SAS is working
properly.
Green: Blinking
SAS: Normal
Off or Red
SAS: Disabled or
Failed
Failure LED
A Failure LED is located at Failure_LED1
on the motherboard. When Failure_LED1
is on, power failure has occurred. When
it is blinking, it indicates a fan failure.
See the table on the right for more information.
LAN2
MEGERAC LICENSE
Intel PCH
SAS CODE
LEDS2
JBT1
LSI SAS
CTRL
Rev. 1.01
JBAT1
A
JPS1
X9DRFF-iG+
IPMI CODE
MAC CODE
CPLD1
BIOS
PCH SLOT4 PCIE-E 2.0X4
BMC_HB_LED1
CPU1 SLOT3 PCI-E 3.0X8
JP6
JBR1
JIPMB1 JPI2C1
JSD1
6-SGPIO2
6-SGPIO1
T-SGPIO2
T-SGPIO1
P1-DIMMA1
P1-DIMMA2
P1-DIMMB2
P1-DIMMB1
I-SATA5
I-SATA4
I-SATA3
I-SATA2
CPU1
CLOSE 1st
L-SAS6
L-SAS4
L-SAS2
L-SAS0
I-SATA0 I-SATA1
P1-DIMMD2
P1-DIMMD1
HDD_PWR2
P1-DIMMC1
P1-DIMMC2
CPU1 SLOT2 PCI-E 3.0X8
CPU1 SLOT1 PCI-E X16 PROPRIETARY SLOT
JP7
1
BMC
HDD_ACT_LED1
JPME2
JWD1
JI2C2
JI2C1
USB2
L-SAS7
L-SAS5
L-SAS3
L-SAS1
OPEN 1st
P2-DIMMF2
P2-DIMME2
P2-DIMMF1
P2-DIMME1
P2-DIMMH1
SXB1:CPU2 PCI-E X32
PROPRIENTAR SLOT
P2-DIMMG2
P2-DIMMH2
P2-DIMMG1
JPW3
CPU2
Rear_FAN
PS_ON_N
JPW2
CLOSE 1st
OPEN 1st
FAN2
FAN3
FAN4
FAN5
FAN6
FAN1
FAN8
FAN7
State
Definition
On
PWR Failure
Blinking
Fan Failure
B. Failure LED
IPMI_ LAN
LAN1
Failure LED
Status
A. SAS Heartbeat LED
USB0
USB1
JPG1
Intel LAN
CTRL
JPME1
VGA1
JPB1
JPL1
PWR_SW1
UID_SW1
UID_LED1
FAILURE_LED1
B
Definition
HDD
JPW1 PWR1
2-34
Chapter 2: Installation
UID LED
The Unit Identifier (UID) LED is located
at UID_LED1 on the motherboard. When
this LED is on, the unit that might be in
need of service is identified. See the
table on the right for more information.
UID LED
Status
Color/State
Blue: On
Definition
Unit Identified
Note: For information on the UID switch, refer to page 2-21.
A
JPG1
JPB1
USB1
LAN2
MEGERAC LICENSE
Intel PCH
SAS CODE
LEDS2
JBT1
JPS1
X9DRFF-iG+
IPMI CODE
MAC CODE
CPLD1
BIOS
HDD_ACT_LED1
BMC
PCH SLOT4 PCIE-E 2.0X4
BMC_HB_LED1
JP6
JBR1
JIPMB1 JPI2C1
CPU1 SLOT3 PCI-E 3.0X8
1
LSI SAS
CTRL
Rev. 1.01
JBAT1
JSD1
6-SGPIO2
6-SGPIO1
T-SGPIO2
T-SGPIO1
P1-DIMMA1
P1-DIMMA2
P1-DIMMB2
P1-DIMMB1
I-SATA5 L-SAS6 L-SAS7
I-SATA4 L-SAS4 L-SAS5
I-SATA3 L-SAS2 L-SAS3
I-SATA2 L-SAS0 L-SAS1
I-SATA0 I-SATA1
P1-DIMMD2
P1-DIMMD1
HDD_PWR2
P1-DIMMC1
P1-DIMMC2
CPU1 SLOT2 PCI-E 3.0X8
CPU1 SLOT1 PCI-E X16 PROPRIETARY SLOT
JP7
JWD1
JI2C2
JI2C1
USB2
IPMI_ LAN
LAN1
JPME2
A. UID LED
USB0
PWR_SW1
UID_SW1
UID_LED1
FAILURE_LED1
JPL1
Intel LAN
CTRL
JPME1
VGA1
CPU1
CLOSE 1st
OPEN 1st
P2-DIMME2
P2-DIMMF1
P2-DIMMF2
P2-DIMME1
P2-DIMMH1
SXB1:CPU2 PCI-E X32
PROPRIENTAR SLOT
P2-DIMMG2
P2-DIMMH2
P2-DIMMG1
JPW3
CPU2
Rear_FAN
PS_ON_N
JPW2
CLOSE 1st
OPEN 1st
FAN2
FAN3
FAN4
FAN5
FAN6
FAN1
FAN8
FAN7
HDD
JPW1 PWR1
2-35
X9DRFF-iG+/iTG+/7G+/7TG+ Motherboard User’s Manual
2-10 SATA/SAS Connections
SATA/SAS Ports
Six Serial_ATA ports are located on the motherboard.
I-SATA Ports 0/1 support SATA 3.0. I-SATA Ports 2-5
support SATA 2.0. In addition, eight SAS ports (L-SAS
0-7), supported by the LSI SAS 2308 Controller are also
located on the X9DRFF-7G+/7TG+. See the table on the
right for pin definitions.
Note: For more information on SATA HostRAID
configuration, please refer to the Intel SATA and
LSI SAS HostRAID User's Guides posted on our
website @ http://www.supermicro.com..
JPG1
JPB1
JPME1
USB1
LAN2
BMC
LEDS2
JPS1
X9DRFF-iG+
IPMI CODE
SAS CODE
JBT1
LSI SAS
CTRL
Rev. 1.01
JBAT1
JSD1
6-SGPIO2
6-SGPIO1
T-SGPIO2
T-SGPIO1
P1-DIMMA1
P1-DIMMA2
P1-DIMMB2
P1-DIMMB1
B
CLOSE 1st
I-SATA5 L-SAS6 L-SAS7
I-SATA4 L-SAS4 L-SAS5
I-SATA3 L-SAS2 L-SAS3
I-SATA2 L-SAS0 L-SAS1
I-SATA0 I-SATA1
P1-DIMMD2
P1-DIMMD1
HDD_PWR2
P1-DIMMC1
P1-DIMMC2
C
A
CPU1
D
OPEN 1st
P2-DIMMF2
P2-DIMME2
P2-DIMMF1
P2-DIMME1
P2-DIMMH1
SXB1:CPU2 PCI-E X32
PROPRIENTAR SLOT
P2-DIMMG2
P2-DIMMH2
P2-DIMMG1
JPW3
CPU2
Rear_FAN
PS_ON_N
JPW2
CLOSE 1st
OPEN 1st
FAN2
FAN3
FAN4
FAN5
FAN6
FAN1
FAN8
FAN7
2
TX_P
3
TX_N
4
Ground
5
RX_N
6
RX_P
7
Ground
D. L-SAS0-7 (X9DRFF-7G+/7TG+)
MEGERAC LICENSE
Intel PCH
Ground
C. I-SATA2-5 (SATA 2.0)
MAC CODE
CPLD1
BIOS
PCH SLOT4 PCIE-E 2.0X4
BMC_HB_LED1
JP6
JBR1
JIPMB1 JPI2C1
CPU1 SLOT3 PCI-E 3.0X8
1
CPU1 SLOT2 PCI-E 3.0X8
CPU1 SLOT1 PCI-E X16 PROPRIETARY SLOT
JP7
JWD1
JI2C2
JI2C1
USB2
HDD_ACT_LED1
JPME2
Definition
1
B. I-SATA1 (SATA 3.0)
IPMI_ LAN
LAN1
Pin#
A. I-SATA0 (SATA 3.0)
USB0
PWR_SW1
UID_SW1
UID_LED1
FAILURE_LED1
JPL1
Intel LAN
CTRL
VGA1
SATA/SAS
Pin Definitions
HDD
JPW1 PWR1
2-36
Chapter 3: Troubleshooting
Chapter 3
Troubleshooting
3-1 Troubleshooting Procedures
Use the following procedures to troubleshoot your system. If you have followed all
of the procedures below and still need assistance, refer to the ‘Technical Support
Procedures’ and/or ‘Returning Merchandise for Service’ section(s) in this chapter.
