User Manual MA 21 Two zone mixing amplifier Safety instructions When using this electronic device, basic precautions should always be taken, including the following: 7 The power supply should be undamaged and never share an outlet or extension cord with other devices. Never leave device plugged into the outlet when it is not being used for a long period of time. 8 Care should be taken that objects do not fall into liquids and liquids would not be spilled on the device. 1 Read all instructions before using the product. 2 Do not use this product near water (e.g., near a bathtub, washbowl, kitchen sink, in a wet basement or near a swimming pool etc). 3 Use this device when you are sure that amplifier has a stable base and it is fixed securely. 4 This product, in combination with loudspeakers may be capable of producing sound levels that could cause permanent hearing loss. Do not operate for a long period of time at a high volume level or at a level that is uncomfortable. If you experience any hearing loss or ringing in the ears, you should consult with otorhinolaryngologists. 9 The product should be serviced by qualified service personnel if: – The power supply or the plug has been damaged. – Objects have fallen into or liquid has been spilled on the product. – The product has been exposed to rain. – The product has been dropped or the enclosure damaged. 10 There are some areas with high voltage inside, to reduce the risk of electric shock do not remove cover of the amplifier. The cover should be removed by the qualified personnel only. 5 The product should be located away from heat sources such as radiators, heat vents, or other devices that produce heat. 6 The product should be connected to a power supply that is described in the operating instructions or are marked on the product. USER MANUAL MA 21 Two zone mixing amplifier CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN To reduce the risk of electric shock, do not remove screws. No user-serviceable parts inside. Refer servicing to qualified service personnel. To reduce the risk of fire, electric shock or product damage, do not expose this apparatus to rain, moisture, dripping or splashing and that no objects filled with liquids, such as vases, shall be placed on the apparatus. y Table of contents Before you start Introduction.......................................................................................................................................................3 Features.................................................................................................................................................................3 Operation Front panel.........................................................................................................................................................4 Rear panel...........................................................................................................................................................4 o Function description of MA 21 amplifier. 5 ......................................................................................5 2 Function description of paging microphone Talk St Z2....................................................7 Specifications General specifications.................................................................................................................................8 x USER MANUAL MA 21 Two zone mixing amplifier y Before you start MA 21 two zone mixing amplifiers for commercial and industrial applications. Possibility to plug in two zone paging microphone or set microphone input to selected zone by using logic inputs in 5 pin XLR conector. Low impedance speaker lines designed in paralel to 100 V outputs. Line input selector for each zone allows to broadcast different background music into zones. Amplifier is ideal for two zone application, but can be used in stereo background music system as well. FEATURES 03 • Two 100 V or low impedance zones • AB class audio amplifier • Line input selector for both zones • XLR microphone and control inputs • Priority input MIC 1 USER MANUAL MA 21 Two zone mixing amplifier • Connector for two zone paging microphone • Separate tone and master control for both zones • XLR and RCA inputs connectors • RCA preamp output • Phantom power Operation Front Panel 1 2 3 4 5 6 7 8 9 1. Mic input level control | 2. Line input selector | 3. Line input level control | 4. Tone control - bass | 5. Tone control - treble 6. Zone 2 master level control | 7. Zone 1 master level control | 8. Output level indicator | 9. Power switch 1 2 3 4 5 6 7 8 Rear Panel 1. Main powe connector and fuse 2. Main voltage selector | 3. 