Model:
KJP 33
Powered by PERKINS
Diesel Generator
Generating Rates
PRIME
STANDBY
Power
kVA
30
33
Power
kW
24
26
Current
(cos Phi=0,8) A
43
47
Standard Voltage
V
400/230
Revolution Per Minute
r.p.m.
1500
Rated at power factor
Cos Phi
0,8
Standard Features
Optional Equipments
4 Stroke, 1500 RPM, water cooled heavy duty diesel engine
Soundproof canopy
Protection system on manuel run
Automatic transfer switch
Flexible oil pipes and oil draining valve
Circuit breaker
Pre-heater
Trailer
Lubrication oil and anti-freeze
External fuel tank
4 Poles, synchrontype, single bearing, brushless alternator
Heating system for fuel tank
Batteries and cables
Oil heater
Electrostatic paint coated, steel, welded chassis
Fuel filling system ( Automatic / Manuel )
Fuel tank housed in the chassis.
Analog indicators
Industrial type silencer
1 Phase - 3 Phase switch plugs
Electronic battery charger
Alarm system for fuel level
Electrical wiring diagram
Remote control and monitoring
User manual and operating manual
Stand By Power : Supplying of emergency electrical power at variable load, in the event of normal utility power failure. This rating is
maximum power, no overload capability is available.
Prime Power : Supplying of electrical power at variable load for an unlimited number of hours in the event of normal utility power
failure. 10% over load capability is available.
KJP33ds-1
Update Date : 18-01-17 13:01
KÜRKÇÜOĞLU JENERATÖR SANAYİ VE TİC.A.Ş.
Sanayi Mah. Uran Sokak No:3 / 1 Pendik / İstanbul Tel.:+90 216 378 97 07 pbx - Fax: +90 216 378 97 06 - Web:www.kj.com.tr - info@kj.com.tr
Model:
KJP 33
Powered by PERKINS
Diesel Generator
Engine Specifications
Brand
PERKINS
Model
1103A-33G
(kWm / hp)
Engine Power Stand BY
(r.p.m.)
Revolution Per Minute
(L)
Total Displacement
Cylinders Orientation
1500
3.3
3 SINGLE LINE
(mm x mm)
Bore x Stroke
30,0/40,0
105 x 127
Compression Orientation
19,25:1
Governor Type
MECHANIC
Aspiration System
NATURAL
Injection
DIRECT
Cooling
WATER COOLED
Electrical System
(VDC)
12
Lub-Oil Capacity
(L)
7.9
Engine Coolant Capacity
(L)
10.2
Fuel Tank Capacity
(L)
71
(°C)
500
Maximum Exhaust Gas Flow
(m3/h)
5.7
Maximum Allowed Back Pressure
(kPa)
8
Maximum Exhaust Temperature
(m3/min)
53
Fuel Consumption 50 %
(L/h)
4
Fuel Consumption 75 %
(L/h)
5.6
Fuel Consumption 100 %
(L/h)
7.2
Cooling Air Flow
Replacable cylinder jacket
Dry type replacable oil filter
Heat-resistant radiator for 50 °C
Alternator Specifications
Output Voltage
Frequency
(V)
400/230
(Hz)
50
(±)
Stationary Voltage Regulation
1%
Short Circuit Current
> 300 %
Insulation
H
Protection
IP 23
(%)
Efficiency
Overloading
110 % FOR 1 HOUR
(cos Phi)
Power Factor
88,1
0.8
Total Harmonic Distortion Rate
THF < 2 %
Connection Type
STAR
Number Of Pole
4
Number Of Bearing
SINGLE
4 Poles, Self-Excitation and Self-Cooled, Brushless, Synchrontype alternator
Electronic type automatic voltage regulator (AVR)
Update Date : 18-01-17 13:01
KJP33ds-2
KÜRKÇÜOĞLU JENERATÖR SANAYİ VE TİC.A.Ş.
Sanayi Mah. Uran Sokak No:3 / 1 Pendik / İstanbul Tel.:+90 216 378 97 07 pbx - Fax: +90 216 378 97 06 - Web:www.kj.com.tr - info@kj.com.tr
Model:
KJP 33
Powered by PERKINS
Diesel Generator
Dimensions Without Canopy
Dimensions With Canopy
Dimensions and Weight
Dimensions and Weight
Length ( L )
mm
1650
Length ( L )
mm
2100
Height ( H )
mm
1500
Height ( H )
mm
1600
Width ( W )
mm
950
Width ( W )
mm
950
Wet weight
kg
685
Wet weight
kg
950
Fuel Tank Capacity
L
71
Fuel Tank Capacity
L
71
Control Panel Features
• Multiple automatic exerciser
• Contactor & MCB drive
• Weekly operation schedule
• 4 quadrant genset power counters
• Dual mutual standby with
equal aging of gensets
• Mains power counters
• 400 event logs, full snapshot
• All parameters front panel
editable
• Manual "speed fine adjust" on
selected ECUs
• 3 level configuration password
• Automatic fuel pump control
• 128x64 graphical LCD display
• Disable protections feature
• Downloadable language
• Excess power protection
• Waveform display of V & I
• Reverse power protection
• Harmonic analysis of V & I
• Overload IDMT protection
• Synchroscope & check synch
• Load shedding, dummy load
• Ready for central monitoring
Ethernet and GPRS
• Allows closed transfers
• Multiple load management
• Mobile genset support
• 16Amp MCB & GCB outputs
• Current unbalance protection
• Automatic GSM geo-location
• 8 configurable digital outputs
• Voltage unbalance protection
• GPS connectivity ( USB & RS232 )
• Outputs expandable to 40
• Fuel fiiling & fuel theft alarms
• Dynamic DNS support
• 4 configurable analog inputs
• Battery back-up real time clock
• Easy USB firmware upgrade
• Both CANBUS-J1939 & MPU
• Idle speed control
• IP65 rating with standard gasket
• 3 configurable service alarms
• Battery charge0 run enabled
• Multiple nominal conditions
• Combat mode support
• Diesel and gas genset
support
• 400Hz operation support
• Fuel fiiling counter
• Fuel consumption counter
• Modem & Ethernet diagnostics
• Configurable through USB,
RS-485, Ethernet and GPRS
• Free configuration program
• Allows SMS controls
Update Date : 18-01-17 13:01
KÜRKÇÜOĞLU JENERATÖR SANAYİ VE TİC.A.Ş.
KJP33ds-3