Stand Alone Reader
1
Manual
DG-160
Features
1. Slim type keypad design.
Stand Alone Reader
2
Manual
Specifications
Operating Voltage 12VDC
Indicator Status & Default Setting Parameters
programming time up to 0.5 second.
b. PIN or Proximity Card
Current Draw Pull In:60mA@12VDC, Holding:30mA@12VDC
c. PIN + Proximity Card
4. Logical memory prevents duplicated card setting.
times invalid PINs or unsuccessful card attempts. (The keypad without beep
during the period time).
6. Controller with keypad sound to avoid incorrect key-in.
8. Built-in tamper switch.
44
LED
Input
1 contact for door reed switch
Standby
Output 2 relays (Dry contacts: N.O./N.C./Com.)
LED Status Indication 2 LED indicators display (Red/Green)
+
12VDC
Signal
Status
Green On
First relay active
Red On
Second relay active
Yellow Stay On
Enter programming mode
Green Stay On
The slot position of first relay is available.
Programming Red Stay On
2 contacts for Request-To-Exit button
7. Additional input for anti-tailgating function to ensure high security access
control.
Standby
Keypad Backlit 12-digit (0~9,*,#)
5. Lockout Function: The controller will lockout for 60 seconds after entering 5
Operation Instruction
+
N.C1
Beep
The slot position of second relay is available.
Red Stay On
The slot position of second relay is unavailable.
1 Beep
Valid card, key press, enter programming mode
3 Beeps
Invalid card, incorrect PIN
Programming
3 Beeps
Memory Volume 1000+10 proximity cards/tokens and PINs
N.O1
of total power failure.
Varistor
(MUST install a Varistor)
PB2
Exit Button 2
REED
REED
Correct Input data, Exit programming mode
Incorrect Input data, other incorrect operation,
GND
11. Aluminum alloy casing designed with vandal resistant screws for enhanced
Aluminum alloy casing design
safety and durability.
Non-volatile memory
Epoxy sealed for waterproof
12. Epoxy sealed for waterproof grade IP65.
Operating Temperature -20°C~70°C
151.5
Built-in tamper switch
Lockout function
Warranty:
The product is warranted against defects in material and workmanship while used
Slim type keypad design
in normal service for a period of 1 year from the date of sale to the original
Logical memory
customer. The GEM policy is one of continual development and improvement;
Dual relays output
For DC use only
For AC/DC
Electric Lock 2
Fail-Secure Mode
therefore GEM reserves the right to change specifications without notice.
Access Mode
Proximity Card Only
Format
All Bits
Card Storage (MAX. 1000+10 pcs)
None
Master Code
12345 (5 digits)
Alarm Function (All)
Function disabled
Relay Strike Time (Time Delay Setting)
5 seconds
Pressed Key Time Delay
5 seconds (Fixed)
PIN Code Input Waiting Time
5 seconds
Programming Mode Time Delay
25 seconds (Fixed)
Enter the master code twice (12345 12345) to enter programming mode (1
long beep, Right Yellow LED stay on).
3. Setting the Access Mode
The dual authentication feature allows the keypad to be programmed to grant
Stand Alone Reader
6
Manual
+
12VDC
Power Supply Unit
1. Enter programming mode
2. Press *0 (Right Yellow LED rapid flash)
+
Black
Pink
White
Green
Grey
Purple
N.C.1
Blue
N.C.2
COM.2
N.O.2
COM.1 Orange
P.B.1
N.O.1 Yellow
GND Brown
P.B.2
REED
Note:
1. It is suggested to use a linear power supply unit to prevent reading range
reduction at the card reader.
2. It is suggested to use #22~26 AWG insulation wire.
3. Exit button is at N.O. contact.
4. With CE qualification EMC specification.
5. The door strike or relay must have a varistor or a diode across the door strike
3. Press 00 (1 beep, Right Yellow LED stay on) for Proximity Card Only
1. Enter programming mode
2. Press *4 to select slot position 00~09 (Left Red LED stay on, Right
2. Enter *8 (Right Yellow LED rapid flash)
stay on, Right Yellow LED rapid flash to indicate the slot position is available)
Yellow LED stay on).
3. Press 00~99 (1 beep, Right Yellow LED stay on)
the relay contacts and electronic components, or even burns the controller.
4. Press # (1 beep) back to standby mode (Right Green LED stay on)
stay on)
4. Press # (1 beep) back to standby mode (Right Green LED stay on)
10. Add a New Master Card to Relay 1
a.
2. Press *7 (Left Green LED rapid flash, Right Yellow LED rapid flash to
indicate the slot position is available)
b.
3. Read new card to set as Master Card (1 beep, Right Yellow LED stay on)
1. Enter programming mode to select slot position 000~999 (Left Red LED stay
4. Press # (1 beep) back to standby mode (Right Green LED stay on)
on, Right Yellow LED rapid flash to indicate the slot position is unavailable)
2. Press ** (1 beep) to delete the data from the slot position (Left Green
b.
2. Press *7 (Left Green LED stay on, Right Yellow LED rapid flash to
3. Repeat the steps of 7-a to add new card.
indicate the Master Card had been stored)
8. Adding a Proximity Card and PIN to Relay 2
3. Press ** to delete the data from the slot position (1 beep, Left Green
a.