Note: Always disconnect the power cord before adding, changing or installing any hardware components.
Before Power On
1. Make sure that there are no short circuits between the motherboard and
chassis.
2. Disconnect all ribbon/wire cables from the motherboard, including those for
the keyboard and mouse.
3. Remove all add-on cards.
4. Install CPU 1 first (making sure it is fully seated) and connect the front panel
connectors to the motherboard.
No Power
1. Make sure that no short circuits between the motherboard and the chassis.
2. Make sure that the ATX power connectors are properly connected
3. Check that the 115V/230V switch on the power supply is properly set, if available.
4. Turn the power switch on and off to test the system, if applicable.
5. The battery on your motherboard may be old. Check to verify that it still supplies ~3VDC. If it does not, replace it with a new one.
3-1
X9DRFF-iG+/iTG+/7G+/7TG+ Motherboard User’s Manual
Losing the System’s Setup Configuration
1. Make sure that you are using a high quality power supply. A poor quality
power supply may cause the system to lose the CMOS setup information.
Refer to Section 2-7 for details on recommended power supplies.
2. The battery on your motherboard may be old. Check to verify that it still supplies ~3VDC. If it does not, replace it with a new one.
3. If the above steps do not fix the Setup Configuration problem, contact your
vendor for repairs.
When the System Becomes Unstable
A. The system becomes unstable during or after the OS installation
The system becomes unstable during or after the OS installation, check the following:
1. CPU/BIOS support: Make sure that your CPU is supported, and you have the
latest BIOS installed in your system.
2. Memory support: Make sure that the memory modules are supported by testing the modules using memtest86 or a similar utility.
Note: Refer to the product page on our website http:\\www.supermicro.
com for memory and CPU support and updates.
3. HDD support: Make sure that all hard disk drives (HDDs) work properly. Replace the bad HDDs with good ones.
4. System cooling: Check system cooling to make sure that all heatsink fans,
and CPU/system fans, etc., work properly. Check Hardware Monitoring settings in the BIOS to make sure that the CPU and System temperatures are
within the normal range. Also check the front panel Overheat LED, and make
sure that the Overheat LED is not on.
5. Adequate power supply: Make sure that the power supply provides adequate
power to the system. Make sure that all power connectors are connected.
Please refer to our website for more information on minimum power requirement.
6. Proper software support: Make sure that the correct drivers are used.
3-2
Chapter 3: Troubleshooting
B. The system becomes unstable before or during the OS installation
When the system becomes unstable before or during OS installation, check the
following:
1. Source of installation: Make sure that the devices used for installation are
working properly, including boot devices such as CD/DVD disc, CD/DVDROM.
2. Cable connection: Check to make sure that all cables are connected and
working properly.
3. Using minimum configuration for troubleshooting: Remove all unnecessary
components (starting with add-on cards first), and use minimum configuration (with a CPU and one memory module installed) to identify the trouble
areas. Refer to the steps listed in Section A above for proper troubleshooting
procedures.
4. Identifying bad components by isolating them: If necessary, remove a component in question from the chassis, and test it in isolation to make sure that it
works properly. Replace a bad component with a good one.
5. Check and change one component at a time instead of changing several
items at the same time. This will help isolate and identify the problem.
6. To find out if a component is good, swap this component with a new one to
see if the system will work properly. If so, then the old component is bad.
You can also install the component in question in another system. If the new
system works, the component is good and the old system has problems.
3-3
X9DRFF-iG+/iTG+/7G+/7TG+ Motherboard User’s Manual
3-2 Technical Support Procedures
Before contacting Technical Support, please take the following steps. Also, please
note that as a motherboard manufacturer, Supermicro also sells motherboards
through its channels, so it is best to first check with your distributor or reseller for
troubleshooting services. They should know of any possible problem(s) with the
specific system configuration that was sold to you.
1. Please go through the ‘Troubleshooting Procedures’ and 'Frequently Asked
Question' (FAQ) sections in this chapter or see the FAQs on our website
(http://www.supermicro.com/) before contacting Technical Support.
2. BIOS upgrades can be downloaded from our website (http://www.supermicro.
com).
3. If you still cannot resolve the problem, include the following information when
contacting Supermicro for technical support:
•Motherboard model and PCB revision number
•BIOS release date/version (This can be seen on the initial display when
your system first boots up.)
•System configuration
•An example of a Technical Support form is on our website at (http://www.
supermicro.com).
•Distributors: For immediate assistance, please have your account number
ready when placing a call to our technical support department. We can be
reached by e-mail at support@supermicro.com.
3-4
Chapter 3: Troubleshooting
3-3 Battery Removal and Installation
Battery Removal
To remove the onboard battery, follow the steps below:
1. Power off your system and unplug your power cable.
2. Locate the onboard battery as shown below.
3. Using a tool such as a pen or a small screwdriver, push the battery lock outwards to unlock it. Once unlocked, the battery will pop out from the holder.
4. Remove the battery.
Proper Battery Disposal
Warning: Please handle used batteries carefully. Do not damage the battery in any
way; a damaged battery may release hazardous materials into the environment. Do
not discard a used battery in the garbage or a public landfill. Please comply with the
regulations set up by your local hazardous waste management agency to dispose of
your used battery properly.
Battery Installation
1. To install an onboard battery, follow the steps 1 & 2 above and continue
below.
2. Identify the battery's polarity. The positive (+) side should be facing up.
3. Insert the battery into the battery holder and push it down until you hear a
click to ensure that the battery is securely locked.
Warning: When replacing a battery, be sure to only replace it with the same type.
OR
3-5
X9DRFF-iG+/iTG+/7G+/7TG+ Motherboard User’s Manual
3-4 Frequently Asked Questions
Question: What are the various types of memory that my motherboard can
support?
Answer: The motherboard supports Registered (RDIMM)/Load Reduced (LRDIMM)
ECC or Unbuffered (UDIMM) ECC/Non-ECC DDR3 modules. To enhance memory
performance, do not mix memory modules of different speeds, types, and sizes.
Please follow all memory installation instructions given on Section 2-4 in Chapter 2.
Question: How do I update my BIOS?
It is recommended that you do not upgrade your BIOS if you are not experiencing
any problems with your system. Updated BIOS files are located on our website
at http://www.supermicro.com. Please check our BIOS warning message and the
information on how to update your BIOS on our website. Select your motherboard
model and download the BIOS file to your computer. Also, check the current BIOS
revision to make sure that it is newer than your BIOS before downloading. You can
choose from the zip file and the .exe file. If you choose the zip BIOS file, please
unzip the BIOS file onto a bootable USB device. Run the batch file using the format
AMI.bat filename.rom from your bootable USB device to flash the BIOS.
Warning: Do not shut down or reset the system while updating the BIOS to prevent
possible system boot failure!
Note: The SPI BIOS chip used on this motherboard cannot be removed.
Send your motherboard back to our RMA Department at Supermicro for
repair. For BIOS Recovery instructions, please refer to the AMI BIOS
Recovery Instructions posted at http://www.supermicro.com.
Question: How do I handle the used battery?
Answer: Please handle used batteries carefully. Do not damage the battery in any
way; a damaged battery may release hazardous materials into the environment.
Do not discard a used battery in the garbage or a public landfill. Please comply
with the regulations set up by your local hazardous waste management agency to
dispose of your used battery properly. Refer to Section 3-3.
