SV-XFP-ZXD8DT - Starview International

SV-XFP-ZXD8DT
Tunable XFP
Multi-rate 9.95Gbps to 11.3Gbps, supporting OC-192/ STM-64/
10G LAN/ 10G FC and OC192 Tunable C-Band DWDM 50GHz
spacing with DDM c/w wavelength locker, up to 80km
Features
• Supports 8.5Gb/s to 11.35Gb/s
• -300 to +1600 ps/nm Dispersion Tolerance
• Supports 50GHz ITU-based channel spacing
(C-Band) with a wavelength locker
• Monolithic MZM Tunable TOSA
• Temperature range: -5°C to 70°C
• RoHS-6 Compliant (lead-free)
• Power dissipation <3.5W
• Built-in digital diagnostic functions
• High performance APD Receiver
• Adjustable receiver threshold with option for
automatic optimization through FEC feedback
Applications
• DWDM 10Gb/s SONET/SDH
• DWDM 10Gb/s Ethernet & 10Gb/s
Fibre Channel
• DWDM 10Gb/s SONET/SDH w/FEC
• DWDM 10Gb/s Ethernet and 10Gb/s
Fibre Channel w/FEC
Absolute Maximum Ratings
Parameter
Symbol
Min
Max
Unit
Maximum Supply Voltage #1
Vcc3
-0.5
4.0
V
Maximum Supply Voltage #2
Vcc2
-0.5
6.0
V
Storage Temperature
TS
-40
85
ºC
Case Operating Temperature
TOP
-5
70
ºC
PRdmg
+3
Receiver Damage Threshold
dBm
Electrical Characteristics (TOP = -5 to 70 °C, VCC5 = 4.75 to 5.25 Volts)
Parameter
Symbol
Min
Supply Voltage #1
Vcc3
Supply Voltage #2
Vcc5
Supply Current – Vcc5 supply
Supply Current – Vcc3 supply
Temperature
Module total power dissipation
Typ
Max
Unit
Ref.
3.13
3.46
V
4.75
5.25
V
Icc5
500
mA
Icc3
750
mA
P
3.5
W
1
Ω
2
Transmitter
Input differential impedance
Rin
100
Differential data input swing
Vin,pp
120
820
mV
Transmit Disable Voltage
VD
2.0
Vcc
V
Transmit Enable Voltage
VEN
GND
GND+
08
V
850
mV
4
Receiver
Differential data output swing
Vout,pp
500
3
Data output rise time
tr
35
ps
5
Data output fall time
tf
35
ps
5
VccHOST
V
6
LOS Fault
1
VLOS fault
Vcc – 0.5
www.starviewint.com
SV-XFP-ZXD8DT
Tunable XFP
Multi-rate 9.95Gbps to 11.3Gbps, supporting OC-192/ STM-64/
10G LAN/ 10G FC and OC192 Tunable C-Band DWDM 50GHz
spacing with DDM c/w wavelength locker, up to 80km
LOS Normal
VLOS norm
Power Supply Rejection
GND
PSR
GND+0.5
V
6
See Note 7 below
7
Reference Clock (AC-Coupled)
Single-ended peak to
voltage
swing
Single-ended resistance
peak
Frequency clock tolerance
VSEPP
200
RL
40
Δf
-100
+100
ppm
40
60
%
Duty cycle
900
50
mV
60
Notes:
1. Maximum total power value is specified across the full temperature and voltage range.
2. After internal AC coupling.
3. Or open circuit.
4. Into 100 ohms differential termination.
5. 20 – 80 %
6. Loss Of Signal is open collector to be pulled up with a 4.7k – 10kohm resistor to 3.15 – 3.6V. Logic 0
indicates normal operation; logic 1 indicates no signal detected.
