L P & N A T U R A L G A S
G E N E R A T I N G S E T
Exclusively from your Caterpillar® dealer
GEUG16-1
50 HZ
STANDBY
PRIME
60 HZ
STANDBY
PRIME
16.5 kVA
14.0 kVA
20.0 kVA
16.9 kVA
Ratings applicable for LP Gas.
See page 4 for Natural Gas ratings
FEATURES
GENERATING SET
● Complete
system designed and built at ISO9001
certified facility
● Factory tested to design specifications at full load
conditions
● Fully engineered with a range of options and
accessories
ENGINE
● Industrial
water cooled natural gas engine
● Governor, electronic
● Electrical system, 12 VDC
● Cartridge type fuel and oil filters
● Air filter
● Battery(ies), rack and cables
● Gas shutoff valve, solenoid operated
● Gas pressure regulator
● Low oil pressure shutdown
COOLING SYSTEM
● Standard
ambient temperatures up to 43° C (110° F)
fan drive and charging alternator fully guarded
● Antifreeze protection coolant
● High coolant temperature shutdown
● Low coolant level shutdown
● Low coolant temperature alarm
● Fan,
CIRCUIT BREAKER
● 3-pole
miniature circuit breaker (mcb)
isolated sheet steel enclosure
● Outgoing cable stub up area directly below circuit
breaker
● Vibration
AUTOMATIC VOLTAGE REGULATOR
● Voltage
regulation 0.5 %
fast recovery from transient load changes
● Provides
EQUIPMENT FINISH
GENERATOR
● All
● Self
● Anticorrosive
excited brushless generator
● Insulation system, class H
● Drip proof generator air intake (IP23)
● Electrical design in accordance with BS5000 Part 99,
IEC60034-1, VDE0530
CONTROL SYSTEM
● 2001K Autostart
control panel
● Vibration isolated sheet steel enclosure with hinged
lockable door
electroplated hardware
paint protection
● High gloss polyurethane paint for durability and scuff
resistance
QUALITY STANDARDS
● BS4999,
BS5000, BSEN60034, BSEN61000, IEC60034
DOCUMENTATION
● Operation
● Wiring
and maintenance manuals provided
diagrams included
MOUNTING ARRANGEMENT
WARRANTY
● Heavy-duty
● All
fabricated steel base with lifting points
pads to ensure vibration isolation
● Engine coupled to generator with flexible disc
coupling
● Coolant and lube oil drains piped to edge of base
● Anti-vibration
LEHF1340-06 (02/07)
equipment carries full manufacturer's warranty
5 0
H z
6 0
H z
S
P
S
P
T
R
T
R
A
I
A
I
N
M
N
M
D B Y
E
D B Y
E
1
1
2
1
6
4
0
6
.
.
.
.
5
0
0
9
k
k
k
k
V
V
V
V
A
A
A
A
Exclusively from your Caterpillar® dealer
OPTIONAL EQUIPMENT*
Anti-condensation heater
Coolant heater
Radiator transition flange
Fuel System
Low coolant temperature alarm
Low gas pressure alarm
Gas installation kit
Silencer System — Open Unit
Level 2 silencer system (25 dB(A))
Level 3 silencer system (35 dB(A))
Mounting kit
Through wall installation kits
Enclosures
Sound attenuated enclosure (includes internal silencer system)
Circuit Breaker
Upgrades from 3-pole to 4-pole breaker
Earth leakage protection, CB trip
Transfer Switches
TM Series manual transfer switches
TC Series compact automatic transfer switches
ATI Series intelligent automatic transfer switches
Certification
European CE certification (not available on 60 Hz models)
*Some options may not be available on all models.
Not all options are listed.
Generator
Cooling System
Consult your Olympian representative for more information
LEHF1340-06 (02/07)
2
5 0
H z
6 0
H z
S
P
S
P
T
R
T
R
A
I
A
I
N
M
N
M
D B Y
E
D B Y
E
1
1
2
1
6
4
0
6
.
.
.
.
