IPX Series
MU LTI-CHANNEL POWER AMPLIFIERS
F I X E D I N S TA L L A P P L I C AT I O N S
IPX SERIES
STANDS OUT FROM
THE CROWD.
WITH BRAINS,
POWER AND
EFFICIENCY.
IPX Series
THE PINNACLE OF AMPLIFIER ENGINEERING
IPX series multi-channel power amplifiers mark the
new, unprecedented standard for sound system
amplification in mid to large-sized permanent installations. Our new high-performance amplifiers
offer seemingly unlimited power and pristine
audio quality. IPX series multi-channel power
amplifiers are featuring OMNEO IP networking architecture and groundbreaking audio performance. They embody
several proprietary amplifier technologies developed by Dynacord
engineering, one of the most
experienced R&D teams in
the audio industry.
IPX series can cover a wide range of demanding fixed
installation venues, from concert halls, art centres,
theatres, and houses of worship to distributed sound
systems in stadiums and entertainment centres. The new
Eco Rail technology developed by Dynacord helps to
reduce overall power consumption up to 50%, both
protecting the environment and significantly lowering
the total cost of ownership, while maintaining highquality audio and operational safety at all times. As
installers increasingly utilize existing networks in building
infrastructure, relying on IP technology often results in
faster system integrations and lower implementation
costs – including reduced cabling – for substantial cost
savings. The integrated OMNEO interface with a primary
and secondary port allows the flawless use of 8 channels
from a Dante audio network, while remote and supervision
parameters run on OCA protocol (AES70), open for thirdparty integration. Redundancy options include glitch-free
and RSTP to suit individual requirements and existing
infrastructure.
models
HIGH POWER DENSITY
IPX series amplifiers represent the perfect mix of seemingly
unlimited power with cutting edge intelligent FIR-drive DSP to give
you the power and the ultimate performance for any demanding
sound system requirements in permanent installations. Engineered
and made in Germany, the IPX series power amplifiers comprise
three 4-channel models and one 8-channel model, offering a power
density of 5 kW, 10 kW and even 20 kW from a single amplifier
with all channels driven.
IPX5:4
4 x 1,250 W @ 4 Ω
(maximum output power per channel*)
MOST SOPHISTICATED DIGITAL SIGNAL
PROCESSING AVAILABLE
The IPX series offers advanced 96 kHz high-resolution digital signal
processing for the highest performance, internal analog-to-digital
conversion with ultra-low latency, and a superior signal-to-noise
ratio. The three DSP blocks are split into user-, array- and speaker
processing controls, each featuring a wide range of EQ-, delay
and level options to match a wide range of applications. Complete
remote control and supervision is available via the powerful IRISNet software and allows the IPX series to be seamlessly integrated
into both existing and new installations
4 x 2,500 W @ 4 Ω
(maximum output power per channel*)
ADVANCED POWER MANAGEMENT
FOR REDUCED COSTS AND FLAWLESS
PERFORMANCE – EVEN UNDER
CHALLENGING CONDITIONS
IPX10:8
The new Eco Rail technology developed by Dynacord helps to
reduce overall power consumption up to 50%, both protecting
the environment and significantly lowering the total cost of
ownership, while maintaining high-quality audio and operational
safety at all times. The fully DSP-controlled amplifier and power
supply constantly monitors up to 280 parameters simultaneously
to assure that even under challenging operating conditions such
as mains power fluctuations, the IPX series continues to perform
at highest possible level, rather than switching into a protect mode
and stop operation.
IPX10:4
8 x 1,250 W @ 4 Ω
(maximum output power per channel*)
IPX20:4
4 x 5,000 W @ 4 Ω
(maximum output power per channel*)
HIGH INSTALLATION FLEXIBILITY
IPX series offers high flexibility for a variety of installation scenarios.
This is ensured by several power drive options utilizing Dynacord’s
patented VLD technology as well as the newly developed parallel
and parallel-bridged operation modes. VLD technology allows the
available output power of e.g. 1,250 watts per channel to be used
at either 4 or 8 Ohms, or via 70 V or 100 V lines in direct drive
mode.
* Measured with all channels driven
technology
For over 70 years, Dynacord has designed and engineered professional audio systems – products
that offer unparalleled performance and premium quality, the perfect balance of power and precision.
