Home. Safe. Home. - HomeTeam Inspection Service

home inspection report
Home. Safe. Home.
Each office is independently owned and operated. | ©2013 The HomeTeam Inspection Service, Inc. All rights reserved.
What is a home inspection?
The purpose of a home inspection is to visually examine
the readily accessible systems and components of the home.
The inspectors are not required to move personal property,
materials or any other objects that may impede access or limit
visibility. Items that are unsafe or not functioning, in the opinion
of the inspector, will be described in accordance with the
standards of practice by which inspectors abide.
What does this report mean to you?
This inspection report is not intended as a guarantee, warranty
or an insurance policy. Because your home is one of the largest
investments you will ever make, use the information provided in
this report and discuss the findings with your real estate agent
and family to understand the current condition of the home.
Our inspections exceed the highest
industry standards.
FAST
Because we use a team of inspectors, each an expert in his or
her field, our inspections are performed with greater efficiency
and more expertise and therefore exceed the highest industry
standards. We are pleased to provide this detailed report as a
service to you, our client.
TRUSTED
We believe in your dream
of home ownership.
We want to help you get into your dream home. Therefore,
we take great pride in assisting you with this decision making
process. This is certainly a major achievement in your life. We are
happy to be part of this important occasion and we appreciate
the opportunity to help you realize your dream.
We exceed your expectations.
Buying your new home is a major decision. Much hinges on the
current condition of the home you have chosen. That is why we
have developed the HomeTeam Inspection Report. Backed by
HomeTeam’s experience with hundreds of thousands of home
inspections over the years, the report in your hand has been
uniquely designed to meet and exceed the expectations of
today’s homebuyers. We are proud to deliver this high-quality
document for your peace of mind. If you have any questions
while reviewing this report, please contact us immediately.
Thank you for allowing us the opportunity to serve you.
ACCURATE
FileNumber:SAMPLEREPORT
AddressofInspection:1234FifthStreet
PLEASEREADTHISENTIREREPORT,FROMBEGINNINGTOEND,BEFORETHEPROPERTYINSPECTION
CONTINGENCYPERIODINYOURCONTRACTWITHTHEPROPERTYOWNEREXPIRES.ONCETHEPROPERTY
INSPECTIONCONTINGENCYPERIODEXPIRES,YOUMAYNOTBEABLETOCANCELYOURPURCHASE
CONTRACTBASEDUPONTHERESULTSOFTHISORANYOTHERINSPECTION.
DONOTRELYUPONTHISSUMMARYOFTHEINSPECTIONREPORT.THESUMMARYISNOTINTENDEDTOBE
COMPREHENSIVE.
YOUMUSTREADTHEENTIREINSPECTIONREPORTWHICHCONTAINSMOREDETAILEDDESCRIPTIONSOF
THESUMMARYNOTESANDTHEPROPERTYANDITSSYSTEMSANDCOMPONENTS.SECTIONHEADINGSIN
THEREPORTAREFORREFERENCEPURPOSESONLYANDDONOTAFFECTTHEMEANINGOR
INTERPRETATIONOFTHEREPORT.THEORDERINWHICHTHESYSTEMSANDCOMPONENTSOFTHE
PROPERTYAREPRESENTEDISNOTINTENDEDTOREFLECTTHERELATIVEIMPORTANCEOFANYSYSTEM
ORCOMPONENTOFTHEPROPERTY.YOUMUSTDETERMINETHEIMPORTANCEOFEACHSYSTEMAND
COMPONENTOFTHEPROPERTYFORYOURSELF.
MinorDefects
Somecrackingoftheasphaltdrivewaymaterialwasobserved.Werecommendsealingthisdrivewaywiththe
appropriatematerialaspartofacontinuousmaintenanceprogram.
Somecrackingandheavingofthegaragefloorwasobserved.Werecommendthatallcracksbesealedand
monitoredforfuturemovementandtopreventfurtherdeterioration.
NOTE:Waterstainingonthewoodenroofstructureatthechimneyswasobservedintheattic.These
stainswerenotdamptothetouchatthetimeofinspection.Theyareanindicationofpastmoisture
intrusion.Withoutinspectingthisareaduringaprolongedperiodofrainwecannotdetermineifthe
leakingisstillactiveornot.Ifwealsonotedanyissuesattheexteriorre;caulking,roofshingles,
flashing,spalling,chimney,etcthenwerecommendthatyouseekfurtherevaluationbyaroofing
contractor.
Waterstainswereobservedatceilingsand/orwalls.Werecommendthatyouaskthesellerforinformationonage
andsourceofstain(s).
SafetyConcerns
OneGFCIreceptaclewasnotfullyfunctional.Typically,thismeansthateitherthe"test"and"re-set"buttonswere
notworkingORthattheoutletstillhadelectricalpowerevenafteritwastripped.Werecommendreplacement
withanewGFCIreceptacle.
Activeknob&tubewiringwasobserved.Manypropertiesbuiltpriorto1940stillhavesomeactiveknob&tube
wiring.Duetoitsadvancedage,furtherevaluationofitbyanelectricalcontractorisrecommended.
Recommendfurtherevaluation
Therewasmuchcrackingattheblockwall(s)ofthegarage.Werecommendfurtherevaluationbyamasonry
contractortodeterminewhattypeofrepair,ifany,isnecessarytoensurefuturestructuralintegrityofthewall(s).
Someasbestos-likematerialwasobservedonthesupplypipingoftheboilersystem.
Page2of21
FileNumber:SAMPLEREPORT
AddressofInspection:1234FifthStreet
GENERALDESCRIPTION
Throughoutthisreport,theterms"right"and"left"areusedtodescribethepropertyasviewedfromthestreet.
Thecosmeticconditionofthepaint,wallcovering,carpeting,windowcoverings,etc.,arenotaddressed.Allconditions
arereportedastheyexistedatthetimeoftheinspection.Routinemaintenanceandsafetyitemsarenotwithinthe
scopeofthisinspectionunlesstheyotherwiseconstitutematerialdefects.Althoughsomemaintenanceand/orsafety
itemsmaybedisclosed,thisreportdoesnotincludeallmaintenanceorsafetyitems,andshouldnotberelieduponfor
suchitems.
