Presented By
Dallas
Ft Worth
Austin
Houston
NicolScales.com
800.225.8181
Contact Us
Nicol Scales & Measurement is an ISO Accredited Calibration
Company that has provided calibration, repair and sales of all types
of weighing and measurement products since 1931.
C054-E072A
Advanced Performance UniBloc Balances
AP Series
( 7 :LYPLZ
(K]HUJLK7LYMVYTHUJL<UP)SVJ)HSHUJLZ
Faster Response and Higher Stability
/PNO:WLLK
Fast weighing response
:[YLZZ-YLL
Reliable weighing results
,MMPJPLUJ`KYP]LU*VU]LUPLUJLZ
Va r i o u s p r o d u c t i v i t y - b o o s t i n g w e i g h i n g a p p l i c a t i o n s
* Al l mode l s : U S B-B t y p e c o n n e c t o r a s s t a n d a rd
A P W: U S B- A t yp e an d B t yp e as st an d ard
* A P 2 2 4 W w ith o p tio n a l io n i zer
/PNO:WLLK
Fast weighing response
F a ste st R e sp o n se in Its C la ss * w ith UniBloc AP Tec hnology
Shimadzu analytical balances boast a one-piece UniBloc weighing sensor, which is now
even more advanced. The improved UniBloc sensor offers up from 7 seconds (previous
model) to 1.5 seconds faster response.
* Compared to previous Shimadzu models
Response Time Comparison
AP324W
Indication [g]
0.0120
Previous model
0.0100
0.0080
0.0060
0.0040
0.0020
0.0000
0
1
2
3
4
5
6
7
New AP324W approx. 1.5 seconds
8
9
10
Time [sec]
Previous model approx. 7 seconds
Model
AP324W
AU (previous model)
0.1 mg
1.5 sec (central value)
7 sec (central value)
New Weighing Sensor: UniBloc AP
Using the new UniBloc AP weighing sensor significantly improves core
performance (compared to previous Shimadzu models). This allows more
accurate measurements with less stress on the operator.
A d v a n c e d Dig ital C o n tro l fo r Fast, Reliable Weighing
The improved measuring feel provides for more comfortable use.
AP-i System (intelligent - Advanced Processing System)
Digital control
Detects variations in weight
High-speed control!
Calculates weight signal!
Smoothing
Weight signal + Noise +
External disturbances
Cuts noise and
external disturbances!
Weight signal
Measuring feel has been significantly improved by using the advanced digital control technology and smoothing technology.
AP-i system provides reliable weighing even in an challenging environment and enables high-speed weighing of small samples.
4
:[YLZZ-YLL
Reliable weighing results
B u ilt-in H ig h -P e rformanc e Ionizer
( O p ti o n a l )
A new ionizer is able to remove static electricity in about 1/10
the time of previous ionizers
This unit allows acquisition of reliable weighing results by eliminating static
electricity that can affect measurements without scattering powder.
Note: Example of typical static electricity removal time (±1000 V ĺ ±100 V):
1 sec for STABLO-AP and 10 sec for STABLO-EX
AC Method with Excellent Ion Polarity Balance
Mount the STABLO-AP in the balance and use it as a built-in model
Comparison of Static Removal Rates (Typical Examples)
STABLO-AP
STABLO-EX (FAN ON)
Previous model
1000
Static Charge Voltage (V)
900
800
10 times
Quicker
700
600
500
400
300
Quicker!
200
100
0
0
2
4
6
8
10
12
14
16
18
20
Static Removal Time (sec)
Measurement Conditions
• Time from ±1000 V to ±100 V
• 150 × 150 mm CPM (20 pF) used
• Distance between CPM and ionizer: 100 mm
AP Series
Advanced Performance UniBloc Balances
5
,MMPJPLUJ`KYP]LU*VU]LUPLUJLZ
Va r i o u s p r o d u c t i v i t y - b o o s t i n g w e i g h i n g a p p l i c a t i o n s
U S B O ff e r s G reater Exp an d ab i l i ty
(USB host: APW only)
Equipped standard with an RS-232C connector, a USB device and a USB host. You can now
simultaneously send output to both a computer and printer or connect a USB flash drive, a
barcode reader, or an external numeric keypad.
USB and RS-232C
are standard
USB host is available
for APW
USB flash drive
Connecting a USB memory device allows you to record large amounts of weighing data in CSV format. Used in
combination with the interval output function, it also enables recording of long-term changes over time.
