User guide, SDW-541-F1G-T4G and SDW-550-T5G

6644-2240
SDW-500
S
E
R
I
E
S
SDW-541-F1G-T4G
SDW-550-T5G
Industrial Ethernet
5-port Switch
www.westermo.com
© Westermo Teleindustri AB
User Guide
Legal information
The contents of this document are provided “as is”. Except as required by applicable
law, no warranties of any kind, either express or implied, including, but not limited to,
the implied warranties of merchantability and fitness for a particular purpose, are made
in relation to the accuracy and reliability or contents of this document. Westermo
reserves the right to revise this document or withdraw it at any time without prior
notice.
Under no circumstances shall Westermo be responsible for any loss of data or income
or any special, incidental, and consequential or indirect damages howsoever caused.
More information about Westermo can be found at the following Internet address:
http://www.westermo.com
2
6644-2240
Safety
!
Before installation:
Read this manual completely and gather all information on the unit. Make sure
that you understand it fully. Check that your application does not exceed the safe
operating specifications for this unit.
This unit should only be installed by qualified personnel.
This unit should be built-in to an apparatus cabinet, or similar, where access is
restricted to service personnel only.
The power supply wiring must be sufficiently fused, and if necessary it must be
possible to disconnect manually from the power supply. Ensure compliance
to national installation regulations.
This unit uses convection cooling.To avoid obstructing the air flow around the
unit, follow the spacing recommendations (see Installation section).
!
Before mounting, using or removing this unit:
Prevent access to hazardous voltage by disconnecting the unit from power supply.
Warning! Do not open connected unit. Hazardous voltage may occur within this
unit when connected to power supply.
!
Class 1 Laser Product
Do not look directly into fibre optical fibre port or any connected fibre although
this unit is designed to meet the Class 1 Laser regulations.
Care recommendations
Follow the care recommendations below to maintain full operation of unit and to fulfil
the warranty obligations.
This unit must not be operating with removed covers or lids.
Do not attempt to disassemble the unit. There are no user serviceable parts inside.
Do not drop, knock or shake the unit, rough handling above the specification may cause
damage to internal circuit boards.
Do not use harsh chemicals, cleaning solvents or strong detergents to clean the unit.
Do not paint the unit. Paint can clog the unit and prevent proper operation.
Do not expose the unit to any kind of liquids (rain, beverages, etc). The unit is not
waterproof. Keep the unit within the specified humidity levels.
Do not use or store the unit in dusty, dirty areas, connectors as well as other mechanical
part may be damaged.
If the unit is not working properly, contact the place of purchase, nearest Westermo
distributor office or Westermo Tech support.
Fibre connectors are supplied with plugs to avoid contamination inside the optical port.
As long as no optical fibre is mounted on the connector, e.g. for storage, service or
transportation, should the plug be applied.
6644-2240
3
SPECIAL CONDITION FOR SAFE USE
Ambient temperature:
This unit is designed for use in extreme ambient temperature conditions according to
the following: –40 ºC to +74 ºC (–40 ºF to +165 ºF)
Note. Fibre Optic Handling
Fibre optic equipment needs special treatment. It is very sensitive to dust and dirt. If
the fibre will be disconnected from the modem the protective hood on the transmitter/
receiver must be connected. The protective hood must be kept on during transportation.
The fibre optic cable must also be handle the same way.
If this recommendation is not, it jeopardises the warranty.
Cleaning of the optical connectors
In the event of contamination, the optical connectors should be cleaned by the use of
forced nitrogen and some kind of cleaning stick.
Recommended cleaning fluids:
• Methyl-, ethyl-, isopropyl- or isobutyl-alcohol
• Hexane
• Naphtha
Maintenance
No maintenance is required, as long as the unit is used as intended within the specified
conditions.
