SkyPanel® Series S30 / S60 / S120

SkyPanel® Series
S30 / S60 / S120
C and RP Versions
SAFETY AND INSTALLATION MANUAL
L5.0015041
© 2015 - 2017 Arnold & Richter Cine Technik GmbH & Co. Betriebs KG (ARRI). All rights reserved. Information subject to change without notice. ARRI and all affiliated companies disclaim liability for any injury, damage, direct or indirect loss, consequential or economic loss or any other loss occasioned by the
use of, inability to use or reliance on the information contained in this document. The ARRI logo, the ARRI
name and all other trade-marks in this document pertaining to services or products by ARRI or its affiliates and subsidiaries are trademarks or licensed by ARRI or its affiliates or subsidiaries.
ARRI and the ARRI logo are registered trademarks of the Arnold & Richter Cine Technik GmbH & Co.
Betriebs KG.
No part of this document may be used for distribution, reproduction, transmission, transcription, storage
in a data retrieval system, or translated into any language in any form by any means without the prior
written permission of ARRI®. If you are downloading files from our web pages for your personal use,
make sure to check for updated versions. ARRI® cannot take any liability whatsoever for downloaded
files, as technical data are subject to change without notice.
Art-NetTM Designed by and Copyright Artistic Licence Holdings Ltd.
L5.0015041
SkyPanel S30 (manual version)
Dimensions
Dimensions
SkyPanel S30 (p.o. version)
33
Dimensions
SkyPanel S60 (manual version)
SkyPanel S60 (p.o. version)
4
Dimensions
SkyPanel S120-C (manual version)
SkyPanel S120-C (p.o. version)
55
Dimensions ..................................................................................................................................................... 3
Content
Content
Safety Information .......................................................................................................................................... 9
Risk Levels and Alert Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Vital Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
General Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Introduction .................................................................................................................................................. 13
Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Overview ....................................................................................................................................................... 14
Manual Version . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
P.O. Version . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Connector Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Power Supply Unit S60 / S120 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Power Supply Unit S30 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Physical Installation ..................................................................................................................................... 17
To Mount the Stirrup and the Spigot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
To Mount the Safety Loop Brackets or SkyPanel Side Handles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
To Install the SkyPanel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Basic Features .............................................................................................................................................. 20
DMX / RDM Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
USB-Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Ethernet-Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
To power and use the SkyPanel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
To Power the SkyPanel ................................................................................................................................ 22
AC Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
DMX ............................................................................................................................................................... 24
Error Codes .................................................................................................................................................. 25
Specification Specification ......................................................................................................................... 26
77
Always follow these instructions and instructions printed on the product or given in the documentation shipped with
the product to protect against injury to yourself and damage to the product or other objects.
Risk Levels and Alert Symbols
Safety Information
Safety Information
Safety warnings, safety alert symbols, and signal words in these instructions indicate different risk levels:
DANGER!
DANGER indicates an imminent hazardous situation which, if not avoided, will result in death or
serious injury.
WARNING!
WARNING indicates a potentially hazardous situation which, if not avoided, may result in death or
serious injury.
CAUTION!
CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or
moderate injury.
NOTICE
NOTICE explains practices not related to physical injury. No safety alert symbol appears with this
signal word.
99
Safety Information
Vital Precautions
DANGER!
Hight voltage! Risk of electric shock and fire.
Read and understand all safety information and operation instructions before you operate or install
the product or the system.
Not to observe the safety information or general rules of reason may cause injury or death to yourself
and others or damage to equipment.
Use solely and exclusively as described in the instructions.
Always check that the local AC power matches the voltage and frequency range printed on the type
label of the product before use.
Use only a genuine ARRI PSU and connection cable designed for the SkyPanel.
When using a battery pack, always check that the voltage matches the voltage range printed on the
type label of the product before connecting the battery pack to the product.
Never use the cables for transportation. Never hang the product on its cables. Do not hang a battery
pack on its connection cable to the product.
Do not open the product. There are no user serviceable parts inside.
Never attempt to repair any part of the product on your own. Maintenance and repair work is only to
be carried out by an authorized ARRI service center.
Do not bypass or remove any safety feature of the product.
Warnings
WARNING!
Humidity and Condensation! Risk of electric shock and fire.
Never expose the product to rain or moisture. Do not use the product for 2 h when it was exposed
to big temperature differences as condensed moisture may damage the product electrically when
switched on.
Do not bend the power cable directly after the connector. Water could immerse and cause short circuits and damage the connector.
WARNING!
Overheating! Risk of fire.
Do not operate the product if the ambient temperature exceeds 45° C.
Intensive use can cause the surface to become hot (up to 80° C). Let the product cool down complete before you handle it.
Never cover air vents during operation. Keep a minimum clearance around the air vents of 0.5 m
(1.65 ft.).
Never point a light beam from another luminaire into the diffuser. Do not place the product on or
nearby heat sources. Intense heat cause damage to the product or automatic power off during operation.