3-6
Chapter 3: Troubleshooting
3-5 Returning Merchandise for Service
A receipt or copy of your invoice marked with the date of purchase is required before
any warranty service will be rendered. You can obtain service by calling your vendor for a Returned Merchandise Authorization (RMA) number. When returning the
motherboard to the manufacturer, the RMA number should be prominently displayed
on the outside of the shipping carton, and the shipping package is mailed prepaid
or hand-carried. Shipping and handling charges will be applied for all orders that
must be mailed when service is complete. For faster service, you can also request
a RMA authorization online (http://www.supermicro.com/RmaForm/).
This warranty only covers normal consumer use and does not cover damages incurred in shipping or from failure due to the alternation, misuse, abuse or improper
maintenance of products.
During the warranty period, contact your distributor first for any product problems.
3-7
X9DRFF-iG+/iTG+/7G+/7TG+ Motherboard User’s Manual
Notes
3-8
Chapter 4: AMI BIOS
Chapter 4
BIOS
4-1 Introduction
This chapter describes the AMI BIOS Setup utility for the X9DRFF-iG+/
iTG+/7G+/7TG+. It also provides the instructions on how to navigate the AMI BIOS
Setup utility screens. The AMI ROM BIOS is stored in a Flash EEPROM and can
be easily updated.
Starting BIOS Setup Utility
To enter the AMI BIOS Setup utility screens, press the <Del> key while the system
is booting up.
Note: In most cases, the <Del> key is used to invoke the AMI BIOS setup
screen. There are a few cases when other keys are used, such as <F3>,
<F4>, etc.
Each main BIOS menu option is described in this manual. The Main BIOS setup
menu screen has two main frames. The left frame displays all the options that can
be configured. Grayed-out options cannot be configured. Options in blue can be
configured by the user. The right frame displays the key legend. Above the key
legend is an area reserved for informational text related to the option currently
selected in the left frame.
Note: The AMI BIOS has default informational messages built in. The
manufacturer retains the option to include, omit, or change any of these
informational messages.
The AMI BIOS Setup utility uses a key-based navigation system called "hot keys."
Most of the AMI BIOS setup utility "hot keys" can be used at any time during setup
navigation. These keys include <F3>, <F4>, <Enter>, <ESC>, arrow keys, etc.
Note 1: In this section, options printed in Bold are default settings.
Note 2: <F3> is used to load optimal default settings. <F4> is used to save
the settings and exit the setup utility.
4-1
X9DRFF-iG+/iTG+/7G+/7TG+ Motherboard User’s Manual
How To Change the Configuration Data
The configuration data that determines the system parameters may be changed by
entering the AMI BIOS Setup utility. This Setup utility can be accessed by pressing
<Delete> at the appropriate time during system boot.
Note: For AMI UEFI BIOS Recovery, please refer to the UEFI BIOS Recovery User Guide posted @http://www.supermicro.com/support/manuals/.
Starting the Setup Utility
Normally, the only visible Power-On Self-Test (POST) routine is the memory test.
As the memory is being tested, press the <Delete> key to enter the main menu of
the AMI BIOS Setup utility. From the main menu, you can access the other setup
screens. An AMI BIOS identification string is displayed at the left bottom corner of
the screen below the copyright message.
Warning: Do not upgrade the BIOS unless your system has a BIOS-related issue.
Flashing the wrong BIOS can cause irreparable damage to the system. In no event
shall the manufacturer be liable for direct, indirect, special, incidental, or consequential
damage arising from a BIOS update. If you have to update the BIOS, do not shut down
or reset the system while the BIOS is being updated to avoid possible boot failure.
4-2 Main Setup
When you first enter the AMI BIOS Setup utility, you will enter the Main setup screen.
You can always return to the Main setup screen by selecting the Main tab on the
top of the screen. The Main BIOS Setup screen is shown below.
4-2
Chapter 4: AMI BIOS
The AMI BIOS main menu displays the following information:
System Date
This item displays the system date in Day MM/DD/YY format (e.g. Sat 10/20/2012).
System Time
This item displays the system time in HH:MM:SS format (e.g. 15:32:52).
Supermicro X9DRFF-iG+/iTG+/7G+/7TG+
Version
This item displays the SMC version of the BIOS ROM used in this system.
Build Date
This item displays the date that the BIOS ROM was built.
Memory Information
Total Memory
This displays the amount of memory available in the system.
4-3
X9DRFF-iG+/iTG+/7G+/7TG+ Motherboard User’s Manual
4-3 Advanced Setup Configurations
Use the arrow keys to select the Advanced Setup submenu and press <Enter> to
access the following items.
Boot Feature
Quiet Boot
Use this item to select bootup screen display between POST messages and the
OEM logo. Select Disabled to display the POST messages. Select Enabled to
display the OEM logo instead of the normal POST messages. The options are
Enabled and Disabled.
AddOn ROM Display Mode
Use this item to set the AddOn Option ROM display mode. Select Keep Current to
use the current Option ROM display mode. Select Force BIOS to use the Option
ROM display mode set by the system BIOS. The options are Force BIOS and
Keep Current.
Bootup Num-Lock
Use this feature to set the Power-on state for the Num Lock key on the keyboard.
The options are Off and On.
Wait For 'F1' If Error
Select Enabled to force the system to wait until the 'F1' key is pressed if an error
occurs. The options are Disabled and Enabled.
4-4
Chapter 4: AMI BIOS
Interrupt 19 Capture
Interrupt 19 is the software interrupt that handles the boot disk function. When this
item is set to Enabled, the ROM BIOS of the host adaptors will "capture" Interrupt 19
at bootup and allow the drives that are attached to these host adaptors to function
as bootable disks. If this item is set to Disabled, the ROM BIOS of the host adaptors will not capture Interrupt 19, and the drives attached to these adaptors will not
function as bootable devices. The options are Enabled and Disabled.
Re-try Boot
When the feature is set to Enabled, the BIOS will continuously retry to boot from
the selected boot type. The options are Disabled, Legacy Boot, and EFI Boot.
Power Configuration
Watch Dog Function
If enabled, the Watch Dog timer will set the system to automatically reboot when
a non-recoverable error occurs, and this error lasts for more than five minutes.
The options are Enabled and Disabled.
Power Button Function
If this feature is set to Instant Off, the system will power off immediately as soon
as the user presses the power button. If this feature is set to 4 Seconds Override,
the system will power off when the user presses the power button for 4 seconds or
longer. The options are Instant Off and 4 Seconds Override.
Restore on AC Power Loss
Use this feature to set the power state after a power outage. Select Stay Off for the
system power to remain off after a power loss. Select Power On for the system
power to be turned on after a power loss. Select Last State to allow the system
to resume its last state before a power loss. The options are Power On, Stay Off,
and Last State.
CPU Configuration
This submenu displays CPU information as detected by the BIOS. It also allows
the user to configure CPU settings.
4-5
X9DRFF-iG+/iTG+/7G+/7TG+ Motherboard User’s Manual
Socket 1 CPU Information, Socket 2 CPU Information
This submenu displays the following information on the CPUs installed in Socket
1 and Socket 2.
•Type of CPU
•CPU Signature
•Microcode Patch
•CPU Stepping
•Maximum CPU Speed
•Minimum CPU Speed
•Processor Cores
•Intel HT (Hyper-Threading) Technology
•Intel VT-x Technology
•Intel SMX Technology
•L1 Data Cache
•L1 Code Cache
•L2 Cache
•L3 Cache
CPU Speed
This item displays the speed of the CPU installed in the Socket specified.
64-bit
This item indicates if 64-bit technology is supported by the CPU installed in the
Socket selected.
Clock Spread Spectrum
Select Enable to enable Clock Spectrum support, which will allow the BIOS to
monitor and attempt to reduce Electromagnetic Interference level caused by the
components whenever needed. The options are Disabled and Enabled.
4-6
Chapter 4: AMI BIOS
RTID (Record Types IDs)
This feature displays the total number of Record Type IDs for local and remote
pools. The options are Optimal and Alternate.
