1
Industrial Managed Switches / Industrial PoE Series
IPGS-3208MGSFP
8 10/100/1000T + 2 1.25G/2.5G SFP L2+ w/8 PoE at/af Industrial
Managed Switch w/ Enhanced G.8032 Ring; Optional 12V input model
 Multi-rate SFP cage support with 1.25G or 2.5G Mbps SFP
 Support IEEE802.3at/af up to 30W per port
 PoE management incl. Detection and Scheduling
 Enhanced G.8032 ring protection < 20ms with basic mode,
enhanced mode, train mode** and auto** mode; Enhanced
G.8032 ring covers multicast packets; MSTP 8MSTI/RSTP
 Miss-wiring avoidance & Repowered auto ring restore (node
failure protection)
 User friendly UI, including auto topology drawing and DDM
threshold monitoring with dB values**; Complete CLI
 Support LACP link aggregation, VLAN, QoS, IGMP v3/router port, GVRP, DHCP server
& client, DHCP Option 82 relay / server**, TACAS+, ACL, SSH/SSL, IPv6, SMS
 Dual 9.5V~57VDC input(12V model) or Dual 48V DC input(48V model)
 USB port* and N-key** for backup, restore the configuration file and upgrade firmware
 Optional Environmental monitoring function to display inside switch info incl.
temperature, voltage, current, power consumption
OVERVIEW
Lantech IPGS-3208MGSFP is a high performance L2+ all
Gigabit switch with 8 10/100/1000T + 2x 1.25G/2.5G selectable
Loop protection; Auto ring repowered restore; Alert by
multi-Giga- rate SFP w/8 PoE 802.3af/at Injectors which
email,trap,SMS
provides L2 wire speed and advanced security function for
The IPGS-3208MGSFP also embedded several features for
network aggregation deployment. It delivers ITU G.8032
stronger and reliable network protection in an easy and intuitive
enhanced ring recovery less than 20ms for single ring,
way. When the pre-set ring configuration failed or looped by
comprehensive QoS, VLAN, GVRP advanced security
miss-wiring, Lantech IPGS-3208MGSFP is able to alert with the
SSH/SSL, TACAS+, ACL, IGMPv1/v2/v3/router port, DHCP
LED indicator and send out an email, trap or a SMS text.
server/relay , jumbo frame which are important features
Repowered auto ring restore function (node failure protection)
required in mid and large network. It also supports Cisco
ensures the switches in a ring to survive after power breakout is
Discovery Protocol (CDP) and LLDP for Ciscoworks to detect
back. The status can be shown in NMS when each switch is
the switch info and to be shown on L2 map topology.
back. This feature prevents the broken ring and keep ring alive
without any re-configuration needed. Loop protection is also
PoE at/af up to 8 Giga Ports with detection and scheduling
available to prevent the generation of broadcast storm when a
Lantech IPGS-3208MGSFP supports advanced PoE
dumb switch is inserted in a closed loop connection.
management including PoE detection and scheduling. PoE
detection can detect if the connected PD is hanged then restart
User friendly UI; Auto topology drawing; DMI for dB value
the PD; PoE scheduling is to allow pre-set power feeding
The user friendly UI, innovative auto topology drawing and
schedule upon routine time table. Each PoE ports can be
topology demo makes IPGS-3208MGSFP much easier to get
Enabled/disabled, get the voltage, current, Watt, and
hands-on. The switch also equips the RTC (real time clock)
temperature info displayed on WebUI.
which can keep track of time always. The IPGS-3208MGSFP
supports DMI interface that can correspond with DDM SFPs
Datasheet Version 1.6
www.lantechcom.tw | info@lantechcom.tw
2
Industrial Managed Switches / Industrial PoE Series
(Digital diagnostic monitor) to display the five parameters in
CPU is found dead.
Lantech’s UI, including optical output power, input power,
temperature, laser bias current and transceiver supply
voltage***. The TX power/RX power raw data is automatically
