Tripp Lite
1111 West 35th Street
Chicago, IL 60609 USA
Telephone: +(773) 869 1234
E-mail: saleshelp@tripplite.com
Model #: SMART1500RMXLN
SmartPro 1.5kVA 1.35kW Line Interactive Extended Run UPS, Sine wave, Pre-installed SNMPWEBCARD, 2U,
LCD, USB, Serial, EPO, 120V
Highlights
1.5kVA / 1500VA / 1350 watt line interactive 2U rack / tower UPS, 0.9 power
factor
120V nominal output during brownouts to 83V and overvoltages to 145V
Interactive LCD provides UPS status information and advanced configuration
options
USB, RS232, EPO and Pre-installed SNMPWEBCARD interface
Expandable runtime, Hot-swap batteries, 95% efficiency, Sine wave output
2 independently switchable output load banks
NEMA 5-15P input, 8 NEMA 5-15R outlets
Description
Tripp Lite SmartPro Line Interactive UPS with enhanced LCD interface offers network-grade power protection for critical server, network and
telecommunications equipment. Line Interactive Uninterruptible Power Supply (UPS) with built-in Auto-Voltage Regulation (AVR) actively corrects
brownouts and overvoltages back to usable levels while maintaining a full battery charge in case of power failure. Tripp Lite's unique configuration
excels in exceptionally poor-power environments with two separate levels of voltage boost to correct both slight undervoltages and severe brownout
conditions. Interactive LCD interface reports UPS operating mode, detailed UPS and site-power data, plus enables a variety of UPS setup and
configuration options. Super-fast switchover from line to battery power occurs within milliseconds to maintain operation of connected equipment
without interruption or reboot. 95% line-mode efficiency offers reduced heat emissions and operating costs. Network management interfaces support
communications via USB, RS-232 and Pre-installed SNMPWEBCARD network interface. HID-compliant USB interface enables integration with
built-in power management and auto shutdown features of Windows and Mac OS X. Network communications ports enable detailed monitoring of
equipment load levels, self-test data and utility power conditions. Includes PowerAlert monitoring software and complete cabling. Switched output
load banks enable scheduled and real-time remote reboot and load shedding of select outlets. Emergency Power Off (EPO) interface. LCD display
panel easily rotates for viewing in rackmount or tower configurations. Audible alarm with push-button momentary alarm-cancel and silent-mode
configuration options. Programmable self-test. Field-replaceable, hot-swappable battery modules.
Package Includes
SMART1500RMXLN UPS system with Pre-installed SNMPWEBCARD
PowerAlert software with USB, Serial & EPO cabling
4 post installation kit
Owner's manual
Features
Tripp Lite SMART1500RMXLN line interactive 2U rack/tower UPS with 1500VA / 1.5kVA / 1350W capacity and extended runtime options
Line interactive UPS with Automatic Voltage Regulation (AVR) corrects brownouts and overvoltages from 83 to 145V
NEMA 5-15P input plug; 8 NEMA 5-15R output receptacles, Two independently switched output load banks
Maintains uninterrupted operation of connected networking equipment during blackouts, surges, brownouts and overvoltages
High 95% efficiency rating in line-power mode offers reduced power consumption and BTU emisssions
Internal batteries offer 14 minutes at 50% load (675W) and 4.9 minutes at 100% load (1350W)
Extended runtime is available with optional BP36V15-2U (limit 1) OR BP36V42-3U (no limit), Output is reduced to 1200 watts maximum with
external battery packs
External battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual)
Hot-swappable, user-replaceable internal batteries and external battery packs can be replaced with no disruption to connected equipment
Front panel LCD monitoring screen with MODE and ENTER buttons reports operating mode with 5-bar battery charge graphic, plus 7
selectable screens of detailed UPS and site power information
LCD interface also supports a number of advanced user setup and operating preferences
Ships with 4 post rackmount installation hardware; Optional 2POSTRMKITWM enables 2 post rackmount/wallmount installation; Optional
2-9USTAND enables tower placement
Built-in USB, RS-232 and Pre-installed SNMPWEBCARD accessory monitoring options
HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X
Included PowerAlert UPS monitoring software; Built-in Emergency Power Off (EPO) interface with cable
Specifications
OUTPUT
Output Volt Amp
Capacity (VA)
1500
Output kVA capacity
(kVA)
1.5
Output Watt Capacity
(watts)
1350
Output kW capacity
1.35
Output power factor
0.9
Output Capacity
Details
Output derates to 1200 watts in all external battery configurations
Nominal Output
Voltage(s) Supported
120V
Frequency
compatibility
60 Hz
Output voltage
regulation (line mode)
-14%, +6%
Output voltage
regulation (Battery
mode)
+/- 5%
Built-in UPS output
receptacles
8 5-15R outlet(s)
Built-in controllable
switched load banks
Two switchable two-outlet 5-15R load banks
Output AC waveform
(AC mode)
Sine wave
Output AC waveform
(battery mode)
Pure Sine wave
INPUT
Rated input current
(at maximum load)
12A
Nominal Input
Voltage(s) Supported
120V AC
UPS input
connection type
5-15P
Input circuit breaker
15A
UPS Input cord
length (ft.)