4
6644-2240
Agency approvals and standards compliance
Type
Approval / Compliance
EMC
Safety
EN 50121-4, Railway applications – Electromagnetic compatibility – Emission
and immunity of the signalling and telecommunications apparatus
EN 61000-6-1, Immunity residential environments
EN 61000-6-2, Immunity industrial environments
EN 61000-6-4, Emission industrial environments
EN/IEC/UL 60950-1, IT-equipment
Marine
DNV GL rules for classification – Ships and offshore units
Environmental
NEMA TS 2-2003
DNV GL rules for classification
Type
SDW-541-F1G-T4G
SDW-550-T5G
Corrosive
environment
Notice:
6644-2240
Temperature Humidity Vibration
D
B
B
EMC
Enclosure
B
A/IP21
This product has been successfully tested in a corrosion test according to
IEC 60068-2-60, method 3. This means that the product meets the requirements
to be placed in an environment classified as ISA-S71.04 class G3 and G4.
Note! If the product is placed in a corrosive environment, it is important that all
unused connector sockets are protected with a suitable plug in order to avoid
corrosion attacks on the gold plated pins in connectors.
5
Declaration of Conformity
Westermo Teleindustri AB
Declaration of Conformity
The manufacturer
Westermo Teleindustri AB
SE-640 40 Stora Sundby, Sweden
Herewith declares that the product(s)
Type of product
Industrial Ethernet switch
Model
SDW-550-T5G
SDW-541-F1G-T4G
Art no
3644-2001
3644-2020
is in conformity with the following EU directive(s).
No
2014/30/EU
Short name
Electromagnetic Compatibility (EMC)
2014/35/EU
Low Voltage Directive (LVD)
2011/65/EU
Restriction of the use of certain hazardous substances in electrical and electronic
equipment (RoHS)
References of standards applied for this EU declaration of conformity.
No
EN 61000-6-1
EN 61000-6-2
EN 61000-6-4
EN 50121-4
EN 60950-1
EN 50581
Title
Electromagnetic compatibility – Immunity for residential
environments
Electromagnetic compatibility – Immunity for industrial
environments
Electromagnetic compatibility – Emission for industrial
environments
Railway applications – Electromagnetic compatibility – Emission
and immunity of the signalling and telecommunications apparatus
Information technology equipment -- Safety -- General
requirements
Technical documentation for the assessment of electrical and
electronic products with respect to the restriction of hazardous
substances
The last two digits of the year in which the CE marking was affixed:
Issue
2007
2005
2007
2015
2006
+A11:2009
+A1: 2010
+A12:2011
+A2: 2013
2012
16
Pierre Öberg
Technical Manager
19th May 2016
6
Postadress/Postal address
Tel.
Telefax
Postgiro
Bankgiro
Org.nr/
Corp. identity number
Registered office
S-640 40 Stora Sundby
Sweden
016-428000
Int+46 16428000
016-428001
Int+46 16428001
52 72 79-4
5671-5550
556361-2604
Eskilstuna
6644-2240
Type tests and environmental conditions
Environmental phenomena Basic standard Description
ESD
EN 61000-4-2
Enclosure
Fast transients
EN 61000-4-4
Surge
EN 61000-4-5
Power port
Signal ports
Power port
Signal ports
Power frequency magnetic field EN 61000-4-8
Pulsed magnetic field
EN 61000-4-9
Radiated RF immunity
EN 61000-4-3
Enclosure
Enclosure
Enclosure
Conducted RF immunity
EN 61000-4-6
Radiated RF emission
Conducted RF emission
CISPR 16-2-3
ANSI C63,4
(FCC Part 15)
CISPR 16-2-1
Power port
Signal ports
Enclosure
Dielectric strength
EN 60950-1
Environmental
Temperatures
Relative humidity
Altitude
Service life
Reliability prediction (MTBF)
EN 60068-2-1
EN 60068-2-2
EN 60068-2-30
MIL-HDBK-217F
Test levels
