Energence® Rooftop Units
50 HZ
P R O D U C T S P E C I F I C AT I O N S
Bulletin No. 490152
January 2013
Supersedes November 2012
88 to 105 kW (25 to 30 Tons)
Net Cooling Capacity − 74.4 to 88.5 kW (254 000 to 302 000 Btuh)
Optional Electric Heat - 23 to 91.9 kW
MODEL NUMBER IDENTIFICATION
L c H 300 H 4 B S 1 M
Brand/Family
L = Energence®
Voltage
M = 380/420V-3 phase-50hz
Unit Type
C = Packaged Electric Cooling with optional Electric Heat
Major Design Sequence
H = 1st Generation
Nominal Cooling Capacity - kW
300 = 88 kW
360 = 105 kW
Cooling Efficiency
H = High Efficiency
Minor Design Sequence
1 = 1st Revision
2 = 2nd Revision
3 = 3rd Revision
Factory Installed Electric Heat
N = No Heat
J = 23 kW Electric Heat
K = 34.5 kW Electric Heat
L = 45.9 kW Electric Heat
P = 68.9 kW Electric Heat
S = 91.9 kW Electric Heat
Blower Type
B = Constant Air Volume (CAV) Belt Drive
Refrigerant Type
4 = R-410A
FEATURES AND BENEFITS
I
M
O
K
F
N
D
E
L
G
B
H
C
J
Lennox’ Energence® packaged rooftop unit product line was created to save energy with intelligence by offering some
of the highest energy efficiency ratings available with a powerful, easy to use unit controller.
This makes Energence rooftop units perfect for business owners looking for an Heating/Ventilation/Air Conditioning
(HVAC) product with the lowest total cost of ownership. Energence rooftop units feature:
• H
inged Access Panels - Provides quick access to components and protect panels and roof from damage during servicing.
• Isolated Compressor Compartment - Allows performance check during normal compressor operation without disrupting
airflow.
• Corrosion-Resistant Removable Drain Pan - End or bottom drain connection capability. Provides
application flexibility, durability and improved serviceability.
•
•
•
•
•
hermostatic Expansion Valves - Provides peak cooling performance across the entire application range.
T
Scroll Compressors - Standard on all units for reliable, long-term operation.
Lennox’ Environ™ Coil System - Smaller, lighter condenser coil.
Constant Air Volume (CAV) Blower - Allows constant air delivery.
Auto-Tensioner for Blower Belt - Factory option ensures blower is delivering the proper airflow for
comfort, while maximizing efficiency and belt life.
• MERV 13 (Minimum Efficiency Reporting Value) Filters - Available as factory or field option, provides an enhanced
level of indoor air quality (IAQ).
• Foil-Faced Insulation - Insulation on all internal surfaces that have contact with airflow helps minimize airborne fibers and
improve indoor air quality (IAQ).
Prodigy® Control System
Standard on every Energence rooftop unit, the new Prodigy® unit controller is the heart of
the Lennox® controls offering. The intuitive user interface makes setup, troubleshooting
and service easier than ever. Each unit tracks the runtime of every major component and
records the date and time when service or maintenance is performed.
SmartWire™ System
The SmartWire system simplifies field sensor or thermostat installation through advanced connectors that are keyed
and color-coded to help prevent miswiring. Not only is the wire coloring scheme standardized across all models, each
connection is intuitively labeled to make troubleshooting and servicing quick and easy.
Energence® Packaged Electric / Electric 88 to 105 kW - 50 hz / Page 2
FEATURES AND BENEFITS
Contents
Accessory Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Blower Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Electrical/Electric Heat Data . . . . . . . . . . . . . . . . . . . . . . . . 20
Electric Heat Capacities . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Features And Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Model Number Identification . . . . . . . . . . . . . . . . . . . . . . . . .1
Optional Conventional Temperature Control Systems . . . . . . . . . . . 22
Options / Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Outdoor Sound Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Prodigy® Control System . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Unit Clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Weight Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Performance/quality
Components bonded for grounding
to meet safety standards for
servicing required by Underwriters
Laboratories (UL) and the
International Electrotechnical
Commission (IEC).
Cooling performance is rated
at test conditions included in
Air-Conditioning, Heating and
Refrigeration (AHRI) Standard
340/360-2007 while operating at
rated voltage and air volumes.
International Organization for
Standardization (ISO) 9001
Registered Manufacturing Quality
System.
CE Mark Option
The CE mark has
been added to our
rooftop product line
as a configure to
order (CTO) option.
This optional construction allows
units to be sold into countries
requiring CE marking for rooftop
products.
CE marked units meet the
requirements of the Machinery
Directive 2006/42/EC, Low
Voltage Directive 73/23/EEC, EMC
Directive 89/336/EEC, and Gas
Directive 90/396/EEC. Declaration
of conformity certificates will be
provided for each CE marked unit
on demand.
Key features of this option over
and above standard product
features are:
• Touch-proof electrical
components meeting the
requirements of EN 60529.
Compressor Crankcase Heaters
Protects against refrigerant
migration that can occur during low
ambient operation.
C
Lennox’ Environ™ Coil System
Condenser
coil features
lightweight,
all aluminum
brazed fin
construction.
Constructed
of three
components: a flat extrusion tube,
fins in-between the flat extrusion
tube and two refrigerant manifolds.
Environ™ Coil System Features:
• I mproved heat transfer
performance due to high
primary surface area (flat
tubes) versus secondary
surface (fins).
• S
maller internal volume
(reduced refrigerant charge).
• B
ranch circuits over 0.5 kW load
have overcurrent protection.
• H
igh durability (all aluminum
construction).
• R
otary style/finger safe
disconnect switch with locking
handle prevents disconnect
door from being opened with
the power on. Padlock can be
applied to lock the disconnect
switch in the OFF position.
• Fewer brazed joints.
• C
ompact design (reduces unit
weight).
• Easy maintenance/cleaning.
Face split design.
• T
he factory wiring has been
redesigned for separation of
high and low voltage circuits.
Mounting brackets with rubber
inserts secure coil to unit providing
vibration dampening and corrosion
protection.
COOLING SYSTEM
Designed to maximize sensible
and latent cooling performance at
design conditions.
Evaporator Coil
System can operate from 18°C
to 52°C without any additional
controls.
R-410A Refrigerant
Non-chlorine
based, ozone
friendly, R-410A.
B Scroll Compressors
Scroll compressors on all models
for high performance, reliability and
quiet operation.
Angled design in cabinet helps
protect coil from possible contact
or hail damage.
Copper tube construction,
enhanced rippled-edge aluminum
fins, flared shoulder tubing
connections, silver-soldered
construction for improved heat
transfer. Factory leak tested. Cross
row circuiting with rifled tubing
optimizes both sensible and latent
cooling capacity. Low fin per inch
count minimizes air pressure drop.
Constant Air Volume (CAV) models
have face-split evaporator coils.
Resiliently mounted on rubber
grommets for quiet operation.
Energence® Packaged Electric / Electric 88 to 105 kW - 50 hz / Page 3
FEATURES AND BENEFITS
COOLING SYSTEM
(CONTINUED)
D Thermal Expansion Valves
Assures optimal performance
throughout the application range.
Removable element head.
E Filter/Driers
High capacity filter/drier protects
the system from dirt and moisture.
High Pressure Switches
Protects the compressors from
overload conditions such as
dirty condenser coils, blocked
refrigerant flow, or loss of outdoor
fan operation. Automatic reset.
Low Pressure Switches
Protects the compressors from low
pressure conditions such as low
refrigerant charge, or low/no airflow.
Condensate Drain Pan
Plastic, sloped drain pan.
Side drain connections.
Stainless steel drain pan available
as a factory installed option.
Freezestats
Protects the evaporator coil from
damaging ice build-up due to
conditions such as low/no airflow,
or low refrigerant charge.
REQUIRED SELECTIONS
Cooling Capacity
Specify nominal cooling capacity of
the unit.
OPTIONS/ACCESSORIES
Factory Installed
Discharge Air Temperature
Sensor
Sensor sends information to the
unit controller to cycle up to 2
stages of heating or 4 stages of
cooling to maintain the discharge
air setpoints for heating or cooling.
Optional for units with single zone
or bypass zoning control. Sensor
is shipped with the unit for remote
field installation in the supply duct.
Factory or Field Installed
Condensate Drain Trap
Field installed only, may be factory
enclosed to ship with unit.
Available in copper or Polyvinyl
chloride (PVC).
Drain Pan Overflow Switch
Monitors condensate level in
drain pan, shuts down unit if drain
becomes clogged.
Stainless Steel Drain Pan
Non-corrosive drain pan.
F Outdoor Coil Fan Motors
G BLOWER
A wide selection of supply air
blower options are available
to meet a variety of airflow
requirements.
Motor
Overload protected, equipped with
ball bearings.
Belt drive motors are offered on
all models and are available in
several different sizes to maximize
air performance.
Supply Air Blower
Forward curved blades, double
inlet, blower wheel is statically and
dynamically balanced. Belt drive
motors with adjustable pulley for
speed change.
Blower assembly slides out of unit
for servicing.
Grease fittings furnished.
REQUIRED SELECTIONS
Specify motor output and drive kit
number when base unit is ordered,
see Drive Kit Specifications tables.
Order one drive kit, see Drive Kit
Specifications Table.
OPTIONS/ACCESSORIES
Factory Installed
Blower Belt Auto-Tensioner
Thermal overload protected, totally
enclosed, permanently lubricated
ball bearings, shaft up, wire basket
mount.
Provides proper tension to belt
drive blower belt without the need
for regular adjustments. Maintains
airflow and proper performance.
Outdoor Coil Fans
Field Installed
Polyvinyl chloride (PVC) coated
fan guard furnished.
Energence® Packaged Electric / Electric 88 to 105 kW - 50 hz / Page 4
Supply Static Limit Switch
Field installed manual reset switch
for supply static high pressure
limit. Prevents exceeding pressure
limit in supply air duct. Optional
Mounting Kit includes tubing and
adaptors.
FEATURES AND BENEFITS
ELECTRICAL
All units include terminal block
and fuse block in power entry
junction box for single power entry
application.
REQUIRED SELECTIONS
Voltage Choice
Specify when ordering base unit.
OPTIONS/ACCESSORIES
Factory or Field Installed
H Electric Heat
Electric heat is CE marked.
Helix wound nichrome elements,
individual element limit controls,
wiring harness. Unit fuse block
is furnished as standard. See
Options / Accessories tables for
ordering information.
CABINET
I Construction
OPTIONS/ACCESSORIES
Factory Installed
Heavy-gauge steel panels and full
perimeter heavy-gauge galvanized
steel base rail provides structural
integrity for transportation,
handling, and installation.
Base rails have rigging holes.
Three sides of the base rail have
forklift slots.
Raised edges around duct and
power entry openings in the bottom
of the unit provide additional
protection against water entering
the building.
Airflow Choice
Units are available in downflow
(vertical) or horizontal return air
flow configuration.
