Body Jet Fitting Instructions &

AFTERCARE INSTRUCTIONS
Your fitting has a high quality finish and should be treated with care to
preserve the visible surfaces.
All surface finishes will wear if not cleaned correctly, the only safe way
to clean your fitting is to wipe with a soft damp cloth. Stains can be
removed using washing up liquid. All bath cleaning powders and
liquids will damage the surface of your fitting even the non-scratch
cleaners.
GUARANTEE
All products are manufactured to the highest standards and a 5 year
guarantee covers any defect in manufacture.
As gold and special effect finishes are softer than chromium plate,
special care must be taken when cleaning; a 3 year guarantee covers
these finishes.
NOTE: - the 5 year guarantee is invalidated if damaged by any
waterborne debris.
In the interests of continuous product development we reserve the right to alter specification
as necessary
PRODUCT CODE: JET2 C / JET3 C
Body Jet
TELEPHONE HELP LINE! +44 (0) 870 4425553
Bristan Limited
Birch Coppice Business Park
Dordon
Tamworth
Staffordshire
B78 1SG
UK
Fitting
Instructions
& Content list
Web site: www.bristan.com
Telephone:
+44 (0) 870 4425556
Facsimile:
+44 (0) 870 4425554
Email:
enquire@bristan.com
(FI JET2/3)
(Rev. D1)
(B)
Please keep these instructions for future reference and request of
replacement parts
Body jets are intended to be used in conjunction with other products,
such as the blending valve, diverters and stopcocks from the Bristan
pick and mix ranges in order to create a system to suit your
requirements.
INSTALLATION DIAGRAM
COMPONENTS
1.
2.
3.
Body jet
Cover plate
Tee connector (not supplied)
INSTALLATION
Body jets should be arranged in your system to provide the necessary
spray outlets to suit the application.
1.
Identify all components and check for completeness, particularly
before arranging fitting.
2.
Depending on application the body jet can be panel mounted
using a backnut (not supplied) or set into the wall on rigid pipe
work. If panel mounting care should be taken to ensure
connection can be made after securing with the backnut.
3.
Multiple body jets will require installation in parallel using a pressurebalancing loop, as shown below:
Connect body jet to pipe work using recommended ½” BSP
connections (not provided) with thread sealing compound where
necessary.
NOTE: - Before finishing wall turn on water supplies to check
both correct system function and for leaking from
joints/connections.
MAINTENANCE
4.
Complete wall finish.
If the fitting begins to drip
5.
See over the page for aftercare instructions.
1.
2.
3.
4.
5.
Turn off the water supply.
Unscrew face plate and remove nozzle.
Carefully clean seating, rubber seal and nozzle.
Replace rubber seal, nozzle and screw on face plate.
Contact our help line if problem persists.
Bristan recommend E-Cloth for cleaning all of our
bathroom & kitchen products. Using just water, E-cloth
gives a smear free, deep clean by breaking up and holding
dirt, which normal cloths leave behind. Order through
your Bristan stockist. (ORDER CODE: ECLOTH)
GUARANTEE
All products are manufactured to the highest standards and a 5 year guarantee
covers any defect in manufacture.
All products must have access for servicing or replacement during the life of
the product.
In the interests of continuous product development we reserve the right to alter
specification as necessary
Ceiling Fed Shower Arm
THIS BOOKLET COVERS PRODUCT CODES:
ARM CFRD01 C
ARM CFSQ01 C
ARM CFRD02 C
ARM CFSQ02 C
Fitting Instructions
TELEPHONE HELPLINE: 0844 701 6273
Bristan Group Limited
Birch Coppice Business Park
Dordon
Tamworth
Staffordshire
B78 1SG
UK
A Masco Company
Website: www.bristan.com
Telephone: 0844 701 6274
Facsimile: 0844 701 6275
Email: enquire@bristan.com
(FI ARMCF)
(REV D3)
Please keep these instructions for future reference
This shower arm is intended to be used in conjunction with other
products, such as shower or blending valves, diverters and
stopcocks from the Bristan ranges in order to create a system to suit
your requirements.
G 1/2”
COMPONENTS
1.
2.
3.
4.
Backnut
Locknut
Shroud
Shower Arm
1
2
3
INSTALLATION
*Dimensions may vary
The shower arm should be arranged to accept a supply of flow
controllable mixed water.
4
1. Identify all components and check for completeness before
arranging fitting.
2. The shower arm (4) should be secured using the backnut (1) and
the locknut (2) (where supplied).
3. The shower arm (4) should be secured using the backnut (1) and
the locknut (2).
