Spare Parts
&
Accessories
Reliable Storage Networking Solution Provider
2U Profile, 12- or 8-bay
Single-Controller
Major Markets and Uses
Fibre to SATA-II RAID Subsystem
Infortrend products are used in
disk-to-disk backup, server-attached
and network data storage and in major
industries such as medical imaging, security/CCTV, and digital media including
EonStor A12F/A08F-G2221
video-on-demand, stream editing and more.
Spare Parts
Description
Part Number
Fibre-to-SATA RAID controller module, 2 x FC-2G host channels, 8 x SATA-II drive channels.
IFT-82AF22GD08
Fibre-to-SATA RAID controller module, 2 x FC-2G host channels, 12 x SATA-II drive channels.
Drive tray, Type-III bezel and Type-II LED lightpipe
IFT-82AF22GD12
IFT-9273CDTray
Power supply module, EonStor 2U DDR-interface subsystems, 350W capacity
IFT-9272CPSU-0011
Intelligent cooling fan module for EonStor 2U DDR-interface subsystems
IFT-9272CFanModE
Right-side forearm handle for 2U subsystems
IFT-9272CHandR
Left-side forearm handle for 2U subsystems, LCD keypad panel
IFT-9272CHandLLCD
Accessories
Description
Part Number
Agilent Fibre Channel 2.125/1.0625 GBd small form factor pluggable optical transceiver, LC,
wave-length 850nm, multi-mode
IFT-9270CSFP2GA01
Optical FC cable, LC-LC, MM-62.6/125, duplex, LSZH, O.D.=1.8mmx2, 1 meter
IFT-9270CFCCab01
Optical FC cable, LC-LC, MM-62.6/125, duplex, LSZH, O.D.=1.8mmx2, 5 meters
IFT-9270CFCCab02
Optical FC cable, LC-LC, MM-62.6/125, duplex, LSZH, O.D.=1.8mmx2, 10 meters
IFT-9270CFCCab03
Battery cell pack, Li-ION battery cells
RS-232C serial cable, audio-jack-to-DB9
IFT-9273CBT-C
IFT-9270ASCab
*One included in the shipping package
Null modem, DB9-female-to-DB9-male, wires swapped *One included in the shipping package
Enhanced Slide rails assembly for 2U enclosures, 21"~28.5" rack depth
IFT-9011
Enhanced Slide rails assembly for 2U enclosures, 23"~36” rack depth
IFT-9272CEslide36
IFT-9272CEslide28
Infortrend
www.infortrend.com
Americas
Infortrend Corporation
3150 Coronado Dr., Unit C
Santa Clara, CA 95054, USA
Tel:+1-408-988-5088
Fax:+1-408-988-6288
sales@infortrend.com
tsd@infortrend.com
http://www.infortrend.com
Asia Pacific
Infortrend Technology, Inc.
8F, No. 102 Chung-Shan Rd., Sec. 3
Chung-Ho City, Taipei Hsien, Taiwan
Tel:+886-2-2226-0126
Fax:+886-2-2226-0020
sales@infortrend.com.tw
support@infortrend.com.tw
http://www.infortrend.com.tw
China
Infortrend Technology, Ltd.
Room 1210, West Wing, Tower One,
Junefield Plaza, No. 6 Xuanwumen Street,
Xuanwu District, Beijing, China. 100052
Tel:+86-10-63106168
Fax:+86-10-63106188
sales@infortrend.com.cn
support@infortrend.com.cn
http://www.infortrend.com.cn
Copyright c 2005 by Infortrend Technology, Inc. All rights reserved.
* Any information provided herein is without warranties of any kind and is subject to change by Infortrend without prior notice.
* Infortrend offers a 3-year limited warranty on subsystems and a 1-year warranty on battery backup units.
Japan
Infortrend Japan, Inc.
6F Okayasu Bldg., 1-7-14 Shibaura,
Minato-ku, Tokyo, 105-0023 Japan
TEL:+81-3-5730-6551
FAX:+81-3-5730-6552
sales@infortrend.co.jp
support@infortrend.co.jp
http://www.infortrend.co.jp
Europe
Infortrend Europe Ltd.
5 Elmwood, Crockford Lane
Chineham Business Park
Basingstoke, Hampshire
RG24 8WG, UK
Tel:+44-1256-70-77-00
Fax:+44-1256-70-78-89
sales@infortrend-europe.com
support@infortrend-europe.com
http://www.infortrend-europe.com
* Infortrend and the Infortrend logo are registered trademarks of Infortrend Technology, Inc.
