Intel® Server Board S3420GP
Technical Product Specification
Intel order number E65697-010
Revision 2.4
January, 2011
Enterprise Platforms and Services Division - Marketing
Revision History
Intel® Server Board S3420GP TPS
Revision History
Date
Feb. 2009
Revision
Number
0.3
Initial release.
May 2009
July. 2009
0.5
0.9
Update block diagram.
Updated POST error code and diagram.
Aug. 2009
1.0
Updated MTBF.
Nov. 2009
1.1
Additional details for memory configuration.
Dec. 2009
1.2
Added Intel Server Board S3420GPV details.
Dec. 2009
Jan. 2010
2.0
2.1
Updated processor name.
Corrected the typo.
Apr. 2010
2.2
Corrected the typo, updated processor name and remove CCC certification
marking information.
July. 2010
2.3
Corrected the typo.
Jan.2011
2.4



ii
Modifications
®
Corrected the typo. Added RDIMM support on S3420GPV.
Updated Table 45.
Add USB device readiness beep code information.
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS
Disclaimers
Disclaimers
Information in this document is provided in connection with Intel® products. No license, express
or implied, by estoppel or otherwise, to any intellectual property rights is granted by this
document. Except as provided in Intel's Terms and Conditions of Sale for such products, Intel
assumes no liability whatsoever, and Intel disclaims any express or implied warranty, relating to
sale and/or use of Intel products including liability or warranties relating to fitness for a particular
purpose, merchantability, or infringement of any patent, copyright or other intellectual property
right. Intel products are not intended for use in medical, life saving, or life sustaining applications.
Intel may make changes to specifications and product descriptions at any time, without notice.
Designers must not rely on the absence or characteristics of any features or instructions marked
"reserved" or "undefined." Intel reserves these for future definition and shall have no
responsibility whatsoever for conflicts or incompatibilities arising from future changes to them.
The Intel® Server Board S3420GP may contain design defects or errors known as errata which
may cause the product to deviate from published specifications. Current characterized errata
are available on request.
Intel Corporation server boards contain a number of high-density VLSI and power delivery
components that need adequate airflow to cool. Intel’s own chassis are designed and tested to
meet the intended thermal requirements of these components when the fully integrated system
is used together. It is the responsibility of the system integrator that chooses not to use Intel
developed server building blocks to consult vendor datasheets and operating parameters to
determine the amount of airflow required for their specific application and environmental
conditions. Intel Corporation cannot be held responsible if components fail or the server board
does not operate correctly when used outside any of their published operating or non-operating
limits.
Intel, Pentium, Itanium, and Xeon are trademarks or registered trademarks of Intel Corporation.
*Other brands and names may be claimed as the property of others.
Copyright © 2011 Intel Corporation
.
Revision 2.4
Intel order number E65697-010
iii
Table of Contents
Intel® Server Board S3420GP TPS
Table of Contents
1. Introduction ............................................................................................................................ 1 1.1 Chapter Outline ......................................................................................................... 1 1.2 Server Board Use Disclaimer .................................................................................... 1 2. Overview ................................................................................................................................. 2 2.1 Intel® Server Board S3420GP Feature Set............................................................... 2 2.2 Server Board Layout ................................................................................................. 5 2.2.1 Server Board Connector and Component Layout .................................................... 6 2.2.2 Intel® Server Board S3420GP Mechanical Drawings ............................................... 8 2.2.3 Server Board Rear I/O Layout ................................................................................ 14 3. Functional Architecture ....................................................................................................... 15 3.1 Processor Sub-System ........................................................................................... 17 3.1.1 Intel® Xeon® Processor 3400 Series ....................................................................... 17 3.1.2 Intel® CoreTM Processor i3-500 Series and Intel® Pentium® Processor G6950...... 17 3.1.3 Intel® Turbo Boost Technology ............................................................................... 17 3.1.4 Simultaneous Multithreading (SMT) ....................................................................... 18 3.1.5 Enhanced Intel SpeedStep® Technology................................................................ 18 3.2 Memory Subsystem................................................................................................. 18 3.2.1 Memory Sizing and Configuration ........................................................................... 18 3.2.2 Post Error Codes ..................................................................................................... 19 3.2.3 Publishing System Memory .................................................................................... 20 3.2.4 Memory Map and Population Rules ........................................................................ 21 3.3 Intel® 3420 Chipset PCH ......................................................................................... 24 3.4 I/O Sub-system ........................................................................................................ 25 3.4.1 PCI Express Interface ............................................................................................. 25 3.4.2 Serial ATA Support.................................................................................................. 26 3.4.3 USB 2.0 Support ..................................................................................................... 26 3.5 Optional Intel® SAS Entry RAID Module AXX4SASMOD....................................... 27 3.6 Integrated Baseboard Management Controller ...................................................... 27 3.6.1 Integrated BMC Embedded LAN Channel .............................................................. 29 3.6.2 Optional RMM3 Advanced Management Board ..................................................... 29 3.6.3 Serial Ports .............................................................................................................. 30 3.6.4 Floppy Disk Controller ............................................................................................. 30 3.6.5 Keyboard and Mouse Support ................................................................................ 30 3.6.6 Wake-up Control ..................................................................................................... 31 3.7 Video Support .......................................................................................................... 31 3.7.1 Intel® Server Board S3420GPLX and Intel® Server Board S3420GPLC ............... 31 3.7.2 Video for Intel® Server Board S3420GPV............................................................... 32 3.8 Network Interface Controller (NIC) ......................................................................... 33 3.8.1 GigE Controller 82574L ........................................................................................... 33 iv
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS
Table of Contents
3.8.2 GigE PHY 82578DM ............................................................................................... 33 3.8.3 MAC Address Definition .......................................................................................... 33 3.9 Intel® I/O Acceleration Technology 2 (Intel® I/OAT2) ............................................. 34 3.9.1 Direct Cache Access (DCA) .................................................................................... 34 3.10 Intel® Virtualization Technology for Directed I/O (Intel® VT-d) ................................ 34 4. Platform Management ......................................................................................................... 35 4.1 Feature Support ...................................................................................................... 35 4.1.1 IPMI 2.0 Features .................................................................................................... 35 4.1.2 Non-IPMI Features .................................................................................................. 36 4.2 Optional Advanced Management Feature Support ................................................ 37 4.2.1 Enabling Advanced Management Features ........................................................... 37 4.2.2 Keyboard, Video, Mouse (KVM) Redirection .......................................................... 37 4.2.3 Media Redirection ................................................................................................... 38 4.2.4 Web Services for Management (WS-MAN) ............................................................ 38 4.2.5 Local Directory Authentication Protocol (LDAP) ..................................................... 39 4.2.6 Embedded Webserver ............................................................................................ 39 4.3 Management Engine (ME) ...................................................................................... 39 5. Server Management Capability for Intel® Server Board S3420GPV .............................. 40 5.1 Super I/O ................................................................................................................. 40 5.1.1 Key Features of Super I/O ...................................................................................... 40 5.1.2 Sensor and Hardware Monitor ................................................................................ 40 5.1.3 Fan controller (Manual) ........................................................................................... 42 5.1.4 Voltage and Temperature Status Screen ............................................................... 44 5.2 SMBIOS ................................................................................................................... 45 5.2.1 Data Storage ........................................................................................................... 45 5.3 Event log and Viewer .............................................................................................. 45 5.3.1 Event Log Viewer in Setup ...................................................................................... 45 6. BIOS User Interface ............................................................................................................. 47 6.1 Logo/Diagnostic Screen .......................................................................................... 47 6.2 BIOS Boot Popup Menu .......................................................................................... 47 6.3 BIOS Setup utility .................................................................................................... 47 6.3.1 Operation ................................................................................................................. 48 6.3.2 Server Platform Setup Utility Screens .................................................................... 50 6.4 Loading BIOS Defaults ............................................................................................ 74 7. Connector/Header Locations and Pin-outs ...................................................................... 76 7.1 Board Connector Information .................................................................................. 76 7.2 Power Connectors ................................................................................................... 76 7.3 System Management Headers ............................................................................... 77 7.3.1 Intel® Remote Management Module 3 (Intel® RMM3) Connector .......................... 77 7.3.2 LCP/IPMB Header ................................................................................................... 78 7.3.3 HSBP Header .......................................................................................................... 78 Revision 2.4
Intel order number E65697-010
v
Table of Contents
Intel® Server Board S3420GP TPS
7.3.4 SGPIO Header ........................................................................................................ 79 7.4 Front Control Panel Connector ............................................................................... 79 7.4.1 Power Button ........................................................................................................... 80 7.4.2 Reset Button ............................................................................................................ 80 7.4.3 NMI Button............................................................................................................... 80 7.4.4 System Status Indicator LED .................................................................................. 80 7.5 I/O Connectors ........................................................................................................ 81 7.5.1 VGA Connector ....................................................................................................... 81 7.5.2 Rear NIC and USB connector ................................................................................. 82 7.5.3 SATA ....................................................................................................................... 83 7.5.4 50-pin PCI Express* Connector .............................................................................. 83 7.5.5 Serial Port Connectors ............................................................................................ 84 7.5.6 USB Connector ....................................................................................................... 84 7.6 PCI Express* Slot/PCI Slot/Riser Card Slot / ......................................................... 85 7.7 Fan Headers ............................................................................................................ 90 8. Jumper Blocks...................................................................................................................... 91 8.1 CMOS Clear and Password Reset Usage Procedure ............................................ 92 8.1.1 Clearing the CMOS ................................................................................................. 92 8.1.2 Clearing the Password ............................................................................................ 92 8.2 Integrated BMC Force Update Procedure (only for the Intel® Server Board
S3420GPLX and S3420GPLC) ................................................................................................. 93 8.3 ME Force Update Jumper ....................................................................................... 93 8.4 BIOS Recovery Jumper .......................................................................................... 94 ®
9. Intel Light Guided Diagnostics ......................................................................................... 95 9.1 System Status LED (For the Intel® Server Board S3420GPLX and S3420GPLC) 95 9.2 Post Code Diagnostic LEDs .................................................................................... 96 10. Design and Environmental Specifications ........................................................................ 97 10.1 Intel® Server Board S3420GP Design Specifications ............................................. 97 10.2 Board-level Calculated MTBF ................................................................................. 97 10.3 Server Board Power Requirements ........................................................................ 98 10.3.1 Processor Power Support ....................................................................................... 98 10.4 Power Supply Output Requirements ...................................................................... 99 10.4.1 Grounding ................................................................................................................ 99 10.4.2 Standby Outputs ...................................................................................................... 99 10.4.3 Remote Sense ......................................................................................................... 99 10.4.4 Voltage Regulation ................................................................................................ 100 10.4.5 Dynamic Loading................................................................................................... 100 10.4.6 Capacitive Loading ................................................................................................ 100 10.4.7 Closed-loop Stability ............................................................................................. 100 10.4.8 Common Mode Noise ........................................................................................... 101 10.4.9 Ripple/Noise .......................................................................................................... 101 vi
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS
Table of Contents
10.4.10 Timing Requirements ............................................................................................ 101 10.4.11 Residual Voltage Immunity in Standby Mode ....................................................... 103 10.4.12 Protection Circuits ................................................................................................. 103 11. Regulatory and Certification Information........................................................................ 105 11.1 Product Regulatory Compliance ........................................................................... 105 11.1.1 Product Safety Compliance .................................................................................. 105 11.1.2 Product EMC Compliance – Class A Compliance ................................................ 105 11.1.3 Certifications/Registrations/Declarations .............................................................. 106 11.1.4 Product Ecology Requirements ............................................................................ 106 11.2 Product Regulatory Compliance Markings ........................................................... 107 11.3 Electromagnetic Compatibility Notices ................................................................. 109 11.3.1 FCC Verification Statement (USA) ....................................................................... 109 11.3.2 ICES-003 (Canada) ............................................................................................... 110 11.3.3 Europe (CE Declaration of Conformity) ................................................................ 110 11.3.4 VCCI (Japan) ......................................................................................................... 110 11.3.5 BSMI (Taiwan) ....................................................................................................... 111 11.3.6 RRL (Korea) .......................................................................................................... 111 Appendix A: Integration and Usage Tips ............................................................................... 112
Appendix B: Integrated BMC Sensor Tables ......................................................................... 113
Appendix C: POST Code Diagnostic LED Decoder .............................................................. 119
Appendix D: POST Code Errors .............................................................................................. 123
Appendix E: Supported Intel® Server Chassis ...................................................................... 128
Glossary ..................................................................................................................................... 129
Reference Documents .............................................................................................................. 132
Revision 2.4
Intel order number E65697-010
vii
List of Figures
Intel® Server Board S3420GP TPS
List of Figures
Figure 1. Intel® Server Board S3420GPLX Picture ........................................................................ 5 Figure 2. Intel® Server Board S3420GP Layout ............................................................................. 6 Figure 3. Intel® Server Board S3420GP – Key Connector and LED Indicator IDENTIFICATION 8 Figure 4. Intel® Server Board S3420GP – Hole and Component Positions .................................. 9 Figure 5. Intel® Server Board S3420GP – Major Connector Pin Location (1 of 2) ...................... 10 Figure 6. Intel® Server Board S3420GP –Major Connector Pin Location (2 of 2) ....................... 11 Figure 7. Intel® Server Board S3420GP – Primary Side Keepout Zone ...................................... 12 Figure 8. Intel® Server Board S3420GP – Secondary Side Keepout Zone ................................. 13 Figure 9. Intel® Server Board S3420GP Rear I/O Layout ............................................................ 14 Figure 10. Intel® Server Board S3420GP Functional Block Diagram For S3420GPLX .............. 15 Figure 11. Intel® Server Board S3420GP Functional Block Diagram From S3420GPLC ........... 16 Figure 12. Intel® Server Board S3420GP Functional Block Diagram From S3420GPV ............. 17 Figure 13. Integrated BMC Hardware .......................................................................................... 29 Figure 14. Server Management Bus (SMBUS) Block Diagram ................................................... 35 Figure 15. Setup Utility — Hardware Monitor Screen Display ..................................................... 41 Figure 16. Setup Utility — Fan controller (Manual) Display ......................................................... 43 Figure 17. Setup Utility — Voltage and Temperature Status Screen .......................................... 44 Figure 18. Event Log Viewer ........................................................................................................ 46 Figure 19. Setup Utility – Main Screen Display ............................................................................ 51 Figure 20. Setup Utility – Advanced Screen Display ................................................................... 53 Figure 21. Setup Utility – Processor Configuration Screen Display ............................................ 54 Figure 22. Setup Utility – Memory Configuration Screen Display................................................ 56 Figure 23. Setup Utility – Mass Storage Controller Configuration Screen Display ..................... 58 Figure 24. Setup Utility – Serial Port Configuration Screen Display ............................................ 59 Figure 25. Setup Utility – USB Controller Configuration Screen Display .................................... 60 Figure 26. Setup Utility – PCI Configuration Screen Display ....................................................... 62 Figure 27. Setup Utility – System Acoustic and Performance Configuration Screen Display..... 63 Figure 28. Setup Utility – Security Configuration Screen Display................................................ 64 Figure 29. Setup Utility – Server Management Configuraiton Screen Display............................ 66 Figure 30. Setup Utility – Console Redirection Screen Display ................................................... 67 Figure 31. Setup Utility – Server Management System Information Screen Display .................. 69 Figure 32. Setup Utility – Boot Options Screen Display .............................................................. 70 Figure 33. Setup Utility – Delete Boot Option Screen Display ..................................................... 71 Figure 34. Setup Utility — Hard Disk Order Screen Display........................................................ 72 Figure 35. Setup Utility – CDROM Order Screen Display ........................................................... 72 Figure 36. Setup Utility — Floppy Order Screen Display............................................................. 73 Figure 37. Setup Utility – Network Device Order Screen Display................................................ 73 Figure 38. Setup Utility – Boot Manager Screen Display............................................................. 74 Figure 39. Jumper Blocks (J1A2, J1F1, J1F3, J1F2 and J1F5) .................................................. 91 viii
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS
List of Figures
Figure 40. Power Distribution Block Diagram .............................................................................. 98 Figure 41. Output Voltage Timing............................................................................................... 102 Figure 42. Turn On/Off Timing (Power Supply Signals) ............................................................ 103 Figure 43. Diagnostic LED Placement Diagram ........................................................................ 119 Revision 2.4
Intel order number E65697-010
ix
List of Tables
Intel® Server Board S3420GP TPS
List of Tables
Table 1. Intel® Server Board S3420GP Feature Set ...................................................................... 2 Table 2. Major Board Components ................................................................................................ 7 Table 3. Standard Platform DIMM Nomenclature ........................................................................ 21 Table 4. Memory Configuration Table .......................................................................................... 22 Table 5. UDIMM memory configuration rule ................................................................................ 23 Table 6. UDIMM Maximum configuration ..................................................................................... 23 Table 7. RDIMM memory configuration rule ................................................................................ 24 Table 8. RDIMM Maximum configuration ..................................................................................... 24 Table 9. Optional RMM3 Advanced Management Board Features ............................................. 30 Table 10. Serial B Header (J1B1) Pin-out .................................................................................... 30 Table 11. Video Modes ................................................................................................................. 31 Table 12. Dual Video Modes ........................................................................................................ 32 Table 13. Setup Utility — Hardware Monitor Screen Fields ........................................................ 41 Table 14. Setup Utility — Hardware Monitor Screen Fields ........................................................ 43 Table 15. Setup Utility — Voltage and Temperature Status Fields ............................................. 44 Table 16. BIOS Setup Page Layout ............................................................................................. 48 Table 17. BIOS Setup: Keyboard Command Bar ........................................................................ 49 Table 18. Setup Utility – Main Screen Fields ............................................................................... 51 Table 19. Setup Utility – Advanced Screen Display Fields .......................................................... 53 Table 20. Setup Utility – Processor Configuration Screen Fields ................................................ 54 Table 21. Setup Utility – Memory Configuration Screen Fields ................................................... 56 Table 22. Setup Utility – Mass Storage Controller Configuration Screen Fields ......................... 58 Table 23. Setup Utility – Serial Ports Configuration Screen Fields ............................................. 59 Table 24. Setup Utility – USB Controller Configuration Screen Fields ........................................ 61 Table 25. Setup Utility – PCI Configuration Screen Fields .......................................................... 62 Table 26. Setup Utility – System Acoustic and Performance Configuration Screen Fields ........ 63 Table 27. Setup Utility – Security Configuration Screen Fields ................................................... 64 Table 28. Setup Utility – Server Management Configuration Screen Fields ............................... 66 Table 29. Setup Utility – Console Redirection Configuration Fields ............................................ 68 Table 30. Setup Utility – Server Management System Information Fields .................................. 69 Table 31. Setup Utility – Boot Options Screen Fields .................................................................. 70 Table 32. Setup Utility – Delete Boot Option Fields ..................................................................... 72 Table 33. Setup Utility — Hard Disk Order Fields........................................................................ 72 Table 34. Setup Utility – CDROM Order Fields............................................................................ 73 Table 35. Setup Utility — Floppy Order Fields ............................................................................. 73 Table 36. Setup Utility – Network Device Order Fields ................................................................ 74 Table 37. Setup Utility – Boot Manager Screen Fields ................................................................ 74 Table 38. Board Connector Matrix ............................................................................................... 76 Table 39. Baseboard Power Connector Pin-out (J9A1) ............................................................... 77 x
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS
List of Tables
Table 40. SSI Processor Power Connector Pin-out (J9C1) ......................................................... 77 Table 41. Intel® RMM3 Connector Pin-out (J2C1) ....................................................................... 78 Table 42. LPC/IPMB Header Pin-out (J1H2) ............................................................................... 78 Table 43. HSBP Header Pin-out (J1J1) ....................................................................................... 78 Table 44. SGPIO Header Pin-out (J1J3) ...................................................................................... 79 Table 45. Front Panel SSI Standard 24-pin Connector Pin-out (J1C1) ....................................... 79 Table 46. System Status LED Indicator States ............................................................................ 80 Table 47. VGA Connector Pin-out (J7A1) .................................................................................... 81 Table 48. RJ-45 10/100/1000 NIC Connector Pin-out (J5A1) ..................................................... 82 Table 49. RJ-45 10/100/1000 NIC Connector Pin-out (J6A1) ..................................................... 82 Table 50. SATA Connector Pin-out (J1H4, J1H1, J1G1, J1H3, J1G3, J1F4) ............................. 83 Table 51. 50-pin PCI Express* Connector Pin-out (J2H1)........................................................... 83 Table 52. External Serial A Port Pin-out (J8A1) ........................................................................... 84 Table 53. Internal 9-pin Serial B Header Pin-out (J1B2) ............................................................. 84 Table 54. Internal USB Connector Pin-out ( J1E1, J1D1) ........................................................... 84 Table 55. Pin-out of Internal USB Connector for Floppy ( J1J2) ................................................. 85 Table 56. Pin-out of Internal USB Connector for low-profile Intel® Z-U130 Value Solid State
Drive (J3F2) ............................................................................................................................ 85 Table 57. Pin-out of adaptive riser slot/PCI Express slot 6 .......................................................... 85 Table 58. SSI 4-pin Fan Header Pin-out (J6D1, J1J4, J6J2, J7J1, J6B1) .................................. 90 Table 59. Server Board Jumpers (J1F1, J1F2, J1F3, J1F5, J1A2) ............................................. 91 Table 60. Front Panel Status LED Behavior Summary................................................................ 95 Table 61. POST Code Diagnostic LED Location ......................................................................... 96 Table 62. Server Board Design Specifications............................................................................. 97 Table 63. Intel® Xeon® Processor TDP Guidelines ...................................................................... 98 Table 64. 350-W Load Ratings ..................................................................................................... 99 Table 65. Voltage Regulation Limits ........................................................................................... 100 Table 66. Transient Load Requirements .................................................................................... 100 Table 67. Capacitve Loading Conditions ................................................................................... 100 Table 68. Ripple and Noise ........................................................................................................ 101 Table 69. Output Voltage Timing ................................................................................................ 101 Table 70. Turn On/Off Timing ..................................................................................................... 102 Table 71. Over-Current Protection (OCP) .................................................................................. 104 Table 72. Over-voltage Protection (OVP) Limits ........................................................................ 104 Table 73. Integrated BMC Core Sensors ................................................................................... 115 Table 74. POST Progress Code LED Example ......................................................................... 119 Table 75. Diagnostic LED POST Code Decoder ....................................................................... 120 Table 76. POST Error Messages and Handling ......................................................................... 123 Table 77. POST Error Beep Codes ............................................................................................ 127 Revision 2.4
Intel order number E65697-010
xi
List of Tables
Intel® Server Board S3420GP TPS
<This page is intentionally left blank.>
xii
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS
1.
Introduction
Introduction
This Technical Product Specification (TPS) provides board specific information detailing the
features, functionality, and high-level architecture of the Intel® Server Board S3420GP.
In addition, you can obtain design-level information for specific subsystems by ordering the
External Product Specifications (EPS) or External Design Specifications (EDS) for a given
subsystem. EPS and EDS documents are not publicly available and must be ordered through
your local Intel representative.
1.1
Chapter Outline
This document is divided into the following chapters:


















1.2
Chapter 1 – Introduction
Chapter 2 – Server Board Overview
Chapter 3 – Functional Architecture
Chapter 4 – Platform Management
Chapter 5 – BIOS User Interface
Chapter 6 – Connector/Header Locations and Pin-outs
Chapter 7 – Jumpers Blocks
Chapter 8 – Intel® Light-Guided Diagnostics
Chapter 9 – Design and Environmental Specifications
Chapter 10 – Regulatory and Certification Information
Chapter 11 – Regulatory and Certification Information
Appendix A – Integration and Usage Tips
Appendix B – Integrated BMC Sensor Tables
Appendix C – POST Code Diagnostic LED Decoder
Appendix D – POST Code Errors
Appendix E – Supported Intel® Server Chassis
Glossary
Reference Documents
Server Board Use Disclaimer
Intel Corporation server boards contain a number of high-density VLSI and power delivery
components that need adequate airflow to cool. Intel ensures through its own chassis
development and testing that when Intel server building blocks are used together, the fully
integrated system meets the intended thermal requirements of these components. It is the
responsibility of the system integrator who chooses not to use Intel developed server building
blocks to consult vendor datasheets and operating parameters to determine the amount of
airflow required for their specific application and environmental conditions. Intel Corporation
cannot be held responsible if components fail or the server board does not operate correctly
when used outside any of their published operating or non-operating limits.
Revision 2.4
Intel order number E65697-010
1
Overview
2.
Intel® Server Board S3420GP TPS
Overview
The Intel® Server Board S3420GP is a monolithic printed circuit board (PCB) with features
designed to support entry-level severs. It has three board SKUs: S3420GPLX, S3420GPLC,
and S3420GPV.
2.1
Intel® Server Board S3420GP Feature Set
Table 1. Intel® Server Board S3420GP Feature Set
Feature
Processor
Description
®
®
TM
Support for one Xeon Processor 3400 Series or Intel Core Processor i3-500
®
®
Series or Intel Pentium Processor G6950 in FC-LGA 1156 socket package.

2.5 GT/s point-to-point DMI interface to PCH

Memory
LGA 1156 pin socket
Two memory channels with support for 1066/1333 MHz ECC Unbuffered (UDIMM) or
®
®
ECC Registered (RDIMM) (Intel Xeon Processor 3400 Series only) DDR3.
®
Intel Server Board S3420GPLX and S3420GPLC
®
®

Up to 2 UDIMMs or 3 RDIMM (Intel Xeon Processor 3400 Series only)
per channel

32 GB max with x8 ECC RDIMM (2 Gb DRAM) and 16 GB max with x8
ECC UDIMM (2 Gb DRAM)
®
Intel Server Board S3420GPV
Chipset
®
®

Up to 2 UDIMMs or 2 RDIMM (Intel Xeon Processor 3400 Series only)
per channel

16 GB max with x8 ECC UDIMM (2 Gb DRAM) and 16 GB max with x8
ECC RDIMM (2 Gb DRAM)
Intel® Server board S3420GPLX
®

Support for Intel 3420 Chipset Platform Controller Hub (PCH)

ServerEngines* LLC Pilot II BMC controller (Integrated BMC)

PCI Express* switch
®
Intel Server board S3420GPLC
®

Support for Intel 3420 Chipset Platform Controller Hub (PCH)

ServerEngines* LLC Pilot II BMC controller (Integrated BMC)
®
Intel Server board S3420GPV

I/O
®
Support for Intel 3420 Chipset Platform Controller Hub (PCH)
External connections:

DB-15 video connectors

DB-9 serial Port A connector

Four ports on two USB/LAN combo connectors at rear of board.
Internal connections:
2

Two USB 2x5 pin headers, each supporting two USB 2.0 ports (Only one
®
header for Intel Server board S3420GPV)

One 2x5 Serial Port B header (Intel Server board S3420GPLX and
S3420GPLC)

Six SATA II connectors

One connector supports for optional Intel Remote Management Module 3
®
(Intel Server board S3420GPLX)
®
®
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS
Feature
Add-in PCI Card, PCI
Express* Card
Overview
Description
®
Intel Server Board S3420GPLX

Slot1: One 3.3V/5V PCI 32 bit/33 MHz connector.

Slot2: One PCI Express* Gen1 x4 (x1 throughput) connector.

Slot3: One PCI Express* Gen1 x8 (x4 throughput) connector.

Slot4: One PCI Express* Gen2 x8 (x4 throughput) connector.

Slot5: One PCI Express* Gen2 x8 (x8 throughput) connector.

Slot6: One PCI Express* Gen2 x16 (x8 throughput) connector.
®
Intel Server Board S3420GPLC/ S3420GPV
System Fan Support
Video

Slot1: One 3.3V/5V PCI 32 bit/33 MHz connector.

Slot3: One PCI Express* Gen1 x8 (x4 throughput) connector.

Slot5: One PCI Express* Gen2 x8 (x8 throughput) connector.

Slot6: One PCI Express* Gen2 x16 (x8 throughput) connector.
Five 4-pin fan headers supporting four system fans and one processor.
®
Intel Server Board S3420GPLX/ S3420GPLC

Onboard ServerEngines* LLC Pilot II BMC Controller

Integrated 2D Video Controller with 8MB Video Memory

64-MB DDR2 667 MHz Memory
®
Intel Server Board S3420GPV

Onboard Hard Drive

RAID Support
Silicon Motion SM712GX04LF02-BA
Support for six Serial ATA II hard drives through six onboard SATA II connectors with
SW RAID 0, 1, 5, and 10.
®
Intel Server Board S3420GPLX:
®
Up to four SAS hard drives through option Intel SAS Entry RAID Module
card
®
Intel Server Board S3420GPLX /S3420GPLC/S3420GPV

Intel® Rapid Storage RAID through onboard SATA connectors provides
SATA RAID 0, 1, 5 and 10.

Intel Embedded Server RAID Technology II through onboard SATA
connectors provides SATA RAID 0, 1, and 10.
®
®
Intel Server Board S3420GPLX
LAN
Revision 2.4
®
®

Intel Embedded Server RAID Technology II through optional Intel SAS
Entry RAID Module AXX4SASMOD provides SAS RAID 0, 1, and 10 with
®
optional RAID 5 support provided by the Intel RAID Activation Key
AXXRAKSW5

IT/IR RAID through optional Intel SAS Entry RAID Module AXX4SASMOD
provides entry level hardware RAID 0, 1, 10, and native SAS pass through
mode

Four ports full featured SAS/SATA hardware RAID through optional Intel
Integrated RAID Module SROMBSASMR (AXXROMBSASMR) provides
RAID 0, 1, 5, 6 and striping capability for spans 10, 50, 60.

One Gigabit Ethernet device 82574L connect to PCI-E x1 interfaces on the
PCH.