Our industrial design combines finely tuned form with feature-rich functionality across every detail –
clean lines and clean sound – and our dedication to durability is demonstrated in the industry’s most
rigorous product testing programs.
Our amplifier expertise and applied technologies will give our IPX series amplifiers ultimate protection
from damage and ensure flawless operation - even under the most challenging conditions. In
addition, our engineering technology also contributes to significantly reduce operation costs while
maintaining the best audio quality. This is ensured and backed up by a series of new, sophisticated
Dynacord technologies.
technology
ABOUT OMNEO
OMNEO is an architectural approach to connecting devices that need to exchange information
such as audio content or device control. Built upon multiple technologies, including IP and open
public standards, OMNEO supports the technologies of today – such as Audinate’s Dante – while
adopting the standards of tomorrow. OMNEO offers a professional-grade media networking
solution that provides interoperability, unique features for easier installation, better performance,
and greater scalability than any other IP offering on the market.
output current over temperature
RAIL-voltage [V]
current
200
150
100
50
IPX SERIES
STANDS OUT FROM
THE CROWD.
0
-50
-100
-150
time
-200
audio output voltage
+ RAIL
- RAIL
ECO RAIL TECHNOLOGY
•
Reduces standby losses to a minimum
•
All monitoring functions are maintained
•
No transient currents or distortions during switching
•
Fully automatized - no user interaction needed
WITH BRAINS,
POWER AND
JTM - JUNCTION TEMPERATURE
EFFICIENCY.
MODELLING
temperature
border of SOA
conventional SOA protection
safety margin
JTM
•
Overheat component protection by constant
temperature modelling
•
Ensures maximum output power
•
Provides highest operational reliability
Output power
Output power over load impedance
mains voltage
audio output voltage
mains current (smart PFC)
SMART PFC - POWER FACTOR
CORRECTION
•
Maximizes output power and reduces idle power
•
Complete digital monitoring and control
•
Wide range input for maximum flexibility
•
Highest reliability thanks to Dynacord’s
Protection Package
Impedance
operating area with
overcurrent shutdown
extended operating area with
cycle by cycle current limiter
maximum output power
limited by output voltage
maximum output power
limited by output current
CYCLE BY CYCLE CURRENT
LIMITER
•
Continue to make sound
•
Maximizes reliability under all load conditions
•
Able to drive low impedance
LF
HF
LF
HF
IPX10:4
application
LF
F1
HF
F2
F3
S
F4
F5
S
F6
F7
IPX10:4
F8
D1 D2 D3 D4 D5 D6 D7 D8
IPX10:8
IPX10:8
CLUB
Club
City Hall
DJ Monitor
Fill
1250/8 1250/8 1250/8 1250/8
1250/4
1250/4
1250/4
1250/4
S
Subwoofer
Main
1
MainDelay
2
2500/4 2500/4
2500/4
Side 1&2Left
2500/4 2500/4
1250/4
Right
1250/8
1250/4
2500/4
Fill
100 V
2500/4
1 1
5000/4
5000/4
5000/4
STADIUM
Performing
5000/4
F1
F2
F3
F4
LF
HF
LF
HF
LF
HF
LF
HF
LF
HF
LF
HF
5000/4
3
4
5
6
7
S
S
S
S
S
S
S
S
S
S
S
S
LF
HF
LF
HF
IPX10:8
IPX10:4
5000/4
5000/4
IPX10:4
IPX10:4
8
5000/4
IPX10:8
5000/4
T
1300/2
Subwoofer
5000/4
S
1250/8
...