* EonStor and RAIDWatch are registered trademarks of Infortrend Technology, Inc.
* All other names, brands, products, or services are trademarks or registered trademarks of their
respective owners.
July 2005
Designed using Infortrend's next-generation, custom ASIC266 as a dedicated XOR engine,
the EonStor A12F and A08F offers unmatched performance and ample margins for flexible
load-balancing and multi-pathing algorithms. Providing a twofold performance increase, the
dedicated ASIC architecture frees the PowerPC CPU of XOR computing load and features
extreme versatility for the subsystem's various data protection features with minimum
disturbance to host access.
Infortrend
www.infortrend.com
HIGHLIGHTS
Reliable Storage
Networking Solution Provider
The subsystem provides two FC-2G host
channels with 12 or 8 drive bays for SATA-II
disk drives in a smartly managed enclosure.
The subsystem combines massive storage
capacity with SATA-II benefits, such as high
performance and dedicated bandwidth, in a
safe environment where the highest level of
data availability is assured. High throughput
is available by segregating I/O traffic across
the separate PCI-X buses, while IOPS
performance is delivered through the internal
buffer on the XOR engine and CPU with the
help of intelligent firmware algorithms.
Infortrend's RAID functionality is unmatched
in the industry in terms of its wide variety of
array configuration, maintenance, and
monitoring capabilities. The Fibre-to-SATA
series provides IT professionals with versatile
options to meet their needs.
Highlights
. Two (2) FC-2G host channels; transfer rate up to
200MBps per channel
. RAID5 configuration end-to-end I/O performance
Sequential Read: 332MB/sec
Sequential Write: 263MB/sec
. Single RAID controller providing complete RAID
functionality
. Designed to use 3Gbps SATA-II disk drives;
backward compatible with SATA-I disk drives
. Modular, passive backplane, high redundancy
enclosure design
. High density 2U chassis providing up to 4.8TB of
storage capacity
. Optional, hot-swappable battery backup units
(BBU)
. Dual-speed cooling fans to reduce system noise
. DDR cache memory up to 2GB
. SATA NCQ support
. Ease of management through an LCD keypad panel,
RS-232C terminal, or an Ethernet link (TCP/IP) to a
PC running Java-based RAIDWatch R manager
. Real-time event notification by a variety of methods
. Hardware provider interface ready for third-party
management software that supports Windows
Server 2003 Virtual Disk Service (VDS)
Reliability
The subsystem supports a complete list of RAID
configuration levels in the forms of logical drives,
logical volumes and logical partitions. Multiple RAID
configurations can co-exist within one enclosure,
each with distinct write policy, stripe size, and
optimization modes. Hot rebuild and numerous
fault correction mechanisms ensure the highest
standard of RAID protection.
www.infortrend.com
Safe distribution of data is embodied in many ingenious
fault-preventive designs. From memory ECC, writeverify, parity regeneration, parity update tracking,
Media Scan, to battery backup protection, your data is
warded against factors that might cause data
inconsistencies. For example, the subsystem is capable
of managing storage arrays with fault containment
algorithms. If a critical component fails, e.g., a battery
module, the subsystem automatically disables its writeback caching and assumes the conservative writethrough mode. Algorithms like this guarantees that
data is reliably managed and all risk factors are always
carefully checked.
These adaptive designs assure sufficient throughput for
a wide range of applications running on Windows
2000/2003/XP, Linux, or Unix-based servers. Ideal
applications include Disk-to-Disk backup, data
archiving, business network, storage consolidation and
others.
Availability
The A12F and A08F subsystems are equipped with fieldhardened technologies that ensure data protection and
a simple, centralized management. The subsystems are
managed by firmware developed with sophisticated
RAID technologies and redundant component designs.
Incorporating various data protection algorithms and
featuring RAID levels 0, 1(0+1), 3, 5, 10, 30, and 50,
the subsystem actually offers capabilities only seen in
enterprise-class solutions.
To ensure a high level of system availability, critical
components such as disk drives, power supplies, and
cooling fans, are all redundant and hot-swappable.
Modules are integrated with the main signal path PCB
via board-to-board or interface- specific connectors to
eliminate points of failure. Assisted by GUI
management software, the operating status of all
components can be constantly monitored through a local
or remote console.