One Gigabit Ethernet PHY 82578DM connected to PCH through PCI-E x1
interface.
®
®
Intel order number E65697-010
3
Overview
Feature
Server Management
Intel® Server Board S3420GP TPS
Description
®
Intel Server Board S3420GPLX/S3420GPLC:
Onboard LLC Pilot II Controller (iBMC)

Integrated Baseboard Management Controller (Integrated BMC), IPMI 2.0
compliant

Integrated 2D video controller on PCI-E x1
®
Intel Server Board S3420GPLX

4
®
Intel Remote Management Module III (RMM3)
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS
2.2
Overview
Server Board Layout
Figure 1. Intel® Server Board S3420GPLX Picture
Revision 2.4
Intel order number E65697-010
5
Overview
Intel® Server Board S3420GP TPS
2.2.1
Server Board Connector and Component Layout
The following figure shows the board layout of the server board. Each connector and major
component is identified by a number or letter, and Table 2 provides the description.
A
B C D
E
F
G
H
J
I
K
L
M
N
DD
O
CC
BB
P
AA
Z
W
T
V
S
R
Q
U
X
AF003290
Y
Figure 2. Intel® Server Board S3420GP Layout
6
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS
Overview
Table 2. Major Board Components
Description
A
B
Description
Q
R
System FAN2 and System FAN 3
CPU connector
S
CPU Fan connector
T
USB SSD connector (Intel Server Board
S3420GPLX and S3420GPLC)
®
50-pin PCI Express* connector (Intel Server Board
S3420GPLX only)
F
Slot 1, 32 Mbit/33 MHz PCI
Slot 2, PCI Express* Gen1 x1 (x4 connector)
(Intel Server Board S3420GPLX only)
Intel RMM3 Connector(Intel Server Board
S3420GPLX only)
Slot 3, PCI Express* Gen1 x4 (PCI Express*
Gen2 compliant)
Slot 4, PCI Express* Gen2 x4 (x8 connector)
®
(x8 connector)( Intel Server Board S3420GPLX
only)
Slot 5. PCI Express* Gen2 x8 (x8 connector)
G
Slot 6, PCI Express* Gen2 x8 (x16 connector)
W
H
I
CMOS battery
Ethernet and Dual USB COMBO
X
Y
J
Ethernet and Dual USB COMBO
Z
K
L
System FAN 4
Video port
AA
BB
M
N
External Serial port
Main Power Connector
CC
DD
O
P
CPU Power connector
®
DIMM slots (4 slots on Intel Server Board
S3420GPV)
C
D
E
Revision 2.4
U
V
®
®
System FAN 1 (Intel Server Board S3420GPLX
and S3420GPLC)
®
IPMB(Intel Server Board S3420GPLX and
S3420GPLC)
SATA_SGPIO
®
HSBP (Intel Server Board S3420GPLX and
S3420GPLC)
®
USB Floppy (Intel Server Board S3420GPLX and
S3420GPLC)
Six SATA ports
Internal USB Connector ( One for Internal USB
®
header on Intel Server Board S3420GPV)
Front Panel Connector
®
Internal Serial Port (Intel Server Board S3420GPLX
and S3420GPLC)
Intel order number E65697-010
7
Overview
2.2.2
Intel® Server Board S3420GP TPS
Intel® Server Board S3420GP Mechanical Drawings
Figure 3. Intel® Server Board S3420GP – Key Connector and LED Indicator IDENTIFICATION
8
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS
Overview
Figure 4. Intel® Server Board S3420GP – Hole and Component Positions
Revision 2.4
Intel order number E65697-010
9
Overview
Intel® Server Board S3420GP TPS
Figure 5. Intel® Server Board S3420GP – Major Connector Pin Location (1 of 2)
10
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS
Overview
Figure 6. Intel® Server Board S3420GP –Major Connector Pin Location (2 of 2)
Revision 2.4
Intel order number E65697-010
11
Overview
Intel® Server Board S3420GP TPS
Figure 7. Intel® Server Board S3420GP – Primary Side Keepout Zone
12
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS
Overview
Figure 8. Intel® Server Board S3420GP – Secondary Side Keepout Zone
Revision 2.4
Intel order number E65697-010
13
Overview
2.2.3
Intel® Server Board S3420GP TPS
Server Board Rear I/O Layout
The following figure shows the layout of the rear I/O components for the server board.
A
Serial Port A
C
NIC Port 1 (1 Gb) and Dual USB Port
Connector
B
Video
D
NIC port 2 (1 Gb) and Dual USB Port
Connector
Figure 9. Intel® Server Board S3420GP Rear I/O Layout
14
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS
3.
Functional Architecture
Functional Architecture
The architecture and design of the Intel® Server Board S3420GP is based on the Intel® 3420
Chipset. The chipset is designed for systems based on the Intel® Xeon® Processor 3400 Series
or Intel® CoreTM i3-500 Desktop Processor Series or Intel® Pentium® Processor Processor
G6950in the FC-LGA 1156 socket package. The chipset contains two main components:
Intel® 3420 Chipset
 PCI Express* switch (Intel® Server Board S3420GPLX only).
This chapter provides a high-level description of the functionality associated with each chipset
component and the architectural blocks that make up the server board.

Figure 10. Intel® Server Board S3420GP Functional Block Diagram For S3420GPLX
Revision 2.4
Intel order number E65697-010
15
Functional Architecture
Intel® Server Board S3420GP TPS
Figure 11. Intel® Server Board S3420GP Functional Block Diagram From S3420GPLC
16
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS
Functional Architecture
Figure 12. Intel® Server Board S3420GP Functional Block Diagram From S3420GPV
3.1
Processor Sub-System
The Intel® Server Board S3420GP supports the following processor:



Intel® Xeon® Processor 3400 series
Intel® CoreTM Processor i3-500 Desktop series
Intel® Pentium® Processor G6950
The Intel® Xeon® 3400 Processor Series are made up of multi-core processors based on the 45
nm processor technology. The Intel® CoreTM Processor i3-500 Series and Intel® Pentium®
Processor G6950are made up of dual core processor based on the 32 nm processor technology.
3.1.1
Intel® Xeon® Processor 3400 Series
The Intel® Xeon® Processor 3400 Series highly integrated solution variant is composed of four
Nehalem-based processor cores.


FC-LGA 1156 socket package with 2.5 GT/s.
Up to 95 W Thermal Design Power (TDP); processors with higher TDP are not
supported.
The server board does not support previous generations of the Intel® Xeon® processors.
3.1.2
Intel® CoreTM Processor i3-500 Series and Intel® Pentium® Processor G6950
The Intel® Duo CoreTM Processor i3-500 Series and Intel® Pentium® Processor G6950 highly
integrated solution variant is composed of two processor cores.


FC-LGA 1156 socket package with 2.5 GT/s.
Up to 95 W Thermal Design Power (TDP); processors with higher TDP are not
supported.
Please get the detail supported processor list from Intel website.
3.1.3
Intel® Turbo Boost Technology
Intel® Turbo Boost Technology is featured on certain processors in the Intel® Xeon® Processor
3400 Series. Intel® Turbo Boost Technology opportunistically and automatically allows the
processor to run faster than the marked frequency if the processor is operating below power,
temperature, and current limits. This results in increased performance for both multi-threaded
and single-threaded workloads.
Intel® Turbo Boost Technology operation:


Turbo Boost operates under Operating System control – It is only entered when the
operating system requests the highest (P0) performance state.
Turbo Boost operation can be enabled or disabled by BIOS.
Revision 2.4
Intel order number E65697-010
17
Functional Architecture
Intel® Server Board S3420GP TPS
Turbo Boost converts any available power and thermal headroom into higher frequency
on active cores. At nominal marked processor frequency, many applications consume
less than the rated processor power draw.
 Turbo Boost availability is independent of the number of active cores.
 Maximum Turbo Boost frequency depends on the number of active cores and varies by
processor configuration.
 The amount of time the system spends in Turbo Boost operation depends on workload,
operating environment, and platform design.
If the processor supports the Intel® Turbo Boost Technology feature, the BIOS Setup provides
an option to enable or disable this feature. The default state is enabled.

3.1.4
Simultaneous Multithreading (SMT)
®
Most Intel Xeon® processors support Simultaneous Multithreading (SMT). The BIOS detects
processors that support this feature and enables the feature during POST.
If the processor supports this feature, the BIOS Setup provides an option to enable or disable
this feature. The default is enabled.
3.1.5
Enhanced Intel SpeedStep® Technology
Most processors support the Enhanced Intel SpeedStep® technology. This technology changes
the processor operating ratio and voltage similar to the Thermal Monitor 1 (TM1) feature. The
BIOS implements this technology in conjunction with the TM1 feature. The BIOS enables a
combination of TM1 and TM2 according to the processor BIOS writer's guide.
3.2
Memory Subsystem
The Intel® Xeon® Processor 3400 Series has an Integrated Memory Controller (IMC) in its
package. Each Intel® Xeon® Processor 3400 Series produces up to two DDR3 channels of
memory. Each DDR3 channel in the IMC supports up to three DDR3 RDIMM slots or up to two
UDIMM slots. The DDR3 RDIMM frequency can be 800/1066/1333 MHz. DDR3 UDIMM
frequency can be 1066/1333 MHz. All RDIMMs and UDIMMs include ECC (Error Correction
Code) operation. Various speeds and memory technologies are supported.
Note: Intel® Xeon® Processor L3406 only supports DDR3 Unbuffered DIMM (UDIMM).
The Intel® CoreTM Processor i3-500 Series and Intel® Pentium® Processor G6950 have an
Integrated Memory Controller (IMC) supports DDR3 protocols with two independent, 64-bit wide
channels each accessing one or two DIMMs. Only DDR3 UDIMM can be supported with the
Intel® Core® i3-500 Desktop Processor Series and Intel® Pentium® Processor G6950.
RAS (Reliability, Availability, and Serviceability) is not supported on the Intel® Server Board
S3420GP.
3.2.1
Memory Sizing and Configuration
®
The Intel Server Board S3420GP supports various memory module sizes and configurations.
These combinations of sizes and configurations are valid only for DDR3 DIMMs approved by
Intel Corporation.
18
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS
Functional Architecture
S3420GP supports:

DIMM sizes of 1 GB, 2 GB, 4 GB, and 8 GB.

DIMMs composed of DRAM using 2 Gb technology.

DRAMs organized as single rank, dual rank, or quad rank DIMMS.

DIMM speeds of 800, 1066, or 1333 MT/s.

Registered or Unregistered (unbuffered) DIMMs (RDIMMs or UDIMMs).
Note: UDIMMs should be ECC, and may or may not have thermal sensors; RDIMMs must have
ECC and must have thermal sensors.
S3420GP has the following limitations:








256 Mb technology, x4 DRAM on UDIMM, and quad rank UDIMM are NOT supported
x16 DRAM on UDIMM is not supported on combo routing
Memory suppliers not productizing native 800 ECC UDIMMs
Intel® Xeon® 3400 Series support all timings defined by JEDEC.
256 Mb/512 Mb technology, x4 and x16 DRAMs on RDIMM are NOT supported
All channels in a system will run at the fastest common frequency
No mixing of registered and unbuffered DIMMs
No mixing of different ranks or speeds on UDIMM or RDIMM.
3.2.2
Post Error Codes
The range {0xE0 - 0xEF} of POST codes is used for memory errors in early POST. In late POST,
this range is used for reporting other system errors.





0xE8 - No Usable Memory Error: If no memory is available, the system emits POST
Diagnostic LED code 0xE8 and halts the system.
0xE8 - Configuration Error: If a DDR3 DIMM has no SPD information, the BIOS treats
the DIMM slot as if no DDR3 DIMM is present on it. Therefore, if this is the only DDR3
DIMM installed in the system, the BIOS halts with POST Diagnostic LED code 0xE8 (no
usable memory) and halts the system.
0xEB - Memory Test Error: If a DDR3 DIMM or a set of DDR3 DIMMs on the same
memory channel (row) fails HW Memory BIST but usable memory remains available, the
BIOS emits a beep code and displays POST Diagnostic LED code 0xEB momentarily
during the beeping and then continues POST. If all of the memory fails HW Memory
BIST, the system acts as if no memory is available, beeping and halting with the POST
Diagnostic LED code 0xE8 (No Usable Memory) displayed.
0xEA - Channel Training Error: If the memory initialization process is unable to
properly perform the DQ/DQS training on a memory channel, the BIOS emits a beep
code and displays POST Diagnostic LED code 0xEA momentarily during the beeping. If
there is usable memory in the system on other channels, POST memory initialization
continues. Otherwise, the system halts with POST Diagnostic LED code 0xEA staying
displayed.
0xED - Population Error: If the installed memory contains a mix of RDIMMs and
UDIMMs, the system halts with POST Diagnostic LED code 0xED.
Revision 2.4
Intel order number E65697-010
19
Functional Architecture

0xEE - Mismatch Error: If more than two quad-ranked DIMMs are installed on any
channel in the system, the system halts with POST Diagnostic LED code 0xEE.
3.2.3





Intel® Server Board S3420GP TPS
Publishing System Memory
The BIOS displays the Total Memory of the system during POST if Quiet Boot is
disabled in the BIOS setup. This is the total size of memory discovered by the BIOS
during POST, and is the sum of the individual sizes of installed DDR3 DIMMs in the
system.
The BIOS displays the Effective Memory of the system in the BIOS Setup. The term
Effective Memory refers to the total size of all active DDR3 DIMMs (not disabled) and not
used as redundant units.
The BIOS provides the total memory of the system in the main page of the BIOS setup.
This total is the same as the amount described by the first bullet in this section.
If Quiet Boot is disabled, the BIOS displays the total system memory on the diagnostic
screen at the end of POST. This total is the same as the amount described by the first
bullet in this section.
The BIOS provides the total amount of memory in the system.
3.2.3.1
Memory Reservation for Memory-mapped Functions
A region of size 40 MB of memory below 4 GB is always reserved for mapping chipset,
processor, and BIOS (flash) spaces as memory-mapped I/O regions. This region appears as a
loss of memory to the operating system. In addition to this loss, the BIOS creates another
reserved region for memory-mapped PCIe functions, including a standard 64 MB or 256 MB of
standard PCI Express* MMIO configuration space.
If PAE is turned on in the operating system, the operating system reclaims all these reserved
regions.
In addition to this memory reservation, the BIOS creates another reserved region for memorymapped PCI Express* functions, including a standard 64 MB or 256 MB of standard PCI
Express* Memory Mapped I/O (MMIO) configuration space. This is based on the selection of
Maximize Memory below 4 GB in the BIOS Setup.
If this is set to Enabled, the BIOS maximizes usage of memory below 4 GB for an operating
system without PAE capability by limiting PCI Express* Extended Configuration Space to 64
buses rather than the standard 256 buses. This is done using the MAX_BUS_NUMBER feature
offered by the Intel® S3420 I/O Hub and a variably-sized Memory Mapped I/O region for the PCI
Express* functions.
3.2.3.2
High-Memory Reclaim
When 4 GB or more of physical memory is installed (physical memory is the memory installed
as DDR3 DIMMs), the reserved memory is lost. However, the Intel® 3420 chipset provides a
feature called high-memory reclaim, which allows the BIOS and operating system to remap the
lost physical memory into system memory above 4 GB (the system memory is the memory the
processor can see).
The BIOS always enables high-memory reclaim if it discovers installed physical memory equal
to or greater than 4 GB. For the operating system, the reclaimed memory is recoverable only if
the PAE feature in the processor is supported and enabled. Most operating systems support this
feature. For details, see the relevant operating system manuals.
20
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS
3.2.3.3
Functional Architecture
ECC Support
Only ECC memory is supported on this platform.
3.2.4
Memory Map and Population Rules
The following nomenclature is followed for DIMM sockets:
Note: Intel® Server Board S3420GP may support up to three DIMM sockets per channel.
Table 3. Standard Platform DIMM Nomenclature
A1
3.2.4.1
Channel A
A2
A3
B1
Channel B
B2
B3
TableMemory Subsystem Operating Frequency Determination
The rules for determining the operating frequency of the memory channels are simple, but not
necessarily straightforward. There are several limiting factors, including the number of DIMMs
on a channel and organization of the DIMM - that is, either single-rank (SR), dual-rank (DR), or
quad-rank (QR):






The speed of the processor’s IMC is the maximum speed possible.
The speed of the slowest component – the slowest DIMM or the IMC – determines the
maximum frequency, subject to further limitations.
A single 1333-MHz DIMM (SR or DR) on a channel may run at full 1333-MHz speed.
If two SR/DR DIMMs are installed on a channel, the speed is limited to 1066 MHZ.
A single QR RDIMM on a channel is limited to 1066 MHz.
Two QR RDIMMs or a mix of QR + SR/DR on a channel is limited to 800 MHz.
3.2.4.2
Memory Subsystem Nomenclature
1. DIMMs are organized into physical slots on DDR3 memory channels that belong to
processor sockets.
2. The memory channels are identified as channels A, B.
3. For Intel® Xeon® 3400 Series, each socket can support a maximum of six DIMM
sockets (three DIMM sockets per channel), which can support a maximum of six
DIMM sockets.
4. The Intel® Xeon® Processor 3400 Series on the Intel® Server Board S3420GP is
populated on the processor socket. It has an Integrated Memory Controller (IMC).
The IMC provides two DDR3 channels and groups DIMMs on the board into an
autonomous memory.
5. The DIMM identifiers on the silkscreen on the board provide information about the
channel and the processor socket to which they belong. For example, DIMM_A1 is
the first slot on channel A.
3.2.4.3
Memory Upgrade Rules
Upgrading the system memory requires careful positioning of the DDR3 DIMMs based on the
following factors:
Revision 2.4
Intel order number E65697-010
21
Functional Architecture
Intel® Server Board S3420GP TPS

Existing DDR3 DIMM population

DDR3 DIMM characteristics

Optimization techniques used by the supported processors to maximize memory
bandwidth
In the Independent Channel mode, all DDR3 channels operate independently. Slot-to-slot DIMM
matching is not required across channels (for example, A1 and B1 do not have to match each
other in terms of size, organization, and timing). DIMMs within a channel do not have to match
in terms of size and organization, but they operate in the minimal common frequency. Also,
Independent Channel mode can be used to support single DIMM configuration in channel A and
in the Single Channel mode.
You must observe the following general rules when selecting and configuring memory to obtain
the best performance from the system.
1.
2.
3.
4.
DDR3 RDIMMs must always be populated using a fill-farthest method.
DDR3 UDIMMs must always be populated on DIMM A1/A2/B1/B2.
Intel® Xeon® Processor 3400 Series support either RDIMMs or UDIMMs.
Intel® Xeon® Processor L3406, Intel® CoreTM Processor i3-500 series or Intel® Pentium®
Processor G6950 only support UDIMMs.
5. RDIMM and UDIMM CAN NOT be mixed.
6. The minimal memory set is {DIMMA1}.
7. DDR3 DIMMs on adjacent slots on the same channel do not need to be identical.
Each socket supports a maximum of six slots. Standard Intel® server boards and systems that
use the Intel® 3420 chipset support three slots per DDR3 channel, two DDR3 channels per
socket, and only one socket is supported on the Intel® Server Board S3420GP.
3.2.4.4
Memory Configuration Table
Table 4. Memory Configuration Table
Channel A
A1
RDIMM
22
A2
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Channel B
A3
B1
B2
B3
X
X
X
X
X
X
X
X
Intel order number E65697-010
X
X
Revision 2.4
Intel® Server Board S3420GP TPS
Functional Architecture
Channel A
A1
UDIMM
A2
Channel B
A3
X
B1
X
X
X
X
X
X
X
X
X
X
X
X
X
X
B2
X
B3
X
X
This table defines half of the valid memory configurations. You can exchange Channel A DIMMs
with the DIMMs on Channel B to get another half.
3.2.4.5
UDIMM Configuration rules
DIMM slots per channel
2
2
DIMMs populated per channel
1
2
Speed
1066, 1333
1066, 1333
Ranks per channel
Single Rank, Dual Rank
Single Rank, Dual Rank
Table 5. UDIMM memory configuration rule
To get the maximum memory size on UDIMM, you get the detail information from below table.
Max Memory Possible
Single Rank UDIMM
1Gb DRAM Technology
4GB
(4x 1GB DIMMs)
2Gb DRAM Technology
8GB
(4x 2GB DIMMs)
Dual Rank UDIMMs
8GB
(4x 2GB DIMMs)
16GB
(4x 4GB DIMMs)
Table 6. UDIMM Maximum configuration
Intel® Server Board S3420GP has the following limitations on UDIMM.

Not support 800MHz ECC UDIMMs

No support for LV DIMMs

256Mb technology, x4 DRAM on UDIMM and quad rank UDIMM are NOT supported
x16 DRAM is not supported on combo routing





All channels in a system will run at the fastest common frequency
No mixing of registered and unbuffered DIMMs
Non-ECC UDIMMs not supported
Mixing ECC and non-ECC UDIMMs anywhere on the platform will prevent the system to
boot/function correctly
Revision 2.4
Intel order number E65697-010
23
Functional Architecture
3.2.4.6
Intel® Server Board S3420GP TPS
RDIMM Configuration rules
DIMM slots per channel
3
DIMMs populated per channel
1
Speed
1066, 1333
Ranks per channel
Single Rank, Dual Rank
3
1
1066
Quad Rank
3
2
1066, 1333
Single Rank, Dual Rank
3
2
800*
Quad Rank
3
3**
800*
Single Rank, Dual Rank
Table 7. RDIMM memory configuration rule
To get the maximum memory size on RDIMM, refer to the following table:
Max Memory Possible
Single Rank RDIMM
1Gb DRAM Technology
6GB
(6x 1GB DIMMs)
2Gb DRAM Technology
12GB
(6x 2GB DIMMs)
Dual Rank RDIMMs
12GB
(6x 2GB DIMMs)
24GB
(6x 4GB DIMMs)
Quad Rank RDIMMs
16GB
(4x 4GB DIMMs)
32GB
(4x 8GB DIMMs)
Table 8. RDIMM Maximum configuration
Intel® Server Board S3420GP has the following limitations on RDIMM:
Note: Intel® Server Board S3420GPV has two DIMM slots per channel on board and totally four
DIMM slots which support maximum RDIMM size to 16GB (4x 4GB DIMMs) because of thermal
limitation without BMC control.

No support for LV DIMMs

256Mb/512Mb technology, x4 and x16 DRAMs on RDIMM are NOT supported
All channels in a system will run at the fastest common frequency
No mixing of registered and unbuffered DIMMs


Note : 1066MHz or 1333MHz RDIMMs run at 800MHz.
3.3
Intel® 3420 Chipset PCH
The Intel® 3420 Chipset component is the Platform Controller Hub (PCH). The PCH is designed
for use with Intel® processor in a UP server platform. The role of the PCH in Intel® Server Board
S3420GP is to manage the flow of information between its eleven interfaces:

24
DMI interface to Processor
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS

PCI Express* Interface

PCI Interface

SATA Interface

USB Host Interface

SMBus Host Interface

SPI Interface

LPC interface to IBMC

JTAG interface

LAN interface

ACPI interface
3.4
Functional Architecture
I/O Sub-system
Intel® 3420 Chipset PCH provides extensive I/O support.
3.4.1
PCI Express Interface
Two different PCI-E configurations on single board are dependent on different board SKUs:



Intel® Server Board S3420GPLX
One PCI-E X16 slot connected to the PCI-E ports of CPU. Two PCI-E x8 slots and one SAS
module connected to PCI-E ports of PCIe switch. One PCI-E X8 slot and one PCI-E x4 slot
connected to the PCI-E ports of PCH.
Intel® Server Board S3420GPLC
One PCI-E X16 slot and one PCI-E X8 slot connected to the PCI-E ports of CPU. One PCIE x8 slot connected to the PCI-E ports of PCH.
Intel® Server Board S3420GPV
One PCI-E X16 slot and one PCI-E X8 slot connected to the PCI-E ports of CPU. One PCIE x8 slot connected to the PCI-E ports of PCH.
There is one 32-bit, 33-MHz, 3.3-V/5-V PCI slot.
Compatibility with the PCI addressing model is maintained to ensure all existing applications
and drivers operate unchanged.
The PCI Express* configuration uses standard mechanisms as defined in the PCI Plug-andPlay specification. The initial recovered clock speed of 1.25 GHz results in 2.5 Gb/s/direction,
which provides a 250-MB/s communications channel in each direction (500 MB/s total). This is
close to twice the data rate of classic PCI. The fact that 8b/10b encoding is used accounts for
the 250 MB/s where quick calculations would imply 300 MB/s. The external graphics ports
support 5.0 GT/s speed as well. Operating at 5.0 GT/s results in twice as much bandwidth per
lane as compared to 2.5 GT/s operation.
When operating with two PCI Express* controllers, each controller can operate at either 2.5
GT/s or 5.0 GT/s. The PCI Express* architecture is specified in three layers: Transaction Layer,
Data Link Layer, and Physical Layer. The partitioning in the component is not necessarily along
these same boundaries.
Revision 2.4
Intel order number E65697-010
25
Functional Architecture
3.4.2
Intel® Server Board S3420GP TPS
Serial ATA Support
®
The Intel 3420 Chipset has two integrated SATA host controllers that support independent
DMA operation on up to six ports and supports data transfer rates of up to 3.0 GB/s (300 MB/s).
The SATA controller contains two modes of operation – a legacy mode using I/O space and an
AHCI mode using memory space.
Software that uses legacy mode does not have AHCI capabilities. The Intel® 3420 Chipset
supports the Serial ATA Specification, Revision 1.0a. The Ibex Peak also supports several
optional sections of the Serial ATA II: Extensions to Serial ATA 1.0 Specification, Revision 1.0
(AHCI support is required for some elements).
3.4.2.1 Intel® Matrix Storage Technology
The Intel® 3420 Chipset provides support for Intel® Matrix Storage Technology, providing both
AHCI (see above for details on AHCI) and integrated RAID functionality. The industry leading
RAID capability provides high-performance RAID 0, 1, 5, and 10 functionality on up to six SATA
ports of PCH. Matrix RAID support is provided to allow multiple RAID levels to be combined on
a single set of hard drives, such as RAID 0 and RAID 1 on two disks. Other RAID features
include hot spare support, SMART alerting, and RAID 0 autos replace. Software components
include an Option ROM for pre-boot configuration and boot functionality, a Microsoft Windows*
compatible driver, and a user interface to configure and manage the RAID capability of the
Intel® 3420 Chipset.
3.4.3
USB 2.0 Support
®
On the Intel 3420 Chipset, the USB controller functionality is provided by the dual EHCI
controllers with an interface for up to ten USB 2.0 ports. All ports are high-speed, full-speed, and
low-speed capable.

Four external connectors are located on the back edge of the server board.

Two internal 2x5 header (J1E2 and J1D1) are provided, each supporting two optional
USB 2.0 ports.

One port on internal vertical connector to support NIC.

One port on 1x4pin (J1J2) on-board header on Intel® Server Board S3420GPLX and
S3420GPLC) to support floppy.
3.4.3.1 Native USB Support
During the power-on self test (POST), the BIOS initializes and configures the USB subsystem.
The BIOS is capable of initializing and using the following types of USB devices.

USB Specification-compliant keyboards

USB Specification-compliant mouse

USB Specification-compliant storage devices that utilize bulk-only transport mechanism
USB devices are scanned to determine if they are required for booting.
The BIOS supports USB 2.0 mode of operation, and as such supports USB 1.1 and USB 2.0
compliant devices and host controllers.
26
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS
Functional Architecture
During the pre-boot phase, the BIOS automatically supports the hot addition and hot removal of
USB devices and a short beep is emitted to indicate such an action. For example, if a USB
device is hot plugged, the BIOS detects the device insertion, initializes the device, and makes it
available to the user. During POST, when the USB controller is initialized, it emits a short beep
for each USB device plugged into the system as they were all just “hot added”.
Boards and systems based on the Intel® Server Board S3420GPLX or S3420GPLC are
designed to indicate USB readiness by a series of beep codes during POST, before video
becomes available. These beeps indicate that the USB is powered and initialized. Devices such
as a pen drive or USB CD/DVD ROM drive attached to external USB port will generate a beep
code once the device is recognized, powered and initialized. These beep codes do not signal
any error. They signal USB and external device readiness during POST.
Only on-board USB controllers are initialized by BIOS. This does not prevent the operating
system from supporting any available USB controllers including add-in cards.
3.4.3.2 Legacy USB Support
The BIOS supports PS/2 emulation of USB keyboards and mouse. During POST, the BIOS
initializes and configures the root hub ports and searches for a keyboard and/or a mouse on the
USB hub and then enables the devices that are recognized.
3.5
Optional Intel® SAS Entry RAID Module AXX4SASMOD
The Intel® Server Board S3420GPLX provides one 50-pin PCI Express* connector (J2H1) for
the installation of an optional Intel® SAS Entry RAID Module AXX4SASMOD. Once the optional
Intel® SAS Entry RAID Module AXX4SASMOD is detected, the x4 PCI Express* links from the
PCI switches to the 50-pin PCI Express* connector. The optional Intel® SAS Entry RAID Module
AXX4SASMOD includes a SAS1064e controller that supports x4 PCI Express* link widths and
is a single-function PCI Express* end-point device.
The SAS controller supports the SAS protocol as described in the Serial Attached SCSI
Standard, version 1.0, and also supports SAS 1.1 features. A 32-bit external memory bus off the
SAS1064e controller provides an interface for Flash ROM and NVSRAM (Non-volatile Static
Random Access Memory) devices.
The optional Intel® SAS Entry RAID Module AXX4SASMOD provides four SAS connectors that
support up to four hard drives with a non-expander backplane or up to eight hard drives with an
expander backplane.
4 ports full featured SAS/SATA hardware RAID through optional Intel® Integrated RAID Module
SROMBSASMR (AXXROMBSASMR), provides RAID 0, 1, 5, 6 and striping capability for spans
10, 50, 60.
3.6
Integrated Baseboard Management Controller
The Intel® Server Board S3420GPLX and Intel® Server Board S3420GPLC have the integrated
baseboard management controller, but Intel® Server Board S3420GPV does not have the
integrated baseboard management control.
Revision 2.4
Intel order number E65697-010
27
Functional Architecture
Intel® Server Board S3420GP TPS
The ServerEngines* LLC Pilot II Integrated BMC is provided by an embedded ARM9 controller
and associated peripheral functionality that is required for IPMI-based server management.
Firmware usage of these hardware features is platform-dependant.
The following is a summary of the Integrated BMC management hardware features used by the
ServerEngines* LLC Pilot II Integrated BMC:












250 MHz 32-bit ARM9 Processor
Memory Management Unit (MMU)
Two 10/100 Ethernet Controllers with NC-SI support
16-bit DDR2 667 MHz interface
Dedicated RTC
12 10-bit ADCs
Eight Fan Tachometers
Four PWMs
Battery-backed Chassis Intrusion I/O Register
JTAG Master
Six I2C interfaces
General-purpose I/O Ports (16 direct, 64 serial)
Additionally, the ServerEngines* Pilot II part integrates a super I/O module with the following
features:

KCS/BT Interface

Two 16C550 Serial Ports

Serial IRQ Support

12 GPIO Ports (shared with BMC)

LPC to SPI Bridge

SMI and PME Support
The Pilot II contains an integrated KVMS subsystem and graphics controller with the following
features:
28

USB 2.0 for keyboard, mouse, and storage devices

USB 1.1 interface for legacy PS/2 to USB bridging

Hardware Video Compression for text and graphics

Hardware encryption

2D Graphics Acceleration

DDR2 graphics memory interface

Up to 1600x1200 pixel resolution

PCI Express* x1 support
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS
Functional Architecture
Figure 13. Integrated BMC Hardware
3.6.1
Integrated BMC Embedded LAN Channel
The Integrated BMC hardware includes two dedicated 10/100 network interfaces.
Interface 1: This interface is available from either of the available NIC ports in system that can
be shared with the host. Only one NIC may be enabled for management traffic at any time. To
change the NIC enabled for management traffic, please use the “Write LAN Channel Port” OEM
IPMI command. The default active interface is port 1 (NIC1).
Interface 2: This interface is available from the optional RMM3 which is a dedicated
management NIC that is not shared with the host.
For these channels, support can be enabled for IPMI-over-LAN and DHCP.
For security reasons, embedded LAN channels have the following default settings:
 IP Address: Static
 All users disabled
3.6.2
Optional RMM3 Advanced Management Board
®
Intel Server Board S3420GPLX provides one RMM3 module slot. RMM3 advanced
management board serves two purposes:
Revision 2.4
Intel order number E65697-010
29
Functional Architecture
Intel® Server Board S3420GP TPS

Give the customer the option to add a dedicated management 100 Mbit LAN interface to
the product.