10
Intense Light! Risk of injury and fire.
Do not stare at a operating light source.
Intense light. Do not stare at the light output aperture. Risk of irreversible eye injury. Wear safety
glasses. Keep a minimum distance to an illuminated surface, object or person of 1.0 m (3.3 ft).
Safety Information
WARNING!
The product must not be used without a diffuser installed.
WARNING!
Heavy weight! Risk of injury and damage.
Devices and accessories must be secured against fall when mounted above floor level. Always observe common and local safety regulations.
The stirrup shipped with the product must be mounted hanging or standing vertically. Lateral load
can cause deformation or breaking of the spigot and the stirrup.
Disconnect all cables prior to transport.
General Precautions
NOTICE
ARRI® SkyPanel® products are intended for professional use and may only be operated by qualified
persons. They are not for household use.
Please follow the user manual of accessories and third party accessories such as battery packs and
battery chargers. They contain important safety and security information.
Never attempt to repair any part of the product on your own. Maintenance and repair work is only to
be carried out by an authorized ARRI service center.
In addition to regular visible checks ARRI recommends that all electric components are checked for
electrical safety by a professional every 12 month. Keep the protocol of the check.
Help protecting the environment by disposing the package material at your local recycling center.
All components comply to the guidelines listed below:
• Low voltage directive 2014/35/EU
• EMC directive 2014/30/EU
• RoHS directive 2011/65/EU
Please observe the information given in the „Safety leaflet ARRI lampheads“ (L5.40731.E). The
leaflet is available for download on our web site www.arri.com.
Replacing the Light Source
NOTICE
The light source contained in this luminaire is not replaceable. If the light source has reached the
end of its operational life, the entire lamp must be replaced.
If the light source fails before it reached the end of its specified operational life, please contact the
manufacturer or his service agent or a similar qualified person.
11
11
Safety Information
Firmware Downgrade
NOTICE
Please observe, that it is not possible to downgrade the firmware to a version lower 1.0.0 after updating to version 1.0.0 or higher.
Maintenance Information
NOTICE
Do not clean the surface of the product with solvents or strong detergents.
Clean the product with a soft cloth wetted with a mild detergent. Do not rub the surface: lift stuck
particles off with a soft repeated press.
Clean soiled electric contacts with cotton swabs wetted with isopropyle alcohol.
Keep electric contacts clean and replace corroded parts.
Intended Use
NOTICE
This product is intended to illuminate persons and objects in a dry environment. Always follow the
safety information. Any usage other than described above is not permitted and can damage the
product and lead to associated risks such as short-circuit, fire, electric shock, etc. You are not allowed to modify the product.
12
Thank you for selecting the SkyPanel LED softlight from ARRI. The SkyPanel is a compact, ultra-bright and
high-quality LED softlight. It is much more efficient than a softlight with a conventional light source.
Introduction
Introduction
The SkyPanel combines the advantages of the LED technology with the characteristic of a conventional
softlight. The SkyPanel integrates seamlessly into established working practice. Lighting designers as well
as Studios don’t need to change their workflow.The optical system produces a soft, homogeneous light
field.
The different models of the SkyPanel emit white light with a fixed color temperature or colored light with
adjustable color temperature and adjustable green / magenta point (see “Specification” on page 26). The
light spectrum is optimized for excellent color rendition and fulfills Art-Netthe demands of modern, digital
cameras. All models of the SkyPanel can be controlled using the common DMX512-A protocol, RDM,
sACN, Art-Net or the fixture menu.
The SkyPanel is powered by AC power or a battery pack. Please find more detailed information in section
“To Power the SkyPanel” on page 22.
Please find detailed information about the features and use of the SkyPanel soft light in the user manual.
The user manual is available for download on the ARRI web site www.arri.com.
Unpacking
NOTICE
Product and packaging contain recyclable materials. Always store, ship, and dispose of according
to local regulations.
ARRI is not liable for consequences from inadequate storage, shipment or disposal.
The SkyPanel is supplied with:
• External power supply unit (PSU)
• Power cable with a powerCON TRUE1 connector and a
power plug or bare ends
• Connector cable between power supply unit and SkyPanel
• Stirrup
• 28 mm spigot
• Short instruction
• 10 mm allen key (manual version S30 and S60)
• 8 mm allen key (p.o. version S30, S60 and S120, manual version S120)
• 4 mm allen key
Please refer to chapter “Specification” on page 26 for more information about optional accessories.
