Fire Detection Systems - Amazon Simple Storage Service

Fire Detection Systems
Product Catalogue (Version 2014-03)
Product Sheet | Detecon
Version 2014-03
Product Catalogue
Fire Detection Systems
This product catalogue is intended for sales purposes only. For
planning, installation, commissioning and operation, please refer to the
corresponding operating instructions, which are enclosed with the products.
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Contents Page 1
Product Sheet | Detecon
Fire alarm and extinguishing control panels
FMZ 5000 base unit, FMZ 5000 mod S ................................1
FMZ 5000 modules/cards, FMZ 5000 mod S .......................1
FMZ 5000 complete BE .......................................................1
FMZ 5000 base unit .............................................................1
FMZ 5000 modules/cards .....................................................1
FMZ 5000 enclosure/front plates ..........................................1
FMZ 5000 power supply units ...............................................1
FMZ 5000 batteries ...............................................................1
FMZ 5000 fire alarm panel accessories ...............................1
FMZ 4100 cards ...................................................................1
-
2
4
8
9
19
45
48
51
53
56
-
1
2
4
-
2
7
15
18
21
28
32
34
36
37
-
2
3
4
5
6
10
11
12
13
14
15
16
18
Fire brigade and system accessories
Fire brigade control panels....................................................3
Fire brigade graphic annunciator ..........................................3
Graphic panel .......................................................................3
Manual call points
DMX indoor application, addressable ...................................4
DMX indoor application, conventional ...................................4
DMX indoor application, Ex ...................................................4
DMX indoor application, accessories ....................................4
DMX outdoor application, addressable ................................4
DMX outdoor application, conventional ................................4
DMX outdoor application, addressable, Ex ..........................4
DMX outdoor application, conventional, Ex .........................4
DMX outdoor application, accessories .................................4
DMX accessories, general ...................................................4
Standard - detectors
Optical smoke detectors, addressable ..................................5
Ionisation smoke detectors, addressable .............................5
Multisensor detectors, addressable ......................................5
Heat detectors, addressable ................................................5
Detector accessories, addressable .......................................5
Optical smoke detectors, addressable, Ex ...........................5
Ionisation smoke detectors, addressable, Ex .......................5
Heat detectors, addressable, Ex ..........................................5
Detector accessories, addressable, Ex ................................5
Optical smoke detector, conventional ..................................5
Ionisation smoke detectors, conventional ............................5
Heat detectors, conventional ................................................5
Detector accessories, conventional ......................................5
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Contents Page 2
Product Sheet | Detecon
Optical smoke detector, conventional ..................................5
Multisensor detectors, conventional .....................................5
Heat detector, conventional ..................................................5
Detector accessories, conventional ......................................5
Optical smoke detectors, conventional, Ex ...........................5
Ionisation smoke detectors, conventional, Ex .......................5
Heat detectors, conventional, Ex .........................................5
Detector accessories ............................................................5
Detector accessories, conventional, Ex ...............................5
Modules, addressable, DIN rail mounting ............................5
Modules, addressable, wall mounting ...................................5
Modules, addressable ...........................................................5
Modules, conventional .........................................................5
Test equipment .....................................................................5
Test equipment, accessories ................................................5
-
20
21
22
23
24
25
26
28
31
32
39
48
49
52
59
-
5
7
9
11
14
17
19
20
24
28
32
41
42
50
54
55
59
60
66
AMX 4004, basic devices .....................................................7
AMX4004, detector heads.....................................................7
HELIOS AMX5000, basic devices .........................................7
HELIOS AMX5000, detector heads ......................................7
Vesda Laser, basic devices ..................................................7
Sampling pipes......................................................................7
Aspirating pipes - connections/accessories .........................7
Aspirating tube system, mounting accessories ....................7
Fittings ..................................................................................7
-
1
3
4
6
8
11
13
15
16
OneU .....................................................................................7
-
22
Industrial detectors
UniVario IR flame detector ....................................................6
UniVario UV flame detector ..................................................6
UniVario Heat detector, standard .........................................6
UniVario High temperature heat detector FS .......................6
UniVario High temperature heat detector FS Flex ...............6
UniVario IR flame detector, Ex .............................................6
UniVario UV flame detector, Ex ............................................6
UniVario Heat detector, Ex standard .....................................6
UniVario High temperature heat detector FS, Ex ..................6
UniVario High temperature heat detector FS Flex, Ex ..........6
UniVario Detector accessories ..............................................6
UniVario Test equipment ......................................................6
IR flame detector ..................................................................6
IR flame detector, Ex ............................................................6
UV flame detector, Ex ...........................................................6
Detector accessories ............................................................6
Flame detector accessories .................................................6
Gas emisson detector ..........................................................6
Gas emission detector, Ex ...................................................6
Aspirating smoke detectors
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Contents Page 3
Product Sheet | Detecon
Special detectors
Linear smoke detectors .........................................................8
Linear smoke detectors, accessories ....................................8
Cyklone montoring ...............................................................8
Cyklone monitoring, Ex ........................................................8
-
1
2
5
6
-
1
10
14
20
39
43
48
61
66
73
-
1
-
1
-
1
Means of alarm
Audible ..................................................................................9
Audible, addressable ............................................................9
Audible, Ex ............................................................................9
Visual ...................................................................................9
Visual, addressable ..............................................................9
Visual, Ex .............................................................................9
Audible/visual .......................................................................9
Audible/visual, addressable .................................................9
Audible/visual, Lighted warning display ...............................9
Audible/visual, Ex .................................................................9
Gas detection
Gas detection .....................................................................10
Door hold-open technique
TSZ 5000 ...........................................................................11
Cable/installation material
Cable/installation material ...................................................12
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com | Contents Page 4
Product Sheet | Detecon
Fire alarm and extinguishing control panels
FMZ 5000 base unit
FMZ 5000 - A fire alarm panel range for all safety concepts
Each FMZ 5000 model is a highly modern unit combining
¿re alarm and extinguishing control in a fully modular design
with freely programmable controls to suit virtually any project
requirement.
Planning, operation and service made easy
The same hardware modules are used for both ¿re detection
systems and extinguishing systems, in three different base
unit layouts for wall-mounted installation or in 19" freestanding cabinets. The MxSysCon con¿guration program with
full graphical user interface is used to adapt those hardware
modules to the speci¿c project, in the of¿ce or on site any
time right up to the moment of startup.
Optimal value for money – you only buy what you
currently need
Changes in building use, in ¿re alarm controls or to your ¿re
protection system can be implemented easily in the FMZ
5000 by replacing / adding / removing plug-in modules and
adapting the con¿guration. Rewiring within the ¿re alarm
panel is not required.
State of the art technology
P31.301.410en / 02.13
- All modern functions of today's ¿re alarm and extinguishing control panels are combined in a single device:
•
Clear display of alarms and other signals and easy operation in every situation with the large graphical display screen and
user menu interface.
•
Loop technology for detection / control / monitoring with all modern features and any number of branches - including
explosion hazard areas.
•
Operation of detectors for rough industrial environments in a wide range of operating voltages for all ¿re characteristics
(such as heat - smoke - Àame - CO ¿re gas etc.), also directly connected without couplers on one Loop.
•
Up to 32 ¿re alarm and display/operating panels can be redundantly loop networked.
•
Communication with building management systems or other control stations via open interfaces or ¿eld bus protocols.
•
The freely programmable user interface meets all requirements for the display of messages and the controls to be executed
in any logical and time combination.
•
Redundant layout for ¿re detection and control of multi-zone extinguishing systems of any type.
•
Easy adaptation to changing conditions of use and tasks through plug-in modules and graphical con¿guration.
A ¿re alarm panel system for universal application, with two VdS device approvals
G204124 ¿re alarm panel in accordance with EN54-2 A1 : 2006, EN54-4 A2 : 2006; 0786-CPD-20843
G205019 Electrical control device for multi-zone gas extinguishing systems in accordance with EN12094-1 :2003; 0786 - CPD - 20222
•
International approvals like FM, CCC, RU for all main markets.
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 1 - 1
Product Sheet | Detecon
Fire alarm and extinguishing control panels
FMZ 5000 base unit
Order no.: 909222
Fire alarm panel FMZ 5000 mod S
Application
Use as ¿re detection and extinguishing control panel in
single-zone water or gas extinguishing systems, as spark
detection and spark extinguishing control panel as well as in
applications with groups ¿re detection, such as for the protection of machines or paint shops.
Product features
•
6 detector groups for any type of conventional detectors,
thereof 4 for instantaneous ¿re detection.
•
3 control groups.
•
8 open collector outputs for connecting relays.
50 Hz - 60 Hz
•
Collective and individual LED‘s, partly red/yellow.
Operating voltage
26.5 V DC
•
Power supply unit
26.5 V DC / 3 A
Quiescent current
250 mA
max. 26 Ah, 12 Ah battery in the
housing
26.5 V DC
Extendable by function modules
- Fire brigade periphery for connection of all kind of ¿re
brigade components
- Communication card for connection to external control
facilities and printers
- Spark test card for connection of spark test detectors
for testing spark detectors
•
Suitable for integration into a ring network with further
Minimax control panels.
30 W / 62.5 VA
•
Large fully graphic LC display with menu navigation.
-5 °C to +40 °C (+23 °F to +104 °F)
max. 95 %
no condensation
Sheet steel
•
Key switch as access to the direct operation of detector
and control groups.
Technical specifications
Mains voltage
115 V / 230 V AC -10% +15%
Mains frequency
Battery capacity, max.
External control voltage
Collective relays
Contact load
¿re / fault in each case
1 A / 30 V DC, 0.5 A / 125 V AC
Max. switching capacity
Ambient temperature
Relative humidity
(IEC721-3-3)
Enclosure
Dimensions ca.
body
body door
IP rating (EN60529)
Color
P31.301.410 - 1en / 01.14
Compact control panel of the FMZ 5000 control panel family
accommodated in a wall housing. The housing is also suitable for Àush-mounted installation in a wall or console. For operation of conventional detectors in standard design or suitable
for industrial applications and for the monitored triggering of
alarm devices, valves and release devices.
Optional modules allow for the additional connection and
operation of:
- Two transmission devices for ¿re and fault, one ¿re brigade
operating panel, ¿re brigade display panel and ¿re brigade
key deposit in each case
- Interfaces for the data transfer to management systems,
printer, control panel networks and remote diagnostics
- Test of installed spark detectors during operation
- Relay card RK8 or RK8TQ
440 x 500 x 116 mm (WxHxD)
17.3 x 19.7 x 4.6 inch (WxHxD)
464 x 515 x17 mm (WxHxD)
18.3 x 20.3 x 0.7 inch (WxHxD)
IP 42
RAL 7035
approx. 10.6 kg (23.4 lbs)
without batteries
Wall-mounted installation
Weight
Mounting
Approvals / marking
G 211052
G 211123
0786-CPD-21081
0786-CPD-21136
Included in delivery
Control panel with display and operating front panel, mainboard with power pack, conventional control groups and open
collector outputs, wired ready for operation.
Operating manual, log book, mounting material.
Key, switch
911745
Key, door
767588
Not included in delivery
Coprocessor FMZ 5000 mod S basic
advanced
premium
Relaycard RK8
RK8TQ
cable set FMZ 5000 mod S
Installation material, function modules, batteries.
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 1 - 2
909560
909571
909572
802587
800843
913673
Product Sheet | Detecon
Fire alarm and extinguishing control panels
FMZ 5000 base unit
Fire alarm panel FMZ 5000 mod S IP 54
Order no.: 911027
Application
Compact control panel of the FMZ 5000 ¿re detection control
panel family in a wall case with IP 54 rating according to
EN60529.
For use in environments exposed to heavy soiling or dust
incidence.
Owing to its IP 54 rating, the control panel is suitable without
any restriction for monitoring water extinguishing systems in
accordance with CEA 4001.
Technical specifications
Dimensions ca.
body
body door
IP rating (EN60529)
Supplementary ¿re panel
with 2 knurled screws for locking
approx. 11 kg (24.3 lbs) without
batteries
Otherwise like order no.: 909222
Approvals / marking
G 211052
G 211123
0786-CPD-21081
0786-CPD-21136
P31.301.410 - 1en / 01.14
Weight
440 x 500 x 116 mm (WxHxD)
17.3 x 19.7 x 4.6 inch (WxHxD)
464 x 515 x 34 mm (WxHxD)
18.3 x 20.3 x 1.4 inch (WxHxD)
IP 54
In order to seal the operating front panel, the case is equipped additionally with a supplementary ¿re panel with knurled
screws for locking.
Additional pre-cut openings for cables are located at the
bottom of the case.
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 1 - 3
Product Sheet | Detecon
Fire alarm and extinguishing control panels
FMZ 5000 modules/cards
FMZ 5000 mod S communication card
Order no.: 909367
Function module for installation into an FMZ 5000 mod S with
2 data interfaces for communication with other devices or
communication via the Internet
One interface corresponds to the RS232 standard with freely
con¿gurable interface parameters.
The other one is designed as Ethernet interface for remote diagnostics and remote control by means of the TCP/IP
protocol.
Application
Product features
•
RS232 interface with 9-pole Sub-D female connector.
•
The interface parameters are adjustable through
con¿guration.
•
•
•
•
Data transfer to PCs or control centers via Mx2 protocol.
Ethernet interface with RJ-45 female connector for data
communication through TCP/IP protocol.
•
For both interfaces, data transfer is also possible by
means of converters via ¿bre optic cables.
Connection of a MxNet module for integrating the
FMZ 5000 mod S in the path-redundant control panel
MxNet ring network.
•
Data access via Internet and Web browser for remote
diagnostics or remote control to reduce the expenditure
for service and maintenance work.
Technical specifications
Operating voltage
Quiescent current
Data interfaces
Ambient temperature
Relative humidity
(IEC721-3-3)
IP rating (EN60529)
Mounting
26.7 V DC
(Ethernet on) 10 mA DC
(Ethernet off) 30 mA DC
1 RS232
1 Ethernet
-5 °C to +40 °C (+23 °F to +104 °F)
max. 95 %
no condensation
IP 20
On the mainboard rear side
Weight
Dimensions
Approvals / marking
See panels
P31.301.421 - 1en / 02.13
Interface for data communication and message transmission.
46 g (0.1 lbs)
75 x 82 x 40 mm (WxLxD)
3 x 3.2 x 1.6 inch (WxLxD)
Connection of a printer for printout and logging
messages and statuses. Printer types selectable through
con¿guration.
Included in delivery
Module ready for installation including fastening material.
Not included in delivery
Coprocessor FMZ 5000 mod S advanced
909571
Cable connector and connecting cables for the data line
Note
Data cable for RS232 interface, max. length 10 m. Use
converters for longer cables.
Select the cable type according to the cable length and the
intended purpose.
Use CAT5 or CAT7 cables with RJ-45 connector for Ethernet.
For safety and availability reasons, do not use any Ethernet
cabling that is simultaneously used by other services for the
data transfer required by the construction law.
One communication module can be installed into each control panel.
The card can only be used with the Coprocessor FMZ 5000
mod S advanced or premium. The Coprocessor has to be
ordered separately.
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 1 - 4
Product Sheet | Detecon
Fire alarm and extinguishing control panels
FMZ 5000 modules/cards
FMZ 5000 mod S spark test card
Order no.: 909366
Function module for installation into an FMZ mod S for testing spark detectors.
Up to 4 spark detector groups can be tested by means of the
module and connected spark test actuators without interruption of the monitoring process.
Application
Product features
•
4 test outputs for connection of one test actuator each.
•
Function test of the spark detectors without interruption
of the monitoring process.
•
Test either manual or at con¿gured times with or without
release of the extinguishing.
•
Monitoring of the test actuators during the test.
•
Intensity of the test impulse adjustable in four steps.
Included in delivery
Module ready for installation including fastening material.
Not included in delivery
Technical specifications
Operating voltage
26.7 V DC
Quiescent current
(test outputs inactive) 10 mA DC
Test outputs
Max. test current
Ambient temperature
Relative humidity
(IEC721-3-3)
IP rating (EN60529)
4
1 A DC
-5 °C to +40 °C (+23 °F to +104 °F)
max. 95 %
no condensation
IP 20
Mounting
On the mainboard rear side
Weight
100 g (0.2 lbs)
76 x 147 x 40 mm (WxLxH)
3 x 5.8 x 1.6 inch (WxLxH)
Dimensions
For testing installed spark detectors by means of a short light
impulse which is emitted by a connected test actuator after
triggering. The intensity of the light impulse is adjustable.
Practice-oriented test because integrates in the material
Àow during operation. Any undetected light impulse will be
reported as a fault. The test can be started either manually or
at con¿gured daily times.
Coprocessor FMZ 5000 mod S premium
Test actuators and installation material
909572
Note
One module can be installed into each control panel.
The test function can only be used in connection with spark
extinguishing lines.
The card can only be used with the Coprocessor FMZ 5000
mod S premium. The Coprocessor has to be ordered separately.
Approvals / marking
P31.301.421 - 2en / 02.13
See panels
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 1 - 5
Product Sheet | Detecon
Fire alarm and extinguishing control panels
FMZ 5000 modules/cards
FMZ 5000 mod S card
fire brigade periphery
Order no.: 909365
Function module for installation into an FMZ 5000 mod S with
all interfaces for connecting components to call and inform
the ¿re brigade, for the control panel operation by the ¿re
brigade as well as for the non-violent access to the object via
the key deposit.
Functions and connections comply with DIN 14675, DIN
14661, DIN 14662, and VdS 2350.
Product features
Application
•
One RS422 interface for connecting a ¿re brigade
operating panel with serial data transfer.
For triggering and monitoring all ¿re brigade components,
such as:
•
One RS422 interface for connecting a ¿re brigade
display panel with serial data transfer.
•
Trigger interface for ¿re brigade key deposit adapter
(FSD) with triggering of the door opening as well as
monitoring of door contact and tamper-proof line.
•
Trigger interface for the transmission device ¿re.
•
Trigger interface for the transmission device control.
•
One transmission device each for ¿re and fault
messages.
•
Connection of one serial ¿re brigade operating panel
and display panel .
•
One adaptor for connecting a ¿re brigade key deposit.
Included in delivery
Module ready for installation including fastening material.
Not included in delivery
Coprocessor FMZ 5000 mod S basic
Connecting lines and data cable.
Technical specifications
Operating voltage
26.7 V DC
Quiescent current
30 mA DC
Data interfaces
Component interfases
Ambient temperature
Relative humidity
(IEC721-3-3)
IP rating (EN60529)
Mounting
2 RS422
Connection transmission device ¿re,
fault, FSD adapter
-5 °C to +40 °C (+23 °F to +104 °F)
max. 95 %
no condensation
IP 20
On the mainboard rear side
Weight
Dimensions
909560
Note
Data cable for RS422 interface, max. length 1000 m. Use
converters for longer cables.
Select the cable type according to the cable length and intended purpose.
One ¿re brigade interface module can be installed in each
control panel.
The card can be used with the Coprocessor FMZ 5000 mod
S basic, advanced or premium. The Coprocessor has to be
ordered separately.
139 g (0.3 lbs)
208 x 83 x 40 mm (WxLxH)
8.2 x 3.3 x 1.6 inch (WxLxH)
Approvals / marking
P31.301.421 - 3en / 02.13
See panels
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 1 - 6
Product Sheet | Detecon
Fire alarm and extinguishing control panels
FMZ 5000 modules/cards
FMZ 5000 mod S Basic coprocessor
Order no.: 909560
Functional characteristics are added to the ¿rmware of the
¿re alarms and FMZ 5000 extinguishing control unit via the
coprocessor and the processing of various complex applications thereby made possible.
Technical specifications
Weight
Dimensions
45 g (0.1 lbs)
31 x 26 x 7 mm (WxHxD)
1.2 x 1 x 0.3 inch (WxHxD)
The Basic coprocessor is required for the following applications:
• control and monitoring of electric alarms in sprinkler
systems and elimination of hydraulically operated
alarm bells
• protection of machine tools
Note
The coprocessor must be insert into the appropriate socket
on the mainboard of the control unit.
When changing the applications the coprocessor can be
exchanged for another type.
FMZ 5000 mod S Advanced coprocessor
Order no.: 909571
The Advanced coprocessor is required for the following
applications:
• Filling and drainage station, Hydrant
• Filling and drainage station maximat FuE1
• Filling and drainage station maximat FuE2
• Filling and drainage station maximat FSX LWT
otherwise as for Order no. 909560
FMZ 5000 mod S Premium coprocessor
Order no.: 909572
The Premium coprocessor is required for the following applications::
• control and monitoring of gas extinguishing systems with
Co2 or chemical gases
• protection of IT rooms
• control and monitoring of pilot-guided VMX dry pipe valve
stations
• control and monitoring of DiMX separator stations
P31.301.421 - 4en / 02.13
otherwise as for Order no. 909560
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 1 - 7
Product Sheet | Detecon
Fire alarm and extinguishing control panels
FMZ 5000 complete BE
Fire alarm panel FMZ 5000 mod 4 L GW
Order no.: 908593
Compact ¿re alarm panel of the ¿re alarm panel range
FMZ 5000.
Equipped and ready for ¿re detection in conventional line
technology for a maximum of 128 detectors, monitoring and
control of a single-zone extinguishing system.
Signal indication through large LC display and LEDs,
menu-guided operation using con¿gurable function keys.
Application
Product features
For use as ¿re alarm and extinguishing control panel in
single-zone extinguishing systems.
•
Expansion of the ¿re alarm panel is designed for
controlling a single-zone extinguishing system.
•
4 conventional detector lines, 4 control groups, 8 relays
with 1 potential-free changeover contact each.
•
The ¿re alarm is completely precon¿gured and ready for
operation.
•
Collective signal LED and individual LED pairs, red/
yellow, for status indications.
•
Large LC display, fully graphical with menu-driven
operation.
•
Emergency power batteries 12 Ah.
Technical specifications
Mains voltage
115 V / 230 V AC ±15%
Mains frequency
50 Hz - 60 Hz
Operating voltage
21 V - 29 V DC
Power supply unit
24 V DC / 3 A
Quiescent current
225 mA DC
Battery capacity, max
2 x 12 V / 12 Ah
External control voltage
Contact load
21 V - 27.2 V DC
1 A / 30 V DC, 0.5 A / 125 V AC
Max. switching capacity
Ambient temperature
Relative humidity
(IEC721-3-3)
30 W /62.5 VA
-5°C to + 40°C (+23 °F to +104 °F)
max. 95 %
no condensation
Enclosure
Sheet steel 4U
Dimensions
IP rating (EN60529)
Speci¿cation according to
Color
Weight
Mounting
475 x 340 x 200 mm (WxHxD)
18.7 x 13.4 x 7.9 inch (WxHxD)
IP 54
EN 54-2 A1: 2006
EN 54-4 A2: 2006
EN 12094-1: 2003
RAL 7035
approx. 20 kg (44.1 lbs)
incl. batteries
Wall-mounted installation
Included in delivery
Fire alarm panel with front display and operating plate,
central card and power supply unit, and one conventional
detector module, control group module and relay module
each as well as a zone operating panel card. 2 x 12 Ah
batteries.
Wired ready for operation and precon¿gured.
Operating instructions, terminal assignment, operator's log,
installation manual, Drilling template.
P31.301.640en / 02.13
Approvals / marking
G 204124
G 205019
0786-CPD-20843
0786-CPD-20222
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 1 - 8
Product Sheet | Detecon
Fire alarm and extinguishing control panels
FMZ 5000 base unit
Order no.: 908551
Fire alarm panel FMZ 5000 mod 4
NT5100 3A
Smallest base unit in the modular ¿re alarm panel range
FMZ 5000.
The wall enclosure is also suitable for Àush-mounted wall
installation or for desk mounting.
For connecting addressable detectors and conventional
detectors in standard or industrial design.
Activation of remote transmission units for ¿re and fault
signals, data communication data transfer to management
systems and control stations with open interfaces.
Signal indication through large LC display and LEDs,
menu-guided operation using con¿gurable function keys.
Application
For use for pure ¿re detection control or combined ¿re
detection and extinguishing control in small-scale projects.
Also for controlling multi-zone extinguishing systems through
redundant hardware.
Technical specifications
Mains voltage
•
Free selection of functional modules to be used for all
project tasks. Space for up to 8 modules available.
•
Can also be expanded for control of multi-zone
extinguishing systems with redundant hardware.
•
Up to 4 detector loops with 126 detectors each, 16
conventional detector lines for 32 detectors of any design
each.
115 V / 230 V AC ±15%
Mains frequency
50 Hz - 60 Hz
Operating voltage
21 V - 29 V DC
•
Up to 16 control groups and 32 relays.
Power supply unit
24 V DC / 3 A
•
Quiescent current
120 mA DC
14 collective signal LEDs, some in two colours, 16 LED
pairs, red/yellow, for individual signal indications.
•
Large LC display, fully graphical with menu-guided
operation.
•
Can be loop networked up to 32 units in total.
•
The enclosure has space for emergency power batteries
up to 12 Ah.
•
All settings are carried out via a fully graphical interface
on a PC with the MxSysCon con¿guration program.
Battery capacity, max
12 Ah internal
External control voltage
Ambient temperature
Relative humidity
(IEC721-3-3)
Enclosure
Dimensions
IP rating (EN60529)
Speci¿cation according to
Color
Weight
Mounting
21 V - 29 V DC
-5°C to +40°C (+23 °F to +104 °F)
max. 95 %
no condensation
Sheet steel 4U
475 x 340 x 200 mm (WxHxD)
18.7 x 13.4 x 7.9 inch (WxHxD)
IP 54
EN54-2 A1:2006
EN54-4 A2:2006
EN12094-1:2003
RAL 7035
approx. 15 kg (33.1 lbs)
without modules
Wall-mounted installation
Approvals / marking
P31.301.410 - 3en / 02.13
Product features
G 204124
G 205019
0786-CPD-20843
0786-CPD-20222
Included in delivery
Fire alarm panel with front display and operating plate,
central card and power supply unit.
Wired ready for the insertion of any modules.
No additional wiring in the ¿re alarm panel required.
Operating instructions, operator's log, installation manual,
drilling template.
Not included in delivery
Modules, zone operating panel cards, batteries, report
printer, installation material.
Note
Alternative power supply unit and batteries must be selected
according to the table at the end of the chapter.
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 1 - 9
Product Sheet | Detecon
Fire alarm and extinguishing control panels
FMZ 5000 base unit
Order no.: 905231
Fire alarm panel FMZ 5000 mod 4
Smallest base unit in the modular ¿re alarm panel range
FMZ 5000.
The wall enclosure is also suitable for Àush-mounted wall
installation or for desk mounting.
For connecting addressable detectors and conventional
detectors in standard or industrial design.
Activation of remote transmission units for ¿re and fault
signals, data transfer to management systems and control
stations with open interfaces.
Signal indication through large LC display and LEDs,
menu-guided operation using con¿gurable function keys.
Application
Product features
For use for pure ¿re detection control or combined ¿re
detection and extinguishing control in small-scale projects.
Also for controlling multi-zone extinguishing systems through
redundant hardware.
•
Free selection of functional modules to be used for all
project tasks. Space for up to 8 modules available.
•
Can also be expanded for controlling multi-zone
extinguishing systems with redundant modules
•
Up to 4 detector loops with 126 detectors each, 16
conventional detector lines for 32 detectors of any design
each.
Technical specifications
Mains voltage
Mains frequency
115 V / 230 V AC -15%, +10%
50 Hz - 60 Hz
Operating voltage
21 V - 29.6 V DC
•
Up to 16 control groups and 32 relays.
Power supply unit
24 V DC / 1.5 A
•
Quiescent current
120 mA DC
14 collective signal LEDs, some in two colours, 16 LED
pairs, red/yellow, for individual signal indications.
•
Large LC display, fully graphical with menu-guided
operation.
•
Can be loop networked up to 32 units in total.
•
The enclosure has space for emergency power batteries
up to 12 Ah.
•
All settings are carried out via a full graphical interface on
a PC with the MxSysCon con¿guration program.
Battery capacity
External control voltage
Ambient temperature
Relative humidity
(IEC721-3-3)
Enclosure
Dimensions
IP rating (EN60529)
Color
12 Ah internal
21 V - 29.6 V DC
-5°C to +40°C (+23 °F to +104 °F)
max. 95 %
no condensation
Sheet steel 4U
475 x 340 x 200 mm (WxHxD)
18.7 x 13.4 x 7.9 inch (WxHxD)
IP 54
RAL 7035
approx. 15 kg (33.1 lbs)
without modules
Wall-mounted installation
Weight
Mounting
Approvals / marking
Included in delivery
Fire alarm panel with front display, plate, central card and
power supply unit.
Wired ready for the insertion of any modules.
No additional wiring in the ¿re alarm panel required.
Operating instructions, operator's log, installation manual,
drilling template.
P31.301.410 - 2en / 02.13
Not included in delivery
Modules, zone operating panel cards, batteries, report
printer, installation material.
Caution
This ¿re alarm panel must not be put in circulation and used
in countries of the EU.
Fire alarm panel in compliant with EN54-2,
Electrical control devices for gas extinguishing systems according to EN12094-1.
Note
Batteries order separately.
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 1 - 10
Product Sheet | Detecon
Fire alarm and extinguishing control panels
FMZ 5000 base unit
Order no.: 903177
Fire alarm panel FMZ 5000 mod 12
Medium-size base unit from the ¿re alarm panel range
FMZ 5000.
Elegant 19" wall enclosure with front door in niro-coloured
frame. For connecting addressable detectors and
conventional detectors in standard or industrial design.
Activation of remote transmission units for ¿re and fault
signals, data transfer to management systems and control
stations with open interfaces.
Signal indication through large LC display and LEDs,
menu-guided operation using function keys.
Application
For use for pure ¿re detection control or combined ¿re
detection and extinguishing control in medium-scale projects.
Also for controlling of multi-zone extinguishing systems
through redundant hardware.
Technical specifications
Mains voltage
Mains frequency
115 V / 230 V AC -15%, +10%
•
Free selection of functional modules to be used for all
project tasks. Space for up to 44 modules available.
•
Can also be expanded for controlling multi-zone
extinguishing systems with redundant modules.
•
Up to 28 detector loops with 126 detectors each, 176
conventional detector lines for 32 detectors of any design
each.
50 Hz - 60 Hz
Operating voltage
21 V - 29.6 V DC
•
Up to 176 control groups and 176 relays.
Power supply unit
24 V DC / 2.7 A
•
Quiescent current
120 mA DC
14 collective signal LEDs, some in two colours, max. 192
LED pairs, red/yellow, for individual signal indications.
•
Large LC display, full graphical with menu-guided
operation.
•
Can be loop networked up to 32 units.
•
The enclosure has space for emergency power batteries
up to 26 Ah.
•
All settings are de¿ned via a fully graphical interface on a
PC with the MxSysCon con¿guration program.
Battery capacity
External control voltage
Ambient temperature
Relative humidity
(IEC721-3-3)
Enclosure
Dimensions
IP rating (EN60529)
Color
max. 2 x 26 Ah internal
21 V - 29.6 V DC
-5°C to +40°C (+23 °F to +104 °F)
max. 95 %
no condensation
Sheet steel 12U
600 x 604 x 225 mm (WxHxD)
23.6 x 23.8 x 8.9 inch (WxHxD)
IP 54
RAL 7035
approx. 26 kg (57.3 lbs)
without modules
Wall-mounted installation
Weight
Mounting
Approvals / marking
P31.301.410 - 4en / 02.13
Product features
Included in delivery
Fire alarm panel with front display and operating plates,
central card and power supply unit.
Wired ready for the insertion of any modules.
No additional wiring in the ¿re alarm panel is required.
Operating instructions, operator's log, installation manual,
drilling template.
Additional expanded models upon request.
Not included in delivery
Caution
This ¿re alarm panel must not be put in circulation and used
in countries of the EU.
Fire alarm panel in compliant with EN54-2,
Electrical control devices for gas extinguishing systems
according to EN12094-1.
Cable set FMZ 5000 module
904101
Modules, zone operating panel card, front and dummy plates,
batteries, report printer, installation material.
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 1 - 11
Product Sheet | Detecon
Fire alarm and extinguishing control panels
FMZ 5000 base unit
Fire alarm panel FMZ 5000 mod 12
NT5100 3A
Order no.: 908563
Application
Product features
For use for pure ¿re detection control or combined ¿re
detection and extinguishing control in medium-scale projects.
Also for controlling of multi-zone extinguishing systems
through redundant hardware.
•
Free selection of functional modules to be used for all
project tasks. Space for up to 44 modules available.
•
Can also be expanded for controlling multi-zone
extinguishing systems with redundant modules.
Technical specifications
•
Up to 28 detector loops with 126 detectors each, 176
conventional detector lines for 32 detectors of any design
each.
•
•
Up to 176 control groups and 176 relays.
•
Large LC display, fully graphical with menu-guided
operation.
•
•
Can be loop networked up to 32 units.
•
All settings are de¿ned via a fully graphical interface on a
PC with the MxSysCon con¿guration program.
Mains voltage
115 V / 230 V AC ±15%
Mains frequency
50 Hz - 60 Hz
Operating voltage
21 V - 29 V DC
Power supply unit
24 V DC / 3 A
Quiescent current
120 mA DC
Battery capacity
max. 2 x 26 Ah internal
External control voltage
Ambient temperature
Relative humidity
(IEC721-3-3)
Enclosure
Dimensions
IP rating (EN60529)
Speci¿cation according to
Color
Weight
Mounting
21 V - 29 V DC
-5°C to +40°C (+23 °F to +104 °F)
max. 95 %
no condensation
Sheet steel 12U
600 x 604 x 225 mm (WxHxD)
23.6 x 23.8 x 8.9 inch (WxHxD)
IP 54
EN54-2 A1:2006
EN54-4 A2:2006
EN12094-1:2003
RAL 7035
approx. 26 kg (57.3 lbs)
without modules
Wall-mounted installation
Approvals / marking
P31.301.410 - 7en / 02.13
Medium-size base unit from the ¿re alarm panel range
FMZ 5000.
Elegant 19" wall enclosure with front door in niro-coloured
frame. For connecting addressable detectors and
conventional detectors in standard or industrial design.
Activation of remote transmission units for ¿re and fault
signals, data transfer to management systems and control
stations with open interfaces.
Signal indication through large LC display and LEDs,
menu-guided operation using function keys.
G 204124
G 205019
0786-CPD-20843
0786-CPD-20222
14 collective signal LEDs, some in two colours, max. 192
LED pairs, red/yellow, for individual signal indications.
The enclosure has space for emergency power batteries
up to 26 Ah.
Included in delivery
Fire alarm panel with front display and operating plate,
control card and power supply unit.
Wired ready for insertion of any modules.
No additional wiring in the ¿re alarm panel is required.
Operating instructions, operator's log, installation manual,
drilling template.
Additional expanded models upon request.
Not included in delivery
Cableset FMZ 5000 module
904101
Modules, zone operating panel cards, front and dummy
plates, batteries, report printer, installation material.
Note
Alternative power supply units and batteries must be selected
according to the table at the end of the chapter.
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 1 - 12
Product Sheet | Detecon
Fire alarm and extinguishing control panels
FMZ 5000 base unit
Order no.: 910889
Fire alarm panel FMZ 5000 mod 12
BMA AP
Medium-size base unit of the ¿re alarm panel range
FMZ 5000. Elegant 19“ wall enclosure with front door in
niro-coloured frame. Equipped for ¿re detection, monitoring
and control of ¿red detection systems in a maximum of 512
devices in analogue addressable technology and a maximum
of 128 devices in conventional technique.
Signal indication through large LC display and LEDs,
menu-guided operation using function keys.
Application
For use as ¿re detection panel whith optional extension
possibilities.
Technical specifications
Netzspannung
115 V / 230 V AC -15%, +10%
Mains frequency
21 V - 29 V DC
Power supply unit
24 V DC / 5 A
Quiescent current
340 mA DC
Battery capacity
Ambient temperature
Relative humidity
(IEC721-3-3)
Enclosure
Dimensions
IP rating (EN60529)
Speci¿cation according to
Color
2 x 26 Ah internal
21 V - 29 V DC
-5 °C to +40 °C
(+23 °F to +104 °F)
max. 95 %
no condensation
Sheet steel 12U
600 x 604 x 225 mm (WxHxD)
23.6 x 23.8 x 89 inch (WxHxD)
IP 54
EN54-2 A1:2006
EN54-4 A2:2006
EN12094-1:2003
RAL 7035
Weight
approx. 51 kg (112.4 lbs)
Mounting
Wall-mounted installation
Approvals / marking
Connection for remote transmission unit and ¿re brigade
control panel (FBF).
•
Expansion of the ¿re alarm panel is designed for
controlling a ¿re detection system.
•
4 detector loops, 4 conventional detector lines, 4 control
groups, 8 relays with 1 potential-free changeover contact
each.
•
Collective signal LED and 32 individual LED pairs,
red/yellow, for status indications.
•
Large LC display, fully graphical with menu-guided
operation.
•
Emergency power batteries 26 Ah.
0786-CPD-20843
0786-CPD-20222
Included in delivery
Fire alarm panel with front display and operating plate,
1 central card
1 power supply unit 5 A
2 Loop module
1 Remote transmission unit module
1 Conventional detector module
1 Control group module
1 Relay module
1 Power distribution module
2 Zone operating panel cards
2 26 Ah batteries
Wired ready for operation and precon¿gured.
Operating instructions, terminal assignment, operator‘s log,
installation manual. Drilling stencil.
P31.301.410 - 5en / 02.13
G 204124
G 205019
•
50 Hz - 60 Hz
Operating voltage
External control voltage
Product features
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 1 - 13
Product Sheet | Detecon
Fire alarm and extinguishing control panels
FMZ 5000 base unit
Order no.: 910890
Fire alarm panel FMZ 5000 mod 12
LSZ AP
Medium-size base unit of the ¿re alarm panel range
FMZ 5000. Elegant 19“ wall enclouse with front door in nirocoloured frame. Equipped and ready for ¿re detection, monitoring and control for a single-zone extinguishing system in a
maximum of 256 devices in analog addressable technology
and a maximum of 256 devices in conventional technique.
Signal indication through large LC display and LEDs,
menu-guided operation using function keys.
Application
For use as extinguishing control panel in single-zone extinguishing systems whith optional extension possibilities.
•
Expansion of the ¿re alarm panel is designed for
controlling a single-zone extinguishing system.
•
2 detector loops, 8 conventional detector lines, 4 control
groups, 8 relays with 1 potential-free changeover
contact each.
•
Collective signal LED and individual LED pairs,
red/yellow, for status indications.
•
Large LC display, full graphical with menu-guided
operation.
2 x 26 Ah internal,
•
Emergency power batteries 26 Ah.
21 V - 29 V DC
-5 °C to +40 °C
(+23 °F to +104 °F)
max. 95 %
no condensation
Sheet steel 12U
600 x 604 x 225 mm (WxHxD)
23.6 x 23.8 x 89 inch (WxHxD)
IP 54
EN54-2 A1:2006
EN54-4 A2:2006
EN12094-1:2003
RAL 7035
•
The ¿re alarm is precon¿gured and just needs
individual settings.
Technical specifications
Mains voltage
115 V / 230 V AC -15%, +10%
Mains frequency
50 Hz - 60 Hz
Operating voltage
21 V - 29 V DC
Power supply unit
24 V DC / 5 A
Quiescent current
330 mA DC
Battery capacity
External control voltage
Ambient temperature
Relative humidity
(IEC721-3-3)
Enclosure
Dimensions
IP rating (EN60529)
Speci¿cation according to
Color
Weight
approx. 51 kg (112.4 lbs)
Mounting
Wall-mounted installation
Approvals / marking
Included in delivery
Fire alarm panel with front display and operating plate,
1 central card
1 power supply unit 5 A
1 Loop module
2 Conventional detector module
1 Control group module
1 Relay module
1 Power distribution modul
2 Zone operating panel cards
2 26 Ah batteries
Wired ready for operation and precon¿gured.
Operating instructions, terminal assignment, operator‘s log,
installation manual. Drilling stencil.
0786-CPD-20843
0786-CPD-20222
P31.301.410 - 6en / 02.13
G 204124
G 205019
Product features
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 1 - 14
Product Sheet | Detecon
Fire alarm and extinguishing control panels
FMZ 5000 base unit
Fire alarm panel FMZ 5000 mod XL 21U
Order no.: 905454
Base unit from the ¿re alarm panel range FMZ 5000 as
19" version in a wall enclosure with a height of 21U. For
connecting addressable detectors and conventional detectors
in standard or industrial design. Activation of remote
transmission units for ¿re and fault signals, data transfer
to management systems and control stations with open
interfaces. Signal indication through large
LC display and LEDs, menu-guided operation using function
keys.
Application
For use for pure ¿re detection control or combined ¿re
detection and extinguishing control in medium scale projects.
Also control of multi-zone extinguishing systems through
redundant hardware.
Technical specifications
Mains voltage
50 Hz - 60 Hz
Operating voltage
21 V - 29 V DC
Power supply unit
see table
Quiescent current
120 mA DC
Battery capacity
see table
External control voltage
Dimensions
IP rating (EN60529)
Speci¿cation according to
Color
Weight
Mounting
21 V - 29 V DC
-5°C to +40°C (+23 °F to +104 °F)
max. 95 %
no condensation
Sheet steel 21U
600 x 1012 x 373 mm (WxHxD)
23.6 x 39.8 x 14.7 inch (WxHxD)
IP 55
EN54-2 A1:2006
EN54-4 A2:2006
EN12094-1:2003
RAL 7035
approx. 70 kg (154.3 lbs)
without modules
Wall-mounted installation
P31.301.410 - 8en / 01.14
Approvals / marking
G 204124
G 205019
•
Free selection of functional modules to be used for all
project tasks. Space for up to 44 modules available.
•
Can also be expanded for controlling multi-zone
extinguishing systems with redundant processors.
•
Up to 28 detector loops with 126 detectors each,
up to 176 conventional detector lines for 32 detectors of
any design each.
•
Up to 176 control groups and 176 relays.
•
14 collective signal LEDs, some in two colours, max. 352
LED pairs, red/yellow, for individual signal indications.
•
Large LC display, full graphical with menu-guided
operation.
•
Can be loop networked up to 32 units.
•
All settings are de¿ned via a fully graphical interface on a
PC with the MxSysCon con¿guration program.
115 V / 230 V AC -15%, +10%
Mains frequency
Ambient temperature
Relative humidity
(IEC721-3-3)
Enclosure
Product features
0786-CPD-20843
0786-CPD-20222
Included in delivery
Fire alarm panel in 21U wall enclosure ¿tted with front display
and operating plate, central card.
Wired ready for the insertion of any modules. No additional
wiring within the ¿re alarm panel required during expansion.
Operating instructions, operator's log, mounting manual.
Not included in delivery
Cable set FMZ 5000 mod XL module
905113
Modules, zone operating panel card, power supply unit,
dummy front plates, batteries, report printer, installation
material.
Note
Control panel without power supply unit.
The power supply unit and the batteries must be selected
according to the table at the end of the chapter.
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 1 - 15
Product Sheet | Detecon
Fire alarm and extinguishing control panels
FMZ 5000 base unit
Fire alarm panel FMZ 5000 mod XL 31U
Order no.: 905481
Base unit of the ¿re alarm panel range FMZ 5000 as 19"
version in a free-standing enclosure with a height of 31U with
variable depth, width and base dimensions.
For connecting addressable detectors and conventional
detectors in standard or industrial design.
Activation of remote transmission units for ¿re and fault
signals as well as data transfer to management systems and
control stations with open interfaces.
Signal indication through large LC display and LEDs,
menu-guided operation using function keys.
Application
For use for pure ¿re detection control or combined ¿re
detection and extinguishing control in projects up to very
large size. Also control of multi-zone extinguishing systems
through redundant hardware.
Technical specifications
Mains voltage
50 Hz - 60 Hz
Operating voltage
21 V - 29 V DC
Power supply unit
see table
Quiescent current
120 mA DC
Battery capacity
see table
External control voltage
Dimensions
IP rating (EN60529)
Speci¿cation according to
Color
Weight
Mounting
21 V - 29 V DC
-5°C to +40°C (+23 °F to +104 °F)
max. 95 %
no condensation
Sheet steel 31U
800 x 1600 x 600 mm (WxHxD)
(31.5 x 63 x 23.6 inch) (WxHxD)
(H without base)
IP 53
with separately cable gland IP 55
EN54-2 A1:2006
EN54-4 A2:2006
EN12094-1:2003
RAL 7035
approx. 160 kg (352.7 lbs)
without modules
Stand-alone cabinet
P31.301.410- 9en / 02.13
Approvals / marking
G 204124
G 205019
•
Free selection of functional modules to be used for all
project tasks. Space for up to 127 modules available.
•
Can also be expanded for controlling multi-zone
extinguishing systems with redundant modules.
•
Up to 28 detector loops with 126 detectors each, up to
256 conventional detector lines for 32 detectors of any
design each.
•
•
Up to 256 control groups and 512 relays.
•
Large LC display, full graphical with menu-guided
operation.
•
•
Can be loop networked with up to 32 units.
115 V / 230 V AC -15%, +10%
Mains frequency
Ambient temperature
Relative humidity
(IEC721-3-3)
Enclosure
Product features
0786-CPD-20843
0786-CPD-20222
14 collective signal LEDs, some in two colours, max. 432
LED pairs, red/yellow, for individual signal indications.
All settings are de¿ned via a fully graphical interface on a
PC with the MxSysCon con¿guration program.
Included in delivery
Fire alarm panel in free-standing enclosure ¿tted with front
display and operating plate, central card, ¿re alarm control
card.
Wired ready for the insertion of any modules.
No additional wiring within the ¿re alarm panel required for
expansion.
Operating instructions, operator's log, mounting manual.
Not included in delivery
Cable gland 800 mm IP rating IP 55
908504
Cable set FMZ 5000 mod XL module
905113
Modules, zone operating panels, power supply unit,
dummy front plates, batteries, report printer, installation
material.
Note
Control panel without power supply unit.
The power supply unit and the batteries must be selected
according to the table at the end of the chapter.
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 1 - 16
Product Sheet | Detecon
Fire alarm and extinguishing control panels
FMZ 5000 base unit
Fire alarm panel FMZ 5000 mod XL 40U
Order no.: 905041
Base unit from the ¿re alarm panel range FMZ 5000 as 19"
version in a free-standing cabinet with a height of 40U with
variable depth, width and base dimensions and various
different design variants.
For connecting addressable detectors and conventional
detectors in standard or industrial design.
Activation of remote transmission units for ¿re and fault
signals as well as data transfer to management systems and
control stations with open interfaces.
Signal indication through large LC display and LEDs,
menu-guided operation using function keys.
Application
For use for pure ¿re detection control or combined ¿re
detection and extinguishing control in projects up to very
large size. Also control of multi-zone extinguishing systems
through redundant hardware.
Technical specifications
Mains voltage
50 Hz - 60 Hz
Operating voltage
21 V - 29 V DC
Power supply unit
see table
Quiescent current
120 mA DC
Battery capacity
see table
External control voltage
Dimensions
IP rating (EN60529)
Speci¿cation according to
Color
Weight
Mounting
21 V - 29 V DC
-5°C to +40°C (+23 °F to +104 °F)
max. 95 %
no condensation
Sheet steel 40U
800 x 2000 x 600 mm (WxHxD)
(31.5 x 78.7 x 23.6 inch) (WxHxD)
(H without base)
IP 53
with separately cable gland IP 55
EN54-2 A1:2006
EN54-4 A2:2006
EN12094-1:2003
RAL 7035
approx. 190 kg (418.9)
without modules
Stand-alone cabinet
P31.301.410 - 10en / 02.13
Approvals / marking
G 204124
G 205019
•
Free selection of functional modules to be used for all
project tasks. Space for up to 127 modules available.
•
Can also be expanded for controlling multi-zone
extinguishing systems with redundant modules.
•
Up to 28 detector loops with 126 detectors each, up to
256 conventional detector lines for 32 detectors of any
design each.
•
•
Up to 256 control groups and 256 relays.
•
Large LC display, full graphical with menu-guided
operation.
•
•
Can be loop networked with up to 32 units.
115 V / 230 V AC -15%, +10%
Mains frequency
Ambient temperature
Relative humidity
(IEC721-3-3)
Enclosure
Product features
0786-CPD-20843
0786-CPD-20222
14 collective signal LEDs, some in two colours, max. 432
LED pairs, red/yellow, for individual signal indications.
All settings are de¿ned via a full graphical interface on a
PC with the MxSysCon con¿guration program.
Included in delivery
Fire alarm panel in free-standing enclosure ¿tted with front
display and operating plate, control card.
Wired ready for insertion of any modules.
No additional wiring within the ¿re alarm panel required for
expansion.
Operating instructions, operator's log, mounting manual.
Not included in delivery
Cable gland 800 mm IP rating IP 55
908504
Cable set FMZ 5000 mod XL module
905113
Modules, zone operating panels, power supply unit,
dummy front plates, batteries, report printer, installation
material.
Note
Control panel without power supply unit.
The power supply unit and the batteries must be selected
according to the table at the end of the chapter.
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 1 - 17
Product Sheet | Detecon
Fire alarm and extinguishing control panels
FMZ 5000 base unit
Overview of alternative power packs and maximum battery capacity per control panel
FMZ 5000 mod S FMZ 5000 mod 4
FMZ 5000 mod 12
FMZ 5000 mod XL
21 HE
31 HE
40 HE
26 Ah
26 Ah
26 Ah
26 Ah
---
26 Ah
45 Ah
85 Ah
115 Ah and
130 Ah*
12 Ah
26 Ah
---
---
---
NT5000 5 A
(Order no. 901037)
---
---
NT5000 15 A
(Order no. 901038)
---
NT5100 3 A
(Order no. 908452)
---
* Based on two power packs or parallel connection 4 x 65 Ah.
For batteries from 2 x 85 Ah or 4 x 65 Ah, a heavy-duty pivot frame must be used.
Overview of alternative batteries for power packs
Battery 2.2 Ah
(Order no. 236023)
NT5000 5 A
NT5000 15 A
NT5100 3 A
(Order no. 901037) (Order no. 901038) (Order no. 908452)
---
---
Battery 7.2 Ah
(Order no. 902941)
---
---
X
Battery 12 Ah
(Order no. 761677)
X
---
X
Battery 18 Ah
(Order no. 756859)
X
---
X
Battery 26 Ah
(Order no. 132721)
X
X
X
Battery 45 Ah
(Order no. 832386)
---
X
---
Battery 65 Ah
(Order no. 794921)
---
X
---
Battery 85 Ah
(Order no. 801758)
---
X
---
Battery 115 Ah
(Order no. 800775)
---
X
---
P31.301.410en / 01.14
---
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 1 - 18
Product Sheet | Detecon
Fire alarm and extinguishing control panels
FMZ 5000 modules/cards
FMZ 5000 Loop AP XP module
Order no.: 906185
Functional module for use in all design variants of the ¿re
alarm system FMZ 5000.
Includes 2 detector loops for connection of up to 126 devices
each.
Instead of a loop, 2 branches can be connected to the module. Any number of T branches can be connected to each
loop. The loop devices can be ¿re detectors, input/output
modules, control modules for horns and loop couplers for the
operation of conventional detectors in the loop.
For use in potentially explosive atmospheres, IS-detectors
can be connected to the loop via protocol interface and safety
barriers.
Application
Product features
•
For the interface connection of analog addressable detectors and modules with Loop AP protocol.
•
The high loop current enables the operation of multiple
modules and horns in a single loop.
•
All settings of the module, the detectors and the detector
zones are con¿gured using the MxSysCon con¿guration
program.
•
No further adjustment is required.
Technical specifications
Operating voltage (module)
Quiescent current
(module-bus)
Supply current
max. 1440 mA DC
max. 400 mA DC
Loop voltage
27 V DC
Number of detectors per loop
Max. terminal cross-section
Ambient temperature
Relative humidity
(IEC721-3-3)
IP rating (EN60529)
Enclosure
2
126
2.5 mm2 (0.004 square inch)
-5 °C to +40 °C (+23 °F to +104 °F)
max. 95 %
no condensation
IP 20
Polyamide PA6.6, green
Installation position
Mounting
Weight
Dimensions
Total cable length
The module is inserted into the panel with separate powersupply by power distribution module. The power supply and
system communication are connected via plug-in
connections on the module enclosure.
Up to 14 modules can be used in one ¿re alarm panel.
max. 52 mA DC
Loop current
Number of loops
TP31.301.421 - 5en / 01.14
18 V - 30 V DC
For ¿re detection with detectors using loop technology.
System monitoring by connecting switches to addressable
input modules.
Control of ¿re protection devices via dry contacts or monitored via output modules.
Interface connection of monitored zone horns via a horn
module.
For the operation of conventional detectors in the loop, these
are connected to a loop coupler.
Vertical
Mounting rail 35 DIN 46277,
top hat pro¿le
220 g (0.5 lbs)
35 x 99 x 114.5 mm (WxHxD)
1.4 x 3.9 x 4.5 inch (WxHxD)
max. 2000 m (78740 inch)
Included in delivery
Module completely assembled and ready for installation in
the ¿re alarm panel.
Not included in delivery
4 socket terminal strips FKCT 2.5/3-ST
power distribution module
901564
904093
Application in potentially explosive
atmospheres
Only the following barriers are permitted:
Safety barriere IS addressable 24 V
Loop AP protocol interface
901324
901322
Note
If the loops of one loop module are used for ¿re detection or
controlling several extinguishing zones, the loop module AP
XP redundant, order no. 906186 must be used.
Approvals / marking
See panels
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 1 - 19
Product Sheet | Detecon
Fire alarm and extinguishing control panels
FMZ 5000 modules/cards
FMZ 5000 Loop AP XP redundant module
Order no.: 906186
Product features
Functional module for use in all design variants of the ¿re
alarm system FMZ 5000.
The loop module includes two redundant processors for
the operation in multi-zone extinguishing systems in accordance with standards.
Includes 2 detector loops for connection of up to 126 devices
each. Instead of a loop, 2 branches can be connected to the
module. Any number of T branches can be connected to each
loop. The loop devices can be ¿re detectors, input/output
modules, control modules for horns and loop couplers for the
operation of conventional detectors in the loop.
For use in potentially explosive atmospheres, IS-detectors
can be connected to the loop via protocol interface and safety
barriers.
•
Includes redundant processors for the control of the module and the loops.
•
For the interface connection of analog addressable detectors and modules with Loop AP protocol.
•
The high loop current allows the operation of multiple
modules and horns in a single loop.
•
All settings of the module, the detectors and detector
zones are carried out with the MxSysCon con¿guration
program.
•
No further adjustment is required.
Technical specifications
Operating voltage (module)
Quiescent current
(module-bus)
Supply current
max. 85 mA DC
max. 1440 mA DC
Loop current
max. 400 mA DC
Loop voltage
27 V DC
Number of loops
Number of detectors per loop
Max. terminal cross-section
Ambient temperature
Relative humidity
(IEC721-3-3)
IP rating (EN60529)
Enclosure
2
126
2.5 mm2 (0.004 square inch)
-5 °C to +40 °C (+23 °F to +104 °F)
max. 95 %
no condensation
IP 20
Polyamide PA6.6, green
Installation position
TP31.301.421 - 6en / 01.14
18 V - 30 V DC
Mounting
Weight
Dimensions
Total cable length
Vertical
Mounting rail 35 DIN 46277,
top hat pro¿le
220 g (0.5 lbs)
35 x 99 x 114.5 mm (WxHxD)
1.4 x 3.9 x 4.5 inch (WxHxD)
max. 2000 m (78740 inch)
Application
For ¿re detection in several zones of multi-zone extinguishing
systems by means of detectors using loop technology.
System monitoring by connecting switches to addressable
input modules.
Control of ¿re protection devices via dry contacts or monitored via output modules.
Interface connection of monitored zone horns via a horn
module.
For the operation of conventional detectors in the loop, these
are connected to a loop coupler.
The module is inserted into the panel with separate powersupply by power distribution module. The power supply and
system communication are connected via plug-in
connections on the module enclosure.
Up to 14 modules can be used in one ¿re alarm panel.
Included in delivery
Module completely assembled and ready for installation in
the ¿re alarm panel.
Not included in delivery
4 socket terminal strips FKCT 2.5/3-ST
power distribution module
901564
904093
Application in potentially explosive
atmospheres
Only the following barriers are permitted:
Safety barriere IS addressable 24 V
Loop AP protocol interface
901324
901322
Note
For ¿re detection in single-zone extinguishing systems,
the module loop AP XP, order no. 906185 can be used.
Approvals / marking
See panels
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 1 - 20
Product Sheet | Detecon
Fire alarm and extinguishing control panels
FMZ 5000 modules/cards
FMZ 5000 conventional detector module
Order no.: 901773
Functional module for use in all design variants of the ¿re
alarm system FMZ 5000.
Includes 4 closed current monitored detector lines for the
connection of conventional detectors in accordance with the
applicable national regulations.
A detector event is reported via a current increase. Each line
has 4 adjustable thresholds:
quiescent current, wire breakage, short circuit, event.
The voltage of each line can be adjusted separately in the
range of 9 V to 20 V.
All conventional detectors in the Minimax detector range
including the Orbis series can be used with this operating
voltage range, as well as devices from other manufacturers.
Product features
•
Large range of detector types available for in virtue of the
wide adjustment range of the line voltages and current
thresholds.
•
All detectors can be operated with two-detector
coincidence and all zones with two-zone coincidence.
•
All settings are con¿gured using the MxSysCon
con¿guration program.
•
No further adjustment is required.
Operating voltage
19 V - 29 V DC
Quiescent current
2 mA - 50 mA DC
Alarm current
Terminating resistor
Number of detectors per
line
Max. terminal cross-section
Ambient temperature
Relative humidity
(IEC721-3-3)
IP rating (EN60529)
Enclosure
9 V - 20 V DC
Module completely assembled and ready for installation in
the panel.
Not included in delivery
4 socket terminal strips FKCT 2.5/3-ST
Mounting
Weight
Dimensions
901564
5 mA - 80 mA DC
1.8 k:
32 pieces (VdS)
2.5 mm2 (0.004 square inch)
-5 °C to +40 °C (+23 °F to +104 °F)
max. 95 %
no condensation
IP 20
Note
The simultaneous operation of detectors of the Orbis series
with other series on one conventional module is not permitted
due to the different characteristics of the detectors.
Each module may be operated only with Minimax detectors
or with detectors of Orbis series as well as with detector of
other manufactures. Manual call points and monitoringcontests can be freely mixed with all other detector types.
Polyamide PA6.6, green
Installation position
P31.301.421 - 7en / 02.13
For connection of any type of conventional detectors or
manual call points in standard or industrial design.
System monitoring takes place by connecting appropriate
monitoring switches with dry contacts.
The module is inserted into the panel without additional
wiring. The power supply and system communication are
connected via plug-in connections on the module enclosure.
Up to 64 modules can be used in one ¿re alarm panel.
Included in delivery
Technical specifications
Line voltage
Application
Vertical
Mounting rail 35 DIN 46277,
top hat pro¿le
120 g (0.26 lbs)
17.5 x 99 x 114.5 mm (WxHxD)
0.7 x 3.9 x 4.5 inch (WxHxD)
Approvals / marking
See panels
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 1 - 21
Product Sheet | Detecon
Fire alarm and extinguishing control panels
FMZ 5000 modules/cards
FMZ 5000 control group module
Order no.: 901673
Functional module for use in all design variants of the ¿re
alarm system FMZ 5000.
Includes 4 control lines for the monitoring and control of ¿re
protection devices.
The line to the devices is monitored for wire breakage and
short circuits.
The connected ¿re protection devices are also monitored to
verify that they are present and in proper condition.
Application
Product features
•
Up to 3 devices can be monitored simultaneously by one
control group.
•
Control groups can be time-controlled with delays,
pulse controlled or continuously controlled.
•
All settings are con¿gured using the MxSysCon con¿guration program.
•
No furher adjustment work is required.
Module completely assembled and ready for installation in
the ¿re alarm panel.
Operating voltage
19 V - 29 V DC
Quiescent current
25 mA DC
External control groups
Output current
Control
Max. terminal cross-section
Ambient temperature
Relative humidity
(IEC721-3-3)
IP rating (EN60529)
Enclosure
4, quiescent current monitored
21 V - 29 V DC
1 A, continuous load
Time-controlled, continuous,
pulse, inverted
2.5 mm2 (0.004 square inch)
Not included in delivery
4 socket terminal strips FKCT 2.5/3-ST
Mounting
Weight
Dimensions
901564
Spare parts
Fuse 2 A / 125 V
784352
Note
If the module is used to trigger horns or extinguishing devices
in multi-zone extinguishing systems, a separate control group
module must be used for each extinguishing zone.
-5 °C to +40 °C (+23 °F to +104 °F)
max. 95 %
no condensation
IP 20
Polyamide PA6.6, green
Installation position
P31.301.421 - 8en / 01.14
The module is inserted into the panel with separate powersupply by power distribution module. The power supply and
system communication are connected via plug-in connections
on the module enclosure.
Up to 64 modules can be used in one ¿re alarm panel.
Included in delivery
Technical specifications
Number of control groups
For monitoring and control of e.g. valves, solenoids or horns
in extinguishing systems or other ¿re protection devices.
Vertical
Mounting rail 35 DIN 46277,
top hat pro¿le
100 g (0.2 lbs)
17.5 x 99 x 114.5 mm (WxHxD)
0.7 x 3.9 x 4.5 inch (WxHxD)
Approvals / marking
See panels
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 1 - 22
Product Sheet | Detecon
Fire alarm and extinguishing control panels
FMZ 5000 modules/cards
FMZ 5000 8 relay module
Order no.: 901595
Functional module for use in all design variants of the ¿re
alarm system FMZ 5000.
The module has 8 relays, each with a dry contact.
An activated relay is indicated by a red status LED.
A separate relay card with up to 8 additional relays can be
connected via a plug connector strip. Control happens via
open collector outputs parallel to the relays in the module.
This allows relays with higher switching voltages or currents
to be used.
Product features
Application
•
Relays are time-controlled – with the option of delays, pulse
control or continuous control.
•
All settings are con¿gured using the MxSysCon con¿guration program.
•
No further adjustment work is required.
Included in delivery
Technical specifications
Operating voltage
19 V - 29 V DC
Quiescent current
10 mA DC
Current per relay
10 mA
Number of relays
8 TQ
Contacts per relay
Contact load
Max. switching capacity
Control
Max. terminal cross-section
Ambient temperature
Relative humidity
(IEC721-3-3)
IP rating (EN60529)
Enclosure
1 changeover, dry
1 A / 30 V DC, 0.5 A / 125 V AC
30 W / 62.5 VA
Time-controlled, continuous,
pulse, inverted
2.5 mm2 (0.004 square inch)
Module completely assembled and ready for installation in
the ¿re alarm panel.
Not included in delivery
8 socket terminal strips FKCT 2.5/3-ST
Relay card 8 TQ
Relay card 8
Mounting
Weight
Dimensions
901564
800843
802587
Note
The contacts of the relays in the module are not suitable for
the switching of 230/110 V AC mains voltage.
-5°C to +40 °C (+23 °F to +104 °F)
max. 95 %
no condensation
IP 20
Polyamide PA6.6, green
Installation position
P31.301.421 - 9en / 02.13
For the dry-contact control of e.g. ¿re protection devices,
graphic annunciators, ventilation system shutdown or for
general signal transfer.
The module is inserted into the panel without additional
wiring. The power supply and system communication are
connected via plug-in connections on the module enclosure.
Up to 64 modules can be used in one ¿re alarm panel.
Vertical
Mounting rail 35 DIN 46277,
top hat pro¿le
170 g (0.4 lbs)
35 x 99 x 114.5 mm (WxHxD)
1.4 x 3.9 x 4.5 inch (WxHxD)
Approvals / marking
See panels
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 1 - 23
Product Sheet | Detecon
Fire alarm and extinguishing control panels
FMZ 5000 modules/cards
FMZ 5000 Impulse valve reset module
Order. no.: 908324
Functional module for use in all design variants of the ¿re
alarm system FMZ 5000.
The module contains all connections and functions for controlling and resetting an impulse valve in water extinguishing
systems with 24 V DC operating voltage.
The operating positions of the valve are represented by two
LEDs. The order to reset the valve is given via an external
button connected to the module or a relay contact.
Can be installed in the extinguishing control panel or in a
separate housing with a mounting rail.
Application
Product features
•
Valve can also be closed via an external button.
•
The open status of the valves can be displayed on a
connectable status display or forwarded via a relay.
•
Space-saving setup due to narrow module enclosure on
a mounting rail.
The module is used for controlling impulse valves in water
extinguishing systems.
The impulse valve contains two coils, one for opening and
one for closing the valve. If the valve remains in the last position obtained in the open or close procedure when the power
supply is switched off, the respective coils can be controlled
in impulse mode.
Included in delivery
Module completely assembled and ready for installation in
the ¿re alarm panels with socket terminals.
Technical specifications
Operating voltage
Quiescent current
Permissible current
open valve
Permissible current
close valve
External display voltage
Permissible current
external display
Max. terminal cross-section
Ambient temperature
Ambient temperature
storage
Relative humidity
(IEC721-3-3)
IP rating (EN60529)
Enclosure
20 mA DC
” 1 A DC
Not included in delivery
Control group module, remote control buttons, external displays, forwarding relay.
” 1 A DC
24 V DC
” 1 A DC
Connection / mounting
DIN hat rail as per IEC/EN 60715. Module can also be used
in separete housing outside the extinguishing control panel.
2.5 mm2 (0.004 square inch)
-5 °C to +40 °C (+23 °F to +104 °F)
-10 °C to +70 °C (+14 °F to +158 °F)
max. 95 %
no condensation
IP 20
Note
The module does not monitor the supply to the open coil.
Control group module order no. 901673 can be used to monitor the impulse valve open coil.
Polyamid PA6.6, green
Installation position
Mounting
Weight
P31.301.421 - 10en / 02.13
19 V - 27 V DC
Dimensions
vertical
Mounting rail 35 DIN 46277,
top hat pro¿le
150 g (0.3 lbs)
17.5 x 93 x 108 mm (BxHxT)
0.7 x 3.9 x 4.5 inch (WxHxD)
Approvals / marking
See panels
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 1 - 24
Product Sheet | Detecon
Fire alarm and extinguishing control panels
FMZ 5000 modules/cards
FMZ 5000 ground fault module
Order no.: 800096
Function module for monitoring and signalling a ground fault.
The module monitors in a connected device the galvanic separation between protective earth (PE) and all secondary DC
voltages inclusive of the ground wire as reference potential.
Application
Product features
•
Ground fault monitoring of lines carring direct current.
•
Function test by means of test button.
•
Transmission through Àoating contact and open collector
output.
•
Easy installation in alarm systems, as the event and
terminating resistor are integrated for connection of a
conventional detector group.
Technical specifications
Operating voltage
Quiescent current
Current in case of earth fault
Test voltage (IEC950)
approx. 7 mA DC
approx. 15 mA DC
approx. 620 kOhm
Response threshold
approx. 50 kOhm
Max. terminal cross-section
max. 20 —F
2.5 mm2 (0.004 square inch)
Ambient temperature
-5 °C to +40 °C (+23 °F to +104 °F)
Storage temperature
Relative humidity
(IEC721-3-3)
IP rating (EN60529)
-10 °C to +50 °C (+14 °F to +122 °F)
max. 95 %
no condensation
IP 20
Enclosure
Included in delivery
Module completly assembled and ready for the installation in
the ¿re alarm panels, inclusive connection and commissioning instructions.
Not included in delivery
Test button.
500 V AC, 700 V DC
Resistance 0 V - PE
Terminal capacitance
Note
As the GND lines of detector groups in explosive areas with
the ignition protection type intrinsically safe Ex i are connected with PE via an upstream Zener barrier, use of the module
is not possible.
Polyamide PA6.6, green
Installation position
Mounting
P31.301.421 - 11en / 02.13
18 V - 30 V DC
The ground fault module is ¿tted in the device to be monitored or in its vicinity on a mounting rail. If the resistance
between the DC voltage potentials in the device and the protective earth should drop below a certain value, then an open
collector output is triggered for retransmission.
For ¿re detection control panels, e.g. the cables of detector groups, triggering of horns and supply voltages can be
monitored.
Weight
Dimensions
Vertical
Mounting rail 35 DIN 46277,
top hat pro¿le
67 g (0.15 lbs)
19x81x70 mm (WxHxD)
1.4 x 3.9 x 4.5 inch (WxHxD)
Approvals / marking
See panels
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 1 - 25
Product Sheet | Detecon
Fire alarm and extinguishing control panels
FMZ 5000 modules/cards
FMZ 5000 power distribution module
Order no.: 904093
Module for use in all design variants of the ¿re alarm system
FMZ 5000.
It includes protection elements for diverting overvoltage to the
protective earth.
Application
Product features
•
6 terminals each to take 24V and GND for the supply of
connected devices.
•
Protects connected devices from transient overvoltages.
•
No settings on the module are required.
The power distribution module is used for the star-con¿guration power supply of modules with high output currents e.g.
the control group and Loop module AP XP.
It also diverts transient overvoltages from the modules to the
protective earth.
Normally a power distributor is ¿tted at the end of a module
row.
One module can be set per module row (via mounting rail).
Technical specifications
Operating voltage
Output current
Max. terminal cross-section
Ambient temperature
Relative humidity
(IEC721-3-3)
IP rating (EN60529)
Enclosure
19 V - 29 V DC
4 A DC
2.5 mm2 (0.004 square inch)
-5 °C to +40 °C (+23 °F to +104 °F)
max. 95 %
no condensation
IP 20
Polyamide PA6.6, green
Installation position
Mounting
Weight
Dimensions
Vertical
Mounting rail 35 DIN 46277,
top hat pro¿le
85 g (0.2 lbs)
22.5 x 99 x 114.5 mm (WxHxD)
0.9 x 3.9 x 4.5 inch (WxHxD)
Included in delivery
Module completely assembled and ready for installation in
the ¿re alarm panel.
Not included in delivery
4 socket terminal strips FKCT 2.5/3-ST
90 1564
Note
If the power distribution module is used to supply external
devices directly, each outgoing 24 V supply must be fuseprotected.
The module is not a substitute for surge arrestors necessary
for lightning protection.
Approvals / marking
P31.301.421 - 12en / 01.14
See panels
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 1 - 26
Product Sheet | Detecon
Fire alarm and extinguishing control panels
FMZ 5000 modules/cards
FMZ 5000 reflex module
Order no.: 906262
Functional module for use in all design variants of the ¿re
alarm system FMZ 5000.
The reÀex module contains all components for Àame or spark
detection, extinguishing and monitoring for 2 extinguishing
zones where very fast ¿re detection and virtually instantaneous extinguishing are of particular importance.
Conventional spark or Àame detectors can be connected to
conventional detector technology.
All connected detectors and extinguishing components
and their wiring are monitored for wire breakage and short
circuits.
In addition, fault signals from self-monitoring detectors are
processed and displayed.
Application
Product features
•
Instant ¿re detection and extinguishing for two mutually
independent extinguishing zones.
•
Display of ¿re alarm messages and extinguishing events
accurate to the millisecond.
•
Spark counter for maximum number or average of detected sparks per unit of time, in order to e.g. carry out
machine shutdowns.
Technical specifications
Operating voltage
19 V - 27 V DC
Quiescent current
30 mA DC
Number of detector lines
2
Number of control groups
Number of
monitoring lines
2
No. of detectors per line
Maximum current
per control group
Functions monitored
Line monitoring
Ambient temperature
Relative humidity
(IEC721-3-3)
IP rating (EN60529)
Enclosure
8 spark detectors
4 Àame detectors
2.6 A DC
Included in delivery
Module completely assembled and ready for installation in
the ¿re alarm panel.
Not included in delivery
12 socket terminal strips FKCT 2.5/3-ST
Mounting
Weight
Dimensions
90 1564
Note
Up to 40 modules can be used in one ¿re alarm panel.
No extinguishing, extinguishing time too
long, leakage, blockage, detector fault
All lines for wire breakage,
short circuits
-5 °C to +40 °C (+23 °F to +104 °F)
max. 95 %
no condensation
IP 20
Polyamide PA6.6, green
Installation position
P31.301.421 - 14en / 01.14
4
The reÀex module is used for ¿re protection in pneumatic
conveying systems, painting facilities, machine tools or wherever there is a risk of rapidly spreading ¿res. Instantaneous
ejection of combustible material is likewise possible.
In painting facilities, Àames caused by high voltage
Àashovers are extinguished immediately by cutting off the
supply of paint and applying extinguishing agents through the
paint spray nozzles.
In machine tools, the machining process is monitored and in
the event of the machined material or cooling agent catching
¿re, the tool is stopped immediately and extinguishing can be
initiated instantly.
Vertical
Mounting rail 35 DIN 46277,
top hat pro¿le
290 g (0.6 lbs)
53 x 99 x 114.5 mm (WxHxD)
2.1 x 3.9 x 4.5 inch (WxHxD))
Approvals / marking
See panels
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 1 - 27
Product Sheet | Detecon
Fire alarm and extinguishing control panels
FMZ 5000 modules/cards
FMZ 5000 spark test 8 module
Order no.: 906980
Functional module for use in all design variants of the ¿re
alarm system FMZ 5000.
The spark test module contains 8 outputs each for connecting one test actuator. The actuators can be manually triggered or triggered at freely con¿gurable test times by the
spark test module, with multiple tests possible in one day.
For testing, the actuator emits a light pulse of de¿ned intensity. The intensity can be manually pre-set or automatically
learned by the system.
When triggering, the module checks whether the test actuator
is connected. The test actuators can be assigned during con¿guration to any spark detector zone in the ¿re alarm panel.
Application
Product features
•
Function testing while the monitored facility is in operation, for up to eight spark detector zones.
•
Individual test conditions for each detector zone, because test light intensity can be manually pre-set or can
be learned independently by the system during operation.
•
The spark test is carried out without interrupting operation of the monitored facility.
•
All settings are carried out using the MxSysCon con¿guration program.
Technical specifications
19 V - 27 V DC
Quiescent current
20 mA DC
Max. test current
Functions monitored
Max. terminal cross-section
Ambient temperature
Relative humidity
(IEC721-3-3)
IP rating (EN60529)
Enclosure
Module completely assembled and ready for installation in
the ¿re alarm panel.
8
3 A DC
Connection and functioning
of the test actuator
2.5 mm2 (0.004 square inch)
8 socket terminal strips FKCT 2.5/3-ST
Mounting
Weight
Dimensions
90 1564
Note
The module contains all required components and no other
modules are needed for operation.
The module can only be used in connection with spark detector lines of ReÀex modules.
-5 °C to +40 °C (+23 °F to +104 °F)
max. 95 %
no condensation
IP 20
Polyamide PA6.6, green
Installation position
P31.301.421 - 15en / 01.14
Included in delivery
Not included in delivery
Operating voltage
Number of test actuators
The spark test module 8 is used for testing spark detectors
during ongoing operation of the monitored production facility.
The test actuators are installed opposite the spark detectors.
The test is perfectly adapted to practical requirements, as the
light pulses need to be sent and detected through the Àow of
material during operation of the facility.
Any light pulses not detected by the spark detector are
reported as a fault. The detected light pulse can also trigger
extinguishing, if desired.
Up to 8 modules can be used in one panel.
Vertical
Mounting rail 35 DIN 46277,
top hat pro¿le
160 g (0.3 lbs)
35 x 99 x 114.5 mm (WxHxD)
1.4 x 3.9 x 4.5 inch (WxHxD)
Approvals / marking
See panels
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 1 - 28
Product Sheet | Detecon
Fire alarm and extinguishing control panels
FMZ 5000 modules/cards
FMZ 5000 MxNet module
Order no.: 904877
Functional module for use in all design variants of the ¿re
alarm systems FMZ 5000, as well as mimic panels and
operating panels.
Allows devices to be connected in a line-redundant loop
network.
Communication with the connected devices takes place via a
serial interface in RS232 standard.
All data lines are continuously monitored. In the event of line
faults in the network, line redundancy means that the functions of the devices are not affected.
The module is supplied with power by the networked device.
Application
Product features
•
Communication to the networked devices uses the MX2
protocol in all versions.
•
Up to 32 devices can be networked in a ring.
•
No adjustment work is required.
Technical specifications
Included in delivery
Operating voltage
19 V - 29 V DC
Quiescent current
58 mA DC
Outputs
COM1 RS232 SUB-D socket
Path 1 RS485 modular terminal
Path 2 RS485 modular terminal
Max. terminal cross-section
Ambient temperature
Relative humidity
(IEC721-3-3)
IP rating (EN60529)
Enclosure
2.5 mm2 (0.004 square inch)
-5 °C to +40 °C (+23 °F to +104 °F)
max. 95 %
no condensation
IP 20
Polyamide PA6.6, green
Installation position
Mounting
Weight
Dimensions
The module enables a device to communicate with other
devices in a loop network. The signals from the devices can
be displayed at several central control points. Likewise, commands to the devices are possible from different points in the
network and from outside the network (control stations).
Only one module can be used for one network participant.
Vertical
Mounting rail 35 DIN 46277,
top hat pro¿le
200 g (0.4 lbs)
35 x 99 x 114.5 mm (WxHxD)
1.4 x 3.9 x 4.5 inch (WxHxD)
Module completely assembled and ready for installation in
the ¿re alarm panel.
Note
All parameters can be set using jumpers.
Module is precon¿gured by jumpers.
Alternatively the module and the network can be con¿gured
centrally using the con¿guration program "MxNet.exe".
Use of the module in a FMZ 5000 ¿red detection control
panel requires in addition fail the use of a
module SIO1
903466
or
module SIO3
903467
The module must be placed directly to the right of the SIO
module. Activation is done via the R232 interface by means
of a ribbon cable.
Approvals / marking
P31.301.421 - 16en / 02.13
See panels
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 1 - 29
Product Sheet | Detecon
Fire alarm and extinguishing control panels
FMZ 5000 modules/cards
FMZ 5000 WEBmodule N cpl.
Order no.: 914365
Function module for installation into versions mod 12 and
mod XL of the FMZ 5000 ¿re alarm system.
The module is intended for the communication with a ¿re
alarm panel via the TCP/IP protocol.
It contains an interface according to the RS232 standard
for communication with the control panel over module SIO1
(Order no.: 903466) or SIO3 (Order no.: 903467) via the Mx2
protocol.
The connection of the IP network occurs via patch panel to
the Ethernet interface with a RJ-45 female connector.
Application
Product features
•
Remote polling messages and statuses of ¿re
detection control panels.
•
Display of the messages and statuses in a Web browser.
•
Messages can be served to a remote FTP server.
•
For better evaluation, messages can be repeatedly
¿ltered.
•
Option to use time of time synchronization by NTP
Timeserver.
Technical specifications
Operating voltage
19 V - 28 V DC
Quiescent current
80 mA at 24 V DC
Rated current
Storing temperature
115 mA at 24 V DC
1 RS232
1 Ethernet
-40 °C to +85 °C (-40 °F to +185 °F)
Ambient temperature
Relative humidity
(IEC721-3-3)
IP rating (EN60529)
-0 °C to +65 °C (+32 °F to +149 °F)
max. 90 %
no condensation
IP 20
Data interfaces
Enclosure
Polyamide PA6.6, green
Installation position
Mounting
Weight
P31.301.421 - 21en / 03.13
Dimensions
vertical
Mounting rail 35 DIN 46277,
top hat pro¿le
162 g (0.35 lbs)
52 x 99 x 114 mm (WxLxH)
2.1 x 3.9 x 4.5 inch (WxLxH)
The messages transmitted per Web browser by a ¿re alarm
panel to a PC can be displayed and stored via WEBmodule
from any location.
Time synchronization procedures between ¿re alarm panel
and WEBmodule are possible.
These remote diagnostics optimal scheduling of service
interventions and increased availability of the ¿re detection
system.
Included in delivery
Module ready for installation into the control panel.
SIO-Adapter FMZ WEBmodule
(Connection SIO-Module WEBmodule)
Patch Panel
Cabel Patch cabel CAT6 1.0 m (39 inch)
909409
914347
914349
Note
Use a CAT5 or higher category cable for ¿eld network connection on the patch panel.
In order to preserve electromagnetic compatibility the direct
interconnection between WEBmodule and ¿eld network
installations is not permitted.