Provide additional flash space, enabling the Advanced Management functions to support
WS-MAN and CIMON.
Table 9. Optional RMM3 Advanced Management Board Features
Feature
KVM Redirection
Description
Remote console access via keyboard, video, and mouse redirection over LAN.
USB Media Redirection
Remote USB media access over LAN.
WS-MAN
Full SMASH profiles for WS-MAN based consoles.
3.6.3
Serial Ports
The server board provides two serial ports: an external DB9 serial port connector and an
internal DH-10 serial header.
The rear DB9 serial A port is a fully-functional serial port that can support any standard serial
device.
The Serial B port is an optional port accessed through a 9-pin internal DH-10 header (J1B1).
You can use a standard DH-10 to DB9 cable to direct serial A port to the rear of a chassis. The
serial B interface follows the standard RS-232 pin-out as defined in the following table.
Table 10. Serial B Header (J1B1) Pin-out
3.6.4
Pin
1
Signal Name
DCD
2
DSR
3
RX
4
RTS
5
TX
6
CTS
7
DTR
8
RI
9
GND
Serial Port B Header Pin-out
Floppy Disk Controller
The server board does not support a floppy disk controller interface. However, the system BIOS
recognizes USB floppy devices.
3.6.5
Keyboard and Mouse Support
The server board does not support PS/2 interface keyboards and mouse. However, the system
BIOS recognizes USB specification-compliant keyboard and mouse.
30
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS
3.6.6
Functional Architecture
Wake-up Control
The super I/O contains functionality that allows various events to power on and power off the
system.
3.7
Video Support
3.7.1
Intel® Server Board S3420GPLX and Intel® Server Board S3420GPLC
The server board includes on-board Server Engine* LLC Pilot II* Controller with 64 MB DDR2
memory in which 8MB is usable/accessible memory for iBMC video/graphic display functions.
The graphic controller internally has access to larger memory for the internal operations. The
32MB memory reported by display driver is the attached memory. Attached memory can be
32MB or greater but only 8MB is accessible for display functions. The SVGA subsystem
supports a variety of modes, up to 1600 x 1200 resolution under 2D. It also supports both CRT
and LCD monitors up to a 100 Hz vertical refresh rate..
The video is accessed using a standard 15-pin VGA connector found on the back edge of the
server board. The on-board video controller can be disabled using the BIOS Setup utility or
when an add-in video card is detected. The system BIOS provides the option for dual-video
operation when an add-in video card is configured in the system.
3.7.1.1
Video Modes
The integrated video controller supports all standard VGA modes. The following table shows the
2D modes supported for both CRT and LCD.
Table 11. Video Modes
2D Mode
Resolution
640x480
800x600
1024x768
1152x864
1280x1024
Revision 2.4
8 bpp
Supported
60, 72, 75, 85
2D Video Mode Support (Color Bit)
16 bpp
24 bpp
Supported
Supported
60, 72, 75, 85
60, 72, 75, 85
32 bpp
Supported
60, 72, 75, 85
Supported
56, 60, 72, 75,
85
Supported
56, 60, 72, 75,
85
Supported
56, 60, 72, 75,
85
Supported
56, 60, 72, 75,
85
Supported
60, 70, 75, 85
Supported
60, 70, 75, 85
Supported
60, 70, 75, 85
Supported
60, 70, 75, 85
Supported
75
Supported
75
Supported
75
N/A
N/A
Supported
60, 75, 85
Supported
60, 75, 85
Supported
60
N/A
N/A
Intel order number E65697-010
Monitor
Refresh Rate
(Hz)
Monitor
Refresh Rate
(Hz)
Monitor
Refresh Rate
(Hz)
Monitor
Refresh Rate
(Hz)
Monitor
Refresh Rate
31
Functional Architecture
2D Mode
Resolution
Intel® Server Board S3420GP TPS
8 bpp
2D Video Mode Support (Color Bit)
16 bpp
24 bpp
32 bpp
(Hz)
1440x900
1600x1200
3.7.1.2
Supported
60
Supported
60
Supported
60
N/A
N/A
Supported
60, 65, 70, 75,
85
Supported
60, 65, 70
N/A
N/A
N/A
N/A
Monitor
Refresh Rate
(Hz)
Monitor
Refresh Rate
(Hz)
Dual Video
The BIOS supports both single-video and dual-video modes. The dual-video mode is disabled
by default.




In the single mode (dual monitor video = disabled), the on-board video controller is
disabled when an add-in video card is detected.
In single mode, the onboard video controller is disabled when an add-in video card is
detected.
In dual mode, the onboard video controller is enabled and is the primary video device.
The external video card is allocated resources and is considered the secondary video
device.
When KVM is enabled in iBMC FW, dual video is enabled.
Table 12. Dual Video Modes
Onboard Video
Dual Monitor Video
3.7.2
Enabled
Disabled
Onboard video controller.
Warning: System video is completely disabled if
this option is disabled and an add-in video
adapter is not installed.
Enabled
Disabled
If enabled, both the onboard video controller and
an add-in video adapter are enabled for system
video. The onboard video controller becomes
the primary video device.
Video for Intel® Server Board S3420GPV
SM712 is a one video chip from Silicon Motion, Inc (SMI). It is one in SMI’s LynxEM family. It is
PCI 2.1 compliant with the standard PCI 33MHz & 66 MHz PCI Master/Slave interface.





32
33 MHz & 66 MHz PCI Master/Slave interface
PCI 2.1 compliant
Memory control is provided for the 4MB internal memory
Support 640x480, 800x600, 1024x768 resolution and up to 85Hz.
Dual Video mode is supported.
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS
3.8
Functional Architecture
Network Interface Controller (NIC)
The Intel® Server Board S3420GPLX, S3420GPLC and S3420GPV support two network
interfaces, One is provided from the onboard Intel® 82574L GbE PCI Express network controller;
the other is the onboard Intel® 82578 Gigabit Network controller.
3.8.1
GigE Controller 82574L
The 82574 family (82574L and 82574IT) are single, compact, low-power components that offer
a fully-integrated Gigabit Ethernet Media Access Control (MAC) and Physical Layer (PHY) port.
The 82574 uses the PCI Express* architecture and provides a single-port implementation in a
relatively small area so it can be used for server and client configurations as a LAN on
Motherboard (LOM) design.
External interfaces provided on the 82574:
 PCIe Rev. 2.0 (2.5 GHz) x1
 MDI (Copper) standard IEEE 802.3 Ethernet interface for 1000BASE-T, 100BASETX,
and 10BASE-T applications (802.3, 802.3u, and 802.3ab)
 NC-SI or SMBus connection to a Manageability Controller (MC)
 EEE 1149.1 JTAG (note that BSDL testing is NOT supported)
3.8.2
GigE PHY 82578DM
The 82578 is a single port Gigabit Ethernet Physical Layer Transceiver (PHY). It connects to the
Media Access Controller (MAC) through a dedicated interconnect. The 82578DM supports
operation at 1000/100/10 Mb/s data rates. The PHY circuitry provides a standard IEEE 802.3
Ethernet interface for 1000BASE-T, 100BASE-TX, and 10BASE-T applications (802.3, 802.3u,
and 802.3ab).
The 82578 operates with the Platform Controller Hub (PCH) chipset that incorporates the MAC.
The 82578 interfaces with its MAC through two interfaces: PCIe-based and SMBus. The PCIe
(main) interface is used for all link speeds when the system is in an active state (S0) while the
SMBus is used only when the system is in a low power state (Sx). In SMBus mode, the link
speed is reduced to 10 Mb/s. The PCIe interface incorporates two aspects: a PCIe SerDes
(electrically) and a custom logic protocol.
3.8.3
MAC Address Definition
®
Each Intel Server Board S3420GPLX has the following four MAC addresses assigned to it at
the Intel factory:
NIC 1 MAC address
NIC 2 MAC address – Assigned the NIC 1 MAC address +1
 Integrated BMC LAN Channel MAC address – Assigned the NIC 1 MAC address +2
 Intel® Remote Management Module 3 (Intel® RMM3) MAC address – Assigned the NIC 1
MAC address +3
Each Intel® Server Board S3420GPLC has the following three MAC addresses assigned to it at
the Intel factory:




NIC 1 MAC address
NIC 2 MAC address – Assigned the NIC 1 MAC address +1
Revision 2.4
Intel order number E65697-010
33
Functional Architecture
Intel® Server Board S3420GP TPS
Integrated BMC LAN Channel MAC address – Assigned the NIC 1 MAC address +2
Each Intel® Server Board S3420GPV has the following two MAC addresses assigned to it at the
Intel® factory:



3.9
NIC 1 MAC address
NIC 2 MAC address – Assigned the NIC 1 MAC address +1
Intel® I/O Acceleration Technology 2 (Intel® I/OAT2)
The Intel® 3420 chipset series platforms do not support Intel® I/O Acceleration Technology.
3.9.1
Direct Cache Access (DCA)
Direct Cache Access (DCA) is not supported on Intel® Xeon® Processor 3400 Series.
3.10 Intel® Virtualization Technology for Directed I/O (Intel® VT-d)
The Intel® 3420 chipset provides hardware support for implementation of Intel® Virtualization
Technology with Directed I/O (Intel® VT-d). Intel VT-d Technology consists of technology
components that support the virtualization of platforms based on Intel® Architecture Processor.
Intel VT-d Technology enables multiple operating systems and applications to run in dependent
partitions. A partition behaves like a virtual machine (VM) and provides isolation and protection
across partitions. Each partition is allocated its own subset of host physical memory.
The Intel® Virtualization Technology is designed to support multiple software environments
sharing the same hardware resources. The Intel® Virtualization Technology can be enabled or
disabled in the BIOS setup. The default behavior is disabled.
Note: If the setup options are changed to enable or disable the Virtualization Technology setting
in the processor, the user must perform an AC power cycle for the changes
to take effect.
34
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS
4.
Platform Management
Platform Management
This chapter is only for The Intel® Server Board S3420GPLX and Intel® Server Board
S3420GPLC.
The platform management subsystem is based on the Integrated BMC features of the
ServerEngines* Pilot II. The onboard platform management subsystem consists of
communication buses, sensors, system BIOS, and server management firmware. The following
diagram provides an overview of the Server Management Bus (SMBUS) architecture used on
this server board.
Figure 14. Server Management Bus (SMBUS) Block Diagram
4.1 Feature Support
4.1.1
IPMI 2.0 Features

Integrated Baseboard Management Controller (Integrated BMC).

IPMI Watchdog timer.

Messaging support, including command bridging and user/session support.

Chassis device functionality, including power/reset control and BIOS boot flags support.

Event receiver device: The Integrated BMC receives and processes events from other
platform subsystems.
Revision 2.4
Intel order number E65697-010
35
Platform Management
Intel® Server Board S3420GP TPS

Field replaceable unit (FRU) inventory device functionality: The Integrated BMC supports
access to system FRU devices using IPMI FRU commands.

System event log (SEL) device functionality: The Integrated BMC supports and provides
access to a SEL.

Sensor device record (SDR) repository device functionality: The Integrated BMC
supports storage and access of system SDRs.

Sensor device and sensor scanning/monitoring: The Integrated BMC provides IPMI
management of sensors. It polls sensors to monitor and report system health.

IPMI interfaces.
o Host interfaces include system management software (SMS) with receive
message queue support and server management mode (SMM).
o
Terminal mode serial interface
o
IPMB interface
o
LAN interface that supports the IPMI-over-LAN protocol (RMCP, RMCP+)

Serial-over-LAN (SOL)

ACPI state synchronization: The Integrated BMC tracks ACPI state changes provided by
the BIOS.

Integrated Baseboard Management Controller (Integrated BMC) self test: The Integrated
BMC performs initialization and run-time self tests, and makes results available to
external entities.
For more information, refer to the IPMI 2.0 Specification.
4.1.2
Non-IPMI Features
The Integrated BMC supports the following non-IPMI features. This list does not preclude
support for future enhancements or additions.
36

In-circuit Integrated BMC firmware update.

Fault resilient booting (FRB): FRB2 is supported by the watchdog timer functionality

Chassis intrusion detection and chassis intrusion cable presence detection.

Basic fan control using TControl version 2 SDRs.

Acoustic management: Support for multiple fan profiles.

Signal testing support: The Integrated Baseboard Management Controller (Integrated
BMC) provides test commands for setting and getting platform signal states.

The Integrated Baseboard Management Controller (Integrated BMC) generates
diagnostic beep codes for fault conditions.

System GUID storage and retrieval.

Front panel management: The Integrated Baseboard Management Controller (Integrated
BMC) controls the system status LED and chassis ID LED. It supports secure lockout of
certain front panel functionality and monitors button presses. The chassis ID LED is
turned on using a front panel button or a command.

Power state retention

Power fault analysis

Intel® Light-Guided Diagnostics
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS
Platform Management

Power unit management: Support for power unit sensor. The Integrated Baseboard
Management Controller (Integrated BMC) handles power-good dropout conditions.

DIMM temperature monitoring: New sensors and improved acoustic management using
closed-loop fan control algorithm taking into account DIMM temperature readings.

Address Resolution Protocol (ARP): The Integrated BMC sends and responds to ARPs
(supported on embedded NICs)

Dynamic Host Configuration Protocol (DHCP): The Integrated BMC performs DHCP
(supported on embedded NICs).

Platform environment control interface (PECI) thermal management support.

E-mail alerting

Embedded web server

Integrated KVM

Integrated Remote Media Redirection

Lightweight Directory Authentication Protocol (LDAP) support
4.2
Optional Advanced Management Feature Support
This section explains the advanced management features supported by the Integrated
Baseboard Management Controller (Integrated BMC) firmware.
4.2.1
Enabling Advanced Management Features
The Integrated BMC enables the advanced management features only when it detects the
presence of the Intel® Remote Management Module 3 (Intel® RMM3) card. Without the Intel®
RMM3, the advanced features are dormant. Only the Intel® Server Board S3420GPLX has a
RMM3 module interface.
4.2.1.1
Intel® RMM3
The Intel® RMM3 provides the Integrated BMC with an additional dedicated network interface.
The dedicated interface consumes its own LAN channel. Additionally, the Intel® RMM3 provides
additional flash storage for advanced features like Web Services for Management (WS-MAN).
4.2.2
Keyboard, Video, Mouse (KVM) Redirection
The Integrated BMC firmware supports keyboard, video, and mouse redirection over LAN. This
feature is available remotely from the embedded web server as a Java applet. This feature is
enabled only when the Intel® RMM3 is present. The client system must have a Java Runtime
Environment (JRE) version 5.0 or later to run the KVM or media redirection applets.
4.2.2.1
Keyboard and Mouse
The keyboard and mouse are emulated by the Integrated BMC as USB human interface devices.
4.2.2.2
Video
Video output from the KVM subsystem is equivalent to the video output on the local console.
Video redirection is available after video is initialized by the system BIOS. The KVM video
resolution and refresh rates will always match the values set in the operating system.
Revision 2.4
Intel order number E65697-010
37
Platform Management
4.2.2.3
Intel® Server Board S3420GP TPS
Availability
Up to two remote KVM sessions are supported. The default inactivity timeout is 30 minutes;
however, this can be changed through the embedded web server. Remote KVM activation does
not disable the local system keyboard, video, or mouse. Unless the feature is disabled locally,
remote KVM is not deactivated by local system input.
KVM sessions persist across system reset but not across an AC power loss.
4.2.3
Media Redirection
The embedded web server provides a Java applet to enable remote media redirection. This may
be used in conjunction with the remote KVM feature or as a standalone applet.
The media redirection feature is intended to allow system administrators or users to mount a
remote IDE or USB CD-ROM, floppy drive, or a USB flash disk as a remote device to the server.
Once mounted, the remote device appears just like a local device to the server, allowing system
administrators or users to install software (including operating systems), copy files, update the
BIOS, and so forth, or boot the server from this device.
The following capabilities are supported:
 The operation of remotely mounted devices is independent of the local devices on the
server. Both remote and local devices are usable in parallel

Either IDE (CD-ROM, floppy) or USB devices can be mounted as a remote device to the
server.

It is possible to boot all supported operating systems from the remotely mounted device
and to boot from disk IMAGE (*.IMG) and CD-ROM or DVD-ROM ISO files. Refer to the
Tested/supported Operating System List for more information.

It is possible to mount at least two devices concurrently.

The mounted device is visible to (and useable by) the managed system’s operating
system and BIOS in both pre-boot and post-boot states.

The mounted device shows up in the BIOS boot order and it is possible to change the
BIOS boot order to boot from this remote device.

It is possible to install an operating system on a bare metal server (no operating system
present) using the remotely mounted device. This may also require the use of KVM-r to
configure the operating system during install.
If either a virtual IDE or virtual floppy device is remotely attached during system boot, both
virtual IDE and virtual floppy are presented as bootable devices. It is not possible to present
only a single mounted device type to the system BIOS.
4.2.3.1
Availability
The default inactivity timeout is 30 minutes, but may be changed through the embedded web
server.
Media redirection sessions persist across system reset but not across an AC power loss.
4.2.4
Web Services for Management (WS-MAN)
The Integrated BMC firmware supports the Web Services for Management (WS-MAN)
specification, version 1.0.
38
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS
4.2.5
Platform Management
Local Directory Authentication Protocol (LDAP)
The Integrated BMC firmware supports the Local Directory Authentication Protocol (LDAP)
protocol for user authentication.
Note: IPMI users/passwords and sessions are not supported over LDAP.
4.2.6
Embedded Webserver
The Integrated BMC provides an embedded web server for out-of-band management. User
authentication is handled by IPMI user names and passwords. Base functionality for the
embedded web server includes:

Power Control – Limited control based on IPMI user privilege.

Sensor Reading – Limited access based on IPMI user privilege.

SEL Reading – Limited access based on IPMI user privilege.

KVM/Media Redirection – Limited access based on IPMI user privilege. Only available
when the Intel® RMM3 is present.

IPMI User Management – Limited access based on IPMI user privilege.
The web server is available on all enabled LAN channels.
See Appendix B for Integrated BMC core sensors.
4.3
Management Engine (ME)
Intel Management Engine is tied to essential platform functionality. This Management Engine
firmware includes the following applications:

Platform Clocks – Tune PCH clock silicon to the parameters of a specific board,
configure clocks at run time, power management clocks.

Thermal Report – ME FW reports thermal and power information available only on PECI
to host accessible registers/Embedded Controller via SMBus.
Revision 2.4
Intel order number E65697-010
39
Server Management Capability for Intel® Server Board S3420GPV
5.
5.1
Intel® Server Board S3420GP TPS
Server Management Capability for Intel® Server Board
S3420GPV
Super I/O
5.1.1
Key Features of Super I/O
The W83627DHG-P is from the Nuvoton's Super I/O product line. This family features the LPC
(Low Pin Count) interface. This interface is more economical than its ISA counterpart. It has
approximately forty pins less, yet it provides as great performance. In addition, the improvement
allows even more efficient operation of software, BIOS, and device drivers.
The W83627DHG-P provides below key features

Meet LPC Spec. 1.01

Integrated hardware monitor functions

Support ACPI (Advanced Configuration and Power Interface)

Support up to 2 16550-compatible UARTs ports

8042-based keyboard controller

Smart Fan control system

Five fan-speed monitoring inputs

Four fan-speed controls

GPIO

Support PECI 1.0 and 1.1a Specifications
5.1.2
Sensor and Hardware Monitor
Hardware Monitor Screen allows the user to configure Fan speed control and show the
monitored voltage to user. To access this screen from the BIOS Main screen, choose Server
Management > Hardware Monitor.
Fan Speed Control management has two options.
40

Auto – is for SC5299UP chassis support.

300m, 900m, 1500m, 3000m can be selected according to the local altitude where the
system is placed to assure the system is properly cooled. The default altitude setting
is 900m.
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS

Advance
d
Hardware monitor
Main
Security
Server Management Capability for Intel® Server Board S3420GPV
Server Management
Boot
Options
Boot
Manager

Real-time Temperature and Voltage Status
Fan Controller
Auto/Manual
CPU Fan Altitude
Board Fan Altitude
300m/900m/1500m/3000m
300m/900m/1500m/3000m
Figure 15. Setup Utility — Hardware Monitor Screen Display
Table 13. Setup Utility — Hardware Monitor Screen Fields
Setup Item
Voltage and
Temperature Status
Revision 2.4
Options
Help Text
display monitored voltage, current
Fan speed PWM and temperature
CPU Fan Controller
Auto
Manual
CPU temperature control policy
Auto - Fan speed control setting by
default
Manual - user adjust Fan speed
control setting value manually
CPU Fan Altitude
300m/900m/1500m/3000m
Select CPU FAN default PWM
according to altitude under Auto
mode
Board Fan Altitude
300m/900m/1500m/3000m
Select Board Fan default PWM
according to altitude under Auto
mode
Hysteresis
2 Degree Celsius
3 Degree Celsius
4 Degree Celsius
Hysteresis – is used to smoothing
the FAN speed transition when
temperature approaching
temperature target upward or
downward. Select Hysteresis to keep
FAN at the same speed within the
range
Default Fan PWM
40%
60%
80%
100%
Select Default FAN PWM to make
FAN speed keep the invariable
speed when temperature is below
FSC temperature target at low user
conditions. This delivers optimized
acoustic level
Intel order number E65697-010
41
Server Management Capability for Intel® Server Board S3420GPV
Intel® Server Board S3420GP TPS
Note: The two options of Hysteresis and Default Fan PWM apply to all the four fans
5.1.3
Fan controller (Manual)
Fan controller (Manual) allows the user to configure Fan speed control manually. To access this
screen from the Main screen, choose Server Management > Hardware Monitor > Fan
controller (Manual).
[Manual] is designed for the third party chassis which supports four fan headers. Each of them
has four minimum fan PWM output selections 40%, 60%, 80%, and 100% and associated with
different cooling capabilities as well as different acoustic levels. The default PWM is 100% and
can be customized to 40%, 60%, 80% according to the third party chassis cooling capability and
acoustic requirement.
Hysteresis is used to prevent fan oscillation when temperature is crossing the target control
temperature back and forth.
42
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS

Main
Server Management Capability for Intel® Server Board S3420GPV
Advanc
Secu rit
Server
Boot
ed
y
Management
Options
Boot Manager

Hardware monitor
Real-time Temperature and Voltage Status
Fan Controller
Manual
CPU Fan
Hysteresis
[2 Degree Celsius/3 Degree Celsius/4 Degree Celsius
Default Fan PW M
[40%/60%/80%/100%]
System Fan
Hysteresis
[2 Degree Celsius/3 Degree Celsius/4 Degree Celsius
Default Fan PWM
[40%/60%/80%/100%]
Auxiliary Fan 1
Hysteresis
[2 Degree Celsius/3 Degree Celsius/4 Degree Celsius
Default Fan PWM
[40%/60%/80%/100%]
Auxiliary Fan 2
Hysteresis
[2 Degree Celsius/3 Degree Celsius/4 Degree Celsius
Default Fan PWM
[40%/60%/80%/100%]
Figure 16. Setup Utility — Fan controller (Manual) Display
Table 14. Setup Utility — Hardware Monitor Screen Fields
Setup Item
Voltage and
Temperature Status
CPU Fan Controller
Revision 2.4
Options
Auto
Manual
Help Text
display monitored voltage, current
Fan speed PWM and temperature
CPU temperature control policy
Auto - Fan speed control setting by
default
Manual - user adjust Fan speed
control setting value manually
Intel order number E65697-010
Comments
43
Server Management Capability for Intel® Server Board S3420GPV
Setup Item
Intel® Server Board S3420GP TPS
Options
300m/900m/1500m/3000m
Help Text
CPU Fan Altitude
System Fan Altitude
300m/900m/1500m/3000m
Hysteresis
2 Degree Celsius
3 Degree Celsius
4 Degree Celsius
Select Board Fan default PWM
according to altitude under Auto
mode
Hysteresis – is used to smoothing
the FAN speed transition when
temperature approaching
temperature target upward or
downward. Select Hysteresis to
keep FAN at the same speed
within the range
Default Fan PWM
40%
60%
80%
100%
Comments
Select CPU FAN default PWM
according to altitude under Auto
mode
Select Default FAN PWM to make
FAN speed keep the invariable
speed when temperature is below
FSC temperature target at low
customized conditions. This
delivers optimized acoustic level
The change can
not take effect
immediately by
increasing the
PWM. It requires
a power cycle or
a thermal event
to take the
change in effect.
Note: the two options of Hysteresis and Default Fan PWM apply to all the four Fans
5.1.4
Voltage and Temperature Status Screen
Display monitored voltage, current Fan speed PWM and temperature
Server Management


Real time Temperature and PWM:
CPU Fan PWM
System Fan PWM
System temperature
Voltage status:
+Vccp
+12V
+3.3V
+5.0V
+1.5V
+1.05V
+3.3V(standby)
Figure 17. Setup Utility — Voltage and Temperature Status Screen
Table 15. Setup Utility — Voltage and Temperature Status Fields
44
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS
5.2
Server Management Capability for Intel® Server Board S3420GPV
Setup Item
CPU Fan PWM
Comments
Get and display CPU fan PWM periodically
System Fan PWM
Get and display system fan PWM periodically
System temperature
Get and display current system temperature
monitored by system sensor
+Vccp
Get and display +Vccp voltage periodically
+12V
Get and display +12 voltage periodically
+3.3V
Get and display +3.3 voltage periodically
+5.0V
Get and display +5.0V voltage periodically
+1.5V
Get and display +1.5V voltage periodically
+1.05V
Get and display +1.05 voltage periodically
+3.3V(standby)
Get and display +3.3V(standby)voltage periodically
SMBIOS
5.2.1
Data Storage
®
On Intel Server Board S3420GPLX and Intel® Server Board S3420GPLC with iBMC, the
SMBIOS type 1, 2, 3 are from FRUSDR by BMC. But on Intel® Server Board S3420GPV,
SMBIOS type 1, 2, 3 are stored in BIOS flash during manufactory build, so it’s also non-volatile
data storage.
BIOS retrieve the SMBIOS data from flash during POST, and it builds the SMBIOS type 1, 2, 3
into SMBIOS table and then transfers the control to operating system. Operating system and
system management software can use the SMBIOS table for system management purpose.
5.3
Event log and Viewer
5.3.1
Event Log Viewer in Setup
®
On Intel Server Board S3420GPLX and Intel® Server Board S3420GPLC, there is a dedicated
utility to view the event log. There is no IPMI support - the way to view the event log in BIOS
Setup, on Intel® Server Board S3420GPV.
There is one page in BIOS setup for event log viewer. It is located in Error Manager Page.
Revision 2.4
Intel order number E65697-010
45
Server Management Capability for Intel® Server Board S3420GPV
Intel® Server Board S3420GP TPS

Error Manager

No.
005
Event Info
M-BIT MEM ECC Error CPU0 Ch 0 Dimm0
Time
10/15/09 15:12:23
004
S-BIT MEM ECC Error CPU0 Ch 0 Dimm0
10/15/09 15:11:25
003
PCIE UNCOR ERR Bus0 Dev 1C Fun0
10/15/09 15:08:36
002
MEM Parity Error CPU0 Ch 0 Dimm0
10/15/09 15:07:11
001
Thermal Trip Occurred.
10/15/09 15:05:05
Figure 18. Event Log Viewer
The Event log viewer is at another page than the BIOS error manager. The event log viewer can
display many log in one page. Each event log is displayed in one line. The latest one is on the
top. When there are more event logs on one page, Page Up and Page Down keys can be used.
There is a scroll bar to allow end-users to view the logs from top to bottom.
46
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS
6.
6.1
BIOS User Interface
BIOS User Interface
Logo/Diagnostic Screen
The logo/Diagnostic Screen displays in one of two forms:

If Quiet Boot is enabled in the BIOS setup, a logo splash screen displays. By default,
Quiet Boot is enabled in the BIOS setup. If the logo displays during POST, press <Esc>
to hide the logo and display the diagnostic screen.

If a logo is not present in the flash ROM or if Quiet Boot is disabled in the system
configuration, the summary and diagnostic screen displays.
The diagnostic screen displays the following information:

BIOS ID

Platform name

Total memory detected (Total size of all installed DDR3 DIMMs)

Processor information (Intel branded string, speed, and number of physical processor
identified)

Keyboards detected (if plugged in)

Mouse devices detected (if plugged in)
6.2
BIOS Boot Popup Menu
The BIOS Boot Specification (BBS) provides for a Boot Popup Menu invoked by pressing the
<F6> key during POST. The BBS popup menu displays all available boot devices. The list order
in the popup menu is not the same as the boot order in the BIOS setup; it simply lists the
bootable devices from which the system can be booted.
When a User Password or Administrator Password is active in Setup, the password is to access
the Boot Popup Menu.
6.3
BIOS Setup utility
The BIOS setup utility is a text-based utility that allows the user to configure the system and
view current settings and environment information for the platform devices. The Setup utility
controls the platform’s built-in devices, boot manager, and error manager.
The BIOS setup interface consists of a number of pages or screens. Each page contains
information or links to other pages. The advanced tab in Setup displays a list of general
categories as links. These links lead to pages containing a specific category’s configuration.
The following sections describe the look and behavior for platform setup.
Revision 2.4
Intel order number E65697-010
47
BIOS User Interface
6.3.1
Intel® Server Board S3420GP TPS
Operation
The BIOS Setup has the following features:

Localization - The BIOS Setup uses the Unicode standard and is capable of displaying
setup forms in all languages currently included in the Unicode standard. The Intel®
server board BIOS is only available in English.