G 1/2"
3. Rigid pipework should be used to support the arm, via a female
G 1/2” BSP to 15/22mm compression adaptor, (not supplied).
NOTE: Before finishing ceiling, turn on water to supplies to check for
leaks at connections.
4. Connect arm to supply using thread sealing compound where
Necessary.
5. Complete ceiling finish and slide shroud (3) up to ceiling.
AFTERCARE INSTRUCTIONS
Your fitting has a high quality finish and should be treated with care to
preserve the visible surfaces.
All surface finishes will wear if not cleaned correctly, the only safe way
to clean your mixer is to wipe with a soft damp cloth. Stains can be
removed using washing up liquid. All bath cleaning powders and liquids
will damage the surface of your fitting, even the non-scratch cleaners.
NOTE: Never use abrasive detergents or disinfectants or those
containing alcohol, hydrochloric acid or phosphoric acid.
Bristan recommend E-Cloth for cleaning all of our
bathroom & kitchen products. Using just water, E-cloth
gives a smear free, deep clean by breaking up and holding
dirt, which normal cloths leave behind. Order through
your Bristan stockist. (ORDER CODE: ECLOTH)
GUARANTEE
All products are manufactured to the highest standards and a 5 year guarantee
covers any defect in manufacture.
All products must have access for servicing or replacement during the life of
the product.
In the interests of continuous product development we reserve the right to alter
specification as necessary
THIS BOOKLET COVERS PRODUCT CODES:
FH SLRD01 C FH SLSQ01 C
FH SLRD02 C FH SLSQ02 C
FH SLRD03 C FH SLSQ03 C
Slim Line Square/Round
Fixed Shower Head
Fitting Instructions
TELEPHONE HELPLINE: 0844 701 6273
Bristan Group Limited
Birch Coppice Business Park
Dordon
Tamworth
Staffordshire
B78 1SG
UK
A Masco Company
Website: www.bristan.com
Telephone: 0844 701 6274
Facsimile: 0844 701 6275
Email: enquire@bristan.com
(FI FH SL)
Please keep these instructions for future reference.
(REV D1)
This shower rose is intended to be used in conjunction with other products, such
as a shower arm and valve.
INSTALLATION DIAGRAM
INSTALLATION
This shower head should be arranged in your system with a supply of pre-mixed
water from a shower valve.
This product is designed to be fitted to shower arms with a male ½”BSP thread. If
replacing a shower rose, simply unscrew the current one and fit the new rose. The
shower rose comes with a swivel joint, so the rose can be positioned as desired.
Tighten by hand ONLY. Check joint and connections for any leaks, if this occurs
check the condition of the washer. Replace if necessary or reseat correctly then
re-tighten.
In order to maintain optimum spray, we advise that the shower rose face plate
be regularly cleaned, particularly in hard water areas.
FH SLSQ01 C
FH SLSQ02 C
FH SLSQ03 C
200mm x 200mm
250mm x 250mm
300mm x 300mm
AFTERCARE INSTRUCTIONS
FH SLRD01 C
FH SLRD02 C
FH SLRD03 C
200mm diameter
250mm diameter
300mm diameter
Your fitting has a high quality finish and should be treated with care to preserve the
visible surfaces.
All surface finishes will wear if not cleaned correctly, the only safe way to clean your
mixer is to wipe with a soft damp cloth. Stains can be removed using washing up
liquid. All bath cleaning powders and liquids will damage the surface of your fitting,
even the non-scratch cleaners.
NOTE: Never use abrasive detergents or disinfectants or those containing
alcohol, hydrochloric acid or phosphoric acid.
Installation Instructions
and User Guide
Thermostatic Recessed
Three Control Shower
Valve with Stopcock &
Two outlet Diverter
Models covered: CAS SHC3DIV C,
PM2 SHC3DIV C, TRI SHC3DIV C,
PIV SHC3DIV C, ORB SHC3DIV C,
GLR SHC3DIV C, BRG SHC3DIV C,
DSC SHC3DIV C, HOU SHC3DIV C &
SAI SHC3DIV C
Please keep this booklet for future
reference.
Installer, when you have read these
instructions please ensure you leave
them with the user.
Contents
Thank you for choosing Bristan, the UK’s leading showers and taps expert. We have
designed this product with your enjoyment in mind. To ensure that it works to its full
potential, it needs to be fitted correctly. These fitting instructions have been created to
give you all of the information you need and, if you need any further help, please do not
hesitate to give us a call on 0844 701 6273.