5000/4
T
IPX20:4
IPX20:4
5000/4
IPX20:4
Arts Center / Theater
IPX10:4
TRIBUNESLeft
Fill
Center
Cluster 3
Cluster 4
Right
Cluster 5
Cluster 6
Cluster 7
LF
HF
S
S
LF
HF
LF
HF
IPX10:4
Cluster 8
Upper
IPX10:4
Middle
Delay
Lower
UNDER BALCONY 70/100 V
B
A
A
LF
HF
S
S
LF
HF
LF
HF
IPX10:4
B
A
B
A
B
A
B
LF
Field 1
FIELD
Field 2
Field 3
IPX10:4
IPX10:4
City Hall
HF
S
S
IPX10:4
Field 4
F1
IPX10:4
IPX10:4
4U
4L
3M
UBA
3U
3L
4M
UBB
6U
6L
5M
F1
5U
5L
6M
F2
8U
8L
7M
F3
7U
7L
8M
F4
F2
F3
F4
F5
F6
F7
F8
D1 D2 D3 D4 D5 D6 D7 D8
IPX10:4
IPX10:4
IPX10:4
IPX10:8
IPX10:8
LF
HF
LF
HF
IPX10:4
Delay
LF
HF
S
S
LF
HF
LF
HF
IPX10:4
IPX10:4
LF
F1
DJ Monitor
Fill
1250/8 1250/8 1250/8 1250/8
1250/4
1250/4
1250/4
F3
F4
F5
S
F6
F7
IPX10:4
F8
CITY HALL
S
Main 1
Main 2
2500/4 2500/4
2500/4 2500/4
Side 1&2
2500/4
Subwoofer
Delay
2500/4
1250/4
2500/4
Left
Right
1250/8
1250/8
Fill
1250/4
100 V
1300/2
T
S
T
F1
F2
F3
F4
LF
HF
LF
HF
LF
HF
LF
HF
LF
HF
LF
HF
S
S
S
S
S
S
S
S
S
S
S
S
LF
HF
LF
HF
...
Subwoofer
5000/4
5000/4
5000/4
5000/4
5000/4
1 1
5000/4
5000/4
5000/4
IPX10:8
IPX10:8
1250/4
City Hall
5000/4
F2
S
D1 D2 D3 D4 D5 D6 D7 D8
Club
5000/4
HF
5000/4
5000/4
3
4
5
6
7
8
IPX10:8
IPX10:4
IPX10:4
IPX10:4
IPX20:4
IPX20:4
IPX10:8
IPX20:4
PERFORMING ARTS CENTER
Performing Arts Center / Theater
IPX10:4
Left
Fill
Center
Right
TRIBUNES
Cluster 3
Delay
Cluster 4
Cluster 5
Cluster 6
Cluster 7
LF
HF
S
S
LF
HF
LF
HF
IPX10:4
IPX10:4
Cluster 8
Upper
LF
HF
S
S
LF
HF
LF
HF
IPX10:4
Middle
IPX10:4
Lower
LF
UNDER BALCONY 70/100 V
B
A
A
B
A
B
A
B
A
FIELD
Field 2
Field 3
S
S
IPX10:4
B
F1
Field 1
HF
F2
F3
F4
F5
F6
F7
F8
D1 D2 D3 D4 D5 D6 D7 D8
IPX10:4
IPX10:4
City Hall
IPX10:4
IPX10:8
Field 4
4U
4L
3M
UBA
3U
3L
4M
UBB
6U
6L
5M
F1
5U
5L
6M
F2
8U
8L
7M
F3
7U
7L
8M
F4
IPX10:4
IPX10:4
IPX10:4
IPX10:8
TECHNICAL SPECIFICATIONS
Amplifier model
OUTPUT POWER
Low-Z mode: Load Impedance
Maximum Output Power 1
Normal Mode, all channels driven
Bridged
Parallel
2Ω
2.7 Ω
4Ω
8Ω
2Ω
2.7 Ω
4Ω
8Ω
2Ω
2.7 Ω
4Ω
8Ω
2Ω
2.7 Ω
1300 W
2500 W
1500 W
3000 W
1250 W
2600 W
2500 W
1250 W
2500 W
1250 W
2600 W
5000 W
3000 W
4000 W
2500 W
5200 W
2500 W
1250 W
5000 W
1250 W
1300 W
2500 W
1500 W
3000 W
1250 W
2600 W
2500 W
1250 W
2500 W
1250 W
5200 W
6000 W
Parallel-Bridged
2500 W
6000 W
5000 W
5000 W
10400 W
12000 W
10000 W
5000 W
5200 W
6000 W
5000 W
5000 W
70 V
100 V
140 V 2
200 V 2
70 V
100 V
140 V 2
200 V 2
70 V
100 V
140 V 2
200 V 2
70 V
100 V
1250 W
1250 W
2500 W
2500 W
2500 W
2500 W
5000 W
5000 W
1250 W
1250 W
2500 W
2500 W
3550 W
5000 W
Direct Drive mode: Nominal
Voltage
Maximum Output Power
Number of amplifier channels
Maximum Output Voltage
normal mode, per channel
Maximum Output Current
normal mode, per channel
AMPLIFIER
Voltage Gain
Low-Z mode, ref. 1 kHz
Direct Drive mode
Input Sensitivity
Low-Z mode, ref. to Max. Output
Voltage
Direct Drive mode
THD
3dB below max., AES17, 1kHz
IMD-SMPTE
60 Hz, 7 kHz
DIM100
3.15 kHz, 15 kHz
Crosstalk
