Gemini GV6K and Gemini GT6K Programmer'

www.comoso.com
p/n 88-019934-01 A
Automation
Gemini GV6K and
Gemini GT6K
Programmer's Guide
Effective: October 1, 2001
www.comoso.com
User Information
WARNING
!
!
Gem6K Series products are used to control electrical and mechanical
components of motion control systems. You should test your motion
system for safety under all potential conditions. Failure to do so can result
in damage to equipment and/or serious injury to personnel.
Gem6K Series products and the information in this user guide are the proprietary property of Parker Hannifin Corporation or its licensers, and
may not be copied, disclosed, or used for any purpose not expressly authorized by the owner thereof.
Since Parker Hannifin constantly strives to improve all of its products, we reserve the right to change this user guide and software and
hardware mentioned therein at any time without notice.
In no event will the provider of the equipment be liable for any incidental, consequential, or special damages of any kind or nature
whatsoever, including but not limited to lost profits arising from or in any way connected with the use of the equipment or this user guide.
© 2001, Parker Hannifin Corporation
All Rights Reserved
Motion Planner and Servo Tuner are trademarks of Parker Hannifin Corporation.
Microsoft and MS-DOS are registered trademarks, and Windows, Visual Basic, and Visual C++ are trademarks of Microsoft Corporation.
Technical Assistance
Contact your local automation technology center (ATC) or distributor, or ...
North America and Asia:
Europe (non-German speaking):
Germany, A ustria, Switzerland:
Compumotor Division of Parker Hannifin
5500 Business Park Drive
Rohnert Park, CA 94928
Telephone: (800) 358-9070 or (707) 584-7558
Fax: (707) 584-3793
FaxBack: (800) 936-6939 or (707) 586-8586
e-mail: tech_help@cmotor.com
Internet: http://www.compumotor.com
Parker Digiplan
21 Balena Close
Poole, Dorset
England BH17 7DX
Telephone: +44 (0)1202 69 9000
Fax: +44 (0)1202 69 5750
HAUSER Elektronik GmbH
Postfach: 77607-1720
Robert-Bosch-Str. 22
D-77656 Offenburg
Telephone: +49 (0)781 509-0
Fax: +49 (0)781 509-176
Tech nical
Automation
Su pport
E-mail: Tech_Help@cmotor.com
www.comoso.com
CONTENTS
OVERVIEW.................................................................. I
About This Manual ...................................................... i
Organization of This Manual................................... i
Programming Examples..........................................ii
Reference Documentation.......................................ii
Assumptions of Technical Experience....................ii
Before You Begin ......................................................iii
Install and Use Motion Planner .............................iii
Technical Support......................................................iii
PROGRAMMING FUNDAMENTALS ..................... 1
Motion Planner Programming Environment............... 2
Wizard-Based Programming................................... 2
Native Code Programming ..................................... 3
Command Syntax........................................................ 4
Introduction ............................................................ 4
Description of Syntax Letters and Symbols............ 5
General Guidelines for Syntax................................ 6
Command Value Substitutions ............................... 7
Assignment and Comparison Operators ................. 7
Programmable Inputs and Outputs Bit Patterns...... 9
Creating Programs .................................................... 10
Program Example ................................................. 10
Storing Programs ...................................................... 11
Memory Allocation............................................... 11
Checking Memory Status...................................... 12
Executing Programs (options) .................................. 13
Creating and Executing a Set-up Program................ 13
Program Security ...................................................... 14
Controlling Execution of Programs and the Command
Buffer........................................................................ 14
COMEXC (Continuous Command Execution)..... 14
COMEXL (Save Command Buffer on Limit) ...... 15
COMEXR (Effect of Pause/Continue Input) ........ 15
COMEXS (Save Command Buffer on Stop) ........ 16
Restricted Commands During Motion ...................... 17
Variables................................................................... 18
Converting Between Binary and Numeric Variables
.............................................................................. 18
Using Numeric (VAR and VARI) Variables.......... 19
Using Binary Variables......................................... 22
Unconditional Looping and Branching................. 23
Conditional Looping and Branching..................... 25
Program Interrupts (ON Conditions) ........................ 29
Error Handling .......................................................... 30
Enabling Error Checking ...................................... 31
Defining the Error Program .................................. 31
Canceling the Branch to the Error Program.......... 32
Error Program Set-up Example............................. 34
Non-Volatile Memory .............................................. 35
System Performance..................................................35
COMMUNICATION..................................................37
Communication Options ...........................................38
Motion Planner Communication Features.................38
Ethernet Networking .................................................39
Overview...............................................................39
Networking Guidelines .........................................42
Configuring the Gem6K for Ethernet
Communication .....................................................43
Networking with Other 6K or Gem6K Products
(Peer-to-Peer) ........................................................46
Networking with OPTO22 SNAP I/O...................48
Networking with a DVT Vision System ...............50
Networking with an Allen-Bradley SLC 5/05 PLC
...............................................................................51
Error Conditions....................................................54
Serial Communication...............................................56
Controlling Multiple Serial Ports ..........................56
RS-232C Daisy-Chaining......................................57
Daisy-Chaining and RP240s .................................60
RS-485 Multi-Drop ...............................................60
BASIC OPERATION SETUP....................................63
Before You Begin .....................................................64
Setup Parameters Discussed in this Chapter .........64
Using a Setup Program..........................................65
Resetting the Controller ........................................65
Memory Allocation ...................................................65
Drive Setup ...............................................................66
Drive Stall Detection (stepper only)......................66
Drive Resolution (stepper only) ............................66
Disable Drive On Kill (servo only) .......................66
Scaling.......................................................................67
Units of Measure without Scaling .........................67
What is Scaling?....................................................67
When Should I Define Scaling Factors? ...............67
Acceleration & Deceleration Scaling (SCLA).......68
Velocity Scaling (SCLV)......Error! Bookmark not
defined.
Distance Scaling (SCLD and SCLMAS)......... Error!
Bookmark not defined.
Positioning Modes.....................................................71
Preset Positioning Mode........................................72
Continuous Positioning Mode...............................73
End-of-Travel Limits ................................................77
Homing (Using the Home Inputs) .............................79
Encoder-Based Stepper Operation (stepper only) .....84
Encoder Resolution ...............................................84
Stall Detection & Kill-on-Stall..............................84
Encoder Set Up Example ......................................84
www.comoso.com
Encoder Count/Capture Referencing .................... 85
Tuning Procedures (servos only) .............................. 85
Entering Load Settings ......................................... 85
Position Mode Tuning .............................................. 85
Position Mode Tuning Procedure ......................... 86
Filter Adjustments .................................................... 87
Target Zone Mode (move completion criteria for
servos only)............................................................... 89
Programmable Inputs and Outputs (onboard and
external inputs & outputs) ........................................ 90
Programmable I/O Bit Patterns............................. 91
Input Functions ..................................................... 94
Output Functions ................................................ 105
Variable Arrays (teaching variable data)................ 110
Basics of Teach-Data Applications..................... 110
Summary of Related Gem6K Series Commands 112
Teach-Data Application Example....................... 112
PRODUCT CONTROL OPTIONS ........................ 115
Safety Features ....................................................... 116
Options Overview................................................... 116
Stand-Alone Interface Options ........................... 116
Programmable Logic Controller ......................... 117
Host Computer Interface .................................... 117
Custom Graphical User Interfaces (GUIs).......... 117
Programmable I/O Devices..................................... 118
Programmable I/O Functions.............................. 118
Thumbwheels ..................................................... 119
PLCs ................................................................... 119
PLC Scan Mode.................................................. 120
RP240 Remote Operator Panel............................... 123
Configuration...................................................... 123
Operator Interface Features ................................ 124
Using the Default Menus .................................... 125
Joystick Control, Analog Inputs ............................. 130
Joystick Control.................................................. 130
Analog Input Interface......... Error! Bookmark not
defined.
Host Computer Interface ........................................ 133
Graphical User Interface (GUI) Development Tools
................................................................................ 134
CUSTOM PROFILING ........................................... 135
S-Curve Profiling.................................................... 136
S-Curve Programming Requirements................. 136
Determining the S-Curve Characteristics ........... 136
Programming Example ....................................... 137
Calculating Jerk .....Error! Bookmark not defined.
Compiled Motion Profiling..................................... 139
Compiled Following Profiles.............................. 142
Dwells and Direction Changes ........................... 144
Compiled Motion Versus On-The-Fly Motion ... 145
Related Commands............................................. 146
Compiled Motion — Sample Application 1 ....... 147
Compiled Motion — Sample Application 2 ....... 148
Compiled Motion — Sample Application 3 ....... 151
Compiled Motion — Sample Application 4 ....... 152
On-the-Fly Motion (pre-emptive GOs).................... 155
OTF Error Conditions......................................... 156
On-The-Fly Motion — Sample Application....... 157
Registration .............................................................159
How to Set up a Registration Move ....................159
Registration Move Accuracy (see also Registration
Move Status below).............................................159
Preventing Unwanted Registration Moves
(methods).............................................................160
Registration Move Status & Error Handling.......160
Registration — Sample Application 1 ................161
Registration — Sample Application 2 .......... Error!
Bookmark not defined.
Registration — Sample Application 3 ................163
Synchronizing Motion (GOWHEN and TRGFN
operations)...............................................................163
Conditional “GO”s (GOWHEN)............................163
Trigger Functions (TRGFN) ................................166
FOLLOWING ...........................................................167
Ratio Following – Introduction...............................168
What can be a master? ........................................168
Following Status (TFSF, TFS & FS Commands)
............................................................................169
Implementing Ratio Following ...............................170
Ratio Following Setup Parameters......................170
Follower vs. Master Move Profiles .....................175
Performing Phase Shifts......................................178
Geared Advance Following.................................180
Summary of Ratio Following Commands...........181
Master Cycle Concept.............................................182
Master Cycle Commands ....................................182
Summary of Master Cycle and Wait Commands 185
Technical Considerations for Following .................186
Performance Considerations ...............................186
Master Position Prediction ..................................187
Master Position Filtering.....................................187
Following Error...................................................188
Maximum Velocity and Acceleration (Stepper
Axes Only) ..........................................................189
Factors Affecting Following Accuracy ...............189
Preset vs. Continuous Following Moves.............191
Master and Follower Distance Calculations........192
Using Other Features with Following .................194
Troubleshooting for Following (see also Chapter 8)
................................................................................196
Error Messages....................................................197
Following Commands .............................................198
MULTI-TASKING ...................................................201
Introduction to Multi-Tasking.................................202
Using Multi-Tasking to Run Programs ...............202
Interaction Between Tasks ..................................206
Tasks ...................................................................208
How a “Kill” Works While Multi-Tasking .........209
Using Gem6K Resources While Multi-Tasking .....210
Associating Axes with Tasks ..............................210
Sharing Common Resources Between Multiple
Tasks ...................................................................211
Locking Resources to a Specific Task ................211
How Multi-tasking and the % Prefix Affect
Commands and Responses..................................211
Input and Output Functions and Multi-tasking ...213
www.comoso.com
Multi-Tasking Performance Issues ......................... 214
When is a Task Active? ...................................... 214
Task Swapping.................................................... 214
Task Execution Speed......................................... 215
TROUBLESHOOTING ........................................... 217
Troubleshooting Basics........................................... 218
Solutions to Common Problems ............................. 218
Program Debug Tools............................................. 221
Status Commands ............................................... 222
Error Messages ................................................... 229
Trace Mode......................................................... 232
Single-Step Mode ............................................... 234
Break Points........................................................ 235
Simulating I/O Activation................................... 235
Simulating Analog Input Channel Voltages ....... 237
Motion Planner’s Panel Gallery.......................... 237
Technical Support................................................... 238
Operating System Upgrades ................................... 238
Product Return Procedure....................................... 238
INDEX ....................................................................... 239
www.comoso.com
www.comoso.com
OVERVIEW
About This Manual
This manual is designed to help you implement the Gem6K Series Product’s features in your
application. Detailed feature descriptions are provided, including application scenarios and
programming examples. For details on each Gem6K command, refer to the Gem6K Series
Command Reference.
Organization of This Manual
Chapter
Information
Chapter 1.
Programming Fundamentals
Discussion of essential programming guidelines and standard
programming features such as branching, variables, interrupts, error
handling, etc.
Chapter 2.
Communication
Communication considerations, such as using Motion Planner, alert
event handling, communication server and fast status control, RS-232
daisy-chains and RS-485 multi-drops, etc.
Chapter 3.
Basic Operation Setup
General operation setup conditions, such as number of axes, scaling
factors, feedback device setup, programmable input and output
functions, end-of-travel limits, homing, etc.
Chapter 4.
Product Control Options
Considerations for implementing various product control methods,
such as programmable I/O, a joystick, an RP240, custom GUI, etc.
Chapter 5.
Custom Profiling
Descriptions of custom profiling features such as S-Curves, timed
data streaming, compiled profiles, on-the-fly motion profiling,
registration, and synchronized motion.
Chapter 6.
Following
Feature descriptions and application examples for using Following
features.
Chapter 7.
Multi-Tasking
Feature descriptions and application examples for using multi-tasking
in your application.
Chapter 8.
Troubleshooting
Methods for isolating and resolving hardware and software problems.
www.comoso.com
Programming Examples
Programming examples are provided in this document to demonstrate how the Gem6K
product's features may be implemented. These examples are somewhat generalized, due to
the diverse nature of the family of Gem6K Series products and their application;
consequently, some attributes, such as the I/O bit pattern referenced, may differ from those
available with your particular Gem6K product.
Reference Documentation
This document is intended to accompany the printed and online documents listed below, as
part of the Gem6K product user documentation set.
Reference Document
INTERNET ACCESS:
These documents are
also available to view
and print from our web
site (www.compumotor.com).
Description
Gem6K Series Hardware Installation Guide
Hardware-related information specific to the Gem6K
Series product:
• Product hardware specifications
• Installation instructions
• Troubleshooting procedures
• Servo tuning instructions
Gem6K Series Command Reference
Detailed descriptions of all Gem6K Series Programming
Language commands. Quick-reference tables are also
provided.
EVM32 Installation Guide
Specifications and installation instructions for the EVM32
expansion I/O.
COM6SRVR Communications
The COM6SRVR is a 32-bit OLE automation server for adding
Gem6K communication capability to your custom applications
created with programming languages such as Visual Basic or
Visual C++. This companion document includes descriptions
of all methods and properties, and programming examples.
Motion Planner Online Help
Online instructional aids such as:
• Tutorials
• Introduction and tutorial for programming with Wizards
• Context-sensitive help for Wizard-based programming
• Documentation of programmer’s guide
• Step-by-step programming coaches
• Conceptual overviews
• Advanced programming details
• Sample programs
• Documentation of the Gem6K Series command
language,
including all command descriptions and the contents of
the manual you are currently reading
• Documentation of the Communications Server OLE
automation server (facilitates communications between
Gem6K and your custom Windows software)
Assumptions of Technical Experience
To effectively use the information in this manual, you should have a fundamental
understanding of the following:
•
•
•
•
•
ii
Electronics concepts, such as voltage, switches, current, etc.
Motion control concepts such as motion profiles, torque, velocity, distance, force, etc.
Programming skills in a high-level language such as C, C++, or BASIC is helpful
Ethernet communication protocol (if using the Ethernet port)
If you are new to the Gem6K Series Programming Language, we encourage you to
use the Motion Planner Wizards Editor (version 4.2 or later for Gem6K support).
Gem6K Series Programmer’s Guide
www.comoso.com
Before You Begin
Before you begin to implement the Gem6K controller’s features in your application you
should complete all the installation and test procedures provided in your Gem6K Series
Hardware Installation Guide.
Install and Use Motion Planner
Motion Planner is a Windows-based graphical interface that assists you with programming
and tuning your Gem6K Series controller, as well as setting up your Compumotor drives. The
Motion Planner CD-ROM is provided in your ship kit. The Motion Planner interface allows
you to:
• Create, edit, download, and upload programs.
• Tune your servo system.
• Test & debug programs and controller operation.
Additional details are provided on page 2 and in the Motion Planner Help System.
Technical Support
For solutions to your questions about implementing Gem6K product software features, first
look in this manual. Other aspects of the product (command descriptions, hardware specs, I/O
connections, graphical user interfaces, etc.) are discussed in the respective manuals or Online
Help systems listed above in Reference Documentation (see page ii).
If you cannot find the answer in this documentation, contact your local Automation
Technology Center (ATC) or distributor for assistance.
If you need to talk to our in-house application engineers, please contact us at the numbers
listed on the inside cover of this manual. (The phone numbers are also provided when you
issue the HELP command to the Gem6K controller.) NOTE: The BBS contains the latest
software upgrades and late-breaking product documentation.
FAX number for technical support;
bulletin board service,#see BBS;
software, update from BBS;
BBS;
Email support: tech_help@cmotor.com
Overview
iii
www.comoso.com
www.comoso.com
Programming Fundamentals
1
CHAPTER ONE
Programming
Fundamentals
IN THIS CHAPTER
This chapter is a guide to general Gem6K programming tasks. It is divided into these main topics:
•
•
•
•
•
•
•
•
Motion Planner programming environment ......................... 2
Command syntax.................................................................. 4
Creating programs ................................................................ 10
Storing programs.................................................................. 10
Executing programs ............................................................. 13
Creating and executing a set-up program ............................. 13
Program Security.................................................................. 14
Controlling execution – programs & command buffer......... 14
•
•
•
•
•
•
•
Restricted commands during motion ............................ 17
Using Variables ............................................................ 18
Program flow control.................................................... 23
Program interrupts ........................................................ 29
Error handling............................................................... 30
Non-volatile memory.................................................... 35
System performance considerations.............................. 35
www.comoso.com
Motion Planner Programming Environment
Every Gem6K Series controller is shipped with Motion Planner, a free Windows-based
programming tool designed to simplify your programming efforts. The Motion Planner CDROM is provided in your ship kit. Updates may be downloaded, free of charge, from the
compumotor.com web site.
Motion Planner supports two programming paradigms: Wizard-based programming, and Native
Code programming (working directly with the Gem6K programming language).
Wizard-Based Programming
Motion Planner includes the Wizard Editor, which is intended to be your primary program
development environment for the Gem6K. (version 4.2 or later)
The Wizard Editor makes programming easy, eliminates the need to learn the programming
language and frees you from concerning yourself with syntax errors.
• A Start Wizard guides you through creating your program structure and configuring your
Gem6K (drives, feedback, I/O, servo tuning, etc.).
• Additional wizards guide you through all other programming tasks, such as creating
motion profiles, I/O handling, error handling, program logic and branching, adding subprograms, etc.
NOTE: All programming features that can be implemented with native code (in a textbased Program Editor) can also be accomplished in the Wizard Editor.
• The Tag Name Dictionary allows you to label variables, axes, and I/O so that you can
program in terms that are relevant to your machine.
• If you have existing programs in an Editor, you can easily include them into the Wizard
editor (using the Native Code wizard), so you don’t have to rewrite your code.
• The Wizard Editor also includes interactive debug tools (break points, trace mode) and a
status window to help you test and debug your application.
• Context-sensitive help is always available – just click the Help button or press the F1 key.
How to get started:
1. Install Motion Planner.
2. Launch Motion Planner and select your Gem6K product. Motion Planner opens a new
Wizard Editor file.
3. When prompted to see an introduction and tutorial, click Yes. This will help you
understand the basic features of the Wizard Editor and the programming process.
2
Gem6K Series Programmer’s Guide
www.comoso.com
Native Code Programming
As an alternative to using the Wizard Editor, you may program directly with the Gem6K
Command Language (“Native Code”). Motion Planner has several tools to help you:
ACCESSING THE TOOLS: These tools are exposed when you first launch Motion
Planner.
• Program Editor: This is your primary interface for programming with the Gem6K
Command Language.
• Terminal Emulator: This is your primary communications interface to send commands
directly to the Gem6K.
• Servo Tuner: This graphical tuning utility helps you visually tune your servo axes. Then
you can copy the resulting gains into your program in the Program Editor. NOTE: Before
attempting motion, be sure to tune your axes. Tuning guidelines are provide on page
• Motion Panel: This feature allows definition of quick command buttons and other useful
debugging and functional tools to assist in programming your Gem6K.
• Online Help: While you are programming in Motion Planner’s Editor, Terminal or Servo
Tuner, you have immediate access to all command descriptions (the contents of the
Gem6K Series Command Reference, as well as the contents to this Programmer’s Guide).
To access the command descriptions, click on the Help menu and select Contents; from
there you can browse the “Gem6K Command Language” or you can search for the
command or a topic in the Index tab.
The rest of the contents in this manual are directed toward the native code programmer. If you
are new to the Gem6K Series Programming Language, be sure to read Chapter 1 (Programming
Fundamentals) thoroughly. Then proceed to the relevant chapters for the features you need for
your programs.
NOTE: If you later decide to use the Wizards Editor, you can copy code from the Program
Editor and paste it into Native Code objects in the Wizard program tree.
TIP: For complex programming tasks, like setup programming, error programming, Following
profile development, etc., you can use the relevant wizard in the Wizards Editor, then copy the
generated code from the Code Viewer and paste it into a Program Editor file.
Chapter 1. Programming Fundamentals
3
www.comoso.com
Command Syntax
Introduction
The Gem6K programming language accommodates a wide range of needs by providing basic
motion control building blocks, as well as sophisticated motion and program flow constructs.
The language comprises simple ASCII mnemonic commands, with each command separated
by a command delimiter (carriage return, colon, or line feed). The command delimiter signals
the Gem6K product that a command is ready for processing.
Upon receiving a command followed by a command delimiter, the Gem6K controller places
the command in its internal command buffer, or queue. Here the command is executed in the
order in which it is received. To make the command execute immediately, place an
exclamation point (!) in front of it (e.g., The TAS command will be executed after all
commands ahead of it in the command buffer are executed; but !TAS will execute before any
other commands in the command buffer).
Spaces and tabs within a command are processed as neutral characters. Comments can be
specified with the semicolon (;) character — all characters following the semicolon and
before the command delimiter are considered program comments.
Some commands contain one or more data fields in which you enter numeric or binary values
or text:
Sample program, as viewed in an editor:
; *********************************************************
; This is a program that executes a trapezoidal motion
; profile on axes 1 and 2
; *********************************************************
DEL motion
; (a precaution) Delete program called
"motion"
DEF motion
; Begin definition of program called "motion"
DRIVE1
; Enable drive
MC0
; Set position mode to preset
A20
; Set accel to 20 units/sec/sec
V8
; Set velocity to 8 units/sec
D100000
; Set distance to 100,000 counts
; Execute motion on axes 1 and 2
END
; End definition of program called "motion"
• Numeric data fields. For example, A20,10 is an acceleration (A) command that sets the
acceleration to 20 units/sec2.
• Binary fields. For example, DRIVE1 is a drive enable (DRIVE) command that enables
the drive.
• Text fields. For example, STARTPpowrup is a startup program assignment (STARTP)
command that assigns the program called “powrup” as the startup program to be
executed automatically when the Gem6K product is power up or reset.
• To check what the data field settings are for a particular command, simply type in the
command without the data fields. The Gem6K will display the command settings. For
example, after executing the A20, noted above, you could type in the A command by
itself and the Gem6K controller would respond with A20.
Some commands contain no data fields:
• Status Commands. For example, TASF responds by displaying a list of status conditions
for each axis.
• Reset
These are command line comments, comprising a semi-colon and text.
The comments are separated from the command by a tab.
A carriage return is placed at the end of each command line.
DEL motion
Text field
Command name
DRIVE 1
Binary data field
; *********************************************************
; This is a program that executes a trapezoidal motion
; profile on axes 1 and 2
; *********************************************************
DEL motion
; (a precaution) Delete program called "motion"
DEF motion
; Begin definition of program called "motion"
DRIVE1
; Enable drives
MC0
; Set position mode to preset
A20
; Set accel to 20 units/sec/sec
V8
; Set velocity to 8 units/sec
D100000
; Set distance to 100,000 counts
GO
; Execute motion
END
; End definition of program called "motion"
Command name
4
Gem6K Series Programmer’s Guide
www.comoso.com
Description of Syntax Letters and Symbols
The command descriptions provided within the Gem6K Series Command Reference use alphabetic letters and ASCII
symbols within the S y n t a x description to represent different parameter requirements (see INEN example below).
INEN
Letter/Symbol
Input Enable
Type
Syntax
Units
Range
Default
Response
Inputs; Program Debug Tools
<!><B>INEN<d><d><d>...<d>
d = Ø, 1, E, or X
Ø = off, 1 = on, E = enable, X = don't change
E
INEN:
*INENEEEE_EEEE_EEEE_EEEE_E
See Also
[ IN ], INFNC, INLVL, INPLC, INSTW, TIN, TIO
Product
Rev
Gem6K
5.0
Description
a .......... Represents an axis specifier.
B .......... Represents the number of the product's I/O brick. External I/O bricks are represented by numbers 1 through n (to connect
external I/O bricks, refer to your product's Installation Guide). On-board I/O are address at brick location zero (Ø). If the
brick identifier is omitted from the command, the controller assumes the command is supposed to affect the onboard I/O.
b *......... Represents the values 1, 0, X or x; does not require field separator between values.
c .......... Represents a character (A to Z, or a to z)
d .......... Represents the values 1, 0, X or x, E or e ; does not require field separator between values. E or e enables a specific
command field. X or x leaves the specific command field unchanged or ignored. In the ANIEN command, the “d” symbol
may also represent a real numeric value.
i .......... Represents a numeric value that cannot contain a decimal point (integer values only). The numeric range varies by
command. Field separator required.
r .......... Represents a numeric value that may contain a decimal point, but is not required to have a decimal point. The numeric
range varies by command. Field separator required.
t .......... Represents a string of alpha numeric characters from 1 to 6 characters in length. The string must start with a alpha
character.
! .......... Represents an immediate command. Changes a buffered command to an immediate command. Immediate commands
are processed immediately, even before previously entered buffered commands.
% .......... (Multitasking Only) Represents a task identifier. To address the command to a specific task, prefix the command with “i%”,
where “i” is the task number. For example, the 4%CUT command uses task #4 to execute the program called “CUT”.
, .......... (comma) Represents a field separator. Commands with the symbol r or i in their Syntax description require field
separators. Commands with the symbol b or d in their Syntax description do not require field separators (but they may be
included). See General Guidelines table below.
@ .......... Represents a global specifier, where only one field need be entered. Applicable to all commands with multiple command
fields.
< > ...... Indicates that the item contained within the < > is optional, not required by that command.
NOTE: Do not confuse with <cr>, <sp>, and <lf>, which refer to the ASCII characters corresponding to a carriage
return, space, and line feed, respectively.
[ ] ...... Indicates that the command between the [ ] must be used in conjunction with another command, and cannot be used
by itself.
* The ASCII character b can also be used within a command to precede a binary number. When the b is used in this context, it is not to be
replaced with a 0, 1, X, or x. Examples are assignments such as VARB1=b10001, and comparisons such as IF(3IN=b1001X1).
Order of Precedence for Command Prefix Characters (from left to right):
<!><%><@><a><B>
st
1 : Immediate
nd
2 : Task number
rd
3 : Apply to all axes or I/O bricks
rd
3 : Axis number
rd
3 : I/O brick number
Chapter 1. Programming Fundamentals
5
www.comoso.com
General Guidelines for Syntax
Guideline Topic
Guideline
Examples
Neutral Characters
• Space (<sp>)
• Tab (<tab>)
Using neutral characters anywhere within a
command will not affect the command.
Set velocity to 10 rps:
V<sp>10 <cr>
(In the examples on the right, a space is
represented by <sp>, a tab is <tab>), and a
carriage return is <cr>)
Add a comment to the command:
V 10 <tab> ;set velocity <cr>
Command Delimiters:
• Carriage rtn (<cr>)
• Line feed (<lf>)
• Colon (:)
All commands must be separated by a
Set acceleration to 10 rev/sec/sec:
A 10<cr>
command delimiter. A carriage return is the
A 10<lf>
most commonly used delimiter. To use a line
A 10: V 25: D 25000: GO<cr>
in a live terminal emulator session, press
ctrl/J. The colon (:) delimiter allows you to
place multiple commands on one line of code,
but only if you add it in the program editor (not
during a live terminal emulator session).
Case Sensitivity
There is no case sensitivity. Use upper or
lower case letters within commands.
Initiate motion
GO
go
Comment Delimiter (;)
All text between a comment delimiter and a
command delimiter is considered program
comments.
Add a comment to the command:
V10<tab> ;set velocity
Field Separator (,)
Commands with the symbol r or i in their
Syntax description require field separators.
INSGLP EXAMPLE
Global Command
Identifier (@)
When you wish to set the command value
equal on all axes, add the @ symbol at the
beginning of the command (enter only the
value for one command field).
Check the status of all digital outputs (onboard, and
on external I/O bricks):
@OUT
Bit Select Operator (.)
The bit select operator allows you to affect
Enable error-checking bit #9:
one or more binary bits without having to enter ERROR.9-1
all the preceding bits in the command.
Enable error-check bits #9-12:
Syntax for setup commands:
ERROR.9-1,1,1,1
[command name].[bit #]-[binary value]
Syntax for conditional expressions:
[command name].[bit #]=[binary value]
IF statement based on value of axis status bit #12:
IF(AS.12=b1)
Left-to-right Math
All mathematical operations assume
left-to-right precedence.
Binary and hexadecimal
values
When making assignments with or
Binary: IF(IN=b1x01)
comparisons against binary or hexadecimal
values, you must precede the binary value
Hexadecimal: IF(IN=h7F)
with the letter “b” or “B”, and the hex value
with “h” or “H”. In the binary syntax, an “x”
simply means the status of that bit is ignored.
Multi-tasking Task
Identifier (%)
Use the % command prefix to identify the
command with a specific task.
VAR1=5+3*2
Result: Variable 1 is assigned the value of
16 (8*2), not 11 (5+6).
Launch the “move1” program in Task 1:
1%move1
Check the error status for Task 3:
3%TER
Check the system status for Task 3:
3%TSS
NOTE: The command line is limited to 100 characters (excluding spaces).
6
Gem6K Series Programmer’s Guide
www.comoso.com
Command Value Substitutions
Many commands can substitute one or more of its command field values with one of these
substitution items (demonstrated in the programming example below):
VAR..........Places current value of the numeric variable in the corresponding command field.
VARB .......Uses the value of the binary variable to establish all the command fields.
VARI .......Places current value of the integer variable in the corresponding command field.
READ .......Information is requested at the time the command is executed.
DREAD .....Reads the RP240's numeric keypad into the corresponding command field.
DREADF...Reads the RP240's function keypad into the corresponding command field.
TW ............Places the current value set on the thumbwheels in the corresponding command field.
DAT..........Places the current value of the data program (DATP) in the corresponding command field.
Programming Example: (NOTE: The substitution item must be enclosed in parentheses.)
VAR1=15
A5,(VAR1),4,4
VARB1=b1101XX1
GO(VARB1)
; Set variable 1 to 15
; Set acceleration to 5,15,4,4 for axes 1-4, respectively
; Set binary variable 1 to 1101XX1 (bits 5 & 6 not affected)
; Initiate motion on axes 1, 2 & 4 (value of binary
; variable 1 makes it equivalent to the GO1101 command)
OUT(VARB1)
; Turn on outputs 1, 2, 4, and 7
VARS1="Enter Velocity" ; Set string variable 1 to the message "Enter Velocity"
V2,(READ1)
; Set the velocity to 2 on axis 1. Read in the velocity for
; axis 2, output variable string 1 as the prompting message
;
1. Operator sees "ENTER VELOCITY" displayed on the screen.
;
2. Operator enters velocity prefixed by !' (e.g., !'20).
HOMV2,1,(TW1)
; Set homing velocity to 2 and 1 on axes 1 and 2, respectively.
; Read in the home velocity for axis 3 from thumbwheel set 1
HOMV2,1,(DAT1)
; Set homing velocity to 2 and 1 on axes 1 and 2, respectively.
; Read home velocity for axis 3 from data program 1.
VARI1=2*3
; Set integer variable 1 to 6 (2 multiplied by 3)
D(VARI2),,(VARI3) ; Set the distance of axis 1 equal to the value of
; integer variable 2, and the distance of axis 3 equal to
; the value of integer variable 3.
RULE OF THUMB
Not all of the commands allow command field substitutions. In general, commands with a
binary command field (<b> in the command syntax) will accept the VARB substitution.
Commands with a real or integer command field (<r> or <i> in the command syntax) will
accept VAR, VARI, READ, DREAD, DREADF, TW or DAT.
Assignment and Comparison Operators
Comparison and assignment operators are used in command arguments for various functions
such as variable assignments, conditional branches, wait statements, conditional GOs, etc.
Some examples are listed below:
•
•
•
•
Assign to numeric variable #6 the value of the encoder position on axis #3 (uses the PE
operator): VAR6=3PE
Wait until onboard inputs #3 & #6 become active (uses the IN operator):
WAIT(IN=bxx1xx1)
Continue until the value of numeric variable #2 is less than 36: UNTIL(VAR2<36)
IF condition based on if a target zone timeout occurs on axis 2 (uses the AS axis status
operator, where status bit #25 is set if a target zone timeout occurs): IF(2AS.25=b1)
The available comparison and assignment operators are listed below. For full descriptions,
refer to their respective descriptions in the Gem6K Series Command Reference
(be sure to refer only to the commands in brackets—e.g., A is the acceleration setup
command, but [ A ] is the acceleration assignment/comparison operator).
Chapter 1. Programming Fundamentals
7
www.comoso.com
* denotes operators that
have a correlated status
display command.
(e.g., To see a full-text
description of each axis
status bit accessed with
the AS operator, send
the TASF command to
the Gem6K controller.)
See page 222.
8
A ................... Acceleration
AD................. Deceleration
ANI .............. Voltage at the analog inputs on an expansion I/O brick (see page 91 for bit patterns) *
ANO .............. Voltage at the analog outputs on an expansion I/O brick (see page 91 for bit patterns) *
AS................. Axis status *
ASX .............. Extended axis status (additional axis status items) *
D ................... Distance
DAC .............. Digital-to-analog converter (output voltage) value *
DAT .............. Data program number
DKEY............ Value of RP240 Key
DPTR............ Data pointer location *
DREAD ......... Data from the numeric keypad on the RP240
DREADF ....... Data from the function keypad on the RP240
ER................. Error status *
FB................. Position of current selected feedback sources *
FS................. Following status *
IN................. Input status (input bit patterns provided on page 91) *
INO .............. “Other” input status (ENABLE input reported with bit #6) *
LIM .............. Limit status (end-of-travel limits and home limits) *
MOV .............. Axis moving status
NMCY............ Current master cycle number *
OUT .............. Output status (output bit patterns provided on page 91) *
PANI............ Position of analog input, at 205 counts/volts unless otherwise scaled (servo axes) *
PC................. Commanded position *
PCC .............. Captured commanded position *
PCE .............. Captured encoder position *
PCME............ Captured master encoder position *
PCMS............ Captured master cycle position *
PER .............. Position error (servo axes only) *
PME .............. Current master encoder position *
PMAS............ Current master cycle position *
PE................. Position of encoder *
PSHF............ Net position shift since constant Following ratio *
PSLV............ Current commanded position of the slave axis *
READ............ Read a numeric value to a numeric variable (VAR)
SC................. Controller status *
SCAN............ Runtime of the last scanned PLC program *
SEG .............. Number of segments available in Compiled Profile memory *
SS................. System status *
SWAP............ Current active status of tasks *
TASK............ Number of the controlling task *
TIM .............. Timer value *
TRIG............ Trigger interrupt status *
TW................. Thumbwheel data read
US................. User status *
V ................... Velocity (programmed)
VAR .............. Numeric variable substitution
VARI............ Integer variable substitution
VARB............ Binary variable substitution
VEL .............. Velocity (commanded by the controller) *
VELA............ Velocity (actual, as measured by a position feedback device) *
VMAS............ Current velocity of the master axis *
Gem6K Series Programmer’s Guide
www.comoso.com
Bit Select Operator
The bit select operator (.) makes it easier to base a command argument on the condition of one
specific status bit. For example, if you wish to base an IF statement on the condition that a
user fault input is activated (error status bit #7 is a binary status bit that is “1” if a user fault
occurred and “Ø” if it has not occurred), you could use this command: IF(ER=bxxxxxx1).
Using a bit select operator, you could instead use this command: IF(ER.7=b1).
Side Note: You can use a bit select operator to set a particular status bit (e.g., to turn on onboard
programmable output #5, you would type the OUT.5-1 command; to enable error-checking bit
#4 to check for drive faults, you would type the ERROR.4-1 command). . You can also check
specific status bits (e.g., to check axis 2’s axis status bit #25 to see if a target zone timeout
occurred, type the 2TAS.25 command and observe the response).
Binary and Hex
Values
When making assignments with or comparisons against binary or hexadecimal values, you must
precede the binary value with the letter “b” or “B”, and the hex value with “h” or “H”.
Examples: IF(IN=b1xØ1) and IF(IN=h7F). In the binary syntax, an “x” simply means
the status of that bit is ignored. Refer also to Using Binary Variables (page 19).
Related Operator
Symbols
Command arguments include special operator symbols (e.g., +, /, &, ', >=, etc.) to perform
bitwise, mathematical, relational, logical, and other special functions. These operators are
described in detail, along with programming examples, at the beginning of the Command
Descriptions section of the Gem6K Series Command Reference.
Programmable Inputs and Outputs Bit Patterns
I/O pin outs,
specifications, and
circuit drawings are
provided in each
Gem6K Series
Hardware Installation
Guide.
The Gem6K product has programmable inputs and outputs. The total number of onboard inputs
and outputs (trigger inputs, limit inputs, digital outputs) depends on the product. The total
number of expansion inputs and outputs (analog inputs, digital inputs and digital outputs)
depends on your configuration of expansion I/O bricks connected to the “EXPANSION I/O”
connector.
These programmable I/O are represented by binary bit patterns, and it is the bit pattern that you
reference when programming and checking the status of specific inputs and outputs. The bit
pattern is referenced in commands like WAIT(IN.4=b1), which means wait until onboard
programmable input #4 (TRG-2B) becomes active. To ascertain your product’s I/O offering
and bit patterns, refer to Chapter 3 (page 91).
Chapter 1. Programming Fundamentals
9
www.comoso.com
Creating Programs
Reminder:
The Motion Planner Wizards interface makes programming easy, eliminates the need to
learn the programming language and frees you from concerning yourself with syntax errors.
A Start Wizard guides you through creating your program structure and configuring your
Gem6K (drives, feedback, I/O, servo tuning, etc.). Additional wizards guide you through all
other programming tasks, such as creating motion profiles, I/O handling, error handling,
program logic and branching, etc. The Tag Name Dictionary allows you to label variables,
axes, I/O so that you can program in terms that are relevant to your machine. If you have
existing programs in an Editor, you can easily include them into the Wizard editor, so you
don’t have to rewrite your code. For additional details about the Wizards programming
interface, refer to page 2.
A program is a series of commands. These commands are executed in the order in which they
are programmed. Immediate commands (commands that begin with an exclamation point [!])
cannot be stored in a program. Only buffered commands may be used in a program. Refer to
the program example below.
A subroutine is defined the same as a program, but it is executed with an unconditional branch
command, such as GOSUB, GOTO, or JUMP, from another program (see page 23 for details
about unconditional branching). Subroutines can be nested up to 16 levels deep. NOTE: The
Gem6K family does not support recursive calling of subroutines.
Debugging Programs:
Refer to page 221 for
methods to isolate and
resolve programming
problems.
Compiled profiles & PLC programs are defined like programs, using the DEF and END
commands, but are compiled with the PCOMP command and executed with the PRUN
command (PLC programs are usually launched in PLC Scan Mode with the SCANP
command). Compiled profiles and PLC programs also affect a different part of the product's
memory, called compiled memory. A compiled profile is an individual axis profile (a series of
GOBUF commands). A compiled PLC program is a pre-compiled program that mimics PLC
functionality by scanning through the I/O faster than in normal program execution. For
information on compiled profiles, refer to page 139; and for information on PLC programs,
refer to page 120.
Program Example
The illustration below identifies the elements that comprise the general structure of a program.
Use DEF to
begin
defining the
program.
Use DEL to
delete the
program (a
precaution).
Contents of the
program.
Use END to
finish defining
the program.
; *********************************************************
; This is a program that executes a trapezoidal motion
; profile on axes 1 and 2
; *********************************************************
DEL motion
; (a precaution) Delete program called "motion"
DEF motion
; Begin definition of program called "motion"
DRIVE1
MC0
A20
V8
D100000
GO
;
;
;
;
;
;
END
; End definition of program called "motion"
Enable drives on axes 1 and 2
Set position mode to preset
Set accel to 20 units/sec/sec
Set velocity to 8 units/sec, and
Set distance to 100,000 counts on axis 1, and
Execute motion
These are command line comments, comprising a semi-colon and text.
The comments are separated from the command by a tab.
A carriage return is placed at the end of each command line.
10
Gem6K Series Programmer’s Guide
www.comoso.com
Storing Programs
After a program or compiled program/profile is defined (DEF) or downloaded to the Gem6K
controller, it is automatically stored in non-volatile memory (battery-backed RAM).
Information on controlling memory allocation is provided below (see Memory Allocation).
Memory Allocation
Your controller's memory has two partitions: one for storing programs and one for storing
compiled profiles & PLC programs. The allocation of memory to these two areas is
controlled with the MEMORY command.
“Programs” vs. ”Compiled Profiles & PLC Programs”
Programs are defined with the DEF and END commands, as demonstrated in the Program
Example on page 10.
Compiled Profiles & PLC Programs are defined like programs, using the DEF and END
commands, but are compiled with the PCOMP command and executed with the
PRUN command (PLC programs are usually executed in PLC Scan Mode with the
SCANP). A compiled profile (a series of GOBUF commands). A PLC program is a
pre-compiled program that mimics PLC functionality by scanning through the I/O
faster than in normal program execution.
Programs intended to be compiled are stored in program memory. After they are
compiled with the PCOMP command, they remain in program memory and the
segments (see diagram below) from the compiled program are stored in compiled
memory. The TDIR report indicates which programs are compiled as compiled
profiles (“COMPILED AS A PATH”) and which programs are compiled as PLC
programs (“COMPILED AS A PLC PROGRAM”) .
For information on compiled profiles, refer to Compiled Motion Profiling on page
139; and for information on PLC programs, refer to page 120.
MEMORY
command
syntax
(example)
MEMORY150000,150000
Memory allocation for
Programs (bytes).
Storage requirements
depend on the number of
ASCII characters in the
program.
Memory allocation for Compiled Profiles & Programs (bytes).
Storage requirements depend on the number of segments
(1 segment consumes 76 bytes). A segment could be one of
these commands:
Compiled Motion:
GOBUF *
PLOOP
GOWHEN
TRGFN
POUTA
POUTB
PLC (PLCP ) Program:
IF **
ELSE
NIF
L
LN
OUT
ANO
EXE
PEXE
VARI **
VARB **
* GOBUF commands may require up to 4 segments.
** IF statement require at least 2 segments, each AND or OR
compound requires an additional segment. VARI and
VARB each require 2 segments.
Chapter 1. Programming Fundamentals
11
www.comoso.com
The table below identifies memory allocation defaults and limits for all Gem6K Series
products. When specifying the memory allocation, use only even numbers. The minimum
storage capacity for one partition area (program or compiled) is 1,000 bytes.
Feature
All Other Products
Total memory (bytes)
300,000
Default allocation (program,compiled)
Maximum allocation for programs
Maximum allocation for compiled profiles
& PLC programs
Max. # of programs
150000,150000
299000,1000
1000,299000
Max. # of labels
Max. # of compiled profiles & PLC programs
Max. # of compiled profile segments
Max. # of numeric variables (VAR)
600
300
2069
225
Max. # of integer variables (VARI)
225
Max. # of binary variables (VARB)
125
Max. # of string variables (VARS)
25
400
When teaching variable data to a data program (DATP), be aware that the memory required
for each data statement of four data points (43 bytes) is taken from the memory allocation for
program storage (see Variable Arrays in Chapter 3, page 110, for details).
CAUTION
Using a memory allocation command (e.g., MEMORY200000,100000) will erase all existing
programs and compiled profile segments & PLC programs. However, issuing the MEMORY
command without parameters (i.e., type MEMORY <cr> to request the status of how the
memory is allocated) will not affect existing programs or compiled segments/programs.
Checking Memory Status
To find out what programs reside in your controller's memory, and how much of the available
memory is allocated for programs and compiled profile segments, issue the TDIR command
(see example response below). Entering the TMEM command or the MEMORY command
(without parameters) will also report the available memory for programs and compiled profile
segments.
Sample response to
TDIR command
*1 - SETUP USES 345 BYTES
*2 - PIKPRT USES 333 BYTES
*149322 OF 150000 BYTES (98%) PROGRAM MEMORY REMAINING
*1973 OF 1973 SEGMENTS (100%) COMPILED MEMORY REMAINING
Two system status bits (reported with the TSS and SS commands) are available to check when
compiled profile segment storage is 75% full or 100% full. System status bit #29 is set when
segment storage reaches 75% of capacity; bit #30 indicates when segment storage is 100% full.
12
Gem6K Series Programmer’s Guide
www.comoso.com
Executing Programs (options)
Following is a list of the primary options for executing programs stored in your controller:
Method
Description
See Also
Execute from a terminal
emulator
Type in the name of the program and press enter; or write a
program to prompt the operator to select a program from the
terminal.
-------
Execute as a subroutine
from a “main” program
Use a branch (GOTO, GOSUB, or JUMP) from the main program to
execute another stored program.
Page 23
Execute automatically
when the controller is
powered up
Assign a specific program as a startup program with the STARTP
command. When you RESET or cycle power to the controller, the
startup program is automatically executed.
Page 13
Execute from a PLC
program
Write a PLC program that executes a program (using EXE or PEXE)
based on a specific condition (e.g., input state). Use the SCANP
command to launch the PLC program in the PLC Scan Mode.
Page 120
Execute a specific
program with BCD
weighted inputs
Define programmable inputs to function as BCD select inputs, each
with a BCD weight. A specific program (identified by its number) is
executed based on the combination of active BCD inputs. Related
commands: INSELP and INFNCi-B or LIMFNCi-B.
Page 97
Execute a specific
program with a
dedicated input
Define a programmable input to execute a specific program (by
number). Related commands: INSELP and INFNCi-iP or
LIMFNCi-P.
Page 103
“Call” from a high-level
program
Using a programming language such as BASIC or C, write a
program that enables the computer to monitor processes and
orchestrate motion and I/O by executing stored programs (or
individual commands) in the controller.
Page 133
Execute from an RP240
(remote operator
interface)
Execute a stored program from the RUN menu in the RP240’s
standard menu system.
Page 127
Execute from your own
custom Windows
program
Use a programming language (e.g., Visual Basic, Visual C++, etc.)
and the Gem6K Communications Server (provided on the Motion
Planner CD) to create your own windows application to control the
Gem6K product. Also included with Motion Planner is PanelMaker,
a Visual Basic scripting tool for developing your own customer user
interfaces.
---------
Creating and Executing a Set-up Program
Wizards Can Help:
The Motion Planner
Start Wizard helps you
with these setup
programming tasks:
• Create a Setup
program that
configures drives,
feedback devices,
scaling, limits (end of
travel and home),
and servo tuning.
• Create a Main
program, establish it
as the power-up
(STARTP) program,
and include a
GOSUB to the Setup
program.
The intent of the Setup program is to place the Gem6K controller in a ready state for
subsequent motion control. The setup program must be called from the “main” program for
your application; or you can designate (with STARTP) the setup program as the program to be
automatically executed when the Gem6K product is powered up or when the RESET command
is executed. The setup program typically contains elements such as feedback device
configuration, tuning gain selections, programmable I/O definitions, scaling, homing
configuration, variable initialization, etc. (more detail on these “basic” features is provided in
Chapter 3, Basic Operation Setup).
The basic process of creating a setup program is:
1. Create a program to be used as the setup program.
2. Save the program and download it to the Gem6K product.
3. Execute the STARTP command to assign your new program as the “start-up” program
(e.g., STARTP setup assigns the program called “setup” as the start-up program). The
next time the controller is powered up or reset, the assigned STARTP program will be
executed.
Or call the setup program from the main program for your application.
Chapter 1. Programming Fundamentals
13
www.comoso.com
Program Security
Issuing the INFNCi-Q or LIMFNCi-Q command enables the Program Security feature and
assigns the Program Access function to the specified programmable input. The “i” represents
the number of the programmable input to which you wish to assign the function (see page 91
programmable input bit patterns for your product).
The program security feature denies you access to the DEF, DEL, ERASE, MEMORY, INFNC,
and LIMFNC commands until you activate the program access input. Being denied access to
these commands effectively restricts altering the user memory allocation. If you try to use
these commands when program security is active (program access input is not activated), you
will receive the error message *ACCESS DENIED.
For example, once you issue the INFNC5-Q command, onboard input #5 is assigned the
program access function and access to the DEF, DEL, ERASE, MEMORY, INFNC, and
LIMFNC commands will be denied until you activate onboard input #5.
NOTE: To regain access to these commands without the use of the program access input, you
must issue the INEN command to disable the program security input, make the required user
memory changes, and then issue the INEN command to re-enable the input. For example, if
input 3 on I/O brick 2 is assigned as the Program Security input, use 2INEN.3=1 to disable
the input and leave it activated, make the necessary user memory changes, and then use
2INEN.3=E to re-enable the input.
Controlling Execution of Programs and the Command Buffer
The Gem6K controller command buffer is capable of storing 2000 characters waiting to be
processed. (This is separate from the memory allocated for program storage – see Memory
Allocation, page 11.) COMEXC affects command execution. Three additional commands,
COMEXL, COMEXR and COMEXS, affect the execution of programs and the command buffer.
COMEXC (Continuous Command Execution)
The COMEXC1 command enables the Continuous Command Execution Mode (default is
COMEXC0). This mode allows the program to continue to the next command before motion is
complete. This is useful for:
• Monitoring other processes while motion is occurring
• Performing calculations in advance of motion completion
• Pre-emptive GOs — executing a new profile with new attributes (distance, accel/decel,
velocity, positioning mode, and Following ratio ) before motion is complete: The
motion profile underway is pre-empted with a new profile when a new GO is issued.
The new GO both constructs and launches the pre-empting profile. Pre-emptive GOs are
appropriate when the desired motion parameters are not known until motion is already
underway. For a detailed description, refer to On-The-Fly Motion on page 155.
• Pre-process the next move while the current move is in progress (see CAUTION note).
This reduces the processing time for the subsequent move to only a few microseconds.
CAUTION: Avoid executing moves prematurely
With continuous command execution enabled (COMEXC1), if you wish motion to stop before
executing the subsequent move, place a WAIT(AS.1=bØ) statement before the
subsequent GO command. If you wish to ensure the load settles adequately before the next
move, use the WAIT(AS.24=b1) command instead (this requires you to define end-ofmove settling criteria — see Target Zone Mode on page 84 for details).
14
Gem6K Series Programmer’s Guide
www.comoso.com
In the programming example below, by enabling the continuous command execution mode
(COMEXC1), the controller is able to turn on output #3 after the encoder moves 4000 units of
its 125000-unit move. Normally, with COMEXC disabled (COMEXCØ), command processing
would be temporarily stopped at the GO1 command until motion is complete.
Programming Example (portion of program only)
COMEXC1
;Enable continuous command execution mode
D125000
;Set distance
V2
;Set velocity
A10
;Set acceleration
GO1
;Initiate motion on axis 1
WAIT(1PE>4000)
;Wait for the encoder position to exceed 4000
OUTXX1
;Turn on onboard programmable output #3
WAIT(AS.1=b0)
;Wait for motion to complete on axis 1 (AS bit #1 = zero)
OUTXX0
;Turn off onboard programmable output #3
COMEXL (Save Command Buffer on Limit)
The COMEXL command enables saving the command buffer and maintaining program
execution when a hardware or software end-of-travel limit is encountered. COMEXL is axis
specific (e.g., COMEXL1xx1xxx1 enables saving the buffer for axes 1, 4, and 8).
For more information
on end-of-travel limits,
refer to page 74.
• COMEXL0: (This is the default setting.) When a limit is hit, every command in the
command buffer will be discarded and program execution will be terminated.
• COMEXL1: When a limit is hit, all remaining commands in the command buffer will
remain in the command buffer (excluding the command being executed at the time the
limit is hit).
COMEXR (Effect of Pause/Continue Input)
The COMEXR command affects whether a “Pause” input (i.e., an input configured as a
pause/continue input with the INFNCi-E command or the LIMFNCi-E command) will pause
only program execution or both program execution and motion.
COMEXRØ: (This is the default setting.) Upon receiving a pause input, only program execution
will be paused; any motion in progress will continue to its predetermined destination.
Releasing the pause input or issuing a !C command will resume program execution.
COMEXR1: Upon receiving a pause input, both motion and program execution will be paused;
the motion stop function is used to halt motion. After motion has come to a stop
(not during deceleration), you can release the pause input or issue a !C command
to resume motion and program execution.
Other Ways to Pause
• Issue the PS command before entering a series of buffered commands (to cause motion,
activate outputs, etc.), then issue the !C command to execute the commands.
• While program execution is in progress, issuing the !PS command stops program execution,
but any move currently in progress will be completed. Resume program execution with the !C
command.
Chapter 1. Programming Fundamentals
15
www.comoso.com
COMEXS (Save Command Buffer on Stop)
The COMEXS command determines the impact on motion, program execution, and the
command buffer when the Gem6K receives a Stop command (S, !S, S1, or !S1) or an
external Stop input (an input assigned a stop function with INFNCi-D or LIMFNCi-D).
COMEXS0: Under factory default conditions (COMEXS0), when the Gem6K receives a stop
command (S, !S, S1, or !S1) or a stop input (INFNCi-D or LIMFNCi-D), the
following will happen:
• Motion decelerates to a stop, using the present AD and ADA deceleration
values. The motion profile cannot be resumed.
• If S, !S or Stop input:
– All commands in the Gem6K’s command buffer are discarded.
– Program execution is terminated and cannot be resumed.
• If S1, or !S1 (an axis number is included in the command):
– All commands in the Gem6K’s command buffer are retained.
– Program execution continues.
COMEXS1: Using the COMEXS1 mode, the Gem6K allows more flexibility in responding to
stop conditions, depending on the stop method (see table below).
Stop Method
!S or S
!S1 or S1
Stop input
Pause input *
(if COMEXR1)
Pause input *
(if COMEXR0)
What Stops?
Motion Program
Resume Motion Profile.
(Allow resume with a !C
command or a resume
input * )
Resume Program.
(Allow resume with a
!C command or a
resume input * )
Save Command Buffer.
(Save the commands that
were in the command
buffer when the stop was
commanded)
Yes
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
No
No
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
No
Yes
Yes
* A Pause input is an input configured with the INFNCi-E command or the LIMFNCi-E command. This is also
the Resume input that can be used to resume motion and program execution after motion is stopped.
COMEXS2: Using the COMEXS2 mode, the Gem6K responds as it does in the COMEXS0 mode,
with the exception that you can still use the program-select inputs to select programs
(INSELP value is retained). The program-select input functions are: BCD select
(INFNCi-B or LIMFNCi-B) – see page 97, and one-to-one select (INFNCi-P or
LIMFNCi-P) – see page 103.
16
Gem6K Series Programmer’s Guide
www.comoso.com
Restricted Commands During Motion
When motion is in progress on a given axis (or task), some commands cannot have their
parameters changed until motion is complete (see table below).
For the commands identified in the table, if the continuous command execution mode is
enabled (COMEXC1) and you try to enter new command parameters, you will receive the error
response MOTION IN PROGRESS. If the continuous command execution mode in disabled
(COMEXCØ), which is the default setting, you will receive the response MOTION IN
PROGRESS only if you precede the command with the immediate (!) modifier (e.g., !V2Ø);
if you enter a command without the immediate modifier (e.g., V2Ø), you will not receive an
error response and the new parameter will be ignored and the old parameter will remain in
effect.
Multi-Tasking
If you are using multi-tasking, the restriction on commands is applicable only for the task to
which the command is direct. For example, suppose axes 1 and 2 are associated with Task 1
(TSKAX1,2) and axes 3 and 4 are associate with Task 2 (TSKAX3,4). If motion is in progress
on axes 1 and 2, Task 1 is considered “in motion” and Task 1 cannot execute a command
from the list below. However, while motion is in progress in Task 1 and not Task 2, Task 2
may execute these commands without encountering an error.
All of the commands in the table below, except for SCALE, are axis-dependent. That is, if
one axis is moving you can change the parameters on the other axes, provided they are not in
motion.
Command Description
CMDDIR......... Commanded Direction Polarity
DRES ............. Drive Resolution
DRIVE........... Drive Shutdown
ENCPOL......... Encoder Polarity
ERES ............. Encoder Resolution
FOLEN ...........Following Mode Enable
HOM ............... Go Home
HOMA ............. Home Acceleration
HOMAA........... Average Home Acceleration
HOMAD........... Home Deceleration
HOMADA......... Average Home Deceleration
HOMV ............. Home Velocity
HOMVF........... Home Final Velocity
JOG ............... Jog Mode Enable
JOGA ............. Jog Acceleration
JOGAA........... Average Jog Acceleration
JOGAD........... Jog Deceleration
JOGADA......... Average Jog Deceleration
JOGVH........... Jog Velocity High
JOGVL........... Jog Velocity Low
Command Description
JOY............... Joystick Mode Enable
JOYA............. Joystick Acceleration
JOYAA .......... Average Joystick Acceleration
JOYAD .......... Joystick Deceleration
JOYADA ........ Average Joystick Deceleration
JOYVH .......... Joystick Velocity High
JOYVL .......... Joystick Velocity Low
LHAD............. Hard Limit Deceleration
LHADA .......... Average Hard Limit Deceleration
LSAD............. Soft Limit Deceleration
LSADA .......... Average Soft Limit Deceleration
PSET............. Establish Absolute Position
SCALE .......... Enable/Disable Scale Factors *
SCLA............. Acceleration Scale Factor
SCLD............. Distance Scale Factor
SCLV............. Velocity Scale Factor
* If any axis is in motion, you will cause an error if you attempt to change this command's parameters.
Chapter 1. Programming Fundamentals
17
www.comoso.com
Variables
Gem6K Series controllers have four types of variables, each designated with a different
command. All four types are automatically stored in non-volatile memory.
Type
Numeric
(real)
Command
VAR
Quantity Function
225
Store real numeric data (range is ±999,999,999.99999999). Can be
used to perform mathematical (=, +, -, *, /, SQRT), trigonometric
(ATAN, COS, PI, SIN, TAN), and Boolean (&, |, ^, ~) operations.
Can also be used to store (“teach”) variable data in variable arrays
(called data programs) and later use the stored data as a source for
motion program parameters (see Variable Arrays on page 110 for
details).
Integer
VARI
225
Binary
VARB
125
String
VARS
25
Store integer numeric data (range is ±2,147,483,647). Can be used
to perform mathematical (=, +, -, *, /) and Boolean (&, |, ^, ~)
operations.
Store 32-bit binary or hexadecimal values. Can also store the binary
status bits from status registers. Frequently used registers are:
inputs (IN), outputs (OUT), limits (LIM), system (SS), Following (FS),
axis (AS & ASX), and error (ER). For example, the VARB2=IN.3
command assigns the binary state of input 12 to binary variable 2.
Also use to perform bitwise operations (&, |, ^, ~, >>, <<).
Store message strings of 50 characters or less. These message
strings can be predefined error messages, user messages, etc.
The programming example in the Command Value Substitutions
(page 7) demonstrates the use of a string variable.
Enhancements as of OS revision 5.1.0:
• Copy one VARS variable to another VARS variable.
VARSn=VARSm may be used, as well as variable substitutions
for “n” and “m”.
• VARS message string was increased from 20 to 50 characters.
NOTE: Variables do not share the same memory (e.g., VAR1, VARI1, VARB1, and VARS1 can all exist
at the same time and operate separately).
Converting Between Binary and Numeric Variables
Using the Variable Type Conversion (VCVT) operator, you can convert numeric (VAR or
VARI) values to binary (VARB) values, and vice versa. The operation is a signed operation as
the binary value is interpreted as a two's complement number. Any don't cares (x) in a binary
value is interpreted as a zero (Ø).
If the mathematical statement's result is a numeric value, then VCVT converts binary values to
numeric values. If the statement's result is a binary value, then VCVT converts numeric values
to binary values.
Numeric to Binary
Binary to Numeric
Example
Description/Response
VAR1=-5
VARB1=VCVT(VAR1)
VARB1
Set numeric variable value = -5
Convert the numeric value to a binary value
*VARB1=1101_1111_1111_1111_1111_1111_1111_1111
Example
Description/Response
VARB1=b0010_0110_0000_0000_0000_0000_0000_0000
Set binary variable = +100.0
Convert binary value to numeric
VAR1=VCVT(VARB1)
VAR1
*VAR1=+100.0
18
Gem6K Series Programmer’s Guide
www.comoso.com
Using Numeric (VAR and VARI) Variables
NOTES
• The examples below show the use of real numeric variables (VAR). Integer variables may
be used in the same operations with these exceptions:
- Values are truncated to nearest integer value
- Operations using square root (SQRT) and trigonometric (ATAN, COS, PI, SIN, TAN)
operators are not allowed
• Some numeric variable operations reduce precision. The following operations reduce the
precision of the return value: Division and Trigonometric functions yield 5 decimal places;
Square Root yields 3 decimal places; and Inverse Trigonometric functions yield 2 decimal
places.
Mathematical
Operations
Addition (+)
The following examples demonstrate how to perform math operations with numeric variables.
Operator precedence occurs from left to right (e.g., VAR1=1+1+1∗3 sets VAR1 to 9, not 5).
Example
VAR1=5+5+5+5+5+5+5
VAR1
VAR23=1000.565
VAR11=VAR1+VAR23
VAR11
VAR1=VAR1+5
VAR1
Subtraction (-)
Multiplication (*)
Division (/)
*VAR1=35.0
*VAR11=+1035.565
*VAR1=+40.0
Example
Response
VAR3=20-10
VAR20=15.5
VAR3=VAR3-VAR20
VAR3
*VAR3=-5.5
Example
Response
VAR3=10
VAR3=VAR3*20
VAR3
*VAR3=+200.0
Example
Response
VAR3=10
VAR20=15.5
VAR20
VAR3=VAR3/VAR20
VAR3
VAR30=75
VAR30
VAR19=VAR30/VAR3
VAR19
Square Root (SQRT)
Response
Example
*+15.5
*+0.64516
*+75.0
*+116.25023
Response
VAR3=75
VAR20=25
VAR3=SQRT(VAR3)
VAR3
*+8.660
VAR20=SQRT(VAR20)+SQRT(9)
VAR20
*+8.0
Chapter 1. Programming Fundamentals
19
www.comoso.com
Trigonometric
Operations
Example
Sine
RADIAN0
VAR1=SIN(0)
VAR1
VAR1=SIN(30)
VAR1
VAR1=SIN(45)
VAR1
VAR1=SIN(60)
VAR1
VAR1=SIN(90)
VAR1
RADIAN1
VAR1=SIN(0)
VAR1
VAR1=SIN(PI/6)
VAR1
VAR1=SIN(PI/4)
VAR1
VAR1=SIN(PI/3)
VAR1
VAR1=SIN(PI/2)
VAR1
Cosine
20
The examples below demonstrate how to perform trigonometric operations with numeric
variables.
Example
RADIAN0
VAR1=COS(0)
VAR1
VAR1=COS(30)
VAR1
VAR1=COS(45)
VAR1
VAR1=COS(60)
VAR1
VAR1=COS(90)
VAR1
RADIAN1
VAR1=COS(0)
VAR1
VAR1=COS(PI/6)
VAR1
VAR1=COS(PI/4)
VAR1
VAR1=COS(PI/3)
VAR1
VAR1=COS(PI/2)
VAR1
Gem6K Series Programmer’s Guide
Response
*VAR1=+0.0
*VAR1=+0.5
*VAR1=+0.70711
*VAR1=+0.86603
*VAR1=+1.0
*VAR1=+0.0
*VAR1=+0.5
*VAR1=+0.70711
*VAR1=+0.86603
*VAR1=+1.0
Response
*VAR1=+1.0
*VAR1=+0.86603
*VAR1=+0.70711
*VAR1=+0.5
*VAR1=+0.0
*VAR1=+1.0
*VAR1=+0.86603
*VAR1=+0.70711
*VAR1=+0.5
*VAR1=+0.0
www.comoso.com
Tangent
Inverse Tangent
(Arc Tangent)
Boolean Operations
Boolean And (&)
Boolean Or (|)
Boolean Exclusive
Or (^)
Boolean Not (~)
Example
RADIAN0
VAR1=TAN(0)
VAR1
VAR1=TAN(30)
VAR1
VAR1=TAN(45)
VAR1
VAR1=TAN(60)
VAR1
RADIAN1
VAR1=TAN(0)
VAR1
VAR1=TAN(PI/6)
VAR1
VAR1=TAN(PI/4)
VAR1
VAR1=TAN(PI/3)
VAR1
Example
RADIAN0
VAR1=SQRT(2)
VAR1=ATAN(VAR1/2)
VAR1
VAR1=ATAN(.57735)
VAR1
Response
*VAR1=+0.0
*VAR1=+0.57735
*VAR1=+1.0
*VAR1=+1.73205
*VAR1=+0.0
*VAR1=+0.57735
*VAR1=+1.0
*VAR1=+1.73205
Response
*VAR1=+35.26
*VAR1=+30.0
Gem6K Series products have the ability to perform Boolean operations with numeric variables.
The following examples illustrate this capability. Refer to the Gem6K Series Command
Reference for more information on each operator (&, |, ^, and ~).
Example
Response
VAR1=5
VAR2=-1
VAR3=VAR1 & VAR2
VAR3
*VAR3=+0.0
Example
Response
VAR1=5
VAR2=-1
VAR3=VAR1 | VAR2
VAR3
*VAR3=+1.0
Example
Response
VAR1=5
VAR2=-1
VAR3=VAR1 ^ VAR2
VAR3
*VAR3=+1.0
Example
Response
VAR1=5
VAR3=~(VAR1)
VAR3
VAR1=-1
VAR3=~(VAR1)
VAR3
*VAR3=+0.0
*VAR3=+1.0
Chapter 1. Programming Fundamentals
21
www.comoso.com
Using Binary Variables
The following examples illustrate the Gem6K Series product's ability to perform bitwise
functions with binary variables.
Storing binary values. The Gem6K Series Language allows you to store binary numbers in
the binary variables (VARB) command. The binary variables start at the left with the least
significant bit, and increase to the right. For example, to set bit 1, 5, and 7 you would issue
the command VARB1=b1xxx1x1. Notice that the letter b is required. When assigning a
binary variable, any bit set to “x” remains “x” until set to “1” or “0”. Any bit that is
unspecified is set to “x”. To change, or check, one bit without affecting the others, use the bitselect operator (e.g., use VARB1.3-1 to set only bit #3 of VARB1).
Example
Response
VARB1=b1101XX1
*VARB1=1101_XX1X_XXXX_XXXX_XXXX_XXXX_XXXX_XXXX
Storing hexadecimal values. Hexadecimal values can also be stored in binary variables
(VARB). The hexadecimal value must be specified the same as the binary value—left is least
significant byte, right is most significant. For example, to set bit 1, 5, and 7 you would issue
the command VARB1=h15. Notice that the letter h is required. NOTE: When assigning a
hexadecimal value to a binary variable, all unspecified bits are set to zero.
Bitwise And (&)
Example
Response
VARB1=h7FAD
VARB1
*VARB1=1110_1111_0101_1011_0000_0000_0000_0000
Example
Response
VARB1=b1101
VARB1
*VARB1=1101_XXXX_XXXX_XXXX_XXXX_XXXX_XXXX_XXXX
VARB1=VARB1 & bXXX1 1101
VARB1
*VARB1=XX01_XX0X_XXXX_XXXX_XXXX_XXXX_XXXX_XXXX
VARB1=h0032 FDA1 & h1234 43E9
VARB1
*VARB1=0000_0000_1100_0000_0010_1000_0101_1000
Bitwise Or (|)
Example
Response
VARB1=h32FD
VARB1
*VARB1=1100_0100_1111_1011_0000_0000_0000_0000
VARB1=VARB1 | bXXX1 1101
VARB1
*VARB1=11X1_1101_1111_1X11_XXXX_XXXX_XXXX_XXXX
VARB1=h0032 FDA1 | h1234 43E9
VARB1
*VARB1=1000_0100_1100_0110_1111_1111_0111_1001
Bitwise Exclusive
Or (^)
Bitwise Not (~)
Example
Response
VARB1=h32FD ^ bXXX1 1101
VARB1
*VARB1=XXX1_1001_XXXX_XXXX_XXXX_XXXX_XXXX_XXXX
VARB1=h0032 FDA1 ^ h1234 43E9
VARB1
*VARB1=1000_0100_0000_0110_1101_0111_0010_0001
Example
Response
VARB1=~(h32FD)
VARB1
*VARB1=0011_1011_0000_0100_1111_1111_1111_1111
VARB1=~(b1010 XX11 0101)
VARB1
*VARB1=0101_XX00_1010_XXXX_XXXX_XXXX_XXXX_XXXX
Shift Left to Right
(>>)
Shift Right to Left
(<<)
22
Example
Response
VARB1=h32FD >> h4
VARB1
*VARB1=0000_1100_0100_1111_1011_0000_0000_0000
VARB1=b1010 XX11 0101 >> b11
VARB1
*VARB1=0001_010X_X110_101X_XXXX_XXXX_XXXX_XXXX
Example
Response
VARB1=h32FD << h4
VARB1
*VARB1=0100_1111_1011_0000_0000_0000_0000_0000
VARB1=b1010 XX11 0101 << b11
VARB1
*VARB1=0XX1_1010_1XXX_XXXX_XXXX_XXXX_XXXX_X000
Gem6K Series Programmer’s Guide
www.comoso.com
Program flow refers to the order in which commands will be executed, and when or whether
they will be executed at all. In general, commands are executed in the order in which they are
received. However, certain commands can redirect the order in which commands will be
processed.
You can affect program flow with:
•
•
Unconditional Loops and Branches
Conditional Loops and Branches
Unconditional Looping and Branching
Unconditional
Looping
The Loop (L) command is an unconditional looping command. You may use this command to
repeat the execution of a group of commands for a predetermined number of iterations. You
can nest Loop commands up to 16 levels deep. The code sample (portion of a program) below
demonstrates a loop of 5 iterations.
MA0
A50
V5
L5
D2000
GO1
T2
LN
Unconditional
Branching
;
;
;
;
;
;
;
;
Sets unit to Incremental mode
Sets acceleration to 50
Sets velocity to 5
Loops 5 times
Sets distance to 2,000
Executes the move (Go)
Delays 2 seconds after the move
Ends loop
When an unconditional branch is processed, the flow of program execution (“control”) passes
to the program or label specified in the branch command. Depending on the branch command
used, processing may or may not return to the original program (the “calling” program). There
are three ways to branch unconditionally:
GOSUB: The GOSUB command branches to the program name or label stated in the GOSUB
command. After the called program or label is executed, processing returns to the
calling program at the next command line after the GOSUB branch command.
GOTO:
The GOTO command branches to the program name or label stated in the GOTO
command. After the called program or label is executed, processing does not return
to the calling program—instead, the program will end. This holds true unless the
subroutine in which the GOTO resides was called with a GOSUB by another
program; in this case, the END in the GOTO program will initiate a return to the
calling program. For example, if processing flows from a GOSUB in program A to
program B, and then a GOTO from program B to program C, when the END
command is processed in program C, processing returns to program A at the
command line after the GOSUB.
JUMP:
The JUMP command branches to the program name or label stated in the JUMP
command. All nested IFs, WHILEs, and REPEATs, loops (L), and subroutines are
cleared; thus, the program or label that the JUMP initiates will not return control to
the calling program; instead, the called program will end.
If an invalid program or label name is entered, the branch command will be ignored and
processing will continue with the next line in the program.
Gem6K Series products do not support recursive calling of subroutines.
Using labels: Labels, defined with the $ command, provide a method of branching to specific
locations within the same program. Labels can only be defined within a program and executed
with a GOTO, GOSUB, or JUMP command from within the same program (see Example B below).
Chapter 1. Programming Fundamentals
23
www.comoso.com
NOTE
Be careful about performing a GOTO within a loop or branch statement area (i.e., between
L & LN, between IF & NIF, between REPEAT & UNTIL, or between WHILE & NWHILE).
Branching to a different location within the same program will cause the next L, IF, REPEAT,
or WHILE statement encountered to be nested within the previous L, IF, REPEAT, or WHILE
statement area, unless an LN, NIF, UNTIL, or NWHILE command has already been
encountered.
** To avoid this nesting situation, use the JUMP command instead of the GOTO command.
Example A
DESCRIPTION: The program cut1 is executed until it gets to the command GOSUB
prompt. From there it branches unconditionally to the subroutine (actually a program) called
prompt. The subroutine prompt queries the operator for the number of parts to process.
After the part number is entered (e.g., operator enters the !'12 command to process 12 parts),
the rest of the prompt subroutine is executed and control goes back to the cut1 program and
resumes program execution with the next command after the GOSUB, which is MAØØ.
DEL cut1
; Delete a program before defining it
DEF cut1
; Begin definition of program cut1
HOM11
; Send axes 1 and 2 to the home position
WAIT(1AS=b0XXX1 AND 2AS=b0XXX1)
; Wait for axes 1 and 2 to come
; to a halt at home
GOSUB prompt
; Go to subroutine program called prompt
MA00
; Place axes 1 and 2 in the incremental mode
A10,30
; Set acceleration: axis 1 = 10, axis 2 = 30
AD5,12
; Set deceleration: axis 1 = 5, axis 2 = 12
V5,8
; Set velocity: axis 1 = 5, axis 2 = 8
D16000,100000
; Set distance: axis 1 = 16,000; axis 2 = 100,000
OUT.3-1
; Turn on onboard output number 3
T5
; Wait for 5 seconds
L(VAR2)
; Begin loop (number of loops = value of VAR2)
GO11
; Initiate moves on axes 1 and 2
T3
; Wait for 3 seconds
LN
; End loop
OUT.3-0
; Turn off onboard output number 3
END
; End definition of program cut1
DEF prompt
; Begin definition of program prompt
VARS1="Enter part count >" ; Place message in string variable #1
VAR2=READ1
; Prompt operator with string variable #1,
; and read data into numeric variable #2
; NOTE: Type !' before the part count number.
END
; End definition of program prompt
Example B
DESCRIPTION: This example demonstrates the use of labels ($).
DEL pick
DEF pick
GO1100
IF(VAR1=5)
GOTO pick1
ELSE
GOTO pick2
NIF
$ pick1
GO0011
BREAK
$ pick2
GO1001
END
24
Gem6K Series Programmer’s Guide
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
Delete a program before defining it
Begin definition of program pick
Initiate motion and axes 1 and 2
If variable 1 = 5, then execute commands
between IF and ELSE. Otherwise, execute
commands between ELSE and NIF
Goto label pick1
Else part of IF statement
Goto label pick2
End of IF statement
Define label for pick1
Initiate motion on axes 3 and 4
Break out of current subroutine or program
Define label for pick2
Initiate motion on axes 1 and 4
End definition of program pick
www.comoso.com
Conditional Looping and Branching
Conditional looping (REPEAT/UNTIL and WHILE/NWHILE) entails repeating a set of
commands until or while a certain condition exists. In conditional branching
(IF/ELSE/NIF), a specific set of commands is executed based on a certain condition. Both
rely on the fulfillment of a conditional expression, a condition specified in the UNTIL,
WHILE, or IF commands.