Only use the equipment supplied to connect the WEBmodule
via the provided equipment (patch cable, patch panel) to the
¿eld network installation.
Max. cable length for the RS232 interface 10 m (390 in).
Any unauthorized access to the control panel must be prevented by suitable IT protection measures to be taken by the
customer.
Approvals
See panels
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 1 - 30
Product Sheet | Detecon
Fire alarm and extinguishing control panels
FMZ 5000 modules/cards
FMZ 5000 WEBmodule S cpl.
Order no.: 914366
The version WEBmodule S can send switching commands
to the connected control panel (deactivates and activates
detectors and groups, revision mode, user reset).
P31.301.421 - 21en / 03.13
Otherwise like Order no.: 914365
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 1 - 31
Product Sheet | Detecon
Fire alarm and extinguishing control panels
FMZ 5000 modules/cards
FMZ 5000 remote transmission unit module
Order no.: 901969
Functional module for use in all design variants of the ¿re
alarm system FMZ 5000.
Includes monitoring and control for 2 remote transmission
units (RTU).
Each RTU can be used to transmit either ¿re or fault signals.
In addition
- a ¿re brigade control panel (FBF) in acc. with DIN 14661
- a ¿re brigade key depot (FSD) in accordance with German
standard VdS 2105 can be connected using adapter.
Application
Product features
•
For interface connection with two remote transmission
units for ¿re or fault signals.
•
Control can be pulsed or continuous.
•
All settings of the module and the remote transmission
units are carried out with the MxSysCon con¿guration
program.
•
No adjustment work is required.
Technical specifications
Operating voltage
19 V - 29 V DC
Quiescent current
25 mA DC
Outputs
2 RTUs, ¿re / fault
1 ¿re brigade control panel
For monitoring and controlling 2 remote transmission units
for ¿re or fault signals to the ¿re brigade or service points.
If a ¿re brigade control panel is connected, the module
controls all the displays on the display panel and polls the
operator controls.
With a ¿re brigade key depot connected, the door opener is
activated after a ¿re brigade call has been issued and the
position of the door and the presence of the deposited key is
monitored.
A maximum of one module can be used in one ¿re alarm
panel.
Included in delivery
Module completely assembled and ready for installation in
the ¿re alarm panel.
Not included in delivery
2 socket terminal strips FKCT 2.5/4-ST
901565
1 ¿re brigade key depot
Output voltage
24 V DC
Output current
1 A per remote transmission unit
Control
Continuous, pulsed
Max. terminal cross-section
Ambient temperature
Relative humidity
(IEC721-3-3)
IP rating (EN60529)
Enclosure
-5 °C to +40 °C (+23 °F to +104 °F)
max. 95 %
no condensation
IP 20
Fuse 0.5 A/125 V
781223
Note
When activating a key depot a suitable adapter must be used
as well.
Polyamide PA6.6, green
Installation position
Mounting
P31.301.421 - 17en / 01.14
2.5 mm (0.004 square inch)
2
Spare parts
Weight
Dimensions
Vertical
Mounting rail 35 DIN 46277,
top hat pro¿le
200 g (0.4 lbs)
45 x 99 x 114.5 mm (WxHxD)
1.8 x 3.9 x 4.5 inch (WxHxD)
Approvals / marking
See panels
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 1 - 32
Product Sheet | Detecon
Fire alarm and extinguishing control panels
FMZ 5000 modules/cards
FMZ 5000 SIO1 module
Order no.: 903466
Functional module for use in all design variants of the ¿re
alarm system FMZ 5000.
Includes a serial communication channel in RS232 standard.
Preferred for data transmission to an Webmodule, a MxNet
module or a report printer.
The module status is indicated by 3 LEDs.
Product features
Application
•
An RS232-standard serial interface is connected to an
SUB-D socket.
•
Baud rates adjustable from 300 to 115200 baud.
•
All settings of the module, the application and the
communication parameters are de¿ned using with the
MxSysCon con¿guration program.
For serial data transmission in RS232 standard.
When using the Minimax data protocol MX2, all signals from
the ¿re alarm panel can be sent to control stations or visualisation programs and commands can be received from them.
Up to 3 modules can be used in one ¿re alarm panel.
Technical specifications
Operating voltage
19 V - 29 V DC
Quiescent current
42 mA DC
Outputs
COM1 RS232 SUB-D socket
Max. terminal cross-section
Ambient temperature
Relative humidity
(IEC721-3-3)
IP rating (EN60529)
Enclosure
2.5 mm2 (0.004 square inch)
-5 °C to +40 °C (+23 °F to +104 °F)
max. 95 %
no condensation
IP 20
Included in delivery
Module completely assembled and ready for installation in
the ¿re alarm panel.
Not included in delivery
SUB-D plug, 9-pin
Note
The interface is not opto-isolated.
If devices outside the ¿re alarm panel system are connected,
these must be opto-isolated using a separate converter.
Polyamide PA6.6, green
Installation position
Mounting
Weight
Dimensions
Vertical
Mounting rail 35 DIN 46277,
top hat pro¿le
100 g (0.2 lbs)
22.5 x 99 x 114.5 mm (WxHxD)
0.9 x 3.9 x 4.5 inch (WxHxD)
Approvals / marking
P31.301.421 - 18en / 01.14
See panels
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 1 - 33
Product Sheet | Detecon
Fire alarm and extinguishing control panels
FMZ 5000 modules/cards
FMZ 5000 SIO3 module
Order no.: 903467
Functional module for use in all design variants of the ¿re
alarm system FMZ 5000.
Includes a serial communication channel in RS232 standard plus two serial communication channels in RS422 / 485
standard,
One RS422 / 485 channel is opto-isolated for interface connection with devices with an external power supply.
The module status is indicated by 9 LEDs.
Application
Product features
•
The RS232 serial interface is connected to a 9-pin
SUB-D socket.
•
The RS422 / 485 serial interfaces (one opto-isolated) are
connected to series terminal.
•
Baud rates are adjustable from 300 to 115200.
•
All settings of the module, the communication parameters and the application are de¿ned using with the
MxSysCon con¿guration program.
Operating voltage
19 V - 29 V DC
Quiescent current
58 mA DC
Max. terminal cross-section
Ambient temperature
Relative humidity
(IEC721-3-3)
IP rating (EN60529)
Enclosure
COM1 RS232 SUB-D socket
COM2 RS422 / RS485
opto-isolated series terminal
COM3 RS422 / RS485
series terminal
2.5 mm2 (0.004 square inch)
-5 °C to +40 °C (+23 °F to +104 °F)
max. 95 %
no condensation
IP 20
Not included in delivery
SUB-D plug, 9-pin
4 socket terminal strips FKCT 2.5/4-ST
Mounting
Weight
Dimensions
901565
Note
Slide switches are used to switch over from RS422 to RS485
and to activate the bus terminating resistor.
Only use opto-isolated interfaces for data transmission to
external devices or arrange for separate opto-isolation.
The RS485 interface cannot be used for data transfer with
MX 2 protocol.
Polyamide PA6.6, green
Installation position
P31.301.421 - 19en / 01.14
Included in delivery
Module completely assembled and ready for installation in
the ¿re alarm panel.
Technical specifications
Outputs
For serial data transmission in RS232, RS422 or RS485
standard.
When using the Minimax data protocol MX2, all signals from
the ¿re alarm panel can be sent to control stations or visualisation programs and commands can received from them.
Devices with their own power supply can be connected directly to the opto-isolated communication channel.
Up to 2 modules or a total of 6 data channels can be used in
one ¿re alarm panel.
Vertical
Mounting rail 35 DIN 46277,
top hat pro¿le
190 g (0.4 lbs)
45 x 99 x 114.5 mm (WxHxD)
1.8 x 3.9 x 4.5 inch (WxHxD)
Approvals / marking
See panels
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 1 - 34
Product Sheet | Detecon
Fire alarm and extinguishing control panels
FMZ 5000 modules/cards
FMZ 5000 Modbus module
Order no.: 904566
Functional module for use in all design variants of the ¿re
alarm system FMZ 5000.
The module includes an serial interface RS422 standard for
communication using the Modbus protocol.
It supports the Modbus RTU format.
The Modbus module is always the Modbus slave and must
be queried by a Modbus master.
Each slave can be assigned an address in the range of 1-99.
Product features
Application
•
All parameters for the transmission of data to a Modbus
master are con¿gurable.
•
Communication to the Modbus master can be point to
point.
•
All settings are de¿ned using the MxSysCon con¿guration program.
•
No adjustment work is required.
Included in delivery
Technical specifications
Operating voltage
19 V - 29 V DC
Quiescent current
58 mA DC
Outputs
Max. terminal cross-section
Ambient temperature
Relative humidity
(IEC721-3-3)
IP rating (EN60529)
Enclosure
Mounting
Weight
Dimensions
P31.301.421 - 20en / 02.13
COM1 RS232 SUB-D socket
COM2 RS422
opto-isolated modular terminal
2.5 mm2 (0.004 square inch)
-5 °C to +40 °C (+23 °F to +104 °F)
max. 95 %
no condensation
IP 20
Polyamide PA6.6, green
Installation position
For the transmission of signals and system states from the
FMZ 5000 ¿re alarm panel to a control station (Modbus
master) via the Modbus RTU protocol.
Operations such as isolations or resets are also possible
from the control station to the panel.
Using separate converter modules connected in series,
the transmission can also be carried out using other ¿eld bus
protocols (e.g. Pro¿bus via adapter).
A maximum of 2 Modbus module can be used in one ¿re
alarm panel.
Vertical
Mounting rail 35 DIN 46277,
top hat pro¿le
200 g (0.4 lbs)
45 x 99 x 114.5 mm (WxHxD)
1.8 x 3.9 x 4.5 inch (WxHxD)
Module completely assembled and ready for installation in
the ¿re alarm panel.
Not included in delivery
4 socket terminal strips FKCT 2.5/4-ST
901565
Note
The use of the Modbus module is always subject to greatly
differing, project-speci¿c requirements. Therefore the required range of functions and all ancillary conditions must be
de¿ned at an early stage with all project participants and the
parties responsible for the modbus master.
If your project requires an RS458 interface, use the Modbus
RS458 (906853) module. The RS232 interface is not suitable
for Modbus communication
Approvals / marking
See panels
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 1 - 35
Product Sheet | Detecon
Fire alarm and extinguishing control panels
FMZ 5000 modules/cards
FMZ 5000 Modbus RS485 module
Order no.: 906853
Product features
The module uses an RS485 serial interface for communication by means of a Modbus protocol.
Several Modbus modules can be interconnected in bus
operation.
Technical specifications
COM1 RS232 SUB-D socket
COM2 RS485
opto-decoupled modular terminal
If an RS422 interface is required in the project, the module
Modbus (904566) must be used. The RS232 interface is not
provided for Modbus communication.
Otherwise as Order no. 904566
P31.301.421 - 20en / 02.13
Outputs
Note
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 1 - 36
Product Sheet | Detecon
Fire alarm and extinguishing control panels
FMZ 5000 modules/cards
24 V to 9 V voltage converter module
Order no.: 908471
Function module for use of all detectors with 9 V mains voltage (e.g. Minimax detectors) on any ¿re alarm control panels.
The module lowers the voltage to a set value and transfers
the standby- and alarm current of the connected detectors.
When using detectors for hazard areas with a risk of explosion the requirements of detectors protected against explosion
must be observed.
When using detectors with the „Intrinsic Safety“ protection
type the prescribed safety barriers are to be used.
Application
Product features
•
Fixed voltage regulation to 9.5 V output voltage.
•
Space-saving assembly via narrow module housing on
mounting rail.
Technical specifications
Operating voltage
Current consumption
Output voltage
Short circuit disconnection
output
Fuse output
Conductor cross-section
15 V - 28 V DC
0.05 mA - 0.1 mA DC
9.5 V DC
Included in delivery
Module completly assembled and ready for installation in the
¿re alarm panels with connecting plugs.
125 mA DC
thermally self-resetting
2.5 mm2
Operating temperature
-20 °C to +70 °C (-4 °F to +158 °F)
Storing temperature
Relative humidity
(IEC721-3-3)
IP rating (EN60529)
-20 °C to +70 °C (-4 °F to +158 °F)
max. 95 %
no condensation
IP 20
Housing
Detectors suitable for connection:
see detectors with corresponding voltage range and for monitoring of exhaust- and air conditioning ducts.
BMX1001 Bypassbox
719754
Applicable safety barrier with suitable
detectors:
Safety barrier Ex Standard 9 V
904991
Connection / mounting
On TH 35 mounting rail in accordance with IEC/EN 60715.
Module can also be inserted in separate housings outside the
¿re alarm control panel.
Connection diagram
Polyamid PA6.6, green
Mounting position
Mounting
Weight
Dimensions
vertical
35 DIN 46277 mounting rail, cap
pro¿le
150 g (0.3 lbs)
23 x 100 x 100 mm (WxHxD)
0.9 x 3.9 x 3.9 inch (WxHxD)
Approvals / marking
P31.301.421 - 13en / 02.13
See panels
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 1 - 37
Product Sheet | Detecon
Fire alarm and extinguishing control panels
FMZ 5000 modules/cards
FMZ 5000 reverse voltage module
Order no.: 915945
Functional module for connection of alarm devices by using a
polarity switchover.
The module FMZ 5000 Reverse Voltage realizes a polarity
switchover of one or two primary control groups within the ¿re
detection and extinguishing control panel. When in idle state,
the alarm devices are connected with „reversed“ polarity. The
polarity is changed back in activated condition and the alarm
devices activated.
Included in delivery
Product features
•
Polarity switchover for controlling of alarm devices.
•
2 switchover circuits, electrically separated from one
another.
•
For a polarity switchover of one or two primary control
groups.
•
Easy installation in alarm systems using mounting rail
(DIN rail).
1 Module (ready-to-install) with all connecting terminals
2 End-of-line resistors (EOL) 1k / 3/4W
1 Product information
Note
All alarm devices in the Minimax product portfolio can be
operated with reverse voltage.
Connection diagram
Technical specifications
Operating voltage
19 V - 29 V DC
Quiescent current
0 mA
Max. contact rating
Number of switchover
circuits
Max. terminal cross-section
Operating temperature
Storage temperature
Relative humidity
(IEC721-3-3)
IP rating (EN60529)
Enclosure
Mounting
Weight
P31.301.421 - 27en / 02.14
Dimensions
**
2
2,5 mm2 (0.004 square inch)
-5 °C to +40 °C (+23 °F to +104 °F)
-10 °C to +50 °C (+14 °F to +122 °F)
max. 95 %
no condensation
IP 20
Polyamide PA6.6, green
Installation position
*
max. 3 A at 30 V DC
Vertical
Mounting rail 35 DIN 46277,
top hat pro¿le
70 g
19x81x70 mm (WxHxD)
1.4 x 3.9 x 4.5 inch (WxHxD)
* All Mx alarm devices have a diode included.
**End-of-line resistor (EOL) included in delivery (2 pieces).
Optionally, the control group 3 and/or 4 or also control groups
of different control group modules can be used. Both
switchover circuits of the module FMZ 5000 reverse voltage
are electrically separated from one another.
Approvals / marking
See panels
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 1 - 38
Product Sheet | Detecon
Fire alarm and extinguishing control panels
FMZ 5000 modules/cards
Loop AP protocol interface
Order no.: 901322
Control device for operating ¿re detectors in the Ex „intrinsically safe“ type of protection in hazard areas together with
the safety barrier.
Application
Product features
•
Connection-ready device for mounting on a
TS35 mounting rail.
•
No adjustment or maintenance work
required.
•
Random branching from Ringbus Loop AP.
The protocol interface is switched to the detector loop, forming a branch.
After the protocol interface the safety barrier, order no.
901324, must be switched to the stub.
Included in delivery
1 Loop AP protocol interface
Technical specifications
Operating voltage
Output voltage
16.5 - 19 V DC
Current consumption
1 mA DC
Maximum current output
30 mA DC
Current pulse input
17 - 23 mA DC
Current pulse output
Operating temperature
Relative humidity
(IEC721-3-3)
IP rating (EN60529)
Mounting
Site of installation
Connection diagram
19 - 28 V DC
8 - 12 mA DC
-20 °F to +60 °C (-4 °F to +140 °F)
max. 95 %
no condensation
IP 20
Mounting rail 35 DIN 46277,
top hat pro¿le
Secure area / non Ex area
Weight
Dimensions
100 g (0.2 lbs)
20 x 92.5 x 111 mm (WxHxD)
0.8 x 3.6 x 4.4 inch (WxHxD)
TP31.301.421 - 22en / 02.13
Approvals / marking
Ex conformity in acc. with 94/9/EC
Ex type approval certi¿cate:
x II (1)GD [Ex ia] IIC
BAS 00 ATEX 7087
IECEx BAS 08.0079
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 1 - 39
Product Sheet | Detecon
Fire alarm and extinguishing control panels
FMZ 5000 modules/cards
Safety barrier IS addressable 24 V
Order no.: 901324
Control device for the operation of "intrinsically safe Ex ib"
detectors in potentially hazard areas.
The safety barrier limits the power supplied to an intrinsically
safe electric circuit in such a way that neither sparks nor
thermal effects can cause an ignition.
The intrinsically safe electric circuit of the safety barrier is
suitable for zones 1 and 2 as well as zones 21 and 22.
VDE0105 Part 9 applies to the operation of electrical systems
in potentially hazard areas.
Application
Product features
•
Device ready for connection for mounting on a mounting
rail TS35.
•
No adjustment or maintenance work required.
The safety barrier is connected to a stub line of the detector
loop.
The Apollo protocol converter, order no.: 901322, needs to be
connected in front of the safety barrier.
•
Galvanic isolation of the input from the safety zone.
Included in delivery
1 safety barrier IS addressable 24 V
Note
Technical specifications
Rated voltage
Output voltage
Maximum current
Maximum external
connection values IIC
Maximum external
connection values IIB
Ambient temperature
Relative humidity
(IEC721-3-3)
IP rating (EN60529)
Mounting
Mounting location
Weight
Dimensions
UN = max. 26 V
UA = UN - (0,38 x I [mA]) - 0.5
93 mA DC
0.13 ȝF; 4.2 mH
0.39 ȝF; 12.6 mH
-20 °C to +60 °C (-4 °F to +140 °F)
max. 90 %
no condensation
IP 20
Mounting rail 35 DIN 46277,
top hat pro¿le
Safe area / not potentially explosive
area
100 g (0.2 lbs)
20 x 107 x 115 mm (WxHxD)
0.8 x 4.2 x 4.5 inch (WxHxD)
For the interconnection of intrinsically safe detectors to the
intrinsically safe electric circuit of the safety barrier, the corresponding maximum values of the detectors need to be
observed.
The maximum permissible values for capacitive and inductive
loads must be complied with.
The safety barrier must be connected to the potential equalisation within the potential hazard area. Potential equalisation
in accordance with JEC 60079-14/EN 60079-14 must exist
for all intrinsically safe electric circuits.
When setting up intrinsically safe electric circuits in potentially
hazard areas, the corresponding applicable national and
international setup regulations need to be observed.
Connection diagram
P31.301.421 - 23en / 01.14
Approvals / marking
Ex conformity in acc. with 94/9/EC
x II (1)GD EEx ia IIC
Ex conformity Russia in acc. with TP TC 012/2011:
[Ex ia Ga] IIC
[Ex ia Da] IIIC
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 1 - 40
Product Sheet | Detecon
Fire alarm and extinguishing control panels
FMZ 5000 modules/cards
Safety barrier IS conventional 9 V
Order no.: 904991
Control gear unit for the operation of "intrinsically safe Ex ib"
detectors in potentially hazard areas.
The safety barrier limits the power supplied to an intrinsically
safe electric circuit in such a way that neither sparks nor
thermal effects can cause an ignition.
The intrinsically safe electric circuit of the safety barrier is
suitable for zones 1 and 2 as well as zones 21 and 22.
VDE0105 Part 9 applies to the operation of electrical systems
in potentially hazard areas.
Product features
Application
•
Device ready for connection for mounting on a mounting
rail TS35.
The safety barrier is connected to a conventional detector
line.
•
No adjustment or maintenance work required.
Rated voltage
UN = 9 V DC; max. 10.6 V DC
Output voltage
UA = UOn - 1.4 V at 75 mA DC
Mounting
Mounting location
Weight
Dimensions
1 safety barrier IS conventional 9 V
Note
Technical specifications
Rated current
Maximum external
connection values IIC
Maximum external
connection values IIB
Ambient temperature
Relative humidity
(IEC721-3-3)
IP rating (EN60529)
Included in delivery
IN = 85 mA DC
0.37 ȝF; 0.75 mH
0.95 ȝF; 7 mH
-20 °C to +60 °C (-4 °F to +140 °F)
max. 90 %
no condensation
IP 20
Mounting rail 35 DIN 46277,
top hat pro¿le
Safe area /
not potentially explosive area
175 g (0.4 lbs)
22.5 x 79 x 85.5 mm (WxHxD)
0.9 x 3.1 x 3.4 inch (WxHxD)
For the interconnection of intrinsically safe detectors to the
intrinsically safe electric circuit of the safety barrier, the corresponding parameters values of the detectors need to be
observed.
The maximum permissible values for capacitive and inductive
loads must be observed.
The safety barrier must be connected to the potential equalisation within the potentially hazard area. Potential equalisation in accordance with JEC 60079-14/EN 60079-14 must
exist for all intrinsically safe electric circuits.
When setting up intrinsically safe electric circuits in potentially
hazard areas, the corresponding applicable national and
international setup regulations need to be observed.
Connection diagram
Approvals / marking
Ex conformity in acc. with 94/9/EC
x II 2G Ex ib IIC
x II 2D Ex ibD
x I M2 Ex ib I
P31.301.421 - 24en / 01.14
Ex conformity Russland in acc. with TP TC 012/2011:
[Exib] IIC
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 1 - 41
Product Sheet | Detecon
Fire alarm and extinguishing control panels
FMZ 5000 modules/cards
FMZ 5000 central card
Order no: 910708
The central control card constitutes the main unit of the
FMZ 5000 ¿re alarm- and extinguishing control panel. Includes all the components for communicating with the modules
used in the panel, the front panel for displaying messages
and for operating the panel. In addition the ¿rmware and
project-related settings for the panel are stored. A licence
for the operating system is automatically delivered with each
central card.
Application
Card exclusively as replacement part to be exchanged for
a defective card in an existing FMZ 5000 ¿re alarm control
panel mod 4, mod 12, mod XL 21 HE, mod XL 31 HE or
mod XL 40 HE.
Technical specifications
Operating voltage
24 V DC ± 15 %
Quiescent current
approx. 110 mA DC
Operating temperature
Weight
Dimensions
Approvals / marking
See panels
- 5 °C to + 40 °C (+23 °F to +104 °F)
248 g (0.6 lbs)
245 x 165 mm (BxL)
9.7 x 6.5 inch (BxL)
Included in delivery
Card complete for exchange in an existing FMZ 5000 ¿re
alarm control panel.
Not included in delivery
CompactFlash memory card
Connection cable, plug, mounting accessories
905881
Spare parts
Encoding connector AKSN/G (Jumper)
805412
Note
P31.301.421 - 25en / 02.13
When swapping out the card take all ESD precautions. In
each case before exchanging the card, turn off the panel
and disconnect from mains voltage. Observe correct seating
of the foil connections to the front foil and the ribbon cable
plugs.
Insert the CompactFlash memory card from the defective
central card. You may have to insert a new memory card
provided by Minimax. In this case the con¿guration data must
be loaded directly on to the new card or via download using
the MxSysCon con¿guration program.
The central card contains the latest respective version of the
¿rmware. In each case the compatibility of the ¿rmware with
the version of all in the panel installed modules and of the
con¿guration data on the memory card must be checked.
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 1 - 42
Product Sheet | Detecon
Fire alarm and extinguishing control panels
FMZ 5000 modules/cards
FMZ 5000 central card redundant
Order no.: 910707
Card for achieving the processor redundancy in compliance
with EN54-2 and VdS2095 if during application of the control
panel at least one of the following cases applies:
- More than 512 detectors are connected
- the monitored area is larger than 12000 m2
(1435 square yard)
- More than one extinguishing zone is triggered.
The card is inserted into the plug strips X1 and X2 of the
central card.
Spare parts
Coding plug AKSN/G (jumper)
Approvals / marking
Technical specifications
Weight
70 g (0.2 lbs)
135 x 100 x 20 mm (WxLxH)
5.3 x 3.9 x 0.8 inch (WxLxH)
Dimensions
805412
CompactFlash 256 MB memory card
See panels
Order no.: 905881
CompactFlash memory card with ATA communications interface and 256 MByte capacity for use in the FMZ 5000 control
card.
The card has an extended temperature range of
-40 °C to 85 °C (-40 °F to 185 °F).
The card is used for saving current and past states of the ¿re
alarm- and extinguishing control panel.
It is also used to store the control panels con¿guration data.
Apart from the control unit the card can be read or written to
with any memory card reading device.
Technical specifications
Memory capacity
Operating temperature
Relative humidity
(IEC721-3-3)
Mounting
P31.301.421 - 25en / 02.13
Weight
Dimensions
Included in delivery
min. 256 MB
- 40 °C to + 85 °C (-40 °F to +185 °F)
max. 95 %
No condensation
in socket on the ¿re alarm central
card
9 g (0.02 lbs)
42 x 36 x 4 mm (BxLxH)
1.7 x 1.4 x 0.2 inch (BxLxH)
256 MB CompactFlash memory card without data
Not included in delivery
Read/write device for external reading or writing
Note
The CompactFlash memory card should be formatted before
¿rst use.
Only those CompactFlash memory cards with the extended
temperature range are authorised for use in the FMZ 5000.
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 1 - 43
Product Sheet | Detecon
Fire alarm and extinguishing control panels
FMZ 5000 modules/cards
FMZ 5000 zone operating panel card
Order no.: 901518
Card for use in all design varriants of the FMZ 5000 ¿re alarm
panel system.
Includes 16 groups with one red and one yellow LED each
and 4 membrane keys with freely con¿gurable function.
In addition there are 4 connections for uses such as keyoperated switches on the front plate.
Labelling is by means of sliding labels behind transparent
windows - one window per zone operating panel, LED group
and membrane key.
Product features
Application
•
Each LED can be con¿gured for indication by steady
light, Àashing and rapid Àashing.
For displaying individual indications of signals, faults, activations, shutdowns etc.
Up to 27 cards can be used in one ¿re alarm panel.
•
Each membrane key can be used as a switching actuator
or a momentary-contact actuator.
Included in delivery
•
All settings are carried out using the MxSysCon con¿guration program.
•
No adjustment work is required.
Technical specifications
Operating voltage
Quiescent current
Ambient temperature
Relative humidity
(IEC721-3-3)
IP rating (EN60529)
Mounting
19 V - 29 V DC
10 mA DC
-5 °C to +40 °C (+23 °F to +104 °F)
max. 95 %
no condensation
IP 20
On the rear side of the front plate
Weight
Dimensions
Card, separate or as part of a complete retro¿t kit including
mounting accessories for installation behind the front plate.
Complete retro¿t kit
includes:
Zone operating panel card
Mounting accessories
Artwork master 50 LCD
Artwork master 50 BBF
90 3340
901518
904981
903281
903282
Not included in delivery
Front plate FMZ 5000 BBF
901733
Note
Connected switches / buttons must not be ¿tted outside the
central ¿re alarm system.
40 g (0.1 lbs)
70 x 113 mm (WxH)
2.8 x 4.5 inch (WxH)
Approvals / marking
P31.301.421 - 26en / 02.13
See panels
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 1 - 44
Product Sheet | Detecon
Fire alarm and extinguishing control panels
FMZ 5000 enclosure/front plates
Front plate FMZ 5000 BBF
Order no.: 901733
Front plate for housing up to ¿ve zone operating panels.
Has 16 red/yellow LED pairs and four membrane keys for
each panel.
Labelling ¿elds as headers for each zone operating panel
and one labelling ¿eld for each LED pair, designed to accept
sliding labels.
Not included in delivery
Card FMZ 5000 zone operating panel
Add-on kit FMZ 5000 front panel BBF
Retro¿t kit FMZ 5000 BBF
pan-head screw with washer M6 x 16
in packs of 100
Technical specifications
Colour
RAL 7035
Material
Aluminium
Weight
750 g (1.7 lbs)
19” x 4U (WxH)
P31.301.450 - 1en / 02.13
Dimensions
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 1 - 45
901518
904119
903340
607284
Product Sheet | Detecon
Fire alarm and extinguishing control panels
FMZ 5000 enclosure/front plates
Dummy plate 1U
Order no.: 905492
Technical specifications
Dummy plates for covering unused areas on the front of
panel enclosures FMZ 5000 mod 12 and mod XL.
Colour
RAL 7035
Material
Aluminium
Weight
190 g (0.4 lbs)
Dimensions
Pan-head screw with washer M6 x 16
in packs of 100
607284
Dummy plate 2U
Order no.: 902411
Technical specifications
Dummy plates for covering unused areas on the front of
panel enclosures FMZ 5000 mod 12 and mod XL.
Colour
RAL 7035
Material
Aluminium
Weight
360 g (0.8 lbs)
Dimensions
19" x 2U (WxH)
Not included in delivery
Pan-head screw with washer M6 x 16
in packs of 100
607284
Dummy plate 3U
Order no.: 902412
Technical specifications
Dummy plates for covering unused areas on the front of
panel enclosures FMZ 5000 mod 12 and mod XL.
Colour
RAL 7035
Material
Aluminium
Weight
540 g (1.2 lbs)
Dimensions
P31.301.450 - 2en / 02.13
19" x 1U (WxH)
Not included in delivery
19" x 3U (WxH)
Not included in delivery
Pan-head screw with washer M6 x 16
in packs of 100
607284
Dummy plate 4U
Order no.: 902413
Technical specifications
Dummy plates for covering unused areas on the front of
panel enclosures FMZ 5000 mod 12 and mod XL.
Colour
RAL 7035
Material
Aluminium
Weight
765 g (1.7 lbs)
Dimensions
19" x 4U (WxH)
Not included in delivery
Pan-head screw with washer M6 x 16
in packs of 100
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 1 - 46
607284
Product Sheet | Detecon
Fire alarm and extinguishing control panels
FMZ 5000 enclosure/front plates
Dummy plate 5U
Order no.: 902414
Technical specifications
Dummy plates for covering unused areas on the front of
panel enclosures FMZ 5000 mod 12 and mod XL.
Colour
RAL 7035
Material
Aluminium
Weight
895 g (2 lbs)
19" x 5U (WxH)
Pan-head screw with washer M6 x 16
in packs of 100
P31.301.450 - 2en / 02.13
Dimensions
Not included in delivery
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 1 - 47
607284
Product Sheet | Detecon
Fire alarm and extinguishing control panels
FMZ 5000 power supply units
Power supply PSU 2403
Order no.: 908878
The PSU 2403 is an independent power supply for uninterrupted operation (UPS) with the following special features:
- Temperature compensation (temperature sensor)
- Shutoff in case of low battery.
For use as decentralized power supply of devices such as
smoke aspirating systems. Consumers can be connected via
2 separately fused outputs. 3 dry contacts are available for
the messages operation, power failure, battery failure or fault
output 1 or output 2.
Temperature-controlled battery charging for 2 batteries 12 V
max. 26 Ah. Connected batteries are continuously monitored.
The output voltage is short-circuit proof.
Technical specifications
Mains voltage
Output voltage
Output current
Battery capacity
195 V - 264 V AC
24 V DC
max. 3 A DC
2 x 12 V / 7 Ah to 26 Ah
Ambient temperature
-5 °C to +40 °C (23 °F to +104 °F)
Storage temperature
-25 °C to +85 °C (-13 °F to +185 °F)
Relative humidity
Weight
6 kg (13.2 lbs)
289 x 350 x 189 mm (WxHxD)
11.4 x 13.8 x 7.4 inch (WxHxD)
Complete power supply, ready for installation and operation.
Not included in delivery
spare fuses 3.15 A
Batteries 12 V
908576
Approvals / marking
applied
0333-CPD-075373
P31.301.511 - 1en / 01.14
Dimensions
20 to 95 %,
Included in delivery
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 1 - 48
Product Sheet | Detecon
Fire alarm and extinguishing control panels
FMZ 5000 power supply units
Power supply unit NT5100 3A
Order no.: 908452
The power supply unit is used for the uninterrupted power
supply of the following:
- Fire alarm panels FMZ 5000 mod 4 / 12
- Other external devices
with a rated operating voltage of 24V DC.
Temperature-controlled battery charging for 2 batteries 12 V
max. 26 Ah. Connected batteries are continuously monitored.
The output voltage is short-circuit proof.
Included in delivery
Power supply unit completely assembled and ready for
installation in the device on mounting rail.
Technical specifications
Mains voltage
Output current Imax b
Output voltage
Battery capacity
Ambient temperature
Speci¿cation according to
Weight
Not included in delivery
Spare fuse 3.15 A / 250 V
908576
3 A DC
2 x 12 V / 21 V - 29 V DC
Approvals / marking
7,2 Ah to 26 Ah
- 5°C to + 50 °C (-4 °F to +122 °F)
G 209209
0333-CPD-075232
EN54-4 A2:2006
0.8 kg (1.8 lbs)
185 x 105 x 65 mm (WxHxD)
7.3 x 4.1 x 2.6 inch (WxHxD)
P31.301.511 - 2en / 01.14
Dimensions
115 V / 230 V ±15% AC
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 1 - 49
Product Sheet | Detecon
Fire alarm and extinguishing control panels
FMZ 5000 power supply units
Power supply unit NT5000 5A
Order no.: 901037
The power supply unit is used for the uninterrupted power
supply of the following:
- Fire alarm panels FMZ 5000 mod 12 / XL
- Other external devices
with a rated operating voltage of 24V DC.
Temperature-controlled battery charging for 2 batteries 12 V
max. 26 Ah. Charging characteristics are adjustable for
different battery types.
Connected batteries are continuously monitored.
The output voltage is short-circuit proof.
Group fault indication as GND switching relay output.
Included in delivery
Technical specifications
Mains voltage
115 V / 230 V -15%, +10% AC
5 A DC
Output current Imax b
Output voltage
21 V - 29 V DC
Battery capacity
Ambient temperature
Power supply unit completely assembled and ready for
installation in the device on mounting rail.
Not included in delivery
Spare fuse 15 A
891423
2 x 12 V /12 Ah to 26 Ah
-5 °C to +50 °C (-4 °F to +122 °F)
Speci¿cation according to
EN54-4 A2:2006
Weight
1.3 kg (2.9 lbs)
190 x 129 x 103 mm (WxHxD)
7.5 x 5.1 x 4.1 inch (WxHxD)
Dimensions
Power supply unit NT5000 15A
Approvals / marking
0786-CPD-20360
G 204140
Order no.: 901038
The power supply unit is used for the uninterrupted power supply
of the following:
- Fire alarm panels FMZ 5000 XL
- Other external devices such as aspirating smoke detectors
with a rated operating voltage of 24V DC.
Temperature-controlled battery charging for 2 batteries 12 V
max. 115 Ah. Charging characteristics are adjustable for
different battery types. Connected batteries are continuously
monitored.
The output voltage is short-circuit proof.
Group fault indication as GND switching relay output.
Included in delivery
Technical specifications
Mains voltage
Output current Imax b
P31.301.511 - 3en / 02.13
Output voltage
Battery capacity
Ambient temperature
Speci¿cation according to
Weight
Dimensions
115 V / 230 V -15%, +10% AC
15 A DC
21 V - 29 V DC
Power supply unit completely assembled and ready for
installation in the device on mounting rail.
Not included in delivery
Spare fuse 20 A
904021
2 x 12 v /24 Ah to 115 Ah
-5 °C to +50 °C (-4 °F to +122 °F)
EN54-4 A2:2006
3.2 kg (7.1 lbs)
250 x 150 x 103 mm (WxHxD)
9.8 x 5.9 x 4.1 inch (WxHxD)
Approvals / marking
G 204139
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
0786-CPD-20282
Chapter 1 - 50
Product Sheet | Detecon
Fire alarm and extinguishing control panels
FMZ 5000 batteries
Battery 2.2 Ah
Order no.: 236023
Technical specifications
Approvals / marking
Connection
Blade terminal 4.8 mm (0.19 inch)
Weight
1.0 kg (2.2 lbs)
178 x 34 x 65 mm (WxHxD)
7 x 1.3 x 2.6 inch (WxHxD)
Dimensions
G 107033
Included in delivery
1 battery 12V / 2.2 Ah
Battery 7.2 Ah
Order no.: 902941
Technical specifications
Approvals / marking
Connection
Blade terminal 4.8 mm (0.19 inch)
Weight
2.6 kg (5.7 lbs)
151 x 102 x 65 mm (WxHxD)
5.9 x 4 x 2.6 inch (WxHxD)
Dimensions
G 107034
Included in delivery
1 battery 12V / 7.2 Ah
Battery 12 Ah
Order no.: 761677
Technical specifications
Approvals / marking
Connection
Blade terminal 6.3 mm (0.25 inch)
Weight
4.6 kg (10.1 lbs)
151 x 98 x 99 mm (WxHxD)
5.9 x 3.9 x 3.9 inch (WxHxD)
Dimensions
G 107036
Included in delivery
P31.301.521en / 02.13
1 battery 12V / 12 Ah
Battery 18 Ah
Order no.: 756859
Technical specifications
Approvals / marking
Connection
Weight
Dimensions
(5 mm (0.2 inch) hole) blade terminal
6.5 mm (0.26 inch)
6.4 kg (14.1 lbs)
181 x 167 x 76 mm (WxHxD)
7.1 x 6.6 x 3 inch (WxHxD)
G 107037
Included in delivery
1 battery 12V / 18 Ah
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 1 - 51
Product Sheet | Detecon
Fire alarm and extinguishing control panels
FMZ 5000 batteries
Battery 26 Ah
Order no.: 132721
Technical specifications
Connection
Weight
Dimensions
(5 mm (0.2 inch) hole) blade terminal
6.3 mm (0.25 inch)
9.6 kg (21.2 lbs)
166 x 125 x 175 mm (WxHxD)
6.5 x 4.9 x 6.9 inch (WxHxD)
Approvals / marking
G 107038
Included in delivery
1 battery 12V / 26 Ah
Battery 45 Ah
Order no.: 832386
Technical specifications
Connection
Weight
Dimensions
(5 mm (0.2 inch) hole) blade terminal
6.3 mm (0.25 inch)
14.2 kg (31.3 lbs)
197 x 172 x 166 mm (WxHxD)
7.8 x 6.8 x 6.5 inch (WxHxD)
Approvals / marking
G 107039
Included in delivery
1 battery 12V / 45 Ah
Battery 65 Ah
Order no.: 794921
Technical specifications
Connection
Weight
Dimensions
(6 mm (0.24 inch) hole) blade terminal
6.3 mm (0.25 inch)
23.6 kg (52 lbs)
350 x 174 x 166 mm (WxHxD)
13.8 x 6.9 x 6.5 inch (WxHxD)
Approvals / marking
G 107040
Included in delivery
1 battery 12V / 65 Ah
Order no.: 801758
Battery 85 Ah
Technical specifications
Connection
Weight
Dimensions
(Conical pin) blade terminal 6.3 mm
(0.25 inch)
31.0 kg (68.3 lbs)
330 x 171 x 232 mm (WxHxD)
13 x 6.7 x 9.1 inch (WxHxD)
Approvals / marking
G 190046
Included in delivery
P31.301.521en / 02.13
1 battery 12V / 85 Ah
Battery 115 Ah
Order no.: 800775
Technical specifications
Approvals / marking
Connection
Weight
Dimensions
(Conical pin) blade terminal 6.3 mm
(0.25 inch)
40.0 kg (88.2 lbs)
267 x 284 x 230 mm (WxHxD)
10.5 x 11.2 x 9.61 inch (WxHxD)
Included in delivery
1 battery 12V / 115 Ah
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 1 - 52
Product Sheet | Detecon
Fire alarm and extinguishing control panels
FMZ 5000 Fire alarm panel accessories
Ribbon cable 10 wire
Order no.: 853805
Technical specifications
Weight
18 g/m (0.04 lbs/m)
Quantity unit for orders = metres.
Ribbon cable, round, shielded 20 wire
Order no.: 800315
Technical specifications
Weight
118 g/m (0.3 lbs/m)
Quantity unit for orders = metres.
Ribbon cable shielded 20 wire
Order no.: 784157
Technical specifications
Weight
43 g/m (0.09 lbs/m)
Quantity unit for orders = metres.
Female connector 2 x 5 pol.
Order no.: 796759
Technical specifications
Weight
Female connector 2 x 10 pol.
1 g (0.002 lbs)
Order no.: 784170
Technical specifications
Weight
Cable set FMZ 5000 mod S Relay card
3 g (0.007 lbs)
Order no.: 913673
Technical specifications
Weight
6 g (0.01 lbs)
P31.301.590en / 01.14
Included in delivery
1 Cable set complete with socket
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 1 - 53
Product Sheet | Detecon
Fire alarm and extinguishing control panels
FMZ 5000 Fire alarm panel accessories
Key set BMA control panel
NEW Order no.: 917687
Key set for all FMZ 5000 ¿re detection and alarm control
panels and connected peripheral equipment.
Product features
Allows access to Minimax ¿re detection and alarm control
panels of the FMZ 5000 series.
•
Allows access to manual call point for indoor applications.
•
Allows access to „Zonecheck“.
Included in delivery
Technical specifications
80 g (0.17 lbs)
Key for:
1 DMX3000
1 FMZ 5000 mod XL / mod 12 / mod S
1 FMZ 5000 mod XL, pivoting frames
1 FMZ 5000 mod 12, internal door
1 FMZ 5000 mod S, front panel
1 Zonecheck
P31.301.590-03en / 03.14
Weight
•
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 1 - 54
Product Sheet | Detecon
Fire alarm and extinguishing control panels
FMZ 5000 Fire alarm panel accessories
Fire protection housing F 30
FMZ 5000 mod 12
NEW Order no.: 917789
The ¿re protection housing is intended for use in areas
where according to MLAR the FMZ 5000 (electric distributor)
must be separated from passageways, staircases as well as
outdoor exits and the use of distributors for electrical circuit
systems with functional integrity for 30 minutes (cable routing
E 30) is required.
Product features
Technical specifications
Speci¿cations
Source and disposition
Enclosure
Dimensions
IP rating (EN60529)
functional integrity 30 minutes
- according to E 30
¿re resistance 30 minutes
- according to F 30
¿re load insulation 30 minutes
- according to I 30
based on ABZ-Nr. Z-86.1-5
based on ABZ-Nr. Z-86.1-10
composite material
outside: 978 x 828 x 395 mm (WxHxD)
38.50 x 32.59 x 15.55 inch (WxHxD)
inside: 800 x 650 x 300 mm (WxHxD)
31.96 x 25.59 x 11.81 inch (WxHxD)
IP 54, protection class II
Colour
similar to RAL 7035
Weight
approx. 105 kg ( 231.48 lbs)
Mounting
Wall-mounted installation
•
•
Tailored ¿re protection housing for FMZ 5000 mod 12.
Certi¿ed protection housing in accordance to DIN 4102-2.
•
Panel speci¿c cable glance grid through incombustible
basic ¿re protection plate according to EN 13501-A2.
•
4 integrated mounting points and speci¿c
FMZ 5000 mod 12 mounting plate.
Included in delivery
Fire protection housing F 30
Mounting hardware: screws and dowels
Not included in delivery
Lock cylinder ¿re protection housing F 30
918146
Note
The ¿re protection housing F 30 has a left-hinged door stop
with hidden steal hinges for free access to the ¿re alarm and
control panel during commissioning and maintenance.
The ¿re protection housing can be opened using a swivelling
lever in which a DIN half cylinder can be retro¿tted.
If access level 1 according to DIN 54-2 (without speci¿c
procedures) is required, then the lock cylinder ¿re protection
housing F 30 (Order no. 918146) must be used instead of the
standard keys provided.
P31.301.590-02en / 03.14
Fire protection housing F 30
FMZ 5000 mod 4
NEW Order no.: 917788
Technical specifications
Dimensions
Weight
Otherwise like Order no.: 917789
outside: 728 x 728 x 345 mm (WxHxD)
28.66 x 28.66 x 13.58 inch (WxHxD)
inside: 550 x 550 x 250 mm (WxHxD)
21.65 x 21.65 x 9.84 inch (WxHxD)
approx. 71 kg ( 156.52 lbs)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 1 - 55
Product Sheet | Detecon
Fire alarm and extinguishing control panels
FMZ 4100 cards
Relay expansion card 8
Order no.: 802587
Relay expansion card for use in all variants of the FMZ 5000
control system.
Contains 8 relays with freely con¿gurable function. Two changeover contacts per relay are connected to the connecting
terminal.
A 10-pin ribbon cable must be used to connect the card.
The relays are actuated by a 0 V signal via the ribbon cable
or the wires to the soldering terminals.
Product features
Application
•
Each relay can be activated separately.
•
Activation of a relay is displayed by its own LED.
•
Wires can also be connected directly to the soldering
terminals for activation of the relays.
•
All settings are implemented with the con¿guration
programme of the control unit in which the card
is inserted.
•
No adjustments are necessary.
For further noti¿cation of any state messages or triggering of
unmonitored loads.
Card can be used per relay module in the FMZ 5000. In the
FMZ 5000 mod S card can be connected to the mainboard.
Included in delivery
Card with mounting brackets for mounting on a mounting
rail.
Not included in delivery
Relay SDS 24 V DC
Ribbon cable 10-lead (bulk stock)
Female connector 2 x 5 pin.
Cable set FMZ 5000 mod S Relay card
Technical specifikations
Mains voltage
Quiescent current
No. of relays
Current per relay
Contact load
Contact rating
Contacts per relay
Terminal cross-section
Ambient temperature
Relative humidity
(IEC721-3-3)
Enclosure
Weight
P31.301.120en / 01.14
Dimensions
796085
853805
796759
913673
21 V - 29 V DC
0 mA DC
8
8.5 mA (relay activated)
Note
The relay contacts are not suitable for switching 230 V AC
mains voltage.
4 A / 30 V DC
max. 90 W / 1000 VA
2 changeover contacts, potential-free
max. 4 mm2 (0.006 square inch)
-5 °C to +40 °C (+23 °F to +104 °F)
max. 95 %
no condensation
Mounting rail 35 DIN 46277,
top hat pro¿le
166 g (0.36 lbs)
140 x 68 x 48 mm (WxLxD)
5.5 x 2.7 x 1.9 inch (WxLxD
Approvals / marking
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 1 - 56
Product Sheet | Detecon
Fire alarm and extinguishing control panels
FMZ 4100 cards
Relay expansion card 8TQ
Order No.: 800843
Relay expansion card for use in all variants of the FMZ 5000
control panel.
Contains 8 relays with freely con¿gurable function. One
changeover contact per relay is connected to the connecting
terminal.
The relay is actuated via a 0 V signal. A 10-ribbon pin cable
must be used to connect the card.
Product features
Application
•
Each relay can be activated separately.
•
All settings are implemented with the con¿guration
programme of the control panel in which the card
is inserted.
•
No adjustments are necessary.
For further noti¿cation of any state messages or triggering of
unmonitored loads.
Card can be used per relay module in the FMZ 5000. In the
FMZ 5000 mod S card can be connected to the mainboard.
Included in delivery
Card with mounting brackets for mounting on a mounting
rail.
Technical specifikations
Mains voltage
Quiescent current
No. of relays
Current per relay
Contact load
Contact rating
Contacts per relay
Terminal cross-section
Ambient temperature
Relative humidity
(IEC721-3-3)
Enclosure
Weight
Dimensions
21 V - 29 V DC
0 mA DC
8
6 mA (relay activated)
1 A / 30 V DC
max. 30 W / 62,5 VA
1 changeover contacts, potential-free
Not included in delivery
Ribbon cable 10-lead (bulk stock)
Female connector 2 x 5 pol.
Cable set FMZ 5000 mod S Relaycard
853805
796759
913673
Note
The relay contacts are not suitable for switching 230 V AC
mains voltage.
max. 4 mm2 (0.006 square inch)
-5 °C to +40 °C (+23 °F to +104 °F)
max. 95 %
no condensation
Mounting rail 35 DIN 46277,
top hat pro¿le
96 g (0.21 lbs)
70 x 68 x 48 mm (WxLxD)
2.8 x 2.7 x 1.9 inch (WxLxD)
P31.301.120en / 01.14
Approvals / marking
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 1 - 57
Product Sheet | Detecon
Fire brigade and system accessories
Fire brigade control panels
Fire brigade control panel FBF 2001
Order no.: 908147
Fire brigade control panel for Minimax FMZ 5000 fire alarm
panels in accordance with DIN 14661.
The front door can be locked with a case lock with profile half
cylinder in accordance with DIN 18252.
Connection – mounting
The control panel is connected directly to the remote
transmission unit module using a 20-pin ribbon cable. For
this the ADP-FBF-MX connector card needs to be inserted in
the FBF. Alternatively, for connection using cable wires, the
FLK20 adapter (from Phoenix Contact) can be used in the
fire alarm panel.
Included in delivery
Technical specifications
Operating voltage
10 V - 30 V DC
Quiescent current consumption (24 V)
approx. 10 mA
Alarm current consumption (24 V)
Operating temperature
IP rating
approx. 75 mA
0 °C to +50 °C
(+32 °F to +122 °F)
IP 30
Enclosure colour
Weight
Dimensions
RAL 7032
3.4 kg (7.5 lbs)
255 x 185 x 58 mm
10 x 7.3 x 2.3 inch
(WxHxD)
Fire brigade control panel FBF2003
serial mod S
Fire brigade control panel completely assembled and ready
for connection to the fire alarm panel, including ADP-FBF-MX
connector card.
Not included in delivery
Mounting hardware: screws and dowels
Ribbon connecting cable, round
Remote transmission unit module
Profile half cylinder
800315
901969
Approvals / marking
G 299034
Order no.: 910530
Fire brigade control panel for Minimax FMZ 5000 mod S fire
alarm panels in accordance with DIN 14661.
The front door can be locked with a case lock with profile half
cylinder in accordance with DIN 18252
Connection - mounting
Connection takes place via the RS422 interface of the FMZ
5000 mod S card's fire alarm peripheral. This card is not
included in the basic version of the unit.
Included in delivery
Fire alarm control panel, completely ready for assembly to be
connected to the fire alarm control unit.
Technical specifications
Operating voltage
10 V - 42 V DC
Quiescent current consumption (24 V)
approx. 15 mA
Alarm current consumption (24 V)
P31.302.110en / 02.13
Operating temperature
IP rating
Enclosure colour
Weight
Dimensions
approx. 30 mA
0 °C to +50 °C
(+32 °F to +122 °F)
IP 30
RAL 7032
3.6 kg (7.9 lbs)
255 x 185 x 58 mm
10 x 7.3 x 2.3 inch
(W x H x D)
Not included in delivery
Mounting hardware: screws and dowels
FMZ 5000 mod S fire accessory
Approvals / marking
G 205053
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 3 - 1
909365
Product Sheet | Detecon
Fire brigade and system accessories
Fire brigade graphic annunciator
Fire brigade graphic annunciator FAT 2002
Order no.: 908148
Fire brigade graphic annunciator for Minimax FMZ 5000 fire
alarm panels in accordance with DIN 14662 for indication
of fire alarm and fault signals as initial information for the
fire brigade. Text display with 4 rows of 20 characters each.
The text sent from the message frame is used, which is why
no configuration is required. Two signals can be displayed at
the same time.
Connection – mounting
Connection is established via the RS232 or RS422 interface
on the SIO1 or SIO3 module. The Mx2 data protocol is used.
Technical specifications
Operating voltage
Quiescent current consumption (24 V)
Alarm current consumption
(24 V)
Operating temperature
Included in delivery
10 V - 30 V DC
approx. 50 mA
max. approx. 170 mA
Fire brigade graphic annunciator completely assembled and
ready for connection to the fire alarm panel.
Interface module with Minimax data protocol. Specify RS232
or RS422 interface when ordering.
0 °C to +50 °C (+32 °F to +122 °F)
IP rating
IP 30
Enclosure colour
Weight
Dimensions
RAL 7032
3.6 kg (7.9 lbs)
255 x 185 x 58 mm (WxHxD)
10 x 7.3 x 2.3 inch (WxHxD)
Not included in delivery
Mounting hardware: screws and dowels
Connecting cable
Profile half cylinder
Approvals / marking
G 203086
Fire brigade graphic annunciator FAT 2002 re
Order no.: 908149
Fire brigade graphic annunciator with redundant data
connection to the fire alarm panel as a source of initial
information for the fire brigade.
Connection – mounting
G 203086
P31.302.120en / 02.13
Connection is established via the RS232 interface on the
SIO1 or SIO3 module, to an ADP-NB adapter card in the fire
alarm panel. The FAT 2002 re is connected to the ADP-NP
via 2 data lines. The Mx2 data protocol is used.
Approvals / marking
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 3 - 2
Product Sheet | Detecon
Fire brigade and system accessories
Fire brigade graphic annunciator
FAT 3000 mod S
Order no.: 910526
Fire brigade graphic annunciator panel for Minimax fire
extinguishing and detection control panels FMZ 5000 mod
S according to DIN 14662 to display fire alarm and fault
messages as initial information for the fire brigade, plain text
display with 4 lines and 20 characters per line. Two messages are simultaneously displayable.
Connection – mounting
The connection occurs via the RS422 interface of the card
FMZ5000 mod S fire brigade peripheral equipment.
This card is not included in the basic configuration of the fire
detection control panel.
Technical specifications
Operating voltage
Quiescent current
consumption (24 V)
Alarm current consumption
(24 V)
Operating temperature
IP rating
Enclosure colour
Weight
Dimensions
10 V - 42 V DC
ca. 50 mA
Included in delivery
Fire brigade graphic annunciator panel complete, ready for
connection to the fire detection control panel.
ca. 80 mA
0 °C bis + 50 °C
(+32 °F to +122 °F)
IP 30
RAL 7032
3.6 kg (7.9 lbs)
255 x 185 x 58 mm (BxHxT)
10 x 7.3 x 2.3 inch (BxHxT)
Not included in delivery
Accessories FMZ 5000 mod S fire brigade
Connection cable
Fastening material, screws and dowels
909365
Approvals / marking
G 205076
FAT 3000 mod S re
Order no.: 910529
Fire brigade graphic annunciator panel with redundant data
connection to the fire detection control panel as initial information for the fire brigade.
Included in delivery
Fire brigade graphic annunciator panel complete, ready for
connection to the fire detection control panel, including ADPN3E-U adapter board.
P31.302.120en / 02.13
Connection – mounting
The connection occurs via the RS422 interface of the card
FMZ 5000 S fire brigade peripheral equipment.
This card is not included in the basic configuration of the fire
detection control panel. Provision of the redundant data interface requires installation of an ADP-N3E.U adapter board in
the fire detection control panel.
Approvals / marking
G 205076
.
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 3 - 3
Product Sheet | Detecon
Fire brigade and system accessories
Graphic panel
LMT-4 LED graphic panel
Order no.: 910169
LED graphic panel in an aluminium housing with hinged grid
plate and transparent front window for a user-defined layout
that can be replaced at any time, e.g.. diagram, plot etc. The
panel allows the placement of LEDs that light up the inserted plan at desired points, plus sensor buttons which trigger
switch functions at any place in the plan by tapping through
the front plate as on a touch panel.
Product features
•
•
Technical specifications
Output voltage
24 V DC
Housing material
Aluminium
Protection class
Weight
Dimensions
For DIN A4 insert with lock
extensive accessories and various interfaces and connection- and distribution boards with parallel or serial
signal inputs.
Included in delivery
1 LMT-4 LED graphic panel without attachment material.
IP 54
1850 g (4.1 lbs)
359 x 272 x 46 mm (WxHxD)
14.13 x 10.7 x 1.8 inch (WxHxD)
LMT-3 LED graphic panel
Not included in delivery
Red LED diodes for LMT panel
Green LED diodes for LMT panel
Yellow LED diodes for LMT panel
8 LED adapter card for LMT panel
Capacitive butten for LMT panel
LED distribution board VK-16
910172
910173
910174
910175
910176
910177
Order no.: 910171
LED graphic panel in an aluminium housing with hinged grid
plate and transparent front window for a user-defined layout
in between that can be replaced at any time, e.g. diagram,
plot etc. The panel allows the placement of LEDs that light up
the inserted plan at desired points, plus sensor buttons which
trigger switch functions at any place in the plan by tapping
through the front plate as on a touch panel.
Product features
•
•
Technical specifications
Output voltage
Housing material
Protection class
P31.302.520en / 01.14
Weight
Dimensions
24 V DC
Aluminium
IP 54
3050 g (6.7 lbs)
482 x 359 x 46 mm (WxHxD)
19 x 14.1 x 1.8 inch (WxHxD)
For DIN A3 insert with lock
Extensive accessories and various interfaces and
connection- and distribution boards with parallel or serial
signal inputs.
Included in delivery
1 LMT-3 LED graphic panel without attachment material.
Not included in delivery
Red LED diodes for LMT panel
Green LED diodes for LMT panel
Yellow LED diodes for LMT panel
8 LED adapter card for LMT panel
Capacitive butten for LMT panel
LED distribution board VK-16
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 3 - 4
910172
910173
910174
910175
910176
910177
Product Sheet | Detecon
Fire brigade and system accessories
Graphic panel
Red LED diodes for LMT panel
Order no.: 910172
Super bright LED prefabricated with flexible 800mm connecting cable and reverse-polarity protected sockets for safe
attachment to distributor-, adapter- or system-specific control
modules.
Included in delivery
8 LM LED red
Plastic spacer
Technical specifications
Weight
45 g (0.1 lbs)
Green LED diodes for LMT panel
Order no.: 910173
8 LM LED green
otherwise as for article no. 910172.
Yellow LED diodes for LMT panel
Order no.: 910174
8 LM LED yellow
otherwise as for article no. 910172.
8 LED adapter card for LMT panel
Order no.: 910175
Universal adapter board for 8 LEDs, with 8 pre-resistors.
Included in delivery
1 LM-LED 8/24 adapter board for 8 LEDs
Plastic spacers
Technical specifications
Signal voltage
Signal current
Weight
10 mA
31 g (0.1 lbs)
113 x 37 x 15 mm (WxHxD)
4.5 x 1.5 x 0.6 inch (WxHxD)
P31.302.520en / 01.14
Dimensions
24 V DC
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 3 - 5
Product Sheet | Detecon
Fire brigade and system accessories
Graphic panel
Capacitive button for LMT panel
Order no.: 910176
Compact capacitive sensor button as control element for
plugging into the 5 mm holes of the LM breadboard. When
approached by a finger, it switches the optocoupler output
through the front panel together with an optical status display.
It performs self-calibration to suppress environmental influences.
Included in delivery
1 Capacitive button for LMT panel
Plastic spacer
Technical specifications
Operating voltage
12 V - 24 V DC
Current consumption
Optocoupler output
Weight
Dimensions
6 mA
max. 24 V DC / 18 mA
21 g (0.05 lbs)
21 x 21 x 12 mm (BxHxT)
0.82 x 0.82 x 0.47 inch (BxHxT)
LED distribution board VK-16
Order no.: 910177
LED distribution board for 16 signal inputs and 16 x 2 LED
outputs on polarized headers, with a slot for the connection
of lamp test buttons. Input signals either positive or negative
through bidirectional optocoupler inputs.
Included in delivery
1 LED distribution board VK-16
Plastic spacer
Technical specifications
Operating voltage
Quiescent current
consumption
Current consumption per
activated output
Max. current consumption
Signal level
optocoupler inputs
Weight
4 mA
10 mA
170 mA
min. 5 V
max. 24 V
107 g (0.24 lbs)
200 x 20 x 78 mm (BxHxT)
7.87 x 0.78 x 3.07 inch (BxHxT)
P31.302.520en / 01.14
Dimensions
12 V - 24 V DC
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 3 - 6
Product Sheet | Detecon
Manual call points
DMX indoor application
Overview indoor application
Individual labeling
Detector element (inlay) DMX
Symbol (904449)
Detector element (inlay) DMX
Symbol LED (904450)
Board DMX3000 (907764)
Board DMX3000, LED
(907765)
Board DMX3000, 2GRU
(907766)
Board DMX3000, LED ext.
(907728)
Board DMX95 (907942)
Catalogue Chapter
1
---
X
---
X
---
---
---
---
4-8
---
---
---
---
X
---
X
---
---
---
4-12
---
---
---
---
---
X
---
---
---
---
X
4-2
---
---
---
---
---
---
X
---
---
---
---
X
4-3
---
---
---
---
---
---
---
---
---
---
---
---
---
4-6
X
---
---
---
X1
X1
---
X
---
---
---
---
---
---
4-15
---
---
X
---
---
X
X
1
---
X
---
X
---
---
---
---
4-9
G
X
---
X
---
---
---
---
---
---
---
---
---
---
---
---
4-10
R
G
---
---
X
---
---
---
---
---
---
X
---
X
---
---
---
4-13
X
R
A
---
---
X
---
---
---
---
---
---
X
---
---
---
---
X
4-4
VdS
EN 12094-3
ATEX
---
R
G
---
---
X
---
---
X1
X1
---
X
---
---
---
---
---
---
4-16
---
VdS
EN 12094-3
---
T
G
---
---
---
X
---
X
X
1
---
X
---
X
---
---
---
---
4-9
---
---
VdS
EN 12094-3
---
T
G
X
---
---
X
---
---
---
---
---
---
---
---
---
---
---
4-11
IP 42
---
---
VdS
EN 12094-3
---
T
G
---
---
---
X
---
---
---
---
---
X
---
X
---
---
---
4-13
903769
DMX3000 Ex
Emergency Button, blue
IP 42
---
1
22
VdS
EN 12094-3
ATEX
---
T
G
---
---
---
X
---
X1
X1
---
X
---
---
---
---
---
---
4-16
888810
DMX3000
2nd Release, green
IP 42
---
---
VdS
EN 12094-3
---
T
G
---
---
---
---
X
---
---
---
X
---
X
---
---
---
---
4-9
904464
DMX3000 LED
2nd Release, green
IP 42
---
---
VdS
EN 12094-3
X
T
G
---
---
---
---
X
---
---
---
---
X
---
X
---
---
---
4-13
904475
DMX95
2nd Release, green
IP 42
---
---
---
X
T
A
---
---
---
---
X
---
---
---
---
X
---
---
---
---
X
4-4
903768
DMX3000 Ex
2nd Release, green
IP 42
---
1
22
VdS
EN 12094-3
ATEX
---
T
G
---
---
---
---
X
---
---
---
X
---
---
---
---
---
---
4-16
903246
DMX3000
Manual Call Point, variable
IP 42
---
---
X
2
AA
R/T
G
AA
X
X
X
2
X
X
X
X
X
2
X
X
X
X
X
2
---
4-14
904478
DMX95
Manual Call Point, variable
IP 42
---
---
X
2
AA
R/T
A
AA
X2
X2
X2
X2
---
---
X
---
X
---
---
---
---
X2
4-5
904152
DMX3000 Ex
Manual Call Point, variable
IP 42
---
1
22
ATEX
X2
---
R/T
G
AA
X
1
X
X
---
---
---
---
---
---
4-17
Weatherproof enclosure
green (903791)
X
Weatherproof enclosure
blue (903780)
4-7
Weatherproof enclosure
yellow (903779)
---
Silicone-free
---
Weatherproof enclosure
red (903792)
---
Conventional (G)
Addressable (A)
---
Alarm-LED
X
Latching contact (R)
Non-Latching contact (T)
---
Ex Zone
X
Approvals/ Norms
(further approval on catalogue
page)
---
Short circuit isolator
X1
IP rating
French labeling
Replacement
X1
903639
DMX3000
Manual Call Point, red
IP 42
---
---
VdS
EN 54-11
---
R
G
---
X
---
---
---
888791
DMX3000 Manual Call Point
fire brigade, red
IP 42
---
---
---
---
R
G
---
X
---
---
---
X
904463
DMX3000 LED
Manual Call Point, red
IP 42
---
---
VdS
EN 54-11
X
R
G
---
X
---
---
---
902895
DMX95
Manual Call Point, red
IP 42
---
---
VdS
EN 54-11
X
R
A
---
X
---
---
904474
DMX95 Manual Call Point
fire brigade, red
IP 42
---
---
---
X
R
A
---
X
---
912579
KAX DIS 908r Manual
Call Point, red
IP 45
X
---
EN 54-11
X
R
A
---
---
903767
DMX3000 Ex
Manual Call Point, red
IP 42
---
1
22
VdS
EN 54-11
ATEX
---
R
G
---
888845
DMX3000
Manual Release, yellow
IP 42
---
---
VdS
EN 12094-3
---
R
G
801001
DMX3000 SF
Manual Release, yellow
IP 42
---
---
VdS
EN 12094-3
---
R
904466
DMX3000 LED
Manual Release, yellow
IP 42
---
---
VdS
EN 12094-3
X
904477
DMX95
Manual Release, yellow
IP 42
---
---
VdS
EN 12094-3
903770
DMX3000 Ex
Manual Release, yellow
IP 42
---
1
22
888821
DMX3000
Emergency Button, blue
IP 42
---
801003
DMX3000 SF
Emergency Button, blue
IP 42
904465
DMX3000 LED
Emergency Button, blue
Application
Accessories
Replacement
Manual Call Point
P31.310.000en / 01.14
Accessories
Special labeling for outside
sign
Application
1
X
2
2
2
2
X
2
X
2
2
X
1
1
1
1,2
1
X
1,2
X
2
2
2
2
= Manual Call Point is perhaps not approval compliant
X2 = Depending on the variable type of detector
AA = On request
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 4 - 1
Product Sheet | Detecon
Manual call points
DMX indoor application, addressable
DMX95 Manual Call Point, red
Order no.: 902895
Analog addressable manual call point for indoor areas,
in accordance with EN 54-11.
An additional weatherproof enclosure with seal set is
separately available.
Applicable for operation in ¿re alarm panels with Loop AP
protocol.
Addressing via DIP switches; the address can also be
modi¿ed after installation.
The white inside sign can be replaced with other labels
(see DMX indoor application, accessories). Markings or
labels which do not comply with the standard will void the
VdS and EN 54-11 approvals.
Operating instructions and address information are included
with the detector.
Technical specifications
Function
Type B, Latching Contact
Technology / protocol
Integrated
short circuit isolator
No. of detectors per loop for
mixed automatic and manual
Operating voltage
Loop AP / XP95
Operating current
230 ȝA - 300 ȝA
no
max. 126 units
17 V - 28 V DC
Alarm current
Alarm indication
IP rating (EN 60529)
with weatherproof enclosure
Enclosure material
2 mA
1 red LED
IP 42
IP 54
Diecast aluminium
Colour
RAL 3001, red
Trigger mechanism material
Operating temperature
Relative humidity
(IEC721-3-3)
Speci¿cation according to
Weight
Dimensions
PC
-20 °C to +70 °C (-4 °F to +158 °F)
0 to 95%
no condensation
EN 54-11
Included in delivery
Mounting hardware
2 cable glands M20 x 1.5
1 paper stripe “Out of order”
Not included in delivery
1 door key design “D”
173881
Connection / mounting
Connection cable
2-lead
Recommended cable, standard
747180
J-Y(ST)Y-2x2x0.8 mm
Recommended cable for circuit integrity
907940
JE-H(ST)H E30 2x2x0.8 mm
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Electrostatic shielding
Not required
Notes
The electronics does not have any isolators, appropriate
add-on modules must be taken into account.
approx. 500 g (1.1 lbs)
125 x 125 x 32.5 mm (WxHxD)
4.9 x 4.9 x 1.3 inch (WxHxD)
Approvals / marking
0786-CPD-20379
P31.310.120en / 01.14
G 205065
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 4 - 2
Product Sheet | Detecon
Manual call points
DMX indoor application, addressable
DMX95 Manual Call Point “Feuerwehr”, red
Order no.: 904474
Analog addressable manual call point for indoor areas,
similar to EN 54-11 with "FEUERWEHR" label.
An additional weatherproof enclosure with seal set is
separately available.
Applicable for operation in ¿re alarm panels with Loop AP
protocol.
Addressing via DIP switches; the address can also be
modi¿ed after installation.
The outside and the white inside sign can be replaced with
other labels (see DMX indoor application, accessories).
Operating instructions and address information are included
with the detector.
Technical specifications
Function
Included in delivery
Type B, Latching Contact
Technology / protocol
Integrated
short circuit isolator
No. of detectors per loop for
mixed automatic and manual
Operating voltage
Loop AP / XP95
Operating current
230 ȝA - 300 ȝA
Alarm current
Alarm indication
IP rating (EN 60529)
with weatherproof enclosure
Enclosure material
Colour
no
max. 126 units
17 V - 28 V DC
Operating temperature
Relative humidity
(IEC721-3-3)
Speci¿cation according to
Weight
Dimensions
Not included in delivery
1 door key design “D”
173881
2 mA
1 red LED
IP 42
IP 54
Diecast aluminium
RAL 3001, red
Trigger mechanism material
Mounting hardware
2 cable glands M20 x 1.5
1 paper stripe “Out of order”
PC
-20 °C to +70 °C (-4 °F to +158 °F)
0 to 95%
no condensation
similar to EN 54-11
approx. 500 g (1.1 lbs)
125 x 125 x 32.5 mm (WxHxD)
4.9 x 4.9 x 1.3 inch (WxHxD)
Connection / mounting
Connection cable
2-lead
Recommended cable, standard
747180
J-Y(ST)Y-2x2x0.8 mm
Recommended cable for circuit integrity
907940
JE-H(ST)H E30 2x2x0.8 mm
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Electrostatic shielding
Not required
Notes
The electronics does not have any isolators, appropriate addon modules must be taken into account.
This MCP uses German labelling. For other languages
please use Order no. 904478
P31.310.120en / 01.14
Approvals / marking
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 4 - 3
Product Sheet | Detecon
Manual call points
DMX indoor application, addressable
DMX95 Manual Release, yellow
Order no.: 904477
Technical specifications
Approvals / marking
Function
Type B, Latching Contact
Colour
RAL 1021, yellow
Speci¿cation according to
EN 12094-3
G 208061
0786-CPD-20380
Otherwise like Order no. 902895
Markings or labels which do not comply with the standard will
void the VdS and EN 12094-3 approvals.
Notes
This MCP uses German labelling. For other languages
please use Order no. 904478
DMX95 2nd Release, green
Order no.: 904475
Technical specifications
Approvals / marking
Function
Type B, Non-Latching Contact
Colour
RAL 6002, green
Speci¿cation similar to:
EN 12094-3
Otherwise like Order no. 902895
Notes
P31.310.120en / 01.14
This MCP uses German labelling. For other languages
please use Order no. 904478
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 4 - 4
Product Sheet | Detecon
Manual call points
DMX indoor application, addressable
DMX95 Manual Call Point, variable
Order no.: 904478
Technical specifications
Analog addressable manual call point for indoor areas,
similar to EN 54-11 or EN 12094-3.
Free selection of the detector configuration possible
(Latching or non-latching contact, silicone free, special
labeling).
The order is placed along with an additional note on the
detector, with order number and the desired modi¿cations.
Production is then performed with manual machining by
the process engineering department at the lead plant in
Bad Oldesloe. In addition to process engineering, a contract
review is performed in order to comply with regulations.
Function
Technology / protokol
Integrated
short circuit isolator
No. of detectors per loop for
mixed automatic and manual
Operating voltage
Operating current
Alarm current
Alarm indication
IP rating (EN 60529)
with weatherproof enclosure
Enclosure material
Colour
Trigger mechanism material
Operating temperature
Relative humidity
(IEC721-3-3)
Speci¿cation according to
Weight
Dimensions
P31.310.120en / 01.14
Approvals / marking
Type B,
Latching or Non-Latching Contact
Loop AP / XP95
no
Max. 126 units
17 V - 28 V DC
230 ȝA - 300 ȝA
2 mA
1 red LED
IP 42
IP 54
Diecast aluminium
RAL 3001, red
RAL 1021, yellow
RAL 5015, blue
RAL 6002, green
PC
-20 °C to +70 °C (-4 °F to +158 °F)
0 to 95%
no condensation
similar to EN 54-11
EN 12094-3
approx. 500 g (1.1 lbs)
125 x 125 x 32.5 mm (WxHxD)
4.9 x 4.9 x 1.3 inch (WxHxD)
An additional weatherproof enclosure with seal set is
separately available.
Applicable for operation in ¿re alarm panels with Loop AP
protocol. Addressing via DIP switches; the address can also
be modi¿ed after installation.
Operating instructions and address information are included
with the detector.
Included in delivery
Mounting hardware
2 cable glands M20 x 1.5
1 paper stripe “Out of order”
Not included in delivery
1 door key design “D”
173881
Connection / mounting
Connection cable
2-lead
Recommended cable, standard
747180
J-Y(ST)Y-2x2x0.8 mm
Recommended cable for circuit integrity
907940
JE-H(ST)H E30 2x2x0.8 mm
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Electrostatic shielding
Not required
Note
The electronics does not have any isolators, appropriate addon module must be taken into account.
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 4 - 5
Product Sheet | Detecon
Manual call points
DMX indoor application, addressable
KAX DIS 908r Manual Call Point, red
Order no.: 912579
Analog addressable manual call point with intagreated
isolator for indoor areas, in accordance with EN 54-11.
Applicable for operation in ¿re alarm panels with Loop AP
protocol.
Addressing via DIP switches; the address can also be
modi¿ed after installation.
Markings or labels which do not comply with the standard will
void the EN 54-11 approval.
Operating instructions and address information are included
with the detector.
Included in delivery
1 key to reset / open the MCP
Technical specifications
Function
Not included in delivery
Type A, Latching Contact
Technology protokol
Integrated
short circuit isolator
No. of detectors per loop for
mixed automatic and manual
Operating voltage
Operating current
Alarm current
Alarm indication
IP rating (EN 60529)
Enclosure material
Colour
Operating temperature
Relative humidity
(IEC721-3-3)
Speci¿cation according to
Weight
Dimensions
Mounting hardware
Loop AP / Discovery
yes
max. 126 units
17 V - 28 V DC
100 ȝA
4 mA
1 LED, red
Connection / mounting
Connection cable
2-lead
Recommended cable, standard
747180
J-Y(ST)Y-2x2x0.8 mm
Recommended cable for circuit integrity
907940
JE-H(ST)H E30 2x2x0.8 mm
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Electrostatic shielding
Not required
IP 45
PC / ABS
red
-40 °C to + 70 °C
(-40 °F to +158 °F)
0 to 95%
no condensation
EN 54-11
approx. 180 g ( 6.6 lbs)
88 x 88 x 59 mm (WxHxD)
3.5 x 3.5 x 2.3 inch (WxHxD)
Approvals / marking
P31.310.120en / 01.14
0832-CPD-2033
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 4 - 6
Product Sheet | Detecon
Manual call points
DMX indoor application, conventional
DMX3000 Manual Call Point, red
Order no.: 903639
Manual call point for indoor areas, conventional detector in
accordance with EN 54-11.
An additional weatherproof enclosure with seal set is
separately available.
Applicable alarm for operation on conventional lines of the
¿re alarm panels FMZ4100 and FMZ5000.
The printed symbol (burning house) and the white inside
panel comply with EN 54-11.
The white inside sign can be replaced with other labels (see
DMX indoor application, accessories).
Markings or labels which do not comply with the standard will
void the VdS and EN 54-11 approvals.
Operating instructions and connection notes are included
with the detector.
Technical specifications
Function
Type B, Latching Contact
Technology
Conventional
Rated voltage
9V
Operating voltage
7.6 V - 13.2 V DC
Quiescent current
5 mA (at 9 V)
Alarm current
IP rating (EN 60529)
with weatherproof enclosure
Enclosure material
20 mA (at 9 V)
IP 42
IP 54
Diecast aluminium
Colour
RAL 3001, red
Trigger mechanism material
Operating temperature
Relative humidity (IEC721-3-3)
Speci¿cation according to
Cable entry
Weight
Dimensions
PC
-30 °C to +70 °C
(-22 °F to +158 °F)
0 to 95%
no condensation
EN 54-11
Included in delivery
Mounting hardware
2 cable glands M20 x 1.5
1 paper stripe “Out of order”
Not included in delivery
1 door key design “D”
173881
Connection / mounting
Connection cable
2-lead
Recommended cable, standard
747180
J-Y(ST)Y-2x2x0.8 mm
Recommended cable for circuit integrity
907940
JE-H(ST)H E30 2x2x0.8 mm
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Electrostatic shielding
Not required
2 x M20 x 1.5 mm (0.06 inch)
approx. 500 g (1.1 lbs)
125 x 125 x 32.5 mm (WxHxD)
4.9 x 4.9 x 1.3 inch (WxHxD)
Approvals / marking
0786-CPD-20347
P31.310.110en / 01.14
G 297003
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 4 - 7
Product Sheet | Detecon
Manual call points
DMX indoor application, conventional
DMX3000 Manual Call Point “Feuerwehr”,
red
Order no.: 888791
Conventional manual call point for indoor areas, similar to EN
54-11. Labelling “FEUERWEHR” deviates from the standard.
An additional weatherproof enclosure with seal set is separately available. Applicable for operation on conventional
lines of the ¿re alarm panels FMZ4100 and FMZ5000.
The outside and the white inside sign can be replaced with
other labels (see DMX indoor application, accessories). Operating instructions and connection notes are included with
the detector.
Included in delivery
Mounting hardware
2 cable glands M20 x 1.5
1 paper stripe “Out of order”
Technical specifications
Function
Type B, Latching Contact
Technology
Rated voltage
Conventional
9V
Operating voltage
7.6 V - 13.2 V DC
Quiescent current
5 mA (at 9 V)
Alarm current
IP rating (EN 60529)
with weatherproof enclosure
Enclosure material
Colour
20 mA (at 9 V)
IP 42
IP 54
Diecast aluminium
RAL 3001, red
Trigger mechanism material
Operating temperature
Relative humidity
(IEC721-3-3)
Speci¿cation similar to:
Cable entry
Weight
Dimensions
PC
-30 °C to +70 °C
(-22 °F to +158 °F)
0 to 95%
no condensation
EN 54-11
Not included in delivery
1 door key design “D”
173881
Connection / mounting
Connection cable
2-lead
Recommended cable, standard
747180
J-Y(ST)Y-2x2x0.8 mm
Recommended cable for circuit integrity
907940
JE-H(ST)H E30 2x2x0.8 mm
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Electrostatic shielding
Not required
Notes
This MCP is labeled in German. For other languages please
use the Order no. 903246
2 x M20 x 1.5 mm (0.06 inch)
approx. 500 g ( 1.1 lbs)
125 x 125 x 32.5 mm (WxHxD)
4.9 x 4.9 x 1.3 inch (WxHxD)
P31.310.110en / 01.14
Approvals / marking
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 4 - 8
Product Sheet | Detecon
Manual call points
DMX indoor application, conventional
DMX3000 Manual Release, yellow
Order no.: 888845
Technical specifications
Function
Otherwise like Order no. 903639
Type B, Latching Contact
Colour
RAL 1021, yellow
Speci¿cation according to
EN 12094-3
Notes
Approvals / marking
G 207141
This MCP uses German labelling. For other languages
please use the Order no. 903246
0786-CPD-20349
DMX3000 Emergency Button, blue
Order no.: 888821
Technical specifications
Otherwise like Order no. 903639
Function
Type B, Non-Latching Contact
Colour
RAL 5015, blue
Speci¿cation according to
EN 12094-3
G 207143
Markings or labels which do not comply with the standard will
void the VdS and EN 12094-3 approvals.
Notes
This MCP uses German labelling. For other languages
please use the Order no. 903246
Approvals / marking
0786-CPD-20348
DMX3000 2nd Release, green
Order no.: 888810
Technical specifications
Otherwise like Order no. 903639
Function
Type B, Non-Latching Contact
Colour
RAL 6002, green
Speci¿cation similar to:
P31.310.110en / 01.14
Markings or labels which do not comply with the standard will
void the VdS and EN 12094-3 approvals.
Markings or labels which do not comply with the standard will
void the VdS approval.
EN 12094-3
Notes
Approvals / marking
This MCP uses German labelling. For other languages
please use the Order no. 903246
G 207143
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 4 - 9
Product Sheet | Detecon
Manual call points
DMX indoor application, conventional
DMX3000 SF Manual Release, yellow
Order no.: 801001
Conventional manual call point for indoor areas, in
accordance with EN 12094-3 at silicone-free design.
