New R410A lineup - Mitsubishi Electric VN

PRODUCT LINE -UP
Inverter R410a
Ceilingcassette
(PLY SERIES)
18,000 BTU/h
24,000 BTU/h
30,000 BTU/h
PLY-SP18BA
PLY-SP24BA
PLY-SP30BA
PCY-SP18KA
PCY-SP24KA
PCY-SP30KA
PEY-SP18JA
PEY-SP24JA
PEY-SP30JA
SUY-SA18VA
SUY-SA24VA
SUY-SA30VA
Ceilingsuspended
(PCY SERIES)
Ceilingconcealed
(PEY SERIES)
Outdoor Unit
Inverter Series
36,000 BTU/h
42,000 BTU/h
48,000 BTU/h
Remote Controller
02-03
Contents
P. 07-09
PLY-SP36BA
PLY-SP42BA
PLY-SP48BA
optional
optional
PCY-SP36KA
PCY-SP42KA
P. 10
PCY-SP48KA
optional
optional
PEY-SP36JA
PEY-SP42JA
PEY-SP48JA
optional
SUY-SA36VA
PUY-SP42V/YKA
PUY-SP36YKA
PUY-SP48V/YKA
P. 11
INVERTER TECHNOLOGIES
Mitsubishi Electric inverters ensure superior performance, including the optimum control of operation frequency. As a result,
optimum power is applied in all heating/cooling ranges and maximum comfort is achieved while consuming minimal energy.
Fast, comfortable operation and amazingly low running cost — That’s the Mitsubishi Electric promise.
INVERTERS – HOW THEY WORK
Inverters electronically control the electrical voltage, current and frequency of electrical devices such as the compressor motor in an air
conditioner. They receive information from sensors monitoring operating conditions and adjust the rotation speed of the compressor, which
directly regulates air conditioner output. Optimum control of operation frequency results in eliminating the consumption of excessive electricity
and providing the most comfortable room environment.
ECONOMIC OPERATION
Impressively low operating cost is a key advantage of inverter-equipped air conditioners. We have combined advanced inverter technologies
with cutting- edge electronic and mechanical technologies to achieve a synergistic effect that enables improvements in heating/cooling
performance efficiency. As a result, better performance and lower energy consumption are achieved.
TRUE COMFORT
Below is a simple comparison of air conditioner operation control with and without an inverter.
■ Inverter operation comparison
Non-inverter air conditioner
On/Off operation of compressor
keeps room temperature
Inverter air conditioner
ON
OFF
ON
getting too hot
Compressor operation
Change in room
temperature
OFF
ON
Preset
temperature
Preset
temperature
Change in room
temperature
Full power
Optimum control of frequency
keeps preset room temperature
Minimum power
consumption
Constant room temperature
getting too cool
Time
Compressor operation
Time
The compressors of air conditioners without an inverter start and stop repeatedly in order to maintain the preset room temperature.
This repetitive on/off operation uses excessive electricity and compromises room comfort. The compressors of air conditioners
equipped with an inverter run continuously; the inverter quickly optimizing the operating frequency according to changes in room
temperature. This ensures energy-efficient operation and a more comfortable room.
Point 1
Quick & Powerful
Increasing the compressor motor speed by controlling the operation
frequency ensures powerful output at start-up, and brings the room
temperature to the comfort zone faster than units not equipped with an
inverter. Hot rooms are cooled, and cold rooms are heated, faster and
more efficiently.
Point 2
Room Temperature Maintained
The compressor motor operating frequency and the change in room
temperature are monitored to calculate the most efficient waveform to
maintain the room temperature in the comfort zone. This eliminates the
large temperature swings common with non-inverter systems and
guarantees a pleasant, comfortable environment.
Inverter Series
R410A refrigerant
04-05
Montreal Protocol
As scientific evidence points to man-made chemicals for the
damage caused to the ozone layer, we only use chlorine-free
refrigerants that are safe and rated zero ozone depletion
potential (ODP). Accordingly, our systems require less
energy to run and have significantly lower indirect global
warming potential. In short, we produce the most efficient
equipment possible, while helping to protect the environment.
Montreal Protocol regulates HCFCs
HCFC consumption in Article 5 countries will be regulated
from 2013.
100% Based on consumption in 2009 and 2010 of 100%.
90%
The Montreal Protocol calls for the complete abolishment of
HCFC refrigerant consumption in Article 5 countries (such as
R22) by the year 2030.
Mitsubishi Electric
has introduced HFC
refrigerants to meet
the target.
65%
Mitsubishi Electric is committed to shifting
over to HFC models from HCFC models.
32.5%
Complete
phase-out
2.5% (for service)
2013 2015
2020
2025
HCFC regulation starts
■ High energy efficiency
3.5
3.0
2.5
EER (W/W)
3.06
3.19
2.99
3.38
2.81
2.32
2.0
1.5
1.0
0.5
0
PLY-SP18BA
SUY-SA18VA
PLY-SP24BA
SUY-SA24VA
PLY-SP30BA
SUY-SA30VA
PLY-SP36BA
SUY-SA36VA
PLY-SP42BA
PUY-SP42VKA
PLY-SP48BA
PUY-SP48VKA
2030
2035
2040
CONTROL
TECHNOLOGIES
User-friendly Deluxe Remote Controller with Excellent
Operability and Visibility
PAR-31MAA (Optional)
Full-dot Liquid-crystal Display Adopted
Easy-to-Read & Easy-to-Use
Easier to read thanks to use of a full-dot liquid-crystal display with
backlight, and easier to use owing to the adoption of a menu format
that enabled the number of operating buttons to be reduced.
Multi-language Display
PAR-31MAA
Display Example [Operation Mode]
Control panel operation in eight
different languages
MultiIanguage
Full-dot LCD
[English]
Choose the desired language from
among the following.
[Spanish]
[Italian]
[German]
[Russian]
[French]
[Portuguese] [Swedish]
Energy-efficient Control
Operation Control Functions
Prevents wasteful operation by
automatically returning to the preset
temperature after specified operating time
Auto-return
After adjusting the initial temperature on a hot day, it is easy to forget to return the
temperature setting to its original value. The Auto-return function automatically
resets the temperature back to the original setting after a specified period of time,
thereby preventing overcooling. The Auto-return activation time can be set in
10-minute units, in a range between 30 and 120 minutes.
*Auto-return cannot be used when Temperature Range Restriction is in use.
Temperature Range Restriction
prevents overcooling
School
Public hall
Computer server facility
The Weekly Timer enables the setting of operation start and stop times and adjusting
the temperature as standard features. Up to 8 patterns per day can be set, providing
operation that matches the varying conditions of each period, such as the number of
customers in the store.*Weekly Timer cannot be used when On/Off Timer is in use.
Preparation
1
Busy
hours
Temperature setting (°C)
Set to lower temperature
30(˚C)
30(˚C)
*Joint research conducted with Japan Facility Solutions, Inc.
(Setting example of minimum temp. at 25°C)
Possible temperature range setting
25(˚C)
Office
Set up to 8 patterns per day including
temperature control
26
*In-house calculations
Cooling/Dry
Recommended for
Setting Example (restaurant in summer time)
Using a temperature that is 1°C higher for cooling results in a 10% reduction in
power consumption.* Temperature Range Restriction limits the maximum and
minimum temperature settings, contributing to the prevention of overcooling.
19(˚C)
In addition to operation start/stop, the operation mode, temperature setting and airflow direction can be locked. Unwanted adjustment of temperature settings is prevented and an appropriate temperature is constantly maintained, leading to energy
savings. This feature is also useful in preventing erroneous operation or tampering.
Weekly
Timer
This function monitors the room temperature and automatically activates the
cooling mode when the temperature rises above the preset maximum temperature setting.