Example of a record:
File name
Date and time
Weighing value
Display capture function
Weighing display can be recorded into USB memory in BMP format. User name,
date/time, setting can be done with display information.
Numeric keypad
Connecting a common external numeric keypad makes it easier to enter numeric values. This is especially
useful for entering the mass value of weights, setting upper/lower limit values for the comparator function, or
entering the sample count during piece counting mode.
Barcode reader
A barcode reader can be connected. Simply reading a barcode makes it possible to input user ID/Password. It is
possible to manage sample IDs using barcodes.
An example of login by barcode
User001
User ID card
Can login as User001
LOGIN 01
01
User002
User ID card
LOGIN 02
USB Connect
User003
User ID card
LOGIN 03
An ID and password are need to login to the AP series if protected access is activated. With the barcode, an operator can login by scanning the
barcode instead of inputting an ID and password.
* The latest information can be seen from the Shimadzu website (http://www.shimadzu.com/an/balance/)
6
E a sy - t o - R e a d O rg an i c EL D i sp l ay
(All models)
Because the pixel elements in the organic electroluminescence display emit light, the screen can be seen clearly even in dark locations.
Multi-language display capability* provides a more intuitive operating interface. A wider viewing angle has also improved the visibility of
measurement values, which helps increase the efficiency of measuring operations.
Clearly visible from the side
English example
Exceptional Visibility
The visibility remains the same even when viewed from different angles. The viewing angle is a wide expanse of ±85 degrees, both vertically and
horizontally. That means the display is clearly visible even when working beside the balance. A high-resolution dot-matrix display makes it easy to
read even detailed text.
* Japanese, English and Chinese
P e r i o d i c I n s p ecti on Su p p o rt Fun c t ion
AP series supports periodic inspections. The
Example of printing
(APW/APX only)
Printing sample
function allows inspection of repeatability, corner
load error, and linearity by simply following
instructions displayed on the screen.
Select the inspection mode.
IL: Loaded weight
I0: Zero value
In this case, repeatability inspection is selected.
Place standard weights as instructed.
Results are displayed.
AP Series
Advanced Performance UniBloc Balances
7
- V Y < Z L Y Z V M / 7 3 * : ` Z [ L T Z (7>VUS`
B u ff e r S o l u t i o n Preparati on Mo de
(APW only)
•Recipes for 13 commonly used buffer solutions are included as standard
Preparation recipes for commonly used buffer solutions are provided as standard.
e.g. disodium phosphate, sodium acid citrate
•Instructions are shown on the display
The target weighing value is shown on the display and analog bar in order to compare the target with the current weight. Manual calculation is
not needed.
•Record function
Record output with date, time and operator name.
pH level of mobile phase (eluent) solutions used in liquid chromatographs is adjusted to improve separation of components and extend the life of
columns. This pH adjustment process is performed using a buffer solution. Currently, the most common method is using a pH meter to measure
the pH as the solution is prepared; however, this process requires considerable time and effort, which can cause operational bottlenecks.
An alternative method is available that does not require a pH meter. It involves preparing solutions by weighing fixed theoretically calculated
quantities of an acid and base.
AP series supports weighing these acids and bases. If the type and quantity of the buffer solution is specified, the balance displays the type and
quantity of sample that should be weighed. Then the buffer solution can be prepared easily by adding water to the specified quantity of sample
weighed accordingly.
Example of preparation by AP series
Buffer solution preparation list
Number
Select the buffer solution mode.
Specify the type and quantity.
Displays the name and quantity of sample.
1
100mM
phosphoric acid (sodium)
pH = 2.1
2
10mM
phosphoric acid (sodium)
pH = 2.6
3
50mM
phosphoric acid (sodium)
pH = 2.8
4
100mM
phosphoric acid (sodium)
pH = 6.8
5
10mM
phosphoric acid (sodium)
pH = 6.9
6
20mM
citric acid (sodium)
pH = 3.1
7
20mM
citric acid (sodium)
pH = 4.6
8
10mM
tartaric acid (sodium)
pH = 2.9
9
10mM
tartaric acid (sodium)
pH = 4.2
10
20mM
acetic acid (ethanolamine)
pH = 9.6
11
100mM
acetic acid (sodium)
pH = 4.7
12
100mM
boric acid (potassium)
pH = 9.1
13
100mM
boric acid (sodium)
pH = 9.1
Prepare as instructed on screen.
Complete buffer
solution
8
* Results can be printed with date/time and user ID.
S a m p l e P re parati on
(APW only)
Typically, preparation of a standard sample solution requires tedious calculations.