An additional weatherproof enclosure with seal set is
separately available.
Applicable for operation on conventional lines of the ¿re
alarm panels FMZ4100 and FMZ5000.
Labelling in accordance with EN12094-3.
The outside sign and the white inside sign can be replaced
with other labels (see DMX indoor application, accessories).
Markings or labels which do not comply with the standard will
void the VdS and EN 12094-3 approvals.
Operating instructions and connection notes are included
with the detector.
Included in delivery
Technical specifications
Function
Type B, Latching Contact
Technology
Conventional
Rated voltage
9V
Operating voltage
7.6 V - 13.2 V DC
Quiescent current
5 mA (at 9 V)
Alarm current
IP rating (EN 60529)
with weatherproof enclosure
Enclosure material
20 mA (at 9 V)
IP 42
IP 54
Diecast aluminium
Colour
RAL 1021, yellow
Trigger mechanism material
PC
-30 °C to +70 °C
(-22 °F to +158 °F)
0 to 95%
no condensation
EN 12094-3
Operating temperature
Relative humidity
(IEC721-3-3)
Speci¿cation according to
SF
Silicone-free design
Weight
Dimensions
Mounting hardware
2 cable glands M20 x 1.5
1 paper stripe “Out of order”
Not included in delivery
1 door key design “D”
173881
Connection / mounting
Connection cable
2-lead
Recommended cable, standard
747180
J-Y(ST)Y-2x2x0.8 mm
Recommended cable for circuit integrity
907940
JE-H(ST)H E30 2x2x0.8 mm
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Electrostatic shielding
Not required
Notes
This MCP uses German labelling. For other languages
please use the Order no. 903246
approx. 500 g (1.1 lbs)
125 x 125 x 32.5 mm (WxHxD)
4.9 x 4.9 x 1.3 inch (WxHxD)
Approvals / marking
0786-CPD-20349
P31.310.110en / 01.14
G 207141
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 4 - 10
Product Sheet | Detecon
Manual call points
DMX indoor application, conventional
DMX3000 SF Emergency Button, blue
Order no.: 801003
Technical specifications
Otherwise like Order no. 801001
Function
Type B, Non-Latching Contact
Colour
RAL 5015, blue
Speci¿cation according to
EN 12094-3
Notes
This MCP uses German labelling. For other languages
please use the Order no. 903246
Approvals / marking
0786-CPD-20348
P31.310.110en / 01.14
G 207143
Markings or labels which do not comply with the standard will
void the VdS and EN 12094-3 approvals.
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 4 - 11
Product Sheet | Detecon
Manual call points
DMX indoor application, conventional
DMX3000 LED Manual Call Point, red
Order no.: 904463
Conventional manual call point with red alarm indication
(LED) for indoor areas, in accordance with EN 54-11.
An additional weatherproof enclosure with seal set is
separately available for.
Applicable for operation on conventional lines alarm panels
FMZ 4100 and FMZ 5000.
The printed symbol (burning house) and the white inside
panel are designed in accordance with EN 54-11.
The white inside sign can be replaced with other labels
(see DMX indoor application, accessories).
Markings or labels which do not comply with the standard will
void the VdS and EN 54-11 approvals.
Operating instructions and connection notes are included
with the detector.
Technical specifications
Function
Type B, Latching Contact
Technology
Conventional
Rated voltage
9V
Operating voltage
7.6 V - 13.2 V DC
Quiescent current
5 mA (at 9 V)
Alarm current
IP rating (EN 60529)
with weatherproof enclosure
Enclosure material
20 mA (at 9 V)
IP 42
IP 54
Diecast aluminium
Colour
RAL 3001, red
Trigger mechanism material
Operating temperature
Relative humidity
(IEC721-3-3)
Speci¿cation according to
LED
Weight
Dimensions
PC
-30 °C to +70 °C
(-22 °F to +158 °F)
0 to 95%
no condensation
EN 54-11
Lights up red
when button is pressed
approx. 500 g (1.1 lbs)
125 x 125 x 32.5 mm (WxHxD)
4.9 x 4.9 x 1.3 inch (WxHxD)
Included in delivery
Mounting hardware
2 cable glands M20 x 1.5
1 paper stripe “Out of order”
Not included in delivery
1 door key design “D”
173881
Connection / mounting
Connection cable
2-lead
Recommended cable, standard
747180
J-Y(ST)Y-2x2x0.8 mm
Recommended cable for circuit integrity
907940
JE-H(ST)H E30 2x2x0.8 mm
Conducter cross-section max. 2.5 mm2 (0.004 square inch)
Electrostatic shielding
Not required
Approvals / marking
0786-CPD-20347
P31.310.110en / 01.14
G 297003
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 4 - 12
Product Sheet | Detecon
Manual call points
DMX indoor application, conventional
DMX3000 LED Manual Release, yellow
Order no.: 904466
Technical specifications
Otherwise like Order no. 904463
Function
Type B, Latching Contact
Colour
RAL 1021, yellow
Speci¿cation according to
EN 12094-3
0786-CPD-20349
DMX3000 LED Emergency Button, blue
Order no.: 904465
Technical specifications
Otherwise like Order no. 904463
Function
Type B, Non-Latching Contact
Colour
RAL 5015, blue
Speci¿cation according to
EN 12094-3
G 207143
Markings or labels which do not comply with the standard will
void the VdS and EN 12094-3 approvals.
Notes
This MCP uses German labelling. For other languages
please use the Order no. 903246
Approvals / marking
0786-CPD-20348
DMX3000 LED 2nd Release, green
Order no.: 904464
Technical specifications
Otherwise like Order no. 904463
Function
Type B, Non-Latching Contact
Colour
RAL 6002, green
Speci¿cation similar to:
Approvals / marking
P31.310.110en / 01.14
Notes
This MCP uses German labelling. For other languages
please use the Order no. 903246
Approvals / marking
G 207141
Markings or labels which do not comply with the standard will
void the VdS and EN 12094-3 approvals.
EN 12094-3
Markings or labels which do not comply with the standard will
void the VdS approval.
Notes
This MCP uses German labelling. For other languages
please use the Order no. 903246
G 207143
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 4 - 13
Product Sheet | Detecon
Manual call points
DMX indoor application, conventional
DMX3000 Manual Call Point, variable
Order no.: 903246
Technical specifications
Conventional manual call point for indoor areas, similar to EN
54-11 or EN 12094-3.
Free selection of the detector configuration possible
(Latching or non-latching contact, silicone free, special
labeling). The order are placed with an additional note on
the detector with order no. and the desired modi¿cations.
Production is then performed with manual machining by
the process engineering department at the lead plant in
Bad Oldesloe. In addition to process engineering, a contract
review is performed in order to comply with regulations.
An additional weatherproof enclosure with seal set is
separately available.
Applicable for operation on conventional lines of the ¿re
alarm panels FMZ 4100 and FMZ 5000.
Operating instructions and connection notes are included
with the detector.
Function
Technology
Rated voltage
Operating voltage
Quiescent current
Alarm current
IP rating (EN 60529)
with weatherproof enclosure
Enclosure material
Colour
Trigger mechanism material
Operating temperature
Relative humidity
(IEC721-3-3)
Speci¿cation similar to:
Weight
Dimensions
9V
7.6 V - 13.2 V DC
5 mA (at 9 V)
20 mA (at 9 V)
IP 42
IP 54
Diecast aluminium
RAL 3001, red
RAL 1021, yellow
RAL 5015, blue
RAL 6002, green
PC
-30 °C to +70 °C
(-22 °F to +158 °F)
0 to 95%
no condensation
EN 54-11
EN 12094-3
approx. 500 g (1.1 lbs)
125 x 125 x 32.5 mm (WxHxD)
4.9 x 4.9 x 1.3 inch (WxHxD)
Included in delivery
Mounting hardware
2 cable glands M20 x 1.5
1 paper stripe “Out of order”
Not included in delivery
1 door key design “D”
173881
Connection / mounting
Connection cable
2-lead
Recommended cable, standard
747180
J-Y(ST)Y-2x2x0.8 mm
Recommended cable for circuit integrity
907940
JE-H(ST)H E30 2x2x0.8 mm
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Electrostatic shielding
Not required
P31.310.110en / 01.14
Approvals / marking
Type B,
Latching or Non-Latching Contact
Conventional
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 4 - 14
Product Sheet | Detecon
Manual call points
DMX indoor application, Ex
DMX3000 Ex Manual Call Point, red
Order no.: 903767
Technical specifications
Function
Type B, Latching Contact
Technology
Conventional
Rated voltage
9V
Operating voltage
7.6 V - 13.2 V DC
Quiescent current
5 mA (at 9 V)
Alarm current
20 mA (at 9 V)
Ci = 12 nF
Effective inner capacity
Li = negligible
IP 42
IP 54
Diecast aluminium
Effective inner inductance
IP rating (EN 60529)
with weatherproof enclosure
Enclosure material
Colour
RAL 3001, red
Trigger mechanism material
Operating temperature in
temperature class T6
Operating temperature in
temperature class T4
Relative humidity
(IEC721-3-3)
Speci¿cation according to
PC
-25 °C to +40 °C
(-13 °F to +104 °F)
-25 °C to +70 °C
(-13 °F to +158 °F)
0 to 95%
no condensation
EN 54-11
Ex zone
Zone 1 (gas) and 22 (dust)
Weight
Dimensions
Conventional manual call point for indoor areas in Ex zone 1
or 22 in accordance with EN 54-11.
An additional weatherproof enclosure with seal set is available.
Applicable for operation on conventional lines of the ¿re
alarm panels FMZ 4100 and FMZ 5000.
The printed symbol (house on ¿re) and the white inside panel
are designed in accordance with EN 54-11. The white inside
sign can be replaced with other labels (see DMX indoor application, accessories)
Markings or labels which do not comply with the standard will
void the VdS and EN 54-11 approvals.
The Ex manual call point may only be used together with a
safety barrier (see FMZ 5000 modules/cards) and a blue ¿re
alarm cable.
Operating instructions and connection notes are included
with the detector.
Included in delivery
Mounting hardware
2 cable glands M20 x 1.5
1 paper stripe “Out of order”
Not included in delivery
Safety barrier IS conventional 9 V
1 door key design “D”
Connection / mounting
Connection cable
2-lead
Recommended cable for Ex devices
140084
JE-Y(ST)Y-2x2x0.8 mm, blue
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Electrostatic shielding
Not required
Note
The call point´s metal casing is part of the local potential
equalisation.
approx. 500 g (1.1 lbs)
125 x 125 x 32.5 mm (WxHxD)
4.9 x 4.9 x 1.3 inch (WxHxD)
Approvals / marking
Ex conformity in acc. with 94/9/EC
P31.310.130en / 01.14
x II 2G Ex ib IIC T6...T4 Gb
x II 3D Ex ib IIIB T120°C Dc
Ex conformity Russia in acc. with TP TC 012/2011:
1Ex ia IIC T6/T4 Gb
G 297003
904991
173881
0786-CPD-20347
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 4 - 15
Product Sheet | Detecon
Manual call points
DMX indoor application, Ex
DMX3000 Ex Manual Release, yellow
Order no.: 903770
Technical specifications
Approvals / marking
Function
Type B, Latching Contact
Colour
Ex conformity in acc. with 94/9/EC
x II 2G Ex ib IIC T6...T4 Gb
x II 3D Ex ib IIIB T120°C Dc
RAL 1021, yellow
Speci¿cation according to
EN 12094-3
Markings or labels which do not comply with the standard will
void the VdS and EN 12094-3 approvals.
Ex conformity Russia in acc. with TP TC 012/2011:
1Ex ia IIC T6/T4 Gb
G 207141
0786-CPD-20349
Notes
This MCP uses German labelling. For other languages
please use the Order no. 904152
Otherwise like Order no.: 903767
DMX3000 Ex Emergency Button, blue
Order no.: 903769
Technical specifications
Approvals / marking
Function
Type B, Non-Latching Contact
Colour
Speci¿cation according to
Ex conformity in acc. with 94/9/EC
RAL 5015, blue
x II 2G Ex ib IIC T6...T4 Gb
x II 3D Ex ib IIIB T120°C Dc
EN 12094-3
Ex conformity Russia in acc. with TP TC 012/2011:
1Ex ia IIC T6/T4 Gb
Markings or labels which do not comply with the standard will
void the VdS and EN 12094-3 approvals.
G 207143
0786-CPD-20348
Notes
This MCP uses German labelling. For other languages
please use the Order no. 904152
Otherwise like Order no.: 903767
DMX3000 Ex 2nd Release, green
Order no.: 903768
Technical specifications
Approvals / marking
Function
Type B, Non-Latching Contact
Colour
x II 2G Ex ib IIC T6...T4 Gb
x II 3D Ex ib IIIB T120°C Dc
RAL 6002, green
Speci¿cation similar to:
P31.310.130en / 01.14
Ex conformity in acc. with 94/9/EC
EN 12094-3
Markings or labels which do not comply with the standard will
void the VdS approval.
Ex conformity Russia in acc. with TP TC 012/2011:
1Ex ia IIC T6/T4 Gb
G 207143
Notes
This MCP uses German labelling. For other languages
please use the Order no. 904152
Otherwise like Order no.: 903767
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 4 - 16
Product Sheet | Detecon
Manual call points
DMX indoor application, Ex
DMX3000 Ex Manual Call Point, variable
Order no.: 904152
Technical specifications
Conventional manual call point for indoor areas in Ex zone 1
or 22, similar to EN 54-11 or EN 12094-3.
Function
Technology
Type B,
Latching or Non-Latching Contact
Conventional
Rated voltage
9V
Operating voltage
7.6 V - 13.2 V DC
Quiescent current
5 mA (at 9 V)
Alarm current
20 mA (at 9 V)
Ci = 12 nF
Effective inner capacity
Effective inner inductance
IP rating (EN 60529)
with weatherproof enclosure
Enclosure material
Li = negligible
IP 42
IP 54
Diecast aluminium
RAL 3001, red
RAL 1021, yellow
RAL 5015, blue
RAL 6002, green
PC
-25 °C to +40 °C
(-13 °F to +104 °F)
-25 °C to +70 °C
(-13 °F to +158 °F)
0 to 95%
no condensation
EN 54-11
EN 12094-3
Zone 1 (gas) and 22 (dust)
Colour
Trigger mechanism material
Operating temperature in
temperature class T6
Operating temperature in
temperature class T4
Relative humidity
(IEC721-3-3)
Speci¿cation similar to:
Ex zone
Weight
Dimensions
approx. 500 g (1.1 lbs)
125 x 125 x 32.5 mm (WxHxD)
4.9 x 4.9 x 1.3 inch (WxHxD)
Approvals / marking
P31.310.130en / 01.14
Ex conformity in acc. with 94/9/EC
x II 2G Ex ib IIC T6...T4 Gb
x II 3D Ex ib IIIB T120°C Dc
Ex conformity Russia in acc. with TP TC 012/2011:
1Ex ia IIC T6/T4 Gb
Free selection of detector configuration possible
(Latching or non-latching contact, silicone free, special
labeling). The order is placed along with an additional
note on the detector, with order number and the desired
modi¿cations.
Production is then performed with manual machining by
the process engineering department at the lead plant in
Bad Oldesloe. In addition to process engineering, a contract
review is performed in order to comply with regulations.
An additional weatherproof enclosure with seal set is
available.
Applicable for operation on conventional lines ¿re alarm
panels FMZ 4100 and FMZ 5000.
The Ex manual call point may only be used together with a
safety barrier (see FMZ 5000 modules/cards) and a blue ¿re
alarm cable.
Operating instructions and connection notes are included
with the detector.
Included in delivery
Mounting hardware
2 cable glands M20 x 1.5
1 paper stripe “Out of order”
Not included in delivery
Safety barrier IS conventional 9 V
1 door key design “D”
904991
173881
Connection / mounting
Connection cable
2-lead
Recommended cable for Ex devices
140084
JE-Y(ST)Y-2x2x0.8 mm, blue
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Electrostatic shielding
Not required
Note
The call point´s metal casing is part of the local potential
equalisation.
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 4 - 17
Product Sheet | Detecon
Manual call points
DMX indoor application, accessories
Weatherproof enclosure, red
Order no.: 903792
Technical specifications
Colour
RAL 3001, red
Weight
0.28 kg (0.1 lbs)
With the weatherproof enclosure, the protection rating rises
from IP42 to IP54 for the manual call points DMX3000,
DMX3000 Ex and DMX95.
Included in delivery
Weatherproof enclosure with seal set and gland M 20 x 1.5.
Weatherproof enclosure, yellow
Order no.: 903779
Technical specifications
With the weatherproof enclosure, the protection rating rises
from IP42 to IP54 for the manual call points DMX3000,
DMX3000 Ex and DMX95.
Colour
RAL 1021, yellow
Weight
0.28 kg (0.1 lbs)
Included in delivery
Weatherproof enclosure with seal set and gland M 20 x 1.5.
Weatherproof enclosure, blue
Order no.: 903780
Technical specifications
With the weatherproof enclosure, the protection rating rises
from IP42 to IP54 for the manual call points DMX3000,
DMX3000 Ex and DMX95.
Colour
RAL 5015, blue
Weight
0.28 kg (0.1 lbs)
Included in delivery
Weatherproof enclosure with seal set and gland M 20 x 1.5.
Weatherproof enclosure, green
Order no.: 903791
Technical specifications
With the weatherproof enclosure, the protection rating rises
from IP42 to IP54 for the manual call points DMX3000,
DMX3000 Ex and DMX95.
RAL 6002, green
Weight
0.28 kg (0.1 lbs)
Included in delivery
Weatherproof enclosure with seal set and gland M 20 x 1.5.
P31.310.140en / 02.13
Colour
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 4 - 18
Product Sheet | Detecon
Manual call points
DMX indoor application, accessories
Order no.: 904449
Detector element DMX symbol LED
Order no.: 904450
DMX3000 card
Order no.: 907764
DMX3000 card, LED
Order no.: 907765
DMX3000 card, 2GRU
Order no.: 907766
DMX3000 card, LED ext.
Order no.: 907728
DMX95 card
Order no.: 907942
Special labelling for outside and
inside sign,
Order no.: 903371
French labelling
Order no.: 904292
P31.310.140en / 02.13
Detector element DMX symbol
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 4 - 19
Product Sheet | Detecon
Manual call points
DMX outdoor application
Overview outdoor application
Short circuit isolator
Ex Zone
Approvals/ Norms
(further approval on
catalogue page)
Alarm-LED
Latching contact (R)
Non-Latching contact (T)
Conventional (G)
Addressable (A)
Silicone-free
Special labeling for white
inside panel (907192)
Individual labeling
(outside)
Board DMX3100 SUX95,
switch (907890)
Board DMX3100 SUX95,
button (907912)
Board DMX3100,
switch (907883)
Board DMX3100,
button (907884)
Board DMX3100,
2GRU, switch (907887)
Board DMX3100,
ZDP, switch (907886)
Board DMX3100, SUX50,
switch (907889)
Catalogue chapter
Replacement
906939
DMX3100
Manual Call Point, red
IP 66
---
---
VdS
EN 54-11
---
R
G
---
X
1
---
---
---
X
---
---
---
---
4-28
908622
DMX3195-I
Manual Call Point, red
IP 66
X
---
VdS
EN 54-11
EN 54-17
---
R
A
---
X1
---
---
---
---
---
---
---
---
4-21
IP 66
X
---
__
---
R
A
---
X
BA
---
---
---
---
---
---
---
4-23
912580
KAX DIS 951r WP
Manual Call Point, red
IP 67
X
---
X
R
A
---
---
---
---
---
---
---
---
---
---
4-27
908711
dc31 Ex
Manual Call Point, red
IP 66
---
1
21
VdS
EN 54-11
ATEX
---
R
G
---
X1
---
---
---
---
---
---
---
---
4-34
901321
KAX95 Ex
Manual Call Point, red
IP 67
---
0
EN 54-11
ATEX
X
R
A
---
---
---
---
---
---
---
---
---
---
4-32
906940
DMX3100
Manual Release, yellow
IP 66
---
---
VdS
EN 12094-3
---
R
G
---
X
1
---
---
---
X
---
---
---
---
4-29
907024
DMX3100 2GRU
Manual Release, yellow
IP 66
---
---
VdS
EN 12094-3
---
R
G
---
X1
---
---
---
---
---
X
---
---
4-30
908623
DMX3195-I
Manual Release, yellow
IP 66
X
---
VdS
EN 12094-3
EN 54-17
---
R
A
---
X
1
LU
---
---
---
---
---
---
---
4-22
IP 66
X
---
---
---
R
A
---
X
1
BA
---
---
---
---
---
---
---
4-24
908712
dc31 Ex
Manual Release, yellow
IP 66
---
1
21
VdS
EN 12094-3
ATEX
---
R
G
---
X1
---
---
---
---
---
---
---
---
4-35
912581
KAX95 Ex
Manual Release, yellow
IP 67
---
0
ATEX
X
R
A
---
---
---
---
---
---
---
---
---
---
4-33
907021
DMX3100
Emergency Button, blue
IP 66
---
---
VdS
EN 12094-3
---
T
G
---
X
1
---
---
---
---
X
---
---
---
4-29
IP 66
X
---
---
---
T
A
---
X
1
BA
---
---
---
---
---
---
---
4-25
908713
dc31 Ex
Emergency Button, blue
IP 66
---
1
21
VdS
EN 12094-3
ATEX
---
T
G
---
X
1
---
---
---
---
---
---
---
---
4-35
907022
DMX3100
2nd Release, green
IP 66
---
---
VdS
EN 12094-3
---
T
G
---
X
1
---
---
---
---
X
---
---
---
4-29
IP 66
X
---
---
---
T
A
---
X
1
BA
---
---
---
---
---
---
---
4-25
908714
dc31 Ex
2nd Release, green
IP 66
---
1
21
VdS
EN 12094-3
ATEX
---
T
G
---
X
1
---
---
---
---
---
---
---
---
4-35
909032
DMX3100
variable
IP 66
---
---
X2
---
X
2
G
AA
X
1
X
1
---
---
X
2
---
---
---
4-31
910725
DMX3195-I
variable
IP 66
X
2
---
X2
---
X
2
A
AA
X
1
X
1
---
---
---
---
---
---
---
4-26
---
---
---
---
---
---
---
---
---
Application
Accessories
Replacement
Manual Call Point
900815
DMX3195-I, red
910553
DMX3195-I, yellow
910554
DMX3195-I, blue
910824
DMX3195-I, green
P31.310.000en / 01.14
Accessories
IP rating
Application
Older DMX versions
X
1
= Manual Call Point is perhaps not approval compliant
X
2
= Depending on the variable type of detector
EN 54-11
1
---
X
2
X
2
X
2
2
X
X
2
X
2
X
2
X
2
---
AA = On request
LU = Included in delivery (see labeling table at the product page)
BA = Inforamtion about the labeling required
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 4 - 20
Product Sheet | Detecon
Manual call points
DMX outdoor application, addressable
DMX3195-I Manual Call Point, red
Order no.: 908622
Analogue addressable manual call point for outdoor areas,
in accordance with EN 54-11.
Applicable for operation in ¿re alarm panels with Loop AP
protocol.
Addressing via DIP switches; the address can also be
modi¿ed after installation.
The detector has a built-in isolator.
If the labelling does not comply with VdS or EN 54-11
standards, the order no. 910815 or 910725 must be used.
The white internal plate can be replaced by other labelling
(see DMX External application accessories).
If the labelling does not comply with applicable standards, the
VdS and EN 54-11 approvals will void.
Technical specifications
Function
Included in delivery
Type B, Latching Contact
Technology / protocol
Integrated
short circuit isolator
Operating voltage
Loop AP / XP95
yes
17 V - 28 V DC
Operating current
200 ȝA
Starting current (max.)
1 mA
IP rating (EN 60529)
IP 66
Enclosure material
PC
Colour
RAL 3001, red
Trigger mechanism material
Operating temperature
Relative humidity
(IEC721-3-3)
Speci¿cation according to
Weight
Dimensions
Mounting hardware
1 door key
2 cable glands M20 x 1.5
1 blanking plug
POM
-20 °C to +60 °C (-4 °F to +140 °F)
0 to 95%
no condensation
EN 54-11
Connection / mounting
Connection cable
2-lead
Recommended cable, standard
747180
J-Y(ST)Y-2x2x0.8 mm
Recommended cable for circuit integrity
907940
JE-H(ST)H E30 2x2x0.8 mm
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Electrostatic shielding
Not required
Note
Strong magnetic ¿elds should be avoided in the vicinity of the
detectors.
526 g (1.2 lbs)
135 x 161 x 61 mm (WxHxD
5.3 x 6.3 x 2.4 inch (WxHxD))
Approvals / marking
0786-CPD-21146
P31. 310.320en / 01.14
G 211004
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 4 - 21
Product Sheet | Detecon
Manual call points
DMX outdoor application, addressable
DMX3195-I Manual Release, yellow
Order no.: 908623
Technical specifications
The manual call point in the yellow enclosure according to
EN 12094-3 can be used for the electrical triggering of gas
extinguishing systems.
If the labeling does not comply with VdS or EN 12094-3, the
order no. 910553 or 910725 must be used.
Function
Type B, Latching Contact
Colour
similar RAL 1021, yellow
Speci¿cation according to
EN 12094-3
If the labeling does not comply with applicable standards, the
VdS and EN 12094-3 approvals will void.
Excerpt from label texts
Included in delivery
Mounting hardware
2 cable glands M20 x 1.5
1 door key
1 blanking plug
1 Labelling kit (multilingual) with 14 labels
see excerpt from label texts.
Note
The labelling kit (multilingual) complies with EN 12094-3 for
national and international applications.
Approvals / marking
0786-CPD-21147
P31. 310.320en / 01.14
G 211011
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 4 - 22
Product Sheet | Detecon
Manual call points
DMX outdoor application, addressable
DMX3195-I, red
Order no.: 910815
Analog addressable manual call point for outdoor areas similar to EN 54-11. Applicable for operation in ¿re alarm panels
with Loop AP protocol.
Addressing via DIP switches. The address can also be modi¿ed after installation.
The detector has a built-in isolator.
For use of the manual call point in other applications, such as
„Fire alarm“, the inscription label is af¿xed on the enclosure
by the factory. The white internal plate can be replaced by
other labelling (see DMX External application accessories).
In case of order the arbitrary/variable label text it is to be
indicated under „Information for production“.
Included in delivery
Technical specifications
Function
Type B, Latching Contact
Technology / protocol
Integrated
short circuit isolator
Operating voltage
Operating current
yes
17 V - 28 V DC
200 ȝA
Starting current (max.)
1 mA
IP rating (EN 60529)
IP 66
Enclosure material
Colour
PC
similar to RAL 3001, red
Trigger mechanism material
Operating temperature
Relative humidity
(IEC721-3-3)
Weight
Dimensions
P31. 310.320en / 01.14
Loop AP / XP95
POM plastic
-20 °C to +60 °C
(-4 °F to +140 °F)
0 to 95%
no condensation
526 g (1.2 lbs)
135 x 161 x 61 mm (WxHxD)
5.3 x 6.3 x 2.4 inch (WxHxD)
Mounting hardware
1 door key
2 cable glands M20 x 1.5
1 blanking plug
Connection / mounting
Connection cable
2-lead
Recommended cable, standard
747180
J-Y(ST)Y-2x2x0.8 mm
Recommended cable for circuit integrity
907940
JE-H(ST)H E30 2x2x0.8 mm
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Electrostatic shielding
Not required
Note
Strong magnetic ¿elds are to be avoided in the vicinity of the
detectors.
Excerpt from label texts
Drucktext
Sprache
FEUERALARM
FEUERWEHR
deutsch
deutsch
Deutsche
Übersetzung
Feueralarm
Feuerwehr
FIRE ALARM
englisch
Feueralarm
ALARMA DE INCENDIO
spanisch
Feueralarm
ALARME INCENDIE
ALARME FEU
französisch
französisch
(Brand-) Feueralarm
Feueralarm
ALLARME ANTINCENDIO
italienisch
Feueralarm
HANDMELDER
holländisch
Handmelder
Feueralarm
POĩAR
polnisch
POŽIARNY POPLACH
slowakisch
Feueralarm
ϖϳήΤϟ΍ έ΍άϧ·
arabisch
Feueralarm
FIRE ALARM
engl./arab.
Feueralarm
slowak./engl.
Feueralarm
ϖϳήΤϟ΍ έ΍άϧ·
POŽIARNY POPLACH
FIRE ALARM
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 4 - 23
Product Sheet | Detecon
Manual call points
DMX outdoor application, addressable
DMX3195-I, yellow
Order no.: 910553
Technical specifications
In case of order the arbitrary/variable label text it is to be
indicated under „Information for production“ (see excerpt from
label texts).
Function
Type B, Latching Contact
Colour
similar to RAL 1021, yellow
Otherwise like Order no.: 910815
P31. 310.320en / 01.14
Excerpt from label texts
Drucktext
Sprache
HANDAUSLÖSUNG
HANDAUSLÖSUNG - Löschanlage
LÖSCHANLAGE
deutsch
deutsch
deutsch
Deutsche /engl.
Übersetzung
Handauslösung
Handauslösung - Löschanlage
Löschanlage
MANUAL RELEASE
CO2 RELEASE
CO2 MANUAL RELEASE
WATER RELEASE
GAS RELEASE
DELUGE MANUAL RELEASE
englisch
englisch
englisch
englisch
englisch
englisch
Handauslösung
CO2-Auslösung
CO2 Handauslösung
Wasserauslösung
Gasauslösung
Sprühflut Handauslösung
DISPARO MANUAL
spanisch
Handauslösung
COMMANDE MANUELLE
DECLENCHEMENT MANUEL
DECLENCHEMENT CO2
französisch
französisch
französisch
Handauslösung
Handauslösung
CO2 Auslösung
RILASCIO MANUALE
italienisch
Handauslösung
BLUSSING
HAND ACTIVERING
MANUELE BEDIENING
BEDIENING BLUSINSTALLATIE
SPROEIVLOED
holländisch
holländisch
holländisch
holländisch
holländisch
Löschung
Manuelle Löschung
Manuelle Bedienung
Bedienung Löschen
Löschmittel Zufuhr
DECLANúARE MANUALă
rumänisch
Handauslösung
RUþNÉ SPUSTENIE
CO2 RUþNÉ SPUSTENIE
RUþNÉ SPUSTENIE DELUZNE
slowakisch
slowakisch
slowakisch
Handauslösung
CO2 Handauslösung
Sprühflut Handauslösung
ϱϭΪϳ ϕϼσ·
arabisch
Handauslösung
ϩΎϴϤϟ΍ ϕϼσ·
ίΎϐϟ΍ ϕϼσ·
ϩϮϏήϟ΍ ϕϼσ·
arabisch
Wasserauslösung
arabisch
Gasauslösung
arabisch
Schaumauslösung
ϩϮϏήϟ΍ ϕϼσ· ΐϗ΍ήϣ
arabisch
Foam Monitor Release
ϩϮϏήϟ΍ ϦϘΣ
arabisch
Foam Injection
ϩϮϏήϟ΍ ΰΟΎΣ
arabisch
Foam Dyke
MANUAL RELEASE
engl./arab.
Handauslösung
CO2 RUþNÉ SPUSTENIE
CO2 MANUAL RELEASE
slowak./engl.
CO2-Handauslösung
RUþNÉ SPUSTENIE DELUZNE
DELUGE MANUAL RELEASE
slowak./engl.
Sprühflut Handauslösung
Drucktext
Sprache
WATER RELEASE
engl./arab.
Deutsche /engl.
Übersetzung
Wasserauslösung
engl./arab.
Gasauslösung
engl./arab.
Schaumauslösung
engl./arab.
Foam Monitor Release
engl./arab.
Foam Injection
engl./arab.
Foam Dyke
MANUAL RELEASE
PɎɒɈOɄ ɊɎCɅ
engl./russ.
Handauslösung
CO2 RUþNÉ SPUSTENIE
CO2 MANUAL RELEASE
slowak./engl.
CO2-Handauslösung
RUþNÉ SPUSTENIE DELUZNE
DELUGE MANUAL RELEASE
slowak./engl.
Sprühflut Handauslösung
ϩΎϴϤϟ΍ ϕϼσ·
GAS RELEASE
ίΎϐϟ΍ ϕϼσ·
FOAM RELEASE
ϩϮϏήϟ΍ ϕϼσ·
FOAM MONITOR RELEASE
ϩϮϏήϟ΍ ϕϼσ· ΐϗ΍ήϣ
FOAM INJECTION
ϩϮϏήϟ΍ ϦϘΣ
FOAM DYKE
ϩϮϏήϟ΍ ΰΟΎΣ
Approvals / marking
ϱϭΪϳ ϕϼσ·
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 4 - 24
Product Sheet | Detecon
Manual call points
DMX outdoor application, addressable
DMX3195-I, green
Order no.: 910824
Technical specifications
In case of order the arbitrary/variable label text it is to be
indicated under „Information for production“ (see excerpt from
label texts).
Otherwise like Order no.: 910815
Function
Type B, Non-Latching Contact
Colour
similar to RAL 6002, green
DMX3195-I, blue
Function
Type B, Non-Latching Contact
Colour
similar to RAL 5015, blue
Drucktext
Sprache
AVARINIS STABDYMAS
Gesinimo dujomis sistema
litauisch
STOP - AVƗRIJAS IZSLƝGŠANA
Dzƞšanas sistƞma ar gƘzi
lettisch
HÄTÄPYSÄYTYS –
Kaasusammutuslaitteistot
finnisch
Deutsche / engl.
Übersetzung
EMERGENCY STOP
Gas extinguishing system
2nd RELEASE
2nd EXT. RELEASE
englisch
englisch
2-te Auslösung
2-te Löschauslösung
STINGERE SUPLIMENTARĂ
rumänisch
Nachlöschen
CO2 DOHASENIE
DOHASENIE
slowakisch
slowakisch
CO2 Nachlöschen
Nachlöschen
DOHASENIE
SECOND DISCHARGE
slowak./engl.
Nachlöschen
STOPP-TASTER - Gaslöschanlage
EMERGENCY STOP
Gas extinguishing system
EXTINGUISHING DELAY
englisch
STOPP-TASTER - Gaslöschanlage
STOPP-TASTER - Gaslöschanlage
englisch
Löschverzug
PARO DE EMERGENCIA –
Sistema de extinction por gas
RETARDO DE DESCARGA
spanisch
STOPP-TASTER - Gaslöschanlage
spanisch
Löschverzug
ARRET D'URGENCE –
Système d'extinction à gaz
RETARDEMENT D'EXTINCTION GAZ
französisch
STOPP-TASTER - Gaslöschanlage
französisch
Löschverzug
ARRESTO DI EMERGENZA –
Impianto di estinzione a gas
ARRESTO CO2
italienisch
STOPP-TASTER - Gaslöschanlage
italienisch
CO2-Stopp
NOODSTOP –
Blusgas installatie
UITSTEL BLUSSING
holländisch
STOPP-TASTER - Gaslöschanlage
holländisch
Löschung aus
griechisch
STOPP-TASTER - Gaslöschanlage
russisch
CO2-Stopp
arabisch
Löschverzug
Löschverzug
˯ΎϔσϹ΍ ήϴΧ΄Η
bulgarisch
Excerpt from label texts
Deutsche / engl.
Übersetzung
Löschverzug
Hausalarm
STOPP-TASTER - Gaslöschanlage
Handbrandmelder
ǼIAKOȇTHȉ EKTAKTHȉ ANAĬKHȉ –
engl./arab.
In case of order the arbitrary/variable label text it is to be
indicated under „Information for production“ (see excerpt from
label texts).
Otherwise like Order no.: 910815
deutsch
deutsch
deutsch
deutsch
ȉȤIJijșȞį ȜįijįIJȖıIJșȣ Ȟı įıȢțȡ
P31. 310.320en / 01.14
Deutsche
Übersetzung
Nachlöschen
NACHFLUTEN - Gaslöschanlage
2-te Auslösung
2-te Löschauslösung
Sprache
STOPP-TASTER - Gaslöschanlage
ȻȽȻɋɃɄɈɉ ɌɊɃɋȻɈɀ
Ƀɨɬɭɛɦɛɱɣɺ ɸɛ ɞɛɬɠɨɠ ɬ ɞɛɢɩɩɜɫɛɸɨɩ
ɝɠɴɠɬɭɝɩ
deutsch
deutsch
deutsch
deutsch
Drucktext
schwedisch
EXTINGUISHING DELAY
Sprache
LÖSCHVERZUG
HAUSALARM
STOPP-TASTER Gaslöschanlage
HANDBRANDMELDER
NÖDSTOPP –
Gassläcksystem
˯ΎϔσϹ΍ ήϴΧ΄Η
Drucktext
NACHLÖSCHEN
NACHFLUTEN - Gaslöschanlage
2-te AUSLÖSUNG
2-te LÖSCHAUSLÖSUNG
Order no.: 910554
Technical specifications
CO2 CTOɊ
Excerpt from label texts
STOPP-TASTER - Gaslöschanlage
Approvals / marking
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 4 - 25
Product Sheet | Detecon
Manual call points
DMX outdoor application, addressable
DMX3195-I, variabel
Order no.: 910725
Technical specifications
Analog addressable manual call point for outdoor areas similar to EN 54-11 or EN 12094-3.
Free selection of the detector configuration possible
(Latching or non-latching contact, silicone free, special
labeling).
Applicable for operation in ¿re panels with Loop AP protocol. Addressing via DIP switches. The address can also be
modi¿ed after installation. The order is placed along with an
additional note on the detector, with order number and the
desired modi¿cations. Production is then performed with
manual machining by the process engineering department at
the lead plant in Bad Oldesloe. In addition to process engineering, a contract review is performed in order to comply
with regulations.
The description and connection instructions are attached to
the detector.
Function
Technology / protocol
Integrated
short circuit isolator
Rated voltage
Type B,
Latching or Non-Latching contact
Loop AP / XP95
yes
9V
Operating voltage
17 V - 28 V DC
Operating current
200 mA
Initial current max.
1 mA
IP rating (EN 60529)
IP 66
Enclosure material
Colour
Trigger mechanism material
Operating temperature
Relative humidity
(IEC721-3-3)
Speci¿cation similar to
Weight
Dimensions
Approvals / marking
PC
RAL 3001, red
RAL 1021, yellow
RAL 5015, blue
RAL 6002, green
POM plastic
-20 °C to +60 °C
(-4 °F to +140 °F)
0 to 95%
no condensation
EN 54-11
EN 12094-3
ca. 525 g (1.16 lbs)
135 x 161 x 61 mm (WxHxD)
5.3 x 6.3 x 2.4 inch (WxHxD)
Included in delivery
Mounting hardware
1 door key
2 cable glands M20 x 1.5
1 blanking plug
Connection / mounting
Connection cable
2-lead
Recommended cable, standard
747180
J-Y(ST)Y-2x2x0.8 mm
Recommended cable for circuit integrity
907940
JE-H(ST)H E30 2x2x0.8 mm
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Electrostatic shielding
Not required
P31. 310.320en / 01.14
Note
Strong magnetic ¿elds are to be avoided in the vicinity of the
detectors.
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 4 - 26
Product Sheet | Detecon
Manual call points
DMX outdoor application, addressable
KAX DIS 951r WP Manual Call Point, red
Order no.: 912580
Analog addressable manual call point outdoor areas with
integreated isolator, in accordance with EN 54-11.
Applicable for operation in ¿re alarm panels with Loop AP
protocol.
Addressing via DIP switches; the address can also be
modi¿ed after installation.
Markings or labels which do not comply with the standard will
void the EN 54-11 approval.
Operating instructions and address information are included
with the detector.
Included in delivery
1 key to reset / open the MCP
Technical specifications
Function
Not included in delivery
Type A, Latching Contact
Technology / protocol
Integrated
short circuit isolator
No. of detectors per loop for
mixed automatic and manual
Operating voltage
Operating current
Alarm current
Alarm indication
IP rating (EN 60529)
Enclosure material
Colour
Operating temperature
Relative humidity
(IEC721-3-3)
Speci¿cation according to
Weight
Dimensions
Mounting hardware
Loop AP / Discovery
yes
max. 126 pieces
17 V - 28 V DC
100 ȝA
4 mA
1 LED, red
Connection / mounting
Connection cable
2-lead
Recommended cable, standard
747180
J-Y(ST)Y-2x2x0.8 mm
Recommended cable for circuit integrity
907940
JE-H(ST)H E30 2x2x0.8 mm
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Electrostatic shielding
Not required
IP 67
PC / ABS
red
-30 °C to + 70 °C
(-22 °F to +158 °F)
0 to 95%
no condensation
EN 54-11
approx. 180 g (6.6 lbs)
110 x 110 x 74 mm (WxHxD)
4.3 x 4.3 x 2.9 inch (WxHxD)
Approvals / marking
P31. 310.320en / 01.14
0359-CPD-0186
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 4 - 27
Product Sheet | Detecon
Manual call points
DMX outdoor application, conventional
DMX3100 Manual Call Point, red
Order no.: 906939
Conventional manual call point for outdoor areas in
accordance with EN 54-11.
Applicable for operation on conventional lines of the ¿re
alarm panels FMZ 4100 and FMZ 5000.
The white inside sign can be replaced with other labels (see
DMX outdoor application, accessories).
Markings or labels which do not comply with the standard will
void the VdS and EN 54-11 approvals.
Included in delivery
Technical specifications
Function
Type B, Latching Contact
Technology
Conventional
Rated voltage
9V
Operating voltage
7.6 V - 13.2 V DC
Quiescent current
5 mA (at 9 V)
Alarm current
20 mA (at 9 V)
IP rating (EN 60529)
IP 66
Enclosure material
PC
Colour
RAL 3001, red
Trigger mechanism material
Operating temperature
Relative humidity
(IEC721-3-3)
Speci¿cation according to
Weight
Dimensions
POM plastic
- 35 °C to +60 °C
(-31 °F to +140 °F)
0 to 95%
no condensation
EN 54-11
475 g (1.1 lbs)
135 x 161 x 61 mm (WxHxD)
5.3 x 6.3 x 2.4 inch (WxHxD)
Mounting hardware
1 door key
2 cable glands M20 x 1.5
1 blanking plug
Connection / mounting
Connection cable
2-lead
Recommended cable, standard
747180
J-Y(ST)Y-2x2x0.8 mm
Recommended cable for circuit integrity
907940
JE-H(ST)H E30 2x2x0.8 mm
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Electrostatic shielding
Not required
Notes
Strong magnetic ¿elds should be avoided in the vicinity of the
detectors.
Approvals / marking
0786-CPD-20688
P31.310.310en / 01.14
G 209029
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 4 - 28
Product Sheet | Detecon
Manual call points
DMX outdoor application, conventional
DMX3100 Manual Release, yellow
Order no.: 906940
Technical specifications
Approvals / marking
Function
Type B, Latching Contact
Colour
RAL 1021, yellow
Speci¿cation according to
EN 12094-3
G 209030
0786-CPD-20689
Otherwise like Order no. 906939
Markings or labels which do not comply with the standard will
void the VdS and EN 12094-3 approvals.
Notes
This MCP uses German labelling. For other languages
please use the Order no. 909032
DMX3100 Emergency Button, blue
Order no.: 907021
Technical specifications
Approvals / marking
Type B,
Non-Latching Contact
RAL 5015, blue
Function
Colour
Speci¿cation according to
EN 12094-3
G 209031
0786-CPD-20690
Otherwise like Order no. 906939
Markings or labels which do not comply with the standard will
void the VdS and EN 12094-3 approvals.
Notes
This MCP uses German labelling. For other languages
please use the Order no. 909032
DMX3100 2nd Release, green
Order no.: 907022
Technical specifications
The outside sign is as speci¿ed by VdS 2496 Issue 12.96.
Type B,
Non-Latching Contact
RAL 6002, green
Function
Colour
P31.310.310en / 01.14
Speci¿cation similar to
EN 12094-3
Approvals / marking
G 209031
Otherwise like Order no. 906939
Markings or labels which do not comply with the standard will
void the VdS approval.
Notes
This MCP uses German labelling. For other languages
please use the Order no. 909032
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 4 - 29
Product Sheet | Detecon
Manual call points
DMX outdoor application, conventional
DMX3100 2GRU Manual Release, yellow
Order no.: 907024
Conventional manual call point for outdoor areas in
accordance with EN 12094-3.
Applicable for operation on conventional lines of the ¿re
alarm panels FMZ 4100 and FMZ 5000.
The outside sign and the white inside sign can be replaced
with other labels (see DMX outdoor application, accessories).
Markings or labels which do not comply with the standard will
void the VdS and EN 12094-3 approvals.
The DMX3100 2GRU is designed for 2-line/zone coincidence.
Two alarm lines are activated if the trigger button is pressed.
Included in delivery
Technical specifications
Function
Type B, Latching Contact
Technology
Conventional
Rated voltage
9V
Operating voltage
7.6 V - 13.2 V DC
Quiescent current
5 mA (at 9 V)
Alarm current
20 mA (at 9 V)
IP rating (EN 60529)
IP 66
Enclosure material
PC
Colour
Mounting hardware
1 door key
2 cable glands M20 x 1.5
1 blanking plug
Connection / mounting
Connection cable
2-lead
Recommended cable, standard
747180
J-Y(ST)Y-2x2x0.8 mm
Recommended cable for circuit integrity
907940
JE-H(ST)H E30 2x2x0.8 mm
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Electrostatic shielding
Not required
RAL 1021, yellow
Trigger mechanism material
Operating temperature
Relative humidity
(IEC721-3-3)
Speci¿cation according to
POM plastic
-35 °C to +60 °C
(-31 °F to +140 °F)
0 to 95%
no condensation
EN 12094-3
2GRU
2 microswitches for 2 zones
Weight
475 g (1.1 lbs)
135 x 161 x 61 mm (WxHxD)
5.3 x 6.3 x 2.4 inch (WxHxD)
Dimensions
Notes
Strong magnetic ¿elds should be avoided in the vicinity of the
detectors.
This MCP uses German labelling. For other languages
please use the order no. 909032
Approvals / marking
0786-CPD-20689
P31.310.310en / 01.14
G 209030
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 4 - 28
Product Sheet | Detecon
Manual call points
DMX outdoor application, conventional
DMX3100 Manual Call Point, variable
Order no.: 909032
Technical specifications
Conventional manual call point for outdoor areas similar to
EN 54-11 and EN 12094-3.
Free selection of the detector configuration possible
(Latching or non-latching contact, silicone free, special
labeling).
The order is placed along with an additional note on the
detector, with order number and the desired modi¿cations.
Production is then performed with manual machining by the
process engineering department at the lead plant in Bad
Oldesloe. In addition to process engineering, a contract
review is performed in order to comply with regulations.
Operating instructions and connection notes are included
with the detector.
Function
Technology
Rated voltage
Operating voltage
Quiescent current
Alarm current
IP rating (EN 60529)
Enclosure material
Colour
Trigger mechanism material
Operating temperature
Relative humidity
(IEC721-3-3)
Speci¿cation similar to:
Weight
Dimensions
Approvals / marking
Type B,
Latching or Non-Latching contact
Conventional
9V
7.6 V - 13.2 V DC
5 mA (at 9 V)
20 mA (at 9 V)
IP 66
PC
RAL 3001, red
RAL 1021, yellow
RAL 5015, blue
RAL 6002, green
POM plastic
-35 °C to +60 °C
(-31 °F to +140 °F)
0 to 95%
no condensation
EN 54-11
EN 12094-3
approx. 475 g (1.1 lbs)
135 x 161 x 61 mm (WxHxD)
5.3 x 6.3 x 2.4 inch (WxHxD)
Included in delivery
Mounting hardware
1 door key
2 cable glands M20 x 1.5
1 blanking plug
Connection / mounting
Connection cable
2-lead
Recommended cable, standard
747180
J-Y(ST)Y-2x2x0.8 mm
Recommended cable for circuit integrity
907940
JE-H(ST)H E30 2x2x0.8 mm
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Electrostatic shielding
Not required
Notes
P31.310.310en / 01.14
Strong magnetic ¿elds should be avoided in the vicinity of the
detectors.
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 4 - 29
Product Sheet | Detecon
Manual call points
DMX outdoor application, addressable, Ex
KAX95 Ex Manual Call Point, red
Order no.: 901321
Analog addressable manual call point for outdoor use in Ex
zone 0 and 20.
Provided for use on ¿re alarm control units with Loop AP
protocol.
Addressing via DIP switch, the address can also be modi¿ed
after installation.
Detector with intrinsically safe electronics for operation in
areas with a risk of explosion.
Connection only via an Ex Loop AP 24 V Ex security barrier.
Markings or labels which do not comply with the standard will
void the EN 54-11 approval.
Included in delivery
Technical specifications
Function
1 key to reset / open the MCP
Type A, Latching Contact
Technology / protocol
Integrated
short circuit isolator
Operating voltage
Operating current
Alarm display
IP rating (EN 60529)
Enclosure material
Colour
Loop AP / XP95
no
14 V - 22 V DC
Connection cable
Conductor cross-section
Electrostatic shielding
2-lead
max. 2.5 mm2 (0.004 square inch)
Not required
300 ȝA
1 LED, red
IP 67
Polycarbonate /ABS
red
Operating temperature, T4
-20 °C to +60 °C (-4 °F to +140 °F)
Operating temperature, T5
Relative humidity
(IEC721-3-3)
Weight
-20 °C to +45 °C (-4 °F to +113 °F)
0 to 95%
no condensation
ca. 240 g (0.53 lbs)
97.5 x 93 x 71 mm (WxHxD)
3.8 x 3.7 x 2.8 inch (WxHxD)
Dimensions
Connection / mounting
Notes
Analogue addressable detectors for explosive areas are to
be used in the Loop AP branch. For this purpose the protocol
interface is to be used
Connection diagram
Approvals / marking
Ex conformity in acc. with 94/9/EG
x II 1G Ex ia IIC T5 Ga (-20°C ” Ta ” +45°C)
x II 1G Ex ia IIC T4 Ga (-20°C ” Ta ” +60°C)
x II 1D Ex ia IIIC T135°C Da (-20°C ” Ta ” +60°C)
Examination certi¿cate:
BAS 02 ATEX 1290
P31.310.330 - 1en / 01.14
0786-CPD-0812
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 4 - 30
Product Sheet | Detecon
Manual call points
DMX outdoor application, addressable, Ex
KAX95 Ex Manual Call Point, yellow
Order no.: 912581
Analog addressable manual call point for outdoor use in Ex
zone 0 and 20.
Provided for use on ¿re alarm control units with Loop AP
protocol.
Addressing via DIP switch, the address can also be modi¿ed
after installation.
Detector with intrinsically safe electronics for operation in
areas with a risk of explosion.
Connection only via an Ex Loop AP 24 V Ex security barrier.
Included in delivery
Technical specifications
Function
Type A, Latching Contact
Technology / protocol
Integrated
short circuit isolator
Operating voltage
Operating current
Alarm display
IP rating (EN 60529)
Enclosure material
Colour
Loop AP / XP95
no
14 V - 22 V DC
300 ȝA
1 LED, red
IP 67
Polycarbonate /ABS
yellow
Operating temperature, T4
-20 °C to +60 °C (-4 °F to +140 °F)
Operating temperature, T5
Relative humidity
(IEC721-3-3)
Weight
-20 °C to +45 °C (-4 °F to +113 °F)
0 to 95%
no condensation
ca. 240 g (0.53 lbs)
97.5 x 93 x 71 mm (WxHxD)
3.8 x 3.7 x 2.8 inch (WxHxD)
Dimensions
1 key to reset / open the MCP
Connection / mounting
Connection cable
Conductor cross-section
Electrostatic shielding
2-lead
max. 2.5 mm2 (0.004 square inch)
Not required
Notes
Analogue addressable detectors for explosive areas are to
be used in the Loop AP branch. For this purpose the protocol
interface is to be used
Connection diagram
Approvals / marking
P31.310.330 - 1en / 01.14
Ex conformity in acc. with 94/9/EG
x II 1G Ex ia IIC T5 Ga (-20°C ” Ta ” +45°C)
x II 1G Ex ia IIC T4 Ga (-20°C ” Ta ” +60°C)
x II 1D Ex ia IIIC T135°C Da (-20°C ” Ta ” +60°C)
Examination certi¿cate:
BAS 02 ATEX 1290
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 4 - 31
Product Sheet | Detecon
Manual call points
DMX outdoor application, conventional, Ex
dC 31 Manual Call Point, red
Order no.: 908711
Conventional manual call point for outdoor areas in Ex zone
1 and 21 in accordance with EN 54-11.
Designed for operation on conventional lines of the ¿re alarm
panels FMZ 4100 and FMZ 5000.
The white inside sign can be replaced with other labels (see
DMX outdoor application, accessories).
Markings or labels which do not comply with the standard will
void the VdS and EN 54-11 approvals.
Included in delivery
Technical specifications
Function
Type B, Latching Contact
Technology
Mounting hardware
1 door key
2 cable glands M20 x 1.5
1 blanking plug
Conventional
Rated voltage
9V
Operating voltage
7.6 V - 9.7 V DC
Quiescent current
5 mA (at 9 V)
Alarm current
20 mA (at 9 V)
IP rating (EN 60529)
IP 66
Enclosure material
PC
Colour
RAL 3001, red
Trigger mechanism material
POM plastic
-20 °C to +60 °C
(-4 °F to +140 °F)
-35 °C to +60 °C
(-31 °F to +140 °F)
0 to 95%
no condensation
EN 54-11
Operating temperature
Storage temperature
Relative humidity
(IEC721-3-3)
Speci¿cation according to
Ex zones
Connection / mounting
Connection cable
2-lead
Recommended cable, standard
747180
J-Y(ST)Y-2x2x0.8 mm
Recommended cable for circuit integrity
907940
JE-H(ST)H E30 2x2x0.8 mm
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Electrostatic shielding
Not required
Notes
An Ex barrier and the blue ¿re alarm cable are not required.
Strong magnetic ¿elds should be avoided in the vicinity of the
detectors.
1 (Gas) and 21 (Dust)
Weight
475 g (1.1 lbs)
135 x 161 x 61 mm (WxHxD)
5.3 x 6.3 x 2.4 inch (WxHxD)
Dimensions
Approvals / marking
Ex conformity in acc. with 94/9/EC
x II 2G Ex emb IIC T6 Gb
x II 2D Ex tb IIIC T80°C Db
Examination certi¿cate:
0786-CPD-20309
P31.310.330 - 2en / 01.14
G 206113
BVS 09 ATEX E016 X
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 4 - 32
Product Sheet | Detecon
Manual call points
DMX outdoor application, conventional, Ex
dC31 Manual Release, yellow
Order no.: 908712
Approvals / marking
Technical specifications
Function
Type B, Latching Contact
Colour
Ex conformity in acc. with 94/9/EC
x II 2G Ex emb IIC T6 Gb
x II 2D Ex tb IIIC T80°C Db
RAL 1021, yellow
Speci¿cation according to
EN 12094-3
Examination certi¿cate:
BVS 09 ATEX E016 X
G 207079
0786-CPD-20310
Otherwise like Order no. 908711
Markings or labels which do not comply with the standard will
void the VdS and EN 12094-3 approvals.
Notes
Please select the label text of the MCP when ordering.
dC31 Emergency Button, blue
Order no.: 908713
Technical specifications
Approvals / marking
Function
Type B, Non-Latching Contact
Colour
Ex conformity in acc. with 94/9/EC
x II 2G Ex emb IIC T6 Gb
x II 2D Ex tb IIIC T80°C Db
RAL 5015, blue
Speci¿cation according to
EN 12094-3
Examination certi¿cate:
BVS 09 ATEX E016 X
G 207099
0786-CPD-20311
Otherwise like Order no. 908711
Markings or labels which do not comply with the standard will
void the VdS and EN 12094-3 approvals.
Please select the label text of the MCP when ordering.
dC31 2nd Release, green
Order no.: 908714
Technical specifications
The outside sign is as speci¿ed by VdS 2496 Issue 12.96.
Function
Type B, Non-Latching Contact
Colour
RAL 6002, green
Speci¿cation similar to
P31.310.330 - 2en / 01.14
Notes
EN 12094-3
Approvals / marking
Ex conformity in acc. with 94/9/EC
x II 2G Ex emb IIC T6 Gb
x II 2D Ex tb IIIC T80°C Db
Examination certi¿cate:
Otherwise like Order no. 908711
Markings or labels which do not comply with the standard will
void the VdS approval.
BVS 09 ATEX E016 X
G 207099
Notes
Please select the label text of the MCP when ordering.
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 4 - 33
Product Sheet | Detecon
Manual call points
DMX outdoor application, accessories
Order no.: 907890
DMX3100 SUX95 card, button
Order no.: 907912
DMX3100 card, switch
Order no.: 907883
DMX3100 card, button
Order no.: 907884
DMX3100 card, 2GRU, switch
Order no.: 907887
DMX3100 card, ZPD, switch
Order no.: 907886
DMX3100 SUX50 card, switch
Order no.: 907889
Special labelling for white inside panel,
complete
Order no.: 907192
P31.310.340en / 02.13
DMX3100 SUX95 card, switch
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 4 - 34
Product Sheet | Detecon
Manual call points
DMX accessories, general
Order no.: 173881
Replacement glass pane, clear
Order no.: 903563
P31.310.940en / 02.13
"D" shape door key
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 4 - 35
Product Sheet | Detecon
Standard detectors
General information
Loop detectors and modules
The detector series offers ionisation smoke detectors, optical
smoke detectors, heat detectors and a multisensor detector,
communicating with the FMZ 5000 with a Loop AP module.
The series is supplemented by manual call points, modules,
isolators and other loop nodes.
Every product responds to queries and control commands
from the ¿re alarm panels. It communicates with the ¿re
alarm panel about the status, type and position as well as
external commands and other information contributing to the
alarm status. The signals are also checked for errors.
A some detectors ¿ve different operating modes are
available which can be selected via the ¿re alarm panel.
Each operating mode has speci¿c response behaviour which
corresponds to the ¿re criteria to be expected.
Conventional detectors
Conventional detectors with a wide range of supply voltages.
The interactive loop detectors de¿ne a new standard in reliable ¿re detection. Highly developed software algorithms and
strongly expanded functionalities set new standards. Fire characteristics are selected in such a way that a ¿re will be safely
detected.
The various options for the individual adjustment of the detector sensitivity and several setup modes dependent on the time of
day guarantee the optimum detector adjustment to the area being monitored.
With these performance characteristics all safety concepts can be implemented and ensure maximum customer bene¿t:
- Five detector sensitivity stages/algorithms for each application (for the standard loop detectors)
- Detector sensitivity that can be switched according to environmental conditions depending on the time of day (for the standard
loop detectors)
- Automatic drift compensation of the measuring system for constant sensitivity over the whole period of application
- Automatic contamination detection and early maintenance indication for the ef¿cient deployment of maintenance personnel
- Automatic function monitoring including sensor technology for greatest availability
- Safe operation due to emergency running characteristics during a potential processor failure
- Non-volatile memory, e.g. date of commissioning, last service, reference number, value of the drift compensation
P31.311.000en / 01.14
A variety of detector installation bases and numerous modules for adding contacts and issuing signals complete this system.
Visual and acoustic signal transmitters can also be switched directly on the loop to issue alarms.
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 5 - 1
Product Sheet | Detecon
Standard detectors
Optical smoke detectors, addressable
Optical smoke detector OMX95
Order no.: 907541
Analog addressable optical smoke detector. Designed for
use in areas where only low false alarm sources can be
expected.
Applicable for operation in ¿re alarm panels FMZ 5000 with
Loop AP protocol.
5 sensitivity modes, adjustable via software control.
Addressing via separate address card. The address can also
be changed after installation.
Not included in delivery
Product features
•
•
•
Detector base
Address card
Constant function monitoring of the sensors, software
and hardware including the microcontroller.
Non-volatile memory for detector data.
Day/night switching via ¿re alarm panel with different
sensitivities.
Connection / mounting
Connection cable
2-lead
Recommended cable, standard
747180
J-Y(ST)Y-2x2x0.8 mm
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Electrostatic shielding
not required
Technical specifications
Detection method
Infrared photo diode
Technology / protocol
Loop AP / Discovery
Integrated isolator
no
Operating voltage
17 V - 28 V DC
Quiescent current
0.65 mA
Alarm current
3.4 mA
Alarm indication
Operating temperature
2 red LEDs
Weight
Dimensions
Sensitivity modes
smoke
tmin alarm
1
1.4 % / m (39.4 inch)
5s
2
1.4 % / m (39.4 inch)
30 s
3
2.1 % / m (39.4 inch)
5s
4
2.1 % / m (39.4 inch)
30 s
5
2.8 % / m (39.4 inch)
5s
-20 °C to +60 °C (-4 °F to 140 °F)
IP rating (EN 60529)
Enclosure material
Relative humidity
(IEC721-3-3)
Speci¿cation according to
see accessories
901297
IP 43
White polycarbonate
0 to 95%
no condensation
EN 54 Part 7
Notes
The response sensitivity must be adjusted to the environmental
conditions. The settings can be changed at any time.
105 g (0.2 lbs)
100 x 42 mm (dia. x H)
3.9 x 1.7 inch (dia.xH)
Approvals / marking
0832-CPD-0024
P31.311.120en / 01.14
G 208033
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 5 - 2
Product Sheet | Detecon
Standard detectors
Ionisation smoke detectors, addressable
Ionisation smoke detector IMX95
Order no.: 907544
Analog addressable ionisation smoke detector. Designed for
use in areas where occasional dust can be expected.
Applicable for operation in ¿re alarm panels FMZ 5000 with
Loop AP protocol.
5 sensitivity modes, adjustable via software control.
Addressing via separate address card. The address can also
be changed after installation.
Product features
Not included in delivery
•
Constant function monitoring of the sensors, software
and hardware including the microcontroller.
•
Non-volatile memory for detector data.
•
Day/night switching via ¿re alarm panel with different
sensitivities.
Detector base
Address card
Connection / mounting
Technical specifications
Detection method
Technology / protocol
Ionisation chamber
no
Radioactive isotope
Operating voltage
1
y = 0.45
5s
Max. 10 m/s (394 inch)
equivalent to 600 m (0.37 miles)
above MSL max.
17 V - 28 V DC
2
y = 0.45
30 s
3
y = 0.70
5s
4
y = 0.70
30 s
5
y = 1.00
5s
0.5 mA
Alarm current
3.5 mA
Alarm indication
2 red LEDs
-20 °C to +60 °C (-4°F to +140 °F)
IP rating (EN 60529)
Enclosure material
Relative humidity
(IEC721-3-3)
Speci¿cation according to
Weight
P31.311.160en / 01.14
Dimensions
tmin alarm
33.3 kBq
Quiescent current
Operating temperature
Sensitivity modes
Americium 241
Radioactivity
Atmospheric pressure
Connection cable
2-lead
Recommended cable, standard
747180
J-Y(ST)Y-2x2x0.8 mm
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Electrostatic shielding
not required
Loop AP / Discovery
Integrated isolator
Air velocity
see accessories
901297
IP 43
White polycarbonate
0 to 95%
no condensation
EN 54 Part 7
Note
The response sensitivity must be adjusted to the
environmental conditions. The settings can be changed at
any time.
The detector contains radioactive materials. The operating
instructions and current laws and relating to radiation
protection must be observed.
105 g (0.2 lbs)
100 x 42 mm (dia. x H)
3.9 x 1.7 inch (DxH)
Approvals / marking
G 208036
0832-CPD-0023
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 5 - 3
Product Sheet | Detecon
Standard detectors
Multisensor detectors, addressable
Multisensor detector OWMX95
Order no.: 907543
Analog addressable multisensor detector consisting of
a combination of an optical smoke detector and a heat
detector. Designed for use in areas where regular false alarm
sources can be expected.
Intended for operation in ¿re alarm panels FMZ 5000 with
Loop AP protocol.
5 sensitivity modes, adjustable via software control.
Addressing via separate address card. The address can also
be changed after installation.
Optional accessories
Product features
•
Constant function monitoring of the sensors, software
and hardware including the microcontroller.
Detector remote indicator MPX 070
•
Non-volatile memory for detector data.
Not included in delivery
•
Day/night switching via ¿re alarm panel with different
sensitivities.
Detector base
Address card
Heat detection method
Technology / protocol
Infrared photo diode
NTC temperature sensor
Loop AP / Discovery
Integrated isolator
no
Operating voltage
17 V - 28 V DC
Quiescent current
0.75 mA
Heat
Trigger type
tminAlarm
1
1.1 % / m
(39 inch)
high
Multisensor
20 s
2
2.1 % / m
(39 inch)
no trigger
Optical
30 s
White polycarbonate
0 to 95%
no condensation
EN 54 part 5 and 7
3
2.8 % / m
(39 inch)
low
Multisensor
20 s
4
4.2 % / m
(39 inch)
high
Multisensor
20 s
105 g (0.2 lbs)
100 x 50 mm (dia. x H)
3.9 x 2 inch (dia.xH)
5
no trigger
A1 class
A1
heat detector
30 s
2 red LEDs
-20 °C to +60 °C
(-4 °F to +140 °F)
IP 43
Operating temperature
IP rating (EN 60529)
Dimensions
Notes
P31.311.520en / 01.14
Approvals / marking
G 208034
Sensitivity modes
3.5 mA
Alarm indication
Weight
Connection cable
2-lead
Recommended cable, standard
747180
J-Y(ST)Y-2x2x0.8 mm
Conductor cross-section Max. 2.5 mm2 (0.004 square inch)
Electrostatic shielding
not required
Smoke
Alarm current
Enclosure material
Relative humidity
(IEC721-3-3)
Speci¿cation according to
see accessories
901297
Connection / mounting
Technical specifications
Smoke detection method
905568
0832-CPD-0025
The response sensitivity must be adjusted to the ambient
conditions. The settings can be changed at any time.
When using the detector in mode 5 the number of max.
permitted monitoring areas for heat detectors must not be
exceeded.
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 5 - 4
Product Sheet | Detecon
Standard detectors
Heat detectors, addressable
Heat detector WMX95
Order no.: 907542
Analog addressable rate-of-rise and maximum heat detector
for use in areas where interference variables like smoke can
be expected (e.g. of¿ce/storage areas, industrial plants or
test stands).
Applicable for operation in ¿re alarm panels FMZ 5000 with
Loop AP protocol.
3 response classes in accordance with EN54-5 and
2 temperature ranges adjustable via software control.
Addressing via separate address card. The address can also
be changed after installation.
Optional accessories
Product features
•
Constant function monitoring of the sensors, software
and hardware including the microcontroller.
Parallel indicator LMX5000
•
Non-volatile memory for detector data.
Not included in delivery
•
Day/night switching via ¿re alarm panel with different
sensitivities.
Detector base
Address card
Technology / protocol
NTC temperature sensor
Loop AP / Discovery
Integrated isolator
no
Response classes
A1R, A2, A2S
Temperature ranges
Connection cable
2-lead
Recommended cable, standard
747180
J-Y(ST)Y-2x2x0.8 mm
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Electrostatic shielding
not required
CR, CS
Sensitivity modes
Operating voltage
17 V - 28 V DC
Quiescent current
0.5 mA
Alarm current
3.4 mA
1
A1R
54 °C (129 °F) to 65 °C (149 °F)
2 red LEDs
+54 °C to +100 °C
(+129.2 °F to +212 °F)
-20 °C to +80 °C
(-4 °F to +176 °F)
IP 53
2
A2
54 °C (129 °F) to 70 °C (158 °F)
3
A2S
54 °C (129 °F) to 70 °C (158 °F)
4
CR
84 °C (129 °F) to 100 °C (212 °F)
5
CS
84 °C (129 °F) to 100 °C (212 °F)
Alarm indication
Response temperature
Operating temperature
IP rating (EN 60529)
Enclosure material
Relative humidity
(IEC721-3-3)
Speci¿cation according to
Weight
Dimensions
P31.311.220en / 01.14
see accessories
901297
Connection / mounting
Technical specifications
Detection method
908499
White polycarbonate
0 to 95%
no condensation
EN 54 Part 5
class
temperature
Notes
The response sensitivity must be adjusted to the environmental
conditions. The settings can be changed at any time.
105 g (0.2 lbs)
100 x 42 mm (dia. x H)
3.9 x 1.7 inch (DxH)
Approvals / marking
G 208035
0832-CPD-0022
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 5 - 5
Product Sheet | Detecon
Standard detectors
Detector accessories, addressable
Detector base BAX 210
Order no.: 901289
Base for all Loop AP detectors including address card with
large-size contact screws for all connections. Easy assembly
and simple insertion of the detectors by clockwise rotation
and catch. A connection for a detector remote indicator is
available.
Included in delivery
1 Detector base in standard design including address cards 1
to 126.
Not included in delivery
Mounting hardware
Technical specifications
Material
PC
Integrated isolator
no
IP rating (EN60529)
Colour
Ambient temperature
Weight
Dimensions
Approvals / marking
IP 43
White
-20 °C to +70 °C
(-4 °F to +158 °F)
55 g (0.1 lbs)
100 x 8 mm (dia. x H)
3.9 x 0.3 inch (dia. x H)
Detector base BAX 284 I
Order no.: 910790
Base for all Loop AP detectors including address card
with dual isolator and large-size contact screws for all
connections. For the separation of individual line sections in
the event of short circuits in loop operation. Easy assembly
and simple insertion of the detectors by clockwise rotation
and catch. A connection for a detector remote indicator is
available.
Included in delivery
1 Detector base in standard design including address cards 1
to 126.
Technical specifications
PC
Integrated isolator
yes
Fault indication
IP rating (EN60529)
Colour
P31.311.720en / 01.14
Not included in delivery
Material
Ambient temperature
Weight
Dimensions
Yellow LED
IP 43
White
-20 °C to +60 °C
(-4 °F to +140 °F)
100 g (0.2 lbs)
100 x 24 mm (dia. x H)
3.9 x 0.9 inch (dia. x H)
Mounting hardware
Approvals / marking
G 210033
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
0832-CPD-1011
Chapter 5 - 6
Product Sheet | Detecon
Standard detectors
Detector accessories, addressable
Isolator base BAX 211
Order no.: 901294
Base for the ISX 720 I isolator with large-size contact screws
for all connections. Easy assembly and simple insertion of
the isolator by clockwise rotation and lock.
Included in delivery
1 Isolator base in standard design.
Not included in delivery
Mounting hardware
Isolator ISX 720
901293
Technical specifications
Material
PC
IP rating (EN60529)
Colour
Ambient temperature
Weight
Dimensions
Approvals / marking
IP 43
White
-20 °C to +60 °C
(-4 °F to +140 °F)
55 g (0.2 lbs)
100 x 23 mm (dia. x H)
3.9 x 0.9 inch (dia. x H)
Isolator ISX 720 I
Order no.: 901293
Loop AP isolator for the separation of individual line sections
in the event of short circuits in loop operation. Easy assembly
and simple insertion of the isolator in the matching base by
means of clockwise rotation and lock.
Included in delivery
1 isolator for use in isolator base BAX 211.
Approvals / marking
G 200083
Technical specifications
Material
PC
Fault indication
IP rating (EN60529)
Colour
Ambient temperature
P31.311.720en / 01.14
0832-CPD-0843
Weight
Dimensions
Yellow LED
IP 43
White
-20 °C to +60 °C
(-4 °F to +140 °F)
75 g (0.2 lbs)
100 x 25 mm (dia. x H)
3.9 x 1 inch(dia. x H)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 5 - 7
Product Sheet | Detecon
Standard detectors
Detector accessories, addressable
Isolator ISX 284 R
Order no.: 914137
Loop AP isolator for the separation of individual line sections
in the event of short circuits in Loop operation. Easy assembly for mounting on a mounting rail.
Included in delivery
1 isolator for mounting on a mounting rail
Approvals / marking
Technical specifications
Fault indication
Yellow LED
- 20 °C to + 60 °C
(-4 °F to +140 °F)
20 g
Ambient temperatur
Weight
Dimensions
63 x 38.8 x 43 mm (BxHxT)
Bypass detector BMX1001 AP
Order no.: 908689
The BMX1001 bypass box for the accomodation of an analogue addressable optical smoke detector OMX95 to monitor
exhaust air and air conditioning ducts with higher air speeds.
Not included in delivery
Optical smoke detector OMX95
Loctite AVK 586, bottle 50 ml
Assembly tool for rivet nuts
907541
886226
Connection / mounting
Recommended cable
Technical specifications
Air Àow
Detector slot
Pipe for bypass detector
Enclosure material
Ambient temperature
IP rating
P31.311.720en / 01.14
Weight with 2 pipes
Dimensions
1 m (39 inch)/s to max.
20 m (787 inch)/s
1 Detector base BAX 284-I
2 threaded pipes DN15 galvanized,
540 mm
Aluminium diecast, grey
-20 °C to +60 °C
(-4 °F to +140 °F)
IP 23
3500 g (7.7 lbs)
130 x 165 x 95 mm (BxHxT)
5.1 x 6.5 x 3.7 inch (BxHxT)
J-Y (St) Y 2x2x0.8 mm, red
Note
VdS approval only for bypass box with optical smoke detector
OMX95.
Approval for the control of ¿re damper does not exist.
Approvals / marking
G 28406
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 5 - 8
Product Sheet | Detecon
Standard detectors
Detector accessories, addressable
Isolator XP95 IP65, complete
Order no.: 905702
Isolator for the separation of individual line sections during
short circuit in loop AP in robust design.
Easy assembly and simple insertion of the isolator with base
in the additional enclosure for industrial applications.
Included in delivery
1 Abox 100
1 mounting plate, complete
1 Isolator ISX 720
1 Isolator base BAX 211
Technical specifications
Material
905711
908422
901293
901294
PC
IP rating (EN60529)
Colour of lower enclosure section
Colour of upper enclosure section
Ambient temperature
Weight
Dimensions
IP 65
grey
red
-20 °C to +60 °C
(-4 °F to +140 °F)
340 g (0.8 lbs)
140 x 140 x 70 mm (WxHxD)
5.5 x 5.5 x 2.8 inch (WxHxD)
Addressing card ACX 771
Not included in delivery
Mounting hardware
Order no.: 901297
Address cards for detectors type XP and DIS, unlabelled,
100 pcs per packaging unit.
P31.311.720en / 01.14
Approvals / marking
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 5 - 9
Product Sheet | Detecon
Standard detectors
Optical smoke detectors, addressable, Ex
OMX95 Ex
Order no.: 901318
Analog addressable optical smoke detector for Ex zone 0
designed for use in hazard areas where only low false alarm
sources can be expected.
Provided for operation on ¿re alarm control panels FMZ 5000
with Loop AP protocol.
Addressing by means of separate address card. The address
can also be changed after installation.
Detector with intrinsically safe electronics for operation in
areas hazard.
Connection only via a safety barrier Ex Loop AP 24 V.
Product features
Not included in delivery
•
Constant function monitoring of the sensors, software
and hardware including the microcontroller.
•
Detector for use in zone 0.
Detector base
Address card
Safety barrier Ex Loop AP 24 V
Protokollinterface Loop AP
Technical specifications
Detection method
Technology / protocol
Connection / mounting
Infrared photo diode
Loop AP / XP95
Integrated isolator
no
Operating voltage
14 V - 22 V DC
Quiescent current
0.34 mA
Alarm current
Operating temperature, T4
Operating temperature, T5
IP rating (EN 60529)
3.4 mA
-20 °C to + 60 °C
(-4 °F to +140 °F)
-20 °C to +45 °C
(-4 °F to +113 °F)
IP 43
Enclosure material
Relative humidity
(IEC721-3-3)
Speci¿cation to
White polycarbonate
0 to 95%
no condensation
EN 54 part 7
Weight
105 g (0.2 lbs)
100 x 42 mm (DxH)
3.9 x 1.7 inch (DxH)
Dimensions
Connection cable
Recommended cable
J-Y(ST)Y-2x2x0.8 mm
Conductor cross-section
Electrostatic shielding
2-lead
747180
max. 2.5 mm2 (0.004 square inch)
not required
Note
Analog addressable detectors for hazard areas are to be
connected to the stub line of Loop AP. The protocol interface
and the safety barrier Ex Loop AP have to be used.
Approvals / marking
Ex conformity in acc. with 94/9/EG
x II 1G Ex ia IIC T5 Ga (-20°C ” Ta ” +45°C)
x II 1G Ex ia IIC T4 Ga (-20°C ” Ta ” +60°C)
P31.311.130-2en / 01.14
see accessories
901297
901324
901322
EC type approval certi¿cate:
BAS 02 ATEX 1289
Ex conformity Russia in acc. with TP TC 012/2011:
0Ex ia IIC T5/T4 Ga
0832-CPD-0313
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 5 - 10
Product Sheet | Detecon
Standard detectors
Ionisation smoke detectors, addressable, Ex
IMX95 Ex
Order no.: 901317
Analog addressable ionisation smoke detector for Ex zone 0
designed for use in areas where occasionally low dust levels
are encountered.
Provided for use on FMZ 5000 ¿re alarm control panels with
Loop AP protocol.
Addressing via separate address card. The address can also
be changed after installation.
Detector with intrinsically safe electronics for operation in
hazard areas.
Connection only via an Ex Loop AP 24 V safety barrier.
Product features
Not included in delivery
•
Constant monitoring of sensors, soft- and hardware inclusive of microcontroller.
•
Non-volatile memory for detector data.
•
Day/night switchover via control panel with differing sensitivities.
•
Detector for use in zone 0.
Technical specifications
Detection method
Technology / protocol
Integrated isolator
Radioactive isotope
Radioactivity
Air speeds
Loop AP / XP95
no
Americium 241
33.3 kBq
Operating voltage
max. 10 m (394 inch)/s
corresponding to max. 600 m
(0.37 miles) a.s.l.
14 V - 22 V DC
Quiescent current
0.3 mA
Atmospheric pressure
Alarm indication
1 LED red
Operating temperature, T4
-20 °C to +60 °C (-4 °F to +140 °F)
Operating temperature, T5
-20 °C to +45 °C (-4 °F to +113 °F)
IP rating (EN 60529)
IP 43
Enclosure material
Relative humidity
(IEC721-3-3)
Speci¿cation according to
White polycarbonate
0 to 95%
no condensation
EN 54 Part 7
Weight
105 g (0.2 lbs)
100 x 42 mm (DxH)
3.9 x 1.7 inch (DxH)
Dimensions
P31.311.180-2en / 01.14
ionization chamber
Detector base
Address card
Safety barrier Ex standard
Loop AP protocol interface
see accessories
901297
901324
901322
Connection / mounting
Connection cable
2-lead
Recommended cable, standard
747180
J-Y(ST)Y-2x2x0.8 mm
Conducter cross-section max. 2.5 mm2 (0.004 square inch)
Electrostatic shielding
not required
Note
Analog addressable detectors for hazard areas may be used
used in the Loop AP branch. To archive this con¿guration the
protocol interface and Ex Loop AP safety barrier have to be
used.
Approvals / marking
Ex conformity in acc. with 94/9/EG
x II 1G Ex ia IIC T5 Ga (-20°C ” Ta ” +45°C)
x II 1G Ex ia IIC T4 Ga (-20°C ” Ta ” +60°C)
EC type approval certi¿cate:
BAS 02 ATEX 1289
Ex conformity Russia in acc. with TP TC 012/2011:
0Ex ia IIC T5/T4 Ga
0832-CPD-0312
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 5 - 11
Product Sheet | Detecon
Standard detectors
Heat detectors, addressable, Ex
WMX95 Ex
Order no.: 901319
Analog addressable maximum differential heat detector for
Ex zone 0 for use in areas in which interferance such as
smoke are likely to be encountered (e.g. of¿ce- and storage
areas, industrial plant or test facilities).
Provided for use on FMZ 5000 ¿re alarm control panels with
Loop AP protocol.
Addressing via separate address card. The address can also
be changed after installation.
Detector with intrinsically safe electronics for operation in
areas hazard.
Connection only via an Ex Loop AP 24 V safety barrier.
Not included in delivery
Product fearures
•
Constant monitoring of sensors, soft- and hardware inclusive of microcontroller.
•
Detector for use in Zone 0.
