25HCE4 Comfort™ 14 Heat Pump with Puronr Refrigerant 1---1/2 to 5 Nominal Tons Product Data INDUSTRY LEADING FEATURES / BENEFITS Efficiency S 14 SEER / 11.0 -- 11.7 EER / 8.2 HSPF S Microtube Technologyt refrigeration system S Indoor air quality accessories available Sound S Sound level as low as 69 dBA S Sound levels as low as 68 dBA with accessory sound blanket Comfort S System supports CôRt, Edger or standard thermostat controls Reliability S S S S S S S S Non--ozone depleting Puronr refrigerant Scroll compressor Internal pressure relief valve Internal thermal overload High pressure switch Loss of charge switch Filter drier Balanced refrigeration system for maximum reliability Durability Carrier heat pumps with Puronr refrigerant provide a collection of features unmatched by any other family of equipment. The 25HCE4 has been designed utilizing Carrier’s non--ozone depleting Puronr refrigerant. NOTE: Ratings contained in this document are subject to change at any time. Always refer to the AHRI directory (www.ahridirectory.org) for the most up--to--date ratings information. WeatherArmort protection package: S Solid, durable sheet metal construction S Dense wire coil guard S Baked--on powder paint Applications S Long--line -- up to 250 feet (76.20 m) total equivalent length, up to 200 feet (60.96 m) condenser above evaporator, or up to 80 ft. (24.38 m) evaporator above condenser (See Longline Guide for more information.) S Low ambient (down to --20_F/--28.9_C) with accessory kit MODEL NUMBER NOMENCLATURE 1 N 2 N 3 A 4 A 5 A/N 6 N 7 N 8 N 9 A/N 10 A/N 11 A/N 12 N 13 N 2 5 H C E 4 3 6 A 0 0 3 0 Open Open Voltage 0=Not Defined 0=Not Defined 3=208/230/1 5=208/230/3 6=460/3 Product Series 25 = HP Product Major Tier Family Series H = RES HP C=Comfort E = Puron Cooling Capacity SEER 4=14 SEER Grille Variations A=Dense Grille Minor Series 0, 1, 2... Use of the AHRI Certified TM Mark indicates a manufacturer’s participation in the program For verification of certification for individual products, go to www.ahridirectory.org. STANDARD FEATURES Feature 18 24 30 36 42 48 60 Puron Refrigerant X X X X X X X Scroll Compressor X X X X X X X Field Installed Filter Drier X X X X X X X Front Seating Service Valves X X X X X X X Internal Pressure Relief Valve X X X X X X X Internal Thermal Overload X X X X X X X Long Line capability X X X X X X X Low Ambient capability with Kit X X X X X X X Suction Line Accumulator X X X X X X X High Pressure Switch X X X X X X X Loss of Charge Switch X X X X X X X X = Standard 2 PHYSICAL DATA UNIT SIZE SERIES 18--- 30 24--- 30 30--- 30 36--- 31, 51, 61 42--- 30 48--- 30, 50, 60 60--- 30 60--- 50, 60 Compressor Type Scroll REFRIGERANT Puron (R---410A) Control TXV (Puron Hard Shutoff) Outdoor Heating Piston # 42 46 49 57 61 65 73 78 Charge lb (kg) 5.30 (2.4) 5.60 (2.5) 6.40 (2.9) 7.67 (3.48) 8.25 (3.74) 8.68 (3.94) 10.60 (4.81) 10.60 (4.81) COND FAN Forwrard Swept or Propeller Type, Direct Drive Air Discharge Vertical Motor HP 1/12 1/10 1/4 1/5 1/4 1/4 1/4 1/4 Motor RPM 1100 1100 1100 1100 1100 1100 800 800 CFM 1700 2195 3365 3165 3800 3365 4470 4470 VALVE CONNECT. (In. ID) Vapor 5/8 5/8 3/4 3/4 7/8 7/8 7/8 7/8 Liquid 3/8 REFRIGERANT TUBES* (In. OD) Rated Vapor 5/8 5/8 3/4 3/4 7/8 7/8 1 ---1/8 1 ---1/8 Max Liquid Line 3/8 *Units are rated with 25 ft (7.6 m) of lineset length. See Vapor Line Sizing and Cooling Capacity Loss table when using other sizes and lengths of lineset. Note: See unit Installation Instruction for proper installation. VAPOR LINE SIZING AND COOLING CAPACITY LOSS Acceptable vapor line diameters provide adequate oil return to the compressor while avoiding excessive capacity loss. The suction line diameters shown in the chart below are acceptable for HP systems with Puron refrigerant: Vapor Line Sizing and Cooling Capacity Losses -- Puronr Refrigerant 1-- Stage Heat Pump Applications Unit Nominal Size (Btuh) Acceptable Vapor Line Diameters (In. OD) Cooling Capacity Loss (%) Total Equivalent Line Length (ft) Standard Application Long Line Application Requries Accessories 25 (7.62) 50 (15.2) 80 (24.4) 80+ (24.4+) 100 (30.48) 125 (38.10) 150 (45.72) 175 (53.34) 200 (60.96) 225 (68.58) 250 (76.20) 18000 1--- Stage HP 1/2 1 2 3 3 4 6 7 8 9 10 12 5/8 0 0 1 1 1 1 2 2 3 3 3 24000 1--- Stage HP 5/8 0 1 1 1 2 3 3 4 4 5 6 3/4 0 0 0 0 0 1 1 1 1 1 2 5/8 1 2 3 3 3 4 5 6 7 8 9 3/4 0 0 1 1 1 1 2 2 2 3 3 7/8 0 0 0 0 0 1 1 1 1 1 1 5/8 1 2 4 4 5 6 7 9 10 11 13 3/4 0 0 1 1 1 2 2 3 3 4 4 7/8 0 0 0 0 0 1 1 1 1 2 2 42000 1--- Stage HP 3/4 0 1 2 2 2 3 4 4 5 6 6 7/8 0 0 1 1 1 1 2 2 2 3 3 48000 1--- Stage HP 3/4 0 1 2 2 3 4 5 5 6 7 8 7/8 0 0 1 1 1 2 2 2 3 3 4 3/4 1 2 4 4 5 6 7 9 10 11 12 7/8 0 1 2 2 2 3 4 4 5 5 6 1 1/8 0 0 0 0 1 1 1 1 1 1 2 30000 1--- Stage HP 36000 1--- Stage HP 60000 1--- Stage Puron HP Standard Length = 80 ft. (24.4 m) or less total equivalent length Applications in this area are long line. Accessories are required as shown recommended on Long Line Application Guidelines Applications in this area may have height restrictions that limit allowable total equivalent length, when outdoor unit is below indoor unit See Long Line Application Guidelines 3 REFRIGERANT PIPING LENGTH LIMITATIONS Maximum Line Lengths: The maximum allowable total equivalent length for heat pumps varies depending on the vertical separation. See the tables below for allowable lengths depending on whether the outdoor unit is on the same level, above or below the outdoor unit. Maximum Line Lengths for Heat Pump Applications MAXIMUM ACTUAL LENGTH ft (m) MAXIMUM EQUIVALENT LENGTH{ ft (m) MAXIMUM VERTICAL SEPARATION ft (m) Units on equal level 200 (61) 250 (76.2) N/A Outdoor unit ABOVE indoor unit 200 (61) 250 (76.2) 200 (61) Outdoor unit BELOW indoor unit See Table ’Maximum Total Equivalent Length: Outdoor Unit BELOW Indoor Unit’ { Total equivalent length accounts for losses due to elbows or fitting. See the Long Line Guideline for details. Maximum Total Equivalent Length{ -- Outdoor Unit BELOW Indoor Unit Size Liquid Line Diameter w/ TXV 18000 HP with Puron 24000 HP with Puron 30000 HP with Puron 36000 HP with Puron 42000 HP with Puron 48000 HP with Puron 60000 HP with Puron 0--- 20 (0 --- 6.1) HP with Puronr Refrigerant --- Maximum Total Equivalent Length{ Vertical Separation ft (m) Outdoor unit BELOW indoor unit; 21--- 30 31--- 40 41--- 50 51--- 60 61--- 70 (6.4 --- 9.1) (9.4 --- 12.2) (12.5 --- 15.2) (15.5 --- 18.3) (18.6 --- 21.3) 71--- 80 (21.6 --- 24.4) 3/8 250* 250* 250* 250* 250* 250* 250* 3/8 250* 250* 250* 250* 250* 250* 250* 3/8 250* 250* 250* 250* 250* 250* 250* 3/8 250* 250* 250* 250* 250* 250* 250* 3/8 250* 250* 250* 250* 250* 250* 150 3/8 250* 250* 250* 250* 230 160 --- 3/8 250* 225* 190 150 110 --- --- * Maximum actual length not to exceed 200 ft (61 m) { Total equivalent length accounts for losses due to elbows or fitting. See the Long Line Guideline for details. --- = outside acceptable range LONG LINE APPLICATIONS An application is considered Long Line when the refrigerant level in the system requires the use of accessories to maintain acceptable refrigerant management for systems reliability. Defining a system as long line depends on the liquid line diameter, actual length of the tubing, and vertical separation between the indoor and outdoor units. For Heat Pump systems, the chart below shows when an application is considered Long Line. Beyond these lengths, long line accessories are required: HP WITH PURONr REFRIGERANT LONG LINE DESCRIPTION ft (m) Beyond these lengths, long line accessories are required Liquid Line Size Units On Same Level Outdoor Below Indoor Outdoor Above Indoor 3/8 80 (24.4) 20 (6.1) vertical or 80 (24.4) total 80 (24.4) Note: See Long Line Guideline for