Gigabitowy switch 8-portowy UTP3-GSW0806-TP150

8 Ports Full Gigabit
Managed PoE Switch
User Manual
Preface
The user manual mainly introduces the product shape, product
positioning, hardware installation, Web management and other
related information.
Illustration
(1)Format of Graphics Interface
Format
< >
[ ]
Description
“<>”means button name, such as “click <Confirm> button”.
“[ ]”means window name, menu name and data table, such as“pop out [New
user] window”.
“/”is used to seperate Multi-level menu. Such as [file/new/folder] multi-level
/
menu [file] menu [new] sub-menu [folder] menu option.
(2)Various Signs
Caution
Instruction
Improper operation may damage the device or cause data loss.
Supplemental instruction for operation contents.
Content
1 Product Introduction
1.1
1.2
1.3
1.4
Overview
Product Feature
Board Diagram
Specification
2 Installation
2.1 Shipping List
2.2 Installation Precautions
2.2.1 Safety Precautions
2.2.2 Installation Requirements
2.2.3 The Requirements of Electromagnetic Environment
1
1
1
2
3
4
4
4
4
5
5
6
2.3 Installation Way
2.3.1 Rack Installation
2.3.2 Workbench Installation
2.3.3 Wall-hung Installation
6
7
7
2.4 Cable Connection
2.4.1 Device Connection
2.4.2 Configuration Cable Connection
2.4.3 Power Cable Connection
9
9
9
9
3 Function Configuration Guide
10
3.1 Computer Requirements
10
3.2 Set up Network Connection
3.2.1 Set Static IP for the Management Computer
3.2.2 Confirm the Network Connection by Ping Command
3.2.3 Cancel the Proxy Server
10
3.3 Web Page Configuration Guide
3.3.1 Start and Login
3.3.2 Change Language
3.3.3 Common Buttons Introduction
3.3.4 The Default Configuration
3.3.5 Web Users Timeout
3.3.6 Backup System Configuration Information
3.3.7 Restoring the Configuration Information
3.3.8 Quit
10
12
12
13
13
14
15
15
17
17
17
17
4 Web Management
4.1 System Status
4.2 Port Configuration
4.2.1 Port Settings
4.2.2 Port speed limited
4.3 VLAN Setting
4.3.1 VLAN Configuration
4.3.2 VLAN forwarding
4.4 Trunk Management
4.4.1 Trunk
4.4.2 RSTP
4.5 Port Security
4.5.1 Static Address Latch
4.5.2 802.1X certificates
4.6 Web Management
4.6.1 SNMP Setting
4.6.2 Email Alarm
4.6.3 Port Mirror
4.6.4 Multicast Snooping
4.7 Network Statistics
4.7.1 Network Statistics
4.7.2 MAC Address
4.8 System Management
4.8.1 IP Address
4.8.2 User Management
4.8.3 Log Information
4.8.4 File Management
4.9 PoE Management
4.10 QOS Management
4.10.1 QoS Setting
4.10.2 DSCP/ TOS QoS
18
18
19
19
21
22
22
24
24
24
26
29
29
30
32
32
33
35
36
37
37
38
39
39
40
41
42
43
45
45
46
1 Product Introduction
1.1 Overview
1.3 Board Diagram
Front panel
The switch with 8 Gigabit PoE+ Ethernet ports, 4 Gigabit uplink Ethernet
Uplink Gigabit Optical Fiber Ports(Combo)
ports, and 2 Gigabit optical SFP ports (Combo ports) is a full Gigabit managed
Ethernet Switch. The switch provides up to 4Mbit cache, Support 4K highdefinition video transmission. Besides, the 8 downlink PoE ports support
Reset Hole
Uplink Gigabit Ethernet Ports
Power LED
Mode Button
IEEE802.3af/at standard. PoE output power of single port is up to 60W and total
Combo
output power is up to 135W. It features total power display, one-key CCTV mode,
Web-based PoE management, and L2 characteristics, such as VLAN、QoS、
STP, etc. It fully satisfies the needs of security video surveillance and Ethernet
Combo
project.
Downlink Gigabit PoE Ports
Console
LEDs
Mode LED
1.2 Product Feature
POE Power LED
Broadcom chip; Buffer reaches 4Mbit, Support 4K high-definition video
transmission;
PoE function: Fully support IEEE802.3 af/at standard, each port
supports max. 60W PoE output, total machine max. 135W PoE
Caution
output, support total power consumption alarm and indicate;
Support Web-based network management, support VLAN, QoS, RSTP,
SNMP etc. network function;
One-key CCTV, 1~8 downlink ports only can communicate with uplink
ports in CCTV mode, which can restrain network storm;
Operating modes(Default,CCTV,Simple) can be switched by
Mode Button.
Back panel
6KV surge immunity, 8KV ESD protection and anti-interference ability;
Quick installation, easy operation, convenient for desktop and standard
19-inch rack installation. The lock design of AC connector make
connection more reliable.
Grounding
AC Power
Input
Caution
Device must be connected with lightning protection grounding;
Otherwise protection level will reduce; Please use above No.20
wire to connect the grounding terminal.
1
2
1.4 Specification
2 Installation
Description
Item
Power
Power Supply
Mains on load
Voltage Range
AC 100 ~ 240V 50/60Hz
Consumption
150W
1~8 downlink PoE ports: 10/100/1000Base-T PoE
Ethernet Port
Network
Connector
0~100m
configured).Whole machine ≤135W
IEEE802. 3,IEEE802. 3u,IEEE802. 3ab, IEEE802. 3z,IE
P lease check the following items before installation, if any missing, please
contact your local dealer.
EE802. 3af/at
Switch Capacity
24Gbps
17.9Mbps
Packet Buffer
4Mb
MAC Address
8K
CCTV Mode
(1)Realize the communication insulation among
downlink ports;
(2) Auto- identify and limit network storm as low as
2 Mbps
Simple Mode
No management function
Management
Management L2 + PoE
ESD
6KV Contact discharge
8KV Air discharge
Protection
2.1 Shipping List
Each port ≤30W(Default PoE of port 1=60W, able to be
Packet Forwarding
Rate
Mode
Environmental
caused by unauthorized disassembly is not covered under warranty.