AP series simplifies the process with automated calculations.
Example of preparation by AP series
Weigh 25 mg Amitriptyline to make standard solution
Standard sample of Amitriptyline is Amitriptyline Hydrochloride .
Standard solution of Amitriptyline
Calculation is essential to determine part of Acidum hydrochloricum by molecular weight to make 100
mg/mL Amitriptyline solution.
Amitriptyline
100 mg
Molecular weight of Amitriptyline: 277.4
1 mL
Molecular weight of Acidum hydrochloricum: 36.5
Molecular weight of Amitriptyline Hydrochloride: 277.4 + 36.5 = 313.9
Amitriptyline Hydrochloride
To compare the molecular weight of Amitriptyline Hydrochloride with Amitriptyline, the following
calculation is necessary.
Amitriptyline Acidum hydrochloricum
Molecular weightt
Molecular weight
277.4
36.5
313.9/277.4 = 1.132
The molecular weight of Amitriptyline Hydrochloride is 1.132 times of Amitriptyline.
So, if 25mg of Amitriptyline is used, it follows that the weight of Amitriptyline Hydrochloride should be:
25 mg × 1.132 = 28.3 mg.
Hence, 28.3 mg of Amitriptyline Hydrochloride is needed to make the correct standard solution.
No need for manual calculation
AP series can automatically calculate the sampling weight using the molecular amount of the standard sample, molecular
weight of unnecessary sample, and the target value in order to reach the correct concentration solution.
Just weigh the target weight value on display and the target weight of the standard sample can be obtained.
Target weighing value
Current sample value
"OK" mark shown when target weight is reached.
Standard sample value
Checking weighing conditions on the same display
AP Series
Advanced Performance UniBloc Balances
9
-\UJ[PVUZ9LJVTTLUKLK
MVY[OL7OHYTHJL\[PJHS0UK\Z[Y`
H i g h - S e c u r ity U ser Manag ement
(All models)
Operations can be kept secure with user ID and password protection. Access rights can be
specified separately for each user to prohibit unauthorized actions such as performing
calibration or changing the settings. User IDs can also be used for barcode management.
User Selection Screen
Password Inputting Screen
P r i n t i n g D a t a i n A cco rd ance w i t h Var ious Regulat ions
Functionality for customizing the content of printed information supports
compliance with various ISO, GLP, GMP, and other requirements.
(All models)
An example of printing
Title of result
Manufacturer name
<Printed content>
Model name
• Date
Serial number
• Time
Date
• User name
Time
• Balance manufacturer name
User name
• User ID
Standard weight value
• Serial number
Weighing value
before calibration
• Balance ID
Weighing value
after calibration
• Software version
• Minimum sample quantity
Signature
Example of selecting printed content
M i n i m u m S ampl e Q u an ti ty (War ning F unc t ion)
(All models)
Reproducibility can be confirmed by repeatedly measuring weights as instructed by AP
series. The minimum sample quantity is automatically determined from the standard
deviation and recorded in AP series.
If the minimum sample quantity requirement is not satisfied during measurement, an
indicator flashes to warn the user.
R e c i p e F u n c ti on
Sample recipes can be registered, allowing users to simply follow instructions on display.
10
Minimum sample quantity
(AP-W only)
:\WWVY[PUN4VYL,MMPJPLU[3HIVYH[VY`>VYRHUK
7 Y V ] P K P U N / P N O L Y 9 L S P H I P S P [ `
Weighing results and analysis results can be stored in a database. Reports can be generated according to results in a prescribed format.
Analytical Balance
UHPLC
AP series
Nexera X2
Weighing results by Balance
Analysis results by LC
Database
Analysis results by LC
LabSolutions software can store
analysis results and weighing results
in a database at the same time.
Weighing results by Balance
* When you use the LabSolutions software,
you need the Balance Agent at the same
time. If you have any questions about
details, please feel like to contact us.
Report example
Analysis results by LC
Weighing results
The report can be generated
automatically according to results.
AP Series
Advanced Performance UniBloc Balances
11
>PKL=HYPL[`VM-\UJ[PVUZ[V:\WWVY[<ZLYZ
Sm a r t S e t t i n g s
(All models)
Response and stability settings can be changed during measurements with a single touch. Changing the settings for different applications can make
it even easier to use.
The indicator is operated using the left and right arrow keys. Moving the setting toward [R] prioritizes response, which
makes it easier to operate the balance. Conversely, moving it toward [S] makes it easier to stabilize weight values,
which can improve readability in environments with vibration.