Technical specifications
Detection method
Technology / protocol
NTC- temperature sensor
Loop AP / XP95
no
Operating voltage
14 V - 22 V DC
Quiescent current
0.3 mA
Activating temperature
Operating temperature, T4
Operating temperature, T5
IP rating (EN 60529)
1 LED red
approx. +60 °C (+140 °F)
-20 °C to +60 °C
(-4 °F to +140 °F)
-20 °C to +45 °C
(-4 °F to +113 °F)
IP 53
Enclosure material
Relative humidity
(IEC721-3-3)
Speci¿cation according to
White polycarbonate
0 to 95%
no condensation
EN 54 Part 5
Weight
105 g (0.2 lbs)
100 x 42 mm (DxH)
3.9 x 1.7 inch (DxH)
Dimensions
see accessories
901297
901324
901322
Connection / mounting
Integrated isolator
Alarm indication
Detector base
Address card
Safety barrier Ex standard
Loop AP protocol interface
Connection cable
2-lead
Recommended cable, standard
747180
J-Y(ST)Y-2x2x0.8 mm
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Electrostatic shielding
not required
Note
Analog addressable detectors for hazard areas are to be
used in the Loop AP branch. For this purpose the protocol
interface and Ex Loop AP safety barrier have to be used.
Approvals / marking
P31.311.230 - 2en / 01.14
Ex conformity in acc. with 94/9/EG
x II 1G Ex ia IIC T5 Ga (-20°C ” Ta ” +45°C)
x II 1G Ex ia IIC T4 Ga (-20°C ” Ta ” +60°C)
EC type approval certi¿cate:
BAS 02 ATEX 1289
Ex conformity Russia in acc. with TP TC 012/2011:
0Ex ia IIC T5/T4 Ga
0832-CPD-0311
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 5 - 12
Product Sheet | Detecon
Standard detectors
Detector accessories, addressable, Ex
Detector base BAX 215 Ex
Order no.: 901320
Base for all analog addressable Ex-detectors inc. address
card with large size contact screws for all connections. Simple mounting and easy insertion of detectors by clockwork
rotation with subsequent locking. Plug-in a detector remote
indicator is available.
Base for use in areas with a risk of explosion.
Connection only via an Ex Loop AP 24 V Ex security barrier.
Included in delivery
1 detector socket in the standard version inc. address card
from 1 to 126.
Technical specifications
Material
PC
Integrated isolator
no
IP rating (EN60529)
Colour
Operating temperature, T4
Operating temperature, T5
Weight
Mounting materials
IP 43
white
-20 °C to +60 °C
(-4 °F to +140 °F)
-20 °C to + 45 °C
(-4 °F to +113 °F)
55 g (0.1 lbs)
100 x 8 mm (DxH)
3.9 x 0.3 inch (DxH)
Approvals / marking
Ex conformity in acc. with 94/9/EG
x II 1G Ex ia IIC T5 Ga (-20°C ” Ta ” +45°C)
x II 1G Ex ia IIC T4 Ga (-20°C ” Ta ” +60°C)
EC type approval certi¿cate:
P31.311.730 - 1en / 01.14
Dimensions
Not included in delivery
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 5 - 13
BAS 02 ATEX 1289
Product Sheet | Detecon
Standard detectors
Optical smoke detectors, conventional
OMX 1001C
Order no.: 800831
Conventional optical smoke detector. Designed for use in
areas with smoke in case of ¿re.
Smoke detector with drift compensation fore use in industrial
environments.
Product features
Not included in delivery
•
Constant function monitoring of sensors, software and
hardware including the microcontroller.
•
Normal operation indication by green Àashing light.
Detector base
End of line-resistor 1.8 K / 0.5 W
Dust cover
•
Automatic drift compensation.
•
Robust smoke detector
Spare parts
Insert OMX (Can)
Basket IMX (Dust-proof grid)
Technical specifications
Detection method
Alarm threshold
(light obscuration)
Technology
approx. 0.16 dB/m (39 inch)
Operating voltage
7.6 V - 13.2 V DC
Quiescent current
approx. 0.13 mA
Alarm current
Infrared photo diode
conventional
1 LED red, permanent light
Normal operation indication
1 LED green, Àashing light
Operating temperature
IP rating (EN 60529)
Enclosure material
Relative humidity
(IEC721-3-3)
Weight
Connection / mounting
Connection cable standard detector
2-lead
External Indication
1-lead
Max. Line length
max. 700 m at 0.8 mm
(max 0.43 miles at 0.03 inch)
Recommended cable
JY (St) Y 2x2x0.8 mm
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
existing
Approvals / marking
G 200005
0786-CPD-20131
-20 °C to +60 °C (-4 °F to +140 °F)
IP 43
white polycarbonate
0 to 95%
no condensation
220 g (0.5 lbs)
113 x 68 mm (DxH)
4.5 x 2.7 inch (DxH)
P31.311.110 - 2en / 01.14
Dimensions
801023
253250
approx. 18 mA
Alarm indication
Electrostatic shielding
see accessories
675235
894760
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 5 - 14
Product Sheet | Detecon
Standard detectors
Ionisation smoke detectors, conventional
IMX 1001E
Order no.: 754450
Conventional ionisation smoke detector. Designed for use in
areas with smoke in case of ¿re.
Robust smoke detector with a dual ionisation chamber for
use in industrial environments.
Product features
Not included in delivery
•
Drift compensation by dual ionization.
•
Robust smoke detector.
Detector base
End of line-resistor 1.8 K / 0.5 W
Dust cover
Technical specifications
Detection method
Technology
Connection / mounting
double ionization chamber
conventional
Operating voltage
7.6 V - 13.2 V DC
Quiescent current
approx. 0.08 mA
Alarm current
Alarm indication
Sensitivity
approx. 20 mA
1 LED red
y = 0.8
Air Àow
max. 5 m/s
Radioactivity Am241
Electrostatic shielding
Operating temperature
IP rating (EN 60529)
Enclosure material
Relative humidity
(IEC721-3-3)
Weight
2.8 kBq
existing
-20 °C up to +60 °C
(-4 °F to +140 °F)
IP 43, with membrane plug and
sealing of the mounting holes
Polycarbonate white
max. 95%
Avoid condensation
230 g (0.5 lbs)
113 x 68 mm (DxH)
4.5 x 2.7 inch (DxH)
Connection cable standard detector
2-lead
External Indication
1-lead
Recommended cable
JY (St) Y 2x2x0.8 mm
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Notes
The detector contains radioactive materials. The operating
instructions and current laws and regulations on radiation
protection must be observed.
Approvals / marking
G 28107
0786-CPD-20211
P31.311.150en / 01.14
Dimensions
see accessories
675235
894760
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 5 - 15
Product Sheet | Detecon
Standard detectors
Heat detectors, conventional
WMX 1000D60
Order no.: 747866
Conventional combined differential and static head detector.
Designed for areas with rapid rise of temperature caused by
Àames.
Heat detector with 2 temperature sensors for use in industrial
environments.
Product features
Not included in delivery
•
Adaptation to ambient temperature by 2 temperature
sensors.
•
Combined differential and static measurement.
Detector base
End of line-resistor 1.8 K / 0.5 W
Dust cover
•
Robust heat detector.
Connection / mounting
Technical specifications
Detection method
Technology
NTC - Temperaturesensor
conventional
Operating voltage
7.6 V - 13.2 V DC
Quiescent current
approx. 0.07 mA
Alarm current
Alarm indication
Temperature class, rate of
rise measurement
Static threshold value
Electrostatic shielding
Operating temperature
IP rating (EN 60529)
Enclousure material
Relative humidity
(IEC721-3-3)
Weight
Connection cable standard detector
2-lead
External Indication
1-lead
Recommended cable
JY (St) Y 2x2x0.8 mm
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Approvals / marking
G 27611
0786-CPD-20208
approx. 15 mA
1 LED red
Class A1,
acc. to EN54-5: 2000 / A1:2002
+54 °C to +62 °C
(+129.2 °F to +143.9 °F)
not required
-20 °C to +50 °C
(-4 °F to +122 °F)
IP 23, with membrane plug and
sealing of the mounting holes
white polycarbonate
max. 95%
no condensation
140 g (0.3 lbs)
113 x 68 mm (DxH)
4.5 x 2.7 inch (DxH)
P31.311.210 - 1en / 01.14
Dimensions
see accessories
675235
894760
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 5 - 16
Product Sheet | Detecon
Standard detectors
Heat detectors, conventional
WMX1000D90
Order no.: 747878
Technical specifications
Temperature class, rate of
rise measurement
Static threshold value
Operating temperature
G 29109
0786-CPD-20209
Otherwise like Order no. 747866
P31.311.210 - 1en / 01.14
Weight
Approvals / marking
Class C,
acc. to EN54-5: 2000 / A1:2002
+84 °C to +100 °C
(+183.2 °F to +212 °F)
-20 °C to +80 °C
(-4 °F to +176 °F)
140 g (0.3 lbs)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 5 - 17
Product Sheet | Detecon
Standard detectors
Detector accessories, conventional
Detector base metric, 3-pin
Order no.: 903502
Standard detector base.
Not included in delivery
Membrane plug M16x1.5 (side cable entry)
Membrane plug M20 PE (rear cable entry)
End cap white (side cable entry)
End of line-resistor 1.8 K /0.5 W
Clamping screws
Technical specifications
Enclousure material
Relative humidity
Colour
Operating temperature
Weight
Dimensions
Polycarbonate
max. 100 %
white
-40 °C to +100 °C
(-40 °F to +212 °F )
100 g (0.2 lbs)
113 mm (D)
4.5 inch (D)
Detector base metric, 5-pin
902313
902541
795007
675235
Spare parts
Contact blade
Terminal
Cheese-head screw M4x6 DIN84
Serrated lock washer A4,3 DIN6798
761756
212400
237829
606073
Order no.: 903503
Detector base with remote indicator.
Not included in delivery
Technical specifications
Enclousure material
Relative humidity
Colour
Operating temperature
P31.311.710 - 2en / 01.14
Weight
Dimensions
Polycarbonate
max. 100 %
white
-40 °C to +100 °C
(-40 °F to +212 °F)
100 g (0.2 lbs)
113 mm (D)
4.5 inch (D)
Membrane plug M16x1.5 (side cable entry)
Membrane plug M20 PE (rear cable entry)
End cap white (side cable entry)
End of line-resistor 1.8 K /0.5 W
Card clock module for remote indication
Clamping screws
902313
902541
795007
675235
831953
Spare parts
Contact blade
Terminal
Cheese-head screw M4x6 DIN84
Serrated lock washer A4.3 DIN6798
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 5 - 18
761756
212400
237829
606073
Product Sheet | Detecon
Standard detectors
Detector accessories, conventional
Dust cover for white detectors
Order no.: 894760
Protection against pollution of the detector before commissioning.
Included in delivery
1 packaging unit (50 Piece)
Note
Dust cover to be removed with detector servicing tool.
Technical specifications
Enclousure material
PVC 0.4 mm (0.01 inch)
Colour
orange
Weight
4 g (0.01 lbs)
80.5 x 23 mm (DxH)
3.2 x 0.9 inch (DxH)
Dimensions
Bypass detector BMX1001
Order no.: 719754
The BMX1001 bypass box for the accomodation of an optical
smoke detector OMX1001C to monitor exhaust air and air
conditioning ducts with higher air speeds.
Not included in delivery
Optical smoke detector OMX1001C
Loctite AVK 586, bottle 50 ml
Assembly tool for rivet nuts
800831
886226
Connection / mounting
Recommended cable
Technical specifications
Air Àow
Detector slot
Pipe for bypass detector
P31.311.710 - 2en / 01.14
Enclousure material
Ambient temperature
IP rating
Weight with 2 pipes
Dimensions
1 m (39 inch)/s to max.
20 m (787 inch)/s
1 Detector base 5-pin
2 threaded pipes DN15 galvanized,
540 mm (21.6 inch)
Aluminium diecast, grey
-20 °C to +60 °C
(-4 °F to +140 °F)
IP 23
J-Y (St) Y 2x2x0.8 mm, red
Note
VdS approval only for bypass box with optical smoke detector
OMX1001C.
An approval for the control of ¿re damper does not exist.
Approvals / marking
G 28406
3500 g (7.7 lbs)
130 x 165 x 95 mm (BxHxT)
4.5 x 2.7 inch (DxHxT)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 5 - 19
Product Sheet | Detecon
Standard detectors
Optical smoke detectors, conventional
OMX ORB
Order no.: 905567
Conventional optical smoke detector for application in areas
where formation of smoke is to be anticipated in case of ¿re.
Smoke detector with special design that uses algorithms for
evaluation, thus achieving high reliability in early ¿re detection.
Product features
Not included in delivery
•
Permanent function monitoring of the sensors, software
and hardware by means of a microcontroller.
•
Algorithmic signal evaluation.
Detector base BAX ORB
End of line-resister 1.8 K / 0.5 W
Relay socket BAR ORD R
•
Adaptation to the environmental conditions through automatic drift compensation.
Technical specifications
Detection method
Technology
Infrared photo diode
conventional
Operating voltage
8.5 V - 33 V DC
Quiescent current
approx. 0.1 mA
40 mA at 24 V
20 mA at 12 V
1 LED red, steady light
-40 °C to +70 °C
(-40 °F to +158 °F)
IP 23D
Alarm current
Alarm indication
Operating temperature
IP rating (EN 60529)
Enclosure material
Relative humidity
(IEC721-3-3)
Weight
Connection / mounting
Connection cable
External Indication
Max. Line length
2-lead
1-lead
max. 700 m at 0.8 mm
(max 0.43 miles at 0.03 inch)
JY (St) Y 2x2x0.8 mm
max. 2.5 mm2 (0.004 square inch)
Recommended cable
Conductor cross-section
Approvals / marking
G 204039
0832-CPD-0035
white polycarbonate
0 to 98%
no condensation
75 g (0.2 lbs)
100 x 42 mm (dia.xH)
3.9 x 1.7 inch (dia.xH)
P31.311.110 - 1en / 01.14
Dimensions
905564
675235
906917
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 5 - 20
Product Sheet | Detecon
Standard detectors
Multisensor detectors, conventional
Multisensor detector OWMX ORB
Order no.: 905566
Conventional multisensor detector consisting of a combination of optical smoke detector and heat detector. Designed for
the application in areas where periodically occurring sources
of deception are to be anticipated. The multisensor detector
is a thermally supported smoke detector. Its sensitivity is
considerably increased in case of Àaming ¿res.
Product features
Not included in delivery
•
Permanent function monitoring of the sensors, software
and hardware including the microcontroller.
•
Evaluation of the signals with algorithms.
•
Adaptation to the environmental conditions through automatic drift compensation.
Technical specifications
Detection method smoke
Detection method heat
Infrared photo diode
8.5 V - 33 V DC
Quiescent current
0.1 mA
40 mA at 24 V
20 mA at 12 V
1 LED red
-40 °C to +70 °C
(-40 °F to +158 °F)
IP 23D
Alarm current
Alarm indication
Operating temperature
IP rating (EN 60529)
Dimensions
Connection cable standard detector
2-lead
External indication
1-lead
Recommended cable
JY (St) Y 2x2x0.8 mm
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
conventional
Operating voltage
white polycarbonate
0 to 98%
no condensation
80 g (0.2 lbs)
100 x 50 mm (dia.xH)
(3.9 x 2 inch (dia.xH)
Approvals / marking
0832-CPD-0036
P31.311.510en / 01.14
G 204040
905564
675235
906917
Connection / mounting
NTC - Temperatursensor
Technology
Enclousure material
Relative humidity
(IEC721-3-3)
Weight
Detector base BAX ORB
End of line-resistor 1.8 K / 0.5 W
Relay socket BAX ORB R
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 5 - 21
Product Sheet | Detecon
Standard detectors
Heat detectors, conventional
WMX ORB A1R
Order no.: 905565
Conventional heat differential/maximum detector. Designed
for application in areas where rapid development of heat
through Àames is to be anticipated.
Product features
Not included in delivery
•
Detector base BAX ORB
End of line-resistor 1.8 K / 0.5 W
Relay socket BAX ORB R
Combined differential/maximum evaluation of the
increases in temperature.
Technical specifications
Detection method
Technology
Connection / mounting
NTC - Temperaturesensor
conventional
Operating voltage
8.5 V - 33 V DC
Quiescent current
approx. 0.1 mA
40 mA at 24 V
20 mA at 12 V
1 LED red
Class A1,
acc. EN54-5: 2000 / A1:2002
+54 °C to +62 °C
(+129.2 °F to +143.6 °F )
-40 °C to +70 °C
(-40 °F to +158 °F)
IP 23 D
Alarm current
Alarm indication
Temperature class,
rate of rise measurement
Statically trip point
Operating temperature
IP rating (EN 60529)
Enclousure material
Relative humidity
(IEC721-3-3)
Weight
Connection cable standard detector
2-lead
External indication
1-lead
Recommended cable
JBY (St) Y 2x2x0.8 mm (0.03inch)
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Approvals / marking
G 204033
0832-CPD-0029
white polycarbonate
max. 98%
no condensation
70 g (0.2 lbs)
100 x 42 mm (dia.xH)
3.9 x 1.7 inch (dia.xH)
P31.311.210 - 2en / 01.14
Dimensions
905564
675235
906917
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 5 - 22
Product Sheet | Detecon
Standard detectors
Detector accessories, conventional
Detector base BAX ORB
Order no.: 905564
Standard detector base.
Not included in delivery
Mounting hardware.
Technical specifications
Enclousure material
Relative humidity
Colour
Operating temperature
Weight
Dimensions
Approvals / marking
Polycarbonate
0 to 98 %
no condensation
white
-40 °C to +70 °C
(-40 °F to +158 °F)
60 g (0.1 lbs)
100 mm (D)
3.9 inch (D)
Relay base BAX ORB R
G 204039
0832-CPD-0035
Order no.: 906917
Standard detector base with relay.
Not included in delivery
mounting hardware.
Technical specifications
Enclousure material
Relative humidity
Colour
P31.311.710 - 1en / 01.14
Operating temperature
Weight
Dimensions
Approvals / marking
Polycarbonate
0 to 98 %
no condensation
white
-40 °C to +70 °C
(-40 °F to +158 °F)
80 g (0.2 lbs)
100 mm (D)
3.9 inch (D)
G 204039
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
0832-CPD-0035
Chapter 5 - 23
Product Sheet | Detecon
Standard detectors
Optical smoke detectors, conventional, Ex
OMX 1001C Ex
Order no.: 800833
Conventional intrinsically safe optical smoke detector for Ex
zone 1. Designed for use in areas with smoke in case of ¿re.
Robust smoke detector with drift compensation for use in
industrial environments.
Designed for use in hazard areas connected to a safety
barrier Ex Standard 9 V. The barrier has to be placed in non
hazard areas.
Product features
Included in delivery
•
Constant funktion monitoring of sensors, software and
hardware including the microcontroller.
•
Normal operation indication by green Àashing light.
1 Optical smoke detector
1 Operating manual, German
1 Operating manual, English
•
Automatic drift compensation.
•
Robust smoke detector.
Not included in delivery
Detector base
Technical specifications
Detection method
Measurement chamber
sensitivity
Number of detectors per line
Technology
903502 or 903503
see detectors accessories, conventional
End of line-resistor 1.8 K / 0.5 W
675235
Dust cover
894760
Safety barrier IS conventional 9 V
904991
approx. 0.16 dB/m (39.4 inch)
max. 24
conventional
7.6 V - 13.2 V DC
Quiescent current
approx. 0.35 mA
approx. 18 mA
Connection / mounting
Connection cable standard detector
2-lead
External Indication
1-lead
Recommended cable
JEY (St) Y 2x2x0.8 mm, blue
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Alarm indication
1 LED red, permanent light
Note
Normal operation indication
1 LED green, Àashing light
The detector housing has a high surface resistance. Avoid
electrostatic charging.
Electrostatic shielding
Operating temperature, T4
Operating temperature, T6
Storage temperature
IP rating (EN 60529)
Enclosure material
Relative humidity
(IEC721-3-3)
Weight
P31.311.130 - 1en / 01.14
Infrared photo diode
Operating voltage
Alarm current
901123
901772
Dimensions
existing
-20 °C to +60 °C
(-4 °F to +140 °F)
-20 °C to +40 °C
(-4 °F to +104 °F)
-40 °C to +85 °C
(-40 °F to +185 °F)
IP 43, with membrane plug and
sealing of the mounting holes
white polycarbonate
max. 95% at 35 °C (+95 °F)
no condensation
240 g (0,5 lbs)
113 x 68 mm (DxH)
4.5 x 2.7 inch (DxH)
Approvals / marking
Ex conformity in acc. with 94/9/EG
x II 2G Ex ia IIC T6...T4 Gb
EC type approval certi¿cate:
DMT 00 ATEX E 043
Ex conformity Russia in acc. with TP TC 012/2011:
1Ex ia IIC T6/T4 Gb
G 200005
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
0786-CPD-20131
Chapter 5 - 24
Product Sheet | Detecon
Standard detectors
Ionisation smoke detectors, conventional, Ex
IMX 1001E Ex
Order no: 782410
Conventional ionisation smoke detector for Ex zone 1. Designed for use in areas with smoke in case of ¿re.
Robust smoke detector with a dual ionisation chamber for
use in industrial environments.
Designed for use in hazard areas connected to a safety
barrier Ex Standard 9 V. The barrier has to be placed in non
hazard areas.
Product features
Not included in delivery
•
Drift compensation by dual ionization.
Detector base
•
Robust smoke detector.
903502 or 903503
see detectors accessories, conventional
End of line-resister 1.8 K / 0.5 W
675235
Dust cover
894760
Safety barrier IS conventional 9 V
904991
Technical specifications
Detection method
Sensitivity
two coupled ionization chambers
y = 0.8
Technology
conventional
Operating voltage
7.6 V - 13.2 V DC
Quiescent current
approx. 0.08 mA
Alarm current
Alarm indication
Electrostatic shielding
Operating temperature T4
Operating temperature T6
Storage temperature
Max. usage height above
sea level
IP rating (EN 60529)
Enclosure material
Relative humidity
(IEC721-3-3)
Weight
1 LED red
existing
-20 °C to +75 °C
(-4 °F to +167 °F)
-20 °C to +40 °C
(-4 °F to +104 °F)
-30 °C to +80 °C
(-22 °F to +176 °F)
approx. 3500 m (2.17 miles)
IP 43, with membrane plug and
sealing of the mounting holes
white polycarbonate
max. 98% bei 35°C (+95 °F)
Avoid condensation
230 g (0.5 lbs)
113 x 68 mm (DxH)
4.5 x 2.7 inch (DxH)
Connection cable standard detector
2-lead
External Indication
1-lead
Recommended cable
JEY (St) Y 2x2x0.8 mm2, blue
Conductor cross-section
max. 2.5 mm2
Note
The detector housing has a high surface resistance. Avoid
electrostatic charging
The detector contains radioactive materials. The operating
instructions and current laws and regulations on radiation
protection must be observed.
Approvals / marking
Ex conformity in acc. with 94/9/EG
x II 2G Ex ib IIC T6...T4 Gb
EC type approval certi¿cate:
G 28119
BVS 03 ATEX 2110
0786-CPD-20211
P31.311.180 - 1en / 01.14
Dimensions
approx. 20 mA
Connection / mounting
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 5 - 25
Product Sheet | Detecon
Standard detectors
Heat detectors, conventional, Ex
WMX 1000D60 Ex
Order no.: 782422
Conventional combined rate of rise and static heat detector
for Ex zone 1. Designed for areas with rapid rase of temperature by Àames.
Heat detector with 2 temperature sensors for use in industrial
environments.
Designed for use in hazard areas connected to a safety
barrier Ex Standard 9 V. The barrier has to be placed in non
hazard areas.
Product features
Not included in delivery
•
Adaptation to ambient temperature by 2 temperature
sensors.
Detector base
•
Combined differential and static measurement.
•
Robust heat detector.
Technical specifications
Detection method
Technology
Connection / mounting
NTC - temperature sensor
conventional
Operating voltage
7.6 V - 13.2 V DC
Quiescent current
approx. 0.07 mA
Alarm current
Alarm indication
Temperature class, rate of
rise measurement
Static threshold value
Elektrostatic shielding
Operating temperature
IP rating (EN 60529)
Enclosure material
Relative humidity
(IEC721-3-3)
Weight
approx. 15 mA
1 LED red
Class A1,
acc. to EN54-5: 2000 / A1:2002
+54 °C to +62 °C
(+129.2 °F to +143.6 °F)
recommended
-20 °C to +50 °C
(-4 °F to +122 °F)
IP 23, with membrane plug and
sealing of the mounting holes
white polycarbonate
max. 95%
no condensation
140 g (0.3 lbs)
113 x 68 mm (DxH)
4.5 x 2.7 inch (DxH)
Connection cable standard detector
2-lead
External Indication
1-lead
Recommended cable
JEY (St) Y 2x2x0.8 mm, blue
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Note
The detector housing has a high surface resistance. Avoid
electrostatic charging.
Approvals / marking
Ex conformity in acc. with 94/9/EG
x II 2G Ex ib IIC T6...T4 Gb
EC type approval certi¿cate:
BVS 03 ATEX E 104
Ex conformity Russia in acc. with TP TC 012/2011:
1Ex ia IIC T5/T4 Gb
G 27918
0786-CPD-20208
P31.311.230 - 1en / 01.14
Dimensions
903502 or 903503
see detectors accessories, conventional
End of line-resistor 1.8 K / 0.5 W
675235
Dust cover
894760
Safety barrier IS conventional 9 V
904991
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 5 - 26
Product Sheet | Detecon
Standard detectors
Heat detectors, conventional, Ex
WMX1000D90 Ex
Order no.: 782434
Technical specifications
Approvals / marking
Temperature class, rate of
rise measurement
Static threshold value
Operating temperature
Weight
Class C,
acc. to EN54-5: 2000 / A1:2002
+84 °C to +100 °C
(+183.2 °F to +212 °F)
-20 °C to +80 °C
(-4 °F to +176 °F)
140 g (0.3 lbs)
Ex conformity in acc. with 94/9/EG
x II 2G Ex ib IIC T6...T4 Gb
EC type approval certi¿cate:
BVS 03 ATEX E 104
Ex conformity Russia in acc. with TP TC 012/2011:
1Ex ia IIC T5/T4 Gb
G 27918
0786-CPD-20209
Otherwise like Order no.: 782422
WMX1000D105 Ex
Order no.: 907368
Technical specifications
Approvals / marking
Temperature class, rate of
rise measurement
Static threshold value
Operating temperature
Weight
Class D,
acc. to EN54-5: 2000 / A1:2002
+100 °C to +115 °C
(+212 °F to +239 °F)
-20 °C to +80 °C
(-4 °F to +176 °F)
140 g (0.3 lbs)
Ex conformity in acc. with 94/9/EG
x II 2G Ex ib IIC T6...T4 Gb
EC type approval certi¿cate:
BVS 03 ATEX E 104
Ex conformity Russia in acc. with TP TC 012/2011:
1Ex ia IIC T5/T4 Gb
Otherwise like Order no.: 782422
WMX1000D80M Ex
Order no.: 903508
Technical specifications
Approvals / marking
Static threshold value
Operating temperature
P31.311.230 - 1en / 01.14
Weight
+77 °C to +83 °C
(+170.6 °F to +181.4 °F)
-20 °C to +70 °C
(-4 °F to +158 °F)
130 g (0.3 lbs)
Ex conformity in acc. with 94/9/EG
x II 2G Ex ib IIC T6...T4 Gb
EC type approval certi¿cate:
BVS 03 ATEX E 104
Ex conformity Russia in acc. with TP TC 012/2011:
1Ex ia IIC T5/T4 Gb
Otherwise like Order no.: 782422
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 5 - 27
Product Sheet | Detecon
Standard detectors
Detector accessories
Deckhead mounting box ACX 196
Order no.: 905403
Back box for detector base for surface mounting, with lateral
cable entry for M20 cable glands. Stable ABS enclosure in
robust design.
Not included in delivery
Cable glands M20x1.5
Blind plug
902901
902922
Technical specifications
Material
ABS
Weight
Dimensions
404 g (0.9 lbs)
146 x 38 mm (dia. x H)
5.8 x 1.5 inch (dia. x H)
Cable floor-detector holder BHX 1000,
d=20 mm to 25 mm (0.78 to 0.98)
Order no.: 908691
Cable Àoor-detector holder for underÀoor installation.
The standard fastener is designed for round pipes with a
diameter of 20 - 25 mm (0.78 to 0.98 inch). Other fasteners
on request.
The plate area is designed for smoke and heat detector
bases of many detector suppliers.
Included in delivery
1 packaging unit (10 x)
Cable Àoor-detector holder BHX 1000
2 mounting screws 4.2 x 13 (DIN 7981-St)
Technical specifications
Material
Sheet steel, powder-coated
Colour
Operating temperature
Weight
P31.311.740en / 01.14
Dimensions
RAL 7035
-20 °C to +70 °C
(-4 °F to +158 °F)
290 g (0.6 lbs)
112 x 330 mm (dia. x H)
4.4 x 13 inch (dia. x H)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 5 - 28
Product Sheet | Detecon
Standard detectors
Detector accessories
Parallel indicator LMX5000
Order no.: 908499
Additional alarm indication for detectors with non visible
alarm LED e.g. in false Àoors.
Insertable for Loop AP, MxLoop® and conventional technology.
Do not use the parallel indicator in hazard areas.
Not included in delivery
Clamping screws
Approvals / marking
Technical specifications
Nominal voltage
Loop AP
MxLoop®
conventional
Electrostatic shielding
Enclosure material
Relative humidity
Ambient temperature
IP rating
Weight
ABS, RAL9010 - white
98 %, avoid condensation
-10 °C to +60 °C
(-14 °F to +140 °F)
IP 30
66 g (0.2 lbs)
84 x 84 x 35 mm (WxHxD)
3.3 x 3.3 x 1.4 inch (WxHxD)
P31.311.740en / 01.14
Dimensions
24 V DC
12 V DC
9 V DC
not required
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 5 - 29
Product Sheet | Detecon
Standard detectors
Detector accessories
Junction box ACX 204
Order no.: 901247
Junction box for Àush mounted installation by the customer in
concrete ceiling slabs, with prefabricated attachment points
for the detector base. Break-off tabs for cable entries, M16
and M20 wiring conduit.
Notes
Not applicable in combination with:
- detector base metric, 3-pin
- detector base metric, 5-pin
- and the associated detectors series
Approvals / marking
Technical specifications
Material
Dimensions
Backplate ACX 233
903502
903503
PC
100 x 8 mm (dia. x H)
3.9 x 0.3 inch (dia. x H)
Order no.: 901245
Protection plate against dust and water to add to the detector
base during assembly. When using addressable detectors
the number identi¿cation must be removed and inserted at
the points provided in the backplate.
Notes
Not applicable in combination with:
- detector base metric, 3-pin
- detector base metric, 5-pin
- and the associated detectors series
P31.311.740en / 01.14
Approvals / marking
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 5 - 30
903502
903503
Product Sheet | Detecon
Standard detectors
Detector accessories, conventional,Ex
Junction box Ex
Order no.: 900288
Junction box for hazard areas, can be used in zone 1
Included in delivery
1 Junction box Ex with 4 cable glands M25 for cable Ø 10 17 mm and 2 closures M25.
6 clamps, clamping range to 2.5 mm2 (0.004 square inch)
Technical specifications
Material
Polyamid
IP rating (EN60529)
Colour
Operating temperature
Weight
black
-20 °C to +40 °C
(-4 °F to +104 °F)
300 g ( 0.66 lbs)
122 x 180 x 61 mm (WxHxD)
4.8 x 7.1 x 2.4 inch (WxHxD)
Not included in delivery
Mounting hardware
Approvals / marking
Ex conformity in acc. with 94/9/EG
x II 2G Ex dem ia II, IIC T6
EC type approval certi¿cate:
P31.311.730 - 2en / 01.14
Dimensions
IP 66
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 5 - 31
PTB 00 ATEX 3108
Product Sheet | Detecon
Standard detectors
Modules, addressable, DIN rail mounting
Input module IUX 760 M-I
Order no.: 908531
Miniature interface for use in devices with little space.
The mini switch monitor monitors the state of one or more dry
normally open contacts and reports the status to a ¿re alarm
panel.
Applicable for operation in ¿re alarm panels with Loop AP
protocol.
Optional equipped with interrupt for rapid alarm signals as
with a manual call point.
The states "quiescent", "pre-alarm", "alarm" and "fault" are
recognised.
Addressing via DIP switches; the address can also be
modi¿ed after installation.
Inputs
Outputs
Connection / mounting
: 1
: 0
Technical specifications
Operating voltage
Quiescent current at 24 V DC:
Min. (quiescent)
Max. (alarm input)
Alarm indication
17 V - 28 V DC
0.2 mA
3.6 mA
red LED
Bus activity indication
green LED
Short-circuit indication
yellow LED
Integrated isolator
IP rating (EN 60529)
Dimensions
Contact input:
Voltage at contact input
Cable resistance max.
Terminating resistor
Pre-alarm resistance
Main alarm resistance
9 - 11 V DC
50 Ohm
20 kOhm
10 kOhm
1 kOhm
yes
-20 °C to +70 °C
(-4 °F to +158 °F)
IP 20
Operating temperature
Technology / protocol
Relative humidity
(IEC721-3-3)
Weight
Connection cable
2-lead
Recommended cable, standard
747180
J-Y(ST)Y-2x2x0.8 mm
Conductor cross-section max. 1,5 mm2 (0.002 square inch)
Electrostatic shielding
not required
Loop AP / XP95
0 to 95%
no condensation
30 g (0.1 lbs)
39 x 39 x 20 mm (WxHxD)
1.5 x 1.5 x 0.8 inch (WxHxD)
Approvals / marking
0832-CPD-1072
P31.311.810 - 3en / 01.14
G 210034
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 5 - 32
Product Sheet | Detecon
Standard detectors
Modules, addressable, DIN rail mounting
Input module IUX 822 R
Order no.: 905395
Analog addressable input module for monitoring a dry contact
including line monitoring.
DIN rail (R) installation version.
The states "quiescent", "alarm" and "fault" are recognised.
Applicable for operation in ¿re alarm panels with Loop AP
protocol.
Addressing via DIP switches; the address can also be
modi¿ed after installation.
Inputs
Outputs
Connection / mounting
: 1
: 0
Connection cable
2-lead
Recommended cable, standard
747180
J-Y(ST)Y-2x2x0.8 mm
Conductor cross-section max. 1.5 mm2 (0.002 square inch)
Electrostatic shielding
not required
Technical specifications
Operating voltage
Quiescent current at 24 V DC:
Min. (quiescent)
Max (short circuit input,
LED on)
Indication of closed input
Fault indication
Integrated isolator
Operating temperature
IP rating (EN 60529)
Technology / protocol
Relative humidity
(IEC721-3-3)
Speci¿cation according to
Weight
Dimensions
17 V - 28 V DC
0.73 mA
5.6 mA
red LED
yellow LED
Contact input:
Voltage at contact input
Cable resistance max.
Terminating resistor
Pre-alarm resistance
Main alarm resistance
9 - 11 V DC
50 Ohm
20 kOhm
10 kOhm
1 kOhm
no
-20 °C to +70 °C
(-4 °F to +158 °F)
IP 20
Loop AP / XP95
0 to 95%
no condensation
CEA GEI 1-052 (6/97)
95 g (0.2 lbs)
110 x 107 x 20 mm (WxHxD)
4.3 x 4.2 x 0.8 inch (WxHxD)
Approvals
P31.311.810 - 1en / 01.14
0832-CPD-0857
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 5 - 33
Product Sheet | Detecon
Standard detectors
Modules, addressable, DIN rail mounting
Input/output module IOX 821 R
Order no.: 905558
Analog addressable input module for monitoring a dry contact
including line monitoring.
DIN rail installation version.
The states "quiescent", "alarm" and "fault" are recognised.
The alarm status can be set with 30 seconds delay via a
DIP switch.
An opto-isolator output is available and can be used with
additional electronics to reset detectors.
Applicable for operation in ¿re alarm panels with Loop AP
protocol.
Addressing via DIP switches; the address can also be
modi¿ed after installation.
Inputs
Outputs
: 1
: 1 (opto-isolator)
Connection / mounting
Technical specifications
Operating voltage
Quiescent current at 24 V DC:
Min. (quiescent)
Max. (short circuit input,
LED on)
Indication of closed input
Fault indication
Integrated isolator
Operating temperature
IP rating (EN 60529)
Technology / protocol
Relative humidity
(IEC721-3-3)
Speci¿cation according to
Weight
Dimensions
17 V - 28 V DC
0.73 mA
5.6 mA
red LED
yellow LED
no
-20 °C to +70 °C
(-4 °F to +158 °F)
IP 20
Loop AP / XP95
0 to 95%
no condensation
CEA GEI 1-052 (6/97)
Connection cable
2-lead
Recommended cable, standard
747180
J-Y(ST)Y-2x2x0.8 mm
Conductor cross-section max. 1.5 mm2 (0.002 square inch)
Electrostatic shielding
not required
Contact input:
Voltage at contact input
Cable resistance max.
Terminating resistor
Pre-alarm resistance
Main alarm resistance
9 - 11 V DC
50 Ohm
20 kOhm
10 kOhm
1 kOhm
Opto-isolator output:
Voltage range
Guaranteed current
5 - 30 V DC
1 mA
95 g (0.2 lbs)
110 x 107 x 20 mm (WxHxD)
4.3 x 4.2 x 0.8 inch (WxHxD)
Approvals / marking
P31.311.810 - 4en / 01.14
0832-CPD-0856
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 5 - 34
Product Sheet | Detecon
Standard detectors
Modules, addressable, DIN rail mounting
Input/output module IOX 803 R
Order no.: 905803
Analog addressable input/output module for monitoring a dry
contact including line monitoring and additional opto-isolator
input, and for controlling an output via a relay.
DIN rail installation version.
The states "quiescent", "alarm" and "fault" are recognised.
Applicable for operation in ¿re alarm panels with Loop AP
protocol.
Addressing via DIP switches; the address can also be
modi¿ed after installation.
Inputs
Outputs
: 2 (of which 1 opto-isolator)
: 1
Connection / mounting
Technical specifications
Operating voltage
Quiescent current at 24 V DC:
Min. (quiescent)
Max (short circuit input,
LED on)
Indication of closed input
Active output indication
Fault indication
Integrated isolator
Operating temperature
IP rating (EN 60529)
Technology / protocol
Relative humidity
(IEC721-3-3)
Speci¿cation according to
Weight
Dimensions
17 V - 28 V DC
0.73 mA
5.6 mA
red LED
red LED
yellow LED
no
-20 °C to +70 °C
(-4 °F to +158 °F)
IP 20
Loop AP / XP95
0 to 95%
no condensation
CEA GEI 1-052 (6/97)
95 g (0.2 lbs)
110 x 107 x 20 mm (WxHxD)
4.3 x 4.2 x 0.8 inch (WxHxD)
Connection cable
2-lead
Recommended cable, standard
747180
J-Y(ST)Y-2x2x0.8 mm
Conductor cross-section max. 1.5 mm2 (0.002 square inch)
Electrostatic shielding
not required
Contact input:
Voltage at contact input
Cable resistance max.
Terminating resistor
Pre-alarm resistance
Main alarm resistance
9 - 11 V DC
50 Ohm
20 kOhm
10 kOhm
1 kOhm
Opto-isolator input:
Voltage range
Impedance
max. 35 V DC
10 kOhm
Relay output:
Voltage
Current
max. 30 V DC
max. 1 A DC
Approvals / marking
P31.311.810 - 6en / 01.14
0832-CPD-0854
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 5 - 35
Product Sheet | Detecon
Standard detectors
Modules, addressable, DIN rail mounting
Output module OUX 804 R
Order no.: 905402
Analog addressable output module for controlling a dry
contact.
DIN rail (R) installation versions.
Applicable for operation in ¿re alarm panels with Loop AP
protocol.
Addressing via DIP switches; the address can also be
modi¿ed after installation.
Inputs
Outputs
: 0
: 1
Connection / mounting
Technical specifications
Operating voltage
Quiescent current at 24 V DC:
Min. (quiescent)
Max (relay activated
and LEDs on)
Alarm indication
Integrated isolator
Operating temperature
IP rating (EN 60529)
Technology / protocol
Relative humidity
(IEC721-3-3)
Speci¿cation according to
Weight
Dimensions
17 V - 28 V DC
0.73 mA
5.6 mA
red LED
no
-20 °C to +70 °C
(-4 °F to +158 °F)
IP 20
Connection cable
2-lead
Recommended cable, standard
747180
J-Y(ST)Y-2x2x0.8 mm
Conductor cross-section max. 1.5 mm2 (0.002 square inch)
Electrostatic shielding
not required
Relay output:
Voltage
Current
max. 30 V DC
max. 1 A DC
Loop AP / XP95
0 to 95%
no condensation
CEA GEI 1-052 (6/97)
95 g (0.2 lbs)
110 x 107 x 20 mm (WxHxD)
4.3 x 4.2 x 0.8 inch (WxHxD)
Approvals / marking
P31.311.810 - 12en / 01.14
0832-CPD-0855
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 5 - 36
Product Sheet | Detecon
Standard detectors
Modules, addressable, DIN rail mounting
Sounder control module SCX 182 R
Order no.: 905396
Analog addressable sounder control module for controlling
sounders in continuous or pulse-controlled operation with
additional contact input for monitoring the external power
supply of the sounders.
DIN rail (R) installation versions.
Applicable for operation in ¿re alarm panels with Loop AP
protocol.
Addressing via DIP switches; the address can also be
modi¿ed after installation.
Inputs
Outputs
: 1 (contact input)
: 1
Connection / mounting
Technical specifications
Operating voltage
Quiescent current at 24 V DC:
Min. (quiescent)
Max (relay activated
and LEDs on)
Alarm indication
17 V - 28 V DC
1.9 mA
4.5 mA
red LED
Fault indication
yellow LED
Integrated isolator
no
-20 °C to +70 °C
(-4 °F to +158 °F)
IP 20
Operating temperature
IP rating (EN 60529)
Technology / protocol
Relative humidity
(IEC721-3-3)
Speci¿cation according to
Weight
Dimensions
Connection cable
2-lead
Recommended cable, standard
747180
J-Y(ST)Y-2x2x0.8 mm
Conductor cross-section max. 1.5 mm2 (0.002 square inch)
Electrostatic shielding
not required
External power supply
Contact input
9 - 50 V DC
NC/NO contact
Relay output:
Voltage
Current
max. 35 V DC
max. 4 A DC
Loop AP / XP95
0 to 95%
no condensation
CEA GEI 1-052 (6/97)
95 g (0.2 lbs)
110 x 107 x 20 mm (WxHxD)
4.3 x 4.2 x 0.8 inch (WxHxD)
Approvals / marking
0832-CPD-0852
P31.311.810 - 14en / 01.14
G 201095
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 5 - 37
Product Sheet | Detecon
Standard detectors
Modules, addressable, DIN rail mounting
FMZ5000 loop coupler module
Order no.: 902954
Product features
•
For the interface connection of conventional detectors to
a loop of the loop module.
•
The module has four conventional detector zones.
•
Alarm and pre-alarm of every zone are transmitted.
The zones can be deactivated individually via the loop.
Technical specifications
Operating voltage
Quiescent current
Current consumption per line
19 V - 29 V DC
approx. 20 mA
without line terminations
max. 100 mA DC
Line voltage, min
9 V - 19 V DC
Technology / protocol
Alarm /
terminating resistor
Number of lines per module
Loop AP / XP95
470 Ohm /
1.8 kOhm
4
Number of detectors per line
Max. terminal cross-section
Integrated isolator
Ambient temperature
Relative humidity
(IEC721-3-3)
IP rating (EN60529)
Enclosure
2.5 mm (0.004 square inch)
no
-5 °C to +40 °C
(+23 °F to +104 °F)
max. 95 %
no condensation
IP 20
Polyamide PA6.6, green
Installation position
Mounting
P31.311.810 - 10en / 01.14
32
2
Weight
Dimensions
Vertical
Mounting rail 35 DIN 46277,
top hat pro¿le
200 g (0.4 lbs)
35 x 99 x 114.5 mm (WxHxD)
1.4 x 3.9 x 4.5 inch (WxHxD)
Functional module for use in all design variants of the ¿re
alarm system FMZ 5000.
The loop coupler module is a loop node on a loop of the
loop module. It includes 4 conventional detector zones with
their own addresses, which are detected and dealt with by
the ¿re alarm panel like four detectors of the detector loop.
The status of the detector zones and the detectors are reported to the ¿re alarm panel via the con¿gured address.
Detectors can be connected in two-detector dependancies
and groups can be connected in group dependancies.
For use in hazard areas, detectors in intrinsically safe design
can be connected via Zener barriers.
The detector lines have a common base address, which is
set in increments of 4 for all detector lines.
The module has a default con¿guration that can be modi¿ed
using the con¿guration software MxLoopCon,
Order no. 904001.
Application
Mainly for the interface connection of industrial detectors in
conventional detector technology to a Loop AP.
A maximum of 32 automatic Minimax conventional detectors
or any type of conventional detector from other manufacturers with suitable electrical detector parameters (see Technical speci¿cations) or 10 manual call points may be connected
to one conventional line.
The module can be used directly in a ¿re alarm panel.
In such a scenario it is supplied with power via the panel.
Up to 30 modules can be connected to a detector loop.
To supply the conventional lines, the loop coupler module
requires an external 24 V DC power supply.
Included in delivery
Module completely assembled and ready for installation in
the ¿re alarm panel.
Application in potentially explosive atmospheres
Only permitted for use with barrier:
Safety barrier standard 9 V
904991
Note
The module may not be plugged in together with the other
modules.
Approvals / marking
G 209028
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 5 - 38
Product Sheet | Detecon
Standard detectors
Modules, addressable, wall mounting
Input module IUX 843 W-I
Order no.: 905399
Analog addressable input module for monitoring a dry contact
including line monitoring.
In the version for wall-mounted installation (W).
The states "quiescent", "alarm" and "fault" are recognised.
Applicable for operation in ¿re alarm panels with Loop AP
protocol.
Addressing via DIP switches; the address can also be
modi¿ed after installation.
The electronics features an integrated isolator; fault
condition, short circuit or open line is indicated.
Inputs
Outputs
Connection / mounting
: 1
: 0
Connection cable
2-lead
Recommended cable, standard
747180
J-Y(ST)Y-2x2x0.8 mm
Conductor cross-section max. 1.5 mm2 (0.002 square inch)
Electrostatic shielding
not required
Technical specifications
Operating voltage
Quiescent current at 24 V DC:
Min. (quiescent)
Max (short circuit input,
LED on)
Indication of closed input
17 V - 28 V DC
1.25 mA
3.6 mA
red LED
Fault indication
2 yellow LEDs
Integrated isolator
IP rating (EN 60529)
Weight
Dimensions
9 - 11 V DC
50 Ohm
20 kOhm
10 kOhm
1 kOhm
yes
-20 °C to +70 °C
(-4 °F to +158 °F)
IP 54
Operating temperature
Technology / protocol
Relative humidity
(IEC721-3-3)
Speci¿cation according to
Contact input:
Voltage at contact input
Cable resistance max.
Terminating resistor
Pre-alarm resistance
Main alarm resistance
Loop AP / XP95
0 to 95%
no condensation
CEA GEI 1-052 (6/97)
240 g (0.5 lbs)
150 x 90 x 48 mm (WxHxD)
5.9 x 3.5 x 1.9 inch (WxHxD)
Approvals / marking
0832-CPD-0867
P31.311.810 - 2en / 01.14
G 201033
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 5 - 39
Product Sheet | Detecon
Standard detectors
Modules, addressable, wall mounting
Input/output module IOX 841 W-I
Order no.: 905398
Analog addressable input module for monitoring a dry contact
including line monitoring.
Wall-mounted installation version.
The states "quiescent", "alarm" and "fault" are recognised.
The alarm status can be set with 30 seconds delay via a
DIP switch.
An opto-isolator output is available and can be used with
additional electronics to reset detectors.
Applicable for operation in ¿re alarm panels with Loop AP
protocol.
Addressing via DIP switches; the address can also be
modi¿ed after installation.
Inputs
Outputs
The electronics features an integrated isolator; a fault,
short circuit or open line is indicated.
: 1
: 1 (opto-isolator)
Connection / mounting
Technical specifications
Operating voltage
Quiescent current at 24 V DC:
Min. (quiescent)
Max (short circuit input,
LED on)
Indication of closed input
17 V - 28 V DC
1.25 mA
4.2 mA
red LED
Fault indication
2 yellow LEDs
Integrated isolator
yes
-20 °C to +70 °C
(-4 °F to +158 °F)
IP 54
Operating temperature
IP rating (EN 60529)
Technology / protocol
Relative humidity
(IEC721-3-3)
Speci¿cation according to
Weight
Dimensions
Loop AP / XP95
0 to 95%
no condensation
CEA GEI 1-052 (6/97)
Connection cable
2-lead
Recommended cable, standard
747180
J-Y(ST)Y-2x2x0.8 mm
Conductor cross-section max. 1.5 mm2 (0.002 square inch)
Electrostatic shielding
not required
Contact input:
Voltage at contact input
Cable resistance max.
Terminating resistor
Pre-alarm resistance
Main alarm resistance
9 - 11 V DC
50 Ohm
20 kOhm
10 kOhm
1 kOhm
Opto-isolator output:
Voltage range
Guaranteed current
5 - 30 V DC
1 mA
240 g (0.5 lbs)
150 x 90 x 48 mm (WxHxD)
5.9 x 3.5 x 1.9 inch (WxHxD)
Approvals / marking
0832-CPD-0866
P31.311.810 - 5en / 01.14
G 201033
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 5 - 40
Product Sheet | Detecon
Standard detectors
Modules, addressable, wall mounting
Input/output module IOX 847 W-I
Order no.: 905400
Analog addressable input/output module for monitoring a dry
contact including line monitoring and additional opto-isolator
input, and for controlling an output via a relay.
In the wall-mounted installation version.
The states "quiescent", "alarm" and "fault" are recognised.
Applicable for operation in ¿re alarm panels with Loop AP
protocol.
Addressing via DIP switches; the address can also be
modi¿ed after installation.
The electronics features an integrated isolator; a fault, short
circuit or open line is indicated.
Inputs
Outputs
: 2 (of which 1 opto-isolator)
: 1
Connection / mounting
Technical specifications
Operating voltage
Quiescent current at 24 V DC:
Min. (quiescent)
Max (short circuit input,
LED on)
Indication of closed input
17 V - 28 V DC
1.25 mA
3.6 mA
red LED
Active output indication
red LED
Fault indication
2 yellow LEDs
Integrated isolator
yes
-20 °C to +70 °C
(-4 °F to +158 °F)
IP 54
Operating temperature
IP rating (EN 60529)
Technology / protocol
Relative humidity
(IEC721-3-3)
Speci¿cation according to
Weight
Dimensions
Loop AP / XP95
0 to 95%
no condensation
CEA GEI 1-052 (6/97)
240 g (0.5 lbs)
150 x 90 x 48 mm (WxHxD)
5.9 x 3.5 x 1.9 inch (WxHxD)
Connection cable
2-lead
Recommended cable, standard
747180
J-Y(ST)Y-2x2x0.8 mm
Conductor cross-section max. 1.5 mm2 (0.002 square inch)
Electrostatic shielding
not required
Contact input:
Voltage at contact input
Cable resistance max.
Terminating resistor
Pre-alarm resistance
Main alarm resistance
9 - 11 V DC
50 Ohm
20 kOhm
10 kOhm
1 kOhm
Opto-isolator input:
Voltage range
Impedance
max. 35 V DC
10 kOhm
Relay output:
Voltage
Current
max. 30 V DC
max. 1 A DC
Approvals / marking
0832-CPD-0869
P31.311.810 - 7en / 01.14
G 201032
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 5 - 41
Product Sheet | Detecon
Standard detectors
Modules, addressable, wall mounting
Input/output module IOX 875 W-I AC
Order no.: 905561
Analog addressable input/output module for monitoring a dry
contact including line monitoring and for controlling an output
via a relay (230 V AC switchable).
In the version for wall-mounted installation (W).
The inputs can recognise the states "quiescent", "alarm" and
"fault".
Applicable for operation in ¿re alarm panels with Loop AP
protocol.
Addressing via DIP switches; the address can also be
modi¿ed after installation.
Inputs
Outputs
: 1
: 1
Connection / mounting
Technical specifications
Operating voltage
Quiescent current at 24 V DC:
Min. (quiescent)
Max (relay activated and
LEDs on)
Indication of closed input
Active output indication
Fault indication
Integrated isolator
Operating temperature
IP rating (EN 60529)
Technology / protocol
Relative humidity
(IEC721-3-3)
Weight
Dimensions
17 V - 28 V DC
1.2 mA
3.5 mA
red LED
red LED
yellow LED
no
-20 °C to +70 °C
(-4 °F to +158 °F)
IP 54
Loop AP / XP95
0 to 95%
no condensation
240 g (0.5 lbs)
150 x 90 x 48 mm (WxHxD)
5.9 x 3.5 x 1.9 inch (WxHxD)
Connection cable
2-lead
Recommended cable, standard
747180
J-Y(ST)Y-2x2x0.8 mm
Conductor cross-section max. 1.5 mm2 (0.002 square inch)
Electrostatic shielding
not required
Contact input:
Voltage at contact input
Cable resistance max.
Terminating resistor
Main alarm resistance
Relay output:
Voltage
Current
9 - 11 V DC
50 Ohm
20 kOhm
470 Ohm
max. 48 V DC / 250 V AC
max. 2 A DC / 5 A AC
Approvals / marking
P31.311.810 - 8en / 01.14
0832-CPD-0860
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 5 - 42
Product Sheet | Detecon
Standard detectors
Modules, addressable, wall mounting
Input/output module IOX 588 W-I
Order no.: 905557
Analog addressable input/output module for monitoring dry
contacts including line monitoring and for controlling outputs
via relays.
Version for Àush-mounted wall installation (W).
The inputs can recognise the states "quiescent", "alarm" and
"fault".
Applicable for operation in ¿re alarm panels with Loop AP
protocol.
Addressing via DIP switches; the address can also be
modi¿ed after installation.
The electronics features an integrated isolator; a fault, short
circuit or open line is indicated.
Inputs
Outputs
: 3
: 3
Connection / mounting
Technical specifications
Operating voltage
Quiescent current at 24 V DC:
Min. (quiescent)
Max (all relays activated and
LEDs o)
Indication of closed input
17 V - 28 V DC
3.0 mA
7.5 mA
3 red LEDs
Active output indication
3 red LEDs
Fault indication input
3 yellow LEDs
Fault indication isolator
yellow LED
Integrated isolator
yes
-20 °C to +70 °C
(-4 °F to +158 °F)
IP 54
Operating temperature
IP rating (EN 60529)
Technology / protocol
Relative humidity
(IEC721-3-3)
Speci¿cation according to
Weight
Dimensions
Connection cable
2-lead
Recommended cable, standard
747180
J-Y(ST)Y-2x2x0.8 mm
Conductor cross-section max. 1.5 mm2 (0.002 square inch)
Electrostatic shielding
not required
Contact input:
Voltage at contact input
Cable resistance max.
Terminating resistor
Main alarm resistance
9 - 11 V DC
50 Ohm
20 kOhm
4.7 kOhm
Relay output:
Voltage
Current
max. 30 V DC
max. 1 A DC
Loop AP / XP95
0 to 95%
no condensation
CEA GEI 1-052 (6/97)
621 g (1.4 lbs)
250 x 175 x 75 mm (WxHxD)
9.8 x 6.9 x 3 inch (WxHxD)
Approvals / marking
0832-CPD-0864
P31.311.810 - 9en / 01.14
G 202052
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 5 - 43
Product Sheet | Detecon
Standard detectors
Modules, addressable, wall mounting
Output module OUX 849 W-I
Order no.: 905401
Analog addressable output module for controlling a dry
contact.
Flush-mounted wall-mounted installation (W).
Applicable for operation in ¿re alarm panels with Loop AP
protocol.
Addressing via DIP switches; the address can also be
modi¿ed after installation.
The electronics features an integrated isolator; a fault,
short circuit or open line is indicated.
Inputs
Outputs
: 0
: 1
Connection / mounting
Technical specifications
Operating voltage
Quiescent current at 24 V DC:
Min. (quiescent)
Max (relay activated
and LEDs on)
Alarm indication
17 V - 28 V DC
1.25 mA
3.6 mA
red LED
Fault indication
yellow LED
Integrated isolator
yes
-20 °C to +70 °C
(-4 °F to +158 °F)
IP 54
Operating temperature
IP rating (EN 60529)
Technology / protocol
Relative humidity
(IEC721-3-3)
Speci¿cation according to
Weight
Dimensions
Connection cable
2-lead
Recommended cable, standard
747180
J-Y(ST)Y-2x2x0.8 mm
Conductor cross-section max. 1.5 mm2 (0.002 square inch)
Electrostatic shielding
not required
Relay output:
Voltage
Current
max. 30 V DC
max. 1 A DC
Loop AP / XP95
0 to 95%
no condensation
CEA GEI 1-052 (6/97)
240 g (0.5 lbs)
150 x 90 x 48 mm (WxHxD)
5.9 x 3.5 x 1.9 inch (WxHxD)
Approvals / marking
0832-CPD-0870
P31.311.810 - 13en / 01.14
G 201032
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 5 - 44
Product Sheet | Detecon
Standard detectors
Modules, addressable, wall mounting
Sounder control module SCX 852 W-I
Order no.: 905560
Analog addressable sounder control module for controlling
sounders in continuous or pulse-controlled operation with
additional contact input for monitoring the external power
supply of the sounders.
Flush-mount wall installation type (W).
Applicable for operation in ¿re alarm panels with Loop AP
protocol.
Addressing via DIP switches; the address can also be
modi¿ed after installation.
The electronics features an integrated isolator; a fault,
short circuit or open line is indicated.
Inputs
Outputs
: 1 (contact input)
: 1
Connection / mounting
Technical specifications
Operating voltage
Quiescent current at 24 V DC:
Min. (quiescent)
Max (relay activated
and LEDs on)
Alarm indication
17 V - 28 V DC
1.25 mA
1.5 mA
red LED
Fault indication
2 yellow LEDs
Integrated isolator
yes
-20 °C to +70 °C
(-4 °F to +158 °F)
IP 54
Operating temperature
IP rating (EN 60529)
Technology / protocol
Relative humidity
(IEC721-3-3)
Speci¿cation according to
Weight
Dimensions
Connection cable
2-lead
Recommended cable, standard
747180
J-Y(ST)Y-2x2x0.8 mm
Conductor cross-section max. 1.5 mm2 (0.002 square inch)
Electrostatic shielding
not required
External power supply
Contact input
9 - 50 V DC
NC/NO contact
Relay output:
Voltage
Current
max. 30 V DC
max. 1 A DC
Loop AP / XP95
0 to 95%
no condensation
CEA GEI 1-052 (6/97)
240 g (0.5 lbs)
150 x 90 x 48 mm (WxHxD)
5.9 x 3.5 x 1.9 inch (WxHxD)
Approvals / marking
0832-CPD-0871
P31.311.810 - 15en / 01.14
G 201095
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 5 - 45
Product Sheet | Detecon
Standard detectors
Modules, addressable, wall mounting
Conventional zone module ZMX 845 W-I
Order no.: 905804
Analog addressable module for monitoring a conventional
zone. Automatic detectors and manual call points using
conventional technology can be connected.
Flush-mount wall installation type (W).
The states "quiescent", "alarm" and "fault" are recognised.
Applicable for operation in ¿re alarm panels with Loop AP
protocol.
Addressing via DIP switches; the address can also be
modi¿ed after installation.
The electronics features an integrated isolator; a fault,
short circuit or open line is indicated.
Inputs
Outputs
: 1 (conventional zone)
: 0
Connection / mounting
Technical specifications
Operating voltage
Voltage output
Limit value zone
Quiescent current at 24 V DC:
Min. (quiescent)
Max (alarm event)
Zone alarm indication
17 V - 28 V DC
19 V DC or
Operating voltage - 1,5 V
4.0 mA + detector
19.0 mA + detector
red LED
Fault indication
yellow LED
Integrated isolator
yes
-20 °C to +70 °C
(-4 °F to +158 °F)
IP 54
Operating temperature
IP rating (EN 60529)
Technology / protocol
Relative humidity
(IEC721-3-3)
Weight
Dimensions
Connection cable
2-lead
Recommended cable, standard
747180
J-Y(ST)Y-2x2x0.8 mm
Conductor cross-section max. 1.5 mm2 (0.002 square inch)
Electrostatic shielding
not required
Limit value zone:
Voltage
Cable capacity
Terminating resistor
19 V DC or
Operating voltage - 1.5 V
max. 50 ȝF
5.1 kOhm
Loop AP / XP95
0 to 95%
no condensation
230 g (0.5 lbs)
250 x 175 x 75 mm (WxHxD)
9.8 x 6.9 x 3 inch (WxHxD)
Approvals / marking
0832-CPD-0868
P31.311.810 - 16en / 01.14
G 201094
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 5 - 46
Product Sheet | Detecon
Standard detectors
Modules, addressable, wall mounting
FMZ5000 loop coupler
Order no.: 908131
The loop coupler consists of a loop coupler module, Order
no.: 902954, which is mounted in a Àushmount wall enclosure
with IP 65 protection rating. According to DIN VDE 0833-2,
Section 6.2.5, no more than the following may be connected
to an FMZ 5000 loop coupler:
e.g. max. 1 detection range with max. 1600 m² (1913 square
yard) or 32 automatic detectors of a detection range or
10 manual call points of a detection range.
The only loop coupler module that may only be ¿tted outside
the ¿re alarm panel is the FMZ 5000 loop coupler.
Product features
Application
•
For the interface connection of limit monitors to a loop of
the loop module.
For the interface connection of industrial detectors in
conventional technology to a Loop AP.
•
The device has a loop coupler module.
•
Can be expanded by adding another loop coupler
module.
Technical specifications
Operating voltage
Quiescent current consumption
Current consumption,
2 modules
Line voltage, min
Alarm /
terminating resistor
Number of detectors per line
19 V - 28 V DC
approx. 20 mA
without line terminations
approx. 40 mA
without line terminations
9 - 19 V DC
470 Ohm /
1.8 kiloOhm
32
Technology / protocol
Number of loop coupler
modules
IP rating (EN 60529)
Conductor cross-section
Integrated isolator
Ambient temperature
Relative humidity
(IEC721-3-3)
Speci¿cation according to
Enclosure
Loop AP / XP95
1, expandable to 2
IP 65
2.5 mm (0.004 square inch)
2
no
-5 °C to +40 °C
(+23 °F to +104 °F)
0 to 95%
no condensation
CEA GEI 1-052 (6/97)
Included in delivery
Device completely assembled and ready for installation in the
area.
Supplementary sheet.
Not included in delivery
Mounting hardware, further cable glands.
Note
To install the device or an additional module the loop coupler
supplementary sheet, Order no.:908048, needs to be
observed.
transparent plastic
Installation position
P31.311.810 - 11en / 01.14
The FMZ 5000 loop coupler can be installed directly in the
monitoring area. The voltage supply can be provided via
the ¿re alarm panel or a separate power supply unit (in
accordance with EN54-4 A2). If more than 32 detectors are
connected, the power supply line must have a redundant
design.
To supply the conventional lines, the loop coupler module
requires an external 24 V DC power supply.
Weight
Dimensions
vertical
350 g (0.8 lbs)
187.5 x 250 x 175 mm (WxHxD)
7.4 x 9.8 x 6.9 inch (WxHxD)
Approvals / marking
G 209028
0786-CPD-20684
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 5 - 47
Product Sheet | Detecon
Standard detectors
Modules, addressable
SUX5000 AP monitoring module
Order no.: 906973
The SUX5000 AP is a monitoring module for the installation
of fault and alarm signal transmitters in two-wire loop
systems with individual identi¿cation.
It allows the individual addressing of dry contactors such as
pressure switches, limit switches, extinguishing agent level
sensors or temperature sensors, with plain text information to
the FMZ 5000 ¿re alarm system or Loop AP-compatible ¿re
alarm system.
Product features
•
•
•
•
Integration into the switching device to be monitored.
Monitored signal path.
Loop integration, addressing via DIP switch on module.
Special applications:
connection to external contact, connection of LEDs,
hardware fault signal suppression.
Included in delivery
1 packaging unit (5x)
SUX5000 AP monitoring module
Not included in delivery
Fault signal transmitter
Notes
Technical specifications
Operating voltage
17 V - 28 V DC
Rated voltage
24 V DC
Quiescent current
230 ȝA
Operating current
300 ȝA
Integrated isolator
no
-40 °C to +80 °C
(-40 °F to +176 °F)
Loop AP / XP95
0 to 93%
no condensation
4 g (0.01 lbs)
38.5 x 28.5 x 8 mm (WxHxD)
1.5 x 1.1 x 0.3 inch (WxHxD)
Operating temperature
Technology / protocol
Relative humidity
(IEC721-3-3)
Weight
Dimensions
The SUX5000 AP can be used in combination with the
following devices:
Universal card adapter SUX50
902698
Reed contact limit switch
886343
Float switch monitoring
879475
Float switch monitoring pump house
842358
Pressure switch PMÜ-3
792183
Pressure switch PMÜ-10
810564
Pressure switch PMA-3
116512
Approvals / marking
0786-CPD-20416
P31.311.810 - 17en / 01.14
G 208059
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 5 - 48
Product Sheet | Detecon
Standard detectors
Modules, conventional
Card LÖ leakage detector
Order no.: 800707
Monitoring card for connection of LKM2001 Àow detector to
FMZ 4100 and FMZ 5000 control units.
Connection / mounting
Connection cable
2-lead
Recommended cable, standard
747180
J-Y(ST)Y-2x2x0.8 mm
Conductor cross-section
max. 2.5 mm2 (0.004 square inch), solid conductor
max. 1.5 mm2 (0.002 square inch), strand with wire end
sleeve
Cable length
max. 700 m (0.43 miles), at Ø 0.8 mm
(0.03 inch) lead
Technical specifications
Number of leak detectors
per line
Operating temperature
Weight
Dimensions
max. 10
-20 °C to +60 °C
(-4 °F to +140 °F)
10 g (0.02 lbs)
28 x 28 mm (LxB)
1.1 x 1.1 inch (LxB)
Card MVA LÖ
Approvals / marking
Order no.: 782239
Module for monitoring the feed cable and the solenoid of a
solenoid valve for wire break and short circuit. The card is
integrated in the valve connection box. Monitoring and triggering must be carried out with a primary control group.
Connection / mounting
Connection cable
2-lead
Recommended cable, standard
747180
J-Y(ST)Y-2x2x0.8 mm
Conductor cross-section
max. 2.5 mm2 (0.004 square inch), dolid conductor
max. 1.5 mm2 (0.002 square inch), strand with wire end
sleeve
Technical specifications
P31.311.820en / 01.14
Input voltage:
- Triggering
- Monitoring
Ampacity
Rated capacity of the
solenoid valve at 24 V
Display, triggering
Operating temperature
Weight
Dimensions
17 V - 29 V DC
0 V - 10 V DC
max. 2 A
Approvals / marking
max. 38 W
1 LED red
-20 °C to +60 °C
(-4 °F to +140 °F)
10 g (0.02 lbs)
28 x 28 mm (LxB)
1.1 x 1.1 inch (LxB)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 5 - 49
Product Sheet | Detecon
Standard detectors
Modules, conventional
MVA LÖ redundant card
Order no.: 904585
Using the monitoring module the feed lines to the coil of a
solenoid valve or trigger magnets are monitored for discontinuity and short circuit and whether the coil is connected.
The module must be used for monitoring when a trigger element in a ¿re extinguishing system is responsible for several
extinguishing zones and therefore the control and the feed
lines have to be solved in a redundant design.
The module must be used within the connection housing of
the valve.
Connection / mounting
Recommended cable
2-lead
Conductor cross-section max. 2.5 mm2 (0.004 square inch),
solid conductor
max. 1.5 mm2 (0.002 square inch), Àexible wire with ferrule
Technical specifications
Input voltage
- Activation
- Monitoring
Current carrying capacity
Power rating of
solenoid valve at 24 V
Anzeige, Ansteuerung
Operating temperature
Weight
Dimensions
17 V - 29 V DC
0 V - 10 V DC
max. 2 A
Note
To monitor and control the triggering, two control groups of
two different control group modules must be used.
max. 38 W
1 LED red
-20 °C to + 50 °C
(-4 °F to +122 °F)
10 g (0.02 lbs)
28 x 28 mm (LxW)
1.1 x 1.1 inch (LxW)
Card module Sounder
Approvals / marking
Order no.: 782240
Module for monitoring the feed cable of an optical and acoustic alarm device for wire break and short circuit. The card
must be installed into the housing of each alarm device.
Connection / mounting
Connection cable
2-lead
Recommended cable, standard
747180
J-Y(ST)Y-2x2x0.8 mm
Conductor cross-section
max. 2.5 mm2 (0.004 square inch), solid conductor
max. 1.5 mm2 (0.002 square inch), strand with wire end
sleeve
P31.311.820en / 01.14
Technical specifications
Input voltage:
- Triggering
- Monitoring
Ampacity
Operating temperature
Weight
Dimensions
Approvals / marking
19 V - 29 V DC
0 V - 10 V DC
max. 0.5 A
-20 °C to +60 °C
(-4 °F to +140 °F)
20 g (0.04 lbs)
80 x 40 mm (LxB)
3.2 x 1.6 inch (LxB)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 5 - 50
Product Sheet | Detecon
Standard detectors
Modules, conventional
Card MVA impulse
Order no.: 800112
Module for monitoring the feed cable and the solenoid of a
2/2-way solenoid valve of the impulse type for wire break and
short circuit. The „NC solenoid“ is also connected to the card.
The card is integrated in the valve connection box. Monitoring
and triggering must be carried out with a primary control
group.
Connection / mounting
Connection cable
3-lead
Recommended cable, standard
747180
J-Y(ST)Y-2x2x0.8 mm
Conductor cross-section
max. 2.5 mm2 (0.004 square inch), solid conductor
max. 1.5 mm2 (0.002 square inch), strand with wire end
sleeve
Technical specifications
Input voltage:
- Triggering
- Monitoring
Ampacity
Display, triggering
Operating temperature
Weight
Approvals / marking
1 LED red
-20 °C to +60 °C
(-4 °F to +140 °F)
10 g (0.02 lbs)
28 x 28 mm (LxB)
1.1 x 1.1 inch (LxB)
P31.311.820en / 01.14
Dimensions
19 V - 29 V DC
0 V - 10 V DC
max. 2 A
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 5 - 51
Product Sheet | Detecon
Standard detectors
Test equipment
Multifunction tester S1000
Smoke & heat detector
Order no.: 908595
Product features
•
Generation of smoke and heat during one only test.
•
Easier and speedier maintenance procedure.
•
Used for optical smoke detectors, ionisation smoke
detectors and heat detectors (differential and maximum
detectors).
•
Reduction of testing periods.
•
Increased testing capacity of the smoke capsules.
•
Automatic infrared identi¿cation of the detector.
•
Colour code LED for feedback to the operator.
•
Top adjustable in several positions.
•
Optimised method for smoke generation.
The multistimulus detector tester S1000 is intended for the
functional testing of point-type ¿re detectors with single or
multiple sensors. As the test of different detector types can
be conducted with one test tool, it is no longer necessary to
switch between several test tools. The substances releasing
smoke and heat are generated in the test tool. The test tool
is suitable for all optical smoke detectors, ionization detectors
and heat detectors (differential and maximum detectors).
The test of the different sensors can be conducted either
individually, successively or simultaneously for all of them at
once. The required stimulus in each case is generated at the
time of the test from the corresponding smoke capsule. The
multilingual selection of the testing stimuli, as well as their
combination and sequence is menu-driven via the navigation
keys and displayed on the screen. Compared to the areosol
cans the smoke capsule offers higher test capacities.
Included in delivery
1 smoke and heat detector tester head unit only
1 smoke capsule
Note
Only heat detectors with a release temperature of up to 60 °C
(140 °F) can be tested.
Approvals / marking
Technical specifications
IP rating
Working temperature
Storage temperature
Relative humidity
(IEC721-3-3)
Weight
P31.311.911en / 01.14
Dimensions
IP 20
+5 °C to +45 °C
(+41 °F to +113 °F)
-10 °C to +50 °C
(+14 °F to +122 °F)
0 to 85 %,
no condensation
750 g (1.7 lbs)
153 x 397 mm (WxH)
6 x 15.6 inch (WxH)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 5 - 52
Product Sheet | Detecon
Standard detectors
Test equipment
Multifunction test set S1001
Smoke & heat detector
Order no.: 908596
Product features
•
Generation of smoke and heat during one only test run.
•
Easier and speedier maintenance procedure.
•
Used for optical smoke detectors, ionisation smoke
detectors and heat detectors (differential and maximum
detector).
•
Reduction of testing periods.
•
Increased testing capacity of the smoke capsules.
•
Automatic infrared identi¿cation of the detector.
•
Colour code LED for feedback to the operator.
•
Top adjustable in several positions.
•
Optimised method for smoke generation.
The multistimulus detector tester kit S1001 is intended for
the functional testing of point-type ¿re detectors with single
or multiple sensors. As the test of different detector types can
be conducted with one test tool, it is no longer necessary to
switch between several test tools. The substances releasing
smoke and heat are generated in the test tool. The test tool
is suitable for all optical smoke detectors, ionization detectors
and heat detectors (differential and maximum detectors).
The test of the different sensors can be conducted either
individually, successively or simultaneously for all of them at
once. The required stimulus in each case is generated at the
time of the test from the corresponding smoke capsule. The
multilingual selection of the testing stimuli, as well as their
combination and sequence is menu-driven via the navigation
keys and displayed on the screen. Compared to the areosol
cans the smoke capsule offers higher test capacities.
Included in delivery
1 smoke and heat detector tester head unit only
1 smoke capsule
2 NiMH battery packs
1 rapid charger 220/240 V AC; 12 V DC
Note
Only heat detectors with a release temperature of up to 60 °C
(140 °F) are testable.
Approvals / marking
Technical specifications
Battery charging time
Battery baton
IP rating
Working temperature
Storage temperature
Relative humidity
(IEC721-3-3)
Weight
7.2 V 2.2 Ah NiMH
IP 20
+5 °C to +45 °C
(+41 °F to +113 °F)
-10 °C to +50 °C
(+14 °F to +122 °F)
0 to 85 %,
no condensation
1250 g (2.8 lbs)
153 x 397 mm (WxH)
6 x 15.4 inch (WxH)
P31.311.911en / 01.14
Dimensions
75 - 90 min.
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 5 - 53
Product Sheet | Detecon
Standard detectors
Test equipment
Smoke detector test kit S834
Order no.: 906947
The universal device kit with extendable ¿breglass poles for
testing smoke detectors up to a height of approx. 6 m
(374 inch).
The smoke detector testing device can be used with the
SA3 aerosol for all smoke detectors. The swivel frame also
facilitates the testing of detectors that are dif¿cult to access.
The test aerosol is released by touch, with a patented
membrane allowing the ef¿cient use of the aerosol.
The aerosol is designed for use with the smoke detector
testing device to test ionisation and optical smoke detectors.
Features of the aerosol include reliable test triggering of
the detectors, residue-free use, rapid clearing and low
consumption.
Product features
Included in delivery
•
Universal gripper for removing / mounting detectors.
•
Telescopic poles for working heights of up to 6 m
(374 inch).
1 telescopic pole 4.5 m (177.16 inch)
1 smoke detector testing device
2 carrying bags
•
Smoke detector tester for optical and ionisation smoke
detectors.
Technical specifications
approx. 6 m (236 inch)
+10 °C to +35 °C
Working temperature
(+50 °F to +95 °F)
- 10 °C to +50 °C
Storage temperature
(+14 °F to +122 °F)
Weight
2210 g (4.9 lbs)
100 x 1290 mm (dia. x L)
Size of bag for telescopic poles
3.93 x 50.78 inch (dia. x L)
510 x 440 x 270 mm (WxHxD)
Size of device bag
20.1 x 17.3 x 10.6 inch (WxHxD)
P31.311.911en / 01.14
Max. working height
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 5 - 54
Product Sheet | Detecon
Standard detectors
Test equipment
Smoke detector test kit S811
Product features
•
Universal gripper for removing / mounting detectors.
•
Telescopic poles for working heights of up to 6 m
(374 inch).
•
Smoke detector tester for optical and ionisation smoke
detectors.
Technical specifications
Adjustment range
of three-point gripper
Max. working height
Working temperature
Storage temperature
Weight
Size of bag for telescopic poles
The universal device kit includes everything needed for
removing, inserting and testing smoke detectors.
Extendable ¿breglass poles are for testing and installing
detectors up to a height of approx. 6 m.
By adjusting the three-point gripper a six-stage division for
different detector diameters is possible.
The smoke detector testing device can be used with the
SA3 aerosol for all smoke detectors. The swivel frame also
facilitates the testing of detectors that are dif¿cult to access.
The test aerosol is released by touch, with a patented
membrane allowing the ef¿cient use of the aerosol.
The aerosol is designed for use with the smoke detector
testing device to test ionisation and optical smoke detectors.
Features of the aerosol include reliable test triggering of
the detectors, residue-free use, rapid clearing and low
consumption.
Included in delivery
1 telescopic pole 4.5 m (177.16 inch)
1 detector removal tool
1 smoke detector testing device
2 carrying bags
P31.311.911en / 01.14
Size of device bag
65 mm to 110 mm
(2.56 inch to 4.33 inch)
approx. 6 m (236.22 inch)
+10 °C to +45 °C
(+50 °F to +95 °F)
-10 °C to +50 °C
(+14 °F to +122°F)
3310 g (7.3 lbs)
100 x 1290 mm (dia. x L)
3.93 x 50.78 inch (dia. x L)
510 x 440 x 270 mm (WxHxD)
20.1 x 17.3 x 10.6 inch
(WxHxD)
Order no.: 906946
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 5 - 55
Product Sheet | Detecon
Standard detectors
Test equipment
Heat detector test kit S461
Order no.: 901340
Fully automated, battery-operated heat detector testing
device.
Easy to use and energy-saving thanks to activation of the
heating process when the testing device is placed on the
detector.
The detector test is carried out completely Àame-free through
the use of a warm stream of air horizontal to the testing head
cup. This stream of air comes into direct contact with the
sensor chamber, allowing the detector's alarm to be triggered
rapidly and in a reproducible manner.
Product features
Included in delivery
•
Heat radiation without an open Àame.
•
Battery operated.
•
Rapid battery charger for 230V AC or 12V DC on-board
power supply.
1 heat detector testing device
2 batteries
1 rapid charger 220/240 V AC; 12 V DC
•
Red and green LEDs for testing status indication.
•
Testing time limit of max. 120 seconds.
•
Internal fan cools down heating element.
•
Energy ef¿ciency mode, automatic shutdown after
5 minutes of inactivity.
Technical specifications
Capacity
50 tests, 30 seconds each
Rapid battery charge
Working temperature
Storage temperature
Relative humidity
(IEC721-3-3)
Weight
P31.311.911en / 01.14
Dimensions
75 - 90 minutes
+5 °C to +45 °C
(+41 °F to +113 °F)
-10 °C to +50 °C
(+14 °F to +122 °F)
0 to 85 %,
no condensation
1100 g (2.4 lbs)
135 x 330 mm (dia. x L)
5.3 x 13 inch (dia. x L)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 5 - 56
Product Sheet | Detecon
Standard detectors
Test equipment
Smoke & heat detector test kit S823
Product features
•
Universal gripper for removing / mounting detectors.
•
Heat detector test, battery-operated, without an open
Àame.
•
Telescopic poles for working heights of up to 9.3 m
(366 inch).
•
Smoke detector tester for optical and ionisation smoke
detectors.
Technical specifications
Adjustment range
of three-point gripper
Dimensions of heat detector
tester
Capacity heat detector tester
Rapid battery charge
65 mm to 110 mm
(2.56 inch to 4.33 inch)
135 x 330 mm (dia. x L)
5.3 x 13 inch (dia. x L)
50 tests, 30 seconds each
75 - 90 minutes
Order no.: 906948
The complete device kit includes everything needed for
removing, replacing and testing smoke and heat detectors.