Important Safety Information …………………………………………………..………….. 3
General Information ……………………………………………………………………………..4
Product Features …………………………………………………………………………………. 5
Specifications ………………………………………………………………………………………. 6
Dimensions ………………………………………………………………………………….………. 7-9
Pack Contents ……………………………………………………………………………………… 10-16
Prior to Installation …………………………………………………………..………............ 17
Installation …………………………………………………………………………………..………. 18-22
Front Access …………………………………………………..……................
18-19
Rear Access .…………………………………………………………….………….
20-21
Wall Outlet …………………………………………………………………………… 22
Operating the Shower ………………………………………………………………….………. 23
Maintenance ………………………………………………………………………………..………. 24
Adjusting the Temperature ………………………………………………………………….. 25
Troubleshooting …………………………………………………………………………..………. 26-27
Notes …………………………………………………………………………………………………...
30-31
Guarantee ……………………………………………………………………………………………..
2
28-29
Need help? Give us a call on 0844 701 6273 and speak to one of our trained advisers.
Important Safety Information
• Please read these instructions thoroughly and retain for future use.
• All products manufactured and supplied by Bristan are safe provided they are
installed, used correctly and receive regular maintenance in accordance with these
instructions.
• If you are in any doubt about your ability to install this product safely you must
employ the services of an experienced qualified plumber.
• These fittings need to be installed in accordance with, and meet the requirements of
the Water Supply (Water Fittings) Regulations 1999 and Scottish Byelaws 2004.
• Remove all packaging and check there are no missing or damaged parts.
• Before starting any installation please consider the following:
• Before drilling into walls, check that there are no hidden electrical wires, cables or
water supply pipes. This can be checked with the aid of an electronic detector.
• If power tools are used do not forget to:
- Wear eye protection
- Unplug equipment after use
•
Warning: Before installing the new shower valve it is essential that you thoroughly
flush through the pipework in order to remove any remaining swarf, solder, etc. Failure
to carry out this procedure could cause problems or damage to the workings of the
shower valve.
• Fitting isolation valves to the inlet feeds is required for ease of maintenance.
• Access must be made available to the shower valve / mixer body for maintenance /
servicing purposes.
•
Warning: Do not operate this product if you suspect it is frozen. Do not site the
Mixing Valve where it might be subjected to freezing conditions.
• These shower valves must not be modified in any way as this will invalidate the
guarantee.
Need help? Give us a call on 0844 701 6273 and speak to one of our trained advisers.
3
General Information
This product has been tested to the Water Regulations Advisory Scheme (WRAS) and
satisfies the requirements of the Water Supply (Water Fittings) Regulations 1999 and
current bylaws.
For full Installation Requirements & Notes (IRN) please visit www.wras.co.uk/directory.
BS7600 recommends the temperature of stored water should never exceed 65ºC. A
stored water temperature of 60ºC is considered sufficient to meet all normal
requirements and will minimise the build up of lime scale in hard water areas.
If the shower valve is installed at low pressure (tank fed), then the minimum distance
from the highest installed position of the showerhead to the underside of the cold tank
should be at least 1 metre to ensure adequate performance.
Note: Nominally equal (balanced) inlet supply pressures are recommended for optimum
performance.
This shower valve should be installed in compliance with the Water Supply (Water
Fittings) Regulations1999 and the Scottish Bylaws 2004.
If in doubt, contact a registered plumber or your Local Water Authority or the Secretary
of The Institute of Plumbing, address as follows;The Institute of Plumbing,
64 Station Lane,
Hornchurch,
Essex,
RM12 6NB
Tel: 01708 472791
Recommended Usage
4
Domestic
Heavy
Commercial
Light
Commercial
Health Care
Need help? Give us a call on 0844 701 6273 and speak to one of our trained advisers.
Product Features
1. Two outlet diverter
This outlet allows the user to divert the
flow of water from one water outlet to
another. E.g. Fixed rigid riser or an
adjustable riser.
1
2. Temperature control
Adjustable temperature control.
Turn the handle clockwise for a cooler
temperature.
2
Turn the handle anti-clockwise for a hotter
temperature.
3. Single outlet stopcock
Allows the user to operate another water
outlet e.g. body jets while one outlet from
the top diverter is also being used.
3
This outlet also allows the user to use this
outlet independantly.
Note: Both the bottom stopcock and one
of the top diverter outlets can be used
together. If both of these outlets are used
together the flow will be shared between
both outlets.
CAS SHC3DIV C shown
Need help? Give us a call on 0844 701 6273 and speak to one of our trained advisers.
5
Specifications
Inlet connections: 15mm compression with 150mm between centres.
Minimum working pressure: 0.2 bar
Note: This product has been designed to deliver a high flow of water on low pressure
systems, however depending on the installation, type of system and shower accessories
used, a higher pressure maybe required to optimise the showering experence.