Contact: ±6 kV
Air: ±8 kV
±2 kV
±2 kV
Line to earth: ±2 kV
Line to line: ±1 kV
Line to earth: ±2 kV
Line to line: ±1 kV
300 A/m; 0, 16.7, 50 Hz
300 A/m
20 V/m @ (80 – 2700) MHz
10 V/m @ (2700 – 6000) MHz
1 kHz sine, 80% AM
10 V, 80% AM, 1 kHz; (0.15 – 80) MHz
10 V, 80% AM, 1 kHz; (0.15 – 80) MHz
Class B (30 – 6000 MHz)
Class B (30 – 6500 MHz)
Power port
Signal ports
Power interface to all other
TX signal interface to all other
TX shield interface to all other
Class B
Class B
1.5kV AC @ 60s duration
1.5kV AC @ 60s duration
1.5kV AC @ 60s duration
Operating
Storage and transport
Operating
Storage and transport
–40 to +74 °C (–40 to +165 °F)
–50 to +85 °C (–58 to +185 °F)
5 to 95 % (non-condensing)
5 to 95 % (condensation allowed
outside packaging)
2 000 m/70 kPa
10 year
SDW-541-F1G-T4G: 1.182.000 hours
SDW-550-T5G: 1.121.000 hours
5–9 Hz ±6 mm
9–500 Hz ±2 g
15 g, 11 ms
Operating
Operating
Operating
Vibration
IEC 60068-2-6
(sine)
Operating
Shock
Mechanical
Enclosure
Dimension W x H x D
Weight
Mounting
Degree of protection
Cooling
IEC 60068-2-27
Operating
UL94
Plastic
EN 60529
DIN-rail
Enclosure
Flammability Class V-0
34 x 123 x 121 mm
0.2 kg
IP21
Convection
Configuration
Auto configured (auto-negotiation) or manually setting of speed and duplex of individual TX port, by DIP-switches. Port
mirror function is possible to set with DIP-switch. With the port mirror function active the switch will copy all outgoing
traffic to port 1. This can be used to monitor all traffic going out from the switch. Packets may be discarded if the total
throughput exceeds the port speed of port 1.
6644-2240
7
Description
The SDW-541-F1G-T4G is an unmanaged 5-port switch with one SFP fibre port
supporting 100 Mbit/s or Gbit Ethernet, and four copper ports supporting 10/100 Mbit/s
or Gbit Ethernet. The Westermo range of 100 Mbit or Gbit Small Form-factor Pluggable
(SFP) transceivers are available as multimode, singlemode or Bi-Di transceivers with
distance up to 120 km.
The SDW-550-T5G is an unmanaged 5-port
switch with five copper ports, all supporting 10
Mbit/s, 100 Mbit/s or Gbit Ethernet. Both are
designed for easy use in heavy duty industrial,
maritime and rail trackside applications. The
units support 802.1Q long packets which allow
all standard industrial Ethernet protocols to
be used.
The units are designed for use in industrial
applications with dual 9.6 to 57.6 VDC power
input. The unique “tri-galvanic” isolation
provides isolation between all ports, power
supply and between each chassis screen
avoiding ground loop currents. The IP21
rating ensures that the unit can be installed in
locations where condensed water may occur.
Only industrial grade components are used
which gives an MTBF of 1.182.000 hours for
the SDW-541-F1T4G and 1.121.000 hours for
the SDW-550-T5G and thus ensures a long
service life. A wide operating temperature
range of –40 to +74 °C (–40 to +165 °F) can
be achieved with no moving parts.
The units have been tested both by Westermo and external test houses to meet EMC,
isolation, vibration and shock standards, all to the highest levels suitable for heavy
industrial, trackside and maritime environments.
Network diagnostics are simplified with the inclusion of port mirroring on one port
allowing data flow through the switch to be monitored using a network analyzer. All
five ports can have data rate and flow control locked by DIP switch which can eliminate
problems with old legacy Ethernet equipment that is unable to support auto negotiation.
