SAFERUN® Pump Condition Monitoring System
Richter SAFERUN
®
• Integrated explosion protection
• Condition monitoring
with
w
o
N
!
W
NE
Speed-independent
power monitoring
Temperature monitoring
to ATEX
SIL1 certified
SIL
SAFERUN
®
Integrated explosion
protection for magnetic
drive pumps MNK
The SAFERUN® pump monitoring system continuously monitors
and measures the operating data of the magnetic drive pump MNK.
The SAFERUN® pump monitoring system
aSAFERUN® transducer CMS-T
bSAFERUN® can system CMS-S
cThe sensor cable connects can
system and transducer
dPDA
e Intrinsically safe power supply
SAFERUN® consists of two components, the transducer
SAFERUN® CMS-T and the can system SAFERUN® CMS-S. The
­sensor ­in­te­grat­ed in the can measures the pump power, speed
and ­temperature of the pump at the operating point. The sensor
is i­nstalled protected in the double can and so a material selection
of the measuring probe tip can be dispensed with in the case of
aggressive fluids.
1
The current operating point is visualised at the installation site
by the SAFERUN® transducer with traffic-light LEDs. The
­measurements and operating data are also stored in a data
memory (“History log”) for later analysis. Other pump-specific
data, e.g. operating hour counter, can be displayed by
using a PDA. SAFERUN® is completely assembled
at Richter and parameterised for the respective pump.
3
2
Function
The pump power is compared with the performance curve
allowing for the current speed and the condition is displayed
by the traffic-light LEDs and output via a 4-20 mA signal.
All mea­surements can also be indicated via HART. The HART
signals can be converted into analog 4-20 mA by means of a
HART loop con­verter installed in the control cabinet.
When SAFERUN® is used as a temperature monitor in accordance
with ATEX, the temperature signal, instead of the power signal, can
be indicated as a 4-20 mA signal.
All operating data are also stored in the History log in the
SAFERUN® transducer and are also available without power.
Customer benefits
•Integrated explosion protection with SIL1-certified power and
temperature monitor – no additional sensors required for
constant fluid data
•Increase in plant availability due to detection and avoidance
of abnormal pump modes of operation, e.g. drive stoppage
•Transparency on site thanks to the traffic-light LED display of the
current operating point of the pump
•Time and money savings due to reduction in repairs by the
detection of abnormal operating conditions at variable speed,
e.g. lack of lubrication of the plain bearings
•Cost benefits by avoiding of wetted sensor technology as the
SAFERUN® sensor is integrated in the double can
5
Parameterisation
SAFERUN® is parameterised at Richter with
the fluid data from the pump data sheet and
is immediately ready for operation in the plant.
If the pump is used as a process pump with
fluctuating fluid properties, the pump can be
simply parameterised again using the PDA
after the initial run-in phase.
Transducer CMS-T
Service
message
RFID
(History log)
Operation
display
Load changes/
drive stoppage
Lack of
lubrication
2
4
Max. delivering rate
exceeded
Safe
operating range
PDA
Data is exchanged with the SAFERUN® using the PDA
and the RFID interface. The stored data permit an accurate analysis of the operating data at any time and support the operator with the optimisation of the application.
Equally, pump-specific data, e.g. operating hours and
energy consumption, can be read out. Naturally, the limit
values set as well as fluid data for optimum monitoring
can be adapted in the case of process pumps.
Main menue
Options
The magnetic drive pump MNK can be supplied
•directly with a SAFERUN® attached
•prepared for a SAFERUN® with the can CMS-S for
the subsequent attachment of the transducer CMS-T
• Sensor cable 5 m for fixation on site
• PDA with RFID reader and software
• HART loop converter
Menue “Parameter“
Login menue
Power
Speed-independent power monitoring due to
speed-dependent parameterisation (at Richter)
Operating points
Speed
3
SAFERUN
®
Technical Data
Dimensions
in mm
SAFERUN® CMS-T transducer
IP protection class (EN 60529) 67.5
118
IP 65
Housing material
ABS, modified (service resistance ≤ 106 Ω)
Spring-cage terminals
max. line cross-section 1.5 mm2
Cable connection
3-core, with shield
Sensor cable
0.3 m optionally 5 m
Ambient temperature
-20 °C to +60 °C (-5 °F to +140 °F)
Ignition protection class
category 2G (gas):
category 2D (dust):
II 2 G Ex ib IIC T4...T6
II 2 D Ex ibD 21 T 130 °C
Ambient temperature range
category 2G (gas): T6: -20 °C ≤ Ta ≤ +40 °C
T4: -20 °C ≤ Ta ≤ +60 °C
category 2D (dust): -20 °C ≤ Ta ≤ +60 °C
22
138
Power supply
With separator (3-line circuit) in the ignition protection class „Intrinsic safety ia or ib“
20
10
115
X
VDC/VAC
2
5
3
LN
L+
L
4
O4...20 mA
O+ HART
SAFERUN® CMS-S
3 4 5
3
Date and time at the time of measurement
Temp
Temperature in °C
RPM
Speed in rpm
Power
Pump power in kW
Percent
Percentage of the output signal
4-20 mA (0-100 %)
Analog
4 ... 20 mA
HART
Temperature, speed, power, mA, %
Max. measurement deviation
Power: ±6 %
Temperature: ±2 °C (±36 °F)
Speed: ±4 rpm
HART driver
Generic HART DTM
HART subordinate commands
Universal commands
HART supported boards Point-to-point
HART variables
4
5
6
rimary: Temperature (°C)
P
Secondary: Speed (rpm)
Tertiary: Power (kW)
O+
L-/O-
L+
2
DateTime
black
blue
brown
white
1
38 nF
Outputs
1
1 2
750 mW
Maximum internal capacity Ci
7
8
9
SAFERUN® CMS-T
Presented by:
Richter Chemie- Technik GmbH
Otto-Schott-Str. 2, D-47906 Kempen, Germany
Tel. +49(0) 21 52/146-0, Fax +49(0) 21 52/146-190
www.richter-ct.com, richter-info@idexcorp.com
4
Publication No. 713en 05.12 © Richter Chemie-Technik GmbH. Subject to change without notice. Printed in Germany. Richter and SAFEGLIDE®: TM Richter Chemie-Technik GmbH
39
51
R 3.5
73
50 mA-120 mA
Maximum input power Pi History log
70
95
28 VDC
Input amperage Ii
Maximum internal inductivity Linegligible
X
32
Input voltage Ui 