Temperature
Range
Restriction
Fixed temperature setting promotes
energy savings
Hospital
Keep desired room temperatures
automatically
Night
Setback
Operation
Lock
Off-peak Set to higher temperature
hours
7
25
Opening
time
2
24
4
5
3
Dinner time
8-pattern setting
22
0
Closing time
6
Lunch time
23
8
10
12
14
16
18
20
22
24 (Time)
Lower temperature limit
To prevent excessive cooling
Lower temperatures cannot
be selected
Recommended for
Auto-off
Timer
Office
Restaurant
Turns cooling off
automatically after preset time
elapses
When using Auto-off Timer, even if one forgets to turn off the unit, operation stops
automatically after the preset time elapses, thereby preventing wasteful operation. Auto-off Timer can be set in 10-minute units, in a range between 30 minutes
and 4 hours. Eliminates all anxiety about forgetting to turn off the unit.
Recommended for
Meeting room
Changing room
Automatic
Grille Lowering
(4-way ceiling cassette)
Easily raise/lower panels using
the remote controller
(PLY-SP42/48BA)
An automatic panels lowering function is available as an option. The panels can
be lowered/raised using a button on the wired remote controller. Filter cleaning
can be performed easily.
06-07
Inverter Series
Advanced MA Remote Controller –
A Progressive Step in the Evolution of Air Conditioning Control
PAR-21MAA
Dot Liquid-crystal Display Adopted
Easy-to-Read/Easy-to-Use
The adoption of dot liquid-crystal display (LCD) technology and a
large display screen for the control panel optimise visibility. Operation and control status are easily read at a glance.
Multi-language Display
PAR-21MAA
Display Example [Operation Mode]
Control panel operation in eight
different languages
MultiIanguage
Dot LCD
Choose the desired language from among the
following.
[English]
[French]
[Spanish]
[Italian]
[German]
[Russian]
[Chinese]
[Japanese]
Energy-efficient Control
Operation Control Functions
Temperature
Range
Restriction
Weekly
Timer
Air conditioner operation restricted
to within a specified operating range
Control temperature on a weekly basis
Temperature settings and On/Off control can be managed over a period of one
week using the Weekly Timer. Up to eight setting patterns per calendar day are
possible.
Set the upper and lower limits for the temperature range during operation.
Excessive cooling is prevented, leading to increased energy savings.
Cooling/Dry
(Setting example of minimum temp. at 25°C)
19(˚C)
30(˚C)
Setting Example (restaurant in summer time)
Possible temperature range setting
26
30(˚C)
Lower temperature limit
To prevent excessive cooling
Lower temperatures cannot
be selected
Recommended for
Auto-off
Timer
Office
Restaurant
Automatically turns off
air conditioner
Set the time for the air conditioner to turn off automatically. The timer can be set
in the range from 30 minutes up to 4 hours in 30-minute intervals.
The “Simple Timer”— starts/stops in units of 1 hour in a 72-hour period — is set at
the time of shipment from the factory. It can be changed to the “Auto-off Timer”
function using the remote controller.
Recommended for
Operation
Lock
Meeting room
Changing room
Prevent operation settings
from being changed
Units can be set so that the operation mode cannot be changed. When “Operation Lock” is activated, new temperature setting commands are not accepted,
thereby ensuring that the unit runs in the specified (locked in) temperature range.
This promotes energy savings and prevents erroneous/ mischievous operation.
Only the administrator can change settings when using the Operation Lock mode.
Recommended for
Office
Hospital
School
Public hall
Computer server facility
Temperature setting (°C)
25(˚C)
Introduced in response to
market demand
Busy
hours
Set to lower temperature
Off-peak
hours
Set to higher temperature
25
6
Opening time
24
3
1
2
23
Closing time
5
Lunch time
4
Dinner time
7-pattern setting
22
0
7
10
12
14
16
18
(Results of cooperative study with Japan Facility Solutions, Inc.)
20
22
24 (Time)
SYSTEM CONTROL
Versatile system control can be realised using optional parts, relay circuits, control panels, etc.
MAJOR SYSTEM CONTROLS
System Examples
Indoor Unit
Outdoor Unit
PLY, PCY, PEY Series indoor unit
SUY Series outdoor unit
PUY Series outdoor unit
Indoor unit
PAR-31MAA Control
PAR-21MAA Control
PAR-31MAA
PAR-21MAA control
Outdoor unit
Details
Standard equipment (for indoor units compatible with wired remote controllers)
Major Optional Parts
Required
• PAR-31MAA (wired remote controller)
• PAR-21MAA (wired remote controller)
Indoor unit
Indoor unit
Indoor unit
Indoor unit
MAC-333IF-E
System Group Control
Outdoor unit
Outdoor unit
PAR-31MAA
PAR-21MAA
Outdoor unit
Details
• One remote controller can simultaneously control multiple air conditioners with the same settings.
• One remote controller can control up to 16 refrigerant systems.
• Up to two remote controllers can be connected.
Major Optional Parts
Required
• MAC-333IF-E (interface)
• PAR-31MAA (wired remote controller)
• PAR-21MAA (wired remote controller)
Outdoor
unit
Outdoor
unit
Indoor unit
Indoor unit
• PAR-31MAA (wired remote controller)
• PAR-21MAA (wired remote controller)
PAC-SC51KUA
power supply kit
Indoor unit
City Multi
indoor unit
M-NET Connections
PAR-31MAA
PAR-21MAA
PAR-31MAA
PAR-21MAA
MAC-333IF-E
PAR-31MAA
PAR-21MAA
Outdoor unit
MELANS
system controller
(AE-200E)
PAC-SC51KUA
power supply unit
PAR-31MAA
PAR-21MAA
Outdoor unit
MELANS
system controller
(AE-200E)
Details
• Group of air conditioners can be controlled by MELANS system controller (M-NET).
Major Optional Parts
Required
• MAC-333IF-E (interface)
• MELANS system controller
• PAC-SC51KUA (power supply unit)
• PAC-SF83MA-E (M-NET converter)
• MELANS system controller
• PAC-SC51KUA (power supply unit)
Indoor unit
PAR-31MAA
PAR-21MAA
Outdoor unit
M-NET adapter
PAC-SF83MA-E
Inverter Series
08-09
VARIATIONS FOR INDOOR UNITS (For SUY & PUY Series)
System Examples
Wired remote controller
A
2-remote Controller
Control
PAR-SL97A-E
With two remote controllers,
control can be performed
locally and remotely from two
locations.
PAR-31MAA
PAR-21MAA
Operation Control by
Level Signal
Air conditioner can be
started/stopped remotely.
In addition, On/Off operation by
local remote controller can be
prohibited/permitted.
PAR-31MAA
PAR-21MAA
* When using wired and
wireless remote controllers
* Set "Main" and "Sub"
remote controllers.
(Example of 1 : 1 system)
B
Wireless remote controller
Remote
control
panel
Relay box
(to be purchased locally)
Adapter
for remote
On/Off
Adapter
for remote
On/Off
(Example of 1 : 1 system x 2)
Remote
control
panel
PAR-SL97A-E
(Example of 1 : 1 system x 2)
Relay box
(to be purchased locally)
C
Operation Control by
Pulse Signal
Connector
cable for
remote
display
Remote
control
panel
Wired remote
controller
(Example of 1 : 1 system x 2)
Remote operation adapter/
Connector cable for remote
display + Relay box
D
Remote
display
panel
Connector
cable for
remote
display
Remote
control
panel
PAR-SL97A-E
Remote operation adapter/
Connector cable for remote
display + Relay box
PAR-SL97A-E
PAR-31MAA /PAC-YT52CRA
E
Timer Operation
Allows on/off operation with timer
*For control by an external timer, refer to
B Operation Control by Level Signal.
