PSF132UM.qxd 08/04/2004 09:00 Page 1 MINERVA® Marine 601F-M & 601FEx-M Conventional InfraRed Flame Detectors Features: Unlike UV and UV/IR detection, not blinded by oil mist in machinery spaces Reduces cabling, no interface required No additional power source required Easy installation, uses a common plug in base for smoke and heat detectors Can be used on all vessels as fully marine approved Standard or Intrinsically Safe ATEX approved The 601F-M and 601FEx-M point type flame detectors form part of the 600 series of conventional detectors. The range includes heat, optical, ionisation and carbon monoxide detection technologies and with the addition of the 601F-M and 601FEx-M now encompasses infrared flame detection. Both the 601F-M and the 601FEx-M are full featured solar blind flame detectors for enclosed use and boast a high degree of false alarm immunity. The standard unit is the 601F-M and it is designed for connection to a conventional zone of point type fire detectors that may include any mix of detection technologies. The 601FEx-M is an intrinsically safe version intended for use in hazardous atmospheres and must be connected via a suitable isolator or shunt diode safety barrier in a certified Intrinsically Safe system. Ordering Information: Stockcode Description 516.600.007 601F-M Conventional Flame Detector 601FEx-M Conventional Flame Detector Intrinsically Safe 5B 5" Universal Base MUBEx Base For 600/800Ex MTL5061 2 Channel Galvanic Isolator DX170 MTL5/7000 Enclosure T110 IR Test Source T110 Test Source Adapter 516.600.067 517.050.017 517.050.610 517.001.244 517.001.247 592.001.012 592.001.018 Fire Detection PSF132UM.qxd 08/04/2004 09:00 Page 2 Mechanical Detector Material: Dimensions: Weight: - 601F-M - 601FEx-M Environmental FR110 ‘BAYBLEND’ 108mm x 21.2mm 74g 108g Operating temperature: Operation below 0oC is not recommended unless steps are taken to eliminate condensation and hence ice formation on the detector. Electrical Supply Voltage: Quiescent current: Alarm current: Storage Temperature: Relative Humidity: 601F-M 18 – 32Vdc 601FEx-M 18 – 28 Vdc Typical 300 micro Amp 8-30 mA Range: 28V 93mA 650mW 0 0 Field of View: 0.1m2 n-heptane at 20m 0.4m2 n-heptane at 50m 100o Mounting Base Hazardous Area ATEX code: -40oC to +80oC 90% RH continuous (noncondensing) and up to 99% RH intermittent (non-condensing) Performance Intrinsic Safety Rating Maximum Voltage for Safety (Ui): Maximum Current for Safety (Ii): Maximum Power Input (Pi): Equivalent Inductance (Li): Equivalent Capacitance (Ci): -20oC to +70oC II 1 G EEx ia IIC T4 50o 50o L -VE IN/OUT L1 +VE IN L2 +VE OUT R Remote LED Drive -VE 12m Note 2: Diagram not to scale 19m 0.2m2 Connections: 8m 9.5m 0.1m2 5” Universal Base Note 1: When the risk is a hot vibrating body the detector should be mounted securely using a suitably fabricated bracket at an angle or on a vertical surface to view the risk. 4m 0.05m2 5B: 28.5m 16m 0.4m2 Approx Flame Area 38m The right is reserved to modify or withdraw any product or service without notice Technical Information Sheet PSF132UM Issue 1 www.tycosafetyproducts-europe.com ©Tyco Safety Products 2003 DISTRIBUTOR FOR NORWAY Holta & Håland Safety AS