ref. 1 kHz, 12 dB below Max., 8 Ω
Frequency Response
ref. 1 kHz, analog in to speaker out
Damping Factor
20 Hz to 200 Hz, 8 Ω
Output Stage Topology
Signal to Noise Ratio Amplifier
A-weighted, analog input
A-weighted, digital input
Output Noise
A-weighted, analog input
A-weighted, digital input
DIGITAL SIGNAL PROCESSING
Sampling rate
Signal Delay / Latency
analog in to Speaker Out,
48 kHz / 96 kHz
Dante Network Latency
Signal Processing
User EQ
User Delay
Array EQ
Array Delay
Speaker EQ
Speaker X-Over
Speaker FIR
Speaker Limiters
Other Functions
1
IPX5:4
4
IPX10:4
IPX10:8
4
8
150 V peak
41 A peak
IPX20:4
4Ω
8Ω
5000 W
2500W
5000 W
-
n.a.
10000 W
8000 W
n.a.
140 V
5000 W
4
210 V peak
53 A peak
41 A peak
84 A peak
32.0 dB, adjustable 20.0 - 44.0 dB
33.2 / 36.2 / 39.2 / 42.2 dB for 70 / 100 / 140 / 200 V
10.7 dBu (2.66 V), adjustable -1.3 - 22.7 dBu
13.7 dBu (3.73 V), adjustable 1.7 - 25.7 dBu
6 dBu (1.55 V), fixed
< 0.05 %
< 0.05 %
< 0.15 %
< 0.15 %
< -80 dB
20 Hz to 20 kHz (±0.5 dB)
20 Hz to 20 kHz (±1 dB)
> 400
Class D, fixed frequency
112 dB
115 dB
115 dB
118 dB
< -70 dBu
< -73 dBu
48 kHz / 96 kHz, OMNEO/Dante synchronized
0.70 ms / 0.53 ms
typ. 1.00 ms
32/40 bit, floating point
12 filters per channel, selectable as PEQ, Lo-Shelv, Hi-Shelv, Lo-ShelvQ, Hi-ShelvQ, Hi-Pass, Lo-Pass and Notch; 2 filters with additional asymmetric filter type
0 to 2000 ms per channel (units: µs, ms, s, cm, m, inches, feet)
5 filters per channel, selectable as PEQ, Lo-Shelv, Hi-Shelv, Hi-Pass, Lo-ShelvQ, Hi-ShelvQ, Lo-Pass and All-Pass
0 to 500 ms per channel (units: µs, ms, s, cm, m, inches, feet)
10 filters per channel, selectable as PEQ, Lo-Shelv, Hi-Shelv, Hi-Pass, Lo-Pass and All-Pass
Hi-Pass and Lo-Pass per channel, 6/12/18/24/30/36/42/48 dB Bessel/Butterworth, 12/24/48 dB Linkwitz-Riley; Alignment Delay, 0 to 20 ms per channel
up to 1025 taps, Linear Phase Filter, Linear Phase Brickwall X-Over
Peak Anticipation Limiter and RMS/TEMP Limiter per channel
Source Selection and Mix, Level, Mute, Polarity, Sine and Noise Generator, Pilot Tone Generator and Detection, Level Meters, Impedance Measurement and Load Monitoring
Amplifier model
DIGITAL SIGNAL PROCESSING
Memory
DSP Presets
Speaker-Pool Presets
Source Supervision and Fallback
CONNECTIVITY
Analog Audio Input / Thru
Type
Maximum Input Level
Input Impedance, active balanced
Reference level equal to digital input
Network
Type
General
Network Audio Inputs
Network Audio Outputs (Monitor)
Mains Input
Speaker Output
GPIO Control Port
Type
Ports and Operating Modes
Analog Input Range
Digital Input Limits
Digital Outputs
Reference Voltage Output
READY/FAULT contact
GENERAL
User Interface
Display
Front panel indicators
Front panel operating elements
Rear panel indicators
Rear panel operating elements
Power Requirements
Power Consumption
Rated power consumption
(see BTU table)
IPX5:4
IPX10:4
2 x 6-pin Euroblock, male
4 x 6-pin Euroblock, male