Patented
User-friendly arrow keys
Moving it left prioritizes response and moving it right prioritizes stability. Five setting levels are available.
S p e c i fi c G r avi ty Measu rement
(All models)
In combination with an optional specific gravity measurement kit, the balance can be used to measure specific gravity.
By using sinkers, the specific gravity of liquid can be measured as well. This allows measurement of the specific gravity of metals, rubbers,
plastics, and other materials easily.
First measure the empty weight.
Then place it in the container
The specific gravity value is displayed using simple steps.
filled with water, as instructed on the screen.
P S C a n d Cl ock-C A L
(APW/APX only)
A Perfect Self Calibration (PSC) function is included. The analytical balance automatically
Room temperature change
detects any temperature changes that could affect sensitivity and automatically starts
calibration.
The Clock-CAL function enables automatic calibration at a pre-specified time (for example,
Permissible
sensitivity error
before starting work, during lunch, or after work hours).
PSC (Perfect Self Calibration)
Room
temp.
Sensitivity
error
Automatically calibrate sensitivity at times
specified by the Clock-CAL function.
0
8:00 a.m.
12:30 p.m.
Clock-CAL
O t h e r F u n c ti on s
Piece counting, statistical calculation, mol unit measurement and pass/fail decisions
12
5:00 p.m.
9LJVTTLUKLKM\UJ[PVUZVM(7ZLYPLZMVYLHJOPUK\Z[Y`
Various user support functions are available in AP series.
AP series provides solutions for each industry as follows.
Chemical
Faster response time provides stress-free measurement.
And, AP series has functions to support sample preparation for various analytical techniques, especially for
Liquid Chromatography. In addition, the Aluminum body has higher chemical resistance.
Built-in
Ionizer
Pharmaceutical
Buffer
solution
preparation
Sample
preparation
Barcode
reader
function
Printing
format
customize
USB
accessories
Periodic
inspection
support
Minimum
sample
quantity
Buffer
solution
preparation
Sample
preparation
Barcode
reader
function
Printing
format
customize
USB
accessories
Periodic
inspection
support
Buffer
solution
preparation
Sample
preparation
Barcode
reader
function
Car manufacturers focus on accuracy management.
The periodic inspection function supports management in this area.
Specific gravity measurement of metal samples can be accomplished easily. This function supports quality
control for materials.
Printing
format
customize
University
Periodic
inspection
support
Increasing attention is placed on food safety and traceability globally. Higher accuracy of weighing can play a
part. PSC (Perfect Self Calibration) starts calibration automatically by temperature changes. The Clock-CAL
function can be used to have the balance automatically calibrated at the preset time.
The ionizer can remove static without scattering sample.
Built-in
Ionizer
Car, Heavy industry
USB
accessories
AP series provides a high level of measurement reliability to meet the strictest of customer requirements.
Moreover, the customizable printing format function for ISO/GLP/GMP, minimum sample quantity function and
security function support compliance with industry regulations.
Built-in
Ionizer
Food
Printing
format
customize
USB
memory
Periodic
inspection
support
Barcode
reader
function
Weighing balances are necessary tools in academic institutions, where durability is a prized quality. AP series
offers excellent durability and stability for long-term use.
Built-in
Ionizer
Printing
format
customize
USB
memory
Buffer
solution
preparation
Sample
preparation
* Ionizer, printer and specific gravity kit are optional items.
AP Series
Advanced Performance UniBloc Balances
13
AP Series Sp ecificatio ns
W Series Analytical Balances
Series
W Series
Model
Capacity
Minimum Display
Calibration Weight
External Calibration Weight Range for Span
Calibration
Repeatability (Standard deviation)
Minimum Weight*1
Linearity
Response Time*2
Operating Temperature/Humidity Range
Sensitivity Stability Against Temperature Range
Pan Size
Body Dimensions
Weight
Display
Input/Output Terminal
AP124W
AP224W
AP324W
120 g
220 g
0.1 mg
Built-in
95 to 220.009 g
(200 g)
320 g
45 to 120.009 g
(100 g)
0.1 mg
95 to 320.009 g
(300 g)
0.15 mg
200 mg
±0.3 mg
±0.2 mg
Approx. 2 sec.