13
13
Overview
Overview
Manual Version
Handle
Stirrup
Top Latches
Diffusor or Remote Phosphor Panel
Fixture Menu
Spigot
Tilt Lock
Connector Panel
Tilt Lock Lever
Figure 1: Front and back view, manual version (the figure shows the S60)
14
Overview
P.O. Version
Handle
Stirrup
Top Latches
Diffusor or Remote Phosphor Panel
Fixture Menu
Connector Panel
Spigot
P.O. Drives
Figure 2: Front and back view p.o. version (the figure shows the S30)
15
15
Overview
Connector Panel
USB-A
port
Boot
DMX mode
In
DMX
Thru
Ethernet
connector
Power in 48 V=
Battery in
23 - 36 V =
Figure 3: Connector panel
Power Supply Unit S60 / S120
Power Out
48 V DC
Main switch
Main power in
and thru
Figure 4: Power supply unit S60 / S120
Power Supply Unit S30
Front panel
Power Out
48 V DC
16
Rear panel
Main power in
and thru
Figure 5: Power supply unit S30
Main switch
WARNING!
Risk of falling! Risk of injury.
Attach an approved safety-cable to secure the product and accessories against clamp or bracket
failure when the product is mounted above floor. The safety-cable needs to be approved at least 10
times the weight of the product including all accessories mounted at the product. The safety cable
must comply with EN 60598-2-17 Section 17.6.6 and be approved by an official body such as TÜV.
Lead the safety-cable through the stirrup (or the eyelet when using a P.O. version) and keep it as
short as possible. The handle and the floor stand must not be used as an anchor for the safety-cable.
Physical Installation
Physical Installation
The stirrup must be mounted hanging or standing vertically. Lateral load can cause deformation or
breaking of the spigot and the stirrup.
The rigging structure needs to be approved for the weight of all devices, equipment and cables installed on it.
Due to its width the SkyPanel S120 can oscillate and damage objects or injure persons when falling
into the safety-cable. Two safety cables on either side of the fixture are recommended to reduce this
occurrence.
Block access below the work area and work from a stable platform whenever installing, servicing or
moving the product or accessories.
NOTICE
Do not illuminate the display and the diffuser plate by high power light beams from a short distance.
The display and the light engine are damaged by high brightness and heat radiation within very short
time.
To Mount the Stirrup and the Spigot
You need:
• a 10 mm allen key (manual version)
• a 8 mm allen key (p.o. version)
• a 4 mm allen key
• a torque wrench with 10 mm or 8 mm and 4 mm allen socket
To Mount the Spigot (manual version)
Place the spigot on the 13 mm hole in the middle of the stirrup. Insert the allen screw with washer and spring
washer and tighten it with a torque wrench to 37 ft-lb. torque.
To Mount the Spigot (p.o. version)
Insert the allen screw with washer and spring washer in the spigot. Place the spigot on the upper side of
the gear in the middle of the spigot. Tighten the allen screw with a torque wrench to 22 ft-lb. torque.
17
17
Physical Installation
To Mount the Stirrup
The fixture is shipped with the stirrup not mounted. Mount the stirrup to the fixture if you want to use the
stirrup:
• Place the SkyPanel with the lighting aperture facing downwards on an even and clean surface.
• Remove two allen screws (4 mm allen key) on each side of the product.
• Insert both connector elements on both sides of the stirrup into the holder on each side of the SkyPanel
(see Figure 6).
• Mount the stirrup with two allen screws on each side of the product (4 mm allen key, recommended torque:
5 ft-lb.).
Figure 6: To mount the stirrup
To Mount the Safety Loop Brackets or SkyPanel Side Handles
The stirrup holders can be used to attach the safety loop brackets or side handles in conjunction with the
Center mount yoke (L2.0008078) and Fixed center mount yoke (L2.0008080). The brackets or side handles
are intended to be used as an anchor point for a safety cable.
To Dismantle the Stirrup
• Place the SkyPanel with the lighting aperture facing downwards on an even and clean surface.
• Loosen and remove two allen screws on each side of the product (4 mm allen key, see Figure 6).
• Remove the stirrup.
To mount the Safety Loop Brackets or Side Handles
• Place the SkyPanel with the lighting aperture facing downwards on an even and clean surface.
• Place one safety loop bracket in the holder on each side of the SkyPanel, or
• Slide one side handle over the holder on each side of the SkyPanel (see Figure 7).
• Mount the safety loop brackets or side handles with two allen screws on each side of the product (4 mm
allen key, torque: 5 ft-lb.).
Figure 7: To mount the safety loop brackets or side handles
18
NOTICE
Always observe all safety information given above when mounting the SkyPanel and accessories.
Keep care that:
• Both guiding rails are locked.
• Tripods are set up in a stable position. Tripods need to be approved for the load they need
to carry.
• The use of sand bags are recommended on all tripods to increase stability.
Physical Installation
To Install the SkyPanel
Always observe the additional load of cables and accessories!
19
19
Basic Features
Basic Features
Pan and Tilt (manual version)
Loose the mounting screw of the tripod or the appropriate fixing screw of the mounting clamp to pan the
SkyPanel. Tighten the screw to avoid unintended movement. Loose the tilt-lock to tilt the SkyPanel to the
desired angle. Tighten the tilt-lock-lever to avoid unintended movement.
Pan and Tilt (p.o. version)
Pan and Tilt the SkyPanel by turning the white and blue wheel by hand or pole.