Maximum working pressure: 5 bar
Maximum static pressure: 10.0 bar
Note: Static pressure is the build up of pressure when the valve is closed.
Supply requirements:
Minimum cold water supply temperature: 5ºC.
Maximum cold water supply temperature: 25ºC.
Maximum hot water supply temperature: 80ºC.
Note: The inlet hot water temperature must be at least 10ºC above the required blend
temperature (e.g. shower temperature 43ºC: minimum hot water temperature 53ºC).
System requirements:
Gravity fed hot & cold (Equal pressures)
Gravity fed hot & mains cold (Differential pressure, maximum ration 5:1)
Unvented systems
Instantaneous water heater (Combination boiler)
Pumped system
Note: When using a pumped system we recommend that an essex flange is used.
Important: Minimum wall cavity depth: 35mm
6
Need help? Give us a call on 0844 701 6273 and speak to one of our trained advisers.
Pack Contents - CAS SHC3DIV C
1
1. Concealing plate x1
2
2. Valve body x1
3. Handles x3
4. Shroud extension screws x3
5. Shroud extensions x3
6. Valve body fixings x4/4
7. Inserts x2
8. Flow regulators x2
9. Filter washers x2
10. Wall outlet
6
3
4
9
8
5
7
10
Need help? Give us a call on 0844 701 6273 and speak to one of our trained advisers.
7
Pack Contents - PM2 SHC3DIV C
1. Concealing plate x1
2. Valve body x1
1
3. Handles x3
2
4. Extension screws x3
5. Spline adaptors x3
6. Valve body fixings x4/4
7. Inserts x2
8. Flow regulators x2
9. Filter washers x2
10. Wall outlet
6
3
5
4
10
9
8
7
8
Need help? Give us a call on 0844 701 6273 and speak to one of our trained advisers.
Pack Contents- TRI SHC3DIV C
1
1. Concealing plate x1
2
2. Valve body x1
3. Handles x3
4. Extension screws x3
5. Spline adaptors x3
6. Valve body fixings x4/4
7. Inserts x2
8. Flow regulators x2
9. Filter washers x2
10. Wall outlet
6
5
4
3
10
9
8
7
Need help? Give us a call on 0844 701 6273 and speak to one of our trained advisers.
9
Pack Contents - PIV SHC3DIV C
1
1. Concealing plate x1
2
2. Valve body x1
3. Handles x3
4. Extension screws x3
5. Spline adaptors x3
6. Valve body fixings x4/4
7. Inserts x2
8. Flow regulators x2
9. Filter washers x2
10. Wall outlet
6
5
4
3
10
9
8
7
10
Need help? Give us a call on 0844 701 6273 and speak to one of our trained advisers.
Pack Contents - ORB SHC3DIV C
2
1
1. Concealing plates x3
2. Valve body x1
3. Handles x3
4. Extension screws x3
5. Spline adaptors x3
6. Valve body fixings x4/4
7. Inserts x2
8. Flow regulators x2
9. Filter washers x2
10. Wall outlet
6
5
4
3
10
9
8
7
Need help? Give us a call on 0844 701 6273 and speak to one of our trained advisers.
11
Pack Contents - GLR SHC3DIV C
1
1. Concealing plate x1
2
2. Valve body x1
3. Handles x3
4. Shroud extension screws x3
5. Shroud extensions x3
6. Valve body fixings x4/4
7. Inserts x2
8. Flow regulators x2
9. Filter washers x2
10. Wall outlet
6
3
4
9
8
5
7
10
12
Need help? Give us a call on 0844 701 6273 and speak to one of our trained advisers.
Pack Contents - BRG SHC3DIV C
1. Concealing plate x1
1
2
2. Valve body x1
3. Handles x3
4. Extension screws x3
5. Spline adaptors x3
6. Valve body fixings x4/4
7. Inserts x2
8. Flow regulators x2
9. Filter washers x2
10. Wall outlet
6
5
4
3
10
9
8
7
Need help? Give us a call on 0844 701 6273 and speak to one of our trained advisers.
13
Pack Contents - DSC SHC3DIV C
1. Concealing plate x1
2. Valve body x1
1
3. Handles x3
2
4. Extension screws x3
5. Spline adaptors x3
6. Valve body fixings x4/4
7. Inserts x2
8. Flow regulators x2
9. Filter washers x2
10. Wall outlet
6
3
5
4
10
9
8
7
14
Need help? Give us a call on 0844 701 6273 and speak to one of our trained advisers.