PAR-31MAA
(Example of 1 : 1 system)
• Wired remote controller
PAR-31MAA /PAR-21MAA
• Wireless remote controller
PAR-SL97A-E for PEY
• Wireless remote controller kit
for PCY PAR-SL94B-E
• Operation other than On/Off
(e.g., adjustment of
temperature, fan speed and
airflow) can be performed
even when remote controller
operation is prohibited.
• Timer control is possible with
an external timer.
• Adapter for remote On/Off
PAC-SE55RA-E
• Relay box
(to be purchased locally)
• Remote control panel
(to be purchased locally)
• The pulse signal can be turned
on/off.
• Operation/emergency signal
can be received at a remote
location.
• Connector cable for remote
display
PAC-SA88HA-E/PAC-725AD
(10 pcs. x PAC-SA88HA-E)
• Relay box
(to be purchased locally)
• Remote control panel
(to be purchased locally)
(Example of 1 : 1 system x 2)
Remote
display
panel
(Example of 1 : 1 system)
• Up to two remote controllers
can be connected to one
group.
• Both wired and wireless
remote controllers can be
used in combination.
Relay box
(to be purchased locally)
Remote Display of
Operating Status
Operating status can be
displayed at a remote location.
Major Optional Parts
Required
(Example of 1 : 1 system)
Relay box
(to be purchased locally)
Wired remote
controller
Details
• Operation/emergency signal
can be received at a remote
location (when channeled
through the PAC-SF40RM-E
no-voltage signal, when
channeled through the
PAC-SA88HA-E DC 12V
signal).
• Remote display panel
(to be purchased locally)
• Connector cable for remote
display
PAC-SA88HA-E/PAC-725AD
(10 pcs. x PAC-SA88HA-E)
• Relay box
(to be purchased locally)
• Remote operation adapter
PAC-SF40RM-E
*Unable to use with wireless remote controller
(Example of 1 : 1 system)
• Weekly Timer:
On/Off and up to 8 pattern
temperatures can be set for each
calendar day (initial setting).
• On/Off Timer:
On/Off can be set once each
within 72 hr in intervals of 5min.
• Auto-off Timer:
Operation will stop after a
preset time elapses. Set time
can be changed from 30min to
4hr in 10min intervals.
*Simple Timer and Auto-off Timer cannot
be used at the same time.
Standard functions of
PAR-31MAA
FUNCTIONS LIST
Category
Icon
P-Series
Indoor unit
PLY-SP18/24/30/36/42/48BA
Outdoor unit
SUY-SA18/
24/30/36VA
PUY-SP36Y/
42/48V/YKA
Opt
Opt
Combination
Technology
PCY-SP18/24/30/36/42/48KA
SUY-SA18/
24/30/36VA
PUY-SP36Y/
42/48V/YKA
PEY-SP18/24/30/36/42/48JA
SUY-SA18/
24/30/36VA
PUY-SP36Y/
42/48V/YKA
DC Inverter
Joint Lap DC Motor
Magnetic Flux Vector Sine Wave Drive
Heating Caulking (Compressor)
DC Fan Motor
Vector-Wave Eco Inverter
Pulse Amplitude Modulation (PAM)
Grooved Piping
Energy
Saving
Area Temperature Monitor
Demand Function
Attractive
Opt
Opt
Opt
Pure White
Auto Vane
Air Quality
Fresh-air Intake
High-efficiency Filter
Opt
Opt
Opt
Opt
Long-life Filter
Filter Check Signal
Air
Distribution
Horizontal Vane
High Ceiling Mode
Low Ceiling Mode
Auto Fan Speed Mode
Functions
Convenience
On/Off Operation Timer
Auto Restart
Low-noise Operation (outdoor unit)
Rotation, Back-up and 2nd Stage Cut-in Functions
System
Control
Installation
Opt
Opt
PAR-31MAA Control
Opt
Opt
Opt
Opt
Opt
Opt
Centralised On/Off Control
Opt
Opt
Opt
Opt
Opt
Opt
System Group Control
Opt
Opt
Opt
Opt
Opt
M-NET Connection
Opt
Opt
Opt
Opt
Opt
Cleaning-free Pipe Reuse
Reuse of Existing Wiring
Drain Pump
Pump Down Switch
Flare Connection
Maintenance
Opt
Self-Diagnotic Function (Check Code Display)
Failure Recall Function
• Opt: Separate parts must be purchased.
*Not available for different diameter joints.
*
*
Opt
*
Opt
Opt
Opt
Opt
Opt
Inverter Series
10-11
Pure White
Joint Lap DC Motor
Pure white is adopted for the unit colour; white expressing the essence of
cleanliness and easily matching virtually all interior décor.
Mitsubishi Electric has developed a unique motor, called
the “Poki-Poki Motor” in Japan, which is manufactured
using a joint lapping technique. This innovative motor operates based on a high-density, high-magnetic force, leading
to extremely high efficiency and reliability.
Horizontal Vane
The air outlet vane swings up and down so that the airflow is spread evenly
throughout the room.
Magnetic Flux Vector Sine Wave Drive
On/Off Operation Timer
This drive device is actually a microprocessor that converts the compressor
motor’s electrical current waveform from a conventional waveform to a sine
wave (180°conductance) to achieve higher efficiency by raising the motor winding utilisation ratio and reducing energy loss.
Use the remote controller to set the times of turning the air- conditioner On/Off.
Heat Caulking
Fixing Method
Especially useful at the time of power outages, the unit turns back on
automatically when power is restored.
Heat Caulking Fixing Method
To fix internal parts in place, a “Heat Caulking Fixing Method”
is used, replacing the former arc spot welding method. Distortion of internal parts is reduced, realising higher efficiency.
Demand Function (Onsite Adjustment)
The demand function can be activated when the unit is equipped with a commercially available timer or an On/Off switch is added to the CNDM connector (option)
on the control board of the outdoor unit. Energy consumption can be reduced up
to 100% of the normal consumption according to the signal input from outside.
DC Fan Motor
A highly efficient DC motor drives the fan of the outdoor unit. Efficiency is much
higher than an equivalent AC motor.
This inverter monitors the varying compressor motor frequency and creates the most
efficient waveform for the motor speed. As the result, operating efficiency in all speed
ranges is improved, less power is used and annual electricity cost is reduced.
Inverter size has been reduced using insertmolding, where the circuit pattern is molded into the
synthetic resin. To ensure quiet operation, soft PWM
control is used to prevent the metallic whine associated with conventional inverters.
Sine-wave drive soft PWM
SW3
Energy consumption
OFF
OFF
100%
ON
OFF
75%
ON
ON
50%
OFF
ON
0% (Stop)
✽PUY outdoor only
Long-life Filter
Filter Check Signal
Air conditioner operating time is monitored, and the user is notified when filter
maintenance is necessary.
PAM is a technology that controls the current waveform so that it resembles the
supply voltage wave, thereby reducing loss and realising more efficient use of
electricity. Using PAM control, 98% of the input power supply is used effectively.
Supply
voltage
ON
SW2
A special process for the entrapment surface improves the filtering effect, making
the maintenance cycle longer than that of units equipped with conventional filters.
PAM (Pulse Amplitude Modulation)
With PAM control
Without PAM control
[Example: PUY Series]
Limit energy consumption by changing the settings of SW7-1, SW2 and SW3
on the control board of the outdoor unit. The following settings are possible.
SW7-1
Vector-Wave Eco Inverter
Smooth wave pattern
Auto Restart
High Ceiling Mode
In the case of rooms with high ceilings, the outlet-air volume can be increased
to ensure that air is circulated all the way to the floor.
Low Ceiling Mode
Time
Current
Time
If the room has a low ceiling, the airflow volume can be reduced for less draft.
Auto Fan Speed Mode
PAM adjusts the form of the current wave so that it becomes close to that of the supply
voltage wave. High harmonics are reduced and 98% of the electricity is utilized.