2 x 6-pin Euroblock, male
+21 dBu
20 kΩ
+21 dBu for 0 dBFS
2 x Neutrik etherCON
1000base-T / 100base-TX, integrated switch
8 channels, 48/96 kHz, OMNEO/Dante format
2 channels, 48/96 kHz, OMNEO/Dante format
1 x Neutrik powerCON-HC
2 x 8-pin Euroblock, 6mm, female
1 x 8-pin Euroblock, 6mm, female
1 x 8-pin Euroblock, 6mm, female
1 x 8-pin Euroblock, male
3 x GPIO, switchable Analog In / Digital In / Digital Out
0 V to +13 V, 40 kΩ input resistance
ON: < 1.5 V / OFF: > 2.0 V, internal Pull Up (10 kΩ)
ON: Output switched to GND, max. 200 mA
OFF: Open Collector (40 kΩ to GND)
+10 V, max. 200 mA, supervised, short circuit protected
galvanic isolated relay, max. 30 VDC / 500 mADC
OLED 256 x 64
4 x status LEDs (POWER, STANDBY, FAULT, OMNEO)
3 buttons (UP, ENTER, DOWN)
1 x status LED (STATUS)
Mains Switch
100 V to 240 V, 50 Hz to 60 Hz AC
900 W
75 W
< 15 W
Protections
Cooling
Ambient Temperature Limits
IEC Protection Class
Electromagnetical Environment
Color
Dimensions, (W x H x D), mm
Weight
Shipping Weight
Ordering Code
IPX20:4
5 Factory + 20 User
30 Speaker Settings
Pilot Tone supervision at Analog and OMNEO/Dante inputs, switchover to alternative Source Selection
700 W
1/8 Maximum Output Power at 4 Ω
Idle Mode (no input signal)
Standby Mode
Power Supply Topology
IPX10:8
14.3 kg (31.5 lb)
16.5 kg (36.4 lb)
F.01U.329.709
1200 W
1300 W
2250 W
1765 W
1780 W
80 W
105 W
< 16 W
< 18 W
Switching Mode Power Supply with digital controlled Power Factor Correction
Audio Limiters, High Temperature, DC, HF, Short Circuit, Back-EMF, Peak Current Limiters, Inrush Current Limiters, Turn-on Delay,
Mains Circuit Breaker Protection, Mains Over-/Undervoltage Protection
Front-to-rear, temperature controled fans, supervised
+5 °C to +40 °C (+40 °F to +105 °F)
Class I (grounded)
E1, E2, E3
Black
483 x 88.1 x 514
15.0 kg (33.0 lb)
16.8 kg (37.1 lb)
17.2 kg (37.8 lb)
19.1 kg (42.1 lb)
F.01U.329.712
F.01U.329.715
2850 W
110 W
< 19 W
18.3 kg (40.3 lb)
20.5 kg (45.1 lb)
F.01U.329.718
Amplifier at rated conditions, Low-Z Normal operation mode, all channels driven, 4 Ω loads, Analog input, 32 dB Gain, 48 kHz sample rate, unless otherwise specified.
1
Test signal for max. output power according IHF-A-202 (Dynamic-Headroom, burst 1 kHz / 20 ms on / 480 ms off / low level -20 dB)
2
Available in Bridged ration mode only.
Subject to change without prior notice.
Headquarter Addresses
North America Global HQ
Bosch Security Systems, Inc.
Burnsville, MN
+1-952-884-4051
©2018 Bosch Security Systems, Inc.
Latin America Regional HQ
Robert Bosch, Limitada
Security Systems
Campinas, SP, Brasil
+55 19 2103-4282
Asia Pacific Regional HQ
Robert Bosch (SEA) Pte Ltd
Singapore
+65 6571 2808
China Regional HQ
Bosch (Shanghai)
Security Systems Ltd.
IBP, Changning District
Shanghai, P.R. China
400-8310-669
Europe Regional HQ
Bosch Sicherheitssysteme
GmbH
(EVI Audio GmbH)
Straubing, Germany
+49 9421 706-0
Download PDF
Similar pages