A WAIT command pauses command execution until a specific condition exists.
Flow Control
Expression
Examples
This section provides examples of expressions that can be used in conditional branching and
looping commands (UNTIL, WHILE, and IF) and the WAIT command. These expressions can
be constructed, in conjunction with relational and logical operators, with the following
operands:
•
•
•
•
•
Numeric and Binary
Variables
•
•
•
•
•
Numeric variables and binary variables
Inputs and outputs
Current motion parameters and status
Current commanded and actual position
Error, axis, and system status
Timer value
Data read from the serial port
Data read from the RP240
Following conditions
Multi-tasking conditions
A numeric variable (VAR or VARI) can be used within an expression if it is compared against
another numeric variable, a value, or one of the comparison commands (see list on page 7).
When comparing a variable against another value, variable, or comparison command, the
relational operators (=, >, >=, <, <=, <>) and logical operators (AND, OR, NOT) are used.
Expression
Description
(VAR1<VAR2)
(VAR1>=2500)
(VAR1=1AD)
(VAR1<VAR2 AND VAR4>1PE)
True expression if variable 1 is less than variable 2
True expression if variable 1 is greater than or equal to 2500
True expression if variable 1 is equal to the decel of axis 1
True expression if variable 1 is less than variable 2 and variable 4
is greater than the value of encoder 1
A binary variable (VARB) can be used within an expression, if the variable is compared against
another binary variable, or a value. When comparing a variable against another value or variable,
the relational operators (=, >, >=, <, <=, <>) and logical operators (AND, OR, NOT) are used.
Expression
Description
(VARB1<>VARB2)
True expression if binary variable 1 is not equal to binary
variable 2
True expression if binary variable 1 is equal to 1101 X111
True expression if binary variable 1 is less than binary
variable 2 and binary variable 4 is greater than the
hexadecimal value of F
(VARB1=b1101 X111)
(VARB1<VARB2 AND VARB4>hF)
Inputs and Outputs
An input or output operand (ANI, IN, INO, LIM, OUT, TRIG) can be used within an
expression, if the operand is compared against a binary variable or a binary or hexadecimal
value. When making the comparison, the relational operators (=, >, >=, <, <=, <>) and logical
operators (AND, OR, NOT) are used.
Expression
(IN.3=b1)
(LIM>h3)
Current Motion
Parameters and
Status
Description
True expression if onboard input 3 is equal to 1
True expression if limit status is greater than hexadecimal 3
Motion parameters consist of A, AD, D, V, VEL, status MOV. The motion parameters can be
used within an expression, if the operand is compared against a numeric variable or value. The
motion status operand must be compared against a binary variable or a binary or hexadecimal
value. When making the comparison, the relational operators (=, >, >=, <, <=, <>) and logical
operators (AND, OR, NOT) are used. (Following conditions are addressed below.)
Chapter 1. Programming Fundamentals
25
www.comoso.com
Expression
Description
(VAR1<1VEL)
True expression if the value of variable 1 is less than the commanded velocity
of axis 1
True expression if axis 1 deceleration equals 25000
True expression if moving status equals ØØ (axes 1 & 2 are not moving)
(1AD=25000)
(MOV=b00)
Current Commanded
& Actual Position
The current commanded and actual positions (ANI, DAC, FB, PANI, PC, PCC, PCE, PCME,
PCMS, PE, PER, PE, PMAS, PME, PSHF, PSLV) can be used within an expression, if the
operand is compared against a numeric variable or value. When making the comparison, the
relational operators (=, >, >=, <, <=, <>) and logical operators (AND, OR, NOT) are used.
Expression
Description
(VAR1<1FB)
True expression if the value of variable 1 is less than the actual position
(position of the assigned feedback device) of axis 1
True expression if axis 2 commanded position equals 4000
True expression if VAR1 is < master encoder position of axis 1
True expression if axis 2 encoder position equals 25000
(2PC=4000)
(VAR1<1PME)
(2PE=25000)
Error, Axis, and
System Status
Timer Value
Data Read from the
Communications Port
The error status, axis status, and system status operands (ER, AS, ASX, SS) can be used within
an expression, if the operand is compared against a binary variable or a binary or hexadecimal
value. When making the comparison, the relational operators (=, >, >=, <, <=, <>) and logical
operators (AND, OR, NOT) are used. Refer to page 222 for a list of status bit functions.
Expression
Description
(ER.12=b1)
(AS=h3FFD)
True expression if error status bit 12 is equal to 1
True expression if axis status is equal to hexadecimal 3FFD
The current timer value (TIM) can be used within an expression, if the operand is compared
against a numeric variable or value. When making the comparison, the relational operators (=,
>, >=, <, <=, <>) and logical operators (AND, OR, NOT) are used.
Expression
Description
(VAR1<TIM)
True expression if the value of variable 1 is less than the timer value
The READ command can be used to input data from a serial port or the Ethernet port into a
numeric variable. After the data has been read into a numeric variable, that variable may be
used in an expression.
Example
Description
Define message (string variable 8)
Send message (string variable 8) and then wait for immediate data to
be read (into numeric variable 2)
Immediate data input (must type !' before the numeric value)
Evaluate expression to see if data read is < or equal to 100
VARS8="ENTER DATA"
VAR2=READ8
!'88.3
IF (VAR2<=100)
. . . . .
End of IF
NIF
Data Read from the
RP240
The DREAD and DREADF commands can be used to input data from the RP240 into a numeric
variable. DREAD reads a number from the RP240's numeric keypad. DREADF reads a number
representing a RP240 function key. After the data has been read into a numeric variable, that
variable may be used in an expression. The DKEY operator allows you to read the current state
of the RP240 keypad (each key has a unique numeric value).
DCLEAR0
DWRITE"HIT F4"
VAR3=DREADF
IF (DKEY=24)
DCLEAR2
DWRITE"TRY AGAIN"
NIF
26
Gem6K Series Programmer’s Guide
;
;
;
;
;
;
;
;
Clear RP240 display
Send message to RP240 display
Read data from a RP240 function key into
numeric variable 3
Evaluate expression to see if function key F4 was hit
Clear RP240 display line 2
Send message to RP240 display
End of IF
www.comoso.com
RP240 Data Read
Immediate Mode
The DREADI1 command allows continual numeric or function key data entry from the RP240
(when used in conjunction with the DREAD and/or DREADF commands). In this immediate
mode, program execution is not paused (waiting for data entry) when a DREAD or DREADF
command is encountered. Refer to the DREAD and DREADF command descriptions for
programming examples.
NOTES
• While in the Data Read Immediate Mode, data is read into numeric variables only (VAR).
• This feature is not designed to be used in conjunction with the RP240's standard menus;
the RUN, JOG, and DJOG menus will disable the DREADI mode.
• Do not assign the same variable to read numeric data and function key data—pick only one.
Following Conditions
These Following conditions are available for conditional expressions: Axis status bit #26
(AS.26), Error status bit #14 (ER.14), Following status (FS), NMCY, PCME, PCMS, PMAS,
PME, PSHF, PSLV, and VMAS.
Expression
Description
(2AS.26=b1)
True if a new motion profile on axis 2 is waiting for the GOWHEN condition to be
true or a TRGFNc1xxxxxxx trigger.
True if the GOWHEN condition on axis 1 is already true when the subsequent GO,
GOL, FSHFC, or FSHFD command is executed.
True if the master for follower axis 3 is in motion.
True if the master for axis 2 has moved through 200 cycles.
True if the master for axis 1 has traveled more than 12 units.
True if follower axis 1 has shifted more than 1.5 units.
True if follower axis 3's commanded position is more than 24 units.
True if the velocity of the master for axis 1 is less than 2 units/sec.
(1ER.14=b1)
(3FS.7=b0)
(2NMCY>200)
(1PMAS>12)
(1PSHF>1.5)
(3PSLV>24)
(1VMAS<2)
Multi-Tasking
Conditions
Conditional Looping
These Multi-tasking conditions are available for conditional expressions: Status of which tasks
are current active (SWAP), identity of the task in which the command is executed (TASK).
Expression
Description
(SWAP.3=b1)
(TASK=3)
True if Task 3 is active.
True if the task executing the conditional expression is Task 3.
The Gem6K controller supports two conditional looping structures—REPEAT/UNTIL and
WHILE/NWHILE.
All commands between REPEAT and UNTIL are repeated until the expression contained
within the parenthesis of the UNTIL command is true. The example below illustrates how a
typical REPEAT/UNTIL conditional loop works. In this example, the REPEAT loop will
execute 1 time, at which point the expression stated within the UNTIL command will be
evaluated. If the expression is true, command processing will continue with the first
command following the UNTIL command. If the expression is false, the REPEAT loop will
be repeated.
VAR5=0
DEL prog10
DEF prog10
INFNC1-A
INFNC2-A
INFNC3-A
INFNC4-A
OUTFNC1-A
A50
AD50
V5
D25000
REPEAT
GO1
VAR5=VAR5+1
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
Initializes variable 5 to 0
Delete a program before defining it
Defines program prog10
Assign onboard input 1 as g.p. input for use
Assign onboard input 2 as g.p. input for use
Assign onboard input 3 as g.p. input for use
Assign onboard input 4 as g.p. input for use
Assign onboard output 1 is a general-purpose
Acceleration is 50
Deceleration is 50
Sets velocity to 5
Distance is 25,000
Begins the REPEAT loop
Executes the move (Go)
Variable 5 counts up from 0
with IN
with IN
with IN
with IN
output
Chapter 1. Programming Fundamentals
27
www.comoso.com
UNTIL(IN=b1110 OR VAR5>10) ; When inputs 1-4 are 1110, respectively, or
; VAR5 is greater than 10, the loop will stop.
OUT1
; Turn on output 1 when finished with REPEAT loop
END
; End program definition
RUN prog10
; Initiate program prog10
All commands between WHILE and NWHILE are repeated as long as the WHILE condition is
true. The following example illustrates how a typical WHILE/NWHILE conditional loop
works. In this example, the WHILE loop will execute if the expression is true. If the
expression is false, the WHILE loop will not execute.
VAR5=0
; Initializes variable 5 to 0
DEL prog10
; Delete a program before defining it
DEF prog10
; Defines program prog10
INFNC1-A
; Assign onboard input 1 as g.p. input for use with IN
INFNC2-A
; Assign onboard input 2 as g.p. input for use with IN
INFNC3-A
; Assign onboard input 3 as g.p. input for use with IN
INFNC4-A
; Assign onboard input 4 as g.p. input for use with IN
OUTFNC1-A
; Assign onboard output 1 is a general-purpose output
A50
; Acceleration is 50
AD50
; Deceleration is 50
V5
; Sets velocity to 5
D25000
; Distance is 25,000
WHILE(IN=b1110 OR VAR5>10) ; While the inputs 1-4 are 1110, respectively
; or VAR5 is greater than 10, the loop will continue.
GO1
; Executes the move (Go)
VAR5=VAR5+1
; Variable 5 counts up from 0
NWHILE
; End WHILE command
OUT1
; Turn on output 1 when finished with WHILE loop
END
; End program definition
; *****************************************************
; * To run prog10, execute the "RUN prog10" command
*
; *****************************************************
Conditional
Branching
You can use the IF command for conditional branching. All commands between IF and
ELSE are executed if the expression contained within the parentheses of the IF command is
true. If the expression is false, the commands between ELSE and NIF are executed. If the
ELSE is not needed, it may be omitted. The commands between IF and NIF are executed if
the expression is true. Examples of these commands are as follows.
DEL prog10
DEF prog10
INFNC1-A
INFNC2-A
INFNC3-A
INFNC4-A
A50
AD50
V5
IF(VAR1>0)
D25000
ELSE
D50000
NIF
IF(IN=b1110)
GO1
NIF
END
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
Delete a program before defining it
Defines program prog10
Assign onboard input 1 as g.p. input for
Assign onboard input 2 as g.p. input for
Assign onboard input 3 as g.p. input for
Assign onboard input 4 as g.p. input for
Acceleration is 50
Deceleration is 50
Sets velocity to 5
IF variable 1 is greater than zero
Distance is 25,000
Else
Distance is 50,000
End if command
If onboard inputs 1-4 are 1110, initiate
Executes the move (Go)
End IF command
End program definition
; *****************************************************
; * To run prog10, execute the "RUN prog10" command
*
; *****************************************************
28
Gem6K Series Programmer’s Guide
use
use
use
use
with
with
with
with
IN
IN
IN
IN
axis 1 move
www.comoso.com
Program Interrupts (ON Conditions)
Multi-Tasking
Each task has its own
ONP program and its
own set of ON
conditions.
While executing a program, the Gem6K controller can interrupt the program based on several
possible ON conditions: programmable input(s) status, user status, or the value of numeric
variables #1 or #2. These ON conditions are enabled with the ONCOND command, and are
defined with the commands listed below. After the ON conditions are enabled (with the
ONCOND command), an ON condition interrupt can occur at any point in program execution.
When an ON condition occurs, the controller performs a GOSUB to the program assigned as
the ON program and then passes control back to the original program and resumes command
execution at the command line from which the interruption occurred.
Within the ON program, the programmer is responsible for checking which ON condition
caused the branch (if multiple ON conditions are enabled with the ONCOND command).
Once a branch to the ON program occurs, the ON program will not be called again until after
it has finished executing. After returning from the ON program, the condition that caused the
branch must evaluate false before another branch to the ON program will be allowed.
SETUP FOR PROGRAM INTERRUPT (see programming example below)
1. Define a program to be used as the ON program to which the controller will GOSUB
when an ON condition evaluates true.
2. Use the ONP command to assign the program as the ON program.
3. Use the ONCOND command to enable the ON conditions that you are using. The syntax
for the ONCOND command is ONCOND<b><b><b><b>, where the first <b> is for the ONIN
condition, the second for ONUS, the third for ONVARA, and the fourth for ONVARB.
ON conditions:
ONIN
ONUS
ONVARA
ONVARB
Specify an input bit pattern that will cause a GOSUB to the program
assigned as the ON program (see programming example below).
Specify an user status bit pattern that will cause a GOSUB to the ON
program. The user status bits are defined with the INDUST command.
Specify the range of numeric variable #1 (VAR1) that will cause a GOSUB
to the ON program. For example, ONVARAØ,2Ø establishes the condition
that if the value of VAR1 is ≤0 or ≥20, the ON program will be called.
This is the same function as ONVARA, but for numeric variable #2 (VAR2)
Programming Example: Configures the controller to increment variable #1 when input #1 goes active.
If input #1 does go active, control will be passed (GOSUB) to the ON program (onjump), the commands
within the ON program will be executed, and control will then be passed back to the original program.
Situations in which ON
conditions WILL NOT
interrupt immediately
DEF onjump
VAR1=VAR1+1
END
; Begin definition of program onjump
; Increment variable 1
; End definition of program onjump
VAR1=0
ONIN1
ONP onjump
ONCOND1000
;
;
;
;
;
Initialize variable 1
When input 1 becomes active, branch to the ON program
Assign the onjump program as the ON program
Enable only the ONIN function. Disable the ONUS,
ONVARA, and ONVARB functions, respectively
These are situations in which an ON condition does not immediately interrupt the program in
progress. However, the fact that the ON condition evaluated true is retained, and when the
condition listed below is no longer preventing the interrupt, the interrupt will occur.
• While motion is in progress due to GO, GOL, GOWHEN, HOM, JOY, JOG, or PRUN and the
continuous command execution mode is disabled (COMEXCØ).
• While a WAIT statement is in progress
• While a time delay (T) is in progress
• While a program is being defined (DEF)
• While a pause (PS) is in progress
• While a data read (DREAD, DREADI, DREADF, or READ) is in progress
Chapter 1. Programming Fundamentals
29
www.comoso.com
Error Handling
The Gem6K Series products have the ability to detect and recover the following error conditions:
Wizards can help:
Motion Planner’s Wizard
Editor provides an Error
Program wizard that
creates an Error program,
provides safeguards for
preventing unwanted calls
to the Error program, and
includes conditional code
to handle the errors you
wish to check.
DEBUG TOOLS
For information on
program debug tools,
refer to page 221.
Error bit 1* ........ Stall Detected: Functions when stall detection has been enabled (ESTALL or DSTALL)
and ESK1 is set.
Error bit 2 .......... Hard Limit Hit: Functions when hard limits are enabled (LH).
Error bit 3 .......... Soft Limit Hit: Functions when soft limits are enabled (LS).
Error bit 4 .......... Drive Fault: Detected only if the drive is enabled (DRIVE1).
Error bit 5 .......... Command Kill or Commanded Stop: K, !K,<ctrl>K, S, or !S command sent.
Error bit 6 .......... Kill Input: When an input is defined as a Kill input (INFNCi-C) and that input
becomes active.
Error bit 7 .......... User Fault Input: When an input is defined as a User fault input (INFNCi-F) and that
input becomes active.
Error bit 8 .......... Stop Input: When an input is defined as a Stop input (INFNCi-D) and that input
becomes active.
Error bit 9 .......... Enable Input is activated (not grounded).
Error bit 10 ........ Pre-emptive (on-the-fly) GO or a registration move not possible
Error bit 11** .... Target zone settling timeout period (set with the STRGTT command) is exceeded.
Error bit 12** .... Maximum position error (set with the SMPER command) is exceeded.
Error bit 13 ........ RESERVED.
Error bit 14 ........ GOWHEN condition already true when GO, FSHFC, or FSHFD was executed
Error bit 15 ........ RESERVED.
Error bit 16 ........ Bad command detected (bit is cleared with TCMDER command).
Error bit 17 ........ RESERVED.
Error bit 18 ........ Cable to expansion I/O brick is disconnected or power to the I/O brick is lost; error is
cleared by reconnecting to I/O brick and issuing the ERROR.18-0 command and then
the ERROR.18-1 command. (Multi-tasking: this condition also kills all tasks.)
Error bits 19-22 . RESERVED.
Error bit 23 ........ Error bit 20
RESERVED.
Error bit 23 ........ Ethernet Client connection error.
Error bit 24 ........ Error bit 24
Ethernet Client polling error.
Error bit 25-32... RESERVED.
* Steppers only
** Servos only
30
Gem6K Series Programmer’s Guide
www.comoso.com
Enabling Error Checking
To detect and respond to the error conditions noted above, the corresponding error-checking
bit(s) must be enabled with the ERROR command (refer to the ERROR Bit # column in the
table below). If an error condition occurs and the associated error-checking bit has been
enabled with the ERROR command, the Gem6K controller will branch to the error program.
For example, if you wish the Gem6K controller to branch to the error program when a
hardware end-of-travel limit is encountered (error bit #2) or when a drive fault occurs (error
bit #4), you would issue the ERRORØ1Ø1 command to enable error-checking bits #2 and #4.
MULTI-TASKING
If you are operating multiple tasks, be aware that you must enable error conditions (ERROR) and
specify an error program (ERRORP) for each task (e.g., 2%ERROR.2-1 and 2%ERRORP FIX for
Task 2). Each task has its own error status register (reported with ER, TER, and TERF).
Regarding axis-related error conditions (e.g., drive fault, end-of-travel limit, etc.), only errors on
the task’s associated (TSKAX) axes will cause a branch to the task’s ERRORP program.
☞ Helpful Hint: Within the structure of your error program, you can use the IF and ER
commands to check which error caused the call to the ERRORP program
and respond accordingly.
Defining the Error Program
The purpose of the error program is to provide a programmed response to certain error
conditions (see list above) that may occur during the operation of your system. Programmed
responses typically include actions such as shutting down the drive(s), activating or deactivating outputs, etc. Refer to the error program set-up example below.
Using the ERRORP command, you can assign any previously defined program as the error
program. For example, to assign a previously defined program named CRASH as the error
program, enter the ERRORP CRASH command. To un-assign a program from being the error
program, issue the ERRORP CLR command (e.g., as in this example, it does not delete the
CRASH program, but merely unlinks it from its assignment as the error program).
Chapter 1. Programming Fundamentals
31
www.comoso.com
Canceling the Branch to the Error Program
NOTE: In addition to
canceling the branch to
the error program, you
must also remedy the
cause of the error;
otherwise, the error
program will be called
again when you resume
operation. Refer to the
How to Remedy the
Error column in the table
below for details.
ERROR
Bit #
If an error condition occurs and the associated error-checking bit has been enabled with the
ERROR command, the Gem6K controller will branch to the error program. The error program
will be continuously called/repeated until you cancel the branch to the error program. (This is
true for all cases except error condition #9, ENABLE input activated, in which case the error
program is called only once.)
There are three options for canceling the branch to the error program:
• Disable the error-checking bit with the ERROR.n-Ø command, where "n" is the
number of the error-checking bit you wish to disable. For example, to disable error
checking for the kill input activation (bit #6), issue the ERROR.6-Ø command. To reenable the error-checking bit, issue the ERROR.n-1 command.
• Delete the program assigned as the ERRORP program (DEL <name of program>).
• Satisfy the How to Remedy the Error requirement identified in the table below.
Cause of the Error
How to Remedy the Error
Issue a GO command.
1
Steppers only: Stall detected (Stall Detection and
Kill On Stall must be enabled first—see ESTALL
and ESK, respectively).
Gosub
2
Hard Limit Hit.
(hard limits must be enabled first—see LH)
If COMEXLØ, then Goto;
Change direction & issue GO command on the axis
If COMEXL1, then Gosub that hit the limit; or issue LHØ.
3
Soft Limit Hit.
(soft limits must be enabled first—see LS)
If COMEXLØ, then Goto;
Change direction & issue GO command on the axis
If COMEXL1, then Gosub that hit the limit; or issue LSØ.
4
Drive Fault (Detected only if you enable drive,
DRIVE1, and drive fault input, DRFEN.)
Goto
Clear the fault condition at the drive, & issue a
DRIVE1 command for the faulted axis.
5
Commanded Stop or Kill (whenever a K, !K,
<ctrl>K, K, or !S command is sent).
If !K, then Goto;
If !S & COMEXSØ, then
Goto;
If !S & COMEXS1, then
Gosub, but need !C
No fault condition is present—there is no error to
clear.
See note below entitled
“Commanded Kill or Stop”.
32
Branch Type to Error
Program
If you want the program to stop, you must issue
the !HALT command.
6
Kill Input Activated (see INFNCi-C or LIMFNCi-C) Goto
Deactivate the kill input.
7
User Fault Input Activated
(see INFNCi-F or LIMFNCi-F).
Goto
Deactivate the user fault input, or disable it by
assigning it a different function (INFNC or
LIMFNC).
8
Stop input activated
(see INFNCi-D or LIMFNCi-C).
Goto
Deactivate the stop input, or disable it by assigning
it a different function.
9
ENABLE input not grounded. (see “ESTOP” below)
Goto
Re-ground ENABLE input, and issue @DRIVE1.
10
Profile for pre-emptive GO or registration move not
possible at the time of attempted execution.
Gosub
Issue another GO command.
11
Servos only: Target Zone Timeout (STRGTT value Gosub
has been exceeded).
Gem6K Series Programmer’s Guide
Issue these commands in this order:
STRGTEØ, DØ, GO, STRGTE1
www.comoso.com
12
Servos only: Exceeded Max. Allowable Position
Error (set with the SMPER command).
Gosub
Issue a DRIVE1 command to the axis that
exceeded the allowable position error. Verify that
feedback device is working properly.
14
GOWHEN condition was already true when the
subsequent GO, GOL, FGADV, FSHFC, or FSHFD
command was executed.
Goto
Issue another GOWHEN command; or issue a !K
command and check the program logic (use the
TRACE and STEP features if necessary).
16
Bad command was detected.
Gosub
Issue the TCMDER command to I.D. the command.
17
Encoder failure detected (EFAIL1 must be
enabled before this error can be detected).
Gosub
Reconnect the encoder while the axis is in the
EFAIL1 mode.
18
Cable to an expansion I/O brick is disconnected,
or power to the I/O brick is lost.
Goto
Reconnect I/O brick cable. Issue the ERROR.18-0
command and then the ERROR.18-1 command.
23
Ethernet Client connection error. See the Ethernet
Client section for additional details.
Gosub
24
Ethernet Client polling error. See the Ethernet
Client section for additional details.
Gosub
Reserved Bits: Bits 13, 15, 19-22 and 25-32.
Branching Types: If the error condition calls for a GOSUB, then after the ERRORP program is executed, program control returns to the point
at which the error occurred. To prevent a return to the point at which the error occurred, use the HALT command to end program execution or
use the GOTO command to go to a different program. If the error condition calls for a GOTO, there is no way to return to the point at which the
error occurred.
Commanded Kill or Stop: When ERROR bit 5 is enabled (ERROR.5-1), a Stop (S or !S) or a Kill (K, !K or <ctrl>K) command will cause the
controller to branch to the error program. Note, however, that this error condition does not set an error bit (ER), because there is no way to
clear the error condition upon leaving the error program. Therefore, you should use the IF(ER=b00000000000000000000000000000000)
statement in your error program to determine if the cause of the error was a commanded kill or stop (i.e., if no error bits are set).
If ESTOP (ENABLE input) also cuts power to drives: This note is for systems in which power to the drives (not the Gem6K) is cut if the
ENABLE input is opened. If you enable ERROR bit #9: When the ENABLE input is opened (and power is cut to the drives), the ERRORP
program is called. Because the drives have lost power, the Gem6K will detect drive faults, which in turn kills the ERRORP program. If the
ENABLE input is still ungrounded, the ERRORP program will again be called and then killed because of the drive fault condition (causing an
endless loop). The resolution is to place the @DRFEN0 command in the ERRORP program so that it can disable checking the drive fault input
and thereby circumvent the endless loop of calling the ERRORP program. Be sure to later re-enable drive fault checking with @DRFEN1 after the
ENABLE input is re-grounded.
Chapter 1. Programming Fundamentals
33
www.comoso.com
Error Program Set-up Example
The following is an example of how to set up an error program. This particular example is for
handling the occurrence of a user fault.
Step 1
Create a program file (in Motion Planner’s Editor module) to set up the error program:
;
;
;
;
;
;
********************************************************************
* Assign the user fault input function to onboard trigger input 1. *
* The purpose of the user fault input is to detect the occurrence *
* of a fault external to the Gem6K controller and the motor/drive. *
* This input will generate an error condition.
*
********************************************************************
INFNC1-F
;
;
;
;
;
;
; Define onboard trigger input #1 as a user fault input
********************************************************************
* Define a program to respond to the user fault (call the program *
* fault), and then assign that program as the error program. The
*
* purpose of the fault program is to display a message to inform
*
* the operator that the user fault input has been activated.
*
********************************************************************
DEL fault
DEF fault
IF(ER.7=b1)
; Delete a program before defining it (a precaution)
; Begin definition of program fault
; Check if error bit 7 equals 1
; (which means the user fault input has been activated)
WRITE"FAULT INPUT\10\13"
; Send the message FAULT INPUT
T3
; Wait 3 seconds
NIF
; End IF command
END
; End definition of program fault
ERRORP fault ; Assign the program called fault as the error program
; ********************************************************************
; * Enable the user fault error-checking bit by putting a “1” in
*
; * the seventh bit of the ERROR command. After enabling this
*
; * error-checking bit, the controller will branch to the error
*
; * program whenever the user fault input is activated.
*
; ********************************************************************
ERROR0000001 ; Branch to error program upon user fault input (As an
; alternative to the ERROR0000001 command, you could also
; enable bit #7 by issuing the ERROR.7-1 command.)
Step 2
Save the program file in the Editor module. Then, using the Terminal module, download the
program file to the Gem6K controller.
Step 3
Test the error handling:
1.
While in the terminal emulator, enter these four commands:
L
WRITE"IN LOOP\10\13"
T2
LN
34
;
;
;
;
;
Loop command
Display the message "IN LOOP"
Wait 2 seconds
End the loop ("IN LOOP" will be displayed
once every 2 seconds)
2.
While the loop (IN LOOP) is executing in the terminal emulator, enter the !INEN1
command. The !INEN1 command disables input #1 and forces it on for testing
purposes. This simulates the physical activation of input #1. (Since the error program is
called continuously until the branch to the error program is canceled, the message FAULT
INPUT will be repeatedly displayed once every 3 seconds.)
3.
While the FAULT INPUT loop is executing in the terminal emulator, enter the !INENE
command. The !INENE command re-enables input #1. The message IN LOOP will not
be displayed again, because the user fault input error is a GOTO branch (not a GOSUB
branch) to the error program.
Gem6K Series Programmer’s Guide
www.comoso.com
Non-Volatile Memory
The items listed below are automatically stored in the Gem6K product’s non-volatile memory
(battery-backed RAM). Cycling power or issuing a RESET command will not affect these
settings.
• Power-up program (STARTP)
• Programs (defined with DEF & END)
• Compiled profiles and PLC programs (PCOMP). Compiled profiles and PLC programs are
always saved in the Compiled portion of battery-backed RAM. However, compiled
individual axis profiles (GOBUF profiles) are removed from Compiled memory if you run
them with the PRUN command and later cycle power or reset the controller (you will
have to re-compile them with the PCOMP command).
• Memory allocation (MEMORY)
• Axis type definition (AXSDEF)
• Variables: VAR, VARI, VARB, and VARS
• Scaling: SCALE, SCLA, SCLD, SCLV, SCLMAS
• Commanded direction polarity (CMDDIR)
• Encoder polarity (ENCPOL)
• Device address for RS-232 or RS-485 serial communication (ADDR)
• Baud rate for RS-232 or RS-485 serial communication (BAUD)
• Ethernet IP address (NTADDR
• Ethernet network mask (NTMASK)
• RP240 check and serial port functionality (DRPCHK)
• RP240 password (DPASS)
• Servo gain sets (SGSET)
A checksum is calculated for the non-volatile memory area each time you power up or reset
your Gem6K controller. A bad checksum indicates that the user memory has been corrupted
(possibly due to electrical noise) or has been cleared (due to a spent battery). The controller
will clear all user memory when a bad checksum is calculated on power up or reset, and bit 22
will be set in the TSS command response.
System Performance
Several commands (listed below), when enabled, will slow command processing. This
degradation in performance will not be noticeable for most applications. But for some, it may
be necessary to disable one or all of these commands.
•
•
•
•
•
•
SCALE (enable/disable scaling)
INDUSE (enable/disable user status updates)
INFNC (trigger and extended input functions; excluding functions “A” and “H”)
LIMFNC (limit input functions; excluding functions “A”, “R”, “S”, and “T”)
OUTFNC (digital output functions; excluding function “A”)
ONCOND (enable/disable ON conditions)
Chapter 1. Programming Fundamentals
35
www.comoso.com
www.comoso.com
Communication
2
CHAPTER TWO
Communication
IN THIS CHAPTER
•
•
•
•
•
Communication options (protocols, connections)........................................................ 38
Motion Planner™ communication features ................................................................. 38
Ethernet Networking Overview: ................................................................................. 39
− Networking Guidelines.......................................................................................... 56
− Configuring the Gem6K for Ethernet Communications ........................................ 57
− Networking with other 6K or Gem6K Products (peer-to-peer) ............................. 56
− Networking with a DVT Vision System................................................................ 57
− Networking with an Allen-Bradley SLC 5/05 PLC ............................................... 56
− Networking with OPTO22 SNAP I/O ................................................................... 56
Ethernet Client operation ............................................................................................. 39
Serial Communication:
− Controlling multiple serial ports............................................................................ 56
− RS-232C daisy-chaining........................................................................................ 57
− RS-485 multi-drop................................................................................................. 60
www.comoso.com
Communication Options
GV6K
RS-232/485
RS-232
Gemini
Servo
24V RTN
RELAY COM
RELAY N.O.
RS-232/485 (COM1)
RS-232 (COM2)
Expansion I/O
+24VDC Power Input
SERVO
MOTOR
D
2
RE 4V R
T
LA
RE Y C
LA O
Y
N.O
AC Power
Motor Feedback
DRIVE I/O
ETHERNET
VBUS+
EXPANSION I/O
W
m
Se ini
rv
o
4V
Motor Power
I/O Connections
Ethernet
V
DRIVE I/O
Master Encoder
MASTER ENCODER
MASTER ENCODER
L1
MOTOR FEEDBACK
L2/N
MOTOR FEEDBACK
VBUS–
ETHERNET
WARNING: Hazardous voltage may exist for up to
30 seconds after power is removed.
U
GV
6
Ge K
+2
RS-232
Relay
COMPUMOTOR
RS-232/485
EXPANSION I/O
+24V DC
GV-U3/6/12
COM1 Port (RS-232/485)
Set up for use as the primary RS-232 or RS-485 port. Configurable for the RP240
(requires external +5VDC supply)
COM2 Port (RS-232)
Set up for use as an additional RS-232 port. Configurable for the RP240. Operating
system upgrades via this port only.
Ethernet Port
Refer to the configuration procedures that follow.
Using multiple ports
You can communicate to either the Ethernet port or COM1 at any given time. Enabling
the Ethernet port (NTFEN1) will disable COM1. COM2 is always enabled for use as
RS232 or with an RP240.
Motion Planner Communication Features
Motion Planner provides easy direct communication links to the product:
• Communicate directly from any Motion Planner utility (Wizard Editor, Program Editor,
Terminal Emulator, and Panels).
• Communication setup parameters (Ethernet and serial communication).
• Download the Gem6K product’s soft operating system. The operating system is loaded
at the factory, but may use this feature to download upgrades.
• Download motion programs to the controller, and upload motion programs from the
controller.
Communications Server: Also available on the Motion Planner CD is a 32-bit OLE
automation server for adding Gem6K communication capability to your custom applications
created with programming languages such as Visual Basic or Visual C++. For details, refer to
the COM6SRVR Programmer’s Guide or to the Motion Planner Help System.
38
Gem6K Series Programmer’s Guide
www.comoso.com
Ethernet Networking
Overview
The Gem6K is equipped for Ethernet communication. It includes 10Base-T (10Mbps twisted
pair); TCP/IP protocol. RJ-45 connector. Default IP address is 192.168.10.30. You have these
options for networking the Gem6K over Ethernet:
Setup Wizard Available
The Motion Planner
Wizard Editor provides a
setup wizard, called
“Network”, to help you
establish 6K Client/Server
communication (up to six
servers).
• Gem6K as a client. You can connect the Gem6K via Ethernet to multiple devices,
creating a client/server network. The Gem6K is the client, and has the ability to open or
close a connection with another device (server) and request information from that
device. The Gem6K supports up to 6 simultaneous server connections. Devices (servers)
that may be connected to the Gem6K include:
− Allen Bradley SLC5-05 PLC (see page 51 for setup procedures)
− OPTO22 SNAP I/O, using Modbus/TCP protocol (see page 48 for setup
procedures)
− DVT vision system cameras (see page 50 for setup procedures)
EXAMPLE — Closed Network:
Ethernet Switch
Ethernet Switch
(255.255.255.0)
out
(255.255.0.0)
out
Connection to
company network
6K
Client (Server to PC)
IP = 192.168.10.30
Ethernet
Card
Device 2
Ethernet
Card
Server
IP = 192.168.10.80
Device 1
PC
Server
IP = 192.168.10.120
Client
IP = 192.168.10.31
IP = 172.20.44.180
EXAMPLE — Direct Connect to One Server:
Crossover Cable
provided in 6K ship kit
(p/n 71-017635-01)
Serial Cable
Device
6K
PC
Chapter 2. Communication
39
www.comoso.com
• Gem6K as a server. The Gem6K waits for a PC to establish a connection with it and then
provides information on a continual or requested basis. The PC communicates with the
Gem6K through the use of the COM6SRVR Communications Server, which is what
Motion Planner uses to communicate with the Gem6K (for details, refer to the
COM6SRVR Communications Server Programmer’s Reference—see
www.compumotor.com for this document). The Gem6K does not support simultaneous
connections with multiple clients (PCs).
EXAMPLE — Closed Network:
Switch or Hub
Switch or Hub
(255.255.255.0)
(255.255.0.0)
Connection to
company network
Ethernet
Card
6K
Ethernet
Card
Server
IP = 192.168.10.30
PC
Client
IP = 192.168.10.31
IP = 172.20.44.180
EXAMPLE — Direct Connect to PC:
Crossover Cable
provided in 6K ship kit
(p/n 71-017635-01)
Switch or Hub
(255.255.0.0)
Connection to
company network
6K
Ethernet
Card
Ethernet
Card
Server
IP = 172.20.34.30
PC
Client
IP = 172.20.34.160
40
Gem6K Series Programmer’s Guide
IP = 172.20.44.180
www.comoso.com
• Combination of server and client. For example, the Gem6K could be the client for an
OPTO22 (server) and an Allen-Bradley PLC (server). At the same time, a software
program running on a PC could be using the Gem6K as a server.
Ethernet Switch
Ethernet Switch
(255.255.255.0)
out
(255.255.0.0)
out
Connection to
company network
6K
Client (Server to PC)
IP = 192.168.10.30
Ethernet
Card
Device 2
Ethernet
Card
Server
IP = 192.168.10.80
Device 1
PC
Server
IP = 192.168.10.120
Client
IP = 192.168.10.31
Setup Wizard Available
The Motion Planner
Wizard Editor provides a
setup wizard, called
“Network”, to help you
establish 6K peer-to-peer
communication.
IP = 172.20.44.180
• Peer-to-peer network with other 6K or Gem6K units. The 6K may be connected to
other 6K devices (6K Controllers or Gem6K drive/controllers) via Ethernet. Up to eight
6K devices may be networked in this manner. This type of connection uses UDP
broadcasting and is not a client/server relationship. (see page 46 for setup procedures)
Ethernet Switch
Ethernet Switch
(255.255.255.0)
out
(255.255.0.0)
out
6K unit 1
Connection to
company network
IP = 192.168.10.30
Ethernet
Card
6K unit 2
Ethernet
Card
IP = 192.168.10.40
PC
IP = 192.168.10.31
IP = 172.20.44.180
Chapter 2. Communication
41
www.comoso.com
Networking Guidelines
• Use a closed network. Because of network broadcasts, it is best to put the Gem6K,
along with any associated server devices, on a closed network with its own subnet. If
you have a PC connected to the Ethernet Client/Server network and the PC is also
connect to your company’s network, use one Ethernet card for the Ethernet
Client/Server network and another Ethernet card for the company network (refer to the
example below) .
Ethernet Switch
Ethernet Switch
(255.255.255.0)
out
(255.255.0.0)
out
6K
Client (Server to PC)
IP = 192.168.10.30
Device 2
Device 1
Ethernet
Card
Ethernet
Card
Server
IP = 192.168.10.80
PC
Server
IP = 192.168.10.120
Client
IP = 192.168.10.31
IP = 172.20.44.180
• If the Gem6K is placed on an open network, put the Gem6K and any associated server
devices on one side of a Ethernet network switch with its own subnet and install a
bridge to filter traffic, such that broadcast traffic does not pass in either direction (see
diagram below). This will prevent the Gem6K from broadcasting to the entire network.
Ethernet Switch
Ethernet Switch
(255.255.255.0)
out
(255.255.0.0)
out
Bridge
6K
Device 2
Client
IP = 192.168.10.30
Server
IP = 192.168.10.80
IP = 172.20.44.180
Ethernet
Card
Device 1
Server
IP = 192.168.10.120
PC
• A switch (recommended) or hub must be used if you are making more than one
Ethernet connection with the Gem6K.
• The Gem6K client must have the same subnet address as all of the server devices it will
connect to (PLC, OPTO22, DVT, etc.). For example, if the subnet mask (NTMASK) is
255.255.255.0, and the subnet address is 192.168.10.*, then all devices (including the
Gem6K) must have an address starting with 192.168.10.*, where the * number is
unique to the device.
• Fieldbus (DeviceNet or Profibus) versions of the Gem6K (part numbers Gem6Kn-DN
or Gem6Kn-PB) cannot also communicate as an Ethernet Client at the same time. If
you have a Fieldbus unit and need to use Ethernet instead, execute the OPTENØ
42
Gem6K Series Programmer’s Guide
www.comoso.com
command, then the RESET command (this disables the Fieldbus features), and then the
NTFEN1 or NTFEN2 command. To re-enable Fieldbus communication, execute the
NTFENØ command, then the RESET command (this disables Ethernet communication),
and then the OPTEN1 command.
• You cannot communicate to the Gem6K with simultaneous transmissions over both the
“ETHERNET” and “RS-232” (PORT1) connections.
• Follow the manufacturer’s setup procedure for each Allen-Bradley PLC, DVT camera
and OPTO22 Ethernet I/O rack.
• You should be able to ping every Gem6K, DVT camera, PLC and OPTO22 I/O rack
from the PC. Use the ping command at the DOS prompt:
ping 192.168.10.30
(space)
Device’s IP Address
If your PC responds with “Request Timed Out”,
check your Ethernet wiring and IP address setting.
• The following Ethernet setup commands need only be sent once to the Gem6K,
because they are saved in non-volatile memory and are remembered on power-up and
RESET: NTID, NTIO, NTIP, NTMPRB, NTMPRI, NTMPWB, and NTMPWI.
• If a PC is connected to the Gem6K/Device Ethernet network, then the PC should
include all devices in a static mapping table. The static mapping procedure, for the
Gem6K’s address, is found on page 44.
• If the Gem6K is in a peer-to-peer network, enable Ethernet communication with the
NTFEN1 command (NTFEN2 mode is not compatible with peer-to-peer communication).
Configuring the Gem6K for Ethernet Communication
PC-to-Gem6K
Communication over
RS-232 Only
PC-to-Gem6K
Communication over
Ethernet
If your PC will be communicating to the Gem6K over RS-232 (not Ethernet), follow this
procedure:
1.
Connect the Gem6K controller to your network (refer to Networking Guidelines on page
42).
2.
Establish an RS-232 communication link between the Gem6K and your computer (connect to
the Gem6K’s “RS-232” connector according to the instructions in the Gem6K Installation
Guide).
3.
Install Motion Planner on your computer, and launch Motion Planner. Click on the Terminal
tab to view the terminal emulator.
4.
button to view the Communications Settings dialog.
In the Terminal window, click on the
Select the Port tab and select the COM port that is connected to the Gem6K’s “RS-232”
connector (see Step 2 above). Click OK.
5.
In the Terminal window, enable Ethernet communication with the appropriate NTFEN
command:
a. If you are using the Gem6K as a server or client, type the NTFEN2 command and press
ENTER, then type the RESET command and press ENTER.
b. If you are using the 6K in a peer-to-peer connection with another 6K or Gem6K, type the
NTFEN1 command and press ENTER, then type the RESET command and press ENTER.
If your PC will be communicating to the Gem6K over Ethernet, follow this procedure:
1.
Connect the Gem6K controller to your network (refer to Networking Guidelines on page
42).
Chapter 2. Communication
43
www.comoso.com
Changing the Gem6K’s
IP Address or Subnet
Mask
2.
Install your Ethernet card and configure it for TCP/IP protocol. Refer to your Ethernet card’s
user documentation for instructions. (If you need to change the 6K’s IP address or subnet mask,
refer to the note on the left.)
The factory default Gem6K
IP address is
192.168.10.30; the default
mask is 255.255.255.0.
3.
(see illustration below) Configure your Ethernet card’s TCP/IP properties so that your
computer can communicate with the 6K controller.
a. Access the Control Panels directory.
b. Open the Network control panel.
c. In the Network control dialog, select the Configuration tab (95/98) or the Protocols tab
(NT) and double-click the TCP/IP network item to view the TCP/IP Properties dialog.
d. In the TCP/IP Properties dialog, select the IP Address tab, select “Specify an IP Address”,
type in 192.168.10.31 in the “IP Address” field, and type in 255.255.255.0 in the “Subnet
Mask” field.
e. Click the OK buttons in both dialogs to finish setting up your computer’s IP address.
If the default address and
mask are not compatible
with your network, you
may change them with the
NTADDR and NTMASK
commands, respectively
(see Gem6K Series
Command Reference for
details on the NTADDR and
NTMASK commands). To
ascertain the Gem6K’s
Mac address, use the
TNTMAC command. The
NTADDR, NTMASK and
TNTMAC commands may
be sent to the 6K controller
over an RS-232 interface
(see Steps 4-6). NOTE: If
you change the 6K’s IP
address or mask, the
changes will not take affect
until you cycle power or
issue a RESET command.
If you are using
Windows NT, select
the “Protocols” tab.
Make sure this number is different
from the one in the 6K’s IP address.
If the 6K’s default IP address is
unchanged (192.168.10.30), then
select a number other than 30.
NOTE
If you are using a computer (Ethernet card) that is
normally connected to a network, you should write
down the existing IP Address and Subnet Mask
values, so that you may restore them later.
3.
Establish an RS-232 communication link between the Gem6K and your computer (connect to
the Gem6K’s “RS-232” connector according to the instructions in the Gem6K Installation
Guide).
4.
Install Motion Planner on your computer, and launch Motion Planner. Click on the Terminal
tab to view the terminal emulator.
5.
In the Terminal window, click on the
button to view the Communications Settings dialog.
Select the Port tab and select the COM port that is connected to the Gem6K’s “RS-232”
connector (see Step 4 above). Click OK.
6.
In the Terminal window, enable Ethernet communication with the appropriate NTFEN
command:
a. If you are using the Gem6K as a server or client, type the NTFEN2 command and press
ENTER, then type the RESET command and press ENTER.
b. If you are using the 6K in a peer-to-peer connection with another 6K or Gem6K, type the
NTFEN1 command and press ENTER, then type the RESET command and press ENTER.
7.
Use the following sub-procedure to statically map the Gem6K’s Ethernet MAC address to
IP address of the Ethernet card in your PC. Static mapping eliminates the need for the PC
44
Gem6K Series Programmer’s Guide
www.comoso.com
to ARP the Gem6K controller, thereby reducing communication overhead.
a. In Motion Planner’s Terminal window, type TNT and press ENTER. The response
includes the Gem6K IP address, and the Gem6K Ethernet address value in hex (this is
also known as the “MAC” address). Write down the IP address and the Ethernet
address (hex value) for later use in the procedure below.
b.
Start a DOS window. The typical method to start a DOS window is to select MS-DOS
Prompt from the Start/Programs menu (see illustration below).
c.
At the DOS prompt, type the arp –s command (see example below) and press ENTER.
arp –s 192.168.10.30 0-90-55-0-0-1 192.168.10.31
6K’s IP Address
(from TNT report)
d.
6K’s Ethernet Address
(from TNT report)
Spaces
(press the space bar)
IP Address of Ethernet Card
To verify the mapped addresses, type the arp –a command and press ENTER.
If you receive the response “No ARP Entries Found”:
1) Switch to the Motion Planner Terminal window, type NTFEN2 (or NTFEN1 if using a
peer-to-peer network) and press ENTER, then type RESET and press ENTER.
2) Switch to the DOS window, type the ping command and press ENTER:
ping 192.168.10.30
(space)
6K’s IP Address (from TNT report)
If your PC responds with “Request
Timed Out”, check your Ethernet
wiring and IP address setting.
3) Repeat the arp –s command as instructed above. Use arp –a to verify.
4) Switch to the Motion Planner Terminal window, type NTFEN2 (or NTFEN1 if using a
peer-to-peer network) and press ENTER, then type RESET and press ENTER.
e.
(OPTIONAL) Automate the arp –s static mapping command. This allows your PC
to automatically perform the static mapping when it is booted; otherwise, you will
have to manually perform static mapping every time you boot your PC.
• Windows 95/98: Add the arp –s command to the Autoexec.bat file.
• Windows NT: Create a batch file that contains the arp –s command. Save the file
(name the file “GEM6KARP.BAT”) to the root directory on the C drive. Using
Windows Explorer, locate the Gem6KARP.BAT file, create a shortcut, then cut and
paste the shortcut into the StartUp directory. Windows NT has several StartUp
directories to accommodate various user configurations. We recommend using the
Administrators or All Users locations. For example, you can paste the shortcut into the
WinNt\Profiles\AllUsers\StartMenu\Programs\StartUp directory, allowing all users to
statically map the IP and Mac addresses whenever the PC is booted.
Chapter 2. Communication
45
www.comoso.com
Ethernet Connection Status
LEDs (located on the RJ-45
“ETHERNET” connector):
• Green LED turns on to
indicate the Ethernet
physical connection is OK.
• Yellow LED flashes to
indicate the Gem6K is
transmitting over the
Ethernet interface.
f.
Connect the Gem6K Controller to your computer using a cross-over 10Base-T cable (5-foot
cable provided in ship kit).
g.
In Motion Planner’s Terminal window, click on the
button to view the Communications
Settings dialog. Select the Port tab, select “Network” and type the IP address (192.168.10.30)
in the text field. Click OK.
h.
You may now communicate to the Gem6K controller over the Ethernet interface. Reminder:
You cannot communicate to the Gem6K with simultaneous transmissions over both the
“ETHERNET” and “RS-232” (PORT1) connections.
8.
Connect the Gem6K Controller to your computer using a cross-over 10Base-T cable (5-foot
cable provided in ship kit).
9.
In Motion Planner’s Terminal window, click on the
button to view the Communications
Settings dialog. Select the Port tab, select “Network” and type the IP address (192.168.10.30)
in the text field. Click OK.
10. You may now communicate to the Gem6K controller over the Ethernet interface.
Reminder: You cannot communicate to the Gem6K with simultaneous transmissions over both
the “ETHERNET” and “RS-232” (PORT1) connections.
Ethernet Connection Status LEDs (located on the RJ-45 “ETHERNET” connector):
•
•
Green LED turns on to indicate the Ethernet physical connection is OK.
Yellow LED flashes to indicate the Gem6K is transmitting over the Ethernet interface.
Networking with Other 6K or Gem6K Products (Peer-to-Peer)
This feature is used to communicate information between 6Ks and Gem6Ks over Ethernet.
This is not a client or server; this feature uses UDP broadcasting over the subnet to transfer
data, so no client/server connection is needed.
There can be up to 8 different 6K or Gem6K devices sharing information, with each device
having access to each shared data from the 7 other device. Each device can broadcast 8 pieces
of information by way of “shared output” variables (VARSHO1 through VARSHO8). These
variables can share with other devices the values of its motion attributes, controller status,
variables, etc. (see list below).
A..........Acceleration
NMCY... Master cycle number
SS..........System status
AD........Deceleration
OUT..... Output status
SWAP......Task swap assignment
ANI .....Analog input voltage
PANI... Analog input position
TASK......Task number
ANO .....Analog output voltage
PC ....... Commanded position
TIM........Timer value
AS........Axis status
PCC..... Captured command pos.
TRIG......Trigger interrupt status
ASX .....Extended axis status
PCE..... Captured encoder pos.
US..........User-defined status
D..........Distance
PCME... Captured master enc. pos.
V ............Velocity
DAC .....DAC output value
PE ....... Encoder position
VARI......Integer variable
DKEY ...RP240 keypad value
PER..... Position error
VARB......Binary variable
ER........Error status
PMAS... Position of Master
VEL........Commanded velocity
FB........Feedback device pos.
PME..... Master encoder pos.
VELA......Actual velocity
FS........Following status
PSHF... Net position shift
VMAS......Velocity of the master
IN........Input status
PSLV... Follower pos. command
VARSHI .Shared input variable
INO .....Enable input status
SC ....... Controller status
LIM .....Limit input status
SCAN... PLC scan time
MOV .....Axis moving status
SEG..... Free segment buffers
The type of data can be either binary, as in the AS (axis status) operand, or a 32-bit unscaled
integer, as in PE (encoder position) operand. The data stored in the VARSHO is not scaled.
46
Gem6K Series Programmer’s Guide
www.comoso.com
Each unit will re-broadcast its updated VARSHO data at a rate set with the NTRATE command.
RECOMMENDATION: Set all devices to broadcast at the same NTRATE rate of 50
milliseconds.
Setup
For 6K or Gem6K sending and/or receiving information via the Peer to Peer feature:
1.
Connect the 6K/Gem6K products to the network and configure each 6K/Gem6K for
Ethernet communication according to the procedures on page 43.
2.
Set the broadcasting rate with NTRATE command, preferably the same for each unit.
3.
If the unit is to receive data only (not send) you are finished with the setup for that unit.
If the unit is to send also, complete steps 4 and 5.
4.
Assign a unique unit number (1-8) with the NTID command.
5.
Assign data to the eight broadcast variables with the VARSHO command.
6.
Repeat steps 2-5 for each unit in the peer-to-peer network.
First 6K or Gem6K:
Example
NTID1
VARSHO1 = 1A
VARSHO2 = 1PE
; Assign this unit a peer-to-peer unit number of 1
; Shared variable #1 contains axis 1's acceleration
; Shared variable #2 contains axis 1's encoder
;position
; ******************************************************************
; * Use this space to define shared output variables VARSHO3 – ;VARSHO7. *
; ******************************************************************
VARSHO8 = VARI1 ; Shared variable #8 contains the value of VARI1
NTRATE50
; Set the broadcasting rate to 50 milliseconds
Second 6K or Gem6K:
NTID2
VARSHO1 = 1D
; Assign this unit an ID of 2
; Shared variable #1 contains axis 1's programmed
;distance
VARSHO2 = 3PE
; Shared variable #2 contains axis 3's encoder
position
; ******************************************************************
; * Use this space to define shared output variables VARSHO3 – VARSHO7. *
; ******************************************************************
VARSHO8 = 1ANI.1 ; Shared variable #8 contains the voltage value at
;analog
; input 1 on I/O brick 1
NTRATE50
; Set the broadcasting rate to 50 milliseconds
Third 6K or Gem6K:
NTRATE50
; Set the broadcasting rate to 50 milliseconds
; This third unit will receive data only. Therefore, it does not
;require
; a unit ID number or VARSHO data assignment
Chapter 2. Communication
47
www.comoso.com
Program
Interaction
Each Unit can read the broadcast variables of each other unit with the nVARSHIi command.
The “n” specifies the ID number (NTID) of the unit you want to read from, the “i” is the
VARSHO number of that unit to be read. For example, if you want unit 1 to read unit 2’s
VARSHO8 data, then use 2VARSHI8.
Using the VARSHI command, you can process data from the VARSHO variable of another peerto-peer unit in these ways:
•
Assign the VARSHO data to a VAR (numeric), VARI (integer), or VARB (binary) variable.
For example, the command VARI1=2VARSHI8 assigns the value of VARSHO8 on unit 2
to the VARI1 integer variable.
•
Assign the VARSHO data to a virtual input (IN). For example, 3IN=2VARSHI3 assigns
the binary value of VARSHO3 from unit 2 to virtual input brick 3.
•
Use the VARSHO data in a conditional expression for an IF, WAIT, WHILE, or UNTIL
statement. For example, if VARSHO5 on unit 2 is assigned is assigned the status of
onboard trigger input 3 (VARSHO5=IN.3), then you could use this command to make
unit 1 wait until trigger input 3 on unit 2 was on: WAIT(2VARSHI5=b1).
First 6K or Gem6K (unit 1):
Example
VARI1 = 2VARSHI8; Assign Unit 2's VARSHO8 (which is the voltage
; value at analog input 1 on I/O brick 1) to VARI1.
Second 6K or Gem6K (unit 2):
VARI100 = 1VARSHI2; Assign Unit 1's VARSHO2 (which is the encoder
;position of axis 1) to VARI100.
Third 6K or Gem6K (reading data only):
VARI90 = 1VARSHI1; Assign Unit 1's VARSHO1 (which is the
;acceleration of axis 1) to VARI90.
Networking with OPTO22 SNAP I/O
The Gem6K client can communicate with the OPTO22 SNAP I/O server to read digital and
analog inputs and outputs, and write digital and analog outputs. The Gem6K supports up to
eight modules per OPTO22.
Setup
1.
2.
3.
48
Follow the manufacturer’s setup procedure for the OPTO22 Ethernet I/O rack.
Connect the Gem6K and OPTO22 products in a network and configure the Gem6K for
Ethernet communication according to the procedures on page 43.
Choose a Server Connection Number for this device. The Gem6K can support up to 6
simultaneous server connections. Pick a number (1-6) that has not been used already for
another connection. This will be used to reference the OPTO22 unit from now on.
4.
Enter the IP address of the OPTO22 and specify a 2 for connection type with the NTIP
command. For example, if the OPTO22 is Server #3 and its IP address is 172.20.34.170,
then the command would be 3NTIP2,172,20,34,170.
5.
Attempt a connection to the device with NTCONN. For example, if the server number is 3,
the command would be 3NTCONN1. If the connection is successful, Network Status bit #1
is set (see NTS, TNTS, TNTSF). If the connection is unsuccessful, Error Status bit #23 is
set (see ER, TER, TERF).
6.
Inform the Gem6K of the configuration of the OPTO22. For each module position, use
the NTIO command to specify the type of module in that position.
Gem6K Series Programmer’s Guide
www.comoso.com
n \ m NTIO <i>
Network Server #
Range: 1-6
Module Type. Options are:
1 = Digital/Discrete Inputs
2 = Digital/Discrete Outputs
3 = Analog Inputs
4 = Analog Outputs
Module # on Server “n”
Range: 0-7
For example, if there is a digital input module in slot 0, then the command would be
3\0NTIO1. If there is an Analog Input module in slot 7, then the command would be
3\7NTIO3.
7.
Example
Set the polling rate with the NTPOLL command. 50 milliseconds is recommended. For
example, to set the polling rate to 50 ms on server #3, use the 3NTPOLL50 command. If
there is an error during polling, then Error Status bit #24 will be set.
NTADDR172,34,54,123 ; Set the IP address of the Gem6K
OPTEN0
; Disable the option card (for Fieldbus units only)
RESET
NTFEN2
; Enable network function on Gem6K
RESET
DEL OPTOSU
DEF OPTOSU
2NTIP2,172,34,54,124;
;
2NTCONN1
;
2\1NTIO2
;
2\2NTIO2
;
2\3NTIO1
;
2\4NTIO3
;
2NTPOLL50
;
END
Program
Interaction
Identify an OPTO22 device as Server #2, which is
located at IP address 172.34.54.124
Attempt connection to Server #2 (OPTO22)
Configure OPTO22 module 1 as digital output
Configure OPTO22 module 2 as digital output
Configure OPTO22 module 3 as digital input
Configure OPTO22 module 4 as analog input
Begin polling, set polling interval to 50 ms
Once the OPTO22 is configured and a connection is made, you can then set outputs and check
inputs.
How the Gem6K addresses OPTO22 I/O locations:
The Gem6K addresses each I/O bit by its location on a specific module. (NOTE: I/O
points are not addressed by an absolute 32-bit location on the OPTO22.) Digital input and
output modules have four I/O points, or channels, and are numbered 1-4. Analog input and
output modules have two I/O points, or channels, and are numbered 1-2.
EXAMPLE: OPTO22 is Network Server #3
0
1
2
3
4
5
6
7
Digital
Input
Module
Digital
Input
Module
Digital
Output
Module
Digital
Output
Module
Analog
Output
Module
Analog
Output
Module
Analog
Input
Module
Analog
Input
Module
Input
1
Input
2
Input
3
Input
4
Input
1
Input
2
Input
3
Input
4
Output
1
Output
2
Output
3
Output
4
Output
1
Output
2
Output
3
Output
4
Output
1
Output
2
Output
1
Output
2
Input
1
Input
2
Input
1
Input
2
3\0IN.3
3\3OUT.2
3\5ANO.1
3\7ANI.2
•
To verify the I/O configuration (as per NTIO) and to check the status of each module’s
inputs and outputs, type n\TIO, where “n” is the server number.
•
To set a digital output, type n\mOUT.i-b, where “n” is the server number, “m” is the
Chapter 2. Communication
49
www.comoso.com
module number, “i” is the point number on that module and “b” is the state (1 = on,
0 = off). To set multiple digital outputs on the same module, type n\mOUTbbbb:
Output #1
Output #2
Output #3
Output #4
n \ m OUT b b b b
Network Server #
Range: 1-6
Module # on Server “n”
Range: 0-7
Options for “b” are:
1 = Turn on
0 = Turn off
x = Don’t Change
For example (Server #3), to turn on outputs #1 and #4 and leave outputs #2 and #3 unchanged on module #2, type 3\2OUT1XX1. To turn off only output #4, type 3\2OUT.4-0.
•
To set an analog output voltage, type n\mANO.i-r, where “n” is the server number, “m” is
the module number, “i” is the output number on that module and “r” is the voltage. For
example, to set analog output #1 on module #5 of Server #3 to 6.4V, type 3\5ANO.1=6.4.
•
To read a digital input or output module, use the assignment/comparison operands (n\mIN
or n\mOUT) or the transfer commands (n\mTIN or n\mTOUT). Examples are:
- IF(3\0IN=b1100) is an IF condition that reads all four digital inputs on module #0.
IF(3\0IN.2=b1) is an IF condition that reads only digital input #2 on module #0.
- IF(3\2OUT=b1100) is an IF condition that reads all four outputs on module #2.
IF(3\2OUT.3=b1) is an IF condition that reads only digital output #3 on module #2.
- 3\0TIN transfers the binary status of all four digital inputs on module #0.
3\0TIN.2 transfers the binary status of only digital input #2 on module #0.
- 3\2TOUT transfers the binary status of all four digital outputs on module #2.
3\2TOUT.3 transfers the binary status of only digital output #3 on module #2.
•
To read an analog input or output module, use the assignment/comparison operands
(n\mANI or n\mANO) or the transfer commands (n\mTANI or n\mTANO). Examples are:
- WAIT(3\7ANI.2<2.4) is an WAIT condition that reads analog input #2 on module #7.
- IF(3\5ANO.1>=1.0) is an IF condition that reads analog output #1 on module #5.
- 3\6TANI transfers the voltage status of both analog inputs on module #6.
3\6TANI.2 transfers the voltage status of only analog input #2 on module #6.
- 3\4TANO transfers the voltage status of both analog outputs on module #4.
3\4TANO.1 transfers the voltage status of only analog output #1 on module #4.
Networking with a DVT Vision System
The DVT client can send trigger commands to the camera. The camera should send back
ASCII strings of the form VARn = 123.456, VARm = 234.567. The strings will be VAR
assignments delineated by commas. These values will then be written to the Gem6K’s VARs.
This data can represent anything, such as an x-y coordinate.
Setup
50
1.
Follow the manufacturer’s setup procedure for the DVT camera.
2.
Connect the Gem6K and DVT camera in a network and configure the Gem6K for
Ethernet communication according to the procedures on page 43.
3.
Choose a Server Connection Number for this device. The Gem6K can support up to 6
simultaneous client connections. Pick a number (1-6) that has not been used already for
another server connection. This will be used to reference the device from now on.
4.
Enter the IP address of the camera and specify a 3 for connection type with the NTIP
command. For example, if the DVT camera is Server #6 and its IP address is
Gem6K Series Programmer’s Guide
www.comoso.com
172.20.34.150, then the command would be 6NTIP3,172,20,34,150.
5.
Example
Program
Interaction
Example
Attempt a connection to the device with NTCONN. For example, if the server number is 6,
the command would be 6NTCONN1. If the connection is successful, Network Status bit
#1 is set (see NTS, TNTS, TNTSF). If the connection is unsuccessful, Error Status bit #23
is set (see ER, TER, TERF).
6NTIP3,172,34,54,150 ; Identify a DVT camera as Server #6, located at
; IP address 172.34.54.150.
6NTCONN1
; Attempt the connection to Server #6
Once a connection has been established, you can write trigger commands to the camera using
the NTWRIT command.
DEL DVT
DEF DVT
6NTCONN1
; Attempt connection to DVT camera
6NTWRIT"DVT commands" ; Write the text "DVT commands" to camera
END
Networking with an Allen-Bradley SLC 5/05 PLC
The Allen-Bradley SLC 5/05 exchanges integer and binary data with the Gem6K. The data
exchange is accomplished by mapping integer variables (VARI) and binary variables (VARB) in
the Gem6K with data elements in the PLC’s integer and binary data files. The Gem6K limits
the amount of variable mapping to 100 binary variables (50 write, 50 read) and 100 integer
variables (50 write, 50 read).
Setup
1.
Follow the manufacturer’s setup procedure for each Allen-Bradley PLC, DVT camera
and OPTO22 Ethernet I/O rack.
2.
Connect the Gem6K and Allen-Bradley PLC in a network and configure the Gem6K for
Ethernet communication according to the procedures on page 43.
3.
Choose a connection number for this device. The Gem6K can support up to 6
simultaneous client connections. Pick a number (1-6) that has not been used already for
another client connection. This will be used to reference the device from now on.
4.
Enter the IP address of the PLC and specify a 1 for connection type with the NTIP
command. For example, if the PLC is Server #5 and its IP address is 172.20.34.124, then
the command would be 3NTIP1,172,20,34,124.
5.
Attempt a connection to the device with NTCONN. For example, if the server number is 5,
the command would be 5NTCONN1. If the connection is successful, Network Status bit
#1 is set (see NTS, TNTS, TNTSF). If the connection is unsuccessful, Error Status bit #23
is set (see ER, TER, TERF).
6.
Map the required integer and binary variables between the Gem6K and the data files in
the Allen-Bradley PLC. There are four mappings possible (a programming example is
provided below).
• Use the NTMPRB command to read up to 50 binary elements from a PLC’s binary file
and write them to VARB variables in the Gem6K.
Chapter 2. Communication
51
www.comoso.com
n NTMPRB i, i, i, i
Network Server #
Range: 1-6
# of Allen-Bradley data file
# of first element in AB data file
(beginning of range)
# of elements in range
# of first binary variable (VARB) in 6K
(beginning of range, max value is 125)
EXAMPLE:
IF:
• Allen-Bradley PLC is server #5
• The PLC’s binary data file 3 has 30
elements. Use data elements 15-29
(15 elements total) for binary data
that is to be shared with the 6K.
• Use the 6K’s binary variables 35-49
(15 variables total) to store the data
from the PLC.
The required mapping command is:
5NTMPRB3,15,15,35
• Use the NTMPRI command to read up to 50 integers elements from a PLC’s Integer
file and write them to VARI variables in the Gem6K.
n NTMPRI i, i, i, i
Network Server #
Range: 1-6
# of Allen-Bradley data file
# of first element in AB data file
(beginning of range)
# of elements in range
# of first integer variable (VARI) in 6K
(beginning of range, max value is 225)
EXAMPLE:
IF:
• Allen-Bradley PLC is server #5
• The PLC’s integer data file 9 has 30
elements. Use data elements 15-29
(15 elements total) for integer data
that is to be shared with the 6K.
• Use the 6K’s integer variables 35-49
(15 variables total) to store the data
from the PLC.
The required mapping command is:
5NTMPRI9,15,15,35
• Use the NTMPWB command to write up to 50 binary values from VARB variables in the
Gem6K to binary elements in a PLC’s binary file.
n NTMPWB i, i, i, i
Network Server #
Range: 1-6
# of Allen-Bradley data file
# of first element in AB data file
(beginning of range)
# of elements in range
# of first binary variable (VARB) in 6K
(beginning of range, max value is 125)
EXAMPLE:
IF:
• Allen-Bradley PLC is server #5
• In the PLC’s binary data file 3, use
data elements 0-14 (15 elements
total) for binary data that is to be
transmitted from the 6K.
• Use the 6K’s binary variables 20-34
(15 variables total) to store the data
to be transmitted to the PLC.
The required mapping command is:
5NTMPWB3,0,15,20
• Use the NTMPWI command to write up to 50 integers values from VARI variables in
the Gem6K to a integer elements in a PLC’s integer file.
n NTMPWI i, i, i, i
Network Server #
Range: 1-6
# of Allen-Bradley data file
# of first element in AB data file
(beginning of range)
# of elements in range
# of first integer variable (VARI) in 6K
(beginning of range, max value is 225)
7.
52
EXAMPLE:
IF:
• Allen-Bradley PLC is server #5
• The PLC’s integer data file 9 has 30
elements. Use data elements 0-14
(15 elements total) for integer data
to be transmitted from the 6K.
• Use the 6K’s integer variables 20-34
(15 variables total) to store the data
to be transmitted to the PLC.
The required mapping command is:
5NTMPWI9,0,15,20
Set the polling rate with the NTPOLL command. 50 milliseconds is recommended. For
example, to set the polling rate to 50 ms on Server #5, use the 5NTPOLL50 command. If
there is an error during polling, Error Status bit #24 will be set (see ER, TER or TERF).
Gem6K Series Programmer’s Guide
www.comoso.com
Example
NTADDR172,34,54,123
OPTEN0
; Set the IP address of the Gem6K
; Disable the option card (for Fieldbus units
only)
RESET
NTFEN2
; Enable network function on Gem6K
RESET
5NTIP1,172,34,54,124 ; Identify network server #5 as an Allen Bradley
PLC
; at IP address 172.34.54.124
5NTCONN1
; Connect to network server #5
5NTMPRB11,7,1,106
; File 11, element 7 in the AB PLC is mapped to
the Gem6K's
; binary variable VARB106
5NTMPRI20,5,2,128
; File 20, elements 5-6 in the AB PLC are mapped
to
; the Gem6K's integer variables VARI128-VARI129,
respectively
5NTMPWB11,3,4,100
; File 11, elements 3-6, in the AB PLC are
mapped to
; the Gem6K's binary variables VARB100-VARB103
5NTMPWI20,3,2,120
; File 20, elements 3-4, in the AB PLC are
mapped to
; the Gem6K's integer variables VARI120-VARB121
5NTPOLL50
; Start polling network server #5, set interval
to 50 ms.
;
*********************************************
************************
; The Gem6K's VARB106 will read from the PLC's File 11, element 7.
; The Gem6K's VARI128-VARI129 will read from the PLC's File 20,
elements 5-6.
; The PLC's File 11, elements 3-6 will read from the Gem6K's
VARB100-VARB103.
; The PLC's File 20, elements 3-4 will read from the Gem6K's
VARI120-VARB121.
;
*********************************************
************************
Program
Interaction
After the connection is established, mapping has been set up, and polling enabled, the Gem6K
starts exchanging data automatically with the PLC. Here is how to:
• Write a binary variable to the PLC: Simply write a value to one of the VARB variables in
the NTMPWB mapping. The new data will be written to the binary file during the next poll.
• Write an integer variable to the PLC: Simply write a value to one of the VARI variables in
the NTMPWI mapping. The new data will be written to the integer file during the next poll.
• Read a binary variable from the PLC: The VARB variables in the NTMPRB mapping
correspond to the values in the binary file in the PLC.
• Read an integer variable from the PLC: The VARI variables in the NTMPRI mapping
correspond to the values in the integer file in the PLC.
Chapter 2. Communication
53
www.comoso.com
Example
VARB100 = HAB79
; Element 3 in file 10 of the AB PLC will be
equal to VARB100
if(VARB106 = B1111111111111111)
; VARB106 will be equal to
variable 7 in
; file 10 of the AB PLC
if(VARI129 = 17)
; Element 6 in file 20 of the AB PLC will be
equal to VARI129
VARI121 = 17
; Element 4 in file 20 of the AB PLC will be
equal to VARI121
Error Conditions
Error Messages
54
The 6K will transmit error message to alert you of certain error conditions. Below is a list of
the error messages related to Ethernet networking.
Error Response
Possible Cause
CONNECTION COULD NOT BE CLOSED OR
ALREADY CLOSED
Tried to close the network server connection (nNTCONNØ)
when the connection was already closed.
CONNECTION COULD NOT BE OPENED
Tried NTCONN1 and failed. Problem could be invalid IP
address or it refused a connection.
CONNECTION ERROR, CONNECTION IS
NOW BEING CLOSED
Connection error or timeout with server. When polling and
get timeout or message aborted. This condition also sets
Error Status bit #23 (see ER, TER, TERF).
CONNECTION IS NOT OPEN
Tried a NTWRIT when connection is not open; or tried a
\TANI or \TANO or \TIN or \TOUT or \TIO when
connection is not open.
CONNECTION IS OPEN - MUST CLOSE
FIRST
Tried to open a network server connection (nNTCONN1)
when the connection was already open.
ERROR, INVALID FILE TYPE, NUMBER
OR SIZE. SETTING NTMP COMMANDS
TO 0 ELEMENTS. CHECK MAPPING.
Tried to read the wrong Allen-Bradley PLC file type, there
are not enough elements in the file, or the file doesn’t exist.
The 6K automatically stop polling all mapped binary and
integer variables (equivalent to executing the
NTMPRBi,i,0,i, NTMPWBi,i,0,i, NTMPRIi,i,0,i,
and NTMPWIi,i,0,i, commands).
ERROR, INVALID STRING
The DVT camera sent an invalid string response.
ETHERNET CAN NOT BE USED WITH
OPTION CARD - SEE OPTEN
Tried to enable Ethernet communication (NTFEN) on a
Fieldbus version of the 6K (part number is 6Kn-PB for
PROFIBUS units, 6Kn-DN for DeviceNet units). You must
disable the internal option card with OPTENØ before
enabling Ethernet communication. The 6K cannot
communicate over a Fieldbus connection and Ethernet
connection simultaneously.
ETHERNET COMMUNICATION MUST BE
ENABLED BEFORE MAKING
CONNECTION - SEE NTFEN
Tried to connect to an Ethernet server (nNTCONN1) before
you enabled Ethernet communication in the 6K with the
NTFEN command.
INVALID CONNECTION NUMBER
Tried to make an NTS assignment or comparison using an
invalid server number (e.g., VARB1 = 7NTS).Tried to
address an Ethernet command to a server connection
number outside of the range 1-6. What’s the difference
between this and the “INVALID SERVER TYPE” error?
INVALID I/O POINT
Tried to read or write an OPTO22 I/O point that is not
configured according to the NTIO command.
INVALID POINT TYPE OR NUMBER,
Tried to set or read an I/O point (with an \IN, \OUT, \ANI,
Gem6K Series Programmer’s Guide
www.comoso.com
Error Response
SEE NTIO
Error Handling
Possible Cause
\ANO, \TANI, \TANO, \TIN, or \TOUT command), but that
I/O point was configured with the NTIO command to be
different I/O type.
INVALID SERVER TYPE
Tried an OPTO22-related command (\TANI, \TANO, \TIN,
\TOUT, \TIO, \IN, \OUT, \ANI, \ANO, etc.) for a nonOPTO22 connection.
NETWORK INPUTS AND OUTPUTS CANNOT
BE ASSIGNED TO A VARSHO
Tried to assign the status of OPTO22 I/O to a VARSHO
variable.
NETWORK IP ADDRESS CANNOT BE
CHANGED WHILE CONNECTION IS
OPEN, SEE NTCONN
Tried to execute an NTIP command while the connection is
open.
NO NETWORK IP ADDRESS SPECIFIED
FOR CONNECTION, SEE NTIP
Tried to connect (nNTCONN1) to a server # that has not yet
been established with the NTIP command, or tried to
connect to a server in an incompatible subnet.
NTFEN MUST BE 1 TO USE THIS
COMMAND
(Peer-to-peer connection only) Tried to execute an NTRATE
command while NTFEN is set to a value other than NTFEN1.
NTRATE MUST BE 0 TO CHANGE NTFEN
(Peer-to-peer connection only) Tried to execute an NTFEN
command while NTRATE is set to a non-zero value.
NTSELP ALREADY ENABLED ON THIS
TASK
NTSELP, which enables program selection via OPTO22
inputs, has already been enabled (if multitasking, it has
been enabled for this specific Task).
OPTION CARD CAN NOT BE USED WITH
ETHERNET - SEE NTFEN
Tried to enable the internal Fieldbus Option card for
PROFIBUS or DeviceNet communication (6Kn-PB and 6KnDN products only) with the OPTEN1 command. You must
disable Ethernet communications with the NTFENØ
command before enabling the Option card. The 6K cannot
communicate over a Fieldbus connection and Ethernet
connection simultaneously.