details 4 ACCESSORIES ORDER NUMBER DESCRIPTION Unit Size Series, Voltage 18 30 24 30 30 30 X X 36 31 36 51 36 61 HC32GE234 BALL BEARING FAN MOTOR HC34GE240 BALL BEARING FAN MOTOR HC38GE219 BALL BEARING FAN MOTOR HC40GE228 BALL BEARING FAN MOTOR KAACH1601AAA CRKC HTR KIT KAACH1701AAA CRKC HTR KIT X X X X KAACS0201PTC KIT PTC X X X X KAATD0101TDR TIME DELAY KIT X X X X X X KHAIR0201AAA ISLN RELAY KIT X X X X X KHALS0401LLS SOL VALVE KIT X X X X KHAOT0201SEC OUTDR THERM KIT X X X KHAOT0301FST OUTDR THERM KIT X X KHASS0606MPK SNOW STAND KIT X KSACY0101AAA CYCLE PROTR KIT KSAFT0101AAA 42 30 48 30 48 50 48 60 60 30 60 50 60 60 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X FRZ THERM KIT X X X X X X X X X X X X X KSAHS1701AAA HARD START KIT X X X X X X KSALA0301410 LOW AMBIENT KIT X X X X X X X X X X X KSALA0601AAA MOTORMASTER KIT X X X X X X X X X X KSALA0701AAA MOTORMASTER KIT KSASF0101AAA SPRT FEET KIT X X X X X X X X X X X KSASF0201AAA SPRT FEET KIT X X KSASH0601COP SOUND BLKT KIT X X X X X X X KSASH2101COP SOUND BLKT KIT X X X X X X KSATX0201PUR TXV KIT X X X KSATX0301PUR TXV KIT KSATX0501PUR TXV KIT X X X X X X KSBTX0201PUR TXV KIT KSBTX0301PUR TXV KIT X X X X X X X X X X X X X X X X X X x = Accessory ACCESSORY THERMOSTATS Part Number Capabilities Description Gas Electric Heat Pump Heat Stages Cooling Stages TP---WEM01 CôR™, Wi---Fi Programmable Relative Humidity Thermostat X X X 4 2 TP---PRH01 ---A edge™ Programmable Relative Humidity Thermostat X X X 3 2 TP---PHP01 edge™ Programmable Thermostat (HP or AC) X X 3 2 TP---NRH01 edge™ Non ---Programmable Relative Humidity Thermostat X X 3 2 TP---NHP01 edge™ Non ---Programmable Thermostat (HP or AC) X X 3 2 TC ---WHS01 Wi---Fi® Programmable X X 3 2 TC ---PHP01 Programmable Thermostat (HP or AC) X X 3 2 TC ---NHP01 Non ---Programmable Thermostat (HP or AC) X X 3 2 TB---PHP01 Programmable Thermostat (HP or AC) X X 2 1 TB---NHP01 Non ---Programmable Thermostat (HP or AC) X X 2 1 X X Thermostat Accessories Part Number Description TP---EXP EXP Card for Programmable Thermostats TSTATXXCNV10 Thermostat Conversion Kit (4 to 5 wire) 10 pack TX ---LBP01 Large Decorative Backplate TX ---MBP01 Medium Decorative Backplate TX ---SBP01 Small Decorative Backplate Used With TP---Pxx All Carrier branded thermostats TP---Pxx, TP---Nxx, TC ---Pxx TC ---Nxx, TB---Pxx TB---Nxx 5 ACCESSORY USAGE GUIDELINE Standard No} REQUIRED FOR SEA COAST APPLICATIONS (Within 2 miles / 3.22 km) Standard No} Yes** Yes** No** Crankcase Heater Yes} Yes} No} Evaporator Freeze Thermostat Hard Shutoff TXV Isolation Relay Liquid Line Solenoid Valve Motor Master Control or Low Ambient Switch Support Feet Yes Yes Yes No No Yes No See Long---Line Application Guideline No No No No Yes No No Recommended No Recommended Accessory Accumulator Ball Bearing Fan Motor Compressor Start Assist Capacitor and Relay REQUIRED FOR LOW --- AMBIENT COOLING APPLICATIONS (Below 55F / 12.8C) Standard Yes{ REQUIRED FOR LONG LINE APPLICATIONS* * For tubing line sets between 80 and 200 ft. (24.38 and 60.96 m) and/or 20 ft. (6.09 m) vertical differential, refer to Residential Split---System Longline Application Guideline. { Additional requirement for Low---Ambient Controller (full modulation feature) MotorMasterr Control. } Standard for 3 phase units only ** Not required for 3 ---phase units. Accessory Description and Usage (Listed Alphabetically) 1. Ball--Bearing Fan Motor A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication. Usage Guideline: Required on all units when using MotorMasterr 2. Compressor Start Assist -- Capacitor and Relay Start capacitor and relay gives a hard boost to compressor motor at each start up. Usage Guideline: Required for reciprocating compressors in the following applications: Long line Low ambient cooling Hard shut off expansion valve on indoor coil Liquid line solenoid on indoor coil Required for single--phase scroll compressors in the following applications: Long line Low ambient cooling Suggested for all compressors in areas with a history of low voltage problems. 3. Compressor Start Assist — PTC Type Solid state electrical device which gives a soft boost to the compressor at each start--up. Usage Guideline: Suggested for single phase unit installations with marginal power supply. 4. Crankcase Heater An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication on restart and minimizes the chance of liquid slugging. Usage Guideline: Required in low ambient cooling applications. Required in long line applications. Suggested in all commercial applications. 5. Evaporator Freeze Thermostat An SPST temperature--actuated switch that stops unit operation when evaporator reaches freeze--up conditions. Usage Guideline: Required when low ambient kit has been added. 6. Isolation Relay An SPDT relay which switches the low--ambient controller out of the outdoor fan motor circuit when the heat pump switches to heating mode. Usage Guideline: Required in all heat pumps where low ambient kit has been added. 7. Liquid--Line Solenoid Valve (LLS) An electrically operated shutoff valve which stops and starts refrigerant liquid flow in response to compressor operation. It is to be installed at the outdoor unit to control refrigerant off cycle migration in the heating mode. Usage Guideline: An LLS is required in all long line heat pump applications to control refrigerant off cycle migration in the heating mode. See Long Line Guideline. 8. Low--Ambient Pressure Switch Kit A long life pressure switch which is mounted to outdoor unit service valve. It is designed to cycle the outdoor fan motor in order to maintain head pressure within normal operating limits. The control will maintain working head pressure at low--ambient temperatures down to 0_F (--18_C) when properly installed. Usage Guideline: A Low--Ambient Pressure Switch or MotorMasterr Low--Ambient Controller must be used when cooling operation is used at outdoor temperatures below 55_F (12.8_C). 9. MotorMasterr Low--Ambient Controller A fan--speed control device activated by a temperature sensor, designed to control condenser fan motor speed in response to the saturated, condensing temperature during operation in cooling mode only. For outdoor temperatures down to --20_F (--28.9_C), it maintains condensing temperature at 100_F 10_F (37.8_C 6.5_C). Usage Guideline: A MotorMasterr Low Ambient Controller or Low--Ambient Pressure Switch must be used when cooling operation is used at outdoor temperatures below 55_F (12.8_C). Suggested for all commercial applications. 6 Accessory Description and Usage (Listed Alphabetically) -- CONTINUED 10. Outdoor Air Temperature Sensor Designed for use with Carrier Thermostats listed in this publication. This device enables the thermostat to display the outdoor temperature. This device also is required to enable special thermostat features such as auxiliary heat lock out. Usage Guideline: Suggested for all Carrier thermostats listed in this publication. 11. Outdoor Thermostat An SPDT temperature--actuated switch which turns on supplemental electric heaters when outdoor air temperature drops below a user--selected set point. Usage Guideline: Electric supplemental heat applications in non--variable speed indoor units when electric heat staging is desired. 12. Secondary Outdoor Thermostat An SPDT temperature--actuated switch which turns on third--stage of supplemental electric heaters when outdoor air temperature drops below the second--stage set point. Usage Guideline: Outdoor thermostat applications where electric heater is capable of 3--stage operation. 