■ Merits of PAM Control
Significant energy savings
Remarkable reduction in power
loss saves electricity
Limited energy savings
Electricity is wasted
The airflow speed mode adjusts the fan speed of the indoor unit automatically
according to the present room conditions.
Drain Pump
Power increased
Efficient voltage increase
realises increased power
PAM
A built-in drain pump enables
drain piping to be raised.
Conventional
inverter
Limited power
Insufficient power
when needed
Grooved Piping
High-performance grooved piping is used in heat
exchangers to increase the heat exchange area.
Built-in drain pump efficiently
pumps out water
Self-Diagnostic Function (Check Code Display)
Grooved piping
Check codes are displayed on the remote controller or the operation indicator
to inform the user of malfunctions detected.
Failure Recall Function
Cross-sectional view
Pipe image
Operation failures are recorded, allowing confirmation when needed.
MAJOR
FEATURES
■ Operating at high temperatures (52°C)
Operating range
New models
Conventional models
40°C
42°C
44°C
Extended operating range
46°C
48°C
50°C
52°C
Outdoor-air temperature
New inverter technology
New inverter technology has made it possible for units to operate at outdoor-air temperatures
as high as 52°C. Tropical Specification series units are perfect for cooling homes and offices in
tropical regions.
High dehumidifying capacity
Prevent the decrease of dehumidifying capacity even when the room temperature approaches
the preset temperature since outdoor units detect and control evaporating temperature.
New R410A lineup
From low-capacity 18,000Btu to high-capacity 48,000Btu units available, the new models in the
R410A Series have high EERs compared with conventional non-inverter models. All models contribute to reducing energy consumption over a wide range of operating capacities.
Compact Design for 5HP & 6HP Models
PUY-P (5.6HP)
• The height of the outdoor unit (5HP
& 6HP) reduces by 27% from
1,338mm to 981mm.
PUY-SP (5.6HP)
• It provides the optional solution for
small offices and shops by giving a
sleek external apperance to the
building and a clear, unobstructed
view of the scenery.
1,338
mm
981
mm
330mm
1,050mm
330mm
• Compact body opens up installation options.
1,050mm
Height 1,338mm
Height 981mm
Weight 96kg ✽
Weight 73kg ✽
✽ 6HP(3-phase) comparison
• Lighter weight provides easier installation, reducing installation time and
effort.
27% Reduction
24% Reduction
12-13
Inverter Series
4-way
Ceilingcassette
(PLY SERIES)
A sophisticated design that matches a
variety of rooms and a high level of
convenience enhancing your quality of
life are combined in this compact,
multi-functional indoor unit.
Wide Airflow
Wide-angle outlets distribute
airflow to all corners of the room,
ensuring the room is sufficiently
cooled/heated. Horizontal airflow
and a fan speed reduced by 20%
compared to conventional models
also contribute to increased
comfort for occupants.
Conventional model
PLY-SP ✽ ✽ BA
Less Cold Draft
(i-see Sensor: optional)
The horizontal airflow function
prevents cold drafts from striking
the body directly, thereby keeping
the body from becoming chilled.
Horizontal airflow prevents drafty feeling
Wide-flow Air Outlet
PLY-SP18/24/30/36/42/48BA
optional
The high-power ceiling cassettes offer a wide-flow air
outlet that enables effective
air conditioning of rooms
with atrium ceilings up to
(PLY-SP30/36/42/48BA)
4.5m in height. The demands
of high-ceiling applications such as halls,
showrooms or shopping malls can now be
fully answered thanks to this powerful, yet
highly efficient airflow.
■ Specification according to ceiling height
PLY-SP18/24BA
PLY-SP30/36/42/48BA
4-way
2.5
2.7
3.5
2.7
3.2
4.5
3-way
2.7
3.0
3.5
3.0
3.6
4.5
✽ If required to use Low Ceiling mode under high humidity conditions, please consult with your
Mitsubishi Electric dealership since there is some risk of condensation.
Automatic Air-speed Adjustment
An automatic air-speed adjustment mode is provided in addition to
the four air-speed stages, of High, Medium 1, Medium 2, and Low.
Air speed can be changed freely according to the difference
between set temperature and room temperature. The automatic
air-speed adjustment mode offers quick cooling of a room in High
mode, such as when starting cooling operation. After the room
temperature is stabilized, the system switches to Low mode automatically to maintain comfort.
Low
Medium 2
Medium 1
High
(When using the wireless remote controller, an extra setting is required.)
Automatic airspeed adjustment
Automatic Vane Shutter*
When the air conditioner is not
operating, the vane shutter closes
automatically to conceal the air
outlet and create an aesthetically
appealing flat surface.
Vane shutter closes automatically
During operation
When turned off
(optional corner panel)
The “i-see Sensor” built into the optional corner
panel eliminates uneven temperature distribution
and reduces electricity consumption.
feature will not activate when the vane is set
*atThisa fixed
position.
Unit Height of Only 258mm (PLY-SP18/24BA)
Ceiling cassette models boast a slim body height for smooth and aesthetic installation, even in narrow spaces.
PLY-SP18/24BA
With optional i-see
Sensor corner panel
PLY-SP30/36/42/48BA
“i-see Sensor” temperature-sensing technology
improves energy efficiency and enhances room comfort
“Pure White” Colour Matches Interior Décor
The colour "Pure White" has been introduced for the decoration panel
and wired remote controller so as to blend in with any interior décor.
■ i-see Sensor Operation
Quiet Operation
An improved airflow path and powerful highcapacity flow fan contribute to the realisation of
quieter operation.
The “i-see Sensor” is an innovative Mitsubishi Electric technology
that uses a radiation-based sensor to monitor temperature throughout an entire room. When connected to the air conditioner control
panel, the “i-see Sensor” works to maximize room comfort.
The “ i-see Sensor” rotates 90° at intervals of 5sec,
accurately measuring the temperature throughout
the room (covering entire floor space).
Power flow fan
90°
rotation
Other Features
• Maximum upward draining of 850mm
• Wireless remote controller available
• Duct flange for fresh-air intake
• Branch duct
Automatic Grille Lowering
Function (Option)
Easy to use/Simple maintenance
An automatic grille lowering function capable
of stopping at eight different heights is available to simplify filter maintenance.
5sec
measurement
Automatic
elevation to
4.0m
90°
rotation
5sec
measurement
90°
rotation
5sec
measurement
5sec
measurement
Sensible temperature control prevents excessive
cooling through pioneering control technology
By measuring the inlet temperature and floor temperature, temperatures felt by the human body (sensible temperature) are computed.
This allows the proper sensible temperature to always be maintained
through the suppression of excessive cooling.
1.2m
“i-see Sensor” automatically controls over-cooling
by detecting the optimum temperatures
1.6m
Example
2.0m
When you want a sensible temperature of 28°C.
Temperature set at 26 – 27˚C,
without the i-see Sensor
2.4m
Temperature set at 28˚C, with i-see Sensor
and automatic air- speed adjustment mode
Fixed condition
Fixed condition
32˚C
23˚C
Elevating (up-down)
controller
(comes with the automatic elevation panel)
2.8m
Sensible temperature: 26.5˚C
3.2m
Sensible temperature: 28˚C
Fixed condition
Fixed condition
Floor temperature
Floor temperature
Sensible temperature
Sensible temperature
3.6m
28˚ C
26.5˚ C
28˚C
26.5˚C
Inlet temperature
4.0m
Sensible temperature drops
30 minutes
The sensible temperature drops according
to the drop in floor-level temperature. If the
floor-level temperature is not monitored
during long cooling operation, the sensible
temperature becomes chilly.
Inlet temperature
No change in sensible temperature
30 minutes
Air temperature is adjusted according
to the floor temperature to keep the
sensible temperature at 28°C.
14˚C
Inverter Series
Vane Control
Fresh-air Intake
For
Shopping
Malls
Indoor air quality is significantly enhanced
by the direct intake of fresh air from outside. An optional multi-function casement
(PAC-SH53TM-E) is also available for the
intake of a larger volume of air.