10
UPS Input cord
length (m)
3
Recommended
Electrical Service
15A 120V
BATTERY
Full load runtime
(minutes)
4.9 min. (1350w)
Half load runtime
(minutes)
14 min. (675w)
Expandable battery
runtime
Extended runtime supported via optional external battery packs
External battery pack
compatibility
BP36V15-2U (limit 1); BP36V42-3U (multi-pack compatible)
DC system voltage
(VDC)
36
Battery recharge rate
(included batteries)
Less than 4.5 hours from 10% to 90%
Replacement battery
cartridge (internal
UPS battery
replacement)
RBC93-2U
Battery Access
Front panel battery access door
Battery replacement
description
Hot-swappable, user replaceable batteries
VOLTAGE REGULATION
Voltage regulation
description
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 145
Overvoltage
correction
Input voltages between 127 and 145 are reduced by 12%
Undervoltage
correction
Input voltages between 95 and 108 are boosted by 12%
Severe undervoltage
correction
Input voltages between 83 and 94 are boosted by 24%
LEDS ALARMS & SWITCHES
Front panel LCD
display
Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data,
plus configuration of voltage, operating mode, alarm function and a variety of additional options (see manual for
detailed LCD configuration and monitoring options)
Alarms
Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions
Alarm cancel
operation
Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option
available
Switches
3 pushbutton switches control OFF / ON power status, MODE selection and MUTE / ENTER control functions
SURGE / NOISE SUPPRESSION
UPS AC suppression
joule rating
570
UPS AC suppression
response time
Instantaneous
EMI / RFI AC noise
suppression
Yes
PHYSICAL
Installation form
factors supported
with included
accessories
4 post 19 inch rackmount (mounting rail kit included)
Included mounting
accessory description
Adjustable mounting rail kit included
Installation form
factors supported
with optional
accessories
2 post rackmount (2POSTRMKITWM); Wallmount (2POSTRMKITWM); Tower (2-9USTAND)
Primary form factor
Rackmount
UPS / Power Module
dimensions in
primary form factor
(height x width x
depth / inches)
3.45 x 17.3 x 13.45
UPS / Power Module
dimensions in
primary form factor
(height x width x
depth / cm)
8.8 x 43.9 x 34.2
Installed whole
system total rack
space height (rack
spaces)
2U
Secondary form
factor
Tower (requires 2-9USTAND)
UPS / Power Module
weight (lbs)
46.5
UPS / Power Module
weight (kg)
21.1
UPS Shipping
dimensions (height x
width x depth /
inches)
7.9 x 22.9 x 19.4
UPS Shipping
dimensions (height x
width x depth / cm)
20.1 x 58.2 x 49.3
Shipping weight (lbs)
51.3
Shipping weight (kg)
23.3
UPS housing material
Steel
Cooling method
Fan
ENVIRONMENTAL
Operating
Temperature Range
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature
Range
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity
0 to 95%, non-condensing
AC mode BTU / hr.
(full load)
237
COMMUNICATIONS
Communications
interface
USB; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface
Network monitoring
port description
Includes Pre-installed SNMPWEBCARD network interface. Supports detailed monitoring of UPS and site power
conditions
PowerAlert software
Included
Communications
cable
USB and DB9 cabling included
WatchDog
compatibility
Supports Watchdog application, OS and hard-reboot restart options for remote applications
LINE / BATTERY TRANSFER
Transfer time
4 milliseconds (AC to battery mode), 1 millisecond (Battery to AC mode)
Low voltage transfer
to battery power
(setpoint)
83
High voltage transfer
to battery power
(setpoint)
145
SPECIAL FEATURES
Grounding lug
Back panel grounding lug
Cold Start (startup in
battery mode during
a power failure)
Cold-start operation supported
High availability UPS
features
Hot swappable batteries
Green & high
efficiency features
Greater than 95% efficiency - GREEN UPS; Individually controllable load banks
CERTIFICATIONS
UPS Certifications
Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category B (EMI);
ROHS (Restriction of Hazardous Substances)
WARRANTY
Product Warranty
Period (Worldwide)
2-year warranty, 3 year with registration. Note: registration is required for 3-year warranty.