13. Snow Stand Rack Coated wire rack which supports unit 18 in. (457.2 mm) above mounting pad to allow for drainage from unit base. Usage Guideline: Suggested in the following applications: Heat pump installations in heavy snowfall areas. Heat pump installations in snow drift locations. Heat pump installations in areas of prolonged subfreezing temperatures. All commercial installations. 14. Sound Hood Wraparound sound reducing cover for the compressor. Reduces the sound level by about 2 dBA. Usage Guideline: Suggested when unit is installed closer than 15 ft. (4.577 m) to quiet areas, bedrooms, etc. Suggested when unit is installed between two houses less than 10 ft. (3.05 m) apart. 15. Thermostatic Expansion Valve (TXV) Bi--Flow A modulating flow--control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the evaporator. Usage Guideline: Accessory required to meet AHRI rating and system reliability, where indoor not equipped. Required in all heat pump applications designed with Puron refrigerant. 16. Time--Delay Relay An SPST delay relay which briefly continues operation of indoor blower motor to provide additional cooling after the compressor cycles off. Note: Most indoor unit controls include this feature. For those that do not, use the guideline below. Usage Guideline: Accessory required to meet AHRI rating, where indoor not equipped. 7 ELECTRICAL DATA UNIT SIZE V/PH OPER VOLTS* MAX COMPR MIN FAN LRA RLA MAX FUSE** or CKT BRK AMPS 20 25 30 30 40 40 50 20 25 30 15 15 15 MCA FLA 18 --- 30 48.0 9.00 0.50 11.8 24 --- 30 62.9 10.90 0.60 14.2 30 --- 30 72.5 13.50 1.40 18.3 36 --- 31 208/230/1 253 197 75.0 15.10 1.10 20.0 42 --- 30 105.5 18.10 1.40 24.0 48 --- 30 108.0 19.00 1.40 25.2 60 --- 30 144.2 24.40 1.52 32.0 36 --- 51 70.0 8.46 1.10 11.7 48 --- 50 208/230/3 253 187 123.0 10.44 1.40 14.5 60 --- 50 110.0 15.96 1.52 21.5 36 --- 61 31.0 3.85 0.60 5.4 48 --- 60 460 ---3 506 414 60.0 6.00 0.77 8.3 60 --- 60 52.0 7.75 0.77 10.5 * Permissible limits of the voltage range at which the unit will operate satisfactorily ** Time ---Delay fuse. FLA --- Full Load Amps LRA --- Locked Rotor Amps MCA --- Minimum Circuit Amps RLA --- Rated Load Amps NOTE: Control circuit is 24 ---V on all units and requires external power source. Copper wire must be used from service disconnect to unit. All motors/compressors contain internal overload protection. Complies with 2007 requirements of ASHRAE Standards 90.1 A--WEIGHTED SOUND POWER UNIT SIZE 18--- 30 24--- 30 30--- 30 36--- 31, 51, 61 42--- 30 48--- 30, 50, 60 60--- 30 60--- 50, 60 STANDARD RATING (dBA) 69 76 77 77 76 79 73 76 TYPICAL OCTAVE BAND SPECTRUM (dBA, without tone adjustment) 125 250 500 1000 2000 4000 8000 45 46 52 51 49 53 50 52 48 56 62 62 61 66 63 62 56 59 67 66 63 69 62 63 62 63 68 69 65 71 63 66 55 63 65 64 62 67 60 65 53 60 62 61 60 64 58 59 47 55 55 53 52 57 52 57 NOTE: Tested in accordance with AHRI Standard 270 ---08 (not listed in AHRI). A--WEIGHTED SOUND POWER WITH SOUND HOOD UNIT SIZE 18--- 30 24--- 30 30--- 30 36--- 31, 51, 61 42--- 30 48--- 30, 50, 60 60--- 30 60--- 50, 60 STANDARD RATING 68 74 77 76 74 79 73 76 125 47 47 52 52 50 54 51 52 TYPICAL OCTAVE BAND SPECTRUM (dBA, without tone adjustment) 250 500 1000 2000 4000 48 56 61 55 52 57 59 62 61 58 62 67 67 65 62 62 66 67 64 60 61 63 64 61 58 66 69 70 67 64 64 62 63 59 56 62 63 66 65 59 8000 46 51 54 52 49 56 49 57 NOTE: Tested in accordance with AHRI Standard 270 ---08 (not listed in AHRI). CHARGING SUBCOOLING (TXV--TYPE EXPANSION DEVICE) UNIT SIZE --- SERIES 18--- 30 24--- 30 30--- 30 36--- 31 36--- 51, 61 42--- 30 48--- 30, 50, 60 60--- 30, 50, 60 REQUIRED SUBCOOLING ° F (° C) 11 (6.1) 11 (6.1) 10 (5.6) 10 (5.6) 11 (6.1) 10 (5.6) 14 (7.8) 15 (8.3) HP ONLY REPLACEMENT WITH PISTON INDOORS When the 25HCE4 is used as a replacement component in a system with a piston fan coil, use the indoor piston size specified below: UNIT SIZE 18 24 30 36 42 48 60 PISTON SIZE FFM 0.050 0.057 0.070 0.072 FB4CNF 0.052 0.057 0.067 0.070 0.078 0.084 = N/A 8 FPMA 0.050 0.056 0.067 0.069 9 0 0 0 1 1 1 0 0 0 0 0 0 0 25HCE418A0030011 25HCE424A0030011 25HCE430A0030011 25HCE436A0031011 25HCE436A0051011 25HCE436A0061011 25HCE442A0030011 25HCE448A0030011 25HCE448A0050011 25HCE448A0060011 25HCE460A0030011 25HCE460A0050011 25HCE460A0060011 18 24 30,36,42,48,60 - UNIT SIZE SERIES UNIT 792.5 31 3/16 Y=YES N=NO N 23 1/8 25 3/4 31 3/16 35 "X" 587.3 654.0 792.5 889.0 MINIMUM GROUND MOUNTING PAD APPLICATION DIMENSIONS Y N N INCH 17 20 22 26 7/8 7/16 15/16 3/4 "Y" 32 1/16 32 1/16 32 1/16 28 11/16 28 11/16 28 11/16 38 7/8 28 11/16 28 11/16 28 11/16 32 1/16 35 1/2 35 1/2 B MM 815.1 815.1 815.1 728.7 728.7 728.7 987.8 728.7 728.7 728.7 815.1 901.4 902.0 454.6 518.5 583.2 679.7 MINIMUM ROOF-TOP MOUNTING PAD APPLICATION DIMENSIONS 792.5 31 3/16 N N 792.5 31 3/16 N N 792.5 31 3/16 N 792.5 Y 792.5 31 3/16 N N 31 3/16 N N 792.5 31 3/16 N N 792.5 31 3/16 N Y 792.5 31 3/16 N N 792.5 31 3/16 N 792.5 N 654.0 31 3/16 N N 25 3/4 N N MM 587.3 INCH A 23 1/8 N N 208-230-1-60 Y N N Y N N N Y N N N N 460-3-60 208/230-3-60 N Y N N Y Y N N Y Y Y Y ELECTRICAL CHARACTERISTICS DIMENSIONS 575-3-60 7/8 7/8 7/8 7/8 7/8 7/8 7/8 3/4 3/4 3/4 3/4 5/8 5/8 INCH C MM 22.2 22.2 22.2 22.2 22.2 22.2 22.2 19.1 19.1 19.1 19.1 15.9 15.9 INCH 6 9/16 6 9/16 6 9/16 6 9/16 6 9/16 6 9/16 6 9/16 6 9/16 6 9/16 6 9/16 6 9/16 4 7/16 4 7/16 D MM 166.1 166.1 166.1 166.1 166.1 166.1 166.1 166.1 166.1 166.1 166.1 113.0 113.0 INCH MM 626.3 626.3 626.3 626.3 626.3 626.3 626.3 626.3 626.3 626.3 626.3 539.9 459.0 INCH 9 1/8 9 1/8 9 1/8 9 1/8 9 1/8 9 1/8 9 1/8 9 1/8 9 1/8 9 1/8 9 1/8 9 1/8 7 13/16 F MM 231.3 231.3 231.3 231.3 231.3 231.3 231.3 231.3 231.3 231.3 231.3 231.3 197.9 INCH 1 1/8 1 1/8 1 1/8 1 1/8 1 1/8 1 1/8 1 1/8 1 1/8 1 1/8 1 1/8 1 1/8 1 1/8 1 1/8 G MM 28.2 28.2 28.2 28.2 28.2 28.2 28.2 28.2 28.2 28.2 28.2 28.2 28.2 INCH 3 13/16 3 13/16 3 13/16 3 13/16 3 13/16 3 13/16 3 13/16 3 13/16 3 13/16 3 13/16 3 13/16 3 13/16 3 13/16 NOTE: ALL DIMENSIONS IN INCH (MM) 24 11/16 24 11/16 24 11/16 24 11/16 24 11/16 24 11/16 24 11/16 24 11/16 24 11/16 24 11/16 24 11/16 21 1/4 18 1/16 E H MM 97.4 97.4 97.4 97.4 97.4 97.4 97.4 97.4 97.4 97.4 97.4 97.4 97.4 INCH 33 3/8 33 3/8 33 3/8 33 3/8 33 3/8 33 3/8 33 3/8 33 3/8 33 3/8 33 3/8 33 3/8 27 7/8 25 1/4 I MM 847.7 847.7 847.7 847.7 847.7 847.7 847.7 847.7 847.7 847.7 847.7 708.0 641.4 INCH MM 847.7 847.7 847.7 847.7 847.7 847.7 847.7 847.7 847.7 847.7 847.7 708.0 641.4 36 5/8 36 5/8 36 5/8 33 1/4 33 1/4 33 1/4 43 1/2 33 1/4 33 1/4 33 1/4 36 5/8 40 40 INCH K MM 930.3 930.3 930.3 844.6 844.6 844.6 1104.9 844.6 844.6 844.6 930.3 1016.0 1016.0 212 212 212 197 197 197 201 170 170 170 158 144 136 Lbs 96.2 96.2 96.2 89.4 89.4 89.4 91.2 77.1 77.1 77.1 71.7 65.3 61.7 Kgs OPERATING WEIGHT 248 248 248 232 232 232 235 201 201 201 180 175 166 Lbs 112.5 112.5 112.5 105.2 105.2 105.2 106.6 91.2 91.2 91.2 81.6 79.4 75.3 Kgs SHIPPING WEIGHT U.S. ECCN: Not Subject to Regulation (N.S.R.) 33 3/8 33 3/8 33 3/8 33 3/8 33 3/8 33 3/8 33 3/8 33 3/8 33 3/8 33 3/8 33 3/8 27 7/8 25 1/4 J 33 5/16 33 5/16 33 5/16 33 5/16 33 5/16 33 5/16 33 5/16 33 5/16 33 5/16 33 5/16 33 5/16 27 7/8 25 1/4 36 5/8 36 5/8 36 5/8 33 3/16 33 3/16 33 3/16 43 3/8 33 3/16 33 3/16 33 3/16 36 5/8 40 40 INCH 929.5 929.5 929.5 843.1 843.1 843.1 1102.2 843.1 843.1 843.1 929.5 1015.8 1015.8 MM SHIPPING HEIGHT SD5367-4 REV. B 846.6 846.6 846.6 846.6 846.6 846.6 846.6 846.6 846.6 846.6 846.6 708.2 641.5 SHIPPING LENGTH / WIDTH (Sq.) INCH MM 10 24” (609.6) Service 12” (304.8) Note: Numbers in ( ) = mm 18” (457.2) 24” (609.6) Service Wall 6” (152.4) 18” (457.2) 12” (304.8) 24” (609.6) Service Wall 18” (457.2) 12” (304.8) Clearances (various examples) 24” (609.6) Service 12” (304.8) 24” (609.6) Service Wall 6” (152.4) IMPORTANT: When installing multiple units in an alcove, roof well, or partially enclosed area, ensure there is adequate