LED rapid flash, Right Yellow LED rapid flash)
1. Enter programming mode
2. Press *4 to select slot position 00~09 (Left Green LED stay on, Right
Yellow LED rapid flash to indicate the slot position is available)
3. Read new card (1 beep, Right Yellow LED stay on)
1. Read master card once (1 beep, Right Yellow LED stay on)
2. Enter slot position 001~999 (Left Red LED stay on, Right Yellow LED
rapid flash to indicate the slot position is unavailable)
3. Press ** to delete the data from the slot position (1 beep, Left Green
LED stay on, Right Yellow LED rapid flash)
4. Repeat the steps of 11-1 to add new card.
12. Turning Anti-Tamper Alarm Function ON/OFF
1. Enter programming mode
3. Press 01 (1 beep, Right Yellow LED stay on) – function OFF
Press 02 (1 beep, Right Yellow LED stay on) – function ON
4. Press # (1 beep) back to standby mode (Right Green LED stay on)
13. Turning Doorbell Alarm Function ON/OFF
1. Enter programming mode
2. Press *2 (Right Yellow LED rapid flash)
1. Enter programming mode
LED stay on, Right Yellow LED rapid flash)
4. Press # (1 beep) back to standby mode (Right Green LED stay on)
b.
2. Press *6 (Right Yellow LED rapid flash)
1. Enter programming mode
NOTE: Master codes must NOT be the same as PIN codes.
NOTE: For both Relay 1 & Relay 2, enter 00 will set the relay strike time
terminals to suppress the back EMF of the strike – failure to do so will damage
2. Press *3 (Right Yellow LED rapid flash)
3. Press # (1 beep) back to standby mode (Right Green LED stay on)
unlocked after a valid proximity card or PIN is entered.
Press *5 for Relay 2 (Right Yellow LED rapid flash)
1. Enter programming mode
3. Enter 5-digit master code twice e.g. 45678 45678 (1 beep, Right Yellow LED
2. Read new card (1 beep), then press 5-digit PIN 99999(1 beep, Right
The relay strike time determines the amount of time that the door remains
2. Press *1 for Relay 1 (Right Yellow LED rapid flash
4. Repeat the steps of 8-a to add new card.
9. Change Master Code
1. Enter programming mode to select slot position 000~999 (Left Green LED
4. Setting the Relay Strike Time
to 0 second (relay set to toggle mode).
LED stay on, Right Yellow LED rapid flash)
1. Enter programming mode
a.
Yellow LED stay on)
3. Press ** to delete the data from the slot position (1 beep, Left Green
6. Reset Controller Parameter to Default Value
7. Adding a Proximity Card and PIN to Relay 1
rapid flash to indicate the slot position is available
3. Read new card (1 beep), then enter 5-digit PIN 99999 (1 beep, Right
Yellow LED rapid flash to indicate the slot position is unavailable)
4. Press # (1 beep) back to standby mode (Right Green LED stay on)
4. Press # (1 beep) back to standby mode (Right Green LED stay on)
1. Read master card once (1 beep, Right Yellow LED stay on)
Stand Alone Reader
9
Manual
Annex: User List
2. Enter slot position 001~999 (Left Green LED stay on, Right Yellow LED
1. Enter programming mode
4. Press # (1 beep) back to standby mode (Right Green LED stay on)
1. Enter programming mode
4. Press # (1 Beep) back to standby mode (Right Green LED stay on)
2. Press *8 (Right Yellow LED rapid flash)
3. Enter 99 (Both left & right Yellow LED stay on, 1 beep) back to standby mode
Stand Alone Reader
8
Manual
b.
3. Press 88 (Right Yellow LED stay on, 1 long beep)
Press 01 (1 beep, Right Yellow LED stay on) for Proximity Card or PIN
Press 02 (1 beep, Right Yellow LED stay on) for Proximity Card + PIN
Stand Alone Reader
7
Manual
5. Clear Memory of All Proximity Cards and PINs
access with either Proximity Card only, or PIN, Proximity Card and PIN.
Light
Green
Factory Default Setting:
Ambient Humidity 5%~95% (Non-condensing)
Door Closed=N.O.
Door Opened=N.C.
duplicated card setting
Relay Electric Current Max. 2A@30VDC, 0.6A@120VAC
Relay Strike Time 01~99 seconds or Toggle Mode(00)
2. Enter Programming Mode
COM2
N.O2
Under normal operation the keypad is used for entering PIN to gain access.
relay strike time and other operation functions.
+
N.C2
cannot be the same as other PINs. The default master code is set to 12345.
In the pro-gramming mode the keypad can be used to add/delete PINs, set
Exit Button1
Red
10. Dual relays to control door lock and other security devices.
Anti-tailgating function
1. Master Code
ramming functions of the digital keypad and cannot be used for access i.e. It
Electric Lock 1
Fail-Safe Mode
PB1
The slot position of first relay is unavailable.
Green Stay On
1 Beep
COM1
9. Non-volatile memory stores all code settings for a long time, even in the event
Up to 1000+10 PINs
Power Supply Unit
+
Right Green Stay On Power on, Standby
RF Frequency EM 125KHz
Read Range 5 cm (In noise-free environment)
Wiring Diagram
Stand Alone Reader
5
Manual
The master code comprises of a five-digit number and is used to access progMode
3. Access modes:
a. Only Proximity Card (default setting)
Stand Alone Reader
4
Manual
Beep & LED Indication:
2. Memory volume up to 1000+10 proximity cards/tokens and PINs with the
St a n d Al o n e R ea d e r
O p e r ati on Man u a l
24
Stand Alone Reader
3
Manual
4. Repeat the steps of 10-a to add new master card.
3. Press 01 (1 beep, Right Yellow LED stay on) – function OFF
Press 02 (1 beep, Right Yellow LED stay on) – function ON
4. Press # (1 beep) back to standby mode (Right Green LED stay on)
14. Reset the Master Code to Default Value
Turn off the power: Press # continuously, and energized (1 beep) the master
code is reset to default value.
User User Name
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
11. Add New Cards by Master Card
a.
Copyright © All Rights Reserved.
P-MU-DG-160 Ver. A Publish: 2009.12.16
Slot Number
Card#/PIN#
Download PDF