11~12 uplink Combo ports:1000Base-X SFP
Network Standard
Management
Anti-counterfeiting label is attached to switch's cover. Product damage
9~12 uplink ports:10/ 100/1000Base-T
Transmission Distance
PoE
Network Switch
Caution
Item
Name
Quantity
Unit
1
Device
1
pc
2
AC Power Line
1
pc
3
Accessory
1
pc
4
User manual
1
pc
2.2 Installation Precautions
To avoid device damage or personal injury by improper use, please observe the
following precautions.
Execute:IEC61000 + 4 + 2
Lighting Protection
6KV Per: IEC61000-4-5
Working Temperature
-10℃~ +45℃
Storge Temperature
- 40℃~+ 85℃
Humidity(noncondensing)
0 ~ 95%
Dimension(LxWxH)
442mm×215mm×44mm
Material
Sheet Metal
Color
Black
Weight
1.5kg
2.2.1 Safety Precautions
Instruction
This is level A product, which may cause radio disturbance in living
environment. Users may need to take corresponding and effective
measures to solve the problem.
Mechanical
Products are subject to change without prior notice.
3
4
Pull out the power plug before cleaning the switch. Do not use wet cloth nor
liquid to wipe or wash the switch;
Do not leave the switch close to water or wet place so as to prevent water or
2.3 Installation Way
There are 3 installation ways: rack, workbench and wall-hung installation.
dampness from entering into the switch;
Make sure the switch work in a clean environment. Excessive dust may
cause electrostatic adsorption, which will affect the equipment life and cause
Caution
Please pull out the power plug before installing or moving the switch.
communication failure;
The switch will work normally under the correct voltage. Please ensure the
Grounding and anti-lightening can greatly increase the protection level of the
switch. please connect the grounding terminal to the earth area by using at
voltage indicated on the switch corresponds to the power voltage;
least wire 20.
To avoid the danger of electric shock, please do not open the switch case.
Do not open the switch case even if the switch is powered off;
The accessories (including but not limited to power cables, etc.), which can
Instruction
The diagram is for reference only, the products are subject to actual
be used for the switch only, is prohibited for other applications.
product.
2.2.2 Installation Requirements
The device should work in indoor environment to avoid thunder stroke. It is
important to obey the following requirements
no matter you install it in the
2.3.1 Rack Installation
cabinet or on the workbench directly:
Enough space (larger than 10cm) for air outlet so as to facilitate the
Installation process:
heating dissipation; Good ventilation system for cabinets and workbench
(1) Check rack with good grounding and stability;
is preferred;
(2) Use screws to fit hangers at the device board side; Ensure the Cabinet and workbench is sturdy enough to support the
switch and it’s accessories’s weight;
Cabinet and workbench with good grounding is preferred.
2.2.3 The Requirements of Electromagnetic Environment
When it is working, the switch may be affected by external interference outside
the system through the ways of radiation and conduction. Please pay attention
to the followings:
AC power supply is TN system, so it is necessary to use single phase power
socket (PE) which can protect ground wire so that the filter circuit
can
Figure 2-1 Install hangers diagram
effectively filter out the power grid disturbances;
The switch should work far away from high-power radio transmitters, radar
transmitters, high-frequency devices;
(3) Put the device on the rack’s bracket and move the rack along the slot to
proper position ;
Use electromagnetic shielding if necessary, such as shielded cable;
(4) Use screws to fit the installation hanger at rack’s fixed slot, make sure the
Interface cables should be arranged indoor rather than outdoor to prevent
device is installed at rack’s bracket steadily.
over-voltage or over-current damage to the signal port.
5
6
Figure 2-3 Hangers installation diagram
(2) Drill holes on the strong position of wall and then drive the rubber plug into
the hole;
(3) Drive these screws into the hole for the rack and fix the product by aiming at
Figure 2-2 Install switch to the rack
the rubber plug .
Instruction
This product’s fixing hangers are just to fix the switch rather than support
it. Use brackets under the device (fixed to the rack) to support switch
when install the switch to the rack.
2.3.2 Workbench Installation
You can put this product on clean, stable, grounded workbench. The installation
Figure 2-4 Fix the switch on wall
procedure as below:
(1)Carefully put the device upside down, clean the grooves on the chassis
backplane with soft cloth to make sure there is no oil or dust in it;
(2)Remove the stickers on the foot pad, paste the foot pad in backplane groove;
(3)Carefully put the device upright on the workbench.
2.3.3 Wall-hung Installation
You also can put the product on clean, steady vertical wall. Installation
procedure is below:
(1) Use the screws to fix the hangers;
7
8
2.4 Cable Connection
3 Function Configuration Guide
2.4.1 Device Connection
3.1 Computer Requirements
Use cross network cable or cross-over cable to connect PC or
other device with switch's Ethernet port;
2.4.2 Configuration Cable Connection
Use a network cable to connect Ethernet ports except the console port ( Notice:
The VLAN ID of this Ethernet port must be 1) with management PC, and use
management PC to configure the PoE switch.
Make sure the management PC has already been installed with Ethernet adapter;
Use network cable connect Ethernet ports with network card of PC(Except the
console port).
3.2 Set Up Network Connection
Instruction
(1) You need to set the IP of the PC and the switch in the same
network segment. The default IP address of the switch is 192.168.1.200,
network gate is 255.255.255.0.
(2) The port to connect management PC for Web setting must be
management VLAN. By default, management VLAN is VLAN 1,and each
port of the switch is VLAN1.
(3) If you need to connect the remote network, please make sure the
management PC and the router can do the job above.
(4) This product can't assign the IP address for the management PC, you
need to set the management static IP by yourself .
Figure 2-5 Connect configuration cable
2.4.3 Power cable Connection
(1 ) Connect one side of switch’s power cable with the switch's AC power port,
and connect the another side with external AC power socket;
(2)Turn on the power ,c heck if switch's AC power LED is on, that means
3.2.1 Set Static IP for the Management Computer
Operation steps (take Windows XP as sample):
(1) Click <start> to enter the [start]
menu, select “control panel”. Double
click “network connection” icon,
power connected correctly;
double click the “local connection”
(3)Use the power plug snap to jammed the AC Power cable.
icon, pop out “local connection
status” window.
Figure 2-6 Connect power cable
9
10
(2) Click <property> button, enter "local
connection property" window.
3.2.2 Confirm the Network Connection by Ping Command
Operation Steps below:
(1) Click <Start> button to enter [Start]
menu, select [Run], pop out the dialog.
(2) Input "ping 192.168.1.200", click
<confirm> button. If there is equipment
response show in the pop out dialog,
that means network connection succeed,
otherwise please check if the network
connection is correct.