ventilation to prevent re--circulation of discharge air. CLEARANCES Wall 11 0 0 BUILDING HEAT LOSS, UNIT INTEGRATED HEATING CAPACITY, MBTUH C F 0 10 20 30 40 50 60 70 80 -23.3 -10.0 -17.8 0.0 BALANCE POINT WORKSHEET -12.2 10.0 -6.7 20.0 4.4 40.0 OUTDOOR TEMPERATURE -1.1 30.0 25HCE442 10.0 50.0 15.6 60.0 21.1 70.0 BASED ON INDOOR ENTERING AIR AT 70◦F (21.1◦C) AND AT RATED CFM 25HCE418 FB4CNP018L 25HCE424 FB4CNP030L 25HCE430 FB4CNP030L 25HCE436 FB4CNP036L FB4CNP042L 80.0 26.7 0.0 2.9 5.9 8.8 11.7 14.6 17.6 FB4CNP048L 25HCE448 20.5 25HCE460 FX4DNF061L 23.4 kW TESTED AHRI COMBINATION RATINGS NOTE: Ratings contained in this document are subject to change at any time. For AHRI ratings certificates, please refer to the AHRI directory www.ahridirectory.org Additional ratings and system combinations can be accessed via the Carrier database at: www.MyCarrierRatings.com For performance data at specific application &/or design conditions with various indoor unit combinations, the equipment performance calculator can be accessed at : http://rpmob.wrightsoft.com/ High Temp Model Number Indoor Coil Model Number Cooling Capacity EER SEER E Capacity E COP 25HCE418A**30 FB4CNP018L 17,800 11.7 14 17,600 25HCE424A**30 FB4CNP030L 22,200 11.5 14 22,200 25HCE430A**30 FB4CNP030L 28,600 11.7 14 25HCE436A**31 FB4CNP036L 33,000 11.7 25HCE436A**51, 61 FB4CNP036L 33,000 25HCE442A**30 FB4CNP042L 25HCE448A**30, 50, 60 25HCE460A**30, 50, 60 Low Temp HSPF H Capacity H COP 3.72 8.2 10,400 2.40 3.84 8.2 13,200 2.54 28,600 3.62 8.2 17,100 2.44 14 33,800 3.62 8.2 21,000 2.40 11.0 14 33,000 3.64 8.2 20,800 2.46 40,000 11.5 14 41,000 3.62 8.2 25,200 2.50 FB4CNP048L 46,000 11.7 14 45,500 3.64 8.2 27,800 2.56 FX4DN(B,F)061L 57,000 11.7 14 54,500 3.70 8.2 33,000 2.56 Cooling Standard: 80_F (27_C) db 67_F (19_C) wb indoor entering air temperature and 95_F (35_C) db air entering outdoor unit. High---Temp Heating Standard: 70_F (21_C) db indoor entering air temperature and 47_F (8_C) db 43° F (6_C) wb air entering outdoor unit. Low---Temp Heating Standard: 70_F (21_C) db indoor entering air temperature and 17_F (---8_C) db 15° F (---9_C) wb air entering outdoor unit. COP — Coefficient of Performance EER — Energy Efficiency Ratio HSPF — Heating Seasonal Performance Factor SEER — Seasonal Energy Efficiency Ratio 12 13 72 (22.2) 67 (19.4) 63 (17.2)†† 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 63 (17.2)†† 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 63 (17.2)†† 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 63 (17.2)†† 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 63 (17.2)†† 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 63 (17.2)†† 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 63 (17.2)†† 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 63 (17.2)†† 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 63 (17.2)†† 62 (16.7) 57 (13.9) EWB ° F (° C) See notes on page 15 1125 1050 875 CFM EVAPORATOR AIR 900 800 700 CFM EWB ° F (° C) EVAPORATOR AIR 675 600 525 CFM EWB ° F (° C) EVAPORATOR AIR 75 (23.9) 10.44 12.77 12.27 15.03 16.97 10.96 13.61 13.06 16.13 17.73 11.46 14.41 13.81 17.11 18.36 Sens‡ 75 (23.9) 13.51 16.68 16.04 19.75 21.31 14.20 17.79 17.07 21.17 22.20 14.86 18.85 18.05 22.97 22.94 Sens‡ 33.97 30.80 28.51 27.99 27.05 34.85 31.61 29.28 28.88 28.55 35.15 31.89 29.55 29.18 29.10 Total 17.32 21.30 20.46 25.15 27.05 18.48 23.17 22.21 27.53 28.55 18.97 23.96 22.94 29.18 29.10 Sens‡ Capacity MBtuh 26.47 24.06 22.32 21.92 21.31 26.97 24.53 22.77 22.45 22.20 27.35 24.89 23.12 22.97 22.94 Total Capacity MBtuh 21.43 19.44 17.99 17.64 16.97 21.88 19.86 18.40 18.08 17.73 22.22 20.19 18.71 18.48 18.36 Total Capacity MBtuh 75 (23.9) 1.97 1.97 1.97 1.97 1.97 2.00 2.01 2.01 2.01 2.01 2.02 2.02 2.03 2.03 2.03 Total Syst. KW** 1.53 1.53 1.53 1.53 1.54 1.55 1.55 1.55 1.55 1.55 1.56 1.57 1.57 1.57 1.57 Total Syst. KW** 1.20 1.19 1.19 1.19 1.19 1.21 1.20 1.20 1.20 1.20 1.22 1.22 1.21 1.21 1.21 Total Syst. KW** 85 (29.4) 85 (29.4) 10.06 12.39 11.90 14.64 16.30 10.58 13.22 12.67 15.71 17.01 11.07 14.01 13.41 17.63 17.60 Sens‡ 85 (29.4) 13.08 16.24 15.60 19.28 20.52 13.76 17.34 16.62 21.27 21.35 14.41 18.38 17.59 22.08 22.05 Sens‡ 32.47 29.42 27.22 26.74 26.06 33.25 30.15 27.91 27.62 27.48 33.53 30.39 28.15 28.02 27.98 Total 16.75 20.72 19.89 24.55 26.06 17.90 22.59 21.62 27.37 27.48 18.39 23.37 22.34 28.02 27.98 Sens‡ Capacity MBtuh 25.28 22.96 21.30 20.94 20.52 25.73 23.38 21.70 21.45 21.35 26.08 23.71 22.02 22.08 22.05 Total Capacity MBtuh 20.38 18.48 17.10 16.78 16.30 20.77 18.86 17.47 17.20 17.01 21.08 19.15 17.75 17.63 17.60 Total Capacity MBtuh DETAILED COOLING CAPACITIES# Total Total Capacity MBtuh Capacity MBtuh Syst. Syst. Total Sens‡ Total Sens‡ KW** KW** 25HCE430---30 Outdoor Section With FB4CNP030L Indoor Section 2.17 30.87 16.16 2.40 29.15 15.54 2.17 27.96 20.13 2.40 26.39 19.50 2.17 25.86 19.29 2.41 24.39 18.66 2.17 25.44 23.90 2.41 24.07 23.17 2.18 25.01 25.01 2.41 23.88 23.88 2.21 31.57 17.30 2.44 29.76 16.66 2.21 28.60 21.97 2.44 26.95 21.32 2.21 26.47 21.00 2.45 24.94 20.34 2.21 26.36 26.36 2.45 25.12 25.12 2.21 26.33 26.33 2.45 25.09 25.09 2.23 31.81 17.78 2.46 29.96 17.13 2.23 28.82 22.74 2.46 27.14 22.07 2.23 26.69 21.71 2.46 25.12 21.03 2.23 26.83 26.83 2.46 25.55 25.55 2.23 26.80 26.80 2.46 25.52 25.52 CONDENSER ENTERING AIR TEMPERATURES ° F (° C) 95 (35) 105 (40.6) Total Total Capacity MBtuh Capacity MBtuh Syst. Syst. Total Sens‡ Total Sens‡ KW** KW** 25HCE424---30 Outdoor Section With FB4CNP030L Indoor Section 1.71 24.03 12.62 1.91 22.72 12.15 1.71 21.82 15.78 1.91 20.62 15.31 1.72 20.23 15.14 1.92 19.11 14.66 1.72 19.93 18.78 1.92 18.88 18.78 1.72 19.70 19.70 1.92 18.81 18.81 1.72 24.44 13.30 1.92 23.07 12.82 1.73 22.20 16.87 1.93 20.95 16.38 1.73 20.60 16.15 1.94 19.43 15.65 1.73 20.50 20.50 1.94 19.55 19.55 1.73 20.47 20.47 1.94 19.53 19.53 1.74 24.73 13.94 1.94 23.33 13.46 1.75 22.49 17.91 1.95 21.20 17.40 1.75 20.88 17.10 1.96 19.68 16.59 1.75 21.14 21.14 1.95 20.14 20.14 1.75 21.11 21.11 1.95 20.12 20.12 CONDENSER ENTERING AIR TEMPERATURES ° F (° C) 95 (35) 105 (40.6) Total Total Capacity MBtuh Capacity MBtuh Syst. Syst. Total Sens‡ Total Sens‡ KW** KW** 25HCE418---30 Outdoor Section With FB4CNP018L Indoor Section 1.36 19.27 9.66 1.54 18.10 9.26 1.36 17.47 11.99 1.53 16.40 11.58 1.35 16.16 11.50 1.53 15.16 11.08 1.35 15.88 14.22 1.53 14.93 13.76 1.35 15.58 15.58 1.52 14.81 14.81 1.38 19.62 10.18 1.56 18.40 9.76 1.37 17.80 12.82 1.55 16.69 12.39 1.36 16.49 12.27 1.54 15.44 11.84 1.36 16.27 16.27 1.54 15.43 15.43 1.36 16.24 16.24 1.54 15.41 15.41 1.39 19.88 10.66 1.57 18.63 10.24 1.38 18.06 13.60 1.56 16.91 13.16 1.38 16.74 12.99 1.56 15.66 12.55 1.38 16.80 16.80 1.56 15.93 15.93 1.38 16.78 16.78 1.56 15.91 15.91 CONDENSER ENTERING AIR TEMPERATURES ° F (° C) 95 (35) 105 (40.6) 2.67 2.67 2.67 2.67 2.67 2.71 2.71 2.71 2.71 2.71 2.73 2.73 2.73 2.73 2.73 Total Syst. KW** 2.14 2.15 2.16 2.16 2.16 2.16 2.16 2.17 2.17 2.17 2.17 2.18 2.19 2.19 2.19 Total Syst. KW** 1.74 1.73 1.73 1.73 1.73 1.76 1.75 1.74 1.74 1.74 1.77 1.76 1.75 1.76 1.75 Total Syst. KW** 115 (46.1) 115 (46.1) 8.83 11.15 10.65 14.00 13.98 9.33 11.95 11.39 14.54 14.52 9.80 12.71 12.09 14.99 14.97 Sens‡ 115 (46.1) 11.65 14.80 14.15 17.88 17.86 12.31 15.86 15.13 18.53 18.51 12.94 16.86 16.05 19.07 19.04 Sens‡ 27.30 24.69 22.82 22.67 22.64 27.81 25.18 23.29 23.77 23.74 27.99 25.34 23.45 24.15 24.13 Total 14.87 18.82 17.98 22.67 22.64 15.97 20.61 19.63 23.77 23.74 16.44 21.35 20.30 24.15 24.13 Sens‡ Capacity MBtuh 21.30 19.33 17.91 17.88 17.86 21.60 19.61 18.19 18.53 18.51 21.82 19.84 18.41 19.07 19.04 Total Capacity MBtuh 16.86 15.26 14.10 14.00 13.98 17.12 15.51 14.34 14.54 14.52 17.31 15.70 14.53 14.99 14.97 