Corrosion Protection
A completely flexible immersed
coating with an electrodeposited
dry film process (AST ElectroFin
E-Coat). Meets Mil Spec
MIL-P-53084, ASTM B117
Standard Method Salt Spray
Testing.
Indoor Corrosion Protection:
- Coated coil
- Painted blower housing
- Painted indoor base
Outdoor Corrosion Protection:
- Coated coil
- Painted outdoor base
Field Installed
Coil Guards
Horizontal air flow requires
Horizontal Roof Curb.
Painted, galvanized steel wire
guards to protect outdoor coil.
Horizontal Return Air Panel Kit
is also required if converting
a downflow configured unit to
horizontal air flow.
Not used with Hail Guards.
Power Entry
Electrical lines can be brought
through the unit base or through
horizontal access knock-outs.
Exterior Panels
Constructed of heavy-gauge,
galvanized steel with a two-layer
enamel paint finish.
Insulation
All panels adjacent to conditioned
air are fully insulated with nonhygroscopic fiberglass insulation.
Unit base is fully insulated. The
insulation also serves as an air
seal to the roof curb, eliminating
the need to add a seal during
installation.
Grille Guards
Protects the space between
outdoor coils and main cabinet.
Hail Guards
Constructed of heavy gauge steel,
painted to match cabinet, helps
protect outdoor coils from hail
damage.
Not used with Coil Guards.
Horizontal Return Air Panel Kit
Required for horizontal
applications with Horizontal Roof
Curb, contains panel with return
air opening for field replacement
of existing unit panel and panel to
cover bottom return air opening in
unit, see dimension drawings.
J Hinged Access Panels
Hinged tool-less access panels are
provided for the filter section, the
blower section and compressor/
controls section.
All hinged panels have seals and
quarter-turn latching handles to
provide a tight air and water seal.
Energence® Packaged Electric / Electric 88 to 105 kW - 50 hz / Page 5
FEATURES AND BENEFITS
INDOOR AIR QUALITY
K Air Filters
Disposable 51 mm filters furnished
as standard.
OPTIONS/ACCESSORIES
Factory Installed
Healthy Climate® UVC
Germicidal Light Kit
Factory or Field Installed
Blower Access
Healthy Climate High Efficiency
Air Filters
Supply air blower parts are located
near the access door for easy
servicing and adjustment.
®
Disposable MERV 8 or MERV 13
(Minimum Efficiency Reporting
Value based on ASHRAE 52.2)
efficiency 51 mm pleated filters.
Replacement Filter Media Kit
With Frame
Replaces existing pleated filter
media. Includes washable metal
mesh screen and metal frame with
clip for holding replaceable nonpleated filter.
Field Installed
Germicidal lamps emit ultra-violet
(UV-C) energy, which has been
proven to be effective in reducing
microbes such as viruses, bacteria,
yeasts, and molds. This process
either destroys the organism or
controls its ability to reproduce.
UV-C energy greatly reduces the
growth and proliferation of mold
and other bioaerosols (bacteria
and viruses) on illuminated
surfaces (particularly coil and drain
pan).
Lamps are field installed in the
blower/evaporator coil section.
All necessary hardware for
installation is included.
Lamps operate on 220V singlephase power supply. Step-down
transformer is furnished with lamps
when used with 380/420V rooftop
units. Alternatively, 220V power
supply may be used to directly
power the UVC ballast(s).
Indoor Air Quality (CO2) Sensors
Monitors CO2 levels, reports to
the Prodigy® Unit Controller, which
adjusts economizer dampers as
needed.
SERVICEABILITY
Designed to streamline general
maintenance and decrease
troubleshooting time.
Diagnostics
Prodigy Unit Controller diagnostic
scrolling text pinpoints problems,
minimizing troubleshooting time.
SmartWire™ System
Advanced wiring connectors are
keyed and color-coded to prevent
miswiring. Wire coloring scheme
is standardized across all models.
Each connection is intuitively
labeled to make troubleshooting
and servicing quick and easy.
Electrical Plugs
Positive connection electrical plugs
are used to connect common
accessories or maintenance parts
for easy removal or installation.
Toolless, Hinged Access Panels
Large access panels are hinged
and have quarter-turn, latching
handles for quick and easy access
to maintenance areas (filter,
compressor / controls / blower /
heat section).
Energence® Packaged Electric / Electric 88 to 105 kW - 50 hz / Page 6
Blower assembly slides out of unit
for servicing.
Thermal Expansion Valves
Thermal Expansion Valves are
located near the perimeter of the
unit for easier access.
Removable element head allows
change out of element and bulb
without removing the Thermal
Expansion Valves (TXV).
Coil Cleaning
Slab condenser coils provided for
easier cleaning.
Standard Components
A large number of common
maintenance parts are standard
throughout the entire range of
sizes reducing the need to carry
a lot of different parts to the job or
maintain in inventory.
Compressor Compartment
Compressors are located near
the perimeter of the unit for easier
access.
Compressors are isolated from the
condenser airflow allowing system
operation checks to be done
without changing the airflow across
the outdoor coils.
PRODIGY® CONTROL SYSTEM
L PRODIGY UNIT CONTROLLER
The Prodigy Unit Controller is a
microprocessor-based control
board that provides flexible control
of all unit functions.
Prodigy Unit Controller features:
Scrolling Display - Scrolls full text
instead of numerical codes.
Push Buttons - Simplified
navigation during setup and
diagnostics.
Guided Setup Procedure Ensures proper installation and
setup of the rooftop unit.
Profile setup - Copy key setpoints
between units with the same
configuration greatly reducing
setup time.
Universal Serial Bus (USB) Port
- Easily download and transfer unit
information via a USB
flash drive and also
interface with Lennox
Unit Controller
Software.
Self Test Mode Confirm proper component and
system operation.
Time Clock with Run-time
Information
Built-In Functions Include:
Blower Air Delivery Options
Adjustable Blower On/Off Delay
Built-in Control Parameter
Defaults
Compressor Time-Off Delay
DDC Compatible
Dirty Filter Switch Input
Discharge Air Temperature
Control
Display/Sensor Readout
Economizer Control Options See Economizer / Outdoor Air /
Exhaust Options.
Fresh Air Tempering
Extensive Unit Diagnostics Over 100 diagnostic and status
messages in English.
Exhaust Fan Control Modes Fresh air damper position.
Permanent Diagnostic Code
Storage
Field Changeable Control
Setpoints - Over 200 different
control setpoints.
Indoor Air Quality Input Demand Control Ventilation ready.
Low Ambient Controls - Cooling
operation down to -18°C.
Gas Valve Time Delay Between
First and Second Stage
Minimum Compressor Run Time
Network Capable - Can be daisy
chained to other units or controls.
Night Setback Mode
Return Air Temperature Limit
Control
Safety Switch Input - Allows
controller to respond to a external
safety switch trip.
Service Relay Output
Smoke Alarm Mode - Four choices.
Staging - Up to 2 heat / 2 cool with
standard Prodigy unit controller.
Up to 4 heat / 4 cool with add-on
control board.
“Strike Three” Protection
Gas Reheat Control Simultaneous heating and cooling
operation for controlling humidity
for process air applications such as
supermarkets.
Thermostat Bounce Delay
Warm Up Mode Delay
LED Indicators
PC Interface - For use with PC
with optional Unit Controller
software.
Zone Sensor Operation - Controls
zone temperature.
CONTROLS OPTIONS
Factory or Field Installed
OPTIONS / ACCESSORIES
Factory or Field Installed
Field Installed
Blower Proving Switch
Monitors blower operation, shuts
down unit if blower fails.
Dirty Filter Switch
Senses static pressure increase
indicating dirty filter condition.
Fresh Air Tempering
Used in applications with high
outside air requirements. The
controller energizes the first stage
heat as needed to maintain a
minimum supply air temperature
for comfort, regardless of the
thermostat demand. When ordered
as a factory option, the sensor
ships with the unit but must be field
installed.
Smoke Detector
Photoelectric type, installed in
supply air section, return air
section or both sections. Available
with power board and single
sensor (supply or return) or power
board and two sensors (supply and
return). Power board located in unit
control compartment.
Interoperability via BACnet® or
LonTalk® Protocols
Communication compatible with
third-party automation systems that
support the BACnet Application
Specific Controller device
profile, LonMark® Space Comfort
Controller functional profile, or
LonMark Discharge Air Controller
functional profile.
Commercial Control Systems
Aftermarket DDC
Novar® Unit Controller and options.
Thermostats
Control system and thermostat
options. Aftermarket unit controller
options.
Humidity Sensor Kit
Humidity sensor required
with Supermarket reheat field
selectable option.
NOTE - Prodigy Control System features
shown vary with the type of rooftop unit
the control is installed in.
NOTE - See separate Prodigy Control
System Product Specifications Bulletin
for additional information.
Energence® Packaged Electric / Electric 88 to 105 kW - 50 hz / Page 7
OPTIONS / ACCESSORIES
M ECONOMIZER/EXHAUST
OPTIONS
Factory or Field Installed
Economizer - Downflow or
Horizontal With Air Hood
Parallel gear-driven action return
air and outdoor air dampers,
plug-in connections to unit, nylon
bearings, neoprene seals, 24volt, fully-modulating, spring
return motor, adjustable minimum
damper position. Outdoor air hoods
for economizer and downflow
barometric relief dampers furnished.
Choice of economizer control
options:
1. Differential Sensible Control
Factory setting. Uses outdoor
air and return air sensors that
are furnished with the unit.
The Prodigy Unit Controller
compares outdoor air with
return air. When the outdoor
air is below the configured
setpoint and cooler than return
air, the controller enables the
economizer.
NOTE - Differential Sensible
Control can be configured in the
field to provide Offset Differential
Sensible Control or Single
Sensible Control.
In Offset Differential Sensible
Control mode, the economizer
is enabled if the temperature
differential (offset) between
outdoor air and return air reaches
the configured setpoint.
In Single Sensible Control mode,
the economizer is enabled when
outdoor air temperature falls below
the configured setpoint.
2. Global Control
The unit controller
communicates with a DDC
system with one global sensor
(enthalpy or sensible) to
determine whether outside air
is suitable for free cooling on all
units connected to the control
system. Sensor must be field
provided.
3. Single Enthalpy Control
Outdoor air enthalpy sensor
enables economizer if the
outdoor enthalpy is less than the
setpoint of the board.
4. Differential Enthalpy Control
Two solid-state enthalpy sensors
allow the economizer control to
select between outdoor air or
return air, whichever has lower
enthalpy.
Factory or Field Installed
Downflow Barometric Relief
Dampers
N Allows relief of excess air,
aluminum blade dampers prevent
blow back and outdoor air
infiltration during off cycle, bird
screen furnished.
Hood for downflow barometric
relief dampers is factory installed
when dampers are factory installed
with economizer. Hood is furnished
with dampers when ordered for
field installation.
O Standard Static Power Exhaust
Fans
Three 0.25 kW motors with
508 mm diameter, five-blade
propeller type fans with a total
power input of 1125 W and a total
air volume of 6040 L/s at 0 Pa.