Extendable ¿breglass poles are for testing and installing
detectors up to a height of approx. 9,3 m (366 inch).
By adjusting the three-point gripper a six-stage division for
different detector diameters is possible.
The detector test is carried out completely Àame-free through
the use of a warm stream of air horizontal to the testing head
cup. This stream of air comes into direct contact with the
sensor chamber, allowing the detector's alarm to be triggered
rapidly and in a reproducible manner.
The smoke detector testing device can be used with the
SA3 aerosol for all smoke detectors. The test aerosol is
released by touch, with a patented membrane allowing the
ef¿cient use of the aerosol.
The aerosol is designed for use with the smoke detector
testing device to test ionisation and optical smoke detectors.
Features of the aerosol include reliable test triggering of
the detectors, residue-free use, rapid clearing and low
consumption.
Included in delivery
3 telescopic poles 1.1 m (43.30 inch)
1 telescopic pole 4.5 m (177.16 inch)
1 detector removal tool
1 smoke detector testing device
1 heat detector testing device
2 batteries
1 rapid charger 220/240 V AC; 12 V DC
2 carrying bags
approx. 9.3 m (366 inch)
+10 °C to +35 °C
Working temperature
(+50 °F to +95 °F)
-10 °C to +50 °C
Storage temperature
(+14 °F to +122 °F)
Relative humidity
0 to 85 %,
(IEC721-3-3)
no condensation
Weight
3300 g (7.3 lbs)
100 x 1290 mm (dia. x L)
Size of bag for telescopic poles
3.93 x 50.78 inch (dia. x L)
510 x 440 x 270 mm (WxHxD)
Size of device bag
20.1 x 17.3 x 10.6 inch (WxHxD)
P31.311.911en / 01.14
Max. working height
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 5 - 57
Product Sheet | Detecon
Standard detectors
Test equipment
Test clamp WMX D
Order no.: 719857
Function test of differential/maximum heat detectors of open
design (WMX type D).
Note
This procedure is a substit for a coarse heat test, as the
release resistance is adapted to the speci¿c type and a
detector would not respond if the heat detector or any other
important component is defective.
Not included in delivery
Pipe extension service devices
Technical specifications
Weight
P31.311.911en / 01.14
Dimensions
380 g (0.8 lbs)
75 x 118 x 85 mm (LxWxH)
3 x 4.7 x 3.4 inch (LxWxH)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 5 - 58
756549
Product Sheet | Detecon
Standard detectors
Test equipment, accessories
Telescopic pole 1.1 m (43 inch)
Order no.: 901344
Telescopic pole 2.5 m (98 inch)
Order no.: 906951
Telescopic pole 4.5 m (177 inch)
Order no.: 901345
Carrying bag for telescopic poles
Order no.: 906952
Detector removal tool
Order no.: 906955
Set of batteries
Order no.: 906954
Rapid charger 220/240 V AC, 12 V DC
Order no.: 906953
Silicone membrane for testing cup
Order no.: 906949
For S834, S811, S461 and S823
Aerosol retaining cup
Order no.: 906950
For S834, S811 and S823
Test aerosol SA3
Order no.: 905904
For S834, S811 and S823
Smoke capsule
Order no.: 908597
P31.311.914en / 02.13
For S1000 and S1001
Test fire mat type 1640
Order no.: 723014
Technical specifications
Operational test.
Material
Gaseous combustion products:
Carbon dioxide,
Carbon monoxide
Methane, Ethane
Propane, Ethylene
Propylene, Acetylen
Hydrochlorid acid,
Fluoride acid
Nitrous gases
Ammonia and Organic bases,
traces of Hydrocyamic acid
Weight
Dimensions
PU foam
1.55 Vol.%, 1.21 Vol.%
0.41 Vol.%, 0.02 Vol.%
0.01 Vol.%, 0.21 Vol.%
0.11 Vol.%, 0.03 Vol.%
not
0.035 mg/l
Not included in delivery
Base
e.g. aluminium foil
Note
Customers permission for burning the mat required. Aerosols
may effect electronic devices. Pollution of magnetic mass
storages.
0.16 mg/l
70 g (0.15 lbs)
500 x 400 x 20 mm (WxHxD)
19.68 x 15.74 x 0.78 inch
(WxHxD)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 5 - 59
Product Sheet | Detecon
Industrial detectors
Fire detectors for industrial risks
UniVario FMX5000 IR
3-channel infrared Àame detector with three-way optics test
for complete function monitoring. Very high responsivity
and ¿ltering of interfrence such as sunlight and hot surfaces
through intelligent evaluation algorithms
UniVario FMX5000 UV
Flame detector with spectral sensitivity in the ultraviolet
range. High response sensitivity with monitoring area
up to 676 m2. Interference such as cosmic radiation and
thunderstorms (lightning) is ¿ltered out intelligent evaluation
algorithms with integrated self-testing for monitoring the
functionality (optical test).
UniVario WMX5000
Heat detector with a robust stainless steel heat sensor.
A microcontroller monitors the functionality and analyses
data. The detector can be freely con¿gured for any
application. For this, response temperatures, response
classes and indices can be adjusted. Can be expanded by
adding an LCD display.
UniVario WMX5000 FS
Heat detector for heavy-duty daily use with a robust stainless
steel heat sensor rod or Àexible hose which protrudes
from the enclosure. Thermoelectric sensors for response
temperatures up to 850 °C (1562 °F). A microcontroller
monitors the functionality and analyses data. Prominent
response temperatures and all response classes can be
freely con¿gured, along with rate-of-rise and static (¿xed
temperature) response behaviour. Can be expanded by
adding an LCD display.
UniVario
A family of industrial ¿re detectors based on a uniform platform. Highly variable, with a modular system for maximum
adaptability.
P31.312.000en / 02.14
Conventional detectors are available and can be changed to analog addressable detectors by adding the communication
module KMX5000 AP / KMX5000 AP Ex.
To achieve the best possible protection in each individual scenario, ¿re detectors of different designs and response sensitivity
are used according to the requirements of each protected site. They work indoors and outdoors; in the direct vicinity of the
protected site like UniVario WMX5000, or from further a¿eld like UniVario FMX5000 UV; in clean room environments as well as
in extremely dirty process conditions. Equipped internally with the very latest advanced technology, they also feature a robust
and attractive enclosure design. This new generation of high-tech ¿re detectors is substantially prefabricated, is easy and quick
to install and can be easily integrated into existing solutions, making them an affordable alternative to conventional systems.
One major advantage of the new range is their ability to forward detector data to databases for the purposes of analysis,
maintenance or statistics compilation.
Variations of UniVario detectors for conventional lines or analogue addressable systems are available, well graded for different
hazard areas. The UniVario detector series with state of the art technology has big advantages due to lower installation costs in
analogue addressable systems and increased safety due to permanent data transfer between control panel and detectors.
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 6 - 1
Product Sheet | Detecon
Industrial detectors
Fire detectors for industrial risks
Overview accessories UniVario
Bracket
Console
Base
Base 3M16
Base LCD
Base+Isolator
Relay module
Comms module Service device
F
FMX5000 IR
FMX5000 IR HR
Base
HR
Bracket
HR
F
FMX5000 UV
FMX5000 UVs
F
W
WMX5000
WMX5000 FS
WMX5000 FS Flex
WMX5000 single hole
W
W
F
P31.312.000en / 02.14
WMX5000 VA
W
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 6 - 2
Product Sheet | Detecon
Industrial detectors
Fire detectors for industrial risks
Overview accessories UniVario
Ex barrier
Bracket
Console
Base
Base Ex
Comms Comms Service
module module Ex device
3GD
F
FMX5000 IR 3GD
*1
2G1D
F
FMX5000 IR Ex
3GD
FMX5000 UV 3GD
F
*1
P31.312.000en / 02.14
*1) The service device should only be used outside of the explosion hazardous zone
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 6 - 3
Product Sheet | Detecon
Industrial detectors
Fire detectors for industrial risks
Overview accessories UniVario
Ex barrier
Bracket
Console
Base
Base Ex
Comms Comms Service
module module Ex device
3GD
W
WMX5000 3GD
*1
2G1D
W
WMX5000 Ex
3GD
W
WMX5000 FS 3GD
*1
2G1D
W
WMX5000 FS Ex
3GD
W
WMX5000 FS Flex 3GD
*1
2G1D
W
WMX5000 FS Flex Ex
3GD
WMX5000 single hole 3GD
W
*1
2G1D
WMX5000 single hole Ex
W
P31.312.000en / 02.14
*1) The service device should only be used outside of the explosion hazardous zone
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 6 - 4
Product Sheet | Detecon
Industrial detectors
UniVario IR flame detector
FMX5000 IR
Order no.: 907481
Triple IR Àame detector for the detection of typical ¿res. Including 3 channel optic test monitoring all functional characteristics of detector.
Designed for use in rough industrial environments.
Equipped for operation as a conventional detector.
Expansion to a detector with Loop AP protocol via KMX5000 AP
communication module.
Product features
Optional accessories
•
Highly reliable against false alarms, e.g. from hot surfaces or sunlight.
•
A microcontroller monitors the functionality and analyses
the recorded data. Faults can be indicated on the
detector or on a separate line.
Parallel indicator LMX5000
Weather protection MX5000 complete
KMX5000 AP communication module
Silicone-free design
•
Service interface, history memory.
•
Connection of remote indicator possible.
•
3-channel optic test.
908499
910134
905883
Not included in delivery
Base UniVario MX5000
Bracket MX5000
Terminating resistor 1.8 K / 0.5 W
904701
904757
675235
Connection / mounting
Technical specifications
Detection method
Sensitivity class
Viewing angle
1
90°
Operating voltage
7.6 V - 30 V DC
Quiescent current
2.3 mA
Alarm current
Alarm indication
Fault indication current
Fault indication
Operating temperature
IP rating (EN 60529)
Enclosure material
Relative humidity
(IEC721-3-3)
Speci¿cation according to
P31.312.330 - 1en / 02.13
3 IR Sensors
Weight
Dimensions
Connection cable standard detector
2-lead
Additional fault line connection
2-lead
External indication
2-lead
Recommended cable
JY (St) Y 2x2x0.8 mm (0.03 inch)
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Approvals / marking
G 209141
0786-CPD-20784
approx. 15 mA
1 LED red
approx. 15 mA
1 LED yellow
-20 °C to +80 °C
(-4 °F to +176 °F)
IP 67
Diecast aluminium
0 to 95%
no condensation
EN 54 Part 10
820 g (1.8 lbs)
100 x 50 mm (dia. x H)
3.9 x 2 inch (dia. x H)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 6 - 5
Product Sheet | Detecon
Industrial detectors
UniVario IR flame detector
FMX5000 IR HR
Art.-Nr.: 909404
Triple IR Àame detector for the detection of typical ¿res. Including 3 channel optic test monitoring all functional characteristics of detector.
Variante HR (high ressistance) designed for use in highly
rough industrial environments such as chemical industry.
Designed for operation as a conventional detector.
Expansion to a detector with Loop AP protocol via KMX5000 AP
communication module.
Product features
Optional accessories
•
Highly reliable against false alarms, e.g. from hot surfaces or sunlight
•
A microcontroller monitors the functionality and analyses
the recorded data. Faults can be indicated on the
detector or on a separate line
Parallel indicator LMX5000
Weather protection MX5000 complete
KMX5000 AP communication module
Silicone-free design
•
Service interface, history memory
•
Connection of remote indicator possible
•
3-channel optic test
Sensitivity class
Viewing angle
Operating voltage
Quiescent current
Alarm current
Alarm indication
Fault indication current
Fault indication
Operating temperature
IP rating (EN 60529)
P31.312.330 - 2en / 02.13
Enclosure material
Relative humidity
(IEC721-3-3)
Speci¿cation according to
Weight
Dimensions
Not included in delivery
Base UniVario MX5000 HR
Bracket MX5000
Mounting device bracked MX5000 HR
Terminating resistor 1.8 K / 0.5 W
909406
904757
909359
675235
Connection / mounting
Technical specifications
Detection method
908499
910134
905883
3 IR Sensors
1
90°
7.6 V - 30 V DC
2.3 mA
Connection cable standard detector
2-lead
Additional fault line connection
2-lead
External indication
2-lead
Recommended cable
JY (St) Y 2x2x0.8 mm (0.03 inch)
Approvals / marking
G 209141
0786-CPD-20784
approx. 15 mA
1 LED red
approx. 15 mA
1 LED yellow
-20 °C to +80 °C
(-4 °F to +176 °F)
IP 67
Diecast aluminium
0 to 95%
no condensation
EN 54 Part 10
820 g (1.8 lbs)
100 x 50 mm (dia. x H)
3.9 x 2 inch (dia. x H)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 6 - 6
Product Sheet | Detecon
Industrial detectors
UniVario UV flame detector
FMX5000 UV
Order no.: 904702
UV Àame detector for the detection of typical ¿res.
Including UV optic test monitoring all functional
characteristics of detector.
Designed for use in rough industrial environments.
Designed for operation as a conventional detector.
Expansion to a detector with Loop AP protocol via KMX5000 AP
communication module.
Product features
Optional accessories
•
Parallel indicator
Weather protection MX5000 complete
KMX5000 AP communication module
Silicone-free design
•
•
•
Highly reliable against false alarms, e.g. from lightning
Àashes or strong sunlight.
A microcontroller monitors the functionality and analyses
the recorded data. Faults can be indicated on the
detector or on a separate line.
Service interface, history memory.
Connection of remote indicator possible.
Technical specifications
Detection method
Sensitivity class
Viewing angle
UV sensor
1
90°
Operating voltage
7.6 V - 30 V DC
Quiescent current
approx. 0.25 mA
Alarm current
Alarm indication
Fault indication current
Fault indication
Operating temperature
IP rating (EN 60529)
Enclosure material
Relative humidity
(IEC721-3-3)
Speci¿cation according to
Weight
Not included in delivery
Base UniVario MX5000
Bracket MX5000
Terminating resistor 1.8 K / 0.5 W
Connection cable standard detector
2-lead
Additional fault line connection
2-lead
External indication
2-lead
Recommended cable
JY (St) Y 2x2x0.8 mm (0.03 inch)
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Approvals / marking
1 red LED
approx. 15 mA
904701
904757
675235
Connection / mounting
G 206132
0786-CPD-20286
1 yellow LED
-20 °C to +80 °C
(-4 °F to +176 °F)
IP 67
Diecast aluminium
0 to 95%
no condensation
EN 54 Part 10
820 g (1.8 lbs)
100 x 50 mm (dia. x H)
3.9 x 2 inch (dia. x H)
P31.312.310en / 02.13
Dimensions
approx. 15 mA
908499
910134
905883
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 6 - 7
Product Sheet | Detecon
Industrial detectors
UniVario UV flame detector
FMX5000 UVs
Order no.: 907375
UV Àame detector for the detection of typical ¿res.
Designed for use in rough industrial environments.
Designed for operation as a conventional detector.
Expansion for a detector with Loop AP protocol via KMX5000 AP
communication module.
Product features
Optional accessories
•
Parallel indicator
Weather protection MX5000 complete
KMX5000 AP communication module
Silicone-free design
•
•
•
Highly reliable against false alarms, e.g. from lightning
Àashes or strong sunlight.
A microcontroller monitors the functionality and analyses
the recorded data. Faults can be indicated on the
detector or on a separate line.
Service interface, history memory.
Connection of external signal indication possible.
Technical specifications
Detection method
Sensitivity class
Viewing angle
UV sensor
1
90°
Operating voltage
7.6 V - 30 V DC
Quiescent current
approx. 0.25 mA
Alarm current
Alarm indication
Fault indication current
Fault indication
Operating temperature
IP rating (EN 60529)
Enclosure material
Relative humidity
(IEC721-3-3)
Speci¿cation according to
Weight
1 red LED
approx. 15 mA
Not included in delivery
Base UniVario MX5000
Bracket MX5000
Terminating resistor 1.8 K / 0.5 W
904701
904757
675235
Connection / mounting
Connection cable standard detector
2-lead
Additional fault line connection
2-lead
External indication
2-lead
Recommended cable
JY (St) Y 2x2x0.8 mm (0.03 inch)
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Approvals / marking
G 206132
0786-CPD-20286
1 yellow LED
-20 °C to +80 °C
(-4 °F to +176 °F)
IP 67
Diecast aluminium
0 to 95%
No condensation
EN 54 Part 10
820 g (1.8 lbs)
100 x 50 mm (dia. x H)
3.9 x 2 inch (dia. x H)
P31.312.310en / 02.13
Dimensions
approx. 15 mA
908499
910134
905883
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 6 - 8
Product Sheet | Detecon
Industrial detectors
UniVario Heat detectors, standard
WMX5000
Order no.: 905441
The WMX5000 heat detectors are designed to detect open
¿res with rapid rise of temperature, e.g.:
– Flammable liquids and gases
– Highly Àammable plastics.
They are designed speci¿cally for operation in polluted
industrial environments, both indoors and outdoors. In
addition to static temperature detection, rapid rises in
temperature can also be registered by the rate-of-rise
method, for early ¿re detection.
Designed for operation as a conventional detector.
Expansion to a detector with Loop AP protocol via KMX5000 AP
communication module.
Product features
Optional accessories
•
Robust stainless steel heat sensor, resistant against
impact and vibration.
•
Freely con¿gurable response temperatures and classes in
accordance with EN54-5, along with rate-of-rise and static
responses. Con¿guration via DIP switches on the detector.
Detector remote indicator
Weather protection MX5000 complete
KMX5000 AP communication module
Silicone-free design
•
Service interface, history memory.
•
Connection of remote indicator possible.
Detection method
NTC sensor
Response classes
Operating voltage
A1, A2, B, C, indices S, R
0 °C to +90 °C
(+32 °F to +194 °F)
7.6 V - 30 V DC
Quiescent current
approx. 0.15 mA
Response temperatures
Alarm current consumption
Alarm indication
Normal operation indication
Current indication
Fault indication
Fault indication
Operating temperature
IP rating (EN 60529)
Enclosure material
Relative humidity
(IEC721-3-3)
Speci¿cation according to
P31.312.110 - 1en / 02.14
Weight
Dimensions
Not included in delivery
Base UniVario MX5000
Bracket MX5000
Terminating resistor 1.8 K / 0.5 W
Technical specifications
approx. 15 mA
904701
904757
675235
Connection / mounting
Connection cable standard detector
2-lead
Additional fault line connection
2-lead
External indication
2-lead
Recommended cable
JY (St) Y 2x2x0.8 mm (0.03 inch)
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Approvals / marking
1 red LED
1 green LED, Àashing
801297
910134
905883
G 207090
0786-CPD-20280
approx. 15 mA
1 yellow LED (2nd line)
-20 °C to +80 °C
(-4 °F to +176 °F)
IP 67
Diecast aluminium
0 to 95%
no condensation
EN 54 Part 5
520 g (1.2 lbs)
130 x 84 mm (dia. x H)
5.1 x 3.3 inch (dia. x H)
WMX5000 CN
Order no.: 909375
Version China
Approvals / marking
Technical data see Order no 905441
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 6 - 9
Product Sheet | Detecon
Industrial detectors
UniVario Heat detectors, standard
UniVario WMX5000 single hole
Order no.: 905847
The single hole mounted WMX5000 heat detectors are
speci¿cally designed for use in dryer and ventilation ducts for
the detection of ¿res with rapid rise in temperature, e.g.:
– Flammable liquids and gases
– Highly Àammable plastics.
In addition to ¿xed temperature detection, rapid rises in
temperature can also be registered by the rate-of-rise
method, for early ¿re detection.
Designed for operation as a conventional detector.
Expansion to a detector with Loop AP protocol via KMX5000 AP
communication module.
Product features
Optional accessories
•
Robust stainless steel heat sensor, resistant to impact
and vibration.
•
Freely con¿gurable response temperatures and classes in
accordance with EN54-5, along with rate-of-rise and static
responses. Con¿guration via DIP switches on the detector.
Parallel indicator
Weather protection MX5000 complete
KMX5000 AP communication module
Silicone-free design
•
Service interface, history memory.
•
Connection of remote indicator possible.
Detection method
NTC sensor
Response classes
Operating voltage
A1, A2, B, C, D indices S, R
0 °C to +105 °C
(+32 °F to +221 °F)
7.6 V - 30 V DC
Quiescent current
approx. 0.15 mA
Response temperatures
Alarm current consumption
Alarm indication
Normal operation indication
Current indication
Fault indication
Fault indication
Operating temperature
IP rating (EN 60529)
Enclosure material
Relative humidity
(IEC721-3-3)
Speci¿cation according to
P31.312.110 - 3en / 02.14
Weight
Dimensions
Not included in delivery
Base UniVario MX5000
Single hole mounting ¿xture
Single hole mounting tool
Terminating resistor 1.8 K / 0.5 W
Technical specifications
approx. 15 mA
1 red LED
1 green LED, Àashing
908499
910134
905883
904701
800034
800388
675235
Connection / mounting
Connection cable standard detector
2-lead
Additional fault line connection
2-lead
External indication
2-lead
Recommended cable
JY (St) Y 2x2x0.8 mm (0.03 inch)
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Approvals / marking
G 207090
0786-CPD-20280
approx. 15 mA
1 yellow LED (2nd line)
-20 °C to +80 °C
(-4 °F to +176 °F)
IP 67
Diecast aluminium
0 to 95%
no condensation
EN 54 Part 5
580 g (1.3 lbs)
130 x 133 mm (dia. x H)
5.1 x 5.2 inch (dia. x H)
WMX5000 single hole CN
Order no.: 909376
Version China
Approvals / marking
Technical data see Order no 905847
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 6 - 10
Product Sheet | Detecon
Industrial detectors
UniVario High temperature heat detector FS
WMX5000 FS 400°C (752 °F)
Order no.: 905505
The WMX5000 FS high temperature heat detectors
have been specially designed for operation in industrial
environments with aggressive media and very high
application temperatures in the monitoring area. For example
in exhaust ducts, engine test stands or machine tools.
In addition to ¿xed temperature detection, rapid rises in
temperature can also be registered by the rate-of-rise
method, for early ¿re detection.
Designed for operation as a conventional detector.
Expansion to a detector with Loop AP protocol via KMX5000 AP
communication module.
Product features
Optional accessories
•
•
Parallel indicator
KMX5000 AP communication module
Silicone-free design
•
•
Robust stainless steel heat rod sensor
Freely con¿gurable response temperatures and classes
in accordance with EN54-5, along with rate-of-rise and
static responses. Con¿guration via DIP switches on the
detector.
Service interface, history memory.
Connection of remote indicator possible.
Technical specifications
Detection method
Operating voltage
PT1000 sensor
A1, A2, B, C, D, E, F, G,
indices S, R
0 °C to +400 °C
(+32 °F to +752 °F)
7.6 V - 30 V DC
Quiescent current
approx. 0.25 mA
Response classes
Response temperatures
Alarm current consumption
approx. 15 mA
Alarm indication
1 red LED
Normal operation indication
Current consumption
Fault indication
Fault indication
1 green LED, Àashing
approx. 15 mA
1 yellow LED (2nd line)
-20 °C to +80 °C
(-4 °F to +176 °F)
IP 67
Operating temperature
IP rating (EN 60529)
Enclosure material
Relative humidity
(IEC721-3-3)
Speci¿cation according to
Weight
P31.312.130en / 02.14
Dimensions
908499
905883
Not included in delivery
Base UniVario MX5000
Single hole mounting ¿xture
Single hole mounting tool
Terminating resistor 1.8 K / 0.5 W
904701
800034
800388
675235
Connection / mounting
Connection cable standard detector
2-lead
Additional fault line connection
2-lead
External indication
2-lead
Recommended cable
JY (St) Y 2x2x0.8 mm (0.03 inch)
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Note
The desired length of the sensor rod must be speci¿ed in
millimetres at the time of placing the order. Alternatively,
¿xed standard rod lengths are available to choose from.
Approvals / marking
G 207091
0786-CPD-20281
Diecast aluminium
0 to 95%
no condensation
EN 54 Part 5
520 to 1600 g (1.2 to 3.5 lbs)
130 x 150 to 1500 mm (dia. x H)
5.1 x 5.9 x 59.1 inch (dia. x H)
WMX5000 FS 400 °C (752 °F) CN
Order no.: 909378
Version China
Approvals / marking
Otherwise like Order no 905505
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 6 - 11
Product Sheet | Detecon
Industrial detectors
UniVario High temperature heat detector FS
WMX5000 FS 400 °C 200 mm
(752 °F 7.9 inch)
Order no.: 906401
Version with ¿xed rod length of 200 mm (7.9 inch)
Otherwise like Order no.: 905505
Technical specifications
Response temperatures
Weight
Dimensions
0 °C to +400 °C
(+32 °F to +752 °F)
680 g (1.5 lbs)
130 x 260 mm (dia. x H)
5.1 x 10.2 inch (dia. x H)
WMX5000 FS 400 °C 400 mm
(752 °F 15.8 inch)
Order no.: 906402
Version with ¿xed rod length of 400 mm (15.8 inch)
Otherwise like Order no.: 905505
Technical specifications
Response temperatures
Weight
Dimensions
0 °C to +400 °C
(+32 °F to +752 °F)
840 g (1.9 lbs)
130 x 460 mm (dia. x H)
5.1 x 18.1 inch (dia. x H)
WMX5000 FS 400 °C 600 mm
(752 °F 23.6 inch)
Order no.: 906403
Version with ¿xed rod length of 600 mm (33.6 inch)
Otherwise like Order no.: 905505
Technical specifications
Response temperatures
Weight
P31.312.130en / 02.14
Dimensions
0 °C to +400 °C
(+32 °F to +752 °F)
1000 g (2.2 lbs)
130 x 660 mm (dia. x H)
5.1 x 26 inch (dia. x H)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 6 - 12
Product Sheet | Detecon
Industrial detectors
UniVario High temperature heat detector FS
WMX5000 FS 850°C (1562 °F)
Order no.: 906454
The WMX5000 FS high temperature heat detectors
have been specially designed for operation in industrial
environments with aggressive media and very high
application temperatures in the monitoring area. For example
in exhaust ducts, engine test stands or machine tools.
In addition to ¿xed temperature detection, rapid rises in
temperature can also be registered by the rate-of-rise
method, for early ¿re detection.
Designed for operation as a conventional detector.
Expansion to a detector with Loop AP protocol via KMX5000 AP
communication module.
Product features
Optional accessories
•
•
Parallel indicator
KMX5000 AP communication module
•
•
Robust stainless steel heat rod sensor
Freely con¿gurable response temperatures and classes
in accordance with EN54-5, along with rate-of-rise and
static responses. Con¿guration via DIP switches on the
detector.
Service interface, history memory.
Connection of remote indicator possible.
Technical specifications
Detection method
Operating voltage
PT1000 sensor
A1, A2, B, C, D, E, F, G,
indices S, R
0 °C to +840 °C
(+32 °F to +1544 °F)
7.6 V - 30 V DC
Quiescent current
approx. 0.35 mA
Response classes
Response temperatures
Alarm current consumption
Alarm indication
Normal operation indication
Current consumption
Fault indication
Fault indication
Operating temperature
IP rating (EN 60529)
Enclosure material
Relative humidity
(IEC721-3-3)
Speci¿cation according to
Weight
P31.312.130en / 02.14
Dimensions
approx. 15 mA
1 red LED
1 green LED, Àashing
908499
905883
Silicone-free design
Not included in delivery
Base UniVario MX5000
Single hole mounting ¿xture
Single hole mounting tool
Terminating resistor 1.8 K / 0.5 W
904701
800034
800388
675235
Connection / mounting
Connection cable standard detector
2-lead
Additional fault line connection
2-lead
External indication
2-lead
Recommended cable
JY (St) Y 2x2x0.8 mm (0.03 inch)
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Note
The desired length of the sensor rod must be speci¿ed in
millimetres at the time of placing the order.
approx. 15 mA
1 yellow LED (2nd line)
-20 °C to +80 °C
(-4 °F to +176 °F)
IP 67
Diecast aluminium
0 to 95%
no condensation
EN 54 Part 5
520 to 1600 g (1.2 to 3.5 lbs)
130 x 150 to 1500 mm (dia. x H)
5.1 x 5.9 x 59.1 inch (dia. x H)
Approvals / marking
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 6 - 13
Product Sheet | Detecon
Industrial detectors
UniVario High temperature heat detector FS Flex
WMX5000 FS Flex 400°C (752 °F)
Order no.: 906176
The WMX5000 FS high temperature heat detectors
have been specially designed for operation in industrial
environments with aggressive media and very high
application temperatures in the monitoring area. For example
in exhaust ducts, engine test stands or machine tools.
In addition to ¿xed temperature detection, rapid rises in
temperature can also be registered by the rate-of-rise
method, for early ¿re detection.
Designed for operation as a conventional detector.
Expansion to a detector with Loop AP protocol via KMX5000 AP
communication module.
Product features
Optional accessories
•
•
Parallel indicator
KMX5000 AP communication module
•
•
Robust Àexible stainless steel heat sensor
Freely con¿gurable response temperatures and classes
in accordance with EN54-5, along with rate-of-rise and
static responses. Con¿guration via DIP switches on the
detector.
Service interface, history memory.
Connection of remote indicator possible.
Technical specifications
Detection method
Operating voltage
PT1000 sensor
A1, A2, B, C, D, E, F, G,
indices S, R
0 °C to +400 °C
(+32 °F to +752 °F)
7.6 V - 30 V DC
Quiescent current
approx. 0.25 mA
Response classes
Response temperatures
Alarm current consumption
Alarm indication
Normal operation indication
Current consumption
Fault indication
Fault indication
Operating temperature
IP rating (EN 60529)
Enclosure material
Relative humidity
(IEC721-3-3)
Speci¿cation according to
Weight
1 red LED
1 green LED, Àashing
approx. 15 mA
1 yellow LED (2nd line)
-20 °C to +80 °C
(-4 °F to +176 °F)
IP 67
Diecast aluminium
0 to 95%
no condensation
EN 54 Part 5
Silicone-free design
Not included in delivery
Base UniVario MX5000
Holder WMX FS, from
250 °C (482 °F) to 600 °C (1112 °F)
Terminating resistor 1.8 K / 0.5 W
904701
894679
675235
Connection / mounting
Connection cable standard detector
2-lead
Additional fault line connection
2-lead
External indication
2-lead
Recommended cable
JY (St) Y 2x2x0.8 mm (0.03 inch)
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Note
The desired length of the Àexible sensor rod must be
speci¿ed in metres at the time of placing the order.
The sensor rod holder is designed for application
temperatures of up to 250 °C (482 °F). In case of higher
application temperatures, the holder WMX FS from 250 °C
(482 °F) to 600°C (1112 °F) Order no. 804679 is to be used.
Approvals / marking
G 207091
0786-CPD-20281
520 to 1600 g (1.2 to 3.5 lbs)
130 x 2000 to 9000 mm (dia. x H)
5.1 x 78.7 x 354.3 inch (dia. x H)
P31.312.150en / 01.14
Dimensions
approx. 15 mA
908499
905883
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 6 - 14
Product Sheet | Detecon
Industrial detectors
UniVario High temperature heat detector FS Flex
WMX5000 FS Flex 400 °C 2 m
(752 °F 79 inch)
Order no.: 906404
Version with Àexible hose of 2 m length (79 inch)
Otherwise like Order no.: 906176
Technical specifications
Response temperatures
Weight
Dimensions
0 °C to +400 °C
(+32 °F to +752 °F)
680 g (1.5 lbs)
130 x up to 2000 mm (dia. x H)
5.1 x up to 78.73 inch (dia. x H)
WMX5000 FS Flex 400 °C 6 m
(752 °F 236 inch)
Order no.: 906405
Version with Àexible hose of 6 m length (236 inch)
Otherwise like Order no.: 906176
Technical specifications
Response temperatures
Weight
Dimensions
0 °C to +400 °C
(+32 °F to +752 °F)
840 g (1.9 lbs)
130 x up to 6000 mm (dia. x H)
5.1 x up to 236.2 inch (dia. x H)
WMX5000 FS Flex 400 °C 9 m
(752 °F 354 inch)
Order no.: 906406
Version with Àexible hose of 9 m length (354 inch)
Otherwise like Order no.: 906176
Technical specifications
Response temperatures
Weight
P31.312.150en / 01.14
Dimensions
0 °C to +400 °C
(+32 °F to +752 °F)
1000 g (2.2 lbs)
130 x up to 9000 mm (dia. x H)
5.1 x up to 354.3 inch (dia. x H)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 6 - 15
Product Sheet | Detecon
Industrial detectors
UniVario High temperature heat detector FS Flex
WMX5000 FS Flex 850°C (1562 °F)
Order no.: 906455
The WMX5000 FS high temperature heat detectors
have been specially designed for operation in industrial
environments with aggressive media and very high
application temperatures in the monitoring area. For example
in exhaust ducts, engine test stands or machine tools.
In addition to ¿xed temperature detection, rapid rises in
temperature can also be registered by the rate-of-rise
method, for early ¿re detection.
Designed for operation as a conventional detector.
Expansion to a detector with Loop AP protocol via KMX5000 AP
communication module.
Product features
Optional accessories
•
•
Parallel indicator
KMX5000 AP communication module
Silicone-free design
•
•
Robust Àexible stainless steel heat sensor.
Freely con¿gurable response temperatures and classes
in accordance with EN54-5, along with rate-of-rise and
static responses. Con¿guration via DIP switches on the
detector.
Service interface, history memory.
Connection of remote indicator possible.
Operating voltage
PT1000 sensor
A1, A2, B, C, D, E, F, G,
indices S, R
0 °C to +840 °C
(+32 °F to +1544 °F)
7.6 V - 30 V DC
Quiescent current
approx. 0.35 mA
Response classes
Response temperatures
Alarm current consumption
Alarm indication
Normal operation indication
Current consumption
Fault indication
Fault indication
Operating temperature
IP rating (EN 60529)
Enclosure material
Relative humidity
(IEC721-3-3)
Speci¿cation according to
Weight
P31.312.150en / 01.14
Dimensions
Not included in delivery
Base UniVario MX5000
Terminating resistor 1.8 K / 0.5 W
904701
675235
Connection / mounting
Technical specifications
Detection method
908499
905883
approx. 15 mA
1 red LED
Connection cable standard detector
2-lead
Additional fault line connection
2-lead
External indication
2-lead
Recommended cable
JY (St) Y 2x2x0.8 mm (0.03 inch)
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Note
The desired length of the Àexible sensor rod must be
speci¿ed in metres at the time of placing the order.
Approvals / marking
1 green LED, Àashing
approx. 15 mA
1 yellow LED (2nd line)
-20 °C to +80 °C
(-4 °F to +176 °F)
IP 67
Diecast aluminium
0 to 95%
no condensation
EN 54 Part 5
520 to 1600 g (1.2 to 3.5 lbs)
130 x 2000 to 9000 mm (dia. x H)
5.1 x 78.7 x 354.3 inch (dia. x H)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 6 - 16
Product Sheet | Detecon
Industrial detectors
UniVario IR flame detector, Ex
UniVario FMX5000 IR 3GD
Order no.: 909481
Triple IR Àame detector for the detection of typcal ¿res.
Including 3 channel optic test monitoring all functionalties of
detector.
ATEX-approved for category 3, Gas and Dust, suitable for
use in Ex zones 2 and 22.
The detector must not connected with a safety barrier and a
blue ¿re alarm cable.
Designed for use in rough industrial environments.
Equipped for operation as a conventional detector.
Expansion to a detector with Loop AP protocol via KMX5000 AP
communication module.
Product features
Optional accessories
•
Highly reliable against false alarms, e.g. from hot surfaces or sunlight.
•
A microcontroller monitors the functionality and analyses
the recorded data. Faults can be indicated on the
detector or on a separate line.
Parallel indicator LMX5000
KMX5000 AP communication module
Weather protection MX5000 complete
Silicone-free design
•
Service interface, history memory.
•
Connection of remote indicator possible.
•
3-channel optic test.
•
For use in Ex zones 2 and 22, ATEX category 3 Gas/
Dust
Sensitivity class
Viewing angle
1
90°
Quiescent current
2.3 mA
Fault indication current
Fault indication
Operating temperature
IP rating (EN 60529)
Enclosure material
Relative humidity
(IEC721-3-3)
Speci¿cation according to
P31.312.340 - 1en / 01.14
3 IR Sensors
7.6 V - 30 V DC
Alarm indication
Weight
Dimensions
904701
904757
675235
Connection / mounting
Operating voltage
Alarm current
Not included in delivery
Base UniVario MX5000
Bracket MX5000
Terminating resistor 1.8 K / 0.5 W
Technical specifications
Detection method
908499
905883
910134
approx. 15 mA
1 LED red
Connection cable standard detector
2-lead
Additional fault line connection
2-lead
External indication
2-lead
Recommended cable
JY (St) Y 2x2x0.8 mm (0.03 inch)
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Note
The detector will be delivered with two Ex cable glands.
These cable glands have to be used at the base.
Approvals / marking
Ex conformity in acc. with 94/9/EG:
x II 3G Ex nAc IIC T4
x II 3D Ex tc IIIC T110°C IP65
approx. 15 mA
1 LED yellow
-20 °C to +80 °C
(-4 °F to +176 °F)
IP 67
Diecast aluminium
0 to 95%
no condensation
EN 54 Part 10
Type examination certi¿cate:
BVS 11 ATEX E135
Ex conformity Russia in acc. with TP TC 012/2011:
1Ex ia IIC T6/T4 Gb
0Ex ia IIC T6/T4 Ga
Ex ia IIIC T95°C Da
G 209141
0786-CPD-20784
820 g (1.8 lbs)
100 x 50 mm (dia. x H)
3.9 x 2 inch (dia. x H)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 6 - 17
Product Sheet | Detecon
Industrial detectors
UniVario IR flame detector, Ex
FMX5000 IR Ex
Order no.: 911674
Triple IR Àame detector for the detection of typical ¿res.
Including 3 channel optic test monitoring all functionalties of
detector.
ATEX and IECEx approved for category 2 Gas and 1, 2 Dust,
suitable for use in Ex zones 1, 20 and 21.
The detectors must be connected via a safety barrier.
Designed for use in tough industrial environments. Equipped
for operation as a conventional detector.
Extension to a detector with Loop AP protocol via the
KMX5000 AP Ex. communication module.
Product features
Optional accessories
•
Highly reliable against false alarms, e.g. from hot surfaces or sunlight.
•
A microcontroller monitors the functionality and analyses
the recorded data. Faults can be indicated on the
detector or on a separate line.
Safety barrier IS conventional 9 V
Safety barrier IS addressable 24 V
KMX5000 AP Ex communication module
Weather protection MX5000 complete
Silicone-free design
•
Service interface, history memory.
Not included in delivery
•
Connection of remote indicator possible.
•
3-channel optic test.
•
For use in Ex zones 1, 20 and 21, ATEX category 2
Gas/1, 2 Dust.
Base UniVario MX5000 Ex
Bracket MX5000
Terminating resistor 1.8 K / 0.5 W
Sensitivity class
Viewing angle
Operating voltage
Quiescent current
Alarm current
Alarm indication
Fault indication current
Fault indication
P31.312.340 - 1en / 01.14
3 IR Sensors
1
7.6 V - 30 V DC
4.5 mA
1 LED red
approx. 15 mA
Enclosure material
Relative humidity
(IEC721-3-3)
Speci¿cation according to
Diecast aluminium
0 to 95%
no condensation
EN 54 Part 10
Dimensions
Approvals / marking
Ex conformity in acc. with 94/9/EG:
x II 2G Ex ia IIC T6/T4 Gb
x II 1D Ex ia IIIC T95°C Da
approx. 15 mA
IP rating (EN 60529)
Weight
Connection cable standard detector
2-lead
Additional fault line connection
2-lead
External indication
2-lead
Recommended cable
JY (St) Y 2x2x0.8 mm (0.03 inch)
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
90°
1 LED yellow
-25 °C to +80 °C
(-13 °F to +176 °F)
IP 67
Operating temperature
912082
904757
675235
Connection / mounting
Technical specifications
Detection method
904991
901324
912086
910134
Type examination certi¿cate:
BVS 12 ATEX E088
IECEx conformity:
IECEx BVS 12.0056
Ex conformity Russia in acc. with TP TC 012/2011:
1Ex ia IIC T6/T4 Gb
0Ex ia IIC T6/T4 Ga
Ex ia IIIC T95°C Da
G 209141
0786-CPD-20784
860 g (1.9 lbs)
100 x 50 mm (dia. x H)
3.9 x 2 inch (dia. x H)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 6 - 18
Product Sheet | Detecon
Industrial detectors
UniVario UV flame detector Ex
FMX5000 UV 3GD
Order no.: 907267
UV Àame detector for detection of typical ¿res. Designed
for use in harsh industrial environments. Fitted for use as a
conventional detector.
The WMX5000 UV 3GD UV Àame detectors are Atex approved for Category 3 gas and dust and are intended for use in
Ex Zones 2 and 22.
Expansion to a detector with Loop AP protocol via the
KMX5000 AP communications module.
The Àame detector features a built-in optical channel function
test.
Product features
Optional accessories
•
High degree of immunity against false alarms, such as
storm lightning or strong sunlight.
•
Function monitoring and evaluation of measured values
by microcontroller, faults can be displayed on the detector or a separate line.
Parallel indicator LMX5000
KMX5000 AP communication module
Weather protection MX5000 complete
Silicone-free design
•
Service interface, history memory.
•
Connection of external display possible.
•
Use in Ex Zones 2 and 22 Atex Categorie 3 gas/dust.
Not included in delivery
Base UniVario MX5000
Bracket MX5000
Terminating resistor 1,8 K / 0,5 W
Technical specifications
Detection method
Sensitivity class
Viewing angle
1
90°
Quiscent current
approx. 0.25 mA
approx. 15 mA
Alarm indication
1 LED red
Fault indication current
ca. 15 mA
Operating temperature
IP rating (EN 60529)
Enclosure material
Relative humidity
(IEC721-3-3)
Speci¿cation according to
Weight
P31.312.320 - 1en / 01.14
UV-Sensor
7.6 V - 30 V DC
Fault indication
Dimensions
904701
904757
675235
Connection / mounting
Operating voltage
Alarm current
908499
905883
910134
1 LED yellow
-20 °C to +80 °C
(-4 °F to +176 °F)
IP 67
Diecast aluminium
0 to 95%
no condensation
EN 54 Part 10
820 g (1.8 lbs)
100 x 50 mm (DxH)
3.9 x 2 inch (dia. x H)
Connection cable standard detector
2-lead
Additional fault line connection
2-lead
External indication
2-lead
Recommended cable
JY (St) Y 2x2x0.8 mm (0.03 inch)
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Note
The detector will be delivered with two Ex cable glands.
These cable glands have to be used at the base.
Approvals / marking
Ex conformity in acc. with 94/9/EG:
x II 3G Ex nAc IIC T4
x II 3D Ex tc IIIC T110°C IP65
EC type approval certi¿cate:
BVS 11 ATEX E137
Ex conformity Russia in acc. with TP TC 012/2011:
2Ex nAc IIC T4
Ex tc IIIC T110°C IP65
applied fo
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
applied fo
Chapter 6 - 19
Product Sheet | Detecon
Industrial detectors
UniVario Heat detectors, Ex standard
WMX5000 3GD
Order no.: 907268
The WMX5000 3GD heat detectors are ATEX-approved
for category 3, gas and dust, and are suitable for use in
Ex zones 2 and 22. They are designed to detect open ¿res
with rapid rise of temperature, e.g.:
– Flammable liquids and gases
– Highly Àammable plastics.
They are designed speci¿cally for operation in dirty industrial
environments, both indoors and outdoors. In addition to
stated temperature detection, rapid rises in temperature can
also be registered by the rate-of-rise method, for early ¿re
detection.
Product features
Equipped for operation as a conventional detector. Extension
to a detector with Loop AP protocol via the KMX5000 AP
communication module.
•
•
Optional accessories
•
•
•
Robust stainless steel heat sensor.
Freely con¿gurable response temperatures and classes
in accordance with EN54-5, along with rate-of-rise
and static responses. Setting via DIP switches on the
detector or SMX5000 service device.
Service interface, history memory.
Connection of remote indicator possible.
For use in Ex zones 2 and 22, ATEX category 3 Gas/
Dust.
Technical specifications
NTC sensor
Response classes
Operating voltage
A1, A2, B, C, indices S, R
0 °C to +90 °C
(+32 °F to +194 °F)
7.6 V - 30 V DC
Quiescent current
approx. 0.15 mA
Alarm current consumption
Alarm indication
Normal operation indication
Current indication
Fault indication
Fault indication
Operating temperature
IP rating (EN 60529)
P31.312.120 - 1en / 01.14
Enclosure material
Relative humidity
(IEC721-3-3)
Speci¿cation according to
Weight
Dimensions
908499
905883
Not included in delivery
Base UniVario MX5000
Bracket MX5000
Terminating resistor 1.8 K / 0.5 W
904701
904757
675235
Connection / mounting
Detection method
Response temperatures
Parallel indicator
KMX5000 AP communication module
Silicone-free design
approx. 15 mA
1 red LED
1 green LED, Àashing
approx. 15 mA
1 yellow LED (2nd line)
-20 °C to +80 °C
(-4 °F to +176 °F)
IP 67
Connection cable standard detector
2-lead
Additional fault line connection
2-lead
External indication
2-lead
Recommended cable
JY (St) Y 2x2x0.8 mm (0.03 inch)
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Approvals / marking
Ex conformity in acc. with 94/9/EC:
x II 3G Ex nA II T4
x II 3D Ex tD A22 IP65 T110°C
Type examination certi¿cate:
BVS 07 ATEX E 156
Ex conformity Russia in acc. with TP TC 012/2011:
2Ex nAc IIC T4
Ex tc IIIC T110°C IP65
G 207090
0786-CPD-20280
Diecast aluminium
0 to 95%
no condensation
EN 54 Part 5
520 g (1.2 lbs)
130 x 84 mm (dia. x H)
5.1 x 3.3 inch (dia. x H)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 6 - 20
Product Sheet | Detecon
Industrial detectors
UniVario Heat detectors, Ex standard
WMX5000 Ex
Order no.: 912117
The WMX5000 3 Ex heat detectors are ATEX and IECEx
approved for category 2 gas and 1,2 dust, and are suitable
for use in Ex zones 1, 20 and 21. They are designed to
detect open ¿res with rapid rise of temperature, e.g.:
– Flammable liquids and gases
– Highly Àammable plastics.
They are designed speci¿cally for operation in dirty industrial
environments, both indoors and outdoors. In addition to
stated temperature detection, rapid rises in temperature can
also be registered by the rate-of-rise method, for early ¿re
detection.
Product features
Equipped for operation as a conventional detector. Extension
to a detector with Loop AP protocol via the KMX5000 AP Ex
communication module.
•
•
Optional accessories
•
•
•
Robust stainless steel heat sensor.
Freely con¿gurable response temperatures and classes
in accordance with EN54-5, along with rate-of-rise
and static responses. Setting via DIP switches on the
detector or SMX5000 service device.
Service interface, history memory.
Connection of remote indicator possible.
For use in Ex zones 1, 20 and 21, ATEX category 2
Gas/1, 2Dust.
Technical specifications
Detection method
NTC sensor
Response classes
Operating voltage
A1, A2, B, C, indices S, R
0 °C to +90 °C
(+32 °F to +194 °F)
7.6 V - 30 V DC
Quiescent current
approx. 2.8 mA
Alarm current consumption
approx. 15 mA
Response temperatures
Alarm indication
Normal operation indication
Current indication
Fault indication
Fault indication
Operating temperature
IP rating (EN 60529)
P31.312.120 - 1en / 01.14
Enclosure material
Relative humidity
(IEC721-3-3)
Speci¿cation according to
Weight
Dimensions
1 red LED
1 green LED, Àashing
approx. 15 mA
1 yellow LED (2nd line)
-25 °C to +80 °C
(-13 °F to +176 °F)
IP 67
Diecast aluminium
0 to 95%
no condensation
EN 54 Part 5
Safety barrier IS conventional 9 V
Safety barrier IS addressable 24 V
KMX5000 AP Ex communication module
Weather protection MX5000 complete
Silicone-free design
904991
901324
912086
910134
Not included in delivery
Base UniVario MX5000 Ex
Bracket MX5000
Terminating resistor 1.8 K / 0.5 W
912082
904757
675235
Connection / mounting
Connection cable standard detector
2-lead
Additional fault line connection
2-lead
External indication
2-lead
Recommended cable
JY (St) Y 2x2x0.8 mm (0.03 inch)
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Approvals / marking
Ex conformity in acc. with 94/9/EG:
x II 2G Ex ia IIC T6/T4 Gb
x II 1D Ex ia IIIC T95°C Da
Type examination certi¿cate:
BVS 12 ATEX E121
IECEx conformity:
IECEx BVS 12.0074
Ex conformity Russia in acc. with TP TC 012/2011:
1Ex ia IIC T6/T4 Gb
0Ex ia IIC T6/T4 Ga
Ex ia IIIC T95°C Da
G 207090
0786-CPD-20280
520 g (1.2 lbs)
130 x 84 mm (dia. x H)
5.1 x 3.3 inch (dia. x H)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 6 - 21
Product Sheet | Detecon
Industrial detectors
UniVario Heat detectors, Ex standard
WMX5000 3GD single hole
Order no.: 907269
The single hole mounted WMX5000 3GD heat detectors
are ATEX-approved for category 3, gas and dust, and are
suitable for use in Ex zones 2 and 22. They are speci¿cally
suited for use in dryer and ventilation ducts for the detection
of ¿res with rapid rise in temperature, e.g.:
– Flammable liquids and gases
– Highly Àammable plastics.
In addition to stated temperature detection, rapid rises
in temperature can also be registered by the rate-of-rise
method, for early ¿re detection.
Equipped for operation as a conventional detector. Extension
to a detector with Loop AP protocol via the KMX5000 AP
communication module.
Product features
•
•
•
•
•
Robust stainless steel heat sensor, resistant against
impact and vibration.
Freely con¿gurable response temperatures and classes
in accordance with EN54-5, along with rate-of-rise and
static responses. Con¿guration via DIP switches on the
detector or SMX5000 service device.
Service interface, history memory.
Connection of remote indicator possible.
For use in Ex zones 2 and 22, ATEX category 3, Gas/
Dust.
Technical specifications
Detection method
NTC sensor
Response classes
Operating voltage
A1, A2, B, C, D, indices S, R
0 °C to +105 °C
(+32 °F to +221 °F)
7.6 V - 30 V DC
Quiescent current
approx. 0.15 mA
Response temperatures
Alarm current consumption
Alarm indication
Normal operation indication
Current indication
Fault indication
Fault indication
Operating temperature
IP rating (EN 60529)
P31.312.120 - 2en / 01.14
Enclosure material
Relative humidity
(IEC721-3-3)
Speci¿cation according to
Weight
Dimensions
approx. 15 mA
1 red LED
1 green LED, Àashing
approx. 15 mA
1 yellow LED (2nd line)
-20 °C to +80 °C
(-4 °F to +176 °F)
IP 67
Optional accessories
Parallel indicator
Weather protection MX5000 complete
KMX5000 AP communication module
Silicone-free design
908499
910134
905883
Not included in delivery
Base UniVario MX5000
Single hole mounting ¿xture
Single hole mounting tool
Terminating resistor 1.8 K / 0.5 W
904701
800034
800388
675235
Connection / mounting
Connection cable standard detector
2-lead
Additional fault line connection
2-lead
External indication
2-lead
Recommended cable
JY (St) Y 2x2x0.8 mm (0.03 inch)
Line cross-section
max. 2.5 mm2 (0.004 square inch)
Approvals / marking
Ex conformity in acc. with 94/9/EC:
x II 3G Ex nA II T4
x II 3D Ex tD A22 IP65 T110°C
Type examination certi¿cate:
BVS 07 ATEX E 156
Ex conformity Russia in acc. with TP TC 012/2011:
2Ex nAc IIC T4
Ex tc IIIC T110°C IP65
G 297090
0786-CPD-20280
Diecast aluminium
0 to 95%
no condensation
EN 54 Part 5
580 g (1.3 lbs)
130 x 133 mm (dia. x H)
5.1 x 5.2 inch (dia. x H)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 6 - 22
Product Sheet | Detecon
Industrial detectors
UniVario Heat detectors, Ex standard
WMX5000 Ex single hole
Order no.: 912118
The single hole mounted WMX5000 Ex heat detectors
are ATEX-approved for category 2, gas and 1, 2 dust, and
are suitable for use in Ex zones 1, 20 and 21. They are
speci¿cally suited for use in dryer and ventilation ducts for the
detection of ¿res with rapid rise in temperature, e.g.:
– Flammable liquids and gases
– Highly Àammable plastics.
In addition to stated temperature detection, rapid rises
in temperature can also be registered by the rate-of-rise
method, for early ¿re detection.
Equipped for operation as a conventional detector. Extension
to a detector with Loop AP protocol via the KMX5000 AP Ex
communication module.
Product features
•
•
•
•
•
Robust stainless steel heat sensor, resistant against
impact and vibration.
Freely con¿gurable response temperatures and classes
in accordance with EN54-5, along with rate-of-rise and
static responses. Con¿guration via DIP switches on the
detector or SMX5000 service device.
Service interface, history memory.
Connection of remote indicator possible.
For use in Ex zones 1, 20 and 21, ATEX category 2, Gas/
1, 2 Dust.
Technical specifications
NTC sensor
Response classes
Operating voltage
A1, A2, B, C, D, indices S, R
0 °C to +105 °C
(+32 °F to +221 °F)
7.6 V - 28 V DC
Quiescent current
approx. 3.0 mA
Alarm current consumption
approx. 15 mA
Alarm indication
Normal operation indication
Current indication
Fault indication
Fault indication
Operating temperature
P31.312.120 - 2en / 01.14
IP rating (EN 60529)
Enclosure material
Relative humidity
(IEC721-3-3)
Speci¿cation according to
Weight
Dimensions
Safety barrier IS conventional 9 V
Safety barrier IS addressable 24 V
KMX5000 AP Ex communication module
Silicone-free design
904991
901324
912086
Not included in delivery
Base UniVario MX5000 Ex
Single hole mounting ¿xture
Single hole mounting tool
Terminating resistor 1.8 K / 0.5 W
912082
800034
800388
675235
Connection / mounting
Detection method
Response temperatures
Optional accessories
Connection cable standard detector
2-lead
Additional fault line connection
2-lead
Recommended cable
JY (St) Y 2x2x0.8 mm (0.03 inch)
Line cross-section
max. 2.5 mm2 (0.004 square inch)
Approvals / marking
Ex conformity in acc. with 94/9/EG:
x II 2G Ex ia IIC T6/T4 Gb
x II 1D Ex ia IIIC T95°C Da
1 red LED
1 green LED, Àashing
approx. 15 mA
1 yellow LED (2nd line)
-25 °C to +80 °C
(-13 °F to +176 °F)
IP 67
Diecast aluminium
0 to 95%
no condensation
EN 54 Part 5
Type examination certi¿cate:
BVS 12 ATEX E121
IECEx conformity:
IECEx BVS 12.0074
Ex conformity Russia in acc. with TP TC 012/2011:
1Ex ia IIC T6/T4 Gb
0Ex ia IIC T6/T4 Ga
Ex ia IIIC T95°C Da
G 207090
0786-CPD-20280
580 g (1.3 lbs)
130 x 133 mm (dia. x H)
5.1 x 5.2 inch (dia. x H)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 6 - 23
Product Sheet | Detecon
Industrial detectors
UniVario High temperature heat detector FS, Ex
WMX5000 FS 3GD 400°C (752 °F)
Order no.: 907270
The WMX5000 FS 3GD high temperature heat detectors
are ATEX-approved for category 3, gas and dust, and are
suitable for use in Ex zones 2 and 22. They have been
specially designed for operation in industrial environments
with aggressive media and very high application
temperatures in the monitoring area. For example in exhaust
ducts, engine test stands or machine tools.
In addition to stated temperature detection, rapid rises
in temperature can also be registered by the rate-of-rise
method, for early ¿re detection.
Equipped for operation as a conventional detector. Extension
to a detector with Loop AP protocol via the KMX5000 AP
communication module.
Product features
•
•
•
•
•
Robust stainless steel heat rod sensor.
Freely con¿gurable response temperatures and classes
in accordance with EN54-5, along with rate-of-rise and
static responses. Con¿guration via DIP switches on the
detector or SMX5000 service device.
Service interface, history memory.
Connection of remote indicator possible.
For use in Ex zones 2 and 22, Atex category 3, Gas/Dust.
Technical specifications
Detection method
Operating voltage
Quiescent current
approx. 0.25 mA
Response temperatures
Alarm current consumption
Alarm indication
Normal operation indication
Current consumption
Fault indication
Fault indication
Operating temperature
IP rating (EN 60529)
Enclosure material
Relative humidity
(IEC721-3-3)
Speci¿cation according to
P31.312.140en / 01.14
Weight
Dimensions
Parallel indicator
KMX5000 AP communication module
Silicone-free design
908499
905883
Not included in delivery
Base UniVario MX5000
Single hole mounting ¿xture
Single hole mounting tool
Terminating resistor 1.8 K / 0.5 W
904701
800034
800388
675235
Connection / mounting
PT1000 sensor
A1, A2, B, C, D, E, F, G,
indices S, R
0 °C to +400 °C
(+32 °F to +752 °F)
7.6 V - 30 V DC
Response classes
Optional accessories
approx. 15 mA
1 red LED
1 green LED, Àashing
Connection cable standard detector
2-lead
Additional fault line connection
2-lead
External indication
2-lead
Recommended cable
JY (St) Y 2x2x0.8 mm (0.03 inch)
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Note
The desired length of the sensor rod must be speci¿ed in
millimetres at the time of placing the order. Alternatively,
¿xed standard rod lengths are available to choose from.
The detector will be delivered with two Ex cable glands.
These cable glands have to be used at the base.
approx. 15 mA
1 yellow LED (2nd line)
-20 °C to +80 °C
(-4 °F to +176 °F)
IP 67
Diecast aluminium
0 to 95%
no condensation
EN 54 Part 5
520 to 1600 g (1.2 to 3.5 lbs)
130 x 150 to 1500 mm (dia. x H)
5.1 x 5.9 to 59.1 inch (dia. x H)
Approvals / marking
Ex conformity in acc. with 94/9/EC:
x II 3G Ex nA II T4
x II 3D Ex tD A22 IP65 T110°C
Type examination certi¿cate:
BVS 07 ATEX E 157
Ex conformity Russia in acc. with TP TC 012/2011:
2Ex nAc IIC T4
Ex tc IIIC T110°C IP65
G 207091
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
0786-CPD-20281
Chapter 6 - 24
Product Sheet | Detecon
Industrial detectors
UniVario High temperature heat detector FS, Ex
WMX5000 FS 3GD 400 °C 200 mm
(752 °F 7.9 inch)
Order no.: 907281
With ¿xed rod length of 200 mm (7.9 inch).
Otherwise like Order no.: 907270
Technical specifications
Response temperatures
Weight
Dimensions
0 °C to +400 °C
(+32 °F to +752 °F)
680 g (1.5 lbs)
130 x 260 mm (dia. x H)
5.1 x 10.2 inch (dia. x H)
WMX5000 FS 3GD 400 °C 400 mm
(752 °F 15.8 inch)
Order no.: 907282
With ¿xed rod length of 400 mm (15.8 inch).
Otherwise like Order no.: 907270
Technical specifications
Response temperatures
Weight
Dimensions
0 °C to +400 °C
(+32 °F to +752 °F)
840 g (1.9 lbs)
130 x 460 mm (dia. x H)
5.1 x 18.1 inch (dia. x H)
WMX5000 FS 3GD 400 °C 600 mm
(752 °F 23.6 inch)
Order no.: 907283
With ¿xed rod length of 600 mm (23.6 inch).
Otherwise like Order no.: 907270
Technical specifications
Response temperatures
Weight
P31.312.140en / 01.14
Dimensions
0 °C to +400 °C
(+32 °F to +752 °F)
1000 g (2.2 lbs)
130 x 660 mm (dia. x H)
5.1 x 26 inch (dia. x H)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 6 - 25
Product Sheet | Detecon
Industrial detectors
UniVario High temperature heat detector FS, Ex
WMX5000 FS Ex 400°C
Order no.: 912108
The WMX5000 FS Ex high temperature heat detectors
are ATEX- and IEC approved for category 2 gas and 1,
2 dust, and are suitable for use in Ex zones 1, 20 and
21. They have been specially designed for operation in
industrial environments with aggressive media and very high
application temperatures in the monitoring area. For example
in exhaust ducts, engine test stands or machine tools.
In addition to stated temperature detection, rapid rises
in temperature can also be registered by the rate-of-rise
method, for early ¿re detection.
Equipped for operation as a conventional detector. Extension
to a detector with Loop AP protocol via the KMX5000 AP Ex
communication module.
Product features
•
•
•
•
•
Robust stainless steel heat rod sensor.
Freely con¿gurable response temperatures and classes
in accordance with EN54-5, along with rate-of-rise and
static responses. Con¿guration via DIP switches on the
detector or SMX5000 service device.
Service interface, history memory.
Connection of remote indicator possible.
For use in Ex zones 1, 20 and 21, Atex category 3 Gas/
1, 2 Dust.
Technical specifications
Detection method
Operating voltage
PT1000 sensor
A1, A2, B, C, D, E, F, G,
indices S, R
0 °C to +400 °C
(+32 °F to +752 °F)
7.6 V - 30 V DC
Quiescent current
approx. 2.8 mA
Alarm current consumption
approx. 15 mA
Response classes
Response temperatures
Alarm indication
Normal operation indication
Current consumption
Fault indication
Fault indication
Operating temperature
IP rating (EN 60529)
Enclosure material
Relative humidity
(IEC721-3-3)
Speci¿cation according to
P31.312.140en / 01.14
Weight
Dimensions
1 red LED
1 green LED, Àashing
approx. 15 mA
1 yellow LED (2nd line)
-25 °C to +80 °C
(-13 °F to +176 °F)
IP 67
Diecast aluminium
0 to 95%
no condensation
EN 54 Part 5
520 to 1600 g (1.2 to 3.5 lbs)
130 x 150 to 1500 mm (dia. x H)
5.1 x 5.9 to 59.1 inch (dia. x H)
Optional accessories
Safety barrier IS conventional 9 V
Safety barrier IS addressable 24 V
KMX5000 AP Ex communication module
Weather protection MX5000 complete
Silicone-free design
904991
901324
912086
910134
Not included in delivery
Base UniVario MX5000 Ex
Single hole mounting ¿xture
Single hole mounting tool
Terminating resistor 1.8 K / 0.5 W
912082
800034
800388
675235
Connection / mounting
Connection cable standard detector
2-lead
Additional fault line connection
2-lead
External indication
2-lead
Recommended cable
JY (St) Y 2x2x0.8 mm (0.03 inch)
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Note
The desired length of the sensor rod must be speci¿ed in
millimetres at the time of placing the order. Alternatively,
¿xed standard rod lengths are available to choose from.
Approvals / marking
Ex conformity in acc. with 94/9/EC:
x II 2G Ex ia IIC T6/T4 Gb
x II 1D Ex ia IIIC T95°C Da
Type examination certi¿cate:
BVS 12 ATEX E120
IECEx conformity:
IECEx BVS 12.0073
Ex conformity Russia in acc. with TP TC 012/2011:
1Ex ia IIC T6/T4 Gb
0Ex ia IIC T6/T4 Ga
Ex ia IIIC T95°C Da
G 207091
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
0786-CPD-20281
Chapter 6 - 26
Product Sheet | Detecon
Industrial detectors
UniVario High temperature heat detector FS, Ex
WMX5000 FS Ex 400 °C 200 mm
(752 °F 7.9 inch)
Order no.: 912110
With ¿xed rod length of 200 mm (7.9 inch).
Otherwise like Order no.: 912108
Technical specifications
Response temperatures
Weight
Dimensions
0 °C to +400 °C
(+32 °F to +752 °F)
680 g (1.5 lbs)
130 x 260 mm (dia. x H)
5.1 x 10.2 inch (dia. x H)
WMX5000 FS Ex 400 °C 400 mm
(752 °F 15.8 inch)
Order no.: 912111
With ¿xed rod length of 400 mm (15.8 inch).
Otherwise like Order no.: 912108
Technical specifications
Response temperatures
Weight
Dimensions
0 °C to +400 °C
(+32 °F to +752 °F)
840 g (1.9 lbs)
130 x 460 mm (dia. x H)
5.1 x 18.1 inch (dia. x H)
WMX5000 FS Ex 400 °C 600 mm
(752 °F 23.6 inch)
Order no.: 912112
With ¿xed rod length of 600 mm (23.6 inch).
Otherwise like Order no.: 912108
Technical specifications
Response temperatures
Weight
P31.312.140en / 01.14
Dimensions
0 °C to +400 °C
(+32 °F to +752 °F)
1000 g (2.2 lbs)
130 x 660 mm (dia. x H)
5.1 x 26 inch (dia. x H)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 6 - 27
Product Sheet | Detecon
Industrial detectors
UniVario High temperature heat detector FS Flex, Ex
WMX5000 FS Flex 3GD 400°C (752 °F)
Order no.: 907284
The WMX5000 FS 3GD high temperature heat detectors
are ATEX-approved for category 3, gas and dust, and are
suitable for use in Ex zones 2 and 22. They have been
specially designed for operation in industrial environments
with aggressive media and very high application
temperatures in the monitoring area. For example in exhaust
ducts, engine test stands or machine tools.
In addition to stated temperature detection, rapid rises
in temperature can also be registered by the rate-of-rise
method, for early ¿re detection.
Designed for operation as a conventional detector.
Expansion to a detector with Loop AP protocol via the
KMX5000 AP communications module.
Product features
Optional accessories
•
Robust Àexible stainless steel heat sensor.
•
Freely con¿gurable response temperatures and classes
in accordance with EN54-5, along with rate-of-rise and
static responses. Con¿guration via DIP switches on the
detector or SMX5000 service device.
Parallel indicator
KMX5000 AP communication module
Silicone-free design
•
Service interface, history memory.
•
Connection of remote indicator possible.
•
For use in Ex zones 2 and 22, Atex category 3, Gas/Dust.
908499
905883
Not included in delivery
Base UniVario MX5000
Holder WMX FS, from
250 °C (482 °F) to 600 °C (1112 °F)
Terminating resistor 1.8 K / 0.5 W
904701
894679
675235
Connection / mounting
Technical specifications
Detection method
Operating voltage
PT1000 sensor
A1, A2, B, C, D, E, F, G,
indices S, R
0 °C to +400 °C
(+32 °F to +752 °F)
7.6 V - 30 V DC
Quiescent current
approx. 0.25 mA
Response classes
Response temperatures
Alarm current consumption
Alarm indication
Normal operation indication
Current consumption
Fault indication
Fault indication
Operating temperature
IP rating (EN 60529)
P31.312.160en / 02.14
Enclosure material
Relative humidity
(IEC721-3-3)
Speci¿cation according to
Weight
Dimensions
approx. 15 mA
1 red LED
1 green LED, Àashing
approx. 15 mA
1 yellow LED (2nd line)
-20 °C to +80 °C
(-4 °F to +176 °F)
IP 67
Diecast aluminium
0 to 95%
no condensation
EN 54 Part 5
520 to 1600 g (1.2 to7.5 lbs)
130 x 2000 to 9000 mm (dia. x H)
5.1 x 78.7 x 354.3 inch (dia. x H)
Connection cable standard detector
2-lead
Additional fault line connection
2-lead
External indication
2-lead
Recommended cable
JY (St) Y 2x2x0.8 mm (0.03 inch)
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Note
The desired length of the Àexible sensor must be speci¿ed in
metres at the time of placing the order.
The sensor rod holder is designed for operation temperatures
of up to 250 °C (482 °F). For higher operation temperatures,
the WMX FS holder from 250 °C (482 °F) to 600 °C (1112 °F)
Order no. 894679 is to be used.
The detector will be delivered with two Ex cable glands.
These cable glands have to be used at the base.
Approvals / marking
Ex conformity in acc. with 94/9/EC:
x II 3G Ex nA II T4
x II 3D Ex tD A22 IP65 T110°C
Type examination certi¿cate:
BVS 07 ATEX E 157
Ex conformity Russia in acc. with TP TC 012/2011:
2Ex nAc IIC T4
Ex tc IIIC T110°C IP65
G 207091
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
0786-CPD-20281
Chapter 6 - 28
Product Sheet | Detecon
Industrial detectors
UniVario High temperature heat detector FS Flex, Ex
WMX5000 FS Flex 3GD 400 °C 2 m
(752 °F 79 inch)
Order no.: 907285
Version with Àexible hose of 2 m length (79 inch).
Otherwise like Order no.: 907284
Technical specifications
Response temperatures
Weight
Dimensions
0 °C to +400 °C
(+32 °F to +752 °F)
680 g (1.5 lbs)
130 x up to 2000 mm (dia. x H)
5.1 x up to 78.73 inch (dia. x H)
WMX5000 FS Flex 3GD 400 °C 6 m
(752 °F 236 inch)
Order no.: 907286
Version with Àexible hose of 6 m length (236 inch).
Otherwise like Order no.: 907284
Technical specifications
Response temperatures
Weight
Dimensions
0 °C to +400 °C
(+32 °F to +752 °F)
840 g (1.9 lbs)
130 x up to 6000 mm (dia. x H)
5.1 x up to 236.2 inch (dia. x H)
WMX5000 FS Flex 3GD 400 °C 9 m
(752 °F 354 inch)
Order no.: 907287
Version with Àexible hose of 9 m length (354 inch).
Otherwise like Order no.: 907284
Technical specifications
Response temperatures
Weight
P31.312.160en / 02.14
Dimensions
0 °C to +400 °C
(+32 °F to +752 °F)
1000 g (2.2 lbs)
130 x up to 9000 mm (dia. x H)
5.1 x up to 354.3 inch (dia. x H)
WMX5000 FS Flex 3GD 400 °C
(752 °F) CN
Order no.: 909387
Approvals / marking
Version China
Otherwise like Order no.: 907284
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 6 - 29
Product Sheet | Detecon
Industrial detectors
UniVario High temperature heat detector FS Flex, Ex
WMX5000 FS Flex Ex 400°C
Order no.: 912113
The WMX5000 FS Ex high temperature heat detectors
are ATEX and IEC approved for category 2 gas and 1,
2 dust, and are suitable for use in Ex zones 1, 20 and
21. They have been specially designed for operation in
industrial environments with aggressive media and very high
application temperatures in the monitoring area. For example
in exhaust ducts, engine test stands or machine tools.
In addition to stated temperature detection, rapid rises
in temperature can also be registered by the rate-of-rise
method, for early ¿re detection.
Designed for operation as a conventional detector.
Expansion to a detector with Loop AP protocol via the
KMX5000 AP Ex communications module.
Optional accessories
Product features
Robust Àexible stainless steel heat sensor.
•
Freely con¿gurable response temperatures and classes
in accordance with EN54-5, along with rate-of-rise and
static responses. Con¿guration via DIP switches on the
detector or SMX5000 service device.
•
Service interface, history memory.
Not included in delivery
•
For use in Ex zones 1, 20 and 21, Atex category 2,
Gas/1,2 Dust.
Base UniVario MX5000 Ex
Holder WMX FS, from
250 °C (482 °F) to 600 °C (1112 °F)
Terminating resistor 1.8 K / 0.5 W
Technical specifications
Detection method
Operating voltage
PT1000 sensor
A1, A2, B, C, D, E, F, G,
indices S, R
0 °C to +400 °C
(+32 °F to +752 °F)
7.6 V - 28 V DC
Quiescent current
approx. 2.8 mA
Alarm current consumption
approx. 15 mA
Response classes
Response temperatures
Alarm indication
Normal operation indication
Current consumption
Fault indication
Fault indication
Operating temperature
IP rating (EN 60529)
Enclosure material
Relative humidity
(IEC721-3-3)
Speci¿cation according to
Weight
P31.312.160en / 02.14
Safety barrier IS conventional 9 V
Safety barrier IS addressable 24 V
KMX5000 AP Ex communication module
Weather protection MX5000 complete
Silicone-free design
•
Dimensions
1 red LED
1 green LED, Àashing
approx. 15 mA
1 yellow LED (2nd line)
-25 °C to +80 °C
(-13 °F to +176 °F)
IP 67
Diecast aluminium
0 to 95%
No condensation
EN 54 Part 5
520 to 1600 g (1.2 to7.5 lbs)
130 x 2000 to 9000 mm (dia. x H)
5.1 x 78.7 x 354.3 inch (dia. x H)
904991
901324
912086
910134
912082
894679
675235
Connection / mounting
Connection cable standard detector
2-lead
Additional fault line connection
2-lead
External indication
2-lead
Recommended cable
JY (St) Y 2x2x0.8 mm (0.03 inch)
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Note
The desired length of the Àexible sensor must be speci¿ed in
metres at the time of placing the order.
The sensor rod holder is designed for operation temperatures
of up to 250 °C (482 °F). For higher operation temperatures,
the WMX FS holder from 250 °C (482 °F) to 600 °C (1112 °F)
Order no. 894679 is to be used.
Approvals / marking
Ex conformity in acc. with 94/9/EG:
x II 2G Ex ia IIC T6/T4 Gb
x II 1D Ex ia IIIC T95°C Da
Type examination certi¿cate:
BVS 12 ATEX E120
IECEx conformity:
IECEx BVS 12.0073
Ex conformity Russia in acc. with TP TC 012/2011:
1Ex ia IIC T6/T4 Gb
0Ex ia IIC T6/T4 Ga
Ex ia IIIC T95°C Da
G 207091
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
0786-CPD-20281
Chapter 6 - 30
Product Sheet | Detecon
Industrial detectors
UniVario High temperature heat detector FS Flex, Ex
WMX5000 FS Flex 3GD 400 °C 2 m
(752 °F 79 inch)
Order no.: 912114
Version with Àexible hose of 2 m length (79 inch).
Otherwise like Order no.: 912113
Technical specifications
Response temperatures
Weight
Dimensions
0 °C to +400 °C
(+32 °F to +752 °F)
680 g (1.5 lbs)
130 x up to 2000 mm (dia. x H)
5.1 x up to 78.73 inch (dia. x H)
WMX5000 FS Flex 3GD 400 °C 6 m
(752 °F 236 inch)
Order no.: 912115
Version with Àexible hose of 6 m length (236 inch).
Otherwise like Order no.: 912113
Technical specifications
Response temperatures
Weight
Dimensions
0 °C to +400 °C
(+32 °F to +752 °F)
840 g (1.9 lbs)
130 x up to 6000 mm (dia. x H)
5.1 x up to 236.2 inch (dia. x H)
WMX5000 FS Flex 400 °C 9 m
(752 °F 354 inch)
Order no.: 912116
Version with Àexible hose of 9 m length (354 inch).
Otherwise like Order no.: 912113
Technical specifications
Response temperatures
Weight
P31.312.160en / 02.14
Dimensions
0 °C to +400 °C
(+32 °F to +752 °F)
1000 g (2.2 lbs)
130 x up to 9000 mm (dia. x H)
5.1 x up to 354.3 inch (dia. x H)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 6 - 31
Product Sheet | Detecon
Industrial detectors
UniVario Detector accessories
KMX5000 AP communication module
Order no.: 905883
Communication module for the operation of UniVario
detectors on ¿re alarm panels with Loop AP protocol.
By simply plugging the module into the detector, a
conventional detector is turned into an analogue addressable
detector. The detector address is set via a DIP switch. Power
supply and communications are connected via the ring bus;
no additional power supply is required.
The KMX5000 AP communication module is designed for
integration into UniVario series detectors and must not be
used in hazard areas.
Product features
Included in delivery
•
Communication module for constant signalling of
operating condition, alarms and faults via Loop AP
protocol.
1 KMX5000 AP communication module
Pan-head screw and Spacer
•
Ring bus connection, no additional power supply.
Connection / mounting
•
Integration in UniVario series detectors.
Plug-in module in UniVario series detectors
Technical specifications
Connection
10 spring contacts (module/detector)
Operating voltage
17 V - 28 V DC
Operating current
approx. 0,3 mA
Communication protocol
Addressing
Operating temperature
Relative humidity
(IEC721-3-3)
Loop AP
8 position DIP switch
-20 °C to +80 °C
(-4 °F to +176 °F)
5 to 85%
no condensation
Speci¿cation according to
Weight
Dimensions
EN 54 Part 18
15 g (0.03 lbs)
54 x 28 x 19.5 mm (LxWxH)
2.1 x 1.1 x 0.8 inch (LxWxH)
Approvals / marking
0786-CPD-20315
P31.312.810 - 1en / 01.14
G 207032
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 6 - 32
Product Sheet | Detecon
Industrial detectors
UniVario Detector accessories
KMX5000 AP Ex communication module
Order no.: 912086
Communication module for the operation of UniVario
detectors on ¿re alarm panels with Loop AP protocol.
By simply plugging the module into the detector, a
conventional detector is turned into an analogue addressable
detector. The detector address is set via a DIP switch. Power
supply and communications are connected via the ring bus;
no additional power supply is required.
The KMX5000 AP Ex communication module is designed for
integration into UniVario series detectors and may be used in
hazard areas.
Product features
Included in delivery
•
Communication module for constant signalling of
operating condition, alarms and faults via Loop AP
protocol.
1 KMX5000 AP Ex communication module
Pan-head screw and Spacer
•
Ring bus connection, no additional power supply.
Connection / mounting
•
Integration in UniVario Ex series detectors.
Plug-in module in UniVario Ex series detectors
Technical specifications
Connection
10 spring contacts (module/detector)
Operating voltage
14 V - 22 V DC
Operating current
approx. 0,3 mA
Communication protocol
Loop AP
Addressing
8 position DIP switch
-20 °C to +80 °C
(-4 °F to +176 °F)
5 to 85%
no condensation
Operating temperature
Relative humidity
(IEC721-3-3)
Speci¿cation according to
Weight
Dimensions
EN 54 Part 18
15 g (0.03 lbs)
54 x 28 x 19.5 mm (LxWxH)
2.1 x 1.1 x 0.8 inch (LxWxH)
Approvals / marking
Ex conformity Russia in acc. with TP TC 012/2011:
1Ex ib IIC T5/T4 Gb
applied for
P31.312.810 - 1en / 01.14
applied for
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 6 - 33
Product Sheet | Detecon
Industrial detectors
UniVario Detector accessories
Base MX5000
Order no.: 904701
Retaining base for all UniVario industrial ¿re detectors.
Contains cable entries, EMC and environmental seals,
connecting terminals and space for the optional relay module
KMX5000 RK.
Enables replacement of a detector without any terminal work.
Not included in delivery
End of line resistor 1.8 K / 0.5 W
675235
Spare parts
Seal 127 x 2.9 / 1.6 mm
Gland M 16 x 1.5 Ms
Sealing cord 8 mm Vitron 0.036 m
Technical specifications
Material
Aluminium
Relative humidity
Conductor cross-section
max. 100 %
904752
901861
800605
Approvals / marking
max. 2.5 mm2 (0.004 square inch)
Colour
red
-40 °C to +100 °C
(-40 °F to +212 °F)
310 g (0.7 lbs)
Ambient temperature
Weight
Base MX5000 SF
Order no.: 914235
Silicon free base.
Otherwise like Order no. 904701
Base MX5000 3M16
Order no.: 907011
Retaining base for all UniVario industrial ¿re detectors.
Contains cable entries, EMC and environmental seals,
connecting terminals and space for the optional relay module
KMX5000 RK.
The third cable gland allows the interface connection with
detector remote indicators or similar devices.
Not included in delivery
End of line resistor 1.8 K / 0.5 W
675235
Spare parts
Seal 127 x 2.9 / 1.6 mm
Gland M 16 x 1.5 Ms
Sealing cord 8 mm Vitron 0.036 m
Technical specifications
P31.312.810 - 1en / 01.14
Material
Aluminium
Relative humidity
Conductor cross-section
Colour
Ambient temperature
Weight
max. 100 %
max. 2.5 mm (0.004 square inch)
2
Approvals / marking
red
-40 °C to +100 °C
(-40 °F to +212 °F)
350 g (0.8 lbs)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 6 - 34
904752
901861
800605
Product Sheet | Detecon
Industrial detectors
UniVario Detector accessories
Base MX5000 LCD
Order no.: 906127
Base for displaying status and signal messages from
industrial ¿re alarms of the UniVario series.