Pack Contents - HOU SHC3DIV C
1
1. Concealing plate x1
2. Valve body x1
2
3. Handles x3
4. Extension screws x3
5. Spline adaptors x3
6. Valve body fixings x4/4
7. Inserts x2
8. Flow regulators x2
9. Filter washers x2
10. Wall outlet
6
5
3
4
10
9
8
7
Need help? Give us a call on 0844 701 6273 and speak to one of our trained advisers.
15
Pack Contents - SAI SHC3DIV C
1. Concealing plate x1
1
2. Valve body x1
2
3. Handles x3
4. Extension screws x3
5. Spline adaptors x3
6. Valve body fixings x4/4
7. Inserts x2
8. Flow regulators x2
9. Filter washers x2
10. Wall outlet
6
5
3
4
10
9
8
7
16
Need help? Give us a call on 0844 701 6273 and speak to one of our trained advisers
Prior to Installation
Flow Regulators
This shower valve is supplied with a 5 and
7 litre per minute flow regulator loose in
the box which must be fitted if the shower
valve is installed in conjunction with an
instantaneous water heater / combination
boiler.
With both flow regulators fitted and by
turning the water heater / combination
boiler to its hottest setting, will ensure a
sufficiently hot water supply to the shower
valve during winter months (in the UK),
when the mains cold water supply is at its
coldest.
To fit the flow regulators
Remove the inlet elbows ensuring the
filter washer is also removed. carefully
remove the plastic inserts from the valve
inlets and push in the flow regulators. The
green 7 litre per minute flow regulator
must be fitted to the cold inlet and the
yellow 5 litre per minute flow regulator
must be fitted to the hot inlet.
Filter
Washer
Elbow
Insert
Place the filter washers back into the
elbow nuts and tighten the nuts fully onto
the outlets.
In the event that this shower valve is not
installed with an instantaneous water
heater / combination boiler, the flow
regulators do not need to be fitted.
Flow
Regulator
Need help? Give us a call on 0844 701 6273 and speak to one of our trained advisers.
17
Installation - Front Access
Front access installation is designed for
installations where a recessed valve is
already installed in the wall cavity and is to
be replaced.
Important: Water supplies to the mixer
must be with hot on the left and cold on
the right when viewed from the front.
Wall plugs
Before Installation
Flush through the pipework to ensure
removal of any debris. Turn off the mains
water supply and close any isolating
valves.
1. Attach shower valve to wall
Place the shower valve in the required
position and mark the centres of the fixing
holes onto the wall.
Warning: Please check for any hidden
pipes and cables before drilling holes in
the wall.
Fixing
screws
Drill suitable holes and insert the wall
plugs. Securely attach the shower valve to
the wall using the screws supplied.
Important: The ORB SHC3DIV C can be
installed either portrate or landscape.
The TRI SHC3DIV C must be installed
landscape. The hot water inlet must be at
the bottom with the cold water inlet at the
top.
Elbow
2.Connect water supply pipes
Insert 15mm hot and cold water supply
pipes into the inlet connections and
tighten nuts, ensuring the olives are fitted.
3. Plumb in outlets
Insert 15mm pipework into the top and
bottom outlets and plumb into the users
chosen products. Ensure the olives are
fitted when tightening the nuts.
18
Olive
Bottom
Outlet
Compression
nut
Need help? Give us a call on 0844 701 6273 and speak to one of our trained advisers.
Installation - Front Access
4. Fit concealing plate
Note: The concealing plate can be used
as a template by drawing around the plate
and measuring in by 10mm to give
sufficient clearance.
See page 18 for concealing plate
adjustment.
Run a bead of waterproof silicon sealant
around the inner edge of the concealing
plate.
Slide the concealing plate onto the shower
valve control handles and apply firm
pressure to ensure to silicon sealant
spreads.
5. Fit Handles
Push the spline adaptors (if required) onto
the valve spindles.
Push the handles onto the spline adaptors
and secure by tightening the grub screw
and push-fit the cap into position.
Concealing plate
Need help? Give us a call on 0844 701 6273 and speak to one of our trained advisers.
19
Installation - Rear Access
This installation method should be used to install the CAS, TRI, PIV, GLR,
BRG & ORB SHC3DIV C
Rear access installation is designed for
new installations where there is no
shower valve already installed. Once the
shower valve is secured in the wall cavity
the wall should be finished and tiled.
Rear
Access
Access is required from the rear for future
servicing of the shower valve filters. The
cartridge can be accessed from the front.
Before Installation
Flush through the pipework to ensure
removal of any debris. Turn off the mains
water supply and close any isolating
valves.
Batton
1. Install shower valve
Install suitable battons (if required) onto
the rear cavity wall. Place the shower
valve in the required position and mark the
fixing holes.