Installs internal to unit for downflow
applications only with economizer
option, provides exhaust air
pressure relief, interlocked to
run when return air dampers are
closed and supply air blower is
operating, fan runs when outdoor
air dampers are 50% open
(adjustable), motor is overload
protected, steel cabinet and hood
painted to match unit, requires
optional Downflow Economizer
Barometric Relief Dampers. See
Standard Static Power Exhaust
Blower Tables.
Energence® Packaged Electric / Electric 88 to 105 kW - 50 hz / Page 8
Field Installed
Horizontal Barometric Relief
Dampers
For use when unit is configured for
horizontal applications requiring an
economizer.
Allows relief of excess air.
Aluminum blade dampers prevent
blow back and outdoor air
infiltration during off cycle.
Field installed in return air duct.
Bird screen and hood furnished.
OUTDOOR AIR OPTIONS
Factory or Field Installed
Outdoor Air Damper - Downflow
or Horizontal With Air Hood
Linked mechanical dampers, 0 to
25% (fixed) outdoor air adjustable,
installs in unit. Includes outdoor air
hood.
Automatic model features fully
modulating spring return damper
motor with plug-in connection.
Manual model features parallel
blade, gear-driven dampers with
adjustable fixed position.
Minimum mixed air temperature in
heating mode is -1°C. Maximum
mixed air temperature in cooling
mode is 32°C.
OPTIONS / ACCESSORIES
ROOF CURBS
Nailer strip furnished, mates to
unit, shipped knocked down.
CEILING DIFFUSERS
Ceiling Diffusers
(Flush or Step-Down)
Downflow
Aluminum grilles, large center
grille, insulated diffuser box with
flanges, hanging rings furnished,
interior transition (even air flow),
internally sealed (prevents
recirculation), adapts to T-bar
ceiling grids or plaster ceilings.
Standard Curbs - Curb corners
fasten together with furnished
hardware.
Available in 356 mm and 610 mm
heights.
Horizontal
Converts unit from downflow to
horizontal (side) air flow, return air
is on unit, supply air is on curb, see
dimension drawings.
Available in 940 mm and 1041 mm
heights.
Transitions (Supply and Return)
Used with diffusers, installs
in roof curb, galvanized steel
construction, flanges furnished for
duct connection to diffusers, fully
insulated.
Requires Horizontal Return Air
Panel Kit.
Optional Insulation Kit is available
to help prevent sweating.
Energence® Packaged Electric / Electric 88 to 105 kW - 50 hz / Page 9
OPTIONS / ACCESSORIES
Model
Number
Item Description
Catalog
Number
Unit Model No
300
360
Factory
O
O
76M26
OX
OX
ce mark
CE Marked Unit
COOLING SYSTEM
Condensate Drain Trap
Polyvinyl chloride (PVC) - C1TRAP20AD2
76W27
OX
OX
Factory
O
O
E1SNSR71AD1
68W88
OX
OX
High
Factory
O
O
R-410A
Factory
O
O
Copper - C1TRAP10AD2
Corrosion Protection
Drain Pan Overflow Switch
Efficiency
Refrigerant Type
Plastic Condensate Drain Pan
Factory
O
O
C1DPAN10D-1-
83W42
OX
OX
Belt Drive - 3.7 kW
Factory
O
O
Belt Drive - 5.6 kW
Factory
O
O
Belt Drive - 7.5 kW
Factory
O
O
Kit #1 615-745 rev/min
Factory
O
O
Kit #2 725-870 rev/min
Factory
O
O
Kit #3 595-730 rev/min
Factory
O
O
Kit #4 640-805 rev/min
Factory
O
O
Kit #5 550-675 rev/min
Factory
O
O
Kit #6 640-805 rev/min
Factory
O
O
Kit #7 475-600 rev/min
Factory
O
O
Kit #8 400-525 rev/min
Factory
O
O
Kit #9 340-445 rev/min
Factory
O
O
Blower Belt Auto-Tensioner
Factory
O
O
Coil Guards
C1GARD29121
84W63
X
X
Grille Guards
C1GARD39D-1-
86K30
X
X
Hail Guards
C1GARD19121
84W62
X
X
38K48
X
X
C1SNSR35FF1
53W65
OX
OX
Prodigy Control System - BACnet Module - C0CTRL60AE1L
59W51
OX
OX
Prodigy Control System - LonTalk Module - C0CTRL65FF1
54W27
OX
OX
Novar® ETM-2051 Unit Controller - E0CTRL30C1
64W74
OX
OX
Novar LSE
Factory
O
O
E1SNSR55C-1
53W68
OX
OX
Factory
O
O
Stainless Steel Condensate Drain Pan
BLOWER - SUPPLY AIR
Motors
Drive Kits
See Blower Data Tables for usage and
selection
CABINET
Horizontal Return Air Panel Kit
CONTROLS
Blower Proving Switch
®
®
®
®
®
Dirty Filter Switch
Discharge Air Temperature Sensor
C1SNSR75AD1
58W63
OX
OX
Smoke Detector - Supply or Return (Power board and one sensor)
C1SNSR44C-1
83W40
OX
OX
Smoke Detector - Supply and Return (Power board and two sensors)
C1SNSR43C-1
83W41
OX
OX
Supply Static Limit Switch
C0SNSR11AE1
79M80
X
X
Supply Static Limit Switch - Mounting Kit
C0SNSR12AE1
79M81
X
X
Supply Static Transducer
C0SNSR20AE1
78M19
X
X
Fresh Air Tempering
NOTE - Catalog and model numbers shown are for ordering field installed accessories.
OX - Configure To Order (Factory Installed) or Field Installed
O = Configure To Order (Factory Installed)
X = Field Installed
Energence® Packaged Electric / Electric 88 to 105 kW - 50 hz / Page 10
OPTIONS / ACCESSORIES
Model
Number
Item Description
Catalog
Number
Unit Model No
300
360
INDOOR AIR QUALITY
Air Filters
MERV 8 - C1FLTR15D-1-
54W21
OX
OX
MERV 13 - C1FLTR40D-1-
52W39
OX
OX
C1FLTR30D-1-
44N60
X
X
Sensor - Wall-mount, off-white plastic cover with LCD display
C0SNSR50AE1L
77N39
X
X
Sensor - Wall-mount, off-white plastic cover, no display
C0SNSR52AE1L
87N53
X
X
Sensor - Black plastic case with LCD display, rated for plenum mounting
C0SNSR51AE1L
87N52
X
X
C0MISC19AE1
87N54
X
X
CO2 Sensor Duct Mounting Kit - for downflow applications
C0MISC19AE1-
85L43
X
X
Aspiration Box - for duct mounting non-plenum rated CO2 sensors
(87N53 or 77N39)
C0MISC16AE1-
90N43
X
X
Factory
O
O
380/420V - 3 phase
Factory
O
O
23 kW
380/420V-3ph - C1EH0230C21M
67W98
OX
OX
34.5 kW
380/420V-3ph - C1EH0345C21M
68W00
OX
OX
45.9 kW
380/420V-3ph - C1EH0459C21M
68W02
OX
OX
68.9 kW
380/420V-3ph - C1EH0689C-1M
68W03
OX
OX
91.9 kW
380/420V-3ph - E1EH0900D-1M
74W01
OX
OX
E1ECON15D-1
74W43
OX
OX
Order 2 - C1SNSR64FF1
53W64
OX
OX
Sensor is Furnished
Factory
O
O
C1SNSR64FF1
53W64
OX
OX
Sensor Field Provided
Factory
O
O
Sensor is Furnished
Factory
O
O
Downflow Barometric Relief Dampers - (Hood Furnished)
E1DAMP60D-1
76W17
OX
OX
Horizontal Barometric Relief Dampers - (Hood Furnished)
LAGEDH30/36
33K78
OX
OX
Outdoor Air Dampers - Motorized - (Hood Furnished)
E1DAMP25D-1-
74W44
OX
OX
Outdoor Air Dampers - Manual - (Hood Furnished)
E1DAMO15D-1-
74W45
OX
OX
Healthy Climate High Efficiency Air Filters
508 x 508 x 51 mm - order 12 per unit
Replaceable Media Filter with Metal Mesh Frame (includes Non-Pleated
Filter Media) 508 x 508 x 51 mm - order 12 per unit
Indoor Air Quality (CO2) Sensors
Sensor - Wall-mount, black plastic case, no display, rated for plenum
mounting
UVC Germicidal Light Kit
1
Healthy Climate® UVC Light Kit (220V-1ph)
ELECTRICAL
Voltage 50 hz with neutral (No neutral on CE marked models)
ELECTRIC HEAT
ECONOMIZER
Economizer
Economizer - (Hood Furnished)
Economizer Controls
Differential Enthalpy
Sensible Control
Single Enthalpy
Global, Enthalpy
Differential Sensible
Barometric Relief
OUTDOOR AIR
1
Lamps operate on 220V, single phase power supply. Step-down transformer is furnished with lamps when used with 380/420V rooftop units.
NOTE - Catalog and model numbers shown are for ordering field installed accessories.
OX - Configure To Order (Factory Installed) or Field Installed
O = Configure To Order (Factory Installed)
X = Field Installed
Energence® Packaged Electric / Electric 88 to 105 kW - 50 hz / Page 11
OPTIONS / ACCESSORIES
Model
Number
Item Description
Catalog
Number
Unit Model No
300
360
POWER EXHAUST
380/420V - E1PWRE40D-1M
74W24
OX
OX
356 mm height
LARMF18/36-14
16K87
X
X
610 mm height
LARMF18/36-24
16K88
X
X
Standard Static
ROOF CURBS - DOWNFLOW
Standard Curbs
ROOF CURBS - HORIZONTAL (REQUIRES HORIZONTAL AIR PANEL KIT)
Standard Curbs
762 mm height - slab applications
LARMFH30/36-30
33K79
X
X
1041 mm height - rooftop applications
LARMFH30/36-41
38K54
X
X
38K48
X
X
for LARMFH30/36-30
73K33
X
X
for LARMFH30/36-41
73K35
X
X
LARTD30/36
35K25
X
X
LAFD30/36
35K24
X
X
LASRT30/36
33K80
X
X
Horizontal Return Air Panel Kit (Required)
Insulation Kit For Standard Horizontal Curbs
CEILING DIFFUSERS
Step-Down - Order one
Flush - Order one
Transitions (Supply and Return) - Order one
NOTE - Catalog and model numbers shown are for ordering field installed accessories.
OX - Configure To Order (Factory Installed) or Field Installed
O = Configure To Order (Factory Installed)
X = Field Installed
Energence® Packaged Electric / Electric 88 to 105 kW - 50 hz / Page 12
SPECIFICATIONS
General
Data
Nominal kW (Tons)
Model Number
Efficiency Type
Blower Type
Cooling
Gross Cooling Capacity - kW (Btuh)
1
Performance
Net Cooling Capacity - kW (Btuh)
AHRI Rated Air Flow - L/s (cfm)
Total Unit Power - kW
1
EER (Btuh/Watt)
2
IEER (Btuh/Watt)
Refrigerant Type
Refrigerant
Circuit 1
Charge
Circuit 2
Circuit 3
Circuit 4
Electric Heat Available - See page 19
Compressor Type (number)
Outdoor
Net face area - m2 (sq. ft.) total
Coils
Number of rows
Fins per m (Fins per inch)
Outdoor Coil
Motor - (No.) W (hp)
Fans
Motor rev/min
Total Motor watts
Diameter - mm (in.)