Use of Accessories for Beam Shaping
You can mount accessories like barn doors,
snoots, honey combs or egg crates by using the
guiding rails on the front side of the SkyPanel:
• Un-lock both top latches by sliding both levers
completely inwards and open the cover strip
(see Figure 8).
• Insert the accessory from the top completely
into the guiding rails.
• Close the cover strip.
• Lock both top latches by sliding both levers
completely outwards (see Figure 8).
Top latch unlocked
Top latch locked
Figure 8: Locking top latches
To Mount a Barndoor
A barndoor is mounted using the outer guiding rails
(see Figure 9).
To mount a barndoor on the S30 and S60:
• Close the cover strip. Lock both top latches by
sliding both levers completely outwards (see Figure 8).
• Insert the barndoor completely into the outer guiding rails until both safety catches snap in.
To mount a barndoor on the S120:
• Un-lock both top latches by sliding both levers
completely
inwards and open the cover strip (see Figure 8).
Figure 9: To mount a barndoor
• Insert the barndoor completely into the outer and
inner guiding rails.
• Close the cover strip. Lock both top latches by sliding both levers completely outwards (see Figure 8).
DMX / RDM Interface
The SkyPanel has a DMX / RDM-interface. It has locking 5-pin XLR connectors for DMX / RDM data input
and throughput. Please find more detailed information how to establish a DMX / RDM data-link in chapter
“DMX” on page 24.
20
NOTICE
Disconnect all DMX cables from the product before using an USB memory stick. The data transfer
between the product and the USB memory stick might be disturbed due to interferences.
Basic Features
USB-Port
Do not use service features during a show or a shot. The data transfer between the product and the
controller might be disturbed due to interferences.
The USB-A connector can power small USB devices. The maximum current is 500 mA @ 5V. Do
not overload the USB-A connector.
The SkyPanel has an USB-A connector to upload firmware, upload and download fixture settings and preset lists or download error and service logs using an USB memory stick. The memory stick must be formatted with the FAT32 file system. The firmware upload file must be stored in the root directory of the memory
stick.
Ethernet-Interface
The SkyPanel has an RJ45 EtherCON port for the control via Art-Net, uploading firmware and setting parameters. The Ethernet port can be used for service purposes like downloading error reports from the product and set certain data. To do so you need a software tool, the ARRI Lighting Service Manager (ALSM)
and an RJ45 network cable to connect your PC with the SkyPanel.
Download the ALSM free of charge from the ARRI web site www.arri.com/lightingsoftware.
Please find more detailed information to work with the ALSM in the user manual of the software. The manual is included in the download package.
To power and use the SkyPanel
WARNING!
Intense light! Danger of eye injury.
Do not stare at the operating light source.
After switching on the SkyPanel initializes for a few seconds and is ready for operation. The SkyPanel will
operate with the settings made on the fixture menu or received by DMX, sACN or Art-Net.
21
21
To Power the SkyPanel
To Power the SkyPanel
DANGER
High voltage! Risk of electric shock and fire.
For protection from electric shock, always connect the external power supply unit electrically to
ground (earth) when connected to AC power. The AC mains power supply must be fitted with a fuse
or circuit breaker and ground-fault (earth-fault) protection.
Use only an ARRI power supply unit and an ARRI connector cable. The use of other power supply
units and connector cables might cause malfunction and damage of the product.
WARNING!
Intense light! Risk of eye injury. Use an eye protection.
Ensure that persons do not look at the light emission aperture without eye protection when the product is connected to AC power or a battery pack. The product can light up suddenly. The high intensity light beam of the product can cause eye irritation or injury when not respecting the safety
distance.
NOTICE
Always connect the product direct to AC power. Do not connect it to a dimmer-system. Doing so will
damage the product.
AC Power
The SkyPanel is powered by an external power supply unit (PSU). The PSU is an auto-sensing switchmode power supply that automatically adapts to AC power at 110 - 240 V ~, 50 / 60 Hz (nom.).
Make sure that no person stares at the light output aperture and the product is isolated from DMX before
you connect it to a power supply unit or a battery pack.
You can hard-wire the SkyPanel to a building electrical installation. You can install a power plug that is suitable for the local power outlets on the power cable. Power outlets or external power switches that supply
the SkyPanel with power must be located near the external power supply unit and easily accessible so that
the PSU can easily be disconnected from power.
The external power supply unit of the SkyPanel requires a power input cable with a Neutrik® PowerCON®
True1 NAC3FX-W cable connector. Cable requirements are listed in section “Specification” on page 26.
ARRI offers power cables with PowerCON® cable connectors and different plugs or bare ends (see “Specification” on page 26).
The connector cable between the external power supply and the SkyPanel is available in different length
as an accessory. Use only ARRI connector cables (see “Specification” on page 26).
To Insert and Remove the PowerCON® Cable Connector
• Line up the raised key of the connector and the keyway of the input socket. Insert the cable connector
without force in the power input socket.