VARB USED BY OPTION CARD
Tried to map a binary variable to read from or write to an
Allen-Bradley data file, but the variable is already used for
Fieldbus (PROFIBUS or DeviceNet) data transfer functions.
VARIABLE MAPPING CONFLICT, SEE
NTMPRB, NTMPRI, NTMPWI, NTMPWB
MAPPINGS
Tried to map the same 6K VARB or VARI variables for read
and write functions. Or tried to map the same 6K VARB or
VARI variables to another PLC.
The 6K has a Error Status register for logging certain error conditions. If you enable checking
for an error condition (see ERROR command), the 6K will branch to the designated error
program (see ERRORP command) when it detects the error condition. The Ethernet networking
related Error Status register bits are noted below.
ERROR
Bit #
Cause of the Error
23
Ethernet Client
Gosub
Connection Error.
(Can’t connect.)
Ethernet Client Polling Gosub
Error. (After connect and
polling device for data,
polling timeout occurred.
Cause could be
disconnect, client lost
power, etc.)
24
Branch Type How to Remedy the Error
to ERRORP
Clear the error bit (ERROR.23-0), reestablish the Ethernet connection
(nNTCONN1), and then issue ERROR.23-1.
Clear the error bit (ERROR.24-0), reestablish the Ethernet connection
(nNTCONN1), and then issue ERROR.24-1.
Chapter 2. Communication
55
www.comoso.com
Serial Communication
In this section:
• Controlling Multiple Serial Ports
• RS-232 Daisy Chaining
• RS-485 Multi-Drop
Controlling Multiple Serial Ports
Every Gem6K Series product has two serial ports. The “RS-232” connector is referenced as the
“COM2” serial port, and the “RS-232/485” connector is referenced as the “COM1” serial port.
XON/XOFF
The XONOFF command was created to enable or disable XON/XOFF ASCII handshaking.
(XONOFF1 enables XON/XOFF, XONOFFØ disables XON/XOFF) Defaults: XONOFF1 for the
COM1 port, XONOFF1 for the COM2 port.
Controllers on a multi-drop do not support XON/XOFF; to ensure that XON/XOFF is disabled
for COM1, send the PORT1 command followed by the XONOFFØ command.
Configuring the
COM Port
To control the applicable port for setting up serial communication and transmitting ASCII text
strings, use the PORT command. PORT1 selects COM1 and PORT2 selects COM2.
• Serial communication setup commands (see list below) affect the COM port selected
with the last PORT command. For example, to configure the COM1 port for Gem6K
language commands only (e.g., to communicate to the Gem6K product over an RS-485
interface), execute the PORT1 command, then execute the DRPCHKØ command. (refer
to the Gem6K Series Command Reference to details on each command)
DRPCHK........ RP240 Check
E.................... Enable Serial Communication
ECHO............. Enable Communication Echo
BOT ............... Beginning of Transmission Characters
BAUD............. Serial Communication Baud Rate
EOT ............... End of Transmission Characters
EOL ............... End of Line Terminating Characters
ERRBAD........ Error Prompt
ERRDEF........ Program Definition Prompt
ERRLVL........ Error Detection Level
ERRORK........ Good Prompt
XONOFF........ Enable or disable XON/XOFF
• The PORT command also selects the COM port through which the WRITE and READ
commands transmit ASCII text strings. If an RP240 is connected, the DWRITE
command (and all other RP240 commands) will affect the RP240 regardless of the
PORT command setting. If no RP240 is detected, the commands are sent to the COM2
port. DWRITE text strings are always terminated with a carriage return.
56
Gem6K Series Programmer’s Guide
www.comoso.com
Setup for Gem6K
Language or RP240
To configure the COM ports for use with Gem6K language commands or an RP240, use the
DRPCHK command. The DRPCHK command affects the COM port selected with the last PORT
command. The default for COM1 is DRPCHKØ; the default for COM2 is DRPCHKØ. The
DRPCHK setting is automatically saved in non-volatile memory. NOTE: Only one COM port
may be set to DRPCHK2 or DRPCHK3 at any given time.
DRPCHKØ...... Use the COM port for Gem6K language commands only. This is the default
setting for COM1 and COM2, and if using RS-485 half duplex on COM1.
Power-up messages appear on all ports set to DRPCHKØ.
DRPCHK1...... Check for the presence of an RP240 at power-up/reset. If an RP240 is
present, initialize the RP240. If an RP240 is not present, use the port only
for Gem6K language commands. NOTE: RP240 commands will be sent at
power-up and reset.
DRPCHK2...... Check for the presence of an RP240 every 5-6 seconds. If an RP240 is
plugged in, initialize the RP240.
DRPCHK3...... Check for the presence of an RP240 at power-up/reset. If an RP240 is
present, the initialize the RP240. If an RP240 is not present, use the COM
port for DWRITE commands only, and ignore received characters.
Selecting a
Destination Port for
Transmitting from
the Controller
To define the port (COM port) through which the Gem6K product sends its responses, you
have 3 options:
• Do nothing different. The response will be sent to the COM port through which the
request was made. If the command is in a stored program, the report will be sent to the
COM port selected by the most recent PORT command.
• Prefix the command with [. This causes the response to be sent to both COM ports.
(e.g., the [TFS command response will be sent through both COM ports)
• Prefix the command with ]. This causes the response to be sent to the alternative COM
port. For example, if a report back (e.g., ]TAS) is requested from COM1, the response
is sent through COM2. If the command is in a stored program, the report will be sent
out the alternate port from the one selected by the most recent PORT command.
RS-232C Daisy-Chaining
Up to ninety-nine stand-alone Gem6K Series products may be daisy-chained. There are two
methods of daisy-chaining: one uses a computer or terminal as the controller in the chain; the
other uses one Gem6K product as the master controller. Refer to you product’s Installation
Guide for daisy-chain connections.
Follow these steps to implement daisy-chaining:
Step 1
To enable and disable communications on a particular controller unit in the chain, you must use
the Daisy-Chain Address (ADDR) command to establish a unique device address for each the
unit. The ADDR command automatically configures unit addresses for daisy chaining. This
command allows up to 99 units on a daisy chain to be uniquely addressed.
Sending ADDRi to the first unit in the daisy chain sets its address to be (i). The first unit in turn
transmits ADDR(i + 1) to the next unit to set its address to (i + 1). This continues down
the daisy chain until the last unit of (n) daisy-chained units has its address set to (i + n).
Note that a controller with the default device address of zero (0) will send an initial power-up
start message similar to the following:
*PARKER Gem6K MOTION CONTROLLER
*NO REMOTE PANEL
NOTE: For daisy chaining , you can use either PORT1 (COM1 RS232/484 connector), or
PORT2 (COM1 RS 232 connector).
Chapter 2. Communication
57
www.comoso.com
Step 2
Connect the daisy-chain with a terminal as the master (see diagram in the product’s Installation
Guide).
It is necessary to have the error level set to 1 for all units on the daisy-chain (ERRLVL1).
When the error level is not set to 1, the controller sends ERROK or ERRBAD prompts after
each command, which makes daisy-chaining impossible. Send the ERRLVL1 command to
each unit in the chain. (NOTE: To send a the ERRLVL1 command to one specific unit on the
chain, prefix the command with the appropriate unit's device address and an underline.)
Commands PORT1 (or PORT2 if that port is being used):
0_ERRLVL1
1_ERRLVL1
2_ERRLVL1
3_ERRLVL1
;
;
;
;
set
Set
Set
Set
error
error
error
error
level
level
level
level
to
to
to
to
Ø
1
1
1
for
for
for
for
unit
unit
unit
unit
#Ø
#1
#2
#3
After this has been accomplished, a carriage return sent from the terminal will not cause any
controller to send a prompt. Verify this. Instructions below (step 3) show how to set the error
level to 1 automatically on power-up by using the controller's power-up start program (highly
recommended).
After the error level for all units has been set to ERRLVL1, send a Gem6K series command to
all units on the daisy-chain by entering that command from the master terminal.
Commands:
OUT1111
A50
; Turn on onboard outputs 1-4 on all units
; Set accel to 50 (all units)
To send a Gem6K series command to one particular unit on the chain, prefix the command
with the appropriate unit's device address and an underline:
Commands:
2_OUT0
4_OUT0
; Turn off onboard output 1 on unit #2
; Turn off onboard output 1 on unit #4
To receive data from a particular controller on the chain, you must prefix the command with
the appropriate unit's device address and an underline:
Commands:
1_A
*A50
; Request acceleration information from unit #1
; Response from unit #1
Use the E command to enable/disable RS-232C communications for an individual unit. If all
Gem6K controller units on the daisy chain are enabled, commands without a device address
identifier will be executed by all units. Because of the daisy-chain's serial nature, the
commands will be executed approximately 1 ms per character later on each successive unit in
the chain (assuming 9600 baud).
Units with the RS-232C disabled (EØ) will not respond to any commands, except E1;
however, characters are still echoed to the next device in the daisy chain.
Commands:
3_E0
VAR1=1
3_E1
3_VAR1=5
;
;
;
;
Disable RS-232C on unit #3
Set variable #1 to 1 on all other units
Enable RS-232C on unit #3
Set variable #1 to 5 on unit #3
Verify communication to all units by using the techniques described above.
Step 3
58
Now that communication is established, programming of the units can begin (alternatively,
units can be programmed individually by connecting the master terminal to one unit at a time).
To allow daisy-chaining between multiple controllers, the ERRLVL1 command must be used
to prevent units from sending error messages and command prompts. In every daisy-chained
Gem6K Series Programmer’s Guide
www.comoso.com
unit, the ERRLVL1 command should be placed in the program that is defined as the STARTP
program:
Program:
DEF chain
ERRLVL1
GOTO main
END
STARTP chain
;
;
;
;
;
Begin definition of program chain
Set error level to 1
Go to program main
End definition of program chain
Designates program chain as the power-up program
To define program main for unit #0:
Program:
0_DEF main
0_GO
0_END
Step 4
; Begin definition of program main on unit #0
; Start motion
; End definition of program main on unit #0
After all programming is completed, program execution may be controlled by either a master
terminal, or by a Gem6K Series controller used as a master.
Daisy-Chaining
from a Computer or
Terminal
Controlling the daisy-chain from a master computer or terminal follows the examples above:
Daisy-Chaining
from a Master
Gem6K Controller
Controlling the daisy-chain from a master Gem6K controller (the first unit on the daisy-chain)
requires the programs stored in the master controller to control program and command
execution on the slave controllers. The example below demonstrates the use of the WRITE
command to send commands to other units on the daisy chain.
Commands:
0_RUN main
1_RUN main
2_GO1
3_A
;
;
;
;
Run program main on unit #0
Run program main on unit #1
Start motion on unit #2
Get A command response from unit #3
NOTE
The last unit on the daisy-chain must have RS-232C echo disabled (ECHOØ command).
Master controller's main program:
Program:
DEF main
L
WHILE (IN.1 = b0)
NWHILE
GO
WHILE (IN.1 = b1)
NWHILE
WRITE"2_D2000"
WRITE"2_ACK"
LN
END
; Program main
; Indefinite loop
; Wait for input #1 to go active
; Initiate move
; Wait for input #1 to go inactive
;
;
;
;
Send message "2_D2000" down daisy chain
Send message "2_ACK" down the daisy chain
End of loop
End of program main
Controller unit #2 ack program:
Program:
DEF ack
GO1
END
; Program ack
; Start motion
; End of program ack
Chapter 2. Communication
59
www.comoso.com
Daisy-Chaining and RP240s
RP240s cannot be placed in the drive/controller daisy chain; RP240s can only be connected to
the designated RP240 port on a drive/controller. It is possible to use only one RP240 with a
drive/controller daisy-chain to input data for multiple units on the chain. The example below
(for the drive/controller master with an RP240 connected) reads data from the RP240 into
variables #1 (data1) & #2 (data2), then sends the messages 3_Ddata1,data2<CR> and
3_GO<CR>.
Sample portion of code:
L
VAR1=DREAD
VAR2=DREAD
EOT0,0,0,0
WRITE"3_D"
WRVAR1
WRITE","
EOT13,0,0,0
WRVAR2
WRITE"3_GO"
LN
;
;
;
;
;
;
;
;
;
;
;
Indefinite loop
Read RP240 data into variable #1
Read RP240 data into variable #2
Turn off <CR>
Send message "3_D" down the daisy chain
Send variable #1 data down the daisy chain
Send message "," down the daisy chain
Turn on <CR>
Send variable #2 data down the daisy chain
Send message "3_GO" down the daisy chain
End of loop
RS-485 Multi-Drop
Up to 99 Gem6K Series products may be multi-dropped. Refer to your product's Installation
Guide for multi-drop connections.
To establish device addresses, using the ADDR command:
The ADDR command allows you to establish up to 99 unique addresses. To use the ADDR
command, you must address each unit individually before it is connected on the multi drop.
For example, given that each product is shipped configured with address zero, you could set
up a 4-unit multi-drop with the commands below, and then connect them in a multi drop:
1.
2.
3.
4.
Connect the unit that is to be unit #1 and transmit the Ø_ADDR1 command to it.
Connect the unit that is to be unit #2 and transmit the Ø_ADDR2 command to it.
Connect the unit that is to be unit #3 and transmit the Ø_ADDR3 command to it.
Connect the unit that is to be unit #4 and transmit the Ø_ADDR4 command to it.
If you need to replace a unit in the multi drop, send the Ø_ADDRi command to it, where
"i" is the address you wish the new unit to have.
To send a Gem6K command from the master to a specific unit in the multi-drop, prefix the
command with the unit address and an underscore (e.g., 3_OUTØ turns off output #1 on unit
#3). The master unit (if it is not a Gem6K product) may receive data from a multi-drop unit.
The ECHO command was enhanced with options 2 and 3. The purpose is to accommodate an
RS-485 multi-drop configuration in which a host computer communicates to the “master”
Gem6K controller over RS-232 (COM2 port) and the master Gem6K controller communicates
over RS-485 (COM1 port) to the rest of the units on the multi-drop. For this configuration,
the echo setup should be configured by sending to the master the following commands
executed in the order shown. In this example, it is assumed that the master's device address is
set to 1. Hence, each command is prefixed with “1_” to address only the master unit.
60
Gem6K Series Programmer’s Guide
www.comoso.com
1_PORT2........... Subsequent command affects COM1, the RS-485 port
1_ECHO2........... Echo characters back through the other port, COM2
1_PORT1........... Subsequent command affects COM2, the RS-232 port
1_ECHO3........... Echo characters back through both ports, COM1 and COM2
NOTES
Controllers on a multi-drop do not support XON/XOFF. To ensure that XON/XOFF is disabled
for COM1, send the PORT1 command followed by the XONOFFØ command.
Only ECHOØ or ECHO2 can be used.
Chapter 2. Communication
61
www.comoso.com
www.comoso.com
Basic Operation Setup
3
CHAPTER THREE
Basic Operation
Setup
IN THIS CHAPTER
This chapter will enable you to understand and implement these basic operation features:
•
•
•
•
•
•
•
•
•
•
•
•
Before You Begin (setup programs, Motion Planner, resetting, etc.)................. 64
Memory Allocation (CAUTION: Do not place in “setup” program) ........................ 65
Drive Setup (fault level, resolution, disable drive on kill) ......................................... 66
Scaling ................................................................................................................ 67
Positioning Modes .............................................................................................. 71
End-of-Travel Limits .......................................................................................... 74
Homing ............................................................................................................... 79
Encoder-Based Stepper Operation (stepper axes only)....................................... 84
Tuning Procedures (servos only) ........................................................................ 85
Target Zone Mode (servo axes only) .................................................................. 84
Programmable Inputs and Outputs (incl. triggers and auxiliary outputs) ........... 90
Variable Arrays (teaching variable data) ........................................................... 110
www.comoso.com
Before You Begin
WARNING
The Gem6K Product is used to control your system's electrical and mechanical components.
Therefore, you should test your system for safety under all potential conditions. Failure to do so
can result in damage to equipment and/or serious injury to personnel.
Setup Parameters Discussed in this Chapter
Below is a list of the setup parameters discussed in this chapter. You can check the status of each parameter setting by
entering the respective setup command without any command fields (e.g., typing LIMFNC <cr> displays the current
function and state of each limit input). Some setup parameters are also reported with the TSTAT and TASF status
commands (these and other status commands are described on page 222).
Setup Parameter
Command
See Pg.
Memory (status with TDIR & TMEM) ...........MEMORY.............11 & 65
Drive Setup............................................................................66
Drive resolution (stepper only) ..............DRES
Drive disable on kill................................KDRIVE
Drive stall detection ...............................DSTALL
Scaling...................................................................................67
Enable scaling factor .............................SCALE
Acceleration scaling factor.....................SCLA
Distance scaling factor ..........................SCLD
Velocity scaling factor............................SCLV
Positioning Mode...................................................................71
Continuous or preset .............................MC
Preset: absolute or incremental.............MA
Encoder Based Stepper Operation (stepper only) ................84
Encoder resolution.................................ERES
Encoder capture/counting enable..........ENCCNT
Use encoder as counter ........................ENCSND ((keep?))
Stall detection ........................................ESTALL
Kill when stall is detected ......................ESK
Stall deadband.......................................ESDB
Tuning Procedures (servos only) ..........................................85
Current loop bandwidth .........................DIBW
Torque/force limit...................................DMTLIM
Velocity limit...........................................DMVLIM
Notch filter A depth ................................DNOTAD
Notch filter A frequency .........................DNOTAF
Notch filter A quality factor.....................DNOTAQ
Notch filter B depth ................................DNOTBF
Notch filter B quality factor.....................DNOTBQ
Notch filter B frequency ........................DNOTBF
Notch lead filter break frequency ..........DNOTLD
Notch lag filter break frequency ............DNOTLG
Position loop bandwidth ........................DPBW
Velocity loop bandwidth ........................DVBW
Load damping .......................................LDAMP
Load-to-rotor inertia ratio
or load-to-force mass ratio ....................LJRAT
Acceleration feed forward gain .............DNOTBF
Servo control signal offset .....................SGAF
Integrator enable ..................................SGINTE
Current damping ratio ...........................SGIRAT
64
Gem6K Series Programmer’s Guide
Setup Parameter
Command
See Pg.
Target Zone end-of-move settling criteria (servo axes)........ 84
Target zone mode enable..................................................... STRGTE
Target distance zone ...................................................... STRGTD
Target velocity zone........................................................ STRGTV
Target settling timeout period ......................................... STRGTT
Programmable Input Functions ............................................ 90
Define input functions ........................... INFNC & LIMFNC
Input active level ................................... INLVL & LIMLVL
Input debounce ..................................... INDEB
Trigger interrupt - special functions ...... TRGFN
Trigger interrupt - lockout time.............. TRGLOT
Virtual Inputs......................................... IN
Programmable Output Functions.......................................... 90
Define output functions ......................... OUTFNC
Output active level ................................ OUTLVL
End-of-travel limits................................................................ 74
Limit function assignments ................... LIMFNC & INFNC
Hardware – enabled ............................. LH
Hardware – deceleration....................... LHAD
Hardware – s-curve decel..................... LHADA
Hardware – active level of input............ LIMLVL
Software – enabled............................... LS
Software – deceleration ........................ LSAD
Software – s-curve decel ...................... LSADA
Software – negative direction limit ....... LSNEG
Software – positive direction limit ........ LSPOS
Homing ................................................................................. 79
Limit function assignments ................... LIMFNC & INFNC
Acceleration .......................................... HOMA
S-curve acceleration ............................. HOMAA
Deceleration.......................................... HOMAD
S-curve deceleration............................. HOMADA
Backup to home.................................... HOMBAC
Final approach direction ....................... HOMDF
Stopping edge of switch........................ HOMEDG
Home switch active level ...................... LIMLVL
Velocity ................................................ HOMV
Velocity of final approach...................... HOMVF
Home to Z channel input....................... HOMZ
Variable Arrays (teaching variable data) .............................. 110
Initialize numeric variable for data ........ VAR or VARI
Define data program and program size DATSIZ
Set data pointer & establish increment . DATPTR
Reset data pointer to specific location .. DATRST
www.comoso.com
Position loop ratio .................................SGPRAT
Velocity/position bandwidth ratio ..........SGPSIG
Velocity feed forward gain ....................SGVP
Velocity damping ratio ..........................SGVRAT
Using a Setup Program
The features described in this chapter are configured with certain Gem6K Series commands,
commonly referred to as “setup commands.” We recommend placing these commands (except
MEMORY) into a special “setup program” that is executed to prepare the Gem6K Series
product for subsequent controller operations. Further details about setup programming are
provided in the Creating and Executing a Setup Program section, page 13.
USE THE START WIZARD IN MOTION PLANNER
The easiest way to get started with your setup program is to use the Start Wizard in Motion
Planner’s Wizard Editor. After the Start wizard is finished, you can include additional setup
code according to your programming needs. The Start wizard also defines which program is
your start-up (STARTP) program. If you do not wish to program you entire application with
the Wizards, you can use the Start wizard to get the basic setup accomplished, and then
copy the generated code into the Program Editor. (Wizard version 4.2 or later required)
Resetting the Controller
There are two primary ways to reset the Gem6K controller (listed below).
• Cycle power.
• Execute the RESET command.
When the controller is reset, most of the previously entered command parameters are returned
to their original factory default values. All programs and variables, as well as certain
command values, are retained in non-volatile memory (see page 35). If a start-up program is
assigned with the STARTP command, resetting the controller will automatically execute that
program. If you are using an RP240, the RESET function is available if you use the default
menu system (see page 130).
Memory Allocation
For details about memory allocation, refer to Storing Programs on page 11.
CAUTION
Issuing a new MEMORY command (e.g., MEMORY200000,100000) will erase all existing
programs and compiled profiles residing in the Gem6K product’s memory. To determine the
status of memory allocation, use the TMEM command.
Do not place the MEMORY command in the program assigned as the startup (STARTP)
program. Doing so would erase all programs and segments upon cycling power or issuing
the RESET command.
Chapter 3. Basic Operation Setup
65
www.comoso.com
Drive Setup
Drive Stall Detection (stepper only)
The DSTALL command determines if the encoderless stall feature will be checked as Drive
Stall indicator.
The state of the encoderless stall feature can be monitored at all times with Extended Axis
Status bit #17 (reported with TASX, TASF, and the ASX assignment/comparison operand).
When a Drive Stall is detected, the Gem6K responds as follows: (this response is the same as
that for Encoder Stall Detection, which is enabled with the ESTALL command)
• The stall is reported with Axis Status bit #12 (reported with TAS, TASF, and AS).
• If ERROR error-checking bit #1 is enabled (ERROR.1-1):
- The stall is reported with Error Status bit #1 (reported with TER, TERF, and ER).
- The Gem6K branches to the assigned ERRORP program.
• If the Kill-on-Stall feature is enabled (ESK1), the Gem6K immediately kills motion.
Drive Resolution (stepper only)
The drive resolution controls the number of steps the Gem6K controller considers as a full
revolution for the motor drive. The drive’s resolution is set with the DRES command (default
is 25,000 steps/rev).
Disable Drive On Kill (servo only)
Normally, when you issue a Kill command (K, !K, or <ctrl>K) or activate an input
configured as a kill input (see INFNCi-C or LIMFNCi-C command), motion is stopped at
the hard limit (LHAD/LHADA) deceleration setting and the drives are left in the enabled state
(DRIVE1).
However, your application may require you to disable (shut down or de-energize) the drives in
a Kill situation to, for example, prevent damage to the motors or other system mechanical
components. If so, set the controller to the Disable Drive on Kill mode with the KDRIVE1
command. In this mode, a kill command or kill input will shut down the drives immediately,
letting the motors free wheel (without control from the drives) to a stop.
66
Gem6K Series Programmer’s Guide
www.comoso.com
Scaling
Units of Measure without Scaling
Scaling is disabled (SCALEØ) as the factory default condition:
• Steppers: When scaling is disabled, all distance values entered are in commanded counts
(sometimes referred to as motor steps), and all acceleration, deceleration and velocity
values entered are internally multiplied by the DRES command value.
• Servos:
Motion Attribute
Accel/Decel
Units of Measure (per feedback source)
Encoder
Resolver
Revs/sec/sec *
revs/sec/sec
Velocity
Revs/sec *
revs/sec
Distance
Counts (steps) **
Counts (steps) **
* All accel/decel & velocity values are internally multiplied by the ERES value.
** Distance is measured in the counts received from the feedback device.
What is Scaling?
Scaling allows you to program acceleration, deceleration, velocity, and position values in
units of measure that are appropriate for your application. The SCALE command is used to
enable or disable scaling (SCALE1 to enable, SCALEØ to disable). The motion type(s) you are
using in your application determines which scale factor commands you need to configure:
Type of Motion
Accel/Decel
Scaling
Velocity
Scaling
Distance
Scaling
Standard Point-to-Point Motion
SCLA
SCLV
SCLD
Following
SCLA
SCLV
SCLD for follower distances
SCLMAS for master distances
* A separate description of implementing scaling for Following is provided on page 70.
When Should I Define Scaling Factors?
Scaling calculations are performed when a program is defined or downloaded. Consequently,
you must enable scaling (SCALE1) and define the scaling factors (SCLD, SCLA, SCLV,
SCLMAS) prior to defining (DEF), uploading (TPROG), or running (RUN) the program.
NOTE
All scaling parameters
are saved in batterybacked RAM
RECOMMENDATION: Place the scaling commands at the beginning of your program file,
before the location of any defined programs. This ensures that the motion parameters in
subsequent programs in your program file are scaled correctly. When you use Motion Planner’s
Setup Generator wizard, the scaling commands are automatically placed in the appropriate
location in your program file.
ALTERNATIVE: Scaling factors could be defined via a terminal emulator just before defining
or downloading a program. Because scaling command values are saved in battery-backed
RAM (remembered after you cycle power or issue a RESET command), all subsequent program
definitions and downloads will be scaled correctly.
NOTES
• Scaling commands are not allowed in a program. If there are scaling commands in a
program, the controller will report an error message (“COMMAND NOT ALLOWED IN
PROGRAM”) when the program is downloaded.
• If you intend to upload a program with scaled motion parameters, be sure to use
Motion Planner. Motion Planner automatically uploads the scaling parameters and
places them at the beginning of the program file containing the uploaded program from
the controller. This ensures correct scaling when the program file is later downloaded.
Chapter 3. Basic Operation Setup
67
www.comoso.com
Acceleration & Deceleration Scaling (SCLA)
Steppers:
If scaling is enabled (SCALE1), all accel/decel values entered are internally
multiplied by the acceleration scaling factor to convert user units/sec/sec to
commanded counts/sec/sec. The scaled values are always in reference in
commanded counts, regardless of the existence of an encoder.
Servos:
If scaling is enabled (SCALE1), all accel/decel values entered are internally
multiplied by the acceleration scaling factor to convert user units/sec/sec to
encoder or analog input counts/sec/sec.
All accel/decel commands for point-to-point motion (e.g., A, AA, AD, HOMA, HOMAD, JOGA,
etc.) are multiplied by the SCLA command value.
As the accel/decel scaling factor (SCLA) changes, the
resolution of the accel and decel values and the
number of positions to the right of the decimal point
also change (see table at right). An accel/decel value
with greater resolution than allowed will be truncated
(e.g., if scaling is set to SCLA10, the A9.9999
command would be truncated to A9.9).
SCLA value
(steps/unit2)
1-9
10 - 99
100 - 999
1000 - 9999
10000 - 99999
100000 - 999999
Decimal
Places
0
1
2
3
4
5
Use the following equations to determine the range of acceleration and deceleration values for
your product.
Axis Type Min. Accel or Decel (resolution)
Stepper
0.001 ∗ DRES
SCLA
Servo
0.001 ∗ ERES
Encoder feedback:
SCLA
Resolver
Max. Accel or Decel
999.9999 ∗ DRES
SCLA
999.9999 ∗ ERES
Encoder feedback:
SCLA
Resolver
Velocity Scaling (SCLV)
Steppers:
If scaling is enabled (SCALE1), all velocity values entered are internally
multiplied by the velocity scaling factor to convert user units/sec to
commanded counts/sec. The scaled values are always in reference to
commanded counts (sometimes referred to as “motor steps”).
Servos:
If scaling is enabled (SCALE1), all velocity values entered are internally
multiplied by the velocity scaling factor to convert user units/sec to encoder or
analog input counts/sec.
All velocity commands for point-to-point motion (e.g., V, HOMV, HOMVF, JOGVH, JOGVL,
etc.) are multiplied by the SCLV command value.
As the velocity scaling factor (SCLV) changes, the velocity command's range and its decimal
places also change (see table below). A velocity value with greater resolution than allowed
will be truncated. For example, if scaling is set to SCLV10, the V9.9999 command would
be truncated to V9.9.
68
SCLV Value
(counts/unit)
Velocity Resolution
(units/sec)
Decimal Places
1-9
10 - 99
100 - 999
1000 - 9999
10000 - 99999
100000 - 999999
1
0.1
0.01
0.001
0.0001
0.00001
0
1
2
3
4
5
Gem6K Series Programmer’s Guide
www.comoso.com
Use the following equations to determine the maximum velocity range for your product type.
Max. Velocity for Steppers
6,5000,000
SCLV
n = maximum velocity as set
by the PULSE command.
Max. Velocity for Servos
(determined by feedback source selected for axis #1)
Encoder Feedback:
6,5000,000
SCLV
Resolver
Distance Scaling (SCLD and SCLMAS)
Steppers:
Servos:
If scaling is enabled (SCALE1), all distance values entered are internally
multiplied by the distance scaling factor to convert user units to commanded
counts (“motor steps”).
If scaling is enabled (SCALE1), all distance values entered are internally
multiplied by the distance scaling factor to convert user units to encoder or
analog input counts.
All distance commands for point-to-point motion (e.g., D, PSET, REG, SMPER) are multiplied
by the SCLD command value.
Scaling for Following Motion: The SCLD command defines the follower’s distance scale factor, and
the SCLMAS command defines the master's distance scale factor. The Following-related commands that
are affected by SCLD and SCLMAS are listed in the table below.
Commands Affected by Master Scaling (SCLMAS)
Commands Affected by Follower Scaling (SCLD)
FMCLEN: Master Cycle Length
FOLRN: Follower-to-Master Ratio (Numerator)
FMCP: Master Cycle Position Offset
FSHFD: Preset Phase Shift
FOLMD: Master Distance
GOWHEN: Conditional GO (left-hand variable ≠ PMAS)
FOLRD: Follower-to-Master Ratio (Denominator)
TPSHF & [ PSHF ]: Net Position Shift of Follower
GOWHEN: Conditional GO (left-hand variable is PMAS)
TPSLV & [ PSLV ]: Position of Follower Axis
TPMAS & [ PMAS ]: Position of Master Axis
TVMAS & [ VMAS ]: Velocity of Master Axis
Fractional Step Truncation
If you are operating in the
incremental mode (MAØ), or
specifying master distance
values with FOLMD, when the
distance scaling factor (SCLD or
SCLMAS) and the distance value
are multiplied, a fraction of one
step may be left over. This
fraction is truncated when the
distance value is used in the
move algorithm. This truncation
error can accumulate over a
period of time, when performing
incremental moves continuously
in the same direction. To
eliminate this truncation
problem, set SCLD or SCLMAS to
1, or a multiple of 10.
As the SCLD or SCLMAS scaling factor changes, the distance command's range and its
decimal places also change (see table below). A distance value with greater resolution than
allowed will be truncated. For example, if scaling is set to SCLD400, the D105.2776
command would be truncated to D105.277.
SCLD or SCLMAS Value
(counts/unit)
Distance Resolution
(units)
Distance Range
(units)
Decimal
Places
1-9
10 - 99
100 - 999
1000 - 9999
10000 - 99999
100000 - 999999
1.0
0.10
0.010
0.0010
0.00010
0.00001
0 - ±999999999
0.0 - ±99999999.9
0.00 - ±9999999.99
0.000 - ±999999.999
0.0000 - ±99999.9999
0.00000 - ±9999.99999
0
1
2
3
4
5
Chapter 3. Basic Operation Setup
69
www.comoso.com
Scaling Example —
Steppers
User has a 25,000 step/rev motor/drive attached to 5-pitch leadscrew. The user wants to program motion
parameters in inches; therefore the scale factor calculation is: 25,000 steps/rev x 5 revs/inch = 125,000
steps/inch. For instance, with a scale factor of 125,000, the operator could enter a move distance value of
2.000 and the controller would send out 250,000 pulses, corresponding to two inches of travel.
SCALE1
DRES25000
SCLD125000
SCLV125000
SCLA125000
Scaling Example —
Servos
Enable scaling
Set drive resolution to 25,000 steps/rev
Allow entering distance in inches
Allow entering velocity in inches/sec
Allow entering accel/decel in inches/sec/sec
User has a 4,000 count/rev servo motor/drive system (using a 1000-line encoder) attached to a 5-pitch
leadscrew. The user wants to position in inches; therefore, the scale factor calculation is 4,000 counts/rev
x 5 revs/inch = 20,000 counts/inch.
ERES4000
SCALE1
SCLD20000
SCLV20000
SCLA20000
Scaling Example —
Following
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
Set encoder resolution to 4000 steps/rev (post quadrature)
Enable scaling
Allow entering distance values in inches
Allow entering velocity values in inches/sec
Allow entering accel/decel values in inches/sec/sec
Select ANI feedback for axis #1
Enable scaling
Allow entering distance values in volts
Allow entering velocity values in volts/sec
Allow entering accel/decel values in volts/sec/sec
Select encoder feedback for both axes (prepare for motion)
Typically, the master and follower scale factors are programmed so that master and follower units are the
same, but this is not required. Consider the scenario below as an example.
The master is a 1000-line encoder (4000 counts/rev post-quadrature) mounted to a 50 teeth/rev pulley
attached to a 10 teeth/inch conveyor belt, resulting in 80 counts/tooth (4000 counts/50 teeth = 80
counts/tooth). To program in inches, you would set up the master scaling factor with the SCLMAS800
command (80 counts/tooth ∗ 10 teeth/inch = 800 counts/inch).
The follower axis is a servo motor with position feedback from a 1000-line encoder (4000 counts/rev).
The motor is mounted to a 4-pitch (4 revs/inch) leadscrew. Thus, to program in inches, you would set
up the follower scaling factor with the SCLD16000 command (4000 counts/rev ∗ 4 revs/inch = 16000
counts/inch).
SCALE1
SCLMAS800
SCLD16000
70
Gem6K Series Programmer’s Guide
;
;
;
;
;
Enable scaling
Master scaling:
(80 counts/tooth * 10 teeth/inch = 800 counts/inch)
Follower scaling:
(4000 counts/rev ∗ 4 revs/inch = 16000 counts/inch)
www.comoso.com
Positioning Modes
The Gem6K controller can be programmed to position in either the preset (incremental or
absolute) mode or the continuous mode. You should select the mode that will be most
convenient for your application. For example, a repetitive cut-to-length application requires
incremental positioning. X-Y positioning, on the other hand, is better served in the absolute
mode. Continuous mode is useful for applications that require constant movement of the load
based on internal conditions or inputs, not distance.
Refer also to the
Scaling section on
page 67.
Positioning modes require acceleration, deceleration, velocity, and distance commands
(continuous mode does not require distance). The table below identifies these commands and
their units of measure, and which scaling command affects them.
Parameter
Units (Unscaled), Stepper
Units (Unscaled), Servo
Unit Scaling Command *
Acceleration
revs/sec2
encoder/resolver: revs/sec2
SCLA
Deceleration
revs/sec2
encoder/resolver: revs/sec2
SCLA
Velocity
revs/sec
encoder/resolver: revs/sec
SCLV
Distance
steps
counts
SCLD ***
* Scaling must first be enabled with the SCALE1 command. For details on scaling, refer to page 67.
*** An axis assigned as a master (for Following) is scaled by the SCLMAS command.
On-The-Fly (Pre-emptive Go) Motion Profiling
While motion is in progress (regardless of the positioning mode), you can change these
motion parameters to affect a new profile:
•
•
•
•
•
•
•
Acceleration (A) — s-curve acceleration not allowed during on-the-fly changes
Deceleration (AD) — s-curve deceleration not allowed during on-the-fly changes
Velocity (V)
Distance (D)
Preset or Continuous Positioning Mode Selection (MC)
Incremental or Absolute Positioning Mode Selection (MA)
Following Ratio Numerator and Denominator (FOLRN and FOLRD, respectively)
The motion parameters can be changed by sending the respective command (e.g., A, V, D,
MC, etc.) followed by the GO command. If the continuous command execution mode is
enabled (COMEXC1), you can execute buffered commands; otherwise, you must prefix each
command with an immediate command identifier (e.g., !A, !V, !D, !MC, etc., followed by
!GO). The new GO command pre-empts the motion profile in progress with a new profile
based on the new motion parameter(s).
For more information, see On-The-Fly Motion Profiling on page 155.
Chapter 3. Basic Operation Setup
71
www.comoso.com
Preset Positioning Mode
A preset move is a point-to-point move of a specified distance. You can select preset moves by
putting the Gem6K controller into preset mode (canceling continuous mode) using the MCØ
command. Preset moves allow you to position the motor/load in relation to the previous stopped
position (incremental mode—enabled with the MAØ command) or in relation to a defined zero
reference position (absolute mode—enabled with the MA1 command).
Incremental Mode
Moves
The incremental mode is the controller's default power-up mode. When using the Incremental
Mode (MAØ), a preset move moves the motor/load the specified distance from its starting
position. For example, if you start at position N, executing the D6ØØØ command in the MAØ
mode will move the motor/load 6,000 units from the N position. Executing the D6ØØØ
command again will move the motor/load an additional 6,000 units, ending the move 12,000
units from position N.
You can specify the direction of the move by using the optional sign + or - (e.g., D+6ØØØ or
D-6ØØØ). Whenever you do not specify the direction (e.g., D6ØØØ), the unit defaults to the
positive (+) direction.
Example
SCALE0
MA0
A2
V5
D4000
GO
GO
D-8000
GO
Absolute Mode
Moves
;
;
;
;
;
;
;
;
;
;
;
Disable scaling
Set to Incremental Position Mode
Set acceleration to 2 units/sec/sec
Set velocity to 5 units/sec
Set distance to 4,000 positive units
Initiate motion on (move 4,000 positive units)
Repeat the move
Set distance to 8,000 negative units
(return to original position)
Initiate motion on (move 8,000 units in the negative
direction and end at its original starting position)
A preset move in the Absolute Mode (MA1) moves the motor/load the distance that you specify
from the absolute zero position.
Establishing a Zero Position
One way to establish the zero position is to issue the PSET command when the load is at the
location you would like to reference as absolute position zero (e.g., PSETØ defines the current
position as absolute position zero). Steppers with encoder feedback can use the PESET command
set the absolute encoder position in ENCCNT1 mode.
The zero position is also established when the Go Home (HOM) command is issued, the absolute
position register is automatically set to zero after reaching the home position, thus designating the
home position as position zero.
The direction of an absolute preset move depends upon the motor's/load's position at the
beginning of the move and the position you command it to move to. For example, if the
motor/load is at absolute position +12,500, and you instruct it to move to position +5,000
(e.g., with the D5ØØØ command), it will move in the negative direction a distance of 7,500
steps to reach the absolute position of +5,000.
The Gem6K controller retains the absolute position, even while the unit is in the incremental
mode. To ascertain the absolute position, use the TPC and PC commands.
Example
SCALE0
MA1
PSET0
A5
V3
D4000
GO
D8000
GO
D0
GO
72
;
;
;
;
;
;
;
;
;
;
;
;
;
Disable scaling
Set the controller to the absolute positioning mode
Set current absolute position to zero
Set acceleration to 5 units/sec/sec
Set velocity to 3 units/sec
Set move to absolute position 4,000 units
Initiate move (move to absolute position +4,000)
Set move to absolute position +8,000
Initiate move (starting from position +4,000, move 4,000
additional units in the positive direction to position +8,000)
Set move to absolute position zero
Initiate move (starting at absolute position +8,000,
move 8,000 units in the negative direction to position zero)
Gem6K Series Programmer’s Guide
www.comoso.com
Continuous Positioning Mode
The Continuous Mode (MC1) is useful in these situations:
• Applications that require constant movement of the load
• Synchronize the motor to external events such as trigger input signals
• Changing the motion profile after a specified distance or after a specified time period
(T command) has elapsed
You can manipulate the motor movement with either buffered or immediate commands. After
you issue the GO command, buffered commands are not executed unless the continuous
command execution mode (COMEXC1 command) is enabled. Once COMEXC1 is enabled,
buffered commands are executed in the order in which they were programmed. More
information on the COMEXC mode is provided on page 14.
The command can be specified as immediate by placing an exclamation mark (!) in front of
the command. When a command is specified as immediate, it is placed at the front of the
command queue and is executed immediately.
Example A
COMEXC1
COMEXS1
MC1
A10
V1
GO
WAIT(VEL=1)
T5
S1
WAIT(MOV=b0)
COMEXC0
; When the move
; Enable continuous command processing mode
; Allow command execution to continue after stop
; Sets mode to continuous
; Sets acceleration to 10
; Sets velocity to 1
; Initiates move (Go)
; Wait to reach continuous velocity
; Time delay of 5 seconds
; Initiate stop
; Wait for motion to completely stop
; Disable continuous command processing mode
is executed, the load will accelerate to 1 unit/sec,
; continue at that rate for 5 seconds, and then decelerate to a stop.
Example B
DEF prog1
COMEXC1
COMEXS1
MC1
A10
V1
GO
WAIT(VEL=1)
T3
A50
V10
GO
T5
S1
WAIT(MOV=b0)
COMEXC0
END
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
Begin definition of program prog1
Enable continuous command processing mode
Allow command execution to continue after stop
Set to continuous positioning mode
Set acceleration to 10
Set velocity to 1
Initiate move (Go)
Wait for motor to reach continuous velocity
Time delay of 3 seconds
Set acceleration to 50
Set velocity to 10
Initiate acceleration and velocity changes
Time delay of 5 seconds
Initiate stop
Wait for motion to completely stop
Disable continuous command processing mode
End definition of program prog1
While in continuous mode, motion can be stopped if:
• You issue an immediate Stop (!S) or Kill (!K or ctrl/K) command.
• The load trips an end-of-travel limit switch or encounters a software end-of-travel limit.
• The load trips a registration input (a trigger input configured with the INFNCi-H
command to function as a registration input).
• The load trips an input configured as a kill input (INFNCi-C or LIMFNCi-C) or a
stop input (INFNCi-D or LIMFNCi-D).
NOTE
While the axis is moving, you cannot change the parameters of some commands (such as DRIVE
and HOM). This rule applies during the COMEXC1 mode and even if you prefix the command with an
immediate command identifier (!). For more information, refer to Restricted Commands During
Motion on page 17.
Chapter 3. Basic Operation Setup
73
www.comoso.com
Linear Motion
All Gemini drives operate internally in rotary units. If you use a linear motor,
you must convert some of the motion parameters to their rotary equivalents:
A ....................
AA ..................
AD ..................
ADA ................
D ....................
HOMA ..............
HOMV ..............
HOMVF ............
LHAD ..............
LHADA ............
LSAD ..............
LSADA ............
PSET ..............
REG ................
REGLOD ..........
STRGTD ..........
STRGTV ..........
V ....................
Acceleration
Acceleration (S-Curve)
Deceleration
Deceleration (S-Curve)
Distance/Position
Home Acceleration
Home Velocity
Home Final Velocity
Hardware EOT Limit Decel
Hardware EOT Limit Decel (S-Curve)
Software EOT Limit Decel
Software EOT Limit Decel (S-Curve)
Absolute Position Reference
Registration Distance
Registration Lockout Distance
Target Zone Distance
Target Zone Velocity
Velocity
NOTE: Motor setup is handled differently. If you use the Motion Planner
setup wizard, you may enter the motor data in linear units and the software
converts them to rotary units before they are downloaded to the drive.
To make the conversion from linear to rotary and vice versa, the motor electrical
pitch, or DMEPIT, must be known. The electrical pitch relates the linear distance
required for the equivalent of one rotary motor revolution. Mechanically, the
definition of the electrical pitch is the linear distance between two magnets
comprising a full magnetic cycle. The illustration (below) shows an example of
an electrical pitch of 42mm (DMEPIT42). NOTE: Parker linear motors have an
electrical pitch of 42mm.
;
;
;;
;
;;;
; ;
Linear motor track
N
S
N
S
N
S
N
S
42 mm
Definition of DMEPIT (Electrical Pitch)
The feedback resolution (ERES) value must be set to the number of counts for
the electrical pitch (1 rev).
ERES =
1m
DMEPIT (mm) # counts
# counts
×
×
=
1m
1000 mm
1 (rev)
1 (rev)
1
424
3 1424
3 1442443
from encoder
conversion
from motor
Most linear encoders are metric, and most of those are 1 micron (1 µm):
1 micron encoder =
1 count 1,000,000 counts
=
1 µm
m
Use the following formulas to convert from linear to rotary units. An sample
conversion for position, acceleration, and velocity is provided on page 76.
74
Gem6K Series Programmer’s Guide
www.comoso.com
Linear Position
• D (distance)
• PSET (absolute
position reference)
• REG (registration
distance)
• REGLOD (registration
lockout distance)
• STRGTD (target zone
distance)
Metric:
Position rotary (counts) =
# counts
× Position linear (m)
1 ( m)
1
424
3
from encoder
English:
Positionrotary (counts) =
# counts .0254 (m)
×
× Positionlinear (in)
1 ( m)
1 (in)
1
424
3
from encoder
Positionrotary (counts) =
# counts .0254 (m) 12 (in)
×
×
× Positionlinear ( ft )
1 ( m)
1 (in)
1 ( ft )
1
424
3
from encoder
Linear Velocity
• V (velocity)
• HOMV (home velocity)
• HOMVF (home final
velocity)
• STRGTV (target
velocity)
Linear Acceleration
•
•
•
•
•
•
•
A (acceleration)
AA (s-curve accel)
AD (deceleration)
AD (s-curve decel)
HOMA (home accel)
LHAD (hard limit decel)
LHADA (hard limit
s-curve decel)
• LSAD (soft limit decel)
• LSADA (soft limit
s-curve decel)
Metric:
Velocity rotary (rps ) =
1000 (mm)
1
×
× Velocity linear (m / s )
DMEPIT (mm)
1 ( m)
English:
Velocity rotary (rps ) =
1
25.4 (mm)
×
× Velocitylinear (in / s )
DMEPIT (mm)
1 (in)
Velocityrotary (rps ) =
1
25.4 (mm) 12 (in)
×
×
× Velocitylinear ( ft / s )
1 (in)
1 ( ft )
DMEPIT (mm)
Metric:
Accel rotary (rpss ) =
1000 (mm)
1
×
× Accellinear (m / s 2 )
DMEPIT (mm)
1 ( m)
English:
Accelrotary (rpss) =
1
25.4 (mm)
×
× Accellinear (in / s 2 )
DMEPIT (mm)
1 (in)
Accel rotary (rpss ) =
25.4 (mm) 12 (in)
1
×
×
× Accellinear ( ft / s 2 )
DMEPIT (mm)
1 (in)
1 ( ft )
Chapter 3. Basic Operation Setup
75
www.comoso.com
Conversion
Example
Using a Parker 406-LXR-M-D15-E2 linear motor, the electrical pitch is 42mm
(DMEPIT42) and the encoder is 1 micron. Here, we will convert an acceleration of
10 inches/sec2, a velocity of 5 inches/sec, and a distance of 20 inches:
1. Calculate ERES in counts/rev (result is ERES42000):
ERES =
1 000 000 counts
1 ( m)
42 (mm) 42 000 counts
×
×
=
1 ( m)
1000 (mm) 1 (rev)
1 (rev)
1442443 14243 1
424
3
from encoder
conversion
from motor
2. Convert an acceleration of 10 inches/sec2 to its rotary equivalent in revs/sec2:
Accelrotary (rpss ) =
1
25.4 (mm)
×
× 10 (in / s 2 ) = 6.0476 rpss
42 (mm)
1 (in)
3. Convert a velocity of 5 inches/sec to its rotary equivalent in revs/sec:
Velocityrotary (rps) =
1
25.4 (mm)
×
× 5 (in / s ) = 3.0238 rps
42 (mm)
1 (in)
4. Convert a distance of 20 inches to its rotary equivalent in counts:
Positionrotary (counts) =
1 000 000 counts .0254 (m)
×
× 20.0 (in) = 508 000
1 ( m)
1 (in)
1442443
from encoder
The program values resulting from these conversions are:
ERES42000
A6.0476
V3.0238
D508000
76
Gem6K Series Programmer’s Guide
;
;
;
;
;
Set
Set
(10
Set
Set
encoder resolution to 42000 counts/rev
acceleration to 6.0476 revs/sec/sec
inches/sec/sec)
velocity to 3.0238 revs/sec (5 inches/sec)
distance to 508,000 counts (20 inches)
www.comoso.com
End-of-Travel Limits
Related Commands:
LH .............Hard limit enable
LHAD .........Hard limit decel
LHADA .......Hard limit decel (s)
LIMLVL .....Limit switch polarity
LS .............Soft limit enable
LSAD .........Soft limit decel
LSADA .......Soft limit decel (s)
LSNEG .......Soft limit (negative)
LSPOS .......Soft limit (positive)
TLIM .........Hard limit status
TASF .........Bits 15-18 indicate if
..................hard or soft limit
..................was encountered
TERF .........Bit 2: hard limit hit
..................Bit 3: soft limit hit
..................(must enable ERROR
..................checking bits 2 & 3)
ERROR .......Bit 2 or 3 is enabled,
..................the Gem6K will
branch to
..................the ERRORP program
..................if a hard or soft limit
..................is encountered
The Gem6K controller can respond to both hardware and software end-of-travel limits. The
purpose of hardware and software end-of-travel limits is to prevent the motor’s load from
traveling past defined limits. Software and hardware limits are typically positioned in such a
way that when the software limit is reached, the motor/load will start to decelerate toward the
hardware limit, thus allowing for a much smoother stop at the hardware limit. Software limits
can be used regardless of incremental or absolute positioning. When a hardware or software
end-of-travel limit is reached, the Gem6K controller stops that axis using the respective
hardware deceleration rate (set with LHAD & LHADA) or software limit deceleration rate (set
with LSAD & LSADA).
How to set up hardware end-of-travel limits (for each axis):
1. Connect the end-of-travel limit inputs according to the instructions in your Gem6K
product’s Installation Guide. To help assure safety, connect normally-closed switches
and leave the active level at default “active low” setting (set with the LIMLVL
command).
2. (Optional) Define the inputs to be used as end-of-travel inputs for the respective axes.
NOTE: When the Gem6K product is shipped from the factory, the inputs on the
“LIMITS/HOME” connectors are factory-configured with the LIMFNC command to
function as end-of-travel and home limits for their respective axes. If you intend to use
digital inputs on an external I/O brick as limit inputs:
a. Assign the limit function to the external input with the INFNC command.
For example, 1INFNC9-1R assigns the “axis 1 positive end-of-travel limit”
function to the 1st input on SIM2 (I/O point 9) of I/O brick 1.
b. Reassign the respective “LIMITS/HOME” input to a non-limit function with the
LIMFNC command. For example, LIMFNC1-A assigns the “general-purpose
input” function to limit input 1 (normally assigned the “axis 1 positive end-oftravel limit” function).
3. Set the hard limit deceleration rate (LHAD & LHADA) to be used when the limit switch
is activated. The LHADA command allows you to define an s-curve deceleration.
Steppers: If your system is moving heavy loads or operating at high velocities, you may
need to decrease the LHAD command value (deceleration rate) to prevent the motor
from stalling.
NOTES ON HARDWARE LIMITS
• Gem6K controllers are shipped from the factory with the hardware end-of-travel limits
enabled, but not connected. Therefore, motion will not be allowed until you do
one of the following:
- Install limit switches or jumper the end-of-travel limit terminals to the GND terminal
(refer to your product's Installation Guide for wiring instructions).
- Disable the limits with the LH command (recommended only if the load is not
coupled).
- Reverse the active level of the limits by executing the LIMLVL0 command for the
respective axis.
Chapter 3. Basic Operation Setup
77
www.comoso.com
How to set up software end-of-travel limits (for each axis):
1. Use the LS command to enable the software end-of-travel limits/
2. Define the positive-direction limit with the LSPOS command, and define the negativedirection limit with the LSNEG command. If you have scaling enabled (SCALE1), these
limit values are scaled by the SCLD command. Both software limits may be defined
with positive values.
NOTES ON SOFTWARE LIMITS
Programming
Example
•
The software limits (LSPOS & LSNEG) are referenced from a position of absolute
zero. or negative values. Care must be taken when performing incremental moves
because the software limits are always defined in absolute terms. They must be
large enough to accommodate the moves, or a new zero reference position must be
defined (using the PSET command) before each move.
•
To ensure proper motion when using soft end-of-travel limits, be sure to set the
LSPOS value to an absolute value greater than the LSNEG value.
In this sample of code (not a complete program), the hardware and software limits are enabled.
The distance scaling command (SCLD) is used to define software limit locations in revolutions
from the absolute zero position (assumes a 4000 step/rev resolution). Deceleration rates are
specified for both software and hardware limits. If a limit is encountered, the motor will
decelerate to a stop.
; *********************************************************
; These scaling setup commands are downloaded before the
; limit setup commands are executed:
SCALE1
; Enable scaling
SCLD4000
; Program soft limit distance in revs
SCLA4000
; Program soft limit accel/decel in revs/sec/sec
ERES4000
; Set encoder resolution to 4000 steps/rev
; *********************************************************
LH3
; Enable limits 1 and 2, disable limits 3 and 4
LHAD10
; Set hard limit deceleration
LSAD5
; Set soft limit deceleration
LSNEG0
; Set negative direction soft limit
; (0 revs)
LSPOS10
; Establish positive soft limit
; (10 revs)
LS3
; Enable soft limits
78
Gem6K Series Programmer’s Guide
www.comoso.com
Homing (Using the Home Inputs)
Refer to the product's
Installation Guide for
instructions to wire a
hardware home limit
switch.
The homing operation is a sequence of moves that position an axis using the Home Limit input
and/or the Z Channel input of an incremental encoder. The goal of the homing operation is to
return the load to a repeatable initial starting location.
Zero Reference After Homing: As soon as the homing operation is successfully completed,
the absolute position register is reset to zero, thus establishing a zero reference position.
The homing operation has several potential homing functions you can customize to suit the
needs of your application (illustrations of the effects of these commands are presented below):
Command
Homing Function (see respective command descriptions for further details)
Default
HOM ...............Initiate the homing move. To start the homing move in the positive
direction, use HOMØ; to home in the negative direction, use HOM1.
HOMx
(do not home)
HOMA.............Acceleration while homing.
HOMA1Ø
(10 units/sec2)
HOMAA...........S-curve acceleration while homing.
HOMAA10
(10 units/sec2)
HOMAD...........Deceleration while homing.
HOMAD10
(10 units/sec2)
HOMADA.........S-curve deceleration while homing.
HOMADA10
(10 units/sec2)
HOMBAC.........Back up to home. The load will decelerate to a stop after encountering
the active edge of the home region, and then will move in the opposite
direction at the HOMVF velocity until the active edge of the home region
is encountered. Allows the use of HOMEDG and HOMDF.
HOMBAC0
(function disabled)
HOMDF........... Final approach direction —during backup to home (HOMBAC) or during
homing to the Z channel input of an incremental encoder (HOMZ).
HOMDF0
(positive direction)
HOMEDG.........Specify the side of the home switch on which to stop (either the
positive-travel side or the negative-travel side).
HOMEGD0
(positive-travel
side of switch)
LIMLVL.........Define the home limit input active level (i.e., the state, high or low,
which is to be considered an activation of the input). To use a normallyopen switch, select active low (LIMLVL0); to use a normally-closed
switch, select active high (LIMLVL1).
LIMLVL0
(active-low, use a
normally-open
switch)
HOMV............. Velocity while seeking the home position (see also HOMVF).
HOMV1
(1 unit/sec)
HOMVF...........Velocity while in final approach to home position—during backup to
home (HOMBAC) or during homing to the Z channel input of an
incremental encoder (HOMZ).
HOMVF.1
(0.1 unit/sec)
HOMZ.............Home to the Z channel input from an incremental encoder. NOTE: The
home limit input must be active prior to homing to the Z channel.
HOMZ0
(function disabled)
Homing Status:
Status of homing moves
is stored in bit #5 of the
axis status register
(indicates whether or not
the home operation was
successful). To display
the status, use the TASF
command or the TAS
command. To use the
status in a conditional
expression (e.g., for an
IF statement), use the
AS assignment/comparison operator.
NOTES ABOUT HOMING
• Avoid using pause and resume functions during the homing operation. A pause command
(PS or !PS) or pause/resume input (input configured with the INFNCi-E or LIMFNCi-E
command) will pause the homing motion. However, when the subsequent resume
command (C or !C) or pause/resume input occurs, motion will resume at the beginning of
the homing motion sequence.
Direction
Positive Direction
• Relevance of positive and negative direction: Negative
Edge of Home
Edge of Home
Home Switch
Active Region
Negative Direction
End-of-Travel Limit
Positive Direction
End-of-Travel Limit
• If an end-of-travel limit is encountered during the homing operation, the motion will be
reversed and the home switch will be sought in the opposite direction. If a second limit is
encountered, the homing operation will be terminated, stopping motion at the second limit.
Chapter 3. Basic Operation Setup
79
www.comoso.com
Figures A and B show the homing operation when HOMBAC is not enabled. “CW” refers to
the positive direction and “CCW” refers to the negative direction.
Figure A:
Home Active
Region
Velocity
Home Profile Attributes (commands):
• Start home move in positive
direction (HOM0)
• Backup To Home disabled
(HOMBAC0)
Position
Initial
Position
CCW Edge
of Home
CCW
Limit
CW Edge
of Home
CW
Limit
Figure B:
Home Active
Region
Velocity
Home Profile Attributes (commands):
• Start home move in negative
direction (HOM1)
• Backup To Home disabled
(HOMBAC0)
CCW Edge
of Home
CCW
Limit
Positive Homing,
Backup to Home
Enabled
CW Edge
of Home
Initial
Position
Position
CW
Limit
The seven steps below describe a sample homing operation when HOMBAC is enabled (see
Figure C). The final approach direction (HOMDF) is CW and the home edge (HOMEDG) is the
CW edge. “CW” refers to the positive direction and “CCW” refers to the negative direction.
NOTE
To better illustrate the direction changes in the backup-to-home operation, the illustrations in
the remainder of this section show the backup-to-home movements with varied velocities. In
reality, the backup-to-home movements are performed at the same velocity (HOMVF value).
Step 1
A CW home move is started with the HOMØ command at the HOMA and HOMAA
accelerations. Default HOMA is 10 revs (or inches) per sec2.
Step 2
The HOMV velocity is reached (move continues at that velocity until home input goes
active).
The CCW edge of the home input is detected, this means the home input is active.
At this time the move is decelerated at the HOMAD and HOMADA command values. It
does not matter if the home input becomes inactive during this deceleration.
After stopping, the direction is reversed and a second move with a peak velocity
specified by the HOMVF value is started.
This move continues until the CCW edge of the home input is reached.
Upon reaching the CCW edge, the move is decelerated at the HOMAD and HOMADA
command values, the direction is reversed, and another move is started in the CW
direction at the HOMVF velocity.
As soon as the home input CW edge is reached, this last move is immediately
terminated. The load is at home and the absolute position register is reset to zero.
Step 3
Step 4
Step 5
Step 6
Step 7
80
Gem6K Series Programmer’s Guide
www.comoso.com
Figure C:
Velocity
Home Active
Region
Initial
Position
Position
CCW Edge
of Home
CW Edge
of Home
CCW
Limit
Home Profile Attributes (commands):
• Start home move in positive
direction (HOM0)
• Backup To Home enabled
(HOMBAC1)
• Final approach direction is
positive (HOMDF0)
• Stop on the positive-travel side
of the home switch active region
(HOMEDG0)
CW
Limit
Figures D through F show the homing operation for different values of HOMDF and HOMEDG,
when HOMBAC is enabled. “CW” refers to the positive direction and “CCW” refers to the
negative direction.
Figure D:
Velocity
Home Active
Region
Initial
Position
Position
CCW Edge
of Home
CW Edge
of Home
CCW
Limit
CW
Limit
Home Profile Attributes (commands):
• Start home move in positive
direction (HOM0)
• Backup To Home enabled
(HOMBAC1)
• Final approach direction is
positive (HOMDF0)
• Stop on the negative-travel side
of the home switch active region
(HOMEDG1)
Figure E:
Velocity
Home Active
Region
Initial
Position
Position
CCW Edge
of Home
CW Edge
of Home
CCW
Limit
CW
Limit
Home Profile Attributes (commands):
• Start home move in positive
direction (HOM0)
• Backup To Home enabled
(HOMBAC1)
• Final approach direction is
negative (HOMDF1)
• Stop on the positive-travel side
of the home switch active region
(HOMEDG0)
Figure F:
Velocity
Home Active
Region
Initial
Position
CCW
Limit
Position
CCW Edge
of Home
CW Edge
of Home
CW
Limit
Home Profile Attributes (commands):
• Start home move in positive
direction (HOM0)
• Backup To Home enabled
(HOMBAC1)
• Final approach direction is
negative (HOMDF1)
• Stop on the negative-travel side
of the home switch active region
(HOMEDG1)
Chapter 3. Basic Operation Setup
81
www.comoso.com
Negative Homing,
Backup to Home
Enabled
Figures G through J show the homing operation for different values of HOMDF and HOMEDG,
when HOMBAC is enabled. “CW” refers to the positive direction and “CCW” refers to the
negative direction.
Figure G:
Velocity
Home Active
Region
CCW Edge
of Home
CW Edge
of Home
Position
Initial
Position
CCW
Limit
CW
Limit
Home Profile Attributes (commands):
• Start home move in negative
direction (HOM1)
• Backup To Home enabled
(HOMBAC1)
• Final approach direction is negative
(HOMDF1)
• Stop on the negative-travel side of
the home switch active region
(HOMEDG1)
Figure H:
Velocity
Home Active
Region
CCW Edge
of Home
CW Edge
of Home
Position
Initial
Position
CCW
Limit
CW
Limit
Home Profile Attributes (commands):
• Start home move in negative
direction (HOM1)
• Backup To Home enabled
(HOMBAC1)
• Final approach direction is negative
(HOMDF1)
• Stop on the positive-travel side of
the home switch active region
(HOMEDG0)
Figure I:
Velocity
Home Active
Region
CCW Edge
of Home
CW Edge
of Home
Position
Initial
Position
CCW
Limit
CW
Limit
Home Profile Attributes (commands):
• Start home move in negative
direction (HOM1)
• Backup To Home enabled
(HOMBAC1)
• Final approach direction is positive
(HOMDF0)
• Stop on the negative-travel side of
the home switch active region
(HOMEDG1)
Figure J:
Velocity
Home Active
Region
CCW Edge
of Home
CCW
Limit
82
Gem6K Series Programmer’s Guide
CW Edge
of Home
Position
Initial
Position
CW
Limit
Home Profile Attributes (commands):
• Start home move in negative
direction (HOM1)
• Backup To Home enabled
(HOMBAC1)
• Final approach direction is positive
(HOMDF0)
• Stop on the positive-travel side of
the home switch active region
(HOMEDG0)
www.comoso.com
Figures K through O show the homing operation when homing to an encoder index pulse, or Z
channel, is enabled (HOMZ1). The Z-channel will only be recognized after the home input is
activated. It is desirable to position the Z channel within the home active region; this reduces
the time required to search for the Z channel. “CW” refers to the positive direction and
“CCW” refers to the negative direction.
Figure K:
Home Active
Region
Velocity
Z Channel
Active Region
Initial
Position
CW Edge
of Home
CCW Edge
of Home
CCW
Limit
Position
CW
Limit
Home Profile Attributes (commands):
• Z-Channel homing enabled (HOMZ1)
• Start home move in negative direction
(HOM1)
• Backup To Home enabled (HOMBAC1)
• Final approach direction is negative
(HOMDF1)
• Stop on the negative-travel side of the
z-channel active region (HOMEDG1)
Figure L:
Home Active
Region
Velocity
Z Channel
Active Region
Initial
Position
CW Edge
of Home
CCW Edge
of Home
CCW
Limit
Position
CW
Limit
Home Profile Attributes (commands):
• Z-Channel homing enabled (HOMZ1)
• Start home move in negative direction
(HOM1)
• Backup To Home enabled (HOMBAC1)
• Final approach direction is positive
(HOMDF0)
• Stop on the positive-travel side of the
z-channel active region (HOMEDG0)
Figure M:
Z Channel
Active Region
Velocity
Home Active
Region
CCW Edge
of Home
Position
Initial
Position
CW Edge
of Home
CCW
Limit
CW
Limit
Home Active
Region
Z Channel
Active Region
Velocity
Figure N:
Initial
Position
Position
CCW Edge
of Home
CW Edge
of Home
CCW
Limit
CW
Limit
Figure O:
Home Active
Region
Z Channel
Active Region
Velocity
Homing Using
The Z-Channel
Initial
Position
CCW
Limit
Position
CCW Edge
of Home
CW Edge
of Home
CW
Limit
Home Profile Attributes (commands):
• Z-Channel homing enabled (HOMZ1)
• Start home move in negative direction
(HOM1)
• Backup To Home enabled (HOMBAC1)
• Final approach direction is positive
(HOMDF0)
• Stop on the positive-travel side of the
z-channel active region (HOMEDG0)
Home Profile Attributes (commands):
• Z-Channel homing enabled (HOMZ1)
• Start home move in positive direction
(HOM0)
• Backup To Home disabled (HOMBAC0)
• Final approach direction is positive
(HOMDF0)
• Stop on the positive-travel side of the
z-channel active region (HOMEDG0)
Home Profile Attributes (commands):
• Z-Channel homing enabled (HOMZ1)
• Start home move in positive direction
(HOM0)
• Backup To Home enabled (HOMBAC1)
• Final approach direction is positive
(HOMDF0)
• Stop on the positive-travel side of the
z-channel active region (HOMEDG0)
Chapter 3. Basic Operation Setup
83
www.comoso.com
Encoder-Based Stepper Operation (stepper only)
When using an encoder in a stepper application, you may configure the following:
• Encoder resolution
• Stall Detection & Kill-on-Stall, Stall Deadband
• Encoder-based position reference and position capture
Encoder Resolution
You must specify the encoder resolution with the ERES command.
Stall Detection & Kill-on-Stall
To detect stalls without
an encoder, refer to
Drive Stall Detection on
page 66.
The ESTALL1 command enables the drive to detect encoder-based stall conditions.
NOTE: Encoder count reference must be enabled (ENCCNT1) before stall detect (ESTALL)
can be used.
If used with Kill-on-Stall enabled (ESK1 command), the move in progress will be aborted upon
detecting a stall. If queried with the ER or the AS commands, the user may branch to any other
section of program when a stall is detected. Refer to the ER, and AS command descriptions in
the Gem6K Series Command Reference for more information.
Kill-on-Stall functions only if the stall detection is enabled (ESTALL1).
WARNING
Disabling the Kill-on-Stall function with the ESKØ command will allow the controller to finish
the move regardless of a stall detection, even if the load is jammed. This can potentially
damage user equipment and injure personnel.
Stall Deadband
Another encoder set-up parameter is the Stall Backlash Deadband (ESDB) command. This
command sets the number of commanded counts of error allowed, after a change in direction,
before a stall will be detected. This is useful for situations in which backlash in a system can
cause false stall situations.
Encoder Set Up Example
The example below illustrates the features discussed in the previous paragraphs. The DRES
statement defines the motor resolutions. The ERES statement defines the number of encoder
steps per encoder revolution. A standard 1000-line encoder is used that produces 4000
quadrature steps/rev. Encoder counting (ENCCNT), stall detect (ESTALL) and kill-on-stall
(ESK1) are enabled. If a stall is detected (more than 10 steps out without an encoder step
back), the motor's movement is killed. The ESDB statement defines the stall deadband.
Examples for 4 Axes
(command line samples)
DRES25000
ERES4000
ESK1
ENCCNT1
ESTALL1
ESDB0
84
Gem6K Series Programmer’s Guide
;
;
;
;
;
;
;
Set drive resolution
Set encoder resolution
Enable kill motion on stall
Enable encoder counting (this is
required for ESTALL to work)
Enable stall detection
Set stall deadband
www.comoso.com
Encoder Count/Capture Referencing
Use ENCCNT to configure steppers to reference either the encoder position or the commanded
position when capturing the position (see INFNCi-H) and checking the encoder position (PE
and TPE). When checking the actual velocity (VELA and TVELA), ENCCNT determines whether
the velocity, in units of revs/sec, is derived with the encoder resolution (ERES) or the drive
resolution (DRES). The default setting (ENCCNT0) references the commanded position.
Example
INFNC1-H
ENCCNT10
; Configure trigger 1A as position capture input
; Capture encoder position when trigger 1A is activated
Tuning Procedures (servos only)
During the Express Setup procedure shown in the Hardware Installation Guide, Chapter 2
Installation, the drive uses default values for tuning parameters, based upon the motor
information you entered. That procedure assumes that the motor is unloaded. In the following
tuning procedures, you will enter in system information that will characterize the load on the
motor. Before you continue with the tuning procedures you must have first configured
your drive for the motor being used. See the Express Setup section in the Hardware
Installation Guide, Chapter 2: Installation.
Entering Load Settings
The main load setting you will adjust is LJRAT, which is the load-to-rotor inertia value for
your system. The more accurately you know this value, the closer your tuning bandwidth
settings will correspond to the actual dynamic performance of your system. If you only know
this value approximately, you can adjust this value until you achieve the system performance
you desire. The total system inertia is given by the following formula:
Total system inertia = motor rotor inertia*(1 + LJRAT)
If your system has significant mechanical damping, you will also want to adjust the LDAMP
setting which specifies system damping provided by the load. If you know that you have
significant damping in your system from your load but do not know its exact value, you can
adjust this value until you achieve the system performance that you desire.
Both the LJRAT and the LDAMP values can be set in the Full Setup section of the GV6K
wizard in Motion Planner. These values can also be set in the terminal mode of Motion
Planner. During the tuning process you may want to use the terminal emulator to establish
appropriate values for these parameters and then upload and save the drive’s full configuration
settings for use with other units.
Position Mode Tuning
For most applications, the default tuning parameters for position mode are set to provide
good, stiff motor shaft performance for a given load setting. With the default tuning
parameters set in the Express Setup procedure, you need only set the system load-to-rotor
inertia ratio and your system will be tuned. If your system has significant mechanical
damping, you may need to set the system damping as well. Should you wish to modify the
default values and fine tune your system for position mode, use the following procedures:
WARNING
This procedure causes the motor shaft to move. Make sure that shaft motion will not damage
equipment or injure personnel.
Chapter 3. Basic Operation Setup
85
www.comoso.com
Position Mode Tuning Procedure
Primary Tuning Procedure
1. Disable the drive.
2. Configure the drive for position tuning mode (DMODE17). In this mode, the drive
commands an alternating 1/4 revolution step change in position at a one second
repetition rate.
3. Enable the drive and observe your system’s response. (If necessary, you can connect an
oscilloscope as described in Advanced Tuning below.)
Ringing or an oscillating response indicates that the position loop bandwidth is too
high. To eliminate oscillations:
• decrease bandwidth using the DPBW command.
A sluggish response indicates that position loop bandwidth is too low. To improve the
response:
• increase bandwidth by using the DPBW command.
NOTE: Ringing, oscillations, or a sluggish response can also indicate inaccurate drive
settings for LJRAT or LDAMP.
4. After you achieve a satisfactory system response, reconfigure the drive for position
mode (DMODE12). This completes the primary tuning procedure.
If you are unable to achieve a satisfactory response, proceed to the advanced tuning
procedure below.
Advanced Tuning Procedure
1. Disable the drive.
2. Configure the drive for position tuning mode (DMODE17). In this mode, the drive
commands an alternating 1/4 revolution step change in position at a one second
repetition rate.
(In some applications a different move profile may give better results. Choose a move
similar to that required by your application, but using fast acceleration and deceleration
rates. Be sure the maximum velocity of your move is well below the rated speed of
your drive/motor combination.
3. Configure ANALOG MONITOR A to show position error (DMONAV3).
4. Connect one channel of your oscilloscope to the drive’s ANALOG MONITOR A (pin
21). Connect your oscilloscope’s ground to the drive’s ANALOG GROUND (pin 25).
5. Adjust your oscilloscope to display position error. (The analog monitor can be scaled,
in percent, with the DMONAS command.)
6. Enable the drive and observe your system’s response. Position error will increase
during acceleration, but should decay smoothly to near zero without significant ringing
or instability.
Ringing or an oscillating response indicates that the position loop bandwidth is too
high, or the position loop damping is too low. To eliminate ringing or oscillations:
• decrease bandwidth using the DPBW command; then, if necessary:
• adjust damping by using the SGPRAT command. Use the value that gives the best
performance.
• in applications with backlash or high static friction, disabling the velocity integrator
(SGINTE0) can help improve stability.
• NOTE: In position mode, the velocity loop bandwidth tracks changes in position loop
bandwidth by a ratio set by the SGPSIG command.
A sluggish response indicates that position loop bandwidth is too low, or position loop
damping is too high. To improve the response:
• increase bandwidth by using the DPBW command; then, if necessary:
• adjust damping by using the SGPRAT command. Use the value that gives the best
performance.
NOTE: Ringing or a sluggish response can also indicate inaccurate drive settings for
LJRAT or LDAMP.
7. After you achieve a satisfactory system response, reconfigure the drive for position
mode (DMODE12). This completes the advanced tuning procedure.
If ringing or oscillations persist, and do not seem to be affected by the above adjustments, you
may need to use notch filters or lead/lag filters. See the Filter Adjustments procedure below.
86
Gem6K Series Programmer’s Guide
www.comoso.com
Filter Adjustments
If the previous tuning procedures did not eliminate ringing or oscillations, then mechanical
resonances may be causing problems with your system’s response.
Before trying the procedure below, we recommend that you check your mechanical system,
especially the mechanical stiffness and mounting rigidity of your system. Use bellows or disk
style couplers, not helical couplers. Once you have optimized your mechanical system, filters
may allow increased performance, without causing system instability.
Filters can improve response by reducing system gain over the same frequencies that contain
resonances. You can then increase the gain for frequencies outside this range, without exciting
the resonance and causing instability.
The first procedure below describes how to set the drive’s two notch filters, to reduce
resonance and improve your system’s response. The second and third procedures describe
how to set the drive’s lead and lag filters.
WARNING
These procedures cause the motor shaft to move. Make sure that shaft motion will not damage
equipment or injure personnel.
Notch Filter Adjustment Procedure
1. Configure the analog monitor to show q-axis current (DMONAV19).
2. Configure the drive for position tuning mode (DMODE17).
3. Configure DMTLIM to approximately 1/3 of the default value for your Compumotor
motor.
4. Connect one channel of your oscilloscope to the drive’s ANALOG MONITOR A (pin
21). Connect your oscilloscope’s ground to the drive’s ANALOG GROUND (pin 25).
5. From the oscilloscope display, observe the system’s response to the tuning mode’s step
input. Note the frequency of the oscillatory current waveform that is superimposed on
the 1 Hz step command signal.
