Class I, Division 1, Groups A, B,C and D; Class II,
Division 1, Groups E, F and G; Class III, Division 1;
Class I, Division 2, Groups A, B, C and D.
NX-200/300
NEXEDGE® VHF/UHF Digital & Analog Portable Radios
GENERAL FEATURES
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
5 W (136-174, 400-470 MHz) Models
CSA Approval for 2 W Power Output
512 CH-GID / 128 Zones
64 CH-GID / 4 Zones (S Version)
12-Key Keypad Models*
14 Character Alphanumeric Aliases*
Backlit Dot Matrix LCD*
Function/Status LCD Icons*
Multi-Language Display*
Date & 12/24 Hour Time Clock*
Transmit/Busy/Call Alert/Warn LED
On/Off Volume Knob
16-Position Mechanical Selector
6 Front PF & Menu Keys*
2 Side PF Keys
500 mW Speaker Audio
Emergency Call Features
KMC-47GPS Speaker Mic Option
KPG-111D Windows® FPU
Flash Firmware Upgrading
MIL-STD-810 C/D/E/F/G
DIGITAL – TRUNKING MODE
GENERAL FEATURES Cont.
•
•
•
•
•
•
IP54/55 Water & Dust Intrusion
PC Serial Interface
SDM Manual Input1
Transparent Data Mode1
Intrinsically Safe Option*
VGS-1 Voice Guide/ Voice & GPS Data
Storage Option
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
NXDN® Digital Air Interface
AMBE+2™ VOCODER
6.25 & 12.5 kHz Channels
Over-the-Air Alias
Over-the-Air Programming
Paging Call
Emergency Call
All Group Call
Status Messaging1,2
Remote Stun/Kill1
Remote Check1
Short & Long Data Messages1
GPS Location with Voice1
NXDN® Scrambler Included
DES Encryption Module Option
AES & DES Encryption Module Option
AES/DES Software Key Loader Option
DIGITAL – GENERAL
DIGITAL – CONVENTIONAL MODE
•
•
•
•
•
64 Radio Access Numbers (RAN)
Individual & Group Selective Call3
Mixed FM/Digital Operation
Conventional IP Networks
Site Roaming
•
•
•
•
•
•
•
•
•
•
Individual Private Call
Group Call & Broadcast Call
Telephone Interconnect
Transmission Trunked Mode4
Message Trunked Mode4
Call Queuing with Priority4
Late Entry (UID & GID)4
4 Priority Monitor ID’s4
Remote Group Add1
Failsoft Mode
MULTI-SITE IP NETWORKS
COMPATIBLE
•
•
•
•
6,000 GIDs / UIDs
Wide Area Group Call
Auto Roaming Registration
Group Registration
SCAN
• Single Zone / Multi-Zone / List Scan
• Dual Priority Scan (Conventional)
FM MODE – GENERAL
•
•
•
•
25 & 12.5 kHz Channels
Conventional & LTR® Zones
FleetSync®/II, MDC-1200, DTMF3
QT / DQT & Two-Tone
(Conventional Zones Only)3
• Voice Inversion Scrambler
• Analog Scrambler Board Capability
FleetSync®/II (FM)
• PTT ID ANI / Caller ID3
• Selective / Group Call3
• Emergency Status / Text Messages1
MDC-1200
• PTT ID ANI / Caller ID3
• Emergency / Radio Check & Inhibit
* LCD features/operations not available
on NX-200S/300S
Three Models Available:
S Version: No LCD, No Front keys
14 Character LCD, 6 Front PF Keys
14 Character LCD, 6 Front PF Keys, 12-Key DTMF Keypad.
http://nexedge.kenwood.com
Options
■ KNB-47L
■ KSC-32
Li-Ion Battery
(1950mAh)
■ KEP-1*
Tri-Chemistry Rapid
Rate Charger
■ KNB-48L
■ KSC-326
Li-Ion Battery
(2550mAh)
■ KRA-25
Heavy Duty Earphone
VHF High Gain Antenna
■ KRA-22/23
Rapid Rate Six Unit Charger
for Ni-Cd/Ni-MH/Li-ion
■ KRA-28
VHF/UHF Helical Antenna
VHF Broad
Band Antenna
■ KMC-41M*
■ KNB-50NC**
Ni-MH Battery
(2000mAh) Intrinsically Safe
MIL-STD & IP 54/55
Speaker Microphone
KNB-48L
■ VGS-1
■ KRA-26/27
■ KMC-47GPS
■ KNB-61LC*
Voice Guide
& Storage Unit
VHF/UHF Whip Antenna
GPS Speaker
Microphone
Li-Ion Battery
(1880mAh) CSA
■ KBH-11
■ KRA-16/17
■ KHS-11*
■ KBP-7
Belt Clip (2.5")
VHF/UHF Stubby Antenna
Heavy Duty Earphone
Alkaline Battery Case
All accessories and options may not be available in all markets.
Contact an authorized Kenwood dealer for details and complete list of all accessories and options.
*CSA Radio Class I, Division 1, Groups A&B Certification. **CSA Radio Class I, Division 2, Groups A and B Certification.