• Turn the cable connector a full quarter-turn clockwise to lock the cable connector.
• To unlock the cable connector, push the connector lock backwards and turn the cable connector counterclockwise. Pull the cable connector out of the power input socket.
22
To Insert and Remove the XLR Connector of the Connector Cable
To insert the cable connectors:
• Disconnect the external power supply unit from AC power.
• Line up the keyway of the female cable connector and the raised key of the 48 V DC power in socket of
the product (see Figure 3 on page 16). Insert the cable connector without force in the power in socket
until it locks.
• Line up the raised key of the male cable connector and the keyway of the power out socket of the power
supply unit. Insert the cable connector without force in the power out socket until it locks.
Power Through
The external power supply is equipped with a Neutrik® PowerCON® True1 power output socket to supply
other external power supplies for the SkyPanel from one power outlet. The voltage and frequency of the
power through is identical to the voltage and frequency of the power input.
Please find more information in the user manual of the power supply unit.
To Use a Battery Pack
To Power the SkyPanel
To remove the cable connectors:
• Press the connector lock and pull the cable connector out of the socket.
The SkyPanel can be powered independently from AC power with a battery pack. The battery pack must
meet the following requirements:
Output Voltage
23 - 36 V =
Battery operating temperature
68° F - 95° F (-20° C to +45° C)
Recommended minimum capacity
10 Ah
Power out connector
4-pin XLR Connector
Table 1: Specification of the battery pack
The product has a 4-pin XLR male connector for battery power and DMX data input. The pin-out is:
Pin
Assignment
1
GND
2
not connected
3
not connected
4
+23 - 36 V =
Table 2: Pin assignment of the battery input
NOTICE
Check that the pin-out of the battery pack matches the pin-out of the product. Wrong assigned pinouts damage the SkyPanel and / or the battery pack.
The SkyPanel switches off when the battery voltage drops below 22 V=. The product will be damaged, when the battery voltage exceeds 45 V=.
When a battery pack is discharged and switches off, please disconnect the battery pack before connecting a SkyPanel power supply unit.
Always follow the safety information for the battery pack. Use only battery packs that meet all requirements
listed above. The use of battery packs that do not fulfill the requirements damage the product and / or the
battery pack.
To Insert and Remove the 4-pin XLR Cable Connector
To insert the 4-pin XLR cable connector:
• The main switch of the battery pack must be turned off, if possible.
• Align the raised key of the cable connector with the keyway of the input socket (see Figure 3 on page 16).
Insert the cable connector without force in the input socket.
• The cable connector must lock. Repair or replace cable connectors that do not lock.
• To remove the 4-pin XLR cable connector:
• Switch of the battery pack, if possible.
• Press down the locking pin of the cable connector and remove the cable connector.
Tips for the use of Battery Packs
It is not possible to calculate the operating time of the battery pack exactly. The operating time is dependent
from age, state of charge, type of the battery pack and use of the SkyPanel.
23
23
DMX
DMX
To control the SkyPanel via DMX you need a DMX data link. The SkyPanel has 5-pin locking XLR sockets
for DMX / RDM data input and output. The default pin-out of both sockets is:
Pin 1 = Shield
Pin 2 = DMX Data - (cold)
Pin 3 = DMX Data + (hot)
Pin 4 = DMX Data - (cold)
Pin 5 = DMX Data + (hot)
Pins 4 and 5 are not used by the SkyPanel but are bridged between input and output sockets. These pins
can therefore be used as a pass-through connection for an additional data signal if required.
Do not overload the data link.You must not connect more than 32 SkyPanels per data link. Depending on
the channel requirements the address space of one data link (512 channels) may not be enough to control
all products of the installation. You may set more than one SkyPanel to identical DMX addresses to obtain
identical behavior. For independent control every SkyPanel needs to be assigned an individual address
range.
If you need to control more SkyPanels individual, you need to set up additional DMX data links.
Tips for a Reliable Data Transmission
• Use shielded twisted-pair cable designed for RS-485 devices or CAT 6 network cables. Standard microphone cable cannot transmit control data reliably over long runs. 24 AWG cable is suitable for runs up to
300 meters (1000 ft.). Heavier gauge cable and/or an amplifier is recommended for longer runs.
• To split the data link, use a DMX splitter. Use an RDM compatible splitter when you use the
RDM functionality.
• Install a DMX termination plug on the last product of every DMX data link. Terminate the DMX data link
on both ends, when you use the RDM functionality. Ask your system specialist for details.
To Connect the Data Link
• Connect the DMX data output from the controller to the data input (male XLR) of the first product on the
data link.
• Run the data link from the data output (female XLR) to the data input of the next product.
• Terminate the data link by connecting a 120 Ohm, 0.25 Watt resistor between the data 1 hot (+) and cold
(-) conductors (and between data 2 hot and cold if used) at the data output of the last product on the link.
24
Code
Error
Remedy
E.003
Controller over temperature.