6. Using the DNOTAF command, set the notch filter to the frequency noted in Step 5.
7. Using the DNOTAD command, slowly increase the depth of the notch filter from 0.0 to
1.0 until the ringing decreases.
8. Continue to observe the response to step command signal. Ringing should be reduced
or eliminated.
9. Adjust the Q of the filter (DNOTAQ command). Use the following guidelines:
• Set Q as low as possible. Resonances change with load; therefore, your system
will be more robust with a lower Q value. (Default = 1)
• If Q is too low, system stiffness will be reduced outside the resonant range.
• If Q is too high, the response peak may shift in frequency.
10. After reducing the resonance, you may notice a second resonance. Use the second
notch filter (DNOTBF, DNOTBD and DNOTBQ) to reduce the second resonance.
Follow the same procedure as outlined in steps 1 – 9 above.
11.
If you are done adjusting filters, reconfigure DMTLIM to its default value.
Otherwise, proceed to the Lag Filter Adjustment procedure below.
Chapter 3. Basic Operation Setup
87
www.comoso.com
Lag Filter Adjustment Procedure
The lag filter can act as a low pass filter, and reduce the effects of electrical noise on the
commanded torque. (It can also reduce the effects of resonance at low frequencies—
below 60 Hz—where the notch filters are not effective.)
1. As described in Steps 2 – 3 in the Notch Filter Adjustment procedure above, reduce
DMTLIM and connect an oscilloscope.
2. Verify that the lead filter is turned off (DNOTLDØ).
3. Configure the drive for position tuning mode. Observe the system’s response to the
tuning mode’s step input.
4. Choose a value for the lag filter (DNOTLG) that reduces low frequency resonance and
provides satisfactory system performance.
5. If you are done adjusting filters, reconfigure DMTLIM to its default value. Otherwise,
proceed to the Lead /Lag Filter Adjustment procedure below.
Lead/Lag Filter Adjustment Procedure
The lead filter can counteract the effects of the lag filter at higher frequencies. Do not use
the lead filter by itself—if you use the lead filter, you must also use the lag filter.
1. As described in Steps 2 – 3 in the Notch Filter Adjustment procedure above, reduce
DMTLIM and connect an oscilloscope.
2. Set the lag filter (DNOTLG) as described above.
3. Configure the drive for position tuning mode. Observe the system’s response to the
tuning mode’s step input.
4. Choose a value for the lead filter (DNOTLD) that improves system performance. This
value will typically be higher in frequency than the lag filter setting.
5. You must choose a value for the lead filter that is higher in frequency than the lag filter
value. However, do not set the lead filter higher than four times the lag filter frequency,
or a drive configuration warning will result, and the drive will use the previous filter
settings.
6. If you are done adjusting filters, reconfigure DMTLIM to its default value.
88
Gem6K Series Programmer’s Guide
www.comoso.com
Commanded
Move is actually
Completed
Actual
Time
When the Target Zone
Mode is not enabled, the
move is considered to be
complete and subsequent
moves can be executed at
this point in time.
Velocity
Under default operation (Target Zone Mode
not enabled), the Gem6K product's move
completion criteria is simply derived from the
move trajectory. The Gem6K product
considers the current preset move to be
complete when the commanded trajectory has
reached the desired target position; after that,
subsequent commands/moves can be executed.
Consequently, the next move or external
operation can begin before the actual position
has settled to the commanded position (see
diagram).
Position
Target Zone Mode (move completion criteria for servos only)
Actual
Commanded
Time
To prevent premature command execution before the actual position settles into the
commanded position, use the Target Zone Mode. In this mode, enabled with the STRGTE
command, the move cannot be considered complete until the actual position and actual
velocity are within the target zone (that is, within the distance zone defined by STRGTD and
less than or equal to the velocity defined by STRGTV). If the load does not settle into the
target zone before the timeout period set with the STRGTT command, the Gem6K product
detects a timeout error (see illustration below).
If the timeout error occurs, you can prevent subsequent command/move execution only if you
enable the ERROR command to continually check for this error condition, and when it occurs
to branch to a programmed response you can define in the ERRORP program. (Refer to the
Error Handling section, page 30, for error program examples.)
As an example, setting the distance zone to ±5 counts (STRGTD5), the velocity zone to ≤0.5
revs/sec (STRGTV0.5), and the timeout period to 1/2 second (STRGTT500), a move with a
distance of 8,000 counts (D8000) must end up between position 7,995 and 8,005 and settle
down to ≤0.5 rps within 500 ms (1/2 second) after the commanded profile is complete.
Damping is critical
To ensure that a move settles within the distance zone, it must be damped to the point that it
will not move out of the zone in an oscillatory manner. This helps ensure the actual velocity
falls within the target velocity zone set with the STRGTV command (see illustration below).
Failed Move Completion
Position
Successful Move Completion
STRGTD
(Distance Zone)
Commanded
Position
STRGTD
(Distance Zone)
Move
Completed
Actual
Commanded
Move
Completed
Actual
STRGTV
Actual
STRGTT
(Timeout Period)
Time
Timeout Occurs,
Error Bit Set
Commanded
Velocity
Velocity
Time
Commanded
Actual
STRGTT
(Timeout Period)
STRGTV
(Velocity Zone)
(Velocity Zone)
Time
Time
TSTLT
(Actual Settling Time)
Checking the
Settling Time
Checking the Actual Settling Time: Using the TSTLT command, you can display the actual
time it took the last move to settle into the target zone (that is, within the distance zone defined
by STRGTD and less than or equal to the velocity defined by STRGTV). The reported value
represents milliseconds. The TSTLT command is usable whether or not the Target Zone
Settling Mode is enabled with the STRGTE command.
Chapter 3. Basic Operation Setup
89
www.comoso.com
Programmable Inputs and Outputs (onboard and external inputs & outputs)
Programmable inputs and outputs allow the controller to detect and respond to the state of
switches, thumbwheels, electronic sensors, and outputs of other equipment such as drives and
PLCs. The I/O that may be used as programmable inputs and outputs are:
• Onboard I/O:
− Limit inputs on the Drive I/O connector (pins 28, 29, and 31)
− Trigger inputs on the Drive I/O connector (pins 37 and 38). A “master trigger” is
also available on the Drive I/O connector (pin 35). These are general purpose on
board digital inputs but can be redefined as trigger inputs.
− Digital outputs on the Drive I/O connector (pins 41, 43, 45, 46, 48, and 49)
− Relay output on the +24VDC power input connector (screw terminals)
• Expansion I/O located on I/O bricks connected to the Gem6K controller’s “EXPANSION
I/O” connector. Each I/O brick can hold from 1 to 4 of these I/O SIM modules in any
combination (each SIM module provides 8 inputs or outputs, for a total of 32 I/O points
per I/O brick):
− Digital inputs
− Digital outputs
− Analog inputs
− Analog outputs
USING THE STATE OF I/O TO CONTROL PROGRAMMED EVENTS: Based on the
binary state of the inputs and outputs (binary status can be used in assignment/comparison
operations using the LIM, IN and OUT operators), the controller can make program flow
decisions and assign values to binary variables for subsequent mathematical operations. These
operations and the associated program flow, branching, and variable commands are listed below.
Operation based on I/O State
Associated Commands
See Also*
I/O state assigned to a binary variable
LIM, [IN], [OUT], VARB
Variables (page 18)
I/O state used as a basis for
comparison in conditional branching &
looping statements
LIM, [IN], [OUT], IF,
ELSE, NIF, REPEAT,
UNTIL, WAIT, WHILE,
NWHILE
Program Flow Control (page 23)
Input state used as a basis for a
conditional GO
[IN], GOWHEN, LIM
Synchronizing Motion (page 163)
I/O state used as a basis for a
program interrupt (GOSUB)
conditional statement
ONIN
Program Interrupts (page 29)
Mimic PLC functionality by scanning
I/O states with a compiled program
PLCP, SCANP
PLC Scan Mode (page 120)
* Refer also to the respective command descriptions in the Gem6K Series Command Reference.
I/O UPDATE RATE: The programmable inputs and outputs are sampled at the “system
update rate,” which is every 2 ms.
EXPANSION I/O BRICKS: If the I/O brick is disconnected or if it loses power, the
controller will perform a kill (all tasks) and set error bit #18 (see ERROR). (If you disable the
“Kill on I/O Disconnect” mode with KIOENØ, the Gem6K will not perform the kill.) The
controller will remember the brick configuration (volatile memory) in effect at the time the
disconnection occurred. When you reconnect the I/O brick, the controller checks to see if
anything changed (SIM by SIM) from the state when it was disconnected. If an existing SIM
slot is changed (different SIM, vacant SIM slot, or jumper setting), the controller will set the
SIM to factory default INEN and OUTLVL settings. If a new SIM is installed where there was
none before, the new SIM is auto-configured to factory defaults.
90
Gem6K Series Programmer’s Guide
www.comoso.com
Programmable I/O Bit Patterns
The Gem6K has programmable inputs and outputs. The total number of onboard inputs and outputs (analog inputs, digital
inputs, and digital outputs) is fixed. The total number of expansion inputs and outputs (analog inputs, analog outputs,
digital inputs and digital outputs) depends on your configuration of expansion I/O bricks.
These programmable I/O are represented by binary bit patterns, and it is the bit pattern that you reference when
programming and checking the status of specific inputs and outputs. The bit pattern is referenced 1 to n, from left to right.
• Onboard I/O. For example, the status command to check all onboard digital inputs is TIN.
An example response is: *TIN0100_0.
Bit 1
Bit 5
• Expansion I/O. For example, the status command to check all digital inputs on I/O brick 2 is 2TIN.
An example response is: *2TIN0010_0110_1100_0000_XXXX_XXXX_XXXX_XXXX.
I/O Brick 2
Bit 1
Bit 32
Onboard Programmable I/O
I/O
Location
Programming
Status Report, Assignment
Limit Inputs
“DRIVE I/O” connector
LIMFNC, LIMEN, LIMLVL
TLIM, LIM
Digital Inputs
“DRIVE I/O” connector
INFNC, INLVL, INEN, ONIN,
INPLC, INSTW
TIN, IN
Outputs (digital)
“DRIVE I/O” connector
OUT, OUTFNC, OUTLVL,
OUTEN, OUTALL, OUTPLC,
OUTTW, POUT
TOUT, [OUT]
Analog Input
“DRIVE I/O” connector
JOYAXH, JOYCDB,
JOYCTR, JOYEDB,
ANIRNG, ANIMAS
TANI, [ANI]
Limit Inputs (“DRIVE I/O” connector)
Input bit pattern for LIM, TLIM, LIMEN, LIMFNC, and LIMLVL:
Bit #
Pin #
Function *
1
2
3
28
29
31
Positive end-of-travel limit
Negative end-of-travel limit
Home limit
* The functions listed are the factory default functions; other
functions may be assigned with the LIMFNC command.
Sample response to TLIM (limit inputs status) command:
*TLIM110
Chapter 3. Basic Operation Setup
91
www.comoso.com
Digital Inputs (“DRIVE I/O” connector)
Input bit pattern for TIN, IN, INFNC, INLVL, INEN, INPLC, INSTW, ONIN:
Bit # Pin # Function *
1
2
3
4
5
37
38
39
34
35
Input 1 (if assigned, TRIG-A)
Input 2 (if assigned, TRIG-B)
Input 3
Input 4
Input 5 (if assigned, TRIG-M)
* If the input is assigned the “trigger interrupt” function with the INFNCi-H
command:
TRIG-A must be on Input 1
TRIG-B must be on Input 2
TRIG-M must be on input 5
Sample response to TIN (input status) command:
*TIN0010_1
Digital Outputs (“DRIVE I/O” connector)
Output bit pattern for TOUT, [OUT], OUT, OUTFNC, OUTLVL, OUTEN, OUTALL,
OUTPLC, OUTTW, POUT:
Bit # Pin # Function
1
2
3
4
5
6
7
41
43
45
46
48
49
Relay
Output 1.
Output 2.
Output 3.
Output 4.
Output 5.
Output 6.
Output 7.
Sample response to TOUT
(onboard outputs status) command:
*TOUT0000_000
92
Gem6K Series Programmer’s Guide
www.comoso.com
Expansion I/O Bricks
The Gem6K product allows you to expand your system I/O by connecting up to 8 I/O bricks (see Installation Guide for
connections). Expansion I/O bricks may be ordered separately (referred to as the “EVM32”). Each I/O brick can hold from
1 to 4 of these I/O SIM modules in any combination:
SIM Type
Programming
Status Report, Assignment
Digital Inputs SIM (8 inputs)
INFNC, INLVL, INEN, ONIN, INPLC, INSTW
TIN, IN, TIO
Digital Outputs SIM (8 outputs)
OUT, OUTFNC, OUTLVL, OUTEN, OUTALL,
OUTPLC, OUTTW, POUT
TOUT, [OUT], TIO
Analog Inputs SIM (8 inputs)
• Enable/Disable: ANIEN.
• Voltage range: ANIRNG.
• Joystick setup: JOYAXH, JOYAXL, JOYCDB,
JOYCTR, JOYEDB, JOYZ.
• Following master source: ANIMAS, FOLMAS
• Voltage: TANI, ANI, TIO
• Servo position: TPANI, PANI,
FB, TFB
Analog Outputs SIM (8 outputs)
ANO
TANO, [ANO], TIO
Each I/O brick has a unique “brick address”, denoted with the “<B>” symbol in the command syntax. The I/O bricks are
connected in series to the “EXPANSION I/O” connector on the Gem6K. The 1st I/O brick has address #1, the next brick has
address #2, and so on. (NOTE: If you leave out the brick address in the command, the Gem6K product assumes you are
addressing the command to the onboard I/O.) Each I/O brick has 32 I/O addresses, referenced as absolute I/O point
locations:
•
•
•
•
SIM slot 1 = I/O points 1-8
SIM slot 2 = I/O points 9-16
SIM slot 3 = I/O points 17-24
SIM slot 4 = I/O points 25-32
Example:
Gem6K
Controller
I/O Brick #1
I/O Brick #2
Slot #1 (I/O points 1-8)
Slot #1 (I/O points 1-8)
Digital Inputs SIM
Digital Outputs SIM
Slot #2 (I/O points 9-16)
Slot #2 (I/O points 9-16)
Digital Inputs SIM
Digital Inputs SIM
Slot #3 (I/O points 17-24)
Slot #3 (I/O points 17-24)
Digital Inputs SIM
No SIMM installed
Slot #4 (I/O points 25-32)
Slot #4 (I/O points 25-32)
Analog Inputs SIM
Digital Outputs SIM
Sample response to 1TIN (digital inputs status) command:
Sample response to 2TOUT (digital outputs status) command:
*1TIN0000_0010_1100_0000_0100_0001_XXXX_XXXX
*2TOUT0000_0000_XXXX_XXXX_XXXX_XXXX_0000_0000
The TIO command identifies the connected I/O bricks (and installed SIMs), including the status of each I/O point:
*BRICK 1:
1-8:
9-16:
17-24:
25-32:
SIM Type
DIGITAL INPUTS
DIGITAL INPUTS
DIGITAL INPUTS
ANALOG INPUTS
Status
Function
0000_0000
AAAA_AAAA
0000_0000
AAAA_AAAA
0000_0000
AAAA_AAAA
0.000,0.000,0.000,0.000,0.000,0.000,0.000,0.000
*BRICK 2:
1-8:
9-16:
17-24:
25-32:
SIM Type
DIGITAL OUTPUTS
DIGITAL INPUTS
NO SIM PRESENT
DIGITAL OUTPUTS
Status
0000_0000
0000_0000
Function
AAAA_AAAA
AAAA_AAAA
-- SINKING
0000_0000
AAAA_AAAA
-- SOURCING
Chapter 3. Basic Operation Setup
93
www.comoso.com
Input Functions
Programmable input functions may be assigned to the digital inputs on the Gem6K, as well as
to digital inputs on an expansion I/O brick connected to the Gem6K product. The appropriate
input function command (LIMFNC or INFNC) depends on which input you are configuring:
• Onboard limit inputs — use LIMFNC:
LIMFNCi-c
Syntax:
Number of the input.
(see page 141 for input bit assignments)
Letter that selects the desired
function (see list below).
• Onboard digital inputs and digital inputs installed on an expansion I/O brick — use
INFNC:
<B>INFNCi-c
Syntax:
I/O Brick number.
Trigger inputs are considered
collectively as I/O brick 0 (zero),
and are addressed of the I/O brick
number is left off the command.
Letter that selects the desired
function (see list below).
Number of the input.
(see page 143 for input bit assignments)
Virtual Inputs
Virtual Inputs provide programming input functionality for data or external events that are
not ordinarily represented by inputs. The Virtual Input Override (IN) command allows you
to substitute almost any 32-bit data operand as a virtual input brick of 32 inputs (integer
values are converted to binary). Page 8 provides a list of the data operands; the only data
operands that are not allowed are: SIN, COS, TAN, ATAN, VCVT, SQRT, VAR, TW, READ,
DREAD, DREADF, DAT, DPTR, and PI.
The virtual inputs behave similar to real inputs in that they are affected by INEN and
INLVL, and they affect INFNC, INPLC, INSTW, INDUST, ONIN, and GOWHEN(<B>IN=b<bbbb>)
commands. Unlike real inputs, virtual inputs are not affected by the INDEB debounce
setting.
NOTE: A virtual input can only be defined for expansion I/O bricks that are not connected
on the serial I/O network (remember that up to 8 I/O bricks are allowed). For example, if
your Gem6K unit has two I/O bricks, you can designate I/O bricks 3-8 as virtual I/O bricks.
EXAMPLE: Suppose a PLC is sending binary data via the VARB1 command to the Gem6K.
If the binary state of VARB1 is assigned to input brick 2 (2IN=VARB1), the Gem6K can
respond based on programmable input functions set up with the INFNC command.
2TIN
;
;
2IN=VARB1
;
;
VARB1=b10100000 ;
2TIN
;
;
94
Gem6K Series Programmer’s Guide
Brick 2 is not connected; therefore, the Gem6K will
respond with an error message: "*INCORRECT I/O BRICK"
Map the binary state of VARB1 to be the input state
of "virtual" input brick 2 (2IN)
Change "virtual" input brick 2IN to a new VARB1 value
Check the input status. The response will be:
"*2IN1010_0000_0000_0000_0000_0000_0000_0000"
www.comoso.com
Letter Designator
Function
A .................General-purpose input (default function for onboard and expansion digital inputs
on I/O bricks)
B .................BCD program select
C .................Kill
D .................Stop
E .................Pause/Continue
F .................User fault
G .................<RESERVED>
H .................Trigger Interrupt for position capture or registration (trigger inputs only). Special
trigger functions can be assigned with the TRGFN command (see page 166).
I .................Cause an “Alarm Event” over the Ethernet interface
J .................Jog in the positive-counting direction
K .................Jog in the negative-counting direction
L .................Jog velocity select
M .................Joystick release
O .................Joystick velocity select
P .................One-to-one program select
Q .................Program security
R .................End-of-travel limit for positive-counting direction *
S .................End-of-travel limit for negative-counting direction *
T .................Home limit *
* Limit inputs are factory-set to their respective end-of-travel or home limit function (see page 74).
NOTES
• Multi-tasking: If the LIMFNC or INFNC command does not include the task identifier (%) prefix,
the function affects the task that executes the LIMFNC or INFNC command. The only functions
that may be directed to a task with % are: C, D, E, F, and P (e.g., 2%INFNC3-F assigns onboard
input 3 as a user fault input for task 2). Multiple tasks may share the same input, but the input
may only be assigned one function.
Input Status
* The purpose of the IN
and LIM operators is to
use the state of the inputs
as a basis for conditional
statements (IF, REPEAT,
WHILE, GOWHEN, etc.) or
for binary variable
assignments (VARB). For
examples, refer to the
Conditional Looping and
Branching section on
page 25.
Below is a list of the status commands you may use to ascertain the current state and/or defined
function of the limit inputs (LIMFNC) and trigger and I/O brick inputs (INFNC).
Limit inputs (LIMFNC):
• Status display commands:
- LIMFNC .............. Active state and programmed function of all limit inputs
- LIMFNCi............ Same as LIMFNC display, but only for the input number (“i”)
- TLIM................... Hardware state of all limit inputs (binary report);
use TLIM.i to check the state of only one input (“i”)
• Status assignment/comparison operator: *
- LIM ..................... Hardware state (binary) of all limit inputs;
use LIM.i to check the state of only one input (“i”)
Trigger inputs and digital inputs on expansion I/O bricks (INFNC):
• Status display commands:
- TIO ..................... I/O brick configuration (which SIMs are present)
- INFNC ................ Active state and programmed function of all trigger inputs
- INFNCi .............. Same as INFNC display, but only for the trigger input number (“i”)
- <B>INFNC ......... Active state and programmed function of all inputs on I/O brick B
- <B>INFNCi....... Same as INFNC display, but only for the input number (“i”) on brick B
- TIN ..................... Hardware state of all onboard trigger inputs (binary report);
use TIN.i to check the state of only one input (“i”)
- <B>TIN .............. Hardware state of all digital inputs on I/O brick B (binary report) ;
use <B>TIN.i to check the state of only one input (“i”) on brick B
• Status assignment/comparison operator: *
- <B>IN ................ Hardware state (binary) of triggers and expansion digital inputs;
use <B>IN.i to check the state of only one input (“i”) on brick B
Chapter 3. Basic Operation Setup
95
www.comoso.com
Input Active Levels
Many people refer to a voltage level when referencing the state of programmable inputs and
outputs. Using LIMLVL (for limit inputs) and INLVL (for triggers and I/O brick inputs), you
can define the logic levels of the programmable inputs as positive or negative. The Gem6K
product defaults to an input level of zero volts as its active level (referred to as “active low”);
thus, a “1” will appear in a status command (TLIM & LIM, or TIN & IN) referencing an input
state when the voltage level is zero volts.
Active Level Setting
State
LIM/TLIM or IN/TIN Report
Active Low, the default setting
• LIMLVL0 for limits
• INLVL0 for triggers/I/O bricks
Grounded — sinking current
(device drive the input is on)
-----------------------------------------------Not Grounded — not sinking current
(device drive the input is off)
Grounded — sinking current
(device drive the input is on)
-----------------------------------------------Not Grounded — not sinking current
(device drive the input is off)
1 (active)
Active High
• LIMLVL1 for limits
• INLVL1 for triggers/I/O bricks
Input Debounce
Time
-------------------------------------0 (inactive)
0 (inactive)
-------------------------------------1 (active)
Using the INDEB command, you can change the input debounce time for programmable
inputs. The debounce is the period of time that the input must be held in a certain state before
the controller recognizes it. This directly affects the rate at which the inputs can change state
and be recognized. The default setting is 4 ms. For example, to set the debounce for all digital
inputs on I/O brick 2 to 5 ms, use the 2INDEB6 command.
Exception for Trigger Inputs: For trigger inputs that are assigned the “Trigger Interrupt”
function (INFNCi-H), the debounce is instead governed by the TRGLOT setting. The TRGLOT
setting applies to all trigger inputs defined as “Trigger Interrupt” inputs. The TRGLOT debounce
time is the time required between a trigger’s initial active transition and its secondary active
transition. This allows rapid recognition of a trigger, but prevents subsequent bouncing of the
input from causing a false position capture. The default TRGLOT setting is 24 ms.
Limit Inputs. The limit inputs found on the connectors are not normally debounced; however,
if a limit is assigned a different function with the LIMFNC command (other than LIMFNCi-R,
LIMFNCi-S, or LIMFNCi-T), the input is debounced using the INDEB setting for the on-board
trigger inputs (I/O brick 0). If a I/O brick input or an onboard trigger input is assigned a limit
input function (INFNCi-R, INFNCi-S, or INFNCi-T), the input will not be debounced.
“General Purpose”
• LIMFNCi-A
• INFNCi-A
Example
96
This is the default function for INFNC inputs (onboard digital inputs and I/O brick inputs).
When an input is defined as a General Purpose input, the input is used as a standard input.
You can then use this input to synchronize or trigger program events, through the use of the
LIM or IN operator.
DEL prog1
DEF prog1
INFNC1-A
INFNC2-A
INFNC3-D
A10
V10
D5
WAIT(IN=b1XX)
GO
IF(IN=bX1)
TFB
NIF
END
Gem6K Series Programmer’s Guide
;
;
;
;
;
;
;
;
;
;
;
;
;
;
Precaution: Delete a program before defining it
Begin definition of program prog1
No function (general purpose) for input 1
No function (general purpose) for input 2
Input 3 is a stop input
Set acceleration
Set velocity
Set distance
Wait for onboard input 1
Initiate motion
If onboard input 2
Transfer feedback device position
End IF statement
End definition of program prog1
www.comoso.com
BCD Program Select
• LIMFNCi-B
• INFNCi-B
The BCD program select function allows you to execute defined
programs by activating the program select inputs.
BCD program select inputs are assigned BCD weights, with the least
weight on the smallest numbered input. The next BCD weight is
assigned to the next input defined as a BCD input. For example, the
table to the right shows the BCD weights if inputs 1-8 are configured
as program select inputs.
Input #
BCD Weight
Input 1
Input 2
Input 3
Input 4
Input 5
Input 6
Input 7
Input 8
1
2
4
8
10
20
40
80
To execute a particular program, you activate the combination of inputs to achieve the BCD
weight that corresponds to the number of the program (see note below). For example, if inputs
1-8 are defined as BCD inputs (as in the example above), activating inputs 4 and 6 would
execute program #28, activating inputs 1 and 4 would execute program #9, and so on.
Program Numbers
A program's number is determined by the order in which the program was downloaded to
the controller. The number of each program stored in the controller's memory can be
obtained through the TDIR command — refer to the number reported in front of each
program name. When selecting programs with BCD Program Select inputs, a program is
executed when the total BCD weight of the active BCD inputs equals the program's number.
Before you can execute programs using the BCD program select inputs, you must first enable
scanning with the INSELP1 command. Once enabled, the controller will continuously scan
the BCD inputs and execute the program (by number) according to the weight of the currently
active BCD inputs. After executing and completing the selected program, the controller will
scan the inputs again. NOTE: To disable scanning, enter !INSELPØ or place INSELPØ in a
program that can be selected.
The INSELP command also determines how long the BCD program select input level must
be maintained before the controller executes the program. This delay is referred to as
debounce time (but is not affected by the INDEB setting).
Example
☞
The number in front of
each program name is
the BCD weight required
to execute the program.
RESET
ERASE
DEF PROG1
TPE
END
DEF PROG2
TREV
END
DEF PROG3
TSTAT
END
INFNC1-B
INFNC2-B
INSELP1,50
TDIR
; response
;
;
;
;
;
; Return controller to power-up conditions
; Erase all programs
; Begin definition of program PROG1
; Transfer position of encoder
; End program
; Begin definition of program PROG2
; Transfer software revision
; End program
; Begin definition of program PROG3
; Transfer statistics
; End program
; Assign onboard input 1 as a BCD program select input
; Assign onboard input 2 as a BCD program select input
; Enable scanning inputs, levels must be maintained for 50ms
; Display number and name of programs stored in memory
from TDIR should be similar to following:
*1 - PROG1 USES 6 BYTES
*2 - PROG2 USES 18 BYTES
*3 - PROG3 USES 99 BYTES
*32877 OF 33000 BYTES (98%) PROGRAM MEMORY REMAINING
*500 OF 500 SEGMENTS (100%) COMPILED MEMORY REMAINING
You can now execute the programs by activating the correct combination of inputs:
• Activate digital input 1 (BCD weight of 1) to execute program #1 (PROG1)
• Activate digital input 2 (BCD weight of 2) to execute program #2 (PROG2)
• Activate digital inputs 1 & 2 (BCD weight of 3) to execute program #3 (PROG3)
Chapter 3. Basic Operation Setup
97
www.comoso.com
Kill
When an input defined as a Kill input goes active:
• LIMFNCi-C
• INFNCi-C
•
•
•
•
Motion stops (using the LHAD and LHADA decel rate).
Program currently in progress is terminated.
Commands currently in the command buffer are eliminated.
Drive is left in the enabled state (@DRIVE1), unless the “disable drive on kill” function
is enabled with the KDRIVE command (see description on page 66).
• If error-checking bit 6 is enabled (e.g., ERROR.6-1), the error status is reported by bit
6 of the TERF, TER and ER commands and the error program (assigned with the
ERRORP command) will be executed to respond to the error condition.
NOTE: Kill is not intended as a means to temporarily inhibit motion; use the Pause/Continue
input function instead (LIMFNCi-E or INFNCi-E).
Stop
• LIMFNCi-D
• INFNCi-D
An input defined as a Stop input will stop motion (see examples below). Deceleration is
controlled by the programmed AD/ADA deceleration ramp. If error-checking bit 8 is enabled
(e.g., ERROR.8-1), the error status is reported by bit 8 of the TERF, TER and ER commands
and the error program (assigned with the ERRORP command) will be executed to respond to
the error condition.
After the Stop input is received, further program execution is dependent upon the COMEXS
command setting:
COMEXSØ: (default setting) Upon receiving a stop input, motion will stop, program
execution will be terminated and cannot be resumed, and every command in the
buffer will be discarded.
COMEXS1: Upon receiving a stop input, motion will stop, program execution will pause, and
all commands following the command currently being executed will remain in
the command buffer (but the move in progress will not be saved).
You can resume program execution (but not the move in progress) by issuing an
immediate Continue (!C) command or by activating a pause/resume input (i.e., a
general-purpose input configured as a pause/continue input with the INFNCi-E
command—see below). You cannot resume program execution while the move
in progress is decelerating.
COMEXS2: Upon receiving a stop input, the Gem6K responds as it does in the COMEXS0
mode, with the exception that you can still use the program-select inputs to
select programs (INSELP value is retained). The program-select input functions
are: BCD select (INFNCi-B or LIMFNCi-B; see page 97), and one-to-one select
(INFNCi-P or LIMFNCi-P; see page 103). For further details on program
selection with inputs, refer to INFNC (or LIMFNC) and INSELP.
Example: The 3INFNC2-D command assigns the “stop” function to the 2nd input on SIM1 of
I/O brick #3. When this input is activated, motion will stop.
98
Gem6K Series Programmer’s Guide
www.comoso.com
Pause/Continue
• LIMFNCi-E
• INFNCi-E
An input defined as a Pause/Continue input will affect motion and program execution
depending on the COMEXR command setting, as described below. In both cases, when the
input is activated, the current command being processed will be allowed to finish executing
before the program is paused.
COMEXRØ: Upon receiving a pause input, only program execution will be paused; any motion
in progress will continue to its predetermined destination. Releasing the pause
input or issuing a !C command will resume program execution.
COMEXR1: Upon receiving a pause input, both motion and program execution will be paused;
the motion stop function is used to halt motion. Releasing the pause input or
issuing a !C command will resume motion and program execution. You cannot
resume program execution while the move in progress is decelerating.
User Fault
• LIMFNCi-F
• INFNCi-F
An input defined as a User Fault input acts as an immediate Kill (!K) command, stopping
motion and terminating program execution. Motion is stopped at the rate set with the hard limit
(LHAD & LHADA) commands.
If error-checking bit #7 is enabled (e.g., ERROR.7-1), then a user fault input will cause a
branch to the ERRORP error program (for more information, see Error Handling on page 30)
and the occurrence of a user fault input will be reported by error bit #7 (see TERF, TER and ER
commands).
Trigger Interrupt
(INFNCi-H)
This function is available only for onboard trigger inputs. Any trigger input may be defined
as a Trigger Interrupt input and can be used for these functions:
• Position Capture (see below)
• Special trigger functions assigned with the TRGFN command (see below)
• Registration (see discussion on page 159)
Notes About Trigger Interrupt Inputs
• The trigger interrupt input is debounced for 24 ms (default) before another input on the
same trigger is recognized. If your application requires a different debounce time, you can
change it with the TRGLOT command (refer to Input Debounce Time on page 96).
• When configured as Trigger Interrupts, the triggers cannot be affected by the input enable
(INEN) command.
• Status: Use the TTRIG and TRIG commands to ascertain if a trigger interrupt input has
been activated. TTRIG displays the status as a binary report, and TRIG is an
assignment/comparison operator for using the status information in a conditional
expression (e.g., in an IF statement). Each TTRIG/TRIG bit is cleared when the
respective captured position value is read with the PCC, PCE, PCME, PCMS, TPCC, TPCE,
TPCME, or TPCMS commands, but the position information is still available from the
respective register until it is overwritten by a subsequent position capture by the same
trigger input.
Position Capture
The Gem6K has two dedicated trigger inputs, referred to as “TRIG-A” and “TRIG-B.” These
trigger inputs are located on the DRIVE/10 connector. When either trigger input (TRIG-A or
TRIG-B) is assigned the Trigger Interrupt function, activating the input performs a hardware
capture of the position. If the Gem6K is used as a follower in Following, activating the trigger
also performs an interpolated capture of the associated master axis position.
An additional trigger, labeled “TRIG-M”, may be used to perform a hardware capture of the
Master Encoder (the encoder connected to the “MASTER ENCODER” connector), as well as the
motor position (encoder position on servo axes; commanded or encoder position for steppers,
depending on the ENCCNT setting). To assign TRIG-M as a trigger interrupt input, use the
Chapter 3. Basic Operation Setup
99
www.comoso.com
INFNC17-H command.
When a Trigger Interrupt input is activated, the controller captures the relevant positions and
stores them in registers that are available at the next system update (2 ms) through the use of
these transfer and assignment/comparison commands:
Captured Information
Commanded position
Encoder position
Master encoder position
Master cycle position
Transfer
TPCC
TPCE
TPCME
TPCMS
Assignment/Comparison
PCC
PCE
PCME
PCMS
Offset *
PSET
PSET
PMESET
PSET
Scale Factor **
SCLD
SCLD
SCLMAS
SCLMAS
* Captured values are offset by any existing PSET or PMESET offset.
** If scaling is enabled, the captured position is scaled by SCLD or SCLMAS.
Notes About Position Capture
• Hardware Capture: The encoder position is captured within ± 1 encoder count. The
commanded position capture accuracy is ± 1 count.
• Interpolated Capture: There is a time delay of up to 50 µs between activating the trigger
interrupt input and capturing the position; therefore, the accuracy of the captured position
is equal to 50 µs multiplied by the velocity at the time the input was activated.
• Servo vs. Stepper. The nature of the position captured with a Trigger Interrupt input may
be different, depending on whether the drive is a servo or stepper. For servos, both the
commanded and encoder positions are captured. Analog input feedback cannot be
captured. For steppers, if the ENCCNT command is set to ENCCNT0 (default condition),
only the commanded position is captured. If ENCCNT1 mode is enabled, only the encoder
position is captured.
Trigger Functions
The Trigger Functions command (TRGFN) allows you to assign additional functions to trigger
inputs that have been defined as trigger interrupt inputs with the INFNCi-H command. These
trigger functions are cleared once the function is triggered. Command syntax is:
TRGFNcbb
Start New Master Cycle (FMCNEW) function
Conditional GO (GOWHEN) function
Trigger letter. Two triggers are available (A or B).
The “Master Trigger” (letter M) may also be used.
• “Conditional GO” Function (TRGFNc1x): Suspend execution of the next start-motion
command until the specified trigger input goes active. Start-motion commands are:
- GO (standard command to begin motion)
- FSHFC (begin continuous shift – for Following motion)
- FSHFD (begin preset shift – for Following motion)
Axis status bit #26 (reported with TASF, TAS, or AS) is set to one (1) when there is a
pending “Conditional GO” condition initiated by a TRGFN command; this bit is cleared
when the trigger is activated or when a stop command or a kill command is issued. If you
need execution to be triggered by other factors (e.g., input state, master position, encoder
position, etc.) use the GOWHEN command; refer to GOWHEN command or page 163 for
details.
• “New Master Cycle” Function (TRGFNcx1): This is equivalent to executing the
FMCNEW command. When the specified trigger input goes active, the controller begins
a new Following master cycle. Refer to the FMCNEW command or to page 183 for
more on master cycles.
100
Gem6K Series Programmer’s Guide
www.comoso.com
Code Examples
INFNC1-H
INFNC2-H
TRGFNAx1
TRGFNB1
GO
Registration
;
;
;
;
;
;
;
;
;
Assign trigger A (onboard input 1) to function as
a trigger interrupt input.
Assign trigger B (onboard input 2) to function as
a trigger interrupt input.
When trigger A goes active, begin a new master cycle
When trigger B goes active, execute the move commanded
with the GO command.
The move is commanded, but will not execute until
trigger B becomes active.
If registration is enabled (with the RE command), activating a trigger interrupt input will
initiate a registration move defined with the REG command. Refer to page 159 for details on
the Registration feature.
Alarm Event
• LIMFNCi-I
• INFNCi-I
An input specified as an Alarm Event input will cause the Gem6K controller to set an Alarm
Event in the Communications Server over the Ethernet interface. You must first enable the
Alarm checking bit for this input-driven alarm (INTHW.23-1). For details on using alarms
and other Communications Server features, refer to the COM6SRVR Programmer’s Guide or to
the Motion Planner help system.
Jogging the Motor
In some applications, you may want to manually move (jog) the load. You can configure these
jog-related input functions:
•
•
•
•
•
•
LIMFNCi-J
LIMFNCi-K
LIMFNCi-L
INFNCi-J
INFNCi-K
INFNCi-L
“J” ....Jog in the positive counting direction when the input is active, stop when the input is
inactive.
“K” ....Jog in the negative counting direction when the input is active, stop when the input is
inactive.
“L” ....Select the high (JOGVH) or low (JOGVL) velocity setting for jog motion. Activating
the input selects high velocity, deactivating the input selects low velocity.
The jog profile is defined with these commands listed below. NOTE: If scaling is enabled
(SCALE1) the velocity is scaled by SCLV and accel/decel is scaled by SCLA.
JOGVH....... High velocity range for jogging. The high velocity is used when the jogging
speed-select input (configured with INFNCi-L) is active.
JOGVL....... Low velocity range for jogging. The low velocity is used when the jogging
speed-select input (configured with INFNCi-L) is inactive.
JOGA ......... Jog acceleration
JOGAA....... Jog acceleration (s-curve profile)
JOGAD....... Jog deceleration
JOGADA .... Jog deceleration (s-curve profile)
Once you set up the jog functions and move profile, you can attach a switch to the designated
jog inputs and perform jogging. (Jog motion will not occur unless Jog Mode is enabled with
the JOG command.) The example below shows you how to define a program to set up jogging.
Chapter 3. Basic Operation Setup
101
www.comoso.com
Example
Step 1
Define program for jog setup:
DEF prog1
JOGA25
JOGAD25
JOGVL.5
JOGVH5
INFNC1-J
INFNC2-K
INFNC3-L
JOG1
END
;
;
;
;
;
;
;
;
;
;
Begin definition of program prog1
Jog acceleration to 25 units/sec/sec
Jog deceleration to 25 units/sec/sec
Low-speed jog velocity to 0.5 units/sec
High-speed jog velocity to 5 units/sec
Trigger input 1 is a positive-direction jog input, axis 1
Trigger input 2 is a negative-direction jog input, axis 1
Trigger input 3 is a speed-select input, axis 1
Enable Jog function for axis 1
End program definition
Step 2
Download and run the prog1 program.
Step 3
Activate input 1 to move the load in the positive direction at a velocity of 0.5 units/sec (until
trigger input 1 is released). Deactivate the input to stop the axis.
Step 4
Activate input 2 to move the load in the negative direction at a velocity of 0.5 units/sec (until
input 2 is released). Deactivate the input to stop the axis.
Step 5
Activate input 3 to switch to high-speed jogging.
Step 6
Repeat steps 3 and 4 to perform high-speed jogging at the JOGVH value (5 rps).
Joystick Functions
• LIMFNCi-M
• LIMFNCi-N
• LIMFNCi-O
• INFNCi-M
• INFNCi-N
• INFNCi-O
As part of the joystick setup process, you can configure programmable inputs to serve the
joystick input functions listed below. Full details on joystick setup and operation are provided
on page 130.
“M” ....The Joystick Release input signals the controller to end joystick operation and resume
program execution with the next statement in your program. When the input is open
(high, sinking current), the joystick mode is disabled (joystick mode can be enabled
only if the input is closed, and only with the JOY command). When the input is closed
(low, not sinking current), joystick mode can be enabled with the JOY command. The
general process of using Joystick mode is:
1. Assign the “Joystick Release” input function to a programmable input.
2. At the appropriate place in the program, enable joystick control of motion (with the JOY
command). (Joystick mode cannot be enabled unless the "Joystick Release" input is
closed.) When the JOY command enables joystick mode, program execution stops
(assuming the Continuous Command Execution Mode is disabled with the COMEXCØ
command).
3. Use the joystick to move as required.
4. When you are finished using the joystick, open the “Joystick Release” input to disable the
joystick mode. This allows program execution to resume with the next statement after the
initial JOY command that started the joystick mode.
“O” ...The Joystick Velocity Select input allows you to select the velocity for joystick
motion. The JOYVH and JOYVL commands establish the high-speed velocity and the
low-speed velocity, respectively. Opening the Velocity Select input (input is high,
sinking current) selects the JOYVH configuration. Closing the Velocity Select input
(input is low, not sinking current) selects the JOYVL configuration. The high range
could be used to quickly move to a location, the low range could be used for accurate
positioning. NOTE: When this input is not connected, joystick motion always uses
the JOYVL velocity setting.
102
Gem6K Series Programmer’s Guide
www.comoso.com
One-to-One
Program Select
• LIMFNCi-iP
• INFNCi-iP
An input defined as a One-to-One Program Select input is assigned to execute one specific
program. The targeted program is reference by its number (see note).
Program Numbers
A program’s number is determined by the order in which the program was downloaded to the
controller. The number of each program stored in the controller's memory can be obtained
through the TDIR command — refer to the number reported in front of each program name.
When selecting programs with One-to-One Program Select inputs, the program number is
assigned to one specific input and is executed when the input is activated (see example
below).
Before you can execute programs using the One-to-One program select inputs, you must first
enable scanning with the INSELP2 command. Once enabled, the controller will continuously
scan the inputs and execute the program (by number) according to the program number
assigned to the input. After executing and completing the selected program, the controller will
scan the inputs again. NOTE: To disable scanning, enter !INSELPØ or place INSELPØ in a
program that can be selected.
The INSELP command also determines how long the program select input level must be
maintained before the controller executes the program. This delay is referred to as debounce
time (but is not affected by the INDEB setting).
Example
RESET
DEF proga
TFB
END
DEF progb
TREV
END
DEF progc
TSTAT
END
TDIR
INFNC4-1P
INFNC5-2P
INFNC6-3P
INSELP2,50
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
Return controller to power-up default conditions
Begin definition of program proga
Transfer position of feedback devices
End program
Begin definition of program progb
Transfer software revision
End program
Begin definition of program progc
Transfer statistics
End program
Response should show:
*1 - PROGA USES 36 BYTES
*2 - PROGB USES 70 BYTES
*3 - PROGC USES 133 BYTES
input 4 will select proga
input 5 will select progb
input 6 will select progc
Enable scanning of inputs with a strobe time of 50 ms
You can now execute programs by making a contact closure from an input to ground to
activate the input:
• Activate input #4 to execute program #1 (proga)
• Activate input #5 to execute program #2 (progb)
• Activate input #6 to execute program #3 (progc)
Chapter 3. Basic Operation Setup
103
www.comoso.com
Program Security
• LIMFNCi-Q
• INFNCi-Q
Once an input is assigned the Program Security function, the Program Security feature is
enabled. The program security feature denies you access to the DEF, DEL, ERASE, MEMORY,
LIMFNC and INFNC commands until you activate the Program Security input. Being denied
access to these commands effectively restricts altering the user memory allocation. If you try
to use these commands when program security is active (program security input is not
activated), you will receive the error message *ACCESS DENIED.
For example, once you issue the 2INFNC7-Q command, input #7 on I/O brick #2 (2IN.7) is
assigned the program security function and access to the DEF, DEL, ERASE, MEMORY,
LIMFNC and INFNC commands will be denied until you activate 2IN.7.
To regain access to the DEF, DEL, ERASE, MEMORY, LIMFNC or INFNC commands without
the use of the program security input, you must issue the INEN command to disable the
program security input, make the required user memory changes, and then issue the INEN
command to re-enable the input. For example, if input 3 on brick 2 is assigned as the Program
Security input, use 2INEN.3=1 to disable the input and leave it activated, make the necessary
user memory changes, and then use 2INEN.3=E to re-enable the input.
NOTE: If you wish the Program Security feature to be enabled on power-up, place the
INFNCi-Q or LIMFNCi-Q command in the start-up program (STARTP).
Limit Functions
• LIMFNCi-aR
• LIMFNCi-aS
• LIMFNCi-aT
• INFNCi-aR
• INFNCi-aS
• INFNCi-aT
Input numbers are factory-configured with the LIMFNC command to function as end-of-travel
and home limits (see illustration on page 91). The limit functions are:
“R” .... Positive-Direction End-of-Travel Limit input, axis specific.
“S” .... Negative-Direction End-of-Travel Limit input, axis specific.
“T” .... Home Limit input, axis specific.
If you intend to use digital inputs on an external I/O brick as limit inputs:
1. Assign the limit function to the external input with the INFNC command. For example,
1INFNC9-1R assigns the “axis 1 positive end-of-travel limit” function to the 1st input
on SIM2 (I/O point 9) of I/O brick 1.
2. Reassign the respective “LIMITS” input to a non-limit function with the LIMFNC
command. For example, LIMFNC1-A assigns the “general-purpose input” function to
limit input 1 (normally assigned the “axis 1 positive end-of-travel limit” function).
NOTE: Once an input or I/O brick input is assigned a limit function, it is no longer debounced
(INDEB has no effect), and it must be enabled/disabled with the LH command instead of the
INEN command.
104
Gem6K Series Programmer’s Guide
www.comoso.com
Output Functions
The Gem6K product provides programmable digital outputs, found on the drive I/O connect.
Additional digital outputs may be installed on expansion I/O bricks (see example on page 93).
You can turn the controller's programmable outputs on and off with the Output (OUT, POUT
or OUTALL) commands, or you can use the Output Function (OUTFNC) command to
configure them to activate based on seven different situations. The OUTFNC syntax is as
follows:
<B>OUTFNCi-c
I/O Brick number.
Onboard outputs are considered
collectively as I/O brick 0 (zero), and
are addressed of the I/O brick
number is left off the command.
Letter that selects the desired
function (see list below).
Number of the output.
(see page 78-79 for output bit assignments)
Letter Designator
Function
A .................General-purpose output (default function)
<a>B .................Moving/not moving
C .................Program in progress
<a>D .................Hardware or software end-of-travel limit encountered
<a>E .................Stall indicator — stepper only
F .................Fault indicator (indicates drive fault input or user fault input is active)
G .................Position error exceeds max. limit set with SMPER — servo only
H .................Output on position
NOTES
• Multi-tasking: If the OUTFNC command does not include the task identifier (%) prefix, the
function affects the task that executes the OUTFNC command. “Program in progress”
(function C) is only function that may be directed to a specific task with %. Multiple tasks
may share the same output, but the output may only be assigned one function.
• Limit of 32 output functions: You may assign a maximum of 32 OUTFNC functions. This
excludes function A (“general-purpose”).
Chapter 3. Basic Operation Setup
105
www.comoso.com
Output Status
Below is a list of the status commands you may use to ascertain the current state and/or defined
function of the outputs.
• Status display commands:
- TIO........................I/O brick configuration (which SIMs are present, including sinking/sourcing)
- OUTFNC.................Active state and programmed function of all onboard outputs
- OUTFNCi ..............Same as OUTFNC display, but only for the output number (“i”)
- <B>OUTFNC..........Active state and programmed function of all outputs on I/O brick B
- <B>OUTFNCi .......Same as OUTFNC display, but only for the output number (“i”) on I/O brick B
- TOUT .....................Hardware state of all onboard outputs (binary report);
use TOUT.i to check the state of only one output (“i”)
- <B>TOUT ..............Hardware state of all outputs (binary report) on I/O brick B;
use <B>TOUT.i to check the state of only one output (“i”) on brick B
• Status assignment/comparison operator: *
- OUT........................Hardware state (binary) of all onboard outputs;
use OUT.i to check the state of only one output (“i”)
- <B>OUT.................Hardware state (binary) of all outputs on I/O brick B;
use <B>OUT.i to check the state of only one output (“i”) on I/O brick B
* The purpose of the OUT operator is to use the state of the outputs as a basis for conditional
statements (IF, REPEAT, WHILE, GOWHEN, etc.) or for binary variable assignments (VARB).
Output Active
Levels
Using OUTLVL, you can define the logic levels of the programmable outputs as positive or
negative. OUTLVL0 selects active low (default setting); OUTLVL1 selects active high.
Onboard Digital Outputs
OUTLVL Setting
OUTLVL0 (default)
OUTLVL0 (default)
OUTLVL1
OUTLVL1
OUT State *
OUT1
OUT0
OUT1
OUT0
Current
Sinking current
No current flow
No current flow
Sinking current
TOUT Status
1
0
1
0
* The output is “active” when it is commanded by the OUT, OUTPA, or POUTA commands
(for example, OUTxx1 activates output #3).
Outputs on Expansion I/O Bricks:
• Sinking vs. Sourcing Outputs. On power up, the Gem6K controller auto-detects the type
of output SIM installed on each external I/O brick, and automatically changes the OUTLVL
setting accordingly. If sinking (NPN) outputs are detected, OUTLVL is set to active low
(OUTLVL0); if sourcing (PNP) outputs are detected, OUTLVL is set to active high
(OUTLVL1).
• Disconnect I/O Brick. If the I/O brick is disconnected (or if it loses power), the controller
will perform a kill (all tasks) and set error bit #18. (If you disable the “Kill on I/O
Disconnect” mode with KIOENØ, the Gem6K will not perform the kill.) The controller
will remember the brick configuration (volatile memory) in effect at the time the
disconnection occurred. When you reconnect the I/O brick, the controller checks to see if
anything changed (SIM by SIM) from the state when it was disconnected. If an existing
SIM slot is changed (different SIM, vacant SIM slot, or jumper setting), the controller
will set the SIM to factory default INEN and OUTLVL settings. If a new SIM is installed
where there was none before, the new SIM is auto-configured to factory defaults.
106
Gem6K Series Programmer’s Guide
www.comoso.com
• Relationships:
Output Type
OUTLVL Setting
NPN (sinking)
NPN
NPN
NPN
PNP (sourcing)
PNP
PNP
PNP
OUTLVL0 (default)
OUTLVL0 (default)
OUTLVL1
OUTLVL1
OUTLVL0
OUTLVL0
OUTLVL1 (default)
OUTLVL1 (default)
OUT State *
OUT1
OUT0
OUT1
OUT0
OUT1
OUT0
OUT1
OUT0
Current
Sinking current
No current flow
No current flow
Sinking current
No current flow
Sourcing current
Sourcing current
No current flow
OUT/TOUT status
1
0
1
0
1
0
1
0
LED
ON
OFF
OFF
ON
OFF
ON
ON
OFF
* The output is “active” when it is commanded by the OUT, OUTP, or POUT command
(for example, OUTxx1 activates output #3).
“General Purpose”
(OUTFNCi-A)
Moving/Not Moving
(In Position)
(OUTFNCi-B)
The default function for the outputs is General Purpose. As such, the output is used as a
standard output, turning it on or off with the OUT, OUTP or OUTALL commands to affect
processes external to the controller. To view the state of the outputs, use the TOUT command.
To use the state of the outputs as a basis for conditional branching or looping statements (IF,
REPEAT, WHILE, etc.), use the [ OUT ] command.
When assigned the Moving/Not Moving function, the output will activate when motion is
commanded. As soon as the move is completed, the output will change to the opposite state.
Servos: If the target zone mode is enabled (STRGTE1), the output will not change state until
the move completion criteria set with the STRGTD and STRGTV commands has been met.
(For more information, refer to the Target Zone section on page 84.) In this manner, the
Moving/Not Moving output functions as an In Position output.
Example
The code example below defines onboard outputs 1 and 2 as General Purpose outputs and
output 3 as a Moving/Not Moving output. Before the motor moves 4,000 steps, output 1 turns
on and output 2 turns off. These outputs remain in this state until the move is completed, then
output 1 turns off and output 2 turns on. While the motor/load is moving, output 3 remains on.
SCALE0
MC0
MA0
A10
V5
D4000
OUTFNC1-A
OUTFNC2-A
OUTFNC3-B
OUT10
GO
OUT01
Program in
Progress
(OUTFNCi-C)
;
;
;
;
;
;
;
;
;
;
;
;
Disable scaling
Set axis 1 to preset positioning mode
Select incremental positioning mode
Set axis 1 acceleration to 10
Set axis 1 velocity to 5
Set axis 1 distance to 4,000 counts
Set onboard output 1 as a general purpose output
Set onboard output 2 as a general purpose output
Set onboard output 3 as axis 1 Moving/Not Moving output
Turn onboard output 1 on and output 2 off
Initiates axis 1 move
Turn onboard output 1 off and output 2 on
When assigned the Program in Progress function, the output will activate when a program is
being executed. After the program is finished, the output's state is reversed. The action of
executing a program is also reported with system status bit 3 (see TSSF, TSS and SS
commands).
Chapter 3. Basic Operation Setup
107
www.comoso.com
Limit Encountered
(OUTFNCi-D)
When assigned the Limit Encountered function, the output will activate when a hard or soft
end-of-travel limit has been encountered.
If a hard or soft limit is encountered, you will not be able to move the motor/load in that same
direction until you clear the limit by changing direction (D) and issuing a GO command. (An
alternative is to disable the limits with the LHØ command, but this is recommended only if the
motor is not coupled to the load.) The event of encountering an end-of-travel limit is also
reported with axis status bits 15-18 (see TASF, TAS and AS commands, summary on page 222).
Stall Indicator
(OUTFNCi-E)
Stepper Axis Only
Fault Output
When assigned the Stall Indicator function, the output will activate when a stall is detected. To
detect a stall, you must first connect an encoder and enable stall detection with the ESTALL1
command. Refer to Encoder-Based Stepper Operation on page 84 for further discussion on
stall detection.
(OUTFNCi-F)
When assigned the Fault Output function, the output will activate when either the user fault
input or the drive fault input becomes active. The user fault input is a general-purpose input
defined as a user fault input with the LIMFNCi-F or INFNCi-F command (see page 99).
Maximum Position
Error Exceeded
When assigned the Max. Position Error Exceeded function, the output will activate when the
maximum allowable position error, as defined with the SMPER command, is exceeded.
(OUTFNCi-G)
Servos Only
The position error (TPER) is defined as the difference between the commanded position (TPC)
and the actual position as measured by the feedback device (TFB). When the maximum
position error is exceeded (usually due to lagging load, instability, or loss of position
feedback), the controller shuts down the drive and sets error status bit #12 (reported by the
TERF, TER and ER commands if bit #12 of the ERROR command is enabled).
NOTE
If the SMPER command is set to zero (SMPERØ — the default value), the position error will not
be monitored; thus, the Maximum Position Error Exceeded function will not be usable.
108
Gem6K Series Programmer’s Guide
www.comoso.com
Output on Position
(OUTFNCi-H)
The Output on Position feature activates the designated output when the motor or load has
reached a specified position. To use this feature, you must first assign the Output on Position
function to output #1, and define the Output on Position characteristics with the OUTP
command. Note: this is a firmware feature (not hardware) and the output on position is
only updated every 1msec.
OUTPA
Enable Bit:
<b>, <b>, <r>, <i>
Time (milliseconds):
1 ... Enable the output-on-position function
0 ... Disable the output-on-position function
Servo Axes: If an SFB command is executed,
the function is disabled.
Time (milliseconds) the output is to stay active.
The output activates when the specified
position (<r>) is reached or exceeded, and
stays active for the specified time.
Increment or Absolute Position Comparison:
If this field is set to zero, the output will stay
active for as long as the actual distance equals
or exceeds the position comparison distance
(this is possible only for an absolute position
comparison).
1 ... Set position comparison to incremental
...... (measured from the last start-motion
...... command, such as GO, GOWHEN, etc.)
0 ... Set position comparison to absolute
Position:
Scalable distance (distance is either
incremental or absolute, depending on the
second <b> data field).
Servos: Only the encoder position can be used.
Steppers:
If ENCCNT0, commanded position is used.
If ENCCNT1, encoder position is used.
Sample Code
for Setup
In this example, the user wants to turn on output when the motor (servo) reaches encoder
position 50,000. The output must remain on for 50 milliseconds.
OUTFNC1-H
OUTP1,0,+50000,50
;
;
;
;
;
;
;
;
;
Define axis 1 as servo, axis 2 as stepper
Select encoder feedback for axis 1
Define onboard output #1 as an "output on
position" output
Define onboard output #2 as an "output on
position" output
Turn on onboard output #1 for 50 ms when the
encoder position is > or =
absolute position +50,000
Notes about Output On Position
• On servos, this feature can be used only with encoder feedback and is not operational with
ANI (analog input) feedback.
On steppers, this feature can be based on commanded position or encoder position,
depending on the ENCCNT setting (default is ENCCNT0, which uses the commanded
position).
• The output activates only during motion; thus, issuing a PSET command to set the
absolute position counter to activate the output on position will not turn on the output until
the next motion occurs.
Chapter 3. Basic Operation Setup
109
www.comoso.com
Variable Arrays (teaching variable data)
More on variables:
see page 18.
Variable data arrays provide a method of storing (teaching) variable data and later using the
stored data as a source for motion program parameters. The variable data can be any value that
can be stored in a numeric (VAR or VARI) variable (e.g., position, acceleration, velocity, etc.).
The variable data is stored into a data program, which is an array of data elements that have a
specific address from which to write and read the variable data. Data programs do not contain
Gem6K Series commands.
The information below describes the principles of using the data program in a teach-type
application. Following that is an application example in which the joystick is used to teach
position data to be used in a motion program.
Basics of Teach-Data Applications
The basic process of using a data program for data teaching applications is as follows:
1. Initialize a data program.
2. Teach (store/write) variable data into the data program.
3. Read the data elements from the data program into a motion program.
1. Initialize a
Data Program
This is accomplished with the DATSIZ command. The DATSIZ command syntax is
DATSIZi<,i>. The first integer (i) represents the number of the data program (1 - 50). You
can create up to 50 separate data programs. The data program is automatically given a specific
program name (DATPi). The second integer represents the total number of data elements (up
to 6,500) you want in the data program. Upon issuing the DATSIZ command, the data program
is created with all the data elements initialized with a value of zero.
The data program has a tabular structure, where the data elements are stored 4 to a line. Each
line of data elements is called a data statement. Each element is numbered in sequential order
from left to right (1 - 4) and top to bottom (1 - 4, 5 - 8, 9 - 12, etc.). You can use the TPROG
DATPi command (“i” represents the number of the data program) to display all the data
elements of the data program.
For example, if you issue the DATSIZ1,13 command, data program #1 (called DATP1) is
created with 13 data elements initialized to zero. The response to the TPROG DATP1
command is depicted below. Each line (data statement) begins with DATA=, and each data
element is separated with a comma.
*DATA=+Ø.Ø,+Ø.Ø,+Ø.Ø,+Ø.Ø
*DATA=+Ø.Ø,+Ø.Ø,+Ø.Ø,+Ø.Ø
*DATA=+Ø.Ø,+Ø.Ø,+Ø.Ø,+Ø.Ø
*DATA=+Ø.Ø
Each data statement, comprising four data elements, uses 43 bytes of memory. The memory
for each data statement is subtracted from the memory allocated for user programs (see
MEMORY command).
110
Gem6K Series Programmer’s Guide
www.comoso.com
2. Teach the Data
to the Data
Program
The data that you wish to write to the data elements in the data program must first be placed
into numeric variables (VAR). Once the data is stored into numeric variables, the data elements
in the data program can be edited by using the Data Pointer (DATPTR) command to move the
data pointer to that element, and then using the Data Teach (DATTCH) command to write the
datum from the numeric variable into the element.
When the DATSIZ command is issued, the internal data pointer is automatically positioned to
data element #1. Using the default settings for the DATPTR command, the numberic variable
data is written to the data elements in sequential order, incrementing one by one. When the
last data element in the data program is written, the data pointer is automatically set to data
element #1 and a warning message (*WARNING: POINTER HAS WRAPPED AROUND
TO DATA POINT 1) is displayed. The warning message does not interrupt program
execution.
The DATPTR command syntax is DATPTRi,i,i. The first integer (i) represents the data
program number (1 through 50). The second integer represents the number of the data element
to point to (1 through 6500). The third integer represents the number of data elements by
which the pointer will increment after writing each data element from the DATTCH command,
or after recalling a data element with the DAT command.
The DATTCH command syntax is DATTCHi<,i,i,i>. Each integer (i) represents the
number of a numeric variable. The value of the numeric variable will be stored into the data
element(s) of the currently active data program (i.e., the program last specified with the last
DATSIZ or DATPTR command). As indicated by the number of integers in the syntax, the
maximum number of variable values that can be stored in the data program per DATTCH
command is 4. Each successive value from the DATTCH command is stored to the data
program according to the pattern established by the third integer of the DATPTR command.
As an example, suppose data program #1 is configured to hold 13 data elements
(DATSIZ1,13), the data pointer is configured to start at data element #1 and increment 1
data element after every value stored from the DATTCH command (DATPTR1,1,1), and the
values of numeric variables #1 through #3 are already assigned (VAR1=2, VAR2=4,
VAR3=8). If you then enter the DATTCH1,2,3 command, the values of VAR1 through VAR3
will be assigned respectively to the first three data elements in the data program, leaving the
pointer pointing to data element #4. The response to the TPROG DATP1 command would be
as follows (the text is highlighted to illustrate the final location of the data pointer after the
DATTCH1,2,3 command is executed):
*DATA=+2.Ø,+4.Ø,+8.Ø,+Ø.Ø
*DATA=+Ø.Ø,+Ø.Ø,+Ø.Ø,+Ø.Ø
*DATA=+Ø.Ø,+Ø.Ø,+Ø.Ø,+Ø.Ø
*DATA=+Ø.Ø
If you had set the DATPTR command to increment 2 data elements after every value from the
DATTCH command (DATPTR1,1,2), the data program would be filled differently and the
data pointer would end up pointing to data element #7:
*DATA=+2.Ø,+Ø.Ø,+4.Ø,+Ø.Ø
*DATA=+8.Ø,+Ø.Ø,+Ø.Ø,+Ø.Ø
*DATA=+Ø.Ø,+Ø.Ø,+Ø.Ø,+Ø.Ø
*DATA=+Ø.Ø
3. Recall the Data
from the Data
Program
After storing (teaching) your variables to the data program, you can use the DATPTR command
to point to the data elements and the DATi (“i” = data program number) data assignment
command to read the stored variables to your motion program. You cannot recall more than
one data element at a time; therefore, if you want to recall the data in a one-by-one sequence,
the third integer of the DATPTR command must be a 1 (this is the default setting).
Chapter 3. Basic Operation Setup
111
www.comoso.com
Summary of Related Gem6K Series Commands
DATSIZ ..... Establishes the number of data elements a specific data program is to contain. A
new DATPi program name is automatically generated according to the number
of the data program (i = 1 through 50). The memory required for the data
program is subtracted from the memory allocated for user programs (see
MEMORY command).
DATPTR ..... Moves the data pointer to a specific data element in any data program. This
command also establishes the number of data elements by which the pointer
increments after writing each data element from the DATTCH command and
after recalling each data element with the DAT command.
DATTCH ..... Stores the variable data into the data program specified with the last DATSIZ or
DATPTR command. After the data is stored, the data pointer is incremented the
number of times entered in the third integer of the DATPTR command. The data
must first be assigned to a numeric variable before it can be taught to the data
program.
TDPTR ....... Responds with a 3-integer status report (i,i,i): First integer is the number of
the active data program (the program # specified with the last DATSIZ or
DATPTR command); Second integer is the location number of the data element
to which the data pointer is currently pointing; Third integer is the increment set
with the last DATPTR command.
[ DPTR ] ... From the currently active data program, uses the number of the data pointer's
location in a numeric variable assignment operation or a conditional statement
operation.
[ DATPi ] . The name of the data program created after issuing the DATSIZ command. The
integer (i) represents the number of the data program. Data programs can be
deleted just like any other user program (e.g., DEL DATP1).
[ DATi ] ... From the data program specified with i, assigns the numeric value of the data
element (currently pointed to by the data pointer) to a specified variable
parameter in a Gem6K series command (e.g., D(DAT3),(DAT3)).
Teach-Data Application Example
For the sake of brevity, this example is limited to teaching 10 position data points; however,
in a typical application, many more points would be taught. Also, it is assumed that end-oftravel and home limits are wired and a homing move has been programmed.
What follows is a suggested method of programming the controller to teach I/O data points.
To accomplish the teach application, a program called MAIN is created, comprising three
subroutines: SETUP (to set up for teaching data to the data program), TEACH (to teach the
positions), and DOPATH (to implement a motion program based on the positions taught).
The joystick operation in this example is based on using an analog inputs (ANI) SIM on an
expansion I/O brick. The ANI SIM is in slot 2 of I/O brick 1 and inputs 1 and 2 are used to
control axes 1 and 2, respectively. A digital input SIM is installed in slot 1 of I/O brick 1, and
input 1 on that SIM is assigned the Joystick Release function to trigger the position teach
operation.
Step 1
Initialize a Data Program.
DEL DATP1
DATSIZ1,1Ø
112
Gem6K Series Programmer’s Guide
;
;
;
;
;
Delete data program #1 (DATP1) in preparation for
creating a new data program #1
Create data program #1 (named DATP1) with an
allocation of 10 data elements. Each element is
initialized to zero.
www.comoso.com
Step 2
Define the SETUP Subroutine. The SETUP subroutine need only run once.
DEF SETUP
1INFNC1-M
JOYVH3
JOYAXH1-9
VAR1=Ø
VAR2=Ø
DRIVE1
MA1
END
Step 3
;
;
;
;
;
;
;
;
;
;
;
;
;
Begin definition of the subroutine called SETUP
Assign digital input 1 on SIM 2 (I/O point #1) of
I/O brick 1 to function as a "Joystick Release" input.
Set the maximum velocity (3 units/sec)
achievable when the joystick is at full
deflection
Assign ANI input 1 on SIM 2 (I/O point #9) of I/O
brick 1
Initialize variable #1 equal to zero
Initialize variable #2 equal to zero
Enable the drive
Enable the absolute positioning mode
End definition of the subroutine called SETUP
Define the TEACH Subroutine.
DEF TEACH
HOM1
; Begin definition of the subroutine called TEACH
; Home the axis (absolute position counter is set to
; zero after the homing move)
DATPTR1,1,1
; Select data program #1 (DATP1) as the current active
; data program, and move the data pointer to the first
; data element. After each DATTCH value is stored to
; DATP1, increment the data pointer by 1 data element.
REPEAT
; Set up a repeat/until loop
JOY1
; Enable joystick mode. At this point,
; you can start moving into position with the
; joystick. WHILE USING THE JOYSTICK, COMMAND PROCESSING
; IS STOPPED HERE UNTIL YOU ACTIVATE THE JOYSTICK
; RELEASE INPUT. Activating the joystick release input
; disables the joystick mode and allows the subsequent
; commands to be executed (assign the current positions
; to the variables and then store the positions in the
; data program).
VAR1=1PM
; Set variable #1 equal to the position of motor 1
DATTCH1
; Store variable #1. (The first time through the
; repeat/until loop, variable #1 is stored into data ;
;element #1. The data pointer is automatically
; incremented once after each data element and ends up
;pointing to the third data element in anticipation of
;the next DATTCH command.)
WAIT(1IN.1=b1) ; Wait for the joystick release input to be de-activated
UNTIL(DPTR=1) ; Repeat the loop until the data pointer wraps around
; to data element #1 (data program full)
END
; End definition of the subroutine called TEACH
Chapter 3. Basic Operation Setup
113
www.comoso.com
Step 4
Define the DOPATH Subroutine.
DEF DOPATH
HOM1
A5Ø
V3
DATPTR1,1,1
REPEAT
D(DAT1)
GO
T.5
UNTIL(DPTR=1)
HOM1
END
Step 5
Begin definition of the subroutine called DOPATH
Move to the home position
(absolute counters set to zero)
Set up the acceleration
Set up the velocity
Select data program #1 (DATP1) as the current active
data program, and set the data pointer to the first
data element. Increment the data pointer one element
after every data assignment with the DAT command.
Set up a repeat/until loop
The position is recalled into
the distance command
Move to the position
Wait for 0.5 seconds
Repeat the loop until the data pointer wraps around
to data element #1 (all data elements have been read)
Move back to the home position
End definition of the subroutine called DOPATH
Define the MAIN Program (Include SETUP, TEACH, and DOPATH).
DEF MAIN
SETUP
TEACH
DOPATH
END
Step 6
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
Begin definition of the program called MAIN
Execute the subroutine called SETUP
Execute the subroutine called TEACH
Execute the subroutine called DOPATH
End definition of the program called MAIN
Run the MAIN Program and Teach the Positions with the Joystick.
1.
Enter the MAIN command to execute the teach application program.
2.
2.
Use the joystick to move to the position to be taught.
3. Once in position, activate the joystick release input to teach the positions.
4. Repeat steps 2 and 3 for the remaining nine teach locations. After triggering the
joystick release input the tenth time, the controller will home the motor, repeat the
path that was taught, and then return to the home position.
114
Gem6K Series Programmer’s Guide
www.comoso.com
Product Control Options
4
CHAPTER FOUR
Product Control
Options
IN THIS CHAPTER
This chapter explains various options for controlling your Gem6K product:
•
•
•
•
•
•
Safety features .................................................................................................... 116
Overview of product control options.................................................................. 116
Programmable I/O (switches, thumbwheels, PLCs, PLC Scan Mode, etc.) ................ 118
RP240 remote operator panel ............................................................................. 123
Joystick and analog input interface (requires ANI SIM on expansion I/O brick) ...... 130
Host computer interface ..................................................................................... 133
www.comoso.com
Safety Features
WARNING
The Gem6K Product is used to control your system's electrical and mechanical components.
Therefore, you should test your system for safety under all potential conditions. Failure to do
so can result in damage to equipment and/or serious injury to personnel.
To help ensure a safe operating environment, you should take advantage of the safety features
listed below. These features must not be construed as the only methods of ensuring safety.
See Also refers you to where you can find more in-depth information about the feature (system
connections and/or programming instructions)
Feature
Description
See Also
Enable Input
The ENABLE input, found on the product’s drive I/O connector, is
provided as an emergency stop input to the controller.
Product’s
hardware
Installation Guide
If the ENABLE input is opened (disconnected from GND), output to
the motors is inhibited.
End-of-travel
Limit Inputs
End-of-travel limits prevent the load from crashing through
mechanical stops, an incident that can damage equipment and injure
personnel. Use hardware or software limits, as your application
requires.
End-of-Travel
Limits
(page 74)
User Fault
Input
Using the INFNCi-F command or the LIMFNCi-F command, you
can assign the user fault function to any of the programmable inputs.
You can then wire the input to activate when an external event,
considered a fault by the user, occurs.
Input Functions
(page 99)
Maximum
Allowable
Position Error
(servos only)
A position error (TPER) is defined as the difference between the
commanded position (TPC) and the actual position as measured by
the feedback device (TFB). The maximum allowable position error is
set with the SMPER command. When the maximum allowable position
error is exceeded (usually due to instability or loss of position
feedback), the controller shuts down the drive and sets error status bit
#12 (reported by the TER command).
Servo Setup
(page 85)
If SMPER is set to zero (SMPERØ), position error will not be monitored.
☞
Programmed ErrorHandling Responses
When any of the safety features listed above are exercised (e.g., DFT input is activated, etc.),
the controller considers it an error condition. With the exception of the shutdown output
activation, you can enable the ERROR command to check for the error condition, and when it
occurs to branch to an assigned ERRORP program. Refer to Error Handling (page 30) for
further information.
Options Overview
Stand-Alone Interface Options
After defining and storing controller programs, the controller can operate in a stand-alone
fashion. A program stored in the controller may interactively prompt the user for input as part
of the program (input via I/O switches, thumbwheels, RP240, joystick). A joystick can be use
for situations requiring manual manipulation of the load.
Option
116
Gem6K Series Programmer’s Guide
Application Example
www.comoso.com
RP240
(see page 123)
Joystick
(see page 130)
Grinding: Program the RP240 function keys to select certain part types,
and program one function key as a GO button. Select the part you want
to grind, then put the part in the grinding machine and press the GO
function key. The controller will then move the machine according to the
predefined program assigned to the function key selected.
X-Y scanning/calibration: Enter the joystick mode and use the 2-axis
joystick to position an X-Y table under a microscope to arbitrarily scan
different parts of the work piece (e.g., semi-conductor wafer). You can
record certain locations to be used later in a motion process (e.g., for
drilling, cutting, or photographing the work piece). Refer to page 112 an
example using the joystick to teach positions.
ANI Analog Inputs
Injection Molding: Use for feedback from a pressure sensor to maintain
constant, programmable force. (Note: ANI control requires that you install
(see page Error! Bookmark not
an analog input SIM on an expansion I/O brick.)
defined.)
Programmable inputs scanned
in PLC Scan Mode
(see page 120)
The PLC Scan feature allows you to create a pre-compiled program that
mimics PLC functionality by scanning through the I/O faster than in a
normal program run. Because the functions of PLC programs are precompiled, delays associated with command processing are eliminated
during profile execution, allowing more rapid sequencing of actions than
would be possible with programs which are not compiled. Command
processing is then free to monitor other activities.
Programmable Logic Controller
The controller's programmable I/O may be connected to most PLCs. After defining and
storing controller programs, the PLC typically executes programs, loads data, and manipulates
inputs to the controller. The PLC instructs the controller to perform the motion segment of a
total machine process.
EXAMPLE (X-Y point-to-point): A PLC controls several tools to stack and bore several
steel plates at once. The controller is programmed to move an X-Y table in a pre-programmed
sequence. The controller moves the load when the inputs are properly configured, signals the
PLC when the load is in position, and waits for the signal to continue to the next position.
Host Computer Interface
A computer may be used to control a motion or machine process. A PC can monitor
processes and orchestrate motion by sending motion commands to the controller or by
executing motion programs already stored in the controller. This control might come from a
BASIC or C program. A BASIC program example is provided on page 117.Custom
Graphical User Interfaces (GUIs)
Compumotor offers tools you can use to create your own custom graphical user interfaces
(GUIs). More detailed descriptions are provided on page 144.
•
•
ActiveX Control: A Gem6K product communication control for custom 32-bit
applications (e.g., developed with VisualBasic). Provided with Motion Planner.
PanelMaker: A VBScript-based operator interface tool. This is an add-on to Motion
Planner, sold separately.
Chapter 5. Custom Profiling
117
www.comoso.com
Programmable I/O Devices
Programmable I/O Functions
Programmable inputs and outputs are provided to allow the controller to detect and respond to
the state of switches, thumbwheels, electronic sensors, and outputs of other equipment such as
drives and PLCs. Listed below are the programmable functions that may be assigned to the
programmable I/O.
Programmable I/O offering differs by product. The total number of onboard inputs and
outputs (trigger inputs, limit inputs, digital outputs) depends on the product. The total number
of expansion inputs and outputs (analog inputs, digital inputs and digital outputs) depends on
your configuration of expansion I/O bricks. To ascertain your product’s I/O bit patterns, refer
to page 91.
NOTE
Refer to page 90 for instructions on establishing programmable input and output functions.
Instructions for connecting to I/O devices are provided in your product’s Installation Guide.