Hyper-threading
Select Enabled to support Intel Hyper-threading Technology to enhance CPU performance. The options are Enabled and Disabled.
Active Processor Cores
Set to Enabled to use the processor's second core and above. (Please refer to Intel's
website for more information.) The options are All, 1, 2, 4, and 6.
Limit CPUID Maximum
Use this feature to set the maximum CPU ID value. Enable this function to boot
legacy operating systems that do not support processors with extended CPUID
functions. The options are Enabled and Disabled (for the Windows OS).
Execute Disable Bit (Available if supported by the OS & the CPU)
Select Enabled to enable the Execute Disable Bit which will allow the processor
to designate areas in the system memory where an application code can execute
and where it cannot, thus preventing a worm or a virus from flooding illegal codes
to overwhelm the processor or damage the system during an attack. The default is
Enabled. (Refer to Intel and Microsoft Web sites for more information.)
Intel® AES-NI
Select Enable to use the Intel Advanced Encryption Standard (AES) New Instructions (NI) to ensure data security. The options are Enabled and Disabled.
MLC Streamer Prefetcher (Available when supported by the CPU)
If set to Enabled, the MLC (Mid-Level Cache) streamer prefetcher will prefetch
streams of data and instructions from the main memory to the L2 cache in the CPU
to improve CPU performance. The options are Disabled and Enabled.
MLC Spatial Prefetcher (Available when supported by the CPU)
If this feature is set to Disabled, the MLC spatial prefetcher will prefetch the cache
line for 64 bytes. If this feature is set to Enabled, the MLC spatial prefetcher will
prefetch both cache lines for 128 bytes as comprised. The options are Disabled
and Enabled.
DCU Streamer Prefetcher (Available when supported by the CPU)
If this item is set to Enabled, the Data Cache Unit (DCU) streamer prefetcher will
prefetch L1 data to speed up data accessing and processing to enhance CPU
performance. The options are Disabled and Enabled.
4-7
X9DRFF-iG+/iTG+/7G+/7TG+ Motherboard User’s Manual
DCU IP Prefetcher
Select Enabled for DCU (Data Cache Unit) IP Prefetcher support, which will prefetch
IP addresses to improve network connectivity and system performance. The options
are Enabled and Disabled.
Intel® Virtualization Technology (Available when supported by the CPU)
Select Enabled for Intel Virtualization Technology support, which will allow one
platform to run multiple operating systems and applications in independent partitions, creating multiple "virtual" systems in one physical computer. The options
are Enabled and Disabled.
Note: If there is any change to this setting, you will need to power off and
restart the system for the change to take effect. Please refer to Intel’s
website for detailed information.)
 CPU Power Management Configuration
This submenu allows the user to configure the following CPU Power Management
settings.
Power Technology
Select Energy Efficiency to support power-saving mode. Select Custom to customize system power settings. Select Disabled to disable power-saving settings.
The options are Disabled, Energy Efficient, and Custom. If the option is set to
Custom, the following items will display:
EIST (Available when Power Technology is set to Custom)
EIST (Enhanced Intel SpeedStep Technology) allows the system to automatically adjust processor voltage and core frequency to reduce power
consumption and heat dissipation. The options are Disabled and Enabled.
C1E Support (Available when Power Technology is set to Custom)
Select Enabled to enable Enhanced C1 Power State to boost system performance. The options are Enabled and Disabled.
CPU C3 Report (Available when Power Technology is set to Custom)
Select Enabled to allow the BIOS to report the CPU C3 State (ACPI C2) to
the operating system. During the CPU C3 State, the CPU clock generator
is turned off. The options are Enabled and Disabled.
4-8
Chapter 4: AMI BIOS
CPU C6 Report (Available when Power Technology is set to Custom)
Select Enabled to allow the BIOS to report the CPU C6 State (ACPI C3) to
the operating system. During the CPU C6 State, the power to all cache is
turned off. The options are Enabled and Disabled.
CPU C7 Report (Available when Power Technology is set to Custom)
Select Enabled to allow the BIOS to report the CPU C7 State (ACPI C3) to
the operating system. CPU C7 State is a processor-specific low C-State.
The options are Enabled and Disabled.
Package C-State limit (Available when Power Technology is set to
Custom)
Use this feature to set the limit on the C-State package register. The options
are C0, C2, C6, and No Limit.
Energy Performance Bias
Use this feature to select an appropriate fan setting to maximize system
performance (with maximum cooling) or to maximize energy efficiency
with maximum power saving). The fan speeds are controlled by firmware
management via IPMI 2.0. The options are Performance, Balanced Performance, Balanced Energy, and Energy Efficient.
Factory Long Duration Power Limit
This item displays the power limit (in watts) set by the manufacturer during
which long duration power is maintained.
Long Duration Power Limit
This item displays the power limit (in watts) set by the user during which
long duration power is maintained. The default setting is 0.
Factory Long Duration Maintained
This item displays the period of time (in seconds) set by the manufacturer
during which long duration power is maintained.
Long Duration Maintained
This item displays the period of time (in seconds) during which long duration
power is maintained. The default setting is 0.
Recommended Short Duration Power Limit
This item displays the short duration power settings (in watts) recommended
by the manufacturer.
4-9
X9DRFF-iG+/iTG+/7G+/7TG+ Motherboard User’s Manual
Short Duration Power Limit
This item displays the time period during which short duration power (in
watts)is maintained. The default setting is 0.
Chipset Configuration
North Bridge
This feature allows the user to configure the settings for the Intel North Bridge.
Integrated IO Configuration
Intel® VT-d
Select Enabled to enable Intel Virtualization Technology support for Direct I/O
VT-d by reporting the I/O device assignments to the VMM (Virtual Machine
Monitor) through the DMAR ACPI tables. This feature offers fully-protected I/O
-resource sharing across Intel platforms, providing greater reliability, security
and availability in networking and data-sharing. The options are Enabled and
Disabled.
Aging Timer Rollover
Use this feature to configure Aging Timer Rollover settings. Select Default to allow the BIOS to configure Aging Timer Roller settings. The options are Default,
Disabled, 32us, 128 us and 512 us.
Intel® I/OAT
Select Enabled to enable Intel I/OAT (I/O Acceleration Technology), which significantly reduces CPU overhead by leveraging CPU architectural demands, freeing
up the system resource for other tasks. The options are Disabled and Enabled.
DCA Support
Select Enabled to use Intel's DCA (Direct Cache Access) Technology to improve
data transfer efficiency. The default setting is Enabled.
MMCFG BASE
This feature determines the lowest base address that can be assigned to PCI
devices. The lower the address, the less system memory is available (for 32-bit
OS). The higher the address, the less resources are allocated to PCI devices.
The options are 0x80000000, 0xA0000000, and 0xC0000000.
4-10
Chapter 4: AMI BIOS
IIO 1 PCIe Port Bifurcation Control
This submenu configures the following IO PCIe Port Bifurcation Control settings
for the PCIe ports. It also determines how the available PCI-Express lanes are
distributed between the PCI-Exp. Root ports.
CPU 1 Slot J1 PCI-E 3.0 x16 Link Speed
Select GEN1 to enable PCI-Exp Generation 1 support for Slot J1. Select GEN2 to
enable PCI-Exp Generation 2 support for Slot J1. Select GEN3 to enable PCI-Exp
Generation 3 support for Slot J1. The options are GEN1, GEN2, and GEN3.
CPU 1 Slot J2 PCI-E 3.0 x8 Link Speed
Select GEN1 to enable PCI-Exp Generation 1 support for Slot J2. Select GEN2 to
enable PCI-Exp Generation 2 support for Slot J2. Select GEN3 to enable PCI-Exp
Generation 3 support for Slot J2. The options are GEN1, GEN2, and GEN3.
CPU 1 Slot J3 PCI-E 3.0 x8 Link Speed
Select GEN1 to enable PCI-Exp Generation 1 support for Slot J3. Select GEN2 to
enable PCI-Exp Generation 2 support for Slot J3. Select GEN3 to enable PCI-Exp
Generation 3 support for Slot J3. The options are GEN1, GEN2, and GEN3.
