CONTRACTOR’S QUALITY CONTROL
NUCLEAR DENSITY-MOISTURE TEST DATA FORM
Soil
Type
Contract ID
Job No.
Route
County
Base
Report No.
Date
Station
Location R/L – CL
Dist. Below Profile Gr.
Standard Test No.
*A – Test Number
*B – Probe Depth
*C – Density Standard Count
*D – Moisture Standard Count
*E – Moisture Correction
*F – Dry Density = DD
*G – Wet Density = WD
*H – Standard Density
*I – % Compaction = PR
*J – Minimum Density Required
*K – % Moisture
*L – Optimum Moisture
Min.
% Moisture
Specified
Max.
Retest of
Test No.
Date
Remarks:
Technician
∗
See page 2 of form for more information on testing procedures.
Rev. 04/2011
Page 2 of 2
CONTRACTOR’S QUALITY CONTROL
NUCLEAR DENSITY-MOISTURE TEST DATA FORM
A – Consecutive, by material per project
F – Record from display for current test
B – Reading on display must match probe position
G - Record from display for current test
C – Read direct from display – Daily Standard
H – Provided by Materials for current material
D – Read direct from display – Daily Standard
I – Record from display for current test
E – Record correction for current material
J – Provided in contract documents or specifications
(Reference page 3–4 Troxler Manual
K – Record from display for current test
L – Provided form Materials for current material
DAILY CHECK LIST
1.
2.
3.
4.
5.
6.
7.
8.
9.
Two different keys are needed
Wear badge
Make entry in sign out diary
Place travel papers on truck dashboard in plain view within driver’s reach (transport gauge in locked box
only)
Warm up machine 10 minutes – Set on plate with probe opposite butt plate
Take standard count – record standard counts in diary. Follow instruction manual.
1% Density Deviation, 2% Moisture Deviation
Enter proctor value from materials
Enter applicable moisture correction – See pages 3-4 in Troxler Manual
Sign back in at end of day and clean equipment
TROUBLE SHOOTING
Do not charge batteries until “low battery” appears (2-3 hours remaining)
If the display reads “GM Tube A Error, Service Required”, remove and replace fuse; retry entry.
See 203.5 of the Engineering Policy Guide for information on testing with Nuclear Moisture-Density Gauges.
See http://scweb4/hq/co/radiation for routine maintenance issues.
Battery Voltage: 3.6, Normal
3.35-3.4, Battery low but serviceable
3.25-Below, No service