Theinspectedpropertyconsistedofatwostorystructurewithbricksidingthatwasoccupiedatthetimeofthe
inspection.Therewerenomaterialvisualdefectsonthevisibleportionsofthesiding.Theageoftheproperty,asreported
bythe ErieCountywebsitewassaidtobe 90-100yearsold.Theapproximatetemperatureatthestarttimeoftheinspection
was 70-80degreesFahrenheit,andtheweatherwas overcastwithsomerain.Theutilities wereonatthetimeofthe
inspection.The seller waspresentduringtheinspection.
Topography
Thepropertywassituatedonamostlylevellot.Thegeneralgradearoundthepropertyappearedtobeadequateto
directrainwaterawayfromthefoundationatnoneofthesides.
Walkway(s)
Therewasanasphaltwalkwayleadingtoastonestoopatthefrontoftheproperty.Triphazardswerenotvisibly
presentatthewalkway(s).
NOTE:Iftriphazardswerepresent,werecommendrepairtopreventpossiblefutureinjury.Therewerenomaterial
defectsobservedinthewalkwayorthestoop.
Driveway
Therewasanasphaltdrivewayatthefrontofthepropertywhichledtothedetachedgarage.Thedrivewaydidnot
visiblyslopetowardthepropertyand/orgarage(ifpresent).Therewerenomaterialdefectsobservedinthedriveway.
Werecommendthatyoukeepanyexistingcrackssealedtopreventdeteriorationand/orsettlingofthedrivewayinthe
future.
NOTE:Ifthedrivewaydoesvisiblyslopetowardthepropertyorgarage,werecommendthatyoumonitorforwater
intrusionintothepropertyorgarageduringheavyrainandaddexteriordrainageifneeded.
Page3of21
FileNumber:SAMPLEREPORT
AddressofInspection:1234FifthStreet
NOTE:Somecrackingoftheasphaltdrivewaymaterialwasobserved.Thisisnotuncommonwitholder
asphalt.Thedrivewaywasserviceableatthistime.Werecommendsealingthisdrivewaywiththeappropriate
materialaspartofacontinuousmaintenanceprogram.
NOTE:Adrainwaspresentatthedriveway,butappearedtobeclogged.Werecommendremovalofdebrisso
thedraincanfunction.
Patio
Therewasapatioofcementpaverslocatedattheproperty.Therewerenomaterialdefectsobservedatthepatio.We
recommendthatyoukeepanyexistingcrackssealedtopreventdeterioration.
GasService
Thepublicgasmeterwas/werelocatedinthebasement.Gaslineswhenpresentatapropertyarenottestedforleaks
orelectricalbonding.Suchtestingisbeyondthevisualscopeofinspection.Alicensedplumbingcontractorcould
performtheseinspectionsforyou.
NOTE:A11/2"metalpipe,usedforheatingoil,wascappedoffandvisibleatthefrontexteriorgroundlevel.
Page4of21
FileNumber:SAMPLEREPORT
AddressofInspection:1234FifthStreet
NOTE:Twofueloiltankswerepresentinthebasement.Thefueloiltankswerenotconnectedtothecurrent
heatingsystemfortheproperty.Evidenceofsignificantcorrosion/rustingonthetankwasnotvisible.
Evidenceofpastoractiveleakingfromthetankwasnotvisible.Theamountofheatingoilinthetankis
unknown.IfthisfueloiltankisNOTinusethenyoushouldexploreoptionsforremovalofit.
ElectricService
Theundergroundelectricservicewireenteredthepropertyattheexteriorsiding.Theelectricmeter(s)was/were
locatedontheexteriorwall.Theelectricmeter(s)wassecurelyattachedtotheproperty.
NOTE:Activeknob&tubewiringwasobservedattheattic,basementandcrawlspace.Duetoitsadvanced
age,wearandtear-alterations-mechanicaldamage-damagedinsulation,etcetcarelikely.Forthese
reasonsitisconsideredapotentialsafetyissue.Itisrecommendedtohaveanyactiveknob&tubewiring
furtherevaluatedbyanelectricalcontractor.Knob-and-tubewiringwascommoninwiringsystemsinstalled
before1940.Theinsulationisoftendryandbrittle,andchipseasily.Exposedareasshouldbe
insulated/repairedbyalicensedelectrician,andanymodificationstothewiringmustbemadebyalicensed
electrician.Knob&tubewiringwasdesignedasan"open-air"system,nottobecoveredwithattic
insulation.Inaddition,theoutletreceptaclesofaknob-and-tube-wiredsystemarenotgrounded.
Page5of21
FileNumber:SAMPLEREPORT
AddressofInspection:1234FifthStreet
Garage
Thedetachedgaragewasdesignedforonecarwithaccessprovidedbyoneelectricoverheaddoor.Theconcrete
garagefloorwasinaconditiontypicalfortheageofthisproperty.Therewerenomaterialdefectsobservedatthe
garage.
Page6of21
FileNumber:SAMPLEREPORT
AddressofInspection:1234FifthStreet
NOTE:Thepresenceofmanystoreditemsand/oraclutteredconditioninthegarageatticareaandparking
areablockedmuchofthevisualinspection,mostlyatfloorandalongthewalls.
NOTE:Someminorcrackinggaragefloorwasobserved.Thisisnotuncommonwitholderconcrete.The
garagefloorwasserviceableatthistime.
NOTE:Thereweresomemissingblocksattherightsideblockwall(s)ofthegarage.Moistureintrusionwas
presentatthegaragefloorbythisarea.Werecommendfurtherevaluationbyamasonrycontractorto
Page7of21
FileNumber:SAMPLEREPORT
AddressofInspection:1234FifthStreet
determinewhattypeofrepair,ifany,isnecessarytoensurefuturestructuralintegrityofthewall(s).
GarageOpener(s)
TheCraftsmanbrandelectricgaragedooropenersweretestedandfoundtobefunctional.Theautomaticsafety
reverseonthegaragedoor(s)wastestedandfoundtobefunctional.
DetachedGarageRoof
Theroofofthedetachedgaragewasagabledesigncoveredwithslateshingles.Observationoftheroofsurfacesand
flashingwasperformedfromaladder.Theageoftheroofcoveringwassameastheroofofthehomeyears.There
appearedtobeonelayerontheroofatthetimeoftheinspection.Therewerenomaterialdefectsobservedonthe
exteriorofthedetachedgarageroof.
