Replacing the Fan Tray
• Required Tools, page 1
• Removing the Fan Tray, page 1
• Installing the Fan Tray, page 3
• Checking the Installation, page 3
• Finding the Fan Serial Number, page 4
Required Tools
You might need a flat-blade or number 2 Phillips-head screwdriver to loosen or tighten the captive installation
screws on the fan tray.
Removing the Fan Tray
The fan tray is designed to be removed and replaced while the system is operating without presenting an
electrical hazard or damage to the system.
Note
Warning
You have 120 seconds to remove and insert of the fan-tray, under specified ambient operating temperatures.
The fans might still be turning when you remove the fan from the chassis. Keep fingers, screwdrivers,
and other objects away from the openings in the fan’s housing. Statement 263
Procedure
Step 1
Locate the fan tray as shown in the figure.
Catalyst 6880-X Switch Hardware Installation Guide
OL-30827-02
1
Replacing the Fan Tray
Removing the Fan Tray
Note
Make sure there is adequate slack in the network interface cables to allow the cable guide to pivot
down far enough to access the fan tray. If there is insufficient slack in the cables, the cable guide will
not pivot far enough to give you access to the fan trays.
Figure 1: Fan Tray Location
1
Step 2
Step 3
Step 4
Location of fan tray
Loosen the fan tray captive installation screw by turning it counterclockwise.
Grasp the fan tray, and pull it outward; gently move side to side, if necessary, to unseat the fan tray power
connector from the backplane.
Caution
When removing the fan tray, keep your hands and fingers away from the spinning fan blades. Let
the fan blades stop completely before you remove the fan tray.
Pull the fan tray clear of the chassis, and set it aside.
Figure 2: Removing the Fan Tray
Catalyst 6880-X Switch Hardware Installation Guide
2
OL-30827-02
Replacing the Fan Tray
Installing the Fan Tray
Installing the Fan Tray
Procedure
Step 1
Step 2
Step 3
Step 4
Position the fan tray with the captive installation screws in front of the fan tray cavity.
Place the fan tray into the chassis cavity so that it rests on the chassis, and then lift the fan tray up slightly,
aligning the top and bottom chassis guides.
Push the fan tray into the chassis until the power connector seats in the backplane and the captive installation
screw make contact with the chassis.
Tighten the captive installation screws.
Related Topics
Cooling with the Fan Tray
Checking the Installation
Procedure
Step 1
Step 2
Listen for the fans; you should immediately hear them operating. If you do not hear them, ensure that the fan
tray is inserted completely in the chassis and that the faceplate is flush with the switch back panel.
Verify that the FAN STATUS LED is green. If the LED is red, one or more of the fans are faulty.
If after several attempts the fans do not operate or if you experience trouble with the installation (for instance,
if the captive installation screws do not align with the chassis holes), contact a Cisco customer service
representative for assistance.
Catalyst 6880-X Switch Hardware Installation Guide
OL-30827-02
3
Replacing the Fan Tray
Finding the Fan Serial Number
Finding the Fan Serial Number
If you contact Cisco Technical Assistance, you need to know the fan serial number. This figure shows where
the serial number is located. You can also use the show version privileged EXEC command to see the serial
number. For more information, refer to Fan Tray LEDs
Figure 3: Serial Number on the Fan
Catalyst 6880-X Switch Hardware Installation Guide
4
OL-30827-02