Wide airflow coverage down to the floor even in
expansive spaces like large factory-outlet centers
or shopping malls with high ceilings.
The unique airflow design of the powerful ceiling-cassette models
reduces pressure loss and provides wide cool-air coverage from
high ceilings to the floor even in expansive spaces like shopping
malls with ceilings over 4 metres in height.
4-way outlets (for high-ceiling applications)
Remote control setting for
four directions
4.5m*
*PLY-SP30 and above
For Retail
Outlets
(e.g. grocery
stores)
These units are ideal for maintaining constant
temperatures in environments that have
equipment such as refrigerated showcases.
Individual vane angle adjustment enables precise airflow control to
specific areas of the store to reduce unnecessary air conditioning
of areas such as refrigerated showcases.
4-way outlets
Remote control setting for two directions
Fixed
Fixed
Top or bottom
airflow setting via
remote controller
Fixed
Drain Water Lifting Mechanism
A high-performance drain pump on
the drain water lifting mechanism
allows the drain water pipe to be
routed as high as 850mm from the
ceiling surface.
Handy Corner Pocket Design
Simplifies Maintenance
By using the handy pockets equipped on the
four corners of the grille, maintenance work
such as drain pan cleaning and height adjustments can be accomplished without removing the grille.
Bacteria- and Mold-resistant Specifications
Mitsubishi Electric filters are bacteria-resistant, and the drain pans are
designed to prevent the growth of mold for fresh and pleasant air
conditioning at all times.
Compatible with Round and Rectangular Ducts
For easy connection to branch ducts, knock-out holes are designed to
fit both round and rectangular ducts. Matching the shape of the duct
fringe provides more flexibility during installation.
Refrigerated
showcase not
affected by air
conditioning
Fixed
For
Offices
Fixed vane for two directions
14-15
Flexible and pleasant airflow eliminates
annoying drafts within the office environment.
Connecting to round ducts
Connecting to rectangular ducts
150mm diameter cutout
350mm x 100mm cutout
In office environments, annoying drafts can be bothersome, leading to discomfort and reduced productivity. Precise vane control
helps to eliminate this problem.
4-way outlets
Remote control setting for two directions
Fixed
Top or bottom
airflow setting via
remote controller
Fixed
Top or bottom
airflow setting via
remote controller
Fixed vane for two directions
Features at a glance
Fixed
Separate vane
adjustments allow
different settings
per vane for a more
flexible airflow
Female employee who
dislikes an excessively
cool environment.
Fixed
Male employee who
likes the environment to
be as cool as possible.
Installation & Maintenance
• Chargeless system
• Compact design
• Drain water lifting (850mm)
• Handy corner pocket
• Long-life filter (2500hr)*
• Self-diagnostic function
• Filter indicator
(for wired remote controller)
• Flockless vanes
• Elevation grille
Comfort
• i- see Sensor
• Auto fan speed
• Wide vane
• Smudge/ draft- free
• High- ceiling application
• Computerized dehumidifier
• Quiet operation
• Bacteria- and mold- resistant filter
*May vary according to operating conditions.
Others
• System control
• Auto vane shutter
• Auto restart
• Fresh- air intake
• Outdoor unit max.
operating temp. of 52ºC
Ceilingconcealed
The thin, ceiling-concealed indoor units
of the PEY series are the perfect answer
for the air-conditioning requirements of
buildings with minimum ceiling installation
space and wide-ranging external static
pressure. Energy-saving efficiency has
been improved, thereby reducing electricity
consumption and contributing to a further
reduction in operating cost.
Compact Indoor Units
(PEY SERIES)
For all models, unit height is unified to 250mm. Compared to the previous model, height has been reduced, allowing installation in tight
spaces such as ceiling cavities or drop-ceilings.
Height reduced
250mm
Air Inlet
Units with bottom inlets make more noise than those with rear
inlets. It is recommended that the rear inlet be selected when
installing a unit in a room that should be quiet, such as a bedroom.
(1) Rear inlet
(2) Bottom inlet
Air inlet
Air inlet
PEY-SP18/24/30/36/42/48JA
Air outlet
optional
optional
Air outlet
Wide Selection of Fan Speeds and External
Static Pressure
Five-stage external static pressure conversions and three fan
speed selections are available. Capable of being set to a maximum
of 125Pa, units are applicable to a wide range of building types.
■ External static pressure setting
Series
18
PEY-SP . JA
24
30
36
42
35/ 50/ 70/ 100/ 125P a
■ Flexible duct design
Features at a glance
Installation & Maintenance
• Chargeless system
• Smooth installation
• Self-diagnostic function
Comfort
• Computerized dehumidifier
• Quiet operation
Others
• System control
• Auto restart
• Outdoor unit max.
operating temp. of 52ºC
48
16-17
Inverter Series
Ceilingsuspended
A stylish indoor unit design and airflow
settings for both high- and low-ceiling
interiors expand installation possibilities
Stylish Indoor Unit Design
PC-GAKD
A stylish square-like design is adopted for
the indoor units of all models. As a result,
the units blend in better with the ceiling.
PCY-SP ✽ ✽ K A
Optional Drain Pump for
Full-capacity Models
(PCY SERIES)
The pumping height of
the optional drain pump
has been increased
from 400mm to 600mm,
expanding flexibility in
choosing unit location
during installation work.
Drain pump installation
possible
Drainage outlet can be
600mm above ceiling surface
Ceiling
surface
Automatic Air-speed Adjustment
In addition to the conventional 4-speed setting, units are now
equipped with an automatic air-speed adjustment mode. This
setting automatically adjusts the air-speed to conditions that
match the room environment. At the start of cooling operation,
the airflow is set to high-speed to quickly cool the room. When
the room temperature reaches the desired setting, the
airflow speed is decreased automatically for stable, comfortable cooling operation.
PCY-SP18/24/30/36/42/48KA
Strong
optional
Start of cooling…
After room
temperature is stabilised…
Fresh-air Intake
Units are equipped with
a knock-out hole that
enables the induction of
fresh air from outside.
● Fresh-air intake characteristics
Static pressure (Pa)
optional
Gentle
50
0
–50
–100
–150
–200
–250
–300
PCY-SP30/36/42/48/KA
PCY-SP18/24KA
0
1
2
3
Airflow volume (m 3/min)
4
Flockless Vanes
With the adoption of flockless vanes, dirt and other impurities
can be cleaned off easily using a mild household detergent.
Features at a glance
Installation & Maintenance
• Chargeless system
• New direct suspension system
• Drain water lifting (600mm)*1
• Flexible piping
• Long-life filter (2500hr)*2
• High-efficiency filter*1
• Self-diagnostic function
Comfort
• Auto swing
• Computerized dehumidifier
• Quiet operation
*1 Optional
*2 May vary according to operating conditions.