Roof
Theroofofthepropertywasahipanddormerdesigncoveredwithslateshingles.Observationoftheroofsurfaces,
flashingandpenetrationsthroughtheroofwasperformedwithbinoculars.Theageoftheroofcoveringwas90-100
years.Thereappearedtobeonelayerofroofcoveringontheroofatthetimeoftheinspection.Thisvisualroof
inspectionisnotintendedasawarrantyoranestimateontheremaininglifeoftheroof.Thelifeexpectancyofaroofis
greatlyaffectedbyweatherconditions,ventilationandmaintenance.Anyroofmetal,especiallytheflashingand
valleys,mustbekeptwellpaintedwithapaintspeciallyformulatedfortheuse.Therewerenomaterialdefects
observedontheexterioroftheroof.
NOTE:Theabsenceofvisibleofvisualindicationsofwaterpenetrationinanattic,roof,orbasementatthetimeof
inspectionisNOTconclusiveevidencethattheattic,roof,andotherareasofthepropertyarefreefromleaksorother
waterpenetration.Oftenaninspectorcanobserveleaksonlyiftheinspectionisconductedduringaprolongedperiod
ofheavyrainfall.Theoccurrenceofoccasionalorintermittentleaksorseepageduringextremeweatherconditions
(ex;highwinds)iscommon.
NOTE:Sometimesouropinionofaroofmaydifferfromthatoftheinsuranceprovider/adjuster.Someinsurance
providers/adjustersaremoreparticularthanothers.Wearetheretostatetheoverallconditionoftheroofandtheroof
isnotconsideredtobedefectiveunlesstherearevisibleleaksand/ormajordamageorwearthatindicatesfailureis
imminent.Ifwenoteanymoderatetoseriouscurling,serioussurfacewear,orliftingedgesthenwe
recommendthatyougetapprovalfromyourinsuranceproviderregardingtheroof(s).
Page8of21
FileNumber:SAMPLEREPORT
AddressofInspection:1234FifthStreet
RoofDrainage
Theroofdrainagesystemconsistedprimarilyofcopperguttersanddownspoutswhichappearedtobefunctionalat
thetimeoftheinspection.Guttersanddownspoutsshouldreceiveroutinemaintenancetopreventprematurefailure.
Roofgutterswithpoorslopeorsaggingwerenotobservedattheproperty.Thedownspoutswentintostand-pipesat
theground.Therewerenomaterialdefectsobservedonthevisibleportionsoftheguttersordownspouts.
NOTE:Ifthedownspoutsterminateintostandpipesatgroundlevel,itisbeyondthescopeofthisvisualinspectionto
determinetheconditionofanyundergroundpiping.Onlyiftheinspectiontakesplaceduringaprolongedrainisit
possibletodetermineifanycloggingmaybepresentattheseundergroundpipes.
Chimney(s)
Thereweretwomasonrychimney(s)usedtoventtheboiler,waterheaterandfireplaces.Observationofthe
chimney(s)exteriorwasmadewithbinoculars.
NOTE:Masonrychimneys(especiallythose36"widthormore)belowtheroofridgeandwithoutsaddleflashingare
morepronetomoistureintrusion.Therewerenomaterialdefectsobservedonthechimney(s)exterior.Aswithall
elementsofthepropertyinspection,thefireplaceinspectionisnottechnicallyexhaustive.Theinspectionprovidesa
generalconditionreportonly.Theinspectiondoesnotincludetheinterioroffluesorchimneys,draftcharacteristics,
chimneyorfireboxintegrityortheadequacyofdraft,airflowormakeupair.Consultwithaqualified,reputablechimney
andfireplaceprofessionalforacompleteevaluationofanyfireplaceandchimney.
Attic/Crawl/RoofStructure
Theunfinishedatticspacewasaccessedthroughaceilingscuttleinthe2ndfloor.Theatticspacefloorwasinsulated
withcelluloseloose-fillinsulation,approximately6-inchesindepth.Theamountofinsulationpresentwasnotcloseto
oruptotoday'sstandards.Ifitwasnot,see"NOTE"atendofthissection.
Ventilationthroughouttheatticwasprovidedbyacombinationofvariousvents.Theunfinishedatticspace(s)did
appeartobeadequatelyvented.Thevisibleroofstructureconsistedoftwo-inchbysix-inchraftersspaced16inches
oncenterandwoodplankssheathing.Itwaspossibletoinspectallareasoftheunfinishedattic.Therewasno
moisturevisibleintheatticspace.Waterstainingwasvisibleontheroofstructureatattic(Theabsenceofvisible
indicationsofmoistureisnotnecessarilyconclusiveevidencethattheroofisfreefromleaks).Therewerenomaterial
defectsobservedintheatticorroofstructure.Mold/mildew-likesubstanceswerenotobservedintheattic.If
mold/mildew-likesubstanceswereobserved,buyersandsellersarerecommendedtoobtainfurtherinformationfrom
thefollowingsources:www.epa.gov/iaqwww.epa.gov/mold/index.htmlwww.iaqa.com
NOTE:Aswithallaspectsofthepropertyinspection,atticandroofinspectionsarelimitedinscopetothevisibleand
readilyaccessibleareas.Manyareasoftheroofarenotvisiblefromtheatticespeciallynearthebase,wherethe
largestvolumeofwaterdrains.Thepresenceoforactivestatusofroofleakscannotbedeterminedunlessthe
conditionswhichallowleakstooccurarepresentatthetimeoftheinspection.Pleasebeawarethatrainaloneisnot
alwaysaconditionthatcausesaleaktorevealitself.Theconditionsthatcauseleakstooccurcanofteninvolvewind
direction,thelengthoftimeitrains,etc.Theinspectiondoesnotofferorimplyanopinionorwarrantyastothepast,
presentorfuturepossibilityofroof,skylight,flashingorventleaks.
NOTE:Energydeficienciesarebeyondthescopeofthisinspection.Althoughtheamountofinsulationpresentmay
havebeenuptostandardswhenthehousewasbuilt,itisnotuptotoday'sstandardsandaddinginsulationcouldbe
beneficial.Werecommendthatyouconsultqualifiedcontractorsspecializinginenergyefficiencytofindoutif
additionalinsulationwouldbeawiseinvestment.
NOTE:Aproperlyventedatticwillprolongthelifeoftheroof,reduceleakagecausedbyicedamming,reduceenergy
bills,andreducemoisturebuild-upintheattic.
Page9of21
FileNumber:SAMPLEREPORT
AddressofInspection:1234FifthStreet
NOTE:Oneormorebathroomexhaustfansemptytheairintotheattic/crawlspace.Thisiscommonlyfound
inhomes,especiallyolderones,andwasastandardbuildingpracticeinthepast.Newerhomesventtheair
totheoutside.Therewerenovisibleissuespresentasaresultofthiscondition.