8
6644-2240
Interface specifications
Power
Operating voltage
Rated current
Rated frequency
Inrush current, I2t
Startup current*
Polarity
Redundant power input
Isolation to
Connection
Connector size
Shielded cable
Rated: 12 to 48 VDC
Operating: 9.6 to 57.6 VDC
SDW-541-F1G-T4G: 12-48 VDC; 260–65mA
SDW-550-T5G: 12-48 VDC; 260–65mA
DC
22.7·10-3 A2s @ 48 VDC
2 x Rated current
Reverse polarity protected
Yes
All other
Detachable screw terminal
0.2 – 2.5 mm2 (AWG 24 – 12)
Not required
* External supply current capability for proper start-up
Ethernet TX
Electrical specification
Data rate
Duplex
Circuit type
Transmission range
Isolation to
Connection
Shielded cable
Conductive housing
Number of ports
IEEE std 802.3. 2005 Edition
10 Mbit/s, 100 Mbit/s, 1000 Mbit/s manual or auto
Full or half, manual or auto
TNV-1
Up to 150 m with CAT5e cable or better*
All other
RJ-45, auto MDI/MDI-X
Not required, except when installed in Railway applications as
signalling and telecommunications apparatus and located close
to rails.**
Yes
SDW-541-F1G-T4G: 4
SDW-550-T5G: 5
* Refer to Safety section.
** To minimise the risk of interference, a shielded cable is recommended when the cable is located inside 3 m
boundary or the cable is longer than 30 m and inside 10 m boundary to the rails and connected to this port.
Ethernet SFP pluggable connections (FX or TX) (SDW-541-F1G-T4G)
Electrical specification
IEEE std 802.3. 2005 Edition
Data rate
100 Mbit/s or 1000 Mbit/s transceivers supported
Duplex
Full or Auto, depending on transceiver
Transmission range
Depending on tranceiver
Connection
SFP slot holding fibre transceiver or copper transceiver
Number of ports
SDW-541-F1G-T4G: 1
6644-2240
9
Connections
LED indicators
Network
RJ-45 connection
Network
fibre connection
+
+
SDW-541-F1G-T4G
Power connection
SDW-550-T5G
Available models:
… SDW-541-F1G-T4G 10/100/1000Base-T/TX: 4 ports, 100/1000Base-FX: 1 port
… SDW-550-T5G 10/100/1000Base-T/TX: 5 ports
10
6644-2240
Power
The SDW-500 series supports redundant power connection. The positive
inputs are +DC1 and +DC2, the negative inputs for both supplies are
COM. The power is drawn from the input with the highest voltage.
3
4
Power
0V
9.6–57.6 VDC
9.6–57.6 VDC
0V
2
Description
COM
+DC1
+DC2
COM
1
4-pos screw terminal
1
2
3
4
TX
Ethernet TX connection (RJ-45 connector), automatic MDI/MDI-X crossover.
Contact Direction Description/Remark
1
In/Out
BI_DA+
2
In/Out
BI_DA3
In/Out
BI_DB+
4
In/Out
BI_DC+
5
In/Out
BI_DC6
In/Out
BI_DB7
In/Out
BI_DD+
8
In/Out
BI_DDShield
In/Out
Connected to PE
8
7
6
5
4
3
2
1
CAT 5 cable is recommended.
Unshielded (UTP) or shielded (STP) connector might be used.
F1G, 1 SFP slot
The F1G interface has one SFP slot supporting Ethernet 100/1000
BaseFX/X. Each slot can hold one SFP transceiver for copper or fibre
cable. For supported transceivers see SFP transceivers user guide (art
no. 6100-0000) available at www.westermo. com.
6644-2240
11
DIP switch settings SDW-541-F1G-T4G and SDW-550-T5G
DIP-switches are accessible under the lid on top of the unit. DIP-switches are used to
configure the unit.
!
Warning!
Prevent damage to internal electronics from electrostatic discharges (ESD) by
discharging your body to a grounding point (e.g. use of wrist strap), before the lid
on top/front of the unit is removed.
!
Warning! Do not open connected equipment.
Prevent access to hazardous voltages by disconnecting the unit from AC/DC mains
supply and all other electrical connections.
NOTE
When configuration via DIP-switches, the settings of DIP-switches configure the unit only
after a reboot (power off/on).