(3)Select "Internet protocol (TCP/IP),
click <property> button, enter”Internet
protocol (TCP/IP) property” window.
3.2.3 Cancel the Proxy Server
Select “ use the IP address below”
If this management PC use proxy server to visit the internet, then you must prohibit the
button, input IP address ( use arbitrary
proxy service, following is the operation:
value between 192.168.1.1~
192.168.1.254, besides 192.168.1.200)
and the subnet mask(255.255.255.0).
(1) In browser, select [ tool/Internet
option] enter [Internet option] window.
Click "OK" to finish the configuration.
Instruction
DNS server address can be empty or be filled in with the real server
address.
11
12
(2) Select “connection” tabs in [Internet
option] window, and click [LAN Setting]
button.
Caution
Please follow the steps to check if the switch is installed correctly:
(1) Whether the physical connection of the equipment is correct?
Use network cable to connect the product’s Ethernet port(except the
console port) with managed computer network card, and ensure the link
LED of the port is on.
(2) Whether the computer TCP/IP agreement setting is correct?
Your computer's IP address must be 192.168.1.x (x range is 1 ~ 254 and x
can not be 200, otherwise it will conflict with the product IP address
192.168.1.200 ), subnet mask: 255.255.255.0.
(3) Make sure the “Use proxy server for LAN”option is not selected. If selected, please
(3) Whether the computer's port VLAN ID is 1?
cancel it and click <yes> button.
By default, the management VLAN is VLAN 1, same as each port of switch.
The menu bar has the following options: [System Status], [Port Configuration],
[VLAN Settings], [QoS management], [link management], [Port Security],
[network management], [Network Statistics], [System management], [Exit] and
After inputting the correct password, click <Login in>, the browser will display
drop-down menu bar of the "language switching function". Click a option to
the product Web management page as the picture below:
make corresponding setting. The following will explain the function of each
option.
3.3 Web Page Configuration Guide
The browser version recommend:IE7 and later, Firefox browser, Chrome, 360
browser (IE7 and later).
3.3.1 Start and Login
This product web default IP address:
192.168.1.200, subnet mask:
255.255.255.0, administrator
account: admin, password: admin.
After installing the equipment
Web management page diagram
correctly and setting up the computer,
open the browser, input the switch
default address in the browser
address bar: http://192.168.1.200 ,
then press the Enter key, the user
login page will show in front of you as
3.3.2 Change Language
As shown below, in the upper right corner of the Web page, click on the dropdown menu bar, select [Chinese] or [English], to complete Web language
switching.
follows:
13
14
Table 3-2 Default Configuration
Options
Default Configuration
Web English language switching page diagram
Username / password
admin/admin
IP Address
Subnet Mask:255.255.255.0
MAC address table aging
time
300 Seconds
Ports Status
Enable
Ports Speed Rate
Auto-negotiation
Port duplex mode
Auto-negotiation
Flow Control
Open
Trunking
Port does not converge
Port Speed Limitation
No limitation for Speed
Port Link Type
Access
Management VLAN
VLAN 1
VLAN Function Mode
Port-based VLAN
3.3.3 Common Buttons Introduction
IP Address:192.168.1.200
System
Table 3-1 Web commonly used function buttons introduction
Button
Help
Function
Open the online help page of Settings page to display the help
information for current page.
Confirm
Submit the input i nformation and confirm the information the
current system provided.
Cancel
Cancel the current configuration input
Return
Return to the previous page
New page
Create a new project of the current page
Select all
Port
Select all the ports of the current page
VLAN
Refresh
Refresh the current configuration page
Delete all
To delete all configuration items the section selected
3.3.4 The Default Configuration
The following table lists some important default configuration of the switch, all
features will be described in details in following chapters. The default
MAC Binding
No Binding
RSTP
RSTP Function
Close
Network
Management
SNMP
Close
configuration is for most cases. Please reconfigure if the default configuration
does not match the actual requirements.
15
16
3.3.5 Web User Timeout
When you have left the Web setting page for a while, the system will log out and
4 Web Management
return to the Web dialog box due to system time-out. Please log in again if you
4.1 System Status
want to proceed the operation.
The meaning of specification in the page shown as below.
Table 4-1 Specifications description
Instruction
Specification
Web page login timeout setting defaults to 5 minutes.
Description
Display different time zones around the world. For example,
Word Time Zone
select Automatically Adjust Daylight Saving Time in daylight
saving time zone.
3.3.6 Backup System Configuration Information
Click <Backup> button to select the configuration file backup path, click <OK>
Time
Configuration
You can select local time or use NTP
button to save the current configuration for the computer. The configuration can
NTP is used when all the equipment clocks in the network
be restored through the document [* .cfg] .
have to be kept the same so as to ensure the accuracy of the
NTP Sserver
3.3.7 Restoring the Configuration Information
Click <Browse> button, select previous backup file[* .cfg], click <Recover>
clocks. Enter the correct NTP server’s IP address to start
the setup.
System Time
The current time of the device, if you did not get the NTP
updated time, then it will start to count from 0:00,1970.
button. The configuration information stored in the backup file will be restored to
the device, the configuration takes effect after the device restarts automatically.
PC Time
Computer current time
Network identification device used to facilitate the
3.3.8 Quit
Click the [Exit] menu item in navigation bar, return to the system status page,
Device Name
integrated management tools such as SNMP to judge
different equipment.
Contacts
Equipment maintenance personnel’s Contact Information
the login box will be popuped out automatically till the next click on the page.
Contact Address Equipment maintenance personnel’s Contact Information
Hardware address of the device is unique since it is
MAC Address
determined by the length of 48 bits (6 bytes), Hexadecimal
digits.
Pay attention to software release limit for the hardware
Hardware,
Software Version
version. There are more functions in the updated software
version, some of which have new requirements about
hardware version.
Running Time
17
The time period since equipment has been running. when
the device is restarted, the time needed to be recalculated.
18
4.2 Port Configuration
Specification
Port Enable /
Disable
4.2.1 Port setting
panel silkscreen port and Web port corresponding table
Description
Display the data forwarding of the port. If a port is off, you
can not forward the data. Enabled by default.