Availability
All critical modules are housed in their own removable
canister, including hard disk drives, power supplies,
battery modules, and cooling fans. In the event of
component failure, each can be replaced within
seconds. Spring screws, securing latches, and key-locks
all help provide easier access to the modules.
A variety of configuration and monitoring methods are
available, either locally via the LCD keypad panel and
the text-mode RS-232C terminal utility, or remotely
through the Java-based GUI manager. All fault
conditions, including module failure and abnormal
voltage and temperature readings, are instantly
reported. A system administrator can choose to be
notified via LAN broadcast, SNMP traps, email, fax, SMS,
ICQ, and MSN messenger when he is away from the
installation site. Even the notification utility can be
installed redundantly on two different machines to avoid
the chance of blind time due to a simple component
failure.
SPECIFICATIONS
www.infortrend.com
Reliable Storage Networking Solution Provider
Infortrend Smart Technologies
more time to prepare a rebuild, and help minimize
performance impact. DrvSmart functions include Media
Scan & Task Scheduler, hot-spare, drive roaming, SMART
and manual cloning options, etc.
Derived from more than ten years of experience in
RAID storage design, our firmware features extremely
compact protocol and rich varieties of algorithms to
deal with the stringent requirements of storage
applications. The technologies are smart for I/O
processing, drive handling, and system management.
SysSmart
IOSmart
The IOSmart technologies consist of specific functions
and configuration options that control various I/O
characteristics in order to meet the rapidly increasing
requirements of today's applications. These functions
include the adaptable stripe size, Adaptive write policy,
optimizations modes, Guaranteed Latency I/O, and the
automatically adjusted multi-threaded, predictive readahead, sorted, or group writes.
SysSmart combines enclosure monitoring and firmware
management capabilities in order to minimize the
chance of down time caused by hardware failures. With
SysSmart, Infortrend's subsystems are smartly
managed and guarded against extreme operating
conditions.
SysSmart functions include the event-triggered, Auto
data protection mechanisms and the various
monitoring utilities and monitoring approaches
combined with the powerful RAIDWatch manager.
DrvSmart
DrvSmart is comprised of fault-preventive algorithms
that ensure data integrity when conditions related to
hard drive imperfections occur. DrvSmart mechanisms
correct minor defects, increase reaction time, allow
Specifications
Subsystem Characteristics
. 400MHz CPU, 256KB L2 cache
. ASIC266 RAID engine
. DDR cache memory
. FC-2G host channels
. LCD keypad panel
. COM ports
. 10/100BaseT Ethernet port
. Diagnostic LEDs on all FRUs
Drive Interface
. Number of disk trays
. Serial SATA-I/II drive supported
Host Interface
. SFP ports to optical fiber
. Transfer rate
. Tag command queuing
. Multiple target IDs
256MB
2
1
1
1
Yes
12/8
Yes
2
200MBps
RAID Configurations
. RAID levels 0, 1(0+1), 3, 5, 10, 30, 50, JBOD
. Max. 16 logical drives
. Max. 128 LUNs
. Multiple array configurations
. Automatic background rebuild
. Infortrend Smart Technologies
www.infortrend.com
High Availability
. Redundant, hot-swappable FRUs
. Subsystem self-diagnostics
. Backup backup unit
. Hot-spare drives
Management
. RAIDWatch GUI software
. Terminal via RS-232C
. Telnet over Ethernet
. LCD keypad panel
. Event notification methods
Email
Fax
LAN broadcast
SNMP traps
Cell phone message
Instant messengers
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
SMS
MSN/ICQ
OS Support
. Microsoft Windows NT
. Microsoft Windows 2000 Server
. Microsoft Windows 2003 Server
. Sun Solaris ver. 8/9
. RedHat Linux ver. 8/9, enterprise ver. 3
. SuSE Linux ver. 8/9
Requirements
. AC Input:
100VAC at 6A; 240VAC at 3A
with PFC (auto-switching)
. DC Output:
12V-25A; 5V-25A; 3.3V-20A
. Relative Humidity:
5% to 95% non-condensing
. Operating Temperature:
0 to 40OC
Dimensions
2U, 19-inch rackmount chassis
. Without handles:
446(W) x 88(H) x 490(D) mm
(17.6" x 3.5" x 19.3" )
. With handles:
482(W) x 88(H) x 505(D) mm
(19" x 3.5" x 19.9" )
HIGHLIGHTS
Reliable Storage
Networking Solution Provider
The subsystem provides two FC-2G host
channels with 12 or 8 drive bays for SATA-II
disk drives in a smartly managed enclosure.