100V amplifier output | 4. low impedance output | 5. preamp output | 6. line level audio input 7. paging micropohe input | 8. microphone input 04 USER MANUAL MA 21 Two zone mixing amplifier Operation Function description of MA 21 amplifier MIC INPUT LEVEL CONTROL These rotary knobs are designed for adjusting volume level of the 3 pin and 5 pin XLR inputs. First three inputs can be used for microphone level audio only. LINE INPUT SELECTOR This knob allows to select and broadcast to zone one of three audio source connected to line level RCA inputs. Individually for both zones input selector gives a opportunity to broadcast different background music to different zones. LINE INPUT LEVEL CONTROL These two knobs designed for adjusting volume level of line audio input. TONE CONTROL The separate tone controls provide attenuation of bass and treble response. The flat position is obtained when the knobs are set to middle position. Turn bass control knob (BASS) and treble tone control knob (TREBLE) clockwise to raise tone level by approximately +10 dB; turn counterclockwise to lower tone level by approximately -10 dB. 05 USER MANUAL MA 21 Two zone mixing amplifier MASTER LEVEL CONTROL This potentiometer is designed to adjust audio level in the main output. OUTPUT LEVEL INDICATOR These two led bars indicates output signal amplitude of both zones. If the red led indicator starts lighting continuously please decrease the sound volume by using master control, because red led bar indicates too high signal level. First led in led bar is main power indicator. POWER SWITCH Use this switch to power on or off the amplifier. Green led in the front panel led bar lights up if the amplifier is powered. MAIN POWER CONNECTOR AND FUSE Power connector is designed for main powers connecting to amplifier. This connector is combined with fuse holder and 4A 250V fuse. MAIN VOLTAGE SELECTOR Allows to select main power voltage. Set the proper voltage before the first time turning on amplifier according to your area: ~115 V (60 Hz) or 230 V (50 Hz). Operation Function description of MA 21 amplifier 100V OUTPUT Output terminal is designed to connect speaker line to amplifier. There are available two types of output: low impedance 8 Ω and 100 V outputs for constant voltage audio line. Each of the amplifier zones can run only one output configuration at the same time. Operating amplifier using 8 Ω and 100 volt concurrently may cause damage to the amplifier or connected speakers. LOW IMPEDANCE OUTPUT Output designed for 8 Ω loudspeakers. Operating amplifier using 8 Ω and 100 volt concurrently may cause damage to the amplifier or connected speakers. 06 Paging microphone input pinout 5pin XLR connector: 1. GND | 2. MIC audio signal + | 3. MIC audio signal - | 4. Zone 2 mute trigger | 5. Zone 1 mute trigger MIC 2 and MIC 3 input zoning can be controlled by external buttons, relays or external devices as well. Application and circuit diagram: Microphone is muted in both zones PREAMP OUTPUTS This is line level RCA output to connect audio recording equipment or any other purpose. Subwoofer out and record out are the same type preamp output connected in parallel inside the amplifier. Microphone is muted in zone 2 LINE LEVEL AUDIO INPUT RCA input for line level audio. Signal from line inputs can be selected and broadcast to zones by using line input selector located in the front panel. Microphone is muted in zone 1 PAGING MICROPHONE INPUT This input is designed to connect Talk St Z2 paging microphone to amplifier. 5 pin XLR connector’s audio inputs pin’s and 3 pin XLR are connected in parallel with each other, because of this reason please connect only one microphone in one MIC input. MICROPHONE INPUT This is balanced microphone input. This input as well as MIC 2 and MIC 3 inputs are suitable for dinamic microphones only. MIC 1 input is priority input. USER MANUAL MA 21 Two zone mixing amplifier Operation PHANTOM POWER Phantom power can be activated inside the amplifier for all XRL inputs individually. In order to activate phantom power remove amplifier’s top cover and set phantom power jumpers to position ON. Jumpers are located in the input board near the XLR connectors. All XLR input has its own jumper. Turn on phantom power for input which will be used with condenser microphone. For dynamic type microphones phantom power must be disabled. 07 USER MANUAL MA 21 Two zone mixing amplifier ON OFF ON OFF Operation Function description of paging microphone Talk St Z2 INPUT CONNECTOR Designed to connect gooseneck microphone. 3 pin XLR connector. 5 1 ZONE 1 SWITCH Disables microphone mute in zone 1 and allows make announcement in this zone. ZONE 2 SWITCH Disables microphone mute in zone 2 and allows make announcement in this zone. ALL ZONES SWITCH Disables microphone mute in zone 1 and zone 2 and allows make announcement in these zones. OUTPUT CONNECTOR Designed to Talk St Z2 to MA 21 amplifier. 5 pin XLR connector. Max distance between amplifier and Talk St Z2 is 20 m. Distance can be increased if separate shielded microphone cable is used to transmit audio signal from Talk St Z2 to audio amplifier. 2 3 4 1. Input connector |2. Zone 1 switch | 3. Zone 2 switch | 4. All zones switch | 5. Output connector Talk St Z2 cable diagram 1 2 5 3 4 1 5 4 3 2 1. GND | 2. Audio signal + | 3. Audio signal - | 4. Zone 2 mute signal | 5. Zone 1 mute signal 08 USER MANUAL MA 21 Two zone mixing amplifier General Specifications Amplifier Power supply AC 230 V/115 V 50/60 Hz SN range < 70 dB AC power consumption 500 W @ full power Dimensions H x W x D 88 mm x 425 mm x 305 mm Output Power 2 X 100 W Weight 9 kg Total Harmonic Distortion 0.05 % @ 1KHz Phantom power voltage +13 V Input sensitivity XLR - 57 dBu RCA -10 dBu Frequency Response 8 Ω output 20 Hz - 20 kHz 100 V output 50 Hz - 18 kHz Priority input MIC 1 Output 8 Ω output binding post connector 100 V output screw terminal Preamp out level + 2 dBu The specifications are correct at the time of printing this manual. For improvement purposes, all specifications for this unit, including design and appearance, are subject to change without prior notice. 10 USER MANUAL MA 21 Two zone mixing amplifier