Observe this when the DIP-switches are configured
… Speed and duplex setting only valid when auto-negotiation is disabled.
… When monitoring selected all outgoing packets from the switch is also copied to the
port 1.
… Speed and duplex switch settings are ignored for FX ports.
… If auto-negotiation and auto MDI/MDI-X disabled all TX ports support MDI-X
configuration.
… If Hub mode is selected, all incoming and outgoing packets are distributed on all other
ports.
ONLY VALID FOR SDW-541-F1G-T4G
… Speed and duplex switch settings are ignored for FX ports.
… If auto-negotiation and auto MDI/MDI-X disabled all TX ports support MDI-X
configuration.
12
6644-2240
Port settings
Port 2 settings
Port 1 settings
ON
S1
1 2 34 56 78 9 10
ON
S1
Auto-negotiation enabled
10/100/1000 Mbit/s speed
selected
100 Mbit/s speed selected
ON
S1
1 2 34 56 78 9 10
ON
S1
1 2 34 56 78 9 10
1 2 34 56 78 9 10
10 Mbit/s speed selected
ON
S1
1 2 34 56 78 9 10
Full duplex selected
ON
1 2 34 56 78 9 10
Half duplex selected
S1
1 2 34 56 78 9 10
Port 3 settings
S1
1 2 34 56 78 9 10
ON
S1
Auto-negotiation enabled
10/100/1000 Mbit/s speed
selected
100 Mbit/s speed selected
10 Mbit/s speed selected
ON
Full duplex selected
ON
S1
1 2 34 56 78 9 10
ON
ON
S1
ON
ON
Port 5 settings below only valid for
SDW-550-T5G
Port 5 settings
1000 Mbit/s speed selected
Port 5 settings
ON
S2
1 2 34 56 78 9 10
1 2 34 56 78 9 10
S2
ON
100 Mbit/s speed selected
ON
S2
1 2 34 56 78 9 10
S2
ON
1 2 34 56 78 9 10
Auto-negotiation enabled
10/100/1000 Mbit/s speed
selected
100 Mbit/s speed selected
S2
1 2 34 56 78 9 10
1 2 34 56 78 9 10
ON
Half duplex selected
ON
S2
1 2 34 56 78 9 10
Port 5 settings below only valid for
SDW-541-F1G-T4G
ON
Full duplex selected
ON
1 2 34 56 78 9 10
S2
10 Mbit/s speed
selected
1 2 34 56 78 9 10
Half duplex selected
ON
S2
1 2 34 5
S2
1 2 34 56 78 9 10
S1
Auto-negotiation enabled
10/100/1000 Mbit/s speed
selected
100 Mbit/s speed
S2 selected
1 2 34 56 78 9 10
S1
1 2 34 56 78 9 10
1 2 34 56 78 9 10
S1
Port 4 settings
ON
1 2 34 56 78 9 10
1 2 34 56 78 9 10
S1
Half duplex selected
ON
S1
1 2 34 56 78 9 10
ON
Full duplex selected
ON
S1
1 2 34 56 78 9 10
ON
10 Mbit/s speed selected
ON
S1
1 2 34 56 78 9 10
S1
Auto-negotiation enabled
10/100/1000 Mbit/s speed
selected
100 Mbit/s speed selected
Full duplex selected.
Note: Only valid for TX
SFP
Half duplex selected.