converted to dB values for installer, making it easier to calculate
the fiber distance. The complete CLI enables professional
engineer to configure setting by command line.
Enhanced G.8032 Ring < 20ms covering multicast packets
USB port* & N-key** for back up, restore configuration and
upgrade firmware
The built-in USB port* can upload/download the firmware
through USB dongle for switch replacement.
With N-key**, the configuration file can be mass auto backup,
editable restored and auto upgrade firmware for easy
maintenance.
for single ring recovery;
Enhanced/basic/auto**/train**mode; MSTP/RSTP
2DI / 2DO relay to alarm and email/trap
Lantech IPGS-3208MGSP features enhanced G.8032 ring
Featured with relay contact alarm function, the
which can be self-healed in less than 20ms for single ring
IPGS-3208MGSFP is able to connect with alarm system in case
topology protection covering Multicast packets. It also supports
of power failure and port disconnection.
various ring topologies that covers double ring, multi-chain
(under enhanced ring), train ring**, basic ring by easy setup
Relay alarm and email/trap/SMS alerting
than others.
Featured with relay contact alarm function, the
The innovative auto-Ring** configurator (auto
mode) can calculate owner and neighbor in one step. It
IPGS-3208MGSFP is able to connect with alarm system in case
supports MSTP that allows RSTP over Vlan for redundant links
of power failure and port disconnection. In case of such event, it
with 8 MSTI.
will send out email, SMS, trap alerting to predefined users.
DHCP server / client ; DHCP option 82 relay, port
Dual 12V~48V input with boost technology to 54V PoE
based**/Mac based DHCP**
output for 12V model, PoE budget 80W
It supports the standard DHCP server/client as well as DHCP
Lantech IPGS-3208MGSFP-12V is designed with dual input
option 82 relay.
power at 9.5V~57VDC while IPGS-3208MGSFP-48V allows
The optional port based DHCP distribution
can offer the same IP address on port base where there is need
44~57VDC input. The PoE budget for 12V input is 80W and 24V
to replace the new device connecting to Lantech switches to
input is 120W.
avoid any network disruption. The optional DHCP Option 82
server offers the convenience of policy setting on the switch.
Optional environmental monitoring for inside switch info
Mac based DHCP server** function binds a fixed IP address
The optional environmental monitoring can detect switch overall
and a client Mac address to include dumb switches in DHCP
temperature, voltage, current and power consumption where
network.
can send the SNMP traps, email and SMS alert when abnormal.
Optional QoS by VLAN for legacy device
High reliability and extended working temperature
QoS by VLAN can allow switch to tag QoS by VLAN regardless
Lantech IPGS-3208MGSFP provides ±2000V EFT and ±6000V
the devices acknowledge QoS or not in which greatly enhance
contact ESD protection, which can reduce unstable situation
the bandwidth management in a network.
caused by power line and Ethernet. It has high reliability and
robustness coping with extensive EMI/RFI phenomenon,
Exported configuration text file; Factory reset button; CPU
environmental vibration and shocks usually found in Automation,
watchdog
transportation, surveillance, Wireless backhaul, Semi-conductor
The configuration file of Lantech IPGS-3208MGSFP can be
factory and assembly lines.
exported in text file so that it can be edited and configured back
to switch with ease for mass deployment.
Factory reset button
can restore the setting back to factory default and built-in
The -E model can be used in extreme environments with an
operating temperature range of -40°C to 75°C.
watchdog design can automatically reboot the switch when
FEATURES & BENEFITS