The LCD display gives information about sensor temperature,
alarms or other operating states, depending on the detector
type. Includes cable entries, EMC and environmental seals
and connecting terminals.
Enables replacement of a detector without any terminal work.
The LCD base must not be used in hazard areas.
Not included in delivery
End of line resistor 1.8 K / 0.5 W
Spare parts
Technical specifications
Operating voltage
By means of the detector
Operating current
0.3 mA
Material
Aluminium
Relative humidity
Conductor cross-section
675235
max. 100 %
Seal 127 x 2.9 / 1.6 mm
Gland M 16 x 1.5 Ms
Sealing cord 8 mm Vitron 0.036 m
904752
901861
800605
Approvals / marking
max. 2.5 mm2 (0.004 square inch)
Colour
red
-20 °C to +70 °C
(-4 °F to +158 °F)
350 g (0.8 lbs)
Ambient temperature
Weight
Base MX5000-I
Order no.: 912493
Detector base for installation of the UniVario industrial ¿re
detectors in the LoopAP ringbus.
Contains cable inlets, EMC and environmental sealing as
well as terminals.
Not suitable for use in explosion-prone areas.
The installed dual isolator increases the operational safety of
the LoopAP ringbus in the event of a short-circuit.
The third cable screw connection is available for connecting
detector mimic panels or similar devices.
Spare parts
Seal 127 x 2.9 / 1.6 mm
Gland M 16 x 1.5 Ms Ex
Sealing cord 8 mm Vitron 0.036 m
Technical specifications
Material
Aluminium
P31.312.810 - 1en / 01.14
Relative humidity
Conductor cross-section
Colour
Ambient temperature
Weight
max. 100 %
max. 2.5 mm (0.004 square inch)
2
red
-20 °C to +80 °C
(-4 °F to +176 °F)
530 g (1.2 lbs)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 6 - 35
904752
904652
800605
Product Sheet | Detecon
Industrial detectors
UniVario Detector accessories
Base MX5000 Ex
Order no.: 912082
Detector base for installation of the UniVario industrial ¿re
detectors of the Ex series. Contains cable inlets, EMC and
environmental sealing as well as terminals.
In this way, detectors can be replaced without requiring connecting work.
Not included in delivery
End of line resistor 1.8 K / 0.5 W
675235
Spare parts
Seal 127 x 2.9 / 1.6 mm
Gland M 16 x 1.5 Ms Ex
Sealing cord 8 mm Vitron 0.036 m
Technical specifications
Material
904752
904652
800605
Aluminium
Relative humidity
Conductor cross-section
max. 100 %
max. 2.5 mm2 (0.004 square inch)
Colour
Ambient temperature
Weight
red
-40 °C to +100 °C
(-40 °F to +212 °F)
530 g (1.2 lbs)
Bracket MX5000
Approvals / marking
Ex conformity Russia in acc. with TP TC 012/2011:
1Ex ib IIC T5/T4 Gb
Order no.: 904757
Mounting bracket for UniVario MX5000 base.
Included in delivery
1 bracket UniVario MX5000
2 x screws M8, hex socket size 5 mm (0.2 inch).
Not included in delivery
Mounting screws for wall/ceiling-mounted installation.
Technical specifications
Material
Bracket retention
P31.312.810 - 1en / 01.14
Weight
Spare parts
Stainless steel, 2 mm
(0.08 inch) thick
Plastic (POM), black
Screw M 8
904355
110 g (0.2 lbs)
Bracket MX5000 SF
Order no.: 914234
Silicon free bracket.
Otherwise like Order no. 904757
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 6 - 36
Product Sheet | Detecon
Industrial detectors
UniVario Detector accessories
Isolator ISX 284 3GD
Order no.: 915864
Isolator XP and DIS for the separation of individual line sections in the event of short circuits in ring bus operation with
approval for ATEX category 3 gas and dust. Are suitable for
use in Ex zones 2 and 22.
Approvals / marking
Technical specifications
Material
Aluminium
Fault indication inside
IP rating (EN60529)
Colour
Ambient temperature
Weight
x II 2G Ex d IIB T6 Gb
x II 2D Ex tb IIIC T80°C Db
Yellow LED
IP 66
EC type approval certi¿cate:
grey
-20 °C to +60 °C
(-4 °F to +140 °F)
1.2 kg
(2.6 lbs)
90 mm (dia.)
3.5 inch (dia.)
P31.312.810 - 1en / 01.14
Dimensions
Ex conformity in acc. with 94/9/EG:
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 6 - 37
BVS 11 ATEX E114
Product Sheet | Detecon
Industrial detectors
UniVario Detector accessories
Relay module KMX5000 RK
Order no.: 906361
Communication module for the operation of UniVario
detectors, independent of any ¿re detection system.
Dry contacts for alarm and fault signalling allow the detectors
to be used as stand-alone units, in any ¿re and hazard
detection system or in building management and control
systems.
The KMX5000 RK communication module is designed to be
integrated into the UniVario detector base MX5000 and must
not be used in hazard areas.
Product features
Included in delivery
•
•
Relay module KMX5000 RK
Jumper
Installation material
Dry changeover contacts for alarm and fault signalling.
Integration into MX5000 detector base.
Technical specifications
Connection
Operating voltage
Quiescent current
Current consumption with
alarm relay active
Current consumption with
alarm relay and fault relay
active
Voltage load,
contacts
Current load, contacts
Fault indication
Operating temperature
Relative humidity
(IEC721-3-3)
6-conductor ribbon cable
24 V (14 V - 29 V) DC
Dimensions
Conductor cross-section
approx. 7 mA
min. 0.5 mm2 (0.0008 square inch)
Max. 2.5 mm2 (0.004 square inch)
approx. 20 mA
approx. 30 mA
Max. 60 V DC, 25 V AC
max. 1 A
1 yellow LED (2nd line)
-20 °C to +80 °C
(-4 °F to +176 °F)
5 to 85%
no condensation
Speci¿cation according to
Weight
Connection / mounting
EN 54 Part 18
50 g (0.1 lbs)
64 x 24 x 57 mm (LxWxH)
2.5 x 0.9 x 2.2 inch (LxWxH)
Approvals / marking
0786-CPD-20314
P31.312.810 - 1en / 01.14
G 208058
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 6 - 38
Product Sheet | Detecon
Industrial detectors
UniVario Detector accessories
Console MX5000 Flame detector
Order no.: 904758
Console for the installation of UniVario Àame detectors
outside of monitored areas, e.g. air ducts, machine tools,
containers or silos.
Easy access to the detector. Bayonet socket for reliable,
vibration-proof hold.
Antistatic material for use in hazard areas up to zones 1 and
21.
Included in delivery
Technical specifications
Material
Dimensions
Colour
Ambient temperature
Weight
PA6 99/0701 EC
138 x 15 mm (WxH)
6.6 x 0.6 inch (WxH)
Black
-20 °C to +100 °C
(-4 °F to +212 °F)
145 g (0.3 lbs)
Console MX5000 Heat detector
Mount with Àat sealing and springs
Screw M5
Self-tapping screw
Blind rivets
O-ring
Installation drawing
906148
904341
765233
885078
904759
906970
Order no.: 906969
Console for the installation of UniVario heat detectors on
e.g. air ducts, dryers or machine tools.
Easy access to the detector. Bayonet socket for reliable,
vibration-proof hold.
Antistatic material for use in hazard areas up to zones 1 and
21.
Included in delivery
Technical specifications
Material
Dimensions
Colour
P31.312.810 - 1en / 01.14
Ambient temperature
Weight
PA6 99/07001 EC
138 x 16.2 mm (WxH)
5.4 x 0.6 inch (WxH)
Black
-20 °C to +100 °C
(-4 °F to +212 °F)
145 g (0.3 lbs)
Console with Àat sealing and springs
Screw M5
Self-tapping screw
Blind rivets
O-ring
Installation drawing
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 6 - 39
906148
904341
765233
885078
904759
906970
Product Sheet | Detecon
Industrial detectors
UniVario Detector accessories
Weather protection MX5000 complete
Order no.: 910134
Additional equipment – weather protection for Àame detectors of the Uni Vario series for use in case of increased solar
radiation or exposure to harsh weather conditions.
Connection / mounting
Fasten the weather protection to the detector.
Technical specifications
Colour
Stainless steel, 0.5 mm (0.02 inch)
thick
140 x 110 x 220 mm (BxHxL)
5.5 x 4.3 x 8.7 inch (BxHxL)
internally black
Weight
300 g (0.67 lbs)
Material
P31.312.810 - 1en / 01.14
Dimensions
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 6 - 40
Product Sheet | Detecon
Industrial detectors
UniVario Test equipment
Service device SMX5000
Order no.: 906136
The service device is for the simpli¿ed con¿guration,
diagnostics and function testing of the UniVario detectors,
and for indicating events from the history memory.
The SMX5000 can be used on UniVario detectors with
software version V01 Exx or higher.
An RS-232 interface can be used to transmit data from the
history memory to the UniVario View software.
Product features
Included in delivery
•
•
•
1 service device SMX5000
1 connection cable, 30-pin
2 1.5 V batteries, type AA (LR6)
Display with 3 rows of 12 characters each.
Simple operation with clear menu structure.
Operation and fault indication.
Accessories
Technical specifications
LCD display
Operating current
(depends on the detector type)
Operation time
(depends on the detector
and battery types)
Batteries required
IP rating
3 rows of 12 characters each
approx. 80 mA at 3 V
(with background lighting)
approx. 25 mA at 3 V
(without background lighting)
approx. 5 mA at 3 V
(in detector mode)
approx. 25 hrs
(with background lighting)
approx. 80 hrs
(without background lighting)
approx. 400 hrs
(in detector mode)
2 x 1.5 V Mignon, type AA (LR6)
Battery 1.5 V Mignon, type AA (LR6)
Connection cable, 30-pin
Not included in delivery
UniVario View software
IP 20
Enclosure material
Operating temperature
Relative humidity
(IEC721-3-3)
Speci¿cation according to
Weight
Dimensions
ABS plastic, RAL 7038 grey
0 °C to +50 °C
(-32 °F to +122 °F)
5 to 85%
no condensation
EN 55022/CISPR22 CL. B,
EN 55024, EN 61000-6-3,
EN 61000-4-2, EN 61000-4-3,
26 g (0.1 lbs)
165 x 92 x 30 mm (LxWxH)
6.5 x 3.6 x 1.2 inch (LxWxH)
P31.312.911en / 02.13
Approvals / marking
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 6 - 41
906751
906198
Product Sheet | Detecon
Industrial detectors
IR flame detector
FMX3511
Order no.: 801618
Double infrared Àame detector FMX3511 for the detection
of open Àames. Optic test monitors the functionality of the
detector.
Designed for use in raugh industrial environments. Equipped
for operation as a conventional detector.
Product features
Not included in delivery
•
Highly reliable against false alarms, e.g. from hot surfaces.
•
A microcontroller monitors the functionality. Faults can
be indicated on the detector or on a separate line.
•
Connection of remote indicator possible.
Mounting device bracket with insulation
Mounting device console 125x80Ø60
End of line-resistor 1.8 K / 0.5 W
Sun screen
Parallel indicator LMX5000
Plug for the pollution test
•
Single optic test.
801284
801280
675235
801277
908499
801079
Connection / mounting
Connection cable standard detector
2-lead
Recommended cable LiYCY 5x0.5 mm2 (0.0008 square inch)
Cable gland
M16x1.5, Brass nickel-plated, EMV
Technical specifications
Detection method
Sensitivity class
Viewing angle
3
7.6 V - 15 V DC
Quiescent current
approx. 3 mA
Alarm indication
Fault indication
1 LED yellow
Operating temperature
IP rating (EN 60529)
Enclosure material
Relative humidity
(IEC721-3-3)
Weight
Dimensions
0786-CPD-20312
1 LED red
approx. 7 mA
Electrostatic shielding
G 296016
approx. 18 mA
Fault indication current
Number of detectors per line
Approvals / marking
60 °
Operating voltage
Alarm current
P31.312.330 - 3en / 02.13
2 IR Sensoren
max. 4
Required
-25 °C to +80 °C
(-13 °F to +176 °F)
IP 65
Diecast aluminium,
RAL5009-blue
max. 100% at + 35 °C (+95 °F)
600 g (1.3 lbs)
127 x 125 x 70 mm (BxHxT)
5 x 4.9 x 2.8 inch (BxHxT)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 6 - 42
Product Sheet | Detecon
Industrial detectors
IR flame detector
FMX3511 SF
Order no.: 801619
Silicone-free Àame detector
FMX3511 0.2 sec
Order no.: 902532
Flame detectors with fast response within range of milsecounds are used for object monitoring (e.g. tooling machine).
Technical specifications
Criterion of detection
FMX3511 0.2 sec SF
Change of intensity
Order no.: 902767
P31.312.330 - 3en / 02.13
Silicone-free Àame detector
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 6 - 43
Product Sheet | Detecon
Industrial detectors
IR flame detector
FMX3511 BG
Order no.: 891319
Double infrared Àame detector FMX3511 for the detection
of open Àames. Optic test monitors the functionality of the
detector.
Designed for use in raugh industrial environments. Equipped
for operation as a conventional detector.
Product features
Not included in delivery
•
Highly reliable against false alarms, e.g. from hot surfaces.
•
A microcontroller monitors the functionality. Faults can
be indicated on the detector or on a separate line.
End of line-resistor 1.8 K / 0.5 W
Sun sreen
Parallel indicator LMX5000
Plug for the pollution test
•
Connection of remote indicator possible.
•
Single optic test.
Connection /mounting
Connection cable standard detector
2-lead
Recommended cable LiYCY 5x0.5 mm2 (0.0008 square inch)
Cable gland
M16x1.5, brass nickel-plated, EMV
Technical specifications
Detection method
Sensitivity class
Viewing angle
Operating voltage
Quiescent current
Alarm current
Alarm indication
3
Enclosure material
Relative humidity
(IEC721-3-3)
Weight
Dimensions
0786-CPD-20312
approx. 3 mA
approx. 18 mA
1 LED red
1 LED yellow
IP rating (EN 60529)
G 296016
7.6 V - 15 V DC
Fault indication
Operating temperature
Approvals / marking
60 °
approx. 7 mA
Electrostatic shielding
P31.312.330 - 4en / 02.13
2 IR Sensoren
Fault indication current
Number of detectors per line
675235
801277
908499
801079
max. 4
Required
-25 °C to +80 °C
(-13 °F to +176 °F)
IP 65
Diecast aluminium,
RAL5009-blue
max. 100% at + 35 °C (+95 °F)
750 g (1.7 lbs)
127 x 155 x 92 mm (BxHxT)
5 x 6.1 x 3.6 inch (BxHxT)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 6 - 44
Product Sheet | Detecon
Industrial detectors
IR flame detector
FMX3511 BG SF
Order no.: 800029
Silicone-free Àame detector
FMX3511 BG 0.2 sec
Order no.: 902533
Flame detectors with fast response within range of miliseconds are used for object monitoring (e.g. tooling machine).
Technical specifications
Criterion of detection
FMX3511 BG 0.2 sec SF
Change of intensity
Order no.: 902768
P31.312.330 - 4en / 02.13
Silicone-free Àame detector
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 6 - 45
Product Sheet | Detecon
Industrial detectors
IR flame detector
FMX3511 Console
Order no.: 801609
Double infrared Àame detector FMX3511 for the detection
of open Àames. Optic test monitors the functionality of the
detector. Version Brachet mounting.
Designed for use in rough industrial environments. Equipped
for operation as a conventional detector.
Product features
Not included in delivery
•
Highly reliable against false alarms, e.g. from hot surfaces.
•
A microcontroller monitors the functionality. Faults can
be indicated on the detector or on a separate line.
•
Connection of remote indicator possible.
Mounting device bracket with insulation
End of line-resistor 1.8 K / 0.5 W
Sun sreen
Parallel indicator LMX5000
Plug for the pollution test
•
Single optic test.
Connection / mounting
Connection cable standard detector
2-lead
Recommended cable LiYCY 5x0.5 mm2 (0.0008 square inch)
Cable gland
M16x1.5, brass nickel-plated, EMV
Technical specifications
Detection method
Sensitivity class
Viewing angle
3
60 °
7.6 V - 15 V DC
Quiescent current
approx. 3 mA
Alarm indication
Fault indication
1 LED yellow
Operating temperature
IP rating (EN 60529)
Enclosure material
Relative humidity
(IEC721-3-3)
Weight
Dimensions
G 296016
0786-CPD-20312
1 LED red
approx. 7 mA
Electrostatic shielding
Approvals / marking
approx. 18 mA
Fault indication current
Number of detectors per line
P31.312.330 - 5en / 02.13
2 IR Sensoren
Operating voltage
Alarm current
801284
675235
801277
908499
801079
max. 4
Required
-25 °C to +80 °C
(-13 °F to +176 °F)
IP 65
Diecast aluminium,
RAL5009-blue
max. 100% at + 35 °C (+95 °F)
950 g (2.1 lbs)
127 x 150 x 75 mm (BxHxT)
5 x 5.9 x 3 inch (BxHxT)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 6 - 46
Product Sheet | Detecon
Industrial detectors
IR flame detector
FMX3511 Console 0.2 sec
Order no.: 902534
Flame detectors with fast response within range of miliseconds are used for object monitoring (e.g. tooling machine).
Technical specifications
Change of intensity
P31.312.330 - 5en / 02.13
Criterion of detection
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 6 - 47
Product Sheet | Detecon
Industrial detectors
IR flame detector
FMX3511 Console LSP
Order no.: 801610
Double infrared Àame detector FMX3511 for the detection
of open Àames. Optic test monitors the functionality of the
detector. Version Brachet mounting and air Àushing function.
Designed for use in rough industrial environments. Equipped
for operation as a conventional detector.
Product features
Not included in delivery
•
Highly reliable against false alarms, e.g. from hot surfaces.
•
A microcontroller monitors the functionality. Faults can
be indicated on the detector or on a separate line.
•
Connection of remote indicator possible.
Mounting device bracket with insulation
End of line-resistor 1.8 K / 0.5 W
Sun sreen
Parallel indicator LMX5000
Plug for the pollution test
Compressed air supply
•
Single optic test.
801284
675235
801277
908499
801079
Connection / mounting
Connection cable standard detector
2-lead
Recommended cable LiYCY 5x0.5 mm2 (0.0008 square inch)
Cable gland
M16x1.5, brass nickel-plated, EMV
Technical specifications
Detection method
Sensitivity class
Viewing angle
3
7.6 V - 15 V DC
Quiescent current
approx. 3 mA
Alarm indication
Fault indication
1 LED yellow
Operating temperature
IP rating (EN 60529)
Enclosure material
Relative humidity
(IEC721-3-3)
Weight
Dimensions
Compressed air
supply on site
0786-CPD-20312
1 LED red
approx. 7 mA
Electrostatic shielding
G 296016
approx. 18 mA
Fault indication current
Number of detectors per line
Approvals / marking
60 °
Operating voltage
Alarm current
P31.312.330 - 6en / 02.13
2 IR Sensoren
max. 4
Required
-25 °C to +80 °C
(-13 °F to +176 °F)
IP 65
Diecast aluminium,
RAL5009-blue
max. 100% at +35 °C (+95 °F)
970 g (2.1 lbs)
141 x 150 x 75 mm (BxHxT)
5.6 x 5.9 x 3 inch (BxHxT)
Pressure range 0.8 - 1.5 bar
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 6 - 48
Product Sheet | Detecon
Industrial detectors
IR flame detector
FMX3511 Console LSP 0.2 sec
Order no.: 902535
Flame detectors with fast response within range of miliseconds are used for object monitoring (e.g. tooling machine).
Technical specifications
Change of intensity
P31.312.330 - 6en / 02.13
Criterion of detection
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 6 - 49
Product Sheet | Detecon
Industrial detectors
IR flame detector Ex
FMX3501 Ex
Order no.: 903133
Infrared Àame detector FMX3501 Ex for the detection of open
Àames. Optic test monitors the functionality of the detector.
Designed for use in rough industrial environments. Equipped
for operation as a conventional detector.
Infrared Àame detector FMX3501 Ex are ATEX-approved
for category 2 gas and 3 dust and are suitable for use in Ex
zones 1 and 22.
Intrinsically safe Àame detectors must be connected by correspondingly marked cables to explosion hazard barriers.
Product features
Not included in delivery
•
Highly reliable against false alarms, e.g. from hot surfaces.
•
A microcontroller monitors the functionality. Faults can
be indicated on the detector or on a separate line.
•
Connection of remote indicator possible.
Mounting device bracket with insulation
Safety barrier IS conventional 9 V
End of line-resistor 1.8 K / 0.5 W
Sun screen
Plug for the pollution test
•
Single optic test.
Connection / mounting
Connection cable standard detector
2-lead
recommended cable LiYCY 5x0.5 mm2 (0.0008 square inch)
Cable gland
M16x1.5, Brass nickel-plated, EMV
Technical specifications
Detection method
Sensitivity class
Viewing angle
3
60 °
7.6 V - 15 V DC
Quiescent current
approx. 3 mA
Alarm indication
approx. 18 mA
1 LED red
Fault indication current
approx. 7 mA
Fault indication
1 LED yellow
Number of detectors per line
Electrostatic shielding
Operating temperatur
IP rating (EN 60529)
Enclosure material
Relative humidity
(IEC721-3-3)
Weight
P31.312.340 - 2en / 01.14
2 IR Sensoren
Operating voltage
Alarm current
Dimensions
801284
904991
675235
801277
801079
Approvals / marking
Ex conformity in acc. with 94/9/EG:
x II 2G 3G Ex ib IIC T6/T4
Type examination certi¿cate:
DMT 02 ATEX E224
Ex conformity Russia in acc. with TP TC 012/2011:
1Ex ib IIC T6/T4 Gb
G 296016
0786-CPD-20312
max. 4
Required
-25 °C to +80 °C
(-4 °F to +176 °F)
IP 65
Diecast aluminium,
RAL5009-blue
max. 100% at +35 °C (+95 °F)
600 g (1.3 lbs)
127 x 125 x 70 mm (BxHxT)
3.9 x 2 inch (dia. x H)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 6 - 50
Product Sheet | Detecon
Industrial detectors
IR flame detector Ex
FMX3501 Ex SF
Order no.: 903134
Silicone-free Àame detector
FMX3501 Ex 0.2 sec
Order no.: 903135
Flame detectors with fast response within range of miliseconds are used for object monitoring (e.g. tooling machine).
Technical specifications
Criterion of detection
Change of intensity
FMX3501 Ex 0.2 sec SF
Order no.: 903136
Silicone-free Àame detector
FMX3501 Ex T
Order no.: 903137
Flame detector with non-latching alarm
FMX3501 Ex T SF
Order no.: 903138
Silicone-free Àame detector
FMX3501 Ex T 0.2 sec
Order no.: 903139
Flame detectors with fast response within range of miliseconds are used for object monitoring (e.g. tooling machine).
P31.312.340 - 2en / 01.14
Technical specifications
Criterion of detection
FMX3501 Ex T 0.2 sec SF
change of intensity
Order no.: 903140
Silicone-free Àame detector
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 6 - 51
Product Sheet | Detecon
Industrial detectors
IR flame detector Ex
FMX3501 Ex BG
Order no.: 800000
Infrared Àame detector FMX3501 Ex for the detection of open
Àames. Optic test monitors the functionality of the detector.
Designed for use in rough industrial environments. Equipped
for operation as a conventional detector.
Infrared Àame detector FMX3501 Ex are ATEX-approved
for category 2 gas and 3 dust and are suitable for use in Ex
zones 1 and 22.
Intrinsically safe Àame detectors must be connected by correspondingly marked cables to explosion hazard barriers.
Product features
Not included in delivery
•
Highly reliable against false alarms, e.g. from hot surfaces.
•
A microcontroller monitors the functionality. Faults can
be indicated on the detector or on a separate line.
Safety barrier IS conventional 9 V
End of line-resistor 1.8 K / 0.5 W
Sun screen
Plug for the pollution test
•
Connection of remote indicator possible.
•
Single optic test.
Connection / mounting
Connection cable standard detector
2-lead
Recommended cable LiYCY 5x0.5 mm2 (0.0008 square inch)
Cable gland
M16x1.5, brass nickel-plated, EMV
Technical specifications
Detection method
Sensitivity class
Viewing angle
3
60 °
7.6 V - 15 V DC
Quiescent current
approx. 3 mA
Alarm inducation
1 LED red
approx. 7 mA
Fault indication
1 LED yellow
Electrostatic shielding
Operating temperature
IP rating (EN 60529)
Enclosure material
Relative humidity
(IEC721-3-3)
Weight
Dimensions
Approvals / marking
Ex Conformity in acc. with 94/9/EG:
x II 2G 3G Ex ib IIC T6/T4
Type examination certi¿cate:
DMT 02 ATEX E224
Ex conformity Russia in acc. with TP TC 012/2011:
1Ex ib IIC T6/T4 Gb
approx. 18 mA
Fault indication current
Number of detektors per line
P31.312.340 - 3en / 02.14
2 IR Sensoren
Operating voltage
Alarm current
904991
675235
801277
801079
G 296016
0786-CPD-20312
max. 4
Required
-25 °C to +80 °C
(-4 °F to +176 °F)
IP 65
Diecast aluminium,
RAL5009-blue
max. 100% at +35 °C (+95 °F)
750 g (1.6 lbs)
127 x 155 x 92 mm (BxHxT)
5 x 6.1 x 3.6 inch (BxHxT))
FMX3501 Ex BG CN
Order no.: 907436
Version China
Approvals / marking
Otherwise like Order no 800000
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 6 - 52
Product Sheet | Detecon
Industrial detectors
IR flame detector Ex
FMX3501 Ex SF BG
Order no.: 902769
Silicone-free Àame detector
Otherwise like Order no 800000
FMX3501 Ex 0.2 sec BG
Order no.: 902721
Flame detectors with fast response within range of miliseconds are used for object monitoring (e.g. tooling machine).
Otherwise like Order no 800000
Technical specifications
Criterion of detection
Change of intensity
FMX3501 Ex 0.2 sec SF BG
Order no.: 902770
Silicone-free Àame detector
Otherwise like Order no 800000
FMX3501 Ex T BG
Order no.: 903141
Flame detector with non-latching alarm
Otherwise like Order no 800000
FMX3501 Ex T SF BG
Order no.: 903142
Silicone-free Àame detector
Otherwise like Order no 800000
FMX3501 Ex T 0.2 sec BG
Order no.: 903143
Flame detectors with fast response within range of miliseconds are used for object monitoring (e.g. tooling machine).
Otherwise like Order no 800000
P31.312.340 - 3en / 02.14
Technical specifications
Criterion of detection
Change of intensity
FMX3501 Ex T 0.2 sec SF BG
Order no.: 903151
Silicone-free Àame detector
Otherwise like Order no 800000
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 6 - 53
Product Sheet | Detecon
Industrial detectors
UV flame detector Ex
UMX3001 Ex
Order.-no.: 903802
UV Àame detector for the detection of open Àames.
Designed for use in rough industrial environments.
Equipped for operation as a conventional detector.
The UMX3001 Ex Àame detectors are ATEX-approved for
category 2 gas and dust and are suitable for use in Ex zones
1 and 21. The UMX3001 Ex has a pressure resistant casing.
Product fetures
Not included in delivery
•
Wide ¿eld of view.
End of line-resistor 1.8 K / 0.5 W
•
Fast Àame response.
•
High water and dust protection (IP67).
Connection / mounting
Technical specifications
Detections method
Viewing angle
Number of detectors per line
UV-Sensor
110 °
max. 4
Operating voltage
7.6 V - 13.2 V DC
Quiescent cuttent
approx. 1 mA
Alarm current
Alarm indication
Electrostatic shielding
Operating temperature
IP rating (EN 60529)
Enclosure material
Relative humidity
(IEC721-3-3)
Weight
approx. 20 mA
Connection cable standard detector
2-lead
Additional connection latching indication
1-lead
Recommended cable
LIYCY grey 5x0.5 mm2
(0.0008 square inch)
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Conducting cable diameter 5 mm to 9 mm (0.20 to 0.35 inch)
Cable gland metal, EMV, Ex
M16x1.5
Approvals / marking
Ex conformity in acc. with 94/9/EG:
x II 2G Ex d e IIC T6
x II 2D Ex tD A21 IP67 T80°C
1 LED red
requiered
-20 °C to +70 °C
(-4 °F to +158 °F)
IP 67
Diecast aluminium,
silver grey
Type examination certi¿cate:
BVS 04 ATEX E 168 X
max. 95% to +35 °C (95 °F)
3 kg (6.6 lbs)
88 x 190 mm (BxH)
3.5 x 7.5 inch (dia. x H)
P31.312.320 - 2en / 02.13
Dimensions
675235
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 6 - 54
Product Sheet | Detecon
Industrial detectors
Detector accessories
Mounting device console 80x75 Ø54
(3.1x2.9 Ø 2.1 inch)
Order no.: 902898
Mounting device to support gas emission detectors GMX1001CO I.
Included in delivery
1 Mounting device console 80x75 Ø54 complete
2 Countersunk screw DIN923-M5x10 St
5 Self-taping screw DIN7981 C4.2x16
5 Blind rivet 3.2x16 alu
1 O-ring 60x3 Viton
2 Hex screw DIN933-M8x20-A2
2 Spring washer DIN127 B8-1.4310
Technical specifications
Material
Not included in delivery
Plastic POM
Colour
black
Weight
160 g (0.4 lbs)
112 x 112 mm (LxB)
(4.4 x 4.4 inch (LxB)
Adhesive LoctiteAVX 586, 50 ml
886226
Note
Do not install the mounting device console in explosionhazard zone 1
P31.312.810 - 2en / 02.13
Dimensions
902896
835703
885080
885078
132587
772552
820707
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 6 - 55
Product Sheet | Detecon
Industrial detectors
Detector accessories
Mounting device console 125x80 Ø60
(4.9x3.1 Ø 2.3 inch)
Order no.: 801280
Mounting device to support Àame detector FMX3511.
Included in delivery
1 Mounting device console 125x80 Ø60
2 Countersunk screw DIN923-M5x10 St
5 Self-taping screw DIN7981 C4.2x16
5 Blind rivet 3.2x16 alu
1 O-ring 70x3 Viton 70°SH
2 Hex screw DIN933-M8x20-A2
2 Spring washer DIN127 B8-1.4310
Not included in delivery
Technical specifications
Material
801069
835703
885080
885078
800774
772552
820707
Adhesive LoctiteAVX 586, 50 ml
886226
Plastic PETP
Colour
black
Weight
350 g (0.8 lbs)
120 x 150 mm (LxB)
(4.7 x 5.9 inch (LxB)
Dimensions
Mounting device console 125x80 Ø60
(4.9x3.1 Ø 2.3 inch) LSP
Note
Do not install the mounting device console in explosionhazard zone 1.
Order no.: 801281
Mounting device with air Àushing to support and preventive
cleaning of the detector optics of Àame detectors FMX3511.
Included in delivery
1 Mounting device console 125x80 Ø60 LSP
2 Countersunk screw DIN923-M5x10 St
5 Self-taping screw DIN7981 C4.2x16
5 Blind rivet 3.2x16 alu
1 O-ring 60x3 Viton 70°SH
2 Hex screw DIN933-M8x20-A2
2 Spring washer DIN127 B8-1.4310
Not included in delivery
Technical specifications
Medium
Compressed air
P31.312.810 - 2en / 02.13
Pressure range
Connection thread
Material
Adhesive LoctiteAVX 586, 50 ml
886226
Air Àushing has to be supplied with compressed air on site.
0.8 - 1.5 bar
G1/8“, DIN ISO228
Plastic PEPT
Colour
black
Weight
370 g (0.8 lbs)
120 x 150 mm (LxB)
(4.7 x 5.9 inch (LxB)
Dimensions
801298
835703
885080
885078
800774
772552
820707
Note
Do not install the mounting device console in explosionhazard zone 1.
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 6 - 56
Product Sheet | Detecon
Industrial detectors
Detector accessories
Mounting device bracket with insulation
Order no.: 801284
Mounting device to support gas emission detectors, Àame
detectors, spark detectors and spark test light detectors.
Included in delivery
1 Mounting device complete with 2 oval-head screw M8x12
for ¿xing the detector on the bracket.
Not included in delivery
Clamping screw for wall/ceiling mounting.
Technical specifications
Material bracket
Material clamp
Insulating
Weight
Oval-head screw M8x12-1.4301
Hex. nut DIN934-M8-A2/A4
Spring washer DIN127 B8-1.4310
160 g (0.4 lbs)
81.5 x 86 x 31 mm (LxBxH)
(3.2 x 3.4 x1.2 inch (LxBxH)
P31.312.810 - 2en / 02.13
Dimensions
Spare parts
Stainless steel, 2 mm
(0.08 inch) thick
Stainless steel, 1.5 mm
(0.06 inch) thick
Plastic POM
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 6 - 57
800596
820781
820707
Product Sheet | Detecon
Industrial detectors
Detector accessories
Support disk mounting 90 °C (194 °F)
Order no.: 891848
Quick installation device to support detections with
single-hole.
The installation is allowed up to a wall thickness of 8 mm
(0.3 inch).
Technical specifications
Enclosure material:
-mounting coupling
-hex. nut
-oval washer
-tapered block
Operating temperature
stainless steel
brass
stainless steel
Polyamid PA12, black
to +90 °C (+194 °F)
Weight
Support disk mounting 250 °C (482 °F)
120 g (0.3 lbs)
Order no.: 800034
Quick installation device to support detections with
single-hole and ¿bre options.
Technical specifications
Enclosure material:
-tapered block 250 °C
(482 °F)
Operating temperature
Peck / Mod, black
to +250 °C (+482 °F)
Otherwise like Order no. 891848.
Flushing air device
Order no.: 907822
Quick installation device to support detections with
single-hole and air Àushing.
.
Technical specifications
Enclosure material:
V2A and PA 12
-10 °C to +60 °C
(-14 °F to +140 °F)
0.2 to 10 bar
Operating temperature
Operating pressure
Weight
200 g (0.4 lbs)
55 x 48 mm (DxL)
2.2 x 1.9 inch (DxL)
Dimensions
Mounting tool mounting socket - F180
Order no.: 843474
Technical specifications
P31.312.810 - 2en / 02.13
Enclosure material
stainless spring band steel
Weight
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
90 g (0.2 lbs)
Chapter 6 - 58
Product Sheet | Detecon
Industrial detectors
Flame detector accessories
Sun screen FMX3511/FMX3501 Ex
Order no.: 801277
Protection against skewness parasitic radiation (e.g. sunlight
for outside applications) for the Àame detector FMX3511 and
FMX3501 Ex.
Connection / mounting
Plug sun screen onto detector optic.
Note
After mounting the sunscreen can not be removed.
Technical specifications
Colour
Stainless steel, 2.5 mm (0.09 inch)
thick
62.5 x 53 mm (WxH)
2.5 x 2.1 inch (WxH)
internally black
Weight
90 g (0.2 lbs)
Material
Dimensions
Cleaning kit optic
Order no.: 916644
To clean the optic and reÀective surface by Àame detectors.
Included in delivery
P31.312.391en / 02.14
1 packaging unit
(20 cleaning cloth and 10 cleaning sponge)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 6 - 59
Product Sheet | Detecon
Industrial detectors
Gas emission detector
GMX1001CO I
Order no.: 900960
Multi sensor ¿re gas detector GMX1001CO I for the early
detection of smoldering ¿res.
Designed for use in rough industrial environments (e.g. silos,
chip bunkers).
The GMX1001CO I detects the burning characteristic substance carbon monoxide and temperature. False alarms are
nearly impossible.
Equipped for operation as a conventional detector.
Product features
Not included in delivery
•
A microcontroller monitors the functionality and values.
•
Multi sensor carbon monoxide and temperature.
•
Connection of remote indicator possible.
Mounting device bracket with insulation
Mounting device console 80x75 Ø54
End of line-resistor 1.8 K / 0,5 W
Test device smoke generator RG2000
Parallel indicator LMX5000
Technical specifications
Detection method
Alarm threshold:
- Carbon monoxide
- Temperature
- Rate of rise measurement
CO (carbon monoxide)
and temperature
Operating voltage
• 40 ppm
> 60 °C (140 °F)
dT > 3 °C/min. at T
> 36 °C (96,8 °F)
7,6 V - 40 V DC
Quiescent current
approx. 0.15 mA
Alarm current
Alarm indication
Electrostatic shielding
Operating temperature
IP rating (EN 60529)
Enclosure material
Relative humidity
(IEC721-3-3)
Weight
Connection / mounting
Connection cable standard detector
2-lead
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Fire detection cable with static shield
606061
LIYCY grey 5x0.5 mm2 (0.0008 square inch)
Cable gland
M16x1.5, Brass nickel-plated, EMV
Spare parts
Screwed mounting GMX1001COI complete
Sensor GMX1002CO
1 LED red
Required
-20 °C to +50 °C
(-4 °F to +122 °F)
IP 65
Diecast aluminium,
RAL5009-blue
max. 15 to +90 %
no condensation
480 g (1.1 lbs)
122 x 80 x 69 mm (BxHxT)
4.8 x 3.2 x 2.7 inch (BxHxT)
Note
Simple one man calibration.
Approvals / marking
G 204121
0786-CPD-20135
P31.312.610 - 1en / 02.13
Dimensions
approx. 18 mA
801284
902898
675235
902671
908499
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 6 - 60
902923
900968
Product Sheet | Detecon
Industrial detectors
Gas emission detector
GMX1001CO 300ppm
Order no.: 909139
Special detector for application in areas with emissions of
carbon monoxide increased due to operating conditions.
Approvals / marking
Technical specifications
• 300 ppm
> 100 °C (212 °F)
dT > 3 °C/min. at T
> 80 °C (176 °F)
P31.312.610 - 1en / 02.13
Response monoxide:
- Carbon monoxide
- Temperature
- Differential measurement
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 6 - 61
Product Sheet | Detecon
Industrial detectors
Gas emission detector
GMX1001CO I BG
Order no.: 902891
Multi sensor ¿re gas detector GMX1001CO I BG for the early
detection of smoldering ¿res.
Designed for use in rough industrial environments (e.g. silos,
chip bunkers).
The GMX1001CO I detects the burning characteristic substance carbon monoxide and temperature. False alarms are
nearly impossible.
Designed for operation as a conventional detector.
Product features
Not included in delivery
•
A microcontroller monitors the functionality and values.
•
Multi sensor carbon monoxide and temperature.
•
Connection of remote indicator possible.
Mounting device console 80x75 Ø54
End of line-resistor 1.8 K / 0.5 W
Test device smoke generator RG2000
Parallel indicator LMX5000
Connection / mounting
Technical specifications
Detection method
Alarm threshold:
- Carbon monoxide
- Temperature
- Rate of rise measurement
CO (carbon monoxide)
and temperature
Operating voltage
• 40 ppm
> 60 °C (140 °F)
dT > 3 °C/min. at T
> 36 °C (96,8 °F)
7.6 V - 40 V DC
Quiescent current
approx. 0.15 mA
Alarm current
Alarm indication
Electrostatic shielding
Operating temperature
IP rating (EN 60529)
Enclosure material
Relative humidity
(IEC721-3-3)
Weight
Connection cable standard detector
2-lead
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Fire detection cable with static shield
606061
LIYCY grey, 5x0.5 mm2 (0.0008 square inch)
Cable gland
M16x1.5, Brass nickel-plated, EMV
Spare parts
Screwed mounting GMX1001COI complete
Sensor GMX1002CO
approx. 18 mA
1 LED red
Required
-20 °C to +50 °C
(-4 °F to +122 °F)
IP 65
Diecast aluminium,
RAL5009-blue
max. 15 to +90 %
no condensation
600 g (1.3 lbs)
122 x 106 x 88 mm (BxHxT)
4.8 x 4.2 x 3.5 inch (BxHxT)
Note
Simple one man calibration.
Approvals / marking
G 204121
0786-CPD-20135
P31.312.610 - 2en / 02.13
Dimensions
902898
675235
902671
908499
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 6 - 62
902923
900968
Product Sheet | Detecon
Industrial detectors
Gas emission detector
GMX1001CO 300ppm BG
Order no.: 909161
Special detector for application in areas with emissions of
carbon monoxide increased due to operating conditions.
Approvals / marking
Technical specifications
• 300 ppm
> 100 °C (212 °F)
dT > 3 °C/min. at T
> 80 °C (176 °F)
P31.312.610 - 2en / 02.13
Response values:
- Carbon monoxide
- Temperature
- Differential measurement
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 6 - 63
Product Sheet | Detecon
Industrial detectors
Gas emission detector
GMX1001CO I Console
Order no.: 902893
Multi sensor ¿re gas detector GMX1001CO I Console for the
early detection of smoldering ¿res.
Designed for use in rough industrial environments (e.g. silos,
chip bunkers). Version bracket mount.
The GMX1001CO I detects the burning characteristic substance carbon monoxide and temperature. False alarms are
nearly impossible.
Designed for operation as a conventional detector.
Product features
Not included in delivery
•
A microcontroller monitors the functionality and values.
•
Multi sensor carbon monoxide and temperature.
•
Connection of remote indicator possible.
Mounting device bracket with insulation
End of line-resistor 1.8 K / 0.5 W
Test device smoke detector RG2000
Parallel indicator LMX5000
Connection / mounting
Technical specifications
Detection method
Alarm threshold:
- Carbon monoxid
- Temperature
- Rate of rise measurement
CO (carbon monoxide)
and temperature
Operating voltage
• 40 ppm
> 60 °C (140 °F)
dT > 3 °C/min. at T
> 36 °C (96.8 °F)
7.6 V - 40 V DC
Quiescent current
approx. 0.15 mA
Alarm current
Alarm indication
Electrostatic shielding
Operating temperature
IP rating (EN 60529)
Enclosure material
Relative humidity
(IEC721-3-3)
Weight
approx. 18 mA
1 LED red
Required
-20 °C to +50 °C
(-4 °F to +122 °F)
IP 65
Diecast aluminium,
RAL5009-blue
max. 15 at +90 %
no condensation
600 g (1.3 lbs)
122 x 112 x 75 mm (BxHxT)
4.8 x 4.4 x 3 inch (BxHxT)
Connection cable standard detector
2-lead
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Fire detection cable with static shield
606061
LIYCY grey, 5x0.5 mm2 (0.0008 square inch)
Cable gland
M16x1.5, Brass nickel-plated, EMV
Spare parts
Screwed mounting GMX1001COI complete
Sensor GMX1002CO
Note
Simple one man calibration.
Approvals / marking
P31.312.610 - 3en / 02.13
Dimensions
801284
675235
902671
908499
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 6 - 64
902923
900968
Product Sheet | Detecon
Industrial detectors
Gas emission detector
GMX1001CO 300ppm Console
Order no.: 909162
Special detector for application in areas with emissons of
carbon monoxide increased due to operating conditions.
Approvals / marking
Technical specifications
• 300 ppm
> 100 °C (212 °F)
dT > 3 °C/min. at T
> 80 °C (96.8 °F)
P31.312.610 - 3en / 02.13
Response values:
- Carbon monoxide
- Temperature
- Differential measurement
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 6 - 65
Product Sheet | Detecon
Industrial detectors
Gas emission detector Ex
GMX1001CO Ex Dust
Order no.: 905642
Multi sensor ¿re gas detector GMX1001CO Ex Dust for the
early detection of smoldering ¿res.
Designed for use in raugh industrial environments (e.g. silos,
chip bunkers).
The GMX1001CO I detects the burning characteristic substance carbon monoxide and temperature. False alarms are
nearly impossible.
Designed for operation as a conventional detector.
The GMX1001CO Ex Dust gas detectors are ATEX-approved
for category 1 and 2 dust and are suitable for use in Ex zone
20 and 21.
Product features
Not included in delivery
•
A microcontroller monitors the functionality and values.
•
Multi sensor carbon monoxide and temperature.
•
Connection of remote indicator possible.
Mounting device bracket with insulation
Mounting device console 80x75Ø54
End of line-resistor 1.8 K / 0.5 W
Test device smoke generator RG2000
Parallel indicator LMX5000
Technical specifications
Detection method
Alarm threshold:
- Carbon monoxide
- Temperature
- Rate of rise measurement
Number of detectors per line
CO (carbon monoxide)
and temperature
• 40 ppm
> 60 °C (140 °F)
dT > 3 °C/min. at T
> 36 °C (96.8 °F)
max. 32
Operating voltage
7.6 V - 40 V DC
Quiescent current
approx. 0.15 mA
Alarm current
Alarm indication
Electrostatic shielding
Operating temperature
IP rating (EN 60529)
Enclosure material
Relative humidity
(IEC721-3-3)
Weight
1 LED red
Required
-20 °C to +50 °C
(-4 °F to +122 °F)
IP 65
Diecast aluminium,
RAL5009-blue
max. 15 at + 90 %
no condensation
480 g (1.1 lbs)
122 x 80 x 69 mm (BxHxT)
4.8 x 3.2 x 2.7 inch (BxHxT)
Connection / mounting
Connection cable standard detector
2-lead
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Fire detection cable with static shield
606061
LIYCY grey, 5x0.5 mm2 (0.0008 square inch)
Cable gland
M16x1.5, Brass nickel-plated, EMV, Ex
Spare parts
Screwed GMX1001COI complete
Sensor GMX1002CO
902923
900968
Hinweis
Simple one man calibration
Approvals
Ex conformity in acc. with 94/9/EG:
x II 1/2D Ex tD A20/21 IP65 T136°C
x II 1D Ex tD A20 IP65 T136°C
Type examination certi¿cate:
BVS 05 ATEX E179
Approvals / marking
G 204121
0786-CPD-20135
P31.312.620 - 1en / 02.13
Dimensions
appro. 18 mA
801284
902898
675235
902671
908499
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 6 - 66
Product Sheet | Detecon
Industrial detectors
Gas emission detector Ex
GMX1001CO Ex Dust BG
Order no.: 905643
Multi sensor ¿re gas detector GMX1001CO Ex Dust BG for
the early detection of smoldering ¿res.
Designed for use in raugh industrial environments (e.g. silos,
chip bunkers).
The GMX1001CO I detects the burning characteristic substance carbon monoxide and temperature. False alarms are
nearly impossible.
Designed for operation as a conventional detector.
The GMX1001CO Ex Dust BG gas detectors are ATEXapproved
for category 1 and 2 dust and are suitable for use in Ex zone
20 and 21.
Product features
Not included in delivery
•
A microcontroller monitors the functionality and values.
•
Multi sensor carbon monoxide and temperature.
•
Connection of remote indicator possible.
Mounting device console 80x75Ø54
End of line-resistor 1.8 K / 0.5 W
Test device smoke generator RG2000
Parallel indicator LMX5000
Connection / mounting
Technical specifications
Detection method
Alarm threshold:
- Carbon monoxide
- Temperature
- Rate of rise measurement
CO (carbon monoxide)
and temperature
Operating voltage
• 40 ppm
> 60 °C (140 °F)
dT > 3 °C/min. at T
> 36 °C (96.8 °F)
7.6 V - 40 V DC
Quiescent current
approx. 0.15 mA
Alarm current
Alarm indication
Electrostatic shielding
Operating temperature
IP rating (EN 60529)
Enclosure material
Relative humidity
(IEC721-3-3)
Weight
approx. 18 mA
1 LED red
Required
-20 °C to +50 °C
(-4 °F to +122 °F)
IP 65
Diecast aluminium,
RAL5009-blue
max. 15 to + 90 %
no condensation
600 g (1.3 lbs)
122 x 106 x 88 mm (BxHxT)
4.8 x 4.2 x 3.5 inch (BxHxT)
Connection cable standard detector
2-lead
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Fire detection cable with static shield
606061
LIYCY grey, 5x0.5 mm2 (0.0008 square inch)
Cable gland
M16x1.5, Brass nickel-plated, EMV, Ex
Spare parts
Screwed GMX1001COI complete
Sensor GMX1002CO
902923
900968
Note
Simple one man calibration
Approvals / marking
Ex conformity in acc. with 94/9/EG:
x II 1/2D Ex tD A20/21 IP65 T136°C
x II 1D Ex tD A20 IP65 T136°C
Type examination certi¿cate:
BVS 05 ATEX E179
G 204121
0786-CPD-20135
P31.312.620 - 2en / 02.13
Dimensions
902898
675235
902671
908499
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 6 - 67
Product Sheet | Detecon
Industrial detectors
Gas emission detector Ex
GMX1001CO Ex Dust Console
Order no.: 905644
Multi sensor ¿re gas detector GMX1001CO Ex Dust Console
for the early detection of smoldering ¿res.
Designed for use in rough industrial environments (e.g. silos,
chip bunkers). Version bracket mount.
The GMX1001CO I detects the burning characteristic substance carbon monoxide and temperature. False alarms are
nearly impossible.
Equipped for operation as a conventional detector.
The GMX1001CO Ex Dust Console gas detectors are ATEXapproved
for category 1 and 2 dust and are suitable for use in Ex zone
20 and 21.
Product features
•
A microcontroller monitors the functionality and values.
Not included in delivery
•
Multi sensor carbon monoxide and temperature.
•
Connection of remote indicator possible.
Mounting device bracket with insulation
End of line-resistor 1.8 K / 0.5 W
Test device smoke generator RG2000
Parallel indicator LMX5000
Technical specifications
Detection method
Alarm threshold:
- Carbon monoxide
- Temperature
- Rate of rise measurement
CO (carbon monoxide)
and temperature
Operating voltage
• 40 ppm
> 60 °C (140 °F)
dT > 3 °C/min. at T
> 36 °C (96.8 °F)
7.6 V - 40 V DC
Quiescent current
approx. 0.15 mA
Alarm current
Alarm indication
Electrostatic shielding
Operating temperature
IP rating (EN 60529)
Enclosure material
Relative humidity
(IEC721-3-3)
Weight
1 LED red
Required
-20 °C to +50 °C
(-4 °F to +122 °F)
IP 65
Diecast aluminium,
RAL5009-blau
max. 15 to + 90 %
no condensation
600 g (1.3 lbs)
122 x 112 x 75 mm (BxHxT)
4.8 x 4.4 x 3 inch (BxHxT)
Connection / mounting
Connection cable standard detector
2-lead
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Fire detection cable with static shield
606061
LIYCY grey, 5x0.5 mm2 (0.0008 square inch)
Cable gland
M16x1.5, Brass nickel-plated, EMV, Ex
Spare parts
Screwed GMX1001COI complete
Sensor GMX1002CO
902923
900968
Note
Simple one man calibration
Approvals / marking
Ex conformity in acc. with 94/9/EG:
x II 1/2D Ex tD A20/21 IP65 T136°C
x II 1D Ex tD A20 IP65 T136°C
Type examination certi¿cate:
BVS 05 ATEX E179
0786-CPD-20135
P31.312.620 - 3en / 02.13
Dimensions
approx. 18 mA
801284
675235
902671
908499
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 6 - 68
Product Sheet | Detecon
Aspirating smoke detectors
AMX4004, basic devices
AMX4004
Order no.: 909244
The aspirating smoke detector AMX4004 is an active smoke
detection system that can be individually tuned to the application area with up to three different detector heads. Up to 12
suction holes with a 100 m (328 ft) pipe system are possible
thanks to the powerful fan.
Application
Product features
•
Up to three combined sensors can be used for different
application areas (scattered light smoke sensor, ionisation smoke sensor, Àue gas sensor).
Included in delivery
•
High aspiration capacity.
1 aspirating smoke detector AMX4004
•
Scattered light smoke sensors for different sensitivity
ranges, with pollution compensation for use in critical
environments.
Not included in delivery
•
Ionisation smoke sensor for detecting very small and
dark smoke particles.
•
Flue gas sensor for earliest ¿re detection (40 ppm CO).
•
Integrated LC display for indicating status information.
•
Con¿gurable without accessories (menu-controlled).
Operating voltage
Rated voltage
Measuring principle
Max. current consumption
Max. contact load
IP rating
Detector heads:
Optical smoke detector OMX1002C 1HE,
2.73 % / m (0.83 % / ft)
Optical smoke detector OMX1002C HS 1HE,
0.34 % / m (0.10 % / ft)
Optischer Rauchmelder OMX1002C VHS 1HE,
0.11 % / m (0.04 % / ft)
Ionisation smoke detector IMX1002E 1HE, y=0.8
Flue gas detector GMX1002CO 1HE, 40 ppm
909244
906323
906324
910389
909491
909492
Notes
Technische Daten
P31.313.110en / 02.13
Aspirating smoke detector for the detection of smoke particles and/or Àue gases in aspirated air samples. The system
actively draws air samples from the monitored area via a pipe
system. Typical application areas are:
- Equipment monitoring: computer rooms, warehouses,
high rack storage areas, hollow Àoors.
- cultural assets protection, transformer stations, etc.
18 V - 30 V DC
24 V DC
The AMX4004 uses three limit lines (current increase lines)
for three alarms as well as one fault line for connection to the
¿re detection system FMZ 5000. In addition, Àoating contacts
for three alarms as well as fault are available.
dependent on detector heads
Detector ca. 400 mA
Approvals / marking
60 V DC, 1 A
IP 54
-20 °C to +50 °C
Ambient temperature
(-4 °F to +122 °F)
Sampling pipe
25 mm (0.98 inch)
max. overall length 100 m (328 ft)
Sampling pipe length
max. 50 m (164 ft) as single strand
max. 95 %,
Relative humidity
at 35 °C (+95 °F), no condensation
Enclosure material
Die cast aluminium
4 x M16, clamping range 5-9 mm
Cable gland
(0.19 - 0.35 inch)
Weight without detector head
2.8 kg (6.2 lbs)
Dimensions without
280 x 170 x 90 mm (WxHxD)
cable gland
11.02 x 6.7 x 3.5 inch (WxHxD)
G 212001
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
0786-CPD-21095
Chapter 7 - 1
Product Sheet | Detecon
Aspirating smoke detectors
AMX4004, basic devices
AMX4004 WEA
Order no.: 909043
Basic device especially for use in wind energy converters
(with integrated controlled heating).
Technical specifications
Heating approx. 1.4 A
P31.313.110en / 02.13
Max. current
consumption
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 7 - 2
Product Sheet | Detecon
Aspirating smoke detectors
AMX4004, detector heads
Optical smoke detector OMX1002C 1HE
Order no.: 906323
Technical specifications
Sensitivity
2.73 % / m (0.83 % / ft)
Weight
0.07 kg (0.15 lbs)
55 x 40 mm (DxH)
2.16 x 1.57 inch (DxH)
Dimensions
Optical smoke detector OMX1002C HS
1HE
Order no.: 906324
Technical specifications
Sensitivity
0.34 % / m (0.10 % / ft)
Weight
0.07 kg (0.15 lbs)
55 x 40 mm (DxH)
2.16 x 1.57 inch (DxH)
Dimensions
Optical smoke detector OMX1002C VHS
1HE
Order no.: 910389
Technical specifications
Sensitivity
0.11 % / m (0.04 % / ft)
Weight
0.07 kg (0.15 lbs)
55 x 40 mm (DxH)
2.16 x 1.57 inch (DxH)
Dimensions
Ionisation smoke detector IMX1002E 1HE
Order no.: 909491
Technical specifications
Sensitivity
y = 0.8
Weight
0.1 kg (0.02 lbs)
55 x 40 mm (DxH)
2.16 x 1.57 inch (DxH)
Dimensions
Flue gas detector GMX1002 CO 1HE
Order no.: 909492
Technical specifications
Trigger value
Carbon monoxide
Weight
40 ppm
0.05 kg (0.05 lbs)
55 x 40 mm (DxH)
2.16 x 1.57 inch (DxH)
P31.313.120en / 02.13
Dimensions
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 7 - 3
Product Sheet | Detecon
Aspirating smoke detectors
HELIOS AMX5000, basic devices
AMX5001
Order no.: 908095
The HELIOS AMX5000 aspirating smoke detector is a
highly sensitive active smoke detection system of the latest
generation. In addition to monitoring advance signals and
contamination, it also provides the option of the user-speci¿c
adjustment of the sensitivity.
The powerful fan enables up to 24 sampling holes with 200 m
(656 ft) pipe system per smoke sensor.
The HELIOS AMX5000 is even able to detect the smallest
smoldering ¿res and can be used practically everywhere.
Version AMX5001: basic device with simple display.
For 1 sampling pipe and 1 smoke sensor.
Application
Product features
•
•
•
•
•
•
Autolearning function.
Separate airÀow monitoring with one or two aspiration
lines.
Adjustable sensitivity of 0.002 - 10 % / m
(0.0006 - 3.049 % / ft).
High sampling power (high negative pressure of 400 Pa).
Highly sensitive smoke sensors with contamination
compensation for use in critical environments.
Full integration into the Minimax ¿re alarm system
FMZ 5000.
Rated voltage
Number of relays
Max. contact load
50 V DC, 1 A
Advance signals 1,2,3
Max. current consumption
IP rating
Ambient temperature
Intake pressure
Suction noise at fan level 3
(standard)
Number of installation spaces
for add-on modules
Sampling pipe
Relative humidity
P31.313.310en / 02.14
10.5 - 30 V DC
24 V DC
0.02 % / m - 10 % / m
(0.006 % / ft - 3.049 % / ft)
0.002 - 10 % / m
(0.0006 % / ft - 3.049 % / ft,
programmable in increments of 10 %
Inactive/fault approx. 340 mA
Alarm I approx. 390 mA
3
Alarm sensitivity
Enclosure material
Speci¿cation according to
Weight
Dimensions
Included in delivery
1 aspirating smoke detector AMX5001
908095
Not included in delivery
Technical specifications
Operating voltage
Aspirating smoke detector for the detection of smoke
particles by air sampling. The system takes on air sampling
probe in from the monitoring area via a pipe system.
Typical applications:
Equipment monitoring: IT systems, electrical distributors,
switch cabinets, etc.
Room monitoring: IT rooms, clean rooms, warehouses,
high rack storage areas, hollow Àoors, protection of objects
of cultural value, transformer stations, etc.
IP 54
-30 °C to +60 °C
(-22 °F to +140 °F)
> 400 Pa (power level 5)
43 dB (A)
4
Plug-in system 25 mm (0.98 inch)
max. 95 %,
temporarily without condensation
70 %, constantly
ABS-Blend, UL 94-V0
Smoke sensor OMX5005,
0.5 % /m - 10 % / m (0.152 % / ft - 3.049 % / ft)
Smoke sensor OMX5010,
0.1 % / m - 10 % / m (0.030 % / ft - 3.049 % / ft)
Smoke sensor OMX5020,
0.02 % / m - 10 % / m (0.006 % / ft - 3.049 % / ft)
Relay module KMX5005 RK
Memory module MMX5005
Con¿guration software HELIOS Con¿g
Project planning software HELIOS PipeCalc
908099
908100
908101
908103
908104
908105
908106
Spare parts
Case fastener (4 pieces)
909434
Notes
The HELIOS AMX5000 can be connected to a higher-level
¿re alarm panel via dry changeover contacts. The HELIOS
AMX5000 can be integrated into the FMZ5000 ¿re alarm
system with LoopAP via modules. Indication and operation
are thus possible at the ¿re alarm panel.
Approvals / marking
G 208193
0786-CPD-20637
EN 54-20, classes A, B and C
3.85 kg (8.5 lbs)
265 x 397 x 146 mm (WxHxD)
10.4 x 15.6 x 5.8 inch (WxHxD)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 7 - 4
Product Sheet | Detecon
Aspirating smoke detectors
HELIOS AMX5000, basic devices
AMX5002
Order no.: 908096
Basic device with simple display.
For 2 aspiration tubes and 2 smoke sensors.
Technical specifications
Max. current consumption
Inactive/fault approx. 380 mA
Alarm I approx. 450 mA
AMX5101
Order no.: 908097
Basic device with 10-LED display.
For 1 aspiration tube and 1 smoke sensor.
Technical specifications
Max. current consumption
Inactive/fault approx. 340 mA
Alarm I approx. 405 mA
AMX5102
Order no.: 908098
Basic device with 10-LED display.
For 2 aspiration tubes and 2 smoke sensors.
Technical specifications
Inactive/fault approx. 380 mA
Alarm I approx. 490 mA
P31.313.310en / 02.14
Max. current consumption
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 7 - 5
Product Sheet | Detecon
Aspirating smoke detectors
HELIOS AMX5000, detector heads
Smoke sensor OMX5005
Order no.: 908099
Technical specifications
Sensitivity
Weight
Dimensions
Smoke sensor OMX5010
0.5 % / m - 10 % / m
(0.152 % / ft - 3.049 % / ft)
0.30 kg (0.66 lbs)
150 x 125 x 95 mm (WxHxD)
5.90 x 4.92 x 3.74 inch (WxHxD)
Order no.: 908100
Technical specifications
Sensitivity
Weight
Dimensions
Smoke sensor OMX5020
0.1 % / m - 10 % / m
(0.030 % / ft - 3.049 % / ft)
0.30 kg (0.66 lbs)
150 x 125 x 95 mm (WxHxD)
5.90 x 4.92 x 3.74 inch (WxHxD)
Order no.: 908101
Technical specifications
Sensitivity
Weight
P31.313.320en / 02.14
Dimensions
0.02 % / m - 10 % / m
(0.006 % / ft - 3.049 % / ft)
0.30 kg (0.66 lbs)
150 x 125 x 95 mm (WxHxD)
5.90 x 4.92 x 3.74 inch (WxHxD)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 7 - 6
Product Sheet | Detecon
Aspirating smoke detectors
HELIOS AMX5000, detector heads
Detector interface AMX1002 IF
Order no.: 908102
Detector can be used to insert up to two detector heads.
Detection of pre-alarm and main alarm via the HELIOS
AMX5000.
Technical specifications
Weight
Dimensions
Optical smoke detector OMX1002 C
0.26 kg (0.56 lbs)
150 x 115 x 95 mm (WxHxD)
5.90 x 4.52 x 3.74 inch (WxHxD)
Order no.: 801226
Detector head for use in the HELIOS AMX5000 via the
detector interface AMX1002 IF.
Technical specifications
Sensitivity
2.73 % / m (0.83 % / ft)
Weight
0.07 kg (0.56 lbs)
55 x 55 mm (DxH)
2.16 x 2.16 inch (DxH)
Dimensions
Optical smoke detector OMX1002C HS
Order no.: 904639
Detector head with increased sensitivity for use in the
HELIOS AMX5000 via the detector interface AMX1002 IF.
Technical specifications
Sensitivity
0.34 % / m (0.10 % / ft)
Weight
0.07 kg (0.56 lbs)
55 x 55 mm (DxH)
2.16 x 2.16 inch (DxH)
Dimensions
Ionisation smoke detector IMX1002E
Order no.: 797144
Technical specifications
Sensitivity
y = 0,8
Weight
0.06 kg (0.13 lbs)
55 x 55 mm (DxH)
2.16 x 2.16 inch (DxH)
Dimensions
P31.313.320en / 02.14
Flue gas detector GMX1002 CO
Order no.: 900959
Technical specifications
Trigger value
Carbon monoxide
Weight
40 ppm
0.06 kg (0.13 lbs)
55 x 35 mm (DxH)
2.16 x 1.37 inch (DxH)
Dimensions
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 7 - 7
Product Sheet | Detecon
Aspirating smoke detectors
Vesda laser, basic devices
LaserFocus VLF-250
Order no.: 908495
The LaserFocus VLF-250 is designed to ensure extremely
early smoke detection for small and operationally critical
areas. The detector constantly takes air samples through
inlets to a pipe network where the air is ¿ltered and sent
to a collection chamber. Using light dispersion technology,
the presence of even the smallest amounts of smoke
can be identi¿ed. An immediate airÀow rate measuring
value display on the air inlet pipe presents the ultrasound
airÀow rate reading. The system is resistant to changes in
air temperature and air pressure and is not damaged by
impurities.
Product features
Included in delivery
•
Two-leval air ¿ltering.
1 LaserFocus VLF-250
•
•
AutoLearn alarm thresholds and air Àow rate.
Ultrasonic airÀow rate reading.
Not included in delivery
•
Laser-based, absolute smoke identi¿cation.
•
Programmable alarm threshold values.
•
Pre-set pipe network constructions.
•
Installation and start-up can be carried out in delivered
condition.
Mounting hardware
Approvals / marking
G 205060
0832-CPD-0771
Technical specifications
Sensitivity range
Ambient temperature
Temperature of the aspirated
air
Operating voltage
Rated voltage
24 V DC
Quiescent current
220 mA
Alarm current
295 mA
Rated output
5.2 W
Rated output for alarm
7.0 W
Areas of coverage
IP rating
Maximum pipe length
Event memory
Aspiration tube
Relative humidity
P31.313.410en / 02.13
0.025 - 20 %/m (39 inch)
0 °C to +40 °C
(32 °F to +104 °F)
0 °C to +40 °C
(32 °F to +104 °F)
18 - 30 V DC
Colour of enclosure
Weight
Dimensions
max. 250 m2 (2691 square foot)
IP 30
1 x 25 m (984 inch),
2 x 15 m (590 inch)
max. 18000 entries
Plug-in system 25 mm (0.98 inch)
5 - 95 %,
No condensation
Light grey
2.0 kg (4.4 lbs)
255 x 185 x 90 mm (WxHxD)
8.9 x7.3 x 3.5 inch (WxHxD)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 7 - 8
Product Sheet | Detecon
Aspirating smoke detectors
Vesda laser, basic devices
LaserCompact VLC-400 AP
Order no.: 908494
The LaserCompact detector VLC-400 AP is designed for
use with FMZ 5000 ¿re detection control panel with Loop
AP communication protocol. The VLC-400 AP is equipped
with an integrated loop isolator on the main processor card.
The detector units all the advantages of aspiration smoke
detection, including early warning in small areas. Via a simple
pipe network, a high-performance aspirator continuously
sucks air into a central detector. On the ¿rst level, dust
and dirt are ¿ltered before the air reaches the early smoke
detector in the detector chamber. In order to guarantee
optimal response to a large variety of smoke types, a highly
effective laser light source and a sensor con¿guration are
used in the detector chamber.
Included in delivery
Product features
•
•
•
•
•
1 LaserCompact VLC-400 AP
Large sensitivity range.
AutoLearn.
AirÀow monitoring.
Absolute smoke detection.
Compatible with Loop AP technology.
Not included in delivery
Mounting hardware
Approvals / marking
Technical specifications
Sensitivity range
Temperature of the aspirated
air
Communication protocol
0.005 - 20 %/m (39 inch)
-10 °C to +39 °C
(+14 °F to +102.2 °F)
-20 °C to +60 °C
(-4 °F to +140 °F)
Loop AP
Number of detectors per loop
Max. 126
Ambient temperature
Isolators
0832-CPD-0770
1 loop isolator
Operating voltage
Rated voltage
18 - 30 V DC
24 V DC
Quiescent current
225 mA
Alarm current
245 mA
Rated output
5.4 W
Rated output for alarm
Areas of coverage
IP rating
Maximum pipe length
Event memory
Aspiration tube
Relative humidity
P31.313.410en / 02.13
G 203025
Colour of enclosure
Weight
Dimensions
5.9 W
max. 800 m2 (8611 square feet)
IP 30
1 x 80 m (3150 inch),
2 x 50 m (1968 inch)
max. 10240 entries
Plug-in system 25 mm (0.98 inch)
10 - 95 %,
No condensation
Light grey
1900 g (4.2 lbs)
225 x 225 x 85 mm (WxHxD)
8.9 x 8.9 x 3.9 inch (WxHxD)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 7 - 9
Product Sheet | Detecon
Aspirating smoke detectors
Vesda laser, basic devices
LaserCompact VLC-500
Order no.: 908492
The LaserCompact detector VLC-500 unites all the
advantages of aspirating smoke detection, including early
warning in small areas where space is of upmost importance.
Via a simple pipe network, a high-performance aspirator
continuously sucks air into a central detector. On the ¿rst
level, dust and dirt are ¿ltered before the air reaches the
early smoke detector in the detector chamber. In order to
guarantee optimal response to a large variety of smoke
types, a highly effective laser light source and a sensor
con¿guration are used in the detector chamber. The status of
all detectors, alarms, maintenance and fault noti¿cations are
monitored and saved with time and date stamps.
Included in delivery
Product features
•
•
•
•
•
•
•
•
•
Large sensitivity range.
Two-level dust ¿lter.
AutoLearn.
AirÀow monitoring.
Absolute smoke detection.
Three alarm settings (information, pre-alarm and main
alarm).
Three programmable relays.
Single pipe inlet.
Simple built-in construction.
1 LaserCompact VLC-500
Not included in delivery
Mounting hardware
Approvals / marking
G 298024
0832-CPD-0770
Technical specifications
Sensitivity range
Ambient temperature
Temperature of the aspirated
air
Operating voltage
0.005 - 20 %/m (39 inch)
-10 °C to +39 °C
(+14 °F to +102.2 °F)
-20 °C to +60 °C
(-4 °F to +140 °F)
18 - 30 V DC
Rated voltage
24 V DC
Quiescent current
225 mA
Alarm current
245 mA
Rated output
5.4 W
Rated output for alarm
Areas of coverage
IP rating
Maximum pipe length
Event memory
P31.313.410en / 02.13
Aspiration tube
Relative humidity
Colour of enclosure
Weight
Dimensions
5.9 W
max. 800 m (8611 square feet)
2
IP 30
1 x 80 m (3150 inch),
2 x 50 m (1968 inch)
max. 12000 entries
Plug-in system 25 mm (0.98 inch)
10 - 95 %,
No condensation
Light grey
1900 g (4.2 lbs)
225 x 225 x 85 mm (WxHxD)
8.9 x 8.9 x 3.4 inch (WxHxD)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 7 - 10
Product Sheet | Detecon
Aspirating smoke detectors
Sampling pipes
Pipe 25 x 1.5 mm (98 x 0.06 inch)
Order no.: 905253
Technical specifications
Material
Sleeve 25 mm (98 inch)
PVC pressure pipe, grey, 10 bar
Weight
1.0 kg (2.2 lbs)
Length
5000 mm (196.9 inch)
Order no.: 905264
Technical specifications
Adhesive cap 25 mm (98 inch)
Material
PVC, grey, 16 bar
Weight
0.01 kg (0.02 lbs)
Order no.: 905263
Technical specifications
Elbow 90° 25 x 13.5 mm (98 x 0.53 inch)
Material
PVC, grey, 16 bar
Weight
0.01 kg (0.02 lbs)
Order no.: 905255
Technical specifications
Bend 90° 25 x 37.5 mm (98 x 1.37 inch)
Material
PVC, grey, 16 bar
Weight
0.03 kg (0.07 lbs)
Order no.: 905254
Technical specifications
Material
PVC, grey, 16 bar
Weight
Elbow 45° 25 x 6 mm (98 x 0.23 inch)
0.05 kg (0.1 lbs)
Order no.: 905256
P31.313.810en / 02.13
Technical specifications
Material
PVC, grey, 16 bar
Weight
0.03 kg (0.07 lbs)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 7 - 11
Product Sheet | Detecon
Aspirating smoke detectors
Sampling pipes
T-piece 90° 3 x 25 mm (0.11 x 98 inch)
Order no.: 905262
Technical specifications
Coupling 25 mm (98 inch)
Material
PVC, grey, 16 bar
Weight
0.03 kg (0.07 lbs)
Order no.: 905265
Technical specifications
Material
PVC, grey, 16 bar
Weight
Seal 1.1/4“ (spare seal for coupling)
0.06 kg (0.1 lbs)
Order no.: 905283
Technical specifications
Material
NBR
Weight
Hose piece for active detector
0.04 kg (0.1 lbs)
Order no.: 904393
Technical specifications
Material
Hose flexible D21 grey
PVC hose with steel reel
Weight
0.15 kg (0.33 lbs)
Length
350 mm (0.3 inch)
Order no.: 834784
Technical specifications
Material
P31.313.810en / 02.13
Ceiling duct set, PVC, d=21.2
PVC hose Àexible
Weight
2.5 kg (5.5 lbs)
Lenght
cable roll to 10 m (394 inch)
Order no.: 908699
Complete suction set for installation in the PVC sensor pipe
system d=25 mm (0.98 inch), e.g. for suspended ceilings, for
taking air samples from a room. Length: 0.8 m (31.5 inch).
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 7 - 12
Product Sheet | Detecon
Aspirating smoke detectors
Aspirating pipes - connections/accessories
Pipe clamp 25 - 28 mm (0.98 - 1.10 inch)
Order no.: 905266
Technical specifications
Material
PP black
P31.313.840en / 02.13
Weight
Sampling hole clip d=2.0 mm (0.08 inch)
red
Order no.: 908331
Sampling hole clip d=2.5 mm (0.09 inch)
red
Order no.: 908332
Sampling hole clip d=3.0 mm (0.11 inch)
red
Order no.: 908333
Sampling hole clip d=3.5 mm (0.14 inch)
red
Order no.: 908334
Sampling hole clip d=4.0 mm (0.16 inch)
red
Order no.: 908335
Sampling hole clip d=4.5 mm (0.18 inch)
red
Order no.: 908336
Sampling hole clip d=5.0 mm (0.19 inch)
red
Order no.: 908337
Sampling hole clip d=5.5 mm (0.22 inch)
red
Order no.: 908338
Sampling hole clip d=6.0 mm (0.24 inch)
red
Order no.: 908339
Sampling hole clip d=6.5 mm (0.26 inch)
red
Order no.: 908340
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
0.01 kg (0.02 lbs)
Chapter 7 - 13
Product Sheet | Detecon
Aspirating smoke detectors
Aspirating pipes - connections/accessories
Order no.: 908341
Sampling hole revision red
Order no.: 908342
P31.313.840en / 02.13
Sampling hole clip d=7.0 mm (0.28 inch)
red
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 7 - 14
Product Sheet | Detecon
Aspirating smoke detectors
Aspiration tube system, mounting accessories
Adhesive: TANGIT PVC glue
Order no.: 905267
Technical specifications
Container
500 g (1.1 lbs) can with brush
Weight
TANGIT PVC cleaner
0.8 kg (1.76 lbs)
Order no.: 905269
Technical specifications
Container
Funnel bottle 1000 ml (0.26 Gallone)
1.1 kg (2.42 lbs)
P31.313.850 / 02.13
Weight
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 7 - 15
Product Sheet | Detecon
Aspirating smoke detectors
Fittings
Pipe cutter plastic pipe + hose
Order no.: 905281
For plastic pipes and hoses of 6 - 35 mm (0,23 to 1.38 inch).
Three-way ball valve, d=25 mm (0.98 inch)
Order no.: 908548
For connecting compressed air to blow the sensor pipework
clean.
Pipe blow-valve, PVC, automatic
Order no.: 908721
Included in delivery
1 PVC sleeve d=40 mm (1.57 inch)
1 PVC reducer d=40/25 mm (1.57/0.98 inch)
1 backÀow preventer
Compressed-air connection for PVC-DWK
d=25 mm (0.98 inch)
Order no.: 908722
Included in delivery
1 PVC adapter sleeve
1 brass reducing adapter
1 compressed-air coupling
Sampling fitting set with heater, PVC, red
Order no.: 908723
For creating the pipe system at temperatures down to - 30°C
(-22 °F).
Included in delivery
1 PVC T-piece including heating resistor and
suction port d=5.7 mm (0.22 inch), colour coding: red
Sampling fitting set with heater, PVC,
yellow
Order no.: 908724
For creating the pipe system at temperatures down to - 30°C
(-11 °F).
Included in delivery
1 PVC T-piece including heating resistor and
suction port d=5.9 mm (0.23 inch), colour coding: yellow
P31.313.820en / 02.13
Sampling fitting set with heater, PVC, blue
Order no.: 908725
For creating the pipe system at temperatures down to - 30°C
(-22 °F).
Included in delivery
1 PVC T-piece including heating resistor and
suction port d=6.1 mm (0.24 inch), colour coding: blue
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 7 - 16
Product Sheet | Detecon
Aspirating smoke detectors
Fittings
Sampling fitting set with heater, PVC,
green
Order no.: 908726
For creating the pipe system at temperatures down to - 30°C
(-22 °F).
Included in delivery
1 PVC T-piece including heating resistor and
suction port d=6.3 mm (0.25 inch), colour coding: green
Sampling fitting set with heater, PVC,
white
Order no.: 908727
For creating the pipe system at temperatures down to - 30°C
(-22 °F).
Included in delivery
1 PVC T-piece including heating resistor and
suction port d=6.5 mm (0.26 inch), colour coding: white
Sampling fitting set with heater, PVC,
black
Order no.: 908728
For creating the pipe system at temperatures down to - 30°C
(-22 °F).
Included in delivery
1 PVC T-piece including heating resistor and
suction port d=6.7 mm (0.26 inch), colour coding: black
Sampling fitting set with heater, PVC,
violet
Order no.: 908729
For creating the pipe system at temperatures down to - 30°C
(-22 °F).
Included in delivery
1 PVC T-piece including heating resistor and
suction port d=6.9 mm (0.27 inch), colour coding: violet
Sampling fitting set with heater, PVC,
brown
Order no.: 908730
For creating the pipe system at temperatures down to - 30°C
(-22 °F).
Included in delivery
1 PVC T-piece including heating resistor and
suction port d=7.1 mm (0.28 inch), colour coding: brown
Cable connector set, PVC
Order no.: 908731
P31.313.820en / 02.13
For creating the pipe system in refrigerated warehouses.
Silicone wire, black
Order no.: 908732
For connecting the heaters, single-lead.
Included in delivery
1 packaging unit with 100 m (3937 inch)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 7 - 17
Product Sheet | Detecon
Aspirating smoke detectors
Fittings
Silicone wire, white
Order no.: 908733
For connecting the heaters, single-lead.
Included in delivery
1 packaging unit with 100 m (3937 inch)
Filter box (small), d=25 mm (0.98 inch)
Order no.: 908734
For use in rooms with low temperatures and high dust levels.
Included in delivery
1 ¿lter box with built- in ¿lter
2 glands
Technical specifications
Enclosure
PVC grey
Temperature range
down to -30 °C (-22 °F)
80 x 82 x 85 mm (HxWxD)
3.2 x 3.2 x 0.8 inch (HxWxD)
Dimensions
Filter box (small)
Order no.: 908740
For use in the ¿lter box (small).
Technical specifications
Temperature range
down to - 30 °C (-22 °F)
80 x 80 x 20 mm (HxWxD)
3.2 x 3.2 x 0.8 inch (HxWxD)
Dimensions
Filter box (large) d=25
Order no.: 908735
For use in rooms with high dust levels.
Included in delivery
1 ¿lter box with ¿lter mat block, ¿ne stage
2 glands
Technical specifications
Enclosure
P31.313.820en / 02.13
Temperature range
Dimensions
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
PVC grey
Normal
120 x 122 x 85 mm (HxWxD)
4.7 x 4.8 x 3.4 inch (HxWxD)
Chapter 7 - 18
Product Sheet | Detecon
Aspirating smoke detectors
Fittings
Filter mat block fine stage
Order no.: 908741
For use in the ¿lter box (large).
Technical specifications
Temperature range
Normal
117 x 80 x 80 mm (HxWxD)
4.6 x 3.2 x 3.2 inch (HxWxD)
Dimensions
Filter active detector
Order no.: 900341
Air ¿lter for use in Minimax aspirating ¿re detection systems
in case of polluted ambient air.
Spare parts
Replacement kit ¿lter active detector
consisting of 1 coarse ¿lter mat, 1 ¿ne ¿lter and
1 infusion ¿lter 5 —m (for AMX detectors only)
902471
Technical specifications
Enclosure
Temperature range
Relative humidity
(IEC721-3-3)
IP rating (EN 60529)
Polycarbonate, RAL7035 - light grey
-5 °C to +65 °C
(+23 °F to +149 °F)
max. 98 %, condensation on the ¿lter
mats must be ruled out
IP65
Weight
370 g (0.8 lbs)
122 x 190 x 85 mm (HxWxD)
4.8 x 7.5 x 3.4 inch (HxWxD)
Dimensions
Dust trap box d=25 mm (0.98 inch)
Order no.: 908736
For use in rooms with high dust levels.
Included in delivery
1 dust trap
2 glands
Technical specifications
Enclosure
P31.313.820en / 02.13
Dimensions
PVC grey
240 x 250 x 90 mm (HxWxD)
9.5 x 9.8 x 3.5 inch (HxWxD)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 7 - 19
Product Sheet | Detecon
Aspirating smoke detectors
Fittings
Dust separator, cyklone d=25 mm
(0.98 inch)
Order no.: 908737
For use in rooms with high dust levels.
