mezzo48st - Pomerleau Gaz Propane

MEZZO48ST
Specifications
Please consult the manufacturer’s
installation manual for all details and
requirements before making a final
design layout decision.
MODEL
MEZZO48ST
HEIGHT
FRONT
WIDTH
FRONT
WIDTH
BACK WIDTH
MEZZO48ST
48" See-Through Direct Vent
Gas Fireplace
BACK
WIDTH
HEIGHT
DEPTH
DEPTH
VIEWING
AREA
GLASS SIZE
Actual
Actual
Framing
Framing
Actual
Actual
Framing
Framing
Actual
Actual
Framing
Framing
Actual
Actual
Framing
Framing
58
60-1/4
58
60-1/4
41-3/4
42
17-1/8
17
47-1/2 x 12-1/2
1/2" [13]
58" [1473]
18-1/8"
[460] 17-1/8"
[435]
8-9/16"
[217]
CENTERED ON APPLIANCE Ø 8" [203]
Top
62" [1575]
51-1/8" [1299]
62"
[1575]
41-3/4"
[1060]
23-3/4"
[603]
2-3/8"
[60]
2-3/4"
[70]
8-9/16"
[217]
42-1/2"
[1080]
15-5/8"
[397]
24-1/2"
[622]
4"
[102]
8-7/8"
[225]
7-1/4"
[184] GAS ACCESS
Left
Additional information can be found online at www.heatnglo.com
Front
ELECTRICAL ACCESS
8-9/16"
[217]
Right
Decorative Fronts Dimensions and Framing
MEZZO48ST
FRONT DIMENSIONS
51" [1295]
5/8" [16]
25"
[635]
13-1/8"
[333]
16-3/4"
[425]
24"
[610]
19"
[483]
13"
[330]
26-1/4"
[667]
5-7/8"
[149]
7-1/8"
[181]
48-3/4" [1238]
54-3/4" [1391]
49-3/16" [1249]
52-5/16" [1329]
Clean Face Trim
Loft Forge Front
21-3/8"
[543]
12-1/2"
[318]
27-1/4"
[692]
40-1/2" [1028]
48-9/16" [1234]
57-1/8" [1451]
Quattro Front
• Rectangular holes on bottom of access panel
should be covered.
• Rectangular holes on bottom of access panel must be exposed.
• Rectangular holes on bottom of access panel must be exposed.
• Approved for 0"-4" finishing material on inside fit method
• ONLY approved for 0"-1"
finishing material on overlap fit method
• ONLY approved for 0"-1"
finishing material on overlap fit method
• If finishing materials are 0-1”
thick, the outer trim ring
should be adjusted out so that the trim ring
overlaps the finishing material. This is intended to
provide the cleanest look.
• If finishing materials are 1-4”
thick, install the trim ring all the way in. Finishing materials may not extend
past the outside edge of
the trim ring.
FINISHED OPENING DIMENSIONS
51-1/8" [1299]
51-1/8" [1299]
15-3/4"
[400]
FIREPLACE VIEWING AREA
Inside Fit Method
(Clean Face Trim)
17-1/4"
[438]
FIREPLACE VIEWING AREA
Overlap Fit Method
(Loft Forge, Quattro)
Specifications
MEZZO48ST
Framing Dimension
Appliance Location
10"
[254]
48"
[1219]
48"
[1219]
1/2"
[13]
60-1/4" [1530]**
HEADER
DEPTH**
17-1/8"
[435]
HEADER
DEPTH**
Refer to Section 10 of install manual for hearth, mantel and wall
projection information.
If a HEAT-ZONE® or HEAT-DUCT will be installed, refer to section 5.E
of the installation manual for information.
1/2"
[13]
17"
[432]
1 HEAT-ZONE/HEAT-DUCT = Add 14" to ** dimension
2 HEAT-ZONE/HEAT-DUCTS = Add 28" to ** dimension
Wall Penetration
60-1/4"
[1530]
Do not pack with
insulation or
other material
* Adjust framing dimensions for interior sheathing (sheetrock)
** Header depth not to exceed 3-1/2”
*** If appliance is installed off of floor, maintain required clearances
to combustibles. Construct platform in accordance with local
building codes.
APPLIANCE MAY BE
INSTALLED OFF OF FLOOR***
Clearances to Combustibles
12"
10"
42"
[1067]
62"
[1570]
MEASUREMENT FROM TOP
OF FIREPLACE OPENING
TO CEILING
63"
[1600]
Minimal wall penetration
applies to both single-side and
see-through units. Single-side
shown.
31"
[787]
0
48"
[1219]
55-1/2"
[1410]
MANTEL PROJECTIONS - Combustible
TO CEILING
Note:
All measurements in inches.
0
31
MAX.
1
18
3
20
6
23
9
26
12
MANTEL leg/wall PROJECTIONS
29
Note: Clearance from
opening to
perpendicualar wall
MEASUREMENT FROM
TOP EDGE OPENING
Top View
Measurement from top edge opening
to bottom of appliance = 24-1/2"
4-1/2"
minimum
MANTEL PROJECTIONS - Non-Combustible
OVERLAP FIT
Note: All measurements in inches.
Combustible
16
16
7
31
5
4
18
3
7
UNLIMITED
FIREPLACE OPENING
See Appliance dimension diagram
in install manual - Dimension B
Acceptable on both sides of opening
Non-Combustible
31 MIN.
6
6
7"
minimum
3 ft. maximum
FIREPLACE OPENING
See Appliance dimension diagram
in install manual - Dimension B
MAX.
8
Top View
TO CEILING
MAX.
1
Note: Clearance from
opening to
perpendicualar wall
INSIDE FIT
Note: All measurements in inches.
TO CEILING
2
MEASUREMENT FROM
BOTTOM OF FIREPLACE
TO CEILING
1"
[25]
9
10
PRODUCT LISTING CODES
18
6
MIN.
5
11
11
4
0-9
10
MEASUREMENTS FROM TOP EDGE
OF THE APPLIANCE OPENING
Measurement from top edge of opening
to bottom of appliance = 24-1/2 IN.
US
ANSI Z21.88-2014
CAN
CSA 2.33-2014
UL307B
Product information provided is
not complete and is subject to
change without notice. Product
installation must adhere strictly
to instructions accompanying
product to avoid risk of fire and
potential injury.
MEASUREMENTS FROM TOP EDGE
OF THE APPLIANCE OPENING
Additional information can be found online at www.heatnglo.com
Measurement from top edge of opening
to bottom of appliance = 24-1/2 IN.
A brand of Hearth & Home Technologies®
Lakeville, MN
Web: heatnglo.com
Phone: 888-427-3973
952-985-6000
GM/HNG/MEZZO48ST_0615
Download PDF
Similar pages