8 10/100/1000T + 2 1.25G/2.5G selectable SFP w/8

Back-plane (Switching Fabric): 26Gbps
PoE 802.3af/at Injectors (Total 10 Ports Switch)

16K MAC address table

Support 10K bytes jumbo frames


Embedded 8 PoE Injectors IEEE802.3af/at function
DDM to support SFP diagnostic function***

to feed power up to 30W per port for active
values for TX power/RX power, making it easier
operation


to measure the fiber distance
Dual 9.5V~57VDC power input for 12V model with

10KB Jumbo frame supported on all ports
PoE budget 80W at 12V input, 120W at 24V input

User friendly UI, auto topology drawing, topology
Dual 44V~57VDC power input for 48V model with
PoE budget 120W

Automatically convert the raw data into dB
demo, complete CLI for professional setting

Enhanced G.8032 Ring protection in 20ms < 256
PoE management including PoE detection and
switches(single ring)
scheduling for PD (power devices)

Support single ring, double ring, multi-chain
topology with easy setup than ever
Datasheet Version 1.6
www.lantechcom.tw | info@lantechcom.tw
3
Industrial Managed Switches / Industrial PoE Series

Auto ring configuration**

Basic mode compatible with 3rd party ERPS

Covers multi-cast and data packets

Provides EFT protection ±2000 VDC for power line.

Supports ±6000 VDC ESD contact protection

Built-in RTC (Real Time Clock) to keep track of time

Supports IEEE 802.1p Class of Service, per port
provides 8 priority queues Port base, Tag Base and


editable restoration and auto firmware upgrade

System Event Log, SMTP Email alert, SMS mobile
(text) and SNMP Trap for alarm support; 32 RMON
counters

Security
Type of Service Priority

SSL/SSH/ L2&L3
IEEE 802.1d STP, IEEE 802.1w RSTP,802.1s MSTP

Port Security: MAC address
entries/Filter/MAC-Port binding
4K 802.1Q VLAN, Port based VLAN, GVRP, QoS by

VLAN**



prevent unauthorized intruder.

Management access control with priority
can be viewed via Web/ Console/ LantechTM

TACAS+
InstaConfig**/ LantechTM InstaView**

ACL
DHCP server / client; DHCP Option 82 relay/ server**;

Login Security: IEEE802.1X/RADIUS
Mac based DHCP**; Port based DHCP**

HTTPS for secure access to the web interface
Bandwidth Control


Ingress packet filter and egress rate limit

Broadcast/multicast packet filter control
Relay alarm output system events

Miss-wiring avoidance
LED indicator

Email, traps, or SMS notification
ports for IP surveillance application

IGMPv1,v2,v3 with Query mode for multimedia

Factory reset button to restore setting to factory
default

The status can be shown in NMS when each
switch is back
InstaConfig** for multiple upgrade
Configuration backup and restoration
Optional environmental monitoring for system input
voltage, current, ambient temperature

TFTP/HTTP firmware upgrade; LantechTM

Multicast static forwarding for non- IGMP camera to

Ensure the switches in a ring to survive after
power breakout is back

flow (MVR) with multicast packets binding with
in ring and for reversed multicast video flow
Repowered auto ring restore

Static multicast forwarding forward reversed IGMP
prevent flooding; IGMP router port to assign query



IP Security: IP address security management to
Supports IEEE 802.1ab LLDP, Cisco CDP; LLDP info


USB port* to upload/download firmware by USB
dongle

VLAN redundancy with 8 MSTI

N-key** for mass configuration auto-backup,
Watchdog design to auto reboot switch CPU is
found dead