Others
• System control
• Auto restart
• Auto vane shutter
• Outdoor unit max. operating
temp. of 52ºC
SPECIFICATIONS
4-way ceiling-cassette (50Hz/60Hz)
PLY SERIES
Models
Cooling capacity
Cooling capacity
Total input
EER
Model name
kW
BTU/h
kW
W/W
Power supply
External finish
CMM
CFM
External static pressure
Pa
Operation control and thermostat
Noise level (low-med2-med1-high) dB (A)
Unit drain pipe (outer diameter) mm
W
mm
Dimensions (panel)
D
mm
H
mm
Weight (panel)
kg
Model name
Airflow
(low-med2-med1-high)
Indoor
unit
Power supply
External finish
Refrigerant (R410A) control
Airflow
Outdoor
unit
Noise level
W
D
H
Dimensions
Weight
Max. height difference
Max. piping length
CMM
CFM
dB (A)
mm
mm
mm
kg
m
m
Pipe size (outer diameter)
mm
Chargeless piping length
m
Guaranteed Operating Range
PLY-SP18BA
5.3 (2.8-5.3)
18,000
1.73
3.06
PLY-SP18BA
PLY-SP24BA
7.1 (2.9-7.1)
24,000
2.22
3.19
PLY-SP24BA
PLY-SP30BA
8.8 (3.8-8.8)
30,000
2.94
2.99
PLY-SP30BA
PLY-SP36BA
PLY-SP36BA
PLY-SP42BA
PLY-SP42BA
PLY-SP48BA
PLY-SP48BA
10.6 (4.0-10.6) 10.6 (5.3-10.6)
12.3 (6.1-12.3)
14.1 (7.0-14.1)
36,000
42,000
48,000
3.13
3.34
4.37
6.07
3.38
3.17
2.81
2.32
PLY-SP36BA
PLY-SP36BA
PLY-SP42BA
PLY-SP42BA
PLY-SP48BA
PLY-SP48BA
1ph 220-240V 50Hz
1ph 220V 60Hz
Munsell 6.4Y 8.9/0.4
12-13-14-16
14-16-18-20
20-22-25-28
24-26-29-32
425-460-495-565 495-565-635-705 705-775-885-990
850-920-1025-1130
0 (direct blow)
Remote control and Built-in
28-29-30-32
28-30-32-34
33-35-38-41
37-39-41-44
32
840 (950)
840 (950)
258 (35)
298 (35)
19 (6)
22 (6)
24 (6)
26 (6)
SUY-SA18VA
SUY-SA24VA
SUY-SA30VA
SUY-SA36VA PUY-SP36YKA PUY-SP42VKA PUY-SP42YKA PUY-SP48VKA PUY-SP48YKA
3ph 380-415V 50Hz 1ph 220-240V 50Hz 3ph 380-415V 50Hz 1ph 220-240V 50Hz 3ph 380-415V 50Hz
1ph 220-240V 50Hz
3ph 380 60Hz
1ph 220V 60Hz
3ph 380 60Hz
1ph 220V 60Hz
3ph 380 60Hz
1ph 220V 60Hz
Munsell 3.0Y 7.8/1.1
Linear expansion valve
27
46
51
75
87
953
1625
1800
2648
3071
47
52
54
52
53
56
800
840
1050
285
330
330
550
880
981
32
49
47
51
73
72
73
72
73
12
15
30
20
30
50
Liquid: 6.35
Liquid: 9.52
Liquid: 9.52
Gas: 12.7
Gas: 15.88
Gas: 15.88
7
10
Upper limit (DB)
Lower limit (DB)
52
18
Ceiling-concealed (50Hz/60Hz)
PEY SERIES
Models
Cooling capacity
Cooling capacity
Total input
EER
Model name
kW
BTU/h
kW
W/W
PEY-SP18JA
5.3 (2.8-5.3)
18,000
1.72
3.08
PEY-SP18JA
Power supply
External finish
CMM
CFM
External static pressure
Pa
Operation control and thermostat
Noise level (low-med2-med1-high) dB (A)
Unit drain pipe (outer diameter) mm
W
mm
Dimensions
D
mm
H
mm
Weight
kg
Model name
Airflow
(low-med2-med1-high)
Indoor
unit
12-14.5-17
425-510-600
30-35-39
900
27
SUY-SA18VA
Power supply
External finish
Refrigerant (R410A) control
Airflow
Outdoor
unit
Noise level
Dimensions
Weight
Max. height difference
Max. piping length
W
D
H
CMM
CFM
dB (A)
mm
mm
mm
kg
m
m
Pipe size (outer diameter)
mm
Chargeless piping length
m
Guaranteed Operating Range
Upper limit (DB)
Lower limit (DB)
27
953
47
800
285
550
32
12
20
Liquid: 6.35
Gas: 12.7
PEY-SP24JA
7.1 (2.9-7.1)
24,000
2.16
3.28
PEY-SP24JA
PEY-SP30JA
8.8 (3.8-8.8)
30,000
2.90
3.03
PEY-SP30JA
PEY-SP36JA
PEY-SP36JA
PEY-SP42JA
PEY-SP42JA
PEY-SP48JA
PEY-SP48JA
10.6 (4.0-10.6) 10.6 (5.3-10.6)
12.3 (6.1-12.3)
14.1 (7.0-14.1)
36,000
42,000
48,000
3.33
3.31
4.59
5.73
3.18
3.20
2.67
2.46
PEY-SP36JA
PEY-SP36JA
PEY-SP42JA
PEY-SP42JA
PEY-SP48JA
PEY-SP48JA
1ph 220-240V 50Hz
1ph 220V 60Hz
Galvanized sheet
17.5-21-25
24-29-34
29.5-35.5-42
1040-1225-1485
620-740-885 850-1025-1200
35-50-70-100-125
Remote control and Built-in
30-34-39
33-38-42
36-40-44
32
1100
1400
732
250
29
38
39
PUY-SP36YKA PUY-SP42VKA PUY-SP42YKA PUY-SP48VKA PUY-SP48YKA
SUY-SA24VA
SUY-SA30VA
SUY-SA36VA
3ph 380-415V 50Hz 1ph 220-240V 50Hz 3ph 380-415V 50Hz 1ph 220-240V 50Hz 3ph 380-415V 50Hz
1ph 220-240V 50Hz
3ph 380 60Hz
1ph 220V 60Hz
3ph 380 60Hz
1ph 220V 60Hz
3ph 380 60Hz
1ph 220V 60Hz
Munsell 3.0Y 7.8/1.1
Linear expansion valve
46
51
75
87
1625
1800
2648
3071
52
54
52
53
56
840
1050
330
330
880
981
49
47
51
73
72
73
72
73
15
30
30
50
Liquid: 9.52
Liquid: 9.52
Gas: 15.88
Gas: 15.88
7
10
52
18
Inverter Series
18-19
Ceiling-suspended (50Hz/60Hz)
PCY SERIES
Models
Cooling capacity
Cooling capacity
Total input
EER
Model name
kW
BTU/h
kW
W/W
Power supply
External finish
CMM
CFM
External static pressure
Pa
Operation control and thermostat
Noise level (low-med2-med1-high) dB (A)
Unit drain pipe (outer diameter) mm
W
mm
Dimensions
D
mm
H
mm
Weight
kg
Model name
Airflow
(low-med2-med1-high)
Indoor
unit
Power supply
External finish
Refrigerant (R410A) control
Airflow
Outdoor
unit
Noise level
Dimensions
Weight
Max. height difference
Max. piping length
W
D
H
CMM
CFM
dB (A)
mm
mm
mm
kg
m
m
Pipe size (outer diameter)
mm
Chargeless piping length
m
Guaranteed Operating Range
PCY-SP18KA
5.3 (2.8-5.3)
18,000
1.58
3.35
PCY-SP18KA
PCY-SP24KA
7.1 (2.9-7.1)
24,000
2.19
3.24
PCY-SP24KA
PCY-SP30KA
8.8 (3.8-8.8)
30,000
2.95
2.98
PCY-SP30KA
PCY-SP36KA
PCY-SP36KA
PCY-SP42KA
PCY-SP42KA
PCY-SP48KA
PCY-SP48KA
10.6 (4.0-10.6) 10.6 (5.3-10.6)
12.3 (6.1-12.3)
14.1 (7.0-14.1)
36,000
42,000
48,000
3.18
3.37
4.58
5.75
3.33
3.14
2.68
2.45
PCY-SP36KA
PCY-SP36KA
PCY-SP42KA
PCY-SP42KA
PCY-SP48KA
PCY-SP48KA
1ph 220-240V 50Hz
1ph 220V 60Hz
Munsell 6.4Y 8.9/0.4
16-17-18-20
16-18-20-22
24-26-28-30
27-29-32-34
565-600-635-705 565-635-705-775 850-920-990-1060
955-1025-1130-1200
0 (direct blow)
Remote control and Built-in
34-36-38-40
34-36-40-42
39-41-43-45
42-44-46-48
26
1280
1600
680
230
32
37
40
SUY-SA18VA
SUY-SA24VA
SUY-SA30VA
SUY-SA36VA PUY-SP36YKA PUY-SP42VKA PUY-SP42YKA PUY-SP48VKA PUY-SP48YKA
3ph 380-415V 50Hz 1ph 220-240V 50Hz 3ph 380-415V 50Hz 1ph 220-240V 50Hz 3ph 380-415V 50Hz
1ph 220-240V 50Hz
3ph 380 60Hz
1ph 220V 60Hz
3ph 380 60Hz
1ph 220V 60Hz
3ph 380 60Hz
1ph 220V 60Hz
Munsell 3.0Y 7.8/1.1
Linear expansion valve
27
46
51
75
87
953
1625
1800
2648
3071
47
52
54
52
53
56
800
840
1050
285
330
550
880
981
32
49
47
51
73
72
73
72
73
12
15
30
20
30
50
Liquid: 6.35
Liquid: 9.52
Gas: 12.7
Gas: 15.88
7
10
Upper limit (DB)
Lower limit (DB)
• Rating conditions Cooling - Indoor: 27℃ (80℉) DB, 19℃ (66℉) WB, Outdoor: 35℃ (95℉) DB
• Refrigerant piping length (one-way): 7.5m( 25ft)
• Total input based on the indicated voltage (indoor/outdoor): 1ph 230V 50Hz, 3ph 400V 50Hz
52
18
EXTERNAL
DIMENSIONS
Unit : mm
PEY-SP18JA PEY-SP24JA PEY-SP30JA PEY-SP36JA
PEY-SP42JA PEY-SP48JA
PLY-SP18BA PLY-SP24BA PLY-SP30BA PLY-SP36BA
PLY-SP42BA PLY-SP48BA
INDOOR UNIT
INDOOR UNIT
90 100 100 90
Ceiling
Power supply wire,
Grille
Control
Indoor unit/Outdoor unit
wire entry connecting wire entry
Keep approximately
10 to 15mm space
between unit ceiling
and ceiling slab.