IIO 2 PCIe Port Bifurcation Control
This submenu configures the following IO PCIe Port Bifurcation Control settings
for the PCIe ports. It also determines how the available PCI-Express lanes are
distributed between the PCI-Exp. Root Ports.
CPU 2 Slot SXB1A PCI-E 3.0 x16 Link Speed
Select GEN1 to enable PCI-Exp Generation 1 support for Slot SXB1A. Select
GEN2 to enable PCI-Exp Generation 2 support for Slot SXB1A. Select GEN3 to
enable PCI-Exp Generation 3 support for Slot SXB1A. The options are GEN1,
GEN2, and GEN3.
CPU 2 Slot SXB1B PCI-E 3.0 x16 Link Speed
Select GEN1 to enable PCI-Exp Generation 1 support for Slot SXB1B. Select
GEN2 to enable PCI-Exp Generation 2 support for Slot SXB1B. Select GEN3 to
enable PCI-Exp Generation 3 support for Slot SXB1B. The options are GEN1,
GEN2, and GEN3.
QPI Configuration
Current QPI Link Speed
This item displays the current speed of the QPI Link.
4-11
X9DRFF-iG+/iTG+/7G+/7TG+ Motherboard User’s Manual
Current QPI Link Frequency
This item displays the frequency of the QPI Link.
Isoc
Select Enabled to enable Isochronous support to meet QoS (Quality of Service)
requirements. This feature is especially important for virtualization technology.
The options are Enabled and Disabled.
QPI (Quick Path Interconnect) Link Speed Mode
Use this feature to select data transfer speed for QPI Link connections. The
options are Fast and Slow.
QPI Link Frequency Select
Use this feature to select the desired QPI frequency. The options are Auto, 6.4
GT/s, 7.2 GT/s, and 8.0 GT/s.
DIMM Configuration
This section displays the following DIMM information.
Current Memory Mode
This item displays the current memory mode.
Current Memory Speed
This item displays the current memory speed.
Mirroring
This item displays if memory mirroring is supported by the motherboard. Memory
mirroring creates a duplicate copy of the data stored in the memory to enhance
data security.
Sparing
This item displays if memory sparing is supported by the motherboard. Memory
sparing enhances system performance.
DIMM Information
The submenu displays the status of a DIMM module detected by the BIOS.
CPU Socket 1 DIMM Information/CPU Socket 2 DIMM Information
Memory Mode
When Independent is selected, all DIMMs are available to the operating system.
When Mirroring is selected, the motherboard maintains two identical copies of all
4-12
Chapter 4: AMI BIOS
data in memory for data backup. When Lockstep is selected, the motherboard
uses two areas of memory to run the same set of operations in parallel. The
options are Independent, Mirroring, and Lockstep.
DRAM RAPL Mode
RAPL (Running Average Power Limit) provides mechanisms to enforce power
consumption limits on supported processors The options are DRAM RAPL
MODE0, DRAM RAPL MODE1, and Disabled.
DDR Speed
Use this feature to force a DDR3 memory module to run at a frequency other
than what is specified by the manufacturer. The options are Auto, Force DDR3800, Force DDR3-1066, Force DDR3-1333, Force DDR3-1600 and Force SPD.
Channel Interleaving
This feature selects from the different channel interleaving methods. The options
are Auto, 1 Way, 2 Way, 3, Way, and 4 Way.
Rank Interleaving
This feature allows the user to select a rank memory interleaving method. The
options are Auto, 1 Way, 2 Way, 4, Way, and 8 Way.
Patrol Scrub
Patrol Scrubbing is a process that allows the CPU to correct correctable memory
errors detected on a memory module and send the correction to the requestor
(the original source). When this item is set to Enabled, the IO hub will read and
write back one cache line every 16K cycles if there is no delay caused by internal
processing. By using this method, roughly 64 GB of memory behind the IO hub
will be scrubbed every day. The options are Enabled and Disabled.
Demand Scrub
Demand Scrubbing is a process that allows the CPU to correct correctable
memory errors found on a memory module. When the CPU or I/O issues a
demand-read command, and the read data from memory turns out to be a
correctable error, the error is corrected and sent to the requestor (the original
source). Memory is updated as well. Select Enabled to use Demand Scrubbing
for ECC memory correction. The options are Enabled and Disabled.
Data Scrambling
Select Enabled to enable data scrambling to ensure data security and integrity.
The options are Disabled and Enabled.
4-13
X9DRFF-iG+/iTG+/7G+/7TG+ Motherboard User’s Manual
Device Tagging
Select Enabled to support device tagging. The options are Disabled and Enabled.
Thermal Throttling
Throttling improves CPU reliability and reduces power consumption via automatic
voltage control during processor idle states. The options are Disabled and CLTT
(Closed Loop Thermal Throttling).
South Bridge Configuration
This feature displays PCH information and allows the user to configure PCH settings.
PCH Information
The following PCH information will be displayed.
•Name: This item displays the name of the PCH chip.
•Stepping: This item displays the PCH stepping.
•USB Devices: This item displays the USB devices detected by the BIOS.
All USB Devices
Select Enabled to enable all USB ports/devices. The options are Disabled and
Enabled.
EHCI Controller 1/EHCI Controller 2 (Available when All USB Devices is set
to Enabled)
Select Enabled to enable EHCI (Enhanced Host Controller Interface) Controller 1
or Controller 2. The options are Disabled and Enabled.
Legacy USB Support (Available when USB Functions is not Disabled)
Select Enabled to support legacy USB devices. Select Auto to disable legacy support if USB devices are not present. Select Disabled to have USB devices available
for EFI (Extensive Firmware Interface) applications only. The settings are Disabled,
Enabled and Auto.
Port 60/64 Emulation
Select Enabled to enable I/O port 60h/64h emulation support for the legacy USB
keyboard so that it can be fully supported by the operating systems that does not
recognize a USB device. The options are Disabled and Enabled.
4-14
Chapter 4: AMI BIOS
EHCI Hand-Off
This item is for operating systems that do not support Enhanced Host Controller
Interface (EHCI) hand-off. When this feature is enabled, EHCI ownership will be
changed by the EHCI driver. The options are Disabled and Enabled.
SATA Configuration
When this submenu is selected, the AMI BIOS automatically detects the presence
of IDE or SATA devices and displays the following items.
SATA Port0~SATA Port5: The AMI BIOS displays the status of each SATA port
as detected by the BIOS.
SATA Mode
Use this feature to configure SATA mode for a selected SATA port. The options are
Disabled, IDE Mode, AHCI Mode and RAID Mode. The following are displayed
depending on your selection:
IDE Mode
The following items are displayed when IDE Mode is selected:
Serial-ATA (SATA) Controller 0~1
Use this feature to activate or deactivate the SATA controller, and set the
compatibility mode. The options are Disabled, Enhanced, and Compatible.
The default for SATA Controller 0 is Compatible. The default of SATA Controller 1 is Enhanced.
AHCI Mode
The following items are displayed when the AHCI Mode is selected.
Aggressive Link Power Management
When Enabled, the SATA AHCI controller manages the power usage of the
components installed on the SATA link. The controller will put the link in a
low power mode during extended periods of I/O inactivity, and will return the
link to an active state when I/O activity resumes. The options are Enabled
and Disabled.
Port 0~5 Hot Plug
Select Enabled to enable hot-plug support for a particular port, which will
allow the user to change a hardware component or device without shutting
down the system. The options are Enabled and Disabled.
4-15
X9DRFF-iG+/iTG+/7G+/7TG+ Motherboard User’s Manual
Port 0~5 Staggered Spin-Up
Select Enabled to enable Staggered Spin-up support to prevent excessive
power consumption caused by multiple HDDs spinning-up simultaneously.
The options are Enabled and Disabled.
RAID Mode
The following items are displayed when RAID Mode is selected:
SATA RAID Option ROM/UEFI Driver
Use this feature to enable the onboard SATA Option ROM or EFI driver. The
options are Enabled and Disabled.