Console Redirection - The BIOS Setup is functional through console redirection over
various terminal emulation standards. This may limit some functionality for compatibility
(for example, color usage or some keys or key sequences or support of pointing
devices).
6.3.1.1
Setup Page Layout
The setup page layout is sectioned into functional areas. Each occupies a specific area of the
screen and has dedicated functionality. The following table lists and describes each functional
area.
Table 16. BIOS Setup Page Layout
Functional Area
Title Bar
Setup Item List
Item Specific Help Area
Keyboard Command Bar
6.3.1.2
Description
The title bar is located at the top of the screen and displays the title of the form
(page) the user is currently viewing. It may also display navigational information.
The Setup Item List is a set of controllable and informational items. Each item in the
list occupies the left column of the screen.
A Setup Item may also open a new window with more options for that functionality
on the board.
The Item Specific Help area is located on the right side of the screen and contains
help text for the highlighted Setup Item. Help information may include the meaning
and usage of the item, allowable values, effects of the options, and so forth.
The Keyboard Command Bar is located at the bottom right of the screen and
continuously displays help for keyboard special keys and navigation keys.
Entering BIOS Setup
To enter the BIOS Setup, press the F2 function key during boot time when the OEM or Intel logo
displays. The following message displays on the diagnostics screen and under the Quiet Boot
logo screen:
Press <F2> to enter setup
When the Setup is entered, the Main screen displays. However, serious errors cause the
system to display the Error Manager screen instead of the Main screen.
6.3.1.3
Keyboard Commands
The bottom right portion of the Setup screen provides a list of commands used to navigate
through the Setup utility. These commands display at all times.
Each Setup menu page contains a number of features. Each feature is associated with a value
field except those used for informative purposes. Each value field contains configurable
parameters. Depending on the security option chosen and, in effect, by the password, a menu
48
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS
BIOS User Interface
feature’s value may or may not be changed. If a value cannot be changed, its field is made
inaccessible and appears grayed out.
Table 17. BIOS Setup: Keyboard Command Bar
Key
<Enter>
Option
Execute
Command
Description
The <Enter> key is used to activate sub-menus when the selected feature is a submenu, or to display a pick list if a selected option has a value field, or to select a
sub-field for multi-valued features like time and date. If a pick list is displayed, the
<Enter> key selects the currently highlighted item, undoes the pick list, and returns
the focus to the parent menu.
<Esc>
Exit

Select Item
The <Esc> key provides a mechanism for backing out of any field. When the <Esc>
key is pressed while editing any field or selecting features of a menu, the parent
menu is re-entered.
When the <Esc> key is pressed in any sub-menu, the parent menu is re-entered.
When the <Esc> key is pressed in any major menu, the exit confirmation window is
displayed and the user is asked whether changes can be discarded. If “No” is
selected and the <Enter> key is pressed, or if the <Esc> key is pressed, the user is
returned to where they were before <Esc> was pressed, without affecting any
existing settings. If “Yes” is selected and the <Enter> key is pressed, the setup is
exited and the BIOS returns to the main System Options Menu screen.
The up arrow is used to select the previous value in a pick list, or the previous
option in a menu item's option list. The selected item must then be activated by
pressing the <Enter> key.

Select Item
The down arrow is used to select the next value in a menu item’s option list, or a
value field’s pick list. The selected item must then be activated by pressing the
<Enter> key.

Select Menu
The left and right arrow keys are used to move between the major menu pages.
The keys have no affect if a sub-menu or pick list is displayed.
<Tab>
Select Field
The <Tab> key is used to move between fields. For example, <Tab> can be used
to move from hours to minutes in the time item in the main menu.
-
Change Value
+
Change Value
The minus key on the keypad is used to change the value of the current item to the
previous value. This key scrolls through the values in the associated pick list
without displaying the full list.
The plus key on the keypad is used to change the value of the current menu item
to the next value. This key scrolls through the values in the associated pick list
without displaying the full list. On 106-key Japanese keyboards, the plus key has a
different scan code than the plus key on the other keyboards, but will have the
same effect.
<F9>
Setup Defaults
Pressing <F9> causes the following to display:
Load Optimized Defaults?
Yes
No
If “Yes” is highlighted and <Enter> is pressed, all Setup fields are set to their
default values. If “No” is highlighted and <Enter> is pressed, or if the <Esc> key is
pressed, the user is returned to where they were before <F9> was pressed without
affecting any existing field values.
Revision 2.4
Intel order number E65697-010
49
BIOS User Interface
Key
<F10>
Option
Save and Exit
Intel® Server Board S3420GP TPS
Description
Pressing <F10> causes the following message to display:
Save configuration and reset?
Yes
No
If “Yes” is highlighted and <Enter> is pressed, all changes are saved and the Setup
is exited. If “No” is highlighted and <Enter> is pressed, or the <Esc> key is
pressed, the user is returned to where they were before <F10> was pressed
without affecting any existing values.
6.3.1.4
Menu Selection Bar
The Menu Selection Bar is located at the top of the BIOS Setup Utility screen. It displays the
major menu selections available to the user. By using the left and right arrow keys, the user can
select the menus listed here. Some menus are hidden and become available by scrolling off the
left or right of the current selections.
6.3.2
Server Platform Setup Utility Screens
The following sections describe the screens available for the configuration of a server platform.
In these sections, tables are used to describe the contents of each screen. These tables follow
the following guidelines:

The Setup Item, Options, and Help Text columns in the tables document the text and
values displayed on the BIOS Setup screens.

In the Options column, the default values display in bold. These values are not displayed
in bold on the BIOS Setup screen; the bold text in this document serves as a reference
point.

The Comments column provides additional information where it may be helpful. This
information does not display on the BIOS Setup screens.

Information enclosed in angular brackets (< >) in the screen shots identifies text that can
vary, depending on the option(s) installed. For example, <Current Date> is replaced by
the actual current date.

Information enclosed in square brackets ([ ]) in the tables identifies areas where the user
must type in text instead of selecting from a provided option.

Whenever information is changed (except Date and Time), the system requires a save
and reboot to take place. Pressing <ESC> discards the changes and boots the system
according to the boot order set from the last boot.
6.3.2.1
Main Screen
The Main screen is the first screen displayed when the BIOS Setup is entered, unless an error
occurred. If an error occurred, the Error Manager screen displays instead.
50
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS

Main
Advance
d
Security
BIOS User Interface
Server Management
Boot Options
Boot Manager


Logged in as <Administrator or User>
<Platform Identification String>
Platform ID

System BIOS 
Version
SXXXX.86B.xx.yy.zzzz
Build Date
<MM/DD/YYYY>

 Memory

Total Memory
<How much memory is installed>

Quiet Boot
Enabled/Disabled
POST Error Pause
Enabled/Disabled

System Date
<Current Date>
System Time
<Current Time>

Figure 19. Setup Utility – Main Screen Display
Table 18. Setup Utility – Main Screen Fields
Setup Item
Logged in as
Options
Help Text
Platform ID
Comments
Information only. Displays
password level that setup is
running in: Administrator or User.
With no passwords set,
Administrator is the default mode.
Information only. Displays the
Platform ID.
LX SKU: S3420GPX
LC SKU: S3420GPC
V SKU: S3420GPV
System BIOS
Information only. Displays the
current BIOS version.
xx = major version
yy = minor version
zzzz = build number
Information only. Displays the
current BIOS build date.
Version
Build Date
Memory
Revision 2.4
Intel order number E65697-010
51
BIOS User Interface
Setup Item
Intel® Server Board S3420GP TPS
Options
Help Text
Size
Quiet Boot
Enabled
Disabled
Comments
Information only. Displays the
total physical memory installed in
the system, in MB or GB. The term
physical memory indicates the total
memory discovered in the form of
installed DDR3 DIMMs.
[Enabled] – Display the logo screen
during POST.
[Disabled] – Display the diagnostic
screen during POST.
POST Error Pause
Enabled
Disabled
[Enabled] – Go to the Error
Manager for critical POST errors.
[Disabled] – Attempt to boot and do
not go to the Error Manager for
critical POST errors.
System Date
[Day of week
MM/DD/YYYY]
System Date has configurable
fields for Month, Day, and Year.
Use [Enter] or [Tab] key to select
the next field.
Use [+] or [-] key to modify the
selected field.
System Time
[HH:MM:SS]
System Time has configurable
fields for Hours, Minutes, and
Seconds.
Hours are in 24-hour format.
Use [Enter] or [Tab] key to select
the next field.
Use [+] or [-] key to modify the
selected field.
6.3.2.2
If enabled, the POST Error Pause
option takes the system to the error
manager to review the errors when
major errors occur. Minor and fatal
error displays are not affected by
this setting.
Advanced Screen
The Advanced screen provides an access point to configure several options. On this screen,
the user selects the option they want to configure. Configurations are performed on the selected
screen, and not directly on the Advanced screen.
To access this screen from the Main screen, press the right arrow until the Advanced screen is
chosen.
52
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS
Main
Advance
d
Security
BIOS User Interface
Server Management
Boot Options
Boot Manager

► Processor Configuration
► Memory Configuration
► Mass Storage Controller Configuration
► Serial Port Configuration
► USB Configuration
► PCI Configuration
► System Acoustic and Performance Configuration

Figure 20. Setup Utility – Advanced Screen Display
Table 19. Setup Utility – Advanced Screen Display Fields
6.3.2.2.1
Setup Item
Processor Configuration
Help Text
View/Configure processor information and
settings.
Memory Configuration
View/Configure memory information and
settings.
Mass Storage Controller Configuration
View/Configure mass storage controller
information and settings.
Serial Port Configuration
View/Configure serial port information and
settings.
USB Configuration
View/Configure USB information and
settings.
PCI Configuration
View/Configure PCI information and
settings.
System Acoustic and Performance
Configuration
View/Configure system acoustic and
performance information and settings.
Processor Screen
The Processor screen allows the user to view the processor core frequency, system bus
frequency, and to enable or disable several processor options. This screen also allows the user
to view information about a specific processor.
To access this screen from the Main screen, select Advanced > Processor.
Revision 2.4
Intel order number E65697-010
53
BIOS User Interface
Intel® Server Board S3420GP TPS
Advanced
Processor Configuration
Processor Socket
Processor ID
Processor Frequency
Microcode Revision
L1 Cache RAM
L2 Cache RAM
L3 Cache RAM
CPU 1
<CPUID>
<Proc Freq>
<Rev data>
Size of Cache
Size of Cache
Size of Cache
Processor 1 Version
<ID string from Processor 1>
Current QPI Link Speed
QPI Link Frequency
Intel® Turbo Boost Technology
<Slow/Fast >
<Unknown GT/s/4.8 GT/s/5.866 GT/s/6.4 GT/s>
Enabled/Disabled
Enhanced Intel SpeedStep® Tech
Enabled/Disabled
Processor C3 Report
Processor C6 Report
Intel® Hyper-Threading Technology
Core Multi-Processing
Execute Disable Bit
Intel® Virtualization Technology
Intel® VT for Directed I/O
Pass-through DMA Support
Hardware Prefetcher
Adjacent Cache Line Prefetch
Enabled/ Disabled
Enabled/ Disabled
Enabled/Disabled
All/1/2
Enabled/Disabled
Enabled/ Disabled
Enabled/ Disabled
Enabled/Disabled
Enabled/Disabled
Enabled/Disabled
Figure 21. Setup Utility – Processor Configuration Screen Display
Table 20. Setup Utility – Processor Configuration Screen Fields
Setup Item
Processor ID
Options
Help Text
Processor Frequency
Core Frequency
Microcode Revision
L1 Cache RAM
54
Intel order number E65697-010
Comments
Information only. Processor
CPUID.
Information only. Current
frequency of the processor.
Information only. Frequency
at which the processor are
currently running.
Information only. Revision of
the loaded microcode.
Information only. Size of the
Processor L1 Cache.
Revision 2.4
Intel® Server Board S3420GP TPS
Setup Item
L2 Cache RAM
BIOS User Interface
Options
Help Text
Comments
Information only. Size of the
Processor L2 Cache
Information only. Size of the
Processor L3 Cache.
Information only. ID string
from the Processor.
L3 Cache RAM
Processor Version
Information only. Current
speed that the QPI Link is
using.
Information only. Current
frequency that the QPI Link is
using.
Current QPI Link Speed
QPI Link Frequency
®
®
Intel Turbo Boost
Technology
Enabled
Disabled
Intel Turbo Boost Technology allows the
processor to automatically increase its
frequency if it is running below power,
temperature, and current specifications.
Enhanced Intel
®
SpeedStep Technology
Enabled
Disabled
Enhanced Intel SpeedStep Technology
allows the system to dynamically adjust
processor voltage and core frequency, which
can result in decreased average power
consumption and decreased average heat
production.
Contact your OS vendor regarding OS
support of this feature.
Intel Hyper-Threading
Technology
Enabled
Disabled
Intel HT Technology allows multithreaded
software applications to execute threads in
parallel within the processor.
Contact your OS vendor regarding OS
support of this feature.
Core Multi-Processing
All
1
2
Enabled
Disabled
Enable 1, 2 or All cores of installed
processor packages.
®
Execute Disable Bit
®
Intel Virtualization
Technology
Enabled
Disabled
®
®
Execute Disable Bit can help prevent certain
classes of malicious buffer overflow attacks.
Contact your OS vendor regarding OS
support of this feature.
®
Intel Virtualization Technology allows a
platform to run multiple operating systems
and applications in independent partitions.
Note: A change to this option requires the
system to be powered off and then back on
before the setting takes effect.
®
Enabled
Disabled
Enable/Disable Intel Virtualization
Technology for Directed I/O.
Report the I/O device assignment to VMM
through DMAR ACPI Tables
Pass-through DMA
Support
Enabled
Disabled
Enable/Disable Intel VT-d Pass-through
DMA support.
Hardware Prefetcher
Enabled
Disabled
Hardware Prefetcher is a speculative
prefetch unit within the processor(s).
Note: Modifying this setting may affect
system performance.
®
Intel Virtualization
Technology for Directed
I/O
Revision 2.4
This option is only visible if all
processor in the system
®
support Intel Turbo Boost
Technology.
®
Intel order number E65697-010
®
Only visible when Intel
Virtualization Technology for
Directed I/O is enabled.
55
BIOS User Interface
Intel® Server Board S3420GP TPS
Setup Item
Adjacent Cache Line
Prefetch
6.3.2.2.2
Options
Enabled
Disabled
Help Text
[Enabled] - Cache lines are fetched in pairs
(even line + odd line).
[Disabled] - Only the current cache line
required is fetched.
Note: Modifying this setting may affect
system performance.
Comments
Memory Screen
The Memory screen allows the user to view details about the system memory DDR3 DIMMs
installed. This screen also allows the user to open the Configure Memory RAS and Performance
screen.
To access this screen from the Main screen, select Advanced > Memory.
Advanced
Memory Configuration
Total Memory
Effective Memory
Current Configuration
Current Memory Speed
►
DIMM Information
DIMM_A1
DIMM_A2
DIMM_A3
DIMM_B1
DIMM_B2
DIMM_B3
<Total Physical Memory Installed in System>
<Total Effective Memory>
<Independent >
<Speed that installed memory is running at.>
Installed/Not Installed/Failed/Disabled/Spare Unit
Installed/Not Installed/Failed/Disabled/Spare Unit
Installed/Not Installed/Failed/Disabled/Spare Unit
Installed/Not Installed/Failed/Disabled/Spare Unit
Installed/Not Installed/Failed/Disabled/Spare Unit
Installed/Not Installed/Failed/Disabled/Spare Unit
Figure 22. Setup Utility – Memory Configuration Screen Display
Table 21. Setup Utility – Memory Configuration Screen Fields
Setup Item
Total Memory
56
Comments
Information only. The amount of memory available in the system
in the form of installed DDR3 DIMMs in units of MB or GB.
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS
Setup Item
Effective Memory
Current Configuration
6.3.2.2.3
BIOS User Interface
Comments
Information only. The amount of memory available to the
operating system in MB or GB.
The Effective Memory is the difference between the Total Physical
Memory and the sum of all memory reserved for internal usage,
RAS redundancy and SMRAM. This difference includes the sum of
all DDR3 DIMMs that failed Memory BIST during POST, or were
disabled by the BIOS during memory discovery phase to optimize
memory configuration.
Information only. Displays one of the following:
Independent Mode: System memory is configured for optimal
performance and efficiency and no RAS is enabled.
Sparing Mode: System memory is configured for RAS with
optimal effective memory.
Current Memory
Speed
Information only. Displays the speed the memory is running at.
DIMM_ XY
Displays the state of each DIMM socket present on the board.
Each DIMM socket field reflects one of the following possible
states:
Installed: There is a DDR3 DIMM installed in this slot.
Not Installed: There is no DDR3 DIMM installed in this slot.
Disabled: The DDR3 DIMM installed in this slot was disabled by
the BIOS to optimize memory configuration.
Failed: The DDR3 DIMM installed in this slot is
faulty/malfunctioning.
Spare Unit: The DDR3 DIMM is functioning as a spare unit for
memory RAS purposes.
Note: X denotes the Channel Identifier and Y denote the DIMM
Identifier within the Channel.
Mass Storage Controller Screen
The Mass Storage screen allows the user to configure the SATA/SAS controller when it is
present on the baseboard, midplane, or backplane of an Intel system.
To access this screen from the Main menu, select Advanced > Mass Storage.
Revision 2.4
Intel order number E65697-010
57
BIOS User Interface
Intel® Server Board S3420GP TPS
Advanced
Mass Storage Controller Configuration
Intel® Entry SAS RAID Module
Configure Intel® Entry SAS RAID Module
Onboard SATA Controller
Configure SATA Mode
Enabled/Disabled
LSI ® Integrated RAID/Intel® ESRTII
Enabled/Disabled
ENHANCED/COMPATIBILITY/AHCI/SW RAID
► SATA Port 0
Not Installed/<Drive Info.>
► SATA Port 1
Not Installed/<Drive Info.>
► SATA Port 2
Not Installed/<Drive Info.>
► SATA Port 3
Not Installed/<Drive Info.>
► SATA Port 4
Not Installed/<Drive Info.>
► SATA Port 5
Not Installed/<Drive Info.>
Figure 23. Setup Utility – Mass Storage Controller Configuration Screen Display
Table 22. Setup Utility – Mass Storage Controller Configuration Screen Fields
Setup Item
®
Intel Entry SAS RAID
Module
®
Options
Help Text
Comments
Unavailable if the SAS Module
®
Enabled or Disable the Intel SAS (AXX4SASMOD) is not present.
Entry RAID Module
Note: This option is not
available on some models.
Enabled
Disabled
®
®
Configure Intel Entry
SAS RAID Module
LSI Integrated
RAID
®
Intel ESRTII
LSI Integrated RAID - Supports
RAID 0, RAID 1, and RAID 1e, as
well as IT (JBOD) mode;
®
®
Intel ESRTII - Intel Embedded
Server RAID Technology II, which
supports RAID 0, RAID 1, RAID
10.
Onboard SATA
Controller
Enabled
Disabled
Onboard Serial ATA (SATA)
controller.
SATA Mode
ENHANCED
COMPATIBILITY
AHCI
Intel ESRT2
Matrix RAID
[ENHANCED] - Supports up to 6
SATA ports with IDE Native
Mode.
[COMPATIBILITY] - Supports up
to 4 SATA ports[0/1/2/3] with IDE
Legacy mode and 2 SATA
ports[4/5] with IDE Native Mode.
[AHCI] - Supports all SATA ports
using the Advanced Host
Controller Interface.
[Intel ESRT2] - Supports RAID
®
0/1/10 with Intel Embedded
Software RAIDII Technology.
[Matrix RAID] – Supports RAID
®
levels 0/1/10 and 5 with Intel
Matrix Storage RAID Technology.
58
Intel order number E65697-010
Unavailable if the SAS Module
(AXX4SASMOD) is disabled or
not present
Note: This option is not
available on some models.
Disappears when the Onboard
SATA Controller is disabled.
Revision 2.4
Intel® Server Board S3420GP TPS
BIOS User Interface
Setup Item
SATA Port 0
Options
< Not
Installed/Drive
information>
SATA Port 1
< Not
Installed/Drive
information>
< Not
Installed/Drive
information>
SATA Port 2
SATA Port 3
< Not
Installed/Drive
information>
SATA Port 4
< Not
Installed/Drive
information>
< Not
Installed/Drive
information>
SATA Port 5
6.3.2.2.4
Help Text
Comments
Information only. This field is
unavailable when RAID Mode is
enabled.
Information only. This field is
unavailable when RAID Mode is
enabled.
Information only. This field is
unavailable when RAID Mode is
enabled.
Information only. This field is
unavailable when RAID Mode is
enabled.
Information only. This field is
unavailable when RAID Mode is
enabled.
Information only. This field is
unavailable when RAID Mode is
enabled.
Serial Ports Screen
The Serial Ports screen allows the user to configure the Serial A [COM 1] and Serial B [COM2]
ports.
To access this screen from the Main screen, select Advanced > Serial Port.
Advanced
Serial Port Configuration

Serial A Enable
Enabled/Disabled
Address
3F8h/2F8h/3E8h/2E8h
IRQ
3 or 4
Serial B Enable
Enabled/Disabled
Address
3F8h/2F8h/3E8h/2E8h
IRQ
3 or 4



Figure 24. Setup Utility – Serial Port Configuration Screen Display
Table 23. Setup Utility – Serial Ports Configuration Screen Fields
Revision 2.4
Setup Item
Serial A
Enable
Options
Enabled
Disabled
Help Text
Enable or Disable Serial port A.
Address
3F8h
2F8h
3E8h
2E8h
Select Serial port A base I/O address.
Intel order number E65697-010
59
BIOS User Interface
Intel® Server Board S3420GP TPS
Setup Item
IRQ
6.3.2.2.5
Options
3
4
Help Text
Select Serial port A interrupt request (IRQ) line.
Serial B
Enable
Enabled
Disabled
Enable or Disable Serial port B.
Address
3F8h
2F8h
3E8h
2E8h
Select Serial port B base I/O address.
IRQ
3
4
Select Serial port B interrupt request (IRQ).
USB Configuration Screen
The USB Configuration screen allows the user to configure the USB controller options.
To access this screen from the Main screen, select Advanced > USB Configuration.
Advanced
USB Configuration
Detected USB Devices
<Total USB Devices in System>
USB Controller
Legacy USB Support
Port 60/64 Emulation
Make USB Devices Non-Bootable
Enabled/Disabled
Enabled/Disabled/Auto
Enabled/Disabled
Enabled/Disabled
USB Mass Storage Device Configuration
Device Reset timeout
10 seconds/20 seconds/30 seconds/40 seconds
Mass Storage Devices:
<Mass storage devices one line/device>
Auto/Floppy/Forced FDD/Hard Disk/CD-ROM
USB 2.0 controller
Enabled/Disabled
Figure 25. Setup Utility – USB Controller Configuration Screen Display
60
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS
BIOS User Interface
Table 24. Setup Utility – USB Controller Configuration Screen Fields
Setup Item
Detected USB
Devices
Options
Help Text
Comments
Information only. Shows the number
of USB devices in the system.
USB Controller
Enabled
Disabled
[Enabled] - All onboard USB controllers are turned on and
accessible by the OS.
[Disabled] - All onboard USB controllers are turned off and
inaccessible by the OS.
Legacy USB
Support
Enabled
Disabled
Auto
USB device boot support and PS/2 emulation for USB
keyboard and USB mouse devices.
[Auto] - Legacy USB support is enabled if a USB device is
attached.
Grayed out if the USB Controller is
disabled.
Port 60/64
Emulation
Enabled
Disabled
I/O port 60h/64h emulation support.
Note: This may be needed for legacy USB keyboard
support when using an OS that is USB unaware.
Grayed out if the USB Controller is
disabled.
Make USB
Devices NonBootable
Enabled
Disabled
Exclude USB in Boot Table.
[Enabled] - This removes all USB Mass Storage devices
as Boot options.
[Disabled] - This allows all USB Mass Storage devices as
Boot options.
Grayed out if the USB Controller is
disabled.
Device Reset
timeout
10 sec
20 sec
30 sec
40 sec
USB Mass Storage device Start Unit command timeout.
Setting to a larger value provides more time for a mass
storage device to be ready, if needed.
Grayed out if the USB Controller is
disabled.
One line for each
mass storage
device in system
Auto
Floppy
Forced FDD
Hard Disk
CD-ROM
[Auto] - USB devices less than 530 MB are emulated as
floppies.
[Forced FDD] - HDD formatted drive are emulated as a
FDD (e.g., ZIP drive).
USB 2.0
controller
Enabled
Disabled
Onboard USB ports are enabled to support USB 2.0
mode.
Contact your OS vendor regarding OS support of this
feature.
Hidden if no USB Mass storage
devices are installed.
Grayed out if the USB Controller is
disabled.
This setup screen can show a
maximum of eight devices on this
screen. If more than eight devices
are installed in the system, the USB
Devices Enabled shows the correct
count, but only displays the first
eight devices here.
Grayed out if the USB Controller is
disabled.
6.3.2.2.6
PCI Screen
The PCI Screen allows the user to configure the PCI add-in cards, onboard NIC controllers, and
video options.
To access this screen from the Main screen, select Advanced > PCI.
Revision 2.4
Intel order number E65697-010
61
BIOS User Interface


Intel® Server Board S3420GP TPS

Advanced
PCI Configuration
Maximize Memory below 4GB
Enabled/Disabled
Memory Mapped I/O above 4GB
Enabled/Disabled
Onboard Video
Enabled/Disabled
Dual Monitor Video
Enabled/Disabled
Onboard NIC1 ROM
Enabled/Disabled
Onboard NIC2 ROM
Enabled/Disabled
Onboard NIC iSCSI ROM
Enabled/Disabled
NIC 1 MAC Address
<MAC #>
NIC 2 MAC Address
<MAC #>
Figure 26. Setup Utility – PCI Configuration Screen Display
Table 25. Setup Utility – PCI Configuration Screen Fields
Setup Item
Maximize Memory
below 4GB
Options
Enabled
Disabled
Help Text
If enabled. the BIOS maximizes usage of memory
below 4 GB for OS without PAE by limiting PCIE
Extended Configuration Space to 64 buses.
Enable or disable memory mapped I/O of 64-bit
PCI devices to 4 GB or greater address space.
Comments
Memory Mapped I/O
above 4GB
Enabled
Disabled
Onboard Video
Enabled
Disabled
Onboard video controller.
Warning: System video is completely disabled if
this option is disabled and an add-in video
adapter is not installed.
Dual Monitor Video
Enabled
Disabled
Onboard NIC1 ROM
Enabled
Disabled
Onboard NIC2 ROM
Enabled
Disabled
If enabled. both the onboard video controller and
an add-in video adapter are enabled for system
video. The onboard video controller becomes the
primary video device.
If enabled. loads the embedded option ROM for
the onboard network controllers.
Warning: If [Disabled] is selected, NIC1 cannot
be used to boot or wake the system.
If enabled. loads the embedded option ROM for
the onboard network controllers.
Warning: If [Disabled] is selected, NIC2 cannot
be used to boot or wake the system.
When disabled, the system
requires an add-in video
card for the video to be
seen.
Note: This option is not
available on some models.
Note: This option does not
appear on some models.
62
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS
Setup Item
Onboard NIC iSCSI
ROM
Options
Enabled
Disabled
NIC 1 MAC Address
No entry
allowed
No entry
allowed
NIC 2 MAC Address
6.3.2.2.7
BIOS User Interface
Help Text
If enabled. loads the embedded option ROM for
the onboard network controllers.
Comments
This option is grayed out
and not accessible if either
the NIC1 or NIC2 ROMs
Warning: If [Disabled] is selected, NIC1 and NIC2 are enabled.
Note: This option is not
cannot be used to boot or wake the system.
available on some models.
Information only. 12 hex
digits of the MAC address.
Information only. 12 hex
digits of the MAC address.
System Acoustic and Performance Configuration
The System Acoustic and Performance Configuration screen allows the user to configure the
thermal characteristics of the system.
To access this screen from the Main screen, select Advanced > System Acoustic and
Performance Configuration.

Advanced

System Acoustic and Performance Configuration
Set Throttling Mode
Auto/CLTT/OLTT
Altitude
300m or less/301m-900m/901m – 1500m/Higher than 1500m
Set Fan Profile
Performance, Acoustic
Figure 27. Setup Utility – System Acoustic and Performance Configuration Screen Display
Table 26. Setup Utility – System Acoustic and Performance Configuration Screen Fields
Setup Item
Set Throttling
Mode
Revision 2.4
Options
Auto
CLTT
OLTT
Help Text
[Auto] – Auto Throttling mode.
[CLTT] – Closed Loop Thermal Throttling Mode.
[OLTT] – Open Loop Thermal Throttling Mode.
Intel order number E65697-010
Comments
Note: The OLTT
option is shown for
informational
purposes only. If
the user selects
OLTT, the BIOS
overrides that
selection if the
system can support
CLTT. OLTT is
configured only when
UDIMMs without
Thermal Sensors are
installed.
63
BIOS User Interface
Intel® Server Board S3420GP TPS
Setup Item
Altitude
Options
300m or less
301m-900m
901m-1500m
Higher than 1500m
Help Text
[300m or less] (980ft or less)
Optimal performance setting near sea level.
[301m - 900m] (980ft - 2950ft)
Optimal performance setting at moderate elevation.
[901m – 1500m] (2950ft – 4920ft)
Optimal performance setting at high elevation.
[Higher than 1500m] (4920ft or greater)
Optimal performance setting at the highest elevations.
Comments
Note: This option is
not available on
some models.
Set Fan Profile
Performance
Acoustics
[Performance] - Fan control provides primary system
cooling before attempting to throttle memory.
[Acoustic] - The system will favor using throttling of
memory over boosting fans to cool the system if
thermal thresholds are met.
This option is grayed
out if CLTT is
enabled.
Note: This option is
not available on
some models.
6.3.2.3
Security Screen
The Security screen allows the user to enable and set the user and administrative password
and to lock out the front panel buttons so they cannot be used.
Trusted Platform Module (TPM) security is NOT supported on the Intel® Server S3420GP board.
To access this screen from the Main screen, select Security.