STATUS LED lit up red.
Let the SkyPanel cool down. The STATUS indicator
changes to green when the SkyPanel has cooled
down. Turn the dimmer knob to „0“ or send an intensity value „0“ via DMX to activate the light engine
again.
E.004
Light engine over temperature
See E.003
E.005
Missing LED supply.
The LED power supply is faulty. Please contact the
ARRI service.
E.006
Calibration data of light engine
faulty or EEPROM error.
WARNING: Loss of calibration data. This error can
only be fixed by re-calibrating the light engine. Please
contact the ARRI service.
E.007
Invalid PWM value calculation
Notice: The SkyPanel can be used on. This message
is more a notification than an error.
E.008
Invalid values during calculation
See E.007
E.009
Invalid values during calculation
See E.007
E.010
Fan error. The fan speed deviates or the fan doesn’t run at all.
Set the fan to LOW or High Speed and see if it starts
rotating, in order to determine if there is an electrical
malfunction. All mechanical tests or repairs may only
be carried out by a trained service technician.
E.011
Fixture menu module not be
detected.
If the fixture menu is working, error E.011 can be
ignored. However, if the fixture menu remains dark (no
LED lights up) we recommend to contact the ARRI
service. They can then carry out detailed analyses.
E.012
Temperature sensor(s) are
defective or deviation within
NTC values too high.
One or more temperature sensors are defective or the
deviation within the individual NTCs or BNTCs
exceeds the variation tolerance of 12° C / 54° F.
E.013
Calibration data faulty.
WARNING: Loss of calibration data. Fixture needs to
be re-calibrated.
E.014
Watchdog error
Notice: The SkyPanel can be used on. This message
is more a notification than an error.
E.015
LED channel faulty
Notice: The SkyPanel can be used on. This message
is more a notification than an error.
E.016
Boost over temperature
Let the SkyPanel cool down. The STATUS indicator
changes to green when the SkyPanel has cooled
down. Turn the dimmer knob to „0“ or send an intensity value „0“ via DMX to activate the light engine
again.
E.017
Battery voltage too low
Battery voltage below 20.5 V. Change the battery pack
or switch to AC power.
E.018
PWM driver not found
Switch the SkyPanel off and on again. If the problem
persists, please contact the ARRI service.
E.019
Diffuser removed
The diffusor was removed. The protection circuit is
active (only RP-version).
E.020
Update with errors
This will be seen if the update process has detected
an error during the update. Please look at the error log
for more information to see which model or component had a problem with the update.
E.021
Flash init error. No filesystem
mounted.
This will happen if the flash disc has a problem with its
file system.
E.022
Missing Boost
The Boost board can not be identified during startup.
Switch the SkyPanel off and on again. If the problem
persists, please contact the ARRI service.
E.023
12V Missing
The 12V power is missing during startup. Please contact the ARRI service.
E.024
5V Missing
The 5V power is missing during startup. Please contact the ARRI service.
Error Codes
Error Codes
Table 3: Error codes
25
25
Specification
Specification
Physical, SkyPanel S30
Depth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133 mm (5.2 in.)
Wide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 507 mm (19.9 in.)
Height . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 347 mm (13.6 in., w/o stirrup)
Weight (w/o accessories) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 kg (17.6 lbs), 9 kg (20 lbs)
Physical, SkyPanel S60
Depth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133 mm (5.2 in.)
Wide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 813 mm (32.0 in.)
Height . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 347 mm (13.6 in., w/o stirrup)
Weight (w/o accessories) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 kg (26.5 lbs), 13 kg (28.7 lbs)
Physical, SkyPanel S120
Depth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133 mm (5.2 in.)
Wide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1467 mm (57.8 in.), man.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1439 mm (56.7 in.), P.O.
Height . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 347 mm (13.6 in., w/o stirrup)
Weight (w/o accessories, with PSU) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 kg (35.3 lbs), man.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 kg (44.1 lbs), P.O.
Physical, external power supply unit
Depth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .383 mm (15 in.)