IP30 metal housing with DIN rail and Wall-mount**
design
Supports text configuration file for system quick
installation
DIMENSIONS (unit=mm)
/// The USB port on this model will be future released ///
Datasheet Version 1.6
www.lantechcom.tw | info@lantechcom.tw
4
Industrial Managed Switches / Industrial PoE Series
SPECIFICATION
Hardware Specification
Standards
IEEE802.3 10Base-T Ethernet
IEEE802.3u 100Base-TX
IEEE802.3ab 1000Base-T Ethernet
IEEE802.3z Gigabit fiber
IEEE802.3x Flow Control and Back Pressure
IEEE802.3ad Port trunk with LACP
IEEE802.1d Spanning Tree
IEEE802.1w Rapid Spanning Tree
IEEE802.1s Multiple Spanning Tree
IEEE802.3ad Link Aggregation Control Protocol
(LACP)
IEEE802.1AB Link Layer Discovery Protocol (LLDP)
IEEE802.1X User Authentication (Radius)
IEEE802.1p Class of Service
IEEE802.1Q VLAN Tag
IEEE802.3at/af Power over Ethernet
80W at 12V input; 120W at 24V input(12V model)
PoE pin assignment
RJ-45 port # 1~#8 support IEEE 802.3at/af End-point,
Alternative A mode. Per port provides up to 30W
Positive (VCC+): RJ-45 pin 1,2.
Negative (VCC-): RJ-45 pin 3,6.
Power
Consumption
10W
Case Dimension
IP-30, 74 (W) x 114 (D) x 152 (H) mm
Weight
900 g
Installation
DIN Rail and Wall Mount** Design
EMI & EMS
FCC Class A,
CE EN55022 Class A, CE EN55024, CE
EN61000-4-2, CE EN61000-4-3, CE EN61000-4-4,
CE EN61000-4-5 ED3, CE EN61000-4-6, CE
N61000-4-8, EN61000-4-11
Stability Testing
IEC60068-2-32 (Free fall), IEC60068-2-27 (Shock),
IEC60068-2-6 (Vibration)
Switch Architecture
Back-plane (Switching Fabric): 26Gbps
MTBF
NA
Transfer Rate
14,880pps for Ethernet port
148,800pps for Fast Ethernet port
1,488,000pps for Gigabit Fiber / Gigabit Ethernet port
Warranty
5 years
Mac Address
16K MAC address table
Jumbo frame
10KB on all ports
Connectors
10/100/1000T: 8 x ports RJ-45 with Auto MDI/MDI-X
function
SFP port: 2 x 2.5G/1.25G selectable cage by
software with DDMI supported
RS-232 connector: RJ-45 type; USB x 1*
Power & P-Fail connector: 1 x 6-pole terminal block
Network Cable
10Base-T: 2-pair UTP/STP Cat. 3, 4, 5/ 5E/ 6 cable
EIA/TIA-568 100-ohm (100m)
100Base-TX: 2-pair UTP/STP Cat. 5/ 5E/ 6 cable
EIA/TIA-568 100-ohm (100m)
1000Base-TX: 2-pair UTP/STP Cat. 5/ 5E/ 6 cable
Software Specification
Management
SNMP v1 v2c, v3/ Web/Telnet/CLI
SNMP MIB
RFC 1215 Traps MIB,
RFC 1213 MIBII
RFC 1158 MIBII
RFC 1157 SNMP MIB,
RFC 1493 Bridge MIB,
RFC 1573 IF MIB
RFC 2674 VLAN MIB,
Partial RFC 1643 EtherLike,
Partial RFC 1757 RMON,
RFC 2674 Q-Bridge MIB; Bridge MIB,
RFC 2790 Host Resource MIB
LLDP MIB*
RSTP MIB*
EIA/TIA-568 100-ohm (100m)
Optical Cable
1.25Gbps:
Multi mode: 0 to 550 m, 850 nm (50/125 μm); 0 to 2
km, 1310 nm (50/125 μm)
Single mode: 0 to 10 km/ 30 km/ 40 km, 1310 nm
(9/125 μm); 0 to 50 km/ 60 km/ 80km/ 120 km, 1550
nm (9/125 μm)
2.5Gbps
Multi mode: 0 to 550 m, 850 nm (50/125 μm);
Single mode: 0 to 10 km/ 30 km/ 40 km, 1310 nm
(9/125 μm); 0 to 50 km/ 60 km/ 80km/ 120 km, 1550
nm (9/125 μm)
WDM 1.25Gbps:
Single mode: 0 to 10 km/ 20 km/ 40 km/ 60 km, 1310
nm (9/125 μm); 0 to 80 km, 1490 nm (9/125 μm); 0 to
10 km/ 20 km/ 40 km/ 60 km/ 80 km, 1550 nm (9/125
μm)
WDM 2.5Gbps
Single mode: 0 to 10 km/ 20 km/ 40 km/ 60 km, 1310
nm (9/125 μm); 0 to 80 km, 1490 nm (9/125 μm); 0 to
10 km/ 20 km/ 40 km/ 60 km/ 80 km, 1550 nm (9/125
μm)
Protocol
CSMA/CD
LED
Per unit: Power 1 (Green), Power 2 (Green), P-Fail
(Red); RM(Green)
Ethernet port: Link/Activity (Green), Speed (Amber);
PoE : Link/Act (Green); Mini-GBIC: Link/Activity
(Green)
Operating Humidity
5% ~ 95% (Non-condensing)
Operating
Temperature
-20°C~60°C / -4°F~140°F (Standard model)
-40°C~75°C / -40°F~167°F(-E model)
Storage
Temperature
-40°C~85°C / -40°F~185°F
Power Supply
44~57VDC(48V model); 9.5V~57VDC(12V model)
PoE Budget
240W for 44~57V input(48V model)
(54V input is recommended for 802.3at 30W
applications)
Private MIB
Enhanced G.8032
ring
Support ITU G.8032 v2/2012 for single ring protection
in less than 20ms for self-heal recovery;
Support Enhanced mode, basic mode; auto mode**
and train mode**
Support double ring, multi-chain ring, etc.
Covers multicast and data packets
PoE Management
1.
2.
PoE Detection to check if PD is hang up
then restart the PD
PoE Scheduling to On/OFF PD upon routine
time table
Per Port PoE
Status
On/ Off, voltage, current, watts, temperature
User friendly UI