Main
Advanced
Security
Server Management
Boot Options
Administrator Password Status
<Installed/Not Installed>
User Password Status
<Installed/Not Installed>
Set Administrator Password
[1234aBcD]
Set User Password
[1234aBcD]
Front Panel Lockout
Enabled/Disabled
Boot Manager

Figure 28. Setup Utility – Security Configuration Screen Display
Table 27. Setup Utility – Security Configuration Screen Fields
Setup Item
Administrator Password
Status
64
Options
<Installed
Not Installed>
Help Text
Intel order number E65697-010
Comments
Information only. Indicates
the status of the
administrator password.
Revision 2.4
Intel® Server Board S3420GP TPS
Setup Item
User Password Status
Options
<Installed
Not Installed>
Set Administrator
Password
BIOS User Interface
Help Text
Comments
Information only. Indicates
the status of the user
password.
[123aBcD]
Administrator password is used to
control change access in BIOS Setup
Utility.
Only alphanumeric characters can be
used. Maximum length is 7 characters. It
is case sensitive.
Note: Administrator password must be
set in order to use the user account.
This option is only to control
access to the setup.
Administrator has full
access to all the setup
items. Clearing the
Administrator password
also clears the user
password.
Set User Password
[123aBcD]
User password is used to control entry
access to BIOS Setup Utility.
Only alphanumeric characters can be
used. Maximum length is 7 characters. It
is case sensitive.
Note: Removing the administrator
password also automatically removes
the user password.
Available only if the
administrator password is
installed. This option only
protects the setup.
User password only has
limited access to the setup
items.
Front Panel Lockout
Enabled
Disabled
If enabled, locks the power button and
reset button on the system's front panel.
If [Enabled] is selected, power and reset
must be controlled via a system
management interface.
6.3.2.4
Server Management Screen
The Server Management screen allows the user to configure several server management
features. This screen also provides an access point to the screens for configuring console
redirection and displaying system information.
To access this screen from the Main screen, select Server Management.
Revision 2.4
Intel order number E65697-010
65
BIOS User Interface

Main
Intel® Server Board S3420GP TPS
Advance
d
Security
Server Management
Boot Options
Boot Manager
Assert NMI on SERR
Enabled/Disabled
Assert NMI on PERR
Enabled/Disabled
Resume on AC Power Loss
Stay Off/Last state/Reset
Clear System Event Log
Enabled/Disabled
FRB-2 Enable
Enabled/Disabled
O/S Boot Watchdog Timer
Enabled/Disabled
O/S Boot Watchdog Timer Policy
Power off/Reset
O/S Boot Watchdog Timer Timeout
ACPI 1.0 Support
5 minutes/10 minutes/15 minutes/20 minutes
Enabled/Disabled
Plug & Play BMC Detection
Enabled/Disabled

► Console Redirection
► System Information
Figure 29. Setup Utility – Server Management Configuraiton Screen Display
Table 28. Setup Utility – Server Management Configuration Screen Fields
Setup Item
Assert NMI on SERR
Options
Enabled
Disabled
Help Text
On SERR, generate an NMI and log an error.
Note: [Enabled] must be selected for the Assert NMI
on PERR setup option to be visible.
Assert NMI on PERR
Enabled
Disabled
On PERR, generate an NMI and log an error.
Note: This option is only active if the Assert NMI on
SERR option is [Enabled] selected.
Resume on AC
Power Loss
Stay Off
Last state
Reset
System action to take on AC power loss recovery.
[Stay Off] - System stays off.
[Last State] - System returns to the same state before
the AC power loss.
[Reset] - System powers on.
Clear System Event
Log
Enabled
Disabled
If enabled, clears the System Event Log. All current
entries will be lost.
Note: This option is reset to [Disabled] after a reboot.
FRB-2 Enable
Enabled
Disabled
Fault Resilient Boot (FRB).
If enabled, the BIOS programs the BMC watchdog
timer for approximately 6 minutes. If the BIOS does
not complete POST before the timer expires, the BMC
resets the system.
66
Intel order number E65697-010
Comments
Revision 2.4
Intel® Server Board S3420GP TPS
BIOS User Interface
Setup Item
O/S Boot Watchdog
Timer
Options
Enabled
Disabled
Help Text
If enabled, the BIOS programs the watchdog timer
with the timeout value selected. If the OS does not
complete booting before the timer expires, the BMC
resets the system and an error is logged.
Requires OS support or Intel Management Software.
O/S Boot Watchdog
Timer Policy
Power Off
Reset
If the OS boot watchdog timer is enabled, this is the
system action taken if the watchdog timer expires.
[Reset] - System performs a reset.
[Power Off] - System powers off.
Grayed out when the O/S
Boot Watchdog Timer is
disabled.
O/S Boot Watchdog
Timer Timeout
5 minutes
10 minutes
15 minutes
20 minutes
If the OS watchdog timer is enabled, this is the
timeout value used by the BIOS to configure the
watchdog timer.
Grayed out when the O/S
Boot Watchdog Timer is
disabled.
Plug & Play BMC
Detection
Enabled
Disabled
If enabled, the BMC is detectable by OSs that support
plug and play loading of an IPMI driver. Do not enable
if your OS does not support this driver.
ACPI 1.0 Support
Enabled
Disabled
[Enabled] - Publish ACPI 1.0 version of FADT in Root
System Description Table.
This may be required for compatibility with OS
versions that only support ACPI 1.0.
Needs to be [Enabled] for
Microsoft Windows 2000*
support.
Console Redirection
View/Configure console redirection information and
settings.
Takes the user to the
Console Redirection
screen.
System Information
View system information
Takes the user to the
System Information
screen.
6.3.2.4.1
Comments
Console Redirection Screen
The Console Redirection screen allows the user to enable or disable console redirection and to
configure the connection options for this feature.
To access this screen from the Main screen, select Server Management > Console
Redirection.
Server Management


Console Redirection
Console Redirection
Disabled/Serial Port A/Serial Port B
Flow Control
None/RTS/CTS
Baud Rate
9.6k/19.2k/38.4k/57.6k/115.2k
Terminal Type
PC-ANSI/VT100/VT100+/VT-UTF8
Legacy OS Redirection
Disabled/Enabled
Figure 30. Setup Utility – Console Redirection Screen Display
Revision 2.4
Intel order number E65697-010
67
BIOS User Interface
Intel® Server Board S3420GP TPS
Table 29. Setup Utility – Console Redirection Configuration Fields
Setup Item
Console Redirection
Options
Disabled
Serial Port A
Serial Port B
Help Text
Console redirection allows a serial port to be used for server
management tasks.
[Disabled] - No console redirection.
[Serial Port A] - Configure serial port A for console redirection.
[Serial Port B] - Configure serial port B for console redirection.
Enabling this option disables the display of the Quiet Boot logo
screen during POST.
Flow Control
None
RTS/CTS
Flow control is the handshake protocol.
Setting must match the remote terminal application.
[None] - Configure for no flow control.
[RTS/CTS] - Configure for hardware flow control.
Baud Rate
9600
19.2K
38.4K
57.6K
115.2K
Serial port transmission speed. Setting must match the remote
terminal application.
Terminal Type
PC-ANSI
VT100
VT100+
VT-UTF8
Character formatting used for console redirection. Setting must
match the remote terminal application.
Legacy OS
Redirection
Disabled
Enabled
This option enables legacy OS redirection (i.e., DOS) on serial
port. If it is enabled, the associated serial port is hidden from the
legacy OS.
6.3.2.5
Server Management System Information Screen
The Server Management System Information screen allows the user to view part numbers,
serial numbers, and firmware revisions.
To access this screen from the Main screen, select Server Management > System
Information.
68
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS
BIOS User Interface
Server Management


System Information
Board Part Number
Board Serial Number
System Part Number
System Serial Number
Chassis Part Number
Chassis Serial Number
BMC Firmware Revision
HSC Firmware Revision
ME Firmware Revision
SDR Revision
UUID
Figure 31. Setup Utility – Server Management System Information Screen Display
Table 30. Setup Utility – Server Management System Information Fields
Setup Item
Board Part Number
6.3.2.6
Comments
Information only
Board Serial Number
Information only
System Part Number
System Serial Number
Chassis Part Number
Information only
Information only
Information only
Chassis Serial Number
Information only
BMC Firmware Revision
Information only
HSC Firmware Revision
ME Firmware Revision
Information only
Information only
SDR Revision
Information only
UUID
Information only
Boot Options Screen
The Boot Options screen displays any bootable media encountered during POST, and allows
the user to configure the preferred boot device.
To access this screen from the Main screen, select Boot Options.
Revision 2.4
Intel order number E65697-010
69
BIOS User Interface

Main
Intel® Server Board S3420GP TPS
Advance
d
Security
Server Management
Boot Options
System Boot Timeout
<0 - 65535>
Boot Option #1
<Available Boot devices>
Boot Option #2
<Available Boot devices>
Boot Option #x
<Available Boot devices>
Boot Manager

Hard Disk Order
CDROM Order
Network Device Order
►Delete Boot Option
EFI Optimized Boot
Enabled/Disabled
Boot Option Retry
Enabled/Disabled
Figure 32. Setup Utility – Boot Options Screen Display
Table 31. Setup Utility – Boot Options Screen Fields
Setup Item
Boot Timeout
Options
0 - 65535
Help Text
The number of seconds the BIOS
should pause at the end of POST to
allow the user to press the [F2] key for
entering the BIOS Setup utility.
Valid values are 0-65535. Zero is the
default. A value of 65535 causes the
system to go to the Boot Manager
menu and wait for user input for every
system boot.
Boot Option #x
Available boot
devices.
Set system boot order by selecting the
boot option for this position.
Comments
After entering the preferred
timeout, press the Enter key
to register that timeout value
to the system. These
settings are in seconds.
Hard Disk Order
Set the order of the legacy devices in
this group.
Visible when one or more
hard disk drives are in the
system.
CDROM Order
Set the order of the legacy devices in
this group.
Visible when one or more
CD-ROM drives are in the
system.
Floppy Order
Set the order of the legacy devices in
this group.
Visible when one or more
floppy drives are in the
system.
Network Device Order
Set the order of the legacy devices in
Visible when one or more of
70
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS
Setup Item
BIOS User Interface
Options
Help Text
this group.
BEV Device Order
Set the order of the legacy devices in
this group.
Add New Boot Option
Add a new EFI boot option to the boot
order.
Delete Boot Option
Remove an EFI boot option from the
boot order.
EFI Optimized Boot
Enabled
Disabled
If enabled, the BIOS only loads
modules required for booting EFIaware Operating Systems.
Boot Option Retry
Enabled
Disabled
If enabled, this continually retries nonEFI-based boot options without
waiting for user input.
Comments
these devices are available
in the system.
Visible when one or more of
these devices are available
in the system.
This option is only visible if
an EFI bootable device is
available to the system (for
example, a USB drive).
If the EFI shell is deleted,
you can restore it by setting
CMOS defaults (F9).
If all types of bootable devices are installed in the system, the default boot order is:
1.
2.
3.
4.
5.
6.
CD/DVD-ROM
Floppy Disk Drive
Hard Disk Drive
PXE Network Device
BEV (Boot Entry Vector) Device
EFI Shell and EFI Boot paths
6.3.2.6.1
Delete Boot Option Screen
The Delete Boot Option screen allows the user to remove an EFI boot option from the boot
order.
To access this screen from the Main screen, select Boot Options > Delete Boot Options.
Boot Options


Delete Boot Option
Delete Boot Option
Select one to Delete/Internal EFI Shell
Figure 33. Setup Utility – Delete Boot Option Screen Display
Revision 2.4
Intel order number E65697-010
71
BIOS User Interface
Intel® Server Board S3420GP TPS
Table 32. Setup Utility – Delete Boot Option Fields
Setup Item
Delete Boot Option
6.3.2.6.2
Options
Select one to Delete
Internal EFI Shell
Help Text
Remove an EFI boot option from the
boot order.
Hard Disk Order Screen
The Hard Disk Order screen allows the user to control the hard disks.
To access this screen from the Main screen, choose Boot Options > Hard Disk Order.
Boot Options

Hard Disk #1
< Available Hard Disks >
Hard Disk #2
< Available Hard Disks >

Figure 34. Setup Utility — Hard Disk Order Screen Display
Table 33. Setup Utility — Hard Disk Order Fields
Setup Item
Hard Disk #1
Hard Disk #2
6.3.2.6.3
Options
Available
Legacy devices
for this Device
group.
Available
Legacy devices
for this Device
group.
Help Text
Set system boot order by selecting the boot
option for this position.
Set system boot order by selecting the boot
option for this position.
CDROM Order Screen
The CDROM Order screen allows the user to control the CDROM devices.
To access this screen from the Main screen, select Boot Options > CDROM Order.
Boot Options

CDROM #1
CDROM #2

<Available CDROM devices>
<Available CDROM devices>
Figure 35. Setup Utility – CDROM Order Screen Display
72
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS
BIOS User Interface
Table 34. Setup Utility – CDROM Order Fields
6.3.2.6.4
Setup Item
CDROM #1
Options
Available
Legacy devices
for this Device
group.
Help Text
Set system boot order by selecting the boot
option for this position.
CDROM #2
Available
Legacy devices
for this Device
group.
Set system boot order by selecting the boot
option for this position.
Floppy Order Screen
The Floppy Order screen allows the user to control the floppy drives.
To access this screen from the Main screen, choose Boot Options > Floppy Order.
Boot Options

Floppy Disk #1
Floppy Disk #2

<Available Floppy Disk >
<Available Floppy Disk >
Figure 36. Setup Utility — Floppy Order Screen Display
Table 35. Setup Utility — Floppy Order Fields
6.3.2.6.5
Setup Item
Floppy Disk #1
Options
Available
Legacy devices
for this Device
group.
Help Text
Set system boot order by selecting the boot
option for this position.
Floppy Disk #2
Available
Legacy devices
for this Device
group.
Set system boot order by selecting the boot
option for this position.
Network Device Order Screen
The Network Device Order screen allows the user to control the network bootable devices.
To access this screen from the Main screen, select Boot Options > Network Device Order.
Boot Options

Network Device #1
Network Device #2

<Available Network devices>
<Available Network devices>
Figure 37. Setup Utility – Network Device Order Screen Display
Revision 2.4
Intel order number E65697-010
73
BIOS User Interface
Intel® Server Board S3420GP TPS
Table 36. Setup Utility – Network Device Order Fields
6.3.2.7
Setup Item
Network Device #1
Options
Available
Legacy devices
for this Device
group.
Help Text
Set system boot order by selecting the boot
option for this position.
Network Device #2
Available
Legacy devices
for this Device
group.
Set system boot order by selecting the boot
option for this position.
Boot Manager Screen
The Boot Manager screen allows the user to view a list of devices available for booting, and to
select a boot device for immediately booting the system.
To access this screen from the Main screen, select Boot Manager.
Main
Advance
d
Security
Server Management
Boot Options
Boot Manager
[Internal EFI Shell]

<Boot device #1>
<Boot Option #x>

Figure 38. Setup Utility – Boot Manager Screen Display
Table 37. Setup Utility – Boot Manager Screen Fields
6.4
Setup Item
Internal EFI Shell
Help Text
Select this option to boot now.
Note: This list is not the system boot option order. Use the
Boot Options menu to view and configure the system boot
option order.
Boot Device #x
Select this option to boot now.
Note: This list is not the system boot option order. Use the
Boot Options menu to view and configure the system boot
option order.
Loading BIOS Defaults
Different mechanisms exist for resetting the system configuration to the default values. When a
request to reset the system configuration is detected, the BIOS loads the default system
configuration values during the next POST. You can send the request to reset the system to the
defaults in the following ways:
74

Pressing <F9> from within the BIOS Setup utility.

Moving the clear system configuration jumper.
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS
BIOS User Interface

IPMI command (set System Boot options command)

Int15 AX=DA209

Choosing Load User Defaults from the Exit page of the BIOS Setup loads user set
defaults instead of the BIOS factory defaults.
The recommended steps to load the BIOS defaults are:
1. Power down the system (Do not remove AC power).
2. Move the Clear CMOS jumper from pins 1-2 to pins 2-3.
3. Move the Clear CMOS jumper from pins 2-3 to pins 1-2.
4. Power up the system.
Revision 2.4
Intel order number E65697-010
75
Connector/Header Locations and Pin-outs
7.
7.1
Intel® Server Board S3420GP TPS
Connector/Header Locations and Pin-outs
Board Connector Information
The following section provides detailed information regarding all connectors, headers, and
jumpers on the server board. It lists all connector types available on the board and the
corresponding reference designators printed on the silkscreen.
Table 38. Board Connector Matrix
Connector
Power supply
Quantity
3
J9A1, J9C1
Connector Type
Main power
CPU power
Pin Count
24
8
CPU
1
J6G1
CPU sockets
1156
Main memory
Reference Designators
6
J8J3, J8J2, J8J1, J9J3, J9J2, J8J4
DIMM sockets
240
Intel RMM3
1
J2C1
Header
34
50-pin PCI
Express*
Connector
1
J2H1
Header
50
®
CPU Fan
1
J6D1
Header
4
System Fans
4
J1J4, J6J2, J7J1, J6B1
Header
4
Battery
NIC/Stack 2x USB
1
2
BT5C1
J5A1, J6A1
Battery holder
Dual USB
3
8
Video
1
J7A1
External DSub
15
Serial port A
1
J8A1
Connector
9
Serial port B
1
J1B2
Header
9
Front panel
USB floppy
1
1
J4H3
J1C1
Header
Header
24
4
Dual- USB Internal
Header
PCI-E x16
2
J1D1, J1E1
Header
10
1
J4B3
Card Edge
164
PCI-E x8
3
J2B2, J3B1, J4B2
Card Edge
98
PCI-E x4
1
J2B1
Card Edge
64
PCI 32
1
J1B1
Card Edge
120
XDP Connector
Chassis Intrusion
1
1
J5J1
J4B1
Connector
Header
60
2
Serial ATA
6
J1H4, J1H1, J1G1, J1H3, J1G3, J1F4
Header
7
IPMB
1
J1H2
Header
4
HSBP
1
J1J1
Header
4
Z-U130 USB
SATA_SGPIO
1
1
J3F2
J1J3
Header
Header
10
4
7.2
Power Connectors
The main power supply connection uses an SSI-compliant 2x12 pin connector (J9A1). In
addition, there is one additional power related connector:

76
One SSI-compliant 2x4 pin power connector (J9C1), which provides 12-V power to the
CPU VRD.
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS
Connector/Header Locations and Pin-outs
The following tables define the connector pin-outs.
Table 39. Baseboard Power Connector Pin-out (J9A1)
Signal
Color
1
Pin
+3.3 Vdc
Orange
13
Pin
+3.3 Vdc
Signal
Orange
Color
2
+3.3 Vdc
Orange
14
-12 Vdc
Blue
3
GND
Black
15
GND
Black
4
+5 Vdc
Red
16
PS_ON#
Green
5
GND
Black
17
GND
Black
6
+5 Vdc
Red
18
GND
Black
7
GND
Black
19
GND
Black
8
PWRGD_PS Gray
20
NC
White
9
5 VSB
Purple
21
+5 Vdc
Red
10
+12 Vdc
Yellow
22
+5 Vdc
Red
11
+12 Vdc
Yellow
23
+5 Vdc
Red
12
+3.3 Vdc
Orange
24
GND
Black
Table 40. SSI Processor Power Connector Pin-out (J9C1)
7.3
Pin
1
Signal
GND
Color
Black
2
3
GND
GND
Black
Black
4
GND
Black
5
+12 Vdc
Yellow/black
6
7
8
+12 Vdc
+12 Vdc
+12 Vdc
Yellow/black
Yellow/black
Yellow/black
System Management Headers
7.3.1
Intel® Remote Management Module 3 (Intel® RMM3) Connector
®
A 34-pin Intel RMM 3 connector (J2C1) is included on the server board to support the optional
Intel® Remote Management Module 3. This server board does not support third-party
management cards.
Note: This connector is not compatible with the Intel® Remote Management Module (Intel®
RMM) or the Intel® Remote Management Module 2 (Intel® RMM2).
Revision 2.4
Intel order number E65697-010
77
Connector/Header Locations and Pin-outs
Intel® Server Board S3420GP TPS
Table 41. Intel® RMM3 Connector Pin-out (J2C1)
Pin
7.3.2
1
Signal Name
P3V3_AUX
2
Pin
Signal Name
RMII_IBMC_RMM3_MDIO
3
P3V3_AUX
4
RMII_IBMC_RMM3_MDC
5
7
GND
GND
6
8
RMII_IBMC_RMM3_RXD1
RMII_IBMC_RMM3_RXD0
9
GND
10
RMII_IBMC_RMM3_CRS_DV
11
GND
12
CLK_50M_RMM3
13
GND
14
RMII_IBMC_RMM3_RX_ER
15
GND
16
RMII_IBMC_RMM3_TX_EN
17
19
GND
GND
18
20
KEY
RMII_IBMC_RMM3_TXD0
21
GND
22
RMII_IBMC_RMM3_TXD1
23
P3V3_AUX
24
SPI_IBMC_BK_CS_N
25
P3V3_AUX
26
TP_RMM3_SPI_WE
27
29
P3V3_AUX
GND
28
30
SPI_IBMC_BK_DO
SPI_IBMC_BK_CLK
31
GND
32
SPI_IBMC_BK_DI
33
GND
34
FM_RMM3_Present_N
LCP/IPMB Header
Table 42. LPC/IPMB Header Pin-out (J1H2)
Pin
1
7.3.3
Signal Name
SMB_IPMB_5VSB_DAT
Description
Integrated BMC IMB 5V standby
data line
2
GND
Ground
3
SMB_IPMB_5VSB_CLK
Integrated BMC IMB 5V standby
clock line
4
P5V_STBY
+5 V standby power
HSBP Header
Table 43. HSBP Header Pin-out (J1J1)
Pin
1
2
3
4
78
Signal Name
SMB_HSBP_5V_DAT
GND
SMB_HSBP_5V_CLK
FM_HSBP_ADD_C2
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS
7.3.4
Connector/Header Locations and Pin-outs
SGPIO Header
Table 44. SGPIO Header Pin-out (J1J3)
Pin
1
2
3
4
7.4
Signal Name
SGPIO_CLOCK
SGPIO_LOAD
SGPIO_DATAOUT0
SGPIO_DATAOUT1
Description
SGPIO Clock Signal
SGPIO Load Signal
SGPIO Data Out
SGPIO Data In
Front Control Panel Connector
The server board provides a 24-pin SSI front panel connector (J1C1) for use with Intel® and
third-party chassis. The following table provides the pin-out for this connector.
Table 45. Front Panel SSI Standard 24-pin Connector Pin-out (J1C1)
1
Pin
Signal Name
P3V3_AUX
(Power_LED_Anode)
Description
Power LED +
2
Pin
Signal Name
P3V3_STBY
Description
Front Panel
Power
3
Key
No Connection
4
P5V_STBY (ID LED
Anode)
ID LED +
5
FP_PWR_LED_N
Power LED -
6
FP_ID_LED_BUF_N
ID LED -
7
P3V3
(HDD_ACTIVITY_Anode)
HDD Activity
LED+
8
FP_LED_STATUS_GR
EEN_N
Status LED
Green -
9
LED_HDD_ACTIVITY_N
HDD Activity
LED-
10
FP_LED_STATUS_AM
BER_N
Status LED
Amber
11
FP_PWR_BTN_N
Power Button
12
NIC1_ACT_LED_N
NIC 1 Activity
LED -
13
GND (Power Button
GND)
Power Button
Ground
14
NIC1_LINK_LED_N
NIC 1 Link LED -
15
RST_FP_BTN_N
Reset Button
16
17
GND (Reset GND)
18
19
FP_ID_BTN_N
Reset Button
Ground
ID Button
20
SMB_SENSOR_3V3ST
B_DATA
SMB_SENSOR_3V3ST
B_CLK
FP_CHASS_INTRU
SMB Sensor
DATA
SMB Sensor
Clock
Chassis Intrusion
21
PU_FM_SIO_TEMP_SE
NSOR
Front Panel
Temperature
Sensor
22
NIC2_ACT_LED_N
NIC 2 Activity
LED -
23
FP_NMI_BTN_N
NMI Button
24
NIC2_LINK_LED_N
NIC 2 Link LED -
Combined system BIOS and the Integrated BMC support provide the functionality of the various
supported control panel buttons and LEDs. The following sections describe the supported
functionality of each control panel feature.
Note: Control panel features are also routed through the bridge board connector at location
J1C1 as is implemented in Intel® Server Systems configured using a bridge board and a hotswap backplane.
Revision 2.4
Intel order number E65697-010
79
Connector/Header Locations and Pin-outs
7.4.1
Intel® Server Board S3420GP TPS
Power Button
The BIOS supports a front control panel power button. Pressing the power button initiates a
request that the Integrated BMC forwards to the ACPI power state machines in the chipset. It is
monitored by the Integrated BMC and does not directly control power on the power supply.

Power Button — Off to On
The Integrated BMC monitors the power button and the wake-up event signals from the
chipset. A transition from either source results in the Integrated BMC starting the powerup sequence. Since the processor are not executing, the BIOS does not participate in
this sequence. The hardware receives the power good and reset signals from the
Integrated BMC and then transitions to an ON state.

Power Button — On to Off (Operating system absent)
The System Control Interrupt (SCI) is masked. The BIOS sets up the power button event
to generate an SMI and checks the power button status bit in the ACPI hardware
registers when an SMI occurs. If the status bit is set, the BIOS sets the ACPI power
state of the machine in the chipset to the OFF state. The Integrated BMC monitors
power state signals from the chipset and de-asserts PS_PWR_ON to the power supply.
As a safety mechanism, if the BIOS fails to service the request, the Integrated BMC
automatically powers off the system in 4 to 5 seconds.

Power Button — On to Off (Operating system present)
If an ACPI operating system is running, pressing the power button switch generates a
request using SCI to the operating system to shut down the system. The operating
system retains control of the system and the operating system policy determines the
sleep state into which the system transitions, if any. Otherwise, the BIOS turns off the
system.
7.4.2
Reset Button
The platform supports a front control panel reset button. Pressing the reset button initiates a
request forwarded by the Integrated BMC to the chipset. The BIOS does not affect the behavior
of the reset button.
7.4.3
NMI Button
®
The Intel S3420GP Server Board family BIOS does not support the NMI button.
7.4.4
System Status Indicator LED
®
The Intel Server Board S3420GP that uses the Intel® Xeon® Processor 3400 Series has a
system status indicator LED on the front panel. This indicator LED has specific states and
corresponding interpretation as shown in the following table.
Table 46. System Status LED Indicator States
Color
Green
80
State
Solid on
Criticality
Ok
Description
System booted and ready
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS
Color
Green
Amber
State
~1 Hz blink
~1 Hz blink
Amber
Solid on
Off
Connector/Header Locations and Pin-outs
Criticality
Degraded
Description
System degraded:

Non-critical temperature threshold asserted.
Non-critical
Non-critical voltage threshold asserted.

Non-critical fan threshold asserted.

Fan redundancy lost, sufficient system cooling maintained.
This does not apply to non-redundant systems.

Power supply predictive failure.

Power supply redundancy lost. This does not apply to nonredundant systems.

Correctable errors over a threshold of 10 and migrating to a
spare DIMM (memory sparing). This indicates the user no
longer has spared DIMMs indicating a redundancy lost
1
condition. Corresponding DIMM LED should light up.
Non-fatal alarm – system is likely to fail:

CATERR asserted.
Critical, nonrecoverable
N/A


Critical temperature threshold asserted.

Critical voltage threshold asserted.

Critical fan threshold asserted.

VRD hot asserted.

SMI Timeout asserted.
Fatal alarm – system has failed or shutdown:

Thermtrip asserted.
Not ready

Non-recoverable temperature threshold asserted.

Non-recoverable voltage threshold asserted.

Power fault/Power Control Failure.