5
0
0
9
k
k
k
k
V A
V A
W
W
Exclusively from your Caterpillar® dealer
SPECIFICATIONS
Piston speed — m/sec (ft/sec)
50 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.1 (13.5)
60 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.9 (16.1)
Maximum power at rated rpm — kW (hp)
Standby
LP
Natural
50 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . 15.0 (20.1) 13.7 (18.4)
60 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . 18.4 (24.8) 17.4 (23.4)
Prime
50 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.8 (17.2)
11.5 (15.4)
60 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . 15.8 (21.1) 15.8 (21.1)
BMEP — kPa (psi)
Standby
50 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 668 (96.9)
60 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 685 (99.3)
Prime
50 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 570 (82.7)
60 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 584 (84.6)
Governor
Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electronic
Class . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ISO 8528 G2
GENERATOR
Make . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Olympian
Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LUA1014NX
Type . . . . . . . . . . . . . . . . . . . . Brushless, self excited, self regulated
Voltage regulation . . . . . . . . . . . . . . . . . . . . . . ±0.5% at steady state
from no load to full load
Frequency . . . . . . . . . . . . . . . . . . . . . ±0.25% for constant load from
no load to full load
Waveform distortion . . . . . . . . . . . THD less than <4%, at no load
Radio interference . . . . . . . . . . . . . . . Compliance with EN61000-6
Telephone Interference . . . . . . . . . . . . . . . . . . . . . . TIF <50, THF <2%
Overspeed limit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2250 rpm
Insulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Class H
Temperature rise . . . . . . . . . . . . . . . . . . . . . . . . Within Class H limits
Deration . . . . . . . . . . . . . . . . . Consult factory for available outputs
ENGINE
Manufacturer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HM
Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.8L
Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-Cycle
Aspiration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Natural
Cylinder configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 in line
Displacement — L (cu in) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.82 (111)
Bore/stroke — mm (in) . . . . . . . . . . . . . . . . . . . . . . 84.0/82.0 (3.3/3.2)
Compression ratio . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.5:1
Engine speed — rpm
50 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1500
60 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1800
GENERATING SET DIMENSIONS AND WEIGHTS
Length
mm (in)
Width
mm (in)
Height
mm (in)
Weight*
kg (lb)
1348 (53.1)
710 (28.0)
1004 (39.6)
405 (891)
Model
GEUG16-1
Note:- General configuration not to be
used for installation. See general
dimension drawings for detail.
*Includes oil and coolant
Consult your Olympian representative for more information
LEHF1340-06 (02/07)
3
5 0
H z
6 0
H z
S
P
S
P
T
R
T
R
A
I
A
I
N
M
N
M
D B Y
E
D B Y
E
1
1
2
1
6
4
0
6
.
.
.
.
5
0
0
9
k
k
k
k
V
V
V
V
A
A
A
A
Exclusively from your Caterpillar® dealer
GEUG16-1 (3-Phase) 50 Hz
LP Gas
Generator Set Technical Data
Package Performance
Power rating
Lubricating System
Type: Full pressure
Oil filter: Spin-on, full flow