Drill suitable holes and insert the wall
plugs (if necessary). Securely attach the
shower valve to the wall / battons using
the screws supplied.
2.Connect water supply pipes
Insert 15mm hot and cold water supply
pipes into the inlet connections and
tighten nuts, ensuring the olives are fitted.
3. Plumb in outlets
Insert 15mm pipework into the top and
bottom outlets and plumb into the users
chosen products. Ensure the olives are
fitted when tightening the nuts.
Important: The ORB SHC3DIV C can be
installed either portrate or landscape.
If the valve is installed landscape the hot
water inlet must be at the bottom with the
cold water inlet at the top.
20
Batton
Front of
Cavity
Rear of
Cavity
Important: Cascade, Tria, Pivot and
Orb all require installing with rear
access to allow for future serving
and maintenance of the filters. The
cartridge can be accessed from the
front.
Need help? Give us a call on 0844 701 6273 and speak to one of our trained advisers.
Installation - Rear Access
4. Finish wall surface
Plasterboard and tile the cavity wall
ensuring there is a gap between the tiles
and the shower valve
5. Fit concealing plate and handles
Run a bead of waterproof silicon sealant
around the inner edge of the concealing
plate.
Slide the concealing plate onto the shower
valve and apply firm pressure to ensure to
silicon sealant spreads.
6. Fit handles
Push the spline adaptors onto the valve
spindles.
Plaster
board
Push the handles onto the spline adaptors
and secure by tightening the grub screw
and push-fit the cap into position.
Tile
7. Create rear access
Rear access to the shower valve is
required to enable the shower to be
maintained and serviced. Cut out the rear
plasterboard in the back of the wall cavity
to create accress. A piece of plasterboard
or a panel maybe used to cover the access
hole but must be removable.
Batton
Removable
Access Panel
Need help? Give us a call on 0844 701 6273 and speak to one of our trained advisers.
21
Installation - Wall Outlet
Fitting the Wall Outlet
There are two methods of fixing the wall
outlet depending on the type of wall:
a: With rear access once wall finished
Fit the rubber washer to the back of the
wall outlet, place the assembly through a
25-30mm hole in the wall and secure with
the backnut ensuring the washer is fitted
between the backnut and the wall.
Backnut
Washer
Wall
Wall
outlet
Connect the wall outlet assembly to the
shower valve outlet.
b: Without rear access once wall finished
Fit a ‘1/2” female connection’ (not
supplied) within the wall cavity and plumb
in from the shower valve. Screw the wall
outlet into the ‘1/2” female connection’
using a suitable thread sealant ensuring
the rubber seal is fitted to the back of the
wall outlet.
Note: The backnut and washer are not
required.
Rubber
seal
Female
fitting
Rubber
seal
Wall
Wall
outlet
22
Need help? Give us a call on 0844 701 6273 and speak to one of our trained advisers.
Operating the Shower
1. Two outlet diverter
This outlet allows the user to divert the
flow of water from one product to another.
1
Turn the handle one way or the other to
turn the flow of water on to your chosen
product.
To turn the flow of water off turn the
handle back to the centre.
2. Temperature control
Adjustable temperature control.
Turn the handle clockwise for a cooler
temperature.
2
Hot
Turn the handle anti-clockwise for a hotter
temperature.
3. Single outlet stopcock
Cold
Allows the user to operate a product while
one outlet from the top diverter is also
being used.
Turn the handle anti-clockwise to turn the
flow of water on.
Turn the handle back to the centre to turn
the flow of water off.
3
On
Off
Need help? Give us a call on 0844 701 6273 and speak to one of our trained advisers.
23
Maintenance
General Cleaning
Your fitting has a high quality finish and
should be treated with care to preserve
the visible surfaces. All surfaces will wear
if not cleaned correctly, the only safe way
to clean your product is to wipe with a soft
damp cloth. Stains can be removed using
washing up liquid. All bath cleaning
powders and liquids will damage the
surface of your fitting, even the
non-scratch cleaners.
2. Unscrew the cartridge anti-clockwise
and remove from the valve body.
Unscrew
anti-clockwise
to remove
Note: Never use abrasive detergents or
disinfectants or those containing alcohol,
hydrochloric acid or phosphoric acid.
Bristan recommend E-cloth for
cleaning all of our bathroom
& kitchen products. Using just
water, E-cloth gives a smear
free, deep clean by breaking up and holding dirt, which normal cloths leave
behind. Order through your Bristan
stockist (order code: ECLOTH).
Cartridge Maintenance
We advise that the shower valve is
regularly serviced in hard water areas to
maintain the flow of water.