Fan redundancy lost, insufficient system cooling. This does
not apply to non-redundant systems.
AC power off, if no degraded, non-critical, critical, or non-recoverable
conditions exist.
Notes:
1. The BIOS detects these conditions and sends a Set Fault Indication command to the Integrated BMC to provide
the contribution to the system status LED.
2. Support for upper non-critical limit is not provided in the default SDR configuration. However, if a user does
enable this threshold in the SDR, then the system status LED should behave as described.
There is no precedence or lock-out mechanism for the control sources. When a new request
arrives, all previous requests are terminated. For example, if the chassis ID LED is blinking and
the chassis ID button is pressed, then the chassis ID LED changes to solid on. If the button is
pressed again with no intervening commands, the chassis ID LED turns off.
7.5
I/O Connectors
7.5.1
VGA Connector
The following table details the pin-out definition of the VGA connector (J7A1).
Table 47. VGA Connector Pin-out (J7A1)
Pin
Revision 2.4
1
Signal Name
V_IO_R_CONN
Description
Red (analog color signal R)
2
V_IO_G_CONN
Green (analog color signal G)
Intel order number E65697-010
81
Connector/Header Locations and Pin-outs
Pin
7.5.2
Intel® Server Board S3420GP TPS
3
Signal Name
V_IO_B_CONN
Description
Blue (analog color signal B)
4
5
TP_VID_CONN_B4
GND
No connection
Ground
6
GND
Ground
7
GND
Ground
8
GND
Ground
9
10
TP_VID_CONN_B9
GND
No connection
Ground
11
TP_VID_CONN_B11
No connection
12
V_IO_DDCDAT
DDCDAT
13
V_IO_HSYNC_CONN
HSYNC (horizontal sync)
14
V_IO_VSYNC_CONN
VSYNC (vertical sync)
15
V_IO_DDCCLK
DDCCLK
Rear NIC and USB connector
The server board provides two stacked RJ-45/2xUSB connectors side-by-side on the back edge
of the board (J6A1, J5A1). The pin-out for NIC connectors are identical and defined in the
following table.
Table 48. RJ-45 10/100/1000 NIC Connector Pin-out (J5A1)
Pin
1
3
5
7
9
11
13
15
17
19
21
Signal Name
P5V_USB_PWR75
USB_PCH_11_FB_DP
P5V_USB_PWR75
USB_PCH_10_FB_DP
P1V9_LAN2_R
NIC2_MDIN<0>
NIC2_MDIN<1>
NIC2_MDIN<2>
NIC2_MDIN<3>
LED_NIC2_1
LED_NIC2_LINK100_R_0
Pin
2
4
6
8
10
12
14
16
18
20
22
Signal Name
USB_PCH_11_FB_DN
GND
USB_PCH_10_FB_DN
GND
NIC2_MDIP<0>
NIC2_MDIP<1>
NIC2_MDIP<2>
NIC2_MDIP<3>
GND
P3V3_AUX
LED_NIC2_LINK1000_2
Table 49. RJ-45 10/100/1000 NIC Connector Pin-out (J6A1)
Pin
1
3
5
7
9
11
13
15
17
19
82
Signal Name
P5V_USB_PWR75
USB_PCH_11_FB_DP
P5V_USB_PWR75
USB_PCH_10_FB_DP
P1V8_PHY_VCT_R
NIC1_MDIN<0>
NIC1_MDIN<1>
NIC1_MDIN<2>
NIC1_MDIN<3>
LED_NIC1_LINK_ACT_0_R
Pin
2
4
6
8
10
12
14
16
18
20
Signal Name
USB_PCH_11_FB_DN
GND
USB_PCH_10_FB_DN
GND
NIC1_MDIP<0>
NIC1_MDIP<1>
NIC2_MDIP<2>
NIC2_MDIP<3>
GND
P3V3_AUX
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS
Pin
Signal Name
LED_NIC1_2
21
7.5.3
Connector/Header Locations and Pin-outs
Pin
22
Signal Name
LED_NIC1_LINK1000_1
SATA
The sever board provides up to six SATA connectors. The pin configuration for each connector
is identical and defined in the following table.
Table 50. SATA Connector Pin-out (J1H4, J1H1, J1G1, J1H3, J1G3, J1F4)
Pin
7.5.4
Signal Name
Description
1
GND
Ground
2
3
SATA/SAS_TX_P_C
SATA/SAS_TX_N_C
Positive side of transmit differential pair
Negative side of transmit differential pair
4
GND
Ground
5
SATA/SAS_RX_N_C
Negative side of receive differential pair
6
SATA/SAS_RX_P_C
Positive side of receive differential pair
7
GND
Ground
50-pin PCI Express* Connector
®
The Intel Server Board S3420GPLX provides one 50-pin PCI Express* connector for Intel®
SAS Entry RAID Module AXX4SASMOD.
The pin configuration is identical and defined in the following table.
Table 51. 50-pin PCI Express* Connector Pin-out (J2H1)
Revision 2.4
Pin
1
Signal Name
P3V3_AUX
Pin
3
PE_RST_IO_MODULE_N 4
GND
5
7
GND
GND
PE2_ESB_RXP_C<0>
PE2_ESB_RXN_C<0>
2
6
8
Signal Name
P3V3_AUX
9
PE2_ESB_TXP_C<0>
10
GND
11
PE2_ESB_TXN_C<0>
12
GND
13
GND
14
PE2_ESB_RXP_C<1>
15
17
GND
PE2_ESB_TXP_C<1>
16
18
PE2_ESB_RXN_C<1>
GND
19
PE2_ESB_TXN_C<1>
20
GND
21
GND
22
PE2_ESB_RXP_C<2>
23
GND
24
PE2_ESB_RXN_C<2>
25
27
PE2_ESB_TXP_C<2>
PE2_ESB_TXN_C<2>
26
28
GND
GND
29
GND
30
PE2_ESB_RXP_C<3>
31
GND
32
PE2_ESB_RXN_C<3>
33
PE2_ESB_TXP_C<3>
34
GND
35
PE2_ESB_TXN_C<3>
36
GND
37
39
GND
GND
38
40
CLK_100M_LP_PCIE_SLOT3_P
CLK_100M_LP_PCIE_SLOT3_N
41
PE_WAKE_N
42
GND
43
P3V3
44
P3V3
Intel order number E65697-010
83
Connector/Header Locations and Pin-outs
7.5.5
Intel® Server Board S3420GP TPS
Pin
45
P3V3
Signal Name
46
Pin
P3V3
Signal Name
47
49
P3V3
P3V3
48
50
P3V3
P3V3
Serial Port Connectors
The server board provides one external DB9 Serial A port (J8A1) and one internal 9-pin serial B
header (J1B2). The following tables define the pin-outs.
Table 52. External Serial A Port Pin-out (J8A1)
1
Pin
Signal Name
SPA_DCD
Description
DCD (carrier detect)
2
SPA_SIN_L
RXD (receive data)
3
4
SPA_SOUT_N
SPA_DTR
TXD (Transmit data)
DTR (Data terminal ready)
5
GND
Ground
6
SPA_DSR
DSR (data set ready)
7
SPA_RTS
RTS (request to send)
8
SPA_CTS
CTS (clear to send)
9
10
SPA_RI
NC
RI (Ring Indicate)
Table 53. Internal 9-pin Serial B Header Pin-out (J1B2)
7.5.6
Pin
1
Signal Name
SPB_DCD
Description
DCD (carrier detect)
2
SPB_DSR
DSR (data set ready)
3
4
SPB_SIN_L
SPB_RTS
RXD (receive data)
RTS (request to send)
5
SPB_SOUT_N
TXD (Transmit data)
6
SPB_CTS
CTS (clear to send)
7
SPB_DTR
DTR (Data terminal ready)
8
9
SPB_RI
SPB_EN_N
RI (Ring indicate)
Enable
10
NC
USB Connector
There are four external USB ports on two NIC/USB combinations. Section 5.5.2 details the pinout of the connector.
Two 2x5 connector on the server board (J1E1, J1D1) provides an option to support an
additional USB port, each connector supporting two USB ports. The following table defines the
pin-out of the connector.
Table 54. Internal USB Connector Pin-out ( J1E1, J1D1)
84
Pin
1
Signal Name
USB2_VBUS4
Description
USB power (port 4)
2
USB2_VBUS5
USB power (port 5)
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS
Connector/Header Locations and Pin-outs
Pin
3
Signal Name
USB_ICH_P4N_CONN
Description
USB port 4 negative signal
4
5
USB_ICH_P5N_CONN
USB_ICH_P4P_CONN
USB port 5 negative signal
USB port 4 positive signal
6
USB_ICH_P5P_CONN
USB port 5 positive signal
7
Ground
8
Ground
9
10
Key
TP_USB_ICH_NC
No pin
Test point
One x connector (J1J2) on the server board provides an option to support a USB floppy
connector.
Table 55. Pin-out of Internal USB Connector for Floppy ( J1J2)
Pin
1
2
3
4
Signal Name
+5V
USB_N
USB_P
GND
One 2x5 connectors (J3F2) on the server board provides an option to support an Intel® Z-U130
Value Solid State Drive. The following table defines the pin-out of the connector.
Table 56. Pin-out of Internal USB Connector for low-profile Intel® Z-U130 Value Solid State Drive
(J3F2)
7.6
Pin
1
+5V
Signal Name
Description
USB power
2
NC
N/A
3
4
USB Data NC
USB port ## negative signal
N/A
5
USB Data +
USB port ## positive signal
6
NC
N/A
7
Ground
N/A
8
9
NC
Key
N/A
No pin
10
LED#
Activity LED
PCI Express* Slot/PCI Slot/Riser Card Slot
A PCI-E Riser card will enable a PCI-E add-on card to be accommodated in the 1U chassis.
The following table shows the pin-out for this riser slot.
Table 57. Pin-out of adaptive riser slot/PCI Express slot 6
Pin
B1
B2
B3
Revision 2.4
Signal
+12V
+12V
RSVD
Description
P12V
P12V
P12V
Pin
A1
A2
A3
Signal
PRSNT1_N
+12V
+12V
Intel order number E65697-010
Description
GND
P12V
P12V
85
Connector/Header Locations and Pin-outs
Pin
B4
B5
B6
B7
B8
B9
B10
B11
Signal
GND
SMCLK
SMDATA
GND
+3.3V
JTAG1
+3.3VAUX
WAKE_N
B12
RSVD
B13
GND
B14
PETP0
B15
PETN0
B16
GND
B17
PRSNT2_N
B18
GND
B19
PETP1
B20
PETN1
B21
GND
B22
GND
B23
PETP2
B24
PETN2
B25
GND
B26
GND
B27
PETP3
B28
PETN3
B29
GND
B30
RSVD
B31
PRSNT2_N
B32
GND
End of x4
B33
PETP4
B34
PETN4
B35
GND
B36
GND
B37
PETP5
B38
PETN5
B39
GND
B40
GND
B41
PETP6
B42
PETN6
B43
GND
B44
GND
B45
PETP7
B46
PETN7
B47
GND
86
Intel® Server Board S3420GP TPS
Description
GND
PU_S6_SMBCLK
PU_S6_SMBDAT
GND
P3V3
JTAG_S6_TRST_N
P3V3_AUX
FM_PE_WAKE_N
KEY
KEY
NC
GND
P2E_CPU_C_S6_TXP<7>
P2E_CPU_C_S6_TXN<7>
GND
NC
GND
P2E_CPU_C_S6_TXP<6>
P2E_CPU_C_S6_TXN<6>
GND
GND
P2E_CPU_C_S6_TXP<5>
P2E_CPU_C_S6_TXN<5>
GND
GND
P2E_CPU_C_S6_TXP<4>
P2E_CPU_C_S6_TXN<4>
GND
NC
NC
GND
P2E_CPU_C_S6_TXP<3>
P2E_CPU_C_S6_TXN<3>
GND
GND
P2E_CPU_C_S6_TXP<2>
P2E_CPU_C_S6_TXN<2>
GND
GND
P2E_CPU_C_S6_TXP<1>
P2E_CPU_C_S6_TXN<1>
GND
GND
P2E_CPU_C_S6_TXP<0>
P2E_CPU_C_S6_TXN<0>
GND
Pin
A4
A5
A6
A7
A8
A9
A10
A11
Signal
GND
JTAG2
JTAG3
JTAG4
JTAG5
+3_3V
+3_3V
PERST_N
A12
GND
A13
REFCLKP
A14
REFCLKN
A15
GND
A16
PERP0
A17
PERN0
A18
GND
A19
RSVD
A20
GND
A21
PERP1
A22
PERN1
A23
GND
A24
GND
A25
PERP2
A26
PERN2
A27
GND
A28
GND
A29
PERP3
A30
PERN3
A31
GND
A32
RSVD
End of x4
A33
RSVD
A34
GND
A35
PERP4
A36
PERN4
A37
GND
A38
GND
A39
PERP5
A40
PERN5
A41
GND
A42
GND
A43
PERP6
A44
PERN6
A45
GND
A46
GND
A47
PERP7
Intel order number E65697-010
Description
GND
P3V3_RISER_A5
JTAG_S6_TDI
NC
P3V3_RISER_A8
P3V3
P3V3
RST_PE_S236_N_R1
KEY
KEY
GND
CLK_100M_SLOT6A_DP
CLK_100M_SLOT6A_DPN
GND
P2E_CPU_S6_RXP<7>
P2E_CPU_S6_RXN<7>
GND
NC
GND
P2E_CPU_S6_RXP<6>
P2E_CPU_S6_RXN<6>
GND
GND
P2E_CPU_S6_RXP<5>
P2E_CPU_S6_RXN<5>
GND
GND
P2E_CPU_S6_RXP<4>
P2E_CPU_S6_RXN<4>
GND
NC
NC
GND
P2E_CPU_S6_RXN<3>
P2E_CPU_S6_RXP<3>
GND
GND
P2E_CPU_S6_RXN<2>
P2E_CPU_S6_RXP<2>
GND
GND
P2E_CPU_S6_RXN<1>
P2E_CPU_S6_RXP<1>
GND
GND
P2E_CPU_S6_RXN<0>
Revision 2.4
Intel® Server Board S3420GP TPS
Pin
Signal
B48
PRSNT2_N
B49
GND
End of x8
B50
PETP8
B51
PETN8
B52
GND
B53
GND
B54
PETP9
B55
PETN9
B56
GND
B57
GND
B58
PETP10
B59
PETN10
B60
GND
B61
GND
B62
PExP11
B63
PETN11
B64
GND
B65
GND
B66
PETP12
B67
PETN12
B68
GND
B69
GND
B70
PETP13
B71
PETN13
B72
GND
B73
GND
B74
PETP14
B75
PETN14
B76
GND
B77
GND
B78
PETP15
B79
PETN15
B80
GND
B81
PRSNT2_N
B82
RSVD
Connector/Header Locations and Pin-outs
Description
NC
GND
NC
NC
GND
GND
NC
NC
GND
GND
NC
NC
GND
GND
NC
NC
GND
GND
NC
NC
GND
GND
NC
NC
GND
GND
NC
NC
GND
GND
NC
NC
GND
NC
NC
Pin
Signal
A48
PERN7
A49
GND
End of x8
A50
RSVD
A51
GND
A52
PERP8
A53
PERN8
A54
GND
A55
GND
A56
PERP9
A57
PERN9
A58
GND
A59
GND
A60
PERP10
A61
PERN10
A62
GND
A63
GND
A64
PERP11
A65
PERN11
A66
GND
A67
GND
A68
PERP12
A69
PERN12
A70
GND
A71
GND
A72
PERP13
A73
PERN13
A74
GND
A75
GND
A76
PERP14
A77
PERN14
A78
GND
A79
GND
A80
PERP15
A81
PERN15
A82
GND
Description
P2E_CPU_S6_RXP<0>
GND
NC
GND
NC
NC
GND
GND
NC
NC
GND
GND
NC
NC
GND
GND
NC
NC
GND
GND
NC
NC
GND
GND
NC
NC
GND
GND
NC
NC
GND
GND
NC
NC
GND
Three PCI Express* x8 connectors (J2B2, J3B1 and J4B2)
Pin
Signal
Pin
Signal
Pin
Signal
Pin
Signal
A1
PRSNT1#
B1
+12V
A26
HSIP[2]
B26
GND
A2
+12V
B2
+12V
A27
GND
B27
HSOP[3]
A3
+12V
B3
RESERVED
A28
GND
B28
HSON[3]
A4
GND
B4
GND
A29
HSIP[3]
B29
GND
Revision 2.4
Intel order number E65697-010
87
Connector/Header Locations and Pin-outs
Pin
Signal
Intel® Server Board S3420GP TPS
Pin
Signal
Pin
Signal
Pin
Signal
A5
JTAG2/TCk
B5
SMCLK
A30
HSIN[3]
B30
RESERVED
A6
JTAG3/TDI
B6
SMDAT
A31
GND
B31
PRSNT2#
A7
JTAG4/TDO
B7
GND
A32
RESERVED
B32
GND
A8
JTAG5/TMS
B8
+3.3V
A33
RESERVED
B33
HSOP[4]
A9
+3.3V
B9
JTAG1/TRST#
A34
GND
B34
HSON[4]
A10
+3.3V
B10
3.3VAUX
A35
HSIP[4]
B35
GND
A11
PERST#
B11
WAKE#
A36
HSIN[4]
B36
GND
A12
GND
B12
RESERVED
A37
GND
B37
HSOP[5]
A13
REFCLK+
B13
GND
A38
GND
B38
HSON[5]
A14
REFCLK-
B14
HSOP[0]
A39
HSIP[5]
B39
GND
A15
GND
B15
HSON[0]
A40
HSIN[5]
B40
GND
A16
HSIP[0]
B16
GND
A41
GND
B41
HSOP[6]
A17
HSIN[0]
B17
PRSNT2#
A42
GND
B42
HSON[6]
A18
GND
B18
GND
A43
HSIP[6]
B43
GND
A19
RESERVED
B19
HSOP[1]
A44
HSIN[6]
B44
GND
A20
GND
B20
HSON[1]
A45
GND
B45
HSOP[7]
A21
HSIP[1]
B21
GND
A46
GND
B46
HSON[7]
A22
HSIN[1]
B22
GND
A47
HSIP[7]
B47
GND
A23
GND
B23
HSOP[2]
A48
HSIN[7]
B48
PRSNT2#
A24
GND
B24
HSON[2]
A49
GND
B49
GND
A25
HSIP[2]
B25
GND
One PCI Express* X4 connector (J2B1)
Pin#
Signal
Pin#
Signal
Pin#
Signal
Pin#
Signal
A1
PRSNT1_N
B1
+12V
A17
PERN0
B17
PRSNT2_N
A2
+12V
B2
+12V
A18
GND
B18
GND
A3
+12V
B3
RSVD
A19
RSVD
B19
PETP1
A4
GND
B4
GND
A20
GND
B20
PETN1
A5
JTAG2
B5
SMCLK
A21
PERP1
B21
GND
A6
JTAG3
B6
SMDAT
A22
PERN1
B22
GND
A7
JTAG4
B7
GND
A23
GND
B23
PETP2
A8
JTAG5
B8
+3.3V
A24
GND
B24
PETN2
88
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS
Pin#
Signal
Connector/Header Locations and Pin-outs
Pin#
Signal
Pin#
Signal
Pin#
Signal
A9
+3.3V
B9
JTAG1
A25
PERP2
B25
GND
A10
+3.3V
B10
3.3VAUX
A26
PERN2
B26
GND
A11
PERST_N
B11
WAKE_N
A27
GND
B27
PETP3
A12
GND
B12
RSVD
A28
GND
B28
PETN3
A13
REFCLK+
B13
GND
A29
PERP3
B29
GND
A14
REFCLK-
B14
PETP0
A30
PERN3
B30
RSVD
A15
GND
B15
PETN0
A31
GND
B31
PRSNT2_N
A16
PERP0
B16
GND
A32
RSVD
B32
GND
One PCI X32 connector (J1B1)
Pin #
Signal
Pin #
Signal
Pin #
Signal
Pin #
Signal
B1
-12V
A1
TRST#
B32
AD[17]
A32
AD[16]
B2
B3
B4
B5
B6
B7
B8
B9
B10
B11
B12
B13
B14
B15
B16
B17
B18
B19
B20
B21
B22
B23
B24
TCK
Ground
TDO
+5V
+5V
INTB#
INTD#
PRSNT1#
RSVD
PRSNT2#
GND
GND
RSVD
Ground
CLK
Ground
REQ#
V_IO
AD[31]
AD[29]
Ground
AD[27]
AD[25]
A2
A3
A4
A5
A6
A7
A8
A9
A10
A11
A12
A13
A14
A15
A16
A17
A18
A19
A20
A21
A22
A23
A24
+12V
TMS
TDI
+5V
INTA#
INTC#
+5V
RSVD
V_IO
RSVD
GND
GND
3.3Vaux
RST#
V_IO
GNT#
Ground
PME#
AD[30]
+3.3V
AD[28]
AD[26]
Ground
B33
B34
B35
B36
B37
B38
B39
B40
B41
B42
B43
B44
B45
B46
B47
B48
B49
B50
B51
B52
B53
B54
B55
C/BE[2]#
Ground
IRDY#
+3.3V
DEVSEL#
Ground
LOCK#
PERR#
+3.3V
SERR#
+3.3V
C/BE[1]#
AD[14]
Ground
AD[12]
AD[10]
M66EN
KEY
KEY
AD[08]
AD[07]
+3.3V
AD[05]
A33
A34
A35
A36
A37
A38
A39
A40
A41
A42
A43
A44
A45
A46
A47
A48
A49
A50
A51
A52
A53
A54
A55
+3.3V
FRAME#
Ground
TRDY#
Ground
STOP#
+3.3V
RSVD
RSVD
Ground
PAR
AD[15]
+3.3V
AD[13]
AD[11]
Ground
AD[09]
KEY
KEY
C/BE[0]#
+3.3V
AD[06]
AD[04]
B25
B26
B27
B28
B29
B30
B31
+3.3V
C/BE[3]#
AD[23]
Ground
AD[21]
AD[19]
+3.3V
A25
A26
A27
A28
A29
A30
A31
AD[24]
IDSEL
+3.3V
AD[22]
AD[20]
Ground
AD[18]
B56
B57
B58
B59
B60
B61
B62
AD[03]
Ground
AD[01]
V_IO
ACK64#
+5V
+5V
A56
A57
A58
A59
A60
A61
A62
Ground
AD[02]
AD[00]
V_IO
REQ64#
+5V
+5V
Revision 2.4
Intel order number E65697-010
89
Connector/Header Locations and Pin-outs
7.7
Intel® Server Board S3420GP TPS
Fan Headers
The server board provides five SSI-compliant 4-pin fan headers to be used as the CPU and
chassis. The pin configuration for each of the 4-pin fan headers is identical and defined in the
following table.

One 4-pin fan headers are designated as processor cooling fans:
-
CPU fan (J6D1)
SYS1 fan (J1J4)
SYS2 fan (J6J2)
SYS3 fan (J7J1)
SYS4 fan (J6B1)
Table 58. SSI 4-pin Fan Header Pin-out (J6D1, J1J4, J6J2, J7J1, J6B1)
1
Pin
Signal Name
Ground
Type
GND
Description
Ground is the power supply ground
2
12 V
Power
Power supply 12 V
3
Fan Tach
In
FAN_TACH signal is connected to the Integrated BMC to monitor the fan
speed
4
Fan PWM
Out
FAN_PWM signal to control fan speed
90
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS
8.
Jumper Blocks
Jumper Blocks
The server board has several 3-pin jumper blocks that can be used to configure, protect, or
recover specific features of the server board.
Figure 39. Jumper Blocks (J1A2, J1F1, J1F3, J1F2 and J1F5)
Table 59. Server Board Jumpers (J1F1, J1F2, J1F3, J1F5, J1A2)
Jumper Name
J1F5: CMOS
Clear
Pins
1-2
2-3
J1F1: ME Force
Update
J1F2:
Password Clear
1-2
2-3
1-2
2-3
J1F3: BIOS
Recovery
1-2
2-3
J1A2: BMC
Force Update
1-2
2-3
Revision 2.4
System Results
These pins should have a jumper in place for normal system operation. (Default)
If these pins are jumpered with AC power plugged, the CMOS settings are cleared within
five seconds. These pins should not be jumpered for normal operation.
ME Firmware Force Update Mode – Disabled (Default)
ME Firmware Force Update Mode – Enabled
These pins should have a jumper in place for normal system operation. (Default)
If these pins are jumpered, administrator and user passwords are cleared within 5-10
seconds after the system is powered on. These pins should not be jumpered for normal
operation.
These pins should have a jumper in place for normal system operation. (Default)
Given that the main system BIOS will not boot with these pins jumpered, system can only
boot from EFI-bootable recovery media with the recovery BIOS image.
Integrated BMC Firmware Force Update Mode – Disabled (Default)
Integrated BMC Firmware Force Update Mode – Enabled
Intel order number E65697-010
91
Jumper Blocks
8.1
Intel® Server Board S3420GP TPS
CMOS Clear and Password Reset Usage Procedure
The CMOS Clear (J1F5) and Password Reset (J1F2) recovery features are designed such that
the desired operation can be achieved with minimal system downtime. The usage procedure for
these two features has changed from previous generation Intel server boards. The following
procedure outlines the new usage model.
8.1.1
Clearing the CMOS
To clear the CMOS, perform the following steps:
1. Power down the server. Do not unplug the power cord.
2. Open the server chassis. For instructions, see your server chassis documentation.
3. Move jumper (J1F5) from the default operating position (covering pins 1 and 2) to the
reset/clear position (covering pins 2 and 3).
4. Wait five seconds.
5. Remove AC power.
6. Move the jumper back to the default position (covering pins 1 and 2).
7. Close the server chassis.
8. Power up the server.
The CMOS is now cleared and can be reset by going into the BIOS setup.
Note: Removing AC power before performing the CMOS clear operation causes the system to
automatically power up and immediately power down, after the procedure is followed and AC
power is re-applied. If this happens, remove the AC power cord again, wait 30 seconds, and reinstall the AC power cord. Power up the system and proceed to the <F2> BIOS Setup utility to
reset the preferred settings.
8.1.2
Clearing the Password
To clear the password, perform the following steps:
1. Power down the server. Do not unplug the power cord.
2. Open the chassis. For instructions, see your server chassis documentation.
3. Move jumper (J1F2) from the default operating position (covering pins 1 and 2) to the
password clear position (covering pins 2 and 3).
4. Close the server chassis.
5. Power up the server and wait 10 seconds or until POST completes.
6. Power down the server.
7. Open the chassis and move the jumper back to the default position (covering pins 1 and
2).
8. Close the server chassis.
9. Power up the server.
The password is now cleared and can be reset by going into the BIOS setup.
92
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS
8.2
Jumper Blocks
Integrated BMC Force Update Procedure (only for the Intel® Server Board
S3420GPLX and S3420GPLC)
When performing the standard Integrated BMC firmware update procedure, the update utility
places the Integrated BMC into an update mode, allowing the firmware to load safely onto the
flash device. In the unlikely event the Integrated BMC firmware update process fails due to the
Integrated BMC not being in the proper update state, the server board provides an Integrated
BMC Force Update jumper (J1A2), which forces the Integrated BMC into the proper update
state. The following procedure should be completed in the event the standard Integrated BMC
firmware update process fails.
1. Power down and remove the AC power cord.
2. Open the server chassis. For instructions, see your server chassis documentation.
3. Move jumper from the default operating position (covering pins 1 and 2) to the enabled
position (covering pins 2 and 3).
4. Close the server chassis.
5. Reconnect the AC cord and power up the server.
6. Perform the Integrated BMC firmware update procedure as documented in the
README.TXT file that is included in the given Integrated BMC firmware update package.
After successful completion of the firmware update process, the firmware update utility
may generate an error stating that the Integrated BMC is still in update mode.
7. Power down and remove the AC power cord.
8. Open the server chassis.
9. Move jumper from the enabled position (covering pins 2 and 3) to the disabled position
(covering pins 1 and 2).
10. Close the server chassis.
11. Reconnect the AC cord and power up the server.
Note: Normal Integrated BMC functionality is disabled with the Force Integrated BMC Update
jumper set to the enabled position. The server should never be run with the Integrated BMC
Force Update jumper set in this position. This jumper setting should only be used when the
standard firmware update process fails. This jumper should remain in the default/disabled
position when the server is running normally.
8.3
ME Force Update Jumper
When performing the standard ME force update procedure, the update utility places the ME into
an update mode, allowing the ME to load safely onto the flash device. In the unlikely event ME
firmware update process fails due to ME not being in the proper update state, the server board
provides an Integrated BMC Force Update jumper (J1F1), which forces the ME into the proper
update state. The following procedure should be completed in the event the standard ME
firmware update process fails.
1.
Power down and remove the AC power cord.
2.
Open the server chassis. For instructions, see your server chassis documentation.
Revision 2.4
Intel order number E65697-010
93
Jumper Blocks
Intel® Server Board S3420GP TPS
3.
Move jumper from the default operating position (covering pins 1 and 2) to the enabled
position (covering pins 2 and 3).
4.
Close the server chassis.
5.
Reconnect the AC cord and power up the server.
6.
Perform the ME firmware update procedure as documented in the README.TXT file
that is included in the given ME firmware update package (same package as BIOS).
7.
Power down and remove the AC power cord.
8.
Open the server chassis.
9.
Move jumper from the enabled position (covering pins 2 and 3) to the disabled position
(covering pins 1 and 2).
10. Close the server chassis.
11. Reconnect the AC cord and power up the server.
8.4
BIOS Recovery Jumper
The following procedure boots the recovery BIOS and flashes the normal BIOS:
1.
2.
3.
4.
Turn off the system power.
Move the BIOS recovery jumper to the recovery state.
Insert a bootable BIOS recovery media containing the new BIOS image files.
Turn on the system power.
The BIOS POST screen will appear displaying the progress, and the system will boot to the EFI
shell. The EFI shell then executes the Startup.nsh batch file to start the flash update process.
The user should then switch off the power and return the recovery jumper to its normal position.
The user should not interrupt the BIOS POST on the first boot after recovery.
When the flash update completes:
1.
2.
3.
4.
5.
Remove the recovery media.
Turn off the system power.
Restore the jumper to its original position.
Turn on the system power.
Re-flash any custom blocks, such as user binary or language blocks.
The system should now boot using the updated system BIOS.
94
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS
9.
Intel® Light Guided Diagnostics
Intel® Light Guided Diagnostics
The server board has several on-board diagnostic LEDs to assist in troubleshooting board-level
issues. This section shows where each LED is located on the server board and describes the
function of each LED.
9.1
System Status LED (For the Intel® Server Board S3420GPLX and
S3420GPLC)
The server board provides a system status indicator LED on the front panel. This indicator LED
has specific states and corresponding interpretation as shown in the following table.
Table 60. Front Panel Status LED Behavior Summary
Color
Off
N/A
State
Criticality
Not ready
Amber
Solid on
Critical, nonrecoverable
Amber
Blink
Non-critical
Green
Solid on
System OK
Green
Blink
Degraded
Revision 2.4
Description
AC power off. If no degraded, non-critical, critical, or nonrecoverable conditions exist.
Fatal alarm – system has failed or shutdown:
Thermtrip asserted.
Non-recoverable temperature threshold asserted.
Non-recoverable voltage threshold asserted.
Power fault/Power Control Failure.
Fan redundancy lost, insufficient system cooling. This does not apply
to non-redundant systems.
Uncorrectable memory error.
Non-fatal alarm – system is likely to fail:
CATERR asserted.
Critical temperature threshold asserted.
Critical voltage threshold asserted.
Critical fan threshold asserted.
VRD hot asserted.
SMI Timeout asserted.
Correctable error threshold has been reached for a failing DDR3
DIMM.
System booted and ready.
System degraded:
Non-critical temperature threshold asserted.
Non-critical voltage threshold asserted.
Non-critical fan threshold asserted.
Fan redundancy lost, sufficient system cooling maintained. This
does not apply to non-redundant systems.
Power supply predictive failure.
Unable to use all of the installed memory (more than one DDR3
DIMM installed).
Correctable error threshold has been reached for a failing DDR3
DIMM on a given channel.
Intel order number E65697-010
95
Intel® Light Guided Diagnostics
9.2
Intel® Server Board S3420GP TPS
Post Code Diagnostic LEDs
During the system boot process, the BIOS executes several platform configuration processes,
each of which is assigned a specific hex POST code number. As each configuration routine is
started, the BIOS displays the POST code on the POST code diagnostic LEDs found on the
back edge of the server board. To assist in troubleshooting a system hang during the POST
process, The diagnostic LEDs can be used to identify the last POST process executed.
Table 61. POST Code Diagnostic LED Location
A
B
C
D
E
96
®
Status LED (For Intel Server Board
S3420GPLX and S3420GPLC)
ID LED
Diagnostic LED #7 (MSB LED)
Diagnostic LED #6
Diagnostic LED #5
F
Diagnostic LED #4
G
H
I
J
Diagnostic LED #3
Diagnostic LED #2
Diagnostic LED #1
Diagnostic LED #0 (LSB LED)
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS
Design and Environmental Specifications
10. Design and Environmental Specifications
10.1 Intel® Server Board S3420GP Design Specifications
The operation of the server board at conditions beyond those shown in the following table may
cause permanent damage to the system. Exposure to absolute maximum rating conditions for
extended periods may affect system reliability.
Table 62. Server Board Design Specifications
1
Operating Temperature
0º C to 55º C (32º F to 131º F)
Non-Operating Temperature
DC Voltage
-40º C to 70º C (-40º F to 158º F)
± 5% of all nominal voltages
Shock (Unpackaged)
Trapezoidal, 50 G, 170 inches/sec
Shock (Packaged)
<20 pounds
20 to <40 pounds
40 to <80 pounds
80 to <100 pounds
100 to <120 pounds
120 pounds
36 inches
30 inches
24 inches
18 inches
12 inches
9 inches
Vibration (Unpackaged)
5 Hz to 500 Hz 3.13 g RMS random
1
®
®
Chassis design must provide proper airflow to avoid exceeding the Intel Xeon processor maximum case
temperature.
Disclaimer Note: Intel Corporation server boards contain a number of high-density VLSI and
power delivery components that need adequate airflow to cool. Intel ensures through its own
chassis development and testing that when Intel server building blocks are used together, the
fully integrated system will meet the intended thermal requirements of these components. It is
the responsibility of the system integrator who chooses not to use Intel developed server
building blocks to consult vendor datasheets and operating parameters to determine the amount
of airflow required for their specific application and environmental conditions. Intel Corporation
cannot be held responsible, if components fail or the server board does not operate correctly
when used outside any of their published operating or non-operating limits.
10.2 Board-level Calculated MTBF
This section provides results of MTBF (Mean Time Between Failures) testing done by a third
party testing facility. MTBF is a standard measure for the reliability and performance of the
board under extreme working conditions. The MTBF was measured at 20000 hours at 35
degrees Celsius.
The following table shows the MTBF for the server boards as configured from the factory;
Product Code
®
Intel Server Board S3420GPLX
®
Intel Server Board S3420GPLC
®
Intel Server Board S3420GPV
Revision 2.4
Calculated MTBF
335000 hours
335000 hours
277139 hours
Intel order number E65697-010
Operating Temperature
35 degrees C
35 degrees C
35 degrees C
97
Design and Environmental Specifications
Intel® Server Board S3420GP TPS
10.3 Server Board Power Requirements
This section provides power supply design guidelines for a system using the Intel® Server Board
S3420GP, including voltage and current specifications, and power supply on/off sequencing
characteristics. The following diagram shows the power distribution implemented on this server
board.
Figure 40. Power Distribution Block Diagram
10.3.1
Processor Power Support
The server board supports the Thermal Design Power (TDP) guideline for Intel® Xeon®
processor. The Flexible Motherboard Guidelines (FMB) were also followed to help determine
the suggested thermal and current design values for anticipating future processor needs. The
following table provides maximum values for Icc, TDP power and TCASE for the Intel® Xeon®
Processor 3400 Series.
Table 63. Intel® Xeon® Processor TDP Guidelines
TDP Power
95 W
98
Maximum TCASE
67.0º C
Icc Maximum
150 A
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS
Design and Environmental Specifications
10.4 Power Supply Output Requirements
This section is for reference purposes only. The intent is to provide guidance to system
designers to determine a power supply for use with this server board. This section specifies the
power supply requirements Intel used to develop a power supply for the Intel® Server System
SR1630GP and SR1630HGP.
The following tables define two power and current ratings for this 350-W power supply. The
combined output power of all outputs should not exceed the rated output power. The power
supply must meet both static and dynamic voltage regulation requirements for the minimum
loading conditions.
Table 64. 350-W Load Ratings
Voltage
+3.3 V
Minimum Continuous
0.2A
14 A
Maximum Continuous
+5 V
+12 V
1.0 A
1.5A
18A
24 A
-12 V
0A
0.3A
+5 VSB
0.1 A
2.0 A
Peak
28A
2.5 A
Notes:
1. Maximum continuous total DC output power should not exceed 350 W.
2. Peak total DC output power should not exceed 400 W.
3. Peak power and peak current loading should be supported for a minimum of 12 seconds.
4. Combined 3.3 V/5 V power should not exceed 100 W.
10.4.1
Grounding
The grounds of the power supply output connector pins provide the power return path. The
output connector ground pins are connected to the safety ground (power supply enclosure).
This grounding is designed to ensure passing the maximum allowed common mode noise levels.
The power supply is provided with a reliable protective earth ground. All secondary circuits are
connected to protective earth ground. Resistance of the ground returns to chassis does not
exceed 1.0 m. This path may be used to carry DC current.
10.4.2
Standby Outputs
The 5 VSB output is present when an AC input greater than the power supply turn on voltage is
applied.
10.4.3
Remote Sense
The power supply has remote sense return (ReturnS) to regulate out ground drops for all output
voltages: +3.3 V, +5 V, +12 V, -12 V, and 5 VSB. The power supply uses remote sense to
regulate out drops in the system for the +3.3 V, +5 V, and 12 V outputs. The power supply must
operate within specification over the full range of voltage drops from the power supply’s output
connector to the remote sense points.
Revision 2.4
Intel order number E65697-010
99
Design and Environmental Specifications
10.4.4
Intel® Server Board S3420GP TPS
Voltage Regulation
The power supply output voltages must stay within the following voltage limits when operating at
steady state and dynamic loading conditions. These limits include the peak-peak ripple/noise.
All outputs are measured with reference to the return remote sense signal (ReturnS).
Table 65. Voltage Regulation Limits
Parameter
+ 3.3 V
Tolerance
- 5%/+5%
Minimum
+3.14
Normal
+3.30
Maximum
+3.46
Units
Vrms
+5V
+ 12 V
- 5%/+5%
+4.75
+5.00
+5.25
Vrms
- 5%/+5%
+11.40
+12.00
+12.60
Vrms
- 12 V
- 10%/+10%
-13.20
-12.00
-10.80
Vrms
+ 5 VSB
- 5%/+5%
+4.75
+5.00
+5.25
Vrms
10.4.5
Dynamic Loading
The output voltages remain within limits for the step loading and capacitive loading specified in
the following table. The load transient repetition rate is tested between 50 Hz and 5 kHz at duty
cycles ranging from 10%-90%. The load transient repetition rate is only a test specification. The
 step load may occur anywhere within the Min load to the Max load conditions.
Table 66. Transient Load Requirements
Output
+3.3 V
Step Load Size
(See note 1)
5.0 A
0.25 A/sec
250 F
+5 V
6.0 A
0.25 A/sec
400 F
12 V
11.0 A
0.25 A/sec
500 F
+5 VSB
0.5 A
0.25 A/sec
20 F
Notes:
1.
10.4.6
Load Slew Rate
Test capacitive Load
Step loads on each 12 V output may happen simultaneously and should be tested that way.
Capacitive Loading
The power supply is stable and meets all requirements with the following capacitive loading
ranges.
Table 67. Capacitve Loading Conditions
Output
+3.3 V
10.4.7
Minimum
100
Maximum
2200
F
Units
+5 V
400
2200
F
+12 V
500
2200
F
-12 V
1
350
F
+5 VSB
20
350
F
Closed-loop Stability
The power supply is unconditionally stable under all line/load/transient load conditions including
capacitive load ranges. A minimum of 45° phase margin and -10 dB-gain margin is required.
The power supply manufacturer provides proof of the unit’s closed-loop stability with local
100
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS
Design and Environmental Specifications
sensing through the submission of Bode plots. Closed-loop stability is ensured at the maximum
and minimum loads as applicable.
10.4.8
Common Mode Noise
The Common Mode noise on any output does not exceed 350 mV pk-pk over the frequency
band of 10 Hz to 20 MHz.