Port 0~5 Hot Plug
Select Enabled to enable hot-plug support for the particular port. The options
are Disabled and Enabled.
PCIe/PCI/PnP Configuration
Launch Storage Add-on Card OpROM Priority
Use this feature to select the Option ROM you want to use to boot the system when
there are multiple Option ROMs available in the system. The options are UEFI only
and Legacy only.
PCI Latency Timer
Use this feature to set the latency timer of each PCI device installed on a PCI bus.
Select 64 to set the PCI latency to 64 PCI clock cycles. The options are 32, 64,
96, 128, 160, 192, 224 and 248.
PERR# Generation
Select Enabled to allow a PCI device to generate a PERR number for a PCI Bus
Signal Error Event. The options are Enabled and Disabled.
SERR# Generation
Select Enabled to allow a PCI device to generate an SERR number for a PCI Bus
Signal Error Event. The options are Enabled and Disabled.
Maximum Payload
Select Auto to allow the system BIOS to automatically set the maximum payload
value for a PCI-E device to enhance system performance. The options are Auto,
128 Bytes and 256 Bytes, 512 Bytes, 1024 Bytes, 2048 Bytes, and 4096 Bytes.
4-16
Chapter 4: AMI BIOS
Maximum Read Request
Select Auto to allow the system BIOS to automatically set the maximum Read
Request size for a PCI-E device to enhance system performance. The options are
Auto, 128 Bytes, 256 Bytes, 512 Bytes, 1024 Bytes, 2048 Bytes, and 4096 Bytes.
ASPM Support
Use this feature to set the Active State Power Management (ASPM) level for a
PCI-E device. Select Auto to allow the system BIOS to automatically set the ASPM
level for the system. Select Disabled to disable ASPM support. The options are
Disabled, and Auto.
Warning: Enabling ASPM support may cause some PCI-E devices to fail!
Above 4G Decoding (Available if the system supports 64-bit PCI decoding)
Select Enabled to decode a PCI device that supports 64-bit in the space above 4G
Address. The options are Enabled and Disabled.
CPU1 Slot J1 PCI-E 3.0 x16 OPROM
Select Enabled to enable Option ROM support to boot the computer using a device installed on the slot specified above. The options are Enabled and Disabled.
CPU1 Slot J2/Slot J3 PCI-E 3.0 x8 OPROM
Select Enabled to enable Option ROM support to boot the computer using a device installed on the slot specified above. The options are Enabled and Disabled.
PCH Slot J4 PCI-E 2.0 x4 OPROM
Select Enabled to enable Option ROM support to boot the computer using a device installed on the slot specified above. The options are Enabled and Disabled.
CPU2 Slot SXB1A/Slot SXB1B PCI-E 3.0 x16 OPROM
Select Enabled to enable Option ROM support to boot the computer using a device installed on the slot specified above. The options are Enabled and Disabled.
Onboard LAN Option ROM Select
Select iSCSI to use the iSCSI Option ROM to boot the computer using a network
device. Select PXE (Preboot Execution Environment) to use an PXE Option ROM to
boot the computer using a network device. The options are PXE, iSCSI and FCoE.
Load Onboard LAN1 Option ROM/Load Onboard LAN2 Option ROM
Select Enabled to enable the onboard LAN1 or LAN2 Option ROM. This is to boot
the computer using a network device. The default setting for LAN1 Option ROM is
Enabled, and for LAN2 Option ROM is Disabled.
4-17
X9DRFF-iG+/iTG+/7G+/7TG+ Motherboard User’s Manual
Load Onboard SAS OPROM
Select Enabled for onboard SAS Option ROM support. This is to boot the computer
using a SAS device. The options are Disabled and Enabled.
VGA Priority
This feature allows the user to select the graphics adapter to be used as the primary
boot device. The options are Onboard, and Offboard.
Network Stack
Select Enabled enable PXE (Preboot Execution Environment) or UEFI (Unified
Extensible Firmware Interface) for network stack support. The options are Enabled
and Disabled.
IPv4 PXE Support (Available when Network Stack is set to Enabled)
Set this item to Enabled to activate IPv4 PXE Support. The options are Enabled
and Disabled.
IPv6 PXE Support (Available when Network Stack is set to Enabled)
Set this item to Enabled to activate IPv6 PXE Support. The options are Enabled
and Disabled.
Serial Port Console Redirection
COM 1/SOL
These two submenus allow the user to configure the following Console Redirection
settings for a COM port specified by the user.
COM1/SOL (Serial Over LAN) Console Redirection
Select Enabled to use COM1 or SOL (Serial_Over_LAN) port selected by the user
for Console Redirection. The options are Enabled and Disabled. The default setting
for COM1 is Disabled, and for SOL is Enabled.
Console Redirection Settings
Use this feature to specify how the host computer will communicate with the client
computer, which is the remote computer used by the user.
Terminal Type
This feature allows the user to select the target terminal emulation type for Console Redirection. Select VT100 to use the ASCII Character set. Select VT100+ to
add color and function key support. Select ANSI to use the Extended ASCII Char-
4-18
Chapter 4: AMI BIOS
acter Set. Select VT-UTF8 to use UTF8 encoding to map Unicode characters
into one or more bytes. The options are ANSI, VT100, VT100+, and VT-UTF8.
Bits Per second
Use this feature to set the transmission speed for a serial port used in Console
Redirection. Make sure that the same speed is used in the host computer and the
client computer. A lower transmission speed may be required for long and busy
lines. The options are 9600, 19200, 38400, 57600 and 115200 (bits per second).
Data Bits
Use this feature to set the data transmission size for Console Redirection. The
options are 7 Bits and 8 Bits.
Parity
A parity bit can be sent along with regular data bits to detect data transmission
errors. Select Even if the parity bit is set to 0, and the number of 1's in data bits
is even. Select Odd if the parity bit is set to 0, and the number of 1's in data bits
is odd. Select None if you do not want to send a parity bit with your data bits
in transmission. Select Mark to add a mark as a parity bit to be sent along with
the data bits. Select Space to add a Space as a parity bit to be sent with your
data bits. The options are None, Even, Odd, Mark and Space.
Stop Bits
A stop bit indicates the end of a serial data packet. Select 1 Stop Bit for standard
serial data communication. Select 2 Stop Bits if slower devices are used. The
options are 1 and 2.
Flow Control
Use this feature to set the flow control for Console Redirection to prevent data
loss caused by buffer overflow. Send a "Stop" signal to stop sending data when
the receiving buffer is full. Send a "Start" signal to start sending data when the
receiving buffer is empty. The options are None and Hardware RTS/CTS.
VT-UTF8 Combo Key Support
Select Enabled to enable VT-UTF8 Combination Key support for ANSI/VT100
terminals. The options are Enabled and Disabled.
Recorder Mode
Select Enabled to capture the data displayed on a terminal and send it as text
messages to a remote server. The options are Disabled and Enabled.
4-19
X9DRFF-iG+/iTG+/7G+/7TG+ Motherboard User’s Manual
Resolution 100x31
Select Enabled for extended-terminal resolution support. The options are Disabled and Enabled.
Legacy OS Redirection Resolution
Use this feature to select the number of rows and columns used in Console
Redirection for legacy OS support. The options are 80x24 and 80x25.
Putty KeyPad
This feature selects Function Keys and KeyPad settings for Putty, which is a
terminal emulator designed for the Windows OS. The options are VT100, LINUX,
XTERMR6, SCO, ESCN, and VT400.
Redirection After BIOS Post
Use this feature to enable or disable Legacy Console Redirection after BIOS
POST (Power On Self Test). When this feature is set to Bootloader, Legacy
Console Redirection is disabled before booting the OS. When this feature is
set to Always Enable, Legacy Console Redirection remains enabled during OS
bootup. The options are Always Enable and Bootloader.
Serial Port for Out-of-Band Management/Windows Emergency Management
Services (EMS)
The submenu allows the user to configure Console Redirection settings to support
Out-of-Band Serial Port management.