Oil type required: API CF-4
Total lube system capacity
Oil pan capacity
Fuel System
Generator set fuel consumption
100% load
75% load
50% load
kVA (kW)
L (U.S. Gal)
L (U.S. Gal)
m3/hr (cfh)
m3/hr (cfh)
m3/hr (cfh)
Engine Electrical System
Ignition system: Electronic, Distributorless
Voltage/ground: 12 vDC/negative
Battery charging alternator ampere rating
Cooling System
Water pump type: Centrifugal
Cooling system capacity
Maximum coolant static head
Coolant flow rate
Minimum temperature to engine
Temperature rise across engine
Heat rejected to coolant at rated power
Total heat radiated to room at rated power
Radiator fan load
Air Requirements
Combustion air flow
Maximum air cleaner restriction
Radiator cooling air
Generator cooling air
External restriction to cooling airflow
Exhaust System
Maximum allowable backpressure
Exhaust flow at rated power
Exhaust temperature at rated power
(dry exhaust)
Generator Set Noise Rating*
(without attenuation) at 1 m (3.28 ft)
Natural Gas
Standby
Prime
Standby
Prime
16.5 (13.2)
14.0 (11.2)
15.0 (12.0)
12.5 (10.0)
4.5 (1.18)
4.0 (1.05)
2.2 (76.9)
1.6 (58.2)
1.1 (40.6)
1.9 (65.5)
1.4 (49.8)
1.0 (34.8)
4.5 (1.18)
4.0 (1.05)
5.1 (180)
3.9 (137)
2.7 (95.3)
4.3 (151)
3.3 (116)
2.3 (80.5)
amps
45
45
L (U.S. Gal)
m H2O (ft H2O)
L/hr (U.S. gal/hr)
°C (°F)
°C (°F)
kW (Btu/min)
kW (Btu/min)
kW (hp)
6.1 (1.61)
2.0 (6.5)
2280 (602)
76.0 (169)
2.90 (5.22)
14.1 (804)
12.1 (685)
7.46 (424)
6.4 (362)
0.50 (0.67)
0.50 (0.67)
6.1 (1.61)
2.0 (6.5)
2280 (602)
76.0 (169)
3.10 (5.58)
12.9 (734)
10.8 (614)
6.8 (387)
5.7 (324)
0.50 (0.67)
0.50 (0.67)
m3/min (cfm)
kPa (in H2O)
m3/min (cfm)
m3/min (cfm)
Pa (in H2O)
1.31 (46.4)
1.12 (39.4)
1.5 (6.0)
63.0 (2225)
9.0 (318)
247 (1.0)
1.14 (40.2)
0.95 (33.5)
1.5 (6.0)
63.0 (2225)
9.0 (318)
247 (1.0)
kPa (in Hg)
m3/min (cfm)
17.3 (5.12)
3.87 (137)
3.23 (114)
17.3 (5.12)
3.57 (126)
2.90 (102)
568 (1054)
580 (1076)
°C (°F)
dBA
552 (1026)
TBA
557 (1035)
TBA
**dBA levels are for guidance only
50 Hz
Generator Technical Data
Motor Starting Capability:
Self Excited
(kVA)
Full Load Efficiency
Standby %
Prime %
Reactances (per unit) Xd
X'd
Reactances
X"d
are shown
Xq
applicable to the
X"q
standby LPG rating
X2
X0
Time Constants:
380/220V
400/230V
415/240V
39.0
43.0
46.0
87.9
88.1
1.71
0.11
0.053
0.86
0.073
0.063
0.005
t'd
25 ms
87.9
88.1
1.55
0.09
0.047
0.77
0.066
0.057
0.004
87.8
88.0
1.44
0.09
0.044
0.72
0.061
0.053
0.004
t"
2.5 ms
t'do
409 ms
Consult your Olympian representative for more information
LEHF1340-06 (02/07)
4
ta
4 ms
5 0
H z
6 0
H z
S
P
S
P
T
R
T
R
A
I
A
I
N
M
N
M
D B Y
E
D B Y
E
1
1
2
1
6
4
0
6
.
.
.
.
5
0
0
9
k
k
k
k
V
V
V
V
A
A
A
A
Exclusively from your Caterpillar® dealer
GEUG16-1 (3-Phase) 60 Hz
LP Gas
Generator Set Technical Data
Package Performance
Power rating
Lubricating System
Type: Full pressure
Oil filter: Spin-on, full flow
Oil type required: API CF-4
Total lube system capacity
Oil pan capacity
Fuel System
Generator set fuel consumption
100% load
75% load
50% load
kVA (kW)
L (U.S. Gal)
L (U.S. Gal)
Prime
Standby
Prime
20.0 (16.0)
16.9 (13.5)
18.8 (15.0)
16.9 (13.5)
4.5 (1.18)
4.0 (1.05)
m3/hr (cfh)
m3/hr (cfh)
m3/hr (cfh)
Engine Electrical System
Ignition system: Electronic, Distributorless
Voltage/ground: 12 vDC/negative
Battery charging alternator ampere rating
Cooling System
Water pump type: Centrifugal
Cooling system capacity
Maximum coolant static head
Coolant flow rate
Minimum temperature to engine
Temperature rise across engine
Heat rejected to coolant at rated power