Input Functions
Input functions may be assigned to two basic groups of programmable inputs. LIMFNC assigns
functions to the limit inputs found on the “LIMITS/HOME” connector. INFNC assigns functions to
the trigger inputs (on the “TRIGGERS/OUTPUTS” connector) and to the digital inputs installed on
expansion I/O bricks. The syntax, LIMFNCi-c or INFNCi-c, requires a letter designator (“c”)
that corresponds to an input function; options for the input functions are listed in the table below.
Letter Designator
Virtual Inputs
can be established
to provide programmable input
functionality for data
or external events
that are not
ordinarily
represented by
inputs. See page 94
for details.
Function
A....................General-purpose input (default function for triggers & inputs on I/O bricks)
B....................BCD program select
C....................Kill
D....................Stop
E....................Pause/Continue
F....................User fault
G....................<RESERVED>
H....................Trigger Interrupt for position capture or registration (trigger inputs only). Special trigger
functions can be assigned with the TRGFN command (see page 166).
I....................Cause alarm event (requires Ethernet interface) in Communications Server
J....................Jog in the positive-counting direction
K....................Jog in the negative-counting direction
L....................Jog velocity select
M....................Joystick release
N....................Joystick axis select
O....................Joystick velocity select
P....................One-to-one program select
Q....................Program security
R....................End-of-travel limit for positive-counting direction *
S....................End-of-travel limit for negative-counting direction *
T....................Home limit *
* The limit inputs are factory-set to their respective end-of-travel or home limit function (see page 91).
Output Functions
Command
Function
OUTFNCi-A ............General-purpose output (default function)
OUTFNCi-B ............Moving/not moving
OUTFNCi-C ............Program in progress
OUTFNCi-D ............Hardware or software end-of-travel limit encountered
OUTFNCi-E ............Stall indicator — stepper axes only
OUTFNCi-F ............Fault indicator (indicates drive fault input or user fault input is active)
OUTFNCi-G ............Position error exceeds max. limit set with SMPER — servo axes only
OUTFNCi-H ............Output on position
* The “i” in the command syntax represents the number of the programmable input (e.g., OUTFNC3-H
assigns onboard output #3 as an “output on position” function).
118
Gem6K Series Programmer’s Guide
www.comoso.com
Thumbwheels
You can connect the controller's programmable I/O to a bank of thumbwheel switches to
allow operator selection of motion or machine control parameters.
The commands that allow for thumbwheel data entry are:
INSTW.................. Establish thumbwheel data inputs
OUTTW.................. Establish thumbwheel data outputs
TW ......................... Read thumbwheels or PLC inputs
INPLC.................. Establish PLC data inputs
OUTPLC................ Establish PLC data outputs
Thumbwheel Setup
The controller’s programming language allows direct input of BCD thumbwheel data via the
programmable inputs. Use the steps below to set up and read the thumbwheel interface. Refer
to the Gem6K Series Command Reference for descriptions of the commands used below.
Step 1
Wire your thumbwheels to the Gem6K. Refer to your product’s Installation Guide for I/O
specifications.
Step 2
Set up the inputs and outputs for operation with thumbwheels. The data valid input will be an
input which the operator holds active to let the controller read the thumbwheels. This input is
not necessary; however, it is often used when interfacing with PLCs.
OUTPLC1,1-4,0,12
INPLC1,1-8,9
INLVL000000000
Step 3
; Configure PLC output set 1:
;
onboard outputs 1-4 are strobe outputs,
;
no output enable bit,
;
12 ms strobe time per digit read.
; Configure PLC input set 1:
;
onboard inputs 1-8 are data inputs,
;
onboard input 9 is a sign input,
;
no data valid input.
; Onboard inputs 1-9 configured active low
The thumbwheels are read sequentially by outputs 1-4, which strobe two digits at a time. The
sign bit is optional. Set the thumbwheels to +12345678 and type in the following commands:
VAR1=TW5
VAR1
;
;
;
;
Assign data from all 8 thumbwheel digits to VAR1
Displays the variable (*VAR1=+0.12345678).
If you do not receive this response, return to
step 1 and retry.
PLCs
The controller’s programmable I/O may be connected to most PLCs. After defining and
storing controller programs, the PLC typically executes programs, loads data, and manipulates
inputs to the controller. The PLC instructs the controller to perform the motion segment of a
total machine process.
Refer to your product’s Installation Guide for instructions on connecting to I/O devices. For
higher current or voltages above 24VDC, use external signal conditioning such as OPTO-22
compatible I/O signal conditioning racks. Contact your local distributor or automation
technology center for information on these products.
Chapter 5. Custom Profiling
119
www.comoso.com
PLC Scan Mode
The PLC feature allows you to create a pre-compiled program that mimics PLC functionality by
scanning through the I/O faster than in a normal program run. Because the functions of PLC
programs are pre-compiled, delays associated with command processing are eliminated during
profile execution, allowing more rapid sequencing of actions than would be possible with
programs which are not compiled. Command processing is then free to monitor other activities.
Scan Time
To check how much time
(in 2 ms increments) the
last scan took to complete,
issue the TSCAN command
or use the SCAN operand
for variable assignments
and IF conditions.
For example, if the last
PLC program took 3
system updates (2 ms
each) to scan, then TSCAN
would report *TSCAN6,
indicating that it took 6 ms
to complete the scan.
Each pass, if taking the
same path through the
conditional branches (IF
statements), will always
report the same TSCAN
value.
To Implement a
PLC Program …
The PLC program is
scanned/ executed at
the beginning of the
2-ms update period.
The scan will stop after
30 segments have been
executed and resume at
the next 2-ms update.
PLCP programs, when
compiled, comprise a
linked list of PLC
segments. During a
scan, each segment is
counted until the total
number of segments
executed exceeds 30.
Time (msec)
To ascertain the scan time
required to execute 30
segments, use TSCAN
or [SCAN].
0
Begin Scan Window
Scanning
30-segment limit
•
•
•
•
I/O Updated by System
Trajectories calculated
Programs/Tasks run
Etc.
Begin New Scan
(or resume scan
at next segment)
2 millisecond
System Update Period
2 msec
Scanning
End Scan Window
Note: In Scan mode, when a
scan is complete, the next scan
will begin at the start of the
next 2 ms System Update Period.
If the 30-segment limit
occurs while executing
a multi-segment
statement, then that statement will finish no matter how many segments it executes. For
example, if 29 segments have executed, then the next segment will cause the scan to pause
until the next 2-ms update. If that next statement is VARI1=1PE, which executes 2 segments,
then VARI1=1PE will complete its operations before pausing the scan.
1. Define the PLC program (DEF PLCPi statement, followed by commands from the list
below, followed by END). Up to 99 PLC programs may be defined, identified as PLCP1,
PLCP2, PLCP3, and so on. Only these commands are allowed in a PLC program:
• IF, ELSE, and NIF (conditional branching) —The PLC program uses the non-scaled
integer (“raw”) operand values (e.g., PE value is not scaled by SCLD or ERES; PANI
value is ADC counts, not volts). The only operands that are not allowed are: SIN,
COS, TAN, ATAN, VCVT, SQRT, VAR, TW, READ, DREAD, DREADF, DAT, DPTR, and PI.
• L and LN (loops)
• HALT —
- If the PLC program is executed with SCANP, HALT will terminate the current
PLC program and kill the SCANP mode
- If the PLC program is executed with PRUN, HALT will stop the PLC program
(and the program that executed the PRUN statement) running in that task.
• BREAK —
- If the PLC program is executed with SCANP, BREAK will end only the current
scan loop. At the next 2-millsecond update, the scan will restart at the first line
of the PLC program.
- If the PLC program is executed with PRUN, BREAK will stop the PLC program
and execution will continue in the program from which the PRUN was executed
(resuming at the command immediately following the PRUN command).
• TIMST and TIMSTP (start and stop the timer) —
• OUT (turn on a digital output)
120
Gem6K Series Programmer’s Guide
www.comoso.com
• ANO (set an analog output voltage – requires an extended I/O brick with on an
analog output SIM) —
• EXE (execute a program in a specific task — e.g., 2%EXE MOVE)
• PEXE (execute a compiled program in a specific task — e.g., 3%PEXE PLCP4)
• VARI (integer variables). A VARI assignment expression is limited to one math
function — either addition (+) or subtraction (-). The operands can be any of the
monitored integer assignment operators (e.g., PE, PC, etc.).
NOTE: The PLC program uses the non-scaled (“raw”) operand values.
• VARB (binary variables). Bitwise operations are limited to Boolean And (&),
Boolean Inclusive Or (|), and Boolean Exclusive Or (^). The operands can be any
of the monitored binary assignment operators (e.g., IN, LIM, AS, VARB, etc.).
2. Compile the PLC program (PCOMP PLCPi). A compiled program runs much faster than a
standard program. After the PLCP program is compiled, it is placed in the Gem6K
controller’s “compiled” memory partition (see MEMORY command). To verify which PLC
programs are compiled, type in the TDIR command; compiled PLC programs are identified
as “COMPILED AS A PLC PROGRAM”.
3. Execute the PLC program (SCANP PLCPi). When the PLC program is launched with the
SCANP command, it is executed in the “PLC Scan Mode”. The advantage of the PLC Scan
Mode is that the PLC program is executed within a dedicated 0.5 ms time slot during every
2 ms system update period. This gives the PLCP program faster throughput for monitoring
and manipulating I/O.
An alternative execution method is to use the PRUN command (PRUN PLCPi). This method
is similar to the SCANP PLCPi method, but will only run through the PLCP program once.
Technical Notes
About PLC
Programs
• Controller Status bit #3 is set when a PLCP program is being executed in Scan Mode. To
check the controller status, use SC, TSC, or TSCF.
• Launching programs external to the scan: Using the EXE command or the PEXE
command, a scan program can launch another program in a specified task. EXE launches a
standard, non-compiled program; PEXE launches a compiled program.
• Stopping the scan: The scan program can be stopped in either of two ways: using the !K
command, or clearing the scan program by issuing a SCANP CLR command.
• Timing the PLC program outputs: It is not possible to control where the PLC program
will pause if the scan takes more than the allowed time. This means that there can be a
time lag of several update periods before the outputs, analog outputs, and/or variables
affected by the PLC program are updated. The order in which the scan takes place should
be considered when creating PLC programs to minimize the effects of such a lag. One
way to avoid the lag is to create a binary variable as a temporary holding place for the
desired output states. The last commands before the END statement of the PLC program
can set the outputs according to the final status of the variable, such that all output states
are written at the same time, just as the scan completes. This method is demonstrated in the
example program below.
• Memory Requirements: Most commands allowed in a PLC program consume one
segment of compiled memory after the program is compiled with PCOMP; the exceptions
are VARI and VARB (each consume 2 segments) and IF statements. Each IF conditional
evaluation compounded with either an AND or an OR operator consumes an additional
segment (e.g., IF(IN.1=b1 AND 1AS.1=b0) consumes three segments of compiled
memory). The number of compounds is limited only by the memory available.
• Order of Evaluation for Conditional Expressions:
Because only one level of parenthesis is allowed, the order of evaluation of IF
Chapter 5. Custom Profiling
121
www.comoso.com
conditionals is from left to right. Refer to the flowchart below for the evaluation logic.
Get Next Conditional
FALSE
NO
Compound = OR?
TRUE
Evaluate
YES
YES
Statement
Evaluates FALSE
Programming
Example
NO
Compound = AND?
Statement
Evaluates TRUE
DEF PLCP3
; Binary states of outputs 1-6 represented by VARB1 bits 1-6.
; Outputs 1-6 set at the end of program.
VARB1=b000000
; Initialize binary variable 1
IF(IN.1=b1)
; If onboard input 1 is ON, turn output 1
VARB1=VARB1 | b100000 ; Set binary bit for output 1 only to ON
NIF
IF(IN.2=b1)
; If onboard input 2 is ON, turn output 2
VARB1=VARB1 | b010000 ; Set binary bit for output 2 only to ON
NIF
IF(IN.3=b1)
; If onboard input 3 is ON, turn output 3
VARB1=VARB1 | b001000 ; Set binary bit for output 3 only to ON
NIF
IF(IN.4=b1)
; If onboard input 4 is ON, turn output 4
VARB1=VARB1 | b000100 ; Set binary bit for output 4 only to ON
NIF
IF(IN.5=b1)
; If onboard input 5 is ON, turn output 5
VARB1=VARB1 | b000010 ; Set binary bit for output 5 only to ON
NIF
IF(IN.6=b1)
; If onboard input 6 is ON, turn output 6
VARB1=VARB1 | b000001 ; Set binary bit for output 6 only to ON
NIF
OUT(VARB1)
; Turn on appropriate onboard outputs
END
ON
ON
ON
ON
ON
PCOMP PLCP3
; Compile program PLCP3
SCANP PLCP3
; Run compiled program PLCP3 in Scan mode. See diagram.
Time (msec)
DEF PLCP3
VARB1=b000000
IF(IN.1=b1)
VARB1=VARB1 |
NIF
IF(IN.2=b1)
VARB1=VARB1 |
NIF
IF(IN.3=b1)
VARB1=VARB1 |
NIF
IF(IN.4=b1)
VARB1=VARB1 |
NIF
IF(IN.5=b1)
VARB1=VARB1 |
NIF
IF(IN.6=b1)
VARB1=VARB1 |
NIF
OUT(VARB1)
END
0
Scanning
b100000
Pause Scan
b010000
2 msec
b001000
b000100
Scan
Scanning
Complete
b000010
4 msec
b000001
Scanning
Begin New
Scan
6 msec
Scanning
2 System Update Periods are needed to complete the scan
for compiled program PLCP3, for a total of 4 msec.
The response to a TSCAN command would be: *TSCAN4.
122
ON
Gem6K Series Programmer’s Guide
www.comoso.com
RP240 Remote Operator Panel
Gem6K Series products are directly compatible with the Compumotor RP240 Remote
Operator Panel. This section describes how to use your Gem6K product with the RP240.
Instructions for connecting the RP240 are provided in the Gem6K Hardware Installation
Guide. Refer to the Model RP240 User Guide (p/n 88-012156-01) for information on RP240
hardware specifications, mounting guidelines, environmental considerations, and
troubleshooting.
You may use the RP240's programmable
features to make it a custom operator
interface (see Operator Interface Features
below), or you may use the RP240's
default menu structure to run programs,
jog the load, enable/disable drive, check
status information, reset the Gem6K (see
Using the Default Menus below).
Compumotor
FIRST LINE ­ 40 CHARACTERS MAXIMUM
SECOND LINE ­ 40 CHARACTERS MAXIMUM
MENU
RECALL
MENU RECALL selects the
previous menu display.
POWER
F1
F2
F3
CONTRAST
INCREASE
LEDs. Turn on and off with
the DLED command.
CONTRAST
DECREASE
!
Same effect as sending a !S
command. Motion is stopped
(all axes) at the last specified AD
deceleration value. Effect on
program execution depends on
the COMEXS setting (see page
15 for details). Stop key may be
disabled with DSTP0.
2-line, 40-character display.
Use the DPCUR and DWRITE
commands to create your own
messages, or use the default
menus.
RP240
"
#
$
%
&
STOP
PAUSE
CONTINUE
Same effect as sending a !C command. If you previously pressed the PAUSE
button, this button continues program execution. If you previously pressed the
STOP button, motion is resumed (and program execution if the COMEXS1 mode
is in effect).
F4
F5
F6
1
2
3
4
5
6
7
8
9
0
.
+/­
C/E
ENTER
Use these keys to select menu
items. Each function key (and
MENU RECALL ) has a numeric
value that can be read into a
numeric variable (VAR) with
the DREADF command.
Use the numeric keypad to
enter values and then press
the ENTER button. Use the
DREAD command to read the
numeric value into numeric
variables (VAR) or to use as
variable assignment for a
command (e.g., D(DREAD)).
Jog Mode: Use the left & right
arrows ( & ) to jog axis #1
in the positive & negative
direction. Use the up & down
arrows ( & ) to jog axis #2.
Same effect as sending a !PS command ­ pauses program
execution until you press CONTINUE . Motion is not paused (use
the STOP button to stop motion).
Configuration
NOTE
As shipped from the factory, your Gem6K product is configured to operate an RP240 from the
RS-232 connector (referred to as the “COM 2” port). This should be appropriate for the
majority of applications requiring RP240 interface.
For more information
on controlling your
product's multiple
serial ports, refer to
page 56.
Every Gem6K Series product has two serial ports. The RS-232/485 connector is referenced as
the “COM1” serial port, and the RS-232 connector is referenced as the “COM2” serial port.
To configure the Gem6K product's serial ports for use with the RP240 and/or Gem6K language
commands, use the DRPCHK command. Be sure to select the affected serial port (COM 1 or
COM 2) with the PORT command before you execute the DRPCHK command. Once you issue
the DRPCHK command, it is automatically saved in non-volatile memory. The configuration
options are:
DRPCHKØ ..........Use the serial port for Gem6K commands only (default for COM 1)
DRPCHK1 ..........Check for RP240 on power up or reset. If detected, initialize RP240.
If no RP240, use serial port for Gem6K commands.
DRPCHK2 ..........Check for RP240 every 5-6 seconds. If detected, initialize RP240. Do not use
Chapter 5. Custom Profiling
123
www.comoso.com
port for Gem6K commands.
DRPCHK3 ..........Check for RP240 on power up or reset. If detected, initialize RP240.
If no RP240, use serial port for DWRITE command only. The DWRITE command
can be used to transmit text strings to remote RS-232C devices. (default setting
for COM 2)
Example
COM 2 is to be used for RS-232; COM 1 is to be used for RP240, but the RP240 will be plugged
in on an as-needed basis. The set-up commands for such an application should be executed in
the following order:
PORT1
DRPCHK2
PORT2
DRPCHKØ
;
;
;
;
Select COM1 serial
Configure COM1 for
Select COM2 serial
Configure COM2 for
port for setup
RP240, periodic check
port for setup
Gem6K commands only
Operator Interface Features
The RP240 may be used as your product’s operator interface, not a program entry terminal.
As an operator interface, the RP240 offers the following features:
• Displays text and variables
• 8 LEDs can be used as programmable status lights
• Operator data entry of variables: read data from RP240 into variables and command
value substitutions (see Command Value Substitutions on page 7).
Typically the user creates a program in the Gem6K controller to control the RP240 display
and RP240 LEDs. The program can read data and make variable assignments via the RP240's
keypad and function keys.
The Gem6K Series software commands for the RP240 are listed below. Detailed descriptions
are provided in the Gem6K Series Command Reference. The example below demonstrates the
majority of these Gem6K Series commands for the RP240.
DCLEAR............Clear The RP240 Display
DJOG................Enter RP240 Jog Mode
[DKEY]............Numeric value of RP240 Key
DLED................Turn RP240 LEDs On/Off
DPASS..............Change RP240 Password
DPCUR..............Position The Cursor On The RP240 Display
[DREAD] .........Read RP240 Data
[DREADF] .......Read RP240 Function Key
DREADI............RP240 Data Read Immediate Mode
DRPCHK............Check for RP240
DSTP................Enable/Disable the RP240 Stop Key
DVAR................Display Variable On RP240
DWRITE............Display Text On The RP240 Display
124
Gem6K Series Programmer’s Guide
www.comoso.com
Programming
Example
DEF panel1
REPEAT
DCLEAR0
DWRITE"SELECT A FUNCTION KEY"
DPCUR2,2
DWRITE"DIST"
DPCUR2,9
DWRITE"GO"
DPCUR2,35
DWRITE"EXIT"
VAR1 = DREADF
IF (VAR1=1)
GOSUB panel2
ELSE
IF (VAR1=2)
DLED1
GO1
DLED0
NIF
NIF
UNTIL (VAR1=6)
DCLEAR0
DWRITE"LAST FUNCTION KEY = F"
DVAR1,1,0,0
END
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
Define program panel1
Start of repeat loop
Clear display
Display text "SELECT A FUNCTION KEY"
Move cursor to line 2 column 2
Display text "DIST"
Move cursor to line 2 column 9
Display text "GO"
Move cursor to line 2 column 35
Display text "EXIT"
Input a function key
If function key #1 hit
GOSUB program panel2
Else
If function key #2 hit
Turn on LED #1
Start motion on axis #1
Turn off LED #1
End of IF (VAR1=2)
End of IF (VAR1=1)
Repeat until VAR1=6 (function key 6)
Clear display
Display text "LAST FUNCTION KEY = F"
Display variable 1
End of panel1
DEF panel2
DCLEAR0
DWRITE"ENTER DISTANCE"
D(DREAD)
END
;
;
;
;
;
Define prog panel2
Clear display
Display text "ENTER DISTANCE"
Enter distance number from RP240
End of panel2
Using the Default Menus
On power-up, the Gem6K product will automatically default to a mode in which it controls
the RP240 with the menu-driven functions listed below.
• Run a stored program (RUN, STOP, PAUSE and CONTINUE functions)
The flow chart below
illustrates the RP240's
menu structure in the
default operating mode
(when no Gem6K
product user program
is controlling the
RP240). Press the
Menu Recall key to
back up to the previous
screen. The menu
functions are described
in detail below.
• Jog the load
• Display the status of:
- System (TSS), for each task
- Axis (TAS)
- Extended Axis (TASX)
- I/O (TIN and TOUT)
- Limits (TLIM) and ENABLE input (TINO bit #6)
- Position: Commanded (TPC), Encoder (TPE)
- Firmware revision levels for the Gem6K product (TREV) and the RP240
• Enable or disable the internal drive (DRIVE)
• Access RP240 menu functions with a security password (set with DPASS)
• Reset the Gem6K product (equivalent to the RESET command)
NOTE: To disable these menus, the start-up program (the program assigned with the
STARTP command) must contain the DCLEARØ command.
Chapter 5. Custom Profiling
125
www.comoso.com
Default
Power-up
Menu
• If you change the password with the DPASS command, the menu marked with [ALT] becomes the power-up menu.
The default password is “6800” for the Gem6K controller.
• Arrows indicate the menu path when you press the corresponding function key below the menu item.
• To back up to the previous menu item, press the MENU RECALL button.
COMPUMOTOR GEM6K
RUN
JOG STATUS DRIVE
DISPLAY
ETC
PROGRAM TO RUN IS:
FIND ALPHA
TRACE
STEP
AXIS 1: L/R
LO Ø.5ØØØ
EDIT
JOG*
COMPUMOTOR GEM6K
GO-BACK REV RESET
ETC
COMPUMOTOR GEM6K
ACCESS RUN
[ALT]
ACCESS xxxx
Enter password then press ENTER
PROGRAM TO RUN IS:
FIND ALPHA
SYSTEM
STATUS
TRACE
STEP
AXIS
AXIS
STATUS XSTATUS
SYSTEM STATUS BIT SEL:L/R TASK SEL:U/D
ØTSS: 1ØØØ11ØØØØØØØØØØØØØØ11ØØØØØØØØØØ
GEM6K REV: 92-Ø1674Ø-Ø1-6.x
RP24Ø REV: 92-Ø12951-Ø1F
AXIS STATUS
BIT SEL:L/R
1TAS: ØØ1ØØØØØØØØØ1ØØØØØØØØØØ11ØØØØØØØ
AXIS XSTATUS
BIT SEL:L/R
1TASX: ØØØØØ1ØØØØØØØØØØØØØØØØØØØØØØØØØØ
CONFIRM RESET
YES
NO
DRIVE: OFF
ON
OFF
DISPLAY:
INPUT OUTPUTS LIMITS
POS
POSITION:
ENC
COM
ØIN:
ØØØØ_Ø
I/O BRICK SELECT: U/D
ØOUT:
ØØØØ_ØØØ
I/O BRICK SELECT: U/D
LIMITS:
AXIS 1: POS:1
ERROR
ENCODER:
AXIS 1: -1
COMMAND:
AXIS 1: -1
NEG:1
JOYSTICK:
CH1,2,3,4: 0.000
126
JOY
HOME:0
0.000
ENABLE:1
0.000
0.000
Gem6K Series Programmer’s Guide
POSITION ERROR:
AXIS 1: -1
GV6K only
www.comoso.com
Running a Stored
Program
COMPUMOTOR GEM6K
RUN
JOG STATUS DRIVE
DISPLAY
COMPUMOTOR GEM6K
ACCESS RUN
ETC
or
PROGRAM TO RUN IS:
FIND ALPHA
TRACE
PROGRAM TO RUN IS:
FIND ALPHA
STEP
TRACE
STEP
After accessing the RUN menu, press F1 to “find” the names of the programs stored in the
Gem6K product’s memory; pressing F1 repeatedly displays subsequent programs in the order
in which they were stored in BBRAM. To execute the program, press the ENTER key.
To type in a program name at the location of the cursor, first select alpha or numeric
characters with the F2 function key (characters will be alpha if an asterisk appears to the right
of ALPHA, or numeric if no asterisk appears). If alpha, press the up (2) or down (8) keys to
move through the alphabet, if numeric, press the desired number key. Press F3 to move the
cursor to the left, or F4 to move the cursor to the right.
Only user programs defined with DEF and END may be executed from this menu. Compiled
profiles (GOBUF profiles) cannot be executed from this menu; they must be executed from the
terminal emulator with the PRUN command, or you can place the PRUN (name of path)
command in a user program and then execute that program from this menu.
HINT: If you wish to
display each command as
it is executed, select STEP
and TRACE and press the
ENTER key to step
through the program.
Jogging
When a program is RUN and TRACE is selected (TRACE*), the RP240 display will trace all
program commands as they are executed. This is different from the TRACE command in that
the trace output goes to the RP240 display, not to a terminal via the serial port.
When a program is RUN and STEP is selected, step mode has been entered. This is similar to
the STEP command, but when selected from the RUN menu the step mode allows single
stepping by pressing the ENTER key. Both RP240 trace mode and step mode are exited when
program execution is terminated.
COMPUMOTOR GEM6K
RUN
JOG STATUS DRIVE
AXIS 1: L/R
LO Ø.5ØØØ
DISPLAY
EDIT
ETC
JOG*
You can jog the axis by pressing the arrow keys on the RP240’s numeric keypad. The left and
right arrow keys are for jogging the axis in the negative and positive direction, respectively.
Pressing an arrow key starts motion and releasing the arrow key stops motion.
The HI and LO values in the jog menu represent the velocity in units of revs/sec. If scaling is
enabled, the value is multiplied by the programmed SCLV value.
To edit the jog velocity* values:
1. Press the F5 function key under EDIT (edit mode indicated with an asterisk).
2. Press the F1 function key to select the HI and LO values (cursor appears under the
first digit of the value selected).
3. Using the numeric keyboard, enter the value desired.
4. Repeat steps 2 and 3 for all values to be changed.
5. Press ENTER when finished editing.
6. To jog with the new velocity values, first press the F6 function key (under JOG) to
enable the arrow keys again.
Jog accel and decel values are specified by the JOGA and JOGAD commands, respectively.
Chapter 5. Custom Profiling
127
www.comoso.com
Status Reports:
System & Axis
COMPUMOTOR GEM6K
RUN
JOG STATUS DRIVE
SYSTEM
STATUS
DISPLAY
ETC
AXIS
AXIS
STATUS XSTATUS
SYSTEM STATUS BIT SEL:L/R TASK SEL:U/D
ØTSS: 1ØØØ11ØØØØØØØØØØØØØØ11ØØØØØØØØØØ
AXIS STATUS
BIT SEL:L/R
1TAS: ØØ1ØØØØØØØØØ1ØØØØØØØØØØ11ØØØØØØØ
AXIS XSTATUS
BIT SEL:L/R
1TASX: ØØØØØ1ØØØØØØØØØØØØØØØØØØØØØØØØØØ
After accessing the desired status menu, you can ascertain the function and status of each
system (TSS, for each task) or axis (TAS and TASX) status bit by pressing the arrow keys on
the numeric keypad.
To view a more descriptive explanation of each status bit (includes a text description), press
the left or right arrow keys on the numeric keypad.
Status Reports:
I/O, Limits, Position
COMPUMOTOR GEM6K
RUN
JOG STATUS DRIVE
DISPLAY:
INPUT OUTPUTS LIMITS
DISPLAY
JOY
ETC
POS
POSITION:
ENC
COM
ØIN:
ØØØØ_Ø
I/O BRICK SELECT: U/D
ØOUT:
ØØØØ_ØØØ
I/O BRICK SELECT: U/D
LIMITS:
AXIS 1: POS:1
ERROR
ENCODER:
AXIS 1: -1
COMMAND:
AXIS 1: -1
NEG:1
JOYSTICK:
CH1,2,3,4: 0.000
HOME:0
0.000
ENABLE:1
0.000
0.000
POSITION ERROR:
AXIS 1: -1
GV6K only
INPUTS Menu: This menu displays the TIN bit patterns for programmable inputs (onboard
triggers and digital inputs on expansion I/O bricks). Remember that I/O bit patterns vary by
product (see page 91 to find the bit patterns for your product). The initial menu show the
trigger inputs status; use the up and down arrows to select the status of inputs on expansion
I/O bricks.
OUTPUTS Menu: This menu displays the TOUT bit patterns for programmable outputs
(onboard outputs and digital outputs on expansion I/O bricks). Remember that I/O bit patterns
vary by product (see page 91 to find the bit patterns for your product). The initial menu show
the onboard outputs; use the up and down arrows to select the status of outputs on expansion
I/O bricks.
128
Gem6K Series Programmer’s Guide
www.comoso.com
LIMITS Menu:
• The POS, NEG and HOME status items represent the hardware states of the limit inputs
on the “LIMITS/HOME” connector, regardless of their LIMFNC input function
assignments; they do not represent INFNC limit functions assigned to onboard trigger
inputs or digital inputs on expansion I/O bricks.
• “POS” refers to the hardware end-of-travel limit imposed when counting in the positive
direction. “NEG” refers to the limit imposed when counting in the negative direction.
• A “1” indicates that the input is grounded, “0” indicates not grounded.
The end-of-travel limits (POS and NEG) must be grounded to allow motion (this is
reversed if the active level is reversed with the LIMLVL command).
The Enable input (ENABLE input terminal) must also be grounded before motion is
allowed. When not grounded, the output to the motor is cut off and the shutdown
outputs are activated.
POS Menu:
• The position values (encoder, commanded, and position error) shown are continually
updated.
• The position error (“ERROR”) report is applicable only to servo axes.
• Position values are subject to the SCLD scaling factor (if scaling is enabled—SCALE1),
PSET offset value, encoder polarity (ENCPOL), and commanded direction polarity
(CMDDIR).
Enabling and
Disabling the Drive(s)
COMPUMOTOR GEM6K
RUN
JOG STATUS DRIVE
DRIVE
ON
DISPLAY
ETC
1: OFF
OFF
In the DRIVE menu, the current status of the drive(s) is displayed. To enable or disable the
drive, press F1 or F2, respectively This menu offers the same functionality as the DRIVE
command.
WARNING
Shutting down a rotary drive system allows the load to freewheel if there is no brake installed.
Access Security
COMPUMOTOR GEM6K
RUN
JOG STATUS DRIVE
DISPLAY
COMPUMOTOR GEM6K
GO-BACK REV RESET
ETC
ETC
COMPUMOTOR GEM6K
ACCESS RUN
Default menu after changing DPASS
ACCESS xxxx
Enter password then press ENTER
Access
Approved
Access
Denied
If the RP240 password is modified with the DPASS command to be other than the default (see
Changing the Password below) the ACCESS menu then becomes the new default menu after
power-up or executing a RESET. After that, the new password must then be entered to access
the original default menu (see “Access Approved” path in illustration). If the operator does not
know the new password, all he or she can do is run programs stored in the Gem6K product
(RUN).
Chapter 5. Custom Profiling
129
www.comoso.com
Changing the Password: The default password for Gem6K products is “6000”. A new
password (numeric value of up to 4 characters) can be established with the DPASS command.
For example, the DPASS2001 command sets the password to 2001.
Revision Levels
COMPUMOTOR GEM6K
RUN
JOG STATUS DRIVE
DISPLAY
COMPUMOTOR GEM6K
GO-BACK REV RESET
ETC
ETC
GEM6K REV: 92-Ø1674Ø-Ø1-6.x
RP24Ø REV: 92-Ø12951-Ø1F
Resetting the Gem6K
Product
COMPUMOTOR GEM6K
RUN
JOG STATUS DRIVE
COMPUMOTOR GEM6K
GO-BACK REV RESET
DISPLAY
ETC
ETC
CONFIRM RESET
YES
NO
After accessing the RESET menu, press the F1 key to execute a reset (or press F2 to cancel
and exit the menu). The reset is identical to issuing a RESET command or cycling power to
the Gem6K product. If a start-up program has been assigned with the STARTP command,
that program will be executed.
CAUTION
Executing a reset will restore most command values (exclusions: see page 65) to their
factory default setting.
Joystick Control, Analog Inputs
☞
Refer to your
Installation Guide for
connection
procedures.
The Gem6K allows you to add analog input (ANI) SIMs to the expansion I/O bricks (sold
separately). Each ANI SIM provides 8 analog inputs. The default voltage range for these input
is -10VDC to +10VDC, but other ranges are selectable with the ANIRNG command. ANI
inputs may be used in a variety of ways:
• Control an axis with a joystick (see Joystick Control)
• Use the voltage value to control other events. The voltage value on the ANI inputs can
be read using the ANI or TANI commands.
Joystick Control
The controller supports joystick operation with digital inputs and analog inputs. The digital
inputs include the onboard limit inputs and trigger inputs, as well as digital input SIMs on an
external I/O brick. The 12-bit analog inputs are available on board (single analog input) or if
you install an analog input SIM on an external I/O brick (default voltage range is -10V to
+10V, selectable with ANIRNG).
130
Gem6K Series Programmer’s Guide
www.comoso.com
To Set Up Joystick
Operation
(refer also to the
example code below)
1. Select the required digital inputs and analog inputs required for joystick operation. Connect
the joystick as instructed in your controller’s Installation Guide.
2. Assign the appropriate input functions to the digital inputs used for joystick's operation:
• Release Input: INFNCi-M for triggers & I/O brick inputs, or LIMFNCi-M for limit
inputs.
• Velocity Select Input: INFNCi-O for triggers & external inputs, or LIMFNCi-O for
limit inputs.
3. (optional) Use the ANIRNG command to select the voltage range for the analog inputs you
will use. The default range is -10VDC to +10VDC (other options are 0 to +5V, -5 to +5V,
and 0 to +10V).
4. Use the JOYAXH command to assign the analog input that will control the axis.
5. Define the joystick motion parameters:
• Max. Velocity when Velocity Select input switch is open/high (JOYVH command). If
the Velocity Select input is not used, joystick motion always uses the JOYVH velocity.
• Max. Velocity when Velocity Select input switch is closed/low (JOYVL command).
• Accel (JOYA command).
• Accel for s-curve profiling (JOYAA command).
• Decel (JOYAD command).
• Decel for s-curve profiling (JOYADA command).
6. Define the usable voltage zone for your joystick:
(make sure you have first assigned the analog inputs – see step 3 above)
• End Deadband (JOYEDB): Defines the voltage offset (from the -10V & +10V
endpoints) at which max. velocity occurs. Default is 0.1V, maxing voltage at -9.9V and
+9.9V.
• Center Voltage (JOYCTR or JOYZ): Defines the voltage when the joystick is at rest to be
the zero-velocity center. Default JOYCTR setting is 0V.
• Center Deadband (JOYCDB): Defines the zero-velocity range on either side of the
Center Voltage. Default is 0.1V, setting the zero-velocity range at -0.1V to +0.1V.
7. To jog the axis:
a. In your program, enable Joystick Operation with the JOY command (Joystick Release
input must be closed in order to enable joystick mode). When the JOY command
enables joystick mode, program execution stops (assuming the Continuous Command
Execution Mode is disabled with the COMEXCØ command).
b. Move the load with the joystick.
c. When you are finished, open the Joystick Release input to disable joystick mode. This
allows program execution to resume with the next statement after the initial JOY
command that started the joystick mode.
Joystick
Programming
Example
(refer also to the
illustration below)
Application Requirements: This example represents a typical two-axis joystick application in
which a high-velocity range is required to move to a region, then a low-velocity range is
required for a fine search. After the search is completed it is necessary to record the load
positions, then move to the next region. A digital input can be used to indicate that the position
should be read. The Joystick Release input is used to exit the joystick mode and continue with
the motion program.
Hardware Configuration:
• An analog input SIM is installed in the 3rd slot of I/O brick 1. The eight analog inputs
(1-8) are addressed as input numbers 17-24 on the I/O brick. Analog input 17 will
control the motion.
• A digital input SIM is installed in the 1st slot of I/O brick 1. The eight digital inputs (18) are addressed as input numbers 1-8 on the I/O brick. Digital input 6 will be used for
the Joystick Release function, and input 7 will be used for the Joystick Velocity Select
input. Input 8 will be used to indicate that the position should be read.
Chapter 5. Custom Profiling
131
www.comoso.com
Setup Code (the drawing below shows the usable voltage configuration):
1INFNC7-M
1INFNC8-O
JOYAXH1-17
JOYVH1
; Assign Joystick Release f(n) to brick 1, input 7
; Assign Joystick Velocity Select f(n) to brick 1, input 8
; Assign analog input 17 to control the motion,
; Max. velocity is 10 units/sec when the
; Velocity Select input (1IN.7) is open (high)
JOYVL10
; Max. velocity is 1 unit/sec when the
; Velocity Select input (1IN.7) is closed (low)
JOYA100
; Set joystick accel to 100 units/sec/sec
JOYAD100
; Set joystick decel to 100 units/sec/sec
;**** COMMANDS TO SET UP USABLE VOLTAGE: **********
1JOYCTR.17=+1.0
; Set center voltage for analog input 17
; to+1.0V. The +1.0V value was
; ascertained by checking the voltage of the both
; inputs (with the 1TANI.17)
; when the joystick was at rest.
1JOYCDB.17=0.5
; Set center deadband to compensate for the fact that
; when the joystick is at rest, the voltage received on
; the analog input may fluctuate +/- 0.5V on either
; side of the +1.0V center.
1JOYEDB.17=2.0
; Set end deadband to compensate for the fact that the
; joystick can produce only -8.0V to +8.0V.
;**************************************************
JOY1
; Enable joystick mode
Velocity
(positive direction)
JOYVH or JOYVL
JOYEDB
JOYCDB
(zero-velocity range)
Volts
-10V
+10V
or JOYZ
(voltage when joystick is at rest)
JOYCTR
JOYEDB
JOYVH or JOYVL
Velocity
(negative direction)
Analog Input Interface
Refer to your product's
Installation Guide for
ANI connection
information.
132
Using analog (ANI) inputs on expansion I/O bricks, your controller can use analog voltage as a
means to control the program based on external conditions.
Each ANI SIM on an expansion I/O brick provides eight analog inputs. The 12-bit analog
inputs have a default voltage range of -10VDC to +10VDC. Other ranges are selectable with
the ANIRNG command (0 to +5VDC, 0 to +10VDC, and -5 to +5VDC). The voltage value of
the ANI inputs can be transferred to the terminal with the TANI command, or used in an
assignment or comparison operation with the ANI operator (e.g., IF(1ANI<2.4)).
Gem6K Series Programmer’s Guide
www.comoso.com
Host Computer Interface
Another choice for product control is to use a host computer and execute a motion program using
the serial interface (RS-232 or RS-485). A host computer may be used to run a motion program
interactively from a BASIC or C program (high-level program controls the Gem6K product and acts
as a user interface). A BASIC program example is provided below.
10
12
14
16
18
20
22
24
26
28
30
100
110
120
130
140
150
160
170
180
190
200
210
220
230
240
250
260
270
280
290
300
310
320
330
340
400
410
420
430
500
510
520
530
540
550
560
570
580
590
600
610
620
630
640
650
'
Gem6K Series Serial Communication BASIC Routine
'
Gem6K.BAS
'
' **************************************************************
'
' This program will set the communications parameters for the
' serial port on a PC to communicate with a Gem6K series
' stand-alone product.
'
' **************************************************************
'
'*** open com port 1 at 9600 baud, no parity, 8 data bits, 1 stop bit
'*** activate Request to Send (RS), suppress Clear to Send (CS), suppress
'*** DATA set ready (DS), and suppress Carrier Detect (CD) ***
OPEN "COM1:9600,N,8,1,RS,CS,DS,CD" FOR RANDOM AS #1
'
'*** initialize variables ***
MOVE$ = ""
' *** commands to be sent to the product ***
RESPONSE$ = ""
' *** response from the product ***
POSITION$ = ""
' *** feedback position reported ***
SETUP$ = ""
' *** setup commands ***
'
'*** format the screen and wait for the user to start the program ***
CLS : LOCATE 12, 20
PRINT "Press any key to start the program"
'
'*** wait for the user to press a key ***
PRESS$ = INKEY$
IF PRESS$ = "" THEN 260
CLS
'
'*** set a pre-defined move to make ***
SETUP$ = "ECHO1:ERRLVL0:LH0:"
MOVE$ = "A100:V2:D50000:GO1:TFB:"
'
'
'*** send the commands to the product ***
PRINT #1, SETUP$
PRINT #1, MOVE$
'
'
*** read the response from the TFB command ***
'
*** the controller will send a leading "+" or "-" in response to the TFB command to
'
*** indicate which direction travel has occurred. ***
WHILE (RESPONSE$ <> "+" AND RESPONSE$ <> "-") ' *** this loop waits for the "+"
RESPONSE$ = INPUT$(1, #1)
' *** or "-" characters to be returned
WEND
' *** before reading the position ***
'
WHILE (RESPONSE$ <> CHR$(13))
' *** this loop reads one character at a time
POSITION$ = POSITION$ + RESPONSE$ ' *** from the serial buffer until a carriage
RESPONSE$ = INPUT$(1, #1)
' *** return is encountered ***
WEND
'
'*** print the response to the screen ***
LOCATE 12, 20: PRINT "Position is " + POSITION$
'
'END
Chapter 5. Custom Profiling
133
www.comoso.com
Graphical User Interface (GUI) Development Tools
TO ORDER
To order Motion OCX Toolkit™, DDE6000™, or Motion Toolbox®, contact your local
Automation Technology Center (ATC) or distributor.
ActiveX Control
Provided with Motion Planner is the Gem6K ActiveX control, a 32-bit control which can be
used as an interface tool between your custom Windows application and the Gem6K product.
For example, you might use the ActiveX control with a third-part factory automation software
and operator interface, such as Wonderware's In-Touch™.
PanelMaker
Sold separately as an add-on utility to Motion Planner, PanelMaker is a custom GUI creation
tool based on the VisualBasic Scripting language. Using PanelMaker, you can create custom
interfaces for operator input and diagnostics. The PanelMaker custom controls include:
• Communication between the application and the Gem6K product•
134
Gem6K Series Programmer’s Guide
www.comoso.com
Custom Profiling
5
CHAPTER FIVE
Custom
Profiling
IN THIS CHAPTER
This chapter explains how to use these custom profiling features:
•
•
•
•
•
S-Curve Profiling ..............................................136
Compiled Motion Profiling ...............................139
On-the-Fly Motion (pre-emptive GOs) ..............155
Registration .......................................................159
Synchronizing Motion.......................................163
For basic motion (accel/velocity/distance), see page ....71
For homing profiles, see page ......................................79
For Following profiles, see page ...................................168
www.comoso.com
S-Curve Profiling
Controllers allow you to perform S-curve move profiles, in addition to the usual trapezoidal
profiles. S-curve profiling provides smoother motion control by reducing the jerk (rate of
change) in acceleration and deceleration portions of the move profile (see drawing below).
Because S-curve profiling reduces jerk, it improves position tracking performance.
Velocity
S-Curve
Time
Decel Accel
Decel Accel
Velocity
Trapezoidal
Time
Maximum Jerk
Time
Time
Less Jerk
S-Curve Programming Requirements
To program an S-curve profile, you must use the average accel/decel commands provided in
the Gem6K Series programming language. For every maximum accel/decel command (e.g.,
A, AD, HOMA, HOMAD, JOGA, JOGAD, etc.) there is an average command for S-curve
profiling (see table below).
Maximum Accel/Decel Commands:
Command
Function
Average (“S-Curve”) Accel/Decel Commands:
Command
Function
A
Acceleration
AA
Average Acceleration
AD
Deceleration
ADA
Average Deceleration
HOMA
Home Acceleration
HOMAA
Average Home Acceleration
HOMAD
Home Deceleration
HOMADA
Average Home Deceleration
JOGA
Jog Acceleration
JOGAA
Average Jog Acceleration
JOGAD
Jog Deceleration
JOGADA
Average Jog Deceleration
JOYA
Joystick Acceleration
JOYAA
Average Joystick Acceleration
JOYAD
Joystick Deceleration
JOYADA
Average Joystick Deceleration
LHAD
Hard Limit Deceleration
LHADA
Average Hard Limit Deceleration
LSAD
Soft Limit Deceleration
LSADA
Average Soft Limit Deceleration
PA
Path Acceleration
PAA
Average Path Acceleration
PAD
Path Deceleration
PADA
Average Path Deceleration
Determining the S-Curve Characteristics
The command values for average accel/decel (AA, ADA, etc.) and maximum accel/decel (A, AD,
etc.) determine the characteristics of the S-curve. To smooth the accel/decel ramps, you must
enter average accel/decel command values that satisfy the equation ½ A ≤ AA < A, where
A represents maximum accel/decel and AA represents average accel/decel. Given this
requirement, the following conditions are possible:
136
Gem6K Series Programmer’s Guide
www.comoso.com
Acceleration Setting
Profiling Condition
AA > ½ A, but AA < A............. S-curve profile with a variable period of constant acceleration. Increasing
the AA value above the pure S-curve level (AA > ½ A), the time required to
reach the target velocity and the target distance is decreased. However,
increasing AA also increases jerk.
AA = ½ A ................................ Pure S-curve (no period of constant acceleration—smoothest motion).
AA = A .................................... Trapezoidal profile (but can be changed to an S-curve by specifying a new
AA value less than A).
AA < ½ A; or AA > A............... When you issue the GO command, the move will not be executed and an
error message, *INVALID CONDITIONS FOR S_CURVE ACCELERATION—
FIELD n, will be displayed.
AA = zero................................ S-curve profiling is disabled. Trapezoidal profiling is enabled. AA tracks A.
(Track means the command's value will match the other command's value
and will continue to match whatever the other command's value is set to.)
However, if you enter an average decel command (e.g., ADA, HOMADA, etc.)
equal to zero, you will receive the “INVALID DATA-FIELD n” error.
AA ≠ zero and AA ≠ A ............ S-curve profiling is enabled only for standard moves (e.g., not for
compiled motion, or on-the-fly motion changes). All subsequent standard
moves for that axis must comply with this equation:
½ A ≤ AA < A.
AA > ½ A ................................ Average accel/decel is raised above the pure S-curve level; this decreases
the time required to reach the target velocity and distance. However,
increasing AA also increases jerk. After increasing AA, you can reduce jerk
by increasing A, but be aware that increasing A requires a greater torque to
achieve the commanded velocity at the mid-point of the acceleration profile.
No AA value ever entered ...... Profile will default to trapezoidal. AA tracks A.
If you never change the A or AA deceleration commands, AA deceleration will track AA
acceleration. However, once you change A deceleration, AA deceleration will no longer track
changes in AA acceleration. For example, if you never change the AD or ADA command values,
ADA will track the AA command value. But once you change AD, the ADA command value will
no longer track the changes in the AA command value.
The calculation for determining S-curve average accel and decel move times is as follows
(calculation method identical for S-curve and trapezoidal moves):
Time =
Velocity
or
A avg
Time =
2 ∗ Distance
A avg
Scaling affects the AA average acceleration (AA, ADA, etc.) the same as it does for the A
maximum acceleration (A, AD, etc.). See page 67 for details on scaling.
NOTE: Equations for calculating jerk are provided on page 138.
Programming Example
; In this example, axis 1 executes a pure S-curve and takes 1 second
; to reach a velocity of 5 rps.
SCALE0
; Disable scaling
DEF SCURV ; Begin definition of program SCURV
V
MA0
; Select incremental positioning mode
D40000
; Set distances to 40,000 positive; direction steps
A10
; Set max. accel to 10 rev/sec/sec
AA5
; Set avg. accel to 5 rev/sec/sec on
0
1
2
AD10
; Set max. decel to 10 rev/sec/sec
Move
profile
ADA5
; Set avg. decel to 5 rev/sec/sec on
V5
; Set velocity to 5 rps
GO1
; Execute motion
END
; End definition of program
Chapter 6. Following
T
3
137
www.comoso.com
Calculating Jerk
Rules of Motion:
Jerk =
A
(Programmed Accel)
Zero Acceleration
V
a=
dv
v=
dx
da
dt
dt
dt
(x = distance)
Assuming the accel profile starts
when the load is at zero velocity and
the ramp to the programmed velocity
is not compromised:
(Programmed Velocity)
V2
2
Jerk = JA =
V1
Zero Velocity
t2
= programmed acceleration
(A, AD, HOMAD, etc.)
AA = average acceleration
(AA, ADA, HOMAA, etc.)
V = programmed velocity
(V, HOMV, etc.)
t3
(zero)
A
B
A
C
A
t1 ≥ t ≥ Ø
-
AA
JA * t
v (t) =
A
JA * t
d (t) =
2
3
6
AA
B
NOTE: t3 - t2 = t1
t2 ≥ t > t1
a (t) = A
A
v (t) =
2
V1 =
a (t) = acceleration at time t
v (t) = velocity at time t
d (t) = distance at time t
2
JA
V
t3 =
a (t) = JA * t
JA
V
t2 =
V (A-AA)
A
t1
Ø
t1 =
A * AA
2
JA * t1
A
=
2
d (t) =
2
2JA
+ A * (t - t1)
J A * t1
3
6
2 * JA
+
A * (t - t1)
2
2
+ V1 * (t - t1)
2
A
V2 = V -
C
t3 ≥ t > t2
a (t) = A - (JA * (t - t2))
2 * JA
v (t) = V -
V
d (t) =
JA * (t3 - t)
2
2
2AA
2
+
JA (t3 - t)
6
3
- V * (t3 - t)
Starting at a Non-Zero Velocity: If starting the acceleration profile with a non-zero initial velocity, the move comprises
two components: a constant velocity component, and an s-curve component. Typically, the change of velocity should be
used in the S-curve calculations. Thus, in the calculations above, you would substitute “(VF - VO)” for “V” (VF = final
velocity, VO = initial velocity). For example, the jerk equation would be:
2
Jerk = JA =
138
Gem6K Series Programmer’s Guide
A * AA
(VF - VO) (A-AA)
www.comoso.com
Compiled Motion Profiling
Gem6K Series products allow you to construct complex individual axis motion profiles which
are compiled and saved. You can define separate and independent profiles for each individual
axis. The profiles may contain:
•
•
•
•
•
•
☞
PLCP programs are
stored in compiled
memory
(see page 11).
Sequences of motion
Loops
Programmable output changes
Embedded dwells
Direction changes
Trigger functions
Related Commands:
Brief descriptions of related
commands are found on page 139.
For detailed descriptions, refer to the
Gem6K Series Command Reference.
Compiled motion profiles are defined like programs (using the DEF and END commands); the
commands used to construct the motion profile segments are stored in a program (stored in
Program memory). This program is then compiled (using the PCOMP command) and the
compiled profile segments (GOBUF, PLOOP, GOWHEN, TRGFN, and POUTA statements) from
the program are stored in Compiled memory. (TIP: The TDIR command reports which
programs are compiled as a compiled profile.) You can then execute the compiled profile with
the PRUN command.
The amount of RAM allocated for storing compiled profile segments is determined by the
MEMORY command setting. The list below identifies memory allocation defaults and limits for
Gem6K Series products. Further details on re-allocating memory are provided on page 11.
Total memory (bytes) .........................................300,000
Default allocation (program,compiled)...............MEMORY150000,150000
Maximum allocation for compiled profiles ........MEMORY1000,299000
Maximum # of compiled profiles .......................300
Maximum # of compiled profile segments .........2069
CAUTIONS
• Issuing a memory allocation command (e.g., MEMORY70000,230000) will erase all existing
programs and compiled path segments. However, issuing the MEMORY command by itself (i.e.,
MEMORY—to request the status of how the memory is allocated) will not affect existing programs
or segments.
• After compiling (PCOMP) and running (PRUN) a compiled profile. The profile segments will be
deleted from compiled memory if you cycle power or issue a RESET command.
After compiling (PCOMP), you can execute the profiles with the PRUN command, and all of
the motion and functions compiled into the profile are executed without any further
commands during profile execution.
Because the motion and functions are pre-compiled, delays associated with command
processing are eliminated during profile execution, allowing more rapid sequencing of actions
than would be possible with programs which are not compiled. Command processing is then
free to monitor other activities, such as I/O and communications.
Chapter 6. Following
139
www.comoso.com
NOTES
• During compilation (PCOMP), most commands are executed the same as if no profile were being
defined, even those which are not relevant to the construction of a profile. This is also true of
non-compiled motion commands embedded in a compiled motion program during PCOMP. For
this reason, it’s good to limit commands between DEF and END to those which actually assist in
the construction of the profile. Even for those that do actually assist in the construction of the
profile, such as A, V, and D, it is important to remember that the command is executed and data
actually changes, and it is not restored after compilation is completed.
• If your compiled motion program contains variables, the variables are evaluation only at compile
time.
Each motion segment in a compiled motion profile may have its own distance, velocity,
acceleration, and deceleration, as shown in the program example below:
Programming
Example
DEF simple
MC0
D50000
A10
AD10
V5
GOBUF1
END
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
PCOMP simple
PRUN simple
; Compile simple
; Run simple
D30000
V2
GOBUF1
D40000
V4
GOBUF1
Begin definition of program simple
Preset positioning mode (disable continuous mode)
Distance is 50000
Acceleration is 10
Deceleration is 10
Velocity is 5
Store the first motion segment for axis 1.
Profile attributes are: MC0, A10, AD10, V5, D50000
Distance is 30000
Velocity is 2
Store the second motion segment for axis 1
Profile attributes are: MC0, A10, AD10, V2, D30000
Distance is 40000
Velocity is 4
Store the third motion segment for axis 1
Profile attributes are: MC0, A10, AD10, V4, D40000
Because this is the last segment in a preset profile,
the velocity will automatically end at zero.
End program definition
The resulting profile from the above program:
v
D50000
5
4
3
2
D30000
1
D40000
0
STATUS COMMANDS:
Use these commands to
check the status of
compiled profiles.
140
t
System Status (TSSF, TSS, & SS):
• Bit #29 is set if compiled memory is 75% full.
• Bit #30 is set if compiled memory is 100% full.
• Bit #31 is set if a compile (PCOMP) failed; this bit is cleared on power-up, reset, or after
a successful compile. Possible causes include:
- Errors in profile design (e.g., change direction while at non-zero velocity, distance
& velocity equate to <1 count/system update, preset move profile ends in non-zero
velocity).
- Profile will cause a Following error (see TFS, TFSF & FS status).
- Out of memory (see system status bit #30)
- Axis already in motion at the time of the PCOMP command
- Loop programming errors (e.g., no matching PLOOP or PLN, more than 4
embedded PLOOP/END loops)
Gem6K Series Programmer’s Guide
www.comoso.com
Axis Status (TASF, TAS, & AS): Bit #31 is set while compiled a GOBUF profile is executing.
TSEG & SEG: Reports the number of available segments in compiled memory.
TDIR: Identifies programs that are “compiled as a path” (compiled with the PCOMP
command) and reports the percentage of remaining compiled memory.
Rules for Using
Velocity in Preset
Compiled Motion
When defining preset mode (MC0) compiled profiles there are several rules that govern the
velocity.
Rule #1: The last segment in the compiled profile will automatically end at zero velocity (only
if not in a PLOOP/PLN loop).
DEF PROF5
MC0
V1
D4000
GOBUF1
V2
GOBUF1
END
PCOMP
; When you
V
; Begin definition of profile #5
; Select preset positioning
; Set velocity to 1 rev/sec
; Set distance to 4000
; First motion segment (V1, D4000)
; Set velocity to 2 (second segment)
; Second motion segment (V2, D4000)
; End definition of profile #5
; Compile profile #5
execute PRUN PROF5, the resulting profile is:
2
1
0
4000
8000
D
Rule #2: If you wish intermediate segments to end in zero velocity, use the VF0 command in
the respective GOBUF segment.
DEF PROF6
MC0
V1
VF0
D4000
GOBUF1
V2
VF0
GOBUF1
END
PCOMP
; When you
V
; Begin definition of profile #6
; Select preset positioning
; Set velocity to 1 rev/sec
; End this segment at zero velocity
; Set distance to 4000
; First motion segment (V1, D4000, VF0)
; Set velocity to 2 (second segment)
; End this segment at zero velocity
; Second motion segment (V2, D4000, VF0)
; End definition of profile #6
; Compile profile #6
execute PRUN PROF6, the resulting profile is:
2
1
0
4000
8000
D
Rule #3: CAUTION: With compiled loops (PLOOP and PLN), the last segment within the loop
must end at zero velocity or there must be a final segment placed outside the loop. Otherwise,
when the profile is compiled with PCOMP you’ll receive the “ERROR: MOTION ENDS IN
NON-ZERO VELOCITY–AXIS n” error message and system status bit #31 will be set. after the
final segment is completed, the motor will continue moving at the last segment’s velocity.
DEF PROF7
; Begin definition of profile #7
MC0
D3000
PLOOP4
V1
GOBUF1
PLN1
END
;
;
;
;
;
;
;
Select preset positioning
Set distance to 3000
Loop (between PLOOP & PLN) 4 times
Set velocity to 1 rev/sec
First motion segment
End loop
End definition of profile #7
Chapter 6. Following
141
www.comoso.com
PCOMP
; Compile profile #7, but instead of compile, you receive
; an error message
To fix the profile, reduce the PLOOP count by one and add a GOBUF statement after the PLN
command:
DEF PROF7
; Begin definition of profile #7
MC0
D3000
PLOOP3
V1
GOBUF1
PLN1
GOBUF1
END
PCOMP
; When you
V
; Select preset positioning
; Set distance to 3000
; Loop (between PLOOP & PLN) 3 times
; Set velocity to 1 rev/sec
; Looped motion segment
; End loop
; Last motion segment (end at zero velocity)
; End definition of profile #7
; Compile profile #7
execute PRUN PROF7, the resulting profile is:
2
1
0
3000
6000
9000
12000
D
Rule #4: With compiled loops (PLOOP and PLN), if you wish the velocity at the end of each
loop to end at zero, use a VF0 command.
DEF PROF8
; Begin definition of profile #8
MC0
; Select preset positioning
D3000
; Set distance to 3000
PLOOP4
; Loop (between PLOOP & PLN) 4 times
V1
; Set velocity to 1 rev/sec
VF0
; End each segment at zero velocity
GOBUF1
; Looped motion segment
PLN1
; End loop
END
; End definition of profile #8
PCOMP
; Compile profile #8
; When you execute PRUN PROF8, the resulting profile is:
V
2
1
0
3000
6000
9000
12000
D
Compiled Following Profiles
More details on
Following are
found in Chapter 6
(page 168).
The new FOLRNF command designates that the motor will move the load the distance
designated in a preset GOBUF segment, completing the move at the specified final ratio. The
only allowable value for FOLRNF is zero (0). FOLRNF is allowed for a segment only if the
starting ratio is also zero, i.e., it must be the first segment, or the previous segment must have
ended in zero ratio. FOLRNF is only useful with compiled preset Following moves because the
starting and final ratios are already zero for motion initiated with GO.
Compiled motion profiles may be constructed with any combination of preset or continuous
motion segments. A continuous (MC1) Following segment will start with the final ratio of the
previous segment, and end with the ratio given by FOLRN and FOLRD. The motion segment
will consist of one ramp from the starting ratio to the final ratio. Just as with continuous
Following ramps outside of a compiled profile, the master travel over which the ramp takes
place is specified with FOLMD. The slave travel over which the ramp takes place is simply the
142
Gem6K Series Programmer’s Guide
www.comoso.com
product of master travel and average ratio. Because the slave travel is not specified explicitly,
it is possible for arithmetic round-off errors to cause actual slave travel during a ramp to differ
from theoretical calculations. For applications in which slave distance is important, preset
segments should be used.
A preset (MCØ) Following segment will also start with the final ratio of the previous segment,
but may end in one of two ways. FOLRNF specifies the final ratio of a preset Following
segment. The only valid value for FOLRNF is zero (0). If FOLRNFØ is given before the
GOBUF, the resulting motion segment will be constructed exactly as preset Following moves
are outside of compiled profiles. In this case, the starting ratio must be zero, the final ratio
will be zero, and the maximum intermediate ratio will be given by FOLRN and FOLRD. The
relationships between ratio, master distance, and slave distance for this case are given on page
192 under the heading Master and Follower Distance Calculations. The FOLRNF command
affects only the immediately subsequent preset Following segment, and must be given
explicitly for each preset segment which is to end in zero ratio.
If FOLRNFØ is not given before the GOBUF, the segment will end with the ratio given by
FOLRN and FOLRD, and need not start with zero ratio. This type of motion segment is
constrained, however, to intermediate ratios which fall between the starting and final ratios.
Compiled profiles are built from motion segments created with the GOBUF command. That
is, the motion segments may be all Following or all non-Following, but not a mixture of
Following and non-Following.
The GOBUF command builds the appropriate type of motion segment based on the values of
FOLMAS and FOLEN during compilation. These parameters may not be changed inside a
compiled program after a GOBUF. The choice of zero or non-zero FOLMAS must be the same
during PRUN as during PCOMP (if non-zero, the value can be changed, but still must be nonzero). If a non-zero FOLMAS is given, the value of FOLEN must be the same during PRUN as
during PCOMP.
Distance
Calculations For
Compiled
Following Moves
The graph below shows 6 possibilities of ratio change profiles for preset segments, with legal
FOLMD and “D” values constrained by the requirement that the average ratio (given by
“D”/FOLMD) is between R1 and R2. If the distance is outside these ranges, in the profile used
to get from R1 to R2 over FOLMD (covering “D” slave distance), an error message will be
generated during the PCOMP command. For the graphs shown, the constraints are expressed by:
(R1 * FOLMD) <= “D” <= (R2 * FOLMD)
(R1 * FOLMD) >= “D” >= (R2 * FOLMD)
R2
R1
if R2 > R1
if R2 < R1
D > (R1 + R2) * FOLMD/2
D = (R1 + R2) * FOLMD/2
D < (R1 + R2) * FOLMD/2
Slave Distance
FOLMD
R1
D < (R1 + R2) * FOLMD/2
D = (R1 + R2) * FOLMD/2
D > (R1 + R2) * FOLMD/2
R2
Slave Distance
FOLMD
The two graphs above show the cases of R1<R2 or R1>R2, but the distance calculations of the
ramp and constant ratio portions are the same for the two cases. For each graph, the heavy
lined profile (first case) of these mimics the shape of the corresponding preset velocity change
Chapter 6. Following
143
www.comoso.com
(FOLENØ) segments in that the ramp takes place before the constant ratio portion. The second
case occurs only if the distance specified exactly matches the start and end ratios and
FOLMD1. In the third case, the ramp takes place after the constant ratio portion. In the first
and third cases, only two segments are built, and the slave and master distances traveled in
each segment are easily calculated with the simple formulas shown below. These formulas
are based on positive ratios and master and slave distances. In the construction of Following
profiles, ratios and master distances are always positive, with direction implied by the sign of
the slave distance. For calculations with negative slave distances, simply use the magnitude
of “D” in the formulas below, and invert the sign of the resulting slave distances.
Case 1 (Ramp first)
MD1 = [D-(R2*FOLMD)]/((R1-R2)/2)
MD2 = FOLMD - MD1
D1 = .5*(R1+R2)*MD1
D2 = D - D1
where MD1 = master distance during ramp
where MD2 = master distance during flat
where D1 = slave distance during ramp
where D2 = slave distance during flat
Case 2 (Ramp only)
MD1 = FOLMD
D1 = D
where MD1 = master distance during ramp
where D1 = slave distance during ramp
Case 3 (Ramp last)
MD1 = [D-(R1*FOLMD)]/((R2-R1)/2)
MD2 = FOLMD - MD1
D1 = .5*(R1+R2)*MD1
D2 = D - D1
where MD1 = master distance during ramp
where MD2 = master distance during flat
where D1 = slave distance during ramp
where D2 = slave distance during flat
Dwells and Direction Changes
Compiled profiles may incorporate changes in direction only if the preceding motion segment
has come to rest. This may be achieved for non-Following segments either by creating a
continuous segment with a goal velocity of zero, or by preceding a preset segment with VFØ.
It may be achieved for Following segments either by creating a continuous or preset segment
with a goal ratio of zero, or by preceding a preset segment with FOLRNFØ. In all cases,
motion within the profile comes to rest, although the profile is not yet complete. Even though
the motor is not moving, the axis status bit 1 (AS.1) will remain set, indicating a profile is
still underway. Only then can you change direction (using the D+ or D- command, D~ is not
allowed) within a profile. An attempt to incorporate changes in direction if the preceding
motion segment has not come to rest will result in a compilation error.
In many applications, it may be useful to create a time delay between moves. For example, a
machine cycle may require a move out, dwell for 2 seconds, and move back. To create this
dwell, a compiled GOWHEN may be used between the two moves. The code within a compiled
program may look like:
MC0
D(VAR1)
VF0
GOBUF1
GOWHEN(T=2000)
DVF0
GOBUF1
;
;
;
;
;
;
;
;
Preset incremental positioning used
Target position is in VAR1
Motion comes to rest at end of move (or use FOLRNFØ)
Create move out segment
Profile delays for 2 seconds
Return position is home (direction reversed)
Motion comes to rest at end of move (or use FOLRNFØ)
Create move back home segment
In Following applications, it may be more useful to create a master travel delay between
moves. For example, a machine cycle replacing a cam may require a move out, dwell for
2000 master counts, and move back. To create this dwell, a compiled GOBUF of zero slave
distance may be used between the two moves. The code within a compiled program may look
144
Gem6K Series Programmer’s Guide
www.comoso.com
like:
MC0
D(VAR1)
FOLMD4000
FOLRNF0
GOBUF1
D0
FOLMD2000
FOLRNF0
GOBUF1
D(VAR1)
DFOLMD4000
FOLRNF0
GOBUF1
;
;
;
;
;
;
;
;
;
;
;
;
;
;
Preset incremental positioning used
Target position is in VAR1
Move takes place over 4000 master counts
Motion comes to rest at end of move
Create move out segment
No change in target position
Dwell takes place over 2000 master counts
Motion comes to rest at end of “move” (dwell)
Create dwell segment
Return position is home (direction change implied)
Return position is home (direction reversed)
Move takes place over 4000 master counts
Motion comes to rest at end of move
Create move back home segment
Compiled Motion Versus On-The-Fly Motion
The two basic ways of creating a complex profile are with compiled motion or with on-the-fly
pre-emptive GO commands. With compiled motion, portions of a profile are built piece by
piece, and stored for later execution. Compiled motion is appropriate for profiles with motion
segments of pre-determined velocity, acceleration and distance. Compiled motion profiles
allow for shorter motion segments, which results in faster cycle times because there is no
command processing and execution delay. The axes may perform their own motion control
and coordination, freeing program flow for other tasks, such as I/O, machine control, and host
requests. The disadvantages to pre-defined compiled motion profiles are the amount of
memory use and limited run-time decision making and I/O processing.
With pre-emptive GO moves, the motion profile underway is pre-empted with a new profile
when a new GO command is issued. The new GO command constructs and launches the preempting profile. Pre-emptive GOs are appropriate when the desired motion parameters are not
known until motion is already underway.
The table below summarizes the differences between the use of compiled motion and on-thefly motion.
Command/Issue
GOBUF
Compiled Motion
Constructs motion segment and appends to
previously constructed segment
On-The-Fly Motion
N/A
PRUN
GO
Used to launch previously compiled motion
N/A
GO causes move during PCOMP
GO Constructs & launches profile,
even if moving
Direction changes
Only if previous motion segment comes to rest
(MCØ & VFØ or MC1 & VØ), else compile error
Not allowed during motion, else
AS.3Ø, ER.1Ø
Insufficient room for
AD (decel) value
Same as on-the-fly
Decel is modified (steppers);
Motion is killed, AS.3Ø (servos)
Chapter 6. Following
145
www.comoso.com
Related Commands
GOBUF
Store a Motion Segment in Compiled Memory:
The GOBUF command creates a motion segment as part of a profile and places it in a segment
of compiled memory, to be executed after all previous GOBUF motion segments have been
executed. An individual axis profile is constructed by sequentially appending motion segments
using GOBUF commands. Each motion segment may have its own distance to travel, velocity,
acceleration, and deceleration.
The end of a GOBUF motion segment in preset mode is determined by the distance or position
specified. The end of a GOBUF motion segment in continuous mode is determined by the goal
velocity specified. In both cases, the final velocity and position achieved by a segment will be
the starting velocity and position for the next segment. If either type of segment is followed by
a GOWHEN command, the segment’s final velocity will be maintained until the GOWHEN
condition becomes true.
146
PLOOP & PLN
Loop Start & Loop End (Compiled Motion only):
The PLOOP and PLN commands specify the beginning and end of an axis-specific profile loop,
respectively. All segments defined between the PLOOP and PLN commands are included
within that loop.
VF & FOLRNF
Final Velocity & Numerator of Slave-to-Master Final Ratio:
The VF and FOLRNF commands are used to designate that the motor will move the load the
distance designated in a preset GOBUF motion segment, completing the move at a final speed
of zero. The VF command is used when the Following mode is disabled (FOLENØ). The
FOLRNF command is used when the Following mode is enabled (FOLEN1).
GOWHEN
Conditional GO:
When GOWHEN is compiled in a profile, the GOWHEN condition is stored as part of that profile
instead of being executed immediately. When progress through the profile reaches the
compiled GOWHEN, AS.26 is set, and the next segment’s execution will be suspended until the
GOWHEN condition becomes true. This allows subsequent GOWHEN and GOBUF combinations
to be issued and stored, instead of overriding each other.
TRGFN
Trigger Functions:
When TRGFN is compiled in a profile, the TRGFN condition is stored as part of that profile
instead of being executed immediately. When progress through the profile reaches the
compiled TRGFN, the embedded trigger functions are assigned to that trigger. AS.26 is set if
the GOWHEN function has been assigned to the trigger, and the next segment’s execution will
be suspended until the specified trigger input goes active. This allows subsequent TRGFN,
GOWHEN, and GOBUF combinations to be issued and stored, instead of overriding each other.
PCOMP, PRUN
& PUCOMP
Compile a Program, Run a Compiled Program, & Un-Compile a Compiled Program:
The PCOMP, PRUN, and PUCOMP commands allow you to incorporate individual axis profiles
within compiled motion profiles. Compiled motion for the Gem6K series allows you to
construct complex motion programs using individual profiles (a series of GOBUF commands).
PEXE
Execute Compiled GOBUF Profile from PLC Program:
You can place a PEXE command inside a compiled PLCP program. When the PLCP program
is scanned in the PLC Scan Mode (SCANP), the PEXE command launches the specified
compiled profile in another task. For details on the PLC Scan Mode, see page 120.
Gem6K Series Programmer’s Guide
www.comoso.com
POUTA
Output During Compiled Motion Profile:
The POUTA command turns the programmable output bits on and off.
TSEG & SEG
Transfer/Display (TSEG) or Assign (SEG) the Number of Free Segment Buffers:
The TSEG command returns the number of free segment buffers in compiled memory. The
SEG command is used to assign the number of free segment buffers in compiled memory to a
variable or to make a comparison against another value.
Compiled Motion — Sample Application 1
A manufacturer has an application where wire is being wrapped onto a spindle. There is a
motor controlling the rotational speed of the spindle. Every application of the spindle requires
that the motor runs at a fast speed with a slow acceleration for the first few revolutions, a
medium speed for the next couple of revolutions, and a slower speed as the spindle gets fuller
to maintain somewhat of a constant velocity off the feed wire. The technician would like to
use an RP240 to enter the velocity and number of revolutions for each stage of winding.
Programmable outputs 1, 2 and 3 are wired to status LEDs, and should go on for the
respective stages of winding (output 1 for stage 1, etc.).
Profile
v
Distance of
third stage
Distance of
first stage
Program
Distance of
second stage
DEF PROFIL
VAR10 = 4000 * VAR4
D(VAR10)
V(VAR1)
POUTA.1-1
GOBUF1
VAR10 = 4000 * VAR5
D(VAR10)
V(VAR2)
POUTA01
GOBUF1
VAR10 = 4000 * VAR6
D(VAR10)
V(VAR3)
POUTAx01
GOBUF1
POUTA.3-0
END
DEF EXMPL1
L
DCLEAR0
DPCUR1,1
DWRITE"ENTER
VAR1 = DREAD
DCLEAR1
DPCUR1,1
DWRITE"ENTER
VAR2 = DREAD
DCLEAR1
DPCUR1,1
DWRITE"ENTER
VAR3 = DREAD
DCLEAR1
DPCUR1,1
DWRITE"ENTER
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
t
Define motion profile program
Get distance of first stage
(assuming 4000 steps/revolution)
Set distance
Set velocity of first stage
Turn output 1 on
Build motion
Get distance of second stage
Set distance
Set velocity of second stage
Turn output 1 off and output 2 on
Build motion
Get distance of third stage
Set distance
Set velocity of third stage
Turn output 2 off and output 3 on
Build motion
Turn off output 3
End motion profile program
; Define program example 1
; Continual loop of program execution
; Clear all lines on RP240 display
; Position cursor at line 1, column 1
VELOCITY STAGE 1"
; Prompt user
; Get 1st velocity from RP240 entry
; Clear line 1 on RP240 display
; Position cursor at line 1, column 1
VELOCITY STAGE 2"
; Prompt user
; Get 2nd velocity from RP240 entry
; Clear line 1 on RP240 display
; Position cursor at line 1, column 1
VELOCITY STAGE 3"
; Prompt user
; Get 3rd velocity from RP240 entry
; Clear line 1 on RP240 display
; Position cursor at line 1, column 1
REVOLUTIONS STAGE 1" ; Prompt user
Chapter 6. Following
147
www.comoso.com
VAR4 = DREAD
; Get # of windings 1st stage from RP240 entry
DCLEAR1
; Clear line 1 on RP240 display
DPCUR1,1
; Position cursor at line 1, column 1
DWRITE"ENTER REVOLUTIONS STAGE 2" ; Prompt user
VAR5 = DREAD
; Get # of windings 2nd stage from RP240 entry
DCLEAR1
; Clear line 1 on RP240 display
DPCUR1,1
; Position cursor at line 1, column 1
DWRITE”ENTER REVOLUTIONS STAGE 3" ; Prompt user
VAR6 = DREAD
; Get # of windings 3rd stage from RP240 entry
PCOMP PROFIL
; Re-compile profile with new vel/dist info
$AGAIN
; Label for repeating same profile
PRUN PROFIL
; Execute profile
DCLEAR1
; Clear line 1 on RP240 display
DPCUR1,1
; Position cursor at line 1, column 1
DWRITE"SAME DATA (1=YES,2=NO)"
; Prompt user if perform again with old data
VAR7 = DREAD
; Get response
IF(VAR7=1)
; If user wants to perform same profile
GOTO AGAIN
; perform again
NIF
; End conditional
LN
; End command execution loop
END
; End definition program example 1
; ******************************************
; * To begin, execute the EXMPL1 program
*
; ******************************************
Compiled Motion — Sample Application 2
Here’s an example of replacing a mechanical cam using a compiled Following profile. There
is evenly spaced product coming in on a feeder belt. The feeder belt may vary in speed. The
cam that you are replacing controls a push arm that will push the product into a box for
shipping. You would also like the arm to retract at a faster rate than it extends. In other
words, you would like to have a smooth push to load and a fast retract to set up for the next
product. Since this is a cam, this profile must repeat continuously for each product or master
cycle but won’t start until the first product is detected.