7. Per Section 2.7.1. in the XFP MSA Specification1.
Optical Characteristics (EOL, TOP = -5 to 70°C, VCC5 = 4.75 to 5.25 Volts)
Transmitter
Parameter
Symbol
Min
POUT
-1
Optical Extinction Ratio
ER
10
Wavelength range (ITU Grid)
Λ
1528.77
1563.86
nm
40
60
%
Output Opt. Pwr: 9/125 SMF
Crossing Ratio
Center Wavelength Spacing
Transmitter Center Wavelength –
End Of Life
Side Mode Suppression Ratio
Typ
Max
Unit
+3.0
dBm
11
dB
50
Λc
λc -2.5
SMSR
35
λc
λc +2.5
GHz
1
GHz
2
dB
Wavelength tuning (Cold Start)
Wavelength tuning (Warm)
Ref.
0.5
30
s
2
s
Tx Jitter (SONET) 20kHz80MHz
Txj1
0.3
UI
3
Tx Jitter (SONET) 4MHz – 80MHz
Txj2
0.1
UI
4
Relative Intensity Noise
RIN
-135
dB/Hz
SBS threshold (1% of launch power
reflected) – Dither On
+16
dBm
Receiver
Overload
PMAX
-6
Optical Center Wavelength
λC
1270
Receiver Reflectance
LOS De-Assert
2
dBm
1615
nm
Rrx
-27
dB
LOSD
-30
dBm
www.starviewint.com
SV-XFP-ZXD8DT
Tunable XFP
Multi-rate 9.95Gbps to 11.3Gbps, supporting OC-192/ STM-64/
10G LAN/ 10G FC and OC192 Tunable C-Band DWDM 50GHz
spacing with DDM c/w wavelength locker, up to 80km
LOS Assert
LOSA
LOS Hysteresis
-37
dBm
0.5
dB
Notes:
1. Corresponds to approximately 0.4 nm.
2. λc = Specified ITU Grid wavelength. Wavelength stability is achieved within 30 seconds of power up.
3. Measured with a host jitter of 50 mUI peak-to-peak.
4. Measured with a host jitter of 7 mUI RMS.
DWDM Wavelength Guide
ITU Channel
ITU Channel
Frequency (THz) Center Wavelength(nm)
Frequency (THz) Center Wavelength(nm)
Product Code
Product Code
17
191.7
1563.86
40
194.0
1545.32
18
191.8
1563.05
41
194.1
1544.53
19
191.9
1562.23
42
194.2
1543.73
20
192.0
1561.42
43
194.3
1542.94
21
192.1
1560.61
44
194.4
1542.14
22
192.2
1559.79
45
194.5
1541.35
23
192.3
1558.98
46
194.6
1540.56
24
192.4
1558.17
47
194.7
1539.77
25
192.5
1557.36
48
194.8
1538.98
26
192.6
1556.55
49
194.9
1538.19
27
192.7
1555.75
50
195.0
1537.40
28
192.8
1554.94
51
195.1
1536.61
29
192.9
1554.13
52
195.2
1535.82
30
193.0
1553.33
53
195.3
1535.04
31
193.1
1552.52
54
195.4
1534.25
32
193.2
1551.72
55
195.5
1533.47
33
193.3
1550.92
56
195.6
1532.68
34
193.4
1550.12
57
195.7
1531.90
35
193.5
1549.32
58
195.8
1531.12
36
193.6
1548.51
59
195.9
1530.33
37
193.7
1547.72
60
196.0
1529.55
38
193.8
1546.92
61
196.1
1528.77
39
193.9
1546.12
Ordering Information
Part number
SV-XFPZXD8DT
3
Description
TX Power
(dBm)
RX Sens.
(dBm)
Distance
(km)
DDM
Starview XFP module Multi-rate 9.95Gbps
to 11.3Gbps supporting OC-192/ STM-64/
10G LAN/ 10G FC and OC192 Tunable CBand DWDM 50GHz spacing with Digital
Diagnostic Monitoring (DDM) c/w
wavelength locker, distance up to 80km
Fiber
Budget
(dB)
-1 to 3
-27 to -6
26
80
YES
www.starviewint.com
Download PDF
Similar pages