Smoke and water separator for aspirating smoke detectors.
Filterless separation of granular foreign matter with a particle
size exceeding 100 ȝ or liquid aerosols.
Included in delivery
1 dust and cyclone separator with adapters for installation in
sensor pipe systems d=25 mm (0.98 inch)
Technical specifications
Enclosure
Automatic blow-out device ADB 01A
PVC grey
Order no.: 908700
For aspirating smoke detectors for use in rooms with very
high dust levels.
For the automatic cleaning (blowing out) of the sensor pipe
system using compressed air.
Technical specifications
Operating voltage
15 - 30 V DC
Compressed-air port
Water retaining box, standard
Constant, approx. 4 bar
Order no.: 908738
For use with aspirating smoke detectors in rooms with high
humidity.
Included in delivery
1 water retaining box, standard
1 gland
1 T-piece for connection to the sensor pipe
d=25 mm (0.98 inch)
Technical specifications
Enclosure
P31.313.820en / 02.13
Dimensions
PVC grey
390 x 250 x 90 mm (HxWxD)
15.4 x 9.8 x 3.5 inch (HxWxD)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 7 - 20
Product Sheet | Detecon
Aspirating smoke detectors
Fittings
Detonation flame arrester
Order no.: 908739
For detection in hazard areas zone 1 (category 2G)
and zone 2 (category 3G) in accordance with the Directive
94/9/EC (ATEX 100a). BAM and TÜV-certi¿ed (TÜV = German
Inspection Authority) and approved for products of explosion
group IIC, up to a permissible standard gap width of >= 0.29
mm (1.14 inch). The aspirating smoke detector needs to be
mounted outside the potentially explosive area.
Included in delivery
1 explosion and detonation arrester
2 glands
Technical specifications
Enclosure
P31.313.820en / 02.13
Dimensions
PVC grey
390 x 250 x 90 mm (HxWxD)
15.4 x 9.8 x 3.5 inch (HxWxD)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 7 - 21
Product Sheet | Detecon
Aspirating smoke detectors
OneU®
OneU active extinguishing system
Order no.: 888840
The OneU is a compact extinguishing system in 19” format
with a height unit of only 44 mm. This mini extinguishing
system incorporates a central microprocessor unit, a
complete smoke aspiration system and a Novec™ 1230
extinguishant container for an extinguishing volume of 2.8 m³
(98.9 cubic foot). The smoke aspiration system is equipped
with two optical smoke detectors for reliable ¿re detection.
Power is supplied by a built-in power supply unit with an
input voltage range of 100 to 240 V AC and interruption-free
emergency power supply of 4 hours.
Application
Product features
•
•
•
•
•
•
Compact and space-ef¿cient design.
Fire detection and ¿re ¿ghting by one device directly on
and in the protected site.
Expandable by networking with slave extinguishing
modules for protecting up to four other sites
Residue-free extinguishing agent Novec™ 1230 from
3M™.
Easy to mount due to use of international standard 19"
technology.
Minimal maintenance required.
Included in delivery
Technical specifications
Detection method
Rated voltage
Power consumption
Emergency power supply
IP rating
Ambient temperature
Humidity
Ports
Display features
Aspiration tube
AirÀow monitoring
P21.250.111en / 01.14
Extinguishing agent
Protected volume
Weight
Enclosure dimensions
The ideal area of application for the OneU are spaces with
a self-contained atmosphere, as found in server, network,
modem and IT cabinets, modem and machine control
cabinets, high- and low-voltage cabinets, and telephone
distribution cabinets. The smoke aspiration system takes
air samples from the entire cabinet volume and conveys
them past the two sensitive smoke detectors. When the
pre-alarm threshold is reached, shutdown measures can
be initiated. If the smoke concentration continues to rise,
the extinguishant container is triggered by the ¿re alarm
threshold. The extinguishing agent is discharged, gasi¿ed at
the discharge nozzle and distributed effectively in the cabinet.
OneU active extinguishing system
888840
2 optical smoke detectors
100/240 V AC, 50/60 Hz
100 VA to 200 VA
approx. 4 hrs
IP 20
+10 °C to +35 °C (operation)
+50 °F to +95 °F (operation)
-20 °C to +65 °C (storage)
-4 °F to +149 °F) (storage)
Up to 96 %, no condensation
4 dry changeover contacts
Pre-alarm, ¿re, extinguish,
group fault, for 24 V 0.5 A
1 LCD with text display
1 green LED “Operation”
1 red LED “Alarm”
1 yellow LED “Group fault”
1 yellow LED “Power supply fault”
Plug-in system 22 mm (0.86 inch)
Not included in delivery
Aspiration tube system
907061
Optional accessories
OneU ED extinguishing module
889215
Notes
Door contact switches 889337 with retainers are to be
provided by the customer.
OneU can perform ¿re detection monitoring for up to ¿ve
server cabinets, but not selectively.
One OneU active extinguishing system can control up to
4 more extinguishing modules.
Approvals / marking
Approx. +/- 10 % volumetric Àow rate
NovecTM 1230
for a cabinet volume
of max. 2.8 m3 (98.9 cubic foot)
approx. 15 kg (33 lbs)
with extinguishing agent
19”, 1U, 640 mm (25.2 inch) deep
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 7 - 22
Product Sheet | Detecon
Aspirating smoke detectors
OneU®
OneU DD aspiration smoke detector
Order no.: 907085
The OneU DD is a smoke aspiration system in 19” format
with a height unit of only 44 mm. The device incorporates
a central microprocessor unit, a smoke aspiration system
and a CAN bus interface for the external control of 4 OneU
ED extinguishing systems. The smoke aspiration system
is equipped with two optical smoke detectors for reliable
¿re detection. Power is supplied by a built-in power supply
unit with an input voltage range of 100 to 240 V AC and
interruption-free emergency power supply of 4 hours.
Application
Product features
•
Compact and space-ef¿cient design.
•
Fire detection directly on and in the protected site.
•
Expandable by networking with OneU ED (slave extinguishing system) for protecting up to four other sites.
•
Easy to mount due to use of international standard 19"
technology.
•
Minimal maintenance required.
Technical specifications
Detection method
Rated voltage
Power consumption
Operating voltage
Emergency power supply
IP rating
Ambient temperature
Humidity
Ports
Display features
Aspiration tube
AirÀow monitoring
Weight
2 optical smoke detectors
The ideal areas of application for the OneU DD are spaces
with a self-contained atmosphere, as found in server,
network, modem and IT cabinets, modem and machine
control cabinets, high- and low-voltage cabinets, and
telephone distribution cabinets. The smoke aspiration
system takes air samples from the entire cabinet volume
and conveys them past the two sensitive smoke detectors.
When the pre-alarm threshold is reached, shutdown
measures can be initiated. If the smoke concentration
continues to rise, the ¿re alarm is triggered by the ¿re alarm
threshold and any extinguishing modules connected are
triggered.
Included in delivery
OneU DD aspiration smoke detector
132 VA to 264 VA
24 V DC
approx. 4 hrs
IP 20
+10 °C to +35 °C (operation)
+50 °F to +95 °F (operation)
-20 °C to +65 °C (storage)
-4 °F to +149 °F) (storage)
Up to 96 %, no condensation
4 dry changeover contacts
Pre-alarm, ¿re, extinguish,
group fault, for 24 V 0.5 A
1 LCD with text display
1 green LED “Operation”
1 red LED “Alarm”
1 yellow LED “Group fault”
1 yellow LED “Power supply fault”
Plug-in system 22 mm
Not included in delivery
Aspiration tube system
907061
Optional accessories
OneU ED extinguishing module
889215
Notes
Door contact switches 889337 with retainers are to be provided by the customer.
OneU can perform ¿re detection monitoring for up to ¿ve
server cabinets, but not selectively.
One OneU DD can control up to 5 OneU ED modules.
Approvals / marking
Approx. +/- 10 % volumetric Àow rate
approx. 8 kg (17.6 lbs)
19”, 1U, 480 mm (18.9 inch) deep
P21.250.111en / 01.14
Enclosure dimensions
907085
100/240 V AC, 50/60 Hz
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 7 - 23
Product Sheet | Detecon
Aspirating smoke detectors
OneU®
OneU ED NG extinguishing module
Order no.: 889215
The OneU ED NG is an extinguishing system in 19”
format with a height unit of only 44 mm (1.73 inch). The
extinguishing agent used is NovecTM 1230, a chemicallyacting liquid which vaporises upon being discharged from
a nozzle and takes effect in gaseous form. The device
incorporates an extinguishing agent tank, a microprocessor
system and a CAN bus interface for networking with a higherlevel OneU or OneU DD (master device). Extinguishing
is triggered by the master device only. Up to 4 OneU ED
NG units can be networked, which are then activated in
a cascade if extinguishing is triggered, with a delay of 1 s
between each unit. Power is supplied from the master device,
including the 4-hour emergency power supply. All necessary
device information is displayed on the master device. The dry
contacts can be tapped on the device itself.
Product features
•
Compact and space-ef¿cient design.
•
Fire extinguishing directly on and in the protected site.
•
Can be expanded by networking with up to 4 OneU ED
extinguishing systems.
•
Easy to mount due to use of international standard
19" technology.
•
Minimal maintenance required.
Technical specifications
Extinguishing agent
Rated voltage
Operating voltage
Emergency power supply
IP rating
Ambient temperature
Humidity
Ports
Display features
Fire detection
Control of extinguishing
system
Protected volume
Weight
The OneU ED is part of the OneU ¿re protection device
series, acting as an additional extinguishing system for
expanding the extinguishing capacity by 2.8 m³ (98.9 cubic
foot). Smoke detection is always performed by the master
device.
Included in delivery
NovecTM 1230
OneU ED extinguishing module
889215
24 V DC
24 V DC -3/+5 V
Up to 4 hrs from the master device
IP 20
+10 °C to +35 °C (operation)
+50 °F to +95 °F (operation)
-20 °C to +65 °C (storage)
-4 °F to +149 °F) (storage)
Up to 96 %, no condensation
4 dry changeover contacts
Pre-alarm, ¿re, extinguish,
group fault, for 24 V 1 A
In the master device only
(OneU or OneU DD)
By the master device
Optional accessories
OneU active extinguishing system
OneU DD aspiration smoke detector
888840
907085
Notes
Door contact switches 889337 with retainers are to be provided by the customer.
The OneU ED can only be operated together with a OneU
active extinguishing system or a OneU DD, see manual.
Approvals / marking
By the master device
max. 2.8 m3 (98.9 cubic foot)
approx. 12 kg (26.4 lbs)
with extinguishing agent
19”, 1U, 640 mm (25.2 inch) deep
P21.250.111en / 01.14
Enclosure dimensions
Application
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 7 - 24
Product Sheet | Detecon
Special detectors
Linear smoke detectors
FireRay 5000
Order no.: 908458
The FireRay 5000 is a motorised, linear smoke detector
with automatic alignment and optical rays. The FireRay
5000 consists of an infrared transmitter and an infrared
receiver within the same device. It functions by conducting
a clearly distinguished ray to a reflective prism. If the ray
meets smoke, a decrease in performance is recorded and
an alarm signal is triggered soon as this drops below a
pre-programmed limit value. As soon as the laser is used to
roughly align the ray, the Auto-Align takes over to move the
ray into the optimal position. This is an ideal solution for the
protection of wide areas in which the use of standard detector
technology would pose significant costs.
Product features
•
•
•
•
•
•
•
Integrated laser.
One system controller unit can be used to control and
monitor up to two detector heads.
Monitored area min. 8 m (315 inch) to max. 100 m (3937
inch) depends on the used number of prism reflectors.
Auto-Align: automatic ray alignment.
Auto-Optimise: adjustment to compensate for building
movement and impurities.
2-wire interface between system control device and
detector.
Integrated event log for 50 events per detector head.
Included in delivery
1 system controller unit
1 detector head
1 reflector
Approvals / marking
G 208017
0832-CPD-0565
Technical specifications
Optical wavelength
Ambient temperature
Storage temperature
Relative humidity
Operating voltage
Rated voltage
Rated current consumption
with 1 detector head
Rated current consumption
with 2 detector heads
Current consumption
alignment mode
24 V DC
5 - 6 mA
7.5 - 8.5 mA
35 - 37 mA
Relay contact voltage
2 alarm relays
2 fault relays
30 V DC
Relay contact current
100 mA
Outputs
Response sensitivity
IP rating
P31.314.101en / 01.14
850 nm
-10 °C to +55 °C
(+14 °F to +131 °F)
- 40 °C to + 85 °C
(- 40 °F to +185 °F)
max. 93 %,
no condensation
14 - 36 V DC
adjustable 10 - 60 %
IP 54
Weight (system control)
Dimensions
(system control)
Weight (detector head)
Dimensions detector head
Dimensions prism reflectors
1000 g (2.2 lbs)
202 x 230 x 87 mm (WxHxD)
7.95 x 9.05 x 3.42 inch (WxHxD)
500 g (1.1 lbs)
134 x 131 x 134 mm (WxHxD)
5.27 x 5.16 x 5.27 inch (WxHxD)
100 x 100 x 10 mm (WxHxD)
3.9 x 3.9 x 0.4 inch (WxHxD)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 8 - 1
Product Sheet | Detecon
Special detectors
Linear smoke detectors, accessories
Universal mounting bracket
Order no.: 908460
Bracket pivots for accurate alignment of FireRay 5000 smoke
detector or reflector.
Technical specifications
Weight
200 g (0.4 lbs)
135 x 135 x 71 mm (WxHxD)
5.3 x 5.3 x 2.8 inch (WxHxD)
Dimensions
Long range reflector kit (3 prisms)
Order no.: 908459
3 additional reflectors for use when the installation is between
50 and 100 m (1968 and 3937 inch) from detector head.
Technical specifications
Weight (1 reflector)
100 g (0.2 lbs)
100 x 100 x 10 mm (WxHxD)
3.9 x 3.9 x 0.4 inch (WxHxD)
Dimensions (1 reflector)
Detector head
Order no.: 908661
Additional detector head with reflector for the FireRay 5000.
Obscuration filter
Order no.: 908461
Obscuration test filter to perform the sensitivity test.
P31.314.104en / 02.13
Single reflector alignment adapter
Order no.: 908662
Comes pre-drilled to mount 1 reflector. Designed to mount on
the universal mounting bracket.
Not included in delivery
Universal holder and reflector.
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 8 - 2
Product Sheet | Detecon
Special detectors
Linear smoke detectors, accessories
4 reflectors alignment adapter
Order no.: 908663
Comes pre-drilled to mount 4 reflectors. Designed to mount
on the universal mounting bracket.
Not included in delivery
Universal holder and reflectors.
Reflector wall bracket
Order no.: 908664
Comes pre-drilled to mount (1 up to 50 m (1968 inch)) or 4
(from 50 m (1968 inch) to 100 m (3937 inch)) reflectors. Hole
pattern on side mounting flange similar to unistrut.
System controller back box
Order no.: 908665
Includes conduit knock-outs on top and bottom. Surface or
flush mount. Will mount to single gang, double gang or 4
square box.
Note
Is intended for use on the US market.
System controller semi flush trim plate
Order no.: 908666
Mounts on system controller back box for semi flush
installation.
Note
Is intended for use on the US market.
Detector head back box
Order no.: 908667
P31.314.104en / 02.13
Back box includes knock-outs on all four sides. Will mount
over single gang, double gang or 4 square box.
Note
Is intended for use on the US market.
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 8 - 3
Product Sheet | Detecon
Special detectors
Linear smoke detectors, accessories
Detector head cover plate
Order no.: 908668
Use with detector head back box. Pre-drilled to mount the
detector head.
Not included in delivery
Flush-mounted enclosure for detector.
Note
Is intended for use on the US market.
Ceiling pendant mount bracket
Order no.: 908669
P31.314.104en / 02.13
Comes pre-drilled to mount detector head. Can be used
for single or bidirectional applications. Includes 2 mounting
plates and 1 blank cover.
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 8 - 4
Product Sheet | Detecon
Special detectors
Cyklone monitoring
VMX 3001-S
VMX 3001-E
Order no.: 903121
Order no.: 903122
In the timber industry and in milling plants, especially in the
chipboard industry, frequent clogging of cyclones occurs due
to material deposits which result in a sudden emission of
material on the clean air side. In order to detect this material
accumulation in the initial stage, thus preventing breakdowns
and pollutant emissions, special sensors are installed in the
conical section of the cyclone.
Monitoring occurs according to the light barrier principle with
one infrared emitter VMX 3001-S and on the opposite side
one receiver VMX 3001-E.
Product features
Not included in delivery
•
Support ball mounting
Fitting tool
Support adapter assembly with washer
Support adapter assembly with washer
250 °C (482 °F)
Air flushing single hole
Unproblematic alignment of the detectors by means of a
spherical joint.
Technical specifications
Detection method
Viewing angle
Spectral sensitivity
Operating voltage
Alarm current consumption
Alarm indication
Electrostatic shielding
Operating temperature
IP rating (EN 60529)
Enclosure material
Relative humididy
(IEC721-3-3)
Weight
950 nm
24 V DC (VMX 3001-S)
7.6-13.2 V DC (VMX 3001-E)
25 mA (VMX 3001-S)
approx. 18 mA (VMX 3001-E)
1 LED red
required
-20 °C to +70 °C
(-4 °F to +158 °F)
IP 65
Diecast aluminium,
RAL5009, blue
max. 95 % at 35 °C (+95 °F)
no condensation
650 g (1.4 lbs) VMX 3001-S
900 g (2 lbs) VMX 3001-E
80 x 75 x 57 mm (WxHxD)
3.2 x 3 x 2.2 inch (WxHxD)
VMX 3001-S
125 x 80 x 57 mm (WxHxD)
4.9 x 3.2 x 2.2 inch (WxHxD)
VMX 3001-E
800034
907822
Connection / mounting
Connection cable standard detector
2-lead
Conductor cross-section
max. 2.5 mm2 (0.004 square inch)
Recommended cable with shielding braid
606061
LIYCY grey, 5x0.5 mm2 (0.0008 square inch)
Cable gland
M16x1.5, brass galv. nickel-plated, EMV
Approvals / marking
G 208191
P31.314.801en / 02.13
Dimensions
Infrared light barrier according to
the transmitted light method
60 ° in case of air flushing
903123
843774
891848
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 8 - 5
Product Sheet | Detecon
Special detectors
Cyklone monitoring Ex
VMX 3001-S Ex Dust
VMX 3001-E Ex Dust
Order no.: 907434
Order no.: 907433
In the timber industry and in milling plants, especially in the
chipboard industry, frequent clogging of cyclones occurs due
to material deposits which result in a sudden emission of
material on the clean air side. In order to detect this material
accumulation in the initial stage, thus preventing breakdowns
and pollutant emissions, special sensors are installed in the
conical section of the cyclone.
These detector versions are suitable as category 1D/3D devices for use in areas of the zones 20, 21 and 22 where there
is risk of dust explosion.
Product features
•
Easy alignment of the detectors by means of a spherical
joint.
Technical specifications
Detection method
Viewing angle
Spectral sensitivity
Operating voltage
Alarm current consumption
Alarm indication
Electrostatic shielding
Operating temperature
IP rating (EN 60529)
Enclosure material
Relative humididy
(IEC721-3-3)
Weight
950 nm
24 V DC (VMX 3001-S)
7,6-13,2 V DC (VMX 3001-E)
25 mA (VMX 3001-S)
approx. 18 mA (VMX 3001-E)
1 LED red
required
-20 °C to +70 °C
(-4 °F to +158 °F)
IP 65
Diecast aluminium,
RAL5009, blue
max. 95 % at 35 °C (+95 °F)
no condensation
650 g (1.4 lbs) VMX 3001-S
900 g (2 lbs) VMX 3001-E
80 x 75 x 57 mm (WxHxD)
3.2 x 3 x 2.2 inch (WxHxD)
VMX 3001-S
125 x 80 x 57 mm (WxHxD)
4.9 x 3.2 x 2.2 inch (WxHxD)
VMX 3001-E
Support ball mounting
Fitting tool
Support adapter assembly with washer
Support adapter assembly with washer
250 °C (482 °F)
Air flushing single hole
903123
843774
891848
800034
907822
Connection / mounting
Connecting cable standard detector
2-lead
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Recommended cable with shielding braid
606061
LIYCY grey, 5x0.5 mm2 (0.0008 square inch)
Cable gland
M16x1.5, brass galv. nickel-plated, EMV, Ex
Approvals / marking
Ex conformity in acc. with 94/9/EG:
x II 1/3D Ex tD A20/22 IP65 T100°C (-E)
x II 1/3D Ex tD A20/22 IP65 T136°C (-S)
Type examination certificate:
BVS 09 ATEX E025
G 208191
P31.314.802en / 02.13
Dimensions
Infrared light barrier according to
the transmitted light method
60 ° in case of air flushing
Not included in delivery
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 8 - 6
Product Sheet | Detecon
Means of alarm
Audible
Sounder ROLP MX
Order no.: 908631
Audible noti¿cation device for signalling ¿re hazards,
approved according EN 54-3 and VdS. The alarm signalling
device offers a selection of 32 tones and the con¿guration
is carried out via a ¿ve -pin DIP switch. Up to two different
acoustic signals can be con¿gured via wiring. The volume
can be adjusted via a DIP-switch.
Included in delivery
Technical specifications
Enclosure material
IP rating
ABS, red
IP 65
Rated voltage
Operating voltage
Rated current consumption
Tones
24 V DC
9 V - 28 V DC
Ambient temperature
Relative humididy
2
-25 °C to +70 °C
(-13 °F to +158 °F)
max. 95 %
Sound pressure
up to 102 dB (A) 1 m
Weight
250 g (0.6 lbs)
93 x 93 mm (WxH)
3.7 x 3.7 inch (WxH)
Dimensions
Not included in delivery
Mounting hardware
Cable glands
32 mA
32
Tone stages
1 Sounder ROLP MX
Connection / mounting
Recommended cable
Conductor cross-section
2-lead
max. 2.5 mm2 (0.004 square inch)
Note
The sounder can be operated via the voltage increase function as well as via the voltage reversal function at the FMZ
5000 and FMZ 5000 mod S control panels. The device has
an integrated reverse polarity protection diode.
Approvals / marking
0832-CPD-0128
P31.320.110 - 4en / 02.14
G 206019
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 1
Product Sheet | Detecon
Means of alarm
Audible
Sounder YO4 MX
Order no.: 893559
Audible noti¿cation device for signalling ¿re hazards,
approved according EN 54-3 and VdS. Equipped with an
electronic module for operation directly on a primary control
group of the ¿re alarm panel via a voltage increase.
Included in delivery
Technical specifications
Enclosure material
IP rating
Ambient temperature
Storage temperature
Relative humidity
ABS, red
IP 54
-25 °C to +55 °C
(-13 °F to +131 °F)
-40 °C to +70 °C
(-40 °F to +158 °F)
max. 90 %
Rated voltage
24 V DC
Operating voltage
18 V - 30 V DC
Rated current consumption
100 %
Tones
32
Sound range
Weight
Dimensions
Not included in delivery
Mounting hardware
Cable glands
Connection / mounting
Recommended cable
Conductor cross-section
2-lead
max. 2.5 mm2 (0.004 square inch)
110 mA
Duty cycle
Sound pressure
1 Sounder YO4 MX
up to 106 dB (A) 1 m
approx. 1300 m2
(13993 square foot),
Ø 40 m (1575 inch)
240 g (0.5 lbs)
88 x 88 x 81 mm (WxHxD)
3.5 x 3.5 x 3.2 inch (WxHxD)
Note
The sounder can be operated via the voltage increase
function as well as via the voltage reversal function at the
FMZ 5000 and FMZ 5000 mod S control panels. The device
has an integrated reverse polarity protection diode.
Approvals / marking
0086-CPD-96705
P31.320.110 - 2en / 02.14
G 209134
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 2
Product Sheet | Detecon
Means of alarm
Audible
Sounder YO5 MX
Order no.: 893547
Audible noti¿cation device for signalling ¿re hazards,
approved according EN 54-3 and VdS. Equipped with an
electronic module for operation directly on a primary control
group of the ¿re alarm panel via a voltage increase.
Included in delivery
Technical specifications
Enclosure material
IP rating
Ambient temperature
Storage temperature
Relative humidity
ABS, red
IP 54
-25 °C to +55 °C
(-13 °F to +131 °F)
-40 °C to +70 °C
(-40 °F to +158 °F)
max. 90 %
Rated voltage
24 V DC
Operating voltage
18 V - 30 V DC
Rated current consumption
90 mA
Duty cycle
100 %
Tones
32
Sound pressure
Sound range
Weight
Dimensions
up to 110 dB (A) 1 m
approx. 1300 m2
(13993 square foot),
Ø 40 m (1575 inch)
710 g (1.6 lbs)
134 x 134 x 128 mm (WxHxD)
5.3 x 5.3 x 5.6 inch (WxHxD)
1 Sounder YO5 MX
Not included in delivery
Mounting hardware
Cable glands
Connection / mounting
Recommended cable
Conductor cross-section
2-lead
max. 1.5 mm2 (0.002 square inch)
Note
The sounder can be operated via the voltage increase
function as well as via the voltage reversal function at the
FMZ 5000 and FMZ 5000 mod S control panels. The device
has an integrated reverse polarity protection diode.
Approvals / marking
0086-CPD-96705
P31.320.110 - 2en / 02.14
G 209134
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 3
Product Sheet | Detecon
Means of alarm
Audible
Sounder PA 1
NEW Order no.: 917456
Audible noti¿cation device for signaling ¿re hazards,
approved according EN 54-3 and VdS. The sounder is
impressive due to its safe and simple mounting with external
lugs or internal holes, simple electrical connection on the
bottom of the casing. A potentiometer can be used to adjust
the volume.
Included in delivery
Technical specifications
Enclosure material
PC/ABS Blend, red
IP rating
IP 66
-40 °C to +55 °C
(-40 °F to +131 °F)
-40 °C to +70 °C
(-40 °F to +158 °F)
max. 90 %
Ambient temperature
Storage temperature
Relative humidity
Rated voltage
24 V DC
Operating voltage
Rated current consumption
10 V - 57 V DC
80
Sound pressure
Weight
Dimensions
Not included in delivery
Mounting hardware
Cable glands
Connection / mounting
Recommended cable
Conductor cross-section
2-lead
max. 2.5 mm2 (0.004 square inch)
at 24 V DC 50 mA
Tones
Tone stages
1 Sounder PA 1
3 additional externally selectable
up to 105 dB (A) 1 m
270 g (0.59 lbs)
109.5 x 86 x 80.6 mm (WxHxD)
4.3 x 3.4 x 3.2 inch (WxHxD)
Note
The sounder has three pre-cut M20 cable openings. It can
only be operated via the voltage reversal function at the
FMZ 5000 and FMZ 5000 mod S control panels. The device
has an integrated reverse polarity protection diode.
Approvals / marking
0786-CPD-21182
P31.320.110 - 8en / 02.14
G 212115
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 4
Product Sheet | Detecon
Means of alarm
Audible
Sounder PA 5
NEW Order no.: 917457
Audible noti¿cation device for signaling ¿re hazards,
approved according EN 54-3 and VdS. The sounder is
impressive due to its safe and simple mounting with external
lugs or internal holes, simple electrical connection on the
bottom of the casing. A potentiometer can be used to adjust
the volume.
Included in delivery
Technical specifications
Enclosure material
PC/ABS Blend, red
IP rating
IP 66
-40 °C to +55 °C
(-40 °F to +131 °F)
-40 °C to +70 °C
(-40 °F to +158 °F)
max. 90 %
Ambient temperature
Storage temperature
Relative humidity
Rated voltage
24 V DC
Operating voltage
Rated current consumption
10 V - 57 V DC
80
Sound pressure
Weight
Dimensions
Not included in delivery
Mounting hardware
Cable glands
Connection / mounting
Recommended cable
Conductor cross-section
2-lead
max. 2.5 mm2 (0.004 square inch)
at 24 V DC 50 mA
Tons
Tone stages
1 Sounder PA 5
3 additional externally selectable
up to 107 dB (A) 1 m
643 g (1.41 lbs)
143 x 135 x 132 mm (WxHxD)
5.6 x 5.3 x 5.2 inch (WxHxD)
Note
The sounder has three pre-cut M20 cable openings. It can
only be operated via the voltage reversal function at the
FMZ 5000 and FMZ 5000 mod S control panels. The device
has an integrated reverse polarity protection diode.
Approvals / marking
0786-CPD-21182
P31.320.110 - 8en / 02.14
G 212115
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 5
Product Sheet | Detecon
Means of alarm
Audible
Sounder A105N
NEW Order no.: 917458
Audible noti¿cation device for signaling ¿re hazards,
approved according EN 54-3 and VdS. The sounder is
impressive due to its safe and simple mounting with external
lugs or internal holes. A potentiometer can be used to adjust
the volume.
Included in delivery
Technical specifications
Enclosure material
IP rating
Ambient temperature
Storage temperature
Relative humidity
ABS, red
IP 66
-25 °C to +55 °C
(-13 °F to +131 °F)
-40 °C to +70 °C
(-40 °F to +158 °F)
at 20 °C max. 90 %
Rated voltage
24 V DC
Operating voltage
Rated current consumption
10 V - 30 V DC
at 24 V DC 25 mA
Tones
32
Tone stages
Sound pressure
Weight
Dimensions
3
up to 112 dB (A) 1 m
750 g (1.65 lbs)
144 x 130 x 133.5 mm (WxHxD)
5.7 x 5.1 x 5.2 inch (WxHxD)
1 Sounder A105N
2 Blanking plugs M 20
Not included in delivery
Mounting hardware
Cable glands
Connection / mounting
Recommended cable
Conductor cross-section
2-lead
max. 2.5 mm2 (0.004 square inch)
Note
The sounder has two M20 cable openings. It can only be
operated via the voltage reversal function at the FMZ 5000
and FMZ 5000 mod S control panels. The device has an
integrated reverse polarity protection diode.
Approvals / marking
0786-CPD-20257
P31.320.110 - 9en / 02.14
G 205121
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 6
Product Sheet | Detecon
Means of alarm
Audible
Sounder Symphoni HO WP
NEW Order no.: 917459
Audible noti¿cation device for signaling ¿re hazards, approved according EN 54-3 and VdS. A potentiometer can be
used to adjust the volume.
Included in delivery
Technical specifications
Enclosure material
ABS, red
IP rating
IP 66
-25 °C to +70 °C
(-13 °F to +158 °F)
-40 °C to +70 °C
(-40 °F to +158 °F)
max. 90 %
Ambient temperature
Storage temperature
Relative humidity
Rated voltage
24 V DC
Operating voltage
18 V - 28 V DC
Rated current consumption
32
Tone stages
Weight
Dimensions
Not included in delivery
Mounting hardware
Cable glands
Connection / mounting
Recommended cable
Conductor cross-section
2-lead
max. 2.5 mm2 (0.004 square inch)
260 mA
Tones
Sound pressure
1 Sounder Symphoni HO WP
2
up to 120 dB (A) 1 m
680 g (1.5 lbs)
110 x 110 x 105 mm (WxHxD)
4.3 x 4.3 x 4.1 inch (WxHxD)
Note
The sounder can only be operated via the voltage reversal
function at the FMZ 5000 and FMZ 5000 mod S control panels. The device has an integrated reverse polarity protection
diode.
Approvals / marking
0832-CPD-0142
P31.320.110 - 10en / 02.14
G 206027
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 7
Product Sheet | Detecon
Means of alarm
Audible
Sounder DS10 MX
Order no.: 801175
Audible noti¿cation device for signalling ¿re hazards,
approved according EN 54-3 and VdS. Equipped with an
electronic module for operation directly on a primary control
group of the ¿re alarm panel via a voltage increase.
Included in delivery
Technical specifications
Enclosure material
IP rating
Ambient temperature
Storage temperature
Relative humidity
Diecast aluminium, red
IP 67
-25 °C to +55 °C
(-13 °F to +131 °F)
-40 °C to +70 °C
(-40 °F to +158 °F)
max. 90 %
Rated voltage
24 V DC
Operating voltage
19 V - 29 V DC
Rated current consumption
approx. 420 mA
Duty cycle
1 Sounder DS10 MX
1 Cable gland M20 x 1.5
1 Blanking plug M20
Not included in delivery
Mounting hardware
Connection / mounting
Recommended cable
Conductor cross-section
2-lead
max. 2.5 mm2 (0.004 square inch)
100 %
Tones
32
Sound pressure
Sound range
Weight
Dimensions
up to 110 dB (A) 1 m
approx. 10000 m2 (6.2 miles),
Ø 116 m (4567 inch)
2200 g (4.9 lbs)
134 x 134 x 143 mm (WxHxD)
5.3 x 5.3 x 5.6 inch (WxHxD)
Note
The sounder can be operated via the voltage increase function as well as via the voltage reversal function at the FMZ
5000 and FMZ 5000 mod S control panels. The device has
an integrated reverse polarity protection diode.
Approvals / marking
0786-CPD-20005
P31.320.110 - 1en / 02.14
G 204031
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 8
Product Sheet | Detecon
Means of alarm
Audible
Sounder DS10 MX ext. tone selection
Order no.: 801176
Audible noti¿cation device for signalling ¿re hazards,
approved according EN 54-3 and VdS. Equipped with an
electronic module for operation directly on a primary control
group of the ¿re alarm panel via a voltage increase.
Product features
Included in delivery
•
1 Sounder DS10 MX ext. tone selection
1 Cable gland M20 x 1.5
1 Blanking plug M20
Sounder with external tone selection.
Technical specifications
Enclosure material
IP rating
Ambient temperature
Storage temperature
Relative humidity
Diecast aluminium, red
IP 67
-25 °C to +55 °C
(-13 °F to +131 °F)
-40 °C to +70 °C
(-40 °F to +158 °F)
max. 90 %
Rated voltage
24 V DC
Operating voltage
19 V - 29 V DC
Rated current consumption
approx. 420 mA
Duty cycle
100 %
Tones
32
Sound pressure
Sound range
Weight
Dimensions
up to 110 dB (A) 1 m
approx. 10000 m2
(107639 square foot),
Ø 116 m (4567 inch)
2200 g (4.9 lbs)
134 x 134 x 143 mm (WxHxD)
5.3 x 5.3 x 5.6 inch (WxHxD)
Not included in delivery
Mounting hardware
Connection / mounting
Recommended cable
2-lead
with function „ext. tone sel.2
3-lead
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Note
The sounder can be operated via the voltage increase function as well as via the voltage reversal function at the FMZ
5000 and FMZ 5000 mod S control panels. The device has
an integrated reverse polarity protection diode
Approvals / marking
0786-CPD-20005
P31.320.110 - 1en / 02.14
G 204031
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 9
Product Sheet | Detecon
Means of alarm
Audible addressable
Loop sounder LSX 278r
Order no.: 905805
Loop sounder for audible alarm noti¿cation, approved
according EN 54-3 in red colour. Addressing via built-in DIP
switches. Choice between two different tones, controlled via
the ¿re alarm panel.
Included in delivery
1 Loop sounder LSX 278r
Not included in delivery
Mounting hardware
Technical specifications
Connection / mounting
Material
PC
IP rating
IP 21C
Sound pressure
Up to 100 dB
Colour
red
Technology / protocol
Loop AP / XP95
Integrated isolator
no
10 °C to +55 °C
(+14 °F to +131 °F)
18 V - 28 V DC
Ambient temperature
Operating voltage
Operating (alarm) current
Dimensions
Approvals / marking
0832-CPD-0147
5 mA
Quiescent current
Weight
Cable recommendation standard
J-Y(St)Y -2x2x0.8 mm, red
747180
Recommended cable
2-lead
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Electrostatic shielding
not required
330 — A
290 g (0.6 lbs)
105 x 105 x 90 mm (W x H x D)
4.1 x 4.1 x 3.5 inch (W x H x D)
Loop sounder LSX 279W
Order no.: 905806
Colour: white
P31.320.110 - 3en / 01.14
Otherwise like Order no. 905805.
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 10
Product Sheet | Detecon
Means of alarm
Audible addressable
Loop sounder LSX 274r WP
Order no.: 905807
Loop sounder for audible alarm noti¿cation, approved according EN 54-3 in red colour. Addressing via built-in DIP
switches. For applications in rough environmental conditions
with increased protection rating IP 66. Choice between two
different tones, controlled via the ¿re alarm panel.
Included in delivery
Technical specifications
Enclosure material
IP rating
PC, red
IP 66
Colour
red
Technology / protocol
Integrated isolator
Ambient temperature
Operating voltage
Operating (alarm) current
Quiescent current
Sound pressure
Weight
Not included in delivery
Mounting hardware
Loop AP / XP95
no
-20 °C to +70 °C
(-4 °F to +158 °F)
18 V - 28 V DC
5 mA
330 —A
Connection / mounting
Cable recommendation standard
J-Y(St)Y -2x2x0.8 mm, red
747180
Recommended cable
2-lead
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Electrostatic shielding
not required
up to 100 dB
294 g (0.6 lbs)
110 x 110 x 113 mm (WxHxD)
4.3 x 4.3 x 4.5 inch (WxHxD)
Approvals / marking
0832-CPD-0147
P31.320.110 - 3en / 01.14
Dimensions
1 Loop sounder LSX 274r
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 11
Product Sheet | Detecon
Means of alarm
Audible addressable
Loop sounder LSX 001r
Order no.: 916281
Loop sounder for audible alarm noti¿cation, approved
according EN 54-3 and VdS with an integrated dual isolator
in red colour. Addressing via built-in DIP switches. Choice
between two different tones, controlled via the ¿re alarm
panel.
Included in delivery
1 Loop sounder LSX 001r
Not included in delivery
Mounting hardware
Technical specifications
Material
PC
IP rating
IP 65
Sound pressure
Colour
up to 100 dB
red
Technology / protocol
Integrated isolator
Tones
Ambient temperature
Operating voltage
Operating (alarm) current
Quiescent current
Weight
Dimensions
Loop sounder LSX 002w
Loop AP / XP95
yes
3
-25 °C to +70 °C
(-13 °F to +158 °F)
17 V - 28 V DC
Connection / mounting
Cable recommendation standard
J-Y(St)Y -2x2x0.8 mm, red
747180
Recommended cable
2-lead
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Electrostatic shielding
not required
Approvals / marking
G 212187
0832-CPD-1050
5 mA
333 —A
225 g (0.5 lbs)
97.5 x 104 mm (DxH)
3.8 x 4.1 inch (DxH)
Order no.: 916282
P31.320.110 - 3en / 01.14
Colour white. Otherwise like 916281.
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 12
Product Sheet | Detecon
Means of alarm
Audible, addressable
Base sounder BSX 300
Order no.: 901313
Base sounder for analog addressable detectors for acoustic
alarm generation approved according EN 54-3 and VdS with
dual isolator, in white. Addressing via built-in DIP switch.
Simple mounting and easy insertion of detectors by clockwork rotation with subsequent locking.
Cover available in red or white for use without detector.
Included in delivery
Technical specifications
Enclosure material
Technology / protocol
Integrated isolator
IP rating
Relative humidity
Operating temperature
Operating voltage
Rated current consumption
Operating pressure
Sound pressure
Weight
Dimensions
White polycarbonate
Loop AP / XP95
yes
IP 21D
0 to 95 %
no condensation
-20 °C to +60 °C
(-4 °F to +140 °F)
17 V - 28 V DC
200 —A
5 mA
up to 91 dB
140 g (0.3 lbs)
115 x 38 mm (DxH)
4.5 x 1.5 inch (DxH)
1 Base sounder BSX 300
1 Address card
Not included in delivery
Cover red
Cover white
912575
912576
Connection / mounting
Cable recommendation standard
J-Y(St)Y -2x2x0.8 mm, red
747180
Recommended cable
2-lead
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Electrostatic shielding
Not required
Approvals / marking
0832-CPD-0373
P31.320.110 - 5en / 01.14
G 207009
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 13
Product Sheet | Detecon
Means of alarm
Audible Ex
Sounder DS10 MX Ex
Order no.: 900282
Audible noti¿cation device for the signaling of ¿re hazards,
approved according EN 54-3 and VdS. The sounder is
especially suitable for use in industrial environments with
hazard areas in zone 2 as well as 22. Equipped with an
electronic module for operation directly on a primary control
group of the ¿re alarm panel via a voltage increase.
Product features
Included in delivery
•
1 Sounder DS10 MX Ex
1 Cable gland M20 x 1.5
1 Blanking plug M20
For use in Ex zones 2 and 22.
Technical specifications
Enclosure material
Diecast aluminium, red
IP rating
Ambient temperature
Storage temperature
Relative humidity
IP 67
-25 °C to +55 °C (T4)
-13 °F to +131 °F (T4)
-25 °C to +60 °C (T3)
-13 °F to +140 °F (T3)
-40 °C to +70 °C
-40 °F to +158 °F
max. 90 %
Rated voltage
24 V DC
Operating voltage
19 V - 29 V DC
Rated current consumption
420 mA
Duty cycle
100 %
Tones
Not included in delivery
Mounting hardware
Connection / mounting
Recommended cable
Conductor cross-section
2-lead
max. 2.5 mm2 (0.004 square inch)
Note
The sounder can be operated via the voltage increase
function as well as via the voltage reversal function at the
FMZ 5000 and FMZ 5000 mod S control panels. The device
has an integrated reverse polarity protection diode.
32
Sound pressure
up to 110 dB (A) 1 m
approx. 10000 m2
(107639 square foot),
Ø 116 m (4566 inch)
2200 g (4.9 lbs)
134 x 134 x 143 mm (WxHxD)
5.3 x 5.3 x 5.6 inch (WxHxD)
Sound range
Weight
Dimensions
Approvals / marking
Ex classi¿cation:
P31.320.120 - 2en / 02.14
x II 3G Ex nAc IIC T4 -25°C ” Ta ” +55°C
x II 3G Ex nAc IIC T3 -25°C ” Ta ” +60°C
x II 3D Ex tc IIIB T135°C IP67 -25°C ” Ta ” +60°C
Ex conformity Russia in acc. with TP TC 012/2011:
2Ex nAc IIC T3/T4
Ex tc IIIB T135°C IP65
G 204031
0786-CPD-20005
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 14
Product Sheet | Detecon
Means of alarm
Audible Ex
Sounder DS10 MX Ex, ext. tone selection
Order no.: 900283
Audible noti¿cation device for the signaling of ¿re hazards
approved according EN 54-3 and VdS. The sounder is
especially suitable for use in industrial environments with
hazard areas in zone 2 as well as 22. Equipped with an
electronic module for operation directly on a primary control
group of the ¿re alarm panel via a voltage increase.
Product features
Included in delivery
•
•
1 Sounder DS10 MX Ex, ext. tone selection
1 Cable gland M20 x 1.5
1 Blanking plug M20
For use in Ex zones 2 and 22.
Sounder with external tone selection.
Technical specifications
Enclosure material
Not included in delivery
Diecast aluminium, red
IP rating
Ambient temperature
Storage temperature
Relative humidity
IP 67
-25 °C to +55 °C (T4)
-13 °F to +131 °F (T4)
-25 °C to +60 °C (T3)
-13 °F to +140 °F (T3)
-40 °C to +70 °C
-40 °F to +158 °F
max. 90 %
Rated voltage
24 V DC
Operating voltage
19 V - 29 V DC
Rated current consumption
approx. 420 mA
Duty cycle
100 %
Tones
Mounting hardware
Connection / mounting
Recommended cable
2-lead
with function „ext. tone sel.“
3-lead
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Note
The sounder can be operated via the voltage increase
function as well as via the voltage reversal function at the
FMZ 5000 and FMZ 5000 mod S control panels. The device
has an integrated reverse polarity protection diode.
32
Sound pressure
up to 110 dB (A) 1 m
approx. 10000 m2
(107639 square foot),
Ø 116 m (4566 inch)
2200 g (4.9 lbs)
134 x 134 x 143 mm (WxHxD)
5.3 x 5.3 x 5.6 inch (WxHxD)
Sound range
Weight
Dimensions
Approvals / marking
Ex classi¿cation:
P31.320.120 - 2en / 02.14
x II 3G Ex nAc IIC T4 -25°C ” Ta ” +55°C
x II 3G Ex nAc IIC T3 -25°C ” Ta ” +60°C
x II 3D Ex tc IIIB T135°C IP67 -25°C ” Ta ” +60°C
G 204031
0786-CPD-20005
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 15
Product Sheet | Detecon
Means of alarm
Audible Ex
Sounder BExS110E MX
Order no.: 900876
Audible noti¿cation device for signalling ¿re hazards.
The sounder is especially suitable for use in industrial
environments with hazard areas in zone 1. Equipped with an
electronic module for operation directly on a primary control
group of the ¿re alarm panel via a voltage increase.
Product features
Included in delivery
•
1 Sounder BExS110E MX
Explosion-protected device for hazardous zone 1.
•
Sounder with Àameproof enclosure.
•
Terminal compartment compliant with protection rating
"Increased safety Ex e".
Not included in delivery
Mounting hardware
Cable glands
Technical specifications
Enclosure material
Horn material
IP rating
Ambient temperature
Storage temperature
Relative humidity
Rated voltage
ABS, red
IP 67
Ex de IIC T4 (-50 °C to +55 °C)
(-58 °F to +131 °F)
Ex de IIB T4 (-50 °C to +70 °C)
(-58 °F to +158 °F)
-50 °C to +70 °C
(-58 °F to +158 °F)
max. 90 %
Connection / mounting
Recommended cable
Conductor cross-section
2-lead
max. 4 mm2 (0.006 square inch)
Note
The sounder can be operated via the voltage increase
function as well as via the voltage reversal function at the
FMZ 5000 and FMZ 5000 mod S control panels. The device
has an integrated reverse polarity protection diode.
24 V DC
Operating voltage
18 V - 30 V DC
Rated current consumption
approx. 265 mA
Duty cycle
100 %
Tones
32
Sound pressure
Sound range
Weight
Dimensions
P31.320.120 - 1en / 02.14
Diecast aluminium, red
up to 107.5 dB (A) 1 m
approx. 5500 m2
(59201 square foot),
Ø 85 m (3346 inch)
3400 g (7.5 lbs)
181 x 275 mm (dia. x W)
7.1 x 10.8 inch (dia. x W)
Approvals / marking
Ex classi¿cation:
x II 2G Ex de IIC T4
x II 2G Ex de IIB T4
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 16
Product Sheet | Detecon
Means of alarm
Audible Ex
Sounder BExS120E MX
Order no.: 902254
Audible noti¿cation device for signalling ¿re hazards.
The sounder is especially suitable for use in industrial
environments with hazard areas in zone 1. Equipped with an
electronic module for operation directly on a primary control
group of the ¿re alarm panel via a voltage increase.
Product features
Included in delivery
•
Explosion-protected device for hazardous zone 1.
1 Sounder BExS120E MX
•
Sounder with Àameproof enclosure.
•
Terminal compartment compliant with protection rating
"Increased safety Ex e".
Technical specifications
Enclosure material
Horn material
IP rating
Ambient temperature
Storage temperature
Relative humidity
Rated voltage
ABS, red
IP 67
Ex de IIC T4 (-50 °C to +55 °C)
(-58 °F to +131 °F)
Ex de IIB T4 (-50 °C to +70 °C)
(-58 °F to +158 °F)
-50 °C to +70 °C
(-58 °F to +158 °F)
max. 90 %
Recommended cable
Conductor cross-section
2-lead
max. 4 mm2 (0.006 square inch)
Note
The sounder can be operated via the voltage increase
function as well as via the voltage reversal function at the
FMZ 5000 and FMZ 5000 mod S control panels. The device
has an integrated reverse polarity protection diode.
24 V DC
18 V - 30 V DC
Rated current consumption
approx. 900 mA
100 %
Tones
32
Sound pressure
Sound range
Weight
Dimensions
P31.320.120 - 1en / 02.14
Mounting hardware
Cable glands
Connection / mounting
Diecast aluminium, red
Operating voltage
Duty cycle
Not included in delivery
up to115.2 dB (A) 1 m
approx. 30000 m2
(322917 square foot),
Ø 200 m (7874 inch)
3700 g (8.2 lbs)
220 x 326 mm (dia. x W)
8.7 x 12.8 inch (dia. x W)
Approvals / marking
Ex classi¿cation:
x II 2G Ex de IIC T4
x II 2G Ex de IIB T4
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 17
Product Sheet | Detecon
Means of alarm
Audible Ex
Sounder YA90 MX Ex
Order no.: 910654
Audible alarm device for signalling danger of ¿re that is especially suitable for use in industrial environments with hazard
areas in zone 1 as well as 21. Equipped with an electronic
module for operation directly on a primary control group
of the ¿re alarm panel via a voltage increase. The robust
¿breglass-reinforced polyester (FRP) housing is resistant to
environmental effects and chemicals.
Product features
Included in delivery
•
Explosion-proof device for hazardous zone 1 as well
as 21.
•
High volume up to 115 dB (A) / 1 m (39 inch).
1 Sounder YA90 MX Ex
1 Dust cover
1 Blanking plug M20
•
32 standardised tone sequences selectable.
•
2-stage alarm, independently selectable 2nd stage.
•
Tone selection via 5-way DIL switch.
Not included in delivery
Mounting hardwarel
Connection / mounting
Technical specifications
Enclosure material
Horn material
IP rating
Operating temperature
Storing temperature
Relative humidity
Rated voltage
Operating voltage
Rated current consumption
Tones
Fibreglass-reinforced polyester,
red
ABS, red
IP 66
-60 °C to +60 °C
(-76 °F to +140 °F)
-60 °C to +70 °C
(-76 °F to +158 °F)
max. 95 %
Recommended cable
Conductor cross-section
2-lead
max. 2.5 mm2 (0.004 square inch)
Note
The sounder can be operated via the voltage increase function as well as via the voltage reversal function at the FMZ
5000 and FMZ 5000 mod S control panels. The device has
an integrated reverse polarity protection diode.
24 V DC
18 V - 30 V DC
300 mA
32
Sound pressure
Weight
Dimensions
up to 115 dB (A) 1 m
4500 g (9.9 lbs)
210 x 210 x 316 mm (WxHxD)
8.3 x 8.3 x 12.4 inch (WxHxD)
Approvals / marking
P31.320.120 - 3en / 02.14
Ex classi¿cation:
x II 2G Ex d IIC T6 Ta -60°C to +60°C Gb
x II 2D Ex tb IIIC T85°C Ta -60°C to +60°C Db IP66
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 18
Product Sheet | Detecon
Means of alarm
Audible Ex
Sounder YA60 MX Ex
Order no.: 910655
Audible alarm device for signalling danger of ¿re that is especially suitable for use in industrial enviroments with hazard
areas in zone 1 as well as 21. Equipped with an electronic
module for operation directly on a primary control group of
the ¿re alarm panel via a voltage increase. The robust aluminium housing is resistant to sea water, environmental effects
and chemicals.
Product features
Included in delivery
•
Explosion-proof device for hazardous zone 1 as well
as 21.
•
Max. 110 dB (A) / 1 m omnidirectional sound output.
1 Sounder YA60 MX Ex
1 Dust cover
1 blanking plug M20
•
32 standardised tone sequences selectable.
•
2-stage alarm, independently selectable 2nd stage.
•
Tone selection via DIL switch.
Not included in delivery
Mounting hardwarel
Connection / mounting
Technical specifications
Enclosure material
Diecast Aluminium, red
Horn material
Recommended cable
Conductor cross-section
2-lead
max. 2.5 mm2 (0.004 square inch)
ABS, red
IP rating
Operating temperature
Storing temperature
Relative humidity
Rated voltage
IP 66
-35 °C to +60 °C (T4 / T135°C)
(-31 °F to +140 °F (T4 / T135°C))
-35 °C to +40 °C (T6 / T85°C)
(-31 °F to +140 °F (T6 / T85°C))
-35 °C to +60 °C
(-31 °F to +140 °F)
max. 95 %
Note
The sounder can be operated via the voltage increase function as well as via the voltage reversal function at the FMZ
5000 and FMZ 5000 mod S control panels. The device has
an integrated reverse polarity protection diode.
24 V DC
Operating voltage
18 V - 30 V DC
Rated current consumption
Tones
350 mA
32
Sound pressure
up to 110 dB (A) 1 m
Weight
5400 g (11.9 lbs)
288 x 145 mm (HxD)
11.3 x 5.7 inch (HxD)
Dimensions
Approvals / marking
P31.320.120 - 4en / 02.14
Ex classi¿cation:
x II 2G Ex d IIB T4 Ta -35°C to +60°C Gb
x II 2G Ex d IIB T6 Ta -35°C to +40°C Gb
x II 2D Ex tb IIIC T135°C Ta -35°C to +60°C Db IP66
x II 2D Ex tb IIIC T85°C Ta -35°C to +40°C Db IP66
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 19
Product Sheet | Detecon
Means of alarm
Visual
Beacon PY X-S-05-SSM 24 DC red
Order no.: 914142
Visual noti¿cation device in red colour for signalling ¿re
hazards, approved according EN 54-23 and VdS. The
beacon is impressive due to its safe and simple mounting
with external lugs or internal holes, simple electrical
connection on the bottom of the casing. Impact-proof lens.
Equipped with an electronic soft start module for operation
directly on a primary control group of the ¿re alarm panel via
a voltage increase.
Included in delivery
1 Beacon PY X-S-05-SSM 24 DC red
Technical specifications
Dome material
Enclosure material
Approved category
according EN54-23
Flash technology
Flash color
IP rating
PC, red
PC / ABS Blend, red
Xenon
red
Relative humidity
Operating voltage
18 V to 30 V DC
Rated current consumption
Power consumption
Luminous intensity
Flash energy
Flash rate
300 mA
approx. 7.2 W
Dimensions
Connection / mounting
Recommended cable
Conductor cross-section
2-lead
max. 2.5 mm2 (0.004 square inch)
Note
The beacon has three pre-cut cable openings. The device
can be operated via the voltage increase function as well as
via the voltage reversal function at the FMZ 5000 and FMZ
5000 mod S control panels. The device has an integrated
reverse polarity protection diode.
13 cd
5 Joule
1 Hz = 60 Àashes / min.
Weight
Mounting hardware
Cable glands
O
IP 66
-40 °C to +55 °C
(-40 °F to +131 °F)
max. 90 %
Operating temperature
Not included in delivery
200 g (0.44 lbs)
109.5 x 86 x 80.6 mm (WxHxD)
4.31 x 3.39 x 3.17 inch (WxHxD)
Approvals / marking
G 212186
0786-CPD-21219
Design parameters
P31.320.310en / 02.14
See next page
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 20
Product Sheet | Detecon
Means of alarm
Visual
Beacon PY X-S-05-SSM 24 DC red
Design parameters
(optimal mounting alignment)
Category O
O - 4.1 - 2.2 - 3.2 / V = 28.9 m3
Category O is designed as a cuboid.
Design legend:
O
= open mounting position
4.1 = max. edge length in m (Hg)
2.2 = max. edge length in m (Y)
3.2 = max. edge length in m (X)
HM = max. 2.4 m (wall mounting only)
Category W (derived from category O)
W - 2.4 - 2.2 / V = 11.6 m3
Category W is designed as a cube.
Design legend:
W
= wall mounting
2.4 = max. mounting height in m (H)
2.2 = max. cube edge length in m (Y)
P31.320.310en / 02.14
Category C (derived from category O)
C - 3.15 - 3.6 / V = 32 m3
Category C is designed as a cylinder.
Design legend:
C
= ceiling mounting
3.15 = max. mounting height in m (H)
3.6 = max. cylinder diameter in m (Y)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 21
Product Sheet | Detecon
Means of alarm
Visual
Beacon PY X-S-05-SSM 24 DC clear
Art.-Nr.: 914143
Visual noti¿cation device in clear colour for signalling ¿re
hazards, approved according EN 54-23 and VdS. The
beacon is impressive due to its safe and simple mounting
with external lugs or internal holes, simple electrical
connection on the bottom of the casing. Impact-proof lens.
Equipped with an electronic soft start module for operation
directly on a primary control group of the ¿re alarm panel via
a voltage increase.
Included in delivery
1 Beacon PY X-S-05-SSM 24 DC clear
Technical specifications
Dome material
Enclosure material
Approved category
according EN54-23
Flash technology
Flash color
IP rating
PC, clear
PC / ABS Blend, red
Xenon
clear
Relative humidity
Operating voltage
18 V to 30 V DC
Rated current consumption
Power consumption
Luminous intensity
Flash energy
Flash rate
300 mA
approx. 7.2 W
Dimensions
Connection / mounting
Recommended cable
Conductor cross-section
2-lead
max. 2.5 mm2 (0.004 square inch)
Note
The beacon has three pre-cut cable openings. The device
can be operated via the voltage increase function as well as
via the voltage reversal function at the FMZ 5000 and FMZ
5000 mod S control panels. The device has an integrated
reverse polarity protection diode.
55 cd
5 Joule
1 Hz = 60 Àashes / min.
Weight
Mounting hardware
Cable glands
O
IP 66
-40 °C to +55 °C
(-40 °F to +131 °F)
max. 90 %
Operating temperature
Not included in delivery
200 g (0.44 lbs)
109.5 x 86 x 80.6 mm (WxHxD)
4.31 x 3.39 x 3.17 inch (WxHxD)
Approvals / marking
G 212186
0786-CPD-21219
Design parameters
P31.320.310en / 02.14
See next page
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 22
Product Sheet | Detecon
Means of alarm
Visual
Beacon PY X-S-05-SSM 24 DC clear
Design parameters
(optimal mounting alignment)
Category O
O - 11.1 - 8.4 - 6.3 / V = 587.4 m3
Category O is designed as a cuboid.
Design legend:
O
= open mounting position
11.1 = max. edge length in m (Hg)
8.4 = max. edge length in m (Y)
6.3 = max. edge length in m (X)
HM = max. 6.6 m (wall mounting only)
Category W (derived from category O)
W - 5.9 - 7.6 / V = 340 m3
Category W is designed as a cube.
Design legend:
W
= wall mounting
5.9 = max. mounting height in m (H)
7.6 = max. cube edge length in m (Y)
P31.320.310en / 02.14
Category C (derived from category O)
C - 6.8 - 10.6 / V = 600 m3
Category C is designed as a cylinder.
Design legend:
C
= ceiling mounting
6.8 = max. mounting height in m (H)
10.6 = max. cylinder diameter in m (Y)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 23
Product Sheet | Detecon
Means of alarm
Visual
Beacon PY X-S-05-SSM 24 DC yellow
Order no.: 916318
Visual noti¿cation device in yellow colour. The beacon is
impressive due to its safe and simple mounting with external
lugs or internal holes, simple electrical
connection on the bottom of the casing. Impact-proof lens.
Equipped with an electronic soft start module for monitoring
of open and short circuits via the ¿re alarm panel.
Included in delivery
1 Beacon PY X-S-05-SSM 24 DC yellow
Not included in delivery
Technical specifications
Dome material
Enclosure material
PC, yellow
PC / ABS Blend, grey
Flash technology
Xenon
Flash color
yellow
IP rating
Relative humidity
IP 66
-40 °C to +55 °C
(-40 °F to +131 °F)
max. 90 %
Operating voltage
18 V to 30 V DC
Operating temperature
Rated current consumption
Power consumption
Luminous intensity
Flash energy
Flash rate
Mounting hardware
Cable glands
300 mA
approx. 7.2 W
Connection / mounting
Recommended cable
Conductor cross-section
2-lead
max. 2.5 mm2 (0.004 square inch)
Note
The beacon has three pre-cut cable openings. The device
can be operated via the voltage increase function as well as
via the voltage reversal function at the FMZ 5000 and FMZ
5000 mod S control panels. The device has an integrated
reverse polarity protection diode.
51 cd
5 Joule
1 Hz = 60 Àashes / min.
Weight
Dimensions
Approvals / marking
!
Notice
g to EN
cordin
c
a
l
a
v
ro
No app
P31.320.310en / 02.14
applied for
200 g (0.44 lbs)
109.5 x 86 x 80.6 mm (WxHxD)
4.31 x 3.39 x 3.17 inch (WxHxD)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 24
54-23
Product Sheet | Detecon
Means of alarm
Visual
Beacon PY X-S-05-SSM 24 DC blue
Order no.: 916319
Technical specifications
Dome material
PC, blue
Flash color
Otherwise like order no. 916318
blue
Luminous intensity
13 cd
Beacon PY X-S-05-SSM 24 DC green
Order no.: 916320
Technical specifications
Dome material
PC, green
green
Luminous intensity
14 cd
P31.320.310en / 02.14
Flash color
Otherwise like order no. 916318
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 25
Product Sheet | Detecon
Means of alarm
Visual
Beacon L101X red
NEW Order no.: 917444
Optical noti¿cation device for signaling ¿re hazards, approved
according EN 54-23 in categories C and O and VdS. The
beacon can be mounted using external lugs or internal holes.
Included in delivery
1 Beacon L101X red
Not included in delivery
Mounting hardware
Cable glands
Technical specifications
Dome material
Enclosure material
Approved categories
according EN 54-23
Flash technology
Flash color
IP rating
Operating temperature
Storage temperature
Rated voltage
Operating voltage
Rated current consumption
Power consumption
Flash energy
Flash rate
PC, red
ABS, red
2-lead
max. 1.5 mm2 (0.002 square inch)
Xenon
red
IP 66
-25 °C to +55 °C
(-13 °F to +131 °F)
-40 °C to +70 °C
(-40 °F to +158 °F)
24 V DC
20 V to 28 V DC
ca. 275 mA
6W
5 Joule
200 g (0.4 lbs)
114.6 x 86.4 x 83.3 mm (WxHxD)
4.5 x 3.4 x 3.3 inch (WxHxD)
Note
The beacon has two pre-cut M20 cable openings. The device
can only be operated via the voltage reversal function at the
FMZ 5000 and FMZ 5000 mod S control panels. The device
has an integrated reverse polarity protection diode.
Approvals / marking
G 211077
0786-CPD-21247
Note approvals
This beacon cannot be included in the VdS system approval
of the FMZ 5000, due to its technical parameters (minimum
operation voltage)
Design parameters
See next page
P31.320.310en / 02.14
Dimensions
Recommended cable
Conductor cross-section
C, O
1 Hz = 60 Àashes / min.
Weight
Connection / mounting
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 26
Product Sheet | Detecon
Means of alarm
Visual
Beacon L101X red
Design parameters
Category O
O - 1.9 - 3.6 / V = 13.0 m3
Category O is designed as a cuboid.
Design legend:
O
= open mounting position
1.9 = max. edge length in m (Hg and Y)
3.6 = max. edge length in m (X)
P31.320.310en / 02.14
Category C
C - 3 - 2.6 / V = 15.9 m3
Category C is designed as a cylinder.
Design legend:
C
= ceiling mounting
3
= max. mounting height in m (H)
2.6 = max. cylinder diameter in m (Y)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 27
Product Sheet | Detecon
Means of alarm
Visual
Beacon L101X clear
NEW Order no.: 917443
Optical noti¿cation device for signaling ¿re hazards,
approved according EN 54-23 for categories C, W, O and
VdS The beacon can be mounted using external lugs or
internal holes.
Included in delivery
1 Beacon L101X clear
Not included in delivery
Mounting hardware
Cable glands
Technical specifications
Dome material
PC, clear
Connection / mounting
Enclosure material
Approved categories
according EN 54-23
Flash technology
ABS, red
Recommended cable
Conductor cross-section
Flash color
IP rating
Operating temperature
Storage temperature
Rated voltage
C, W, O
Xenon
clear
IP 66
-25 °C to +55 °C
(-13 °F to +131 °F)
-40 °C to +70 °C
(-40 °F to +158 °F)
24 V DC
Operating voltage
20 V to 28 V DC
Rated current consumption
approx. 275 mA
Power consumption
Flash energy
Flash rate
6W
5 Joule
1 Hz = 60 Àashes / min.
Weight
Dimensions
200 g (0.4 lbs)
114.6 x 86.4 x 83.3 mm (WxHxD)
4.5 x 3.4 x 3.3 inch (WxHxD)
2-lead
max. 1.5 mm2 (0.002 square inch)
Note
The beacon has two pre-cut M20 cable openings. The device
can only be operated via the voltage reversal function at the
FMZ 5000 and FMZ 5000 mod S control panels. The device
has an integrated reverse polarity protection diode.
Approvals / marking
G 211077
0786-CPD-21247
Note approvals
This beacon cannot be included in the VdS system approval
of the FMZ 5000, due to its technical parameters (minimum
operation voltage)
Design parameters
P31.320.310en / 02.14
See next page
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 28
Product Sheet | Detecon
Means of alarm
Visual
Beacon L101X clear
Design parameters
Category O
O - 4.8 - 10 / V = 230.4 m3
Category O is designed as a cuboid.
Design legend:
O
= open mounting position
4.8 = max. edge length in m (Hg und Y)
10 = max. edge length in m (X)
Category W
W - 2.4 - 4.8 / V = 55.3 m3
Category W is designed as a cube.
Design legend:
W
= wall mounting
2.4 = max. mounting height in m (H)
4.8 = max. cube edge length in m (Y)
P31.320.310en / 02.14
Category C
C - 9 - 6,8 / V = 326.9 m3
Category C is designed as a cylinder.
Design legend:
C
= ceiling mounting
9
= max. mounting height in m (H)
6,8 = max. cylinder diameter in m (Y)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 29
Product Sheet | Detecon
Means of alarm
Visual
Beacon Solista LX Wall red
NEW Order no.: 917446
Optical noti¿cation device for signaling ¿re hazards, approved
according EN 54-23 for category W. The Àash rate and the
high power or lower power application can be set using the
DIP switches.
Included in delivery
1 Beacon Solista LX Wall red
Not included in delivery
Mounting hardware
Cable glands
Technical specifications
Enclosure material
Approved categories
according EN 54-23
Flash technology
ABS, red
W
LED
Flash color
red
IP rating
IP 65
-25 °C to +70 °C
(-13 °F to +158 °F)
-25 °C to +70 °C
(-13 °F to +158 °F)
24 V DC
Operating temperature
Storage temperature
Rated voltage
Operating voltage
Rated current consumption
at 24 V DC
Surge current
Power consumption
Flash rate adjustable
Weight
Dimensions
9 V to 60 V DC
High Power 1 Hz: 25 mA
High Power 0,5 Hz: 16 mA
Low Power 1 Hz: 16 mA
Low Power 0,5 Hz: 10 mA
< 120 % for 10 ms
Connection / mounting
Recommended cable
Conductor cross-section
2-lead
max. 2.5 mm2 (0.004 square inch)
Note
The beacon has two pre-cut M20 cable openings. The device
can only be operated via the voltage reversal function at the
FMZ 5000 and FMZ 5000 mod S control panels. The device
has an integrated reverse polarity protection diode.
Approvals / marking
applied for
0333-CPD-075441
max. 1,5 W
0.5 Hz = 30 Àashes / min.
1 Hz = 60 Àashes / min.
100 g (0.2 lbs)
93 x 66 mm (DxH)
3.6 x 2.6 inch (DxH)
P31.320.310en / 02.14
Design parameters
Category W
W - 2.4 - 7.5 / V = 135 m3 (high power)
W - 2.4 - 2.5 / V = 15 m3 (low power)
Category W is designed as a cube.
Design legend:
W
= wall mounting
2.4
= max. mounting height in m (H)
7.5/2.5 = max. cube edge length in m (Y)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 30
Product Sheet | Detecon
Means of alarm
Visual
Beacon Solista LX Wall clear
NEW Order no.: 917445
Otherwise like order no. 917446
Technical specifications
clear
P31.320.310en / 02.14
Flash color
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 31
Product Sheet | Detecon
Means of alarm
Visual
Beacon LX Ceiling red
NEW Order no.: 917448
Optical noti¿cation device for signaling ¿re hazards, approved
according EN 54-23 for category C. The Àash rate and the
high power or lower power application can be set using the
DIP switches.
Included in delivery
1 Beacon Solista LX Ceiling red
Not included in delivery
Mounting hardware
Cable glands
Technical specifications
Enclosure material
Approved categories
according EN 54-23
Flash technology
Flash color
IP rating
Operating temperature
Storage temperature
Rated voltage
Operating voltage
Rated current consumption
at 24 V DC
Surge current
Power consumtion
Flash rate adjustable
Weight
Dimensions
ABS, white
C
LED
red
IP 33
IP 65 with extension base (917449)
-25 °C to +70 °C
(-13 °F to +158 °F)
-25 °C to +70 °C
(-13 °F to +158 °F)
24 V DC
9 V to 60 V DC
High Power 1 Hz: 25 mA
High Power 0.5 Hz: 16 mA
Low Power 1 Hz: 16 mA
Low Power 0.5 Hz: 10 mA
< 120 % for 10 ms
Connection / mounting
Recommended cable
Conductor cross-section
2-lead
max. 2.5 mm2 (0.004 square inch)
Note
The device can only be operated via the voltage reversal
function at the FMZ 5000 and FMZ 5000 mod S control panels. The device has an integrated reverse polarity protection
diode. The Extension base Solista Ceiling IP 65 (917449)
must be additionally ordered to increase the IP rating to IP
65.
Approvals / marking
applied for
0333-CPD-075443
max. 1.5 W
0.5 Hz = 30 Àashes / min.
1 Hz = 60 Àashes / min.
100 g (0.2 lbs)
93 x 38 mm (DxH)
3.6 x 2.6 inch (DxH)
P31.320.310en / 02.14
Design parameters
Category C
C - 3 - 7.5 / V = 132 m3 (high power)
C - 3 - 3 / V = 21.2 m3 (low power)
Category C is designed as a cylinder.
Design legend:
C
= ceiling mounting
3
= max. mounting height in m (H)
7.5/3 = max. cylinder diameter in m (Y)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 32
Product Sheet | Detecon
Means of alarm
Visual
Beacon Solista LX Ceiling clear
NEW Order no.: 917447
Otherwise like order no. 917448
Technical specifications
Flash color
clear
Design parameters
P31.320.310en / 02.14
Category C
C - 3 - 7.5 / V = 132 m3 (high power)
C - 3 - 5 / V = 58.9 m3 (low power)
Category C is designed as a cylinder.
Design legend:
C
= ceiling mounting
3
= max. mounting height in m (H)
7.5/5 = max. cylinder diameter in m (Y)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 33
Product Sheet | Detecon
Means of alarm
Visual
Beacon Solex MX
Order no.: 908632
Optical noti¿cation device for signalling ¿re hazards.
Included in delivery
Technical specifications
Dome material
Enclosure material
IP rating
Ambient temperature
Rated voltage
Operating voltage
Rated current consumption
PC, red
ABS, red
IP 65
-25 °C to +70 °C
(-13 °F to +158 °F)
24 V DC
10 V - 60 V DC
100 mA
Power consumption
2.4 W
Luminous intensity
10 cd
Flash rate
1 Beacon Solex MX
Not included in delivery
Mounting hardware
Cable glands
Note
The beacon can only be operated via the voltage reversal
function at the FMZ 5000 and FMZ 5000 mod S control panels. The device has an integrated reverse polarity protection
diode.
1 Hz = 60 Àashes / min.
Weight
Dimensions
180 g (0.4 lbs)
93 x 121 mm (WxH)
3.7 x 4.8 inch (WxH)
Approvals / marking
!
Notice
P31.320.310en / 02.14
alerting
sed for tion or
u
e
b
t
detec
ust no
not
acon m
le in ¿re
This be ation of peop . The device is
u
s
c
a
tem
and ev
ing sys
roved.
tinguish 3 or VdS app
x
e
s
a
g
2
EN 54-
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 34
Product Sheet | Detecon
Means of alarm
Visual
Beacon V4 MX
Order no.: 904207
Visual noti¿cation device for signalling ¿re hazards.
ed
Equipped with an electronic module for operation directly on
a primary control group of the ¿re alarm panel via a voltage
increase.
PC, red
Enclosure material
ABS, red
Flash energy
5 joules
IP 65
-25 °C to +40 °C
(-13 °F to +104 °F)
-40 °C to +70 °C
(-40 °F to +158 °F)
24 V DC
Ambient temperature
Rated voltage
Operating voltage
Luminous intensity
Flash rate
18 V - 30 V DC
250 mA
co
Power consumption
Mounting hardware
Connection / mounting
Recommended cable
Conductor cross-section
n
Storage temperature
Rated current consumption
Not included in delivery
ti
IP rating
1 Beacon V4 MX
n
Dome material
u
Included in delivery
Technical specifications
6W
14 cd
2-lead
max. 2.5 mm2 (0.004 square inch)
Note
The beacon can be operated via the voltage increase function as well as via the voltage reversal function at the
FMZ 5000 and FMZ 5000 mod S control panels. The device
has an integrated reverse polarity protection diode.
1 Hz = 60 Àashes / min.
100 %
is
Duty cycle
Relative humidity
Weight
D
Dimensions
max. 90%
300 g (0.67 lbs)
90 x 90 x 81 mm (WxHxD)
3.5 x 3.5 x 3.2 inch (WxHxD)
Approvals / marking
!
Notice
P31.320.310en / 02.14
54-23
g to EN
in
d
r
o
cc
roval a
No app
al
approv
No VdS
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 35
Product Sheet | Detecon
Means of alarm
Visual
Beacon L101 MX
Order no.: 913433
Visual noti¿cation device for signalling ¿re hazards.
ed
Equipped with an electronic module for operation directly on
a primary control group of the ¿re alarm panel via a voltage
increase.
Technical specifications
Dome material
u
Included in delivery
1 Beacon L101 MX
PC, red
ABS, red
Flash energy
n
Enclosure material
Not included in delivery
5 joules
Ambient temperature
Rated voltage
Operating voltage
Luminous intensity
Flash rate
Recommended cable
Conductor cross-section
275 mA
6.6 W
200 cd
2-lead
max. 1.5 mm2 (0.002 square inch)
Note
20 V - 28 V DC
co
Power consumption
Connection / mounting
n
Storing temperature
Rated current consumption
Mounting hardware
IP 66
-25 °C to +55 °C
(-13 °F to +131 °F)
-40 °C to +70 °C
(-40 °F to +158 °F)
24 V DC
ti
IP rating
The beacon can be operated via the voltage increase function as well as via the voltage reversal function at the
FMZ 5000 and FMZ 5000 mod S control panels. The device
has an integrated reverse polarity protection diode.
1 Hz = 60 Àashes / min.
Dimensions
200 g (0.44 lbs)
90 x 90 x 81 mm (WxHxD)
3.5 x 3.5 x 3.2 inch (WxHxD)
is
Weight
D
Approvals / marking
!
Notice
P31.320.310en / 02.14
54-23
g to EN
in
d
r
o
cc
roval a
No app
al
approv
No VdS
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 36
Product Sheet | Detecon
Means of alarm
Visual
Beacon B300 STR MX
Order no.: 913435
Visual noti¿cation device for signalling ¿re hazards.
ed
Equipped with an electronic module for operation directly on
a primary control group of the ¿re alarm panel via a voltage
increase.
Technical specifications
PC, red
Enclosure material
PC, black
Flash energy
5 joules
IP 65
-25 °C to +50 °C
(-13 °F to +122 °F)
-40 °C to +70 °C
(-40 °F to +158 °F)
24 V DC
Ambient temperature
Rated voltage
Operating voltage
Flash rate
20 V - 28 V DC
275 mA
co
Power consumption
6.6 W
1 Hz = 60 Àashes / min.
Relative humidity
Dimensions
375 g (0.83 lbs)
100 x 150 mm (DxH)
3.5 x 3.5 x 3.2 inch (DxH)
D
Approvals / marking
Wall bracket flasher B300 STR MX
P31.320.310en / 02.14
Connection / mounting
Recommended cable
Conductor cross-section
2-lead
max. 1.5 mm2 (0.002 square inch)
Note
The beacon can be operated via the voltage increase function as well as via the voltage reversal function at the
FMZ 5000 and FMZ 5000 mod S control panels. The device
has an integrated reverse polarity protection diode.
max. 90 %
is
Weight
Mounting hardware
n
Storing temperature
Rated current consumption
Not included in delivery
ti
IP rating
1 Beacon B300 STR MX
n
Dome material
u
Included in delivery
!
Notice
g to EN
cordin
c
a
l
a
v
ro
No app
al
approv
No VdS
54-23
Order no.: 913440
Elements for mounting the B300 STR MX Àashing light
against the wall.
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 37
Product Sheet | Detecon
Means of alarm
Visual
Rotating beacon R401-61 red
NEW Order no.: 917450
Optical noti¿cation device for signaling ¿re hazards.
360° rotating beacon with parabola reÀector. The connection
cable can be inserted via an M20 cable opening or through
the base of the rotating beacon.
Included in delivery
Technical specifications
Dome material
PC, red
Base material
IP rating
Operating temperature
Storage temperature
Rated voltage
ABS, black
IP 65
-10 °C to +55 °C
(14 °F to +131 °F)
-10 °C to +55 °C
(14 °F to +131 °F)
24 V DC
Operating voltage
20 V - 28 V DC
Rated current consumption
0.95 A
Power consumption
Weight
Dimensions
1 Rotating beacon R401-61 red
1 Foam rubber disk
21 W
980 g (2.2 lbs)
150 x 205 mm (DxH)
5.9 x 8.1 inch (DxH)
Not included in delivery
Mounting hardware
Cable glands
Connection / mounting
Recommended cable
Conducter cross-section
2-lead
max. 2.5 mm2 (0.004 square inch)
Note
The rotating beacon has a pre-cut M20 cable opening. The
device can only be triggered via relay contacts.
Approvals / marking
Rotating beacon R401-61 amber
NEW Order no.: 917451
P31.320.310en / 02.14
Otherwise like order no. 917450
Technical specifications
Dome material
PC, amber
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 38
Product Sheet | Detecon
Means of alarm
Visual, addressable
Loop Beacon LBX 877r
Order no.: 905820
Loop Beacon for optical signalling in red. The beacon can be
¿tted to any Loop AP detector base. Addressing is done via
an integrated address card.
Included in delivery
ed
1 Loop Beacon LBX 877r
Not included in delivery
Mounting hardware
Detector base for Loop AP
PC
IP rating
IP 23D
Technology / protocol
Loop AP / XP95
Enclosure colour
white
red
Integrated isolator
no
-20 °C to +60 °C
(-4 °F to +140 °F)
17 V - 28 V DC
n
Operating temperature
Operating voltage
Operating current siren
Relative humidity
Weight
is
Dimensions
3 mA
150 —A
0 - 95 %
no condensation
140 g (0.30 lbs)
115 x 38 mm (DxH)
4.52 x 1.49 inch (DxH)
co
Rated current consumption
!
Notice
g to EN
cordin
c
a
l
a
v
ro
No app
al
approv
No VdS
P31.320.310 - 6en / 02.14
D
Approvals / marking
Cable recommendation standard
J-Y(St)Y -2x2x0.8 mm, red
747180
Recommended cable
2-lead
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Electrostatic shielding
Not required
ti
Spherical cup colour
Connection / mounting
u
Enclosure material
n
Technical specifications
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 39
54-23
Product Sheet | Detecon
Means of alarm
Visual, addressable
Loop Beacon LBX 878k
Order no.: 912571
Loop Beacon for optical signalling in clear glass. The beacon
can be ¿tted to any Loop AP detector base. Addressing is
done via an integrated address card.
Included in delivery
ed
1 Loop Beacon LBX 878k
Not included in delivery
Enclosure material
PC
IP rating
IP 23D
Technology / protocol
Loop AP / XP95
white
Spherical cup colour
clear
Integrated isolator
no
-20 °C to +60 °C
(-4 °F to +140 °F)
17 V - 28 V DC
n
Operating temperature
Operating voltage
Operating current siren
Relative humidity
Weight
150 —A
0 - 95 %
no condensation
140 g (0.30 lbs)
115 x 38 mm (DxH)
4.52 x 1.49 inch (DxH)
is
Dimensions
3 mA
co
Rated current consumption
!