PLY-SP24BA
PLY-SP30BA
PLY-SP36BA
PLY-SP42BA
PLY-SP48BA
155
167
350
ø175
Burring hole pitch
Refrigerant pipe
···ø6.35
Flared connection
···1/4 F
1
2
A B C D
Refrigerant pipe
···ø12.7
80 74
Flared connection 241 258
···1/2 F
Refrigerant pipe
···ø9.52
Flared connection
···3/8 F
Refrigerant pipe
···ø15.88
85 77
Flared connection 281 298
···5/8 F
14-ø2.8
Burring hole
ø150
Cut out hole
10
Refrigerant piping
Flare connection (liquid)
32
2x2- 2.9
Refrigerant piping
Flare connection (gas)
Models
PEY-SP18JA
PEY-SP24JA
PEY-SP30JA
PEY-SP36JA
PEY-SP42JA
PEY-SP48JA
10
136
Drain pipe (O.D. 32)
A
900
1100
B
C
954 1000
1154 1200
D
860
1060
E
9
11
F
800
1000
G
858
1058
1400
1454 1500
1360
14
1300
1358
51
2
1600
1493
2
A
B
233
246
(liquid ø C)
(gas ø D)
When drain socket
is installed
(Drainage)
(
Terminal block
(Indoor/Outdoor
connecting line)
)
680
254
476
85
Models
PCY-SP18KA
PCY-SP24KA
A
184
180
B
203
200
C
D
6.35 12.7
9.52 15.88
51
180 (liquid ø9.52)
200 (gas ø15.88)
233
When drain socket
is installed
246
(Drainage)
(
254
182
10
5
84 88
195
230
Air outlet
476
680
57
Air outlet
57
10
5
(236)
2
84 88
195
230
1280
1173
Air intake
A
B (Suspension bolt pitch)
C
Control box
67
356
INDOOR UNIT
INDOOR UNIT
1198
Terminal block
(Remote controller
transmission line)
732
700
PCY-SP30KA PCY-SP36KA PCY-SP42KA PCY-SP48KA
PCY-SP18KA PCY-SP24KA
2
643 (Suspension bolt pitch)
57
(236)
Models
PLY-SP18BA
Cut out hole
78 20
30
57
100
17 +50
35
170
140
50~70
)
23
40
122
(
Detail connecting of branch duct(Both aspects)
105
156
190
A
B
2
Drain pipe
connected to VP-25
Connect the attached
drain socket.
178(Duct)
100
377
Air
inlet
33
284
24
840
Air
outlet
100
130
1
60
160
70
Suspension bolt
M10 or W3/8
20~45
24
160
(7.5)
187.5
Suspension bolt
lower edge
Branch duct hole
23
Indoor power supply
terminal block(Option part)
Suspension bolt hole
4-14x30 Slot
15
217
250
Remote controller
terminal block
Indoor unit/Outdoor unit
connecting terminal block
Branch
duct hole
150
90
C
D
840
160
160
2xE- 2.9
20~45
D (Duct)
100x(E-1)=F
Fresh air
intake hole
Ceiling hole
860~910
810
Suspension bolt pitch
Suspension bolt pitch
605 +35
(7.5)
-5
620
860~910
20~45
Ceiling hole
20~45
1518
Air intake
182
85
)
Inverter Series
Unit : mm
SUY-SA24VA SUY-SA30VA SUY-SA36VA
SUY-SA18VA
OUTDOOR UNIT
417.5
Drain hole ø42
Air in
40
Air in
Air out
17.5
40
330
Bolt pitch for
installation
360
Air in
344.5
Bolt pitch for
installation
304~325
44
50
Air in
D
ø4 rain
2 h
ol
e
OUTDOOR UNIT
400
175
2-10×21 Oval holes
Air out
840
23
22.3
2-10×21 Oval holes
500 Bolt pitch for installation
81
Service panel
Service panel
Handle
69
880
Gas refrigerant pipe joint
170.5
800
99.5 65
164.5
99.5
280
10
Bolt pitch for installation
Liquid refrigerant
pipe joint
Service port
109
PUY-SP36YKA PUY-SP42V/YKA PUY-SP48V/YKA
OUTDOOR UNIT
225
600
Installation Feet
2-U Shaped notched holes
(Foundation Bolt M10)
225
19
Rear Air Intake
Air Discharge
47
75
417
54
40
0
52
26
25
372
330
Side Air Intake
57
2-12×36 Oval holes
(Foundation Bolt M10)
1050
Handle for moving
362
Earth terminal
Terminal connection
Left • • • Power supply wiring
Right • • Indoor/Outdoor wiring
Service panel
Handle for moving
631
1
26
*1 390
2
*1 374
498
981
Air intake
Front piping cover
Rear piping cover
1 ···Refrigerant GAS pipe connection (FLARE) ø15.88(5/8F)
2 ···Refrigerant LIQUID pipe connection (FLARE) ø9.52(3/8F)
*1 ···Indication of STOP VALVE connection location.
35° 44°
150
500
302.5
43°
35°
550
Liquid refrigerant pipe joint
452
285
20-21
195
Service port
Gas refrigerant pipe joint
NOTE &
OUTDOOR UNIT
Notes for All Specifications
Total input based on the indicated voltage (indoor/outdoor)
Rating conditions
Cooling - Indoor: 27°C (80°F) DB, 19°C (66°F) WB
Outdoor: 35°C (95°F) DB
Outdoor
Indoor
Refrigerant piping length (one-way): 7.5m (25ft)
18/24/30/36/42/48V
36/42/48Y
50Hz
Single-phase, 220-240V
Single-phase, 220-240V
Three-phase, 380-415V
60Hz
Single-phase, 220V
Single-phase, 220V
Three-phase, 380V
Guaranteed Operating Range
Cooling
SUY-SA
PUY-SP
Upper limit (DB)
52°C
52°C
Lower limit (DB)
18°C
18°C
Sound Pressure Level
• Sound pressure measurements were conducted in an anechoic chamber.