Number of blades
Total Air volume - L/s (cfm)
Indoor Coils
Net face area - m2 (sq. ft.) total
Tube diameter - mm (in.)
Number of rows
Fins per m ( Fins per inch)
Drain connection - No. and size
Expansion device type
3
Indoor
Nominal motor output
Blower
Maximum usable motor output
and
Motor - Drive kit
Kit
Selection
88 (25)
LCH300H4B
High
Constant Air Volume (CAV)
76.8 (262 000)
74.4 (254 000)
3825 (8100)
21.1
12.0
12.5
R-410A
4.2 kg (9 lbs. 4 oz.)
4.1 kg (9 lbs. 0 oz.)
4.0 kg (8 lbs. 12 oz.)
3.9 kg (8 lbs. 8 oz.)
105 (30)
LCH360H4B
High
Constant Air Volume (CAV)
92.0 (314 000)
88.5 (302 000)
4530 (9600)
27.5
11.0
11.5
R-410A
4.1 kg (9 lbs. 0 oz.)
3.6 kg (8 lbs. 0 oz.)
4.1 kg (9 lbs. 0 oz.)
3.4 kg (7 lbs. 8 oz.)
Scroll (4)
Scroll (4)
6.3 (68.3)
6.3 (68.3)
1
1
906 (23)
906 (23)
(6) 249 (1/3)
(6) 249 (1/3)
900
900
1775
1775
(6) 610 (24)
(6) 610 (24)
3
3
8450 (17 900)
8450 (17 900)
2.9 (31.40)
2.9 (31.40)
9.5 (3/8)
9.5 (3/8)
4
4
551 (14)
(551) 14
(1) 1 in. NPT
(1) 1 in. NPT
Balance port Thermostatic Expansion Valve (TXV), removable head
3.7 kW (5 hp) - 5.6 kW (7.5 hp) - 7.5 kW (10 hp)
4.3 kW (5.75 hp) - 6.4 kW (8.63 hp) - 8.6 kW (11.5 hp)
3.7 kW (5 hp)
Kit 5 - 550-675 rev/min
Kit 6 - 640-805 rev/min
Kit 7 - 475-600 rev/min
Kit 8 - 400-525 rev/min
Kit 9 - 340-445 rev/min
5.6 kW (7.5 hp)
Kit 3 - 595-730 rev/min
Kit 4 - 640-805 rev/min
Blower wheel nominal diameter and width - mm (in.)
Type of filter
Number and size - mm (in.)
Electrical characteristics
Filters
7.5 kW (10 hp)
Kit 1 - 615-745 rev/min
Kit 2 - 725-870 rev/min
(2) 457 x 381 (18 x 15)
Fiberglass, disposable
(12) 508 x 508 x 51 (20 x 20 x 2)
380/420V - 50 hertz - 3 phase with neutral
(No neutral on CE marked models)
NOTE - Net capacity includes evaporator blower motor heat deduction. Gross capacity does not include evaporator blower motor heat deduction.
1 Tested at conditions based on AHRI Standard 340/360; 35°C (95°F) outdoor air temperature and 27°C (80°F) db/19°C (67°F) wb entering evaporator air; minimum
external duct static pressure while operating at rated voltage and air volumes.
2
Integrated Energy Efficiency Ratio tested at conditions included in AHRI Standard 340/360 while operating at rated voltage and air volumes.
3
Using total air volume and system static pressure requirements determine from blower performance tables rev/min and motor output required. Maximum usable output
of motors furnished are shown. See Belt Drive Specification Table for maximum usable motor output. If motors of comparable output are used, be sure to keep within
the service factor limitations outlined on the motor nameplate.
Energence® Packaged Electric / Electric 88 to 105 kW - 50 hz / Page 13
RATINGS
NOTE − For Temperatures and Capacities not shown in tables, see bulletin − Cooling Unit Rating Table Correction Factor Data in Miscellaneous Engineering Data section.
88 kW - LCH300H4 (1ST STAGE)
Outdoor Air Temperature Entering Outdoor Coil
Entering Total
Wet
Air
Bulb Volume Total
Cool
TemperCap.
ature
17.2°C
19.4°C
21.7°C
18.3°C
23.9°C
Comp. Sensible To Total
Ratio (S/T)
Motor
Input
Dry Bulb
29.4°C
Total
Cool
Cap.
Comp.
Motor
Input
Sensible To Total
Ratio (S/T)
35°C
Comp. Sensible To Total
Ratio (S/T)
Motor
Input
Dry Bulb
Total
Cool
Cap.
Comp.
Motor
Input
Sensible To Total
Ratio (S/T)
Dry Bulb
Total
Cool
Cap.
L/s
kW
kW
24°C 27°C 29°C
kW
kW
24°C 27°C 29°C
kW
kW
24°C 27°C 29°C
kW
kW
24°C
27°C
29°C
3776
43.1
6.21
0.74
0.87
0.99
41.1
6.92
0.74
0.88
1
39
7.72
0.75
0.9
1
36.9
8.63
0.76
0.92
1
4719
45.2
6.31
0.79
0.95
1
43.2
7.01
0.79
0.96
1
41.1
7.81
0.81
0.98
1
39
8.73
0.83
1
1
5663
47.1
6.4
0.84
1
1
45.3
7.11
0.85
1
1
43.2
7.91
0.87
1
1
41.2
8.83
0.89
1
1
3776
45.7
6.33
0.58
0.71
0.84
43.7
7.04
0.58
0.72
0.85
41.6
7.83
0.58
0.73
0.87
39.4
8.75
0.58
0.74
0.89
4719
47.9
6.43
0.61
0.77
0.92
45.7
7.13
0.62
0.78
0.93
43.5
7.92
0.62
0.79
0.95
41.2
8.83
0.63
0.8
0.97
5663
49.4
6.51
0.65
0.82
0.98
47.2
7.2
0.65
0.83
0.99
45
7.99
0.67
0.85
1
42.6
8.89
0.66
0.87
1
3776
48.8
6.47
0.44
0.57
0.69
46.7
7.18
0.44
0.57
0.7
44.5
7.97
0.43
0.57
0.71
42.2
8.87
0.43
0.57
0.72
4719
50.9
6.58
0.45
0.6
0.75
48.7
7.28
0.45
0.61
0.76
46.5
8.06
0.44
0.61
0.77
44
8.97
0.44
0.62
0.78
5663
52.4
6.66
0.46
0.64
0.8
50.2
7.35
0.46
0.64
0.82
47.9
8.14
0.46
0.66
0.83
45.3
9.03
0.46
0.66
0.85
Dry Bulb
88 kW - LCH300H4 (2ND STAGE)
Outdoor Air Temperature Entering Outdoor Coil
Entering Total
Wet
Air
Bulb Volume Total
Cool
TemperCap.
ature
17.2°C
19.4°C
21.7°C
26.7°C
35°C
Comp. Sensible To Total
Ratio (S/T)
Motor
Input
Dry Bulb
43.3°C
Total
Cool
Cap.
Comp.
Motor
Input
Sensible To Total
Ratio (S/T)
Dry Bulb
Total
Cool
Cap.
24°C 27°C 29°C
kW
kW
24°C 27°C 29°C
kW
kW
21.7°C
Sensible To Total
Ratio (S/T)
Total
Cool
Cap.
Comp.
Motor
Input
24°C 27°C 29°C
kW
kW
24°C
27°C
29°C
Dry Bulb
kW
kW
3776
77.6
14.59
0.76
0.91
1
71.7
17.27
0.77
0.93
1
64.9
20.63
0.79
0.97
1
56.9
24.8
0.83
1
1
4719
81.6
14.79
0.82
0.98
1
75.6
17.46
0.84
1
1
69.3
20.84
0.87
1
1
61.5
25.02
0.92
1
1
5663
85.8
14.99
0.87
1
1
79.9
17.68
0.9
1
1
73.2
21.02
0.94
1
1
64.8
25.16
0.99
1
1
3776
82.9
14.85
0.59
0.74
0.88
76.7
17.51
0.59
0.75
0.9
69.5
20.84
0.6
0.77
0.93
60.6
24.95
0.61
0.81
0.98
4719
86.5
15.03
0.63
0.8
0.96
80.1
17.68
0.63
0.82
0.98
72.7
20.99
0.65
0.85
1
63.4
25.1
0.67
0.9
1
5663
89.4
15.17
0.67
0.86
1
82.6
17.8
0.68
0.88
1
75
21.12
0.7
0.92
1
65.4
25.19
0.73
0.97
1
3776
88.3
15.12
0.44
0.58
0.72
81.9
17.77
0.43
0.58
0.73
74.7
21.1
0.42
0.59
0.75
65.3
25.2
0.41
0.6
0.78
4719
92.2
15.32
0.45
0.62
0.78
85.4
17.95
0.45
0.63
0.8
77.7
21.26
0.44
0.64
0.83
67.8
25.32
0.44
0.66
0.87
5663
94.8
15.46
0.47
0.66
0.84
87.9
18.08
0.47
0.68
0.86
79.9
21.37
0.47
0.69
0.9
69.8
25.44
0.47
0.73
0.95
Entering Total
Wet
Air
Bulb Volume Total
Cool
TemperCap.
ature
19.4°C
Comp. Sensible To Total
Ratio (S/T)
Motor
Input
Dry Bulb
L/s
Outdoor Air Temperature Entering Outdoor Coil
17.2°C
51.7°C
48°C
50°C
Comp. Sensible To Total
Ratio (S/T)
Motor
Input
Dry Bulb
24°C 27°C 29°C
Total
Cool
Cap.
Comp.
Motor
Input
Sensible To Total
Ratio (S/T)
kW
kW
24°C 27°C 29°C
Dry Bulb
L/s
kW
kW
3776
60.4
22870
.81
.99
1.00
58.4
23890
.82
1.00
1.00
4719
65.1
23.09
0.89
1.00
1.00
63.1
24.10
0.91
1.00
1.00
5663
68.6
23.24
0.97
1.00
1.00
66.6
24.27
0.98
1.00
1.00
3776
64.7
23.05
0.60
0.79
0.96
62.5
24.08
0.61
0.80
0.97
4719
67.6
23.17
0.65
0.87
1.00
65.3
24.20
0.66
0.89
1.00
5663
69.8
23.29
0.71
0.95
1.00
67.5
24.31
0.72
0.96
1.00
3776
69.6
23.27
0.41
0.60
0.77
67.2
24.29
0.41
0.60
0.78
4719
72.4
23.43
0.44
0.65
0.85
69.9
24.42
0.44
0.66
0.86
5663
74.4
23.54
0.46
0.71
0.93
72.0
24.55
0.46
0.72
0.94
Energence® Packaged Electric / Electric 88 to 105 kW - 50 hz / Page 14
RATINGS
NOTE − For Temperatures and Capacities not shown in tables, see bulletin − Cooling Unit Rating Table Correction Factor Data in Miscellaneous Engineering Data section.