Display the port configuration’s speed rate, including 10M,
100M, 1000M, auto-negotiation. It defaults to Auto-
Port Speed Rate negotiation, which means the port can automatically and
UTP3-GSW0806-TP150
Web Port
1
3
5
7
9
11
directly connected the device on the other side to negotiate
Silkscreen Port(up)
1
3
5
7
9
11
Web Port
2
4
6
8
10
12
the port speed. It defaults to Auto-negotiation mode.
Display the port configuration’s duplex status, including full-
Silkscreen Port(Down)
2
4
6
8
10
12
Duplex Mode
duplex mode, half-duplex mode, and auto-negotiation
mode. It defaults to auto-negotiation mode.
Choose whether to enable the function of flow control
On the [Port security / Port Settings] page, you can observe all the current
When two switches have enabled the function of flow
switch port status information and can set [Port Enabled], [port rate], [Flow
control, if one of the two switches has be congested, it will
Control], [Port range],shown as figure 4-1.
send message to the other switch to notify it to temporarily
Flow Control
stop sending messages or slow down the sending speed.
After receiving the message, the other switch will stop
sending or slow down the sending speed of messages so as
to avoid packet loss and ensure normal operation of
network services.
By default, the flow control function of the port is enabled.
Configuration direction:
To set the port 1-10 to 100Mbps half duplex mode, and disable the flow control
function, please follow these steps:
To set the port 1-10 to 100Mbps half duplex mode, and disable the flow
Figure 4-1 Port configuration
The specification meaning in this page shown as below
Table 4-2 Specification
control function, please follow these steps:
Enter 1-10 (or click on the box in front of the port) in the range of ports;
Click the port speed drop-down menu to select 100Mbps;
Click dual- duplex mode on the drop-down menu to select half-duplex;
Click flow control the drop-down menu to select the Disable ;
Click Edit;
Operation ends.
Instruction
1-8 port port rate of 10/100 / 1000Mbps adaptivefor
11-12 ports for uplink optical port, at fixed rate of 1000Mbps.
9-12 port is fixed uplink Ethernet ports at a rate of 10/100 / 1000Mbps
adaptive.
19
20
4.3 VLAN Setting
4.2.2 Port speed limit
The Equipment provides port-based entry speed limit. Users can restrict
Switch supports two VLAN modes:
every port traffic flows or cancel port flow restrictions . Users can choose a
(1) Port-based VLAN mode: define VLAN members according to device port.
fixed rate, the range is:downlink ports 1~1000Mbps, uplink port 1~
After you specify the port to a VLAN, specified VLAN Packets can be forwarded
1000Mbps, Accuracy is 1Mbps. Port restrictions including Unicast
by the port.
packets,Multicast packet and broadcast packet .
(2) 802.1Q VLAN mode: Defined by IEEE802.1Q protocol. Process the packets
In [ports setting/ port speed limit] page , could modify [port speed limit]
by identifying the packets tags.
function setting , as the figure 4-2 show.
4.3.1 VLAN Configuration
On [VLAN / Port VLAN] page, you can observe the VLAN settings of all the
current port switch and can set several functions such as [Port range], [Link
type], [Default VLAN ID], [VLAN forwarding list], [vlan-untagged mark list] , as
shown in figure 4-3.
Figure 4-2 Port speed limit
The meaning of the parameters on this page are as shown below.
Table 4-3 Parameter description as the following table:
Specification
Bandwidth Settings
on / off
Turn on or off the port speed limited, the default is off
The meaning of the parameters on this page are shown as below.
Table 4-4 Parameter description as the following table:
Port range
The port that need speed limited
Input rate
The max input rate of each port
Limited type
Figure 4-3 VLAN setting
Description
Parameter
Access :port, which is normally used for connecting
devices, only belongs to one VLAN. By default, all ports
Port limited type including all Unicast packets, multicast
Configuration direction:
Link Type
are Access ports.
Trunk : port belongs to multiple VLAN and can receive and
Such as c ontrol the rate of 1-5 ports to 50Mbps,limited type is Broadcast
send multiple VLAN packets. It is normally used to connect
packet。
network devices.
Turn on ports rate;
Input 1-5 in port range, input rate is 50,limited type is Broadcast packet.
Click save;
Operation finished.
Default VLAN ID
Enter the ID number which is needed to be divided.
(generally 1-4094)
VLAN Forwarding
VLAN packets can be transferred, other will be discarded.
list
VLAN untagged
mark list
21
Description
Port forwarded packets can be set in VLAN. Untagged
without a tag , but other can not.
22
Configuration Guide:
Caution
Such as if port 1-10 has connected to a switch respectively, it is necessary to
divided port 1-10 into VLAN 20.
Enter 1-10 within the port range(or click on the box in front of the ports);
Choose Trunk on the menu(Switches connection is generally used with
Trunk mode);
The default port VLAN and allowed VLAN must be existed VLAN.
4.3.2 VLAN Forwarding
On[VLAN / VLAN forwarding] page, you can observe the current port
Enter 20 to default VLAN ID;
VLAN forwarding information, shown in figure 4-4.
Enter 1-10 to VLAN forwarding;
Enter on VLAN flag list based on actual relationship (the receiving and
sending of packets for port is shown in Table 4-5);
Press Set to save the setting;
Operation finished .
Instruction
VLAN ID range is 1-4094, VLAN flag list must be in the range of VLAN
forwarding list.
Figure 4-4 VLAN forwarding
The page parameter description as the table shown.
Table 4-5 Port processing of transferring and receiving message.
Table 4-6 Parameter description
Received message process
Port Type
Access
Transferred message
Received message
without Tag
with Tag
VLAN ID
When the VLAN ID
VLAN Name
process
The default VLAN ID
and default VLAN
port for the packet with
ID is the same,
Delete message Tag
the corresponding
receive the packet.
before transferring it.
VLAN Tag.
Otherwise discard
Compare port default
VLAN ID to check
the VLAN ID, if yes, the
allowed to pass
default message with
through in the VLAN
port VLAN ID
ID, then receive the
corresponding VLAN
packet. Otherwise
Tag; if No, discard the
discard the packet .
packet.
23
VLAN ID needed to be changed
Change the VLAN name that need configuration
Configuration Instruction:
Such as revise VLAN20 name from sales department to financial
department.
Enter financial department to VLAN Name;
When the VLAN ID
Press Revise to save the setting;
and default VLAN ID
End.
is the same, remove
whether it is allowed by When VLAN ID
Description
Enter 10 to VLAN ID (or click on the box in front of the VID10);
the packet .