Auto topology drawing
Topology demo
Auto configuration for G.8032(auto mode)**
for single ring
DDM threshold monitoring with dB values***
Complete CLI for professional setting
Port Trunk with
LACP
LACP Port Trunk: 8 Trunk groups/Maximum 10 trunk
members
LLDP
Supports LLDP to allow switch to advise its
identification and capability on the LAN
CDP
Cisco Discovery Protocol for topology mapping
VLAN
Port Based VLAN
IEEE 802.1Q Tag VLAN (256 entries)/ VLAN ID (Up
to 4K, VLAN ID can be assigned from 1 to 4096.),
GVRP, QoS by VLAN**
IPv6/4
Present
RSTP/MSTP
Supports IEEE802.1d Spanning Tree and
IEEE802.1w Rapid Spanning Tree, IEEE802.1s
Multiple Spanning Tree with 8 MSTI
Quality of Service
The quality of service determined by port, Tag and
IPv4 Type of service, IPv4 Differentiated Services
Code Points - DSCP
Class of Service
Support IEEE802.1p class of service, per port
Datasheet Version 1.6
www.lantechcom.tw | info@lantechcom.tw
5
Industrial Managed Switches / Industrial PoE Series
provides 8 priority queues
Alarm Relay current carry ability: 1A @ DC24V
IP Security
Supports 10 IP addresses that have permission to
access the switch management and to prevent
unauthorized intruder.
Protection



Login Security
Supports IEEE802.1X Authentication/RADIUS
SNMP Trap
Port Mirror
Support 3 mirroring types: “RX, TX and Both packet”
Network Security
Support 10 IP addresses that have permission to
Up to 10 trap stations; trap types including:

Device cold start

Authorization failure
access the switch management and to prevent
unauthorized intruder.
802.1X access control for port based and MAC based
authentication/MAC-Port binding
Management access control with priority
TACAS+
ACL
SSL/ SSH for Management
HTTPS for secure access to the web interface
IGMP
Support IGMP snooping v1,v2,v3; Supports IGMP
static route; 256 multicast groups; IGMP router port ;
IGMP query; GMRP**
Miss-wiring avoidance
Repowered auto ring restore
Loop protection