NOTE:Waterstainingonthewoodenroofstructureatthechimneyswasobservedintheattic.Thesestains
werenotdamptothetouchatthetimeofinspection.Theyareanindicationofpastmoistureintrusion.
Withoutinspectingthisareaduringaprolongedperiodofrainwecannotdetermineiftheleakingisstill
activeornot.Ifwealsonotedanyissuesattheexteriorre;caulking,roofshingles,flashing,spalling,
chimney,etcthenwerecommendthatyouseekfurtherevaluationbyaroofingcontractor.
WindowsandDoors
Arepresentativenumberofaccessiblewindowsanddoorswereoperated.Forwindowstobefunctional,theymust
open,stayintheopenposition,close,andlockproperly.Forexteriordoorstobefunctional,theymustopen,close,
andlockproperly.Possibleproblemareasmaynotbeidentifiedifthewindowsordoorshavebeenrecentlypainted.
Theprimarywindowswereconstructedofsteel,casementstyle,withsinglepaneandstormwindowglass.Allexterior
doorswereoperatedandfoundtobefunctional.Theexteriordoorlocksshouldbechangedorre-keyedupon
occupancy.Therewerenomaterialdefectsobservedinthewindowsordoors.
NOTE:Periodiccaulkmaintenanceisrecommendedaroundtheexteriorwindowanddoorframestopreventwater
intrusion.
Page10of21
FileNumber:SAMPLEREPORT
AddressofInspection:1234FifthStreet
Interior
Theinteriorwallandceilingsurfaceswereprimarilyfinishedwithlathandplaster.Possibleproblemareasmaynotbe
identifiediftheinteriorwallandceilingsurfaceshavebeenrecentlypainted.Signsofpreviousmoistureonwallsor
ceilingswereslightlyvisible.Therewerenomaterialdefectsobservedintheinteriorwallsorceilings.
NOTE:Thermaleffects,moistureandloadarefactorsthatcommonlyleadtosignsofminordistress,suchaslight
cracking,atinteriorwalls.Thestructuralwoodmembersinsidethewallsmayexpand&contractatvarioustimesofthe
year.
NOTE:Somepropertiesbuiltorremoldedfrom2001toPresentmayhavethetypeofdrywallthatcontainshighlevels
ofhydrogensulphideandammonia(sometimesreferredtoasChinesedrywallbecauseitwasfirstthoughttooriginate
mostlyfromChina).Thisproducthasbeenreportedtocausehealthissuesandcorrosivedamagetoanymetalinthe
propertysuchaselectricalwiring,plumbing,andHVACunits.Todate,thepresenceofthistypeofdrywallhasmostly
beeninthesouthernU.S.TheinspectionforandidentificationofthistypeofmaterialisNOTapartoftheproperty
inspection.Formoreinformation,pleasesee;http://www.doh.state.fl.us/Environment/community/indoorair/drywall.htmlandhttp://www.cpsc.gov/info/drywall/.
NOTE:Waterstainswereobservedatthe2ndfloorclosetceiling(s).Thesestainswerenotdamptothetouch
atthetimeofinspection.Stainsdoindicatepastmoistureintrusion.Itisunknownastowhetherthe
moistureintrusionisstillactiveornot.Werecommendthatyouaskthesellerforinformationonageand
sourceofstain(s).Ifthestainisonaceilingbelowabathroom,werecommendthatyouseekfurther
evaluationbyaplumbingcontractor.
Page11of21
FileNumber:SAMPLEREPORT
AddressofInspection:1234FifthStreet
2ndLevel
Thesecondlevelconsistedofsomebedroomsandbathrooms.Therewerenomaterialdefectsobserved.
NOTE:Thefollowingstandardsandinformationwasobtainedon-lineatthewebsitewww.stairways.org.Youmaycall
TheStairwayManufacturer'sAssociationformoreinformationtollfree:877-500-5759.Keepinmindthatmany
propertieswillnotconformtothesestandardsduetofactorsincluding;whenthepropertywasbuilt,localcodes,etc.
Porches,balconies,rampsorraisedsurfaceslocatedmorethan30-inchesabovethefloororgradebelowrequire
guardsandrailingstobeaminimumof36-inchesinheightinaprivatehomeand42-inchesinheightforamulti-unit.
Opensidesofstairswithatotalriseofmorethan30-inchesabovethefloororgradebelowshallhaveguardsnotless
than34-inchesinheightmeasuredverticallyfromthenosingofthetreads.Balusterorguardopeninglimitationsmust
notallowpassageofasphere4-inchesormoreindiameter.
1stLevel
Thefirstlivinglevelconsistedofthekitchen,livingroom,diningroom,bathroom,familyroom.Therewerenomaterial
defectsobservedonthefirstlevel.HomeTeaminspectsforevidenceofstructuralfailureandsafetyconcernsonly.
Thecosmeticconditionofthepaint,wallcovering,carpeting,windowcoverings,etc.,arenotaddressed.Theinterior
stairways(ifpresent)wereinspectedandtherewerenomaterialdefectsorvisualsafetyconcernsobservedwiththe
steps,stairwaysorhandrails.
NOTE:Thefollowingstandardsandinformationwasobtainedon-lineatthewebsitewww.stairways.org.Youmaycall
TheStairwayManufacturer'sAssociationformoreinformationtollfree:877-500-5759.Keepinmindthatmany
propertieswillnotconformtothesestandardsduetofactorsincluding;whenthepropertywasbuilt,localcodes,etc.
Porches,balconies,rampsorraisedsurfaceslocatedmorethan30-inchesabovethefloororgradebelowrequire
guardsandrailingstobeaminimumof36-inchesinheightinaprivatehomeand42-inchesinheightforamulti-unit.
Opensidesofstairswithatotalriseofmorethan30-inchesabovethefloororgradebelowshallhaveguardsnotless
than34-inchesinheightmeasuredverticallyfromthenosingofthetreads.Balusterorguardopeninglimitationsmust
notallowpassageofasphere4-inchesormoreindiameter.