Trunk
Parameter
Received message
the tag and send the
4.4 Trunk Management
message. When the
4.4.1 Trunk
VLAN ID and default
TRUNK means port convergence, configure the software settings and
VLAN ID is different,
connect two or more physical ports to become a logical path to increase
and is allowed to
the bandwidth between switches and network nodes. The bandwidth merge
pass through the
of several ports provides an exclusive high bandwidth several times than
port, maintain the
an independent port.
original tag and send
On [LACP / TRUNK] page, you can observe the current port link
the message.
convergence information, shown in figure 4-5.
24
4.4.2 RSTP
4.4.2.1 RSTP Uses
STP (Spanning Tree Protocol) is established in accordance with IEEE
802.1D standard. It is developed for the elimination of the data link
layer loops in the LAN protocol. Devices running this protocol exchange
packets with each other to find loops in the network, and choose to
block some certain ports. This will eventually make the loop network
structure
into
a
loop-free
tree
pruning
network
structure.
Thus
it
prevents packet proliferation and infinite cycling in loop network, avoiding
declined processing capacity and receiving same messages repeatly.
Figure 4-5 Trunk link
STP contains two meanings, narrow meaning of STP is defined in IEEE
802.1D, board meaning of STP includs IEEE 802.1D defined STP and
various enhanced spanning tree protocol produced on the basis of STP
Instruction
Each convergence group supports up to eight ports.Port with the
following cases can not be added to an convergence group:
(such as RSTP protocol).
4.4.2.2 STP Basic Concept
(1) Port with 802.1X function;
(1) The root bridge
(2) The mirror port;
Network structure tree must have a root, then STP introduces the concept
(3) Port with MAC address binding.
of root bridge in. Only one root bridge and the root bridge will change
when the network topology changes, so the root bridge is not fixed.
Configuration Guide:
(2) The path cost
Such as connect the switch A’s 1-2 ports with switch
Path cost is a reference value for STP to select a link. By calculating the
B’s 1-2 ports
Enable a convergence group in switch A;
path cost of STP, STP chooses stronger links to block redundant links and
Select 1 and 2 ports;
cut the network into a loop-free tree topology.
Click Save;
(3) The port role
Switch B and Switch A are in consistent procedure;
Root port: responsible for forwarding data to the root port.
End.
Designated port: responsible for forwarding data to the downstream of
network segment or switch port.
Block Port: port suppressed by other's specific ports.
Caution
(4) Port status
In the same convergence group, the port speed, duplex mode, and
Forwarding: Forwarding user traffic, only the root port or designated port
basic configuration must be consistent.
have this condition.
STP consistent configuration, including STP ports on / off, STP
Learning: The switch builds the MAC address table according to user
priority, STP cost, whether to open loop guard and root guard, or
traffic received (but not forwarding traffic).
edge ports.
Listening: the completion of the root bridge, select the root port and
QoS configuration is consistent.
designated ports.
VLAN
consistent configuration, including permitted VLAN, the default
port of VLAN ID. Link type on the ports is consistent.
Blocking: Only BPDU is received and processed, no user traffic forwarded.
Disabled: consider blocking or link disconnection.
(5) The designated bridges and designated ports
The meaning of designated bridges and designated ports is shown in Table
4-7 below.
25
26
Table 4-7 Designated port status
Classification
Designated Bridge
Equipment connecting directly
For equipment
Designated Port
Port used by
with switch and responsible to
designated bridge to
transfer BPDU message to
transfer BPDU
switch
message to switch
Responsible to transfer
designated bridge to
Port used by
For LAN
Figure 4-6 RSTP
BPDU message to local network
transfer BPDU
segment equipment
message to local
The meaning of main parameters of the pages as below.
network segment
Table 4-8 Parameters description
4.4.2.3 RSTP Introduction
RSTP (Rapid Spanning Tree Protocol) is an optimized version of STP. It
Parameters
As the network bridge priority, network bridge and
Device priority
is"fast" because the delay is shortened under certain conditions when a
port is selected as the root port and designated port to enter to the
forwarding state, thus the time to reaching topology stability is greatly
reduced.
Instruction
which minimum bridge ID will become the root network.
Maximum
message lifetime
Changing port
status delay
Path expenditure
forwarding data.
Means the validity of a BPDU data package of a swtich
received from another switch.
The forward delay of a switch port status in transition
status(listening and learning).
Setting port path cost, only setting when port default path
cost on “off” status Port link cost, with port priority and port
ID form port ID to compare Value range 1~200000000
“0”means automatic check.
In RSTP, to ensure fast move of designated port: the designated port should
be an edge port or a port connected to point to point link. If the designated
network bridge MAC address combined as bridge ID, of
Sending message
The interval needed to sent a BPDU data packet.
interval
In RSTP, to ensure fast move of root port: the old root port of the device has
to stop forwarding data and the upstream designated port has to start
Description
The priority of port in network bridge, with port priority
Port priority
and port ID form port ID to compare. Default port
port is an edge port, the designated port can enter the forwarding state; if
priority is 128.
designated port is a port connected to point to point link, the device can
Switch port and switch connected directly, then this port
handshake with the downstream device to give immediate response to enter
forwarding state.
Point to point port
is P2P port, RSTP adopts negotiation mechanism for
P2P port so as to achieve quick transformation of port
status.
The network edge switch generally connects with terminal
On [LACP / RSTP ] page can observe the current port RSTP information
on the switch, shown in figure 4-6.
equipments, such as PC, workstation.To configure
Edge port
these terminal ports to Edge ports can achieve status of
transformation port without discarding Learning and
forwarding transformation course.
RSTP information Check RSTP information and port information
27
28
Configuration guide:
Parameters
Description
MAC Address
Static MAC address differs from the general dynamic MAC
address. Once a static address is added, the address will
remain in effect until be deleted and free the maximum aging
time limited.
Enable RSTP function to avoid broadcast storm caused by looped network
structure among switch A ,switch B and switch C 1-10 port.
Enable switch A,B,C RSTP function;
Enter 1-10 within the Port range (or click
box front of port)Equipment
priority, cycle of sending message, maximum lifetime of information,
default port status migration delay;
Path cost, enter "0" is automatically detected;
Port priority, choose “128”;
Point to point, choose“yes”;
Edge port, choose “No”;
Click save, operation finished.