Product
Product
Detecter
Box
Push Arm
The feeder belt is the master and the master cycle length (space from the front of one product
to the front of the next) is 12000 master (encoder) counts on the feeder belt. The push of the
product will start 2000 counts into the master cycle. The push will take place over Gem6K
master counts, and the retract over 2000 master counts. The distance the push arm (slave)
must travel is 4000 counts. Assume the detector is wired to trigger 1A (onboard trigger input
1). Below is a graph of this Following profile.
148
Gem6K Series Programmer’s Guide
www.comoso.com
Profile
Ratio
3
2
1
D(slave) = 4000
0
Program
2000
; Setup code
FOLMAS1
FOLEN1
INFNC1-H
D(slave)
= -4000
8000
10000
12000
Master Distance
; Master is coming in on the master encoder input
; Enable Following
; Assign onboard input 1 (TRG-1A) as trigger interrupt
; Motion program
DEL EXPL2
; Delete program (in case it already exists in memory)
DEF EXPL2
; Begin definition of program example 2
1TRGFNA1
; Launch axis 1 profile upon receiving TRG-1A
; (1st product detected)
PLOOP0
; Loop continuously to mimic a mechanical cam
; Program first move - dwell
FOLRN1
; Set up ratios - numerator
FOLRD1
; and denominator
FOLMD2000
; Over a distance of 2000 master steps
D0
; slave will not move
FOLRNF0
; and end at zero ratio
GOBUF1
; Build motion
; Program second move - positive slave move
FOLMD6000
; Over a distance of 6000 master steps
D4000
; slave will move 4000 steps
FOLRNF0
; and end at zero ratio
GOBUF1
; Build motion
; Program third move - negative slave move
FOLRN3
; New ratio to accommodate larger distance of slave travel
FOLMD2000
; Over a distance of 2000 master steps
D-4000
; slave will move -4000 steps
FOLRNF0
; and end at zero ratio
GOBUF1
; Build motion
; Program last move - dwell
FOLMD2000
; Over a distance of 2000 master steps
D0
; slave will not move
FOLRNF0
; and end at zero ratio
GOBUF1
; Build motion
PLN1
; Close cam loop
END
; End program example 2
PCOMP EXPL2
; **
; Compile program EXPL2
To execute the program, enter the PRUN EXPL2 command
**
Chapter 6. Following
149
www.comoso.com
Program
Modification
Let’s now modify the constraints of the system. Let’s say that the product will be spaced roughly 12000
master counts apart. It may or may not be exactly 12000, but it will never be less than 10000 (just to
make sure the retraction finishes before the next product is detected). We can then modify the program to
wait for the product to be detected each cycle. We can also take the extra “dwell” or zero distance move
out of the end of the profile. See program below:
; Setup code
FOLMAS1
FOLEN1
INFNC1-H
; Motion program
DEL EXPL2B
DEF EXPL2B
PLOOP0
1TRGFNA1
; Master is coming in on the master encoder
; Enable Following mode
; Assign onboard input 1 (TRG-1A) as trigger interrupt
;
;
;
;
;
Delete program (in case it already exists in memory)
Begin definition of program example 2b
Loop continuously to mimic a mechanical cam
Pause axis 1 profile until TRG-1A is activated
(detect next product)
; Program first move - dwell
FOLRN1
; Set up ratios - numerator
FOLRD1
; and denominator
FOLMD2000
; Over a distance of 2000 master steps
D0
; slave will not move
FOLRNF0
; and end at zero ratio
GOBUF1
; Build motion
; Program second move - positive slave move
FOLMD6000
; Over a distance of 6000 master steps
D4000
; slave will move 4000 steps
FOLRNF0
; and end at zero ratio
GOBUF1
; Build motion
; Program third move - negative slave move
FOLRN3
; New ratio to accommodate larger distance of slave travel
FOLMD2000
; Over a distance of 2000 master steps
D-4000
; slave will move -4000 steps
FOLRNF0
; and end at zero ratio
GOBUF1
; Build motion
PLN1
; Close cam loop
END
; End program example 2b
PCOMP EXPL2B
; Compile program EXPL2B
; **********************************************************
; * To execute the program, enter the PRUN EXPL2B command *
; **********************************************************
150
Gem6K Series Programmer’s Guide
www.comoso.com
Compiled Motion — Sample Application 3
In this application, there is a wheel that stamps a logo onto the product. The product is
assumed to be entering at a constant and fixed spacing, each product is 4 inches in length with
2 inches separating each unit. The stamp wheel has a circumference of 9 inches, and must be
traveling at a 1 to 1 ratio with the product at the time of stamping. The stamp wheel must then
travel five inches in just 2 inches of master travel. There is a sensor wired to trigger A of the
Gem6K controller to detect the first product and start the cycling. At the time of the trigger
the product is 1 inch away from contact with the stamp wheel. Assume that the home position
of the slave is 0.5 inches away from a stamp. The mechanics of the system give 3000 steps of
master travel per inch and 1500 steps of slave travel per inch.
Profile
D(slave) = 3"
Ratio
D(slave) = 1"
D(slave) = 0.5"
D(slave) = 1"
D(slave) = 4"
0
0.5"
0.5"
Master
Distance
Master Cycle
As you can see above, we have a multi-tiered Following profile. By multi-tiered we mean
that ratio is changing from a non-zero value to another non-zero value. To program this
profile effectively, we will break the profile into pieces as shown with the dotted lines in the
above illustration:
Program
FOLMAS1
FOLEN1
INFNC1-H
SCLMAS3000
SCLD1500
SCALE1
;
;
;
;
;
;
Define the master as the master encoder input
Enable Following
Assign onboard input 1 (TRG-1A) as trigger interrupt
Set scaling of master steps per inch
Set scaling of slave steps per inch
Enable scaling
DEF EXMPL3
1TRGFNA1
; Start definition of example program 3
; Launch axis 1 profile when TRG-1A is activated
; Program first ramp from ratio 0 to ratio 1
FOLRD1
; Set Following ratio - denominator
FOLRN1
; Set the Following ratio at 1 to 1
FOLMD1
; Over a master distance of 1"
D0.5
; Slave will travel 0.5"
GOBUF1
; Build motion
PLOOP0
; Start the continuous loop
; Program constant ratio
FOLRN1
; At a 1 to 1 ratio
FOLMD4
; Over a master distance of 4"
D4
; Slave will travel 4"
GOBUF1
; Build motion
; Program ramp to new ratio
FOLRN3
; Go to a 3 to 1 ratio
FOLMD0.5
; Over a master distance of 0.5"
D1
; Slave will travel 1"
GOBUF1
; Build motion
Chapter 6. Following
151
www.comoso.com
; Program second constant ratio
FOLRN3
; At a 3 to 1 ratio
FOLMD1
; Over a master distance of 1"
D3
; Slave will travel 3"
GOBUF1
; Build motion
; Program ramp to lower ratio
FOLRN1
; Go to a 1 to 1 ratio
FOLMD0.5
; Over a master distance of 0.5"
D1
; Slave will travel 1"
GOBUF1
; Build motion
PLN1
; Close motion loop
; Define the exit motion
FOLRN0
; Stop slave at zero ratio (and zero velocity)
FOLMD1
; Over a master distance of 1"
D0.5
; And a slave distance of 0.5"
GOBUF1
; Build motion
END
; End definition of example program 3
PCOMP EXMPL3
; Compile example program 3
; **********************************************************
; * To execute the program, enter the PRUN EXMPL3 command *
; **********************************************************
NOTE: The GOBUF command has been added to the “Define the exit motion” portion
of the program despite the fact that an infinite loop has been programmed earlier in the
program. This is to avoid an error message when the program is compiled.
Compiled Motion — Sample Application 4
A manufacturer of stamped molds needs to make a machine which will stamp molds into a
continuous flow of extruded plastic material. The stamp must be lowered 0.5 inches into the
plastic to leave the correct impression. Because the flow is continuous, the stamp must also
move in synchronization with plastic in the direction of flow as it is lowered and raised. The
initial design approach to the machine required two axes of motion. One was needed to lower
and raise the stamp, the other to allow the stamp to follow the plastic. With the availability of
complex Following cam profiles the job can done with a single axis.
In the drawing below, the stamp is attached to a rotating arm in such a way that the stamp
remains level as the arm rotates. The length of the arm at the stamp fixture, or radius of
rotation, is exactly one inch. The arm is mounted above the plastic so that at the bottom of its
rotation (270 degrees), the stamp will be 0.5 inches into the plastic. Using trigonometry, the
horizontal and vertical positions and speeds may be calculated at other arm angles. Because
the stamp must follow the flow of the plastic, we must adjust the ratio of rotational speed to
plastic speed so that the horizontal velocity component of the arm stays at 1:1 with the plastic
while the stamp is in the plastic.
30°
V
152
Gem6K Series Programmer’s Guide
30°
V
V
www.comoso.com
The table below shows these relationships. The arm is directly driven with a servo motor
having 4096 steps per revolution. The table shows increments of 30 degrees, which is about
341 servo motor steps, or about 0.524 slave inches measured around the circumference
described by rotation of the arm. The plastic flow is measured with an encoder giving 1000
steps per inch of flow. To maintain ratios in terms of inches, FOLRD will always be 1000. The
required FOLRN value is simply the inverse of the arm’s horizontal velocity component
multiplied by the number of slave steps per inch. The corresponding ratio in terms of surface
speeds is given in parentheses. The required FOLMD is the number of master steps
corresponding to the horizontal component of slave rotation.
Arm angle,
degrees
210
240
270
300
330
Horizontal
component
(in.) = cos(deg)
-0.866
-0.500
0.000
0.500
0.866
Horizontal vel
FOLMD =
1000 * delta cos(deg) component = -sin(deg)
n/a
366
500
500
366
Required FOLRN =
-651.9/sin(deg)
0.500
0.866
1.000
0.866
0.500
1304 (2:1)
753 (1.155:1)
652 (1:1)
753 (1.155:1)
1304 (2:1)
The profile that we construct from these number is meant to approximate the inverse sine
function in the last column, but of course, will actually be a series of ramps and constant ratio
segments. Let’s review the Compiled Following Move Distance Calculations to determines
the exact shape and error in the first motion segment( from 210 to 240 degrees). First, we need
to determine if the ramp or constant ratio is first for that segment. Using ratios and distances
in inches, we have:
R1 = 2......................................... Starting ratio
R2 = 1.155.................................. Final ratio
D = (2*pi)/12 = 0.524 .................. Distance at stamp hinge
FOLMD=.366.............................. Travel along plastic
We find (R1+R2) * FOLMD/2 = 0.577, which is greater than D, so the “Ramp First”
equations apply to this segment. Let’s examine the error at the junction between the ramp and
constant ratio portion of this segment.
MD1 = [D - (R2 * FOLMD)] / ( (R1 - R2) / 2) = 0.239 master inches
D1 = 0.5 * (R1 + R2) * MD1 = 0.377 slave inches at circumference = 21.6 degrees
cos(210+21.6) - cos(210) = -0.621 - (-0.866) = 0.245 inches slave horizontal travel
error = horizontal slave travel - master travel = 0.245 - 0.239 = 0.006 inches
A similar calculation may be done for the “elbow” of the next of the next segment, and
symmetry indicates these errors will be the same between 270 and 330 degrees. The error
along intermediate points may be found with linear interpolation of ratio and master distance.
In this case, the errors fall within manufacturing tolerance. If the errors were too large, the
travel could be broken into more segments, each with exactly correct positions and ratios at
their boundaries.
So far, we have only discussed the portion of the profile which lowers and raises the stamp.
During the remainder of the profile, the arm must continue its rotation to bring the stamp to its
starting position in time for the next mold. The mold is 3 inches long, and .4 inches are needed
between molds for strength at the edges. This makes the total master cycle 3.4 inches long.
The total slave cycle must be 4096 steps, so the segments required to bring the arm around
must complete the portions of master and slave cycles not already accounted for. We will
create two segments, which divide the remaining master and slave travels in two, and are
mirror images of each other. The average ratio of these two segments must simply be slave
travel divided by master travel, i.e., (D / FOLMD). As previously determined, the FOLRN
value for the boundaries of the stamping portion of the profile is 638. From this value and the
average ratio, we can calculate the peak FOLRN value.
D = 0.5 * remaining slave = 0.5 * (4096 - 4 * 341) = 1366
FOLMD = 0.5 * remaining master = 0.5 * [1000 * (3.4 - 2 * 0.866)] = 834
peak ratio = FOLRN/1000
0.5 * (FOLRN/1000 + 1304/1000) = average ratio = D / FOLMD = 1366 / 834 = 1.638
FOLRN = 1972 (solved from above)
Chapter 6. Following
153
www.comoso.com
Finally, we need to design a segment used to create a smooth entry into the repetitive portion
of the profile. We’ll assume that the home position of the arm is at 180 degrees, so it needs to
achieve the FOLRN ratio of 1304 in 30 degrees (341 slave steps). Using the same averaging
arithmetic as above, the required master distance for the entry segment is 523 steps. A sensor
is positioned with this entry segment in mind, and wired to TRG-1A. A function to start motion
when the sensor is triggered will be imbedded inside the profile. The motion segments for the
stamping portion and recovery portions of the profile must be enclosed in a loop, and may be
programmed by picking the numbers from the table and equations above. Because the ratio
denominators are the same for all segments, and the slave distances are the same for the entry
and each of the stamping segments, these are commanded only when the values change.
Repetitive Portion of
Profile
FOLRN
1972
Each segment has
341 slave steps
1304
753
652
1000
1366
1866
2366
2732
Stamping Portion
Program
3566
4400
Recovery Portion
FOLMAS1
; Follow master encoder
FOLEN1
; Enable Following mode
INFNC1-H
; Enable trigger 1 (TRG-1A) for interrupt function
SCALE0
; Parameters are in steps
DEF STAMP
; Start program definition
TRGFNA1
; Motion profile starts upon trigger 1 (TRG-1A)
FOLRD1000
; Ratio denominator, 1ØØØ steps per inch
;define the entry segment
D341
; Distance of 341 steps is about 3Ø degrees
FOLRN13Ø4
; Goal ratio for start segment
FOLMD523
; Master distance during ramp
GOBUF1
; Build start segment
PLOOP0
; Start the continuous loop
;this profile section starts 2-to-1 ratio, or a starting FOLRN13Ø4
FOLRN753
; Goal ratio for segment
FOLMD366
; Master travel in steps for segment
GOBUF1
; Build motion segment
;the 2nd section of profile starts with the final ratio of the 1st section
FOLRN652
; Goal ratio for segment
FOLMD500
; Master travel in steps for segment
GOBUF1
; Build motion segment
;the next two sections are mirror images of the first two
FOLRN753
; Goal ratio for third segment
FOLMD500
; Master travel in steps for 3rd segment
GOBUF1
; Build motion segment
FOLRN1304
; Goal ratio for 4th segment
FOLMD366
; Master travel in steps for 4th segment
GOBUF1
; Build motion segment
;the next two sections complete the loop and are mirror images of each other
D1366
; Slave travel in recovery segments
FOLMD834
; Master travel in steps for recovery segments
FOLRN1972
; Goal ratio for ramp up segment
GOBUF1
; Build ramp up motion segment
FOLRN523
; Goal ratio for ramp down segment
GOBUF1
; Build ramp down motion segment
PLN1
; End of loop cycle
;finally, a segment to end motion
D341
; Distance of 341 steps is about 3Ø degrees
FOLRN0
; Goal ratio for end segment
FOLMD1000
; Master distance during ramp
GOBUF1
; Build end segment
END
; End of STAMP program definition
PCOMP STAMP
; Compile the program
; **********************************************************
; * To execute the program, enter the PRUN STAMP command
*
; **********************************************************
154
Master Travel
Gem6K Series Programmer’s Guide
www.comoso.com
On-the-Fly Motion (pre-emptive GOs)
While motion is in progress, you can change these motion parameters to affect a new profile:
• Acceleration (A) — s-curve acceleration is not allowed
• Deceleration (AD) — s-curve deceleration is not allowed
• Velocity (V)
• Distance (D)
• Preset or Continuous Positioning Mode Selection (MC)
• Incremental or Absolute Positioning Mode Selection (MA)
• Following Ratio Numerator and Denominator (FOLRN and FOLRD, respectively)
The motion parameters can be changed by sending the respective command (e.g., A, V, D, MC)
followed by the GO command. If the continuous command execution mode is enabled
(COMEXC1), you can execute buffered commands; otherwise (COMEXCØ), you must prefix each
command with an immediate command identifier (e.g., !A, !V, !D, !MC, followed by !GO).
The new GO command pre-empts the motion profile in progress with a new profile based on
the new motion parameter(s). On-the-fly motion changes are applicable only for motion
started with the GO command, and not for motion started with other commands such as HOM,
JOG, JOY, or PRUN.
On-the-fly motion changes are most likely to be used to change the velocity and/or goal
position of a preset move already underway. In the event that the goal position is completely
unknown before motion starts, a move may be started in continuous mode (MC1), with a switch
to preset mode (MCØ), a distance command (D), and a GO given later. In absolute positioning
mode (MA1) the new goal position given with a pre-emptive GO is explicit in the D command.
In incremental positioning (MAØ) the distance given with a new pre-emptive GO is always
measured from the at-rest position before the original GO. If a move is stopped (with the S
command), and then resumed (with the C command), this resumed motion is considered to be
part of the original GO. A subsequent distance given with a new pre-emptive GO is measured
from the at rest position before the original GO, not the intermediate stopped position.
Programming Example:
SCALE0
DEL OTF
DEF OTF
PSET0
COMEXC1
MC0
MA0
A20
AD20
V9
D500000
GO1
WAIT(PC>100000)
V4
GO1
WAIT(PC>450000)
AD5
V1
GO1
END
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
This program creates a 2-tiered profile (single-axis) that changes velocity
and deceleration at specific motor positions.
Disable scaling
Delete program (in case program is already in memory)
Begin definition of program
Set position to zero
Enable continuous command processing mode
Select preset positioning
Select incremental positioning
Set accel to 20 revs/sec/sec
Set decel to 20 revs/sec/sec
Set velocity to 9 revs/sec
Set distance to 20 revs
Initiate motion
Wait until commanded position > 100000 steps (4 revs)
Slow down for machine operation
Initiate new profile with new velocity
Wait until the motor position > 450000 steps (18 revs)
Set decel for gentle stop
Slow down for gentle stop
Initiate new profile with new velocity
End program definition
Chapter 6. Following
155
www.comoso.com
The table below summarizes the restrictions on pre-emptive GOs.
Condition
Possible?
Execute GO during MC1 & FOLENØ
Yes
Execute GO during MC1 & FOLEN1
Yes
Execute GO during MCØ & FOLENØ
Yes
Execute GO during MCØ & FOLEN1
No
Change MC setting during motion
Yes (but cannot change MC1 to MCØ during FOLEN1)
Change ENC setting during motion
No
Change FOLENØ to FOLEN1 during motion
No
Change FOLEN1 to FOLENØ during motion
Only while MC1, constant ratio, and not shifting
OTF Error Conditions
The ability to change the goal position on the fly raises the possibility of several error
conditions:
Gem6K Response
Further instructions
about handling error
conditions are provided
on page 30.
Error Conditions
The new position goal of an on-the-fly
GO cannot be reached with the
current direction, velocity, and decel.
The direction of the new goal position
is opposite that of current travel
There has not yet been an overshoot,
but it is not possible to decelerate to
the new distance from the current
velocity using the specified AD value.
Set axis status
bit #30
Set error
status bit #10
Kill motion (decelerate
at the LHAD value)
YES
YES
NO
YES
YES
YES
YES
YES
YES
RELATED STATUS COMMANDS
Axis Status — Bit #30: (this status bit is cleared with the next GO command)
AS.30 ....Assignment & comparison operator — use in a conditional expression (see pg. 25).
TASF ......Full text description of each status bit. (see “Preset Move Overshot” line item)
TAS ........Binary report of each status bit (bits 1-32 from left to right). See bit #30.
Error Status — Bit #10: The error status is monitored and reported only if you enable errorchecking bit #10 with the ERROR command (e.g., ERROR.1Ø-1). NOTE: When the error occurs, the
controller with branch to the error program (assigned with the ERRORP command). (this status bit is
cleared with the next GO command)
ER.10 ....Assignment & comparison operator — use in a conditional expression (see pg. 25).
TERF ......Full text description of each status bit. (see “Preset Move Overshot” line item)
TER ........Binary report of each status bit (bits 1-32 from left to right). See bit #10.
Scenarios
Scenario #1: OTF change of velocity and
v
distance, where new commanded distance (D2) is
greater than the original distance (D1) that was
pre-empted [D2 >D1]. The distances are the areas
under the profiles, starting at t0 for both. If the
original move had continued, D1 would have been
reached at time t1. D2 is reached at time t2.
D2
D1
t0
156
Gem6K Series Programmer’s Guide
t1
t2
t
www.comoso.com
Scenario #2: OTF change of distance, where
v
new commanded distance (D2) is less than the
original distance (D1) that was pre-empted [D2 <
D1]. In this example, the position where the OTF
change was entered is already beyond D2 (or D2
can not be reached with the commanded
deceleration). The result is an error and motion is
killed (decel at the LHAD value) and TAS bit #30
and TER bit #10 are set.
Scenario #3: OTF change of velocity. Note that
motion must continue for a longer time at the
reduced velocity to reach the original
commanded distance than if it had continued at
the original velocity (t2 > t1).
D2
D1
t0
t
t1
v
D1
D1
t0
t1
t2
t
On-The-Fly Motion — Sample Application
A manufacturer of three products wishes to produce a “sampler-pak” package which will
contain a few of each of his products. The products all have the same width and length, but
are 3, 4, and 5 inches high respectively. The 3 products are fed from individual lines into a
common conveyor, and arrive at a stacking and wrapping station. At this station, a tray
accepts a product and must have moved down by that product’s height by the time the next
product arrives. This means that each time a new product arrives, the velocity of the tray must
be changed to match the height of that product. Although product spacing will be regular, the
ordering of product type on the common conveyor will be random, due to variations in the
input lines. Also, a finished sampler-pak should contain 5 products or be at least 18 inches
high, whichever occurs first. This means that the total move distance of the tray will be
unknown until the last product arrives. When the last product is stacked, an output is asserted
which will pause the conveyor and start the wrapping process. When wrapping is complete,
the sampler-pak is removed from the tray, and the tray returns to the starting position.
The basic problems in this application are that the move distance is not known until near the
end, and the velocity must change on the fly. As the products approach the tray, they are
detected with a near vertical arrangement of three sensors. Products of heights 3, 4, and 5
inches are detected by 1, 2, or all 3 sensors respectively. Input 1 always detects a product, and
switches last, so that the others will be stable. When each product is identified, the motion
profile is modified accordingly.
Chapter 6. Following
157
www.comoso.com
Sensors
3
2
3"
4"
4"
5"
3"
4"
5"
1
3"
3"
Program
(portion only)
VAR1=0
VAR2=0
VAR3=0
A10
MC0
WHILE(VAR1<5 AND VAR2<18)
WAIT(IN.1=B1)
VAR1=VAR1+1
IF(IN.2=B1)
IF(IN.3=B1)
VAR3=5
VAR2=VAR2+5
ELSE
VAR3=4
VAR2=VAR2+4
NIF
ELSE
VAR3=3
VAR2=VAR2+3
NIF
V(VAR3)
D(VAR2)
WAIT(IN.1=B0)
GO1
NWHILE
WAIT(AS.1=B0)
OUT1
158
Gem6K Series Programmer’s Guide
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
Initialize product count
Initialize move distance variable
Initialize velocity
Moderate acceleration
Start with preset move
Loop until cycle complete
Wait for start of next product
(onboard input 1 is activated)
Update product count
If not a 3" product
If it is a 5" product
Set velocity
Update distance
If not 5", must be 4"
Set velocity
Update distance
End of 5" case check
3" inch case
Set velocity
Update distance
End of 3" case check
New velocity
New distance
Wait for end of this product
Implement new distance and velocity
Sampler-pak completed product detection
Wait for move to complete
Output to indicate stacking complete
www.comoso.com
Registration
A “registration input” is
a trigger input assigned
the “trigger interrupt”
function with the
INFNCi-H command.
When a registration input is activated, the motion profile currently being executed is replaced
by the registration profile with its own distance (REG), acceleration (A & AA), deceleration (AD
& ADA), and velocity (V) values. The registration move may interrupt any preset, continuous,
or registration move in progress.
The registration move does not alter the rest of the program being executed when registration
occurs, nor does it affect commands being executed in the background if the controller is
operating in the continuous command execution mode (COMEXC1).
Registration moves will not be executed while the motor is not performing a move, while in
the joystick mode (JOY1), or while decelerating due to a stop, kill, soft limit, or hard limit.
How to Set up a Registration Move
Before you can initiate a registration move, you must program these elements (refer also to the
programming examples below):
1. Configure one of the trigger inputs (TRG-nA [#1] or TRG-nB [#2]) to function as a
trigger interrupt input; this is done with the INFNCi-H command, where “i” is the
input bit number representing the targeted trigger input. Note that the “Master Trigger”
input may not be used for registration.
☞
ENCCNT: Encoder
capture options for
stepper axes are
discussed on page 85.
2. Specify the distance of the registration move with the REG command. For servo axes,
the distance refers to the encoder position. For stepper axes, the distance refers to
commanded position if ENCCNT0 (default setting) or encoder position if ENCCNT1.
3. Enable the registration function with the RE command. Registration is performed only
when the registration function is enabled, and with a non-zero distance specified in the
respective axis-designation field of the REG command.
NOTE: The registration move is executed using the A, AA, AD, ADA, and V values that
were in effect when the REG command was entered.
Registration Move Accuracy
(see also Registration Move Status below)
The accuracy of the registration move distance specified with the REG command is ±1 count
(servo axes: encoder count; stepper axes: commanded count if ENCCNT0 or encoder count if
ENCCNT1).
RULE OF THUMB: To prevent position overshoot, make sure the REG distance is greater
than 4 ms multiplied by the incoming velocity.
The lapse between activating the registration input and commencing the registration move
(this does not affect the move accuracy) is less than one position sample period (2 ms).
The REG distance will be scaled by the distance scale factor (SCLD value) if scaling is
enabled (SCALE1). See page 67 for details on scaling.
Chapter 6. Following
159
www.comoso.com
Preventing Unwanted Registration Moves (methods)
• Registration Input Debounce: Registration Input Debounce: By default, the registration
inputs are debounced for 2 ms before another input on the same trigger is recognized.
(The debounce time is the time required between a trigger's initial active transition and
its secondary active transition.) Therefore, the maximum rate that a registration input
can initiate registration moves is 500 times per second. If your application requires a
shorter debounce time, you can change it with the TRGLOT command.
• Registration Single-Shot: The REGSS command allows you to program the Gem6K
controller to ignore any registration commands after the first registration move has
been initiated. Refer to the REGSS command description for further details and an
application example.
• Registration Lockout Distance: The REGLOD command specifies what distance an axis
must travel before any trigger assigned as a registration input will be recognized. Refer
to the Sample Application 3 below.
Registration Move Status & Error Handling
Axis Status — Bit #28: This status bit is set when a registration move has been initiated by
any registration input (trigger). This status bit is cleared with the next GO command.
AS.28 .......Assignment & comparison operator — use in a conditional expression (see pg. 26).
TASF..........Full text description of each status bit. (see “Reg Move Commanded” line item)
TAS ............Binary report of each status bit (bits 1-32 from left to right). See bit #28.
Axis Status — Bit #30: If, when the registration input is activated, the registration move
profile cannot be performed with the specified motion parameters, the Gem6K controller will
kill the move in progress and set axis status bit #30. This status bit is cleared with the next GO
command.
AS.3Ø .......Assignment & comparison operator — use in a conditional expression (see pg. 26).
TASF..........Full text description of each status bit. (see “Preset Move Overshot” line item)
TAS ............Binary report of each status bit (bits 1-32 from left to right). See bit #30.
Further instructions
about handling error
conditions are provided
on page 30.
Error Status — Bit #10: This status bit may be set if axis status bit #30 is set. The error
status is monitored and reported only if you enable error-checking bit #10 with the ERROR
command (e.g., ERROR.1Ø-1). NOTE: When the error occurs, the controller will branch to
the error program (assigned with the ERRORP command). This status bit is cleared with the
next GO command.
ER.1Ø .......Assignment & comparison operator — use in a conditional expression (see pg. 26).
TERF..........Full text description of each status bit. (see “Preset Move Overshot” line item)
TER ............Binary report of each status bit (bits 1-32 from left to right). See bit #10.
Trigger Status — Bits #1-17: Trigger status bits are set when a registration move has been
initiated by trigger inputs A or B, or with the TRIG-M (master trigger) input. This also
indicates that the position has been captured. As soon as the captured information is
transferred or assigned/compared (see page 99), the respective trigger status bit is cleared (set
to Ø).
TRIG..........Assignment & comparison operator — use in a conditional expression.(see pg. 26).
TTRIG .......Binary report of each status bit (bits 1-17 from left to right). From left to right the bits
represent trigger A and B, the 17th bit is master trigger M (the “MASTER TRIG” input
terminal) — see page 91.
160
Gem6K Series Programmer’s Guide
www.comoso.com
Registration — Sample Application 1
In this example, two-tiered registration is achieved (see illustration below). While the motor
is executing it’s 50,000-unit move, trigger input 1 (TRG-1A) is activated and executes
registration move A to slow the load’s movement. An open container of volatile liquid is then
placed on the conveyor belts. After picking up the liquid and while registration move A is
still in progress, trigger input 2 (TRG-1B) is activated and executes registration move B to
slow the load to gentle stop.
DEL REGI1
DEF REGI1
INFNC1-H
INFNC2-H
A20
AD40
V1
1REGA4000
A5
AD2
V.5
1REGB13000
RE10
A50
AD50
V10
D50000
GO10
END
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
Delete program (in case program already resides in memory)
Begin program definition
Define trigger input 1 (TRG-1A) as trigger interrupt input
Define trigger input 2 (TRG-1B) as trigger interrupt input
Set acceleration on axis 1 to 20 units/sec2
Set deceleration on axis 1 to 40 units/sec2
Set velocity on axis 1 to 1 unit/sec
Set TRG-1A's registration distance on axis 1 to 4000 units
(registration A move will use the A, AD, & V values above)
Set acceleration on axis 1 to 5 units/sec/sec
Set deceleration on axis 1 to 2 units/sec/sec
Set velocity on axis 1 to 0.5 units/sec
Set TRG-1B's registration distance on axis 1 to 13,000 units
(registration B move will use the A, AD, & V values above)
Enable registration on axis 1 only
Set acceleration to 50 units/sec/sec on axis 1
Set deceleration to 50 units/sec/sec on axis 1
Set velocity to 10 unit/sec on axis 1
Set distance to 50000 units on axis 1
Initiate motion on axis 1
End program definition
1st Registration mark
(TRG-1A) occurs
v
10
2nd Registration mark
(TRG-1B) occurs
8
6
Pick up
container
here
4
2
0
0
10,000
20,000
Chapter 6. Following
D
161
www.comoso.com
Registration — Sample Application 2
A user has a line of material with randomly spaced registration marks. It is known that the
first mark must initiate a registration move, and that each registration move cannot be
interrupted or the end product will be destroyed. Since the distance between marks is random,
it is impossible to predict if a second registration mark will occur before the first registration
move has finished.
DEL REGI2
DEF REGI2
INFNC1-H
RE1
V2
REGA20000
MC1
V1
GO1
END
v
;
;
;
;
;
;
;
;
;
;
1st Registration
mark occurs
Delete program (in case program already resides in memory)
Begin program definition
Trigger capture mode for trigger 1 (TRG-A)
Enable registration
Set registration move to a velocity of 2 rps
and a distance of 20000 steps
Start a mode continuous
move at a velocity of 1 rps
Initiate motion
End program definition
2nd Registration
mark occurs
2
The first registration move
is pre-empted by a second
registration input.
1
0
t
In order to stop the second registration from occurring, REGSS can be used:
DEL REGI2b
DEF REGI2b
INFNC1-H
RE1
V2
REGA20000
REGSS1
MC1
V1
GO1
END
v
1st Registration
mark occurs
2
1
0
162
;
;
;
;
;
;
;
;
;
;
;
Gem6K Series Programmer’s Guide
Delete program (in case program already resides in memory)
Begin program definition
Trigger capture mode for trigger 1 (TRG-A)
Enable registration
Set registration move to a velocity of 2 rps
and a distance of 20000 steps
Enable registration single shot mode
Start a mode continuous
move at a velocity of 1 rps
Initiate motion
End program definition
2nd Registration
mark occurs
Because of REGSS, the
first registration move is
NOT pre-empted by the
second registration input.
The registration “single
shot” will be reset when
you issue a new motion
command (GO, PRUN, etc.).
t
www.comoso.com
Registration — Sample Application 3
A print wheel uses registration to initiate each print cycle. From the beginning of motion, the
controller should ignore all registration marks before traveling 2000 steps. This is to ensure
that the unit is up to speed and that the registration mark is a valid one.
DEL REGI3
DEF REGI3
INFNC1-H
RE1
V2
REGA2500
REGLOD2000
MC1
V1
GO1
END
;
;
;
;
;
;
;
;
;
;
;
Delete program (in case program already resides in memory)
Begin program definition
Trigger capture mode for trigger 1 (TRG-A)
Enable registration
Set registration move to a velocity of 2 rps
and a distance of 2500 steps
Set registration lockout distance to 2000 steps
Start a mode continuous
move at a velocity of 1 rps
Initiate motion
End program definition
1st Registration mark occurs
after 1500 steps, but the
registration
move does not
occur because
the lockout
distance is set
to 2000 steps.
v
2
2nd Registration
mark occurs after
3000 steps.
1
0
t
Synchronizing Motion (GOWHEN and TRGFN operations)
GOWHEN and TRGFN allow you to synchronize the execution of motion and other events:
•
•
GOWHEN — synchronize execution of the subsequent start-motion command (GO, GOL,
FGADV, FSHFC, or FSHFD) to:
- Position (commanded, feedback device, motor, master, slave, Following shift)
- Master cycle number
- Input status
- Time delay (dwell)
TRGFN:
- Suspend execution of the next start-motion command (GO, GOL, FGADV, FSHFC,
or FSHFD) until the specified trigger input goes active.
- Suspend beginning a new Following master cycle until the specified trigger
input goes active.
Conditional “GO”s (GOWHEN)
The GOWHEN command is used to synchronize a motion profile with a specified position
count, input status, dwell (time delay), or master cycle number. Command processing does not
wait for the GOWHEN conditions (relational expressions) to become true during the GOWHEN
command. Rather, the motion from the subsequent start-motion command (GO, GOL, FGADV,
FSHFC, and FSHFD) will be suspended until the condition becomes true.
Start-motion type commands that cannot be synchronized using the GOWHEN command are:
HOM, JOG, JOY, and PRUN. A preset GO command that is already in motion can start a new
profile using the GOWHEN and GO sequence of commands. Continuous moves (MC1) already
in progress can change to a new velocity based upon the GOWHEN and GO sequence. Both
preset and continuous moves can be started from rest with the GOWHEN and GO sequence.
Chapter 6. Following
163
www.comoso.com
GOWHEN
Syntax
GOWHEN(expression,expression,expression,...)
Relational Expression Syntax:
(<left operand> <relational operator> <right operand>)
Possible Operators:
Possible Operators:
>=
<=
=
>
<
FB....... Feedback device position
LIM..... Limit input state
NMCY... Master cycle number
PC....... Commanded position
PE....... Encoder position
PMAS... Master position
PSLC... Slave position
PSHF... Following shift
IN....... Input state
T......... Dwell (in milliseconds)
Possible Operators:
• Numeric variables
(VAR or VARI)
• Decimal constant
• Binary value (b___)
for the IN and LIM
operators only
EXAMPLES
GOWHEN(PE>4ØØØØ)
GOWHEN(IN.6=b1)
GOWHEN(PMAS>255)
;
;
;
;
suspend next GO
suspend next GO
suspend next GO
master distance
until encoder position > 4ØØØØ
until onboard input #6 is activated (b1)
until the master has traveled 255
units
Using the numeric variable operand: VAR will be sampled only once, at the moment the
GOWHEN command is executed. To use other right-hand side data sources, precede the
GOWHEN command with a command that loads a variable with the data source desired and
then use that variable in the GOWHEN expression.
SCALING
If scaling is enabled (SCALE1), the right-hand operand is multiplied by SCLD if the left-hand
operand is FB, PC, PE, PSLV, or PSHF. The right-hand operand is multiplied by the SCLMAS
value if the left-hand operand is PMAS. (The SCLD or SCLMAS values used correlate to the
axis specified with the variable–e.g., a GOWHEN expression with PE scales the encoder
position by the SCLD value.)
GOWHEN
Status
Axis Status — Bit #26: Bit #26 is set when motion has been commanded by a GO, GOL,
FGADV, FSHFC, or FSHFD command, but is suspended due to a pending GOWHEN condition. This
status bit is cleared when the GOWHEN condition is true or when a stop (!S) or kill (!K or ^K)
command is executed. The GOWHEN command can be cleared using S or K command
(e.g., !S11XØ or !KØXX1).
AS.26 .......Assignment & comparison operator — use in a conditional expression (see page 26).
TASF..........Full text description of each status bit. (see “Gowhen is Pending” line item)
TAS ............Binary report of each status bit (bits 1-32 from left to right). See bit #26.
Axis Status — Bit #29: Bit #29 is set when the input state of position relationship specificed
in the GOWHEN expression was already true when the subsequent GO, GOL, FGADV, FSHFC or
FSHFD command was executed.
AS.29 .......Assignment & comparison operator — use in a conditional expression (see page 26).
TASF..........Full text description of each status bit. (see “Gowhen Error” line item)
TAS ............Binary report of each status bit (bits 1-32 from left to right). See bit #29.
Further instructions
about handling error
conditions are
provided on page 30.
164
Error Status — Bit #14: Bit #14 is set if the input state or position relationship specified in
the GOWHEN expression was already true when the subsequent GO, GOL, FGADV, FSHFC, or
FSHFD command is issued. The error status is monitored and reported only if you enable errorchecking bit #14 with the ERROR command (e.g., ERROR.14-1). NOTE: When the error
occurs, the controller with branch to the error program (assigned with the ERRORP command).
Gem6K Series Programmer’s Guide
www.comoso.com
ER.14 .......Assignment & comparison operator — use in a conditional expression (see page 26).
TERF..........Full text description of each status bit. (see “GOWHEN condition true” line item)
TER ............Binary report of each status bit (bits 1-32 from left to right). See bit #14.
GOWHEN ...
On A Trigger Input
If you wish motion to be triggered with a trigger input, use the TRGFNc1 command. The
TRGFNc1 command executes in the same manner as the GOWHEN command, except that
motion is executed when the specified trigger input “c” is activated.. For more information,
refer to Trigger Functions below.
GOWHEN
A WAIT will cause the controller program to halt program flow (except for execution of
immediate commands) until the condition specified is satisfied. Common uses for this function
include delaying subsequent I/O activation until the master has achieved a required position or
an object has been sensed.
VS
WAIT
By contrast, a GOWHEN will suspend the motion profile until the specified condition is met. It
does not affect program flow. If you wish motion to be triggered with a trigger input, use the
TRGFNc1 command. The TRGFNc1 command executes in the same manner as the GOWHEN
command, except that motion is executed when the specified trigger input (c) is activated (see
Trigger Functions below for details). In addition, GOWHEN expressions are limited to the
operands listed above; WAIT can use additional operands such as FS (Following status) and
VMAS (velocity of master).
Factors Affecting
GOWHEN Execution
If a second GOWHEN command is executed before a start-motion command (GO, GOL, FSHFC,
or FSHFD), then the first GOWHEN is over-written by the second GOWHEN command. (GOWHEN
commands are not nested.) An error is not generated when a GOWHEN command is over-written
by another GOWHEN.
While waiting for a GOWHEN condition to be met and a start-motion command has been
issued, if a second GOWHEN command is encountered, then the first sequence is disabled and
another start-motion command is needed to re-arm the second GOWHEN sequence.
A new GOWHEN command must be issued for each start-motion command (GO, GOL, FGADV,
FSHFC, or FSHFD). That is, once a GOWHEN condition is met and the motion command is
executed, subsequent motion commands will not be affected by the same GOWHEN command.
If the GOWHEN and start-motion commands are issued, the motion profile is delayed until the
GOWHEN condition is met. If a second start-motion command is encountered, the second startmotion command will override the GOWHEN command and start motion. If this override
situation is not desired, it can be avoided by using a WAIT condition between the first startmotion command and the second start-motion command.
It is probable that the GOWHEN command, the GO command, and the GOWHEN condition
becoming true may be separated in time, and by other commands. Situations may arise, or
commands may be given which make the GOWHEN invalid or inappropriate. In these cases, the
GOWHEN condition is cleared, and any motion pending the GOWHEN condition becoming true
is canceled. These situations include execution of the JOG, JOY, HOM, PRUN, and DRIVEØ
commands, as well motion being stopped due to hard or soft limits, a drive fault, an
immediate stop (!S), or an immediate kill (!K or ^K).
☞
GOWHEN in Compiled
Motion (Compiled
Motion is discussed on
page 139)
Sample
Gem6K Code
When used in a compiled program, a GOWHEN will pause the profile in progress (motion
continues at constant velocity) until the GOWHEN condition evaluates true. When executing a
compiled Following profile, the GOWHEN is ignored on the reverse Following path (i.e., when
the master is moving in the opposite direction of that which is specified in the FOLMAS
command). A compiled GOWHEN may require up to 4 segments of compiled memory storage.
In the example below, the motor must start motion when input #2 signals a safe condition.
While waiting, the program must be monitoring inputs and serving other system requirements,
so a WAIT statement cannot be used; instead, a GOWHEN and GO sequence will delay the move
profile of axis 2.
Chapter 6. Following
165
www.comoso.com
MC0
D20
COMEXC1
V1
A100
GOWHEN(IN.2=b1)
GO
;
;
;
;
;
;
;
;
;
;
;
Set to preset move mode
Set distance end-point
Enable continuous command execution mode
Set velocity
Set acceleration
Delay profile. When expression is true (input #2 is
low) start motion.
Command to move. Motor will not start until
conditions in the GOWHEN statement are true.
Command processing does not wait, so other system
functions may be performed.
Trigger Functions (TRGFN)
The Trigger Functions command (TRGFN) allows you to assign additional functions to trigger
inputs that have been defined as “trigger interrupt” inputs (INFNCi-H):
TRGFNc bb
Start New Master Cycle (FMCNEW) function
Conditional GO (GOWHEN) function
Trigger letter. Two triggers are available (A or B).
The “Master Trigger” (letter M) may also be used.
• “Conditional GO” Function (TRGFNc1x): Suspend execution of the next start-motion
command until specified trigger input “c” goes active. Start-motion commands are listed
below. Refer to page 163 or to the GOWHEN command description for additional details.
- GO (standard command to begin motion)
- FGADV (begin geared advance – for Following motion)
- FSHFC (begin continuous shift – for Following motion)
- FSHFD (begin preset shift – for Following motion)
Axis status bit #26 (reported with TASF, TAS, or AS) is set to one (1) when there is a
pending “Conditional GO” condition initiated by a TRGFN command; this bit is cleared
when the trigger is activated or when a stop command (S) or a kill command (K) is issued.
If you need execution to be triggered by other factors (e.g., input state, master position,
encoder position, etc.) use the GOWHEN command.
• “New Master Cycle” Function (TRGFNcx1): This is equivalent to executing the FMCNEW
command. When specified trigger input “c” goes active, the controller begins a new
Following master cycle. For more information on master cycles, refer to page 182 or to
the FMCNEW command description.
These trigger functions are cleared once the function is complete (trigger input is activated). To
use the trigger to perform a GOWHEN function again, the TRGFN command must be given again.
Sample
Gem6K Code
INFNC1-H
INFNC2-H
TRGFNBx1
TRGFNB1x
GO1
166
;
;
;
;
;
;
;
;
Gem6K Series Programmer’s Guide
Define input #1 (TRG-A) as a trigger interrupt input
Define input #2 (TRG-B) as a trigger interrupt input
When TRG-1B goes active, motor will begin a new
master cycle
When TRG-2B goes active, motor will execute the move
commanded with the GO command.
The move is commanded, but will not execute
until trigger 2B goes active.
www.comoso.com
Following
6
CHAPTER SIX
Following
IN THIS CHAPTER
This chapter will help you understand Ratio Following:
• Introduction to Ratio Following ......................................................................168
• Implementing Ratio Following .......................................................................170
• Master Cycle Concept .....................................................................................182
• Technical Considerations for Following .........................................................186
• Troubleshooting for Following .......................................................................196
• Following Commands (list).............................................................................198
www.comoso.com
Ratio Following – Introduction
As part of its standard features, the Gem6K Series Drive/Controller family allows you to solve
applications requiring Ratio Following.
Compiled Profiles
You can pre-compile
Following profiles
(saves processing
time). See page 142
for details.
Ratio Following is, essentially, controlled motion based on the measurement of external
motion. This includes concepts such as an electronic gearbox, trackball, follower axis feed-tolength, as well as complex changes of ratio as a function of master position. Ratio Following
can include continuous, preset, and registration-like moves in which the velocity is replaced
with a ratio.
The follower axis may follow in either direction and change ratio while moving, with phase
shifts allowed during motion at otherwise constant ratio. Ratio changes or new moves may be
dependent on master position or based on receipt of a trigger input. Also, a follower axis may
perform Following moves or normal time-based moves in the same application because
Following can be enabled and disabled at will. Product cycles (operations which repeat with
periodic master travel) can be easily specified with the master cycle concept (see page 182).
In Ratio Following, acceleration ramps between ratios will take place over a user-specified
master distance. Product cycles can be easily specified with the master cycle concept.
This chapter highlights the capabilities of the Gem6K Following features and provides
application examples. If you need more details on the operation or syntax of a particular
command, please refer to the Gem6K Series Command Reference.
Before delving into the specifics of Ratio Following, read on to gain a basic understanding of
how the Gem6K follows.
What can be a master?
The Gem6K can be made to “follow” any of the master input (“master”) sources listed in the
table below.
• Incremental encoder. The encoder can be the axis-related “ENCODER” port on a stepper,
or it can be the “MASTER ENCODER” port.
• Analog input (servo axes only). This requires an ANI SIM be installed on an expansion
I/O brick (see your product’s Installation Guide for instructions). ANI SIMs and
expansion I/O bricks are sold separately.
• Internal count source (a “virtual master” option)
• Internal sine wave source (a “virtual master” option)
• Integer variable (VARI)
A servo axis may not follow its own feedback device input (encoder or analog input).
A stepper axis may follow its own encoder input, as long as that axis does not use the Encoder
Stall Detect feature (ESTALL1 mode).
For instructions on assigning a master for a particular follower axis, refer to Define the
Master and Follower (page 170), or refer to the FOLMAS command description in the Gem6K
Series Command Reference.
168
Gem6K Series Programmer’s Guide
www.comoso.com
Following Status (TFSF, TFS & FS Commands)
Many of the Following features described in this document have associated status bits that can be displayed
(with the TFSF and TFS commands) or used in assignment or comparison operations (with the FS operator).
The portions of this document which describe those features also summarize the related status bits.
FS Bit
Function (YES = 1; NO = Ø)
1....... Follower in Ratio Move ..... A Following move is in progress.
2....... Ratio is Negative .............. The current ratio is negative (i.e., follower counts counting in the opposite direction from master).
3....... Follower Ratio Changing .. The follower is ramping from one ratio to another (including a ramp to or from zero ratio).
4....... Follower At Ratio .............. The follower is at constant non-zero ratio.
Bits 1-4 indicate the status of the follower axis in Following motion.
* 5....... FOLMAS Active.................. A master is specified with the FOLMAS command.
* 6....... FOLEN Active .................... Following has been enabled with the FOLEN command.
* 7....... Master is Moving .............. The specified master is currently in motion.
8....... Master Dir Neg ................. The current master direction is negative. (Bit must be cleared to allow Following move in preset
mode—MCØ).
Bits 5-8 indicate the status required for Following motion (i.e., a master must be assigned, Following must be enabled,
the master must be moving, and for many features, the master direction must be positive).
Unless the master is a commanded position of another axis, minor vibration of the master will likely cause bits 7-8 to
toggle on and off, even if the master is nominally “at rest”. These bits are meant primarily as a quick diagnosis for the
absence of master motion, or master motion in the wrong direction. Many features require positive master counting to
work properly.
9....... OK to Shift ........................ Conditions are valid to issue shift commands (FSHFD or FSHFC).
10....... Shifting now ...................... A shift move is in progress.
11....... Shift is Continuous............ An FSHFC-based shift move is in progress.
12....... Shift Dir is Neg.................. The direction of the shift move in progress is negative.
Bits 9-12 indicate the shift status of the follower. Shifting is super-imposed motion, but if viewed alone, can have its
own status. In other words, bits 10-12 describe only the shifting portion of motion.
13....... Master Cyc Trig Pend....... A master cycle restart is pending the occurrence of the specified trigger.
14....... Mas Cyc Len Given .......... A non-zero master cycle length has been specified with the FMCLEN command.
15....... Master Cyc Pos Neg......... The current master cycle position (PMAS) is negative. This could be by caused by a negative initial
master cycle position (FMCP), or if the master is moving in the negative direction.
16....... Master Cyc Num > 0......... The master position (PMAS) has exceeded the master cycle length (FMCLEN) at least once, causing
the master cycle number (NMCY) to increment.
Bits 13-16 indicate the status of master cycle counting. If a Following application is taking advantage of master cycle
counting, these bits provide a quick summary of some important master cycle information.
17....... Mas Pos Prediction On..... Master position prediction has been enabled (FPPEN).
18....... Mas Filtering On ............... A non-zero value for master position filtering (FFILT) is in effect.
19....... <RESERVED>
20....... <RESERVED>
Bit 17 and 18 indicate the status of master position measurement features.
21....... <RESERVED>
22....... <RESERVED>
23....... OK to do FGADV move...... OK to do Geared Advance move (master assigned with FOLMAS, Following enabled with FOLEN, and
follower axis is either not moving, or moving at constant ratio in continuous mode).
24....... FGADV move underway .... Geared Advance move profile is in progress.
Bits 23 and 24 indicate the status of a Geared Advance move.
25....... <RESERVED>
26....... FMAXA/FMAXV limited........ The present Following move profile is being limited by FMAXA or FMAXV.
27....... <RESERVED>
28....... <RESERVED>
Bits 23 and 24 indicate the status of a Geared Advance move.
* All these conditions must be true before Following motion will occur.
Chapter 7. Multi-Tasking
169
www.comoso.com
Implementing Ratio Following
This section covers the basic elements of implementing Ratio Following:
•
•
•
•
•
Applying Following setup parameters
Move profiles
Performing phase shifts (FSHFC and FSHFD)
Geared advanced (FGADV)
Application scenarios:
- Electronic gearbox
- Trackball
Ratio Following Setup Parameters
Prior to executing a Following move, there are several setup parameters that must be
specified. These parameters may be established:
Programming
examples — see
application examples
later in this chapter.
Following Status
(see TFSF, TFS and FS
commands)
•
•
•
•
•
Define the master and follower (FOLMAS)
Define master & follower scaling factors (SCLMAS, SCLA, SCLD, and SCLV) – if required
Define the follower-to-master Following ratio (FOLRN and FOLRD)
Define the master distance (FOLMD) – define scaling first
Enable the Following Mode (FOLEN)
Following Status bits 5-8 (see table below) are meant to indicate the status required for
Following motion (i.e., a master must be assigned, Following must be enabled, the master must
be moving, and for many features, the master direction must be positive).
Bits 7-8 represent master motion and master direction respectively. Unless the master is a
commanded position of another axis, it is likely that minor vibration of the master will cause
these bits to toggle on and off, even if the master is nominally “at rest”. These bits are meant
primarily as a quick diagnosis for the absence of master motion, or master motion in the wrong
direction. Many features require positive master counting to work properly.
Bit #
Define the Master
and Follower;
(FOLMAS)
Function (yes = 1; no = Ø)
5
FOLMAS Active ................A master is specified with the FOLMAS command.
6
FOLEN Active ..................Following has been enabled with the FOLEN command.
7
Master is Moving.............The specified master is currently in motion.
8
Master Dir Neg................The current master direction is negative. (bit must be cleared to
allow Following move in preset mode–MCØ).
The FOLMAS command defines the masters and the followers. The command syntax is:
Follower
Axis
FOLMAS <+ii>
Format for master assignment to follower:
Sign Bit
Master source axis # (optional)
Master source selection
170
Gem6K Series Programmer’s Guide
<+ii>
www.comoso.com
• Sign bit (±): Specifies the count direction of the master source which will result in
positive master travel counts. The sign bit is not meant to be used simply to change the
direction of follower motion. That function can be done with the sign of the D command.
Rather, the sign bit is used to allow forward motion of the physical master (e.g., conveyor
belt, rotating wheel, or the continuous feed of material or product) to result in positive
counts. Several features described later in this document require increasing master counts
for proper operation. These include Following motion in preset positioning mode (MCØ) ,
master cycle counting, and executing GOWHEN based on master cycle position.
• Master source axis number (1st i): Selects the axis number of the master source. This
number is not required when selecting the Master Encoder as the master source. . If the
master source is “8” (VARI), this represents the integer variable (VARI) number.
• Master source selection (2nd i): Selects the master source (according to the master source
axis number). The options, selected by their respective number, are:
1.... Incremental encoder connected to one of the axis-related “ENCODER” ports, or the
“MASTER ENCODER” port. If the master encoder is selected, the master source
input number must be omitted from the syntax.
2.... Analog input (servo axes only). This requires an ANI SIM be installed on an
expansion I/O brick (see your product’s Installation Guide for instructions), and
the ANI input must be designated as a master input source with the ANIMAS
command. ANI SIMs and expansion I/O bricks are sold separately.
5.... Internal count source (see Following a Virtual Master below for details)
6.... Internal sine wave source (see Following a Virtual Master below for details)
8.... VARI variable (see Following an Integer Variable below for details)
NOTES
• Servo controllers: The follower axis cannot use its own commanded position or its
currently selected feedback device (encoder or ANI) as the master input.
• Stepper controllers: A follower axis that is using the Stall Detect mode (ESTALL1) cannot
use its own encoder as the master input.
• If scaling is enabled (SCALE1), the measurement of the master is scaled by the SCLMAS
value.
As an example, suppose the Master Encoder input is to be the master input for follower axis 1,
and forward travel of the physical master (e.g., conveyor belt) results in negative counts on
the Master Encoder. Given these operating constraints, you would use the FOLMAS-1
command.
The default axis follower setting is disabled. If you do not want the axis to be a follower,
simply leave it not configured (e.g., FOLMAS+11 command configures axis #1 as a follower
to encoder #1;). If an axis is currently configured as a follower, you can disable its follower
status by putting a zero (Ø) in the parameter field (e.g., the FOLMASØ command disables axis
1 from being a follower axis).
As soon as the master/follower configuration is specified with the FOLMAS command, a
continuously updated relationship is maintained between the follower’s position and the
master’s position. The update period is 2 ms.
FOLMAS Setting Not Saved in Non-Volatile Memory
The FOLMAS configuration is not saved in non-volatile memory. Therefore, you may wish to
include it in the power-up program (STARTP).
Chapter 7. Multi-Tasking
171
www.comoso.com
Following a Virtual
Master
The Gem6K allows two “Virtual Master” options for applications that require the
synchronization features of Following, but have no external master to measure.
• Internal count source.
• Internal sine wave.
Internal Count Source
The internal count source is intended to mimic the counts which might be received on an
external encoder port. Just as may be encountered with an external encoder, this count
source may speed up, slow down, stop, or count backwards. There is one count source
with a user definable and variable count frequency. The count frequency, specified in
counts per second with FVMFRQ, is a signed value, allowing the master to move forward
or backwards. The rate at which the count frequency may change is specified in counts
per second per second with the FVMACC command. This allows smooth changes in
master velocity and direction. Neither of these commands are scaled or have associated
report backs. The accumulated raw count and count rate have no report back, but may be
accessed via TPMAS and TVMAS respectively if the internal count source is specified as
master.
The associated commands are:
FVMFRQi ........................................ Where “i” is the count frequency in counts/sec
(range is 0-1,000000)
FVMACCi ........................................ Where “i” is the count accel in counts/sec2
(range is 0-9,999,999)
The count source is always enabled, counting at the signed rate specified with the
FVMFRQ command. There are no start or stop commands, no modes, distances, or limit
inputs. To stop and start the count source, specify zero or non-zero values respectively
for the FVMFRQ command. To add or subtract a “preset” number of counts (i.e., move
the master forward or backward a “preset distance”), you must calculate the time required
for that distance, (using the frequency and acceleration values), and command the
appropriate value of FVMFRQ for that duration.
Internal Sine Wave
The internal sine wave is generated using the internal count source as a frequency input.
By designating the internal sine wave as a master (e.g., FOLMAS+16), you may produce
a sinusoidally oscillating motion, with control of the phase (angle), amplitude, and center
of oscillation. There is one sine wave using the variable count frequency (FVMFRQ) to
increase or decrease the angle from which the sine is calculated. Each count of the count
frequency changes the angle by one tenth (0.1) of a degree. For example, a FVMFRQ
value of 3600 would create an angular frequency of 3600 tenths degrees per second, or 1
cycle per second. When used as a source for the sine wave, the maximum value for
FVMFRQ is 144000. This results in a maximum of 40 Hz angular frequency. Higher
frequencies are not allowed because they may be subject to aliasing.
The associated commands are:
SINANGi ........................................ Where “i” is the new angle (range is 0.0-360.0 degrees)
SINAMPi ........................................ Where “i” is the amplitude (range is 0-9,999,999 —
maximum peak-to-peak is 16384))
SINGOb .......................................... Where “b” is the binary start/stop for the master axis:
1 = restart from zero degrees
0 = stop the sine wave
The SINAMP command is included in the specification in order to allow a change in slave
amplitude without changing the center of oscillation. Changing the ratio (with FOLRN)
will also change the slave amplitude, but unless the command is given at exactly the
master zero crossing, it will also change the center of slave oscillation. The center of
oscillation may be changed by a controlled amount by using the FSHFD command. The
SINAMP command affects the sine wave immediately, without any built in ramp in
amplitude. If a gentle change is desired, a user program should be written which
172
Gem6K Series Programmer’s Guide
www.comoso.com
repeatedly issues the command with small changes in value, until the desired value is
reached.
Using SINGO with a “0” parameter abruptly stops the sine wave, without changing its
current magnitude. Using SINGO with a “1” parameter abruptly starts the sine wave, also
without changing its current magnitude. To gently pause the slave output, use an
FVMFRQ value of zero, with a moderate FVMACC value; to resume, restore the FVMFRQ
value.
The SINGO with a “1” parameter always starts at the previous angle, which may not be
the desired start of oscillation. The SINANG command will instantly change the angle
and corresponding sine of the angle. This represents an abrupt change in master position.
If the slave is still following when this occurs, there will be an abrupt change in
commanded slave position. To start the slave properly, move the slave to the desired
start position first (using MC0, D, GO), then issue SINANG, then MC1, GO1, and finally
SINGO. If SINANG is issued without any parameters, the current angle is reported, not
the most recent user SINANG command value.
Sinewave Example:
In the example below, the follower will oscillate at 1 Hz centered around zero, with a peak-topeak amplitude of 2048. Assume both the master axis and the follower axis use the same units.
Based on this assumption, we can use a following ratio of 1 to 1 and control the amplitude with
the SINAMP command. In order to provide a gentle start the oscillation is started at the bottom
of the cycle, where the velocity is zero.
D-1024
MC0
GO1
FOLMAS16
FOLRN1
FOLRD1
FOLEN1
MC1
SINAMP1024
FVMFRQ3600
FVMACC999999
SINANG270
GO1
SINGO1
Following an Integer
Variable
;
;
;
;
;
Establish desired bottom of oscillation
Put into preset move mode
Move to desired bottom location
Set follower to follow internal sine wave
Set following ratio to 1 to 1
;
;
;
;
;
;
;
;
Enable following mode
Enable continuous motion
Establish center to peak amplitude
Establish 1 Hz frequency
Reach frequency rapidly
Start angle at bottom of cycle
Lock follower to master (not started yet)
Start sine wave (and hence follower motion)
Syntax is FOLMASn8. This option allows an axis to follow the integer variable (VARI)
specified with “n”; that is, VARIn. The range for “n” is 1-8 (VARI1 – VARI8). For example,
FOLMAS48 assigns axis #1 to follow VARI4.
This option is particularly useful in conjunction with the INVARI (Map Inputs to a VARI
Variable) feature. INVARI continuously updates a specified VARI variable with the value of a
specified group of digital inputs, allowing an axis to follow a binary input pattern. Another
useful way to update the value of the VARI variable is to calculate its value in a PLCP program
(launched with the SCANP command).
The INVARI and SCANP options for updating VARI are good choices, because both are
performed every system update, thus facilitating smooth Following motion. It is also possible
to use an extra task (multi-tasking) to calculate VARI values, but the resulting updates will not
be as fast (not perfectly periodic); consequently, Follow motion will be less smooth.
Chapter 7. Multi-Tasking
173
www.comoso.com
Define the Master
and Follower
Scaling Factors;
(SCLMAS);
. . . . if required;
If you will be scaling your motion parameters (distance, velocity, acceleration/deceleration), be
aware that the only variance from non-Following scaling is that the master source (distance) is
scaled by the SCLMAS value. Virtual master sources are not scaled.
Typically, the master and follower scale factors are programmed so that master and follower units are
the same, but this is not required. Consider the scenario below as an example.
The master is a 1000-line encoder (4000 counts/rev post-quadrature) mounted to a 50 teeth/rev pulley
attached to a 10 teeth/inch conveyor belt, resulting in 80 counts/tooth (4000 counts/50 teeth = 80
counts/tooth). To program in inches, you would set up the master scaling factor with the SCLMAS800
command (80 counts/tooth * 10 teeth/inch = 800 counts/inch).
The follower axis is a servo motor with position feedback from a 1000-line encoder (4000 counts/rev).
The motor is mounted to a 4-pitch (4 revs/inch) leadscrew. Thus, to program in inches, you would set
up the follower scaling factor with the SCLD16000 command (4000 counts/rev * 4 revs/inch = 1Gem6K
counts/inch).
NOTE: Additional details on scaling and non-scaled units of measure are presented on page 67.
Define the Followerto-Master Following
Ratio (FOLRN &
FOLRD)
FOLRNF may be used to
define a final ratio for
compiled Following
profiles (see page 142).
The FOLRN and FOLRD commands establish the goal ratio between the follower and master
travel, just as the V command establishes the goal velocity for a typical non-Following move.
The FOLRN command specifies the ratio's numerator (follower travel), and the FOLRD
command specifies the ratio’s denominator (master travel). If the denominator (FOLRD) is not
specified, it is assumed to be 1.
FOLRN and FOLRD are specified with two positive numbers, but the resulting ratio applies to
moves in both directions; the actual follower direction will depend on the direction commanded
with the D command and master direction. Numeric variables (VAR) can be used with these
commands for follower and/or master parameters (e.g., FOLRN(VAR1) : FOLRD3). The
maximum value of the resulting quotient is 127 to 1.
For a preset Following move (MCØ mode), the FOLRN/FOLRD ratio represents the maximum
allowed ratio. For a continuous move (MC1 mode), it represents the final ratio r eached by the
follower axis.
Example
Define the Master
Distance; (FOLMD);
As an example, assume the follower-to-master ratio is set to 5-to-3 for an axis (FOLRN5 :
FOLRD3). The first parameter (5) is scaled by the SCLD value to give follower steps. The
second parameter (3) is scaled by the SCLMAS value to give master steps. If the SCLD setting
is 25000 and the SCLMAS setting is 4000, the follower-to-master step ratio would be 5 ∗ 25000
to 3 ∗ 4000, or 125 follower steps for every 12 master steps.
The “master distance” for moves in the Following mode (FOLEN1) is analogous to the move
time for normal time-based moves with Following disabled (FOLENØ). For time-based moves,
the time required to ramp to a new velocity (MC1 mode) or move to a new position (MCØ
mode) is determined indirectly by the acceleration (A), deceleration (AD), and velocity (V)
command values. For Following mode moves, a ramp to a new ratio (MC1 mode) or a move to
a new position (MCØ mode) takes place over a specific master distance, not over a specific
time. This distance is defined directly by the user with the FOLMD command.
In other words, the FOLMD command defines the master distance over which a preset follower
move will take place, or the master distance over which a continuous follower move will
change from its current ratio (including zero) to the commanded ratio (ratio established by
FOLRN and FOLRD).
By carefully specifying a master distance (FOLMD), a precise position relationship between
master and follower during all phases of the profile is ensured.
☞ HINT: If the follower axis is in continuous mode (MC1) and the master is starting from
rest, setting FOLMD to Ø will ensure precise tracking of the master's acceleration ramp.
If scaling is enabled (SCALE1), the FOLMD value is scaled by the SCLMAS parameter.
Examples and more information on this topic can be found below in the section titled
Follower vs. Master Move Profiles.
174
Gem6K Series Programmer’s Guide
www.comoso.com
Enable the
Following Mode;
(FOLEN1)
When an axis is configured as a follower with the FOLMAS command, it will continuously
monitor the position and motion of its master, even if the follower is at rest. This allows
subsequent motion to be related to the motion of the master via ratios (FOLRN/FOLRD) and
ramping over master distances (FOLMD). Such moves are done with Following enabled
(FOLEN1).
It is also possible, and sometimes desirable, to have the follower axis motion independent of
master axis motion, yet still “aware” of master position. For example, a move may need to
start at a specified master position, yet finish in a fixed time, independent of the master speed.
This move would be performed with Following disabled (FOLENØ).
Following may be enabled or disabled between moves, as needed, without affecting the
monitoring of the master.
If a move is performed with Following disabled, its motion profile is determined by the
acceleration, deceleration, and velocity specified with the A, AD, and V commands. Its motion
is the same as if the axis were not configured as a follower, but the axis does monitor the
master.
If a move is performed with Following enabled, its profile is determined by the specified
master distance (FOLMD) and Following ratio (FOLRN/FOLRD). The next section describes
such profiles.
Follower vs. Master Move Profiles
Before an axis begins moving in the Following Mode (FOLEN1), the program should define
how the follower will reach the commanded ratio. This is accomplished with the FOLRN and
FOLRD commands. The acceleration and deceleration of the follower can be defined in two
ways: a time-based acceleration ramp with the A and AD commands, or acceleration over a
certain master distance with the FOLMD command. Specifying an acceleration (A) for the
follower means that the acceleration ramp is time-based and there is no position relationship
between master and follower until the commanded Following ratio (defined with FOLRN and
FOLRD) is reached. Specifying a master distance for the follower's move profile (FOLMD)
ensures a precise position relationship between master and follower during all phases of the
profile. Thus, whenever the position relationship between master and follower is important, the
FOLMD method should be used. Following Status (TFSF, TFS, and FS) bits 1-4 indicate the
status of follower in motion. They mimic the meaning and organization of Axis Status (TASF
and AS) bits 1-4, except that each bit indicates the current state of the ratio, rather than the
current state of the velocity:
Bit #
Function (YES = 1; NO = Ø)
1
Follower in Ratio Move ..... A Following move is in progress
2
Ratio is Negative............... The current ratio is negative (i.e., the follower counts are counting in
the opposite direction from the master counts).
3
Follower Ratio Changing .. The follower is ramping from one ratio to another (including a ramp
to or from zero ratio).
4
Follower At Ratio .............. The follower is at constant non-zero ratio.
Chapter 7. Multi-Tasking
175
www.comoso.com
Continuous
Positioning Mode
Moves
For Following moves in the continuous positioning mode (MC1), FOLMD specifies the exact
master travel distance over which the follower ratio changes. This will be required for any
application that uses multiple ratios and continuous moves for the construction of precisely
defined multi-segment moves.
☞ HINT: If the follower is in continuous mode (MC1) and the master is starting from rest,
setting FOLMD to Ø will ensure precise tracking of the master’s acceleration ramp.
In the profile below, the first two moves each change ratio over one master inch, and the final
ramp to zero takes place over two master inches.
Ratio
3
2
1
1
Example
3
4
5
6
7
Master Travel (inches)
In the sample Gem6K code below, assume the follower has a 1000-line encoder connected to a
2-pitch leadscrew. This gives 8000 follower axis steps per inch. The master is a toothed belt
with a pulley connected to the master encoder, such that there are 800 master steps per inch.
SCALE1
SCLD8000
SCLMAS800
COMEXC1
FOLMAS1
FOLEN1
FOLMD1
FOLRD1
D+
MC1
FOLRN1
FMCNEW1
GO1
WAIT(1FS.4=B1)
FOLRN3
GOWHEN (1PMAS>=2)
GO1
FOLRN0
FOLMD2
WAIT(1AS.26=b0)
WAIT(1FS.3=b0)
GOWHEN(1PMAS>=5)
GO1
176
2
Gem6K Series Programmer’s Guide
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
;
Enable scaling
Set scaling so that follower commands are in inches
Set scaling so that master commands are in inches
Allow commands during motion
Define master to be master encoder input
Enable Following (will follow master encoder)
Follower to change ratio over 1 inch of the master travel
Set Following ratio denominator to 1 for subsequent ratios
Set direction positive
Mode set to continuous clockwise moves
Set Following ratio numerator to 1 (ratio set to 1:1)
Restart master cycle counting
Start from rest to reach velocity of master encoder
(for steppers) Wait until follower is at ratio
Set Following ratio numerator to 3 (ratio set to 3:1)
Enable motion pre-processing so that the next ramp
begins at master position 2
Follower starts ratio change to 3 to 1 at master position 2
Set Following ratio numerator to zero (ratio is 0 to 1)
Follower changes ratio over 2 inches of master travel
Wait until the previous ramp is started
(GOWHEN bit in axis status register is cleared)
Wait until the previous ramp is finished
Enable motion pre-processing so that follower motion
begins at master position 5
Wait for master to reach 5 revolutions before
follower starts ratio change to 0 (zero)
www.comoso.com
For preset positioning mode (MCØ) moves, the FOLMD parameter is the master distance over
which the entire follower move is to take place.
As an example, a follower is to move 20 inches over a master distance of 25 inches with a
maximum ratio of 1:1 (ratio set with the FOLRN1 and FOLRD1 commands). The program and
a diagram of the move profiles are provided below.
FOLMAS1
FOLMD25
;
;
;
;
;
;
;
;
;
Ratio
MC0
MA0
D20
FOLRN1
FOLRD1
GO1
Define master to be master encoder
Define follower to perform the move over 25 inches
of the master
Set positioning mode to preset
Set preset positioning mode to incremental
Set follower distance to 20 inches
Set Following ratio numerator to 1
Set Following ratio denominator to 1 (ratio is 1:1)
Perform the follower move
Master Profile
1
Slave Profile
5
10
15
20
25
Master Travel (inches)
If the master distance specified is too large for the follower distance and ratio (FOLRN and
FOLRD) commanded, the follower will never actually reach the commanded ratio, and the
move profile will look similar to that below. Here, the FOLMD is 25 inches and the follower is
commanded to move 10 inches:
Ratio
Preset Positioning
Mode Moves
Master Profile
1
Slave Profile
5
10
15
20
25
Master Travel (inches)
If the master distance is too small for the follower distance and ratio commanded, the Gem6K
will not perform the move at all. For example, if the FOLMD is 25, the ratio is 1:1, and the
follower is commanded to move 30 inches, the move will not even be attempted. The error
message “INVALID DATA” will be displayed (depending on the ERRLVL setting) and
program execution will continue.
Chapter 7. Multi-Tasking
177
www.comoso.com
Performing Phase Shifts
Following Status (TFSF, TFS and FS) bits 9-12 indicate the shift status of the follower.
Shifting is super-imposed motion, but if viewed alone, can have its own status. In other words,
bits 10-12 describe only the shifting portion of motion.
Bit #
9
Function (YES = 1; NO = Ø)
OK to Shift.......................Conditions are valid to issue shift commands (FSHFD or FSHFC).
10
Shifting now ....................A shift move is in progress.
11
Shift is Continuous ..........An FSHFC-based shift move is in progress.
12
Shift Dir is Neg ................The direction of the shift move in progress is negative.
When a follower is following a master continuously, it may be necessary to adjust, or shift, the
Following phase (follower’s position with respect to the master) independent of motion due to
ratio moves. The FSHFC and FSHFD commands allow time-based follower moves to be
superimposed upon ratio Following moves. Because phase shifts are time-based, they are
independent of master motion; in fact, the master may be at rest and a shift may still be
performed.
Use the FSHFD command to perform a preset shift move with a specific change in follower
phase. The FSHFD distance value will be scaled by SCLD if scaling is enabled (SCALE1).
Use the FSHFC command to superimpose a continuous shift move in the positive (FSHFC1)
or negative (FSHFC2) direction. The FSHFC parameters stop (Ø) and kill (3) can be used to
halt a continuous FSHFC move or a preset FSHFD move without affect the ratio motion.
The most recently defined velocity and acceleration (i.e., the V and A values) for the follower
will determine the basis for the superimposed shift move profile for both FSHFC and FSHFD
moves. The commanded velocity of the FSHFC or FSHFD move will be added to the current
velocity at which the follower is performing the Following move . For example, assume a
follower is traveling at 1 rps in the positive direction as a result of following a master. If a
FSHFC move is commanded in the positive direction at 2 rps, the follower's actual velocity
(after acceleration) will be 3 rps.
For servos, shifting may be performed whenever Following is enabled (FOLEN1). For steppers,
this may only be done while Following is enabled and the follower is either not in a move, or is
in continuous positioning mode (MC1) and moving at constant ratio. For both products, TFS/FS
bit 9 indicates when a shift is allowed.
The current follower position (TPSLV value) and the net follower shift accumulated since the
most recent FOLEN1 command (TPSHF value) may be read into numeric variables (VAR)
using the PSLV and PSHF commands, respectively (e.g., VAR6=1PSLV). They may also be
used for subsequent decision making (e.g., IF(1PSHF<6), GOWHEN(1PSLV>VAR2), etc.).
The TPSHF and PSHF values are set to zero each time the Following mode is enabled
(FOLEN1), even if the follower is already in Following mode. This provides a way of
clearing these values for programming convenience.
Note that the distance traveled during the time-based deceleration due to stop, kill, or limits is
included in the PSHF value. By comparing “before and after” values of PSHF, a Gem6K
program may calculate how much shift was required to perform visual- or sensor-based
alignment of a master/follower phase relationship.
178
Gem6K Series Programmer’s Guide
www.comoso.com
Phase Shift
Examples
FSHFC Example
An FSHFC or FSHFD move may be needed to adjust the follower position on the fly because of
a load condition which changes during the continuous Following move. Below are
programming examples to demonstrate both shift methods.
An operator is visually inspecting the follower’s continuous Following motion with respect to
the master. If he notices that the master and follower are out of synchronization, it may be
desirable to have an interrupt programmed (e.g., activated by pressing a push-button switch)
that will allow the operator to move the follower at a superimposed correction speed until the
operator chooses to have the follower start tracking the master again (by releasing the pushbutton). The programming example below illustrates this.