The measurement is made across a 100Ω resistor between each of the DC outputs,
including ground, at the DC power connector and chassis ground (power subsystem
enclosure).
The test setup uses a FET probe such as Tektronix* model P6046 or equivalent.
10.4.9
Ripple/Noise
The maximum allowed ripple/noise output of the power supply is defined in the following table.
This is measured over a bandwidth of 0 Hz to 20 MHz at the power supply output connectors. A
10 F tantalum capacitor is placed in parallel with a 0.1 F ceramic capacitor at the point of
measurement.
Table 68. Ripple and Noise
+3.3 V
50 mVp-p
10.4.10
+5 V
50 mVp-p
+12 V
120 mVp-p
-12 V
120 mVp-p
+5 VSB
50 mVp-p
Timing Requirements
The timing requirements for the power supply operation are as follows:
The output voltages must rise from 10% to within regulation limits (Tvout_rise) within 5 ms
to 70 ms, except for 5 VSB, in which case it is allowed to rise from 1.0 ms to 25 ms.
 The +3.3 V, +5 V, and +12 V output voltages should start to rise approximately at the
same time.
 All outputs must rise monotonically.
 The +5 V output must be greater than the +3.3 V output during any point of the voltage
rise.
 The +5 V output must never be greater than the +3.3 V output by more than 2.25 V.
 Each output voltage should reach regulation within 50 ms (Tvout_on) of each other when
the power supply is turned on.
 Each output voltage should fall out of regulation within 400 msec (Tvout_off) of each other
when the power supply is turned off.
Figure 41 and Figure 42 shows the timing requirements for the power supply being turned on
and off via the AC input with PSON held low and the PSON signal with the AC input applied.

Table 69. Output Voltage Timing
Item
Tvout_rise
Tvout_on
Tvout_off
Revision 2.4
Description
Output voltage rise time from each main output.
All main outputs must be within regulation of each
other within this time.
All main outputs must leave regulation within this
time.
Minimum
1
5.0
Intel order number E65697-010
70
50
Maximum
Units
Msec
Msec
700
Msec
1
101
Design and Environmental Specifications
Intel® Server Board S3420GP TPS
Note:
1.
The 5 VSB output voltage rise time should be from 1.0 ms to 25.0 ms.
Figure 41. Output Voltage Timing
Table 70. Turn On/Off Timing
Item
Tsb_on_delay
Tac_on_delay
Tvout_holdup
Tpwok_holdup
Tpson_on_delay
Tpson_pwok
Tpwok_on
Tpwok_off
Tpwok_low
Tsb_vout
102
Description
Delay from AC being applied to 5 VSB being
within regulation.
Delay from AC being applied to all output voltages
being within regulation.
Duration for which all output voltages stay within
regulation after loss of AC. Measured at 80% of
maximum load.
Delay from loss of AC to de-assertion of PWOK.
Measured at 80% of maximum load.
#
Delay from PSON active to output voltages within
regulation limits.
#
Delay from PSON deactive to PWOK being deasserted.
Delay from output voltages within regulation limits
to PWOK asserted at turn on.
Delay from PWOK de-asserted to output voltages
(3.3 V, 5 V, 12 V, -12 V) dropping out of regulation
limits.
Duration of PWOK being in the de-asserted state
during an off/on cycle using AC or the PSON
signal.
Delay from 5 VSB being in regulation to O/Ps
being in regulation at AC turn on.
Minimum
Maximum
N/A
1500
N/A
2500
21
N/A
20
N/A
5
400
N/A
50
100
500
1
N/A
100
N/A
50
1000
Units
Msec
Msec
Msec
Msec
Msec
Msec
Msec
Msec
Msec
Intel order number E65697-010
Msec
Revision 2.4
Intel® Server Board S3420GP TPS
Item
T5VSB_holdup
Design and Environmental Specifications
Description
Duration for which the 5 VSB output voltage stays
within regulation after loss of AC.
Minimum
70
Maximum
N/A
Units
Msec
Figure 42. Turn On/Off Timing (Power Supply Signals)
10.4.11
Residual Voltage Immunity in Standby Mode
The power supply is immune to any residual voltage placed on its outputs (typically, a leakage
voltage through the system from standby output) up to 500 mV. There is no additional heat
generated nor stressing of any internal components with this voltage applied to any individual
output and all outputs simultaneously. It also does not trip the power supply protection circuits
during turn on.
The residual voltage at the power supply outputs for a no-load condition does not exceed 100
mV when AC voltage is applied and the PSON# signal is de-asserted.
10.4.12
Protection Circuits
Protection circuits inside the power supply should cause only the power supply’s main outputs
to shut down. If the power supply latches off due to a protection circuit tripping, an AC cycle
OFF for 15 seconds and a PSON# cycle HIGH for 1 second should reset the power supply.
10.4.12.1
Over-current Protection (OCP)
The power supply has current limits to prevent the +3.3 V, +5 V, and +12 V outputs from
exceeding the values shown in the following table. If the current limits are exceeded, the power
supply shuts down and latches off. The latch is cleared by toggling the PSON# signal or using
an AC power interruption. The power supply is not damaged from repeated power cycling in this
condition. -12 V and 5 VSB are protected under over-current or shorted conditions so no
damage can occur to the power supply. Auto-recovery feature is a requirement on 5 VSB rail.
Revision 2.4
Intel order number E65697-010
103
Design and Environmental Specifications
Intel® Server Board S3420GP TPS
Table 71. Over-Current Protection (OCP)
Voltage
10.4.12.2
Over Current Limit
Min
Max
21A
27A
+3.3V
+5V
15A
20A
+12V
30A
40A
-12V
0.625A
2A
5VSB
N/A
4A
Over-Voltage Protection (OVP)
The power supply over-voltage protection is locally sensed. The power supply shuts down and
latches off after an over-voltage condition occurs. You can clear this latch by toggling the
PSON# signal or using an AC power interruption. The following table contains the over-voltage
limits. The values are measured at the output of the power supply’s connectors. The voltage
never exceeds the maximum levels when measured at the power pins of the power supply
connector during any single point of fail. The voltage never trips any lower than the minimum
levels when measured at the power pins of the power supply connector.
Exception: +5 VSB rail should be able to recover after an over-voltage condition occurs.
Table 72. Over-voltage Protection (OVP) Limits
104
Output Voltage
+3.3 V
Minimum (V)
3.9
Maximum (V)
4.5
+5 V
+12 V
5.7
13.3
6.2
14.5
-12 V
-13.3
-14.5
+5 VSB
5.7
6.5
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS
Regulatory and Certification Information
11. Regulatory and Certification Information
11.1 Product Regulatory Compliance
Intended Application –This product is to be evaluated and certified as Information Technology
Equipment (ITE), which may be installed in offices, schools, computer rooms, and similar
commercial type locations. The suitability of this product for other product certification
categories and/or environments (such as: medical, industrial, telecommunications, NEBS,
residential, alarm systems, test equipment, etc.), other than an ITE application, will require
further evaluation and may require additional regulatory approvals.
Note: The use and/or integration of telecommunication devices such as modems and/or
wireless devices have not been planned for with respect to these systems. If there is any
change of plan to use such devices, then telecommunication type certifications will require
additional planning. If NEBS compliance is required for system level products, additional
certification planning and design will be required.
11.1.1 Product Safety Compliance

CSA 60950-1 Certification (Canada) or cUL

CE Declaration to EU Low Voltage Directive 2006/95/EC (Europe – EN60950-1)

IEC60950-1 (International) CB Certificate & Report, (report to include all CB country
national deviations)

BSMI Declaration of Conformity (Taiwan)

UL 60950-1 Recognition (USA)
11.1.2 Product EMC Compliance – Class A Compliance
Note: This product requires complying with Class A EMC requirements. However, Intel targets a
10 db margin to support customer enablement.

AS/NZS CISPR 22 Emissions (Australia/New Zealand)

ICES-003 – (Canada)

EN55022 - Emissions (Europe)

EN55024 - Immunity (Europe)

CE – EMC Directive 2004/108/EC (Europe)

CISPR 22 – Emissions (International)

KCC MIC Notice No. 1997-41 (EMC) & 1997-42
(EMI) (Korea)

BSMI CNS13438 Emissions (Taiwan)

FCC – Part 15 Emissions (USA) Verification
Revision 2.4
Intel order number E65697-010
105
Regulatory and Certification Information
Intel® Server Board S3420GP TPS
11.1.3 Certifications/Registrations/Declarations

UL Certification (US/Canada)

CE Declaration of Conformity (CENELEC Europe)

FCC/ICES-003 Class A Attestation (USA/Canada)

C-Tick Declaration of Conformity (Australia)

MED Declaration of Conformity (New Zealand)

BSMI Declaration (Taiwan)

RRL Certification (Korea)

GOST – Listed on one System License (Russia)

Belarus – Listed on one System License (Belarus)

Ecology Declaration (International)
11.1.4 Product Ecology Requirements
Intel restricts the use of banned substances in accordance with world wide product ecology
regulatory requirements. Suppliers Declarations of Conformity to the banned substances must
be obtained from all suppliers; and a Material Declaration Data Sheet (MDDS) must be
produced to illustrate compliance. Due verification of random materials is required as a
screening/audit to verify suppliers declarations.
The server board complies with the following ecology regulatory requirements:

All materials, parts, and subassemblies must not contain restricted materials as defined
in Intel’s Environmental Product Content Specification of Suppliers and Outsourced
Manufacturers – http://supplier.intel.com/ehs/environmental.htm.

Europe - European Directive 2002/95/EC - Restriction of Hazardous Substances (RoHS)
Threshold limits and banned substances are noted below.
Quantity limit of 0.1% by mass (1000 PPM) for Lead, Mercury, Hexavalent Chromium,
Polybrominated Biphenyls Diphenyl Ethers (PBB/PBDE)
Quantity limit of 0.01% by mass (100 PPM) for Cadmium
 China RoHS
106

All plastic parts that weigh >25gm shall be marked with the ISO11469 requirements for
recycling. Example >PC/ABS<

EU Packaging Directive

CA. Lithium Perchlorate insert Perchlorate Material – Special handling may apply. Refer
to http://www.dtsc.ca.gov/hazardouswaste/perchlorate.
This notice is required by California Code of Regulations, Title 22, Division 4.5, Chapter
33: Best Management Practices for Perchlorate Materials. This product/part includes a
battery which contains Perchlorate material.

German Green Dot

Japan Recycling
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS
Regulatory and Certification Information
11.2 Product Regulatory Compliance Markings
The server board is provided with the following regulatory marks.
Regulatory Compliance
UL Mark
Region
USA/Canada
CE Mark
Europe
EMC Marking (Class A)
Canada
BSMI Marking (Class A)
Taiwan
Marking
CANADA ICES-003 CLASS A
D33025
C-tick Marking
Australia/New Zealand
RRL MIC Mark
Korea
Country of Origin
Exporting Requirements
MADE IN xxxxx (Provided by label, not silk
screen)
Model Designation
Regulatory Identification
S3420GP
PB Free Marking?
Environmental
Requirements
China
N232
인증번호: CPU-S3420GP (A)
China RoHS Marking
China Recycling Package
Marking
(Marked on packaging
label)
Revision 2.4
Refer to Jedec Standard J-STD609
China
Intel order number E65697-010
107
Regulatory and Certification Information
Intel® Server Board S3420GP TPS
Regulatory Compliance
Other Recycling Package
Marking
(Marked on packaging
label)
Region
Other Recycling
Package Marks
Other Recycling Package
Marking
(Marked on packaging
label)
CA. Lithium Perchlorate
insert
108
Marking
Perchlorate Material – Special handling may
apply. See
www.dtsc.ca.gov/hazardouswaste/perchlorate
This notice is required by California Code of
Regulations, Title 22, Division 4.5, Chapter 33:
Best Management Practices for Perchlorate
Materials. This product/part includes a battery
which contains Perchlorate material.
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS
Regulatory and Certification Information
11.3 Electromagnetic Compatibility Notices
11.3.1 FCC Verification Statement (USA)
This device complies with Part 15 of the FCC Rules. Operation is subject to two conditions: (1)
This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
Intel Corporation
5200 N.E. Elam Young Parkway
Hillsboro, OR 97124-6497
Phone: 1-800-628-8686
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct the interference by one or
more of these measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and the receiver.

Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.

Consult the dealer or an experienced radio/TV technician for help.
Any changes or modifications not expressly approved by the grantee of this device could void
the user’s authority to operate the equipment. The customer is responsible for ensuring
compliance of the modified product.
All cables used to connect to peripherals must be shielded and grounded. Operation with cables,
connected to peripherals that are not shielded and grounded may result in interference to radio
and TV reception.
Revision 2.4
Intel order number E65697-010
109
Regulatory and Certification Information
Intel® Server Board S3420GP TPS
11.3.2 ICES-003 (Canada)
Cet appareil numérique respecte les limites bruits radioélectriques applicables aux
appareils numériques de Classe B prescrites dans la norme sur le matériel brouilleur:
“Appareils Numériques”, NMB-003 édictée par le Ministre Canadian des Communications.
English translation of the notice above:
This digital apparatus does not exceed the Class B limits for radio noise emissions from digital
apparatus set out in the interference-causing equipment standard entitled “Digital Apparatus,”
ICES-003 of the Canadian Department of Communications.
11.3.3 Europe (CE Declaration of Conformity)
This product has been tested in accordance too, and complies with the Low Voltage Directive
(73/23/EEC) and EMC Directive (89/336/EEC). The product has been marked with the CE Mark
to illustrate its compliance.
11.3.4 VCCI (Japan)
English translation of the notice above:
This is a Class B product based on the standard of the Voluntary Control Council for
Interference (VCCI) from Information Technology Equipment. If this is used near a radio or
television receiver in a domestic environment, it may cause radio interference. Install and use
the equipment according to the instruction manual.
110
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS
Regulatory and Certification Information
11.3.5 BSMI (Taiwan)
The BSMI Certification Marking and EMC warning is located on the outside rear area of the
product.
11.3.6 RRL (Korea)
Following is the RRL certification information for Korea.
English translation of the notice above:
1.
2.
3.
4.
5.
Type of Equipment (Model Name): On License and Product
Certification No.: On RRL certificate. Obtain certificate from local Intel representative
Name of Certification Recipient: Intel Corporation
Date of Manufacturer: Refer to date code on product
Manufacturer/Nation: Intel Corporation/Refer to country of origin marked on product
Revision 2.4
Intel order number E65697-010
111
Appendix A: Integration and Usage Tips
Intel® Server Board S3420GP TPS
Appendix A: Integration and Usage Tips

When adding or removing components or peripherals from the server board, AC power
must be removed. With AC power plugged into the server board, 5-Volt standby is still
present even though the server board is powered off.

Supports only Intel® Xeon® Processor 3400 Series with 95 W and less Thermal Design
Power (TDP). Does not support previous generations of the Intel® Xeon® processor.

On the back edge of the server board are diagnostic LEDs that display a sequence of
amber POST codes during the boot process. If the server board hangs during POST, the
LEDs displays the last POST event run before the hang.

Supports only registered DDR3 DIMMs (RDIMMs) and unbuffered DDR3 DIMMs
(UDIMMs). Does not support the mixing of RDIMMs and UDIMMs.

For the best performance, the number of DDR3 DIMMs installed should be balanced
across both processor sockets and memory channels. For example, a two-DIMM
configuration performs better than a one-DIMM configuration. In a two-DIMM
configuration, DIMMs should be installed in DIMM sockets A1 and A2. A six-DIMM
configuration (DIMM socketsA1, A2, A3, B1, B2 and B3) performs better than a threeDIMM configuration (DIMM sockets A1, A2, and A3).

The Intel® Remote Management Module 3 (Intel® RMM3) connector is not compatible
with the Intel® Remote Management Module (Product Order Code - AXXRMM) or Intel®
Remote Management Module 2 (Product Order Code - AXXRMM2).

Clear the CMOS with the AC power cord plugged in. Removing the AC power before
performing the CMOS clear operation causes the system to automatically power up and
immediately power down after the CMOS clear procedure is followed and AC power is
re-applied. If this happens, remove the AC power cord, wait 30 seconds, and then reconnect the AC power cord. Power up the system and proceed to the <F2> BIOS Setup
utility to reset the needed settings.

Normal Integrated BMC functionality is disabled with the force Integrated BMC update
jumper set to the “enabled” position (pins 2-3). The server should never be run with the
Integrated BMC force update jumper set in this position and should only be used when
the standard firmware update process fails. This jumper should remain in the default
(disabled) position (pins 1-2) when the server is running normally.
When performing a normal BIOS update procedure, the BIOS recovery jumper must be
set to its default position (pins 1-2).

112
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS
Appendix B: Integrated BMC Sensor Tables
Appendix B: Integrated BMC Sensor Tables
This appendix lists the sensor identification numbers and information about the sensor type,
name, supported thresholds, assertion and de-assertion information, and a brief description of
the sensor purpose. See the Intelligent Platform Management Interface Specification, Version
2.0, for sensor and event/reading-type table information.

Sensor Type
The Sensor Type values are the values enumerated in the Sensor Type Codes table in
the IPMI specification. The Sensor Type provides the context in which to interpret the
sensor, such as the physical entity or characteristic that is represented by this sensor.

Event/Reading Type
The Event/Reading Type values are from the Event/Reading Type Code Ranges and
Generic Event/Reading Type Codes tables in the IPMI specification. Digital sensors are
a specific type of discrete sensor, which have only two states.

Event Offset/Triggers
Event Thresholds are event-generating thresholds for threshold types of sensors.
[u,l][nr,c,nc]: upper non-recoverable, upper critical, upper non-critical, lower nonrecoverable, lower critical, lower non-critical
- uc, lc: upper critical, lower critical
Event Triggers are supported event-generating offsets for discrete type sensors. The
offsets can be found in the Generic Event/Reading Type Codes or Sensor Type Codes
tables in the IPMI specification, depending on whether the sensor event/reading type is
generic or a sensor-specific response.
-

Assertion/De-assertion Enables
Assertion and de-assertion indicators reveal the type of events the sensor generates:

- As: Assertions
- De: De-assertion
Readable Value/Offsets

Readable Value indicates the type of value returned for threshold and other nondiscrete type sensors.
- Readable Offsets indicate the offsets for discrete sensors that are readable with the
Get Sensor Reading command. Unless otherwise indicated, all event triggers are
readable; Readable Offsets consist of the reading type offsets that do not generate
events.
Event Data
-
Event data is the data that is included in an event message generated by the sensor. For
threshold-based sensors, the following abbreviations are used:
-
Revision 2.4
R: Reading value
T: Threshold value
Intel order number E65697-010
113
Appendix B: Integrated BMC Sensor Tables

Intel® Server Board S3420GP TPS
Rearm Sensors
The rearm is a request for the event status for a sensor to be rechecked and updated
upon a transition between good and bad states. Rearming the sensors can be done
manually or automatically. This column indicates the type supported by the sensor. The
following abbreviations are used to describe a sensor:

- A: Auto-rearm
- M: Manual rearm
Default Hysteresis
The hysteresis setting applies to all thresholds of the sensor. This column provides the
count of hysteresis for the sensor, which can be 1 or 2 (positive or negative hysteresis).

Criticality
Criticality is a classification of the severity and nature of the condition. It also controls the
behavior of the Control Panel Status LED

Standby
Some sensors operate on standby power. These sensors may be accessed and/or
generate events when the main (system) power is off, but AC power is present.
114
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS
Appendix B: Integrated BMC Sensor Tables
Table 73. Integrated BMC Core Sensors
Sensor Name3
Sensor #
Platform
Applicability
Sensor Type
Event /
Reading
Type
Event Offset
Triggers
00 - Timer
expired, status
only
IPMI Watchdog
03h
All
Watchdog 2
23h
Sensor
Specific
6Fh
Contrib. To
System
Status
OK
Assert /
Deassert
Readable
Value /
Offsets
Event
Data
Rearm
Standby
As
–
A
X
As and
De
–
Trig Offset
A
As
–
Trig Offset
A
–
As
–
Trig Offset
A
X
As
-
Trig Offset
A,I
X
As and
De
Analog
R, T
A
–
01 - Hard reset
02 - Power
down
Trig Offset
03 - Power
cycle
08 - Timer
interrupt
Physical Scrty
FP Interrupt
(NMI)
System Event Log
04h
05h
07h
Chassis
Intrusion is
chassisspecific
All
All
Physical
Security
Sensor
Specific
05h
6Fh
Critical
Interrupt
Sensor
Specific
13h
6Fh
Event
Logging
Disabled
Sensor
Specific
10h
System Event
(System Event)
BB +1.05 PCH
Revision 2.4
08h
10h
All
All
6Fh
System
Event
Sensor
Specific
12h
6Fh
Voltage
02h
Threshold
01h
00 - Chassis
intrusion
OK
04 - LAN least
lost
Degraded
00 - Front
panel
NMI/diagnostic
interrupt
OK
02 - Log area
reset/cleared
04 – PEF
action
[u,l] [c,nc]
Intel order number E65697-010
OK
X
OK
nc =
Degraded
c = Nonfatal
115
Appendix B: Integrated BMC Sensor Tables
Sensor Name3
BB +1.1V P1 Vccp
BB +1.1V P2 Vccp
BB +1.5V P1 DDR3
BB +1.5V P2 DDR3
BB +1.8V AUX
BB +3.3V
Sensor #
11h
12h
13h
14h
15h
16h
Platform
Applicability
Intel® Server Board S3420GP TPS
Sensor Type
Event /
Reading
Type
All
Voltage
02h
Threshold
01h
All
Voltage
02h
Threshold
01h
All
Voltage
02h
Threshold
01h
All
Voltage
02h
Threshold
01h
All
Voltage
02h
Threshold
01h
All
Voltage
02h
Threshold
01h
Threshold
01h
[u,l] [c,nc]
Generic
01 - Limit
exceeded
BB +3.3V STBY
17h
All
Voltage
02h
BB Vbat
18h
All
Voltage
02h
116
05h
Event Offset
Triggers
[u,l] [c,nc]
[u,l] [c,nc]
[u,l] [c,nc]
[u,l] [c,nc]
[u,l] [c,nc]
[u,l] [c,nc]
Intel order number E65697-010
Contrib. To
System
Status
nc =
Degraded
c = Nonfatal
nc =
Degraded
c = Nonfatal
nc =
Degraded
c = Nonfatal
nc =
Degraded
c = Nonfatal
nc =
Degraded
c = Nonfatal
nc =
Degraded
c = Nonfatal
nc =
Degraded
c = Nonfatal
Non-fatal
Assert /
Deassert
Readable
Value /
Offsets
Event
Data
Rearm
Standby
As and
De
Analog
R, T
A
–
As and
De
Analog
R, T
A
–
As and
De
Analog
R, T
A
–
As and
De
Analog
R, T
A
–
As and
De
Analog
R, T
A
X
As and
De
Analog
R, T
A
–
As and
De
Analog
R, T
A
X
As and
De
–
Trig Offset
A
X
Revision 2.4
Intel® Server Board S3420GP TPS
Appendix B: Integrated BMC Sensor Tables
Sensor Name3
Sensor #
Platform
Applicability
BB +5.0V
19h
BB +5.0V STBY
BB +12.0V
BB -12.0V
Server board Temp
1Ah
1Bh
1Ch
20h
Sensor Type
Event /
Reading
Type
All
Voltage
02h
Threshold
01h
All
Voltage
02h
Threshold
01h
All
Voltage
02h
Threshold
01h
All
Voltage
02h
Threshold
01h
Temperatur
e
Threshold
All
01h
Front panel temp
21h
All
Temperatur
e
01h
PCH Thermal Margin
22h
All
Temperatur
e
01h
Processor MEMTHRM
MRGN
23h
All
Temperatur
e
01h
Revision 2.4
01h
Threshold
01h
Threshold
01h
Threshold
01h
Event Offset
Triggers
[u,l] [c,nc]
[u,l] [c,nc]
[u,l] [c,nc]
[u,l] [c,nc]
[u,l] [c,nc]
[u,l] [c,nc]
Contrib. To
System
Status
nc =
Degraded
c = Nonfatal
nc =
Degraded
c = Nonfatal
nc =
Degraded
c = Nonfatal
nc =
Degraded
c = Nonfatal
nc =
Degraded
c = Nonfatal
nc =
Degraded
c = Nonfatal
Assert /
Deassert
Readable
Value /
Offsets
Event
Data
Rearm
Standby
As and
De
Analog
R, T
A
–
As and
De
Analog
R, T
A
X
As and
De
Analog
R, T
A
–
As and
De
Analog
R, T
A
–
As and
De
Analog
R, T
A
X
As and
De
Analog
R, T
A
X
-
-
-
Analog
-
-
-
-
-
-
Analog
-
-
-
Intel order number E65697-010
117
Appendix B: Integrated BMC Sensor Tables
Intel® Server Board S3420GP TPS
Sensor Name3
Sensor #
Platform
Applicability
Sensor Type
Event /
Reading
Type
Fan Tach Sensors
30h–
34h
Chassisspecific
Fan
Threshold
04h
01h
Processor Therm
Margin
62h
All
Temperatur
e
Threshold
Processor Therm Ctrl %
64h
01h
All
Temperatur
e
01h
Processor VRD Temp
CATERR
PCH Thermal Trip
118
66h
68h
6Ah
All
All
All
01h
Threshold
01h
Temperatur
e
Digital
Discrete
01h
05h
Processor
Digital
Discrete
07h
03h
Temperatur
e
Digital
Discrete
01h
03h
Event Offset
Triggers
[l] [c,nc]
Contrib. To
System
Status
nc =
Degraded
c = Non2
fatal
Assert /
Deassert
Readable
Value /
Offsets
Event
Data
Rearm
As and
De
Analog
R, T
M
Standby
–
–
–
Analog
–
–
–
[u] [c]
Non-fatal
As and
De
Analog
Trig Offset
A
–
01 - Limit
exceeded
Fatal
As and
De
–
Trig Offset
M
–
01 – State
Asserted
Non-fatal
As and
De
–
Trig Offset
M
–
01 – State
Asserted
Fatal
As and
De
–
Trig Offset
M
–
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS
Appendix C: POST Code Diagnostic LED Decoder
Appendix C: POST Code Diagnostic LED Decoder
During the system boot process, the BIOS executes a number of platform configuration
processes, each of which is assigned a specific hex POST code number. As each configuration
routine is started, the BIOS displays the POST code to the POST Code Diagnostic LEDs on the
back edge of the server board. To assist in troubleshooting a system hang during the POST
process, you can use the diagnostic LEDs to identify the last POST process executed.
Each POST code is represented by the eight amber diagnostic LEDs. The POST codes are
divided into two nibbles: an upper nibble and a lower nibble. The upper nibble bits are
represented by diagnostic LEDs #4, #5, #6, and #7. The lower nibble bits are represented by
diagnostics LEDs #0, #1, #2, and #3. If the bit is set in the upper and lower nibbles, then the
corresponding LED is lit. If the bit is clear, then the corresponding LED is off.
The diagnostic LED #7 is labeled as “MSB”, and the diagnostic LED #0 is labeled as “LSB”.
Figure 43. Diagnostic LED Placement Diagram
In the following example, the BIOS sends a value of ACh to the diagnostic LED decoder. The
LEDs are decoded as follows:
Table 74. POST Progress Code LED Example
Upper Nibble LEDs
LEDs
Status
Results