Instruction
After setting RSTP, click “ RSTP information ” to check root bridge and
port information. The port recover time is around 30s by default, click
right key to refresh current status。
4.5 Port Security
VLAN ID
Port
Port-corresponding VLAN ID number
Select a static MAC address to forward port, you can only
specify one forwarding port.
Configuration Guidelines:
For example, when binding the port 10 of switch A with switch B, port 1 belongs
to VLAN20.
Enable static address latch function of switch B;
Enter the MAC address of switch B;
Enter VLAN ID with 20;
Enter port with 20;
Click Save;
Operation finished.
Caution
4.5.1 Statics Address Latch
Statics MAC address is to limit computer operation, the computer with binding
computer MAC and ports can not communicate with other ports, while other
computer can do that.
On [ Port security / Stastic address lock] page displays switch information of
This feature is a security mechanism which requires high attention to the
settings;
Do not use a multicast address as a enter address;
Do not enter the reserved MAC address, such as local MAC address;
For port which has already been added to an aggregation group, it is not
allowed to set binding function between port and MAC address.
statics address latch, as shown in figure 4-7:
4.5.2 802.1X certificates
Figure 4-7 Port security
The meaning of main parameters of the pages as below. .
Table 4-9 Parameters
29
IEEE 802.1X certification system adopted the "controllable port" and
"uncontrolled ports" logic functions. It can realize the separation of business
and certification. After passing certification, the business flow and the
certification flow separation, it has no special requirement for the following
subsequent packets. Business can be flexible, especially in develop broadband
multicast business, it has a lot of advantages. All the business are not
restricted by authentication.
802.1X Three Main Parts:
(1) Application supplicant:User and Client which want to get the
certification;
(2) authentication server:A typical example for the RADIUS server;
(3)Certification System authenticator:Between the end devices, such as
wireless access points, switches, etc We can play at the same time equipment
system and authentication server two characters, you can also use the
additional authentication server, at the same time support the billing system.
30
In [port security / 802.1X authentication] page, you can modify / 802.1X
Configuration Guide :
authentication function set, as shown in figure 4-8:
EX: Setting port 1-10 to compulsory licensing model, the maximum number of
users to 10.
Start using 802.1x Certification;
Ports Scope choose1-10, Control mode selection compulsory licensing,
maximum number of users input 10;
Click setting and save;
Operation finished .
Instruction
(1) Between the applicant and the authentication system using MD5 inquiry, do not support others;
(2) If the network connection properties without "authentication" option,
please select “attachment" - > "management tools" - > "component
Figure 4-8 802.1X certificates
services" - > “service", set "Wired AutoConfig" to "automatic";
(3) Billing server setup error will also lead the applicant cannot be
Table 4-10 Parameter Description
authenticated. No billing server does not need to set up
Specification
802.1X config
Description
On/Off 802.1X certificatin,default is off.
Regularly update 802.1X The certification cycle time, used to enhance the
the certificaiton security of authentication.
Radius Server
Equipment built in the Radius server, if choose internal
Radius of service,Applicants will only be used inside
the Raduis database users and password. If the use of
external Radius server need to fill in the authentication
server IP addres and Ports NO.If you need to use the
AAA billing system, fill in server setting IP address and
Ports No. Or Server setting IP address is Blank.
Radius Remote access authentication server, namely
certification authorization use,Set the IP
Authentication
server IP address address/domain is device can access to,The default port
is 1812.
shared key
Service port
Settings
control mode
For device access authentication server Shared
password string.
31
unless you use the internal authenticated server;
(5) When using the remote server, the administrator can access the remote
server, be sure to confirm equipment displaying "device address of the
gateway set up correctly, if use the domain name the DNS must be set
correctly.
4.6 Web Management
4.6.1 SNMP Setting
SNMP is used to ensure the management information transferred between any
two points, so that network administrators can easily retrieve information on any
node on the network to modify information, fault search, troubleshooting,
capacity planning and report generation.
SNMP contains NMS and Agent, of which NMS is a workstation running the
server-side program, while Agent is the client software running on net work
Server implementation is the function of billing, set the
IP address/domain is equipment can access,Default
Ports is1813.
message from NMS, it starts to read or write and generate response packets
Compulsory licensing model respectively, and the
and send the response packets back to the NMS.
automatic mode, mandatory unauthorized mode.
Port Control mode MAC Based.
Max ID list
(4) All upink or downlink ports must be forced through the authentication, or
prohibit the use of certification ", otherwise can't use the remote server,
Scope :1-4096.
device. NMS can send request message to Agent, after Agent receive request
On the [Network management / SNMP Settings] page, you can enable /
disenable the SNMP service ad set the community name, etc as shown in figure
4-9.
32
Figure 4-10 Email alarm
The meanings of main parameters of the pages are as below table .
Table 4-12 Parameters description
Figure 4-9 SNMP Schematic configuration
Parameters
The meaning of main parameters of the pages are as below.
Mail Server
Table 4-11 Parameter description
Parameters
SNMP Gateway
SNMP version
Read-only
Description
Agent send the network IP address from receiver who send
abnormal alert.
Only support V1/V2/V3 version.
A SNMP community named after a string, the group only has
community name permission to operate.
Read-write
A SNMP community named after a string , the group has
Description
The host computer’s IP address or the host computer that
provide POP3 mail delivery service to our devices.
Email Accounts The account name for logging in email server.
E-mail
Password
Recipient
The password to the account name for logging in email sever.
The email address used to inform recipients of abnormal
Address
Email Reply
Address
events.
The email address that can help solve abnormal events.
community name permission to Get and Set operations.
Mail interval
Caution
Community name: used to define the relationship between the SNMP
manager and an SNMP agent. If the community name SNMP packets
have not been recognized by the device, the packet is discarded. You can
The interval time that regularly send log and weekly reports.
Configuration guidelines:
If a switch can not send message out, it should send alarm messages to the
specified 163 mailbox.
use the standard community name (public or private) or a user-defined
Enable Email alarm function;
group name.
Enter your serve smtp.163.com in the mail server;
Enter the account ***@163.com in your email account to log in email server;
4.6.2 Email Alarm
Enter email password;
Receipt email address should input email address of the email receiver
The device if it is running an event supervision, the supervision sends an alert
***@163.com;
message to defined mail recipients when something wrong about defining time
Enter recipient or webmaster email in email address,The address is
and some abnormal event occurs,. Supervision also periodically send all log
***@163.com;
messages to predefined recipients.