Wide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90 mm (3.5 in., S30), 190 mm (7.5 in., S60 / S120)
Height . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116 mm (4.6 in., S30), 90 mm (3.5 in., S60 / S120)
Weight. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2,2 kg (4.8 lbs, S30), 3,7 kg (8.2 lbs, S60 / S120)
Light source
Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ARRI LED Light Engine
Typ. LED lifetime L70 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50.000 h
White light . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.800 K - 10.000 K (SkyPanel-C)
White light . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Color temperature defined by remote phosphor panels (SkyPanel-RP
Colored light . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RGBW color mixing (SkyPanel-C)
Color rendition index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . typ. CRI >94
Green - Magenta point . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +/- 1 (full green to full magenta, only SkyPanel-C)
Optical path
Type . . . . . . . . . . . . . . . . . . . . . . . soft light with diffuser plate (SkyPanel-C) or remote phospor panel (SkyPanel-RP)
Light aperture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .355 x 300 mm (14 x 11.8 in, S30)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 645 x 300 mm (25.4 x 11.8 in, S60)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1290 x 300 mm (50.8 x 11.8 in, S120)
Dynamic functions
Dimmer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . electronic, 0 - 100%
Color mixing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RGBW color mixing (Hue and saturation, only SkyPanel-C)
26
Channels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-21 channels, depending on type and mode
Setting and addressing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Fixture menu, ALSM
DMX compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ESTA DMX512A
RDM compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ESTA DMX512A
Art-Net. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Version 4
sACN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ANSI E1.31
Firmware update . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . USB interface, network, ALSM
Specification
Control and Programming
Construction
Color . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Blue / silver or black
Housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Composite and aluminum
Protection rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IP 20
Protection class. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .III
Installation
Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 mm spigot or 16 mm / 28 mm combo pin
Orientation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . any
Min. clearance around fixture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.5 m (19.7 in)
Min. view distance to light aperture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0,5 m (39.4 in)
Connectors
DC power input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Neutrik® locking 3-pin XLR
Battery pack connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Neutrik® locking 4-pin XLR
DMX / RDM in / thru . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Neutrik® locking 5-pin XLR
Ethernet connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Neutrik® RJ45 EtherCON connector
USB interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .USB-A
Electrical
SkyPanel
Power input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 V =
Max. cable length between PSU and luminaire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 m (49 ft.)
External power supply unit
Power input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110 - 240 V ~, 50 / 60 Hz (nom.)
Power output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 V =
Power supply. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Auto-sensing switching-mode power supply
Typical power
230 V, 50 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210 W nom. (SkyPanel S30)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 420 W nom. (SkyPanel S60)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 400 W nom. (SkyPanel S120)
cos  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . > 0,9
Measurements made at nominal voltage with all LEDs at full intensity. Allow for a deviation of +/- 10%
Noise emission
Ambient temperature = 35° C (95° F) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . < 20dB(A)
Ambient temperature = 45° C (113° F) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . < 30dB(A)
Thermal
Minimum ambient temperature (ta) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -20° C (-4° F)
Maximum ambient temperature (ta) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45° C (113° F)
Cooling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Silent, temperature-controlled fan cooling
27
27
Specification
SkyPanel S120-C: RISK GROUP 0 - No Risk
No photobiological hazard.
SkyPanel S30-C/RP and S60-C/RP: RISK GROUP 1
No photobiological hazard under normal behavioral limitations.
Approvals
EU Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EN / IEC 60598-2-17
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EN / IEC 60598-1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EN / IEC 62471
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EN / IEC 62493
EU EMC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EN 55015
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EN / IEC 61000-3-2
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EN / IEC 61000-3-3
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EN / IEC 61547
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CISPR 15
US Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UL1573
US EMC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FCC CFR 47 Part 2
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FCC CFR 47 Part 15
Canada Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CAN/CSA C22.2 No. 166
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .CAN/CSA C22.2 No. 9.0
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CAN/CSA C22.2 N0. 9.0S1
Canada EMC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ICES-003
Japan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .PSE
28
All versions include
Power supply unit (PSU)
Rail mount adapter for SkyPanel PSU (not with Center Mount)
Standard diffusion panel (only C-Version)
Specification
Order Information
Manual and Center Mount versions include additional
Yoke with 16 mm / 28 mm combo pin (manual version)
DC header cable 48 V= (XLR 3-pin), l = 3 m (10 ft)
PowerCON TRUE1 mains cable, l = 3 m (10ft) with mains connector
Center mount yoke (Center Mount version)
P.O. versions include additional
Steel yoke with 28 mm junior pin
DC header cable 48 V= (XLR 3-pin), l = 1 m (3.3 ft)
PowerCON TRUE1 mains cable, l = 3 m (10ft) with bare ends
Pole operation for pan and tilt
ARRI SkyPanel S30-C
S30-C, MAN, blue/silver, Edison - Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .L0.0007711
S30-C, MAN, blue/silver, Schuko - Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .L0.0007712
S30-C, MAN, blue/silver, China - Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .L0.0007713
S30-C, MAN, blue/silver, PSE Japan - Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .L0.0012394