ElectricSwitchesandReceptacles
Arepresentativenumberofinstalledlightingfixtures,switches,andreceptacleslocatedthroughoutthepropertywere
inspectedandwerefoundtobefunctional.Onlyafewoftheelectricalreceptacles(outlets)weregrounded.The
groundingandpolarityofreceptacleswithinsixfeetofplumbingfixtures,andthoseattachedtogroundfaultcircuit
interrupters(GFCI),ifpresent,werealsotested.Therewerenon-grounded(open-ground)receptacleswithinsixfeetof
plumbingfixturesatthe2ndfloorbathroom(seephoto)thatwerewithoutGFCIprotection.Forsafety,we
recommendtheadditionofaGFCIreceptacleorgroundingthereceptaclewhereverthisconditionmayexist.There
wereGFCIprotectedcircuit(s)locatedatthekitchen,bath(s)andexterior.AllGFCIreceptaclesandGFCIcircuit
breakersshouldbetestedmonthly.
NOTE:Mostpropertiesbuiltsincethemid1960'shave3prongoutletswithgroundedwiring.3prongoutletsprovide
anelectricalgroundforyourprotectionandtheprotectionofyourequipment,appliances,etc.Propertiesbuiltpriorto
the1960'softendonothave3prongoutletsorgroundedwiringunlesselectricalupdatinghastakenplace.
NOTE:Eachelectricaloutletisdesignedtohavethewiringconnectedinaspecificmanner.Improperconnections(ex:
reversedpolarity)cancreateanunsafecondition.Wetestasmanyoutletsaspossible,butsomemaynotbeavailable
fortestingduetoobstructionbyfurniture,bookcases,shelving,appliances,etc.
Page12of21
FileNumber:SAMPLEREPORT
AddressofInspection:1234FifthStreet
NOTE:Twoprongreceptacleswerepresentthroughouttheproperty.Atthetimethispropertywas
constructed,two-prongreceptacleswerethestandardconstruction.However,thetwo-prongedreceptacles
arenotgrounded(alsocalled"open-ground"),andarenotconsideredtomeetthesafetystandardsof
modernwiring.Theyaremorelikelytobeashockhazard.TheinstallationofGFCIreceptaclesinkitchens,
baths,garages,basements,outdoorreceptacles,andanyotherhigh-riskareas,willincreasetheoverall
safetyoftheelectricalsystem.2prongoutletswerepresentnearwateratthe2ndfloorbathroom.Ifso,we
recommendtheinstallationofGFCIoutletswherepresent.Wealsorecommendupgradingtogrounded
circuitsforanyappliancethatrequirespropergrounding,suchas:refrigerators,ranges,airconditioning
units.
NOTE:TheGFCIreceptacleatthedetachedgaragewasnotfullyfunctional.Thisisasafetyconcern.
Typically,thismeansthateitherthe"test"and"re-set"buttonswerenotworkingORthattheoutletstillhad
electricalpowerevenafteritwastripped.InsomecasesaGFCIreceptaclecanbetripped,butcannotbereset.AllofthesearecommonproblemswitholderGFCIreceptacles.Werecommendreplacementwithanew
onebyanelectricalcontractor.
NOTE:Accesstomanyoftheelectricaloutletswasnotpossibleduetoobstructionbyfurnishingsand/or
manystoreditems.
Page13of21
FileNumber:SAMPLEREPORT
AddressofInspection:1234FifthStreet
Fireplace
Agasfireplacewithchimneywaslocatedinthelivingroom.Thedamperdidappeartobefullyfunctional.Agaspilot
wasnotpresent.Thefireplaceburnerwaslitandworkingduringtheinspection.Aswithallelementsoftheproperty
inspection,thefireplaceinspectionisnottechnicallyexhaustive.Therewerenomaterialdefectsinthevisibleportions
ofthefireplaceduringourinspection.
Theinspectionprovidesageneralconditionreportonly.Ourinspectionofthefireplaceandchimneyis
limitedtothereadilyvisibleportionsonly.Thefireplaceinspectiondoesnotincludetheinterioroffluesor
chimneys,draftcharacteristics,chimneyorfireboxintegrityortheadequacyofdraft,airflowormakeupair.
Theinnerreachesofaflueareinaccessiblewithoutspecialtools.Ourdistantviewfromthetoporbottomisnot
adequatetodiscoverpossibledeficienciesordamage,evenwithastronglight.Therefore,becauseourinspectionof
chimneysislimitedtothoseareasthatcanbeviewedwithoutdismantlinganyportionofthem,anddoesnotinclude
theuseofspecializedequipment,wewillnotguaranteetheirintegrity.
NOTE:TheNFPA(NationalFireProtectionAssociation)recommendsthatalevelIIinspectionofthefireplacebe
performedbyachimneyspecialistateverytransferofresidentialproperty.Thiswilladdtoyourinspectioncosts,
however,itistheonlywaytobesurethatthefireplaceisinsafeworkingorder.Forsafeandefficientoperationwe
recommendannualinspectionsbyaqualifiedfireplaceprofessional.Aqualifiedfireplaceprofessionalwillcleanthe
interiorifnecessary,usespecializedtools,testingprocedures,mirrorsandvideocamerasasneededtoevaluatethe
fireplacesystem.
Page14of21
FileNumber:SAMPLEREPORT
AddressofInspection:1234FifthStreet
Fireplace
Awoodburningfireplacewithchimneywaslocatedinthebasement.Thedamperdidappeartobefullyfunctional.
Therewasnovisualevidenceofcreosotebuildupinthefirebox.Therewerenotanycracksand/ormissingmortar
observedinthefirebox.Thisfireplacewasnotlitandworkingduringtheinspection.Therewerenomaterialdefectsin
thevisibleportionsofthefireplaceduringourinspection.
Aswithallelementsofthepropertyinspection,thefireplaceinspectionisnottechnicallyexhaustive.The
inspectionprovidesageneralconditionreportonly.Ourinspectionofthefireplaceandchimneyislimitedto
thereadilyvisibleportionsonly.Thefireplaceinspectiondoesnotincludetheinterioroffluesorchimneys,
draftcharacteristics,chimneyorfireboxintegrityortheadequacyofdraft,airflowormakeupair.Theinner
reachesofaflueareinaccessiblewithoutspecialtools.Ourdistantviewfromthetoporbottomisnotadequateto
discoverpossibledeficienciesordamage,evenwithastronglight.Therefore,becauseourinspectionofchimneysis
limitedtothoseareasthatcanbeviewedwithoutdismantlinganyportionofthem,anddoesnotincludetheuseof
specializedequipment,wewillnotguaranteetheirintegrity.