5 to 40°C 20 to 85% *3
±2 ppm/°C (10 to 30°C)
ø91 mm
Approx. W 212 × D 367 × H 345 mm
Approx. 7.0 kg
OEL display (dot matrix)
RS-232C (D-sub9P plug) USB host (Type A) USB device (Type B)
Ionizer
X Series / Y Series Analytical Balances
Series
Model
Capacity
Minimum Display
Calibration Weight
External Calibration Weight Range for Span
Calibration
Repeatability (Standard deviation)
Minimum Weight*1
Linearity
Response Time*2
Operating Temperature/Humidity Range
Sensitivity Stability Against Temperature Range
Pan Size
Body Dimensions
Weight
Display
Input/Output Terminal
X Series
AP224X
AP324X
AP124Y
AP224Y
AP324Y
120 g
220 g
320 g
120 g
220 g
320 g
0.1 mg
Built-in
45 to 120.009 g
95 to 220.009 g
(100 g)
(200 g)
0.1 mg
No
95 to 320.009 g
45 to 120.009 g
95 to 220.009 g
95 to 320.009 g
(300 g)
(100 g)
(200 g)
(300 g)
0.15 mg
0.1 mg
0.15 mg
200 mg
±0.2 mg
±0.3 mg
±0.2 mg
±0.3 mg
Approx. 2 sec.
5 to 40°C 20 to 85% *3
±2 ppm/°C (10 to 30°C)
ø91 mm
Approx. W 212 × D 367 × H 345 mm
Approx. 7.0 kg
Approx. 6.5 kg
OEL display (dot matrix)
RS-232C (D-sub9P plug) USB device (Type B) Ionizer
RS-232C (D-sub9P plug) USB device (Type B)
*1 According to USP Chapter 41. This is the tested value by the weight of the balance’s capacity of 5%.
*2 The response time value is typical.
*3 Non-condensing.
14
Y Series
AP124X
A P Series
AP124W
AP224W
AP324W
AP124X
AP224X
AP324X
AP124Y
AP224Y
AP324Y
EP-100 Electronic Printer
EP-110 Electronic Printer
STABLO-AP Ionizer
SMK-601 Specific Gravity Measurement Kit
Options
Description
EP-100 Electronic Printer
EP-110 Electronic Printer
LABEL ROLL PAPER, CEF45-S (10 sets)
Display protective cover (set of 5)
RS-232C Cable (1.5 m)
AC adapter (standard accessory)
Internal windbreak plate
AP Series
Advanced Performance UniBloc Balances
15
AP Series
E x t e r n a l Di men si on s o f A P Seri es
(AP124W, AP224W, AP324W, AP124X, AP224X, AP324X) Weight: Approx. 7.0 kg
(AP124Y, AP224Y, AP324Y) Weight: Approx. 6.5 kg
243
180
139
156
421
ø91
170
166
213
6.5
98
344.5
220.5
432.8
367
140.5
90.5
87.5
259
HOOK FOR UNDER PAN
E x t e r n a l Di men si on s o f STA B LO -AP
Static Electricity Remover
POWER
2-Way Ionizer Designed Specifically
for Electronic Balances
87
START/STOP
RUN
ALARM
POWER
RUN
70±3
124
ALARM
49
10±2
110±3
35
164
147
130
4
147.7
90
Ion Generation Method
AC corona discharge method
Ion Balance
±10 V
Effective Static Removal Range
Approx. 50 mm to 400 mm from the outlet
Static Elimination Time (approx.)
1 second (Typical value) (from ±1000 V to ±100 V)
Ozone Concentration
0.06 ppm
Electrode Probes
Tungsten (durability: 30,000 hours)
Weight
Approx. 710 g (Main unit: 395 g, Stand: 315 g)
Operating Temperature and Humidity
0 ºC to +40 ºC, 25 % RH to 85 % RH (non-condensing)
Rated Electric Power Supply
DC 24 V, 1.0 A
For Research Use Only. Not for use in diagnostic procedures.
This publication may contain references to products that are not available in your country. Please contact us to check the availability of these
products in your country.
Company names, products/service names and logos used in this publication are trademarks and trade names of Shimadzu Corporation, its
subsidiaries or its affiliates, whether or not they are used with trademark symbol “TM” or “®”.
Third-party trademarks and trade names may be used in this publication to refer to either the entities or their products/services, whether or not
they are used with trademark symbol “TM” or “®”.
Shimadzu disclaims any proprietary interest in trademarks and trade names other than its own.
www.shimadzu.com/an/
The contents of this publication are provided to you “as is” without warranty of any kind, and are subject to change without notice. Shimadzu
does not assume any responsibility or liability for any damage, whether direct or indirect, relating to the use of this publication.
© Shimadzu Corporation, 2016
First Edition: August 2016, Printed in Japan 3655-09610-50ANS