Total heat radiated to room at rated power
Radiator fan load
Air Requirements
Combustion air flow
Maximum air cleaner restriction
Radiator cooling air
Generator cooling air
External restriction to cooling airflow
Exhaust System
Maximum allowable backpressure
Exhaust flow at rated power
Exhaust temperature at rated power
(dry exhaust)
Generator Set Noise Rating*
(without attenuation) at 1 m (3.28 ft)
Natural Gas
Standby
2.6 (91.2)
1.9 (68.8)
1.4 (47.8)
2.2 (77.4)
1.7 (58.9)
1.2 (41.1)
45
L (U.S. Gal)
m H2O (ft H2O)
L/hr (U.S. gal/hr)
°C (°F)
°C (°F)
kW (Btu/min)
kW (Btu/min)
kW (hp)
6.1 (1.61)
2.7 (8.9)
2700 (713)
76 (169)
2.8 (5.04)
2.5 (4.5)
17.1 (970)
14.6 (827)
9.0 (512)
7.7 (436)
0.9 (1.2)
0.9 (1.2)
6.1 (1.61)
2.7 (8.9)
2700 (713)
76 (169)
2.5 (4.5)
2.5 (4.5)
16.1 (915)
14.6 (827)
8.5 (483)
7.7 (436)
0.9 (1.2)
0.9 (1.2)
m3/min (cfm)
kPa (in H2O)
m3/min (cfm)
m3/min (cfm)
Pa (in H2O)
1.58 (55.7)
1.33 (47.1)
1.5 (6.0)
75.6 (2670)
10.8 (382)
247 (1.0)
1.14 (40.2)
1.51 (53.3)
1.5 (6.0)
75.6 (2670)
10.8 (382)
247 (1.0)
kPa (in Hg)
m3/min (cfm)
17.3 (5.12)
4.83 (170)
4.00 (141)
17.3 (5.12)
4.89 (173)
4.36 (154)
600 (1112)
612 (1134)
°C (°F)
dBA
584 (1083)
TBA
60 Hz
Reactances (per unit)
Reactances
are shown
applicable to the
standby LPG rating
Time
Constants:
43.0
88.3
88.6
Xd
X'd
X"d
Xq
X"q
X2
X0
t'd
25 ms
tba
tba
tba
tba
tba
tba
tba
t"
2.5 ms
t'do
409 ms
ta
4 ms
Consult your Olympian representative for more information
LEHF1340-06 (02/07)
5.6 (198)
4.3 (151)
3.0 (105)
45
220/127V
Motor Starting Capability:
Self Excited
(kVA)
Full Load Efficiency
Standby %
Prime %
6.3 (221)
4.7 (167)
3.3 (116)
amps
**dBA levels are for guidance only
Generator Technical Data
4.5 (1.18)
4.0 (1.05)
5
605 (1121)
TBA
5 0
H z
6 0
H z
S
P
S
P
T
R
T
R
A
I
A
I
N
M
N
M
D B Y
E
D B Y
E
1
1
2
1
6
4
0
6
.
.
.
.
5
0
0
9
k
k
k
k
V
V
V
V
A
A
A
A
Exclusively from your Caterpillar® dealer
RATINGS AT AVAILABLE VOLTAGES
50 Hz
Standby - kVA (kW)
Prime - kVA (kW)
Voltage
Code
Voltage
LP
Natural
LP
Natural
VOPT502
415/240
16.5 (13.2)
15.0 (12.0)
14.0 (11.2)
12.5 (10.0)
VOPT503
400/230
16.5 (13.2)
15.0 (12.0)
14.0 (11.2)
12.5 (10.0)
VOPT504
380/220
16.5 (13.2)
15.0 (12.0)
14.0 (11.2)
12.5 (10.0)
60 Hz
Standby - kVA (kW)
Prime - kVA (kW)
Voltage
Code
Voltage
LP
Natural
LP
Natural
VOPT608
220/127
20.0 (16.0)
18.8 (15.0)
16.9 (13.5)
16.9 (13.5)
Ratings at 27° C (80° F), 152.4 m (500 ft), 60% humidity, 0.8 pf
RATING DEFINITIONS
STANDBY
These ratings are applicable for supplying
continuous electrical power (at variable load) in
the event of a utility power failure. No overload
is permitted on these ratings. When used
at standby rating the alternator will be peak
continuous rated (as defined in ISO8528-3).
Market: International
LEHF1340-05 (02/07)
278-687
PRIME POWER
These ratings are applicable for supplying
continuous power (at variable load) in lieu of
commercially purchased power. There is no
limitation to the annual hours of operation and
this model can supply 10% overload power for
1 hour in 12 hours.
Information contained in this publication may be considered confidential.
www.CAT-ElectricPower.com
Discretion is recommended when distributing.
Materials and specifications are subject to change without notice.
© 2007 Caterpillar
CAT, CATERPILLAR, their respective logos and "Caterpillar Yellow", as well as corporate and product
All rights reserved.
identity used herein, are trademarks of Caterpillar and may not be used without permission.
Printed in U.S.A.
Download PDF