105 kW - LCH360H4 (1ST STAGE)
Outdoor Air Temperature Entering Outdoor Coil
Entering Total
Wet
Air
Bulb Volume Total
Cool
TemperCap.
ature
17.2°C
19.4°C
21.7°C
18.3°C
23.9°C
Comp. Sensible To Total
Ratio (S/T)
Motor
Input
Dry Bulb
29.4°C
Total
Cool
Cap.
Comp.
Motor
Input
Sensible To Total
Ratio (S/T)
Dry Bulb
Total
Cool
Cap.
L/s
kW
kW
24°C 27°C 29°C
kW
kW
24°C 27°C 29°C
kW
4455
51.5
8.07
0.73
0.86
0.99
49.2
8.94
0.73
0.88
1
5569
54
8.2
0.78
0.94
1
51.5
9.06
0.79
0.96
1
6683
56
8.31
0.83
1
1
53.7
9.18
0.85
1
4455
54.5
8.23
0.57
0.71
0.83
52.1
9.09
0.58
5569
56.8
8.35
0.61
0.76
0.91
54.3
9.21
6683
58.5
8.44
0.64
0.82
0.98
56
9.3
4455
57.9
8.41
0.44
0.56
0.69
55.4
5569
60.3
8.54
0.45
0.6
0.75
6683
62
8.64
0.46
0.64
0.8
35°C
Comp. Sensible To Total
Ratio (S/T)
Motor
Input
Dry Bulb
Total
Cool
Cap.
Comp.
Motor
Input
Sensible To Total
Ratio (S/T)
Dry Bulb
kW
24°C 27°C 29°C
kW
kW
24°C
27°C
29°C
46.9
9.92
0.74
0.89
1
44.6
11.06
0.75
0.91
1
49.2
10.04
0.8
0.98
1
46.8
11.18
0.81
0.99
1
1
51.5
10.16
0.86
1
1
49.1
11.32
0.88
1
1
0.71
0.85
49.7
10.07
0.58
0.72
0.86
47.2
11.21
0.58
0.73
0.88
0.61
0.77
0.93
51.8
10.18
0.62
0.78
0.95
49.2
11.32
0.62
0.8
0.96
0.65
0.83
0.99
53.4
10.29
0.65
0.85
1
50.8
11.42
0.66
0.86
1
9.27
0.43
0.57
0.69
52.9
10.25
0.43
0.57
0.7
50.3
11.39
0.42
0.57
0.71
57.6
9.4
0.45
0.6
0.75
55.1
10.38
0.44
0.61
0.76
52.4
11.51
0.44
0.61
0.77
59.2
9.49
0.46
0.64
0.81
56.6
10.46
0.46
0.64
0.83
53.9
11.6
0.46
0.66
0.84
105 kW - LCH360H4 (2ND STAGE)
Outdoor Air Temperature Entering Outdoor Coil
Entering Total
Wet
Air
Bulb Volume Total
Cool
TemperCap.
ature
L/s
17.2°C
19.4°C
21.7°C
26.7°C
35°C
Comp. Sensible To Total
Ratio (S/T)
Motor
Input
Dry Bulb
43.3°C
Total
Cool
Cap.
Comp.
Motor
Input
Sensible To Total
Ratio (S/T)
Dry Bulb
Total
Cool
Cap.
24°C 27°C 29°C
kW
kW
24°C 27°C 29°C
kW
kW
51.7°C
Comp. Sensible To Total
Ratio (S/T)
Motor
Input
Dry Bulb
Sensible To Total
Ratio (S/T)
Total
Cool
Cap.
Comp.
Motor
Input
24°C 27°C 29°C
kW
kW
24°C
27°C
29°C
Dry Bulb
kW
kW
4455
94
18.85
0.75
0.9
1
86.8
22.11
0.76
0.92
1
78.7
26.17
0.78
0.96
1
68.6
31.08
0.82
1
1
5569
98.4
19.09
0.81
0.97
1
91.1
22.35
0.83
1
1
83.3
26.45
0.86
1
1
73.7
31.43
0.91
1
1
6683
102.7
19.33
0.87
1
1
95.6
22.63
0.89
1
1
87.7
26.73
0.93
1
1
77.2
31.69
0.98
1
1
4455
99.9
19.17
0.58
0.73
0.87
92.3
22.44
0.58
0.74
0.89
83.8
26.48
0.59
0.76
0.93
72.8
31.38
0.6
0.8
0.98
5569
104
19.41
0.62
0.79
0.95
96
22.66
0.63
0.81
0.98
87.2
26.7
0.64
0.84
1
75.9
31.6
0.66
0.89
1
6683
107.1
19.58
0.66
0.85
1
98.9
22.83
0.67
0.88
1
89.7
26.85
0.68
0.91
1
78.1
31.76
0.72
0.97
1
4455
105.9
19.51
0.43
0.57
0.71
98
22.77
0.43
0.57
0.72
89.4
26.84
0.42
0.59
0.74
77.9
31.73
0.41
0.6
0.78
5569
110.2
19.77
0.45
0.62
0.77
102
23.01
0.44
0.62
0.79
92.8
27.05
0.44
0.63
0.82
80.5
31.93
0.44
0.66
0.87
6683
113.2
19.95
0.46
0.65
0.83
104.8
23.19
0.46
0.67
0.86
95.1
27.22
0.46
0.68
0.89
82.7
32.09
0.46
0.72
0.95
Outdoor Air Temperature Entering Outdoor Coil
Entering Total
Wet
Air
Bulb Volume Total
Cool
TemperCap.
ature
17.2°C
19.4°C
21.7°C
48°C
50°C
Comp. Sensible To Total
Ratio (S/T)
Motor
Input
Dry Bulb
Total
Cool
Cap.
Comp.
Motor
Input
Sensible To Total
Ratio (S/T)
24°C 27°C 29°C
kW
kW
24°C 27°C 29°C
Dry Bulb
L/s
kW
kW
4455
73.2
28.80
0.80
0.98
1
70.7
29.99
0.81
0.99
1
5569
78.2
29.13
0.88
0\1
1
75.8
30.34
0.89
1
1
6683
82.0
29.38
0.96
1
1
79.5
30.59
0.97
1
1
4455
77.9
29.10
0.60
0.78
0.95
75.2
30.30
0.60
0.79
0.97
5569
81.0
29.32
0.65
0.86
1
78.2
30.50
0.65
0.87
1
6683
83.4
29.48
0.70
0.94
1
80.5
30.69
0.71
0.95
1
4455
83.1
29.45
0.41
0.59
0.76
80.4
30.67
0.41
0.59
0.77
5569
86.4
29.69
0.44
0.65
0.84
83.3
30.90
0.44
0.65
0.85
6683
88.5
29.82
0.46
0.70
0.92
85.5
31.03
0.46
0.71
0.94
Energence® Packaged Electric / Electric 88 to 105 kW - 50 hz / Page 15
BLOWER DATA
BLOWER TABLE INCLUDES RESISTANCE FOR BASE UNIT ONLY WITH DRY INDOOR COIL & AIR FILTERS IN PLACE
FOR ALL UNITS ADD:
1 - Wet indoor coil air resistance of selected unit.
2 - Any factory installed options air resistance (electric heat, economizer, etc.)
3 - Any field installed accessories air resistance (electric heat, duct resistance, diffuser, etc.)
Then determine from blower table blower motor output and drive required.
See page 17 for wet coil and option/accessory air resistance data.
See page 17 for factory installed drive kit specifications.
MINIMUM AIR VOLUME REQUIRED FOR USE WITH OPTIONAL ELECTRIC HEAT
All units require 4955 L/s (10 500 cfm) minimum air with electric heat.
Air Volume
TOTAL STATIC PRESSURE - Pa (Inches Water Gauge)
100 (0.40)
150 (0.60)
kW BHP rev/
min
200 (0.80)
250 (1.00)
300 (1.20)
350 (1.40)
L/s
cfm
rev/
min
kW BHP
rev/
min
kW BHP
rev/
min
kW BHP
rev/
min
kW
BHP
rev/
min
kW
BHP
1890
4000
433 0.49 0.66 497 0.74 0.99
565
0.95 1.27
630
1.15 1.54
687
1.33
1.78
738
1.52
2.04
2125
4500
441 0.59 0.79 506 0.83 1.11
574
1.05 1.41
638
1.26 1.69
694
1.45
1.94
744
1.65
2.21
2360
5000
451
0.94 516 0.93 1.25
584
1.16 1.55
646
1.38 1.85
702
1.58
2.12
751
1.79
2.40
2595
5500
462 0.81 1.09 527 1.04 1.39
594
1.28 1.72
655
1.51 2.02
710
1.72
2.31
758
1.95
2.61
2830
6000
473 0.93 1.25 539 1.16 1.55
605
1.42 1.90
665
1.65 2.21
718
1.87
2.51
766
2.11
2.83
3070
6500
486 1.06 1.42 551
1.74
616
1.56 2.09
675
1.8
2.41
727
2.04
2.73
774
2.29
3.07
3300
7000
499 1.19 1.60 565 1.44 1.93
628
1.73 2.32
685
1.97 2.64
737
2.22
2.98
782
2.49
3.34
3540
7500
513 1.34 1.80 579
2.14
641
1.9
2.55
696
2.15 2.88
747
2.42
3.24
792
2.71
3.63
3775
8000
528 1.49 2.00 593 1.78 2.39
653
2.1
2.82
708
2.35 3.15
757
2.63
3.53
801
2.95
3.95
4010
8500
544 1.66 2.23 608 1.98 2.65
667
2.31 3.10
720
2.57 3.45
768
2.87
3.85
812
3.21
4.30
4245
9000
561 1.85 2.48 624
2.95
681
2.54 3.40
733
2.8
3.75
780
3.13
4.20
823
3.5
4.69
4480
9500
578 2.05 2.75 640 2.44 3.27
696
2.78 3.73
746
3.06 4.10
792
3.42
4.58
834
3.81
5.11
4720 10 000
596 2.28 3.06 657 2.69 3.61
711
3.04 4.08
760
3.34 4.48
805
3.73
5.00
845
4.15
5.56
4955 10 500
615 2.53 3.39 674 2.95 3.95
727
3.31 4.44
775
3.65 4.89
817
4.07
5.46
857
4.52
6.06
5190
11 000
634 2.79 3.74 692 3.22 4.32
744
3.61 4.84
789
3.99 5.35
830
4.44
5.95
869
4.91
6.58
5425
11 500
653 3.07 4.12 711 3.51 4.71
760
3.93 5.27
803
4.36 5.84
843
4.84
6.49
881
5.32
7.13
5660 12 000
674 3.38 4.53 729 3.83 5.13
776
4.29 5.75
818
4.77 6.39
857
5.27
7.06
894
5.75
7.71
5900 12 500
695 3.72 4.99 748
5.63
792
4.69 6.29
832
5.21 6.98
870
5.72
7.67
906
6.21
8.32
6130 13 000
715
5.50 766 4.61 6.18
808
5.14 6.89
847
5.68 7.61
883
6.21
8.32
918
6.7
8.98
6370 13 500
736 4.52 6.06 784 5.06 6.78
824
5.62 7.53
861
6.18 8.28
896
6.72
9.01
930
7.21
9.66
6605 14 000
757 4.98 6.68 801 5.55 7.44
839
6.14 8.23
875
6.71 8.99
909
7.25
9.72
943
7.74 10.38
6840 14 500
777 5.48 7.35 818 6.08 8.15
854
6.69 8.97
889
7.27 9.75
922
7.81 10.47
955
8.3
11.13
7075 15 000
797 6.02 8.07 834 6.66 8.93
868
7.28 9.76
902
7.86 10.54 935
8.4
---
---
---
0.7
4.1
1.3
1.6
2.2
4.2
11.26
CONTINUED ON NEXT PAGE
Energence® Packaged Electric / Electric 88 to 105 kW - 50 hz / Page 16
BLOWER DATA
BLOWER TABLE INCLUDES RESISTANCE FOR BASE UNIT ONLY WITH DRY INDOOR COIL & AIR FILTERS IN PLACE
FOR ALL UNITS ADD:
1 - Wet indoor coil air resistance of selected unit.