The subsystem combines massive storage
capacity with SATA-II benefits, such as high
performance and dedicated bandwidth, in a
safe environment where the highest level of
data availability is assured. High throughput
is available by segregating I/O traffic across
the separate PCI-X buses, while IOPS
performance is delivered through the internal
buffer on the XOR engine and CPU with the
help of intelligent firmware algorithms.
Infortrend's RAID functionality is unmatched
in the industry in terms of its wide variety of
array configuration, maintenance, and
monitoring capabilities. The Fibre-to-SATA
series provides IT professionals with versatile
options to meet their needs.
Highlights
. Two (2) FC-2G host channels; transfer rate up to
200MBps per channel
. RAID5 configuration end-to-end I/O performance
Sequential Read: 332MB/sec
Sequential Write: 263MB/sec
. Single RAID controller providing complete RAID
functionality
. Designed to use 3Gbps SATA-II disk drives;
backward compatible with SATA-I disk drives
. Modular, passive backplane, high redundancy
enclosure design
. High density 2U chassis providing up to 4.8TB of
storage capacity
. Optional, hot-swappable battery backup units
(BBU)
. Dual-speed cooling fans to reduce system noise
. DDR cache memory up to 2GB
. SATA NCQ support
. Ease of management through an LCD keypad panel,
RS-232C terminal, or an Ethernet link (TCP/IP) to a
PC running Java-based RAIDWatch R manager
. Real-time event notification by a variety of methods
. Hardware provider interface ready for third-party
management software that supports Windows
Server 2003 Virtual Disk Service (VDS)
Reliability
The subsystem supports a complete list of RAID
configuration levels in the forms of logical drives,
logical volumes and logical partitions. Multiple RAID
configurations can co-exist within one enclosure,
each with distinct write policy, stripe size, and
optimization modes. Hot rebuild and numerous
fault correction mechanisms ensure the highest
standard of RAID protection.
www.infortrend.com
Safe distribution of data is embodied in many ingenious
fault-preventive designs. From memory ECC, writeverify, parity regeneration, parity update tracking,
Media Scan, to battery backup protection, your data is
warded against factors that might cause data
inconsistencies. For example, the subsystem is capable
of managing storage arrays with fault containment
algorithms. If a critical component fails, e.g., a battery
module, the subsystem automatically disables its writeback caching and assumes the conservative writethrough mode. Algorithms like this guarantees that
data is reliably managed and all risk factors are always
carefully checked.
These adaptive designs assure sufficient throughput for
a wide range of applications running on Windows
2000/2003/XP, Linux, or Unix-based servers. Ideal
applications include Disk-to-Disk backup, data
archiving, business network, storage consolidation and
others.
Availability
The A12F and A08F subsystems are equipped with fieldhardened technologies that ensure data protection and
a simple, centralized management. The subsystems are
managed by firmware developed with sophisticated
RAID technologies and redundant component designs.
Incorporating various data protection algorithms and
featuring RAID levels 0, 1(0+1), 3, 5, 10, 30, and 50,
the subsystem actually offers capabilities only seen in
enterprise-class solutions.
To ensure a high level of system availability, critical
components such as disk drives, power supplies, and
cooling fans, are all redundant and hot-swappable.
Modules are integrated with the main signal path PCB
via board-to-board or interface- specific connectors to
eliminate points of failure. Assisted by GUI
management software, the operating status of all
components can be constantly monitored through a local
or remote console.
Availability
All critical modules are housed in their own removable
canister, including hard disk drives, power supplies,
battery modules, and cooling fans. In the event of
component failure, each can be replaced within
seconds. Spring screws, securing latches, and key-locks
all help provide easier access to the modules.
A variety of configuration and monitoring methods are
available, either locally via the LCD keypad panel and
the text-mode RS-232C terminal utility, or remotely
through the Java-based GUI manager. All fault
conditions, including module failure and abnormal
voltage and temperature readings, are instantly
reported. A system administrator can choose to be
notified via LAN broadcast, SNMP traps, email, fax, SMS,
ICQ, and MSN messenger when he is away from the
installation site. Even the notification utility can be
installed redundantly on two different machines to avoid
the chance of blind time due to a simple component
failure.