Port link up/link down
Topology change(ITU ring)
PoE ping failure
Power failure
Environmental abnormal**
DHCP
Provide DHCP client/ DHCP Server/ DHCP option 82
relay /DHCP option82 server** ; Mac based DHCP**;
Port based DHCP**
DNS
Provide DNS Client feature and support Primary and
Secondary DNS server.
SNTP
Supports SNTP to synchronize system clock in
Internet
MVR
Static multicast forwarding forward reversed IGMP
flow (MVR) with multicast packets binding with ports
for IP surveillance application
Environmental
Monitoring**
System status for input voltage, current, consumption
and ambient temperature to be shown in GUI and
sent alerting if any abnormal status(-M models)
Bandwidth Control
Support ingress packet filter and egress packet limit.
The egress rate control supports all of packet type.
Ingress filter packet type combination rules are
Broadcast/Multicast/Flooded Unicast packet,
Broadcast/Multicast packet, Broadcast packet only
and all types of packet.
Firmware Update
Supports TFTP firmware update, TFTP backup and
restore; HTTP firmware upgrade; LantechTM
InstaConfig** for multiple upgrade
Supports text configuration file for system quick
installation
N-key** for mass firmware auto-backup, editable
restoration and auto upgrade
USB port* to upload/download firmware by USB
dongle
The packet filter rate can be set an accurate value
through the pull-down menu for the ingress packet
filter and the egress packet limit.
RTC
Built-in Real Time Clock to keep track of time always
Flow Control
Supports Flow Control for Full-duplex and Back
Pressure for Half-duplex
System Log
Supports System log record and remote system log
server
SMTP/Text SMS
Supports SMTP Server and 8 e-mail accounts for
receiving event alert; can send SMS text alert via
Configuration
upload and
download
IfAlias
Each port allows an alphabetic string of 128-byte
assigned as its own unique name via the SNMP or
CLI interface
*Future Release
**Optional
***Optional DDM SFP required
mobile
Relay Alarm
Provides one relay output for port breakdown, power
fail and alarm.
ORDERING INFOMATION

IPGS-3208MGSFP-48V….……….. …..…....P/N: 8350-990
8 10/100/1000T + 2 2.5G/1.25Gbps SFP w/8 PoE Mode A 802.3at/af 30W Managed Industrial Switch; dual 44~57VDC input;
-20°C to 60°C

IPGS-3208MGSFP-48V-E………….….........P/N: 8350-991
8 10/100/1000T + 2 2.5G/1.25Gbps SFP w/8 .PoE Mode A 802.3at/af 30W Managed Industrial Switch; dual 44~57VDC input;
-40°C to 75°C

IPGS-3208MGSFP-12V….……..…... .….....P/N: 8350-992
8 10/100/1000T + 2 2.5G/1.25Gbps SFP w/8 PoE Mode A 802.3at/af 30W Managed Industrial Switch, dual 9.5V~57VDC input;
-20°C to 60°C

IPGS-3208MGSFP-12V-E…………….…......P/N: 8350-993
8 10/100/1000T + 2 2.5G/1.25Gbps SFP w/8 PoE Mode A 802.3at/af 30W Managed Industrial Switch, dual 9.5V~57VDC input,
-40°C to 75°C

IPGS-3208MGSFP-M-48V….………… .…....P/N: 8350-9902
8 10/100/1000T + 2 2.5G/1.25Gbps SFP w/8 PoE Mode A 802.3at/af 30W Managed Industrial Switch w/Environmental
monitoring; dual 44~57VDC input; -20°C to 60°C

IPGS-3208MGSFP-M-48V-E……….….........P/N: 8350-9912
8 10/100/1000T + 2 2.5G/1.25Gbps SFP w/8 .PoE Mode A 802.3at/af 30W Managed Industrial Switch w/Environmental
monitoring; dual 44~57VDC input; -40°C to 75°C

IPGS-3208MGSFP-M-12V….………... .….....P/N: 8350-9922
8 10/100/1000T + 2 2.5G/1.25Gbps SFP w/8 PoE Mode A 802.3at/af 30W Managed Industrial Switch w/Environmental
monitoring, dual 9.5V~57VDC input; -20°C to 60°C