Tighten
clockwise
to replace
3. Remove the piston and thermostat
assembly and place into a bowl.
Carefully add hot water (just off the boil)
and vinegar to de-scale. Leave in the
solution until the water has cooled and
rinse with clean water.
Piston
Isolate both hot and cold water supplies to
the shower valve by either:
• Turning the water supply off at the
mains stopcock or
• Turning off the isolation valves to the
shower valve.
Thermostat
1. Remove the temperature handle and
plastic stop.
4. Grease the seals with a silicon grease
supplied by Bristan (part number: SP-4950002) and carefully refit.
Important: Take note of the position
of the plastic stop and handle - They must
be refitted in the same position.
5. Refit the temperature stop and handle.
Reset the maximum temperature.
24
Need help? Give us a call on 0844 701 6273 and speak to one of our trained advisers.
Adjusting the Temperature
Adjusting the Temperature
The shower valve has been factory set to
42ºC with equal (balanced) hot and cold
water supply pressures, with the hot water
supply at 65ºC.
If your operating conditions are
different from those above, the outlet
water temperature may differ from the
factory setting.
If required the shower valve can be
re-calibrated to suit your own temperature
requirements.
Set the temperature control to the
maximum setting and check the
temperature of the water with a
thermometer. If the temperature is not
correct, re-calibrate the shower valve:
1. Remove the temperature handle but do
not remove the plastic temperature stop.
2. Turn the spline clockwise to decrease
the temperature and anti-clockwise to
increase the temperature. Check the
temperature and adjust until you achieve
the required temperature.
3. Replace the temperature handle
ensuring it is fitted back into the
maximum position.
Temperature
Stop
(Do not remove)
Hotter
Colder
Spline
Need help? Give us a call on 0844 701 6273 and speak to one of our trained advisers.
25
Troubleshooting
Symptom
Cause
Remedy
No flow or low
flow rate and
/ or varying
temperatures.
Check showerhead, hose and
filters for any blockage.
Clean as necessary, refer to
Maintenance section (page 24).
Partially closed stop or service
valve in water supply pipework
to the shower valve.
Open stop or service valve.
Instantaneous water heater
cycles on and off as the flow
rate or pressure is too low.
Increase water flow rate or
pressure through system.
Head of water is below the
minimum distance required.
Raise the cistern or fit a shower
booster pump.
Inlet filter is partially blocked.
Clean or replace, flush through
pipework before refitting.
Hot or cold water being drawn
off elsewhere causing pressure
changes or instantaneous
boiler temperature changes.
Do not use other water outlets
when using the shower.
Make sure the maintained
inlet pressures are nominally
balanced and sufficient.
Refer to Specification (page 6).
Airlock or partial blockage of
the pipework.
Flush through pipework to ensure
removal of debris and any airlocks.
No hot or cold water reaching
the shower valve.
Check hot and cold feeds (the
valve will shut down if either the
hot or cold supply fails).
Partially closed stop or service
valve in water supply pipework
to the shower valve.
Open stop or service valve.
Inlet filter is partially blocked.
Clean or replace, flush through
pipework before refitting.
Inlet water supplies are
reversed (hot to cold supply).
Check the connections are the
correct way round. Hot on the
left and cold on the right when
viewed from the front. Rework
pipework as necessary.
Only hot or cold
water from the
shower valve
outlet.
26
Contact the boiler manufacturer.
Need help? Give us a call on 0844 701 6273 and speak to one of our trained advisers.
Troubleshooting
Symptom
Cause
Remedy
Maximum water
temperature too
hot or cold.
Maximum water temperature
set incorrectly.
Reset maximum water
temperature. Refer to ‘Maximum
Temperature setting’ in
Maintenance section (page 24)
and ‘Adjusting the Temperature’
(page 25)
Outlet water
temperature too
hot / cold.
Inlet filter is partially blocked.
Check inlet filters for any
blockages and clean as
necessary.
Installation conditions outside
operating parameters.
Refer to Specification (page 6).
Service shower valve as
recommended. Refer to
Maintenance section (page 24).
Refer to ‘Adjusting the
Temperature’ section (page 25).
Water
temperature
too cold Maximum water
temperature
incorrectly set.
Hot water temperature is less
than 10ºC above the required
blend temperature.
Adjust hot water temperature or
wait for water to reheat if stored
system is used.
Instantaneous water heater
not igniting because water flow
rate is too low.
Increase water flow rate through
the system.
Check inlet filters and clean or
replace. Refer to Maintenance
section (page 24).
Contact the boiler manufacturer.
Need help? Give us a call on 0844 701 6273 and speak to one of our trained advisers.