2 - Any factory installed options air resistance (electric heat, economizer, etc.)
3 - Any field installed accessories air resistance (electric heat, duct resistance, diffuser, etc.)
Then determine from blower table blower motor output and drive required.
See page 17 for wet coil and option/accessory air resistance data.
See page 17 for factory installed drive kit specifications.
MINIMUM AIR VOLUME REQUIRED FOR USE WITH OPTIONAL ELECTRIC HEAT
All units require 4955 L/s (10 500 cfm) minimum air with electric heat.
Air Volume
TOTAL STATIC PRESSURE - Pa (Inches Water Gauge)
400 (1.60)
450 (1.80)
kW BHP rev/
min
500 (2.00)
550 (2.20)
600 (2.40)
650 (2.60)
L/s
cfm
rev/
min
kW BHP
rev/
min
kW BHP
rev/
min
kW BHP
rev/
min
kW
BHP
rev/
min
kW
BHP
1890
4000
784 1.72 2.31 824 1.91 2.56
861
2.1
2.82
897
2.31 3.10
932
2.54
3.40
---
---
---
2125
4500
790 1.86 2.49 831 2.07 2.77
868
2.28 3.06
903
2.5
3.35
938
2.73
3.66
974
2.99
4.01
2360
5000
796 2.01 2.69 837 2.24 3.00
874
2.46 3.30
909
2.69 3.61
944
2.94
3.94
980
3.21
4.30
2595
5500
802 2.18 2.92 843 2.42 3.24
880
2.66 3.57
916
2.9
3.89
951
3.15
4.22
987
3.43
4.60
2830
6000
809 2.36 3.16 850 2.62 3.51
887
2.87 3.85
922
3.12 4.18
957
3.38
4.53
994
3.66
4.91
3070
6500
817 2.56 3.43 857 2.83 3.79
894
3.1
4.16
929
3.35 4.49
964
3.62
4.85
1001 3.91
5.24
3300
7000
825 2.78 3.73 864 3.07 4.12
901
3.34 4.48
937
3.6
4.83
971
3.87
5.19
1008 4.17
5.59
3540
7500
833 3.02 4.05 872 3.32 4.45
909
3.61 4.84
945
3.88 5.20
979
4.15
5.56
1016 4.45
5.97
3775
8000
843 3.28 4.40 881
4.83
918
3.89 5.21
953
4.17 5.59
988
4.45
5.97
1025 4.75
6.37
4010
8500
852 3.56 4.77 890 3.89 5.21
927
4.2
5.63
962
4.49 6.02
997
4.77
6.39
1034 5.08
6.81
4245
9000
862 3.87 5.19 900 4.22 5.66
936
4.53 6.07
972
4.82 6.46 1007 5.11
6.85
1044 5.43
7.28
4480
9500
873 4.21 5.64 910 4.56 6.11
946
4.88 6.54
982
5.17 6.93 1018 5.47
7.33
1055
5.8
7.77
4720 10 000
884 4.57 6.13 921 4.93 6.61
957
5.24 7.02
992
5.54 7.43 1028 5.86
7.86
1066
6.2
8.31
4955 10 500
895 4.94 6.62 932 5.31 7.12
967
5.63 7.55 1003 5.93 7.95 1039 6.27
8.40
1077 6.63
8.89
5190
11 000
907 5.34 7.16 943 5.71 7.65
978
6.03 8.08 1013 6.35 8.51 1050
6.7
8.98
1089 7.08
9.49
5425
11 500
918 5.75 7.71 954 6.13 8.22
989
6.46 8.66 1025 6.78 9.09 1062 7.15
9.58
1101 7.55 10.12
3.6
5660 12 000
930 6.19 8.30 965 6.57 8.81 1000
5900 12 500
941 6.65 8.91 976 7.03 9.42 1011 7.37 9.88 1048 7.72 10.35 1085
8.1
6130 13 000
953 7.13 9.56 988 7.51 10.07 1023 7.85 10.52 1059 8.21 11.01
---
---
---
---
---
---
6370 13 500
965 7.64 10.24 1000 8.01 10.74 1035 8.35 11.19
---
---
---
---
---
---
---
---
---
6605 14 000
977 8.16 10.94 1012 8.53 11.43
---
---
---
---
---
---
---
---
---
---
6.9
---
9.25 1036 7.24 9.71 1073 7.62 10.21 1112 8.03 10.76
---
10.86 1124 8.52 11.42
Energence® Packaged Electric / Electric 88 to 105 kW - 50 hz / Page 17
BLOWER DATA
FACTORY INSTALLED BELT DRIVE KIT SPECIFICATIONS
Nominal
kW
Nominal
hp
Maximum
kW
Maximum
hp
Drive Kit
Number
Rev/min
Range
3.7
5
4.3
5.75
5
550 - 675
3.7
5
4.3
5.75
6
640 - 805
3.7
5
4.3
5.75
7
475 - 600
3.7
5
4.3
5.75
8
400 - 525
3.7
5
4.3
5.75
9
340 - 445
5.6
7.5
6.4
8.63
3
595 - 730
5.6
7.5
6.4
8.63
4
640 - 805
7.5
10
8.6
11.50
1
615 - 745
7.5
10
8.6
11.50
2
725 - 870
NOTE - Using total air volume and system static pressure requirements determine from blower performance tables rev/min and motor output required. Maximum
usable output of motors furnished as shown. If motors of comparable output are used, be sure to keep within the service factor limitations outlined on the motor
nameplate.
FACTORY INSTALLED OPTIONS/FIELD INSTALLED ACCESSORY AIR RESISTANCE
Air
Volume
Electric
Heat
Wet Indoor Coil
Economizer
Filters
MERV 8
MERV 13
Horizontal
Roof Curb
L/s
cfm
Pa
in. w.g.
Pa
in. w.g.
Pa
in. w.g.
Pa
in. w.g.
Pa
in. w.g.
Pa
in. w.g.
1890
4000
10
0.04
2
0.01
0
0.00
0
0.00
0
0.00
10
0.04
2125
4500
10
0.04
2
0.01
0
0.00
0
0.00
0
0.00
12
0.05
2360
5000
12
0.05
2
0.01
0
0.00
0
0.00
0
0.00
15
0.06
2595
5500
15
0.06
5
0.02
2
0.01
0
0.00
2
0.01
17
0.07
2830
6000
17
0.07
5
0.02
2
0.01
0
0.00
5
0.02
20
0.08
3070
6500
20
0.08
5
0.02
2
0.01
2
0.01
5
0.02
22
0.09
3300
7000
22
0.09
7
0.03
5
0.02
2
0.01
7
0.03
25
0.10
3540
7500
25
0.10
7
0.03
5
0.02
2
0.01
10
0.04
27
0.11
3775
8000
27
0.11
7
0.03
5
0.02
2
0.01
10
0.04
32
0.13
4010
8500
30
0.12
10
0.04
7
0.03
2
0.01
10
0.04
37
0.15
4245
9000
32
0.13
10
0.04
10
0.04
2
0.01
10
0.04
42
0.17
4480
9500
35
0.14
12
0.05
10
0.04
5
0.02
15
0.06
47
0.19
4720
10 000
37
0.15
12
0.05
12
0.05
5
0.02
15
0.06
52
0.21
4955
10 500
40
0.16
15
0.06
15
0.06
5
0.02
15
0.06
60
0.24
5190
11 000
45
0.18
15
0.06
17
0.07
5
0.02
17
0.07
67
0.27
5425
11 500
47
0.19
17
0.07
20
0.08
5
0.02
20
0.08
75
0.30
5660
12 000
50
0.20
17
0.07
25
0.10
5
0.02
20
0.08
82
0.33
5900
12 500
52
0.21
20
0.08
27
0.11
7
0.03
25
0.10
92
0.37
6130
13 000
57
0.23
20
0.08
32
0.13
7
0.03
25
0.10
100
0.40
6370
13 500
60
0.24
22
0.09
35
0.14
7
0.03
27
0.11
110
0.44
6605
14 000
65
0.26
25
0.10
40
0.16
7
0.03
30
0.12
122
0.49
6840
14 500
67
0.27
25
0.10
45
0.18
10
0.04
32
0.13
132
0.53
7075
15 000
72
0.29
27
0.11
52
0.21
10
0.04
32
0.13
144
0.58
Energence® Packaged Electric / Electric 88 to 105 kW - 50 hz / Page 18
BLOWER DATA
CEILING DIFFUSER AIR RESISTANCE
Step-Down Diffuser - LARTD30/36
Air Volume
2 Ends Open
1 Side/2 Ends Open
All Ends & Sides Open
Flush Diffuser LAFD30/36
L/s
cfm
Pa
in. w.g.
Pa
in. w.g.
Pa
in. w.g.
Pa
in. w.g.
3540
7500
92
0.37
77
0.31
62
0.25
72
0.29
3775
8000
104
0.42
90
0.36
72
0.29
85
0.34
4010
8500
119
0.48
102
0.41
85
0.34
97
0.39
4245
9000
137
0.55
117
0.47
97
0.39
109
0.44
4485
9500
154
0.62
132
0.53
112
0.45
127
0.51
4720
10000
174
0.70
149
0.60
127
0.51
142
0.57
4955
10 500
194
0.78
169
0.68
144
0.58
162
0.65
5190
11 000
216
0.87
190
0.76
162
0.65
179
0.72
5425
11 500
241
0.97
211
0.85
182
0.73
201
0.81
5665
12 000
269
1.08
234
0.94
204
0.82
223
0.90
5900
12 500
296
1.19
259
1.04
226
0.91
246
0.99
6135
13 000
323
1.30
286
1.15
249
1.00
274
1.10
6370
13 500
356
1.43
313
1.26
374
1.10
298
1.20
6605
14 000
388
1.56
343
1.38
298
1.20
326
1.31
6845
14 500
420
1.69
373
1.50
326
1.31
356
1.43
7080
15 000
457
1.84
405
1.63
356
1.43
388
1.56
CEILING DIFFUSER AIR THROW DATA
1
Air Volume
1
Effective Throw Range
Step-Down
Flush
L/s
cfm
m
ft.
m
ft.