Total Capacity MBtuh 2.98 2.98 2.97 2.97 2.97 3.02 3.02 3.01 3.01 3.01 3.03 3.03 3.03 3.03 3.03 Total Syst. KW** 2.41 2.42 2.42 2.42 2.42 2.43 2.43 2.44 2.44 2.44 2.44 2.45 2.46 2.45 2.45 Total Syst. KW** 1.97 1.96 1.95 1.95 1.95 1.98 1.97 1.97 1.97 1.97 2.00 1.99 1.98 1.98 1.98 Total Syst. KW** 125 (51.7) 125 (51.7) 8.39 10.69 10.19 13.10 13.08 8.88 11.48 10.92 13.59 13.57 9.35 12.22 11.59 13.99 13.97 Sens‡ 125 (51.7) 11.11 14.25 13.60 16.83 16.81 11.76 15.29 14.56 17.41 17.39 12.38 16.26 15.45 17.88 17.86 Sens‡ 25.29 22.86 21.12 21.30 21.27 25.71 23.27 21.52 22.28 22.26 25.85 23.41 21.66 22.63 22.60 Total 14.15 18.10 17.25 21.30 21.27 15.24 19.84 18.86 22.28 22.26 15.70 20.56 19.51 22.63 22.60 Sens‡ Capacity MBtuh 19.77 17.93 16.62 16.83 16.81 20.01 18.18 16.86 17.41 17.39 20.18 18.37 17.05 17.88 17.86 Total Capacity MBtuh 15.56 14.06 12.98 13.10 13.08 15.77 14.27 13.19 13.59 13.57 15.92 14.44 13.35 13.99 13.97 Total Capacity MBtuh 3.33 3.32 3.32 3.32 3.32 3.37 3.36 3.36 3.36 3.36 3.38 3.38 3.38 3.38 3.38 Total Syst. KW** 2.72 2.72 2.73 2.73 2.73 2.74 2.74 2.75 2.74 2.74 2.75 2.76 2.77 2.76 2.76 Total Syst. KW** 2.22 2.21 2.20 2.20 2.20 2.23 2.22 2.21 2.22 2.22 2.25 2.23 2.23 2.23 2.23 Total Syst. KW** 14 72 (22.2) 67 (19.4) 63 (17.2)†† 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 63 (17.2)†† 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 63 (17.2)†† 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 63 (17.2)†† 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 63 (17.2)†† 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 63 (17.2)†† 62 (16.7) 57 (13.9) EWB 72 (22.2) 67 (19.4) 63 (17.2)†† 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 63 (17.2)†† 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 63 (17.2)†† 62 (16.7) 57 (13.9) See notes on page 15 1575 1400 1225 CFM EWB ° F (° C) EVAPORATOR AIR 1350 1200 1050 CFM EVAPORATOR AIR 1350 1200 1050 CFM EWB ° F (° C) EVAPORATOR AIR 75 (23.9) 20.36 25.19 24.23 29.85 31.63 21.34 26.77 25.70 31.85 32.83 22.25 28.29 27.11 33.95 33.84 Sens‡ 75 (23.9) 19.74 24.26 23.27 28.60 31.37 20.71 25.81 24.71 30.56 32.63 21.62 27.29 26.09 31.77 33.70 Sensĕ 48.18 43.90 40.78 40.02 38.47 49.11 44.77 41.63 40.95 40.07 49.81 45.44 42.28 41.76 41.40 Total 24.31 29.85 28.76 35.22 38.47 25.48 31.73 30.52 37.70 40.07 26.57 33.53 32.19 39.89 41.40 Sens‡ Capacity MBtuh 39.66 35.85 33.11 32.50 31.37 40.44 36.57 33.79 33.27 32.63 41.05 37.13 34.33 34.11 33.70 Total Capacity MBtuh 39.42 35.87 33.28 32.68 31.63 40.13 36.53 33.92 33.39 32.83 40.68 37.04 34.40 33.95 33.84 Total Capacity MBtuh 75 (23.9) 2.78 2.81 2.83 2.83 2.84 2.81 2.84 2.86 2.86 2.87 2.84 2.87 2.89 2.89 2.90 Total Syst. KW** 2.31 2.28 2.27 2.27 2.26 2.36 2.33 2.32 2.31 2.31 2.40 2.38 2.36 2.36 2.36 Total Syst. KW** 2.23 2.24 2.25 2.25 2.26 2.27 2.28 2.29 2.29 2.29 2.31 2.32 2.33 2.33 2.33 Total Syst. KW** 85 (29.4) 19.67 24.50 23.54 29.12 30.46 20.63 26.07 25.00 31.02 31.58 21.53 27.57 26.38 32.55 32.51 Sens‡ 85 (29.4) 19.07 23.58 22.59 27.88 30.16 20.03 25.10 24.02 29.74 31.36 20.92 26.58 25.37 32.43 32.36 Sensĕ 46.14 42.03 39.02 38.32 37.12 46.98 42.82 39.80 39.20 38.63 47.60 43.41 40.38 39.97 39.89 Total 23.54 29.07 27.98 34.41 37.12 24.70 30.94 29.72 36.82 38.63 25.78 32.72 31.38 39.97 39.89 Sens‡ Capacity MBtuh 37.83 34.17 31.53 31.00 30.16 38.54 34.82 32.16 31.74 31.36 39.08 35.32 32.62 32.43 32.36 Total Capacity MBtuh 37.61 34.23 31.76 31.22 30.46 38.25 34.82 32.33 31.89 31.58 38.72 35.25 32.75 32.55 32.51 Total Capacity MBtuh 85 (29.4) 3.10 3.09 3.08 3.08 3.08 3.14 3.13 3.13 3.12 3.12 3.19 3.17 3.17 3.17 3.17 Total Syst. KW** Total Capacity MBtuh Syst. Total Sens‡ KW** 25HCE442---30 Outdoor Section With 3.12 43.91 22.72 3.13 40.00 28.24 3.14 37.15 27.15 3.14 36.51 33.54 3.14 35.68 35.68 3.15 44.64 23.85 3.17 40.70 30.10 3.17 37.83 28.87 3.18 37.36 35.82 3.18 37.09 37.09 3.18 45.20 24.93 3.20 41.22 31.85 3.21 38.36 30.51 3.21 38.30 38.30 3.21 38.25 38.25 Total Capacity MBtuh Syst. Total Sens‡ KW** FB4CNP042L Indoor Section 3.47 41.39 21.79 3.48 37.70 27.31 3.48 35.01 26.22 3.48 34.48 32.52 3.48 34.03 34.03 3.51 42.03 22.91 3.51 38.30 29.14 3.52 35.61 27.92 3.52 35.36 35.36 3.52 35.31 35.31 3.54 42.49 23.97 3.55 38.75 30.88 3.55 36.06 29.53 3.55 36.41 36.41 3.55 36.36 36.36 CONDENSER ENTERING AIR TEMPERATURES ° F (° C) 95 (35) 105 (40.6) 3.89 3.88 3.88 3.88 3.88 3.92 3.92 3.92 3.92 3.92 3.96 3.96 3.96 3.96 3.96 Total Syst. KW** CONDENSER ENTERING AIR TEMPERATURES ° F (° C) 95 (35) 105 (40.6) Total Total Total Capacity MBtuh Capacity MBtuh Syst. Syst. Syst. Total Sensĕ Total Sensĕ KW** KW** KW** 25HCE436--- 51, 61 Outdoor Section With FB4CNP036L Indoor Section 2.57 35.94 18.39 2.85 33.94 17.67 3.16 2.54 32.42 22.88 2.82 30.58 22.15 3.12 2.53 29.89 21.88 2.80 28.15 21.14 3.11 2.52 30.50 24.41 2.82 27.81 26.23 3.10 2.52 28.89 28.89 2.80 27.56 27.56 3.10 2.62 36.56 19.32 2.90 34.49 18.60 3.21 2.59 33.00 24.40 2.87 31.10 23.65 3.17 2.57 30.43 23.29 2.85 28.65 22.53 3.15 2.57 30.10 30.10 2.85 28.63 28.63 3.15 2.57 30.01 30.01 2.85 28.59 28.59 3.15 2.67 37.03 20.21 2.95 34.89 19.47 3.26 2.64 33.44 25.84 2.92 31.48 25.07 3.22 2.62 30.86 24.62 2.89 28.85 23.76 3.18 2.62 30.99 30.99 2.90 29.49 29.49 3.20 2.62 30.95 30.95 2.90 29.46 29.46 3.20 Total Capacity MBtuh Syst. Total Sens‡ KW** FB4CNP036L Indoor Section 2.79 33.63 18.20 2.78 30.59 23.01 2.77 28.38 22.05 2.77 28.03 27.40 2.77 27.82 27.82 2.83 34.10 19.12 2.82 31.03 24.54 2.82 28.81 23.47 2.82 28.80 28.80 2.82 28.77 28.77 2.87 34.45 20.01 2.86 31.35 25.98 2.86 29.12 24.79 2.86 29.57 29.57 2.86 29.54 29.54 CONDENSER ENTERING AIR TEMPERATURES ° F (° C) 95 (35) 105 (40.6) Total Capacity MBtuh Syst. Total Sens‡ KW** 25HCE436---31 Outdoor Section With 2.50 35.70 18.96 2.50 32.48 23.78 2.50 30.14 22.82 2.50 29.67 28.32 2.50 29.20 29.20 2.54 36.25 19.90 2.54 33.00 25.34 2.54 30.64 24.26 2.54 30.31 30.31 2.54 30.24 30.24 2.58 36.66 20.80 2.58 33.37 26.81 2.58 31.00 25.62 2.58 31.13 31.13 2.58 31.10 31.10 DETAILED COOLING CAPACITIES# CONTINUED 115 (46.1) 115 (46.1) 17.37 22.17 21.21 26.31 26.28 18.28 23.67 22.59 27.16 27.13 19.15 25.07 23.87 27.85 27.82 Sens‡ 115 (46.1) 16.93 21.39 20.38 26.19 26.14 17.84 22.87 21.74 27.13 27.09 18.70 24.25 23.00 27.91 27.88 Sensĕ 38.48 35.04 32.54 32.15 32.08 39.00 35.55 33.04 33.27 33.23 39.38 35.92 33.43 34.21 34.17 Total 20.75 26.26 25.16 32.15 32.08 21.85 28.06 26.83 33.27 33.23 22.90 29.75 28.40 34.21 34.17 Sens‡ Capacity MBtuh 31.84 28.65 26.35 26.19 26.14 32.30 29.10 26.77 27.13 27.09 32.64 29.43 27.10 27.91 27.88 Total Capacity MBtuh 31.37 28.52 26.45 26.31 26.28 31.76 28.88 26.81 27.16 27.13 32.03 29.14 27.07 27.85 27.82 Total Capacity MBtuh 4.38 4.38 4.38 4.38 4.38 4.41 4.42 4.42 4.42 4.42 4.44 4.45 4.45 4.45 4.45 Total Syst. KW** 3.49 3.46 3.44 3.43 3.43 3.54 3.50 3.48 3.48 3.48 3.58 3.55 3.53 3.53 3.53 Total Syst. KW** 3.46 3.44 3.43 3.43 3.43 3.50 3.49 3.48 3.48 3.48 3.54 3.53 3.52 3.52 3.52 Total Syst. KW** 125 (51.7) 125 (51.7) 16.51 21.29 20.32 24.65 24.62 17.40 22.75 21.66 25.40 25.37 18.26 24.10 22.89 26.00 25.98 Sens‡ 125 (51.7) 16.16 20.61 19.58 24.68 24.65 17.05 22.05 20.91 25.54 25.51 17.91 23.39 22.13 26.25 26.22 Sensĕ 35.14 31.98 29.68 29.82 29.78 35.57 32.39 30.10 30.82 30.78 35.86 32.71 30.42 31.64 31.60 Total 19.57 25.05 23.95 29.82 29.78 20.66 26.81 25.58 30.82 30.78 21.70 28.46 27.09 31.64 31.60 Sens‡ Capacity MBtuh 29.62 26.64 24.46 24.68 24.65 30.01 27.02 24.83 25.54 25.51 30.29 27.31 25.12 26.25 26.22 Total Capacity MBtuh 28.97 26.33 24.41 24.65 24.62 29.28 26.62 24.71 25.40 25.37 29.50 26.85 24.93 26.00 25.98 Total Capacity MBtuh 4.98 5.00 5.01 5.01 5.01 5.02 5.03 5.04 5.04 5.04 5.05 5.06 5.08 5.07 5.07 Total Syst. KW** 3.84 3.81 3.80 3.80 3.80 3.89 3.86 