vc-1008 graphic display multi- meter highlights

VOLTC RA F T ® - TOP P ERFORMA NCE IN EVERY WAY
“For more than 25 years, our product range has been dynamically adapting to the constant changes in the industry.
We commit to offering first-class quality to our customers while delivering an excellent cost-performance ratio. This
philosophy remains the cornerstone of Voltcraft’s success.”
VC-1008
G RAP H IC DISPLAY M ULT I ­
M E TER
VERSION 09/14
N º 1 2 2 38 8
The VC-1008 combines the functions of a high-value hand held oscilloscope with those of a multimeter.
H IG HL IGH TS
H an d h e l d os c illos cope a nd multimeter in o n e in stru ment //
CAT II 1 0 0 0 V / CAT I I I 60 0 V //
B an dw i d th 8 M Hz //
Sam p l i n g ra te 40 MS/s rea l time //
S i ze of LC d i s play (1 60 x 1 60 pixe ls) //
4 0 0 0 co u n t multimeter w ith mea surement fu n ctio ns
fo r D C / V, AC / V, DC /A , AC /A , resistan ce, capac itan ce,
freq u e n cy, d i ode test, a ccoustic co ntinuity ch ecker,
d u ty cyc l e / /
Au to m a t i c ra n ge s election (a utos electio n) //
Tr u e RM S / /
D i s p l ay l i g h ti ng //
B arg ra p h / /
TEC H N ICA L DATA
Display
Graphic dot matrix LCD (160 x 160 pixels)
DMM 4000 counts (display 3999)
Input resistance
approx. 10MW
Operating voltage
approx. 4.8 6 V (4xAA) accumulator/battery operation 6
V/DC input voltage power pack socket
Current consumption
max. 130 mA
Operating temperature
0 to +40°C
Storage temperature
-10 to +50°C
Rel. air humidity
< 75%, non-condensing from 0°C to 40°C
Temp. for guaranteed accuracy
+18 to +28°C
Weight (incl. battery)
Approx. 540 g
Dimensions (HxWxD)
200 x 100 x 50 (mm)
Direct voltage range, overload protection 1000 V/DC
Range
Accuracy
Resolution
400 mV
0.1 mV
4V
1 mV
±(0.8% + 8 dgt)
40 V
10 mV
400 V
100 mV
±(1% + 8 dgt)
1000 V
1V
Alternate voltage range (40 Hz to 400 kHz), overload protection 750 V/AC
Range
Accuracy
Resolution
4V
1 mV
±(1% + 15 dgt)
40 V
10 mV
400 V
100 mV
±(1.2% + 15 dgt)
750 V
1V
Direct current range
Range
400 µA
4000 µA
40 mA
400mA
4A
10 A
Accuracy
±(1% + 8 dgt)
±(1.2% + 8 dgt)
±(1.5% + 8 dgt)
Resolution
Fuse
0.1 µA
1 µA
0.01 mA
F 500mA/250V
0.1 mA
1 mA
10 mA
F 10A/250V
Alternate current range (40 Hz to 5 KHz), overload protection 500 mA / 250 V/AC
Range
400 µA
4000 µA
40 mA
400mA
4A
10 A
Accuracy
±(1.5% + 8 dgt)
±(2% + 8 dgt)
±(2.5% + 5 dgt)
Resolution
Fuse
0.1 µA
1 µA
0.01 mA
F 500mA/250V
0.1 mA
1 mA
10 mA
F 10A/250V
PAC KAGE CONT ENT
Measurement lines // BNC adapter // 4 mignon batteries (type AA) // USB interface cable demo software // Operating
instructions
This data sheet is published by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data processing
systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This data sheet represents the technical status at the
time of printing.
© Copyright 2014 by Conrad Electronic SE.
V2_0914_02-ETS-Mkde