4245
4485
4720
4955
4190
5425
5665
5900
6135
6370
9000
9500
10 000
10 500
11 000
11 500
12 000
12 500
13 000
13 500
12 - 14
13 - 15
14 - 16
15 - 18
16 - 19
17 - 20
18 - 20
19 - 22
20 - 23
20 - 23
40 - 47
43 - 50
46 - 54
50 - 58
53 - 61
55 - 64
58 - 67
61 - 71
64 - 74
67 - 77
8 - 11
10 - 12
11 - 14
13 - 15
14 - 17
15 - 19
16 - 20
18 - 22
19 - 23
20 - 24
29 - 35
33 - 41
37 - 46
42 - 51
46 - 56
50 - 61
54 - 66
58 - 71
62 - 75
66 - 79
Throw is the horizontal or vertical distance an airstream travels on leaving the outlet or diffuser before the maximum velocity is
reduced to 15 m (50 ft.) per minute. Four sides open.
POWER EXHAUST FAN PERFORMANCE - STANDARD STATIC
Return Duct Negative Static Pressure
Air Volume Exhausted
Pa
in. w.g.
L/s
cfm
0
0
6040
12 800
12
0.05
5760
12 200
25
0.10
5430
11 500
37
0.15
5100
10 800
50
0.20
4670
9900
62
0.25
4250
9000
75
0.30
3730
7900
87
0.35
3190
6750
100
0.40
2570
5450
112
0.45
1960
4150
125
0.50
1370
2900
Energence® Packaged Electric / Electric 88 to 105 kW - 50 hz / Page 19
ELECTRICAL/ELECTRIC HEAT DATA
LCH300H4B
LCH360H4B
380/420V
380/420V
Rated Load Amps
Locked Rotor Amps
Rated Load Amps
Locked Rotor Amps
Rated Load Amps
Locked Rotor Amps
Rated Load Amps
Locked Rotor Amps
Full Load Amps
10.6
74
10.6
74
10.6
74
10.6
74
1.3
12.2
101
12.2
101
12.2
101
12.2
101
1.3
(total)
Full Load Amps
(7.8)
1.3
(7.8)
1.3
Voltage - 50hz 3 Phase with neutral
1
Compressor 1
Compressor 2
Compressor 3
Compressor 4
Outdoor Fan
Motors (6)
Standard Power
Exhaust (3) 0.25 kW
(total)
kW
Full Load Amps
Unit Only
Indoor Blower
Motor
Maximum
Overcurrent
Protection
2
(3.9)
5.6
11.7
70
7.5
16.3
80
3.7
8.2
80
(3.9)
5.6
11.7
80
7.5
16.3
90
70
80
90
80
80
90
62
65
65
69
71
75
68
72
72
76
77
81
420V
70
70
80
110
150
62
70
74
105
137
70
80
80
110
150
65
75
79
110
142
420V
70
80
80
110
150
65
74
78
110
141
80
80
90
125
150
69
79
83
115
146
420V
80
80
90
125
150
71
80
84
116
147
90
90
90
125
175
75
85
89
120
152
420V
80
80
80
110
150
68
70
74
105
137
80
80
80
110
150
72
75
79
110
142
420V
80
80
80
110
150
72
74
78
110
141
80
80
90
125
150
76
79
83
115
146
420V
90
90
90
125
150
77
80
84
116
147
90
90
90
125
175
81
85
89
120
152
With (3) 0.25 kW
Standard Power Exhaust
Unit Only
With (3) 0.25 kW
Standard Power Exhaust
Minimum
Circuit
Ampacity
3
3.7
8.2
70
ELECTRIC heat data
2
Electric Heat Voltage
Unit+
23 kW
4
Electric Heat
34.5 kW
Maximum
Overcurrent
Protection
Minimum Circuit
Ampacity
3
2
4
45.9 kW
68.9 kW
91.9 kW
23 kW
34.5 kW
45.9 kW
68.9 kW
91.9 kW
23 kW
34.5 kW
45.9 kW
68.9 kW
91.9 kW
23 kW
34.5 kW
45.9 kW
68.9 kW
91.9 kW
Unit+
Electric Heat
Maximum
Overcurrent
Protection
Unit+
Electric Heat
and Standard
Power Exhaust
(3) 0.25 kW
Minimum
Circuit
Ampacity
Unit+
Electric Heat
and Standard
Power Exhaust
(3) 0.25 kW
4
3
4
Extremes of operating range are plus and minus 10% of line voltage.
Heating, Air Conditioning, Refrigeration (HACR) type breaker or fuse.
3
Refer to local electrical code to determine wire, fuse and disconnect size requirements.
4
Nominal kW based on 420V-3ph-50hz.
1
2
ELECTRIC HEAT CAPACITIES
Volts
Input
23 kW
34.5 kW
45.9 kW
68.9 kW
91.9 kW
kW
Btuh No. of kW
Btuh No. of kW
Btuh No. of
kW
Btuh No. of
kW
Input Output Stages Input Output Stages Input Output Stages Input Output Stages Input
Btuh No. of
Output Stages
380
18.8
64 200
1
28.2
93 600
2
37.6 128 400
2
56.4
192 500
2
75.2
236 700
2
400
20.8
71 100
1
31.2 106 700
2
41.6 142 200
2
62.5
213 200
2
83.4
261 000
2
420
23.0
78 400
1
34.4 117 600
2
45.9 156 800
2
68.9
235 100
2
91.9
313 700
2
Energence® Packaged Electric / Electric 88 to 105 kW - 50 hz / Page 20
UNIT CLEARANCES - MM (INCHES)
Unit With Economizer
C
OUTDOOR
AIR HOOD
D
B
A
1
Unit Clearance
A
B
C
D
mm
in.
mm
in.
mm
in
mm
in.
Service Clearance
1524
60
914
36
914
36
1676
66
Minimum Operation Clearance
1143
45
914
36
914
36
1041
41
Top
Clearance
Unobstructed
NOTE - Entire perimeter of unit base requires support when elevated above the mounting surface.
1
S
ervice Clearance - Required for removal of serviceable parts.
Minimum Operation Clearance - Required clearance for proper unit operation.
Unit With Horizontal Barometric Relief Dampers
OPTIONAL BAROMETRIC
RELIEF EXHAUST
DAMPERS
(Field Installed
on Return Air Duct)
NOTE Allow adequate clearance for duct and
barometric relief damper installation.
NOTE Dampers may be installed on each side
of return air duct or end to end on one side of
return air duct.
OUTDOOR
AIR HOOD
C
B
A
1
Unit Clearance
A
B
C
mm
in.
mm
in.
mm
in.
Service Clearance
1524
60
914
36
1676
66
Minimum Operation Clearance
1143
45
914
36
1041
41
Top
Clearance
Unobstructed
NOTE - Entire perimeter of unit base requires support when elevated above the mounting surface.
1
Service Clearance - Required for removal of serviceable parts.
Minimum Operation Clearance - Required clearance for proper unit operation.
Energence® Packaged Electric / Electric 88 to 105 kW - 50 hz / Page 21
OPTIONAL CONVENTIONAL TEMPERATURE CONTROL SYSTEMS - FIELD INSTALLED
COMMERCIAL TOUCHSCREEN THERMOSTAT
Intuitive Touchscreen Interface - Two Stage Heating / Two Stage Cooling
Conventional or Heat Pump - Seven Day Programmable - Four Time Periods/
Day - Economizer Output - Title 24 Compliant - ENERGY STAR® Qualified Backlit Display - Automatic Changeover
C0STAT02AE1L
(14W81)
Sensors For Touchscreen Thermostat
1
Remote non-adjustable wall mount 20k temperature sensor..........................
C0SNZN01AE2-
1
Remote non-adjustable wall mount 10k averaging temperature sensor.........
C0SNZN73AE1-
1
Remote non-adjustable duct mount temperature sensor................................
C0SNDC00AE1-
Outdoor temperature sensor.............................................................................
C0SNSR03AE1-
(47W36)
(47W37)
(19L22)
(X4148)
Accessories For Touchscreen Thermostat
Locking cover (clear).........................................................................................
C0MISC15AE1(39P21)
1
Remote sensors for C0STAT02AE1L can be applied in the following combinations: (1)
C0SNZN01AE1-, (2) C0SNZN73AE1-, (2) C0SNZN01AE1- and (1) C0SNZN73AE1-, (4)
C0SNZN01AE1-, (3) C0SNZN01AE1- and (2) C0SNZN73AE1.
DIGITAL NON-PROGRAMMABLE THERMOSTATS
Intuitive Interface - Automatic Changeover - Backlit Display - Simple Up and Down Temperature Control
One-stage heating / cooling conventional systems...........................................
C0STAT12AE1L
(51M32)
Sensor For Digital Non-Programmable Thermostats Above
Outdoor temperature sensor.............................................................................
C0SNSR04AE1(X2658)
Accessories For Digital Non-Programmable Thermostats Above
Optional wall mounting plate.............................................................................
C0MISC17AE1(X2659)
OUTDOOR SOUND DATA
Unit
Model Number
300/360
Octave Band Sound Power Levels dBA, re 10-12 Watts Center Frequency - HZ
125
250
500
1000
2000
4000
8000
Sound Rating
Number (dB)
84
85
90
90
85
80
72
95
Note - The octave sound power data does not include tonal corrections.
1
Sound Rating Number according to AHRI Standard 370-2001.
Energence® Packaged Electric / Electric 88 to 105 kW - 50 hz / Page 22
1
WEIGHT DATA
Net
Model Number
Shipping
kg
lbs.
kg
lbs.
300 Base Unit
1359
2997
1455
3207
300 Max. Unit
1546
3409
1642
3619
360 Base Unit
1359
2997
1455
3207
360 Max. Unit
1546
3409
1642
3619
OPTIONS / ACCESSORIES
Shipping Weight
Description
kg
lbs.
LARTD30/36
198
437
CEILING DIFFUSERS
Step-Down
Flush
LAFD30/36
188
414
LASRT30/36
39
85
E1ECON15D-1
54
119
Downflow Barometric Relief Dampers
E1DAMP60D-1
20
45
Horizontal Barometric Relief Dampers
LAGEDH30/36
9
20
Damper Section (downflow)
Motorized - E1DAMP25D-1-
33
72
Damper Section (downflow)
Manual - E1DAMO15D-1-
31
68
LAOAH30/36
34
76
Standard Static - E1PWRE40D
45
99
23 kW
C1EH0300C
27
59
34.5 kW
C1EH0450C
34
76
45.9 kW
C1EH0600C
34
76
68.9 kW
C1EH0900C
38
84
91.9 kW
C1EH1200D
44
98
136
300
Transitions
ECONOMIZER / OUTDOOR AIR / EXHAUST
Economizer
Barometric Relief
Outdoor Air Dampers
Outdoor Air Hood (downflow)
Power Exhaust
ELECTRIC HEAT
PACKAGING
LTL Packaging (less than truck load)
ROOF CURBS - STANDARD
Downflow
356 mm height
LARMF18/36-14
73
160
610 mm height
LARMF18/36-24
100
220
762 mm height
LARMFH30/36-30
202
445
1041 mm height
LARMFH30/36-41
329
725
Horizontal
Energence® Packaged Electric / Electric 88 to 105 kW - 50 hz / Page 23
DIMENSIONS - MM (INCHES)
Model No.