Mail intervals is 12 hours;
On the [Network management / Email alarm] page, you can turn on / off Email
Click Save to finish the procedure.
alarm service, shown in figure 4-10.
33
3
34
Configuration Guidance:
Caution
Such as port 3 monitor port 2 Import data traffic
Some email service system requires that the "email reply address"
Open Port Mirror;
should match the"email account”; when sending system test email, the
Input3 on monitor port, input 2 on mirror Port, Data collection selected from
password should be in plain text. The test mail can not be sent if the
import data ;
password is "*".
Press save after setting;
Finished.
4.6.3 Port Mirror
Port mirroring refers to copying the monitor port data to a designated monitoring
port ,For data analysis and monitoring ,The Ethernet Switch support multiple
Instruction
(1)This feature must be turned off in normal use, otherwise, all based on
mirroring to one mirroring, which Copy packets from multiple ports to a monitor
advanced management capabilities port can use such as RSTP, IGMP
port, User can also specify the direction of monitored packets, such as only
SNOOP;
monitor designated ports message. Equipment using port mirroring group way
to configure port mirroring,Every port Mirror include monitoring port and be
(2)Mirroring only handles normal packet FCS, can not handle all kinds of
erroneous data frame;
(3)To replace the mirror port or monitor port, directly input monitoring port
monitored port.
number or Mirror port number, and then click Setting.
In[ network management/ port Mirror ] page, which could modify [port Mirror]
function setting ,as the figure 4-11 show
4.6.4 IGMP Snooping
Switch IGMP membership report message to the router IGMP membership
through intercepting mainframe. Form Corresponding relationship between
group members and switch interfaces ; Switch transfer multicast packets be
received to member group ports according to Correspondence.
[Network Management/ IGMP Snooping] Page, Modify and setting [IGMP
Snooping] function as the figure 4-12 show .
Figure 4-11 Port Mirror
The page parameter as the sheet show:
Table 4-13 Main parameters Description
Parameter
Description
Port Mirror on/off Turn on/off Port Mirror Function ,Default is off
Monitor Port
Mirror Port
Data Collection
35
Port for monitoring, the port display data is designated
direction
Be Monitored ports, these ports collect designated
direction data from be monitored ports
Figure
4-12 IGMP Snooping
Specifies the monitor port data direction was divided into
Multicast Snooping Parameter meaning as shown in the Table:
"all data", "data import" and "export data" three options
Table 4-14 Major Parameter Description
36
Parameter
Description
IGMP Snooping
Opening and Closing Multicast Snooping function ,Default
On/Off
is Close.
IGMP Inquiry
Open IGMP Multicast Inquiry function
IGMP Query
Open IGMP Qurey Function, Check Existing Multicast
interval
Members for one time
Member Existing
Time
group forwarding
How to transfer those ports When the received multicast
address does not exist in the address table
table
Receive Frame singlecast
Package
Receive Frame multicast
Packeage
Receive Frame Broadcast
Package
The longest time of equipment Existing multicast Member
survival time
Unknown multicast
Parameters
Receive Frame Error
Package
Send Frame Singlecast
package
Send Frame Multicast
Package
Instruction
Send Frame Broadcast
Package
(1)PC's Ethernet port should be allocated only one IP address is
recommended;
(2)Network is best not to have multiple IGMP inquirer;
Send Frame Error Package
Description
The r eceived address is the number of packets in
the unicast address.
The received address is the number of packets in
the multicast address.
The sent received address is the number of
packets in the broadcast address.
Error package numbers due to various wrong
reasons sent and received by ports.
The sent address is the number of packets in the
unicast address.
The sent address is the number of packets in the
multicast address.
The sent address is the number of packets in the
broadcast address.
Error package numbers due to various wrong
reasons sent and received by ports.
(3)Please choose all the port If you are unsure forwarding relationship to
unknown multicast group
4.7.2 MAC Address
MAC (Media Access Control) address is the hardware identification of network
4.7 Network Statistics
equipment. Switches could transfer message according to MAC address. MAC
4.7.1 Network Statistics
MAC address table, in which, the MAC address corresponds to switch ports.
address is unique ,which ensures the correct message. Every switch maintains a
On the [Network statistics / Flow statistics] page, you can view the number of
data packets and bytes transferred for each port, shown in figure 4-13.
The switch could decide to filter this data frame or transfer data frame to
corresponding port according to MAC address table when the switch receives
data frame. MAC address is the basic and premise for data frame fast forwarding.
On [Network statistics /MAC table] page, you could check MAC address of each
port, as the figure 4-14 shows:
Figure 4-13 Traffic statistics
The main parameters of the above illustration are described in the table below.
Table 4-15 The description of the main parameters
Figure 4-14 MAC address table
37
38
The main parameter description are shown as the table.
Table 4-16 Main parameter
On this page, you could modify or add one user with password . as figure 4-16.
Parameter
Inquiry by physical
port
Inquiry by MAC
address type
4.8.2 User Management
Description
Enter detailed physical MAC address to check.
MAC address type consists of static MAC address and
dynamic MAC address.
Figure 4-16 User management
Caution
Multicast MAC address table is displayed in IGMP snooping table, all these
The description of main parameter as the table shown.
address tables are unicast addresses, The permanent static address is
Table 4-17 Main parameter
configured in static MAC address port table. You need to modify
corresponding entries when the port changes. The aging time of MAC
address is 300s, after port disconnected , the upper port operation
User Index
procedures clear all correspond port entries.
4.8 System Management
Visit Level
User Name
4.8.1 IP Address
IP address is a 32 bit length address connected on Internet equipment. IP
address consist of two parts: Network-Id and Host-Id.
On this page, you can check the IP address and etc for this device, just shown in
figure 4-15.
Description
Parameter
Input Password
Confirm
Password
User index indicates the group of users, There are three user
indexes in drop down table.
Administrator: view and set all configuration.
User: some functions.
The identification of visitors. The combination of alphabet and
Chinese character.
Visitor password, the combination of alphabet and Chinese
character.
P assword confirmed.
Instruction
Users enjoy the permission rights of all functions except for “power
configuration”,delete all logs ” , “ update software ” and “restore factory
setting”.
Figure 4-15 IP address
Caution
Caution
(1) We could set IP address range as 192.168.x.x,172.[16-31].x.x or
39
(1) If you forget your user name and password, please contact technical
support in order to get help.
(2) Set the same user name , only the top user / password could work.