Connected
Equipment Insurance
(U.S., Canada &
Puerto Rico)
$250,000 Ultimate Lifetime Insurance
Related Items
Optional Products
Related Model
Description
Qty.
WEXT5-500-1500
5-Year Extended Warranty - For Smart Line-Interactive and Online Tower or Rack
models, 1500VA or less
1
ENVIROSENSE
Monitors temperature, humidity and contact-closure inputs. (Requires UPS with
SNMPWEBCARD, monitored PDU or switched PDU.)
1
SRSWITCH
Magnetic Door Switch Kit for front and rear doors; requires ENVIROSENSE
1
MODBUSCARD
For remote monitoring and control via MODBUS protocol
1
2-9USTAND
Enables Tower Placement of Rackmount UPS Systems
1
2POSTRMKITWM
Enables 2-Post Rackmount or Wallmount Installation of Select Rackmount UPS Systems
1
BP36V15-2U
BP36V15-2U - External Battery Pack for UPS System
1
BP36V42-3U
BP36V42-3U - External Battery Pack for UPS System
1
RBC93-2U
2U UPS Replacement Battery Cartridge for select Tripp Lite SmartPro UPS
1
PDUB15
Single-Phase Hot-Swap PDU, 15A 120V, 2U Horizontal Rackmount, 8 NEMA 5-15R
outlets, set of 2 NEMA 5-15P input plugs
1
PDU1215
Single-Phase Basic PDU, 15A 120V, 1U Horizontal Rackmount, 13 NEMA 5-15R outlets,
NEMA 5-15P input plug
1
PDUNV
Single-Phase Basic PDU, 16A 100-240V, 1U Rackmount, C13 C19 outlets, C20 input
and C14, L6-20P, L5-20P, 5-20P and 5-15P adapters
1
PDUV15
Single-Phase Basic PDU, 15A 120V, 0U Vertical Rackmount, 14 NEMA 5-15R outlets,
NEMA 5-15P input plug
1
PDUMH15
Single-Phase Metered PDU, 15A 120V, 1U Horizontal Rackmount, 13 NEMA 5-15R
outlets, NEMA 5-15P input plug
1
PDUMV15
Single-Phase Metered PDU, 15A 120V, 0U Vertical Rackmount, 16 NEMA 5-15R outlets,
NEMA 5-15P input plug
1
PDUMH15AT
Single-Phase Auto Transfer Switch / Metered PDU, 15A 120V, 1U Horizontal
Rackmount, 8 NEMA 5-15R outlets, 2 NEMA 5-15P inputs
1
PDUMNH15
Single-Phase Monitored PDU, 15A 120V, 1U Horizontal Rackmount, 8 NEMA 5-15R
outlets, NEMA 5-15P input plug
1
PDUMNV15
Single-Phase Monitored PDU, 15A 120V, 0U Vertical Rackmount, 16 NEMA 5-15R
outlets, NEMA 5-15P input plug
1
PDUMH15ATNET
Single-Phase Auto Transfer Switch / Switched PDU, 15A 120V, 1U Horizontal
Rackmount, 8 NEMA 5-15R outlets, 2 NEMA 5-15P inputs
1
PDUMV15NET
Single-Phase Switched PDU, 15A 120V, 0U Vertical Rackmount, 16 NEMA 5-15R
outlets, NEMA 5-15P input plug
1
P007-002
2-ft. Heavy-Duty 14AWG Power cord (IEC-320-C13 to NEMA 5-15P)
1
P007-006
6-ft. Heavy-Duty 14AWG Power cord (IEC-320-C13 to NEMA 5-15P)
1
P007-010
10-ft. Heavy-Duty 14AWG Power cord (IEC-320-C13 to NEMA 5-15P)
1
P010-012
12-ft. 18AWG Power cord (NEMA 5-15P to IEC-320-C13)
1
P022-001
1-ft. 18AWG Power Extension cord (NEMA 5-15R to NEMA 5-15P)
1
P023-001
1-ft. 14AWG Power Adapter cord (NEMA L5-15R to NEMA 5-15P)
1
P034-010
10-ft. 14AWG Heavy Duty Power cord ( IEC-320-C19 to NEMA 5-15P)
1
More information, including related products, owner's manuals, and additional technical specifications, can be found online at
www.tripplite.com/en/products/model.cfm?txtModelID=5429.
Copyright © 2013 Tripp Lite. All rights reserved. All trademarks are the sole property of their respective owners. Tripp Lite has a policy of continuous
improvement. Specifications are subject to change without notice. Photos may differ slightly from final products.
Download PDF
Similar pages