S30-C, P.O., blue/silver, bare ends - Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .L0.0007714
S30-C, P.O., black, bare ends - set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .L0.0007716
ARRI SkyPanel S30-RP
S30-RP, MAN, blue/silver, 3.200 K, Edison - Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .L0.0007717
S30-RP, MAN, blue/silver, 3.200 K, Schuko- Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .L0.0007718
S30-RP, MAN, blue/silver,3.200 K, China - Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .L0.0007720
S30-RP, MAN, blue/silver, 3.200 K, PSE Japan - Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .L0.0012395
S30-RP, P.O., blue/silver,3.200 K, bare ends - Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .L0.0007721
S30-RP, P.O., black,3.200 K, bare ends - Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .L0.0007722
S30-RP, MAN, blue/silver,5.600 K, Edison - Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .L0.0007723
S30-RP, MAN, blue/silver,5.600 K, Schuko- Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .L0.0007724
S30-RP, MAN, blue/silver,5.600 K, China - Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .L0.0007725
S30-RP, MAN, blue/silver, 5.600 K, PSE Japan - Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .L0.0012396
S30-RP, P.O., blue/silver,5.600 K, bare ends - Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .L0.0007726
S30-RP, P.O., black,5.600 K, bare ends - Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .L0.0007727
ARRI SkyPanel S60-C
S60-C, MAN, blue/silver, Edison - Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .L0.0007063
S60-C, MAN, blue/silver, Schuko - Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .L0.0007064
S60-C, MAN, blue/silver, China- Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .L0.0007065
S60-C, MAN, blue/silver, PSE Japan - Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .L0.0012397
S60-C, P.O., blue/silver, bare ends - Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .L0.0007066
S60-C, P.O., black, bare ends - Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .L0.0007067
ARRI SkyPanel S60-RP
S60-RP, MAN, blue/silver, 3.200 K, Edison - Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .L0.0007068
S60-RP, MAN, blue/silver, 3.200 K, Schuko - Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .L0.0007069
S60-RP, MAN, blue/silver,3.200 K, China - Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .L0.0007070
S60-RP, MAN, blue/silver,3.200 K, PSE Japan - Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .L0.0012399
S60-RP, P.O., blue/silver,3.200 K, bare ends - Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .L0.0007071
S60-RP, P.O., black,3.200 K, bare ends - Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .L0.0007072
S60-RP, MAN, blue/silver,5.600 K, Edison - Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .L0.0007073
S60-RP, MAN, blue/silver,5.600 K, Schuko - Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .L0.0007074
S60-RP, MAN, blue/silver,5.600 K, China - Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .L0.0007075
S60-RP, MAN, blue/silver,5.600 K, PSE Japan - Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .L0.0012400
S60-RP, P.O., blue/silver,5.600 K, bare ends - Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .L0.0007076
S60-RP, P.O., black,5.600 K, bare ends - Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .L0.0007077
29
29
Specification
ARRI SkyPanel S120-C
S120-C, MAN, blue/silver, Edison - Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . L0.0012956
S120-C, MAN, blue/silver, Schuko - Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . L0.0012954
S120-C, MAN, blue/silver, China- Set. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . L0.0012957
S120-C, MAN, blue/silver, PSE, Japan - Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . L0.0012955
S120-C, Center Mount, blue/silver, Edison - Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . L0.0012950
S120-C, Center Mount, blue/silver, Schuko - Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . L0.0012948
S120-C, Center Mount, blue/silver, China - Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . L0.0012951
S120-C, Center Mount, blue/silver, PSE, Japan - Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . L0.0012949
S120-C, P.O., blue/silver, bare ends - Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . L0.0012953
S120-C, P.O., black, bare ends - Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . L0.0012952
S120-C, blue/silver, w/o cables and stirrup. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . L1.0009652
S120-C, black, w/o cables and stirrup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . L1.0009653
Accessories for all models (S30-C, S30-RP, S60-C, S60-RP)
PSU S30, blue/silver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . L2.0007735
PSU S30, black. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . L2.0007886
PSU S60 / S120, blue/silver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . L2.0012491
PSU S60 / S120, black . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . L2.0012492
Mains cable, powerCON TRUE1, l = 3 m, Schuko . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . L2.0007516
Mains cable, powerCON TRUE1, l = 3 m, Edison . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . L2.0007515
Mains cable, powerCON TRUE1, l = 3 m, China . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . L2.0007514
Mains cable, powerCON TRUE1, l = 3 m, bare ends . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . L2.0005974
DC cable 48 V=, XLR 3-pol., l = 0,5 m . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . L2.0007492
DC cable 48 V=, XLR 3-pol., l = 1 m. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . L2.0007491
DC cable 48 V=, XLR 3-pol., l = 3 m. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . L2.0007493
DC cable 48 V=, XLR 3-pol., l = 10 m. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . L2.0007494
DC cable 48 V=, XLR 3-pol., l = 15 m. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . L2.0007860
Battery DC cable, XLR 4-pin, l = 0,5 m . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . L2.0008499
Battery DC cable, XLR 4-pin, l = 3 m . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . L2.0008500
Battery adapter plate for Anton/Bauer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . L2.0008071
V-Mount Battery adapter plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . L2.0008070
Center mount yoke . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . L2.0008078
Fixed center mount yoke. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . L2.0008080
Rail mount adapter for SkyPanel PSU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . L2.0008082
Super clamp adapter for SkyPanel PSU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . L2.0006921
Accessories
Please find a detailed overview of all accessories available in the „SkyPanel Accessories Guide“ on the ARRI web site.
Specification subject to change without notice. For the latest product specification including photometric data, see
www.arri.com
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference
to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in
which case the user will be required to correct the interference at his own expense.
30
33
33
Specification