EMS Console Redirection
Select Enabled to select a COM Port for Console Redirection. The options are
Enabled and Disabled.
Console
Redirection Settings (for EMS)
This feature allows the user to specify how the host computer will exchange
data with the client computer, which is the remote computer used by the user.
Out-of-Band Management Port
The feature selects a serial port used by the Microsoft Windows Emergency
Management Services (EMS) to communicate with a remote server. The options
are COM1 and SOL.
Terminal Type
Use this feature to select the target terminal emulation type for Console Redirection. Select VT100 to use the ASCII character set. Select VT100+ to add color
4-20
Chapter 4: AMI BIOS
and function key support. Select ANSI to use the extended ASCII character set.
Select VT-UTF8 to use UTF8 encoding to map Unicode characters into one or
more bytes. The options are ANSI, VT100, VT100+, and VT-UTF8.
Bits Per Second
This item sets the transmission speed for a serial port used in Console Redirection. Make sure that the same speed is used in the host computer and the client
computer. A lower transmission speed may be required for long and busy lines.
The options are 9600, 19200, 57600, and 115200 (bits per second).
Flow Control
Use this feature to set the flow control for Console Redirection to prevent data
loss caused by buffer overflow. Send a Stop signal to stop sending data when
the receiving buffer is full. Send a Start signal to start sending data when the
receiving buffer is empty. The options are None, Hardware RTS/CTS, and
Software Xon/Xoff.
Data Bits, Parity, Stop Bits
The setting for each of these items is displayed.
ACPI Settings
Use this feature to configure Advanced Configuration and Power Interface (ACPI)
power management settings for your system.
ACPI Sleep State
Use this feature to select the ACPI State when the system is in sleep mode. Select
S1 (CPU Stop Clock) to erase all CPU caches and stop executing instructions. In
this setting, power to the CPU(s) and RAM is maintained, but RAM is refreshed.
Select Suspend Disabled to use power-reduced mode. Power will only be supplied
to limited components (such as RAMs) to maintain the most critical functions of the
system. The options are S1 (CPU Stop Clock), and Suspend Disabled.
NUMA (NON-Uniform Memory Access)
Select Enabled to enable the Non-Uniform Memory Access ACPI support. The options are Enabled and Disabled.
High Precision Event Timer
Select Enabled to activate the High Precision Event Timer (HPET) that produces
periodic interrupts at a much higher frequency than a Real-time Clock (RTC) does
in synchronizing multimedia streams, providing smooth playback, reducing the dependency on other timestamp calculation devices, such as an x86 RDTSC Instruc-
4-21
X9DRFF-iG+/iTG+/7G+/7TG+ Motherboard User’s Manual
tion embedded in the CPU. The High Performance Event Timer is used to replace
the 8254 Programmable Interval Timer. The options are Enabled and Disabled.
Trusted Computing (Available when a TPM device is detected
by the BIOS)
Configuration
TPM Support
When this feature is set to Enabled, and the onboard TPM is also set to Enabled,
you can use TPM support to improve data integrity and network security for your
system. The options are Enabled and Disabled.
TPM State
Select Enabled to enable TPM security settings to improve data integrity and
network security. The options are Disabled and Enabled.
Pending Operation
Use this item to schedule an operation for the security device. The options are
None, Enable Take Ownership, Disable Take Ownership, and TPM Clear.
Note: Upon system reset, the computer will reboot in order to execute the
pending operation and change the state of the security device.
Current Status Information: This item displays current TPM status.
TPM Enable Status
This item indicates if TPM is currently enabled or disabled.
TPM Active Status
This item indicates if TPM is currently active or not.
TPM Owner Status
This item displays the status of TPM Ownership.
ME Subsystem
Intel ME Subsystem Configuration
This feature displays information on the Intel Management Engine subsystem:
•ME BIOS Interface Version
4-22
Chapter 4: AMI BIOS
•ME Version
4-4 Event Logs
This submenu allows the user to configure Event Log settings.
Change SMBIOS Event Log Settings
This feature allows the user to configure SMBIOS Event settings.
Enabling/Disabling Options
SMBIOS Event Log
Select Enabled to enable SMBIOS (System Management BIOS) event logging during system boot. The options are Enabled and Disabled.
Runtime Error Logging Support
Select Enabled to support runtime error logging. The options are Enabled and
Disabled.
Memory Correctable Error Threshold
Use this feature to enter the threshold value for correctable memory errors. The
default setting is 10.
PCI Error Logging Support
Select Enabled to support error event logging for PCI slots. The options are Enabled
and Disabled.
4-23
X9DRFF-iG+/iTG+/7G+/7TG+ Motherboard User’s Manual
Erasing Settings
Erase Event Log
Select Enabled to erase the SMBIOS (System Management BIOS) Event Log, which
is completed before an event logging is initialized upon system reboot. The options
are No, Yes, next reset, and Yes, every reset.
When Log is Full
Select Erase Immediately to immediately erase SMBIOS error event logs that exceed the limit when the SMBIOS event log is full. Select Do Nothing for the system
to do nothing when the SMBIOS event log is full. The options are Do Nothing and
Erase Immediately.
SMBIOS Event Log Standard Settings
Log System Boot Event
Select Enabled to log system boot events. The options are Disabled and Enabled.
MECI (Multiple Event Count Increment)
Enter the increment value for the multiple event counter. Enter a number between
1 to 255. The default setting is 1.
METW (Multiple Event Count Time Window)
This item allows the user to decide how long (in minutes) should the multiple event
counter wait before generating a new event log. Enter a number between 0 to 99.
The default setting is 60.
View SMBIOS Event Log
This item displays SMBIOS envent log.
4-24
Chapter 4: AMI BIOS
4-5 IPMI
Use this feature to configure Intelligent Platform Management Interface (IPMI)
settings.
IPMI Firmware Revision
This item indicates the IPMI firmware revision used in your system.
IPMI Status
This item indicates the status of the IPMI firmware installed in your system.
System Event Log
Enabling/Disabling Options
SEL Components
Select Enabled for all system event logging at bootup. The options are Enabled
and Disabled.
Erasing Settings
Erase SEL
Select Yes, On next reset to erase all system event logs upon next system reboot.
Select Yes, On every reset to erase all system event logs upon each system reboot.
Select No to keep all system event logs after each system reboot. The options are
No, Yes, On next reset, and Yes, On every reset.
4-25
X9DRFF-iG+/iTG+/7G+/7TG+ Motherboard User’s Manual
When SEL is Full
This feature allows the user to decide what the BIOS should do when the system
event log is full. Select Erase Immediately to erase all events in the log when the
system event log is full. The options are Do Nothing and Erase Immediately.
BMC Network Configuration
LAN Channel 1: This feature is used to configure the settings for LAN1 Port.
IPMI LAN Selection: This item displays the current IPMI Selection setting.
IPMI Network Line Status: This item displays the status of the current IPMI
network connection line.
Update IPMI LAN Configuration
This feature allows the BIOS to implement any IP/MAC address changes at the next
system boot. If the option is set to Yes, any changes made to the settings below will
take effect at the next system reboot. The options are No and Yes.
Configuration Address Source
Use this feature to select the source of the IP address for this computer. If Static is
selected, you will need to know the IP address of this computer and enter it to the
system manually in the field. If DHCP is selected, the BIOS will search for a DHCP
(Dynamic Host Configuration Protocol) server in the network that it is attached to
and request the next available IP address for this computer. The options for are
DHCP and Static. The following items are assigned IP addresses automatically if
DHCP is selected, or can be configured manually if Static is selected.
Station IP Address
This item displays the Station IP address for this computer. This should be in decimal
and in dotted quad form (i.e., 192.168.10.253).
Subnet Mask
This item displays the sub-network that this computer belongs to. The value of each
three-digit number separated by dots should not exceed 255.
Station MAC Address
This item displays the Station MAC address for this computer. Mac addresses are
6 two-digit hexadecimal numbers.