27
Notes
Please use this space to add any notes you or your installer may have regarding the
plumbing system / installation of this product.
28
Need help? Give us a call on 0844 701 6273 and speak to one of our trained advisers.
Notes
Please use this space to add any notes you or your installer may have regarding the
plumbing system / installation of this product.
Need help? Give us a call on 0844 701 6273 and speak to one of our trained advisers.
29
Guarantee
At Bristan, we want to make things as
easy as possible for our customers. That’s
why we design products that are easy to
fit and use, and that are quality tested to
make sure they won’t let you down. It’s
also why we offer solid guarantees on all
products, effective from the date of
purchase, to give you peace of mind.
Bristan’s shower valves are covered by a 5
year guarantee. This also includes 5 years
labour cover * (subject to registration)
which means that, in the unlikely event
that there is a problem in the first year
after purchase, we’ll send one of our
expert engineers to fix it.
*Labour is provided by an approved
Bristan Care engineer or appointed
representative. The guarantee only applies
to products with a manufacturing fault.
There will be a call out charge for any
incidents where no fault has been found
with the product, or if the issue is due to
poor installation or maintenance.
Guarantee Terms and Conditions
This guarantee is in addition to your
statutory and other legal rights and is
subject to the following conditions:
• The product was purchased within
the United Kingdom or Republic of
Ireland.
• The guarantee applies solely to the
original purchaser with proof of
purchase.
• The installation must allow ready access
to all products for the purpose of
inspection, maintenance or replacement.
30
• Repair under this guarantee does not
extend the original expiry date. The
guarantee on any replacement parts or
product ends at the original expiry date.
• Any part found to be defective during
the guarantee period will be replaced
without charge, providing that the product
has been installed in accorance
with the instructions given in this guide
and used as the manufacturer intended.
The guarantee does not cover:
• Damage or defects caused by;
- General wear and tear (including
special non-chrome finishes;
components such as filters, seals, ‘O’
rings and washers)
- Incorrect installation
- Repair using non-Bristan parts
- Accidental or wilful misuse
- Corrosion and the use of
inappropriate cleaning products
- System debris including the build
up of limescale (which can be
controlled through regular servicing
and maintenance)
• Compensation for loss of use of the
product or consequential loss of any
kind.
In the interests of continuous product
improvement, Bristan reserves the right to
alter product specifications without notice.
The Bristan Product Guarantee does not
affect your statutory rights as a consumer.
Need help? Give us a call on 0844 701 6273 and speak to one of our trained advisers.
Guarantee
• Need help?
If this product does not function correctly
when first used, contact Bristan Care
Customer Service on 0844 701 6273
where our expert team of advisors will be
able to offer you help and advice.
Spare parts
We hold thousands of spares and we keep
them for discontinued products for over
seven years. Spares can easily be ordered
online at www.bristan.com and are
dispatched the same day.
• Problems during the guarantee period
In the unlikely event that you encounter
any problems with the product during the
guarantee period, contact Bristan Care
Customer Service on 0844 701 6273 with
your proof of purchase and we will work to
resolve the problem quickly.
Expert plumbing engineers
If we can’t solve the problem over the
‘phone or with a spare part, then we’ll
send out one of our Bristan Care
engineers to take a look. Bristan Care
engineers provide free support for
products that are within guarantee, but
are also available to service products that
are out of guarantee for a small charge.
For details, please call Bristan Care
Customer Service on 0844 701 6273.
Bristan Care Customer Support
Bristan customers also benefit from the
support of Bristan Care, our
comprehensive customer support package
which offers:
Technical support hotline
(Tel: 0844 701 6273) with access to fully
trained advisers who can offer installation
advice, talk you through quick
maintenance checks, or recommend the
best course of action to fix any problems
with a product.
Expert advice
Find easy to follow ‘how to’ video guides
and technical FAQs online at
www.bristan.com. Our guides take you
step-by-step through many product
installations and you can find plenty of
easy guides to quick product fixes and
servicing.
Need help? Give us a call on 0844 701 6273 and speak to one of our trained advisers.
31
Part Number: FI: SHC3DIV
Issue: D4
Useful contact details:
Bristan Group Ltd,
Birch Coppice Business Park
Dordon
Tamworth
Staffordshire
B78 1SG
Web: www.bristan.com
Email: enquire@bristan.com
A Masco Company
Customer Service:
0844 7016273
Customer Service Email:
Customercare@bristan.com
Customer Service Fax:
0844 7016275
Reception:
0844 7016274
Join us on...
CAS KIT03 C
Step 2
Step 1
Step 6
Step 3
Step 7
Step 4
Step 5
Step 8
Slider operation
Download PDF
Similar pages