10.x.x.x;
(3) Web supports up to one administrator and two ordinary users,
(2) Please fill in correct DNS address when using it for NTP and EMAIL.
administrators can not be deleted.
40
4.8.4 File Management
4.8.3 Log Information
The log function allows users to access system operation, When this function is
On [System management/ File management] page,You could check
enabled, corresponding events are recorded to the log:
configure document, software upgrade, restore factory setting and reboot
(1) System restart;
system as shown in the figure 4-18.
(2) Port Link Down/UP;
(3) Power supply status;
(4) login information;
(5) Boardcast storm;
(6) System action and operation record;
(7) NTP time synchronization information;
(8) Other system information.
On [System management/ Log information ]page, you could check the time
and type of event , as shown in the figure 4-17.
Figure 4-18 Document management
The main parameter descriptions are shown as the following table.
Table 4-19 Main parameter description
Parameter
Configuration
File
Figure 4-17 Log information
The received frame statistics and transmit frame statistics are shown as the
Table 4-18 Part of error package description
Parameter
Log Sever
Address
grade
Select configuration file you want to restore and restore all
configuration of switch (File format .cfg).
Restore Factory Recover all configuration except for IP address, user name
and password.
System Reboot Restart system and return to system status page.
Description
The server address receiving log information.
There are eight optional levels: error information,
Record lowest
Backup switch configuration (File format .cfg );
Software Update Select the software you want to upgrade.
Defaults
table .
Description
Caution
(1) Please keep the switch energized during the upgrade process and do
notification information to be logged, information in need of
not off the power.
quick reaction, serious information, information that can
(2) Please save configuration before rebooting, otherwise the unsaved
not be used in system, normal but important information,
configuration information will lose.
information in debug, warning information.
Download All
Information
Delete All
Information
41
Download all information(Format.cfg).
Deleted all information.
42
4.9 PoE Management
On PoE management page, you could turn on/off PoE function, set input
power , maximum overload, reservation power etc, as shown in figure 4-19.
Parameter
Power
provided
Description
Determined by built-in power supply module and can not
exceed maximum power supply.
Built-in power supply allows overload rate. Setting range
Overload limit
0%~10%, default 5%, if actual output power is overlarge, it will
cause built-in power supply exceeds the set value, the
system will power off ports with lower priority.
Reservation power can not be used for distribution, but can be
used for PD consumption caused by overload change, The
default is 15% of the total power. The larger this number, the
Reserved rate smaller the risk of system overload, So the usable power for
distribution and PD quantity become less; on the contrary,
the more the number of PD access, the greater risk of system
overload.
Figure 4-19 PoE management
Consumed
Caution
Actual output total power.
Means power that could be used for redistribution. surplus=
input - actual output - reservation. Please note that when insert
(1) Please do not modify the input power, if the setting value is more
a new PD equipment, the power will be distributed based on
than the actual power of the built-in power, there will be a risk of
overload burning. If the setting value is less than the actual power for
Remaining
the detected PD power level instead of the actual power of
inserted PD , for example : when surplus power is 20W, the
the built-in power supply, it can not be fully allocated out.
system still can not distribute power nor supply power if insert
(2) Each port of the product is to provide maximum output power of
power level of PD is 25.5W and the actual power only requires
30W, if user setting exceeds 30W, 30W is still the maximum power
10W.
output only.
Reserved
The information of main parameter description as the table shown.
Provided
Table 4-20 Main parameter description
Used for PD consumption with overload changes, It stems from
the set menu “input power rate * reserve power”.
T otal power for system setting, It stems from the set menu “input
power”.
There have three level of “low”, “middle”, “high” for port power
Priority
supply priority. when the system is overloaded, the power
supply of the port with low priority will be turned off firstly.
Power limit
43
Set the output power limit for single port., the port will power
off when actual output power exceeds limit.
On/Off
Power on the port POE function /power off the port POE
Setting
Sett port priority, maximum power consumption.
44
4.10 QoS Management
4.10.2 DSCP/TOS QoS
4.10.1 QoS setting
[QoS Setting/ DSCP/TOS QoS] Interface,can modify the setting [ DSCP/TOS
On the QoS management/QoS Settings page, you can modify / 802.1 P QoS
QoS],figure 4-21
function setting, as shown in figure 4-20.
Figure 4-20 802.1P QoS
The meaning of parameters in the page is shown in the following table.
Table 4-21 Main Parameter
Parameter
QoS Setting
on/Off
802.1P QoS
config
Discription
On/Off QoS function, Default is Off
Parameter
DSCP Scope
priority is 7,then to 6、5、4、3、2、1、0
As the default value, The absence of other priority value set
Priority for 0 queue to queue, 7 , 7 queue as the highest
priority queue
Description
DSCP/TOS QoS ON/OFF DSCP/TOS QoS , Default is Off
Traffic priority,802.1P define in 8 Priority, the highest
automatically enabled
Priority
The meaning of parameters in the page is shown in the following table
Table 4-22 Main Parameter Description
Iidentify scopes is 0、1、2、3、4、5、6、7,Total 8 ID,0
802.1P Scope
Figure 4-21 DSCP/TOS QoS
DSCP Priorty
TOS Identifies scope,Scope is 0-63
TOS Priority, priority for zero queue to queue, 7 7 queue for
priority
Configuration guide:
For example the id 0-16 is set to the highest queue。
Start using DSCP/TOS QoS configuration;
In DSCP ID scope Input 1-10,DSCP Priority Choose the seventh queue
priority;
Configuration guide:
Click Setting and save
Example: Set ting ID 6、7 to Lowest queue.
Turn on QoS setting & 802.1P QoS Setting;
End of operation.
802.1P ID scope Input 6-7,Priorty set line 0;
Click Settings, then save;
End of operation.
Instruction
When start using 802.1P &DSCP/TOS QoS at the same time,DSCP/TOS
QoS Priority First 。
Instruction
The arrangement of equipment use for the WRR queue scheduling,
priority mode for the relative priority.Equipment in the default setting
priority 0 and 1 is mapped to the first priority queue. Namely the lowest
priority queue.Priority 2 and 3 mapped to the second priority queue.4 and
5 priority priority mapping to the third queue.6 and 7 mapped to the highest
priority priority queue is the highest priority queue.
45
46
Environment protection
This product design is environmental friendly and the product should be stored,
used and dicarded in accordance with relevant national legal / regulatory
requirements.
47
Download PDF