Gateway IP Address
This item displays the Gateway IP address for this computer. This should be in
decimal and in dotted quad form (i.e., 192.168.10.253).
4-26
Chapter 4: AMI BIOS
4-6 Boot
This submenu allows the user to configure the following boot settings for the
system.
Set Boot Priority
1st Boot Device, 2nd Boot Device, 3rd Boot Device, etc.
Use these items to specify the sequence of boot device priority.
Delete Boot Option
Use this feature to select a boot device to delete from the boot priority list.
Delete Boot Option
Use this feature to select a boot device to delete.
Hard Disk Drive BBS Priorities
This item is used to select the boot device priority sequence from available hard
drives.
Network Device BBS Priorities
This item is used to select the boot device priority sequence from available network
devices.
UEFI Boot Drive BBS Priorities
This item is used to select the boot device priority sequence from available UEFI
devices.
4-27
X9DRFF-iG+/iTG+/7G+/7TG+ Motherboard User’s Manual
4-7 Security
This menu is used to configure the following security settings for the system.
Password Check
This feature determines when a password entry is required. If Setup is selected,
the user is required to enter a password upon entering the BIOS setup utility. If
Always is selected, the user is required to enter a password upon entering the
BIOS setup utility and upon each system boot. The options are Setup and Always.
Administrator Password
Use this item to set the Administrator Password which is required to enter the
BIOS setup utility. The length of the password should be from 3 characters to 20
characters long.
4-28
Chapter 4: AMI BIOS
4-8 Save & Exit
This submenu allows the user to configure the Save and Exit settings for the
system.
Discard Changes and Exit
Select this option to quit the BIOS Setup without making any permanent changes
to the system configuration, and reboot the computer. Select Discard Changes
and Exit, and press <Enter>. When the dialog box appears, asking you if you want
to exit the BIOS setup without saving, select Yes to quit BIOS without saving the
changes, or select No to quit the BIOS and save changes.
Save Changes and Reset
When you have completed the system configuration changes, select this option to
save the changes and reboot the computer so that the new system configuration
settings can take effect. Select Save Changes and Exit, and press <Enter>. When
the dialog box appears, asking you if you want to exit the BIOS setup without saving, select Yes to quit BIOS without saving the changes, or select No to quit the
BIOS and save changes.
Save Options
Save Changes
Select this option and press <Enter> to save all changes you've done so far and
return to the AMI BIOS utility. When the dialog box appears, asking you if you want
to save configuration, select Yes to save the changes, or select No to return to the
BIOS without making changes.
4-29
X9DRFF-iG+/iTG+/7G+/7TG+ Motherboard User’s Manual
Discard Changes
Select this feature and press <Enter> to discard all the changes and return to the
BIOS setup. When the dialog box appears, asking you if you want to load previous values, select Yes to load the values previous saved, or select No to keep the
changes you've made so far.
Restore Optimized Defaults
Select this feature and press <Enter> to load the optimized default settings that will
help optimize system performance. When the dialog box appears, asking you if you
want to load optimized defaults, select Yes to load the optimized default settings,
or select No to abandon optimized defaults.
Save as User Defaults
Select this feature and press <Enter> to save the current settings as the user's
defaults. When the dialog box appears, asking you if you want to save values as
user's defaults, click Yes to save the current values as user's default settings, or
click No to keep the defaults previously saved as the user's defaults.
Restore User Defaults
Select this feature and press <Enter> to load the user's defaults previously saved in
the system. When the dialog box appears, asking you if you want to restore user's
defaults, select Yes to restore the user's defaults previously saved in the system,
or select No to abandon the user's defaults that were previously saved.
Boot Override
Use this item to override the boot device priority sequence as listed in the Boot
submenu, and select one of the devices listed below to boot the system instead.
This is a one-time override.
#8100 ID0A LUN0 SEAGAGE ST9734,
#8100 ID43 LUN0 LSI LSI Logica,
#8100 ID0B LUN0 SEAGAGE ST9146,
IBA XE Slot 0100 v2208,
UEFI Built-in EFI Shell
4-30
Appendix A: BIOS POST Error Codes
Appendix A
BIOS Error Beep Codes
BIOS Error Beep Codes are not available for this motherboard.
A-1
X9DRFF-iG+/iTG+/7G+/7TG+ Motherboard User’s Manual
Notes
A-2
Appendix B: Software Installation Instructions
Appendix B
Software Installation Instructions
B-1 Installing Software Programs
The Supermicro ftp site contains drivers and utilities for your system at ftp://ftp.
supermicro.com. Some of these must be installed, such as the chipset driver.
After accessing the ftp site, go into the CDR_Images directory and locate the ISO
file for your motherboard. Download this file to create a CD/DVD of the drivers and
utilities it contains. (You may also use a utility to extract the ISO file if preferred.)
Another option is to go to the Supermicro Website at http://www.supermicro.com/
products/. Find the product page for your motherboard here, where you may download individual drivers and utilities.
After creating a CD/DVD with the ISO files, insert the disk into the CD/DVD drive
on your system and the display shown below should appear.
Driver/Tool Installation Display Screen
Note 1: Click the icons showing a hand writing on paper to view the
readme files for each item. Click the computer icons to the right of these
items to install each item (from top to the bottom) one at a time. After
installing each item, you must re-boot the system before moving on
to the next item on the list. The bottom icon with a CD on it allows you
to view the entire contents.
B-1
X9DRFF-iG+/iTG+/7G+/7TG+ Motherboard User’s Manual
Note 2: When making a storage driver diskette by booting into a Driver
CD, please set the SATA Configuration to "Compatible Mode" and configure
SATA as IDE in the BIOS Setup. After making the driver diskette, be sure
to change the SATA settings back to your original settings.
Note 3: Changing BMC log-in information is recommended during initial
system power-on. The default username is ADMIN and password is ADMIN. For BMC best practices, please refer to: http://www.supermicro.com/
products/nfo/files/IPMI/Best_Practices_BMC_Security.pdf
B-2 Configuring SuperDoctor III
The SuperDoctor® III program is a web-based management tool that supports
remote management capability. It includes Remote and Local Management tools.
The local management is called SD III Client. The SuperDoctor III program allows
you to monitor the environment and operations of your system. SuperDoctor III
displays crucial system information such as CPU temperature, system voltages
and fan status. See the figures below for examples of the SuperDoctor III interface.
Note: The default User Name and Password for SuperDoctor III is ADMIN
/ ADMIN.
Note: When SuperDoctor III is first installed, it adopts the temperature
threshold settings that have been set in BIOS. Any subsequent changes to
these thresholds must be made within SuperDoctor III, as the SuperDoctor III settings override the BIOS settings. To set the BIOS temperature
threshold settings again, you would first need to uninstall SuperDoctor III.
SuperDoctor® III Interface Display Screen (Health Information)
B-2
Appendix B: Software Installation Instructions
SuperDoctor® III Interface Display Screen (Remote Control)
Note: SD III Software Revision 1.0 can be downloaded from our Web
Site at: ftp://ftp.supermicro.com/utility/Super_Doctor_III/. You can also
download the SDIII User's Guide at: <http://www.supermicro.com/PRODUCT/Manuals/SDIII/UserGuide.pdf>. For Linux, we will recommend using
SuperDoctor II.
B-3
X9DRFF-iG+/iTG+/7G+/7TG+ Motherboard User’s Manual
Notes
B-4
(Disclaimer Continued)
The products sold by Supermicro are not intended for and will not be used in life support systems, medical equipment, nuclear facilities or systems, aircraft, aircraft devices,
aircraft/emergency communication devices or other critical systems whose failure to perform be reasonably expected to result in significant injury or loss of life or catastrophic
property damage. Accordingly, Supermicro disclaims any and all liability, and should buyer use or sell such products for use in such ultra-hazardous applications, it does so
entirely at its own risk. Furthermore, buyer agrees to fully indemnify, defend and hold Supermicro harmless for and against any and all claims, demands, actions, litigation, and
proceedings of any kind arising out of or related to such ultra-hazardous use or sale.
Download PDF