Product Overview
Type
DIN rail mount type Switching Mode Power Supply (SMPS)
Model
SP-0305
SP-0312
SP-0324
Appearances
&
Dimensions
Output
Input
Output power
Voltage
Frequency
Current consumption
Efficiency
Voltage
Current
Voltage adjustment range
Ripple
Voltage fluctuation ratio
Over-current protection
Reference
Type
[W37.5×H75×L65mm]
3W
100-240VAC~ (permissible voltage: 85-264VAC~)
50/60Hz
Max. 0.15A
67 to 74%
5VDC
12VDC
0.6A
0.25A
Max. ±5%
Max. 5%
Max. 0.5% (at 85-264VAC 100% load)
Min. 110%
P-4 to 7
General-purpose Switcing Mode Power Supply (SMPS)
SPASPASPASPASPASPA030-05 050-05 030-12 050-12 030-24 050-24
Model
24VDC
0.13A
SPA075-05
SPA100-05
SPA075-12
SPA100-12
SPA075-24
SPA100-24
(except for output voltage 5VDC )
Appearances
&
Dimensions
[W97×H40×L120mm]
Output power
Protect function
Output
Input
Voltage
※5
30W
50W
30W
[W97×H42×L160mm]
50W
30W
100-240VAC~ (permissible voltage: 85-264VAC~)
Frequency
※
Efficiency 1
Current
※
consumption 1
Voltage
Current
※
Voltage adj. range 4
※2
Input fluctuation
※
Load fluctuation 1
※1
Ripple
※
Starting time 1
※
Holding time 1
50/60Hz
Min. 60% Min. 67%
Max.
Max.
1.2A
1.6A
5VDC
6A
10A
±5%
Max. ±0.5%
Max. ±2%
Max. ±1%
Max. 200ms
Min. 10ms
Inrush current
protection
Max. 30A (100VAC)
Max. 20A (100VAC)
/Max.40A (240VAC)
Over-current
protection
Over-voltage
※
protection 3
Short protection
Reference
50W
Min. 110%
Min. 74%
Max.
Max.
1.0A
1.4A
12VDC
2.5A
4.2A
Min. 80%
Max.
Max.
0.8A
1.1A
24VDC
1.5A
2.1A
75W
100W
75W
100W
75W
100W
100-120/200-240VAC~
(permissible voltage: 85-132/170-264VAC~) switching type
Min. 70%
Max.
3.0A
5VDC
15A
20A
Min. 78%
Max.
2.0A
12VDC
6.3A
Min. 72% Min. 78%
Max.
Max.
3.0A
2.0A
24VDC
8.5A
3.2A
Max. ±1%
Max. ±2%
Max. ±1%
Max. 150ms
Max. 250ms
Min. 5ms
Min. 80%
Max.
2.5A
4.2A
Min. 10ms Min. 5ms Min. 10ms
Max. 35A Max. 45A
Max. 45A (100VAC)/ (100VAC) (100VAC) Max. 35A (100VAC)/
Max. 50A (240VAC) /Max. 40A /Max. 50A Max. 40A (240VAC)
(240VAC) (240VAC)
Min.
Min. 110%
105%
-
6.5V ±10%
16V ±10%
30V ±10%
Max. 5ms
P-8 to 11
Max. 10ms
Max. 5ms Max. 10ms Max. 5ms
※1: 100% load for rated input voltage (100VAC).
※2: Rated input voltage •SPA-030/050 Series: 100-240VAC (85-264VAC)
under 100% of load.
•SPA-075/100 Series: 100-120/200-240 (85-132/170-264VAC)
SPA-100-05 is under 100% of load for [100-120/200-240VAC (100-132/190-264VAC)].
※3: Rated input voltage (100VAC).
※4: The output voltage adjuster (V.ADJ) should be used within voltage adjustment range.
※5: The rated input voltage of SPA-100-05 is 100-120/200-240VAC (100-132/190-264VAC).
P-2
Product Overview
Type
Model
General-purpose Switcing Mode Power Supply (SMPS)
SPA-400-24
(A)
Photoelectric
Sensors
Line-up
(B)
Fiber
Optic
Sensors
Appearances
&
Dimensions
(C)
Door/Area
Sensors
(D)
Proximity
Sensors
[W120×H61×L204.8mm]
Protection
Output characteristics
Input condition
Output power
Voltage
Frequency
※1
220VAC~
Efficiency (typical)
Current consumption
220VAC~
(typical)
Leakage current (typical) 220VAC~
Voltage
Current
※2
Voltage adjustment range
Input variation
Load variation
Temperature drift
Ripple&Ripple noise
※1
220VAC~
Start-up time (typical)
※1
200VAC~
Hold time (typical)
Inrush current protection
220VAC~
※1
(typical)
Over-current protection
Over-voltage protection
Temp. rising limit
Remote control
Reference
400.8W
200-240VAC~ (permissible voltage: 190-264VAC~)
50/60Hz
85% (after 10min of power ON)
(E)
Pressure
Sensors
(F)
Rotary
Encoders
Max. 4.6A
Max. 1mA
24VDC
16.7A
22.8-25.2VDC
Max. ±0.5%
Max. ±1%
360mV
Max. 290mV
1800-2300ms
Max. 17ms
(G)
Connectors/
Connector Cables/
Sensor Distribution
Boxes/Sockets
(H)
Temperature
Controllers
(I)
SSRs / Power
Controllers
(J)
Counters
40A
110 to 160% (recovers automatically after the cause for over-current is removed)
27-33VDC
Yes
Yes (output voltage ON for shorting, output voltage OFF for open)
P-8 to 11
(K)
Timers
(L)
Panel
Meters
※1: It is for 100% load.