IPGS-3208MGSFP-M-12V-E………….…......P/N: 8350-9932
8 10/100/1000T + 2 2.5G/1.25Gbps SFP w/8 PoE Mode A 802.3at/af 30W Managed Industrial Switch w/Environmental
monitoring, dual 9.5V~57VDC input, -40°C to 75°C

N-key Configurator………..……………........P/N: 8850-100
RJ45 connector dongle for firmware upgrade, auto/editable configuration backup and restoration; -20°C to 60C
Datasheet Version 1.6
www.lantechcom.tw | info@lantechcom.tw
6
Industrial Managed Switches / Industrial PoE Series
OPTIONAL ACCESSORIES
48~54VDC DIN Rail Power for 802.3at Applications
 AD1240-48S
48~57VDC, 4.3A, Wide AC Input, Build-in fan Cooled, DIN Rail or Wall Mounted, RoHS, Operating Temp. -20°C~50°C
(ambient, derating each output at 2.5% per degree from 50°C ~ 70°C)
 AD1360-48S
48~57VDC, 6.5A, Wide AC Input, Build-in fan Cooled, DIN Rail or Wall Mounted, RoHS, Operating Temp. -20°C~50°C
(ambient, derating each output at 2.5% per degree from 50°C ~ 70°C)
 AD1500-48S
48~57VDC, 9A, Wide AC Input, Build-in fan Cooled, DIN Rail or Wall Mounted, RoHS, Operating Temp. -20°C~50°C
(ambient, derating each output at 2.5% per degree from 50°C ~ 70°C)
Mini GBIC (SFP)
 8330-162X
 8330-163X
 8330-165X
 8340-0591
 8330-166
 8330-169
 8330-167
 8330-170
 8330-168
 8330-188
 8330-189
MINI GBIC 1000SX (LC/0.5km) Transceiver
MINI GBIC 1000SX2 (LC/2km) Transceiver
MINI GBIC 1000LX (LC/10km) Transceiver
MINI GBIC 1000LHX (LC/40km) Transceiver
MINI GBIC 1000XD (LC/50km) Transceiver
MINI GBIC 1000XD (LC/60km) Transceiver
MINI GBIC 1000ZX (LC/80km) Transceiver
MINI GBIC 1000EZX (120km) Transceiver
MINI GBIC 1000T (100m) Transceiver
LTSFP-1000BX-10KM Transceiver (WDM 1310)
LTSFP-1000BX-10KM Transceiver (WDM 1550)
 8330-186
 8330-187
 8330-180
 8330-182
 8330-181
 8330-183
 8330-184
 8330-185
 8330-262
 8330-263
 8330-265
LTSFP-1000BX-20KM Transceiver (WDM 1310)
LTSFP-1000BX-20KM Transceiver (WDM 1550)
LTSFP-1000BX-40KM Transceiver (WDM 1310)
LTSFP-1000BX-40KM Transceiver (WDM 1550)
LTSFP-1000BX-60KM Transceiver (WDM 1310)
LTSFP-1000BX-60KM Transceiver (WDM 1550)
LTSFP-1000BX-80KM Transceiver (WDM 1490)
LTSFP-1000BX-80KM Transceiver (WDM 1550)
MINI GBIC 2.5G 850nm VCSEL (LC/0.3km) Transceiver
MINI GBIC 2.5G 1310nm FP (LC/2km) Transceiver
MINI GBIC 2.5G 1310nm DFB (LC/15km) Transceiver
All SFP ended with D are with Diagnostic function
Lantech Communications Global Inc.
www.lantechcom.tw
info@lantechcom.tw
© 2016 Copyright Lantech Communications Global Inc. all rights reserved.
The revise authority rights of product specifications belong to Lantech Communications Global Inc.
Lantech may make changes to specification and product descriptions at anytime, without notice.
Datasheet Version 1.6
www.lantechcom.tw | info@lantechcom.tw
Download PDF
Similar pages