Main Specifications
NX-200
NX-200S
NX-300
NX-300S
All Models
RECEIVER
GENERAL
Frequency Range
Type 1
Type 2
Number of Channels
Zones
Max. Channels per Zone
Channel Spacing
Analog
Digital
Operating Voltage
Battery Life
5-5-90
(with KNB-48L)
10-10-80
Operating Temperature Range CSA Approval
Frequency Stability
Antenna Impedance
Dimensions (W x H x D) Projections not included
Radio only
with KNB-47L
with KNB-48L
Weight (net)
Radio only
with KNB-47L
with KNB-48L
IC Certification
Type 1
Type 2
Sensitivity
136-174 MHz 136-174 MHz
400-470 MHz
400-470 MHz
512
64
512
64
128
4
128
4
250
16
250
16
12.5 / 15 / 25 / 30 kHz
12.5 / 25 kHz
6.25 / 12.5 kHz
7.5V DC ± 20%
Approx. 14.5 hours
Approx. 9.0 hours
-22˚ F to +140˚ F (-30˚ C to +60˚ C)
± 2.0 ppm
± 1.0 ppm
50 Ω
Selectivity
Intermodulation
Distortion
Spurious Response
Audio Distortion
Audio Output
Analog
Analog
0.20 µV
0.25 µV
0.25 µV
72 dB
65 dB
70 dB (±50,100 kHz)
70 dB
Less than 3%
500 mW / 8 Ω
TRANSMITTER
RF Power Output / CSA Approved RF Power Output
Spurious Response
FM Hum & Noise
Analog @ 25 kHz
Analog @ 12.5 kHz
Audio Distortion
Modulation
2.28 x 5.02 x 1.63 in (58 x 127.5 x 41.3 mm)
2.28 x 5.02 x 1.63 in (58 x 127.5 x 41.3 mm)
2.28 x 5.02 x 1.91 in (58 x 127.5 x 48.5 mm)
8.82 oz (250 g)
13.23 oz (375 g)
14.29 oz (405 g)
282D-378400
282D-378500
282D-378501
5 W / 1 W / 2 W CSA
70 dB
45 dB
40 dB
Less than 3%
16K0F3E, 11K0F3E, 8K30F1E,
8K30F1D, 8K30F7W, 4K00F1E,
4K00F1D, 4K00F7W, 4K00F2D
Analog measurements made per TIA/EIA 603 and specifications shown are typical.
Specifications are subject to change without notice, due to advancements in technology.
CSA IS approved by CSA as intrinsically safe for use in Classes I, II & III, Div. 1, Groups C, D, E, F, G and are also approved for non-Incendive
use in Class I, Div. 2, Groups A,B, C, D hazardous locations (Exception: KMC-47GPS is approved for Class I Div. 1 GP CD & N.I. Class I Div. 2
GP CD). Using an Intrinsically Safe battery on a radio does not constitute an Intrinsically Safe (I.S.) radio. All Kenwood I.S. radios must be
certified at Kenwood by inspection, logging & proper labeling. The appropriate I.S. labor code must be specified on all I.S. radio orders and the
proper model I.S. battery must be used with the radio. Kenwood I.S. batteries can be purchased separately for existing Kenwood certified I.S.
radios. Intentionally or inadvertently representing a Kenwood radio as I.S. without proper Kenwood certification can result in serious safety
and/or legal liability issues for your company. Please contact your local dealer for details.
Applicable MIL-STD & IP
Digital @ 6.25kHz (3% BER)
Digital @ 12.5kHz (3% BER)
Analog (12 dB SINAD)
Analog @ 25 kHz
Analog @ 12.5 kHz
FleetSync® is a registered trademark of JVC KENWOOD Corporation. Footnotes from front:
1
LTR® is a registered trademark of Transcrypt International.
Requires compatible PC software
application or console.
AMBE+2TM is a trademark of Digital Voice Systems Inc.
2
S Version- pre-programmed key operation.
Windows® is a registered trademark of Microsoft Corporation.
3
S Version- LCD dependent and some
NXDN® is a registered trademark of JVC KENWOOD Corporation
key-based functions not available.
and Icom Inc.
NEXEDGE® is a registered trademark of JVC KENWOOD Corporation. 4 These trunked features are primarily
CSA® is a registered trademark of the Canadian Standards Association. system programming and operational
dependent. Priority Monitor also requires
NX subscriber settings.
MIL Standard
MIL 810C
Methods/Procedures
MIL 810D
Methods/Procedures
MIL 810E
Methods/Procedures
MIL 810F
Methods/Procedures
MIL 810G
Methods/Procedures
Low Pressure
High Temperature
Low Temperature
Temperature Shock
Solar Radiation
Rain
Humidity
Salt Fog
Dust
Vibration
Shock
500.1/Procedure I
501.1/Procedure I, II
502.1/Procedure I
503.1/Procedure I
505.1/Procedure I
506.1/Procedure I, II
507.1/Procedure I, II
509.1/Procedure I
510.1/Procedure I
514.2/Procedure VIII, X
516.2/Procedure I, II, V
500.2/Procedure I, II
501.2/Procedure I, II
502.2/Procedure I, II
503.2/Procedure I
505.2/Procedure I
506.2/Procedure I, II
507.2/Procedure II, III
509.2/Procedure I
510.2/Procedure I
514.3/Procedure I
516.3/Procedure I, IV
500.3/Procedure I, II
501.3/Procedure I, II
502.3/Procedure I, II
503.3/Procedure I
505.3/Procedure I
506.3/Procedure I, II
507.3/Procedure II, III
509.3/Procedure I
510.3/Procedure I
514.4/Procedure I
516.4/Procedure I, IV
500.4/Procedure I, II
501.4/Procedure I, II
502.4/Procedure I, II
503.4/Procedure I, II
505.4/Procedure I
506.4/Procedure I, III
507.4
509.4
510.4/Procedure I, III
514.5/Procedure I
516.5/Procedure I, IV
500.5/Procedure I, II
501.5/Procedure I, II
502.5/Procedure I, II
503.5/Procedure I
505.5/Procedure I
506.5/Procedure I, III
507.5/Procedure II
509.5
510.5/Procedure I
514.6/Procedure I
516.6/Procedure I, IV
International Protection Standard
Dust & Water Protection
IP54/55
ADS#05012 Printed in CANADA