NOTE:TheNFPA(NationalFireProtectionAssociation)recommendsthatalevelIIinspectionofthefireplacebe
performedbyachimneyspecialistateverytransferofresidentialproperty.Thiswilladdtoyourinspectioncosts,
however,itistheonlywaytobesurethatthefireplaceisinsafeworkingorder.Forsafeandefficientoperationwe
recommendannualinspectionsbyaqualifiedfireplaceprofessional.Aqualifiedfireplaceprofessionalwillcleanthe
interiorifnecessary,usespecializedtools,testingprocedures,mirrorsandvideocamerasasneededtoevaluatethe
fireplacesystem.NOTE:TheU.S.ConsumerProductSafetyCommission(CPSC)recommendsthateveryproperty
shouldhaveatleastonecarbonmonoxide(CO)alarm.COisanodorless,colorlessgasproducedbyburninganyfuel,
suchasgas,oil,wood,coal.
SmokeAlarms
Forsafetyreasons,thesmokealarmsshouldbeinstalledasneededand/ortesteduponoccupancy.Iftheproperty
weretobeconstructedtoday,standardswouldrequireinstallationofdetectorsineachsleepingroomandinthe
hallwayaccessingeachsleepingarea.Also,dwellingstypicallyrequireadetectoroneachlevelincludingthe
basement.Futureinstallationofadditionaldetectorsatanyunprotectedlocationissuggestedforincreasedfiresafety.
Thebuilt-intestbuttonwhenpresentonlyverifiesproperbatteryandhornfunction,butdoesnottestthesmoke
sensor.Wesuggestthattheunitsbetestedwithrealorsimulatedsmokeatmove-inandthatfreshbatteriesbe
installedasrequiredandtestedmonthlyasrecommendedbytheConsumerProductSafetyCommission.
Furthermore,ifanysmokedetectorismorethan10yearsold,werecommendreplacingitwithanewone.Asan
addedprotection,carbonmonoxidedetectorsshouldbepurchasedandinstalledaccordingtothemanufacturer's
recommendations.
Page15of21
FileNumber:SAMPLEREPORT
AddressofInspection:1234FifthStreet
Kitchen
Thevisibleportionsofthecabinetsandcountertopswereingoodcondition.Tobeingoodcondition,thecabinets
mustbeattachedtothewallorfloorandthecountertopsmustbesecurelyattachedtothecabinets.Built-in
appliancesthatarestayingwiththepropertywereturnedontocheckforbasicoperationalfunctiononly.No
temperaturecalibrationortestingforanextendedtimeisperformed.Nowarranty,expressorimplied,isgivenforthe
continuedoperationalintegrityoftheappliancesortheircomponents.Therewerenomajordefectsobservedatthe
kitchen.Thekitchencontainedthefollowingappliances:
Oven/Range/Cooktop
TheMagicChefandKitchenAidenaturalgasandelectricbuilt-inovenandcooktopwasinspectedanddidappearto
befunctional.Theaccuracyoftheclock,timersandsettingsonovensarenotwithinthescopeofthisinspection.
Refrigerator
TheAmanarefrigeratorwasinspectedanddidappeartobefunctional.Thetemperaturesettingandicemaker,if
present,arenotwithinthescopeoftheinspection.
TheGeneralElectricdishwasherwasobservedthroughacompletecycle(shortornormal)anddidappeartobefully
functional.
Disposal
TheKenmoredisposalwasinspectedanddidappeartobefullyfunctional.Theefficiencyratingisnotwithinthescope
oftheinspection.
Foundation
Thefoundationwasconstructedofterracottablockandbrick.Asingleinspectioncannotdeterminewhether
movementofafoundationhasceased.Whenthecrack(s)appeared,howlongittookforthecrack(s)todevelop,and
howthecrack(s)relatetoothersystemsofthepropertyarebeyondthescopeofthepropertyinspection.Anyexterior
orinteriorcracksshouldbesealed/patchedandmonitoredregularlyforanychanges.Ifchangesareobservedinthe
size,number,placement,oranyleakageisobserved,thenthecracksshouldbeexaminedbyamasonrycontractoror
structuralengineer.
NOTE:Itiscommonforbrick,concreteblock&pouredconcretewallstoshowsomecrackingduetoage,curing,initial
shrinkage,moistureshrinkage,normalthermalexpansionandcontractionofthesoil,foundationsettlement,orduring
back-filling.Thesearetypicallyonlysignsofdistress.Cracksnormallybecomeaconcernwhentheybegintoleak,
eithersideofthecrackmovesinrelationtotheotherside,orthewallitselforfloorbeginstotiltorbow.
Therewerenomaterialdefectsobservedonthevisibleportionsofthefoundation.
NOTE:Duetothepresenceoffinishedwalls,insulationpanels,manystoreditemsthefoundationwallsat
thebasementwereonlypartlyvisibleattheinteriorandthevisualinspectionwaslimited.
CrawlSpace
Thecrawlspaceunderthelivingroomwasaccessibleatthetimeoftheinspection,andwasdry.Itwaspossibleto
inspectallareasofthecrawlspace.Acrawlspaceshouldhaveavaporbarrier(polyvinylsheetingorconcrete)
coveringthesurfaceandshouldbeadequatelyventedatalltimes.Thecrawlspacedidnothaveavaporbarrier.The
crawlspacedidappeartohaveadequateventilation.Mold/mildew-likesubstanceswerenotobservedinthecrawl
space.Therewerenomaterialdefectsobservedinthevisibleportionofthecrawlspace.
Page16of21
FileNumber:SAMPLEREPORT
AddressofInspection:1234FifthStreet
Basement
Thepartialbasementwaspartiallyfinishedandcontainedthefollowingmechanicalsystems:theboilerandwater
heater.
BasementMoisture
Thebasementwasnotcompletelydryatthetimeoftheinspection.Somewaterstainswerevisibleonthewalls.
Indicationsofpresentmoisturewerevisibleonthefloorbytheoiltanks,thewaterheaterandwatermeter(see
photos).Somecrackingoftheconcretefloorwithwaterstainingatthecrackswasnotpresent.Amustyodorwas
present.Efflorescence(acrustywhite-ishresidueonmasonrywalls)wasnotvisibleonthewalls.Nosignsofpast
floodingwerevisibleontheflooratthistime.AninspectioncannotbeconclusiveonBasement/foundationwallsthat
haveinteriorfinishing(paint,sealant,paneling,drywall,etc).Awaterproofingpaintorsealantwasnotpresentonthe
foundationwalls.