Lower Nibble LEDs
MSB
LED #7
8h
LED #6
4h
LED #5
2h
LED #4
1h
LED #3
8h
LED #2
4h
LED #1
2h
LSB
LED #0
1h
ON
OFF
ON
OFF
ON
OFF
ON
OFF
1
0
1
0
1
1
0
0
Ah
Ch
Upper nibble bits = 1010b = Ah; Lower nibble bits = 1100b = Ch; the two are
concatenated as ACh.
Revision 2.4
Intel order number E65697-010
119
Appendix C: POST Code Diagnostic LED Decoder
Intel® Server Board S3420GP TPS
Table 75. Diagnostic LED POST Code Decoder
Diagnostic LED Decoder
O = On, X=Off
Upper Nibble
Lower Nibble
Checkpoint
MSB
8h
LED
#7
Host Processor
0x04h
X
0x10h
X
0x11h
X
0x12h
X
0x13h
X
Chipset
0x21h
X
Memory
0x22h
X
0x23h
X
0x24h
X
0x25h
X
0x26h
X
0x27h
X
0x28h
X
PCI Bus
0x50h
X
0x51h
X
0x52h
X
0x53h
X
0x54h
X
0x55h
X
0x56h
X
0x57h
X
USB
0x58h
X
0x59h
X
ATA/ATAPI/SATA
0x5Ah
X
0x5Bh
X
0x5Ch
X
0x5Dh
X
SMBUS
0x5Eh
X
0x5Fh
X
Local Console
0x70h
X
0x71h
X
0x72h
X
Remote Console
120
4h
#6
2h
#5
1h
#4
8h
#3
4h
#2
2h
#1
Description
LSB
1h
#0
X
X
X
X
X
X
X
X
X
X
X
O
O
O
O
X
X
X
X
X
O
X
X
X
X
X
X
X
O
O
X
X
O
X
O
Early processor initialization (flat32.asm) where system BSP is selected
X
O
X
X
X
X
O
Initializing a chipset component
X
X
X
X
X
X
X
O
O
O
O
O
O
O
X
X
X
X
X
X
X
X
X
X
X
X
X
O
X
X
O
O
O
O
X
O
O
X
X
O
O
X
X
O
X
O
X
O
X
Reading configuration data from memory (SPD on FBDIMM)
Detecting presence of memory
Programming timing parameters in the memory controller
Configuring memory parameters in the memory controller
Optimizing memory controller settings
Initializing memory, such as ECC init
Testing memory
O
O
O
O
O
O
O
O
X
X
X
X
X
X
X
X
O
O
O
O
O
O
O
O
X
X
X
X
X
X
X
X
X
X
X
X
O
O
O
O
X
X
O
O
X
X
O
O
X
O
X
O
X
O
X
O
Enumerating PCI buses
Allocating resources to PCI buses
Hot Plug PCI controller initialization
Reserved for PCI bus
Reserved for PCI bus
Reserved for PCI bus
Reserved for PCI bus
Reserved for PCI bus
O
X
O
O
X
X
X
O
X
O
O
X
X
O
Resetting USB bus
Reserved for USB devices
O
O
O
O
X
X
X
X
O
O
O
O
O
O
O
O
X
X
O
O
O
O
X
X
X
O
X
O
Resetting SATA bus and all devices
Detecting the presence of ATA device
Enable SMART if supported by ATA device
Reserved for ATA
O
O
X
X
O
O
O
O
O
O
O
O
X
O
Resetting SMBUS
Reserved for SMBUS
O
O
O
O
O
O
O
O
O
X
X
X
X
X
X
X
X
O
X
O
X
Resetting the video controller (VGA)
Disabling the video controller (VGA)
Enabling the video controller (VGA)
Power-on initialization of the host processor (Boot Strap Processor)
Host processor cache initialization (including AP)
Starting application processor initialization
SMM initialization
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS
Appendix C: POST Code Diagnostic LED Decoder
Diagnostic LED Decoder
O = On, X=Off
Upper Nibble
Lower Nibble
Checkpoint
MSB
8h 4h
LED
#7 #6
0x78h
X
O
0x79h
X
O
0x7Ah
X
O
Keyboard (only USB)
0x90h
O
X
0x91h
O
X
0x92h
O
X
0x93h
O
X
0x94h
O
X
0x95h
O
X
Mouse (only USB)
0x98h
O
X
0x99h
O
X
0x9Ah
O
X
0x9Bh
O
X
Fixed Media
0xB0h
O
X
0xB1h
O
X
LSB
2h 1h 8h 4h 2h 1h
#5 #4 #3 #2 #1 #0
O
O
O
X
X
X
Resetting the console controller
O
O
O
X
X
O
Disabling the console controller
O
O
O
X
O
X
Enabling the console controller
X
X
X
X
X
X
X
X
X
X
O
O
X
X
O
O
X
X
X
O
X
O
X
O
Resetting the keyboard
Disabling the keyboard
Detecting the presence of the keyboard
Enabling the keyboard
Clearing keyboard input buffer
Reserved for keyboard
X
X
X
O X
O
X
O
X
X
X
O
O
O
O
O
O
X
O
X
O
Resetting the mouse
Detecting the mouse
Detecting the presence of mouse
Enabling the mouse
O
O
O
O
X
X
X
X
X
X
X
O
X
O
O
X
X
O
X
0xB3h
O
X
Removable Media
0xB8h
O
X
0xB9h
O
X
O
O
X
X
O
O
Resetting fixed media device
Disabling fixed media device
Detecting presence of a fixed media device (SATA hard drive detection,
etc.)
Enabling/configuring a fixed media device
O
O
O
O
O
O
X
X
X
X
X
O
0xBAh
O
O
O
X
O
X
0xBCh
O
X
O
O
O
O
Boot Device Selection (BDS)
0xD0
O
O
X
O
X
X
0xD1
O
O
X
O
X
X
0xD2
O
O
X
O
X
X
0xD3
O
O
X
O
X
X
0xD4
O
O
X
O
X
O
0xD5
O
O
X
O
X
O
0xD6
O
O
X
O
X
O
0xDF
O
O
X
O
O
O
Pre-EFI Initialization (PEI) Core
0xE0h
O
O
O
X
X
X
0xE1h
O
O
O
X
X
X
0xE2h
O
O
O
X
X
X
0xE3h
O
O
O
X
X
X
Driver eXecution Environment (DXE) Core
0xE4h
O
O
O
X
X
O
0xE5h
O
O
O
X
X
O
X
X
Resetting removable media device
Disabling removable media device
Detecting presence of a removable media device (SATA CDROM
detection, etc.)
Enabling/configuring a removable media device
X
X
O
O
X
X
O
O
X
O
X
O
X
O
X
O
Entered the Boot Device Selection phase (BDS)
Return to last good boot device
Setup boot device selection policy
Connect boot device controller
Attempt flash update boot mode
Transfer control to EFI boot
Trying to boot device selection
Reserved for boot device selection
X
X
O
O
X
O
X
O
Entered Pre-EFI Initialization phase (PEI)
Started dispatching early initialization modules (PEIM)
Initial memory found, configured, and installed correctly
Transfer control to the DXE Core
X
X
X
O
Entered EFI driver execution phase (DXE)
Started dispatching drivers
0xB2h
Revision 2.4
O
O
X
X
X
X
X
X
X
O
O
O
O
O
O
Description
X
O
X
Intel order number E65697-010
121
Appendix C: POST Code Diagnostic LED Decoder
Intel® Server Board S3420GP TPS
Diagnostic LED Decoder
O = On, X=Off
Upper Nibble
Lower Nibble
Checkpoint
MSB
LSB
8h 4h 2h 1h 8h 4h 2h 1h
#7 #6 #5 #4 #3 #2 #1 #0
Started connecting drivers
O
O
O
X
X
O
O
X
LED
0xE6h
DXE Drivers
0xE7h
O
O
O
X
O
O
0xE8h
O
O
O
X
O
X
0xE9h
O
O
O
X
O
X
0xEAh
O
O
O
X
O
O
0xEEh
O
O
O
X
O
O
0xEFh
O
O
O
X
O
O
Pre-EFI Initialization Module (PEIM)/Recovery
0x30h
X
X
O
O
X
X
0x31h
X
X
O
O
X
X
0x34h
X
X
O
O
X
O
0x35h
X
X
O
O
X
O
0x3Fh
X
X
O
O
O
O
Runtime Phase/EFI Operating System Boot
X
X
X
X
X
X
O
X
O
X
X
O
Waiting for user input
Checking password
Entering BIOS setup
Flash Update
Calling Int 19. One beep unless silent boot is enabled.
Unrecoverable boot failure
X
X
X
X
O
X
O
X
O
O
Crisis recovery has been initiated because of a user request
Crisis recovery has been initiated by software (corrupt flash)
Loading crisis recovery capsule
Handing off control to the crisis recovery capsule
Crisis recovery capsule failed integrity check of capsule descriptors
Signal that the OS has switched to virtual memory mode
Entering the sleep state
Exiting the sleep state
Operating system has requested EFI to close boot services has been
cancelled.
0XF2h
0XF4h
0XF5h
O
O
O
O
O
O
O
O
O
O
O
O
X
X
X
X
O
O
O
X
X
X
X
O
0XF8h
O
O
O
O
O
X
X
X
Progress Code
0XF9h
O
0xFAh
O
X
X
X
X
O
O
X
X
X
X
X
X
X
O
122
Description
Resetting the keyboard
Disabling the keyboard
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS
Appendix D: POST Code Errors
Appendix D: POST Code Errors
Whenever possible, the BIOS outputs the current boot progress codes on the video screen.
Progress codes are 32-bit quantities plus optional data. The 32-bit numbers include class,
subclass, and operation information. The class and subclass fields point to the type of hardware
that is being initialized. The operation field represents the specific initialization activity. Based on
the data bit availability to display progress codes, a progress code can be customized to fit the
data width. The higher the data bit, the higher the granularity of information that can be sent on
the progress port. The progress codes may be reported by the system BIOS or option ROMs.
The Response section in the following table is divided into three types:



No Pause: The message displays on the screen during POST or in the Error Manager.
The system continues booting with a degraded state. The user may want to replace the
erroneous unit. The setup POST error Pause setting does not have any effect with this
error.
Pause: The message displays on the Error Manager screen, and an error is logged to
the SEL. The setup POST error Pause setting determines whether the system pauses to
the Error Manager for this type of error, where the user can take immediate corrective
action or choose to continue booting.
Halt: The message displays on the Error Manager screen, an error is logged to the SEL,
and the system cannot boot unless the error is resolved. The user must replace the
faulty part and restart the system. The setup POST error Pause setting does not have
any effect with this error.
Table 76. POST Error Messages and Handling
Error Code
0012
CMOS date/time not set
Error Message
Pause
Response
0048
Password check failed
Halt
0108
0109
Keyboard component encountered a locked error.
Keyboard component encountered a stuck key error.
No Pause
No Pause
0113
Fixed Media The SAS RAID firmware cannot run properly. The user should attempt to
reflash the firmware.
Pause
0140
PCI component encountered a PERR error.
Pause
0141
PCI resource conflict
Pause
0146
PCI out of resources error
Pause
0192
L3 cache size mismatch
Halt
0194
0195
CPUID, processor family are different
Front side bus mismatch
Halt
Pause
0196
Processor Model mismatch
Pause
0197
Processor speeds mismatched
Pause
0198
Processor family is unsupported.
Pause
019F
5220
Processor and chipset stepping configuration is unsupported.
CMOS/NVRAM Configuration Cleared
Pause
Pause
5221
Passwords cleared by jumper
Pause
5224
Password clear Jumper is Set.
Pause
8110
Processor 01 internal error (IERR) on last boot
Pause
8111
Processor 02 internal error (IERR) on last boot
Pause
Revision 2.4
Intel order number E65697-010
123
Appendix D: POST Code Errors
Intel® Server Board S3420GP TPS
Error Code
8120
Error Message
Processor 01 thermal trip error on last boot
Pause
Response
8121
8130
Processor 02 thermal trip error on last boot
Processor 01 disabled
Pause
Pause
8131
Processor 02 disabled
Pause
8140
Processor 01 Failed FRB-3 Timer.
No Pause
8141
Processor 02 Failed FRB-3 Timer.
No Pause
8160
8161
Processor 01 unable to apply BIOS update
Processor 02 unable to apply BIOS update
Pause
Pause
8170
Processor 01 failed Self Test (BIST).
Pause
8171
Processor 02 failed Self Test (BIST).
Pause
8180
Processor 01 BIOS does not support the current stepping for processor
No Pause
8181
Processor 02 BIOS does not support the current stepping for processor
No Pause
8190
8198
Watchdog timer failed on last boot
Operating system boot watchdog timer expired on last boot
Pause
Pause
8300
Integrated Baseboard Management Controller failed self-test
Pause
84F2
Integrated Baseboard Management Controller failed to respond
Pause
84F3
Integrated Baseboard Management Controller in update mode
Pause
84F4
84FF
Sensor data record empty
System event log full
Pause
No Pause
8500
Memory component could not be configured in the selected RAS mode.
Pause
8520
DIMM_A1 failed Self Test (BIST).
Pause
8521
DIMM_A2 failed Self Test (BIST).
Pause
8522
8523
DIMM_A3 failed Self Test (BIST).
DIMM_A4 failed Self Test (BIST).
Pause
Pause
8524
DIMM_B1 failed Self Test (BIST).
Pause
8525
DIMM_B2 failed Self Test (BIST).
Pause
8526
DIMM_B3 failed Self Test (BIST).
Pause
8527
DIMM_B4 failed Self Test (BIST).
Pause
8528
8529
DIMM_C1 failed Self Test (BIST).
DIMM_C2 failed Self Test (BIST).
Pause
Pause
852A
DIMM_C3 failed Self Test (BIST).
Pause
852B
DIMM_C4 failed Self Test (BIST).
Pause
852C
DIMM_D1 failed Self Test (BIST).
Pause
852D
852E
DIMM_D2 failed Self Test (BIST).
DIMM_D3 failed Self Test (BIST).
Pause
Pause
852F
DIMM_D4 failed Self Test (BIST).
Pause
8540
DIMM_A1 Disabled.
Pause
8541
DIMM_A2 Disabled.
Pause
8542
8543
DIMM_A3 Disabled.
DIMM_A4 Disabled.
Pause
Pause
8544
DIMM_B1 Disabled.
Pause
8545
DIMM_B2 Disabled.
Pause
8546
DIMM_B3 Disabled.
Pause
8547
DIMM_B4 Disabled.
Pause
8548
8549
DIMM_C1 Disabled.
DIMM_C2 Disabled.
Pause
Pause
854A
DIMM_C3 Disabled.
Pause
124
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS
Appendix D: POST Code Errors
Error Code
854B
DIMM_C4 Disabled.
Error Message
Pause
854C
854D
DIMM_D1 Disabled.
DIMM_D2 Disabled.
Pause
Pause
854E
DIMM_D3 Disabled.
Pause
854F
DIMM_D4 Disabled.
Pause
8560
DIMM_A1 Component encountered a Serial Presence Detection (SPD) fail error.
Pause
8561
8562
DIMM_A2 Component encountered a Serial Presence Detection (SPD) fail error.
DIMM_A3 Component encountered a Serial Presence Detection (SPD) fail error.
Pause
Pause
8563
DIMM_A4 Component encountered a Serial Presence Detection (SPD) fail error.
Pause
8564
DIMM_B1 Component encountered a Serial Presence Detection (SPD) fail error.
Pause
8565
DIMM_B2 Component encountered a Serial Presence Detection (SPD) fail error.
Pause
8566
DIMM_B3 Component encountered a Serial Presence Detection (SPD) fail error.
Pause
8567
8568
DIMM_B4 Component encountered a Serial Presence Detection (SPD) fail error.
DIMM_C1 Component encountered a Serial Presence Detection (SPD) fail error.
Pause
Pause
8569
DIMM_C2 Component encountered a Serial Presence Detection (SPD) fail error.
Pause
856A
DIMM_C3 Component encountered a Serial Presence Detection (SPD) fail error.
Pause
856B
DIMM_C4 Component encountered a Serial Presence Detection (SPD) fail error.
Pause
856C
856D
DIMM_D1 Component encountered a Serial Presence Detection (SPD) fail error.
DIMM_D2 Component encountered a Serial Presence Detection (SPD) fail error.
Pause
Pause
856E
DIMM_D3 Component encountered a Serial Presence Detection (SPD) fail error.
Pause
856F
DIMM_D4 Component encountered a Serial Presence Detection (SPD) fail error.
Pause
8580
DIMM_A1 Correctable ECC error encountered.
Pause after 10 occurrences
8581
8582
DIMM_A2 Correctable ECC error encountered.
DIMM_A3 Correctable ECC error encountered.
Pause after 10 occurrences
Pause after 10 occurrences
8583
DIMM_A4 Correctable ECC error encountered.
Pause after 10 occurrences
8584
DIMM_B1 Correctable ECC error encountered.
Pause after 10 occurrences
8585
DIMM_B2 Correctable ECC error encountered.
Pause after 10 occurrences
8586
DIMM_B3 Correctable ECC error encountered.
Pause after 10 occurrences
8587
8588
DIMM_B4 Correctable ECC error encountered.
DIMM_C1 Correctable ECC error encountered.
Pause after 10 occurrences
Pause after 10 occurrences
8589
DIMM_C2 Correctable ECC error encountered.
Pause after 10 occurrences
858A
DIMM_C3 Correctable ECC error encountered.
Pause after 10 occurrences
858B
DIMM_C4 Correctable ECC error encountered.
Pause after 10 occurrences
858C
858D
DIMM_D1 Correctable ECC error encountered.
DIMM_D2 Correctable ECC error encountered.
Pause after 10 occurrences
Pause after 10 occurrences
858E
DIMM_D3 Correctable ECC error encountered.
Pause after 10 occurrences
858F
DIMM_D4 Correctable ECC error encountered.
Pause after 10 occurrences
85A0
DIMM_A1 Uncorrectable ECC error encountered.
Pause
85A1
85A2
DIMM_A2 Uncorrectable ECC error encountered.
DIMM_A3 Uncorrectable ECC error encountered.
Pause
Pause
85A3
DIMM_A4 Uncorrectable ECC error encountered.
Pause
85A4
DIMM_B1 Uncorrectable ECC error encountered.
Pause
85A5
DIMM_B2 Uncorrectable ECC error encountered.
Pause
85A6
DIMM_B3 Uncorrectable ECC error encountered.
Pause
85A7
85A8
DIMM_B4 Uncorrectable ECC error encountered.
DIMM_C1 Uncorrectable ECC error encountered.
Pause
Pause
85A9
DIMM_C2 Uncorrectable ECC error encountered.
Pause
Revision 2.4
Intel order number E65697-010
Response
125
Appendix D: POST Code Errors
Intel® Server Board S3420GP TPS
Error Code
85AA
Error Message
DIMM_C3 Uncorrectable ECC error encountered.
Pause
Response
85AB
85AC
DIMM_C4 Uncorrectable ECC error encountered.
DIMM_D1 Uncorrectable ECC error encountered.
Pause
Pause
85AD
DIMM_D2 Uncorrectable ECC error encountered.
Pause
85AE
DIMM_D3 Uncorrectable ECC error encountered.
Pause
85AF
DIMM_D4 Uncorrectable ECC error encountered.
Pause
8601
8602
Override jumper is set to force boot from lower alternate BIOS bank of flash ROM
WatchDog timer expired (secondary BIOS may be bad!)
No Pause
No Pause
8603
Secondary BIOS checksum fail
No Pause
8604
Chipset Reclaim of non critical variables complete.
No Pause
9000
Unspecified processor component has encountered a non specific error.
Pause
9223
Keyboard component was not detected.
No Pause
9226
9243
Keyboard component encountered a controller error.
Mouse component was not detected.
No Pause
No Pause
9246
Mouse component encountered a controller error.
No Pause
9266
Local Console component encountered a controller error.
No Pause
9268
Local Console component encountered an output error.
No Pause
9269
9286
Local Console component encountered a resource conflict error.
Remote Console component encountered a controller error.
No Pause
No Pause
9287
Remote Console component encountered an input error.
No Pause
9288
Remote Console component encountered an output error.
No Pause
92A3
Serial port component was not detected
Pause
92A9
92C6
Serial port component encountered a resource conflict error
Serial Port controller error
Pause
No Pause
92C7
Serial Port component encountered an input error.
No Pause
92C8
Serial Port component encountered an output error.
No Pause
94C6
LPC component encountered a controller error.
No Pause
94C9
LPC component encountered a resource conflict error.
Pause
9506
95A6
ATA/ATPI component encountered a controller error.
PCI component encountered a controller error.
No Pause
No Pause
95A7
PCI component encountered a read error.
No Pause
95A8
PCI component encountered a write error.
No Pause
9609
Unspecified software component encountered a start error.
No Pause
9641
9667
PEI Core component encountered a load error.
PEI module component encountered an illegal software state error.
No Pause
Halt
9687
DXE core component encountered an illegal software state error.
Halt
96A7
DXE boot services driver component encountered an illegal software state error.
Halt
96AB
DXE boot services driver component encountered invalid configuration.
No Pause
96E7
0xA022
SMM driver component encountered an illegal software state error.
Processor component encountered a mismatch error.
Halt
Pause
0xA027
Processor component encountered a low voltage error.
No Pause
0xA028
Processor component encountered a high voltage error.
No Pause
0xA421
PCI component encountered a SERR error.
Halt
0xA500
ATA/ATPI ATA bus SMART not supported.
No Pause
0xA501
0xA5A0
ATA/ATPI ATA SMART is disabled.
PCI Express* component encountered a PERR error.
No Pause
No Pause
0xA5A1
PCI Express* component encountered a SERR error.
Halt
126
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS
Appendix D: POST Code Errors
Error Code
0xA5A4
PCI Express* IBIST error.
Error Message
Pause
Response
0xA6A0
DXE boot services driver Not enough memory available to shadow a legacy option ROM.
No Pause
POST Error Beep Codes
The following table lists POST error beep codes. Prior to system video initialization, the BIOS
uses these beep codes to inform users on error conditions. The beep code is followed by a
user-visible code on POST Progress LEDs.
Table 77. POST Error Beep Codes
Beeps
3
Error Message
Memory error
Revision 2.4
POST Progress Code
Multiple
Description
System halted because a fatal error related to the memory
was detected.
Intel order number E65697-010
127
Appendix E: Supported Intel® Server Chassis
Intel® Server Board S3420GP TPS
Appendix E: Supported Intel® Server Chassis
The Intel® Server Board S3420GP is supported in the following Intel server chassis. Please
refer to the latest Configuration Guide for detailed information at
http://www.intel.com/support/motherboards/server/s3420gp/sb/CS-030741.htm.
128

Intel® Server Chassis SR1630

Intel® Server Chassis SC5650UP

Intel® Server Chassis SC5299UP

Intel® Server Chassis SC5299BRP

Intel® Server Chassis SC5299DP
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS
Glossary
Glossary
This appendix contains important terms used in this document. For ease of use, numeric entries
are listed first (for example, “82460GX”) followed by alpha entries (for example, “AGP 4x”).
Acronyms are followed by non-acronyms.
Term
ACPI
Advanced Configuration and Power Interface
Definition
AP
Application Processor
APIC
ARP
Advanced Programmable Interrupt Control
Address Resolution Protocol
ASIC
Application Specific Integrated Circuit
ASMI
Advanced Server Management Interface
BIOS
Basic Input/Output System
BIST
Built-In Self Test
BMC
Bridge
Baseboard Management Controller
Circuitry connecting one computer bus to another, allowing an agent on one to access the other
BSP
Bootstrap Processor
Byte
8-bit quantity
CBC
Chassis Bridge Controller (A microcontroller connected to one or more other CBCs, together they
bridge the IPMB buses of multiple chassis.
CEK
CHAP
CMOS
Common Enabling Kit
Challenge Handshake Authentication Protocol
Complementary Metal-oxide-semiconductor
In terms of this specification, this describes the PC-AT compatible region of battery-backed 128 bytes
of memory, which normally resides on the server board.
DHCP
Dynamic Host Configuration Protocol
DPC
Direct Platform Control
EEPROM
Electrically Erasable Programmable Read-Only Memory
EHCI
Enhanced Host Controller Interface
EMP
EPS
Emergency Management Port
External Product Specification
ESB2
Enterprise South Bridge 2
FBD
Fully Buffered DIMM
F MB
Flexible Mother Board
FRB
FRU
Fault Resilient Booting
Field Replaceable Unit
FSB
Front Side Bus
GB
1024 MB
GPA
Guest Physical Address
GPIO
GTL
General Purpose I/O
Gunning Transceiver Logic
HPA
Host Physical Address
HSC
Hot-swap Controller
Hz
Hertz (1 cycle/second)
2
IC
Inter-Integrated Circuit Bus
IA
IBF
Intel Architecture
Input Buffer
Revision 2.4
®
Intel order number E65697-010
129
Glossary
Intel® Server Board S3420GP TPS
Term
Definition
ICH
I/O Controller Hub
ICMB
IERR
Intelligent Chassis Management Bus
Internal Error
IFB
I/O and Firmware Bridge
ILM
Independent Loading Mechanism
IMC
Integrated Memory Controller
INTR
I/OAT
Interrupt
I/O Acceleration Technology
IOH
I/O Hub
IP
Internet Protocol
IPMB
Intelligent Platform Management Bus
IPMI
Intelligent Platform Management Interface
IR
ITP
Infrared
In-Target Probe
KB
1024 bytes
KCS
Keyboard Controller Style
KVM
Keyboard, Video, Mouse
LAN
LCD
Local Area Network
Liquid Crystal Display
LDAP
Local Directory Authentication Protocol
LED
Light Emitting Diode
LPC
Low Pin Count
LUN
MAC
Logical Unit Number
Media Access Control
MB
1024 KB
MCH
Memory Controller Hub
MD2
Message Digest 2 – Hashing Algorithm
MD5
Message Digest 5 – Hashing Algorithm – Higher Security
ME
MMU
Management Engine
Memory Management Unit
ms
Milliseconds
MTTR
Memory Type Range Register
Mux
Multiplexor
NIC
NMI
Network Interface Controller
Nonmaskable Interrupt
OBF
Output Buffer
OEM
Original Equipment Manufacturer
Ohm
Unit of electrical resistance
OVP
PECI
Over-voltage Protection
Platform Environment Control Interface
PEF
Platform Event Filtering
PEP
Platform Event Paging
PIA
Platform Information Area (This feature configures the firmware for the platform hardware)
PLD
Programmable Logic Device
PMI
POST
Platform Management Interrupt
Power-On Self Test
PSMI
Power Supply Management Interface
130
Intel order number E65697-010
Revision 2.4
Intel® Server Board S3420GP TPS
Glossary
Term
PWM
Pulse-Width Modulation
Definition
QPI
RAM
QuickPath Interconnect
Random Access Memory
RASUM
Reliability, Availability, Serviceability, Usability, and Manageability
RISC
Reduced Instruction Set Computing
RMII
Reduced Media-Independent Interface
ROM
RTC
Read Only Memory
Real-Time Clock (Component of ICH peripheral chip on the server board)
SDR
Sensor Data Record
SECC
Single Edge Connector Cartridge
SEEPROM
Serial Electrically Erasable Programmable Read-Only Memory
SEL
System Event Log
SIO
SMBUS
Server Input/Output
System Management BUS
SMI
Server Management Interrupt (SMI is the highest priority non-maskable interrupt)
SMM
Server Management Mode
SMS
Server Management Software
SNMP
SPS
Simple Network Management Protocol
Server Platform Services
SSE2
Streaming SIMD Extensions 2
SSE3
Streaming SIMD Extensions 3
SSE4
Streaming SIMD Extensions 4
TBD
TDP
To Be Determined
Thermal Design Power
TIM
Thermal Interface Material
UART
Universal Asynchronous Receiver/Transmitter
UDP
User Datagram Protocol
UHCI
Universal Host Controller Interface
URS
UTC
Unified Retention System
Universal Time Coordinate
VID
Voltage Identification
VRD
Voltage Regulator Down
VT
Virtualization Technology
Word
WS-MAN
16-bit quantity
Web Services for Management
ZIF
Zero Insertion Force
Revision 2.4
Intel order number E65697-010
131
Reference Documents
Intel® Server Board S3420GP TPS
Reference Documents
Refer to the following documents for additional information:
132

Intel® Server Board S3420GP BIOS External Product Specification

Intel® Server Board S3420GP Common Core Integrated BMC External Product
Specification
Intel order number E65697-010
Revision 2.4
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Intel:
S3420GPLX BB3420GPLC BB3420GPV S3420GPV S3420GPLC BB3420GPLXSASM
Download PDF