※2: The output voltage adjuster (V.ADJ) should be used within voltage adjustment range.
(M)
Tacho /
Speed / Pulse
Meters
(N)
Display
Units
(O)
Sensor
Controllers
(P)
Switching
Mode Power
Supplies
(Q)
Stepper Motors
& Drivers
& Controllers
(R)
Graphic/
Logic
Panels
(S)
Field
Network
Devices
(T)
Software
P-3
Product Overview
Type
DIN rail mount type Switching Mode Power Supply (SMPS)
SPB SPB SPB SPB SPB SPB SPB SPB SPB
-015 -015 -015 -030 -030 -030 -060 -060 -060
-05
-12
-24
-05
-12
-24
-12
-24
-48
Model
SPB
-120
-12
SPB
-120
-24
Line-up
SPB
-120
-48
SPB
-240
-12
SPB
-240
-24
SPB
-240
-48
Line-up
Appearances
&
Dimensions
[W22.5×H90×L90mm]
Input
Output power
Voltage
Frequency
Efficiency
(typical)
※1
※1
Power factor
[W30×H90×L90mm]
[W36×H100×L110mm]
15W 15.6W
25W 30W 31.2W 60W
62.4W
100-240VAC~ (permissible voltage: 85-264VAC~/120-370VDC )
50/60Hz
100VAC~ 77% 80% 83% 77% 82% 84% 81% 84% 85%
240VAC~ 76% 79% 82% 78% 83% 85% 83% 86% 87%
-
[W50×H115×L110mm]
96W
120W
82% 82%
85% 85%
Min. 0.9
[W80×H115×L110mm]
240W
85%
88%
87% 89%
90% 92%
Min. 0.9
89%
92%
Current
100VAC~ 0.35A 0.35A 0.34A 0.56A 0.63A 0.63A 1.24A 1.21A 1.19A 1.19A 1.49A 1.43A 2.76A 2.71A 2.73A
※1
consumption
240VAC~ 0.19A 0.19A 0.19A 0.30A 0.35A 0.35A 0.66A 0.65A 0.64A 0.52A 0.61A 0.61A 1.14A 1.12A 1.13A
(typical)
Output
Power factor correction circuit
Voltage
Current
※2
Voltage adjustment range
※3
Input variation
Load variation
Ripple&Ripple noise
※1
Start-up time
(typical)
Protection
Hold time
(typical)
※1
※1,※4
100VAC~
240VAC~
100VAC~
240VAC~
5VDC 12VDC 24VDC
3A
1.3A 0.65A
Max. ±10%
Max. ±0.5%
Max. ±1%
Max.
Max. ±1%
±1.5%
500ms 550ms 650ms
550ms 550ms 650ms
24ms 25ms 25ms
190ms 190ms 190ms
Inrush current 100VAC~ 7A
7A
7A
protection
240VAC~
32A
30A
31A
(typical)
※4
Over-current protection 105 to 160%
Over-voltage protection
5VDC 12VDC 24VDC
5A
2.5A 1.3A
Max. ±10%
Max. ±0.5%
Max. ±1%
Max.
Max. ±1%
±1.5%
600ms 550ms 550ms
600ms 550ms 550ms
20ms 15ms 15ms
130ms 110ms 110ms
12VDC 24VDC
5A
2.5A
Max. ±5%
Max. ±0.5%
Max. ±1%
48VDC
1.3A
Max. ±1%
520ms
530ms
15ms
100ms
550ms
550ms
14ms
110ms
48VDC
2.5A
Max. ±1%
1200ms
400ms
15ms
108ms
1200ms
400ms
98ms
97ms
760ms
280ms
81ms
81ms
1200ms
400ms
87ms
86ms
Built-in
12VDC 24VDC 48VDC
20A 10A 5A
Max. ±5%
Max. ±0.5%
Max. ±1%
Max.
Max. ±1%
±1.5%
75ms 87ms 75ms
45ms 56ms 45ms
33ms 36ms 25ms
33ms 36ms 25ms
7A
7A
6A
13A
14A
10A
9A
16A
10A
8A
8A
8A
29A
31A
29A
19A
17A
37A
37A
20A
37A
22A
25A
26A
58.0V
±10%
43.0V
±10%
105 to 160%
16.0V 30.0V
±10% ±10%
10.0V 20.0V
±10% ±10%
105 to 160%
105 to 160%
105 to 160%
16.0V 30.0V
±10% ±10%
4.2V 9.6V 20.0V 4.2V 9.6V 20.0V 9.6V 20.0V 43.0V 9.6V 20.0V
±10% ±10% ±10% ±10% ±10% ±10% ±10% ±10% ±10% ±10% ±10%
P-12 to 15
Output low-voltage
indicate
Reference
※1: It is for 100% load.
※2: The output voltage adjuster (V.ADJ) should be used within voltage adjustment range.
※3: It is for the rated input voltage 100-240VAC (85-264VAC), and 100% load.
※4: It is for the rated input voltage 100-240VAC.
P-4
Built-in
12VDC 24VDC
8A
5A
Max. ±5%
Max. ±0.5%
Max. ±1%
58.0V
±10%
43.0V
±10%
Download PDF