3.84 3.85 3.85 3.93 3.90 3.88 3.89 3.89 Total Syst. KW** 3.85 3.84 3.84 3.84 3.84 3.90 3.89 3.88 3.88 3.88 3.94 3.93 3.92 3.93 3.93 Total Syst. KW** 15 72 (22.2) 67 (19.4) 63 (17.2)†† 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 63 (17.2)†† 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 63 (17.2)†† 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 63 (17.2)†† 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 63 (17.2)†† 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 63 (17.2)†† 62 (16.7) 57 (13.9) 75 (23.9) 28.05 34.45 33.15 40.65 44.33 29.37 36.59 35.15 43.44 46.14 30.65 38.69 37.10 45.92 47.65 Sens‡ 64.47 58.76 54.60 53.59 51.87 65.61 59.86 55.66 54.79 53.97 66.47 60.67 56.46 55.83 55.71 Total 36.36 44.97 43.31 53.34 51.87 38.13 47.88 46.01 57.14 53.97 39.80 50.65 48.58 55.83 55.71 Sens‡ Capacity MBtuh 55.75 50.68 46.99 46.10 44.33 56.80 51.68 47.95 47.16 46.14 57.65 52.48 48.72 48.09 47.65 Total Capacity MBtuh 75 (23.9) 3.53 3.50 3.48 3.48 3.47 3.59 3.57 3.55 3.55 3.54 3.66 3.63 3.61 3.61 3.61 Total Syst. KW** 3.23 3.22 3.22 3.21 3.21 3.28 3.28 3.27 3.27 3.26 3.33 3.33 3.32 3.32 3.32 Total Syst. KW** 85 (29.4) 27.12 33.53 32.23 39.69 42.76 28.42 35.66 34.21 42.39 44.46 29.68 37.72 36.13 45.99 45.88 Sens‡ 61.69 56.25 52.27 51.34 50.08 62.71 57.21 53.22 52.47 52.05 63.48 57.94 53.93 53.75 53.68 Total 35.21 43.82 42.16 52.14 50.08 36.95 46.69 44.83 55.78 52.05 38.61 49.44 47.38 53.75 53.68 Sens‡ Capacity MBtuh 53.27 48.45 44.92 44.11 42.76 54.22 49.35 45.79 45.10 44.46 54.95 50.04 46.47 45.99 45.88 Total Capacity MBtuh 85 (29.4) Total Syst. KW** 25HCE460---30, 3.88 3.86 3.84 3.84 3.83 3.95 3.92 3.91 3.90 3.90 4.02 3.99 3.97 3.97 3.97 50, 60 58.75 53.58 49.79 48.98 48.17 59.66 54.43 50.64 50.08 49.99 60.32 55.07 51.26 51.56 51.49 Total Total Capacity MBtuh Syst. Sens‡ Total Sens‡ KW** Outdoor Section With FX4DN(B,F)061L Indoor Section 34.01 4.30 55.61 32.74 42.62 4.27 50.71 41.34 40.96 4.25 47.13 39.68 50.87 4.25 46.43 49.42 48.17 4.25 46.08 46.08 35.74 4.37 56.39 34.44 45.47 4.34 51.45 44.16 43.61 4.32 47.87 42.29 50.08 4.32 47.80 47.80 49.99 4.32 47.74 47.74 37.37 4.43 56.96 36.06 48.18 4.40 51.99 46.83 46.11 4.38 48.41 44.76 51.56 4.39 49.17 49.17 51.49 4.39 49.12 49.12 Capacity MBtuh CONDENSER ENTERING AIR TEMPERATURES ° F (° C) 95 (35) 105 (40.6) Total Total Capacity MBtuh Capacity MBtuh Syst. Syst. Total Sens‡ Total Sens‡ KW** KW** 25HCE448---30, 50, 60 Outdoor Section With FB4CNP048L Indoor Section 3.59 50.55 26.11 3.96 47.46 24.99 3.57 46.00 32.52 3.93 43.23 31.42 3.55 42.67 31.23 3.91 40.12 30.14 3.55 41.94 38.63 3.91 39.54 37.40 3.54 41.05 41.05 3.90 39.07 39.07 3.64 51.35 27.39 4.01 48.15 26.25 3.62 46.77 34.62 3.99 43.87 33.48 3.61 43.42 33.18 3.96 40.77 32.06 3.60 42.90 41.17 3.96 40.54 40.54 3.60 42.61 42.61 3.96 40.49 40.49 3.69 52.00 28.64 4.06 48.67 27.48 3.67 47.37 36.65 4.04 44.38 35.48 3.66 44.02 35.07 4.02 41.28 33.91 3.66 43.96 43.96 4.02 41.71 41.71 3.66 43.91 43.91 4.02 41.66 41.66 CONDENSER ENTERING AIR TEMPERATURES ° F (° C) 95 (35) 105 (40.6) 4.78 4.76 4.74 4.73 4.73 4.85 4.82 4.80 4.80 4.80 4.91 4.89 4.87 4.87 4.87 Total Syst. KW** 4.37 4.34 4.31 4.31 4.30 4.42 4.39 4.37 4.37 4.37 4.47 4.45 4.42 4.43 4.43 Total Syst. KW** 115 (46.1) 115 (46.1) 23.75 30.17 28.91 36.87 36.80 24.98 32.20 30.79 38.10 38.06 26.19 34.15 32.58 39.13 39.09 Sens‡ 52.18 47.58 44.21 43.81 43.74 52.83 48.19 44.85 45.32 45.26 53.30 48.67 45.32 46.57 46.49 Total 31.36 39.96 38.28 43.81 43.74 33.04 42.72 40.86 45.32 45.26 34.64 45.37 43.28 46.57 46.49 Sens‡ Capacity MBtuh 44.01 40.10 37.25 36.87 36.80 44.55 40.64 37.78 38.10 38.06 44.97 41.04 38.20 39.13 39.09 Total Capacity MBtuh 5.34 5.32 5.29 5.29 5.29 5.41 5.38 5.36 5.36 5.36 5.47 5.45 5.43 5.44 5.43 Total Syst. KW** 4.83 4.80 4.78 4.77 4.77 4.88 4.85 4.83 4.83 4.83 4.93 4.91 4.88 4.89 4.89 Total Syst. KW** 125 (51.7) 125 (51.7) 22.38 28.79 27.52 34.21 34.17 23.60 30.76 29.35 35.30 35.26 24.79 32.64 31.07 36.17 36.13 Sens‡ 48.43 44.10 40.98 41.19 41.14 48.97 44.64 41.52 42.54 42.49 49.33 45.03 41.91 43.63 43.58 Total 29.90 38.44 36.76 41.19 41.14 31.55 41.17 39.29 42.54 42.49 33.13 43.74 41.63 43.63 43.58 Sens‡ Capacity MBtuh 40.13 36.59 34.00 34.21 34.17 40.56 37.01 34.43 35.30 35.26 40.86 37.34 34.78 36.17 36.13 Total Capacity MBtuh # Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per AHRI standard 210/240--- 2008. If additional tubing length and/or indoor unit is located above outdoor unit, a slight variation in capacity may occur. } Sensible capacities shown are based on 80_F (27_C) entering air at the indoor coil. For sensible capacities at other than 80_F (27_C), deduct 835 Btuh (245 kW) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80_F (27_C), or add 835 Btuh (245 kW) per 1000 CFM (480 L/S) of indoor coil air per degree above 80_F (27_C). ** Total System. kw is total of indoor and outdoor unit kilowatts. {{ At TVA rating indoor condition (75_F edb/63_F ewb). All other indoor air temperatures are at 80_F edb. NOTE: When the required data falls between the published data, interpolation may be performed. Extrapolation is not an acceptable practice. EWB — Entering Wet Bulb 2250 2000 1750 CFM EWB ° F (° C) EVAPORATOR AIR 1800 1600 1400 CFM EWB ° F (° C) EVAPORATOR AIR DETAILED COOLING CAPACITIES# CONTINUED 5.99 5.96 5.94 5.94 5.94 6.06 6.03 6.01 6.02 6.02 6.12 6.09 6.07 6.09 6.09 Total Syst. KW** 5.35 5.33 5.32 5.32 5.32 5.40 5.38 5.37 5.38 5.37 5.45 5.44 5.42 5.43 5.43 Total Syst. KW** 16 75 75 (23.9) 11.92 12.15 1350 11.66 1050 1200 12.80 1350 12.30 1050 12.56 13.43 1350 1200 13.19 12.92 1050 1200 9.95 1125 9.61 875 9.86 10.44 1125 1050 10.34 1050 10.08 10.91 1125 875 10.81 10.54 875 1050 7.55 900 7.30 700 7.44 7.96 900 800 7.84 7.69 700 800 8.35 900 8.09 700 8.23 4.84 675 800 4.74 4.65 525 600 5.16 675 4.98 525 5.08 5.44 675 600 5.36 11.18 10.97 10.73 11.77 11.56 11.32 12.35 12.13 11.89 9.16 9.07 8.84 9.60 9.51 9.27 10.04 9.95 9.70 6.95 6.84 6.71 7.32 7.21 7.08 7.69 7.57 7.45 4.45 4.36 4.28 4.75 4.67 4.58 5.01 4.93 4.84 5.26 525 600 Capacity MBtuh Total Integ* -3 (19.4) CFM See notes on page 17 70 65 65 (18.3) 70 (21.1) 75 75 (23.9) 65 70 70 (21.1) 65 (18.3) 65 65 (18.3) 75 75 75 (23.9) 75 (23.9) 70 70 (21.1) 70 65 65 (18.3) 70 (21.1) EDB ° F (° C) EDB INDOOR AIR 2.40 2.37 2.35 2.31 2.28 2.26 2.23 2.20 2.18 1.97 1.96 1.95 1.90 1.89 1.87 1.82 1.81 1.80 1.68 1.67 1.67 1.61 1.60 1.60 1.54 1.54 1.53 1.14 1.13 1.13 1.09 1.08 1.08 1.04 1.04 1.03 Total Syst. KW{ 15.87 15.60 15.30 16.48 16.22 15.91 17.08 16.81 16.50 13.05 12.94 12.64 13.51 13.40 13.10 13.99 13.87 13.55 10.03 9.90 9.74 10.43 10.29 10.12 10.81 10.66 10.51 7.05 6.95 6.83 7.38 7.27 7.15 7.66 7.57 7.45 14.58 14.34 14.06 15.15 14.90 14.62 15.69 15.44 15.16 11.99 11.89 11.62 12.42 12.31 12.04 12.85 12.75 12.45 9.22 9.10 8.95 9.59 9.45 9.30 9.93 9.80 9.65 6.48 6.39 6.27 6.78 6.68 6.57 7.04 6.95 6.84 Capacity MBtuh Total Integ* 7 (-13.9) HEAT PUMP HEATING PERFORMANCE 2.47 2.45 2.43 2.38 2.36 2.34 2.29 2.27 2.26 2.04 2.03 2.02 1.96 1.95 1.95 1.88 1.88 1.87 1.73 1.73 1.73 1.66 1.65 1.66 1.59 1.58 1.59 1.19 1.19 1.19 1.14 1.14 1.14 1.09 1.09 1.09 Total Syst. KW{ 27 (-2.i8) 37 (2.8) 19.85 19.54 19.20 20.47 20.15 19.81 21.13 20.77 20.40 16.87 16.76 16.08 17.23 17.12 16.82 17.54 17.44 17.16 12.73 12.57 12.37 13.21 12.99 12.77 13.78 13.63 13.25 9.44 9.31 9.15 9.77 9.64 9.49 10.09 9.96 9.80 1.24 1.24 1.25 1.18 1.19 1.20 1.13 1.13 1.14 12.30 12.16 11.98 12.58 12.45 12.28 12.83 12.70 12.54 10.93 10.80 10.64 11.17 11.05 10.90 11.40 11.28 11.14 1.30 1.31 1.33 1.24 1.25 1.27 1.18 1.19 1.21 14.86 14.69 14.49 15.14 14.98 14.78 15.43 15.26 15.07 13.52 13.37 13.19 13.78 13.63 13.45 14.04 13.89 13.71 1.79 1.79 1.80 1.71 1.71 1.72 1.64 1.64 1.65 15.88 15.73 