Assume all scale factors and set-up parameters have been entered for the master and follower.
In this example, the follower is continually following the master at a 1:1 ratio. If the operator
notices some mis-alignment between master and follower, he can press 1 of 2 pushbuttons
(connected to onboard trigger inputs #1 and #2) to shift the follower in the positive or
negative direction until the button is released. After the adjustment, the program continues on
as before.
DEL SHIFT
DEF SHIFT
COMEXS1
COMEXC1
FOLMAS1
FOLRN1
FOLRD1
;
;
;
;
;
;
;
;
FOLEN1
;
A25
;
AD18
;
V5
;
D+
;
MC1
;
GO1
;
VARB1=b10
;
VARB2=b01
;
$TESTIN
;
IF(IN=VARB1)
;
JUMP SHIFTP
;
;
NIF
;
IF(IN=VARB2)
;
JUMP SHIFTN
;
;
NIF
;
JUMP TESTIN
;
$SHIFTP
;
;
FSHFC1
;
WAIT(IN.1=B0)
;
FSHFC0
;
WAIT(1FS.10=B0) ;
JUMP TESTIN
;
$SHIFTN
;
;
FSHFC2
;
;
WAIT(IN.2=B0)
;
FSHFC0
;
WAIT(1FS.10=B0) ;
JUMP TESTIN
;
END
;
Delete program before defining
Begin definition of program called SHIFT
Continue command execution after stop
Continue command execution during motion
Master encoder is the master
Set follower-to-master Following ratio numerator to 1
Set follower-to-master Following ratio denominator to 1
(ratio set to 1:1)
Enable Following mode
Set acceleration
Set deceleration
Set velocity
Set direction to positive
Select continuous positioning mode
Start following master continuously
Define onboard input pattern #1 and assign to VARB
Define onboard input pattern #2 and assign to VARB
Define label called TESTIN
IF statement (if input #1 is activated, do the jump)
Jump to shift follower in the positive direction
when pattern 1 active
End of IF statement
IF statement (if input #2 is activated, do the jump)
Jump to shift follower in the negative direction
when pattern 2 active
End of IF statement
Return to main program loop
Define label called SHIFTP (subroutine to shift in
the positive direction)
Start continuous follower shift in positive direction
Continue shift until input bit #1 is deactivated
Stop shift move
(steppers only) Wait until the shift is completed
Return to main program loop
Define label called SHIFTN (subroutine to shift
in the negative direction)
Start continuous follower shift move in the
negative direction
Continue shift until bit #2 is deactivated
Stop shift move
(steppers only) Wait until the shift is completed
Return to main program loop
End definition of program called SHIFT
Chapter 7. Multi-Tasking
179
www.comoso.com
FSHFD Example
In this example, the follower follows a master that moves in a continuous cycle. Once each
cycle, the master and follower both pick parts. The master’s part is detected by a sensor
connected to trigger 1B, and the follower’s part is detected by a sensor connected to trigger 1A.
After both parts are detected, they must be aligned. The sensors are mounted 2 inches apart
from each other, so that proper alignment would result in 2 inches of follower travel between
detection of the master's part and detection of the follower’s part.
The follower position is sampled when each of the sensors activates. The difference between
the follower positions is compared to the required 2 inches. If the measured difference is
greater than or less than 2 inches, then a shift move to correct the alignment is made. At that
point, the follower will then start tracking the master again. The follower is continually
following the master at a 1:1 ratio.
DEL ALIGN
DEF ALIGN
COMEXC1
FOLMAS1
FOLRN1
FOLRD1
; Delete program before defining
; Begin definition of program called ALIGN
; Allow continuous command execution during motion
; The master encoder input is the master
; Set follower-to-master ratio numerator to 1
; Set follower-to-master ratio denominator to 1
; (ratio set to 1:1)
FOLEN1
; Enable Following mode
MC1
; Enable continuous positioning mode
D+
; Set direction to positive
GO1
; Start Following master continually
INFNC1-H
; Enable trigger input 1A to latch position of follower
; when the follower's part is detected
INFNC2-H
; Enable trigger input 1B to latch position of follower
; when the master's part is detected
$SYNCLP
; Main loop where synchronizing moves occur
WAIT(TRIG.1=b1 AND TRIG.2=b1)
; Wait for both follower and master inputs to occur
VAR10=1PCCA
; Load VAR10 with the follower commanded position due
; to follower input activation
VAR11=1PCCB
; Load VAR11 with the follower commanded position due
; to master input activation
VAR12=VAR10-VAR11 ; Load VAR12 with the offset distance
VAR13=VAR12-2
; Calculate the required shift
FSHFD(VAR13)
; Perform synchronization move of distance in VAR13
JUMP SYNCLP
; Return (jump) to main program loop
END
; End of program
Geared Advance Following
The FGADV command provides the ability to super-impose an advance or retard on Following
motion. This is the same ability provided by the FSHFD command (see Performing Phase
Shifts above), except that the super-imposed motion is also geared to master motion. The
FGADV command has the positive or negative “advance” distance as a parameter, but it
initiates motion instead of simply setting up the distance. The shape of the super-imposed
profile is determined by the FOLMD, FOLRN, and FOLRD commands (just as a normal preset
Following move).
The FGADV command profile may be delayed with the GOWHEN command.
A FGADV move may be performed only while the conditions below exist (Following status bit
#23, reported with the FS, TFS, and TFSF commands, indicates that it is “OK to do FGADV
move”):
• Master is specified with a FOLMAS command
• Following is enabled with the FOLEN command
• The follower is either not moving, or moving at constant ratio in continuous mode
(MC1)
180
Gem6K Series Programmer’s Guide
www.comoso.com
A FGADV move may not be performed:
• During a preset (MC0) move
• In a compiled profile or program
Following Status (FS, TFS, and TFSF) bit #24 reports if a “FGADV move is underway”.
Example
COMEXC1
FOLRN25
FOLRD10
FOLMD1000
MC1
D+
FOLEN1
GO
FOLMD500
FOLRN13
WAIT(FS.23=B1)
;
;
;
;
;
;
;
;
;
;
;
;
FGAVD400
;
;
WAIT (FS.23=B1) ;
;
FGADV-400
;
;
All command processing during motion
Set numerator of follower-to-master Following ratio
Set denominator of follower-to-master Following ratio
Set master distance to 1000 units
Enable continuous positioning mode
Set direction to positive
Enable Following
Ramp up to a 2.5:1 ratio over 1000 master distance units
Set master distance to 500 units
Superimposed ratio will be 1.3 (added to 2.5 = 3.8 total)
Wait for OK to do geared advance
(in this case, ramp is complete)
Advance the follower 400 counts over a distance
of 500 master counts
Wait for OK to do geared advance (in this case,
FGADV400 super-imposed profile is complete)
Retard the follower 400 counts over a distance of
500 master counts (2.5 - 1.3 = 1.2 net ratio)
Summary of Ratio Following Commands
ANIMAS ............................ Assigns an analog input to be used as a master in a FOLMAS assignment
(requires a ANI SIM located on an expansion I/O brick)
FGADV .............................. Defines the geared advance distance
FOLEN .............................. Enables or disables Following mode
FOLMAS ............................ Defines masters
FOLMD .............................. Defines the master distance over which follower acceleration or moves are
to take place
FOLRN and FOLRD............. Establishes the maximum follower-to-master ratio for a preset move or the
final ratio for a continuous move (FOLRN for the numerator and FOLRD for
the denominator)
FSHFD .............................. Initiates preset advance or retard (shift) of follower position during
continuous Following moves
FSHFC .............................. Initiates continuous advance or retard (shift) of follower position (or kills or
stops the shift portion of motion) during continuous Following moves
FVMACC ............................ Establishes the rate at which the virtual master count frequency (FVMFRQ)
may change.
FVMFRQ ............................ Defines the frequency of the virtual master count.
SCLD ................................ Sets the follower distance scale factor
SCLMAS ............................ Sets the master distance scale factor
SINAMP ............................ Defines the amplitude of the internal sine wave
SINANG ............................ Defines the phase angle of the internal sine wave
SINGO .............................. Initiates the internal sine wave
TPSHF or [ PSHF ]........... Transfers or assigns the net position shift since constant ratio
TPSLV or [ PSLV ]........... Transfers or assigns the current follower position
TVMAS or [ VMAS ]........... Transfers or assigns the velocity of the master
Chapter 7. Multi-Tasking
181
www.comoso.com
Master Cycle Concept
Ratio Following can also address applications that require precise programming
synchronization between moves and I/O control based on master positions or external
conditions. The concept of the master cycle greatly simplifies the required synchronization.
A master cycle is simply an amount of master travel over which one or more related follower
axis events take place. The distance traveled by the master in a master cycle is called the
master cycle length. A master cycle position is the master position relative to the start of the
current master cycle. The value of master cycle position increases as positive-direction
master cycle counts are received, until it reaches the value specified for master cycle length.
At that point, the master cycle position becomes zero, and the master cycle number is
incremented by one—this condition is called rollover.
The master cycle concept is analogous to minutes and hours on a clock. If the master cycle is
considered an hour, then the master cycle length is 60 minutes. The number of minutes past
the hour is the master cycle position, and current hour is the master cycle number. In this
analogy, the master cycle position decrements from 59 to zero as the hour increases by one.
By specifying a master cycle length, periodic actions may be programmed in a loop or with
subroutines which refer to cycle positions, even though the master may be running
continuously. To accommodate applications where the feed of the product is random, the start
of the master cycle may be defined with trigger inputs. Two types of waits are also
programmable to allow suspension of program operation or follower moves based on master
positions or external conditions.
Master Cycle Commands
Following Status (TFSF, TFS and FS) bits 13-16 indicate the status of master cycle counting.
If a following application is taking advantage of master cycle counting, these bits provide a
quick summary of some important master cycle information:
Bit #
Master Cycle Length
(FMCLEN);
Function (YES = 1; NO = Ø)
13
Master Cyc Trig Pend .....A master cycle restart pending the occurrence of the specified trigger.
14
Mas Cyc Len Given.........A non-zero master cycle length has been specified with FMCLEN.
15
Master Cyc Pos Neg .......The current master cycle position (PMAS) is negative. This could be
by caused by a negative initial master cycle position (FMCP), or if the
master is moving in the negative direction.
16
Master Cyc Num > 0 .......The master position (PMAS) has exceeded the master cycle length
(FMCLEN) at least once, causing the master cycle number (NMCY) to
increment.
The FMCLEN command is used to define the length of the master cycle. The value entered
with this command is scaled by the SCLMAS parameter to allow specification of the master
cycle length in user units. This parameter must be defined before those commands which wait
for periodically repeating master positions are executed.
The default value of FMCLEN is zero, which means the master cycle length is practically
infinite (i.e., 4,294,967,246 steps, after scaling). If a value of zero is chosen, the master cycle
position will keep increasing until this very high value is exceeded or a new cycle is defined
with the FMCNEW command (or triggered after a TRGFNcx1 command) described below. If a
non-zero value for FMCLEN is chosen, the internally maintained master cycle position will
keep increasing until it reaches the value of FMCLEN. At this point, it immediately rolls over
to zero and continues to count.
The master cycle length may be changed with the FMCLEN command even after a master cycle
has been started. The new master cycle length takes affect as soon as it is issued. If the new
master cycle length is greater than the current master cycle position, the cycle position will not
change, but will rollover when the new master cycle length is reached. If the new master
182
Gem6K Series Programmer’s Guide
www.comoso.com
cycle length is less than the current master cycle position, the new master cycle position
becomes equal to the old cycle position minus one or more multiples of the new cycle length.
Example
Code
Restart Master Cycle
Counting (FMCNEW or
TRGFNcx1xxxxxx);
FMCLEN23
; Set master cycle length:
; (axis 1: 23 units
Once the length of the master cycle has been specified with the FMCLEN command, master
cycle counting may be restarted immediately with the FMCNEW command, or based on
activating a trigger input as specified with the TRGFNcx1 command. The new master cycle
count is started at an initial position specified with the FMCP command (see below).
When the TRGFNcx1 command is used, the restart of master cycle counting is pending
activation of the specified trigger. If an FMCNEW command is issued while waiting for the
specified trigger to activate, counting is restarted immediately with the FMCNEW command,
and the TRGFNcx1 command is canceled.
When using TRGFNcx1
•
•
Before the TRGFN command can be used, you must first assign the trigger interrupt function
to the specified trigger input with the INFNCi-H command, where “i” is the input number of
the trigger input desired for the function (input bit assignments vary by product).
Because the Gem6K program will not wait for the trigger to occur before continuing on with
normal program execution, a WAIT or GOWHEN condition based on PMAS will not evaluate
true if the restart of master cycle counting is pending the activation of a trigger. To halt
program operation, the WAIT command can be used.
A new master cycle will restart automatically when the total master cycle length (FMCLEN value)
is reached. This is useful in continuous feed applications.
Example
Code
FMCNEW1
INFNC2-H
1TRGFNBx1
Initial Master Cycle
Position (FMCP);
;
;
;
;
Restart new master cycle counting
Assign input #2 (TRG-1B) the trigger interrupt
function (prerequisite to using the TRGFN features)
When trigger input 2 (TRG-1B) goes active,
The FMCP command allows you to assign for the first cycle only, an initial master cycle
position to be a value other than zero. When master cycle counting is restarted with the
FMCNEW command or with the trigger specified in the TRGFNcx1 command, the master cycle
position takes the initial value previously specified with the FMCP command. The value for
FMCP is scaled by SCLMAS if scaling is enabled (SCALE1)
FMCP was designed to accommodate situations in which the trigger that restarts master cycle
counting occurs either before the desired cycle start, or somewhere in the middle of what is to
be the first cycle. In the former case, the FMCP value must be negative. The master cycle
position is initialized with that value, and will increase right through zero until it reaches the
master cycle length (FMCLEN). At that point, it will roll over to zero as usual.
The continuous cut-to-length example below illustrates the use of a negative FMCP (a trigger
that senses the motion of the master is physically offset from the master position at which
some action must take place). If it is desired that the first cycle is defined as already partially
complete when master cycle counting is restarted, the FMCP value must be greater than zero,
but less than the master cycle length.
To give a value for FMCP which is greater than master cycle length is meaningless since
master cycle positions are always less than the master cycle length. The Gem6K responds to
this case as soon as a new master cycle counting begins by using zero instead of the initial
value specified with FMCP.
Chapter 7. Multi-Tasking
183
www.comoso.com
Transfer and
Assignment/
Comparison of Master
Cycle Position and
Number;
The current master cycle position and the current master cycle number may be displayed with
the TPMAS and TNMCY commands, respectively. These values may also be read into numeric
variables (VAR) at any time using the PMAS and NMCY commands (e.g., VAR6=NMCY). If
position capture is used, the master cycle position and be captured, and the value is available
with the TPCMS and PCMS commands.
Very often, the master cycle number will be directly related to the quantity of product produced
in a manufacturing run, and the master cycle position can be used to determine what portion of
a current cycle is complete.
The master cycle number is sampled once per position sampling period (see note, left). If the
master cycle length (FMCLEN) divided by the master's velocity (VMAS) is less than the
position sampling period (2 ms), then the sample (TNMCY or NMCY value) may not be
accurate.
Details on using PMAS in conditional expressions is provided below in Using Conditional
Statements with PMAS.
Using Conditional
Statements with
Master Cycle Position
(PMAS);
The current master cycle position (PMAS) value may be used in comparison expressions, just
like other position variables such as PC, PE, and FB. PMAS is a special case, however, because
its value rolls over to zero when the master cycle length (FMCLEN) is met or exceeded. This
means that PMAS values greater than or equal to the master cycle length will never be reported
with the TPMAS command, or with expressions such as (VAR1=1PMAS).
The other fact that makes PMAS special is that master cycle counting may be restarted after
the command containing the PMAS expression has been executed. Either the FMCNEW
command or the TRGFNcx1 command may be used to restart counting, each with a different
effect on the evaluation of PMAS.
The treatment of PMAS in comparison expressions depends on the command using the
expression, as described below. WAIT and GOWHEN are treated as special cases.
IF, UNTIL, and
WHILE
These commands evaluate the current value of PMAS in the same way that TPMAS does (i.e.,
PMAS values will never be greater than or equal to the master cycle length). With these
commands, avoid comparing PMAS to be greater than or equal to variables or constants which
are nearly equal to the master cycle length, because rollover may occur before a PMAS sample
is read which makes the comparison true. If such a comparison is necessary, it should be
combined (using OR) with a comparison for master cycle number (NMCY) being greater than
the current master cycle number.
Also, master cycle counting restart may be pending activation of a trigger, but this will not
affect the evaluation of PMAS for IF, WAIT, and WHILE. It is simply evaluated based on
counting currently underway.
WAIT and GOWHEN
These commands evaluate the current value of PMAS differently than TPMAS does, in such a
way that it is possible to compare PMAS to variables or constants which are greater than or
equal to the master cycle length and still have the comparison be reliably detected.
Effectively, PMAS is evaluated as if the master cycle length were suddenly set to its maximum
value (232) at the time the WAIT or GOWHEN command is encountered. It eliminates the need to
OR the PMAS comparison with a comparison for master cycle number (NMCY) being greater than
the current master cycle number. Such multiple expressions are not allowed in the GOWHEN
command, so this alternative evaluation of PMAS offers the required flexibility.
This method of evaluation of PMAS allows commands which sequence follower axis events
through a master cycle to be placed in a loop. The WAIT or GOWHEN command at the top of
the loop can execute, even though the actual master travel has not finished the previous cycle.
If it is desired to WAIT or GOWHEN for a master cycle position of the next master cycle, the
variable or constant specified in the command should be calculated by adding one master
cycle length to the desired master cycle position.
184
Gem6K Series Programmer’s Guide
www.comoso.com
Finally, master cycle counting restart may be pending activation of a trigger (TRGFNcx1),
and this will suspend the evaluation of PMAS for these commands. PMAS is not sampled, and
the comparison evaluates as false. During this time, if the pending status of master cycle
counting restart is aborted with FMCNEWØ, the GOWHEN condition is also cleared, and any
motion profile of any axis waiting on that PMAS comparison will be canceled. Otherwise,
when master cycle counting is restarted by a trigger, evaluation takes place as described
above. This allows GOWHEN to include waiting on a trigger without explicitly including it in
the GOWHEN expression.
Synchronizing
Following Moves with
Master Positions
A final special case allows perfect synchronization between the start of a Following motion
profile of a follower axis and a specified position of its master. If a GOWHEN(1PMAS >= x)
expression is used to synchronize a follower with its own master, with the operator specifically
“>=”, a special synchronization occurs. Although it may be impossible for the Gem6K product
to sample the exact master position specified, the Following motion profile is calculated from
master travel based on that position. This allows for the construction of profiles in which the
synchronization of master and follower positions is well defined and precisely maintained.
This feature requires positive travel of the master, which can be achieved with the appropriate
sign for the FOLMAS specification.
Summary of Master Cycle and Wait Commands
FMCLEN................................ Defines the length of the master cycle
FMCNEW................................ Immediately restart master cycle counting
FMCP .................................... Defines the initial position of a new master cycle
GOWHEN................................ GOWHEN suspends execution of the next move on the specified axis until
the specified conditional statement (based on T, IN, LIM, FB, NMCY, PC,
PE, PMAS, PSLV, or PSHF) is true
TNMCY or [ NMCY ].............. Transfers or assigns the current master cycle number
TPCMS or [ PCMS ]............... Transfers or assigns the captured master cycle position
TPMAS or [ PMAS ].............. Transfers or assigns the current master cycle position
TRGFN .................................. aTRGFNc1x initiates a GOWHEN, suspending execution of the next
follower move on axis (a) until the specified trigger input (c) goes active.
aTRGFNcx1 causes master cycle counting to restart when the specified
trigger input (c) goes active.
WAIT .................................... WAIT suspends program execution until the specified conditional
statement (based on PMAS, FS, NMCY, PCMS, PSHF, PSLV, or VMAS) is
true;
WAIT(SS.i=b1) suspends program execution until a trigger input is
activated. The “i” is the programmable input bit number corresponding
to the trigger input. (Input bit assignments vary by product; refer to the
Programmable I/O Bit Patterns table on page 91 to determine the
correct bit pattern for your product.)
AS and TAS bit #26 ............... AS and TAS (and TASF) bit #26 is set when there is a profile suspended
pending GOWHEN condition, initiated either by a GOWHEN command or a
TRGFNc1 command; this bit is cleared when the GOWHEN condition is
true or when a stop or kill command is issued.
ER and TER bit #14 ............... ER, TER, and TERF bit #14 is set if the GOWHEN condition is already true
when the GO, GOL, FGADV, FSHFC, or FSHFD command is given (ERROR
bit #14 must first be enabled to check for this condition)
NOTE
The continuous cut-to-length application example below illustrates the use of the master
cycle concept and the commands above.
Chapter 7. Multi-Tasking
185
www.comoso.com
Technical Considerations for Following
In the introduction to Following (see page 168), the algorithm for Gem6K Following was
briefly discussed. Here we will address some of the more technical aspects of Following:
Keep in mind that
in all cases, the
follower position is
calculated from a
sampled master
position.
•
•
•
•
•
•
•
•
•
Performance
Master Position Prediction
Master Position Filtering
Following error
Maximum acceleration and velocity (stepper axes only)
Factors affecting Following accuracy
Preset vs. Continuous Following moves
Master and follower axis distance calculations
Using other features with Following
Performance Considerations
When a follower axis is following a master, the Gem6K does not simply measure the master
velocity to derive follower axis velocity. Instead, the Gem6K samples the master position
(position sampling period = 2 ms) and calculates the corresponding follower axis position
command. This is true even if the follower axis is in the process of changing ratios. A follower
axis is not simply following velocity, but rather position. With this algorithm, the master and
follower position or phase relationship is maintained indefinitely, without any drift over time due
to velocity measurement errors.
The Gem6K also measures master velocity by measuring the change in master position over a
number of sample periods. The present master velocity and position may be used to calculate
the next commanded follower position, so the follower has no velocity-dependent phase
delay. This concept is known as Master Position Prediction and may be enabled or disabled
as needed with the FPPEN command.
The Gem6K's default Following algorithm should work well for most applications; however,
you can change the Following algorithm to meet application-specific needs. For instance,
suppose that the speed of the master is very slow, or has some vibration. For a case like this,
the Gem6K allows you to filter the master position signal to generate a smooth follower
position command. This is known as Master Position Filtering and is programmed with the
FFILT command.
186
Gem6K Series Programmer’s Guide
www.comoso.com
Master Position Prediction
Master Position Prediction is a technique used to compensate for the fact a follower's position
command cannot be calculated and implemented infinitely fast.
The master position prediction mode is enabled by default (FPPEN1) in the Following
algorithm, but can be turned off as desired with the FPPENØ command.
The Gem6K measures master position once per position sampling period (2 ms), and
calculates a corresponding follower position command. This calculation and achieving the
subsequent follower commanded position requires 2 sample periods (4 ms).
If master position prediction mode is disabled (FPPENØ), waiting 2 sample periods results in
a follower position lag. That is, by the time the follower reaches the position that corresponds
to the sampled master position, 2 sample periods have gone by, and the master may be at a
new position. Measured in time, the lag is 2 sample periods. Measured in position, the lag is
2 sample periods ∗ current follower velocity.
For example, suppose the follower is traveling at a speed of 25000 counts per second. If
master position prediction mode is disabled (FPPENØ), the follower will lag the master by
100 counts (25000 counts/sec ∗ 4 ms = 100 counts).
By measuring the change in master position over sequential sample periods, the master's
present velocity is calculated. The present master velocity and position are used to predict
future master position. If master position prediction mode is enabled (FPPEN1, the predicted
future master position is used to determine the follower's position command. In this case the
follower has no velocity-dependent phase delay. The follower's velocity for a given sample
will always be the velocity required to move from its current position to the next calculated
position command.
If the master motion is fairly smooth and velocity is not very slow, the measurement of its recent
velocity will be very accurate, and a good way of predicting future position. But the master
motion may be rough, or the measurements may be inaccurate if there is no filtering (see Master
Position Filtering below). In this case, the predicted master position and the corresponding
follower position command will have some error, which may vary in sign and magnitude from
one sample to the next. This random variation in follower position command error results in
rough motion. The problem is particularly pronounced if there is vibration on the master.
It may be desirable to disable the master position prediction mode (FPPENØ) when maximum
follower smoothness is important and minor phase delays can be accommodated.
If master filtering is enabled (FFILT_Ø), then the prediction algorithm would be used on the
filtered master position, resulting in a smoother follower position command. However, due to
the delay introduced by the filtering, the prediction algorithm would not compensate for the
total delay in the follower's tracking command. (See also Master Position Filtering below.)
Following Status (TFSF, TFS, and FS) bit 17 indicates the status of where or not the master
position prediction mode is enabled.
Master Position Filtering
The follower axis' position command is calculated at each position sample period (2 ms). This
calculation is a function of the master position and the master velocity estimated from the
change in master position over 2 position sample periods.
The Master Position Filter feature allows you to apply a low-pass filter to the measurement of
master position. Master position filtering is used in these situations:
• Measurement of master position is contaminated by either electrical noise (when analog
input is the master) or mechanical vibration.
• Measurement noise is minimal, but the motion that occurs on the master input is
oscillatory. In this case, using the filter can prevent the oscillatory signal from
propagating into the follower axis (i.e., ensuring smoother motion on the follower axis).
Chapter 7. Multi-Tasking
187
www.comoso.com
The bandwidth of the low-pass filter is controlled with the FFILT command:
FFILT Setting
Low pass Filter Bandwidth
Ø
infinite (no filtering) – default setting
1
120 Hz
2
80 Hz
3
50 Hz
4
20 Hz
When considering whether or how much master position filtering to use, consider the
application requirement itself. The application requirements related to filtering can be
categorized into these three types:
Type I:
If an application requires smooth motion but also high follower tracking accuracy,
then a heavy filtering should not be used. It should not be used because it may
introduce too much velocity phase lag, although the motion may be smooth. In
other words, the master axis in the first place should produce very smooth motion
and low sensor measurement noise such that a higher level of master filtering is
not needed.
Type II:
If follower axis velocity tracking error is not critical but smooth follower axis
motion is desired, then you can use a higher level of master filtering to deal with
sensor noise or master vibration problems.
Type III:
If it is determined that under certain dynamic conditions the master position's
oscillatory measurement is purely caused by its vibration motion (noise is
insignificant), and it is necessary for the follower to follow such motion, then the
filter command should not be used or only use the highest bandwidth (FFILT1).
Following Status (TFSF, TFS, and FS) bit 18 indicates the status of master position filtering.
Following Error
As soon as an axis becomes configured as a follower, the follower's position command is
continuously updated and maintained. At each update, the position command is calculated
from the current master position and velocity, and the current ratio or velocity of the follower.
Whenever the commanded position is not equal to the actual follower position, a Following
error exists. This error, if any, may be positive or negative, depending on both the reason for
the error and the direction of follower travel. Following error is defined as the difference
between the commanded position and the actual position.
Following Error = Commanded position - Actual position
If the follower is traveling in the positive direction and the actual position lags the
commanded position, the error will be positive. If the follower is traveling in the negative
direction and the actual position lags the commanded position, the error will be negative. This
error is always monitored, and may be read into a numeric variable (VAR) at any time using
the PER command. The error value in follower steps is scaled by SCLD for the axis. This
value may be used for subsequent decision making, or simply storing the error corresponding
to some other event.
188
Gem6K Series Programmer’s Guide
www.comoso.com
Maximum Velocity and Acceleration
(Stepper Axes Only)
The follower's attempt to faithfully follow the master may command velocities and
accelerations that the follower axis is physically not able to complete. Therefore, the FMAXV
and FMAXA commands are provided to set the maximum velocity and acceleration at which
the follower will be allowed to move.
If the follower is commanded to move at rates beyond the defined maximums, the follower
will begin falling behind it's commanded position. If this happens, a correction velocity will
be applied to correct the position error as soon as the commanded velocity and acceleration
fall within the limitation of FMAXV and FMAXA.
The FMAXA and FMAXV commands should be used only to protect against worst case
conditions, and should be avoided altogether if they are not needed. If an axis is not able to
follow its profile because of limitations imposed by these commands, some correction motion
will occur. If the maximum acceleration (FMAXA value) is set very low, some oscillation
about the commanded position may occur because the follower is not allowed to decelerate
fast enough to prevent overshoot.
Factors Affecting Following Accuracy
There are additional accuracy requirements of Following applications beyond those of
standard positioning. The follower axis must maintain positioning accuracy while in motion,
not just at the end of moves, because it is trying to stay synchronized with the master.
Assuming parameters such as master and follower scaling and ratios have been specified
correctly, the overall positioning accuracy for an application depends on several factors:
•
•
•
•
•
•
•
•
•
Resolution of the master
Resolution of the follower axis
Position sampling accuracy
Accuracy of the follower axis motor and drive
Accuracy of load mechanics
Master position prediction
Master velocity relative to master position prediction & master position filtering
Tuning (servo axes only)
Repeatability of the trigger inputs and sensors
Just as with a mechanical arrangement, the accuracy errors can build up with every link from
the beginning to the end. The overall worst case accuracy error will be the sum of all the
sources of error listed below. The errors fall into two broad categories, namely, master
measurement errors and follower errors. These both ultimately affect follower accuracy,
because the commanded follower position is based on the measured master position.
It is important to understand how master measurement errors result in follower position errors.
In many applications, master and follower units will be the same (e.g., inches, millimeters,
degrees). These applications will require linear speeds or surface speeds to be matched (i.e., a
1:1 ratio). For example, suppose that in a rotary knife application, there were 500 master
steps per inch of material, so an error in master measurement of one encoder step would result
in 0.002 inches of follower position error.
If the master and follower units are not the same, or the ratio is not 1:1, the master error times
the ratio of the application gives the follower error. An example would be a rotary master and
a linear follower. For instance, suppose one revolution of a wheel gives 4000 master counts,
and results in 10 inches of travel on the follower. The ratio is then 10 inches/revolution. The
follower error which results from one step of master measurement error is (1/4000) ∗ 10
inches/revolution = 0.0025 inches.
Chapter 7. Multi-Tasking
189
www.comoso.com
Resolution of the
Master;
The best case master measurement precision is the inverse of the number of master steps per
user's master unit. For example, if there are 100 master steps/inch, then the master
measurement precision is 0.01 inches. Even if all other sources of error are eliminated,
follower accuracy will only be that which corresponds to 1 step of the master (e.g., 0.01 inches
in the previous example).
Resolution of the
Follower;
The best case follower axis precision is the inverse of the number of follower steps per user's
position unit. For example, if there are 1000 follower steps/inch, then the follower resolution is
0.001 inches. Even if all other sources of error are eliminated, follower positioning accuracy
will only be that which corresponds to 1 step of the follower. This must be at least as great as
the precision required by the application.
Position Sampling
Accuracy;
The position sampling rate for the Gem6K depends on whether it is a servo or a stepper. The
sample period for is 2 ms.
The repeatability of the sampling rate, from one sample to the next, may vary by as much as
100 µs. This affect may be eliminated by using non-zero master position filter (FFILT)
command values. Otherwise, measurement of master position may be off by as much as (20 to
100 microseconds ∗ master speed). This may appear to be a significant value at high master
speeds, but it should be noted that this error changes in value (and usually sign) every sample
period. It is effectively like a noise of 200-600 Hz; if the mechanical frequency response of the
motor and load is much less than this frequency, the load cannot respond to this error.
Accuracy of the
Follower Motor and
Drive;
The precision also depends on how accurately the drive follows its commanded position while
moving. Even if master measurement were perfect, if the drive accuracy is poor, the precision
will be poor.
In the case of stepper drives, this amounts to the specified motor/drive accuracy.
In the case of servo drives, the better the drive is tuned for smoothness and zero Following
error, the better the precision of the positioning. Often, this really only matters for a specific
portion of the profile, so the drive should be tuned for zero Following error at that portion.
Accuracy of the
Load Mechanics
The accuracy (not repeatability) of the load mechanics must be added to the overall build up of
accuracy error. This includes backlash for applications which involve motion in both
directions.
Master Position
Prediction;
The master position prediction mode may be enabled or disabled with the FPPEN command,
but each state contributes a different error.
Disabled (FPPENØ): The follower position command is based on a master position that is 2
sample periods (4 ms) old. This means that master measurement error due to
disabling the position prediction mode will be (2 sample periods ∗ master speed).
Enabled (FPPEN1): If the position prediction mode is enabled (default setting), its accuracy is
also affected by position sampling accuracy, master speed, and master position
filtering. The error due to enabling the position prediction mode is about twice that
due to sampling accuracy (i.e., 40 to 200 microseconds ∗ master speed). As with the
error due to position sampling accuracy, the error due to the position prediction mode
being enabled is like a noise on the order of 200-600 Hz, which is not noticed by
large loads.
190
Gem6K Series Programmer’s Guide
www.comoso.com
Master Velocity
Relative to Master
Position Prediction;
Variation in Master Velocity: Although increasing master position filtering (increasing the
FFILT command value) eliminates the error due to sampling accuracy, it increases the error
due to variations in master speed when the master position prediction mode is enabled
(FPPEN1).
Most applications maintain a constant master speed, or change very slowly, so this effect is
minimal. But if the master is changing rapidly, there may be a significant master speed
measurement error. Because predicted master positions are in part based on master speed
measurement, the can result in an error in master position prediction mode (FPPEN1). This
effect will always be smaller than that due to the master position prediction mode being
disabled (FPPENØ).
Tuning;
(Servo Axes Only)
Repeatability of the
Trigger Inputs and
Sensors;
A servo system’s tuning has a direct impact on how well the follower axis can track the master
input. Overshoot, lag, oscillation, etc., can be devastating to Following performance. The best
tool to use for tuning the Gem6K series controller is Motion Planner’s Gemini Servo Tuner
utility.
Some applications may use the trigger inputs for functions like registration moves, GOWHENs,
or new cycles. For these applications, the repeatability of the trigger inputs and sensors add to
the overall position error.
Refer to page 99 for accuracy specifications on the trigger input position capture function.
Refer to your sensor manufacturer’s documentation for the sensor repeatability. In the Gem6K
controller, the position capture from the trigger inputs have approximately 100 µs
repeatability, and the sensor repeatability (SR) should be determined, too. Velocity ∗ time =
distance, so the error due to repeatability is (SR + 0.0001 seconds) ∗ speed = error. If the
sensor repeatability is given in terms of distance, that value can be added directly.
Preset vs. Continuous Following Moves
When a follower performs a preset (MCØ) move in Following mode (FOLEN1), the
commanded position is either incremental or absolute in nature, but it does have a commanded
endpoint. The direction traveled by the follower will be determined by the commanded
endpoint position, and the direction the master is counting.
Let’s illustrate this with an example. Assume all necessary set-up commands have been
previously issued for our follower (axis #1) and master so that distances specified are in
revolutions:
FOLRN3
FOLRD4
FOLEN1
FOLMD10
MC0
MA1
PSET0
D5
GO1
;
;
;
;
;
;
;
;
;
;
Set Following follower-to-master ratio numerator to 3
Set Following follower-to-master ratio denominator to 4
(ratio is 3 revs on the follower to 4 revs on the master)
Enable Following on axis #1
Set preset move to take place over 10 master revolutions
Set follower to preset positioning mode
Set follower to absolute positioning mode
Set current absolute position reference to zero
Set move distance to absolute position 5 revolutions
Initiate move to absolute position 5
If the master is stationary when the GO1 command is executed, the follower will remain
stationary also. If the master begins to move and master pulses are positive in direction, the
follower will begin the preset move in the positive direction. If the master pulses stop arriving
before 10 master revolutions have been traveled, the follower will also stop moving, but that
GO1 command will not be completed. If the master then starts to count in the negative
direction, the follower will follow in the negative direction, but only as far as it's starting
position. If the master continues to count negative, the follower will remain stationary. The
Chapter 7. Multi-Tasking
191
www.comoso.com
GO1 command will not actually be completed until the master has traveled at least 10
revolutions in the positive direction from where it was at the time the GO1 command was
executed. If the master oscillates back and forth between it's position at the start of the GO1
command to just under 10 revolutions, the follower will oscillate back and forth as well.
The master must be counting in the positive direction for any preset (MCØ) GO1s commanded
on the follower to be completed. If mechanics of the system dictate that the count on the
source of the master pulses is negative, a minus (-) sign should be entered in the FOLMAS
command so that Gem6K sees the master counts as positive.
Continuous follower moves (MC1) react much differently to master pulse direction. Whereas a
preset move will only start the profile if the master counts are counting in the positive
direction, a continuous move will begin the ramp to its new ratio following the master in either
direction. As long as the master is counting in the positive direction, the direction towards
which the follower starts in a continuous move is determined by the argument (sign) of the D
command. The follower direction is positive for D+ and negative for D-.
If the master is counting in the negative direction when follower begins a continuous move,
the direction towards which the follower moves is opposite to that commanded with the D
command. The follower direction is positive for D- and negative for D+.
If the master changes direction during a continuous follower move, the follower will also
reverse direction. As with standard continuous moves, the GO1 will continue until terminated
by S, K, end-of-travel limits, stall condition, or command to go to zero velocity. As with
preset moves, the sign on the FOLMAS command determines the direction of master counting
with respect to the direction of actual counting on the master input.
Master and Follower Distance Calculations
The formulas below show the relationship between master move distances and the
corresponding follower move distances. These relationships may be used to assist in the
design of Following mode moves in which both the position and duration of constant ratio are
important.
In such calculations, it is helpful to use SCLMAS and SCLD values which allow the master and
follower distances to be expressed in the same units (e.g., inches or millimeters). In this case,
many applications will be designed to reach a final ratio of 1:1, and the distances in these
figures can be easily calculated.
☞ HINT: For a trapezoidal preset follower axis move with a maximum ratio of 1:1, the
master and follower distances during the constant ratio portion will be the same. The
follower travel during acceleration will be exactly half of the corresponding master travel,
and it will also occur during deceleration.
Master Distance (FOLMD)
The FOLMD command determines the master distance over which the acceleration (mode
continuous moves – MC1) or the entire move (preset moves – MCØ) takes place. If the
follower axis is in continuous positioning mode (MC1), FOLMD is the master distance over
which the follower axis is to accel or decel from the current ratio to the new ratio. If the
follower axis is in preset positioning mode (MCØ), FOLMD is the master distance over which
the follower's entire move will take place.
When the Follower is in Continuous Positioning Mode (MC1)
FOLMD * (R2 + R1)
D =
2
where:
FOLMD = Master distance
R2 = New ratio (FOLRN ÷ FOLRD)
R1 = Current ratio (FOLRN ÷ FOLRD)
D = Follower distance traveled during ramp
192
Gem6K Series Programmer’s Guide
www.comoso.com
When the Follower is in Preset Positioning Mode (MCØ)
Trapezoidal
Follower Moves
Dmax = (FOLMD * Rmax)
D1 =
where:
FOLMD = Master distance
MD1 = Master distance during accel & decel ramps
(Dmax - D)
2
MD1 =
MD2 = Master distance during constant ratio
2 * D1
Rmax
D = Total follower axis preset distance commanded
D1 = Follower travel during accel and decel ramps
D2 = D - (2 * D1)
MD2
D2 = Follower travel during constant ratio
D2
= R
max
Dmax = Maximum follower distance possible
(assuming no accel or decel)
Rmax = Maximum ratio = FOLRN ÷ FOLRD
FOLMD = (2 * MD1) + MD2
D = (D 2 + 2 * D1) < D max
Ratio
R max
Trapezoidal profile if:
These Profiles
depict ratio vs.
distance
MD1
Triangular
Follower Moves
D
zero
FOLMD
zero
D1
MD2
MD1
Distance
D2
Ratio
=
=
2=
1=
D2
R max
Rectangular profile if:
D2
D1
MD
MD
D1
MD2
Distance
where:
FOLMD = Master distance
Rpeak = Peak ratio reached during move
Rpeak * FOLMD
D =
2
D = Total follower distance
R max
Triangular profile if:
R peak
Ratio
D < 1/2 D max
This Profile depicts
ratio vs. distance
Distance
Calculation
Example
D
Distance
FOLMD
In the example below, the desired travel during constant ratio is already contained in numeric
variable #1 (VAR1), and may have been read from thumbwheels or a DATA command. The
corresponding follower move distance (D) and FOLMD are calculated as shown:
VAR2=2
VAR3=2 * VAR2
VAR4=VAR1 + VAR2
VAR5=VAR1 + VAR3
FOLMD(VAR5)
D(VAR4)
GO1
;
;
;
;
;
;
;
Desired follower travel during accel and decel combined
Required master travel during these ramps
Move distance is constant ratio portion plus ramps
Master travel for entire follower move
Establish calculated master travel
Establish calculated follower travel
Make desired follower move
Similar calculations may be done for a series of continuous move ramps to ratios, separated
by GOWHEN for master cycle positions. These ramps may be repeated in a loop to create a
Chapter 7. Multi-Tasking
193
www.comoso.com
continuous cyclical follower profile..
Beware of Roundoff
Error (Scaling only)
Some potential for roundoff error exists if the scaling of a move distance or master distance by
SCLD and SCLMAS does not result in an integer number of steps. Some additional care must
be taken in the segment by segment construction of profiles using ramps to continuous ratio.
The Gem6K maintains a follower position command which is calculated from the commanded
constant ratios, the ramps to the new ratios, and the master travel over which these take place.
At the end of each ramp or constant ratio portion, this commanded position is calculated to the
nearest integer follower step. If the ratios and master travel result in a non-integer follower
travel for a segment, the fractional part of that segment's calculated travel will be lost. In a
cyclical application, repeated truncations could build up to a significant error. This may be
avoided through careful attention to design of the profile.
Using Other Features with Following
The Gem6K has many features that may be used in the same application as its Following
features. In some cases, having configured an axis as a follower with the FOLMAS command
will affect, or be affected by, the operation of other features, as described below.
Setups used by
FOLMAS
(Stepper Axes Only)
The FOLMAS command uses the drive resolution (DRES) and the velocity range (PULSE) data
to configure an axis as a follower. In order for this data to be used correctly, these commands
must be given before FOLMAS. These commands are not allowed after FOLMAS is given.
After FOLMAS is executed, the MC command may be used to change from incremental to
absolute positioning and back.
S (Stop) & K (Kill)
Commands
Stop (S) and Kill (K) commands cause the follower to do a non-Following decel, even if the
follower is in Following mode. A stop or a kill, buffered or immediate, will clear a pending
GOWHEN condition (clears AS bit #26).
Kill Conditions
Under default operation (FOLK0), certain error conditions (i.e., drive fault input active, or max.
position error limit exceeded) will cause the Gem6K to disable the drive and kill the Following
profile (follower’s commanded position loses synchronization with the master).
If you enable Following Kill (FOLK1), these error conditions will still disable the drive
(DRIVE0), but will not kill the Following profile. Because the Following profile is still running,
the controller keeps track of what the follower’s position should be in the Following trajectory.
To resume Following operation, resolve the error condition (drive fault, excessive position
error), enable the drive (DRIVE1), and command the controller to impose a shift to compensate
for the lapse/shift that occurred while the drive was disabled and the follower was not moving.
To impose the shift, assign the negative of the internally monitored shift value (PSHF) to a
variable (e.g., VAR1 = -1 * PSHF) and command the shift using a variable substitution in the
FSHFD command (e.g., FSHFD(VAR1)).
The FOLK command only preserves Following profiles; normal velocity-based profiles will be
killed regardless of the FOLK command.
GO Command
If a follower axis is in Following mode (FOLEN1), moves will ramp to a ratio (set with FOLRN
and FOLRD). If it is not in Following mode, moves will ramp to a velocity (V). Switching in
and out of Following mode does not change the value for final ratio or final velocity goals, but
simply changes which parameter is used as the goal.
Registration
Moves
Registration inputs may be enabled with the INFNCi-H command while an axis is a follower,
and registration moves may interrupt either a Following mode move or a time-based move.
The registration move itself, however, is always a time based move, and implements the
registration velocity with respect to a stationary reference. Any trigger input may be used as a
registration input or for any Following feature which uses triggers, even at the same time.
(see page 159)
194
Gem6K Series Programmer’s Guide
www.comoso.com
Enter/Exit
Following Mode
While Moving
The FOLENØ command may be executed while a follower axis is moving at constant ratio. In
this case, the current velocity becomes the constant velocity, and the follower may accelerate
or decelerate to other velocities. The FOLEN1 command may not be executed while the
follower axis is moving in the non-Following mode. Attempting to do so will result in the
error response “MOTION IN PROGRESS”.
Pause and
Continue
A program may be paused and continued, even if configured as a follower. The program does
not lose track of the master input, even though motion is stopped. As usual, if a program
finishes normally, or if COMEXS is set to zero (COMEXSØ), the program may not be continued.
If a program is resumed, partially completed Following moves will be completed; however, the
remainder of the move is completed over the entire original master distance (FOLMD value).
TVEL and TVELA
Commands
The TVEL and VEL commands have always reported an unsigned value (i.e. magnitude),
consistent with the fact that the V command is always positive, even if the move direction is
negative. When Following is enabled (FOLEN1), TVEL and VEL report the net magnitude of
commanded velocity due to following and/or shifting. For example, if the follower axis is
Following in the positive direction at 1 rps, TVEL reports 1.000. If a shift in the negative
direction of 1.5 rps is then commanded, TVEL will report 0.5 – still positive, even though the
net direction is negative.
By contrast, TVELA and VELA have always been signed. In the above example, TVELA will
report -0.5.
TASF, TAS & AS
Axis Status Bits
Axis Status (TASF, TAS and AS) bits 1-4 represent the motion status of an axis. Bits 1 and 2
represent the moving and direction status of the net motion of an axis, including the
combination of following and shifting.
Bits 3 and 4 represent acceleration and velocity, respectively. With Following disabled
(FOLENØ), the accel and velocity can only be due to a commanded time-based profile. With
Following enabled (FOLEN1), the net commanded velocity and accel could be due to
following the master and/or a simultaneous shift (time-based profile). Bits 3 and 4 only reflect
the acceleration and velocity status of the time-based profile, not the combined command.
For example, if the follower axis is Following in the positive direction at 1 rps, TAS reports
1ØØØ. If a continuous shift (FSHFC2) of 0.8 rps in the negative direction is then commanded,
TAS will report 1Ø1Ø, while the shaft is decelerating to 0.2 rps. When the continuous shift
velocity is reached, TAS will report 1ØØ1.
Changing
Feedback Sources
(Servo Axes only)
Changing feedback sources (SFB) may result in a follower axis Following its own feedback.
For this reason, changing feedback sources is not allowed while a master is specified
(FOLMAS).
Following and
Other Motion
Following motion is initiated with the GO command, just like normal motion. Other motion,
which does not depend on the motion of an external master, may not be used while a follower
axis is in Following mode (FOLEN1). These motion types include jog mode, joystick mode,
and homing. To use these motion types, Following must be disabled (FOLENØ) — see
Enter/Exit Following Mode While Moving above for precautions.
Conditional
Statements Using
PMAS
The master cycle position (PMAS) value may be used in the comparison argument of these
commands:
• WAIT & GOWHEN: If it is desired to WAIT or GOWHEN on a master cycle position of the
next master cycle, one master cycle length (value of FMCLEN) should be added to the
master cycle position specified in the argument. This allows commands that sequence
follower axis events through a master cycle to be placed in a loop. The WAIT or
GOWHEN command at the top of the loop could execute, even though the actual master
Chapter 7. Multi-Tasking
195
www.comoso.com
travel had not finished the previous cycle. This is done to allow a PMAS value which is
equal to the master cycle length to be specified and reliably detected.
• IF, UNTIL, & WHILE: These arguments use the instantaneous PMAS value. Be careful
to avoid specifying PMAS values that are nearly equal to the master cycle length
(FMCLEN), because rollover may occur before a PMAS sample is read.
Compiled Motion
Following profiles may be pre-compiled to save processing time. For details, refer to
page 142.
Troubleshooting for Following
(see also Chapter 8)
Following applications are often more complex than others, because motion of the followers is programmed as a function
of the motion of the master. This requires the motion of the master to be well characterized and accurately specified in the
program. It often requires an unfamiliar way of thinking about the motion of the desired follower. The table below offers
some possible reasons for troubles which may be encountered in achieving the desired follower motion.
Symptom
Possible Causes
Follower does not follow master
• Improper FOLMAS
• Poor connection if master is encoder
• Master running backward
• No encoder power (when the encoder is selected as the master)
Follower motion is
• FFILT command value too low
• Unnecessary FPPEN amplifies master roughness
Ratio seems wrong
• FOLRN and FOLRD follower-to-master ratio values are inaccurate,
possibly reversed
• SCLD or SCLMAS wrong
• Following limited by FMAXV or FMAXA (steppers only)
Follower profile wrong, or unrepeatable
• WAIT used where GOWHEN should be
Master/follower alignment drifts over
many cycles
• Roundoff error due to fractional steps resulting from SCLD or SCLMAS
and user's parameters
• Too little master travel between GOWHEN and GO1, desired PMAS is
missed
• Ratios and master distances specified result in fractional follower
steps covered during ramps, constant ratio
Follower lags Following position
(steppers only)
196
• Inhibited by FMAXV
• FMAXA clips acceleration peaks resulting from attempt to follow rough
master
Gem6K Series Programmer’s Guide
www.comoso.com
Error Messages
If an illegal programming condition is discovered while programming or executing programs, the Gem6K responds with an
error message. If a program execution error is detected, the program is aborted.
The table below lists all the error messages that relate to Following, and indicates the command and cause that may
generate them. These error messages are displayed only if the error level is set to level 4 with the ERRLVL4 command
(this is the default setting).
Error Message
Cause
FOLMAS NOT SPECIFIED
No FOLMAS for the axis is currently specified. It will occur if FMCNEW, FSHFC, or
FSHFD commands are executed and no FOLMAS command was executed, or
FOLMASØ was executed.
INCORRECT DATA
Velocity (V), acceleration (A), or deceleration (AD) command is zero. (used by
FSHFC & FSHFD)
INVALID CONDITIONS FOR
COMMAND
The FOLMD command value is too small to achieve the preset distance and still
remain within the FOLRN/FOLRD ratio.
A command phase shift cannot be performed:
FSHFD.............Error if already shifting or performing other time based move.
FSHFC.............Error if currently executing a FSHFD move, or if currently executing another
FSHFC move in the opposite direction.
The FOLEN1 command was given while a profile was suspended by a GOWHEN.
INVALID DATA
The parameter supplied with the command is invalid.
FFILT.............Error if:
FMCLEN...........Error if:
FMCP ...............Error if:
FOLMD.............Error if:
FOLRD.............Error if:
FOLRN.............Error if:
FSHFC.............Error if:
FSHFD.............Error if:
GOWHEN...........Error if:
WAIT ...............Error if:
smooth number is not 0-4
master steps > 999999999 or negative
master steps > 999999999 or <-999999999
master steps > 999999999 or negative
master steps > 999999999 or negative
follower steps>999999999 or negative
number is not 0-3
follower steps>999999999 or <-999999999
position > 999999999 or <-999999999
position > 999999999 or <-999999999
Error if a GO command is given in the preset positioning mode (MCØ) and:
FOLRN = zero
FOLMD = zero, or too small (see Preset Positioning Mode Moves on page 177)
INVALID FOLMAS SPECIFIED
An illegal master was specified in FOLMAS. A follower may never use its own
commanded position or feedback source as its master.
INVALID RATIO
Error if the FOLRN:FOLRD ratio after scaling is > 127 when a GO is executed.
MASTER SLAVE DISTANCE
MISMATCH
Attempting a preset Following move with a FOLMD value that is too small.
MOTION IN PROGRESS
The FOLEN1 command was given while that follower was moving in a non-Following
mode.
NOT VALID DURING
FOLLOWING MOTION
A GO command was given while moving in the Following mode (FOLEN1) and while
in the preset positioning mode (MCØ).
NOT VALID DURING RAMP
A GO command was given while moving in a Following ramp and while in the
continuous positioning mode (MC1). Following status (FS) bit #3 will be set to 1.
Chapter 7. Multi-Tasking
197
www.comoso.com
Following Commands
Detailed information about these commands is provided in the
Gem6K Series Command Reference.
ANIMAS ........................ Assigns an analog input to be used as a master in a FOLMAS assignment (requires a ANI SIM located on an
expansion I/O brick).
ERROR........................... Enable bit #14 to check for when a GOWHEN condition is already true when a subsequent GO, GOL, FGADV,
FSHFC, or FSHFD command is given.
ERRORP ........................ If ERROR bit #14 is enabled, a GOSUB branch to the error program occurs if a GOWHEN condition is already
true when a subsequent GO, GOL, FGADV, FSHFC, or FSHFD command is given.
FFILT........................... Sets the bandwidth for master position filtering.
FGADV........................... Defines the geared advance distance.
FMAXA........................... Stepper axes only: Sets the max. acceleration a follower may use while Following.
FMAXV........................... Stepper axes only: Sets the max. velocity at which a follower may travel.
FMCLEN ........................ Defines the length of the master cycle.
FMCNEW ........................ Restarts new master cycle counting immediately. To make this a trigger-based operation instead of issuing
the FMCNEW command, use the TRGFNcx1 command.
FMCP............................. Defines the initial position of a new master cycle.
FOLEN........................... Enables or disables Following mode.
FOLK............................. Allows drive fault or maximum position error to disable drive without killing the Following profile.
FOLMAS ........................ Defines master for follower.
FOLMD........................... Defines the master distance over which ratio changes or moves are to take place.
FOLRD........................... Establishes the DENOMINATOR ONLY for the max. follower-to-master ratio for a preset move or the final
ratio for a continuous move (use in combination with the FOLRN command).
FOLRN........................... Establishes the NUMERATOR ONLY for the max. follower-to-master ratio for a preset move or the final
ratio for a continuous move (use in combination with the FOLRD command).
FPPEN........................... Allows master position prediction to be enabled or disabled.
FSHFC........................... Allows continuous advance or retard (shift) of follower position during continuous Following moves.
FSHFD........................... Allows preset advance or retard (shift) of follower position during continuous Following moves.
FVMACC ........................ Establishes the rate at which the virtual master count frequency (FVMFRQ) may change for an axis.
FVMFRQ ........................ Defines the frequency of the virtual master count.
GOWHEN ........................ A GOWHEN command suspends execution of the next follower move until the specified conditional statement
(based on T, IN, LIM, PC, PE, PMAS, PSLV, or PSHF) is true. To make this a trigger-based operation
instead of issuing the GOWHEN command, use the TRGFNc1x command.
SCLD............................. Sets the follower distance scale factor.
SCLMAS ........................ Sets the master scale factor.
SINAMP ........................ Defines the amplitude of the internal sine wave.
SINANG ........................ Defines the phase angle of the internal sine wave.
SINGO........................... Initiates the internal sine wave.
TRGFN........................... aTRGFNc1x initiates a GOWHEN. Suspends execution of the next follower move on follower axis (a) until the
specified trigger input (c) goes active.
aTRGFNcx1 allows master cycle counting to be restarted on axis (a) when the specified trigger input (c)
goes active.
198
Gem6K Series Programmer’s Guide
www.comoso.com
Status and Assignment Commands:
TASF, TAS & [ AS ]......Bit 26 of each axis status is set (1) if a motion profile suspended by a GOWHEN (including TRGFNc1x) is
pending on that axis. The bit is cleared when the GOWHEN is true, or when a stop (S) or kill (K) command is
executed.
TERF, TER & [ ER ]......Bit 14 is set if the GOWHEN condition is already true when a subsequent GO, GOL, FGADV, FSHFC, or
FSHFD command is given. (The corresponding error-checking bits must be enabled with the ERROR
command before the error will be detectable.)
TFSF, TFS & [ FS ]......Transfers or assigns/compares the Following status or each axis.
TNMCY and [ NMCY ] ....Transfers or assigns the current master cycle number.
TPCMS and [ PCMS ] ....Transfers or assigns the current captured master cycle position.
TPMAS and [ PMAS ] ....Transfers or assigns the current master cycle position.
TPSHF and [ PSHF ] ....Transfers or assigns the net position shift since constant ratio.
TPSLV and [ PSLV ] ....Transfers or assigns the follower's current commanded position.
TVMAS and [ VMAS ] ....Transfers or assigns the current velocity of the master axis.
WAIT .............................A WAIT command suspends program execution until the specified conditional statement (based on PMAS,
FS, NMCY, PCMS, PSHF, PSLV, or VMAS) is true;
WAIT(SS.i=b1) suspends program execution until a trigger input is activated (“i” is the input bit number
corresponding to the trigger input—refer to the Gem6K Series Command Reference).
Chapter 7. Multi-Tasking
199
www.comoso.com
200
Gem6K Series Programmer’s Guide
www.comoso.com
Multi-Tasking
7
CHAPTER SEVEN
Multi-Tasking
IN THIS CHAPTER
• Introduction to Multi-Tasking .........................................................................202
• Using Gem6K Resources While Multi-Tasking..............................................210
• Multi-Tasking Performance Issues..................................................................214
• Multi-Tasking Application Examples .............................................................215
www.comoso.com
Introduction to Multi-Tasking
What is Multi-Tasking? Multi-tasking is the ability of the Gem6K to run more than one
program at the same time. This allows users to manage independent activities, aside from just
motion.
Why use Multi-Tasking?
• Multiple independent tasks can act on the same process or same axis.
• A supervisory program can control and coordinate multiple processes.
What is a Task? A system task is a program execution environment, not a program. Each
task runs independently. Each task can be used to run independent programs. Any task may
run any program. Multiple tasks could even be running the same program simultaneously.
Each task may either be:
• Running a program
• Monitoring ON, ERROR, or INSELP conditions
• Inactive (not running a program or monitoring conditions)
Using Multi-Tasking to Run Programs
Use the Wizard
Motion Planner provides
a Multi-Tasking wizard,
accessed from the
Editor. The wizard leads
you, step by step,
through the process of
setting up for multitasking.
Multi-tasking is initiated by the Task Supervisor. The supervisor is the Gem6K’s main
program execution environment — it runs the STARTP program and contains the command
buffer and parser. If the multi-tasking feature is not being used, the supervisor is the lone
program execution environment of the Gem6K, as shown in Figure 1. When multi-tasking is in
operation, the supervisor is referred to as “Task 0”.
GEM6K
Resources
Program Memory
I/O
move1
Inputs
Outputs
Limits
Triggers
math
inout
fill
Supervisor
Serial Ports
PORT1 (RS-232)
PORT2 (RS-232/485)
Ethernet
move2
seal
Run Start-up Program
Execute Programs
Monitor Conditions
gohome
move3
main
Axis
Command Buffer & Parser
Variables
VAR
VARB
VARI
VARS
Figure 1: Gem6K Supervisor, with no Multi-Tasking
The Gem6K can have a maximum of 10 tasks, in addition to the Task Supervisor (Task 0).
Each task acts as an individual program execution environment. The boxes shown under
Resources in Fig. 1, and the following Figures, represent the resources that the supervisor and
tasks monitor and manipulate (see list below). These resources can be shared with other tasks.
• I/O..................................Inputs and Outputs (onboard I/O and expansion I/O bricks)
• Communication ports ....“RS-232”, “RS-232/485”, and “ETHERNET”
202
Gem6K Series Programmer’s Guide
www.comoso.com
• Axis .............................. The Gem6K axis can be shared with any tasks
• Variables ...................... Real (VAR), binary (VARB), integer (VARI), and string (VARS)
“Program Memory” is the Gem6K’s non-volatile memory where programs are stored. Any
task may run any program. Multiple tasks could even be running the same program
simultaneously. Programs in multi-tasking are defined as they typically are with the Gem6K
GEM6K
Resources
Supervisor
I/O
Run Start-up Program
Execute Programs
Monitor Conditions
Inputs
Outputs
Limits
Triggers
Program Memory
move1
math
Command Buffer & Parser
inout
fill
Task 1
Serial Ports
PORT1 (RS-232)
PORT2 (RS-232/485)
Ethernet
Axis
move2
seal
Execute Programs
Monitor Conditions
gohome
move3
main
Task 2
Execute Programs
Monitor Conditions
Variables
VAR
VARB
VARI
VARS
Task 10
Execute Programs
Monitor Conditions
Figure 2: Gem6K8 - Multi-Tasking with 10 tasks.
The Task Identifier (%) prefix is used to specify that the associated command will affect the
indicated task number. For most simple multi-tasking applications, the % prefix will only be
used to start a program running in a specific task. Multi-tasking programs can be started
through the communication ports (see Figs. 3a-3c), or from a program (see Figs. 4a-4d). Note
that the programs are run in the tasks specified with the % prefix.
Starting Tasks from
a Communications
Port
GEM6K
Resources
Supervisor
Program Memory
1%move1
I/O
RUN main
1%move1
1%move1
Serial Ports
Ethernet
move1
1%move1
DEF move1
Axis
Task 1
END
RUN move1
Variables
Figure 3a: Multi-Tasking initiated from a computer terminal.
Chapter 8. Troubleshooting
203
www.comoso.com
GEM6K
Resources
Supervisor
Program Memory
2%inout
I/O
2%inout
2%inout
move1
Serial Ports
Task 1
Ethernet
Running
move1
Axis
DEF move1
_
_
_
END
inout
Task 2
Run
inout
DEF inout
_
_
_
END
2%inout
Variables
Figure 3b: Multi-Tasking initiated from a computer terminal (cont’d).
GEM6K
Resources
Supervisor
Program Memory
3%fill
I/O
move1
3%fill
3%fill
Serial Ports
Task 1
Ethernet
Running
move1
DEF move1
_
_
_
END
Axis
inout
Task 2
Running
inout
DEF inout
_
_
_
END
fill
Task 3
Variables
Run
fill
3%fill
DEF fill
_
_
_
END
Figure 3c: Multi-Tasking initiated from a computer terminal (cont’d).
Starting Tasks from
a Program
GEM6K
Resources
Supervisor
I/O
RUN main
Serial Ports
Ethernet
Axis
Variables
Figure 4a: Multi-Tasking initiated from a program.
204
Gem6K Series Programmer’s Guide
Program Memory
main
RUN main
RUN main
DEF main
_
_
_
1%move1
2%inout
3%fill
END
www.comoso.com
GEM6K
Resources
Supervisor
main
Running
I/O
Program Memory
main
1%move1
1%move1
1%move1
2%inout
3%fill
END
Serial Ports
1%move1
Ethernet
DEF main
_
_
_
Task 1
move1
Axis
DEF move1
_
_
_
RUN move1
Variables
END
Figure 4b: Multi-Tasking initiated from a program (cont’d).
GEM6K
Resources
Supervisor
main
Running
I/O
Program Memory
main
2%inout
2%inout
1%move1
2%inout
3%fill
END
Serial Ports
Ethernet
Task 1
Running
Axis
DEF main
_
_
_
move1
move1
DEF move1
_
_
_
END
Task 2
inout
RUN inout
DEF inout
_
_
_
2%inout
Variables
END
Figure 4c: Multi-Tasking initiated from a program (cont’d).
GEM6K
Resources
Supervisor
Running
I/O
3%fill
Task 1
Running
Axis
3%fill
DEF main
_
_
_
1%move1
2%inout
3%fill
END
Serial Ports
Ethernet
Program Memory
main
main
move1
move1
DEF move1
_
_
_
END
Task 2
Running
inout
inout
DEF inout
_
_
_
Variables
Task 3
RUN fill
3%fill
END
fill
DEF fill
_
_
_
END
Figure 4d: Multi-Tasking initiated from a program (cont’d).
Chapter 8. Troubleshooting
205
www.comoso.com
Interaction Between Tasks
A new task is initiated by identifying the task number with the Task Identifier (%) prefix,
followed by the name of the program to be run in the specified task. Because the % prefix
specifies the task number that the associated command will affect, new tasks can be started
from within other tasks. Fig. 5b shows the move1 program in task 1 being started by the
main program in the supervisor. Fig. 5c shows the fill program in task 3 being started by
the move1 program in task 1 with the 3%fill command. Fig. 5d shows the inout
program in task 2 being started by the fill program in task 3 with the 2%inout command.
Program execution in a task is controlled by commands executed from the program the task is
running. In the example shown in Figs 5a-5d, program execution in Task 1 is controlled by
commands executed from the move1 program, program execution in Task 2 is controlled by
commands executed from the inout program, and program execution in Task 3 is controlled
by commands executed from the fill program.
GEM6K
Resources
Supervisor
Program Memory
main
RUN main
I/O
RUN main
RUN main
DEF main
1%move1
_
_
_
Serial Ports
END
Ethernet
Axis
Variables
Figure 5a: Initiating multi-tasking.
GEM6K
Resources
I/O
Supervisor
Running
main
main
1%move1
Serial Ports
Ethernet
RUN move1
206
Gem6K Series Programmer’s Guide
DEF main
1%move1
_
_
_
END
Task 1
Figure 5b: Task initiated from another task (cont’d).
1%move1
1%move1
Axis
Variables
Program Memory
move1
DEF move1
3%fill
_
_
END
www.comoso.com
GEM6K
Resources
Supervisor
Running
I/O
Program Memory
main
main
DEF main
1%move1
_
_
_
Serial Ports
END
Ethernet
Task 1
Running
Axis
move1
move1
3%fill
3%fill
DEF move1
3%fill
_
_
END
Variables
3%fill
Task 3
fill
RUN fill
DEF fill
2%inout
_
_
END
Figure 5c: Task initiated from another task (cont’d).
GEM6K
Resources
Supervisor
Program Memory
main
Running
I/O
main
DEF main
1%move1
_
_
_
Serial Ports
END
Ethernet
Task 1
Running
Axis
move1
move1
DEF move1
3%fill
_
_
END
Variables
Task 2
inout
RUN inout
2%inout
DEF inout
_
_
_
END
Task 3
Running
fill
fill
2%inout
2%inout
DEF fill
2%inout
_
_
END
Figure 5d: Task initiated from another task (cont’d).
Chapter 8. Troubleshooting
207
www.comoso.com
Tasks
The default condition in multi-tasking is that each task is associated with motion, as shown in
Fig. 6a. This means that when a task associated with motion hits an end-of travel limit,
program execution will be killed within that task. It may therefore be necessary to unassign
motion association for a given task to allow an independent program execution environment.
When this is done, the unassigned task cannot control or quary any information about the
motor or motion.
Refer to page 210 for
more details about
associating axes with
tasks.
The TSKAX command allows you to unassign the motion from the task. By assigning the task
to no motion(TSKAX0), the task can not control or query information on the Gem6K motor or
motion..
GEM6K
Resources
Supervisor
I/O
Run Start-up Program
Execute Programs
Monitor Conditions
Inputs
Outputs
Limits
Triggers
Program Memory
move1
math
Command Buffer & Parser
inout
fill
Task 1
Serial Ports
PORT1 (RS-232)
PORT2 (RS-232/485)
Ethernet
move2
seal
Execute Programs
Monitor Conditions
gohome
move3
Default = All Axes
main
Task 2
Execute Programs
Monitor Conditions
Axes
Default = All Axes
Variables
VAR
VARB
VARI
VARS
Task 10
Execute Programs
Monitor Conditions
Default = All Axes
DEF main
1%TSKAX1
2%TSKAX0
1%move1
2%inout
END
208
Gem6K Series Programmer’s Guide
;
;
;
;
;
;
;
Begin definition of program called "main"
Associate task 1 with motion
Do not associate task 2 with motion)
Execute the "move1" program in Task 1
Execute the "inout" program in Task 2 (Will not affect any
motion)
End definition of program called "main"
www.comoso.com
How a “Kill” Works While Multi-Tasking
The general rule of command execution within a task is that the command affects only the
task in which it was executed or to which it was directed via the % prefix. This includes
almost all motion commands when tasks have an associated (TSKAX) axis. The exception is
the Kill command. A “K” or “!K” without prefix or parameters will kill all controller axes,
and programs running in all tasks. This exception is made to allow one short, familiar
command to effectively stop all controller processes. As usual, a “K” with parameters (e.g.,
Kx11) will kill motion only on the specified axis, and will not kill the program. A “K”
prefixed with a task specifier but without parameters (e.g., 3%K) will kill the program and
motion if the task has an associated axis.
Certain inputs can be used to kill programs and motion. These inputs and their results under
multi-tasking are:
• Drive Fault input. Kills program execution and the associated axis for all tasks that are
associated with the faulted axis.
• Kill input (INFNCi-C or LIMFNCi-C). If prefixed with the task identifier (e.g.,
2%INFNC3-C), it will kill the designated task, its program and the associated axis. If not
prefixed with a task identifier, it will kill the controller axis, and all programs running
in all tasks. It will also cause a branch to the task’s error program if the task’s errorchecking bit 6 is enabled (n%ERROR.6-1).
• User fault input (INFNCi-F or LIMFNCi-F). This input functions the same as the kill
input noted above, with the exception that it will also cause a branch to the task’s error
program if the task’s error-checking bit 7 is enabled (n%ERROR.7-1).
Chapter 8. Troubleshooting
209
www.comoso.com
Using Gem6K Resources While Multi-Tasking
Associating Axes with Tasks
The default condition in multi-tasking is that each task is associated with motion. The TSKAX
command allows you to unassign the task from the motion, thus constraining task response
and control to I/O only. The TSKAX command allows you to specify motion (1) or no motion
(0). This association covers all interaction between axes commands, conditions or inputs and
task program flow, including the following:
• Motion data commands (e.g., A, V, D). These commands will apply only if the task is
associated with motion.
• Stop, pause, and continue commands and inputs. These commands will affect motion
only on tasks associated with motion: S (stop) command — without parameters, PS
(pause) command, and C (continue) command. Inputs programmed with these functions
will affect motion only on tasks associated with motion and specified in the input
function assignment (with the n% prefix): Kill input (n%INFNCi-C or n%LIMFNCi-C),
stop input (n%INFNCi-D or n%LIMFNCi-D), pause/continue input (n%INFNCi-E or
n%LIMFNCi-E), and user fault input (n%INFNCi-F or n%LIMFNCi-F).
• Drive fault and limit inputs. If a drive fault or end-of-travel limit occurs, only tasks
assocaited with motion will be killed.
• ON conditions. Axis status bits are only monitored if the task is associated with
motion.
• ERROR conditions. Each task has its own error status register (ER, TER, TERF), errorchecking bits (ERROR), and error program (ERRORP).
• Command buffer control:
− COMEXC. Pauses command processing of that task until the associated motion
has stopped
− COMEXL. Allows the specified associated motion to not kill that task’s
program.
210
Gem6K Series Programmer’s Guide
www.comoso.com
Sharing Common Resources Between Multiple Tasks
Controller resources other than processing time must also be shared between multiple tasks.
All physical inputs and outputs are shared (i.e., each task may read all inputs and write to all
outputs). Some of the functions associated with that I/O (defined with LIMFNC, INFNC and
OUTFNC commands) are unique for each task. All variables (VAR, VARI, VARB, VARS),
DATA programs, and the DATPTR are shared. If one task modifies a variable, a DATA
program, or DATPTR, the new value is the same for all tasks. There are no “private” variables.
The serial ports are shared (i.e., any task may read from, or write to, any serial port). When a
task writes to a serial port, the characters are all sent to the output buffer at once, but
execution proceeds to the next command without waiting for those characters to be
transmitted.
The data assignment functions READ, DREAD, or DREADF, and TW are also shared between
tasks, but in these cases, the task is not allowed to execute the next command until the data
has been received and assigned. This requires waiting for human or host input, or
thumbwheel strobe time. During this time, that task is “blocked”, and that data assignment
function (READ, DREAD, or DREADF, or TW) is owned by the blocked task. If another task is
active, it will continue to execute commands. If this second task attempts to access a data
assignment function which is still owned by the first task, the second task becomes blocked
also. This situation persists until the first task receives and assigns its data. At that point,
ownership of the data assignment function passes to the second task, until it too receives and
assigns its data. All this blocking and ownership is automatic, not requiring coordination by
the user.
Locking Resources to a Specific Task
Examples:
LOCK1,1 locks COM1
LOCK1,0 unlocks COM1
LOCK2,1 locks COM2
LOCK2,0 unlocks COM2
LOCK3,1 locks swapping
LOCK3,0 unlocks swapping
The LOCK command may be used by a system task to gain or release exclusive ownership of a
resource. This will allow that task to complete a sequence of commands with that resource
while preventing another task from using the resource in between commands. Any other task
attempting to access or LOCK that resource will become blocked (i.e., become temporarily
totally inactive) until the resource is released by the task that owns it. Resources which may be
LOCKed are:
• COM1 — the “RS-232” connector or the “ETHERNET” connector
• COM2 — the “RS-232/485” connector
• Task Swapping — When task swapping is locked to a specific task, command
statements in all other tasks will not be executed until the task swapping is again
unlocked. For more information on task swapping, refer to page 214.
NOTE: A resource may be locked by a task only while that task is executing a program. If
program execution is terminated for any reason (e.g., stop, kill, limit, fault, or just reaching the
END of a program), all resources locked by that task will become unlocked.
For example, to report the current position of a robotic arm, one might program:
VAR10 = 1PM
;
LOCK1,1
;
WRITE "Arm Position is"
;
WVAR10
;
WRITE "inches\13"
;
LOCK1,0
;
; Between the LOCK commands,
; attempt to access COM1, in
; temporarily blocked.
position of axis one
lock COM1 ("RS-232" port) resource
write string
write position
write string and carriage return
release COM1 to other tasks
other tasks will run unless they
which case they become
How Multi-tasking and the % Prefix Affect Commands and Responses
Multi-tasking affects many, but not all, of the Gem6K commands and features. The table
below lists the commands that are affected by multi-tasking and the task-identifier (%) prefix.
Any command that is not listed may be considered unaffected by multi-tasking. Any
Chapter 8. Troubleshooting
211
www.comoso.com
command which has motion data (e.g., A, V, D) is only affected if the task has been associated
with motion via the TSKAX command. Any command listed below as affected by the % prefix
may also accept the @ character as a task number; in this case, all tasks will be affected by the
command.
The response (if any) sent to the terminal by the command will be prefixed with the task
number and % sign if the command had been executed by any task other than Task 0, the
Supervisor Task. For commands executed in Task 1, if the command itself had the 1% prefix,
then the response will also have the prefix. Otherwise, the response will not be prefixed.
Therefore, if no multi-tasking is used, no responses will have task prefixes. If multi-tasking is
used, however, you can determine which task originated the response. A response could be
the result of a transfer command (e.g., TER), a command with no parameters (e.g. MC),
TRACE output, or an error message.
212
Command(s)
Effect of % Prefix
Effect of Multi-tasking
GOTO, IF, ELSE, NIF,
WHILE, NWHILE, REPEAT,
UNTIL, L, LN, LX
None (ignored)
These commands direct program flow
only on the task from which they are
executed.
GOSUB, RUN, <progname>,
JUMP, HALT, BP, PS, T,
WAIT, C
Effectively inserts
command into
numbered task’s
program
These commands initiate, interrupt or
continue program flow only on
implicitly or explicitly specified task.
COMEXC, COMEXR, COMEXS
Affects mode on
numbered task
These commands affect program flow
only on implicitly or explicitly specified
task.
S, K
Specifies affected
task only
These commands affect program flow
(depending on parameters given)
only on implicitly or explicitly specified
task. A “K” with no prefix or
parameters kills all tasks.
ERROR, ERRORP, TER,
TERF, ER
Affect/report on
numbered task
These commands affect/report error
conditions and programs only on
implicitly or explicitly specified task
(each task has its own error status
register and error program).