Note: Only valid for TX
SFP
ON
10 Mbit/s speed selected
S2
1 2 34 56 78 9 10
ON
Full duplex selected
S2
1 2 34 56 78 9 10
ON
Half duplex selected
S2
1 2 34 56 78 9 10
6644-2240
13
Port mirroring settings
Factory settings
S1
ON
S2
1 2 34 56 78 9 10
S2
ON
ON
No monitoring
selected
1 2 34 56 78 9 10
1 2 34 56 78 9 10
S2
ON
Monitoring selected
1 2 34 56 78 9 10
Hub mode
S2
ON
Flow control selected
Hub mode enabled
ON
S2
1 2 34 56 78 9 10
S2
ON
Hub mode disabled
S2
1 2 34 56 78 9 10
ON
No flow control
selected
1 2 34 56 78 9 10
S1
14
Flow control selected
1 2 34 56 78 9 10
S2
6644-2240
LED indicators
Indicators (LED)
Power (PWR)
Link (LINK) of every port
Speed (SPD) and duplex (DPX) of TX ports
LED
Status
Description
PWR
ON
Slow flash
Fast flash
OFF
ON
Flash
Flash 3 Hz
Flash 6 Hz
Flash 12 Hz
OFF
ON
Internal power, initialising OK
Initialisation progressing
Initialisation error
No Ethernet link
Good Ethernet link
Ethernet data is transmitted or received, traffic indication
10 Mbit/s
100 Mbit/s
1000 Mbit/s
Half duplex
Full duplex
LINK/SPD
DPX
(TX only)
SFP Transceivers
The unit supports Westermo labelled transceivers only. See Westermo's modular
transceivers datasheets 100 Mbit and 1 Gbit for supported SFP transceivers. See
Transceiver User Guide "6100-0000" for transceiver handling instructions.
100 Mbit Tr
x seri
RedFox, Lyn
l solution
provide optima
… Wide choice to sions
• 1000 Mbit/s ver nnector type
cifications
• Standard LC co
vironmental spe 5°F)
t Westermo en
to +18
… Verified to mee nge –40 to +85°C (–40
• Temperature ra ntee quality • Coded to guara
olutions
ivers for many s .2 mi)
t transc
Differen
…
e up to 2 km (1
i)
• Multi mode fibr e up to 120 km (74.5 m
0 km (74.5 mi)
• Single mode fibrbre transciversup to 12
• Bi-directional fi nsceiver s
• Gbit copper tra
ansceivers
x series and
ODW-700
seri
es
… Wide choice t
o provide opti
• 100 Mbit/s vers
mal solution
• Standard LC co ions
… Verified to mee nnector type
• Temperature rt Westermo environm
ental specificat
• Coded to gua ange –40 to +85°C (–
ions
40 to +185°F)
rantee quality … Different trans
civers for man
• Multi mode fib
y solutions
• Single mode fibre up to 2 km (1.2 mi)
• Bi-directional fi re up to 120 km (74.5 m
i)
• 100 Mbit copp bre transciver sup to 120 km (74.5 m
er transceivers
i)
User Guide
6100-0000
Componen
t Recognition
Eye Safety:
EN 60825-1
Class 1 laser
The Wester
complies
mo range of S
applications.
LC connectorsmall Form-factor Plug
gable (SFP) tran
are used as sta
These transcei
sceiver s cover
ndard due thei
vers have been
s versions suita
plications. r small size.
Recognition
ble for 10/100
Component
le for Gigabit ap of different Westermo pro verified to meet the Mbit/s Wester
rs versions suitab
ducts in harsh certified versio
ransceivers cove
industrial appl mo environmental spe
ns have been i
nge cificatio
luggable (SFP) t
ications. The tra
nstalled.
Version
operate in a ra
s are available w
all Form-factor P
nsceivers are c n and can operate in .
ification and can
a range on that mo range of Sm dard due their small size
ith different wa
oded to allow c
nfirmatiand 13
10 nm The Wester
ironmental spec
allow co
ve leng
onfirmation tha
as stan
version
mo env
ded to th inclu
re used
for both singl
the Wester
a single fibre c
t nsceiver s are co
LC connectors a
e (9/125) and ding 1550 nm for extr
erified to meet ions. The tra
ore is available
eme di
multimode cab
ers have been v harsh industrial applicat
a Bi-Direction
(74.5 mi) les (50/125 an stances upto 120 km These transceiv
al (BiDi) trans
ducts in
(74.5 m
ces upto 120 km
ly d 62.5/125). In
ceiver can be u
Westermo pro
extreme distan
applications w i) ations where on
alled.
of different sed.
ing 1550 nm for
here only s have been inst
62.5/125). In applic
Interfaces
h includ
version
125 and
ve lengt
certified
rent wa
ode cables (50/
ailable with diffe
sed.