AA
LCH300 Base Unit
LCH300 Max. Unit
LCH360 Base Unit
LCH360 Max. Unit
kg
277
315
277
315
lbs.
610
693
610
693
kg
278
316
278
316
CORNER WEIGHTS
BB
CC
lbs.
kg
lbs.
612
399
880
696
454
1001
612
399
880
696
454
1001
CENTER OF GRAVITY
EE
FF
mm
in.
mm
1524
60
940
1524
60
940
1524
60
940
1524
60
940
DD
kg
406
462
406
462
lbs.
895
1018
895
1018
in.
37
37
37
37
Base Unit - The unit with NO INTERNAL OPTIONS.
Max. Unit - The unit with ALL INTERNAL OPTIONS Installed. (Economizer, Standard Static Power Exhaust Fans, Controls, etc.). Does not include accessories external
to unit or high static power exhaust.
EE
108
(4-1/4)
AA
146
(5-3/4)
BB
381 (15)
1994 (78-1/2)
BOTTOM RETURN
AIR OPENING
457 (18)
445
(17-1/2)
711
(28)
508 (20)
CENTER OF
GRAVITY
711
(28)
114 508 (20)
(4-1/2)
FF
BOTTOM SUPPLY
AIR OPENINGS
DD
229 (9)
102 (4)
CC
BOTTOM POWER ENTRY
127 X 203 mm (5 X 8 inches)
TOP VIEW
2289 (90-1/8)
3683 (145)
137
(5-3/8)
SIDE
ELECTRICAL
INLETS
1568
(61-3/4)
83
(3-1/4)
800
(31-1/2)
OPTIONAL
OUTDOOR
GRILLE KIT
(Field Installed)
(Both Sides)
1651
(65)
CONDENSATE
DRAIN
2305 (90−3/4)
END VIEW
Energence® Packaged Electric / Electric 88 to 105 kW - 50 hz / Page 24
FORKLIFT SLOTS
(Front and Left Side Only)
3042 (119−3/4)
SIDE VIEW
LIFTING HOLES
(For Rigging
Front and Back)
654
(25-3/4)
ACCESSORY DIMENSIONS - MM (INCHES)
OPTIONAL OUTDOOR AIR HOOD DETAIL
WITH STANDARD STATIC POWER EXHAUST FANS
648
(25−1/2)
OPTIONAL
OUTDOOR AIR HOOD
(Factory or Field Installed)
Required with Economizer or
Outdoor Air Damper
1 OPTIONAL
STANDARD STATIC
POWER EXHAUST
FANS HOOD
(Field Installed)
1
Field Installed in Return Air Duct for Horizontal Applications.
HORIZONTAL BAROMETRIC RELIEF DAMPERS
(Field installed in horizontal return air duct adjacent to unit)
1384 (54−1/2)
1334 (1 52−1/2)
165
(6-1/2)
FRONT VIEW
SIDE VIEW
368
(14-1/2)
330
(1 13)
NOTE − Two furnished per order no.
1 NOTE − Opening size required in return air duct.
Energence® Packaged Electric / Electric 88 to 105 kW - 50 hz / Page 25
ACCESSORY DIMENSIONS - MM (INCHES)
STANDARD ROOF CURBS - DOUBLE DUCT OPENING
46 (1-13/16)
44 (1-3/4)
406 (16)
2191
(86-1/4)
2099
(82-5/8)
432 (17)
2019
(79-1/2)
533 (21)
2502
(98-1/2)
CURB
RETURN AIR
OPENING
46
(1-13/16)
337
(13-1/4)
2594
(102-1/8)
CURB
SUPPLY AIR
OPENING
356 (14)
or
610 (24)
1562
(61-1/2)
19 (3/4) Typ.
TYPICAL FLASHING DETAIL FOR ROOF CURB
BASE BOTTOM
DETAIL ROOF CURB
46
(1-13/16)
PACKAGED
UNIT
25 (1)
FIBERGLASS
INSULATION
(Furnished)
COUNTER FLASHING
(Field Supplied)
FACTORY INSTALLED
PERIMETER WOOD
NAILER STRIP
NAILER STRIP
(Furnished)
ROOF CURB
(Extends around entire
perimeter of unit)
CANT STRIP
(Field Supplied)
ROOFING
MATERIAL
356 (14)
610 (24)
RIGID INSULATION
(Field Supplied)
51 (2)
Energence® Packaged Electric / Electric 88 to 105 kW - 50 hz / Page 26
ACCESSORY DIMENSIONS - mm (inches)
ROOF CURBS WITH SUPPLY & RETURN AIR TRANSITIONS FOR CEILING DIFFUSERS
2051 (80-3/4)
1524 (60)
114 (4-1/2)
1524 (60)
SUPPLY AIR
OPENINGS
711
(28)
LASRT RETURN
TRANSITION
711
(28)
SUPPORT
ANGLE
(Furnished with
Transitions)
TRANSITION DETAIL
38
(1-1/2) Typ.
1372
(54)
356 305
(12)
(14)
LASRT SUPPLY
TRANSITION
RETURN
AIR OPENING
A
A
51
(2)
19
(3/4)Typ.
673
(26-1/2)
673
(26-1/2)
LASRT SUPPLY
TRANSITION
LASRT RETURN
TRANSITION
711
(28)
114
(4-1/2)
711
(28)
SECTION B-B
TOP VIEW
Energence® Packaged Electric / Electric 88 to 105 kW - 50 hz / Page 27
ACCESSORY DIMENSIONS - MM (INCHES)
HORIZONTAL ROOF CURBS − Requires Optional Horizontal Return Air Panel Kit
46 (1-13/16)
46
(1-13/16)
2594 (102-1/8)
2502 (98-1/2)
Frame
Opening
NOTE LARMFH30/36-30 is designed for horizontal discharge
when unit is mounted on a slab.
LARMFH30/36-41 is designed for horizontal
discharge when unit is mounted on a rooftop.
46 (1-13/16)
Frame
762 (30)
1041 (41)
Opening
1
2
25 (1)
NAILER STRIP
(Furnished)
51 (1)
A
A
SECTION A-A
2099
(82-5/8)
PANEL TO COVER RETURN AIR OPENING IN BOTTOM OF UNIT
(Furnished With Optional Horizontal Return Air Panel Kit)
2502 (98-1/2)
2191
(86-1/4)
SUPPLY AIR
TURNING VANE
(Furnished)
1372
(54)
SIDE VIEW
NOTE − Roof deck may be omitted within confines of curb.
(PACKAGED UNIT)
46 (1-13/16)
TOP VIEW
1, 2
NAILER STRIP
(Furnished)
337 (13-1/4)
2594 (102-1/8)
2191 (86-1/4)
140 (5-1/2)
1
2
762 (30)
1041 (41)
75 (1905)
CURB SUPPLY AIR OPENING
With 38 mm (1-1/2 in.) FLANGE
1, 2
SUPPLY AIR
TURNING VANE
(Furnished)
457 (18)
1165
2 445
(6-1/2)
(17-1/2)
2604 (102-1/2)
2200 (86-5/8)
FRONT VIEW
1
SUPPLY
DUCT
PANELS
(Furnished)
SIDE VIEW
LARMFH30/36-30 2 LARMFH30/36-41
HORIZONTAL SUPPLY AND RETURN AIR OPENINGS
ROOFTOP UNIT WITH HORIZONTAL ROOF CURB
OPTIONAL RETURN AIR PANEL KIT
(Required For Horizontal Applications)
1651
(65)
2311 (91)
LARMFH30/36-30
2591 (102)
LARMFH30/36-41
1994 (78-1/2)
381 (15)
HORIZONTAL RETURN
AIR OPENING
51 (2)
1
660 (26)
LARMFH30/36-30
940 (37)
LARMFH30/36-41
1905 (75)
HORIZONTAL
SUPPLY AIR OPENING
1
1 NOTE − Top of Curb extends 102 mm (4 inch) inside
bottom of unit base. See Typical Flashing Detail.
1089
(42-7/8)
HORIZONTAL ROOF CURB
(Required For Horizontal Applications)
SIDE VIEW
(Horizontal Openings)
Energence® Packaged Electric / Electric 88 to 105 kW - 50 hz / Page 28
457 (18)
133
(5-1/4)
337
(13-1/4)
165 (6-1/2)
LARMFH30/36-30
445 (17-1/2)
LARMFH30/36-41
ACCESSORY DIMENSIONS - MM (INCHES)
COMBINATION CEILING SUPPLY AND RETURN DIFFUSERS
STEP-DOWN CEILING DIFFUSER
F
E
G
G
H
FLUSH CEILING DIFFUSER
F
E
D
J
K
G
G
H
D
J
K
C
C
51 (2)
51 (2)
N
B
B
M
L
Model Number
A
LARTD30/36
mm
in.
B
mm
in.
C
mm
in.
D
mm
in.
E
mm
in
F
mm
in
G
H
J
K
L
1029
1613
114
38
mm
1524
in.
60
mm
44
in.
1-3/4
mm
1613
mm
mm
in.
63-1/2
mm
mm
in.
D
mm
in.
E
mm
in.
F
4-1/2
1-1/2
mm
in.
C
63-1/2
in.
mm
B
63-1/2
1613
LAFD30/36
in.
40-1/2
28
mm
A
65-5/8
in.
in.
Duct Size
1667
711
in.
N
1667
Model Number
65-5/8
mm
in.
M
A
A
mm
in.
G
H
J
K
1667
65-5/8
1016
40
1613
63-1/2
1613
63-1/2
108
4-1/4
mm
711
in
28
mm
32
in.
1-5/8
mm
1524
in.
60
mm
44
in.
Duct Size
1667
65-5/8
mm
in.
1-3/4
711 x 1524
28 x 60
1613
63-1/2
308
12-1/8
711 x 1524
28 x 60
Energence® Packaged Electric / Electric 88 to 105 kW - 50 hz / Page 29
REVISIONS
Section
Description
Blower Data
Air resistance data for wet indoor coil updated.
Options/Accessories
Updated catalog number for Stainless Steel Condensate Drain Pan.
Visit us at www.lennox.com
For the latest technical information, www.lennoxcommercial.com
Contact us at 1-800-4-LENNOX
NOTE - Due to Lennox’ ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability.
Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury.
Installation and service must be performed by a qualified installer and servicing agency.
©2013 Lennox Industries, Inc.
Download PDF
Similar pages