• The actual noise level depends on the distance from the unit and the acoustic environment.
Refrigerant Piping
Between indoor and outdoor units
Capacity
Max. height difference (m)
Max. piping length (m)
12
20
SUY-SA18
SUY-SA24/30/36
15
PUY-SP36YKA
PUY-SP42V/YKA
PUY-SP48V/YKA
Pipe size (mm, outer dia.)
Thickness (mm)
Liquid: ø6.35
t 0.8
Gas:
ø12.7
t 0.8
Liquid: ø9.52
t 0.8
Gas: ø15.88
t 1.0
Liquid: ø9.52
t 0.8
Gas: ø15.88
t 1.0
30
30
50
Refrigerant Requirements ( R410A: kg)
Factory charged
Piping length
7m
Additional charge
10m
15m
20m
25m
30m
35m
40m
45m
50m
SUY-SA18
1.2
0.05
0.12
0.2
—
—
—
—
—
—
SUY-SA24
2.0
0.06
0.16
0.26
0.36
0.46
—
—
—
—
SUY-SA30
2.1
0.06
0.16
0.26
0.36
0.46
—
—
—
—
SUY-SA36
2.5
0.06
0.16
0.26
0.36
0.46
—
—
—
—
PUY-SP36YKA
PUY-SP42V/YKA
PUY-SP48V/YKA
2.8
0
0.15
0.30
0.45
0.60
0.75
0.90
1.05
1.20
• When installing a single outdoor unit
<S Series>
nSUY-SA18VA
A
B
C
D
nSUY-SA24VA
nSUY-SA30VA
nSUY-SA36VA
SUY-SA18VA
100mm or more
200mm or more
Calculation
Xg = 15g/m × (length-7) m
Xg = 20g/m × (length-7) m
Xg=30g/m x (length-10)m
<P Series>
nPUY-SP36YKA
nPUY-SP42V/YKA
nPUY-SP48V/YKA
SUY-SA24, 30, 36VA
100mm or more
350mm or more
500mm or more
—
[Notice] If there is any obstruction around the unit, check the condition details in the Data Book.
A
B
C
D
E
PUY-SP36YKA PUY-SP42, 48V/YKA
250mm or more
250mm or more
1,500mm or more
Free
500mm or more
Inverter Series
22-23
Optional Parts
Part name
Drain pump
Model name
Application name
PAC-SH83DM-E
PCY-SP18
PAC-SH84DM-E
PCY-SP24/30/36/42/48
Insulation for high humidity condition
PAC-SH62HK-E
PLY-SP
Flange for fresh-air intake
PAC-SH65OF-E
PLY-SP
MAC-333IF-E
All indoor units
Wireless remote controller
PAR-SL97A-E
PLY-SP / PEY-SP
Wireless remote controller
signal receiver
PAR-SA9CA-E
PEY-SP
M-NET and Terminal interface
High-efficiency filter
High-efficiency filter element
Filter box
i-see sensor corner panel
PAR-SA9FA-E
PLY-SP
PAC-SH89KF-E
PCY-SP18/24
PAC-SH90KF-E
PCY-SP30/36/42/48
PAC-SH59KF-E
PLY-SP
PAC-KE92TB-E
PEY-SP18
PAC-KE93TB-E
PEY-SP24
PAC-KE94TB-E
PEY-SP30/36/42/48
PAC-SA1ME-E
PLY-SP
PLY-SP
Shutter plate
PAC-SH51SP-E
Multi-function casement
PAC-SH53TM-E
PLY-SP
Remote On/Off adaptor
PAC-SE55RA-E
All indoor units
Remote operation adaptor
PAC-SF40RM-E
All indoor units
Remote sensor
PAC-SE41TS-E
All indoor units
Space panel
PAC-SH48AS-E
PLY-SP
Connector cable for remote display
PAC-SA88HA-E
All indoor units
PAR-31MAA
All indoor units
PAR-21MAA
All indoor units
PAR-SL94B-E
PCY-SP
PAC-725AD
All indoor units
Wired remote controller
Wireless remote controller kit
(Sender & Receiver)
Multiple remote controller adaptor
MAC-881SG
SUY-SA18
MAC-886SG-E
SUY-SA24/30/36
PAC-SG73RJ-E
PUY-SP36Y/42/48
PAC-SG75RJ-E
PUY-SP36Y/42/48
Filter dryer for liquid pipe
PAC-SG82DR-E
PUY-SP36Y/42/48
Air outlet guide
PAC-SH96SG-E
PUY-SP36Y/42/48
Air protection guide
PAC-SH95AG-E
PUY-SP36Y/42/48
Drain socket
PAC-SG61DS-E
PUY-SP36Y/42/48
Centralized drain pan
PAC-SH97DP-E
PUY-SP36Y/42/48
M-Net converter
PAC-SF83MA-E
PUY-SP36Y/42/48
PAC-SK52ST
PUY-SP36Y/42/48
PAC-SC36NA-E
PUY-SP36Y/42/48
Air discharge guide
Joint pipe
Control/Service tool
External/Input adapter
Notice
■ Do not install indoor units in areas where the emission of VOCs such as phthalate compounds and formaldehyde is known to
be high (e.g., mobile phone base stations) as this may result in a chemical reaction.
■ When installing, relocating or servicing air conditioners, use only the specified refrigerant (R410A) to charge the refrigerant lines.
Do not mix R410A with any other refrigerant and do not allow air to remain in the lines.
If air is mixed with the refrigerant, this may cause abnormal high pressure in the refrigerant lines and possibly result in an
explosion or other hazard.
The use of any refrigerant other than that specified for the system will cause mechanical failure, system malfunction or unit
breakdown. In the worst case, it could lead to a serious impediment to securing product safety.
The MEQ Difference
Simply meeting industry standards, however stringent, is not enough.
Our aim is to exceed them. When it comes to comfort, efficiency and durability,
Mitsubishi Electric offers you a distinctive advantage. We call it MEQ —
Mitsubishi Electric Quality. It results in benchmark leading-edge products like our
air conditioners, which consume minimal power, protect your investment through
a long service life, offer superior reliability and are built to take the punishment of
extreme weather conditions year in and year out.
Mitsubishi Electric Offers
Three Important Advantages
Comfort
Efficiency
Durability
Clean air, optimum temperature
distribution and silent operation...
Optimum cost performance and
energy savings...
Rugged construction, rigorous
testing, long-lasting operation...
MEQ has led to the development
of state-of-the-art air purification
and deodorization filters that
remove unwanted odors and
impurities in the air. Original airflow
technologies and specially
designed components provide
even temperature distribution —
even in remote regions of a room.
At Mitsubishi Electric, comfort
doesn't simply mean cool or warm,
it means clean and quiet too.
MEQ results in air conditioners
that are rated among the best in
the industry in terms of quality
and energy efficiency. We strive
for a perfect balance of performance, reliability, low power
consumption and long service life.
This is complemented by continuously introducing new technologies
and components that further
reduce energy requirements and
negative environmental impact.
MEQ is behind a mindset that goes
to extremes to ensure higher quality
products that protect the initial
investment over years of reliable
service. We subject our indoor and
outdoor units to rigorous durability
testing, including harsher temperature extremes than likely found
anywhere in the world.
HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
http://Global.MitsubishiElectric.com
(84) 28 3910 5945 - Fax: (84) 28 3910 5947
(84) 24 3937 8075 - Fax: (84) 24 3937 8076
(84) 236 365 6245 - Fax: (84) 236 365 6246
Ver. 05/2017