Itisnotwithinthescopeofthisone-timepropertyinspectiontodetermineorpredicttheseverityor
frequencyofpastorfuturewaterintrusionintothebasement.Werecommendthatyouconsultwitha
companyspecializinginwaterproofingofbasementsifyourequireaguaranteeofa100percentdry
basement.
NOTE:Becausethebasementistypicallybelowgrade,thereexistsavulnerabilitytomoisturepenetrationafterheavy
rainsormeltingsnow.Basementleakageisoneofthemostcommonproblemsfoundinproperties.Mostofthewater
problemsinbasementsarearesultofgroundwaterinfiltrationduetoimpropergradingandneglectedguttersand
downspouts.Itisimportantthatallroofdrainageandsurfacewaterisdirectedawayfromthefoundation.
Masonry/concretefoundationmaterialsarenotwaterproof,unlesstreatedwithwaterproofmaterials.Interiorwall,
ceilingandfloorfinishingmayhideseriousleakageandmold.Dampnessonbasementwallsisnotalwaysasignof
waterintrusion.Thedampnesscanbetheresultofthecoolwallscomingintocontactwithwarmhumidair.Inmany
casesthehumidaircondensesonthewallandformsalayerof"sweat".Itisimportanttoassesswhethermoistureon
thebasementwallistheresultofwaterintrusionorcondensation.Condensationcanusuallybecontrolledbya
dehumidifier.Signsofcracksinexteriorpargingofthefoundationaregenerallysurfacecracksanddonotpenetrate
throughthefoundationwall.However,exteriorinspectionaloneisinconclusiveandtheinteriorfoundationwallsshould
bethoroughlyinspectedforcracksthatextendfromtheoutside.
Therewerenomaterialdefectsobservedinthebasement.Mold-likesubstanceswerenotobservedinthebasement.
Ifmold-likesubstanceswereobserved,buyersandsellersarerecommendedtoobtainfurtherinformationfromthe
followingsources:www.epa.gov/iaqwww.epa.gov/mold/index.htmlwww.iaqa.com
Page17of21
FileNumber:SAMPLEREPORT
AddressofInspection:1234FifthStreet
FloorStructure
Thevisiblefloorstructureconsistedofawoodplankingsubfloor,supportedbytwo-inchbyten-inchwoodjoists
spacedsixteeninchesoncenter.Therewasa5x10-inchsteelcenterbeam(s)andsteelpostsforloadbearing
support.
Mold/mildew-likesubstanceswerenotpresentonthevisiblefloorstructure.Rottedwoodwasnotpresentonthe
visiblefloorstructure.Waterstainingwasnotpresentonthevisiblefloorstructure.Therewerenomaterialdefects
observedatthevisibleportionsofthefloorstructure.
WaterService
Thewatermeterwaslocatedinthebasement.Themainwatershutoffvalveforthepropertywaslocatedadjacentto
thewaterserviceentrypointinthebasement.
FixturesandWaterPressure
Allaccessibleplumbingfixtureswereoperatedandinspectedforvisibleleaks.Supplyvalvessuchasthoseontoilet
supplyline,laundryroomhosebibs,faucetsupplylinesundersinks,dishwashersupplylines,andthemainwatershutoffareNOTtested.Thesevalveshavemostlikelynotbeenusedinsometimeandareverypronetoleakageifturned
offandon.
Waterflowthroughoutthepropertywasaverageforpublicwater.Waterpressurewasabletobetested.Ifso,itwas
foundtobe60-70poundspersquareinch.Therewerenomaterialdefectsobservedatthevisibleportionsofthe
plumbingfixtures.
NOTE:Wedonotoperate/checkexteriorbibsastheyarepronetoleaking,areinfrequentlyused,areoftenmissing
handlesandmaybeshut-offattheinterior.
SupplyLines
Thevisiblewatersupplylinesthroughoutthepropertywereprimarilycopperandgalvanizedsteelpipe.Thewaterwas
suppliedbyapublicwatersupply.Therewerenomaterialdefectsobservedatthevisibleportionsoftheplumbing
supplysystem.
NOTE:Anyoriginalgalvanizedsteelsupplypiping,ifpresent,issusceptibletofailure.Itisoftenasoldas
thepropertyitselfandthereforeatorneartheendofitsusefullife.
Page18of21
FileNumber:SAMPLEREPORT
AddressofInspection:1234FifthStreet
WasteLines
NOTE:Inmanyareasitisprohibitedtodischargesurfacewater,groundwater,stormwater,sumpwater,orroofwater
intothepublicsanitarysewersystem.Typically,onlywaterfrombathrooms,kitchen,laundry,andbasementfloor
drainsmayenterthepublicsanitarysewersystem.
NOTE:Theconditionofanypipingthatcouldnotbeobserved(undergroundservices,insideslabfoundation,behind
walls,behindinsulation,etc)isnotwithinthescopeofthepropertyinspection.
NOTE:Werecommendthatyouconsiderhavingthemainsewerline"scoped"(byaplumberorother
contractorspecializinginthistypeofservice)toensurethatthemainsewerline,frompropertytocity
connect,isfunctioningproperlyasitisunderground,notvisibleandisunabletobeviewedatthetimeof
inspection.Thisisparticularlyadvisableifthepropertyhashadahistoryofsewerbackupsorevidenceofbackups,if
thepropertyisolder,oriflargetreesarepresentonthelot.Toourknowledge,asof2012,Wesleyvilleistheonly
communityinErieCountythatcurrentlyrequires&conductstestingofthesewerlineswhenarealtytransaction
occurs.MillcreekTownshipSewer&WaterAuthorityisinthemidstofalongtermprogramofinspectingpropertiesfor
groundwaterinfiltrationintothesanitarysewersystem,buttheprogramisnotinvolveddirectlywithrealtytransactions.
MillcreekTownshipSewer&WaterAuthoritywillrequirethehomeownertomakenecessarycorrectionstotheir
propertyifgroundwaterinfiltrationisdetected.TheCityofEriedoesNOThaveacomparableprogramtoMillcreek
Townships.
Thevisiblewastelinesconsistedprimarilyofcastironandgalvanizedsteelpipe.Thefunctionaldrainageofthedrain
wastelineswasadequateatthetimeofinspection.Thepropertywasconnectedtoapublicsewersystemasreported
bytheMLSsheet.Thereweresomesignsofpreviousleakingand/oragerelatedcorrosiononsomeofthewastelines
throughouttheproperty.Therewerenomaterialdefectsobservedatthevisibleportionsoftheplumbingwaste
system.