15.54 16.16 15.99 15.81 16.44 16.28 16.10 14.10 13.97 13.80 14.35 14.20 14.04 14.60 14.46 14.30 1.85 1.86 1.88 1.77 1.78 1.80 1.69 1.70 1.71 18.76 18.58 18.37 19.08 18.89 18.67 19.41 19.22 18.99 17.07 16.91 16.72 17.37 17.19 16.99 17.67 17.49 17.28 2.12 2.12 2.11 2.04 2.03 2.04 1.95 1.95 1.95 20.23 20.11 19.78 20.59 20.47 20.13 20.96 20.83 20.49 17.97 17.86 17.57 18.29 18.18 17.88 18.61 18.50 18.19 2.20 2.20 2.22 2.11 2.11 2.13 2.02 2.02 2.04 24.04 23.89 23.48 24.46 24.31 23.89 24.88 24.73 24.30 21.88 21.74 21.37 22.26 22.12 21.74 22.64 22.50 22.12 18.10 17.82 17.50 18.66 18.38 18.06 19.27 18.94 18.60 2.55 2.53 2.53 2.45 2.44 2.43 2.36 2.35 2.34 24.69 24.41 24.07 25.10 24.82 24.51 25.51 25.23 24.90 21.93 21.68 21.37 22.29 22.05 21.77 22.66 22.40 22.12 2.65 2.65 2.66 2.55 2.54 2.55 2.44 2.44 2.45 28.91 28.60 28.23 29.36 29.04 28.67 29.82 29.49 29.12 26.31 26.02 25.69 26.72 26.43 26.09 27.14 26.84 26.50 25HCE436---31 Outdoor Section With FB4CNP036L Indoor Section 15.39 15.28 14.66 15.71 15.61 15.34 15.99 15.90 15.64 25HCE430---30 Outdoor Section With FB4CNP030L Indoor Section 11.61 11.46 11.28 12.05 11.84 11.64 12.56 12.43 12.08 25HCE424---30 Outdoor Section With FB4CNP030L Indoor Section 8.61 8.49 8.35 8.91 8.79 8.65 9.20 9.08 8.94 2.74 2.75 2.77 2.63 2.63 2.65 2.52 2.53 2.55 2.29 2.30 2.32 2.20 2.20 2.23 2.11 2.11 2.14 1.92 1.93 1.96 1.83 1.84 1.87 1.74 1.76 1.79 1.36 1.37 1.40 1.29 1.31 1.33 1.23 1.24 1.27 Total Syst. KW{ OUTDOOR COIL ENTERING AIR TEMPERATURES ° F (° C) Capacity Total Capacity Total Capacity MBtuh Syst. MBtuh Syst. MBtuh KW{ KW{ Total Integ* Total Integ* Total Integ* 25HCE418---30 Outdoor Section With FB4CNP018L Indoor Section 17 (-8.3) 47 (8.3) 33.66 33.28 32.83 34.19 33.80 33.35 34.70 34.32 33.86 28.30 28.11 27.62 28.79 28.60 28.09 29.28 29.10 28.57 22.08 21.86 21.60 22.42 22.20 21.95 22.78 22.55 22.27 17.67 17.46 17.21 18.01 17.80 17.54 18.33 18.13 17.87 33.66 33.28 32.83 34.19 33.80 33.35 34.70 34.32 33.86 28.30 28.11 27.62 28.79 28.60 28.09 29.28 29.10 28.57 22.08 21.86 21.60 22.42 22.20 21.95 22.78 22.55 22.27 17.67 17.46 17.21 18.01 17.80 17.54 18.33 18.13 17.87 Capacity MBtuh Total Integ* 2.84 2.85 2.89 2.72 2.74 2.77 2.61 2.63 2.66 2.40 2.41 2.45 2.31 2.31 2.35 2.22 2.22 2.26 2.00 2.02 2.06 1.91 1.93 1.96 1.82 1.84 1.88 1.42 1.45 1.48 1.36 1.38 1.41 1.29 1.31 1.35 Total Syst. KW{ 57 (13.9) 39.03 38.54 37.95 39.70 39.20 38.60 40.38 39.87 39.25 33.08 32.93 32.34 33.53 33.42 32.88 33.88 33.84 33.42 25.68 25.53 25.21 25.96 25.88 25.62 26.20 26.19 26.02 20.82 20.55 20.22 21.21 20.95 20.61 21.54 21.35 21.00 39.03 38.54 37.95 39.70 39.20 38.60 40.38 39.87 39.25 33.08 32.93 32.34 33.53 33.42 32.88 33.88 33.84 33.42 25.68 25.53 25.21 25.96 25.88 25.62 26.20 26.19 26.02 20.82 20.55 20.22 21.21 20.95 20.61 21.54 21.35 21.00 Capacity MBtuh Total Integ* 2.98 3.00 3.06 2.85 2.88 2.93 2.74 2.76 2.81 2.52 2.54 2.60 2.42 2.44 2.50 2.32 2.34 2.40 2.08 2.12 2.18 1.98 2.02 2.08 1.89 1.92 1.98 1.51 1.54 1.58 1.44 1.47 1.51 1.37 1.40 1.44 Total Syst. KW{ 67 (19.4) 45.28 44.68 43.92 46.01 45.47 44.71 46.70 46.23 45.49 37.07 37.11 37.01 0.00 37.51 37.48 37.80 37.90 37.91 28.88 28.93 28.90 29.10 29.23 29.23 29.26 29.49 29.55 23.75 23.68 23.47 24.05 24.01 23.84 24.32 24.32 24.19 45.28 44.68 43.92 46.01 45.47 44.71 46.70 46.23 45.49 37.07 37.11 37.01 0.00 37.51 37.48 37.80 37.90 37.91 28.88 28.93 28.90 29.10 29.23 29.23 29.26 29.49 29.55 23.75 23.68 23.47 24.05 24.01 23.84 24.32 24.32 24.19 Capacity MBtuh Total Integ* 3.16 3.22 3.29 3.02 3.07 3.15 2.88 2.94 3.02 2.62 2.64 2.73 0.00 2.53 2.62 2.41 2.43 2.51 2.15 2.20 2.26 2.05 2.10 2.16 1.95 2.00 2.06 1.58 1.62 1.69 1.50 1.55 1.61 1.43 1.47 1.53 Total Syst. KW{ 17 20.74 21.08 19.58 19.94 20.28 2000 2250 1750 2000 2250 17.00 1800 20.38 16.69 1600 1750 16.35 1400 21.84 14.51 1575 2250 14.27 1400 21.51 14.00 1225 21.14 15.33 1575 2000 15.07 1400 1750 14.78 1225 13.58 16.19 1575 1800 15.91 1400 13.37 15.59 1225 1600 10.17 1350 13.11 9.95 1200 1400 9.70 1050 16.05 10.93 1350 1800 10.70 1200 15.80 10.46 1050 1600 11.64 1350 15.48 11.41 1200 1400 11.16 Total 18.65 18.35 18.01 19.40 19.08 18.75 20.10 19.79 19.45 12.49 12.30 12.07 14.76 14.54 14.25 15.64 15.36 15.04 13.34 13.13 12.88 14.10 13.87 13.60 14.89 14.64 14.35 9.36 9.15 8.93 10.06 9.85 9.62 10.71 10.50 10.27 Integ* Capacity MBtuh 1050 CFM ---3 ( ---19.4) 3.71 3.67 3.63 3.55 3.51 3.48 3.40 3.36 3.33 3.25 3.22 3.19 2.91 2.87 2.85 2.81 2.78 2.75 2.71 2.69 2.68 2.61 2.59 2.58 2.51 2.50 2.48 2.21 2.18 2.15 2.13 2.10 2.07 2.05 2.02 2.00 Total Syst. KW{ 26.15 25.78 25.36 26.91 26.54 26.13 27.62 27.26 26.85 18.88 18.63 18.31 21.28 20.97 20.60 22.12 21.78 21.40 19.07 18.80 18.50 19.82 19.52 19.20 20.58 20.28 19.93 14.23 13.95 13.67 14.95 14.69 14.39 15.65 15.38 15.07 Total 24.03 23.69 23.30 24.73 24.39 24.01 25.39 25.05 24.67 17.35 17.12 16.83 19.55 19.27 18.93 20.33 20.01 19.66 17.53 17.28 17.00 18.21 17.94 17.64 18.91 18.64 18.31 13.07 12.81 12.56 13.74 13.50 13.22 14.38 14.13 13.85 Integ* Capacity MBtuh 7 ( ---13.9) 3.83 3.80 3.78 3.67 3.64 3.62 3.51 3.48 3.46 3.38 3.35 3.34 3.02 2.99 2.97 2.91 2.89 2.87 2.81 2.80 2.79 2.71 2.69 2.69 2.60 2.59 2.59 2.33 2.31 2.29 2.25 2.22 2.20 2.16 2.14 2.12 Total Syst. KW{ 32.52 32.10 31.62 33.30 32.87 32.40 34.07 33.65 33.16 24.50 24.21 23.83 26.84 26.47 26.05 27.64 27.25 26.82 24.05 23.74 23.38 24.79 24.44 24.06 26.05 25.75 24.83 18.43 18.12 17.76 19.14 18.83 18.47 19.81 19.51 19.14 Total Total Syst. KW{ Total Integ* Capacity MBtuh 27 ( ---2.8) Total Syst. KW{ Total Integ* Capacity MBtuh 37 (2.8) 23.03 22.61 22.17 24.15 23.84 23.05 24.67 24.36 24.01 20.46 20.08 19.69 21.45 21.17 20.47 21.91 21.64 21.33 2.54 2.53 2.53 2.46 2.45 2.44 2.36 2.35 2.36 28.00 27.66 27.29 28.50 28.16 27.78 29.02 28.69 28.28 25.48 25.17 24.83 25.94 25.63 25.28 26.41 26.11 25.73 2.93 2.92 2.93 2.82 2.81 2.82 2.72 2.72 2.71 29.95 29.68 29.35 30.42 30.13 29.80 30.91 30.60 30.26 26.60 26.36 26.07 27.02 26.76 26.47 27.46 27.17 26.88 3.07 3.09 3.11 2.95 2.96 2.98 2.84 2.84 2.87 35.39 35.07 34.70 35.89 35.55 35.19 36.39 36.05 35.66 32.20 31.92 31.57 32.66 32.35 32.02 33.12 32.81 32.45 25HCE442---30 Outdoor Section With FB4CNP042L Indoor Section 2.44 2.42 2.41 2.34 2.33 2.32 2.25 2.24 2.23 3.21 3.24 3.28 3.09 3.10 3.14 2.96 2.98 3.01 2.65 2.66 2.68 2.54 2.54 2.56 2.43 2.44 2.45 3.51 3.50 3.50 3.13 3.12 3.11 3.02 3.00 3.00 30.57 30.22 29.75 33.71 33.35 32.86 34.22 33.88 33.50 27.15 26.84 26.42 29.94 29.62 29.19 30.40 30.09 29.76 3.66 3.66 3.67 3.29 3.28 3.29 3.17 3.16 3.17 37.88 37.55 37.16 39.47 39.10 38.68 40.06 39.67 39.20 34.48 34.17 33.82 35.92 35.58 35.20 36.45 36.10 35.67 3.87 3.89 3.93 3.42 3.42 3.45 3.28 3.29 3.31 29.65 29.27 28.83 30.36 29.97 29.54 31.07 30.68 30.23 3.96 3.94 3.94 3.79 3.77 3.76 3.63 3.61 3.60 40.49 40.12 39.67 40.95 40.59 40.19 41.40 41.05 40.66 35.96 35.64 35.23 36.37 36.05 35.69 36.77 36.45 36.11 4.14 4.14 4.16 3.96 3.96 3.97 3.78 3.77 3.79 47.28 46.85 46.37 47.88 47.44 46.94 48.48 48.03 47.51 43.02 42.63 42.20 43.57 43.17 42.71 44.12 43.70 43.23 4.28 4.29 4.33 4.09 4.11 4.14 3.91 3.92 3.95 25HCE460---30, 50, 60 Outdoor Section With FX4DN(B,F)061L Indoor Section 22.34 22.07 21.72 24.47 24.14 23.75 25.20 24.85 24.46 25HCE448---30, 50, 60 Outdoor Section With FB4CNP048L Indoor Section 21.93 21.65 21.32 22.60 22.28 21.93 23.75 23.48 22.64 16.80 16.52 16.19 17.45 17.16 16.84 18.06 17.79 17.46 Total Syst. KW{ CONDENSER ENTERING AIR TEMPERATURES ° F (° C) 25HCE436---51, 61 Outdoor Section With FB4CNP036L Indoor Section Integ* Capacity MBtuh 17 ( ---8.3) 47 (8.3) 54.97 54.42 53.80 55.71 55.15 54.50 56.46 55.88 55.22 43.96 43.52 43.00 46.04 45.56 45.00 46.75 46.26 45.68 41.30 40.89 40.41 41.91 41.49 41.00 42.45 42.10 41.58 32.84 32.46 32.01 33.40 33.00 32.54 33.96 