TCMDER, TSS, TSSF, SS,
TSTAT
Report on numbered
task
These commands report command
errors and status only on implicitly or
explicitly specified task.
TTIM, TIMINT, TIMST,
TIMSTP, TIM
Command refers to
timer of numbered
task
Each task has an independent timer.
Also, TIMST0,# resets the timer to #
msec., TIMST1,# restarts the timer
with the TIM value of task #.
TRACE, TRACEP, TEX,
STEP, #
Command refers to
numbered task
Each task has its own trace and step
mode. This allows tracing on a single
task, or combined tasks commands.
ONCOND, ONIN, ONP, ONUS,
ONVARA, ONVARB
Command refers to
numbered task
Each task has its own set of ON
conditions and its own ONP program.
LIMFNCi-C, LIMFNCi-D,
LIMFNCi-E, LIMFNCi-F,
LIMFNCi-P,
INFNCi-C, INFNCi-D,
INFNCi-E, INFNCi-F,
INFNCi-P,
INSELP, OUTFNCi-C
Command refers to
numbered task
These functions are task specific. All
others affect the entire controller and
cannot be affected by the % prefix.
Gem6K Series Programmer’s Guide
www.comoso.com
Input and Output Functions and Multi-tasking
The Gem6K has inputs and outputs (onboard and on external optional I/O bricks) that may be
assigned various I/O functions with these function assignment commands:
LIMFNC........ Assigns input functions to the dedicated limit inputs on the “LIMITS/HOME”
connectors (factory default functions are the respective R, S, and T limit
input functions).
INFNC .......... Assigns input functions to the onboard digital inputs (trigger input on the
“TRIGGERS/OUTPUTS” connectors) and to the digital inputs on external I/O
bricks.
OUTFNC........ Assigns output functions to the onboard digital outputs (outputs on the
“TRIGGERS/OUTPUTS” connectors) and to the digital outputs on external I/O
bricks.
The Gem6K’s I/O and events involving programmed I/O are related to tasks only if:
• The input or output function assignment is associated with a specific task. For example,
because of the 1% prefix, the 1%INFNC3-F command assigns the “user fault” function
to onboard input 3 and directs its function to be specific to Task 1.
• An input or output is assigned a specific function and the input or output is associated
with a specific task. For example, if Task 1 is associated with motion (1%TSKAX1) and
onboard input 4 is assigned as a “stop” input (INFNC4-D), then when onboard input 4
goes active motion is stopped; thus Task 1 is affected by input 4.
Each input or output group (LIMFNC, INFNC, and OUTFNC) is limited to a maximum of 32
function assignments at one time. Exceptions are: function A, LIMFNC functions R, S, and T,
and INFNC function H. A given input or output may be assigned only one function, although
for task-specific functions, this I/O point may perform the same function for multiple tasks
(by using the % prefix). This only counts as one function against the maximum total of 32,
even though it is shared by multiple tasks. A given I/O point may not perform different
functions for different tasks. Re-assigning a I/O point’s function in any (same or different)
task will result in removing the assignment of the previous function in the previous task(s).
For example:
1%2INFNC4-C
2%2INFNC4-C
3%2INFNC4-D
;
;
;
;
module 2's 4th input will kill task 1
module 2's 4th input now kills tasks 1 & 2
module 2's 4th input will stop task 3,
it no longer has a kill function for tasks 1 & 2
Chapter 8. Troubleshooting
213
www.comoso.com
Multi-Tasking Performance Issues
When is a Task Active?
Tasks are always ready to become active if commanded to do so. No special command is
required to allow a task to do something. A task is active if it is:
•
•
•
•
•
•
Executing a program (SS.3=B1)
Executing a T or WAIT command (even if not running a program)
Monitoring drive faults conditions (DRFEN1)
Monitoring ONCOND conditions (SS.15=B1)
Waiting in Program Select Mode (INSELP1 and SS.18=B1)
Monitoring ERROR conditions (ERROR has any non-zero bit)
A task becomes active when it receives a command to perform something from the list above.
A task which is not active does not create any overhead (delays) in command processing for
tasks which are active. Once a task becomes active, however, it takes its turn in the sequence
of swapping (see below), and checks for all of the conditions listed above. This adds a
processing burden which will slow the command execution rate of programs running in other
tasks.
A task becomes inactive if nothing from the above list is occurring. There is no special
command “kill task” to disable all these modes/conditions/activities at once. The standards
methods for terminating these (S, INSELP0, ERROR0, etc.) are needed to make a task
completely inactive, and therefore not creating command processing overhead. Task 0, the
Task Supervisor, will always be active, even if nothing from the above list is occurring,
because Task 0 always checks the input command buffer for commands to execute.
The TSWAP command reports a binary bit pattern indicating the tasks that are currently active.
Bit 1 represents task 1, bit 2 represents task 2, etc. A “1” indicates that the task is active, and
a “0” indicates that the task is inactive. The SWAP assignment operator allows the same
information to be assigned to a binary variable, or evaluated in a conditional statement such as
IF or WAIT. This is useful for determining which tasks have any activity, whereas the system
status (SS) and error status (ER) states reveal exactly what activity a given task has at that
time.
Task Swapping
The Gem6K has only one processor responsible for executing programs, therefore, multiple
tasks are not actually executing simultaneously. Tasks take turns executing when they are
active. A task’s “turn” consists of executing one command and checking its input, output, ON,
ERROR and INSELP conditions before relinquishing control to the next task. The process of
changing from one task to the next is called task swapping. The Gem6K determines when to
swap tasks. The user is not required (or allowed) to determine how long a task should run, or
when to relinquish control to another task.
Although the user does not determine how long a task should run, or when to relinquish
control to another task, the number of “turns” a task gets before swapping may be set with the
TSKTRN command. The default value is one for all active tasks. Thus, each task has equal
weight, swapping after every command. If a task needs a larger share of processing time
however, the TSKTRN value for that task can be increased. For example, if task 2 issued a
TSKTRN6 command, while the others stayed at 1, programs running in task 2 would execute
six commands before relinquishing. The TSKTRN value for a task may be changed at any
time, allowing a task to increase its weight for an isolated section of program statements.
The TTASK command reports to the display the task number of the task which executed the
214
Gem6K Series Programmer’s Guide
www.comoso.com
command. This could be used for diagnostic purposes, as a way to indicate which task is
executing a given section of program. The corresponding TASK assignment allows the
program itself to determine which task is executing it. The current task number TASK may be
assigned to a variable or evaluated in a conditional statement such as IF. This allows a single
program to be used as a subroutine called from programs running in all tasks, yet this routine
could contain sections of statements which are executed by some tasks and not others.
Task Execution Speed
Two terms describe the execution speed of tasks in multi-tasking environments.
Performance
Performance is a measure of how fast a task executes commands, and could be described in
terms of commands per second. Because tasks must take turns executing, performance will
decrease when tasks are added. For example, the performance of a task sharing the controller
with two other tasks will be just one third of its performance if it were running by itself. Using
the TSKTRN command described above, the relative performances of tasks may be altered.
Determinism
Determinism is a measure of how independent the performance of one task is from the
commands and conditions involved in another task. If task swapping were done via a periodic
interrupt (time slicing), task performance would be completely determinate, i.e., each task
would run exactly for its time slice, not more or less. In the Gem6K products, task swapping is
not time sliced, rather each task is allowed to execute one command and check its input,
output, ON, ERROR and INSELP conditions before relinquishing control to the next task. For
this reason, the performance of each task is somewhat determined by the commands and
conditions underway in the other tasks. Most commands execute in approximately the same
time. The others (some math commands, and line and arc commands) are broken into sections
with durations that approximate those of the average command (approximately 2 ms).
Swapping also takes place between these sections, allowing all task performance to be
reasonably determinate regardless of which commands are being executed by other tasks.
Although time slicing would give completely determined task performance, the task swapping
would need to include additional task save and restore functions to completely protect the task
from the interrupt. This additional overhead would effectively rob processor time from the
time slice, resulting in lower task performance. Task swapping in the Gem6K product does not
add this overhead, and is therefore extremely efficient, taking less than 0.5% of task execution
time.
Chapter 8. Troubleshooting
215
www.comoso.com
216
Gem6K Series Programmer’s Guide
www.comoso.com
Troubleshooting
8
CHAPTER EIGHT
Troubleshooting
IN THIS CHAPTER
• Troubleshooting basics ..............................................................................218
• Solutions to common problems (problem/cause/remedy table).................218
• Program debug tools
- Status commands ............................................................................222
- Error messages ................................................................................229
- Trace mode......................................................................................232
- Single-step mode.............................................................................234
- Break points ....................................................................................235
- Simulating programmable I/O activation........................................235
- Simulating analog input activation..................................................237
- Motion Planner’s Panel Gallery ......................................................237
• Technical support.......................................................................................238
• Operating system upgrades ........................................................................238
• Product return procedure ...........................................................................238
www.comoso.com
Troubleshooting Basics
When your system does not function properly (or as you expect it to operate), the first thing
that you must do is identify and isolate the problem. When you have accomplished this, you
can effectively begin to resolve the problem.
The first step is to isolate each system component and ensure that each component functions
properly when it is run independently. You may have to dismantle your system and put it
back together piece by piece to detect the problem. If you have additional units available, you
may want to exchange them with existing components in your system to help identify the
source of the problem.
Determine if the problem is mechanical, electrical, or software-related. Can you repeat or recreate the problem? Random events may appear to be related, but they are not necessarily
contributing factors to your problem. You may be experiencing more than one problem. You
must isolate and solve one problem at a time.
Log (document) all testing and problem isolation procedures. Also, if you are having
difficulty isolating a problem, be sure to document all occurrences of the problem along with
as much specific information as possible. You may need to review and consult these notes
later. This will also prevent you from duplicating your testing efforts.
Once you isolate the problem, refer to the problem solutions contained in this chapter. If the
problem persists, contact your local technical support resource (see Technical Support below).
Electrical Noise
If you suspect that the problems are caused by electrical noise, refer to your Gem6K product's
Installation Guide for help.
Solutions to Common Problems
NOTES
• Some hardware-related causes are provided because it is sometimes difficult to identify a
problem as either hardware or software related.
• Refer to other sections of this manual for more information on controller programming
guidelines, system set up, and general feature implementation. You may also need to
refer to the command descriptions in the Gem6K Series Command Reference. Refer to
your product’s Installation Guide for hardware-related issues.
Problem
Cause
Solution
Communication (Ethernet)
errors.
1. Ethernet card not installed
correctly.
1. Refer to the user instructions that came with your Ethernet
card.
2. Ethernet IP address
conflict.
2. Change IP address with the NTADDR command. (make sure it is
matched by the setup in Motion Planner)
3. Connection to Ethernet port
is compromised or miswired.
1. Improper interface
connections or communication
protocol.
2. COM port disabled.
3. Refer to the connection instructions in the Installation Guide.
Communication (serial) not
operative, or receive garbled
characters.
3. In daisy chain, unit may not
be set to proper address.
218
Gem6K Series Programmer’s Guide
1. See troubleshooting section in your product’s Installation Guide.
2.a. Enable serial communication with the E1 command.
2.b. If using RS-485, make sure the internal jumpers are set
accordingly (see Installation Guide). Make sure COM 2 port is
enabled for sending Gem6K language commands (execute the
PORT2 and DRPCHKØ commands).
3. Verify DIP switch settings (see Installation Guide), verify proper
application of the ADDR command.
www.comoso.com
Problem
Cause
Solution
Direction is reversed.
(stepper axes only)
1. Phase of step motor
reversed (motor does not
move in the commanded
direction).
2. Phase of encoder reversed
(reported TPE direction is
reversed).
1. Not tuned properly.
1. Switch A+ with A- connection from drive to motor.
Direction is reversed, servo
condition is unstable.
(servo axes only)
Distance, velocity, and accel
are incorrect as programmed.
2. Swap the A+ and A– connection at the ENCODER connector.
1. Refer to tuning instructions in your product's Installation Guide.
2. Phase of encoder reversed.
2. Software remedy for encoder feedback only: For the affected
axis, issue ENCPOL1.
Hardware remedy: If using encoder feedback, swap the A+ and
A- connections to the Gem6K product. If using ANI feedback,
change the mounting so that the counting direction is reversed.
1. Incorrect resolution setting.
1.a. Stepper axes: Set the resolution on the to match the Gem6K
product’s DRES command setting (default DRES setting is 4,000
steps/rev).
1.b. Match the Gem6K product's ERES command setting (default
ERES setting is 4,000 counts/rev) to match the post-quadrature
resolution of the encoder.
ERES values for Compumotor encoders:
Stepper axes:
• RE, -RC, -EC, & -E Series Encoders:..... ERES4000
• HJ Series Encoders:............................... ERES2048
Servo axes (SM, BE, N or J Series Servo Motors):
• SM/N/JxxxxD-xxxx:................................. ERES2000
• SM/N/JxxxxE-xxxx: ................................. ERES4000
• BExxxxJ-xxxx: ........................................ ERES8000
Erratic operation.
Feedback device (encoder or
resolver) counts missing.
2. Wrong scaling values.
3. Check the scaling parameters (SCALE1, SCLA, SCLD, SCLV,
SCLMAS) – see also page 67.
1. Electrical Noise.
1. Reduce electrical noise or move product away from noise
source.
2. Improper shielding.
3. Improper wiring.
1. Improper wiring.
2. Refer to the instructions in your product’s Installation Guide.
3. Check wiring for opens, shorts, & mis-wired connections.
1. Check wiring.
2. Feedback device slipping.
3. Encoder too hot.
2. Check and tighten feedback device coupling.
3. Reduce encoder temperature with heatsink, thermal insulator,
etc.
4a. Shield wiring.
4b. Use encoder with differential outputs.
5. Peak encoder frequency must be below 8 MHz postquadrature. Peak frequency must account for velocity ripple.
4. Electrical noise.
Following problems —
5. Encoder frequency too
high.
See page 196
Index
219
www.comoso.com
Diagnostic LEDs:
Both LED’s are off.
Left LED is Red, Right LED is
Green
All other LED states indicate
hardware conditions; refer to
your product's Installation
Guide for details.
1. No power.
Note: There are two diagnostic LED’s on the Gem6K. The left
hand LED shows Green or Red, the right hand LED shows Yellow
or Green.
1. Check 120/240VAC power connection and 24VDC power
connection and restore power as necessary.
1. 24VDC power only, no AC
applied.
2. Operating system download
in progress.
3. Operating system download
aborted before successful
completion.
1. Drive faulted.
2. Operating system download
in progress.
3. Operating system download
aborted before successful
completion.
1. Check 120/240VAC power connection and restore power as
necessary.
2. Wait for download to finish before resetting drive or cycling
power.
3. Contact Applications for help on recovering after an aborted
operating system download (or see web site FAQ).
Left LED is not illuminated,
Right LED is Yellow.
1. Initialization in progress.
This occurs during power-up
and reset.
1. Wait for unit to complete its power up or reset process.
Left LED is Green, Right LED
is flashing Yellow/Green
1. Drive is in auto-run mode
(DMODE13)
1. Change mode back to position mode (DMODE12).
Motion does not occur.
1. LED’s not lit at all (no
power) or red LED is
illuminated
1. See LED troubleshooting as noted above.
2. End-of-travel limits are
active.
2.a. Move load off of limits or disable limits by sending the LHØ
command to the affected axis.
2.b. Software limits: Set LSPOS to a value greater than LSNEG.
Left LED is Red, Right LED is
not illuminated.
1. Check status with TASF and TASXF commands to determine
cause and correct error condition as necessary.
2. Wait for download to finish before resetting drive or cycling
power.
3. Contact Applications for help on recovering after an aborted
operating system download (or see web site FAQ).
3. Improper wiring.
5. Check enable & limit connections..
4. ENABLE input is not
grounded.
5. Load is jammed.
6. No torque from motor.
6. Ground the ENABLE input connection.
7. Remove power and clear jam.
8. See problem: Torque, loss of.
7. Max. position error (SMPER
value) exceeded. (servo axes
only)
9. Check to see if TAS/TASF bit #23 is set, and issue the DRIVE1
command to the axis that exceeded the position error limit.
8. Drive has faulted.
10. Check to see if TAS/TASF bit #14 is set.
1. ENABLE input is not
grounded.
1. Ground the ENABLE input to GND and reset the product.
2. STARTP program is not
defined.
2. Check the response to the STARTP command. If no program is
reported, define the STARTP program and reset (see page 13, or
refer to the STARTP command description).
Program access denied:
receive the message
*ACCESS DENIED when
trying to use the DEF, DEL,
ERASE, LIMFNC, INFNC, or
MEMORY commands.
1. Program security function
has been enabled (INFNCi-Q
or LIMFNCi-Q) and the
program access input has not
been activated
1.a. Activate the assigned program access input, perform your
programming changes, then deactivate the program access input.
Program execution: the first
time a program is run, the
move distances are incorrect.
Upon downloading the
program the second time,
move distances are correct.
1. Scaling parameters were
not issued when the program
was downloaded; or scaling
parameters have been
changed since the program
was defined.
1. Issue the scaling parameters (SCALE1, SCLA, SCLD, SCLV,
SCLMAS) before saving any programs.
Problem
Cause
Solution
Torque, loss of.
1. Improper wiring.
2. No power to drive.
3. Drive failed.
4. Drive faulted.
5. Shutdown issued to drive.
1. Check wiring to the drive, as well as other system wiring.
2. Check power to drive.
3. Check drive status.
4. Check drive status.
Velocity & acceleration is
incorrect as programmed.
See Distance problem noted
above.
Power-up Program does not
execute.
220
Gem6K Series Programmer’s Guide
1.b. Refer to the instructions on page 104, or to the INFNC or
LIMFNC command descriptions.
5. Re-enable drive by sending the DRIVE1 command.
www.comoso.com
Program Debug Tools
After creating your programs, you may need to debug the programs to ensure that they
perform as expected. The Gem6K provides several debugging tools. Detailed descriptions
are provided on the following pages.
• Status Commands: Use the “Transfer” commands (e.g., TAS, TSS, TIN) to display
various controller status information. Multi-Tasking: System (TSS) and Error (TER)
status information is task specific; to check the status for a specific task, you must
prefix the status command with the task identifier (e.g., 2%TSS to check the system
status for task 2).
• Error Messages: You can enable the Gem6K to display error messages when it
detects certain programming errors as you enter them or as the program is run. When
the controller detects an error with a command, you can issue the TCMDER command to
find out which command caused the error.
• Trace mode: Trace a program as it is executing.
• Single-Step mode: Step through the program one command at a time.
• Break Points: Establish locations in your program, where command processing will
halt and a message will be transmitted to the PC.
• Simulate Programmable I/O Activation: You can set the desired state of the
Gem6K’s inputs and outputs via software commands.
• Simulate Analog Input Activation: Without an actual voltage present, you can
simulate a specific voltage on the Gem6K’s analog input channels using the ANIEN
command.
• Motion Planner’s Panel Gallery: Motion Planner’s Panel Gallery provides an
assortment of test panels you can use to verify various system I/O and operating
parameters.
Index
221
www.comoso.com
Status Commands
Status commands are provided to assist your diagnostic efforts. These commands display
status information such as, axis-specific conditions, general system conditions, error
conditions, etc.
Checking Specific Setup Parameters
One way to check the conditions that are established with a specific setup command is to
simply type in the command name without parameters. For example, type “ERES” to check
the encoder resolution setting; the response would look something like: *ERES4ØØØ.
Refer to page 64 for a list of most setup parameters and their respective commands.
TIP: To send a status
command to the Gem6K
product during program
execution, prefix the
command with an “!” (e.g.,
!TASF).
Below is a list of the status commands that are commonly used for diagnostics. Additional
status commands are available for checking other elements of your application (see List of All
Status Commands below). For more information on each status command, refer to the
respective command description in the Gem6K Series Command Reference.
SPECIAL NOTATIONS
*
The command has a binary report version (just leave the “F” off when you type
it in—e.g., TAS). This is used more by experienced Gem6K programmers.
Using the binary report command, you can check the status of one particular
bit (e.g., The TAS.1 command reports “1” if motor is moving or “Ø” if it is not
moving.). In the binary report the bits are numbered left to right, 1 through n.
A “1” in the binary report correlates to a “YES” in the full text report, and a “Ø”
correlates to a “NO” in the full text report.
† The command has an assignment/comparison operator that uses the bit status
for conditional expressions and variable assignments. For example, the
WAIT(1AS.1=bØ) command pauses program execution until status bit
number 1 (1AS.1) reports a binary zero value (indicates that the motor is notmoving). See page 7 and page 25 for more information on using assignment
and comparison operators in conditional expressions and variable
assignments.
222
Gem6K Series Programmer’s Guide
www.comoso.com
TASF
Reports axis-specific conditions.
* (TAS)
† (AS)
1. Axis is in motion (commanded)
17. Positive-direction software limit (LSPOS)
encountered
2. Direction is negative
18. Negative-direction software limit (LSNEG)
encountered
3. Accelerating (n/a to deceleration)
19. Within Deadband (steppers) Within deadband
(EPMDB) — steppers only
4. At velocity
20. RESERVED In position (COMEXP)
5. Home Successful (HOM)
21. RESERVED
6. In absolute positioning mode (MA)
22. RESERVED
7. In continuous positioning mode (MC)
23. Position error limit is exceeded (SMPER) (servos)
8. In Jog Mode (JOG)
24. Load is within Target Zone (STRGTD & STRGTV)
(servos)
9. In Joystick Mode (JOY)
25. Target Zone timeout occurred (STRGTT) (servos)
10. RESERVEDIn Encoder Step Mode (ENC) —
26. Motion suspended, pending GOWHEN
steppers
11. Position Maintenance Mode (steppers)Position
Maintenance on (EPM) — steppers
27. RESERVED
12. Stall detected (ESTALL) (steppers)
28. Registration move occurred since last GO
13. Drive shutdown occurred
29. GOWHEN Error: Input or position true before Go
14. Drive fault occurred
30. Pre-emptive (OTF) GO or Registration profile not
possible
15. Positive-direction hardware limit hit
31. Compiled GOBUF profile is executing
16. Negative-direction hardware limit hit
32. RESERVED
Index
223
www.comoso.com
TASXF
Reports extended axis-specific conditions.
1. Motor Fault
2. Low voltage Fault
3. Drive over-temperature Fault
4. RESERVED
5. Resolver failure detected (servos)
6.RESERVED
7. Motor configuration error
8. RESERVED
9. Velocity error limit (SMVER) (servos)
10. Bridge fault
11. Bridge temperature fault
(servos)
12. Over-voltage (servos)
13-16. RESERVED
17. Stall detected (ESTALL or DSTALL) (steppers)
18. Override mode invoked
19. Bridge in foldback mode (servos)
20. Power dissipation circuit active (not applicable on some servos)
21. Bad Hall state (servos)
22. Unrecognized hardware (consult factory)
23.User fault input active
24. Keep alive active
25. Power dissipation circuit fault (not applicable on some servos)
26. RESERVED
27. RESERVED
28. Motor configuration warning
29. ORES failure
30. Motor thermal model fault (servos)
31. Command torque/force at limit (TTRQ=DMTLIM) (servos)
32. RESERVED
224
Gem6K Series Programmer’s Guide
* (TASX)
† (ASX)
www.comoso.com
TSTAT
Reports general system setup and current conditions.
Sample response for the Gem6K:
*Gem6K revision: 92-XXXXXX-01-6.0 Gem6K GV6K-L3E D1.72 F1.3
*Ethernet address: xxxxxxxxxx; IP address: 192.168.10.30
*Power-up program assignment (STARTP): SETUP
*ENABLE input OK: Yes
*Drive status (DRIVE): 0
*Drive resolution (DRES): 25000
*Encoder resolution (ERES): 4000
*Hard Limit enable: LH3
*Soft Limit enable: LS0
*Current Motion Attributes:
* Scaling enabled (SCALE1): 0
* Acceleration scaler (SCLA): 4000
* Distance scaler (SCLD): 1
* Velocity scaler (SCLV): 4000
* Commanded position (TPC): +0
* A10.0000
* AA10.0000
* AD10.0000
* ADA10.0000
* V1.0000
* D+4000
*I/O Status:
* Onboard limit inputs:
*
Hardware state (TLIM):
000
* Expansion I/O bricks: See TIO response
*Axis Status (see TASF for full text report):
* Axis #1 (1TAS): 0010_0000_0000_1000_0000_0001_0000_0000
*System Status (This is task 0 status if using multi-tasking.):
*0 Programs Defined; Scale Enable 0
*
System status (TSSF):
1000_1100_0000_0000_0000_0100_0000_0000
Index
225
www.comoso.com
TSSF
Reports current system conditions.
* (TSS)
† (SS)
Multi-tasking: Each task has its own system status; therefore, to check the
system status for a specific task, prefix the TSSF command (e.g., 2%TSSF).
1. System is ready
2. RESERVED
3. Executing a Program
4. Last command was immediate
17. Loading Thumbwheel Data (TW operator)
18. In External Program Select Mode (INSELP)
19. Dwell in Progress (T command)
20. Waiting for RP240 Data (DREAD or DREADF)
5. In ASCII Mode
6. In Echo Mode (ECHO)
7. Defining a Program (DEF)
8. In Trace Mode (TRACE, TRACEP)
21. RP240 Connected
22. Non-volatile Memory Error
23. Gathering servo data (servos)
24. Suspend on Swap (multi-tasking)
9. In Step Mode (STEP)
10. FS Translate Mode
11. Command error (check with TCMDER)
12. Break Point Active (BP)
25. RESERVED
26. Suspended on COM1 (multi-tasking)
27. Suspended on COM2 (multi-tasking)
28. Program Pending (multi-tasking)
13. Pause Active (PS or pause input)
14. Wait Active (WAIT)
15. Monitoring On Conditions (ONCOND)
16. Waiting for Data (READ)
29. Compiled memory partition is 75% full
30. Compiled memory partition is 100% full
31. Compile operation (PCOMP) failed
32. EXE Failed (multi-tasking)
TINOF
Reports the status of the ENABLE input.
* (TINO)
† (INO)
1-5. RESERVED
6. ENABLE input OK (motion not inhibited
7-8. RESERVED
TFSF
226
Reports Following Mode conditions (details on page 170). * (TFS)
† (FS)
1. Follower in ratio move
2. Current ratio is negative
3. Follower is changing ratio
4. Follower at ratio (constant non-zero ratio)
17. Master position prediction mode enabled (FPPEN)
18. Master position filtering mode enabled (FFILT)
19. Performing FRC move
20. RESERVED
5. FOLMAS Active
6. Following Mode enabled (FOLEN)
7. Master is moving
8. Master direction is negative
21. Master window given
22. Inside master window
23. OK to do a geared advance (FGADV) move
24. Geared advance (FGADV) move is underway
9. OK to Shift
10. Shifting now
11. FSHFC-based shift move is in progress
12. Shift direction is negative
25. RESERVED
26. Present Following move is limited by FMAXA or FMAXV.
27. RESERVED
28. RESERVED
13. Master cycle trigger input is pending
14. Mas cycle length (FMCLEN) given
15. Master cycle position is negative
16. Master cycle number is > 0
29. RESERVED
30. RESERVED
31. RESERVED
32. RESERVED
Gem6K Series Programmer’s Guide
www.comoso.com
TERF
Reports error conditions. **
* (TER)
† (ER)
Multi-tasking: Each task has its own error status; therefore, to check the
error status for a specific task, prefix the TERF command (e.g., 2%TErF).
1. Stall detected. 1st: Enable Stall Detection (ESTALL or DSTALL).
2. Hardware end-of-travel limit encountered. 1st: Enable hard limits (LH).
3. Software end-of-travel limit encountered. 1st: Enable hard limits (LH).
4. Drive Fault is active.
5. RESERVED
6. A programmable input, defined as a “kill” input, is active.
7. A programmable input, defined as a “user fault” input, is active.
8. A programmable input, defined as a “stop” input, is active.
9. ENABLE input not grounded.
10. Pre-emptive (OTF) GO or Registration profile not possible.
11. Target Zone settling timeout period (STRGTT) is exceeded. — servo only
12. Max. position error (SMPER value) is exceeded. — servo only
13. RESERVED
14. GOWHEN condition already true.
15. RESERVED
16. Bad command detected (use TCMDER to identify the bad command).
17. RESERVED
18. Expansion I/O brick is disconnected or has lost power.
19-22. RESERVED
23. Client connect error
24. Client polling error
25-32. RESERVED
** The error condition will not be reported until you enable the respective error-checking bit with the ERROR
command (for details, see page 30 or the ERROR command description). NOTE that when the errorchecking bit is enabled and the error occurs, the controller will branch to the “error” program that you
assigned with the ERRORP command.
Other status commands commonly used for diagnostics:
TDIR........ Identifies the name and number of all programs residing in the Gem6K product's memory. Also
reports percent of available memory for programs and compiled path segments.
TCMDER.... Identifies the bad command that caused the error prompt (?). (see page 232 for details)
TEX .......... Execution status (and line of code) of the current program in progress. Task specific.
TIN .......... Binary report of all programmable and trigger inputs (“1” = active, “Ø“ = inactive). INFNC also
reports the state and programmed function of each input. (see page 91 for bit assignments)
TOUT........ Binary report of all programmable and auxiliary outputs (“1” = active, “Ø“ = inactive). OUTFNC
also reports the state and programmed function of each output. (see page 91 for bit
assignments)
TLIM........ Binary report of all limit inputs (“1” = active, “Ø“ = inactive). LIMFNC also reports the state and
programmed function of each limit input. (see page 91 for bit assignments)
TIO .......... Reports current contents on all expansion I/O bricks connected to the Gem6K. Includes current
state and function of the digital inputs and outputs, as well as voltage of analog inputs.
TPER........ (servo axes) Reports the difference between the commanded position and the actual position
as measure by the feedback device.
TPC .......... Current commanded position.
TPE .......... Current position of the encoder.
TFB .......... (servo axes) Current position of the feedback device selected with the last SFB command.
TPMAS...... Current position of the Following master
TPSLV...... Current position of the Following slave
TNMCY...... Current master cycle number.
TNT .......... Reports the current Ethernet conditions (Ethernet enabled/disabled, IP address, Ethernet MAC
address, Ethernet cable connected/disconnected).
Index
227
www.comoso.com
List of All Status
Commands
SPECIAL NOTATIONS
*
The command responds with a binary report. This is used more by experienced Gem6K
programmers. Using the bit select operator (.), you can check the status of one particular bit
(e.g., The TAS.1 command reports “1” if the motor is moving or “Ø” if it is not moving.). In the
binary report, the bits are numbered left to right, 1 through n. A “1” in the binary report
correlates to a “YES” in the full text report, and a “Ø” correlates to a “NO” in the full text report.
∆ The command has a full-text report version (just add an “F” when you type it in—e.g., TASF).
This makes it easier to check status information without having to look up the purpose of each
status bit. (see full-text descriptions, beginning on page 222)
† The command has an assignment/comparison operator that uses the bit status for conditional
expressions and variable assignments. For example, the WAIT(1AS.1=bØ) pauses progress
execution until the status bit number 1 (1AS.1) reports a binary zero value (indicates that the
axis is not-moving). See page 7 and page 25 for more information on using assignment and
comparison operators in conditional expressions and variable assignments.
COMMAND STATUS SUBJECT
TANI ...............Voltage of ANI analog inputs on EVM32 bricks (servo products with ANI option) †
TANO ...............Voltage of ANO analog inputs on EVM32 bricks †
TAS .................Binary Report of Axis Status * ∆ †
TASX .............Binary Report of Axis Status – extended * ∆ †
TCMDER...........Command Error (view command that caused the error prompt)
TDIR ...............Program Directory and Available Memory
TDPTR.............Data Pointer Status †
TER .................Error Status * ∆ †
TEX .................Program Execution Status †
TFB .................Position of Selected Feedback Devices †
TFS .................Binary Report of Following Status * ∆ †
TGAIN.............Current Value of Active Servo Gains
TIN .................Binary Report of Status of Programmable Inputs * †
TINO ...............Status of the ENABLE input (bit #6) * ∆ †
TIO .................Report of all I/O on expansion I/O bricks
TLABEL...........Defined Labels (names of)
TLIM ...............Binary Report of Hardware Status of All Limit Inputs †
TMEM ...............Memory Usage (partition and available memory)
TNMCY.............Master Cycle Number †
TNT .................Current Ethernet Conditions, including the TNTMAC report
TNTMAC...........Ethernet Address
TOUT ...............Binary Report of Status of Programmable Outputs * †
TPANI.............Position of ANI Inputs †
TPC .................Commanded Position †
TPCC ...............Captured Commanded Position †
TPCE ...............Captured Encoder Position †
TPCME.............Captured Master Encoder Position †
TPCMS.............Captured Master Cycle Position †
TPE .................Position of Encoder †
TPER ...............Position Error †
TPMAS.............Position of Master Axis †
TPME ...............Position of Master Encoder †
TPROG .............Contents of a Program
TPSHF .............Net Position Shift †
TPSLV .............Current Commanded Position of the Slave †
TREV ...............Firmware Revision Level
TSC .................Binary Report of Controller Status * ∆ †
TSCAN .............Scan Time of Last PLC Program
TSGSET...........Servo Gain Sets
TSEG ...............Number of Free Segment Buffers †
TSS .................Binary Report of System Status * ∆ †
TSTAT .............Statistics
TSTLT .............Settling Time
TSWAP .............Identify Currently Active Tasks (in multi-tasking) * †
TTASK .............Task Number of the program that executes this command †
TTIM ...............Time Value †
TTRIG .............Status of “Trigger Interrupt” Activation * †
TUS .................User Status * †
TVEL ...............Current Commanded Velocity †
TVELA .............Current Actual Velocity †
TVMAS .............Current Velocity of the Master Axis †
228
Gem6K Series Programmer’s Guide
www.comoso.com
Error Messages
Depending on the error level setting (set with the ERRLVL command), when a programming error is created, the Gem6K will
respond with an error message and/or an error prompt. A list of all possible error messages is provided in a table below. The
default error prompt is a question mark (?), but you can change it with the ERRBAD command if you wish.
At error level 4 (ERRLVL4—the factory default setting) the Gem6K responds with both the error message and the error prompt.
At error level 3 (ERRLVL3), the Gem6K responds with only the error prompt.
Error Response
Possible Cause
ACCESS DENIED
Program security feature enabled, but program access input (INFNCi-Q) not
activated.
ALREADY DEFINED FOR THUMBWHEELS
Attempting to assign an I/O function to an I/O that is already defined as a
thumbwheel I/O.
ALTERNATIVE TASK NOT ALLOWED
Attempting to execute a LOCK command directed to another task.
AXIS NOT READY
Compiled Profile path compilation error.
COMMAND NOT IMPLEMENTED
Command is not applicable to the Gem6K Series product.
COMMAND NOT ALLOWED IN PROGRAM
Command is not allowed inside a program definition (between DEF and END).
COMMAND/DRIVE MISMATCH
The command (or ≥ one field in the command) is not appropriate to the
AXSDEF configuration (e.g., attempting to execute a servo tuning command on
a stepper axis)
ERROR: MOTION ENDS IN NON-ZERO Compiled Motion: The last GOBUF segment within a PLOOP/PLN loop does not
VELOCITY - AXIS N
end at zero velocity, or there is no final GOBUF segment placed outside the loop.
FOLMAS NOT SPECIFIED
No FOLMAS for the axis is currently specified. It will occur if FMCNEW, FSHFC, or
FSHFD commands are executed and no FOLMASØ command was executed, or
FOLMAS0 was executed.
INCORRECT AXIS
Axis specified is incorrect.
INCORRECT BRICK NUMBER
Attempted to execute a command that addresses an I/O brick that is not
connected to your Gem6K.
INCORRECT DATA
Incorrect command syntax.
Following: Velocity (V), acceleration (A) or deceleration (AD) command is zero
(used by FSHFC & FSHFD).
INPUT(S) NOT DEFINED AS
JOYSTICK INPUT
Attempted to execute JOYCDB, JOYCTR, JOYEDB, or JOYZ before executing
JOYAXH or JOYAXL to assign the analog input to an axis.
INSUFFICIENT MEMORY
Not enough memory for the user program or compiled profile segments. This
may be remedied by reallocating memory (see MEMORY command description).
INVALID COMMAND
Command is invalid because of existing conditions
Index
229
www.comoso.com
Programming Error Messages
(continued)
Error Response
Possible Cause
INVALID CONDITIONS FOR COMMAND
System not ready for command (e.g., LN command issued before the L
command).
Following (these conditions can cause an error during Following):
• The FOLMD value is too small to achieve the preset distance and still
remain within the FOLRN/FOLRD ratio.
• A phase shift cannot be performed:
FSHFD
Error if already shifting or performing other time based move.
FSHFC .... Error if currently executing a FSHFD move, or if currently
executing another FSHFC move in the opposite direction.
• The FOLEN1 command was given while a profile was suspended by a
GOWHEN.
INVALID CONDITIONS FOR
S_CURVE ACCELERATION—FIELD n
Average (AA) acceleration or deceleration command (e.g., AA, ADA, HOMAA,
HOMADA, etc.) with a range that violates the equation ½A ≤ AA ≤ A (A is the
max. accel or decel command—e.g., A, AD, HOMA, HOMAD, etc.)
INVALID DATA
Data for a command is out of range.
Following (these conditions can cause an error during Following):
• The parameter supplied with the command is valid.
FFILT
Error if: smooth number is not 0-4
FMCLEN .. Error if: master steps > 999999999 or negative
FMCP....... Error if: master steps > 999999999 or < -999999999
FOLMD .... Error if: master steps > 999999999 or negative
FOLRD .... Error if: master steps > 999999999 or negative
FOLRN .... Error if: follower steps > 999999999 or negative
FSHFC .... Error if: number is not 0-3
FSHFD .... Error if: follower steps > 999999999 or < -999999999
GOWHEN .. Error if: position > 999999999 or < -999999999
WAIT....... Error if: position > 999999999 or < -999999999
• Error if a GO command is given in the preset positioning mode (MCØ) and:
FOLRN = zero
FOLMD = zero, or too small
(see Following chapter on page 177)
INVALID FOLMAS SPECIFIED
Following: An illegal master was specified in FOLMAS. A follower may never
use its own commanded position or feedback source as its master.
INVALID RATIO
Following: Error if the FOLRN:FOLRD ratio after scaling is > 127 when a GO is
executed
INVALID TASK IDENTIFIER
Attempting to launch a PEXE or EXE command into the supervisor task (task 0).
LABEL ALREADY DEFINED
Defining a program or label with an existing program name or label name
MASTER SLAVE DISTANCE MISMATCH
Attempting a preset Following move with a FOLMD value that is too small
MAXIMUM COMMAND LENGTH EXCEEDED
Command exceeds the maximum number of characters
MAXIMUM COUNTS PER SECOND
EXCEEDED
Velocity value is greater than 1,600,000 counts/sec
MOTION IN PROGRESS
Attempting to execute a command not allowed during motion (see Restricted
Commands During Motion on page 17.)
Following: The FOLEN1 command was given while that follower was moving in
a non-Following mode.
230
Gem6K Series Programmer’s Guide
www.comoso.com
Programming Error Messages
(continued)
Error Response
Possible Cause
NEST LEVEL TOO DEEP
IFs, REPEATs, WHILEs, or GOSUBs nested greater than 16 levels (for each type)
NO MOTION IN PROGRESS
Attempting to execute a command that requires motion, but motion is not in
progress
NO PATH SEGMENTS DEFINED
Compiled Profile compilation error
NO PROGRAM BEING DEFINED
END command issued before a DEF command
NOT ALLOWED IF SFBØ
Changes to tuning commands and SMPER are not allowed if SFBØ is selected
NOT ALLOWED IN PATH
Compiled Profile path compilation error
NOT DEFINING A PATH
Executing a compiled profile command while not in a path
NOT VALID DURING FOLLOWING
MOTION
A GO command was given while moving in the Following mode (FOLEN1) and
while in the preset positioning mode (MCØ).
NOT VALID DURING RAMP
A GO command was given while moving in a Following ramp and while in the
continuous positioning mode (MC1). Following status (FS) bit #3 will be set to 1.
A FOLEN command was given during one of these conditions:
• During a shift (FSHFC or FSHFD)
• During a change in ratio (FOLRN/FOLRD)
• During deceleration to a stop
OUTPUT USED AS OUTFNC
Attempted to change an output that is not a “general purpose” (OUTFNCi-A)
output (see page 107)
PATH ALREADY MOVING
Compiled Profile compilation error
PATH NOT COMPILED
Attempting to execute a individual profile that has not been compiled
STRING ALREADY DEFINED
A string (program name or label) with the specified name already exists
STRING IS A COMMAND
Defining a program or label that is a command or a variant of a command
UNDEFINED LABEL
Command issued to product is not a command or program name
WARNING: POINTER HAS WRAPPED
AROUND TO DATA POINT 1
During the process of writing data (DATTCH) or recalling data (DAT), the pointer
reached the last data element in the program and automatically wrapped
around to the first datum in the program
WARNING: ENABLE INPUT INACTIVE
ENABLE input is no longer connected to ground (GND)
WARNING: DEFINED WITH ANOTHER
TW/PLC
Duplicate I/O in multiple thumbwheel definitions
Index
231
www.comoso.com
Identifying Bad
Commands
To facilitate program debugging, the Transfer Command Error (TCMDER) command allows
you to display the first command that the controller detects as an error. This is especially
useful if you receive an error message when running or downloading a program, because it
catches and remembers the command that caused the error.
Using Motion Planner:
If you are typing the command in a live terminal emulator session, the controller will
detect the bad command and respond with an error message, followed by the ERRBAD
error prompt (?). If the bad command was detected on download, the bad command
is reported automatically (see example below).
NOTE: If you are not using Motion Planner, you’ll have to type in the TCMDER
command at the error prompt to display the bad command.
Once a command error has occurred, the command and its fields are stored and system status
bit #11 (reported in the TSSF, TSS and SS commands) is set to 1, and error status bit #16
(reported in the TERF, TER and ER commands) is set to 1. The status bit remains set until the
TCMDER command is issued.
Example Error
Scenario
1. In Motion Planner’s program editor, create and save a program with a programming error:
DEL badprg
DEF badprg
MA1
A25
AD11
V5
VAR1=0
GO1
IF(VAR1<)16
VAR1=VAR1+1
NIF
END
;
;
;
;
;
;
;
;
;
;
;
;
Delete a program before defining and downloading
Begin definition of program called badprg
Select the absolute preset positioning mode
Set acceleration
Set deceleration
Set velocity
Set variable #1 equal to zero
Initiate move on axis
MISTYPED IF STATEMENT - should be typed as "IF(VAR1<16)"
If variable #1 is < 16, increment the counter by 1
End IF statement
End programming of program called badprg
2. Using Motion Planner’s terminal emulator, download the program to the Gem6K Series
product. Notice that an error response identifies the bad command as an “INCORRECT
DATA” item and displays it:
> *NO ERRORS
*INCORRECT DATA
> *IF(VAR1<)16
>
Trace Mode
You can use the Trace mode to debug a program. The Trace mode allows you to track,
command-by-command, the entire program as it runs. The Gem6K will display all of the
commands as they are executed. NOTE: Program tracing is also available on the RP240
display (see page 127).
The example below demonstrates the Trace mode.
Step 1
Create a program called prog1:
DEF prog1
A10
AD10
V5
L3
GOSUB prog3
LN
END
232
Gem6K Series Programmer’s Guide
;
;
;
;
;
;
;
;
Begin definition of program prog1
Acceleration is 10
Deceleration is 10
Velocity is 5
Loop 3 times
Gosub to program #3 (prog3)
End the loop
End definition of program prog1
www.comoso.com
Step 2
Create a program prog3:
DEF prog3
D50000
GO1
END
Step 3
Begin definition of program prog3
Sets the distance to 50,000
Initiates motion
End definition of program prog3
Enable the Trace Mode:
TRACE1
Step 4
;
;
;
;
; Enables the Trace mode
Execute the program prog1: (each command in the program is displayed as it is executed)
EOT13,10,0
RUN prog1
; Set End-of-Transmission characters to <cr>,<lf>
; Run program prog1
The response will be:
*PROGRAM=PROG1
*PROGRAM=PROG1
*PROGRAM=PROG1
*PROGRAM=PROG1
*PROGRAM=PROG1
*PROGRAM=PROG3
*PROGRAM=PROG3
*PROGRAM=PROG3
*PROGRAM=PROG1
*PROGRAM=PROG1
*PROGRAM=PROG3
*PROGRAM=PROG3
*PROGRAM=PROG3
*PROGRAM=PROG1
*PROGRAM=PROG1
*PROGRAM=PROG3
*PROGRAM=PROG3
*PROGRAM=PROG3
*PROGRAM=PROG1
*PROGRAM=PROG1
COMMAND=A10.0000
COMMAND=AD10.0000
COMMAND=V5.0000
COMMAND=L3
COMMAND=GOSUB PROG3 LOOP COUNT=1
COMMAND=D50000 LOOP COUNT=1
COMMAND=GO1 LOOP COUNT=1
COMMAND=END LOOP COUNT=1
COMMAND=LN LOOP COUNT=1
COMMAND=GOSUB PROG3 LOOP COUNT=2
COMMAND=D50000 LOOP COUNT=2
COMMAND=GO1 LOOP COUNT=2
COMMAND=END LOOP COUNT=2
COMMAND=LN LOOP COUNT=2
COMMAND=GOSUB PROG3 LOOP COUNT=3
COMMAND=D50000 LOOP COUNT=3
COMMAND=GO1 LOOP COUNT=3
COMMAND=END LOOP COUNT=3
COMMAND=LN LOOP COUNT=3
COMMAND=END
The format for the Trace mode display is:
Program Name ... Command
Program Name ... Command
Program Name ... Command
Step 5
Loop Count
Repeat Count
While Count
or
or
Exit the Trace Mode.
TRACE0
Tracing Program
Flow
...
...
...
; Disables the Trace mode
Using the TRACEP command, you can monitor the entry and exit of programs and their
associated nest levels.
For example, let’s assume these four programs are defined:
DEF PICK1
GOSUB PICK2
GOTO PICK3
END
DEF PICK2
GOSUB PICK4
END
DEF PICK3
END
DEF PICK 4
END
Index
233
www.comoso.com
Now we’ll enable the TRACEP mode and launch the calling program (PICK1) to start tracing
the program flow:
>TRACEP1
>PICK1
*INITIATE
*INITIATE
*INITIATE
*END:
*END:
*INITIATE
*END:
>TRACEP0
PROGRAM:
PROGRAM:
PROGRAM:
PROGRAM:
PICK1
PICK2
PICK4
PROGRAM
PROGRAM
PICK3
PROGRAM
NEST=1
NEST=2
NEST=3
NOW: PICK2
NEST=2
NOW: PICK1
NEST=1
NEST=1
EXECUTION TERMINATED
Single-Step Mode
The Single-Step mode allows you to execute one command at a time. Use the STEP
command to enable Single-Step mode. To execute a command, you must use the !# sign. By
entering a !# followed by a delimiter, you will execute the next command in the sequence. If
you follow the !# sign with a number (n) and a delimiter, you will execute the next n
commands. The Single-Step mode is demonstrated below (using the programs from the Trace
mode above).
Step 1
Enable the Single-Step Mode:
STEP1
Step 2
; Enables Single Step Mode
Enable the Trace Mode and begin execution of program prog1:
TRACE1
RUN prog1
Step 3
; Enables the Trace mode
; Run program called prog1
Execute one command at a time by using the !# command:
!#
; Executes one command
The response will be:
*PROGRAM=PROG1
Step 4
COMMAND=A10.0000
To execute more than one command at a time, follow the !# sign with the number of
commands you want executed:
!#3
; Executes three commands
The response will be:
*PROGRAM=PROG1
*PROGRAM=PROG1
*PROGRAM=PROG1
COMMAND=AD10.0000
COMMAND=V5.0000
COMMAND=L3
To complete the sequence, use the # sign until all the commands are completed (!#16 would
complete the example).
Step 5
To exit Single-Step mode, type:
STEP0
234
; Disables Single Step Mode
Gem6K Series Programmer’s Guide
www.comoso.com
Break Points
The Break Point (BP) command allows you to establish a location in the program where
command processing will halt and a message will be transmitted to the PC. There are 32 break
points available, BP1 to BP32, all transmitting the message *BREAKPOINT NUMBER n<cr>
where n is the break point number.
After halting at a break point, command processing can be resumed by issuing an immediate
continue (!C) command.
The break point command is useful for stopping a program at specific locations in order to test
status for debugging or other purposes.
Example
DEF prog1
D50000
MA1
GO1
IF(1PC>40000)
BP1
NIF
D80000
GO1
BP2
END
RUN prog1
;
;
;
;
;
;
;
;
;
;
;
;
Begin definition of program named prog1
Set distance: 50000 units on axis 1
Absolute mode for axes 1
Initiate motion on axes 1
Compare axis 1 commanded position to 40000
If motor position is > 40000 units, set break point #1
End IF statement
Set distance: 80000 units on axis 1
Initiate motion on axes 1
Set break point #2
End program definition
Execute program prog1
In the example above, when the IF statement evaluates true, the controller will transmit the
message *BREAKPOINT NUMBER 1. A !C command must be issued before processing will
continue. Once processing has continued, the second break point command will be
encountered, and the message *BREAKPOINT NUMBER 2 will be transmitted, and processing
of commands will pause until a second !C command is received.
Simulating I/O Activation
If your application has inputs and outputs that integrate the Gem6K with other components in
your system, you can simulate the activation of these inputs and outputs so that you can run
your programs without activating the rest of your system. Thus, you can debug your program
independent of the rest of your system.
There are two commands that allow you to simulate the input and output states desired. The
INEN command controls the inputs and the OUTEN command controls the outputs.
NOTE
The INEN command has no effect on the trigger inputs when they are configured as trigger
interrupt (position latch) inputs with the INFNCi-H command.
The OUTEN command has no effect on the onboard outputs when they are configured as
output-on-position outputs with the OUTFNCi-H command.
You will generally use the INEN command to cause a specific input pattern to occur so that a
program can be run or an input condition can become true. Use the OUTEN command to
simulate the output patterns that are needed, and to prevent an external portion of your system
from being initiated by an output transition. When you execute your program, the OUTEN
command overrides the outputs and holds them in a defined state.
Index
235
www.comoso.com
Outputs
The following steps describe the use and function of the OUTEN command
Step 1
Display the state of the outputs with the TOUT command:
TOUT
; Displays the state of the outputs
The response will be:
*TOUT0000_000
Display the function of the outputs with the OUTFNC command:
OUTFNC
; Displays the state of the outputs
The response will be:
*OUTFNC1-A
*OUTFNC2-A
*OUTFNC3-A
*OUTFNC4-A
*OUTFNC5-A
*OUTFNC6-A
*OUTFNC7-A
Step 2
PROGRAMMABLE
PROGRAMMABLE
PROGRAMMABLE
PROGRAMMABLE
PROGRAMMABLE
PROGRAMMABLE
FAULT OUTPUT
OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT - STATUS
STATUS
STATUS
STATUS
STATUS
STATUS
STATUS
OFF
OFF
OFF
OFF
OFF
OFF
OFF
Disable outputs 1 - 4, leave them in the ON state.
OUTEN1111
OUTFNC
; Disable outputs 1-4, leave them in ON state
; Displays the state of the outputs
The response will be:
*OUTFNC1-A
*OUTFNC2-A
*OUTFNC3-A
*OUTFNC4-A
*OUTFNC5-A
*OUTFNC6-A
*OUTFNC7-A
Step 3
PROGRAMMABLE
PROGRAMMABLE
PROGRAMMABLE
PROGRAMMABLE
PROGRAMMABLE
PROGRAMMABLE
FAULT OUTPUT
OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT - STATUS
STATUS
STATUS
STATUS
STATUS
STATUS
STATUS
OFF
DISABLED
DISABLED
DISABLED
DISABLED
OFF
OFF
ON
ON
ON
ON
Change the output state using the OUT command. The status of all outputs, including auxiliary
outputs, is displayed. The output bit pattern varies by product. To determine the bit pattern for
your product, refer to the OUTEN command description.
OUT1010
; Activates outputs 1 and 3, deactivates outputs 2 and 4
Display the state of the outputs with the OUTFNC command.
OUTFNC
; Displays the state of the outputs
The response will be:
*OUTFNC1-A
*OUTFNC2-A
*OUTFNC3-A
*OUTFNC4-A
*OUTFNC5-A
*OUTFNC6-A
*OUTFNC7-A
PROGRAMMABLE
PROGRAMMABLE
PROGRAMMABLE
PROGRAMMABLE
PROGRAMMABLE
PROGRAMMABLE
FAULT OUTPUT
OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT - STATUS
STATUS
STATUS
STATUS
STATUS
STATUS
STATUS
OFF
DISABLED
DISABLED
DISABLED
DISABLED
OFF
OFF
ON
ON
ON
ON
Notice that output 2 and output 4 have not changed state because the output (OUT) command
has no effect on disabled outputs.
Step 4
To re-enable the outputs, use the OUTEN command.
OUTENEEEE
236
Gem6K Series Programmer’s Guide
; Re-enables outputs 1-4
www.comoso.com
Inputs
The steps below describe the use and function of the INEN command. You can use it to cause
an input state to occur. The inputs will not actually be in this state but the Gem6K treats them
as if they are in the given state and will use this state to execute its program.
Step 1
This program will wait for an input state to occur and will then make a preset move:
INFNC1-A
INFNC2-A
INLVL00
DEF prog8
A100
AD100
V5
D25000
WAIT(IN=b11)
GO1
END
Step 2
; Enables the trace mode
Execute the program:
RUN prog8
Step 4
Onboard input #1 is has no function
Onboard input #2 is has no function
Set input #1 and #2 active level to low
Begin definition of program prog8
Acceleration is set to 100
Deceleration is 100
Velocity is 5
Distance is 25,000
Waits for the input state to be 11
Initiate motion
End definition of program prog8
Enable the Trace mode so that you can view the program as it is executed:
TRACE1
Step 3
;
;
;
;
;
;
;
;
;
;
;
; Runs program prog8
The program will execute until the WAIT(IN=b11) command is encountered. The program
will then pause, waiting for the input condition to be satisfied. Simulate the input state using
the INEN command. Inputs with an E value are not affected. Note that the input bit pattern
varies by product. To determine the bit pattern for your product, refer to the INEN command
description.
!INEN11
; Disables inputs 1 and 2, leaving them in the ON state
The motor will now move for 25000 steps.
Step 5
Deactivate the input simulation:
INENEE
; Re-enables inputs 1 and 2
Simulating Analog Input Channel Voltages
Without actually applying any voltage, you can test any command or function that references
the voltage on an analog input (located on an expansion I/O brick). For example,
2ANIEN.1=1.2,1.6,1.8 overrides I/O brick 2’s hardware analog input 1 through 3 as
follows: 1.2V on input 1, 1.6V on input 2, and 1.8V on input 3.
Another application for the ANIEN command may be to use it in an ERRORP program to
override the analog input voltage in response to a fault.
Motion Planner’s Panel Gallery
Motion Planner’s Panel Gallery provides diagnostic panels for testing your programs and
monitor the following:
•
•
•
•
I/O (programmable I/O, analog I/O, limits)
Motion (motor and feedback device position, velocity)
Status (axis, system, interrupt, user-defined, Following)
Terminal (direct communication with the product, to check for error messages, etc.)
Index
237
www.comoso.com
Technical Support
For solutions to your questions about implementing Gem6K product software features, first
look in this manual. Other aspects of the product (command descriptions, hardware specs, I/O
connections, graphical user interfaces, etc.) are discussed in the respective manuals listed in
Reference Documentation on page ii.
If you cannot find the answer in this documentation, contact your local Automation
Technology Center (ATC) or distributor for assistance.
If you need to talk to our in-house application engineers, please contact us at the numbers
listed on the inside cover of this manual. (The phone numbers are also provided when you
issue the HELP command to the Gem6K.)
Operating System Upgrades
You may obtain an upgraded Gem6K operating system from our web site at
http://www.compumotor.com. Instructions for downloading and upgrading the operating
system are provided on the web page.
Product Return Procedure
If you must return your Gem6K Series product to affect repairs or upgrades, use this
procedure:
Step 1
Get the serial number and the model number of the defective unit, and a purchase order number
to cover repair costs in the event the unit is determined by the manufacturers to be out of
warranty.
Step 2
Before you return the unit, have someone from your organization with a technical
understanding of the Gem6K Series product and its application include answers to the
following questions:
•
•
•
•
•
•
•
•
•
•
Step 3
238
What is the extent of the failure/reason for return?
How long did it operate?
Did any other items fail at the same time?
What was happening when the unit failed (e.g., installing the unit, cycling power,
starting other equipment, etc.)?
How was the product configured (in detail)?
What, if any, cables were modified and how?
With what equipment is the unit interfaced?
What was the application?
What was the system environment (temperature, enclosure, spacing, unit orientation,
contaminants, etc.)?
What upgrades, if any, are required (hardware, software, user guide)?
Call for a return authorization. Refer to the Technical Support phone numbers provided on the
inside cover of this manual. The support personnel will also provide shipping guidelines.
Gem6K Series Programmer’s Guide
www.comoso.com
Index
A
absolute position
absolute positioning mode 72
absolute zero position 72
establishing 72
status 72
acceleration
change on the fly 71, 155
maximum (Following) 189
scaling 68
s-curve profiling 136
units of measure 71
access to RP240 functions 129
accuracy
Following, factors affecting 189
position capture 100, 159
address
Ethernet
conflict 218
multi-drop (RS-485) 60
advance, geared (Following) 180
alarm events
trigger with an input 101
analog inputs
interface 132
override voltage 237
application examples
cam profiling (using compiled
Following) 148, 152
continuous phase shift 179
packaging (using on-the-fly motion)
157
PLC 117
PLC scan mode 117
preset phase shift 180
registration 161, 162, 163
scaling setup 70
spindle (using compiled motion)
147
stamping (using compiled
Following) 151
teaching data points 112
using a joystick 116
using an RP240 116
using analog inputs 116
using programmable I/O 116
assignment & comparison operators 7
used in conditional expressions 25
assignment of master and following
170
assumptions, skills required to
implement features ii
axis moving status 223
axis scaling 67
axis status 223
extended 224
relative to Following 195
RP240 display 128
B
BCD program select input 97
before you start programming iii
binary value identifier (b) 6
binary variables (VARB) 18, 22
bit patterns, programmable I/O 91
bit select operator (.) 6, 9
bitwise operations (and, or, not, etc.)
22
Boolean operations 21
branching 23
conditional 25
unconditional 23
buffers
buffered commands
control execution of 14
executed during motion 73, 155
stored in a program 10
command 73
C
cam profiling example 148, 152
capture positions 99
carriage return, command delimiter 6
case sensitivity 6
characters
command delimiters 6
comment delimiter 6
field separators 6
limit per line 6
neutral (spaces) 6
checksum 35
closed-loop operation, steppers 84
COM ports, controlling 56
commanded position
absolute position reference 72
follower, tracking error 188
status 227
commands
buffer 73
after pause 99
after stop 98
command buffer execution
after end-of-travel limit
(COMEXL) 15
after pause/continue input
(COMEXR) 15
after stop (COMEXS) 16
continuous (COMEXC) 14
command value substitutions 7
delimiters 6
errors in programming 232
executed during motion 155
Following (list of) 198
immediate 4, 73
restricted execution during motion
17
setup command list 64
status 222
syntax 4
comment delimiter 6
communication 37
controlling multiple serial ports 56
lock port during multi-tasking 211
options 38
problems 218
RS-485 multi-drop 60
compiled motion 139
compare with on-the-fly motion
changes 145
Following profiles 142
related commands 146
sample applications 147, 148, 151,
152
conditional branching 25, 28
conditional expression examples 25
conditional go 163
conditional GO
pending trigger input 100, 166
conditional looping 25, 28
conditional statement using PMAS
184
configuration
disable drive on kill 66
drive resolution 66
encoder-based stepper setup 84
end-of-travel limits 77
Following setup 170
joystick 130
memory allocation 11
position modes 71
Index
239
www.comoso.com
programmable inputs 94
programmable outputs 105
scaling 67
setup commands, list 64
setup program 13
continous command execution mode
(COMEXC)
effect in continuous positioning
mode 73
continue
effect on Following motion 195
continue (!C) 16, 98
continue execution on pause/resume
(COMEXR) 15, 99
continue execution on stop
(COMEXS) 16, 98
continue input 99
continue key on RP240 123
continuous positioning mode 71, 73
Following 176, 191
distance calculations 192
controlling multiple serial ports 56
count source (internally generated)
172
creating programs 10
D
daisy-chaining 59
with RP240s 60
data
fields, in command syntax 5
read from serial or Ethernet port 26
read from the RP240 26
teach to variable arrays 110
deadband for stall detection 84
debounce time
position capture 99
program select input 97
programmable inputs 96
debugging tools 221
analog input voltages, simulating
237
error messages 229
I/O activation 235
identify bad commands 232
problem/cause/solution table 218
RP240 menus 127
single-step mode 234
status commands 222
trace mode 232
deceleration
change on the fly 71, 155
scaling 68
s-curve profiling 136
units of measure 71
delimiters
command 6
comment 6
detecting a stall 84
stall indicator output 108
direction, changes in compiled motion
144
distance
calculations, Following 192
compiled motion 143
240
change on the fly 71, 155
registration 159
units of measure 71
drive
fault status 224
resolution 66, 219
effect on Following 194
shutdown
LED status 220
on kill 66, 98
stall detection 66
status on RP240 129
dwells & direction changes, compiled
motion 144
E
electrical noise See installation guide
electronic I/O devices 119
electronics concepts ii
enable input
as safety feature 116
status 226
enable or disable Following 175
status 169
while moving 195
encoder
capture/counter enable (steppers) 85
failure detection
status 224
feedback for steppers 84
position
RP240 display 128
resolution 84, 219
setup example
steppers 84
Z-channel 79
end-of-move settling 89
end-of-travel limits See limits, end-oftravel
error
clearing 32
error handling 30
related to safety 116
error message
Following specific 197
error messages 229
Following 188
on-the-fly motion errors 156
program, assignment 31
status 227
Ethernet 39
example programs ii
executing programs see program,
execution options
expansion I/O 93
commanded position 178
Following error 188
conditional go 163
definition of 170
distance
scaling 174
motor/drive accuracy 190
move profiles 175
ratio to master 174
status 169
resolution 190
scaling 174
shift See shift
following
distance
move calculations 192
Following 167
cam profiling example 148, 152
commands, list of 198
compiled Following profiles 142
conditions used in conditional
expressions 27
distance
scaling 69
enable or disable 175
status 169
while moving 195
error 188
geared advance 180
master cycle concept 182
maximum acceleration (steppers)
189
maximum velocity (steppers) 189
performance considerations 186
prerequisites to Following motion
170
ratio Following introduction 168
set-up parameters 170
status 169, 226
technical considerations 186
virtual master 172
G
geared advance (Following) 180
general purpose input function 96
general purpose output function 107
global command identifier (@) 6
GOSUB 23
GOTO 23
GOWHEN 163
cleared by stop or kill 194
error condition 227
using PMAS 184
usng PMAS 195
via trigger input 100, 166
F
H
fault output 108
field separator 6
Filter Adjustments 87
filtering, master position See master,
master position filtering
follower
hard limit See limits, end-of-travel
help (tech support services) iii, 238
hexadecimal value identifier (h) 6, 22
homing
home See limits, home
status 223
Gem6K Series Programmer’s Guide
www.comoso.com
zeroing the absolute position 79
host computer operation 133
I
I/O activation (simulation) 235
I/O device interface 118
IF 25
using PMAS 184
usng PMAS 195
immediate commands 4, 73
not stored in programs 10
immediate data read from RP240 27
immediate stop 16, 73
in position, output function 107
incremental positioning mode 72
inputs
analog 132
application example 117
enable 116
status 226
encoder See encoder
end-of-travel limits 73, 77, 116
home limits 79
joystick 130
PLC 119
programmable 90, 118
alarm event 101
bit pattern 91
debounce time 96
end-of-travel limits 104
function assignments 94, 105
functions (INFNC), effect on
system performance 35
functions (LIMFNC), effect on
system performance 35
general purpose function 96
home limits 104
jogging 101
joystick 102
kill 73, 98
one-to-one program select 103
operand (IN) 25
pause/continue 99
effect on command buffer 15
polarity 96
program security 14, 104
program select 97
simulating activation 235
status 95
status on RP240 128
stop 16, 73, 98
update rate 90
user fault 99, 116
stop 16
thumbwheel 119
triggers
debounce time 96
position capture 99
programmed functions (TRGFN)
100
update rate 90
virtual inputs 94
interface options 116
interrupts
program (ON conditions) 29
J
jerk (acceleration), reducing 136
jogging
input functions 101
RP240 jog mode 127
setup 101
status on RP240 127
joystick
application example 112, 117
interface 130
release input 102
velocity select input 102
voltage override 237
JUMP 23
K
kill
assigned input function 98
effect on drive 66, 98
effect on Following 194
effect on multi-tasking 209
kill on stall 84
L
labels ($) 23
last motion segment, compiled motion
141
LEDs 220
LEDs on RP240 123
left-to-right math 6
length, master cycle 182
limits
end-of-travel 77
as safety feature 116
effect on command buffer and
program execution 15
programmed functions 104
status 223
used as basis to activate output
108
home 79
programmed functions 104
status on RP240 128
line feed, command delimiter 6
linear interpolation
acceleration scaling 69
distance scaling 69
velocity scaling 69
linear motion parameter calculations
74
lockout distance for registration 160
logical operators 25
loops
conditional 27
unconditional 23
M
master
definition of 170
status 169
direction, status of 169
distance
move calculations 192
programming (FOLMD) 174
master cycle
counting 182
restart 183
status 182
length 182
number 184
position 182
assignment/comparison 184
initial 183
rollover 182, 195
status 184
synchronizing 185
status 169
master cycle concept 182
master input (A.K.A.) 168
master position filtering 186, 187
effect on accuracy 191
effect on position accuracy 190
status 169
master position prediction 186, 187
effect on accuracy 190
status 169
move profiles 175
moving, status of 169
ratio to follower 174
status 169
resolution 190
scaling 69, 174
velocity 186
virtual 172
mathematical operations 19
maximum position error
output to indicate exceeded 108
mechanical cam replacement 148, 152
memory
allocation 11
compiled motion 139
cleared on bad checksum 35
locking 14, 104
non-volatile 35
status 12
menus, RP240 126
messages, error 229
motion
Following motion status 170
motion control concepts ii
parameters used in conditional
expressions 25
pre-compiled profiles See compiled
motion
restrictions while in Following 195
rough 196
synchronize
conditional GOs 163
registration 159
triggered conditional GOs 163
triggered start of master cycle
163
with PMAS 185
motion parameters
linear applications 74
Motion Planner 2
communication features 38
Index
241
www.comoso.com
setup program tool 13
move completion criteria 89
moving/not moving status 107, 223
multi-drop, RS-485 60
multiple serial ports, controlling 56
multi-tasking 201
affected by kill 209
conditions used in conditional
expressions 27
performance considerations 214
programmed I/O functions 213
sharing system resources 210
task identifier (%) 6, 206, 211
task-specific resources 211
N
negative-direction end-of-travel limits
See limit, end-of-travel
Networking 39
neutral characters 6
noise, electrical See installation guide
numeric variables 18
in conditional expression 25
NWHILE 28
O
on conditions (program interrupts) 29
effect on system performance 35
one-to-one program select input 103
on-line help for Windows 2
on-line manuals ii
on-the-fly motion changes 71, 155
compare with compiled motion 145
operating system upgrades 238
operator interface
host computer operation 133
RP240 remote panel 123
operators
assignment & comparison 7
correlated to status commands
228
used in conditional expressions
25
bit select 9
bitwise 9
logic 9
math 9
relational 9
outputs
activate on position 109
output on position 109
programmable 90, 118
bit pattern 91
fault output 108
function assignments 105
functions (OUTFNC), effect on
system performance 35
general purpose function 107
limit encountered 108
max position error exceeded 108
moving/not moving 107
operand (OUT) 25
output on position 109
242
polarity 106
program in progress 107
simulating activation 235
stall indicator 108
status 106
status on RP240 128
update rate 90
update rate 90
P
partitioning memory 11
password, RP240 129
pause active, status 226
pause key on RP240 123
pause, effect on Following motion 195
pause/continue input 99
effect on motion & program
execution 15
performance, effects on 35
performance, Following 186
performance, multi-tasking 214
phase, shift 178
PLC interface 119
application example 117
PLC scan mode 120
point-to-point move 72
polarity
commanded direction
causes reversed direction 219
programmable inputs 96
programmable outputs 106
position
absolute 72
establish 72
accuracy, Following 190
analog inputs 132
capture 99
commanded 85
encoder 85
registration 159
commanded
capture 99
RP240 display 128
commanded position calculation,
Following 188
encoder 26
capture 99
RP240 display 128
error 219
exceeded max. limit
status 223
max. allowable 116
RP240 display 128
follower axis 178
incremental 72
master See master
positioning modes 71
change on the fly 71, 155
sampling period 186
effect on Following accuracy 190
status
RP240 display 128
used to active an output 109
zeroed after homing 79
positive-direction end-of-travel limits
Gem6K Series Programmer’s Guide
See limit, end-of-travel
power-up start program (STARTP) 13
clear RP240 menus 125
Following setup commands 171
will not execute 220
prediction of master position 187. See
master, master position prediction
pre-emptive GOs See on-the-fly
motion changes
preset positioning mode 72
Following 177, 191
distance calculations 193
profiling, custom 135
program
branch
conditionally 25
unconditionally 23
comments 6
creating 10
debug tools 221
editing in Motion Planner 2
error handling 30
error responses 229
examples, using ii
execution
controlling 14
from RP240 menu 127
options 13
execution status 226
interrupts 29
labels ($) 23
loop
conditionally 25
unconditionally 23
memory allocation 11
multi-tasking 202
power-up program 13
program example 10
programming guidelines 1
scan programs in PLC mode 120
security 14
setup (configuration) program 13
storage 11
program in progress 107
programmable inputs See inputs,
programmable
programmable outputs See outputs,
programmable
programming
creating programs 10
debug tools 221
debugging via RP240 127
error messages 229
error programs 34, 116
examples, using ii
executing programs
options 13
preparing to program iii
program example 10
program security 104
program selection
BCD 97
one-to-one 103
sample programs provided ii
scan programs in PLC mode 120
set-up program 13
www.comoso.com
skills required ii
storing programs 11
R
ratio of follower to master 174
status 169
reading thumbwheel data 119
reference documentation ii
registration 159
effect on Following 194
lockout distance 160
sample application 161, 162, 163
status 160
related documentation ii
relational operators 25
REPEAT 25
repeatability, Following
position sampling rate 190
sensors 191
trigger inputs 191
resetting the controller 65
via the RP240 menu 130
resolution
drive 66, 219
effect on Following 194
encoder 84, 219
follower axis 190
master axis 190
resources used by multi-tasking 210
responses, error 229
restart master cycle counting 100, 166,
183
restricted commands during motion 17
return procedure 238
revision levels from RP240 display
130
rollover of master cycle position 182,
184, 195
rough Following motion 196
RP240 123
access security 129
application example 117
COM port setup 57
connectoin verified 226
data read 26
front panel description 123
in daisy chain 60
menu structure 126
RS-485 multi-drop 60
S
safety features 116
sample programs ii
scaling 67, 71
acceleration & deceleration 68
distance 69
effect on system performance 35
follower 174
master 69, 174
velocity 68
scan programs (PLC scan mode) 120
security, program 14, 104
segment, definition of 11
serial ports, controlling 56
settling time, actual 89
set-up commands 64
set-up program 13
shift
advance 180
continuous 178
application example 179
preset 178
application example 180
status 169, 178
shift left to right (>>) 22
shift right to left (<<) 22
shutdown
LED status 220
on kill 66, 98
SIM modules 93
simulating analog input voltages 237
sine wave (internally generated) 172
single-shot registration 160, 162
single-step mode 234
RP240 menu 127
status 226
soft limit See limits, end-of-travel
space (neutral character) 6
stall deadband 84
stall detect
drive 66
encoder 84
stall detection 84
stall indicator output 108
stand-alone operation 116
start-up program (STARTP) 13
will not execute 220
statistics, controller config. & status
225
status
absolute position 72
assigned to binary variable 18
axis
extended 224
relative to Following 195
RP240 display 128
command error 232
commands
diagnostics related 222
list of 228
compiled motion 140
error conditions 227
Following 169, 226
GOWHEN 164
inputs
enable 226
RP240 display 128
LEDs 220
limits 223
RP240 display 128
master cycle number 184
master cycle position 184
motion 25, 223
OTF profiling conditions 156
outputs
RP240 display 128
pause 226
position 227, 228
captured 99
RP240 display 128
program execution 226
programmable inputs 95
programmable outputs 106
registration 160
RP240 displays 128
setup parameters 64
statistics 225
system 226
RP240 display 128
wait 226
stop
assigned input function 73
effect on Following motion 194
effect on program execution 16, 98
input (INFNCi-D) 16
stop key on RP240 123
storing programs in controller memory
11
storing variable data to arrays 110
string variables 18
subroutine, definition of 10
substitutions, command values 7
support, technical iii
swapping tasks 214
synchronizing motion
conditional GOs (GOWHEN) 163
Following (follower-to-master) 185
registration 159
trigger functions
conditional GO 166
start new master cycle 166
syntax 5
guidelines 6
system performance 35
system status 226
RP240 display 128
system update period 186
T
target zone 89
affects moving/not moving output
107
status (within zone) 223
timeout error 89
status 223
tasks See multi-tasking
teach mode 110
technical considerations for Following
186
technical support iii, 238
terminal emulation 2
testing
program debug tools 221
test panels in Motion Planner 237
test programs, Motion Planner 2
thumbwheels 119
timeout, target zone 89
status 223
trace mode 232
RP240 menu 127
status 226
trigger inputs
I/O bit pattern 91
position capture 99
Index
243
www.comoso.com
programmed
conditional GO (GOWHEN)
100, 166
restart master cycle counting
100, 166, 183
status 169
repeatability 191
trigonometric operations 20
troubleshooting 217
command problems & solutions 218
debug tools 221
enable input status 226
error messages 229
Following 196
general product condition report
225
identify bad commands 232
methods 218
status commands 222
test panels in Motion Planner 237
truncation
acceleration/deceleration 68
velocity 68
tuning
effect on Following accuracy 191
Tuning
Filter Adjustments 87
Position Mode 85
Procedures 85
244
U
unconditional branching 23
unconditional looping 23
units of measurement 67
linear motors 74
UNTIL 25
using PMAS 184
usng PMAS 195
update rate, programmable I/O 90
upgrade the Gem6K operating system
238
user fault input 99, 108
as safety feature 116
user interface options 116
user programs, memory allocation 11
V
value substitution, command fields 7
variables
binary 18, 22
in conditional expression 25
numeric 18
in conditional expression 25
teach data 110
string 18
variable arrays 110
velocity
change on the fly 71, 155
compiled motion 141
Gem6K Series Programmer’s Guide
maximum (Following) 189
scaling 68
TVEL & TVELA responses relative
to Following 195
units of measure 71
virtual inputs 94
virtual master 172
W
WAIT 25
compared to GOWHEN 165
status 226
using PMAS 184
usng PMAS 195
web site (www.compumotor.com) ii
WHILE 25, 28
using PMAS 184
usng PMAS 195
X
XON/XOFF, controlling 56
Z
Z-channel 79, 83
status 224
zero position after homing 79