WaterHeater
Therewasa50gal,naturalgaswaterheaterlocatedinthebasement.ThewaterheaterwasmanufacturedbyA.O.
Smith.Informationonthewaterheaterindicatedthatitwasmanufactured8-10yearsago.NOTE:Thoughsomeunits
maylastupwardsof20-30years,anywaterheaterolderthantenyearsshouldbeconsideredtobenearingtheend
ofitsnormallifeexpectancyandsubjecttofailureatanytime.
Atemperatureandpressurereliefvalve(T&P)waspresent.Becauseofthelimebuild-uptypicalofT&Pvalves,we
donottestthem.TheT&Pvalveshouldbetestedannuallybythehomeowner,andinspectedevery3yearsbya
plumbingcontractor.Anoverflowlegwaspresentonthewaterheater.Itdidterminateclosetothefloor.Yoursafety
dependsonthepresenceofaT&Pvalveandanoverflowlegterminatingclosetothefloor.
Therewasanadequateventingsystemfromthewaterheatertotheexterioroftheproperty.Thewaterheaterwas
functional.Therewerenomaterialdefectsobservedatthewaterheater.
ElectricPanel
TheserviceentrywireenteredaSquareDservicepanel,locatedonthebasementwallwitha200ampand120/240
voltratedcapacity.Thebranchcircuitswithinthepanelwerecopper.Thesebranchcircuitsandthecircuitbreakersto
whichtheywereattacheddidappeartobeappropriatelymatched.Therewasroominsidethepanelforanadditional
circuit(s)tobeaddedlater.Theservicepanelwasnotfull.Thevisiblewiringconsistedprimarilyoftheknobandtube
andromextypeandappearedtobeinfairtogoodcondition.
Page19of21
FileNumber:SAMPLEREPORT
AddressofInspection:1234FifthStreet
Theelectricalserviceappearedtobeinneedoffurtherevaluationbyanelectricalcontractorfortheknobandtube
wiring.Alarms,electronickeypads,remotecontroldevices,landscapelighting,telephoneandtelevision,andallelectric
companyequipmentwerebeyondthescopeofthisinspection.Therewerenomaterialdefectsobservedinthe
electricalsystem.Ifanysafetyissueswerepresent,werecommendthatyouseekfurtherevaluationand/orrepair
estimatesfromanelectricalcontractor.
HVACInspection
Theheatingsystemswereinspectedbythehomeinspector.Agasoroilfiredboilerisvisuallyinspectedandtestedfor
operationonly.Athoroughinspectionofagasoroilfiredboilerisnotpossiblewithoutremovingtheburnerstogain
completeaccesstotheheatexchanger.Inspectionofheatingandcoolingsystemsismechanicallylimitedsincethe
unitsarenotdismantledtoexamineinteriorcomponents.Annualmaintenanceoftheheatingequipment-cleaningthe
burners,servicingthecirculationpump,etcetc-isessentialforsafeandefficientperformance,whichwillmaximize
thesystem'susefullife.Beforecloseofescrow,recommendobtainingfromselleranydocumentsconcerningregular
maintenanceandserviceand/orasafetycheckbypublicutility,oracompletesystemevaluationbyaqualifiedheating
andcoolingspecialist,particularlyifheatingandcoolingcannotbeproventohavebeeninspectedwithinthepast
twelvemonths.Utilitycompanymayprovideafreesafetycheckofallgas-usingappliances.
Theresultsofourvisualandoperationalinspectionoftheheatingsystemaredescribedbelow.Thepropertywas
heatedbyaDunkirknaturalgassteamboilerwhichis15yearsold.Theunitwaslocatedatthebasementofthe
property.Ithasanapproximatenetheatingcapacityof225,000BTUH.Theheatingsystemwasfoundtobe
functional.TherewerenomaterialdefectsobservedattheHVACsystem.
NOTE:TheU.S.ConsumerProductSafetyCommission(CPSC)recommendsthateverypropertyshouldhaveatleast
onecarbonmonoxide(CO)alarm.COisanodorless,colorlessgasproducedbyburninganyfuel,suchasgas,oil,
wood,coal.
NOTE:Someasbestos-likematerialwasobservedontheboilerpipinginthecrawlspaceandbasement.The
positiveidentificationofthismaterialisbeyondthescopeofthehomeinspection.Ifyouareconcerned
aboutthepossibilityofhavingasbestostypematerialspresent,youcanhavethematerialsampledand
testedbyareputableenvironmentalcompany.ASBESTOSPIPE-Acommonmethodofinsulatingpipesin
manyhomesbuiltintheearlytwentiethcenturyinvolvedtheuseofasbestospipeinsulation.Asbestospipe
insulation,alsocalled"asbestospipewrap",isoneofthemorehazardoususesofasbestosbecauseitis
lessstablethanotherformsofasbestosmaterials.Generallyitissafetoassumethatinsulatedpipescontain
somesortofasbestospipeinsulationmaterial.Asbestospipeinsulationispronetodeteriorationandis
consideredafriableasbestosmaterial.Theparticlesreleasedwhenasbestospipeinsulationdeterioratesare
ahealthhazardandshouldnotbetakenlightly.
Page20of21
FileNumber:SAMPLEREPORT
AddressofInspection:1234FifthStreet
Radiators
Supplyradiatorsforthesteamorforcedhotwaterheatingsystemwerepresentatmostoftheroomsattheliving
levelsoftheproperty.Theywereoperationalatthetimeofinspection.Iftheywerenotalloperational,werecommend
contactinganHVACcontractor,specializinginhotwaterheating,forfurtherevaluation.Therewerenomaterial
defectsobservedattheheatingsystem.
Thermostat
Athermostatfortheheatingsystemwaspresentatthediningroomwalloftheproperty.Itwasmanufacturedby
Honeywellanddidappeartobefunctional.Therewillbenormaltemperaturevariationsfromroomtoroomandlevelto
level,mostnoticeablebetweenlevels.
WDI(pest)Inspection
Thewooddestroyinginsect(PEST)inspectionwasperformedbythehomeinspector(astatelicensedWDI
inspector).Acopyofthereportwillbegiventothebuyerandbuyer'sagentafterthetimeofinspection.Pleasereferto
thereportforpertinentinformation.Treatmentbyalicensedexterminatorwasnotrecommendedatthistime.
Page21of21