SPECIFICATIONS
www.infortrend.com
Reliable Storage Networking Solution Provider
Infortrend Smart Technologies
more time to prepare a rebuild, and help minimize
performance impact. DrvSmart functions include Media
Scan & Task Scheduler, hot-spare, drive roaming, SMART
and manual cloning options, etc.
Derived from more than ten years of experience in
RAID storage design, our firmware features extremely
compact protocol and rich varieties of algorithms to
deal with the stringent requirements of storage
applications. The technologies are smart for I/O
processing, drive handling, and system management.
SysSmart
IOSmart
The IOSmart technologies consist of specific functions
and configuration options that control various I/O
characteristics in order to meet the rapidly increasing
requirements of today's applications. These functions
include the adaptable stripe size, Adaptive write policy,
optimizations modes, Guaranteed Latency I/O, and the
automatically adjusted multi-threaded, predictive readahead, sorted, or group writes.
SysSmart combines enclosure monitoring and firmware
management capabilities in order to minimize the
chance of down time caused by hardware failures. With
SysSmart, Infortrend's subsystems are smartly
managed and guarded against extreme operating
conditions.
SysSmart functions include the event-triggered, Auto
data protection mechanisms and the various
monitoring utilities and monitoring approaches
combined with the powerful RAIDWatch manager.
DrvSmart
DrvSmart is comprised of fault-preventive algorithms
that ensure data integrity when conditions related to
hard drive imperfections occur. DrvSmart mechanisms
correct minor defects, increase reaction time, allow
Specifications
Subsystem Characteristics
. 400MHz CPU, 256KB L2 cache
. ASIC266 RAID engine
. DDR cache memory
. FC-2G host channels
. LCD keypad panel
. COM ports
. 10/100BaseT Ethernet port
. Diagnostic LEDs on all FRUs
Drive Interface
. Number of disk trays
. Serial SATA-I/II drive supported
Host Interface
. SFP ports to optical fiber
. Transfer rate
. Tag command queuing
. Multiple target IDs
256MB
2
1
1
1
Yes
12/8
Yes
2
200MBps
RAID Configurations
. RAID levels 0, 1(0+1), 3, 5, 10, 30, 50, JBOD
. Max. 16 logical drives
. Max. 128 LUNs
. Multiple array configurations
. Automatic background rebuild
. Infortrend Smart Technologies
www.infortrend.com
High Availability
. Redundant, hot-swappable FRUs
. Subsystem self-diagnostics
. Backup backup unit
. Hot-spare drives
Management
. RAIDWatch GUI software
. Terminal via RS-232C
. Telnet over Ethernet
. LCD keypad panel
. Event notification methods
Email
Fax
LAN broadcast
SNMP traps
Cell phone message
Instant messengers
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
SMS
MSN/ICQ
OS Support
. Microsoft Windows NT
. Microsoft Windows 2000 Server
. Microsoft Windows 2003 Server
. Sun Solaris ver. 8/9
. RedHat Linux ver. 8/9, enterprise ver. 3
. SuSE Linux ver. 8/9
Requirements
. AC Input:
100VAC at 6A; 240VAC at 3A
with PFC (auto-switching)
. DC Output:
12V-25A; 5V-25A; 3.3V-20A
. Relative Humidity:
5% to 95% non-condensing
. Operating Temperature:
0 to 40OC
Dimensions
2U, 19-inch rackmount chassis
. Without handles:
446(W) x 88(H) x 490(D) mm
(17.6" x 3.5" x 19.3" )
. With handles:
482(W) x 88(H) x 505(D) mm
(19" x 3.5" x 19.9" )
Spare Parts
&
Accessories
Reliable Storage Networking Solution Provider
2U Profile, 12- or 8-bay
Single-Controller
Major Markets and Uses
Fibre to SATA-II RAID Subsystem
Infortrend products are used in
disk-to-disk backup, server-attached
and network data storage and in major
industries such as medical imaging, security/CCTV, and digital media including
EonStor A12F/A08F-G2221
video-on-demand, stream editing and more.
Spare Parts
Description
Part Number
Fibre-to-SATA RAID controller module, 2 x FC-2G host channels, 8 x SATA-II drive channels.
IFT-82AF22GD08
Fibre-to-SATA RAID controller module, 2 x FC-2G host channels, 12 x SATA-II drive channels.