33.56 33.08 Total 54.97 54.42 53.80 55.71 55.15 54.50 56.46 55.88 55.22 43.96 43.52 43.00 46.04 45.56 45.00 46.75 46.26 45.68 41.30 40.89 40.41 41.91 41.49 41.00 42.45 42.10 41.58 32.84 32.46 32.01 33.40 33.00 32.54 33.96 33.56 33.08 Integ* Capacity MBtuh 4.43 4.46 4.52 4.25 4.27 4.32 4.07 4.08 4.13 4.04 4.07 4.12 3.56 3.58 3.62 3.42 3.44 3.48 3.38 3.41 3.47 3.24 3.27 3.32 3.10 3.14 3.18 2.76 2.77 2.81 2.64 2.66 2.69 2.53 2.55 2.57 Total Syst. KW{ 57 (13.9) 63.78 63.33 62.59 64.55 64.14 63.44 65.31 64.95 64.29 51.35 50.66 49.89 53.98 53.28 52.51 54.77 54.19 53.36 47.26 47.13 46.83 47.75 47.70 47.42 48.18 48.21 48.02 38.44 37.98 37.41 39.11 38.62 38.04 39.79 39.29 38.68 Total 63.78 63.33 62.59 64.55 64.14 63.44 65.31 64.95 64.29 51.35 50.66 49.89 53.98 53.28 52.51 54.77 54.19 53.36 47.26 47.13 46.83 47.75 47.70 47.42 48.18 48.21 48.02 38.44 37.98 37.41 39.11 38.62 38.04 39.79 39.29 38.68 Integ* Capacity MBtuh 4.57 4.63 4.72 4.38 4.42 4.51 4.19 4.23 4.32 4.20 4.25 4.32 3.72 3.75 3.82 3.57 3.61 3.67 3.50 3.55 3.64 3.35 3.40 3.48 3.20 3.26 3.34 2.90 2.93 2.97 2.79 2.81 2.85 2.67 2.70 2.74 Total Syst. KW{ 67 (19.4) 71.82 71.81 71.50 72.63 72.69 72.41 73.39 73.54 73.31 59.33 58.86 58.18 61.98 61.59 61.02 62.78 62.42 61.87 52.23 52.43 52.47 52.74 52.99 53.09 53.24 53.51 53.69 45.38 44.77 44.31 46.16 45.55 44.81 46.95 46.33 45.56 Total 71.82 71.81 71.50 72.63 72.69 72.41 73.39 73.54 73.31 59.33 58.86 58.18 61.98 61.59 61.02 62.78 62.42 61.87 52.23 52.43 52.47 52.74 52.99 53.09 53.24 53.51 53.69 45.38 44.77 44.31 46.16 45.55 44.81 46.95 46.33 45.56 Integ* Capacity MBtuh NOTE: When the required data falls between the published data, interpolation may be performed. Extrapolation is not an acceptable practice. * The Btuh heating capacity values shown are net integrated values from which the defrost effect has been subtracted. The Btuh heating from supplement heaters should be added to those values to obtain total Sys. capacity. { The kW values include the compressor, outdoor fan motor, and indoor blower motor. The kW from supplement heaters should be added to these values to obtain total Sys. kilowatts. EDB — Entering Dry Bulb 75 (23.9) 70 (21.1) 65 (18.3) 75 (23.9) 70 (21.1) 65 (18.3) 75 (23.9) 70 (21.1) 65 (18.3) 75 (23.9) 70 (21.1) 65 (18.3) EDB INDOOR AIR HEAT PUMP HEATING PERFORMANCE CONTINUED 4.73 4.80 4.92 4.53 4.60 4.70 4.34 4.40 4.50 4.37 4.43 4.52 3.87 3.92 4.00 3.72 3.76 3.84 3.60 3.68 3.79 3.45 3.52 3.62 3.31 3.37 3.47 3.12 3.15 3.19 3.00 3.03 3.09 2.89 2.92 2.97 Total Syst. KW{ GUIDE SPECIFICATIONS GENERAL System Description AIR--COOLED, SPLIT--SYSTEM HEAT PUMP 25HCE4 1--1/2 TO 5 NOMINAL TONS Fans Outdoor--mounted, air--cooled, split--system heat pump unit suitable for ground or rooftop installation. Unit consists of a hermetic compressor, an air--cooled coil, propeller--type condenser fan, and a control box. Unit will discharge supply air upward as shown on contract drawings. Unit will be used in a refrigeration circuit to match up to a packaged fan coil or coil unit. — — — — — Quality Assurance — — — — — — — Unit will be rated in accordance with the latest edition of AHRI Standard 240. Unit will be certified for capacity and efficiency, and listed in the latest AHRI directory. Unit construction will comply with latest edition of ANSI/ ASHRAE and with NEC. Unit will be constructed in accordance with UL standards and will carry the UL label of approval. Unit will have C--UL approval. Unit cabinet will be capable of withstanding Federal Test Method Standard No. 141 (Method 6061) 500--hr salt spray test. Air--cooled condenser coils are pressure tested and the outdoor unit is leak tested. Unit constructed in ISO9001 approved facility. Compressor — — Unit will be shipped as single package only and is stored and handled per unit manufacturer’s recommendations. Warranty (for inclusion by specifying engineer) — — — — — U.S. and Canada only. — Factory assembled, single piece, air--cooled heat pump unit. Contained within the unit enclosure is all factory wiring, piping, controls, compressor, refrigerant charge Puronr (R--410A), and special features required prior to field start--up. — Unit Cabinet — Unit cabinet will be constructed of galvanized steel, bonderized, and coated with a powder coat paint. Available with dense grille only. Refrigeration circuit components will include liquid--line shutoff valve with sweat connections, vapor--line shutoff valve with sweat connections, system charge of Puronr (R--410A) refrigerant, POE compressor oil, accumulator, and reversing valve. Operating Characteristics Equipment — Condenser coil will be air cooled. Coil will be constructed of aluminum fins mechanically bonded to copper tubes which are then cleaned, dehydrated, and sealed. Refrigeration Components PRODUCTS — Compressor will be hermetically sealed. Compressor will be mounted on rubber vibration isolators. Condenser Coil Delivery, Storage, and Handling — Condenser fan will be direct--drive propeller type, discharging air upward. Condenser fan motors will be totally enclosed, 1--phase type with class B insulation and permanently lubricated bearings. Shafts will be corrosion resistant. Fan blades will be statically and dynamically balanced. Condenser fan openings will be equipped with steel wire safety guards. The capacity of the unit will meet or exceed _____ Btuh at a suction temperature of _____ _F/_C. The power consumption at full load will not exceed _____ kW. Combination of the unit and the evaporator or fan coil unit will have a total net cooling capacity of _____ Btuh or greater at conditions of _____ CFM entering air temperature at the evaporator at _____ _F wet bulb and _____ _F/_C dry bulb, and air entering the unit at _____ _F/_C. The system will have a SEER of _____ Btuh/watt or greater at DOE conditions. Electrical Requirements — — — Nominal unit electrical characteristics will be _____ v, single phase, 60 hz. The unit will be capable of satisfactory operation within voltage limits of _____ v to _____ v. Unit electrical power will be single point connection. Control circuit will be 24v. Special Features — 18 Refer to section of this literature identifying accessories and descriptions for specific features and available enhancements. SYSTEM DESIGN SUMMARY 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01--in. wc. Minimum outdoor operating air temperature without low--ambient operation accessory is 55_F (12.8_C). Maximum outdoor operating air temperature for cooling mode is 125_F (51.7_C). Minimum outdoor operating air temperature for heating mode is –10_F (–23.3_C). Maximum outdoor operating air temperature for heating mode is 66_F (18.9_C). For reliable operation, unit should be level in all horizontal planes. For interconnecting refrigerant tube lengths greater than 80 ft (23.4 m) and/or elevation differences between indoor and outdoor units greater than 20 ft (6.1 m), consult Residential Piping and Longline Guideline and Service Manual available from equipment distributor. If any refrigerant tubing is buried, provide a 6 in. (152.4 mm) vertical rise to the valve connections at the unit. Refrigerant tubing lengths up to 36 in. (914.4 mm) may be buried without further consideration. Do not bury refrigerant lines longer than 36 in. (914.4 mm). Use only copper wire for electric connection at unit. Aluminum and clad aluminum are not acceptable for the type of connector provided. Do not apply capillary tube indoor coils to these units. Factory--supplied filter drier must be installed. 19 Copyright 2017 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231 Edition Date: 05/17 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 20 Catalog No:25HCE4---06PD Replaces: 25HCE4--- 05PD