Telephone actuator
F461/2
Description
The telephone actuator enables remote control of two users (e.g. boilers, garden
watering, staircase light, garden light, rolling shutters, etc.) using the fixed, or the
mobile telephone line.
Remote control and programsng are protected by a password consisting in a 4 digit
code that can be customised by the customer; the default code is 1234. During the
programsng procedure, it is possible to select three operating modes:
-LIGHTING
It can be used to enable/disable users such as staircase lights, garden lights, boilers, etc.
-AUTOMATISMS
It can be used to activate the rolling shutter motors (up/down movement), as well as
other motors.
-TEMPERATURE CONTROL
To enable or disable the boilers; used together with the BTicino timer thermostat.
The activation, deactivation, check and programsng controls must be sent from the
actuator using only a DTMF telephone; if other types of telephones are used, the
actuator does not work. In order to control more than two users, it is possible to install
on the same telephone line up to four actuators, in parallel on the line.
The operation of the actuators is guaranteed even if an answering machine is installed
on the telephone line.
Technical data
Network Power supply:
Dissipated power:
Absorption:
Operating temperature:
Telephone network: Weight:
Connection to the
telephone network: Connection to the PABX Dialling system: Relay number: Relay output contacts: Front view
11
10
9
1
2
3
4
8
5
7
6
Legend
230 Vac ± 10 % 50Hz
11 VA
50 mA
0 – 35 °C
analogue (PSTN)
270 grams
1. Screw clamps (C2): uscita contatti in scambio del relè 2
2. Yellow LED: relay (C2) status. ON = relay active
3. RJ8 female connector: to connect the actuator to the telephone using the cable
supplied, and activate the programming procedure
4. Pushbutton (C2) for local activation of relay 2
5. PROG/LINE selector:
two-wire with telephone pair
two-wire with telephone pair
only with touch tone dialling (DTMF)
2 with independent control and changeover contacts
230 Vac 6A resistive, 2A inductive both between N-NC and N-NO
Dimensional data
3 DIN modules.
MQ00380-b-EN
- in PROG position: operation in programming mode
- in LINE position: normal operation
6. Screw clamps (LU): telephone line input
7. Screw clamps (PRI): power supply 230 Vac
8. Green LED : operating mode:
OFF = actuator faulty or incorrectly powered
On steady = powered and normal operation
ON flashing = powered and in programming mode operation
9. Pushbutton (C1) for local activation of relay 1
10.Yellow LED: relay (C1) status. ON = relay active
11.Screw clamps (C1): output of changeover contacts of relay 1
22/04/2014
1
Telephone actuator
F461/2
Configuration
The programming procedure is performed using a standard touch tone telephone, connected
to the RJ8 socket of the actuator, using the appropriate cable, supplied as standard.
1.............. 4.............. 7..............
2.............. 5.............. 8..............
3.............. 6.............. 9..............
To program the telephone actuator move
the selector (3) to “PROG”, and enter the
commands on the telephone connected to
the connector (4). The programming cable
is supplied as standard.
The actuator can be programmed to operate in three different modes:
-lighting: to enable or disable lights, boilers, etc.;
-automation: to activate the rolling shutter motors (closing – opening), or other motors;
-temperature control: to activate or deactivate the heating or the air conditioning
system to be used with the BTicino timer thermostat item HC/HS/HD/L/N/NT4451 and
item AM5721.
Also, in the three operating modes the two relays can themselves be programmed to
operate with the monostable function (once timed, the relay closes for the programmed
time; ideal, for example, when timed switching on of the staircase lights is required), or
bistable (ON - OFF, at every command the relay changes its status and keeps it until a new
command is received, behaving as a switch).
The actuator can also be connected to an internal telephone extension (shunted), when
a PABX BTicino telephone switchboard is present (to expand the number of relays that
can be selected remotely); it is also possible to connect in parallel to each other on the
same telephone line up to 4 actuators, even if an answering machine is also installed.
At the end of each programming operation the actuator sends to the telephone receiver a
confirmation (programming correct) or an error (programming failed) tone.
MQ00380-b-EN
2
LIGHTING MODE
In this mode the two relays can be enabled independently, and can also be programmed
with different functions.
A user can be activated with “impulsive” monostable operation using relay 1 (Example
1: timed switching on of the staircase light), and with “ON/OFF” bistable operation using
relay 2 (Example: boiler activation/deactivation).
TEMPERATURE CONTROL MODE
This mode enables to combine the telephone actuator to the operation of the BTicino
timer thermostat, item HC/HS/HD/L/N/NT4451 and item AM5721.
Using this mode, it is possible to remotely change the operation of the timer thermostat.
If the timer thermostat is in any AUTO, MAN, ANTIFREEZE, PARTY, HOLIDAY, or OFF
condition, by activating the following controls on the actuator:
-ANTIFREEZE, the timer thermostat will switch to the antifreeze condition, until an
unlocking command is received;
- AUTO, the timer thermostat will switch to the automatic condition.
AUTOMATISM MODE
In this mode, the two relays are both controlled using the same command and cannot be
activated independently from each other.
Therefore, when relay 1 is programmed, the actuator will automatically also manage
relay 2.
The AUTOMATISM mode is recommended for controlling users interlocked with each other,
such as the operation of a rolling shutter (up/down), motors (forward/backwards), etc.
For more details see the instruction leaflet supplied with the device.
22/04/2014
Telephone actuator
F461/2
Wiring diagrams
max. 230 V
6 A resistive
2 A inductive
U
User 2
max. 230 V
6 A resistive
2 A inductive
Telephone line
U
User 1
a b
IN
Telephone
actuator
PLT1
Telephone
protection
It is possible to connect up to 4 devices on the same
telephone call. The devices must be numbered
progressively. It is very important that each device
has its own unique identification number.
OUT
a b
230 Vac
50 Hz
V˜
V˜
Telephone line
U1
NOTE:
The devices must be numbered
progressively during the programming
procedure. It is very important that each
device has its own unique identification
number.
V˜
U2
U7
C1
Actuator No. 1
(main)
a b
IN
Telephone
protection
PLT1
OUT
a b
230V
0,5A
2A
C2
5A cos=0,5
6A
Timer thermostat
NA C NC
Actuator No. 4
(secondary)
230V 50 Hz
50 mA
PRI
230 Vac
50 Hz
U8
2
Remote
a
LU
ext NTC
b
To the loads
to be controlled
2
Remote
activation
Contact open
automatic program
(last one selected)
Contact closed
manual antifreeze
program
MQ00380-b-EN
22/04/2014