Drive tray, Type-III bezel and Type-II LED lightpipe
IFT-82AF22GD12
IFT-9273CDTray
Power supply module, EonStor 2U DDR-interface subsystems, 350W capacity
IFT-9272CPSU-0011
Intelligent cooling fan module for EonStor 2U DDR-interface subsystems
IFT-9272CFanModE
Right-side forearm handle for 2U subsystems
IFT-9272CHandR
Left-side forearm handle for 2U subsystems, LCD keypad panel
IFT-9272CHandLLCD
Accessories
Description
Part Number
Agilent Fibre Channel 2.125/1.0625 GBd small form factor pluggable optical transceiver, LC,
wave-length 850nm, multi-mode
IFT-9270CSFP2GA01
Optical FC cable, LC-LC, MM-62.6/125, duplex, LSZH, O.D.=1.8mmx2, 1 meter
IFT-9270CFCCab01
Optical FC cable, LC-LC, MM-62.6/125, duplex, LSZH, O.D.=1.8mmx2, 5 meters
IFT-9270CFCCab02
Optical FC cable, LC-LC, MM-62.6/125, duplex, LSZH, O.D.=1.8mmx2, 10 meters
IFT-9270CFCCab03
Battery cell pack, Li-ION battery cells
RS-232C serial cable, audio-jack-to-DB9
IFT-9273CBT-C
IFT-9270ASCab
*One included in the shipping package
Null modem, DB9-female-to-DB9-male, wires swapped *One included in the shipping package
Enhanced Slide rails assembly for 2U enclosures, 21"~28.5" rack depth
IFT-9011
Enhanced Slide rails assembly for 2U enclosures, 23"~36” rack depth
IFT-9272CEslide36
IFT-9272CEslide28
Infortrend
www.infortrend.com
Americas
Infortrend Corporation
3150 Coronado Dr., Unit C
Santa Clara, CA 95054, USA
Tel:+1-408-988-5088
Fax:+1-408-988-6288
sales@infortrend.com
tsd@infortrend.com
http://www.infortrend.com
Asia Pacific
Infortrend Technology, Inc.
8F, No. 102 Chung-Shan Rd., Sec. 3
Chung-Ho City, Taipei Hsien, Taiwan
Tel:+886-2-2226-0126
Fax:+886-2-2226-0020
sales@infortrend.com.tw
support@infortrend.com.tw
http://www.infortrend.com.tw
China
Infortrend Technology, Ltd.
Room 1210, West Wing, Tower One,
Junefield Plaza, No. 6 Xuanwumen Street,
Xuanwu District, Beijing, China. 100052
Tel:+86-10-63106168
Fax:+86-10-63106188
sales@infortrend.com.cn
support@infortrend.com.cn
http://www.infortrend.com.cn
Copyright c 2005 by Infortrend Technology, Inc. All rights reserved.
* Any information provided herein is without warranties of any kind and is subject to change by Infortrend without prior notice.
* Infortrend offers a 3-year limited warranty on subsystems and a 1-year warranty on battery backup units.
Japan
Infortrend Japan, Inc.
6F Okayasu Bldg., 1-7-14 Shibaura,
Minato-ku, Tokyo, 105-0023 Japan
TEL:+81-3-5730-6551
FAX:+81-3-5730-6552
sales@infortrend.co.jp
support@infortrend.co.jp
http://www.infortrend.co.jp
Europe
Infortrend Europe Ltd.
5 Elmwood, Crockford Lane
Chineham Business Park
Basingstoke, Hampshire
RG24 8WG, UK
Tel:+44-1256-70-77-00
Fax:+44-1256-70-78-89
sales@infortrend-europe.com
support@infortrend-europe.com
http://www.infortrend-europe.com
* Infortrend and the Infortrend logo are registered trademarks of Infortrend Technology, Inc.
* EonStor and RAIDWatch are registered trademarks of Infortrend Technology, Inc.
* All other names, brands, products, or services are trademarks or registered trademarks of their
respective owners.
July 2005
Designed using Infortrend's next-generation, custom ASIC266 as a dedicated XOR engine,
the EonStor A12F and A08F offers unmatched performance and ample margins for flexible
load-balancing and multi-pathing algorithms. Providing a twofold performance increase, the
dedicated ASIC architecture frees the PowerPC CPU of XOR computing load and features
extreme versatility for the subsystem's various data protection features with minimum
disturbance to host access.
Infortrend
www.infortrend.com
Download PDF
Similar pages