125) and multim
Versions are av
sceiver can be u
r both single (9/
iDi) tran
rsion fo
How
tional (B
far can we
Bi-Direc
and 1310 nm ve
get with transc
re is available a transceivers
eivers
a single fibre co
The different t
we get with
can
ranscei
ith an far
ver options are
How
indicative rang
s are marked w
marked with e as a part of t
cription. ansceiver option
an This is the spe
he transceiver transceiver des
The different tr
cified distance description.
iver is used as a part of the
Interfaces
in 100 Mbit ap
when the tran
hen the transce
indicative range
plications.
sceiver is used ified distance w
This is the spec
For the ODW
ions.
series the ma
) can be in Gbit applicat
calculated with
ximum distanc
um distance (km
the formula: e (km) can be eries the maxim
For the ODW s
Power budget
he formula: (dB) – signal l
nuation calculated with t
(db) per km.
oss (dB) / fibre
(dB) / fibre atte
attenuation B) – signal loss udget (d
Power b
Signal loss =
TX
splice attenua
of splices + contion x number
(db) per km.
nector attenua
ion x number
of
margin.
tion
splices
attenuat
RX
x
safety
number
splice
+
+
conSplice, connect
of connectors
Signal loss =
of connectors
+ safety margin.
on article
or and fibre
ion x number
attenuation
data sheets.
ion can be found
nector attenuat
can be found
r and fibre attenuat
on article
Splice, connecto
By calculating the maximum
power data sheets.
distance based
budget a LC2 ance based on RX
multimode tra
on power te e maximum dist
up to 5 km (3.
nsceiver can o
eiver can opera
By calculating th
TX
1 mi).
perate ultimode transc
budget a LC2 m
mi).
up to 5 km (3.1
1 complies
EN 608251 laser product
product
SFP
Transceivers
© Westermo Teleindustri AB
RedFox, Lyn
eivers
00 series
Gigabit Transc
es and ODW-7
Eye Safety: Class
www.westermo.com
09_EN_REV.
1Gbit_15
Transceivers
– A Beijer Electronics
Group Company
Transceivers
www.westermo.com
100Mbit_1510_E
N_REV. B
– A Beijer
Electronics
ESD Protection
Group Company
B
www.westermo.com
6644-2240
15
Mounting
This unit should be mounted on 35 mm DIN-rail, which is horizontally mounted on a
wall or cabinet backplate. Snap on mounting, see figure.
CLICK!
Removal
CLICK!
Press down the black
support at the back of the unit, see figure.
Cooling
This unit uses convection cooling.
To avoid obstructing the airflow
around the unit, use the following
spacing rules. Minimum spacing 25 mm
(1.0 inch) above / below and 10 mm
(0.4 inches) left / right the unit.
Spacing is recommended for the use
of unit in full operating temperature
range and service life.
16
10 mm *
(0.4 inches)
25 mm
* S pacing (left/right) recommended for
full operating temperature range
25 mm
6644-2240
6644-2240
17
18
6644-2240
6644-2240
19
Westermo • SE-640 40 Stora Sundby, Sweden
Tel +46 16 42 80 00 Fax +46 16 42 80 01
E-mail: info@westermo.com
www.westermo.com
Sales Units
Westermo Data Communications
China
sales.cn@westermo.com
www.cn.westermo.com
France
infos@westermo.fr
www.westermo.fr
Germany
info@westermo.de
www.westermo.de
North America
info@westermo.us
www.westermo.us
Singapore
sales@westermo.com.sg
www.westermo.com
Sweden info.sverige@westermo.se
www.westermo.se
United Kingdom
sales@westermo.co.uk
www.westermo.co.uk
Other Offices
For complete contact information, please visit our website at www.westermo.com/contact or scan the QR code
REV. F 6644-2240 2017-05 Westermo Teleindustri AB, Sweden