Notice
EN
ing to
accord
l
a
v
o
r
No app
al
approv
No VdS
P31.320.310 - 6en / 02.14
D
Approvals / marking
Cable recommendation standard
J-Y(St)Y -2x2x0.8 mm, red
747180
Recommended cable
2-lead
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Electrostatic shielding
Not required
ti
Enclosure colour
Connection / mounting
n
Technical specifications
u
Mounting hardware
Detector base for Loop AP
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 40
54-23
Product Sheet | Detecon
Means of alarm
Visual, addressable
Loop Beacon LBX 009r WP
Order no.: 912569
Loop beacon for the LoopAP for optical signalling with integrated dual isolator in red. Addressing is done via integrated
DIP switches.
Included in delivery
ed
1 Loop Beacon LBX 009r WP
Not included in delivery
Mounting hardware
Technical specifications
PC
IP rating
IP 65
Technology / protocol
Loop AP / XP95
red
Spherical cup colour
red
ti
Enclosure colour
Integrated isolator
yes
-10 °C to +55 °C
(-14 °F to +131 °F)
17 V - 28 V DC
n
Operating temperature
Operating voltage
Operating current siren
Weight
3.1 mA
330 —A
co
Rated current consumption
205 g (0.45 lbs)
104 x 97.5 mm (DxH)
4.09 x 3.83 inch (DxH)
Dimensions
!
Notice
g to EN
ccordin
a
l
a
v
o
r
No app
al
approv
No VdS
P31.320.310 - 6en / 02.14
D
is
Approvals / marking
Cable recommendation standard
J-Y(St)Y -2x2x0.8 mm, red
747180
Recommended cable
2-lead
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Electrostatic shielding
Not required
n
Enclosure material
u
Connection / mounting
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 41
54-23
Product Sheet | Detecon
Means of alarm
Visual, addressable
Loop Beacon LBX 010k WP
Order no.: 912582
Loop beacon for the LoopAP for optical signalling with
integrated dual isolator in clear glass. Addressing is done via
integrated DIP switches.
Included in delivery
ed
1 Loop Beacon LBX 010k WP
Not included in delivery
Mounting hardware
Technical specifications
PC
IP rating
IP 65
Technology / protocol
Loop AP / XP95
white
Spherical cup colour
clear
ti
Enclosure colour
Integrated isolator
yes
-10 °C to +55 °C
(-14 °F to +131 °F)
17 V - 28 V DC
n
Operating temperature
Operating voltage
Operating current siren
Weight
3.1 mA
330 —A
co
Rated current consumption
205 g (0.45 lbs)
104 x 97.5 mm (DxH)
4.09 x 3.83 inch (DxH)
Dimensions
!
Notice
g to EN
cordin
c
a
l
a
v
ro
No app
al
approv
No VdS
P31.320.310 - 6en / 02.14
D
is
Approvals / marking
Cable recommendation standard
J-Y(St)Y -2x2x0.8 mm, red
747180
Recommended cable
2-lead
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Electrostatic shielding
Not required
n
Enclosure material
u
Connection / mounting
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 42
54-23
Product Sheet | Detecon
Means of alarm
Visual, Ex
Beacon Quadro-LED Flex-3GD-MX
Order no.: 908035
Visual noti¿cation device for signalling ¿re hazards in
potentially explosive atmospheres in zone 2 and 22.
Fitted with an electronic module for operation directly on a
primary control group of the ¿re alarm panel via a voltage
increase.
Product features
Included in delivery
•
•
1 Beacon Quadro-LED Flex-3GD-MX.
•
Explosion-protected equipment.
Choice of operating modes for 4 different alarm signals:
steady light, Àashing light, strobe light and rotating light.
Applications: industrial presses.
Not included in delivery
Mounting hardware
Connection / mounting
Technical specifications
Dome material
Enclosure material
Light source
Ambient temperatures
Relative humidity
PC, red
PC, grey
16 LEDs
-20 °C to +50 °C (T6)
-4 °F to +122 °F (T6)
-20 °C to +55 °C (T5)
-4 °F to +131 °F (T5)
max. 90 %
Rated voltage
24 V DC
Flashing light
1 Hz = 60 Àashes / min.
Strobe light
Rotating light
1.5 Hz = 90 Àashes / min.
2.5 Hz = 150 Àashes / min.
Operating voltage
15 V - 30 V DC
Rated current consumption
approx. 300 mA
Power consumption
Luminous intensity
IP rating (EN 60529)
Service life of beacon
Duty cycle
Recommended cable
2-lead
Conductor cross-section:
0.2 mm2 to 6 mm2
(0.0003 square inch to 0.009 square inch)
Note
The beacon can be operated via the voltage increase
function as well as via the voltage reversal function at the
FMZ 5000 and FMZ 5000 mod S control panels. The device
has an integrated reverse polarity protection diode.
Approvals / marking
Ex classi¿cation:
x II 3G Ex nRc IIC T6 -20°C ” Ta ” +50°C
x II 3G Ex nRc IIC T5 -20°C ” Ta ” +55°C
x II 3D Ex tc IIIB T90°C IP66 -20°C ” TA ” +55°C
7.2 W
6.1 cd with steady light
IP 66
> 50000 hrs
100 %
Weight
P31.320.320en / 02.14
Dimensions
500 g (1.1 lbs)
130 x 130 x 130 mm (WxHxD)
5.1 x 5.1 x 5.1 inch (WxHxD)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 43
Product Sheet | Detecon
Means of alarm
Visual, Ex
Beacon CWB-ATEX-MX Ex
Order no.: 903761
Visual noti¿cation device for signalling ¿re hazards in
potentially explosive atmospheres in zone 1 as well as zones
21. Fitted with an electronic module for monitoring directly on
a primary control group of the ¿re alarm panel via a voltage
increase.
Product features
Included in delivery
•
•
•
1 Beacon CWB-ATEX-MX Ex complete with mounting
bracket.
Explosion-protected equipment.
Aluminium enclosure.
Applications: chemical and petrochemical facilities and
offshore facilities.
Not included in delivery
Mounting hardware
Technical specifications
Dome material
Enclosure material
Flash energy
Ambient temperatures
Storage temperature
Relative humidity
Rated voltage
Operating voltage
Rated current consumption
Power consumption
Luminous intensity
IP rating (EN 60529)
Flash rate
Connection / mounting
PC, red
Aluminium alloy, yellow/black
5 joules
-40 °C to +40 °C (T6 / T85°C)
(-40 °F to +104 °F (T6 / T85°C))
-40 °C to +50 °C (T5 / T100°C)
(-40 °F to +122 °F (T5 / T100°C))
-40 °C to +80 °C
(-40 °F to +140 °F)
max. 90 %
24 V DC
18 V - 30 V DC
400 mA
9.6 W
9 cd
IP 66
Recommended cable
2-lead
Conductor cross-section:
- power supply
max. 2.5 mm2 (0.004 square inch)
- protective earth terminal
outside max. 6 mm2 (0.009 square inch)
inside max. 2.5 mm2 ( 0.004 square inch)
Note
The beacon can be operated via the voltage increase
function as well as via the voltage reversal function at the
FMZ 5000 and FMZ 5000 mod S control panels. The device
has an integrated reverse polarity protection diode.
Approvals / marking
Ex classi¿cation:
x II 2G Ex de IIC T6/T5 Gb
x II 2D Ex tb IIIC T85°C/T100°C Db IP66
1 Hz = 60 Àashes / min.
Service life of beacon
Duty cycle
approx. 5800 hrs
100 %
Weight
P31.320.320en / 02.14
Dimensions
1240 g (7.73 lbs)
70 x 260 mm (dia. x H)
2.8 x 10.2 inch (dia. x H)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 44
Product Sheet | Detecon
Means of alarm
Visual, Ex
Beacon CWB-ATEX-MX Ex
Order no.: 905344
Technical specifications
Dome material
PC, yellow
Beacon CWB-ATEX-MX Ex
Otherwise like order no. 903761
Order no.: 905343
Technical specifications
PC, blue
Otherwise like order no. 903761
P31.320.320en / 02.14
Dome material
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 45
Product Sheet | Detecon
Means of alarm
Visual, Ex
Beacon FL60 MX Ex
Order no.: 910656
Optical alarm device for signalling danger of ¿re that is especially suitable for use in industrial environments with hazard
areas in zone 1 as well as 21. Equipped with an electronic
module for operation directly on a primary control group of
the ¿re alarm panel via a voltage increase. The robust aluminium housing is resistant to sea water, environmental effects
and chemicals.
Product features
Included in delivery
•
Explosion-proof device for
hazardous zone 1 as well as 21.
1 Beacon FL60 MX Ex
1 Blanking plug
•
Fitted as standard with protective cage.
Not included in delivery
Mounting hardware
Technical specifications
Horn material
Enclosure material
Operating temperature
Storage temperature
Relative humidity
Rated voltage
Flash rate
PC, red
Diecast Aluminium, red
-35 °C to +60 °C (T4 / T135°C)
(-31 °F to +140 °F (T4 / T135°F))
-35 °C to +40 °C (T6 / T85°C)
(-31 °F to +104 °F (T6 / T85°F))
-35 °C to +60 °C)
(-31 °F to +140 °F)
max. 95 %
24 V DC
1 Hz = 60 Àashes / min.
Flash energy
5J
Operating voltage
18 V - 30 V DC
Rated current consumption
approx. 220 mA
Power consumption
Luminous itensity
IP rating (EN 60529)
Weight
Recommended cable
Conductor cross-section:
2-lead
2.5 mm2 (0.004 square inch)
Note
The beacon can be operated via the voltage increase function as well as via the voltage reversal function at the FMZ
5000 and FMZ 5000 mod S control panels. The device has
an integrated reverse polarity protection diode.
Approvals / marking
Ex classi¿cation:
x II 2G Ex d IIB T4 Ta -35°C to +60°C Gb
x II 2G Ex d IIB T6 Ta -35°C to +40°C Gb
x II 2D Ex tb IIIC T135°C Ta -35°C to +60°C Db IP66
x II 2D Ex tb IIIC T85°C Ta -35°C to +40°C Db IP66
IP 66
5080 g (11.2 lbs)
276 x 145 mm (HxT)
10.9 x 5.7 inch (HxT)
P31.320.320en / 02.14
Dimensions
5.3 W
6.1 cd with continous light
Connection / mounting
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 46
Product Sheet | Detecon
Means of alarm
Visual, Ex
Beacon BExBG05E MX Ex
Order no.: 913425
Optical alarm device for signalling danger of ¿re that is especially suitable for use in industrial environments with hazard
areas in zone 1 as well as 21. Equipped with electronic module for operation directly on a primary control group of the
¿re alarm panel via a voltage increase. The robust aluminium
housing is resistant to sea water, environmental effects and
chemicals.
Product features
Included in delivery
•
Explosion-proof equipment for
Ex zone 1 as well as 21.
1 Beacon BExBG05E MX Ex with mounting bracket
•
Fitted as standard with protective cage.
Not included in delivery
Mounting hardware
Technical specifications
Connection / mounting
Spherical calotte material
Borosilicate glass, red
Enclosure material
Aluminium, red
-50 °C to +70 °C (T4)
-58 °F to +158 °F (T4)
-50 °C to +55 °C (T5)
-58 °F to +131 °F (T5)
-50 °C to +40 °C (T6)
-58 °F to +104 °F (T6)
24 V DC
Operating temperature 2G
Rated voltage
Flash rate
1 Hz = 60 Àashes / min.
Flash energy
Recommended cable
2-lead
Conductor cross-section:
0.5 mm2 to 4 mm2
(0.0007 square inch to 0.006 square inch)
Note
The beacon can be operated via the voltage increase function as well as via the voltage reversal function at the FMZ
5000 and FMZ 5000 mod S control panels. The device has
an integrated reverse polarity protection diode.
5J
Operating voltage
20 V - 28 V DC
Approvals / marking
Rated current consumption
approx. 300 mA
Ex classi¿cation:
Power consumption
7.2 W
IP rating (EN 60529)
IP 66
Weight
P31.320.320en / 02.14
Dimensions
2450 g (5.4 lbs)
295 x 154 mm (HxD)
11.61 x 6.06 inch (HxD)
(without mounting bracket)
x II 2G Ex de IIC T4 Ta.-50°C to +70°C
x II 2G Ex de IIC T5 Ta.-50°C to +55°C
x II 2G Ex de IIC T6 Ta.-50°C to +40°C
x II 2D tD A21 IP66 T115°C
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 47
Product Sheet | Detecon
Means of alarm
Audible / visual
Sounder / Beacon PA X-1-05-SSM 24 DC
red
Order no.: 914144
Audible/visual noti¿cation device in red colour for signalling
¿re hazards, approved according EN 54-3, EN 54-23 and
VdS. The sounder/beacon is impressive due to its safe and
simple mounting with external lugs or internal holes, simple
electrical connection on the bottom of the casing. The
sounder/beacon is impact-proof.
Equipped with an electronic soft start module for operation
directly on a primary control group of the ¿re alarm panel via
a voltage increase.
Included in delivery
Technical specifications
Dome material
Enclosure material
Approved categories
according EN54-23
Flash technology
Flash color
IP rating
Operating temperature
Relative humidity
Operating voltage
Rated current consumption:
Beacon
Sounder
Power consumption
Luminous intensity
Flash energy
Flash rate
PC, red
PC / ABS Blend, red
O
Xenon
red
IP 66
-40 °C to +55 °C
(-40 °F to +131 °F)
approx. 90 %
18 V - 30 V DC
300 mA
38 mA (at 24 V / DIN-Ton)
approx. 8.1 W
13 cd
5 Joule
1 Hz = 60 Àashes / min.
Tones
80
Tone stages
Sound pressure
Weight
Not included in delivery
Mounting hardware
Cable glands
Connection / mounting
Recommended cable
Conductor cross-section
2-lead
max. 2.5 mm2 (0.004 square inch)
Note
The combination unit has three pre-cut cable openings. The
device can be operated via the voltage increase function as
well as via the voltage reversal function at the FMZ 5000
and FMZ 5000 mod S control panels. The device has an
integrated reverse polarity protection diode.
Approvals / marking
G 212188
0786-CPD-21220
3 additional externally selectable
up to 105 dB (A) / 1 m
560 g (1.23 lbs)
109.5 x 172.4 x 80.6 mm (WxHxD)
4.31 x 6.79 x 3.17 inch (WxHxD)
Beacon design parameters
See next page
P31.320.510 - 1en / 02.14
Dimensions
1 Sounder / Beacon PA X-1-05-SSM 24 DC red
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 48
Product Sheet | Detecon
Means of alarm
Audible / visual
Sounder / Beacon PA X-1-05-SSM 24 DC
red
Beacon design parameters
(optimal mounting alignment)
Category O
O - 4.1 - 2.2 - 3.2 / V = 28.9 m3
Category O is designed as a cuboid.
Design legend:
O
= open mounting position
4.1 = max. edge length in m (Hg)
2.2 = max. edge length in m (Y)
3.2 = max. edge length in m (X)
HM = max. 2.4 m (wall mounting only)
Category W (derived from category O)
W - 2.4 - 2.2 / V = 11.6 m3
Category W is designed as a cube.
Design legend:
W
= wall mounting
2.4 = max. mounting height in m (H)
2.2 = max. cube edge length in m (Y)
P31.320.510 - 1en / 02.14
Category C (derived from category O)
C - 3.15 - 3.6 / V = 32 m3
Category C is designed as a cylinder.
Design legend:
C
= ceiling mounting
3.15 = max. mounting height in m (H)
3.6 = max. cylinder diameter in m (Y)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 49
Product Sheet | Detecon
Means of alarm
Audible / visual
Sounder / Beacon PA X-1-05-SSM 24 DC
clear
Order no.: 914145
Audible/visual noti¿cation device in clear colour for signalling
¿re hazards, approved according EN 54-3, EN 54-23 and
VdS. The sounder/beacon is impressive due to its safe and
simple mounting with external lugs or internal holes, simple
electrical connection on the bottom of the casing. The
sounder/beacon is impact-proof.
Equipped with an electronic soft start module for operation
directly on a primary control group of the ¿re alarm panel via
a voltage increase.
Included in delivery
Technical specifications
Dome material
Enclosure material
Approved categories
according EN54-23
Flash technology
Flash color
IP rating
Operating temperature
Relative humidity
Operating voltage
Rated current consumption:
Beacon
Sounder
Power consumption
Luminous intensity
Flash energy
Flash rate
PC, clear
PC / ABS Blend, red
O
Xenon
clear
IP 66
-40 °C to +55 °C
(-40 °F to +131 °F)
approx. 90 %
18 V - 30 V DC
300 mA
38 mA (at 24 V / DIN-Ton)
approx. 8.1 W
55 cd
5 Joule
1 Hz = 60 Àashes / min.
Tones
80
Tone stages
Sound pressure
Weight
Not included in delivery
Mounting hardware
Cable glands
Connection / mounting
Recommended cable
Conductor cross-section
2-lead
max. 2.5 mm2 (0.004 square inch)
Note
The combination unit has three pre-cut cable openings. The
device can be operated via the voltage increase function as
well as via the voltage reversal function at the FMZ 5000
and FMZ 5000 mod S control panels. The device has an
integrated reverse polarity protection diode.
Approvals / marking
G 212188
0786-CPD-21220
3 additional externally selectable
up to 105 dB (A) / 1 m
560 g (1.23 lbs)
109.5 x 172.4 x 80.6 mm (WxHxD)
4.31 x 6.79 x 3.17 inch (WxHxD)
Beacon design parameters
See next page
P31.320.510 - 1en / 02.14
Dimensions
1 Sounder / Beacon PA X-1-05-SSM 24 DC clear
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 50
Product Sheet | Detecon
Means of alarm
Audible / visual
Sounder / Beacon PA X-1-05-SSM 24 DC
clear
Beacon design parameters
(optimal mounting alignment)
Category O
O - 11.1 - 8.4 - 6.3 / V = 587.4 m3
Category O is designed as a cuboid.
Design legend:
O
= open mounting position
11,1 = max. edge length in m (Hg)
8,4 = max. edge length in m (Y)
6,3 = max. edge length in m (X)
HM = max. 6.6 m (wall mounting only)
Category W (derived from category O)
W - 5.9 - 7.6 / V = 340 m3
Category W is designed as a cube.
Design legend:
W
= wall mounting
5.9 = max. mounting height in m (H)
7.6 = max. cube edge length in m (Y)
P31.320.510 - 1en / 02.14
Category C (derived from category O)
C - 6.8 - 10.6 / V = 600 m3
Category C is designed as a cylinder.
Design legend:
C
= ceiling mounting
6.8 = max. mounting height in m (H)
10.6 = max. cylinder diameter in m (Y)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 51
Product Sheet | Detecon
Means of alarm
Audible / visual
Sounder / Beacon SONFL1X red
NEW Order no.: 917453
Optical and audible noti¿cation device for signaling ¿re hazards, in approval for EN 54-3 and EN 54-23 for categories C
and O and VdS. The combination unit can be mounted using
external lugs or internal holes.
Included in delivery
Technical specifications
Dome material
Enclosure material
Approved categories
according EN 54-23
Flash technology
Flash color
Flash energy
IP rating
Operating temperature
Storage temperature
Rated voltage
PC, red
ABS, red
C, O
Xenon
red
5 Joule
IP 66
-25 °C to +55 °C
(-13 °F to +131 °F)
-40 °C to +70 °C
(-40 °F to +158 °F)
24 V DC
Operating temperature
20 V - 28 V DC
Rated current consumption
approx. 340 mA
Power consumption
8W
Flash rate
1 Hz = 60 Àashes / min.
Duty cycle
100 %
Tones
1 Sounder / Beacon SONFL1X red
Not included in delivery
Mounting hardware
Cable glands
Connection / mounting
Recommended cable
Conductor cross-section
2-leads
1.5 mm2 (0.002 square inch)
Note
The device has three pre-cut M20 cable openings. The
device can only be operated via the voltage reversal function
at the FMZ 5000 and FMZ 5000 mod S control panels. The
device has an integrated reverse polarity protection diode.
Approvals / marking
applied for
applied for
10
Sound pressure
Relative humidity
Weight
Dimensions
to 100 dB (A) 1 m
max. 90% at 20 °C (68 °F)
500 g (1.1 lbs)
114.6 x 172 x 84 mm (WxHxD)
4.5 x 6.8 x 3.3 inch (WxHxD)
Note approvals
This Sounder / beacon cannot be included in the VdS system
approval of the FMZ 5000, due to its technical parameters
(minimum operation voltage)
Beacon design parameters
P31.320.510 - 1en / 02.14
See next page
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 52
Product Sheet | Detecon
Means of alarm
Audible / visual
Sounder / Beacon SONFL1X red
Beacon design parameters
Category O
O - 1.9 - 3.6 / V = 13 m3
Category O is designed as a cuboid.
Design legend:
O
= open mounting position
1.9 = max. edge length in m (Hg und Y)
3.6 = max. edge length in m (X)
HM = max. 2.4 m (wall mounting only)
P31.320.510 - 1en / 02.14
Category C
C - 3 - 2.6 / V = 15.9 m3
Category C is designed as a cylinder.
Design legend:
C
= ceiling mounting
3
= max. mounting height in m (H)
2.6 = max. cylinder diameter in m (Y)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 53
Product Sheet | Detecon
Means of alarm
Audible / visual
Sounder / Beacon SONFL1X clear
NEW Order no.: 917452
Optical and audible noti¿cation device for signaling ¿re
hazards, in approved for EN 54-3 and EN 54-23 for categories C, W, O and VdS. The combination unit can be mounted
using external lugs or internal holes.
Included in delivery
Technical specifications
Dome material
PC, clear
Enclosure material
Approved categories
according EN 54-23
Flash technology
ABS, red
Flash color
Flash energy
IP rating
Operating temperature
Storage temperature
Rated voltage
C, W, O
Xenon
clear
5 Joule
IP 66
-25 °C to +55 °C
(-13 °F to +132 °F)
-40 °C to +70 °C
(-40 °F to +158 °F)
24 V DC
Operating voltage
20 V - 28 V DC
Rated curren consumption
approx. 340 mA
Power consumption
8W
Flash rate
1 Hz = 60 Àashes / min.
Duty cycle
100 %
Tones
1 Sounder / Beacon SONFL1X clear
Not included in delivery
Mounting hardware
Cable glands
Connection / mounting
Recommended cable
Conductor cross-section
2-leads
1.5 mm2 (0.002 square inch)
Note
The device has three pre-cut M20 cable openings. The
device can only be operated via the voltage reversal function
at the FMZ 5000 and FMZ 5000 mod S control panels. The
device has an integrated reverse polarity protection diode.
Approvals / marking
applied for
applied for
10
Sound pressure
Relative humidity
Weight
Dimensions
to 100 dB (A) 1 m
max. 90% at 20 °C (68 °F)
500 g (1.1 lbs)
114.6 x 172 x 84 mm (WxHxD)
4.5 x 6.8 x 3.3 inch (WxHxD)
Note approvals
This Sounder / beacon cannot be included in the VdS system
approval of the FMZ 5000, due to its technical parameters
(minimum operation voltage)
Beacon design parameters
P31.320.510 - 1en / 02.14
See next page
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 54
Product Sheet | Detecon
Means of alarm
Audible / visual
Sounder / Beacon SONFL1X clear
Beacon design parameters
Category O
O - 4.8 - 10 / V = 230.4 m3
Category O is designed as a cuboid.
Design legend:
O
= open mounting position
4.8 = max. edge length in m (Hg und Y)
10 = max. edge length in m (X)
HM = max. 2.4 m (wall mounting only)
Category W
W - 2.4 - 4.8 / V = 55.3 m3
Category W is designed as a cube.
Design legend:
W
= wall mounting
2.4 = max. mounting height in m (H)
4.8 = max. cube edge length in m (Y)
P31.320.510 - 1en / 02.14
Category C
C - 9 - 6.8 / V = 326.9 m3
Category C is designed as a cylinde.
Design legend:
C
= ceiling mounting
9
= max. mounting height in m (H)
6.8 = max. cylinder diameter in m (Y)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 55
Product Sheet | Detecon
Means of alarm
Audible / visual
Sounder / Beacon ROLP LX Wall red
NEW Order no.: 917455
Optical and audible noti¿cation device for signaling ¿re
hazards, approved according EN 54-3 and EN 54-23 for category W. The Àash rate and the high power or lower power
application can be set using the DIP switch. The sounder
volume is also set via the DIP switch.
Included in delivery
Technical specifications
Enclosure material
Approved categories
according EN 54-23
Flash technology
ABS, red
W
LED
Flash color
red
IP rating
IP 65
-25 °C to +70 °C
(-13 °F to +158 °F)
-25 °C to +70 °C
(-13 °F to +158 °F)
24 V DC
Operating temperature
Store temperature
Raed voltage
Operating voltage
Raed current consumption
at 24 V DC
Surge current
Flash sequence adjustable
Tones
Sound pressure
Weight
Dimensions
9 V - 60 V DC
High Power 1 Hz: 55 mA
High Power 0.5 Hz: 46 mA
Low Power 1 Hz: 46 mA
Low Power 0.5 Hz: 40 mA
< 120 % for 10 ms
0.5 Hz = 30 Àashes / min.
1 Hz = 60 Àashes / min.
32
up to 102 dB (A) 1 m
1 Sounder / Beacon ROLP LX Wall red
Not included in delivery
Mounting hardware
Cable glands
Connection / mounting
Recommended cable
Conductor cross-section
2-leads
2.5 mm2 (0.004 square inch)
Note
The device has two pre-cut M20 cable openings. The device
can only be operated via the voltage reversal function at the
FMZ 5000 and FMZ 5000 mod S control panels. The device
has an integrated reverse polarity protection diode.
Approvals / marking
applied for
0333-CPR-075444
200 g (0.4 lbs)
135 x 95 x 95 mm (BxHxT)
5.3 x 3.7 x 3.7 inch (WxHxD)
P31.320.510 - 1en / 02.14
Design parameters
Category W
W - 2.4 - 7.5 / V = 135 m3 (high power)
W - 2.4 - 2.5 / V = 15 m3 (low power)
Category W is designed as a cube.
Design legend:
W
= wall mounting
2.4
= max. mounting height in m (H)
2.5/7.5 = max. cube edge length in m (Y)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 56
Product Sheet | Detecon
Means of alarm
Audible / visual
Sounder / Beacon ROLP LX Wall clear
NEW Order no.: 917454
Otherwise like order no. 917455
Technical specifications
clear
P31.320.510 - 1en / 02.14
Flash color
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 57
Product Sheet | Detecon
Means of alarm
Audible / visual
Sounder / Beacon Flashni MX
Order no.: 908633
u
ed
Audible and visual noti¿cation device for signalling ¿re
hazards. The alarm signalling device offers a selection of
32 acoustic signals and the con¿guration is carried out via a
¿ve -pin DIP switch. Up to two different acoustic signals can
be con¿gured via wiring. The volume of the signal can be
adjusted as well. Alarm sounder and Àashing light may be
activated separately.
Included in delivery
Dome material
PC, red
Enclosure material
ABS, red
Flash energy
0.7 joules
Not included in delivery
Mounting hardware
IP 65
ti
IP rating
1 Sounder / Beacon Flashni MX
n
Technical specifications
Rated voltage
24 V DC
18 V - 30 V DC
Rated current consumption
approx. 92 mA
Power consumption
Flash rate
The combination unit can only be operated via the voltage
reversal function at the FMZ 5000 and FMZ 5000 mod S
control panels. The device has an integrated reverse polarity
protection diode.
2.2 W
10 cd
co
Luminous intensity
Note
n
Operating voltage
1 Hz = 60 Àashes / min.
Tones
32
Sound pressure
Weight
Dimensions
is
Ambient temperature
!
Notice
g to EN
cordin
c
a
l
a
v
ro
No app pproval
a
S
d
V
No
P31.320.510 - 1en / 02.14
D
Approvals / marking
up to 101 dB (A) 1 m
-10 °C to +55 °C
(+14 °F to +131 °F)
330 g (0.73 lbs)
93 x 121 mm (WxH)
3.7 x 4.8 inch (WxH)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 58
54-23
Product Sheet | Detecon
Means of alarm
Audible / visual
Sounder / Beacon SONFL 1 MX
Order no.: 906508
ed
Audible and visual noti¿cation device for signalling ¿re
hazards. Equipped with an electronic module for operation
directly on a primary control group of the ¿re alarm panel via
a voltage increase.
PC, red
Enclosure material
ABS, red
Flash energy
5 joules
IP 66
-25 °C to +55 °C
(-13 °F to +131 °F)
-40 °C to +70 °C
(-40 °F to +158 °F)
24 V DC
Not included in delivery
Mounting hardware
ti
IP rating
1 Sonder / Beacon SONFL 1 MX
n
Dome material
u
Included in delivery
Technical specifications
Ambient temperature
The combination unit can be operated via the voltage increase function as well as via the voltage reversal function at the
FMZ 5000 and FMZ 5000 mod S control panels. The device
has an integrated reverse polarity protection diode.
n
Storage temperature
Note
Rated voltage
20 V - 29 V DC
Rated current consumption
approx. 340 mA
Power consumption
Luminous intensity
Flash rate
co
Operating voltage
6.6 W
150 cd
1 Hz = 60 Àashes / min.
100 %
Tones
Sound pressure
is
Duty cycle
Service life of beacon
D
Relative humidity
Sound range
Weight
Dimensions
10
up to 100 dB (A) 1 m
approx. 4400 hrs
max. 90%
approx. 1300 m2
(13993 square foot),
Ø 40 m (1575 inch)
460 g (1.1 lbs)
86 x 172 x 83 mm (WxHxD)
3.4 x 6.8 x 3.3 inch (WxHxD)
!
Notice
g to EN
cordin
c
a
l
a
v
ro
No app 4-23
5
N
E
d
an
al
approv
No VdS
P31.320.510 - 1en / 02.14
Approvals / marking
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 59
54-3
Product Sheet | Detecon
Means of alarm
Audible / visual
Sounder / Beacon YL5 MX
Order no.: 904206
ed
Audible and visual noti¿cation device for signalling ¿re
hazards. Equipped with an electronic module for operation
directly on a primary control group of the ¿re alarm panel via
a voltage increase.
PC, red
Enclosure material
ABS, red
Flash energy
5 joules
IP 54
-25 °C to +40 °C
(-13 °F to +104 °F)
-40 °C to +70 °C
(-40 °F to +158 °F)
max. 90 %
Ambient temperature
Relative humidity
Rated voltage
24 V DC
Power consumption
Luminous intensity
6W
140 cd
1 Hz = 60 Àashes / min.
Duty cycle
Tones
Sound pressure
D
Sound range
Weight
Dimensions
The combination unit can be operated via the voltage increase function as well as via the voltage reversal function at the
FMZ 5000 and FMZ 5000 mod S control panels. The device
has an integrated reverse polarity protection diode.
approx. 300 mA
is
Flash rate
Note
18 V - 30 V DC
co
Rated current consumption
Mounting hardware
n
Storage temperature
Operating voltage
Not included in delivery
ti
IP rating
1 Sounder / Beacon YL5 MX
n
Dome material
u
Included in delivery
Technical specifications
100 %
32
up to 110 dB (A) 1 m
approx. 1300 m2
(13993 square foot),
Ø 40 m (1575 inch)
810 g (1.8 lbs)
134 x 192 x 128 mm (WxHxD)
5.3 x 7.6 x 5 inch (WxHxD)
!
Notice
54-23
g to EN
in
d
r
o
c
c
3
roval a
EN 54No app
only on 19, 2017)
d
e
s
a
b
proval
l March
VdS ap ers (valid unti
d
n
for sou
P31.320.510 - 1en / 02.14
Approvals / marking
G 209134
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 60
Product Sheet | Detecon
Means of alarm
Audible / visual, addressable
Loop Sounder / Beacon LSBX 293r
Order no.: 912572
Analog addressable Loop Sounder / Beacon for acoustic and
optical alarms with integrated dual isolator in red. Addressing
is done via integrated DIP switches.
Included in delivery
ed
1 Loop Sounder / Beacon LSBX 293r
Not included in delivery
Mounting hardware
Technical specifications
IP rating
IP 21C
Technology / protocol
Loop AP / XP95
Sound pressure
up to100 db
red
Spherical cup colour
red
yes
-10 °C to +55 °C
(+14 °F to +131 °F)
18 V - 28 V DC
Operating temperature
Operating voltage
Weight
330 —A
290 g (0.64 lbs)
105 x 105 x 90 mm (WxHxD)
4.13 x 4.13 x 3.54 inch (WxHxD)
!
Notice
54-23
g to EN
in
d
r
o
c
c
3
roval a
EN 54No app
only on 0, 2014)
d
e
s
a
b
proval
l May 3
VdS ap ers (valid unti
d
n
for sou
P31.320.510 - 5en / 02.14
D
is
Dimensions
G 210023
9 mA
co
Rated current consumption
Approvals / marking
n
Integrated isolator
Operating current siren
Cable recommendation standard
J-Y(St)Y -2x2x0.8 mm, red
747180
Recommended cable
2-lead
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Electrostatic shielding
Not required
ti
Enclosure colour
u
PC
n
Enclosure material
Connection / mounting
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 61
Product Sheet | Detecon
Means of alarm
Audible / visual, addressable
Loop Sounder / Beacon LSBX 298r WP
Order no.: 912573
Analog addressable Loop Sounder / Beacon for acoustic and
optical alarms with integrated dual isolator in red. Addressing
is done via integrated DIP switches.
Included in delivery
ed
1 Loop Sounder / Beacon LSBX 298r WP
Not included in delivery
Mounting hardware
Technical specifications
IP rating
IP 66
Technology / protocol
Loop AP / XP95
Sound pressure
up to 100 db
red
Spherical cup colour
red
yes
-20 °C to +70 °C
(-4 °F to +158 °F)
18 V - 28 V DC
Operating temperature
Operating voltage
Weight
350 —A
294 g (0.65 lbs)
110 x 110 x 113 mm (WxHxD)
4.33 x 4.33 x 4.44 inch (WxHxD)
!
Notice
23
EN 54ing to
d
r
o
c
c
3
roval a
EN 54No app
only on 0, 2014)
d
e
s
a
b
proval
l May 3
VdS ap ers (valid unti
d
n
for sou
P31.320.510 - 5en / 02.14
D
is
Dimensions
G 210023
9 mA
co
Rated current consumption
Approvals / marking
n
Integrated isolator
Operating current siren
Cable recommendation standard
J-Y(St)Y -2x2x0.8 mm, red
747180
Recommended cable
2-lead
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Electrostatic shielding
Not required
ti
Enclosure colour
u
PC
n
Enclosure material
Connection / mounting
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 62
Product Sheet | Detecon
Means of alarm
Audible / visual, addressable
Loop Sounder / Beacon LSBX 005r WP
Order no.: 912574
Analog addressable Loop Sounder / Beacon for acoustic and
optical alarms with integrated dual isolator in red. Addressing
is done via integrated DIP switches.
Included in delivery
ed
1 Loop Sounder / Beacon LSBX 005r WP
Not included in delivery
Mounting hardware
Connection / mounting
Enclosure material
u
Technical specifications
PC
IP 65
Technology / protocol
Loop AP / XP95
Sound pressure
up to 100 db
red
ti
Enclosure colour
Spherical cup colour
red
yes
-20 °C to +60 °C
(-4 °F to +140 °F)
17 V - 28 V DC
n
Integrated isolator
Operating temperature
Rated current consumption
Weight
!
Notice
g to EN
ccordin
a
l
a
v
o
r
No app pproval
a
S
d
V
o
N
P31.320.510 - 5en / 02.14
D
is
0832-CPD-1051
333 —A
260 g (0.57 lbs)
104 x 97.5 mm (DxH)
4.09 x 3.84 inch (DxH)
Dimensions
Approvals / marking
8 mA
co
Operating voltage
Operating current siren
n
IP rating
Cable recommendation standard
J-Y(St)Y -2x2x0.8 mm, red
747180
Recommended cable
2-lead
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Electrostatic shielding
Not required
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 63
54-23
Product Sheet | Detecon
Means of alarm
Audible / visual, addressable
Loop Sounder / Beacon LSBX 006k WP
Order no.: 912583
Analog addressable Loop Sounder / Beacon for acoustic
and optical alarms with integrated dual isolator in clear glass.
Addressing is done via integrated DIP switches.
Included in delivery
ed
1 Loop Sounder / Beacon LSBX 006k WP
Not included in delivery
Mounting hardware
Technical specifications
PC
IP rating
IP 65
Technology / protocol
Loop AP / XP95
Sound pressure
up to 100 db
white
Spherical cup colour
clear
Operating voltage
Operating current siren
Rated current consumption
Weight
n
Operating temperature
8 mA
333 —A
260 g (0.57 lbs)
104 x 97.5 mm (DxH)
4.09 x 3.84 inch (DxH)
!
Notice
EN
ing to
accord
l
a
v
o
r
No app pproval
a
No VdS
P31.320.510 - 5en / 02.14
D
is
Dimensions
Approvals / marking
yes
-10 °C to +55 °C
(+14 °F to +131 °F)
17 V - 28 V DC
co
Integrated isolator
ti
Enclosure colour
Cable recommendation standard
J-Y(St)Y -2x2x0.8 mm, red
747180
Recommended cable
2-lead
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Electrostatic shielding
Not required
n
Enclosure material
u
Connection / mounting
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 64
54-23
Product Sheet | Detecon
Means of alarm
Audible / visual, addressable
Base Sounder / Beacon BSBX 334
Order no.: 912584
Detector Base Sounder / Beacon with integrated dual isolator. Addressing is done via integrated DIP switches.
Included in delivery
ed
1 Base Sounder / Beacon BSBX 334
1 Addressing card
Not included in delivery
Mounting hardware
Technical specifications
PC
Sound pressure
up to.85 db
Technology / protocol
Loop AP / XP95
white
Flashlight circle colour
clear
ti
Enclosure colour
Integrated isolator
yes
-20 °C to +60 °C
(-4 °F to +140 °F)
17 V - 28 V DC
Operating voltage
Operating current siren
300 —A
160 g (0.35 lbs)
115 x 38 mm (DxH)
4.53 x 1.49 inch (DxH)
!
Notice
4-23
to EN 5
g
in
d
r
cco
roval a
N 54-3
ly on E
No app
n
)
o
d
e
0, 2014
bas
proval
l May 3
VdS ap ers (valid unti
nd
for sou
P31.320.510 - 5en / 02.14
D
is
Dimensions
G 207103
8 mA
co
Weight
Approvals / marking
n
Operating temperature
Rated current consumption
Cable recommendation standard
J-Y(St)Y -2x2x0.8 mm, red
747180
Recommended cable
2-lead
Conductor cross-section max. 2.5 mm2 (0.004 square inch)
Electrostatic shielding
Not required
n
Enclosure material
u
Connection / mounting
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 65
Product Sheet | Detecon
Means of alarm
Audible / visual
LWA-90 red RNB lighted warning display
Order no.: 910178
Illuminated warning display with super bright LEDs in a pro¿le
aluminium housing with RNB standard text on the reverse
side of printed front window and two end caps for lateral
cable insertion. Very bright and homogeneous illumination of
the printed surface via use of a light guide body and laterally
radiating super bright LEDs. The light display can be con¿gured to Àashing or continuous light via DIP switch and the
built-in buzzer turned on or off.
Product features
Technical specifications
Operating voltage
Output voltage
Light colour
Light surface
Operating temperature
Enclosure material
•
21 V - 29 V DC
24 V DC
red
240 x 90 mm (WxH)
9.4 x 3.5 inch (WxH)
-40 °C to +85 °C
(-40 °F to +104 °F)
aluminium, black
IP rating
IP 50
Weight
Dimensions
993 g (2.2 lbs)
300 x 120 x 35 mm (WxHxD)
11.8 x 4.7 x 1.4 inch (WxHxD)
•
•
•
•
Standard text, „Achtung! Raum nicht betreten Löschung
ausgelöst“ (RNB)
The warning display is maintenance-free
DIP switch for con¿guring continuous or Àashing light
Buzzer activation (approx. 70 dB)
Optional relay contact to activate an external signal
generator
Included in delivery
1 LWA-90 lighted warning display, red RNB, without
mounting hardware
LWA-90 IP 54 red RNB lighted warning
display
Order no.: 911746
Technical specifications
IP rating IP 54, otherwise like Order no. 910178
1000 g (2.2 lbs)
P31.320.510-4en / 02.14
Weight
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 66
Product Sheet | Detecon
Means of alarm
Audible / visual
LWA-90 red RV lighted warning display
Order no.: 910179
Illuminated warning display with super bright LEDs in a pro¿le
aluminium housing with RV standard text on the reverse side
of printed front window and two end caps for lateral cable
insertion. Very bright and homogeneous illumination of the
printed surface via use of a light guide body and laterally radiating super bright LEDs. The light display can be con¿gured
to Àashing or continuous light via DIP switch and the built-in
buzzer turned on or off.
Product features
Technical specifications
Operating voltage
•
21 V - 29 V DC
Output voltage
Light colour
Light surface
Operating temperature
Enclosure material
24 V DC
red
240 x 90 mm (BxH)
9.4 x 3.5 inch (WxH)
-40 °C to +85 °C
(-40 °F to +104 °F)
aluminium, black
IP rating
IP 50
Weight
Dimensions
•
•
•
•
Standard text „Achtung! Raum verlassen Löschung
ausgelöst“ (RV)
The warning display is maintenance-free
DIP switch for con¿guring continuous or Àashing light
Buzzer activation (approx. 70 dB)
Optional relay contact to activate an external signal
generator
Included in delivery
1 LWA-90 lighted warning display, red RNB, without
mounting hardware
993 g (2.2 lbs)
300 x 120 x 35 mm (WxHxD)
11.8 x 4.7 x 1.4 inch (WxHxD)
LWA-90 IP 54 red RV lighted warning
display
Order no.: 916293
Technical specifications
IP rating IP 54, otherwise like Order no. 910179
1000 g (2.2 lbs)
P31.320.510-4en / 02.14
Weight
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 67
Product Sheet | Detecon
Means of alarm
Audible / visual
LWA-90 red RSV lighted warning display
Order no.: 910180
Illuminated warning display with super bright LEDs in a pro¿le
aluminium housing with RSV standard text on the reverse
side of printed front window and two end caps for lateral
cable insertion. Very bright and homogeneous illumination of
the printed surface via use of a light guide body and laterally
radiating super bright LEDs. The light display can be con¿gured to Àashing or continuous light via DIP switch and the
built-in buzzer turned on or off.
Product features
Technical specifications
Operating voltage
Output voltage
Light colour
Light surface
Operating temperature
Enclosure material
•
21 V - 29 V DC
24 V DC
red
240 x 90 mm (BxH)
9.4 x 3.5 inch (WxH)
-40 °C to +85 °C
(-40 °F to +104 °F)
aluminium, black
IP rating
IP 50
Weight
Dimensions
•
•
•
•
Standard text „Achtung! Raum sofort verlassen
Löschung ausgelöst“ (RSV)
The warning display is maintenance-free
DIP switch for con¿guring continuous or Àashing light
Buzzer activation (approx. 70 dB)
Optional relay contact to activate an external signal
generator
Included in delivery
1 LWA-90 lighted warning display, red RSV, without
mounting hardware
993 g (2.2 lbs)
300 x 120 x 35 mm (WxHxD)
11.8 x 4.7 x 1.4 inch (WxHxD)
LWA-90 IP 54 red RSV lighted warning
display
Order no.: 916294
Technical specifications
IP rating IP 54, otherwise like Order no. 910180
1000 g (2.2 lbs)
P31.320.510-4en / 02.14
Weight
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 68
Product Sheet | Detecon
Means of alarm
Audible / visual
LWA-90 red KT lighted warning display
Order no.: 910181
Illuminated warning display with super bright LEDs in a pro¿le
aluminium housing with optional custom text on the reverse
side of printed front window and two end caps for lateral
cable insertion. Very bright and homogeneous illumination of
the printed surface via use of a light guide body and laterally
radiating super bright LEDs. The light display can be con¿gured to Àashing or continuous light via DIP switch and the
built-in buzzer turned on or off.
Product features
Technical specifications
Operating voltage
21 V - 29 V DC
Output voltage
Light colour
Light surface
Operating temperature
Enclosure material
24 V DC
red
240 x 90 mm (BxH)
9.4 x 3.5 inch (WxH)
-40 °C to +85 °C
(-40 °F to +104 °F)
aluminium, black
IP rating
IP 50
Weight
Dimensions
•
•
•
•
•
Custom text: Any text or graphic can be chosen!
The warning display is maintenance-free
DIP switch for con¿guring continuous or Àashing light
Buzzer activation (approx. 70 dB)
Optional relay contact to activate an external signal
generator
Included in delivery
1 LWA-90 lighted warning display, red KT, without
mounting hardware
993 g (2.2 lbs)
300 x 120 x 35 mm (WxHxD)
11.8 x 4.7 x 1.4 inch (WxHxD)
LWA-90 IP 54 red KT lighted warning
display
Order no.: 911747
Technical specifications
IP rating IP 54, otherwise like Order no. 910181
1000 g (2.2 lbs)
P31.320.510-4en / 02.14
Weight
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 69
Product Sheet | Detecon
Means of alarm
Audible / visual
LWA-130 red KT lighted warning display
Order no.: 910182
Illuminated warning display with super bright LEDs in a pro¿le
aluminium housing with optional custom text on the reverse
side of printed front window and two end caps for lateral
cable insertion. Very bright and homogeneous illumination of
the printed surface via use of a light guide body and laterally
radiating super bright LEDs. The light display can be con¿gured to Àashing or continuous light via DIP switch and the
built-in buzzer turned on or off.
Product features
Technical specifications
Operating voltage
Output voltage
Light colour
Light surface
Operating temperature
Enclosure material
21 V - 29 V DC
24 V DC
red
240 x 130 mm (BxH)
9.4 x 3.5 inch (WxH)
-40 °C to +85 °C
(-40 °F to +104 °F)
aluminium, black
IP rating
IP 50
Weight
Dimensions
•
•
•
•
•
Custom text: Any text or graphic can be chosen!
The warning display is maintenance-free
DIP switch for con¿guring continuous or Àashing light
Buzzer activation (approx. 90 dB)
Optional relay contact to activate an external signal
generator
Included in delivery
1 LWA-130 lighted warning display, red KT, without
mounting hardware
1395 g (3.1 lbs)
346 x 166 x 35 mm (WxHxD)
13.6 x 6.5 x 1.4 inch (WxHxD)
LWA-130 IP 54 red KT lighted warning
display
Order no.: 911748
Technical specifications
IP rating IP 54, otherwise like Order no. 910182
1403 g (3.09 lbs)
P31.320.510-4en / 02.14
Weight
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 70
Product Sheet | Detecon
Means of alarm
Audible / visual
V2A base for LWA-90/-130
Order no.: 910185
For preassembly of the LWA-90/-130 lighted warning
displays.
Included in delivery
1 base V2A
3 countersunk screws and dowels
2 screws M4 x 20 mm
Technical specifications
Material
Dimensions
V2A
280 x 110 x 11 mm (BxHxT)
11 x 4.3 x 0.4 inch (BxHxT)
V2A head cover for LWA-90/-130
Order no.: 910184
Weather protection for the LWA-90/-130 lighted warning
displays.
Included in delivery
V2A head cover without mounting hardware
Technical specifications
Material
V2A
Weight
Dimensions
760 g (1.7 lbs)
340 (cover), 300 (rear panel)
x 120 x 95 mm (BxHxT)
13.4 (cover), 11.5 (rear panel)
x 4.7 x 3.7 inch (BxHxT)
IP65 LWA-90 weatherproof housing
Order no.: 910186
Weatherproof housing of transparent acrylic for use of LWA90 lighted warning display.
Consisting of rear panel and housing upper part, preassembled base bottom section for receiving the lighted warning
display.
Included in delivery
IP65 housing without mounting hardware
Technical specifications
Enclosure material
P31.320.510-4en / 02.14
Weight
Dimensions
Acryl
1895 g (4.2 lbs)
350 x 150 x 65 mm (BxHxT)
+ overhang 40 mm
13.8 x 5.9 x 2.6 inch (BxHxT)
+ overhang 1.6 inch
Notes
To obtain an IP 65 rating, the standard illuminated warning
signals (IP 50) can be used in combination with the weatherproof housing. Illuminated warning signals with an IP 54 rating
are not necessary in this case.
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 71
Product Sheet | Detecon
Means of alarm
Audible / visual
IP65 LWA-130 weatherproof housing
Order no.: 910187
Technical specifications
Weatherproof housing of transparent acrylic for use of LWA130 lighted warning display.
Weight
otherwise like Order no.: 910186
Notes
To obtain an IP 65 rating, the standard illuminated warning
signals (IP 50) can be used in combination with the weatherproof housing. Illuminated warning signals with an IP 54 rating
are not necessary in this case.
P31.320.510-4en / 02.14
Dimensions
2459 g (5.4 lbs)
400 x 200 x 65 mm (BxHxT)
+ overhang 40 mm
15.8 x 7.9 x 2.6 inch (BxHxT)
+ overhang 1.6 inch
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 72
Product Sheet | Detecon
Means of alarm
Audible / visual Ex
Sounder / Beacon YL60 MX Ex
Order no.: 910657
Audible and visual alarm device for signalling danger of ¿re
that is especially suitable for use in industrial environments
with hazard areas in zone 1 as well as 21. Equipped with
electronic module for operation directly on a primary control
group of the ¿re alarm panel via a voltage increase. The
robust aluminium housing is resistant to sea water, environmental effects and chemicals.
Product features
Included in delivery
•
Explosion-proof device for hazardous zone 1 as well
as 21.
•
Max. 110 dB (A) / 1 m omnidirectional sound output.
1 Sounder / Beacon YL60 MX Ex
1 Dust cover
1 Blanking plug
•
32 standardised tone sequences selectable.
•
2-stage alarm, independently selectable 2nd stage.
•
Tone selection via DIL switch.
•
Fitted as standard with protective cage.
Not included in delivery
Mounting hardware
Connection / mounting
Recommended cable
Conductor cross-section:
Technical specifications
Spherical calotte material
Horn material
Enclosure material
IP rating
Operating temperature
Storage temperature
Rated voltage
ABS, red
Aluminium, red
IP 66
-35 °C to +60 °C (T4 / T135°C)
(-31 °F to +140 °F (T4 / T135°C))
-35 °C to +40 °C (T6 / T85°C)
(-31 °F to +104 °F (T6 / T85 °C))
-35 °C to +60 °C
(-31 °F to +140 °F)
24 V DC
Operating voltage
18 V - 30 V DC
Rated current consumption
approx. 570 mA
Power consumption
Flash energy
Flash rate
Note
The combination unit can be operated via the voltage increase function as well as via the voltage reversal function at the
FMZ 5000 and FMZ 5000 mod S control panels. The device
has an integrated reverse polarity protection diode.
Approvals / marking
Ex classi¿cation:
x II 2G Ex d IIB T4 Ta -35°C to +60°C Gb
x II 2G Ex d IIB T6 Ta -35°C to +40°C Gb
x II 2D Ex tb IIIC T135°C Ta -35°C to +60°C Db IP66
x II 2D Ex tb IIIC T85°C Ta -35°C to +40°C Db IP66
13.7 W
5J
1 Hz = 60 Àashes / min.
Tones
32
Sound pressure
Relative humidity
P31.320.520en / 02.14
PC, red
2-lead
2.5 mm2 (0.004 square inch)
Weight
Dimensions
up to 110 dB (A) 1 m
max. 95%
6000 g (13.2 lbs)
420 x 145 mm (HxD)
16.5 x 5.7 inch (HxD)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 9 - 73
Product Sheet | Detecon
Gas detection
Gas detection
Carbon dioxide alarm GMX IR/CO2
Order no.: 896500
Gas detection and alarm unit monitoring areas with possible
leakage of carbon dioxide. The warning unit can also be used
in CO2 extinguishing systems, during and after the extinguishing in rooms next to the extinguishing zone.
Easy installation and commissioning with power plug.
Product features
Included in delivery
•
Stand alone CO2 detection and alarm unit.
•
Alarm level 1.5 and 3.0 Vol %.
•
4 high power relays, floating contacts.
•
Internal sounder, option external sounder connection.
1 Carbon dioxide alarm GMX IR/CO2
1 Operating manual, German
1 Operating manual, English
Fastening material
Power cable
Not included in delivery
Technical specificationes
Detection method
IR-Absorption
Response time t90
ca. 120 s
Cross sensitivity
Operating voltage
Power cord
Relays
Contacts
Ready to operate indication
Fault indication
Alarm indication
Pre-alarm, self-resetting
Main-alarm, self-locking
Acoustic sensor
Operating temperature
Air pressure
Installation position
Mounting hight
IP rating (EN 60529)
P31.340.010en / 02.13
Enclosure material
Relative humidity
(IEC721-3-3)
Weight
Dimensions
896883
800938
can be ignored
230V (±15%), 50 Hz, 3 VA
2.0 m (78.7 inch) long, grey
1 main-alarm, 1 pre-alarm,
1 fault, 1 sounder
dry floating contacts
8 A / 250 V AC
1 LED green
1 LED yellow
Cable gland PG9 (for external units)
For the functional check:
- Calibration cap GMX IR/CO2
- Test gas extraction device
- Test gas bottle (3 Vol. %)
- Test gas bottle (3.3 Vol. %)
675818
800018
902932
909523
909524
Notes
The device labels are in German and English.
Approvals / marking
Type examination certificate:
IBS/PFG-Nr. 41 300 996
acc. to TRSK 313
1 LED red at 1.5 Vol.% CO2
1 LED red at 3.0 Vol% CO2
integrated
0 °C to +40 °C
(+32 °F to +104 °F)
90 - 110 kPa
Diffusion sensor downwards
At ground level,
approx. 150 mm above ground
IP 54
Aluminium,
RAL3000-red
10 to +90 %
no condensation
2.8 kg (6.2 lbs)
160 x 220 (with sensor) x 90 mm
(BxHxT)
6.3 x 8.7 (with sensor) x 3.5 inch
(BxHxT)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 10 - 1
Product Sheet | Detecon
Door hold - open technique
Door hold - open technique
TSZ 5000
Order no.: 909292
The magnetic door holder panel TSZ 5000 is intended for the
control of classified fire doors, fire gates and fire dampers by
means of hold - open devices.
If a fire detector should detect smoke or if a manual call
point is activated, the TSZ 5000 interrupts the power supply
to the holding solenoids immediately, and the fire doors are
automatically closed by the door closer. Simultaneously, the
relay contact opens and possibly connected signal devices or
controls are activated.
Product features
Included in delivery
•
Power output for hold - open devices.
•
Floating detector contacts for fault and alarm.
•
Automatic door locking, opening of smoke dampers,
disconnection of machines.
1 door lock panel TSZ 5000
1 cable gland M20x1.5
3 cable glands M16x1.5
1 dummy plug M20x1.5
3 dummy plugs M16x1.5
4 screws 3.5x35 and dowel pins
Technical specifications
Operating temperature
Operating voltage
Rated voltage
Power rating
Relay contact voltage
IP rating
-10 °C to +40 °C
(+14 °F to +104 °F)
100 V - 260 V AC
24 V DC
10 W
30 V DC
IP 64
Relative humididy
Enclosure material
Enclosure colour
Weight
Plastics
Approved fire detectors:
Optical smoke detector OMX ORB
905567
Heat detector WMX ORB A1R
905565
Multisensor detector OWMX ORB
905566
Detector base BAX ORB
905564
The instruction / user manual is only avaible in German.
Approvals / marking
Z-6.5-2067
Light grey, RAL 7035
550 g (1.2 lbs)
160 x 130 x 60 mm (WxHxD)
6.3 x 5.1 x 2.4 inch (WxHxD)
P31.350.010en / 01.14
Dimensions
max. 95 %
Note
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 11 - 1
Product Sheet | Detecon
Door hold - open technique
Door hold - open technique
Holding solenoid 490 N / base plate
Order no.: 909327
The holding solenoid with its base plate can be used for
wall mounting. The standard electric connection occurs via
double-pole terminals.
Product features
•
Technical specifications
Rated voltage
24 V DC
Rated current
63 mA
Wattage rating
1.5 W
Adhesive force
490 N
0 °C to + 50 °C
(+32 °F to +122 °F)
-30 °C to +70 °C
(-22 °F to +158 °F)
100 %
Operating temperature
Storage temperature
Duty cycle
Holding solenoid diameter
Integrated reverse protection diode and suppressor diode
Approvals / marking
G 23097
0786-CPD-20249
50 mm (2 inch)
IP rating
IP 65
Weight
Dimensions
400 g (0.9 lbs)
65 x 93 x 33 mm (WxHxD)
2.6 x 3.7 x 1.3 inch (WxHxD)
Holding solenoid 490 N / housing with
pushbutton
Order no.: 909328
The holding solenoid with its steel base plate in a closed
housing is a surface-mount design and can be used for wall
mounting. An interrupt button is integrated, and the electric
connection is carried out from the rear side.
Product features
•
Technical specifications
24 V DC
Rated current
63 mA
Wattage rating
1.5 W
Adhesive force
490 N
0 °C to +50 °C
(+32 °F to +122 °F)
-30 °C to +70 °C
(-22 °F to +158 °F)
100 %
Storage temperature
P31.350.010en / 01.14
Approvals / marking
Rated voltage
Operating temperatur
Duty cycle
Holding solenoid diameter
IP rating
Incorporated reverse protection diode and suppressor
diode
G 23097
0786-CPD-20249
50 mm (2 inch)
IP 65
Weight
Dimensions
450 g (1 lbs)
85 x 105 x 37,5 mm (WxHxD)
3.4 x 4.1 x 1.5 inch (WxHxD)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 11 - 2
Product Sheet | Detecon
Door hold - open technique
Door hold - open technique
Holding solenoid 490 N / length 185 mm
(7.3 inch)
Order no.: 909329
Through modification the holding solenoid can be used for
wall, ceiling or floor mounting. The tube can be shortened to
110 and/or 145 mm (floor/wall mounting) so that almost any
kind of distance between door and wall can be bridged.
Product features
•
Technical specifications
Rated voltage
24 V DC
Rated curren
63 mA
Wattage rating
1.5 W
Adhesive force
490 N
0 °C to +50 °C
(+32 °F to +122 °F)
-30 °C to +70 °C
(-22 °F to +158 °F)
100 %
Operating temperature
Storage temperature
Duty cycle
Holding solenoid diameter
Incorporated reverse protection diode and suppressor
diode
Approvals / marking
G 23097
0786-CPD-20249
50 mm (2 inch)
IP rating
IP 65
Weight
Dimensions
820 g (1.8 lbs)
90 x 185 x 105 mm (WxHxD)
3.5 x 7.3 x 4.1 inch (WxHxD)
Holding solenoid 490 N / length 335 mm
(13.2 inch)
Order no.: 909330
Otherwise like Order no. 909329
Technical specifications
Weight
Dimensions
900 g (2 lbs)
90 x 335 x 105 mm (WxHxD)
3.5 x 13.2 x 4.1 inch (WxHxD)
Order no.: 909411
Anchor plate flexible design
Anchor plate with flexible connecting piece for establishing
the magnetic connection between fire door and door holding
solenoid. In general, the diameter of the anchor plate is
slightly larger than that of the corresponding holding solenoid.
Thus, mounting imprecision does not have any effect on the
adhesive force.
Product features
Technical specifications
P31.350.010en / 01.14
Operating temperature
Storage temperature
Plate diameter
Weight
Dimensions
0 °C to +50 °C
(+32 °F to +122 °F)
-30 °C to +70 °C
(-22 °F to +158 °F)
55 mm (2.2 inch)
•
•
Compensating inclination angle up to 5 °C (+41 °F)
with rubber bearing
200 g (0.4 lbs)
55 x 55 x 18 mm (WxHxD)
2.2 x 2.2 x 0.7 inch (WxHxD)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 11 - 3
Product Sheet | Detecon
Door hold - open technique
Door hold - open technique
Anchor plate with hinged joint
Order no.: 909412
Anchor plate with flexible connecting piece and hinged joint
for establishing the magnetic connection between fire door
and door holding solenoids. In general, the diameter of the
anchor plate is slightly larger than that of the corresponding
holding solenoid. Thus, mounting imprecision does not have
any effect on the adhesive force.
Product features
Technical specifications
Operating temperature
Storage temperature
Plate diameter
Weight
Dimensions
0 °C to +50 °C
(+32 °F to +122 °F)
-30 °C to +70 °C
(-22 °F to +158 °F)
55 mm (2.2 inch)
•
•
Pivoting in two directions up to 60 °C (+140 °F)
Fixable in any position
180 g (0.4 lbs)
55 x 55 x 50 mm (WxHxD)
2.2 x 2.2 x 2 inch (WxHxD)
Hand switch for magnetic door holder
system, surface-mount
Order no.: 909413
Push-button of surface-mount design for manual activation of
locking systems with the inscription „Tür schließen!“.
Note
Only these push-button are suitable for operation in locking
systems according to DiBt.
Technical specifications
Operating temperature
Enclosure material
Weight
Dimensions
0°C to +50°C
(+32 °F to +122 °F)
Plastics
270 g (0.6 lbs)
62.5 x 62.5 x 37 mm (WxHxD)
2.5 x 2.5 x 1.5 inch (WxHxD)
Hand switch for magnetic door holder
system, flush mounting
Order no.: 909414
Push-button of flush-mounted design for manual activation of
locking systems with the inscription „Tür schließen!“.
Note
Only these push-button are suitable for operation in locking
systems according to DiBt.
P31.350.010en / 01.14
Technical specifications
Operating temperature
Enclosure material
Weight
Dimensions
0°C to +50°C
(+32 °F to +122 °F)
Plastics
200 g (0.4 lbs)
81 x 81 x 45 mm (WxHxD)
3.2 x 3.2 x 1.8 inch (WxHxD)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 11 - 4
Product Sheet | Detecon
Cable/installation material
Cable/installation material
Fire alarm cable FireLine 750, red
NEW
Special fire alarm cable (red, halogen-free) for signal transmission in facilities in dry and moist locations.
For fixed cable installations.
Quantity unit for orders = metres.
Technical specifications
Cable shielding
Included in delivery
Fire-resistant according
aluminium foil, drain wire
IEC 60654
(non-corrosive fire gases)
IEC 60332-1-2
IEC 60332-3-22
IEC 60331-21
UV-protected according
IEC 60068-2-5
Halogen-free according
Flame-retardant according
batch size as required: cable coil or cable drum
Note
This cable type must not be used in areas in where a function
integrity according to VDE DIN 4102-12/E30 is required.
Smoke emission according
IEC 61034
during installation R=6xD
Min. bending radius
fixed installation R=4xD
-40 °C up to +70 °C
Temperature range
(+40 °F up to +158 °F)
Min. installation temperature
-15 °C (5 °F)
batch number, cable type / diameter,
Cable identification
manufacturing month /-year,
manufacturer name, lenght marking
designation
P51.520.10-01en / 03.14
FireLine 750
906331
number of conductors
& cross-section
n x mm2 (square inch)
2 x 1.0 (0.001)
906333
2 x 1.5 (0.002)
8.0 (0.3)
95 (209.4)
906335
2 x 2.5 (0.004)
9.5 (0.4)
135 (297.6)
906337
3 x 1.0 (0.001)
7.9 (0.3)
90 (198.4)
906339
3 x 1.5 (0.002)
8.5 (0.3)
110 (242.5)
906341
3 x 2.5 (0.004)
9.8 (0.4)
155 (341.7)
906343
4 x 1.0 (0.001)
8.5 (0.3)
105 (231.5)
906345
4 x 1.5 (0.002)
9.2 (0.4)
130 (286.6)
906347
4 x 2.5 (0.004)
10.6 (0.4)
185 (407.8)
906349
7 x 1.0 (0.001)
10.0 (0.4)
150 (330.7)
906351
7 x 1.5 (0.002)
11.0 (0.4)
195 (429.9)
906493
7 x 2.5 (0.004)
12.6 (0.5)
280 (617.3)
907404
12 x 1.0 (0.001)
13.0 (0.5)
240 (529.1)
906494
12 x 1.5 (0.002)
14.2 (0.6)
305 (672.4)
906495
12 x 2.5 (0.004)
16.8 (0.7)
450 (992.1)
907981
19 x 1.0 (0.001)
15.5 (0.6)
340 (749.6)
906496
19 x 1.5 (0.002)
16.5 (0.6)
450 (992.1)
906497
19 x 2.5 (0.004)
20.0 (0.8)
680 (1499.1)
908512
3 x 1.5 S* (0.002)
8.5 (0.3)
110 (242.5)
order no.
outer diameter
approx. mm (inch)
7.5 (0.3)
weight
approx. kg/km
(lbs/ 0.62 miles)
80 (176.4)
* Special colour code: black, blue, green yellow
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 12 - 1
Product Sheet | Detecon
Cable/installation material
Cable/installation material
Fire alarm cable FireLine E 30, red
NEW
Special fire alarm cable (red, halogen-free) with function
integrity E 30 according EN 50288-7 for signal transmission
in facilities in dry and moist locations.
For fixed cable installations.
Quantity unit for orders = metres.
Technical specifications
Lead identification
DIN VDE 0293-308:01/2003-01
System circuit integrity
VDE DIN 4102-12/E30
Cabel shielding
Fire-resistant according
aluminium foil, drain wire
IEC 60654-1
and IEC 60754-2
(non-corrosive fire gases)
IEC 60332-1-2
IEC 60332-3-22
IEC 60331-21
UV-protected according
IEC 60068-2-5
Halogen-free according
Flame-retardant according
Smoke emission according
IEC 61034-2
during installation R=6xD
Min. bending radius
fixed installation R=4xD
-40 °C up to +70 °C
Temperature range
(+40 °F up to +158 °F)
Min. installation temperature
-15 °C (+5 °F)
batch number cable type / diameter,
Cable identification
manufacturing month /-year,
manufacturer name, lenght marking
designation
P51.520.10-01en / 03.14
FireLine E30
Included in delivery
batch size as required: cable coil or cable drum
Note
The function integrity E 30 can be reached in combination
with suitable assambly materials and correct installation only.
Approvals / marking
applied for
906332
number of conductors
& cross-section
n x mm2 (square inch)
2 x 1.0 (0.001)
906334
2 x 1.5 (0.002)
9.3 (0.3)
125 (275.6)
906336
2 x 2.5 (0.004)
11.1 (0.4)
180 (396.8)
906338
3 x 1.0 (0.001)
9.3 (0.3)
120 (264.5)
906340
3 x 1.5 (0.002)
9.8 (0.4)
144 (317.5)
917816
3 x 2.5 (0.004)
11.8 (0.4)
209 (460.7)
906344
4 x 1.0 (0.001)
10.0 (0.4)
139 (306.4)
906346
4 x 1.5 (0.002)
10.8 (0.4)
171 (376.9)
906348
4 x 2.5 (0.004)
13.0 (0.5)
252 (555.5)
906350
7 x 1.0 (0.001)
12.0 (0.5)
207 (456.3)
906352
7 x 1.5 (0.002)
12.8 (0.5)
270 (595.2)
907403
7 x 2.5 (0.004)
15.6 (0.6)
382 (842.1)
907405
12 x 1.0 (0.001)
15.9 (0.6)
334 (736.3)
907408
12 x 1.5 (0.002)
17.1 (0.7)
417 (919.3)
907409
12 x 2.5 (0.004)
20.9 (0.8)
603 (1329.4)
910887
19 x 1.0 (0.001)
18.7 (0.7)
481 (1060.4)
907410
19 x 1.5 (0.002)
20.1 (0.8)
600 (1322.7)
907431
19 x 2.5 (0.004)
24.7 (0.9)
919 (2026.0)
906342
3 x 1.5 S* (0.002)
9.8 (0.4)
144 (317.5)
order no.
outer diameter
approx. mm (inch)
7.9 (0.3)
weight
approx. kg/km
(lbs/ 0.62 miles
91 (200.6)
* Special colour code: black, blue, green yellow
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 12 - 2
Product Sheet | Detecon
Cable/installation material
Cable/installation material
Cable J-Y(St)Y - 2x2x0.8 mm (0.03 inch) Ø,
red
Order no.: 747180
Fire alarm cable (red) for signal transmission in facilities in
dry and moist plant locations. For installation inside and on
wall.
Quantity unit for orders = metres.
Included in delivery
1 packaging unit (cable coil 200m (0.12 miles))
Technical specifications
Line resistance at 20 °C
(68 °F)
Isolating resistance
at 20 °C (68 °F)
Operating capacity at 800 Hz
≥ 100 MOhm / km (0.6 miles)
Capacitive couplings at 800 Hz
≤ 500 pF / km (0.6 miles)
≤ 36.6 Ohm / km (0.6 miles)
≤ 120 nF / km (0.6 miles)
Inductance at 800 Hz
approx. 0.7 mH / km (0.6 miles)
≤ 300 V,
not for high-voltage applications
-30 °C to +70 °C
(-22 °F to +158 °F)
-5 °C to +50 °C
(+23 °F to +123 °F)
6 mm (0.2 inch)
Operating voltage
Temperature range for fixed
installation
Temperature range for
flexible installation
Outer diameter
Specification according to
Weight
VDE 0815
approx. 57 g / m (0.1 lbs / 39 inch)
Cable JE-H(St)H - 2x2x0.8 mm (0.03 inch) Ø,
orange
Order no.: 907940
Fire alarm cable (orange) with E 30 circuit integrity for signal
transmission in facilities in dry and moist plant locations. For
installation in and on wall.
Fire detection in accordance with VDE 0482 Part 266-2,
DIN EN 50266-2/ IEC 60332-3 (corresponds to
DIN VDE 0472 Part 804 test method C).
E 30: circuit integrity in accordance with DIN 4102 Part 12.
Technical specifications
Line resistance at 20 °C
(68 °F)
Isolating resistance
at 20 °C (68 °F)
Operating capacity at 800 Hz
≥ 100 MOhm / km (0.6 miles)
Capacitive couplings at 800 Hz
≤ 200 pF / 100m (0.06 miles)
Inductance at 800 Hz
P51.520.10-01en / 03.14
Operating voltage
Temperature range for fixed
installation
Temperature range for
flexible installation
Outer diameter
Minimum bending radius
Specification
Weight
≤ 36.6 Ohm / km (0.6 miles)
≤ 120 nF / km (0.6 miles)
Leads are only stranded as star quad, not in pairs.
Quantity unit for orders = metres.
Included in delivery
1 packaging unit (cable coil 100 m (0.06 miles))
approx. 0.7 mH / km (0.6 miles)
≤ 225 V,
not for high-voltage applications
-30 °C to +70 °C
(-22 °F to +158 °F)
-5 °C to +50 °C
(+23 °F to +122 °F)
7.5 mm (0.3 inch)
6 x cables Ø
according to VDE 0815
approx. 74 g / m (1.6 lbs / 39 inch)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 12 - 3
Product Sheet | Detecon
Cable/installation material
Cable/installation material
Cable LiYCY - 5 x 0.5 mm2
(0.0007 square inch), shielded
Order no.: 606061
Data cable (grey)
Quantity unit for orders = meters
Included in delivery
1 packaging unit (cable coil 100 m (0.06 miles))
Technical specifications
Line resistance at 20 °C
(68 °F)
Isolating resistance
at 20 °C (68 °F)
Operating capacity:
- lead/lead
- lead/shield
Inductance
Operating voltage
Temperature range
for fixed installation
Outer diameter
≤ 39 Ohm / km (0.6 miles)
≥ 20 MOhm / cm (0.4 inch)
≤ 120 nF / km (0.6 miles)
≤ 160 nF / km (0.6 miles)
approx. 0.65 mH / km (0.6 miles)
≤ 250 V,
not for high-voltage applications
-30 °C to +80 °C
(-22 °F to +176 °F)
7 mm (0.3 inch)
Specification according to
Weight
VDE 0812
approx. 68 g / m (1.5 lbs / 39 inch)
Cable JE-Y(St)Y - 2x2x0.8 mm (0.03 inch) Ø,
blue Ex
Order no.: 140084
Fire alarm cable (blue) for signal transmission in facilities in
dry and moist plant locations. For installation in and on wall.
Quantity unit for orders = meters
Included in delivery
1 packaging unit (cable coil 200 m (0.12 miles))
Technical specifications
Line resistance at 20 °C
(68 °F)
Isolating resistence
at 20 °C (68 °F)
Operating capacity
bei 800 Hz
P51.520.10-01en / 03.14
Operating voltage
Temperature range
for fixed installation
Temperature range
for flexible installation
Outer diameter
Minimum bending radius
Specification according to
Weight
≤ 36.6 Ohm / km (0.6 miles)
≥ 100 MOhm / km (0.6 miles)
≤ 144 nF / km (0.6 miles)
≤ 225 V,
not for high-voltage applications
-30 °C to +70 °C
(-22 °F to +158 °F)
-5 °C to +50 °C
(-22 °F to +158 °F)
5.9 mm (0.2 inch)
6 x cables Ø
VDE 0815
approx. 66 g / m (1.5 lbs / 39 inch)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 12 - 4
Product Sheet | Detecon
Cable/installation material
Cable/installation material
Cable gland M16/M20x1.5Ms
Order no.: 907096
Easily installed cable gland with large sealing and terminal
connection area for wide cable diameters.
Can be used as EMC cable gland, with integrated strain relief
and anti-twist protection.
To replace the standard M16 cable glands on the UniVario
detector base for M20 installations.
Included in delivery
Cable gland M 16 / M 20 x 1,5 MS
Technical specifications
Material
Connection thread
Terminal connection area
Protection rating
Ambient temperature
Weight
Not included in delivery
Brass, nickel-plated
Viton sealing ring and O-ring
M16 x 1.5
Cold-shrink tube, silicone, 25 > 6 mm (1 > 0.2 inch)
Gland M 16 x 1.5 Ms
905337
901861
9 - 13 mm (0.4 -0.5 inch)
IP 68 (5 bar)
-20 °C to +100 °C
(-4 °F to +212 °F)
34 g (0.1 lbs)
Cold-shrink tube 25 > 6 mm (1 > 0.2 inch)
Order no.: 905337
Cold-shrink tube for installation of detectors or electrical
devices in outdoor areas, in shipbuilding or for demanding
sealing requirements, such as in machine tools.
Easy installation, without tools. Reliable, durable sealing
without heat application. Moisture resistance and resistance
to acids, alkalis, ozone and UV. Non-flammable.
Included in delivery
Cold-shrink tube, silicone, 25 > 6 mm (1 > 0.2 inch)
Note
Technical specifications
Material
Silicone rubber
Cable diameter
Colour
P51.520.10-03en / 03.14
6 to 25 mm (0.2 to 1 inch)
Length
black
-55 °C to +260 °C
(-67 °F to +500 °F)
125 mm (4.9 inch)
Weight
11 g (0.02 lbs)
Operating temperature
The installation of the shrink tube is irreversible.
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 12 - 5
Product Sheet | Detecon
Cable/installation material
Cable/installation material
Cable gland M20x1.5 MS with twin insertion
Order no.: 887705
Technical specifications
Material
Brass, nickel-plated
Terminal connection area
2 x Ø 6 mm (0.2 inch)
-20 °C to +100 °C
(-4 °F to +212 °F)
31 g (0.07 lbs)
Operating temperature
Weight
Not included in delivery
Gland M 20 x 1.5 PA
Cable gland M20x1.5 Ms with twin insertion
801722
Order no.: 908690
Technical specifications
Terminal connection area
2 x Ø 8 mm (0.3 inch)
Otherwise like Order no. 887705.
Cable gland M20x1.5 PA 6-3 with double
insertion
Order no.: 886323
Technical specifications
Material
Plastic, PA 6-3
Terminal connection area
2 x Ø 6 mm (0.2 inch)
-20 °C to +100 °C
(-4 °F to +212 °F)
10 g (0.01 lbs)
Operating temperature
Weight
Not included in delivery
Gland M 20 x 1,5 PA
Cable gland M20x1.5 PA 6-3 with twin
insertion
801722
Order no.: 908751
Technical specifications
Terminal connection area
2 x Ø 8 mm (0.3 inch)
P51.520.10-03en / 03.14
Otherwise like Order no. 886323.
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 12 - 6
Product Sheet | Detecon
Cable/installation material
Cable/installation material
Adapter M16 x1.5Ms
Order no.: 908609
Adapter for cable glands.
Included in delivery
1 adapter M 16 x 1.5 MS
1 O-Ring Di 13 x 1.5 Viton
Technical specifications
Material
Mail thread
Brass, nickel-plated
Viton sealing ring and O-ring
M16 x 1.5
Female thread
NPT 1/2"
-55 °C to +120 °C
(-67 °F to +248 °F)
30 g (0.07 lbs)
Ambient temperature
Weight
Adapter M16 x1.5Ms - NPT 3/4“
Order no.: 908808
Technical specification
Included in delivery
Material
Mail thread
Brass, nickel-plate
Viton sealing ring and O-ring
M16 x 1.5
Female thread
NPT 3/4“
Wrench size
27
-55 °C to +120 °C
(-67 °F to +248 °F)
80 g (0.2 lbs)
Ambient temperature
Weight
Adapter M16 x1.5Ms - NPT 1“
Order no.: 908810
Technical specification
Included in delivery
Material
Mail thread
Female thread
Wrench size
Ambient temperature
P51.520.10-03en / 03.14
1 adapter M 16 x 1.5 - NPT 3/4“ MS gal. Ni
1 O-Ring Di 13 x 1.5 Viton
Weight
Brass, nickel-plate
Viton sealing ring and O-ring
M16 x 1.5
1 adapter M 16 x 1.5 - NPT 1“ MS gal. Ni
1 O-Ring Di 13 x 1.5 Viton
NPT 1“
32
-55 °C to +120 °C
(-67 °F to +248 °F)
110 g (0.2 lbs)
© Viking GmbH & Co. KG | Industriestr. 10/12 | D-23843 Bad Oldesloe | www.viking-emea.com |
Chapter 12 - 7
Europe, Middle East & Africa
BENELUX
Hinmanweg 11d
NL-7575 BE Oldenzaal
The Netherlands
Tel.: +31 (0)541 573233
Fax: +31 (0)541 573234
vikingnetherlands@vikingcorp.com
CENTRAL & EASTERN EUROPE
Industriestr. 10/12
D-23843 Bad Oldesloe
Germany
Tel.: +49 (0)4531 803 8087
Fax: +49 (0)4531 803 137
contact@viking-emea.com
FRANCE
IBÉRICA
Mar Cantábrico, 10
P. I. San Fernando I
San Fernando de Henares
E-28830 Madrid
Spain
Tel.: +34 91 677 8352
Fax: +34 91 677 8498
vikingspain@vikingcorp.com
4, rue Marconi
BP 25180
F-57075 Metz Cedex 03
France
Tel.: +33 (0)800 10 29 23
Fax: +33 (0)800 88 70 46
vikingfrance@vikingcorp.com
ITALY
Via Pogliano, 26/a
I-20020 Lainate (MI)
Italy
Tel.: +39 02 932 851 1
Fax: +39 02 932 851 30
vikingitaly@vikingcorp.com
PC1.5.1/0313-0914/en
NORDIC
MIDDLE EAST
Post Box No. 17531
Jebel Ali Free Zone, Dubai
United Arab Emirates
Tel.: +971 (0)4 8895 561
Fax: +971 (0)4 8895 562
vikingdubai@vikingcorp.com
S-192 78 Sollentuna
Sweden
Tel.: +46 (0)8 594 415 90
Fax: +46 (0)8 591 280 18
vikingsweden@vikingcorp.com
POLAND
ul. Płaskowickiej Filipiny 46/33
PL-02 778 Warsaw
Poland
Tel.: +48 22 403 57 90
Fax: +48 22 403 57 69
vikingpoland@vikingcorp.com
TURKEY
İnönü Cad. Sümer Sok.
Zitaş İş Merkezi D2 Blok K:5, D:12
34742 Kozyatağı, Kadıköy, İstanbul
Turkey
T: +90 (0)216 403 18 00
F: +90 (0)216 403 18 03
vikingturkey@vikingcorp.com
UK & IRELAND
Unit 2 - Byram House, Newborn Court
Chapel Street
Epworth DN9 1HQ
United Kingdom
Tel.: +44 (0)1427 871 000
Fax: +44 (0)1427 873 917
vikinguk@vikingcorp.com
For further information, please visit
www.viking-emea.com
In all cases the full product datasheet remains the reference document
Information, photos and drawings are not contractually binding
Photos
Cover: R&R Communication bv
Viking S.A. | Z.I. Haneboesch | L-4562 Differdange / Niederkorn | Luxembourg | vikinglux@vikingcorp.com | www.viking-emea.com
Download PDF
Similar pages